PULL STATION SERIES DIE-CAST METAL MANUAL PULL STATIONS

Size: px
Start display at page:

Download "PULL STATION SERIES DIE-CAST METAL MANUAL PULL STATIONS"

Transcription

1 PULL STATION SERIES DIE-CAST METAL MANUAL PULL STATIONS UL and cul Listed, FM Approved, CSFM Listed, MEA Approved, ADA Compliant Single or Dual Action Terminal connectors 10 Amp Snap Action Switch Gold plated SPST contacts Optional auxiliary contacts Mounts on standard single gangbox Surface backboxes available High-gloss red enamel finish Glass breakrod Made in the U.S.A. Description The Potter Pull Station Series offers a complete line of die-cast pull stations for a variety of applications focusing mainly on fire alarm systems. The pull stations are available in single or dual action models. All of the pull stations have a 10-amp snap action switch and a dedicated terminal block for the ease of wire connections. All of the metal is completely coated to inhibit corrosion and provide for a uniform and quality finish. The standard models have a hex key reset, however a key reset is also available. The models are available with shallow and deep surface mount back boxes, nine different colors, and two different plating materials, as well as a weatherproof version that is rated for NEMA 4. Operation The Potter single action series of pull stations operate by pulling the white operating handle straight down and the handle will lock into place. The dual action stations require the lifting of the front cover and then pulling the white operating handle straight down. The stations are reset by opening the front and placing the handle in the normal position. Engineering Specifications The contractor shall furnish and install the Potter series of pull stations as indicated. The pull station shall be die cast construction with a "T" type pull handle that is ADA compliant. Single action pull stations shall be a P32-1T. Dual action pull stations shall be the Potter P32-1T-LP. The contact shall be a single pole, single throw switch rated at 1 amp 30V DC/125V AC. The device shall have a terminal block for ease of wiring. Once activated, the pull station shall be reset by opening the front cover. Opening of the cover in a normal state shall initiate an alarm. Specifications Switch Rating: 1 30 VDC VAC Pull Station Dimensions: 4-3/4" H x 3-1/4" W x 7/8" D Color: Red with raised white letters, white pull bar with raised red letters Optional Colors: Blue, Green, Yellow, White, Black, Gray, Purple, Orange, Chrome or Brass plated Ordering Information Type Model Number Stock Number Contact Type Nema Rating Single Action P32-1T SPST RMS-2T DPST RMS-6T DPDT Dual Action P32-1T-LP SPST Weather Proof RMS-1T-WP SPST NEMA 4 ACCESSORIES: NOTES Dual Action RMS-LP Converts single action to dual action Back Box P32-BB Surface mount back box Back Box P32-DBB Deep surface mount back box Potter Electric Signal Company, LLC 2081 Craig Road, St. Louis, MO, Phone: /Canada MKT. # REV G 2/08 PAGE 1 OF 1

2 PS-24 PHOTOELECTRIC SMOKE DETECTOR UL, ULC, and CSFM Listed, FM Approved Light Source: GaAIAs Infrared Emitting Diode Rated Voltage: VDC Working Voltage: VDC Maximum Voltage: 42 VDC Supervisory Current: 45 µa Max. at 24 VDC Surge Current: 160 µa Max. at 24 VDC Alarm Current: 150 ma Max. at 24 VDC Ambient Temperature: 32 F to 120 F (0 C to 49 C) Sensitivity Test Feature: Automatic Sensitivity window verification test. Mounting: Refer to Potter SB Series Smoke Detector Base series, bulletin no Stock number: Standard Features Low profile, 1.8 high (with base) 2 or 4 wire base compatibility, relay bases available Highly stable operation, RF/Transient protection Low standby current, 45 µa at 24 VDC Two built-in power/sensitivity supervision/alarm LED s Non-directional smoke chamber Vandal resistant security locking feature Built-in magnetic go/no go detector test feature Removable smoke labyrinth for cleaning or replacement Automatic Sensitivity window verification function meets outlined requirements in NFPA 72, Chapter 7, Inspection, Testing and Maintenance. Compatible with IS-24 ionization detectors Backwards compatible with Potter PS and IS detectors. Compatible with Potter releasing controls Operation The PS-24 photoelectric smoke detector utilizes two bi-colored LED s for indication of status. In a normal standby condition the LED s flash green every 3 seconds. When the detector senses that its sensitivity has drifted outside the UL listed sensitivity window the LED s will flash red every 3 seconds. When the detector senses smoke and goes into alarm the status LED s will latch on red. The detector utilizes an infrared LED light source and silicon photo diode receiving element in the smoke chamber. In a normal standby condition, the receiving element receives no light from the pulsing LED light source. In the event of a fire, smoke enters the detector smoke chamber and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Signals are processed and compared to a reference level, and when two consecutive signals exceeding the reference level are received within a specified period of time, the time delay circuit triggers the SCR switch to activate the alarm signal. The status LED s light continuously during the alarm period. Application The PS-24 can be used in all areas where Photoelectric Smoke Detectors are required. The wide range smoke chamber makes the PS-24 well suited for fires ranging from smoldering to flaming fires. SB Series Style bases may be used with the PS-24. Current interchangeable/ compatible devices are the IS-24 ionization detector. MKT. # REV G 8/04 PAGE 1 OF 2

3 PS-24 PHOTOELECTRIC SMOKE DETECTOR Engineering Specifications The contractor shall furnish and install where indicated on the plans, Potter Model PS-24 photoelectric smoke detectors. The combination detector head and twist-lock base shall be UL listed compatible with a UL listed fire alarm panel. The base shall permit direct interchange with Potter, PS-24H, combination photoelectric/heat detector and IS-24 ionization type smoke detector. The base shall be appropriate twist-lock base SB Series. In the event of partial or complete retrofit, the PS-24 may be used in conjunction with, or as a replacement for, Potter detectors (PS-24, PS-24H and the IS-24) the SB base applications. The smoke detector shall have two flashing status LED s for visual supervision. When the detector is in standby condition the LED s will flash green. When the detector is outside the UL listed sensitivity window the LED s will flash red. When the detector is actuated, the flashing LED s will latch on red. The detector may be reset by actuating the control panel reset switch. The sensitivity of the detector shall be capable of being measured. It shall be possible to perform a functional test of the detector without the need of generating smoke. The sensitivity of the detector shall be monitored automatically and continuously to verify that it is operating within the listed sensitivity range. To facilitate installation, the detector shall be non-polarized. Voltage and RF transient suppression techniques shall be employed to minimize false alarm potential. Auxiliary SPDT relays shall be installed where indicated. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required. Specifications subject to change without notice. PS-24 Sensitivity Test Feature The PS-24 Photoelectric Smoke Detector has a built-in automatic sensitivity test feature. 1. In normal condition, both LED s flash green. 2. When the sensitivity drifts outside of its sensitivity limits, both LED s flash red. 3. In the alarm state both LED s are red continuously. 4. When the sensitivity drifts outside of its sensitivity limits and both LED s flash red, the device needs to be cleaned or returned to the factory for cleaning. MKT. # REV G 8/04 PAGE 2 OF 2

4 PS-24H PHOTOELECTRIC/HEAT SMOKE DETECTOR Stock number: (Base sold separately) PS-24H Product Specifications UL and ULC Listed Heat Detector: 135 F Latching Light Source: GaA1 as infrared emitting diode Rated Voltage: VDC Maximum Allowable Voltage: 42 VDC Supervisory Current: 45µA Max. at 24 VDC Surge Current: 160mA Max. at 24 VDC Alarm Current: 150mA Max. at 24 VDC Ambient Temperature: 32 F F (0 C - 49 C) Test Feature: Automatic Sensitivity window verification test Service Use: National Fire Alarm Code NFPA-72 Mounting: Refer to Potter SB Series Smoke Detector Base series, bulletin no Standard Features Low profile, 2.2" high (with base) 2 or 4 wire base compatibility, relay bases available 135 F latching heat sensor Heat sensor protected by a built-in guard Highly stable operation, RF/Transient protection Low standby current, 45µA at 24 VDC Two built-in power/sensitivity supervision/alarm LEDs Non-directional smoke chamber Vandal resistant security locking feature Removable smoke labyrinth cleaning or replacement Automatic sensitivity window verification function meets outlined requirements in NFPA 72, Chapter 2&7, for inspection, Testing and Maintenance. Application The PS-24H can be used in all areas where Photoelectric Smoke Detectors are required. The wide range smoke chamber makes the PS-24H well suited for fires ranging from smoldering to flaming fires. SB Series bases may be used with the PS-24H. Current interchangeable/ compatible devices are the IS-24 Ionization detector, PS-24 photoelectric detector. Operation The PS-24H photoelectric smoke detector utilizes two bicolored LEDs for indication of status. In a normal standby condition, the LEDs flash green every 3 seconds. When the detector senses that its sensitivity has drifted outside its UL listed sensitivity window, the LEDs will flash Red every 3 seconds. When the detector senses smoke and goes into alarm, the status LED will latch on Red. The detector utilizes an infrared LED light source and silicon photo diode receiving element in the smoke chamber. During a normal standby condition, the receiving element receives no light from the pulsing LED light source. In the event of a fire, smoke enters the detector smoke chamber and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Signals are processed and compared to a reference level. And when two executive signals exceeding the reference level are received within a specified period of time, the time delay circuit triggers the SCR switch and the LED's light continuously during the alarm period. MKT. # REV K 8/04 PAGE 1 OF 2

5 PS-24H PHOTOELECTRIC/HEAT SMOKE DETECTOR Engineering Specifications The contractor shall furnish and install where indicated on the plans, Potter Model PS-24H photoelectric smoke detectors. The combination detector head and twist-lock base shall be UL listed compatible with a UL listed fire alarm panel. The base shall permit direct interchange with Potter PS-24 photoelectric detector and IS-24 ionization type smoke detector. The base shall be appropriate twist-lock base SB Series. In the event of partial or complete retrofit, the PS- 24 may be used in conjunction with, or as a replacement for, Potter detectors (PS-24, PS-24H and the IS-24) on SB Series base applications. The smoke detector shall have two flashing status LEDs for visual supervision. When the detector is in standby condition the LEDs will flash Green. When the detector is outside the UL listed sensitivity window the LEDs will flash Red. When the detector is actuated, the flashing LEDs will latch on Red. The detector may be reset by actuating the control panel reset switch. The sensitivity of the detector shall be capable of being measured. It shall be possible to per-form a functional test of the detector without the need of generating smoke. The sensitivity of the detector shall be monitored automatically and continuously to verify that it is operating within the listed sensitivity range. To facilitate installation, the detector shall be non-polarized. Voltage and RF transient suppression techniques shall be employed to minimize false alarm potential. Auxiliary SPDT relays shall be installed where indicated. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be fieldremovable when not required. Voltage and R/F transient suppression techniques shall be employed to minimize false alarm potential. Specifications subject to change without notice. SLR-24H Sensitivity Test Feature The SLR-24H Photoelectric Smoke Detector has a built-in automatic sensitivity test feature. 1. In normal condition, both LEDs flash green. 2. When the sensitivity drifts outside of its sensitivity limits, both LEDs flash red. 3. In the alarm state, both LEDs are red continuously. 4. When the sensitivity drifts outside of its sensitivity limits and both LEDs flash red, the device needs to be cleaned or returned to the factory for cleaning. 4-WIRE OPERATION INITIATING CIRCUIT LISTED END-OF-LINE DEVICE UL LISTED POWER SUPPLY 24 VDC LISTED END-OF-LINE RELAY EOLR-24 SB4-43R SB4-43R SB4-43R CONTACTS H1 H2 2-WIRE OPERATION YEL PUR ORN UL LISTED CONTROL PANEL LISTED END-OF-LINE DEVICE PANEL POWER SUPPLY NEGATIVE SB SERIES ANNUNCIATION DEVICE MUST BE CURRENT LIMITED TO 20 ma AT 24 VDC MAXIMUM. NOT LIMITING CURRENT COULD RESULT IN DAMAGE TO THE DETECTOR OR CAUSE A NO ALARM CONDITION. RESISTOR SHOWN FOR EXAMPLE ONLY. NOT ALL ANNUNCIATORS HAVE A LINE RESISTANCE. SB SERIES DWG# MKT. # REV K 8/04 PAGE 2 OF 2

6 IS-24 IONIZATION SMOKE DETECTOR UL, ULC, CSFM Listed, FM Approved Radioactive Source: AM µci Rated Voltage: VDC Working Voltage: VDC Maximum Voltage: 42 VDC Supervisory Current: 40 µa at 24 VDC Surge Current: 200 µa at 24 VDC Alarm Current: 150 ma at 24 VDC Ambient Temperature: 32 F to 120 F (0 C to 49 C) Sensitivity Test: Magnetically activated dual reed switch test Mounting: Refer to Potter SB Series Smoke Detector Base Series, bulletin no IS-24 Stock No Standard Features Low profile, 1.8" high (with base) 2 or 4 wire base compatibility, relay bases available Highly stable operation, RF/Transient protection Low standby current, 40 µa at 24 VDC Two built-in power/alarm LED's for 360 viewing Non-directional smoke chamber Vandal resistant security locking feature Built-in magnetic detector sensitivity test feature. Meets NFPA 72, Chapter 7, Inspection, Testing and Maintenance requirements Compatible with PS-24 photoelectric detectors Backwards compatible with Potter PS and IS smoke detectors. Compatible with Potter releasing controls Operation The IS-24 ionization smoke detector utilizes two bi-colored LED's for status indication purposes. In a normal standby condition the LED's flash green approximately once each second. When the detector senses smoke and goes into alarm the status LED's will latch on red. A single radioactive source of Americium-241 ionizes two chambers within the detector, a reference chamber and the smoke sensing chamber. The air is ionized by this source and a small DC current flows between the electrodes of each chamber. Smoke can freely enter the sensing chamber, while the inner chamber is virtually sealed to smoke. Smoke entering the sensing chamber causes a reduction in the DC current flow, the voltage imbalance between the two chambers is proportional to the smoke density. When the voltage difference becomes great enough it causes the detector to go into alarm. The two chamber design is utilized to compensate for changes in atmospheric and enviromental conditions. Application The IS-24 can be used in all areas where Ionization Smoke Detectors are required. The responsive, yet highly stable operation allows the IS-24 to fit in a wide range of uses. The IS-24 can be used in areas where early warning of superheated or flaming combustibles is expected. SB Series style bases may be used with the IS-24. The only current compatible device is the PS-24 Photoelectric detector. MKT. # REV G 8/04 PAGE 1 OF 2

7 IS-24 IONIZATION SMOKE DETECTOR Engineering Specifications The contractor shall furnish and install where indicated on the plans, Potter Model IS-24 ionization smoke detectors. The combination detector head and twist -lock base shall be UL listed compatible with a UL listed fire alarm panel. The base shall permit direct interchange with Potter PS-24 photoelectric type detector and PS-24H combination photoelectric/heat detector. The base shall be appropriate twist-lock base SB Series. In the event of partial or complete retrofit, the IS-24 may be used in conjunction with, or as a replacement for, Potter detectors (PS-24, PS-24H and the IS-24) on most SB base applications. The smoke detector shall have two flashing status LED's for visual supervision. When the detector is in standby condition the LED's will flash green. When the detector is actuated, the flashing LED's will latch on red. The detector may be reset by actuating the control panel reset switch. The sensitivity of the detector shall be capable of being measured. It shall be possible to perform a functional test of the detector without the need of generating smoke. The test method shall simulate effects of products of combustion in the chamber to ensure testing of the detector electronics. To facilitate installation, the detector shall be non-polarized. Voltage and RF transient suppression techniques shall be employed to minimize false alarm potential. Auxiliary SPDT relays shall be installed where indicated. The vandal-resistant, security locking feature shall be used in those areas indicated on the drawing. The locking feature shall be field removable when not required. Specifications subject to change without notice. IS-24 Sensitivity Test Feature Test Procedure 1. With detector wired to appropriate initiating circuit or current limited power source and with normal applied power, place magnet as shown in Fig Wait at least six seconds. Detector SHOULD NOT alarm and LED should not light. 3. Place magnet on detector as shown in Fig. 2 (opposite side). 4. Wait at least six seconds. Detector SHOULD alarm. 5. If detector does alarm when magnet is positioned as in Fig. 1 or does not produce an alarm when magnet is positioned as in Fig. 2, detector is not within specified sensitivity limits and may require service. Conduct testing only under Normal Standby conditions. Abnormal or Low Power conditions may affect sensitivity. Always reset power prior to testing of next unit. DO NOT PAINT TEST DO NOT PAINT TEST FIG. 1 LED S FIG. 2 DWG# MKT. # REV G 8/04 PAGE 2 OF 2

8 SB SERIES SMOKE DETECTOR BASES UL and ULC Listed Electrical: 24VDC - Polarized Suitable for use with Potter PFC Series Controls Mounting: 3 1/4 or 4 outlet box Annunciator Output: 15mA at 24VDC Alarm Current: HSC-4R - 24 VDC - 4 WIRE BASE SB - 24 VDC SB - 81R - 24 VDC - RELAY BASE SB - 24 VDC HSB - 24 VDC Service Use: National Fire Alarm Code NFPA-72 Application The SB Series is a 6 polarized base with annunciator output featuring a current limiting resistor, and a blocking diode to enhance annunciator function. The SB Series Smoke Detector base is designed specifically for use with the Potter Smoke Detector Models IS-24, PS-24 and PS-24H. These units must be installed and maintained in accordance with all applicable NFPA standards, local codes and any authority having jurisdiction. Please refer to NFPA-72 Standards for Automatic Fire Detectors for installation guidelines, and testing procedures. These detectors will not work without power. They must be properly connected into the signal initiating device circuit of a fire control panel that is listed as being compatible by Underwriters Laboratories, Inc. These detectors will not sense fires which start where smoke does not reach the detector. Fires on other building levels, within walls, on roofs, in chimneys, or on the other side of closed doors may not be detected. Fires from explosions, improperly stored flammable liquids, escaping gas, arson or fires resulting from inadequate fire protection practices may not be detected. Smoke detectors should be tested upon completion of installation and at least semi-annually thereafter, in accordance with the section of Inspections, Tests, and Maintenance in NFPA-72. To Install the Detector: Insert the detector into the base, turn the detector clockwise until it locks, then tighten the vandal resistant allen screw. UL LISTED COMPATIBLE CONTROL PANEL IN 1 2 IN 4 3 * 15 ma MAX. OUTPUT 6 5 OPTIONAL * CURRENT LIMITED AT 24 VDC Terminal # Designation 1 Positive In 2 Positive Out 3 Negative Out 4 Negative In 5 Annunciator Out 6 Annunciator Out OUT OUT DWG# Ordering Information Model# Stock# Description Compatibility SB Smoke Base - 46mA 24vdc All Potter release panels; Not for use with PFC3000, 5000, 9000 Series panels; Check other panel manufacturer s compatibility listings. SB Smoke Base - 93mA 24vdc For use on all Potter PFC 3000, 5000 Series panels. PFC9000 series with ZA9008 module added. Not for use on Potter release panels; Check other panel manufacturer s compatibility listings. SB-81R Smoke Base W/Relay - 81mA draw For use on Potter PFC 3000 and 5000 Series; Not for use on Potter release panels Check other panel manufacturer s compatibility listings. HSC-4R Wire Smoke Base W/Relay-43mA draw For use with any panel that can provide 24VDC 4-wire resettable power. For additional 2-wire base compatibility, contact Potter Technical Support at or tech@pottersignal.com. MKT. # REV K 9/07 PAGE 1 OF 1

9 BPS SERIES DIRECT-WIRE PHOTOELECTRIC SMOKE DETECTOR Low Profile - Only 1.8" High 2 or 4 Wire Models Eggshell or White UL and ULC Listed, CSFM Approved Highly Stable Operation, RF/Transient Protection Two built-in power/sensitivity supervision/alarm LED's Non-Directional Smoke Chamber Vandal Resistant Security Locking Feature Built-in magnetic go/no go detector test feature Removable smoke labyrinth for cleaning or replacement Automatic Sensitivity window verification function meets outlined requirements in NFPA 72, Inspection, Testing and Maintenance. Application The Potter Electric BPS Series can be used in all areas where Photoelectric Smoke Detectors are required. It is suited for smoldering or flaming fires. The BPS-W are ideal for security installations. Operation The BPS Series photoelectric smoke detector utilizes two bicolored LEDs for indication of status. In a normal standby condition the LEDs flash Green every 3 seconds. When the detector senses that its sensitivity has drifted outside the UL listed sensitivity window the LEDs will flash Red every 3 seconds. When the detector senses smoke and goes into alarm the status LEDs will latch on Red. The unit is comprised of an LED light source and silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from pulsing light source. In the event of fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. The light received is converted to an electronic signal. Signals are processed in the comparator, and when two consecutive signals exceeding the basic level are received within a specific period of time, the time delay circuit triggers the SCR switch to activate the alarm signal. The Status LED lights continuously during alarm period. Ordering Information Model Stock number BPS BPS BPS-2W White BPS-4W White Specification Light Source Voltage Wave Form Alarm Current Surge Current Average Standby Current Ambient Temperature Sensitivity Test Feature Compatibility Identifier Order Codes GaAl AS Infrared LED Nominal: 12 VDC or 24 VDC Working: VDC (35.0 VDC Max) Filtered DC 15% Ripple Max. 150mA Maximum 200uA Maximum (2 wire) 38uA VDC 55uA VDC 70uA VDC 32 F F (0 C - 49 C) Automatic Sensitivity Window Verification Test HD-6 2-Wire Detector & Trim Ring Bone: BPS-2 White: BPS-2W 4-Wire Detector & Trim Ring Bone: BPS-4 White: BPS-4W PRINTED IN U.S.A. MFG. # REV E PAGE 1 OF 2 11/07

10 BPS SERIES DIRECT-WIRE PHOTOELECTRIC SMOKE DETECTOR Engineering Specifications The contractor shall furnish and install where indicated on the plans Potter Electric BPS Series baseless photoelectric smoke detectors. The detector head shall be UL listed compatible with an UL listed fire alarm panel. The smoke detector shall have flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The detector shall have a sensitivity window verification feature. The vandal resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable. It shall be possible to perform a functional test of the detector without the need of generating smoke. The method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Voltage and RF transient suppression techniques shall be employed to minimize false alarm potential. Wiring Diagrams 2-Wire Wiring Diagram UL LISTED COMPATIBLE CONTROL PANEL LISTED END-OF-LINE DEVICE 4-Wire Wiring Diagram UL LISTED CONTROL PANEL LISTED END-OF-LINE DEVICE UL LISTED POWER SUPPLY *24 VDC LISTED END-OF-LINE RELAY 12 OR 24 VDC UL LISTED POWER SUPPLY *12 VDC * USE EITHER 12 VDC OR 24 VDC. THEY CANNOT BE USED SIMULTANEOUSLY. PRINTED IN U.S.A. MFG. # REV E PAGE 2 OF 2 11/07

11 DSD CONVENTIONAL DUCT SMOKE DETECTOR Standard Features Detect and limit the spread of smoke throughout building HVAC ducts Compatible with building automation and fire alarm system Installs quickly and easily - Duct Housing Cover does not need to be removed before installation to duct Interchangeable Plug-In photoelectric or ionization heads No screens or filters to clean Cover provides magnet window and placement guide for go/no-go operational testing with out disassembly Rugged gray steel back box with clear cover Accessories - Remote power, remote alarm indication capability and remote, horn/piezo capability Meets UL 268A Requirements Duct housing is available with either a conventional photoelectric or ionization detector. Model Stock No. DSD-I DSD-P Application The Potter Electric DSD Series duct smoke detector provides early detection of smoke and products of combustion present in air moving through HVAC ducts in Commercial, Industrial and Residential applications. The DSD is designed to prevent the recirculation of smoke in areas by the air handling systems, fans and blowers. Complete systems may be shut down in the event of smoke detection. The POTTER ELECTRIC DSD-I and the DSD-P operate on 115 VAC, 24 VAC and 24 VDC. Product Description The DSD Series is designed and built to meet all local requirements, as well as the NFPA regulations regarding duct smoke detectors. Output terminals are provided for remote accessories such as a horn, strobe, remote status indicators and reset key switches or push buttons. Air sampling is accomplished by two tubes which protrude into the duct. An exhaust tube of one standard length (7.5") is supplied in the installation kit with the smoke duct unit. Once the duct width has been determined the air intake sampling tubes must be ordered. Sampling tubes are supplied in three standard lengths 2.5 ft., 5 ft. and 10 ft. and cut to size to fit the duct. Mounting the duct smoke unit is accomplished by the use of a template and 4 sheet metal screws, which are provided. Mounting can be achieved without the removal of the clear cover which is secured by 4 capture screws. The compact DSD contains 3 sets of alarm contacts, 1 set of form C contacts rated at 10 amps, 1 set of form A contacts rated at 10 amps, 1 set of form A contacts rated at 1 amp. There is also 1 set of form C 10 amp trouble contacts for monitoring detector head removal, and the failure of the input supply voltage. The pilot and alarm visual indicators provided on the front of the DSD duct unit, signal the operating status of the device. A manual test/reset switch is located along side the visual indicators. This switch can be defeated by cutting a jumper on the PCB. Duct Detector Model # DSD-I DSD-P Operating Voltage 115V AC, 24V C/DC 115V AC, 24V C/DC Detector Head Model SIJ-24DH SLR-24DH Detector Head Type Conventional Ionization Conventional Photoelectric Power 230 VAC - - Requirements Standby 115 VAC 14mA 14mA 24 VAC 20mA 20mA 24 VDC 13mA 13mA Power 230VAC - - Requirements Alarm 115 VAC 28mA 28mA 24 VAC 95mA 95mA 24 VDC 60mA 60mA Alarm Contacts 1 form "C" and 1 form "A" rated at 10 amps at 115 VAC 1 form "C" and 1 form "A" rated at 10 amps at 115 VAC Detection Loop 1 form A (1A) 1 form A (1A) Trouble Contacts 1 form "C" 1 form "C" Sensitivity Test Method Dual reed switch test Self diagnostic test Remote Indication Capability (Refer to DSD Accessories Data Sheet for Specifications) Air Velocity Ambient Temperature Humidity Housing Material Finish Dimensions Maximum Net Weight Sampling Tubes Radioactive Element Power, Alarm, Horn, Piezo, Test Power, Alarm, Horn, Piezo, Test 300 to 4000 ft./min 32 F to 120 F (0 C to 49 C) 10% to 85% Relative humidity (noncondensing) 18 G.A. steel backbox, clear plastic cover Grey paint 9 1/8"L x 7 1/4" W x 2 1/4" H 3 lbs. 2.5 ft., 5 ft., or 10 ft. DSD-I only: Americum 24I 0.5 micro-curie PRINTED IN U.S.A. MFG. # REV C PAGE 1 OF 2 12/01

12 DSD CONVENTIONAL DUCT SMOKE DETECTOR Engineering Specifications Air duct smoke detectors shall be Potter Electric DSD Series. The detectors shall be listed by Underwriters Laboratories per UL 268A. The detectors shall operate at air velocities from 300 feet per minute to 4000 feet per minute. The duct detector housings shall be of metal construction and complete mechanical installation may be performed without removal of detector cover. Visual indication of alarm and power must be provided on detector front. A manual reset switch shall be located on front of the DSD-I DSDdevice. Detector heads shall not require additional filters or screens which must be maintained. The housing shall contain a detector base which will accept photoelectric or ionization detector heads. Terminal connections shall be of the screw type and be a minimum of # 6 screw. Terminals shall be provided for remote pilot, remote alarm indication, strobe/horn and remote key switch. All wiring must comply with local codes and regulations. Wiring Diagrams DSD DSD-I DSD- DSD-I DSD- PRINTED IN U.S.A. MFG. # REV C PAGE 2 OF 2 12/01

13 MS SERIES REMOTE ACCESSORIES Product Specifications Model Stock# Description MS-RA Remote Alarm LED (Red) MS-RA/P N/S Remote Alarm LED (Red) and Pilot LED (Green) MS-RA/R Remote Alarm LED (Red) and push-button Test/Reset switch MS-RA/P/R N/S Remote Alarm LED (Red), Pilot LED (Green), and push-button Test/Reset switch MS-RA/P/T N/S Remote Trouble LED (Yellow) and Pilot LED (Green) MS-RA/FT/P N/S Remote Trouble LED (Yellow), Pilot LED (Green), and push-button Test/Reset switch MS-KA/R Remote Alarm LED (Red) and keyoperated Test/Reset switch MS-KA/P/R Remote Alarm LED (Red), Pilot LED (Green), and key-operated Test/Reset switch MS-KA/P/T N/S Remote Trouble LED (Yellow), Pilot LED (Green), and key-operated Test/Reset switch MS-RD N/S Remote Duct Smoke Detector LED (Red) MS-F/T N/S Remote Touble LED (Yellow) MS-RH/P/A N/S Remote Alarm Horn, Alarm LED (Red), and Pilot LED (Green) MS-RH/KA/P/R Remote Alarm Horn, Alarm LED (Red), Pilot LED (Green), and key-operated Test/ Reset switch MS-RH/KA/P/A/T Remote Alarm Horn, Alarm LED (Red), Trouble LED (Yellow), Pilot LED (Green), and key-operated Test/Reset switch MS-RH N/S Remote Alarm Horn * N/S = Non-Stock Item (Special Order) Product Description The MS Series remote accessories are designed to be used with the ADSD, DSD, and RW Series Duct Smoke Detectors to provide audible and visual indication as well as remote test/reset functions. These devices are constructed of brushed stainless steel and mount on a standard single or double gang electrical backbox. Power Requirements Alarm LED Pilot LED Horn Sound Pressure Horn Dimensions Single Gang Double Gang 15mA 15mA 24 VDC 10 ft. 2.75" (69.85mm) W 4.5" (114.3mm) H 4.5" (114.3mm) W 4.5" (114.3mm) H MFG. # REV B PAGE 1 OF 1 11/06

14 HEAT DETECTOR SERIES UL and ULC Listed Contact Ratings: Dimensions: 3 Amps at 125 VAC 1Amp at 28 VDC 0.3 Amps at 125 VDC 0.1 Amps at 250 VDC Diameter 5.25 (13.4cm) Height 2 (4.85cm) Weight: 0.41 lbs. (330 grams) Model CR135W Model Number Stock Number CR 135W CR 200W CF 135W CF 200W Call for other available models Description The Thermoflex product group includes standard detectors as well as detectors for hazardous locations and moisture proof applications. Each detector is available in single or multiple circuits with open and/or closed contact configurations. The prefix CR in the model number denotes rate of rise and fixed temperature operation. The prefix CF denotes fixed temperature only. The standard fixed temperature settings are 135 F and 200 F. Units set at 165 F and 285 F are also available. Model CF 135 W The CF135W is a fixed temperature only detector. The fixed temperature portion consists of a spring loaded plunger retained by a fusible alloy that releases when the ceiling temperature reaches 135 F (57 C). When released, the plunger strikes a normally open set of contacts and holds them closed. Spacing on an uninterrupted ceiling is 40 (12.5m). The CF135 is identified by a black dot on its heat collector fin. Model CR 200 W The CR200W is a combination rate of rise and fixed temperature detector that operates in the same way as the CR135W, except that the fi x e d t e m p e r a t u r e p o r t i o n r e l e a s e s w h e n t h e c e i l i n g t e m p e r a t u r e r e a c h e s 200 F (93 C) The spacing parameters for the rate of rise is 70 (22 m). The CR200W is identified by a black ring on its heat collector fin. Model CF 200 W The CF200W is a fixed temperature only detector. The fixed temperature portion releases when the ceiling temperature reaches 200 F (93 C). Spacing is 25 (7.62m). The CF200W is identified by a black dot and a black ring on the heat collector fin. Normally Closed Contacts Any detector in this series is available in normally open or normally closed contacts. The model number does not reflect the normally open configuration, however, the suffix C denotes normally closed. For example, CR135C W describes a rate of rise/fixed temperature detector, fusing at 135 F, with one set of normally closed contacts. Engineering Specifications Thermoflex Model CR135 Automatic Rate of Rise Heat Detectors shall be installed in areas where ambient temperatures do not exceed 100 F. In areas where ambient temperture is above 100 F but will not exceed 150 F, specify CR165 units. If ambient temperatures exceed 150 F, specify CR200 or CF285. In areas where sudden increases in ceiling temperature are normal, specify fixed temperature only units, with fusable settings of 135 F, 165 F, 200 F, or 285 F. The rate of rise operation responds to temperature increases of 15 F (8.4 C) per minute. Thermoflex detectors shall be installed in areas where environmental conditions including dust, vapors, insects, etc. would cause an ionization or photoelectric type detector to initiate a false alarm. All wiring must be installed in compliance with the local electrical code using approved cable, AWG 18 minimum. Begin electrical connections by stripping approximately 1 (2.5cm) from the end of each wire. Insert the stripped end into the wire retaining hole in the terminal bar, wrap clockwise around the terminal screw, and tighten. Circuit wiring must be broken at each terminal to ensure proper supervision. Potter Electric Signal Company 2081 Craig Road, St. Louis, MO, Phone: /Canada MKT. # REV N 9/07 PAGE 1 OF 1

15 SPB-24N PROJECTED BEAM SMOKE DETECTOR Microprocessor based for reliability Simple setup & alignment with signal strength LED s Provides 60 feet on center linear protection at a range of 32.8 feet to 328 feet Automatic compensation for signal drift or dirty lens Three field adjustable sensitivity settings Form A alarm and Form B trouble contacts Calibrated filters available to verify sensitivity Color-coded emitter and receiver labels for easy recognition Stock number: Application The SPB-24N Projected Beam Smoke Detector consists of an emitter and receiver. The projected beam smoke detector should be placed so that smoke generated by a fire will likely rise into the path of the beam. The receiver is constantly monitoring and measuring the intensity of the beam transmitted by the emitter. Should the smoke from a fire cause a decrease in the signal strength of a magnitude that exceeds the programmed obscuration setting, an alarm signal is generated. The SPB-24N Projected Beam Smoke Detector can provide vital fire detection in applications where other type detectors may not be able to respond quickly, or at all, to a fire condition. Examples of some applications where projected beam smoke detectors have been successfully used include: atriums, gymnasiums, theatres, museums, factories, tunnels, churches, stables,anechoic chambers and high air velocity areas. The SPB- 24N Projected Beam Smoke Detector may also be used in conjunction with more traditional spot type smoke detection devices to provide an even more comprehensive detection system. For more information on how to install the SPB-24N Projected Beam Smoke Detector consult the SPB-24N Installation Instruction Guide and the applicable NFPA Standards for additional guidance. Operation The near infrared pulsed beam generated by the emitter is sensed by the photodiode of the receiver, where it is converted into an electrical signal. This signal is then amplified and applied, via an analog to digital converter, to a microprocessor. The normal state signal (the initial beam data) once stored in the microprocessor is used as reference for comparison with subsequent beam signals. When there is a difference between actual beam strength and stored reference data that exceeds the programmed alarm obscuration reference level, a fire signal is produced. A trouble signal is generated if the beam is more than 90% obstructed (as opposed to partially obscured by smoke). The microprocessor also provides compensation for a change in received signal value, with time, caused by contamination of the optics. Since such a change with time appears as a slow change in the beam signal, the microcomputer compensates in such a manner that the signal moves closer to the reference data at a rate approximately +1% per hour. When this compensating capability reaches a limit, the microcomputer automatically generates a trouble signal. A calibrated test filter is available upon request to test and verify the sensitivity setting of the projected beam smoke detectors. Specifications Rated Voltage Working Voltage Supervisory Current Alarm Current Trouble Current Ambient Temperature Range Sensitivity Test Feature Dimensions Mounting Specifi cations subject to change without notice. 24VDC 19VDC - 33VDC 24VDC 24VDC 24VDC 32 F-122 F Manufacturers test filters 5.5" Tall 3.2" Wide 4.0" Deep Wall mount or Single Gang Box MKT. # REV D 1/03 PAGE 1 OF 2

16 SPB-24N PROJECTED BEAM SMOKE DETECTOR Engineering Specifications The contractor shall furnish and install, where indicated on the plans, the SPB-24N Projected Beam Smoke Detector. The detector shall have a range of 32.8 feet to 328 feet. The projected beam smoke detector shall be field adjustable to one of the three obscuration settings of 25%, 50% or 70% per span. These settings shall be capable of being verified with calibrated filters. Side to side spacing shall be a maximum of 60 feet on center. The projected beam smoke detector shall possess circuitry that automatically compensates for normal ambient changes in the intensity of the emitted beam strength. The microprocessor shall provide compensation for a change in received signal value, with time, caused by contamination of the optics. Since such a change with time appears as a slow change in the beam signal, the microcomputer compensates in such a manner that the signal moves closer to the reference data at a rate of approximately +1 % per hour. When this compensating capability reaches a limit, the microcomputer automatically generates a trouble signal. The projected beam smoke detector(s) shall also signal a trouble condition if the beam has a blockage of 90% or more than 20 seconds and automatically resets to normal when blockage is removed. The projected beam smoke detector(s) shall be UL listed for these applications. Voltage and RF transient protection shall be integral to the internal circuitry of the projected beam smoke detector so as to minimize false alarm potential. To facilitate easy installation and setup, the projected beam smoke detectors shall employ signal strength indicating LEDs. Alignment shall be facilitated by turning an alignment adjustment wheel and monitoring the relative signal strength based upon which LEDs are illuminated. The detectors shall also illuminate a red LED, which is visible externally, when an alarm condition is indicated. The projected beam smoke detector shall provide a Form A dry contact for alarm and Form B dry contact for trouble. Installation The SPB-24N Projected Beam Smoke Detector shall be installed in accordance with the Installation Instruction Guide provided with every unit. Refer to the applicable NFPA Standards for additional guidance on spacing, irregular ceiling surfaces and other design considerations. 4-WIRE CONNECTION TO THE CONTROL PANEL EMITTER E2 E1 EMITTER E2 E1 E2 E1 E2 24V OV F1 F2 T2 E1 EOLR-24 24V 24V ZONE ZONE CONTROL PANEL 24V OV F1 F2 T2 24V OV F1 F2 T2 24V OV F1 F2 T2 END OF LINE RESISTOR NOTE: EOLR-24 REQUIRED FOR POWER SUPERVISION. DWG# MKT. # REV D 1/03 PAGE 2 OF 2

17 PAM-1 MULTI-VOLTAGE RELAY MODULE Single SPDT relay with LED Double-sided adhesive tape Mounting screw 12" leads 6 wire nuts Stock number: Power Requirements: Per position VDC, 24VAC, 115VAC Relay: UL recognized SPDT Contact Rating: VAC 7 28VDC 250 5VDC Ambient Temperature: 32 F to 120 F (0 C to 49 C) Approvals: UL Listed Dimensions: 1.5" (38.1 mm) H x 1" (25.44 mm) W x 0.875" (22.2MM) D 12" (304.8mm) 18 ga. wire leads Product Description The PAM-1 Relay is an encapulated 24VDC multi-voltage device providing 10.0 Amp form C contacts. The relay may be energized by one of three input voltages: 24 VAC, 24 VDC, or 115 VAC. A red LED is provided which, when illuminated, indicates the relay coil is energized. The PAM-SD may be mounted by using the double-sided adhesive tape, the self-drilling screw, or loosely placed in an electrical backbox. These devices are ideal for applications where remote relays are required for control or status feedback. They are suitable for use with HVAC, temperature control, fire alarm, security, energy management, and lighting control systems. Installation Wiring RELAY ENERGIZED LED (-) N N H WHT BLK BLUE YEL C N.C. 10 AMP CONTACTS (+) C RED ORG N.O A A A MFG. # REV C PAGE 1 OF 1 9/07

18 PAM-4 24VDC POLARIZED RELAY MODULE Single SPDT relay Double-sided adhesive tape Mounting screws 5 wire-nuts Stock number: Power Requirements: Per position Amp at 24VDC, 9VDC to 40VDC Relay: UL recognized SPDT Contact Rating: 10A at 115V AC 7A at 28V DC 250 Microamps at 5 V DC Ambient Temperature: 32 F to 120 F (0 C to 49 C) Approvals: UL Listed Dimensions: 1.5" (38.1mm) H x 1" (25.4mm) W x 0.875" (22.23mm) D 10" (254mm) 18ga. wire leads Product Description The PAM-4 Relay is an encapsulated polarized device providing 10.0 Amp form C contacts. The relay may be energized by an input voltage of 9V DC to 40V DC. The input has a built-in polarizing diode. The PAM-4 may be mounted by using the double-sided adhesive tape, the self-drilling screw, or loosely placed in an electrical box. These devices are ideal for applications where remote relays are required for control or status feedback. They are suitable for use with HVAC, temperature control, fire alarm, security, energy management, and lighting control systems. Installation Wiring 24V DC AT 0.015A (18V DC TO 32V DC) (-) (+) WHT RED BLUE YEL ORG C N.C. N.O. 10 AMP CONTACTS MFG. # REV B PAGE 1 OF 1 9/07

19 MR 100, 200 SERIES MULTI VOLTAGE CONTROL RELAYS Made in Recognized Component "SNAP APART" SEAMS MR 104/T, MR 204/T (Similar) Relay may be energized from a voltage source of 18 to 35VDC/VAC, 115VAC or 230VAC. Each relay position contains a red LED which illuminates when the coil is energized. This provides a time saving convenience when checking an installed system, no metering is required. Single, dual, or triple relay modules may be "snapped apart" from standard 4 position master. For continuous duty use. Available in dust proof enclosures with LED viewing port. Track mounting hardware to facilitate installation in standard cabinets. UL recognized relays rated at 10,000,000 mechanical operations. UL Listed as Control Unit Accessory. Dimensions MR 101/T, MR 201/T: 3.25" (82.6mm) H x 2.125" (54mm) W x 1.5" (38.1mm) D MR 104/T, MR 204/T: 3.25" (82.6mm) H x 8.5" (215.0mm) x 1.5" (38.1mm) D MR 101/C, MR 201/C: 5.125" (130.2mm)H x 3.125" (79.0mm) W x 2.5" (63.5mm) MR 104/C, MR 204/C: 5.125" (130.2mm)H x 9.5" (241.3mm) W x 2.5" (63.5mm) D Product Description The MR Series Multi voltage Control Relays offer SPDT or DPDT 10 Amp resistive contacts which may be operated by one of four input control voltages. A single relay may be energized from a voltage source of 24VDC, 24VAC, 115VAC, or 230VAC by wiring to appropriate input terminals. Each relay position contains a red light emitting diode (LED) which indicates the relay coil is energized. Relays may be "snapped apart" from a standard 4 module assembly and used independently. These devices are ideal for applications where local contacts are required for system status, remote contacts for control of electrical loads and general purpose switching. They are suitable for use with HVAC, Temperature Control, Fire Alarm, Security, Energy Management, and Lighting Control systems. Power Requirements: MR 101 Position 24VDC 24VAC 115VAC 230VAC MR 201 Position 24 VAC 115VAC 230VAC Pull In Voltage: 75% of nominal voltage, 25 C Drop Out Voltage: 25% of nominal voltage, 25 C Enclosure: Backbox: 18 ga. CRS, plated with 1/2" Conduit Knockouts Cover: ABS 94VO Contact Rating: 10A 115VAC, 7A 230VAC, 7A 28VAC, N.O. 1/6 115VAC, N.C. 1/8 115VAC Ordering Information MR 101/T Single SPDT Relay with LED and track mounting hardware. (UL Recognized) MR 101/C Single SPDT Relay with LED mounted in an enclosure. (UL Listed) MR 104/T N/S 4 position SPDT Relay with LEDs and track mounting hardware. (UL Recognized) MR 104/C N/S 4 position SPDT Relay with LEDs mounted in an enclosure. (UL Listed) MR 201/T N/S Single DPDT Relay with LEDs & Track mounting hardware. (UL Recognized) MR 201/C Single DPDT Relay with LED mounted in an enclosure. (UL Listed) MR 204/T N/S 4 position DPDT Relay with LEDs & track mounted hardware. (UL Recognized) MR 204/C N/S 4 position DPDT Relay with LEDs mounted in an enclosure. (UL Recognized) *N/S = Non Stock Item (Special Order) Installation Wiring (Typical for module position) SPDT DPDT Ambient Temperature: 32 F to 120 F Approvals: MR 101/C, MR 104/C, MR 201/C, MR 204/C, U.L. Listed File #S3403, City of New York MEA #73 92 E, CSFM # :101 MR 101 (MR 104) MR 201 (MR 204) Potter Electric Signal Company 2081 Craig Road, St. Louis, MO, Phone: /Canada MFG. # REV B PAGE 1 OF 1 9/07

ALK-V PHOTOELECTRIC SMOKE SENSOR

ALK-V PHOTOELECTRIC SMOKE SENSOR ALK-V PHOTOELECTRIC SMOKE SENSOR APPLICATION The HOCHIKI America ALK-V Photoelectric Smoke Sensor is particularly suited to detecting optically dense smoke typical of fires involving materials such as

More information

PRODUCT OVERVIEW SM-501 AT-A-GLANCE

PRODUCT OVERVIEW SM-501 AT-A-GLANCE AIR PRODUCTS AND CONTROLS INC. INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR SM-501 SERIES DUCT SMOKE DETECTORS SM-501-N SM-501-P PRODUCT APPLICATION SM-501 Series duct smoke detectors provide early detection

More information

TrueAlarm Analog Sensing

TrueAlarm Analog Sensing TrueAlarm Analog Sensing UL, ULC Listed* Addressable Duct Sensor Housings with TrueAlarm Photoelectric Sensor; Available with Multiple Relay Features Compact air duct sensor housing with clear cover to

More information

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608) FORM ASX-40020 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS SL-2000 Series Smoke Detectors, Model EXSAA and EXSAB (Ionization), EXSAG and EXSAH (Photoelectric) Air Specialties Express, 448 S. Main

More information

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608) FORM ASX-40021 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS SM-501 Series Smoke Detectors, Model EXSAC and EXSAD (Ionization), EXSAJ and EXSAK (Photoelectric) Air Specialties Express, 448 S. Main

More information

You in Control PRODUCT OVERVIEW

You in Control PRODUCT OVERVIEW AIR PRODUCTS AND CONTROLS You in Control AIR PRODUCTS AND CONTROLS INC. INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR SERIES PLENUM DUCT SMOKE DETECTORS NO-FLOW LOW-FLOW SPECIAL APPLICATION -N -P PRODUCT

More information

Addressable Detectors & Bases

Addressable Detectors & Bases Edwards Signaling Catalog u Intelligent Initiating Addressable Detectors & Bases Detectors: E-PD, E-PHD, E-HD Bases: B4U, RB4U, IB4U, SB4U Overview Edwards intelligent addressable detectors are meticulously

More information

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector Wiring Instructions for the 900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector CAUTION: FAILURE TO INSTALL OR ADJUST PROPERLY MAY RESULT IN INJURY OR

More information

PRODUCT OVERVIEW. SL-2000 AT-A-GLANCE MODEL NUMBER: SL-2000-N 4-Wire Ionization Duct Smoke Detector SL-2000-P 4-Wire Photoelectric Duct Smoke Detector

PRODUCT OVERVIEW. SL-2000 AT-A-GLANCE MODEL NUMBER: SL-2000-N 4-Wire Ionization Duct Smoke Detector SL-2000-P 4-Wire Photoelectric Duct Smoke Detector AIR PRODUCTS AND CONTROLS You in Control AIR PRODUCTS AND CONTROLS INC. INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR SERIES DUCT SMOKE DETECTORS -N 4-Wire, Ionization Type -P 4-Wire, Photoelectric Type

More information

TrueAlarm Analog Sensing

TrueAlarm Analog Sensing UL, ULC Approved* TrueAlarm Analog Sensing TrueAlarm Analog Sensors Photoelectric and Heat; Standard Bases and Accessories Features TrueAlarm analog sensing provides: Digital transmission of analog sensor

More information

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906 s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones

More information

TrueAlarm Smoke Detectors

TrueAlarm Smoke Detectors UL, ULC Approved* TrueAlarm Smoke Detectors TrueAlarm Photoelectric Smoke Detector with TrueSense Smoke/Heat Detection Features detection. If any of these alarm conditions are experienced, an alarm is

More information

Installation Manual: PAD100-DUCTR Analog Addressable Duct Detector

Installation Manual: PAD100-DUCTR Analog Addressable Duct Detector Installation Manual: PAD100-DUCTR Analog Addressable Duct Detector NOTICE TO THE INSTALLER This manual provides an overview and the installation instructions for the PAD100-DUCTR module. This module is

More information

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors Hinge Edge of Door Hinge Edge of Door Wiring Instructions for the Sargent 0 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector CAUTION: FAILURE TO INSTALL

More information

Duct smoke housings, 4-wire D341/D341P and D342/D342P

Duct smoke housings, 4-wire D341/D341P and D342/D342P Duct smoke housings, 4-wire D341/D341P and D342/D342P en Installation manual Duct smoke housings, 4-wire Notices en 3 1 Notices These instructions cover the installation of the D341/D342 Duct smoke housings

More information

You in Control PRODUCT OVERVIEW SM-501 AT-A-GLANCE

You in Control PRODUCT OVERVIEW SM-501 AT-A-GLANCE AIR PRODUCTS AND CONTROLS You in Control AIR PRODUCTS AND CONTROLS INC. INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR SM-501 SERIES DUCT SMOKE DETECTORS SM-501-N 4-Wire, Ionization Type SM-501-P 4-Wire,

More information

Multi-Point Peripherals

Multi-Point Peripherals UL, ULC Approved* Multi-Point Peripherals TrueAlarm CO Sensor Bases for Smoke, Heat, and Photo/Heat Sensors using IDNet Communications Features Fig 1: TrueAlarm CO Sensor Base with Sounder (shown with

More information

SECTION FIRE ALARM SYSTEMS

SECTION FIRE ALARM SYSTEMS SECTION 16721 FIRE ALARM SYSTEMS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work

More information

Reshaping Duct Smoke Detection

Reshaping Duct Smoke Detection Reshaping Duct Smoke Detection Y TE + TEST COIL TEST COIL + IN + OUT RA + RA + RTS (+) 24 VDC AUX POWER SUPPLIED BY USER (100mA SUPPLY) 24 VAC (+10%, 15%) FULL WAVE RECTIFIED, UNFILTERED POWER MAY BE USED

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

DH100ACDCI Ionization Air Duct Smoke Detector

DH100ACDCI Ionization Air Duct Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS Ionization Air Duct Smoke Detector Before Installing Please thoroughly read the System Sensor Guide for Proper Use of Smoke Detectors in Duct Applications (A05-1004),

More information

TrueAlarm Analog Sensing

TrueAlarm Analog Sensing TrueAlarm Analog Sensing UL, ULC Listed, CSFM Approved* Features Air aspiration duct smoke detection** system provides remote sensor location for ducts with difficult service access: Available as either

More information

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature AutoTest VSR (VSR-AT) (EU) Features Assembled in USA 0-30 second field replaceable electronic retard Two SPDT (Form C) switch contacts Weatherproof Easy to read wire terminal designations Easy to read

More information

Reshaping Duct Smoke Detection

Reshaping Duct Smoke Detection Reshaping Duct Smoke Detection When System Sensor introduced the Innovair line of duct smoke detectors and accessories, it was revolutionary. Mechanical contractors and fire systems installers like you

More information

Series 65 Product Guide MAN 3036

Series 65 Product Guide MAN 3036 Series 65 Product Guide MAN 3036 TABLE OF CONTENTS Page No. 1 Ionisation Smoke Detector... 1 1.1 Operating Principles:... 1 1.2 Product Codes... 2 1.3 Integrating Version:... 2 1.4 Options:... 2 1.5 Safety

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)

More information

DH100ACDCI Ionization Air Duct Smoke Detector

DH100ACDCI Ionization Air Duct Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS Ionization Air Duct Smoke Detector Before Installing Please thoroughly read the System Sensor Guide for Proper Use of Smoke Detectors in Duct Applications (A05-1004),

More information

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev Installation Guide for AL600ULM Multi-Output Access Control Power Supply Charger Rev. 091800 1 AL600ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL600ULM multi-output access control

More information

Conventional Smoke Detectors KFAPO

Conventional Smoke Detectors KFAPO Kingfisher Company, inc. Conventional Smoke Detectors KFAPO Features: Wide operating voltage, 9-33 VDC Advanced electronic technology Flashing LED Magnetic test switch Proven detection performance Designed

More information

Multi-Point Peripherals

Multi-Point Peripherals Multi-Point Peripherals UL, ULC, CSFM Listed; FM Approved* TrueAlarm CO Sensor Bases for Smoke, Heat, and Photo/Heat Sensors using IDNet Communications Features TrueAlarm addressable CO sensor bases contain

More information

DETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS

DETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS TEST LOG Detector Identification Information Manufacturer and Serial Date Detector Model: Number: Installed: Description of Detector Location: Test Results and Maintenance Data Date Test Test Maintenance

More information

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels R 12 Clintonville Road, Northford, CT 06472 Phone: (203) 484-7161 FAX: (203) 484-7118 Instruction Manual for the MS-4012/4024 and CMS-4012/4024 Fire Alarm Control Panels Document 15586 5/11/93 Revision:

More information

TrueAlarm ES Analog Sensing

TrueAlarm ES Analog Sensing TrueAlarm ES Analog Sensing UL, ULC, CSFM Listed; FM Approved* Features TrueAlarm addressable sensor base with 520 Hz sounder TrueAlarm sensor bases with 520 Hz tone require a TrueAlarm photoelectric,

More information

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

INSTALLATION AND MAINTENANCE

INSTALLATION AND MAINTENANCE INSTALLATION AND MAINTENANCE DH100ACDCIA & DH100ACDCPA Air Duct Smoke Detector Before Installing ULC standard CAN/ULC-S524-M91 Standard For The Installation Of Fire Alarm Systems should be referenced for

More information

Duct smoke housing, 2-wire D340/D340P

Duct smoke housing, 2-wire D340/D340P Duct smoke housing, 2-wire D340/D340P en Installation manual Duct smoke housing, 2-wire Notices en 3 1 Notices These instructions cover the installation of the D340 Duct smoke housing and D340P Duct smoke

More information

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS SXL Conventional Zone Fire Alarm Control Panel ENGINEER AND ARCHITECT SPECIFICATIONS 4 Zones Expandable to 8 Zones Microprocessor Based Control Factory Programmed Field Configurable 2 Style Y Notification

More information

DS160/DS161 Request To Exit PIR sensors Installation Instructions

DS160/DS161 Request To Exit PIR sensors Installation Instructions DS160/DS161 Request To Exit PIR sensors Installation Instructions 1.0 Description The DS160 is a Passive Infrared Detector (PIR) which is UL Listed as an Access Control Device under the UL 294 Standard.

More information

D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installing detectors, please thoroughly read the NEMA Guide for Proper Use

More information

E-PDD Duct Smoke Detector Installation Sheet

E-PDD Duct Smoke Detector Installation Sheet E-PDD Duct Smoke Installation Sheet E-PDD operation The duct smoke detector's primary purpose is to provide early warning of an impending fire and shut down the HVAC unit in order to prevent smoke from

More information

DH500ACDC Intelligent Air Duct Smoke Detector Housing

DH500ACDC Intelligent Air Duct Smoke Detector Housing INSTALLATION AND MAINTENANCE INSTRUCTIONS DH500ACDC Intelligent Air Duct Smoke Detector Housing 3825 Ohio Avenue St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6495 Specifications Length: 14.5

More information

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information: RDM LOCK G-1 1400 Series Electromagnetic Lock The patented 1400 Series Electromagnetic Lock is universal for all types of applications, including outdoor use. The innovative design will reduce installation

More information

TRN100BPT, TRN100BP, and TRN100BPC Air Duct Smoke Detector with Extended Air Speed Range

TRN100BPT, TRN100BP, and TRN100BPC Air Duct Smoke Detector with Extended Air Speed Range INSTALLATION AND MAINTENANCE INSTRUCTIONS TRN100BPT, TRN100BP, and TRN100BPC Air Duct Smoke Detector with Extended Air Speed Range 825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 60-77-6495

More information

DH100ACDCLP Air Duct Smoke Detector with Extended Air Speed Range

DH100ACDCLP Air Duct Smoke Detector with Extended Air Speed Range INSTALLATION AND MAINTENANCE INSTRUCTIONS Air Duct Smoke Detector with Extended Air Speed Range A Division of Pittway 825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 60-77-6495 The Innovair

More information

Commercial and Light Industrial Fire Alarm Control Panel

Commercial and Light Industrial Fire Alarm Control Panel FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel Features Easily expandable. All new plug-in board design Two supervised audible circuits Lamp and system trouble circuit test Ground

More information

D250A/D253/D261AW/D280A/D290 Series

D250A/D253/D261AW/D280A/D290 Series D0A/D/D6AW/D80A/D90 Series EN Installation Instructions / Smoke/Heat Detector Bases EN. D0A/D/D6AW/D80A/D90 Series Installation Instructions.0 Trademarks M Weatherban is a trademark of M. All rights reserved.

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D2 MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D2 GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

Public Safety DAS Annunciator Panel

Public Safety DAS Annunciator Panel Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This

More information

Conventional Releasing Control Panel

Conventional Releasing Control Panel s Data Sheet Fire Safety Products Conventional Releasing Control Panel Pre-Action Deluge Agent-Releasing Fire System Model TXR-320 Remote configurable Up to two (2) hazard areas Operable with the following:

More information

PSN-1000 & PSN 1000(E) Installation Manual

PSN-1000 & PSN 1000(E) Installation Manual PSN-1000 & PSN 1000(E) Installation Manual Potter Electric Signal Company, LLC St. Louis, MO Customer Service: (866) 240-1870 Technical Support: (866) 956-1211 Fax: (314) 595-6999 www.pottersignal.com

More information

WFDE Series Waterflow Detector

WFDE Series Waterflow Detector WFDE Series Waterflow Detector The System Sensor WFDE series is compatible with pipe diameters ranging from 50mm through 200mm and can be mounted in a vertical or horizontal position. Features Compliant

More information

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger Installation Guide for AL300ULM Multi-Output Access Control Power Supply Charger R AL300ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL300ULM multi-output access control power supply/charger

More information

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger Installation Guide for AL400ULM Multi-Output Access Control Power Supply Charger R AL400ULM - Multi-Output Access Control Power Supply/Charger Rev. 072500 Overview: The AL400ULM multi-output access control

More information

DS160/161 Request To Exit PIR sensors Installation Instructions

DS160/161 Request To Exit PIR sensors Installation Instructions DS160/161 Request To Exit PIR sensors Installation Instructions 1.0 Description The DS160/161 is a passive-infrared (PIR) detector designed for request to exit (REX) interior applications. It is UL Listed

More information

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL MADE IN THE U.S.A. U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION SERIAL NUMBER The Cookson Company FIREFLY II PLUS Time Delay Release

More information

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION DOCUMENT CONTROL NUMBER / MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION 1. INTRODUCTION The MR300 range of optical smoke detectors forms part of the M300 series of plug-in

More information

Installation Instructions

Installation Instructions CRSMKKIT002A00 CRSMKSEN002A00 FIELDINSTALLEDSMOKEDETECTORS FOR MEDIUM ROOFTOP UNITS 15 to 25 TONS Installation Instructions TABLE OF CONTENTS PACKAGE CONTENTS... 1 SAFETY CONSIDERATIONS... 1 GENERAL...

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

DH200RPL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

DH200RPL Intelligent Air Duct Smoke Detector with Extended Air Speed Range INSTALLATION AND MAINTENANCE INSTRUCTIONS DH200RPL Intelligent Air Duct Smoke Detector with Extended Air Speed Range 3825 Ohio Avenue, St. Charles, Illinois 60174 800/736-7672, FAX: 630-377-6495 Before

More information

RELEASE DEVICE CONTROLS

RELEASE DEVICE CONTROLS RELEASE DEVICE CONTROLS RELEASE DEVICE MODEL C+ INSTALLATION MANUAL UL LISTED CANADIAN LISTED CSFM: 7300-48:00 GENERAL DESCRIPTION: MADE IN THE U.S.A. S/N: The LM0-C+ Release Device/Control Panel is a

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 042010 Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).

More information

MODEL B2 INSTALLATION MANUAL

MODEL B2 INSTALLATION MANUAL RELEASE DEVICES GENERAL DESCRIPTION MODEL B2 INSTALLATION MANUAL S/N: The B2 Series Time Delay Release Devices are UL Listed, Canadian Listed, and CSFM Listed for use on rolling doors, single-slide and

More information

VSR-M REPLACEMENT Waterflow Switch for Globe Sprinkler Model UMC Manifold

VSR-M REPLACEMENT Waterflow Switch for Globe Sprinkler Model UMC Manifold Features NEMA 4 solid metal enclosure Factory installed neoprene gasket 0-90 second field replaceable pneumatic retard 350 PSI system pressure rated Synchronized switch action Waterflow switches that are

More information

RT-3000 SERIES NEMA 4X TYPE 4X ENCLOSURE WATERTIGHT CORROSION RESISTANT DUCT SMOKE DETECTORS

RT-3000 SERIES NEMA 4X TYPE 4X ENCLOSURE WATERTIGHT CORROSION RESISTANT DUCT SMOKE DETECTORS AIR PRODUCTS AND CONTROLS INC. 25 Corporate Drive Auburn Hills, MI 48326 USA Telephone: (248) 332-3900 www.ap-c.com AVAILABLE ACCESSORIES FOR USE WITH SERIES DUCT SMOKE DETECTORS MSR- SERIES REMOTE ACCESSORIES

More information

Addressable Fire Alarm Control Panel

Addressable Fire Alarm Control Panel PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT

More information

ANNUNCIATOR FIXED MODULE

ANNUNCIATOR FIXED MODULE 12 Clintonville Road Northford, CT 06472 Phone: 203-484-7161 Fax: 203-484-7118 THE ANNUNCIATOR FIXED MODULE Installation Manual for the AFM-16ATF and AFM-32AF Annunciator Modules Document # 15970 3/27/95

More information

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION: RELEASE DEVICES MADE IN THE U.S.A. RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: The "WPS" World Power Series, Time Delay Release

More information

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door CAUTION Hinge Edge of Door Wiring Instructions Checkmate Series with Single Point Hold-Open Combination Door Closer-Holder and Releasing Device with or without Integral Smoke Detector INSTALLER: LEAVE

More information

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA CONVENTIONAL FIRE ALARM CONTROL UNITS MR-2300 SERIES Fire Alarm Control Units Description Secutron s MR-2300 Series fire alarm control panels consist of six and twelve zone models which are equipped with

More information

DH400 Air Duct Smoke Detector

DH400 Air Duct Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS DH400 Air Duct Smoke Detector Before Installing Please thoroughly read System Sensor s Guide for Proper Use of Smoke Detectors in Duct Applications (I56-473-XX),

More information

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION AnaLASER II Detector High-Sensitivity Smoke Detector (HSSD ) F-89-250 FEATURES Air Sampling Smoke Detector for Early Warning Applications Two Versions Available: Standard Detector and Ultra Detector STANDARD

More information

good things in small packages

good things in small packages FireShield Control Panels good things in small packages life safety for small buildings and shops A perfect arrangement FireShield offers the very best conventional fire alarm technology available, with

More information

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X AL1002ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 071508X Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).

More information

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator TECHNICAL GUIDE Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator The XPlorer Range XPlorer is a new range of analogue addressable detectors and interfaces developed for all who

More information

FIRE ALARM SYSTEM FRCME AMS R2M SOM CZM DIMM. Serial. Annunciator. Printer ATG-EA ALK-V. Duct Detector SLC (DCP) Notification Alarm Equipment

FIRE ALARM SYSTEM FRCME AMS R2M SOM CZM DIMM. Serial. Annunciator. Printer ATG-EA ALK-V. Duct Detector SLC (DCP) Notification Alarm Equipment FIRE ALARM SYSTEM AMS FRCME Printer R2M SOM CZM DIMM ATG-EA Serial Annunciator ALK-V Duct Detector Notification Alarm Equipment SLC (DCP) Notification Alarm Equipment Printer (RS-232) COMMS (RS-485) EOLR

More information

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved. TX7130 Conventional Reflective Beam Detector Installation and Operation Manual Technology Copyright 2015, All right reserved. Product Safety To prevent severe injury and loss of life or property, read

More information

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL RELEASE DEVICES MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL The LiftMaster Fire Control (LM21-AFC) Release Device/Control Panel is UL/CUL listed normally energized fail-safe device incorporating

More information

Intelligent Detection Devices

Intelligent Detection Devices Intelligent Detection Devices Multi-Criteria Fire Detector [with ASAtechnology TM ] Advanced multi-criteria fire detector that has dual-optical and thermal sensors Differentiates between deceptive phenomena

More information

Installation and Operation Manual

Installation and Operation Manual [Please read this installation & operation manual before install and use this Installation and Operation Manual Address: 8-701,Dongfangming Industry Zone, Dabao Road., Baoan, Shenzhen, China-518101 Page

More information

AlarmLine Addressable Linear Heat Detector

AlarmLine Addressable Linear Heat Detector Line Addressable Linear Heat Detector P/N 7-0001-00 Effective: March 2008 K-7-02 FEATURES UL Listed FM Approved CSFM MEA (pending) Low-cost interface between Line sensor cable and control panel accepting

More information

MR-2602 Two Zone Fire Alarm Control Panel

MR-2602 Two Zone Fire Alarm Control Panel MR-2602 Two Zone Fire Alarm Control Panel Installation Manual Secutron LT-2015 Rev.3 July 2010 Table of Contents 1 Introduction 1.1 The MR-2602 Fire Alarm Control Unit... 11 1.1.1 General features...

More information

HS-100 AT-A-GLANCE MODEL NUMBER: HS-100-N 4-Wire Ionization Duct Smoke Detector HS-100-P 4-Wire Photoelectric Duct Smoke Detector

HS-100 AT-A-GLANCE MODEL NUMBER: HS-100-N 4-Wire Ionization Duct Smoke Detector HS-100-P 4-Wire Photoelectric Duct Smoke Detector AIR PRODUCTS AND CONTROLS INC. INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR SERIES PLENUM DUCT SMOKE DETECTORS NO-FLOW LOW-FLOW SPECIAL APPLICATION -N -P PRODUCT APPLICATION Series plenum / duct smoke

More information

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117 Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel Revision E 61117 CAUTION: (Read This First) This panel has been designed to make it nearly bullet proof to mistakes made when wiring

More information

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R Region Project Page 1 PART 1 - GENERAL 1.1 REFERENCES.1 CAN/ULC-S524-2006, Standard for the Installation of Fire Alarm Systems..2 CAN/ULC-S525-2007, Audible Signal Device for Fire Alarm Systems..3 CAN/ULC-S526-2007,

More information

D350PL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

D350PL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS D350PL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS I56-1975-004R Before installing detectors, please thoroughly read the NEMA Guide for

More information

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel PROTECTOWIRE FireSystems Features Easily expandable Two supervised audible circuits Lamp and system trouble circuit test Ground fault detection Initiating device circuit (IDC) alarm test Monitors up to

More information

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum. September 29, 1997 Firecycle III 433 a 1. PRODUCT NAME VIKING Model E-1 Manufactured 1997 Present 2. MANUFACTURED FOR THE VIKING CORPORATION 210 N Industrial Park Road Hastings, Michigan 49058, U.S.A.

More information

7251DH Intelligent Air Duct Smoke Detector

7251DH Intelligent Air Duct Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS 7251DH Intelligent Air Duct Smoke Detector Specifications Length: Width: Depth: Weight: Operating Temperature Range: Operating Humidity Range: Duct Air Velocity:

More information

AlarmLine Linear Heat Detector

AlarmLine Linear Heat Detector 7.01 7/11/2000 8:1 AM Page 1 CP Scan#1:Desktop Folder:hold:90 Catalog:7.01.job: 7.01 AlarmLine Linear Heat Detector FEATURES Integrating Type Linear Heat Detector Analog Sensing Field Adjustable Alarm

More information

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

THE SS90 SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL S S S S S S S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED U 99Y9 RESET L RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

Release Control Fire Alarm Systems

Release Control Fire Alarm Systems SYSTEM ABORT PUSH AND HOLD COIL SUPERVISION MODULE (2 AMP) 2081-9046 RED INSTALLATION INSTRUCTIONS 574-437 REV YEL NAC+ MAINTAIN 1/4" SEPARATION BETWEEN POWER LIMITED (RED/) AND NONPOWER S LIMITED (YEL/)

More information

Detection and Control Components

Detection and Control Components Detection and Control Components FSL-751 Very Intelligent Early Warning (VIEW ) LASER Smoke Detector with FlashScan (IQ-318/IQ-636X-2) Description The FSL-751 VIEW Laser Detector provides a revolutionary

More information

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC. M Series Multi-Output Access Control Power Supply Chargers Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 3 amp @ 12VDC or 4 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp

More information

MANUAL RESET ALARM RELEASE BOX

MANUAL RESET ALARM RELEASE BOX MANUAL RESET ALARM RELEASE BOX (For 100~240VAC or 24VAC or 24VDC) INSTRUCTION MANUAL WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts Standard Construction Control Options HEATREX offers a broad range of electrical components for temperature, safety, and power control. For most applications, the Control Option system, described in the

More information

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X AL1042ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 071508X Agency Listings: UL Listed for Control Units for Fire Protective Signaling Systems (UL

More information

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K PEGAsys Multi-Loop Intelligent Suppression Control System A UTC Fire & Security Company Effective: March 2007 K-76-028 FEATURES UL Listed CSFM Approved MEA Approved Peer-to-Peer Networking (to 32 nodes)

More information

F220-B6PS/M. Installation Guide. Addressable Detector Bases

F220-B6PS/M. Installation Guide. Addressable Detector Bases F220-B6PS/M EN Installation Guide Addressable Detector Bases F220-B6PS/M Installation Guide 1.0 Overview 1.0 Overview These instructions cover the installation of the B6PS/M Addressable Detector Bases

More information

LifeAlarm Fire Alarm Controls

LifeAlarm Fire Alarm Controls UL, ULC Approved* LifeAlarm Fire Alarm Controls 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs Features Provides additional notification appliance circuit (NAC) capacity

More information

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10 Belleville, Ontario Page 1 of 10 1 GENERAL 1.1 GENERAL REQUIREMENTS.1 The General Conditions of CCDC2-2008, and the General requirements of Division 1, form part of this Section and must read in conjunction

More information