CERTIFICATE OF COMPLIANCE
|
|
- Rodger Baker
- 6 years ago
- Views:
Transcription
1 FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA USA T: F: CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT This certificate is issued for the following equipment: FCa4cF1Y0fghijklm CoriolisMaster Integral single seal double seal with option TE2 XP-IS / I / 1 / ABCD / T6 T1* - 3KXF000028G0009; DIP / II, III / 1 / EFG / T6*; I / 1 / AEx d ia / IIC / T6 T1* - 3KXF000028G0009; 21 / AEx ia tb / IIIC / T80 C* - 3KXF000028G0009 h = material of wetted parts; A1, A2, H1, H2, C1, C2, T1 or L1 i = Flow calibration; single digit alpha numeric code not critical to safety j = Density Calibration; single digit numeric code not critical to safety k = Connection Design/Transmitter Housing Type/Transmitter Housing Material/ Cable Glands; D1, D2, D3, D4, D5, D6, D7, or D8 Additional Output 1; DRN, DRG, DRA, or DRT Page 1 of 7
2 FCa4cF1efghijY0lm CorioisMaster - Remote sensor single seal double seal with option TE2 XP-IS / I / 1 / BCD / T6 T1* - 3KXF000028G0009 DIP / II, III / 1 / EFG / T6*; I / 1 / AEx d ia / IIB+H2 / T6 T1* - 3KXF000028G0009 e = Connection Design/Connection Box Material/Cable glands; U1, U2, A1 or A2 h = Material of wetted parts; A1, A2, H1, H2, C1, C2, T1 or L1 i = Flow calibration; 2-digit alpha code not critical to safety j = Density Calibration; 2-digit numeric code not critical to safety l = Outputs; Y0 m = Power Supply; Y FCT4cF1klm CoriolisMaster Transmitter only XP-IS / I / 1 / BCD / T6 T1* - 3KXF000028G0009 DIP / II, III / 1 / EFG / T6*; I / 1 / AEx d ia / IIB+H2 / T6 T1* - 3KXF000028G0009 k = Connection Design/Transmitter Housing Type/Transmitter Housing Material/ Cable Glands; R1, R2, R3, R4, R5, R6, R7, or R8 Page 2 of 7
3 Additional Output 1; DRN, DRG, DRA, or DRT FCa4cF2Y0fghijklm CoriolisMaster Integral single seal double seal with option TE2 NI / I, II, III / 2 / ABCDEFG / T6 T1* I / 2 / AEx na / IIC / T6 T1* h = material of wetted parts; A1, A2, H1, H2, C1, C2, T1 or L1 i = Flow calibration; single digit alpha numeric code not critical to safety j = Density Calibration; single digit numeric code not critical to safety k = Connection Design/Transmitter Housing Type/Transmitter Housing Material/ Cable Glands; D1, D2, D3, D4, D5, D6, D7, or D8 Additional Output 1; DRN, DRG, DRA, or DRT 3. When m = C provision shall be made external to the equipment, to provide the transient protection device to be set at a level not exceeding 140 % of the peak rated voltage value of 42 V. Page 3 of 7
4 FCa4cF2efghijY0lm CorioisMaster - Remote sensor single seal double seal with option TE2 NI / I, II, III / 2 / ABCDEFG / T6 T1* I / 2 / AEx na / IIC / T6 T1*, IP68 e = Connection Design/Connection Box Material/Cable glands; U1, U2, A1 or A2 h = Material of wetted parts; A1, A2, H1, H2, C1, C2, T1 or L1 i = Flow calibration; 2-digit alpha code not critical to safety j = Density Calibration; 2-digit numeric code not critical to safety l = Outputs; Y0 m = Power Supply; Y FCT4cF2klm CoriolisMaster Transmitter only NI / I, II, III / 2 / ABCDEFG / T6 T1* I / 2 / AEx na / IIC / T6 T1* k = Connection Design/Transmitter Housing Type/Transmitter Housing Material/ Cable Glands; R1, R2, R3, R4, R5, R6, R7, or R8 Additional Output 1; DRN, DRG, DRA, or DRT Page 4 of 7
5 3. When m = C provision shall be made external to the equipment, to provide the transient protection device to be set at a level not exceeding 140 % of the peak rated voltage value of 42 V. Equipment Ratings: FCa4cF1Y0fghijklm CoriolisMaster Integral single seal double seal with option TE2 Explosionproof with intrinsically safe communications per control drawing - 3KXF000028G0009 for Class I, Division 1, Groups ABC&D; Dust-ignitionproof for Class II Division 1, Groups EF&G and Class III, Division 1 and 2; Flameproof with intrinsically safe communications options for Class I, Zone 1 Group IIC; Protected by enclosure with intrinsically safe communications options for Zone 21 Group IIIC hazardous (classified) locations. Temperature class T6 T1 for Class I dependent on ambient temperature and process temperature per ABB instruction Manual. Temperature class T6 for Class II and III dependent on ambient temperature and process temperature per ABB instruction Manual. Temperature class T80 C for Zone 21 dependent on ambient temperature and process temperature per ABB instruction Manual. Dual Seal or Single Seal per ANSI/ISA FCa4cF1efghijY0lm CorioisMaster - Remote sensor single seal double seal with option TE2 Explosionproof with intrinsically safe communications per control drawing - 3KXF000028G0009 for Class I, Division 1, Groups BC&D; Dust-ignitionproof for Class II Division 1, Groups EF&G and Class III, Division 1 and 2; Flameproof with intrinsically safe communications options for Class I, Zone 1 Group IIB+H2; Protected by enclosure with intrinsically safe communications options for Zone 21 Group IIIC hazardous (classified) locations. Temperature class T6 T1 for Class I dependent on ambient temperature and process temperature per ABB instruction Manual. Temperature class T6 for Class II and III dependent on ambient temperature and process temperature per ABB instruction Manual. Temperature class T80 C for Zone 21 dependent on ambient temperature and process temperature per ABB instruction Manual. Dual Seal or Single Seal per ANSI/ISA FCT4cF1klm CoriolisMaster Transmitter only Explosionproof with intrinsically safe communications per control drawing - 3KXF000028G0009 for Class I, Division 1, Groups BC&D; Dust-ignitionproof for Class II Division 1, Groups EF&G and Class III, Division 1 and 2; Flameproof with intrinsically safe communications options for Class I, Zone 1 Group IIB+H2; Protected by enclosure with intrinsically safe communications options for Zone 21 Group IIIC hazardous (classified) locations. Temperature class T6 T1 for Class I dependent on ambient temperature and process temperature per ABB instruction Manual. Temperature class T6 for Class II and III dependent on ambient temperature and process temperature per ABB instruction Manual. Temperature class T80 C for Zone 21 dependent on ambient temperature and process temperature per ABB instruction Manual. Page 5 of 7
6 FCa4cF2Y0fghijklm CoriolisMaster Integral single seal double seal with option TE2 FCa4cF2efghijY0lm CorioisMaster - Remote sensor single seal double seal with option TE2 Nonincendive for Class I, II and III, Division 2, Groups ABCDEF&G; Type of protection na for Class I, Zone 2, Group IIC Hazardous (Classified) Locations. Temperature class T6 T1 for Class I dependent on ambient temperature and process temperature per ABB instruction Manual. Dual Seal or Single Seal per ANSI/ISA FCT4cF2klm CoriolisMaster Transmitter only Nonincendive for Class I, II and III, Division 2, Groups ABCDEF&G; Type of protection na for Class I, Zone 2, Group IIC Hazardous (Classified) Locations. Temperature class T6 T1 for Class I dependent on ambient temperature and process temperature per ABB instruction Manual. FM Approved for: ABB Automation Products GmbH Göttingen, Germany Page 6 of 7
7 This certifies that the equipment described has been found to comply with the following Approval Standards and other documents: FM Class FM Class FM Class FM Class FM Class FM Class ANSI/ISA ANSI/NEMA ANSI/ISA ANSI/ISA ANSI/ISA ANSI/ISA ANSI/ISA ANSI/IEC ANSI/ISA ( ) 2009 Original Project ID: Approval Granted: October 22, 2015 Subsequent Revision Reports / Date Approval Amended Report Number Date Report Number Date RR December 29, 2015 FM Approvals LLC J.E. Marquedant Manager of Electrical Systems 29 December 2015 Date Page 7 of 7
Certificate of Compliance
Certificate of Compliance Certificate: 1182963 (066027_0_000) Issued to: WIKA Instruments Ltd. 3103 Parsons Rd Edmonton, Alberta T6N 1C8 CANADA Attention: Robert Woo The products listed below are eligible
More informationCertificate of Compliance
FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296
More informationCertificate of Compliance
FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The
More informationCertificate of Compliance
FF0002 Certificate of Compliance Certificate: 70009779 Issued to: Pepperl+Fuchs GmbH Lilienthalstrasse 200 Mannheim, 68307 GERMANY Attention: Martin Holdefer The products listed below are eligible to bear
More informationCERTIFICATE OF COMPLIANCE HAZARDOUS LOCATION ELECTRICAL EQUIPMENT PER CANADIAN REQUIREMENTS
j,!'. ;.'. FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 7624300 F: 781-762-9375 www.fmapprovals.com M('Ii/J(' (!li/w FM (i/(li1(// Groii/) CERTIFICATE OF COMPLIANCE
More informationRosemount 752 FOUNDATION Fieldbus Remote Indicator
Rosemount 752 FOUNDATION Fieldbus Remote Indicator Product Data Sheet 00813-0100-4377, Rev FA Two-wire segment powered device Displays up to eight values Link Master Capability Optional PID, Characterizer,
More informationRosemount 214C Sensor. Quick Start Guide , Rev AF August 2017
Rosemount 214C Sensor 00825-0400-2654, Rev AF NOTICE This guide provides basic guidelines for Rosemount 214C Sensor models. If the sensor was ordered assembled to a temperature thermowell or transmitter,
More informationCertificate of Compliance to IEC 61508
FM Approvals Certifies herewith that the Mechanical Products (Safety Manual [Form 1538 (3.12) 2012 SOR Inc.]) SOR Inc 14685 W 105 th St. Lenexa, KS 66215 Complies with the relevant requirements of standards
More informationRosemount 4600 Oil & Gas Panel Pressure Transmitter
Product Data Sheet October 2017 00813-0100-4022, Rev LA Rosemount 4600 Oil & Gas Panel Pressure Transmitter A compact, lightweight, all-welded stainless steel design Up to 40:1 rangeability for increased
More informationRosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017
Rosemount 0085 Pipe Clamp Sensor Assembly Quick Start Guide 00825-0100-4952, Rev DC Quick Start Guide NOTICE This guide provides basic guidelines for Rosemount 0085 Pipe Clamp Sensor. It does not provide
More informationRosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016
Rosemount 148 Temperature Transmitter 00825-0100-4148, Rev GA NOTICE This guide provides basic guidelines for the Rosemount 148. It does not provide instructions for detailed configuration, diagnostics,
More informationUL HAZARDOUS LOCATIONS SERVICES
UL HAZARDOUS LOCATIONS SERVICES The international preference in hazardous locations certification for over 100 years ul.com/hazloc Explosive Gas Atmospheres Class I Division S Includes flammable gases,
More informationQuick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly
Quick Start Guide 00825-0200-2654, Rev EA Rosemount 0065/0185 Sensor Assembly Quick Start Guide NOTICE This guide provides basic guidelines for Rosemount 0065 and 0185 Sensor models. It does not provide
More informationCertificate of Compliance
Certificate of Compliance Certificate: 70000097 Project: 70125347 Issued to: Thermo Engineering S.r.l Via Giuseppina, 19 26030 Malagnino (CR) Italy Attention: Mr. BOZZETTI The products listed below are
More informationCertificate of Compliance
Certificate of Compliance Certificate: 70033893 (166720) Issued to: WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Str 30 Klingenberg, 63911 GERMANY Attention: Uwe Schmidt The products listed below
More informationCERTIFICATE OF COMPLIANCE
CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT This certificate is issued for the following equipment: I. Nonincendive (Div. 2) Version Nil I /2/ ABCD / T* NI/I /2/ IIC
More informationccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page
Title Page ccsaus certificate: EN 70001999 for EX Meggitt SA Route de Moncor 4 PO Box 1616 CH - 1701 Fribourg Switzerland ccsaus certificate 70001999 www.meggittsensingsystems.com www.vibro-meter.com THIS
More informationTemperature Measurement Transmitters for field mounting
Siemens AG 07 Overview Application The SITRANS TF can be used everywhere where temperatures need to be measured under particularly harsh conditions. For that reasons users from all industries have opted
More informationRosemount 2090F Hygienic Pressure Transmitter
Rosemount 2090F Hygienic Pressure Transmitter Product Data Sheet December 2017 00813-0100-4698, Rev GA Conforms to 3-A Sanitary Standards Features CIP/SIP service for process temperatures up to 284 F (140
More informationRosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014
Rosemount Pipe Clamp Sensor Reference Manual Reference Manual Title Page The Rosemount 0085 Pipe Clamp Sensor NOTICE Read this manual before working with the product. For personal and system safety, and
More informationQuick Start Guide For the
A Leader in Level Measurement Quick Start Guide For the Universal IV Lite and Universal IV Pro Model Transmitters 2-Wire RF Admittance / Capacitance Level Measurement System with HART Protocol For Assistance
More informationCertificate of Compliance
Certificate of Compliance Certificate: 2557738 Master Contract: 256526 Issued to: Bartec Varnost d.o.o Cesta 9 avgusta 59 Zagorje ob Savi, 1410 Slovenia Attention: Janez Gajski The products listed below
More informationRosemount 4600 Oil & Gas Panel Pressure Transmitter. Quick Start Guide , Rev GA September 2017
Rosemount 4600 Oil & Gas Panel Pressure Transmitter 00825-0100-4022, Rev GA NOTICE NOTICE This guide provides basic guidelines for the Rosemount 4600 Oil & Gas Panel Pressure Transmitter. It does not provide
More informationCertification Supplement Manual
PROCESS ANALYSERS SERVOTOUGH Oxy Gas Analyser Certification Supplement Manual Part Number: 01910008B Revision: 9 Language: UK English This page intentionally blank SERVOTOUGH Oxy Certification Supplement
More informationGuide for hazardous areas
Guide for hazardous areas 1 Hazardous areas definitions 2 Gas and dust s 3 Temperature classifications 4 Common flammable gases, vapours and dust types 5 Protection concepts ATEX and IECEx 6 Protection
More informationAnnubar Flowmeter Series
Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA
More informationRosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016
Rosemount 0085 Pipe Clamp Sensor Assembly 00825-0100-4952, Rev CA NOTICE This guide provides basic guidelines for Rosemount 0085 Pipe Clamp Sensor. It does not provide instructions for configuration, diagnostics,
More informationAM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74
AM54 Instruction Bulletin North American Installation Addendum Document Number PN25016 Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74
More informationRosemount 2090F Hygienic Pressure Transmitter
Rosemount 2090F Hygienic Pressure Transmitter Product Data Sheet November 2016 00813-0100-4698, Rev FC Conforms to 3-A Sanitary Standards Features CIP/SIP service for process temperatures up to 284 F (140
More informationRosemount 4088B MultiVariable Transmitter with Bristol Standard Asynchronous/Synchronous Protocol (BSAP)/MVS Protocol
Quick Start Guide 00825-0200-4088, Rev CA Rosemount 4088B MultiVariable Transmitter with Bristol Standard Asynchronous/Synchronous Protocol (BSAP)/MVS Protocol Quick Start Guide NOTICE This installation
More informationYTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,
User s Manual YTA Series Temperature Transmitters [Style: S3] Manual Change No. 10-008 Please use the attached sheets in the following manuals when the product is with /KU2 option and EN60000 Series based
More informationRosemount 644 Temperature Transmitter
Quick Start Guide 00825-0200-4728, Rev GB Rosemount 644 Temperature Transmitter with 4 20 ma HART Protocol (Revision 5 and 7) Note Before installing the transmitter, confirm the correct device driver is
More informationINSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information
INSTRUCTION MANUAL D1xB2XH2 Xenon Beacon For use in Hazardous Locations 2) Rating & Marking Information 2.1 Public Mode Fire Alarm Ratings The D1xB2XH2 is certified for use as public mode visual alarm
More informationCertificate of Compliance
Certificate of Compliance Certificate: 1563164 Issued to: Metal Samples Company, A Div. of Alabama Specialty Products, Inc. 152 Metal Samples Rd PO Box 8 Munford, Alabama 36268 USA Attention: Bala Palanisamy
More informationINSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information
INSTRUCTION MANUAL D1xB2XH1 Xenon Beacon For use in Hazardous Locations 2) Rating & Marking Information 2.1 Public Mode Fire Alarm Ratings The D1xB2XH1 is certified for use as public mode visual alarm
More informationRosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013
Rosemount 248 Temperature Transmitter 00825-0100-4825, Rev. EA NOTICE This installation guide provides basic guidelines for the Rosemount 248 Wireless. It does not provide instructions for detailed configuration,
More informationAPPROVAL REPORT. J.l. 3ZOA9.AX
NOT to be distributed outside the FACTORY MUTUAL SYSTEM, except by CLIENT. APPROVAL REPORT MODEL FA-249-HA and FA-250-HA MARINE SIGNAL LANTERN USING MODEL APCL-5 FLASHCHANGER Part Numbers 8087-0122, 8087-0123,
More informationCertificate of Compliance
FF0002 Certificate of Compliance Certificate: 2792948 Issued to: Siemens Canada Limited 1954 Technology Drive Peterborough, ON K9J 7B1 Canada Attention: Mr. Lee Rogers The products listed below are eligible
More informationCertificate of Compliance
Certificate of Compliance Certificate: 2325079 Issued to: Cooper Crouse Hinds GmbH Neuer Weg Nord 49 69412 Eberbach Germany Attention: Mr Günther The products listed below are eligible to bear the CSA
More informationQuick Start Guide , Rev CB May Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol
Quick Start Guide 00825-0100-4834, Rev CB Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol Quick Start Guide NOTICE NOTICE This guide provides basic guidelines for the Rosemount
More informationQuick Start Guide , Rev DA June Rosemount 644H (Device Revision 7 or Previous) and 644R Smart Temperature Transmitters
Quick Start Guide 00825-0100-4728, Rev DA Rosemount 644H (Device Revision 7 or Previous) and 644R Smart Temperature Transmitters Quick Start Guide NOTICE This guide provides basic guidelines for the Rosemount
More informationHazardous Area Classifications and Protections
Hazardous Area Classifications Product Bulletin Hazardous Area Classifications and Protections The intent of this document is to provide a broad overview of hazardous area classifications and the types
More informationRosemount 248 Temperature Transmitter
Product Data Sheet November 2013 00813-0100-4825, Rev KA Rosemount 248 Temperature Transmitter Basic temperature transmitter offers a reliable solution for temperature monitoring points transmitter design
More informationModel 144H. Product Data Sheet , Rev DB February Content
Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy
More informationRosemount 644H Temperature Transmitters
Quick Start Guide 00825-0300-4728, Rev BA Rosemount 644H Temperature Transmitters with PROFIBUS PA Quick Start Guide NOTICE This guide provides basic guidelines for the Rosemount 644. It does not provide
More informationRosemount 3144P Temperature Transmitter
Quick Start Guide 00825-0100-4021, Rev NA Rosemount 3144P Temperature Transmitter with HART Protocol and Rosemount X-well Technology Quick Start Guide NOTICE This guide provides basic guidelines for the
More informationAdditional Information. Introduction. Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made easy
ABB MEASUREMENT & ANALYTICS COMMISSIONING INSTRUCTION TTF300 Field-mount temperature transmitter Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made
More informationRosemount 644H Temperature Transmitters
Quick Start Guide 00825-0100-4829, Rev DA Rosemount 644H Temperature Transmitters with FOUNDATION Fieldbus Quick Start Guide NOTICE This guide provides basic guidelines for the Rosemount 644. It does not
More informationRosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter
Quick Start Guide 00825-0100-4801, Rev NA Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter with HART Protocol Quick Start Guide NOTICE This guide provides basic guidelines
More informationRosemount 752 Fieldbus Remote Indicator
Product Data Sheet Rosemount 752 Rosemount 752 Fieldbus Remote Indicator ROSEMOUNT 752 DELIVERS: Two-wire segment powered device Displays up to 8 values Link Master Capability Optional PID, Characterizer,
More informationModel 144H. Product Data Sheet , Rev DB February Content
Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy
More informationRosemount 752 Remote Indicator
Quick Start Guide 00825-0100-4377, Rev EA Rosemount 752 Remote Indicator with FOUNDATION Fieldbus Protocol Quick Start Guide This guide provides basic guidelines for Rosemount 752 Remote Indicator. It
More informationPANELBOARD PROTECTION ON A GLOBAL SCALE
PANELBOARD PROTECTION ON A GLOBAL SCALE INTRODUCTION WHY? No matter what environment, location or power requirement, Appleton panelboards have you and your facility covered. From a petrochemical plant
More informationUser s Manual. EJA Series Differential Pressure and Pressure Transmitters Installation Manual. 1. Introduction. 2. Handling Cautions. 3.
User s Manual EJA Series Differential Pressure and Pressure Transmitters Installation Manual 1. Introduction 1.1 For Safe Use of Product...2 1.2 Warranty...3 1.3 ATEX Documentation...4 2. Handling Cautions
More informationRosemount 3051 Pressure Transmitter
Quick Start Guide 00825-0100-4001, rev. JA Rosemount 3051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc Low Power Protocol Rosemount 3051CF Series Flowmeter Transmitter with 4-20 ma HART and 1-5 Vdc
More informationRosemount 3051S MultiVariable Extension Supplement
Product Data Sheet April 2015 00813-0400-4801, Rev AA Rosemount 3051S MultiVariable Extension Supplement With the Rosemount 3051S MultiVariable Extensions, you can gain valuable process insight with two
More informationRosemount 2051G Pressure Transmitter
Quick Start Guide 00825-0700-4101, Rev AB Rosemount 2051G Pressure Transmitter with 4 20 ma HART Protocol (Revision 5 and 7) Quick Start Guide NOTICE This guide provides basic guidelines for Rosemount
More informationRosemount 2088 Absolute and Gage Pressure Transmitter
Product Data Sheet February 2015 00813-0100-4690, Rev PB Rosemount 2088 Absolute and Gage Pressure Transmitter Performance of 0.065% with High Accuracy option Lightweight, compact design for cost-effective
More informationCertification Supplement Manual
PROCESS ANALYSERS SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 2 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EC DECLARATION OF CONFORMITY
More informationBoth enclosures provide an IP 66 degree of ingress protection and are suitable for both indoor and outdoor installation.
Continuous Ground Loop Monitoring with visual indication. The precision and reliability of the provides enhanced safety and security by continuously testing the connection of the clamp to the container
More informationRosemount 644H Temperature Transmitters
Quick Start Guide 00825-0300-4728, Rev CA Rosemount 644H Temperature Transmitters with PROFIBUS PA Quick Start Guide NOTICE This guide provides basic guidelines for the Rosemount 644. It does not provide
More informationCertificate of Compliance
Certificate of Compliance Certificate: 1469131 (LR 103134) Master Contract: 184981 Issued to: Industrial Monitoring Instr. (IMI) A Div. of PCB Piezotronics, Inc. 3425 Walden Ave Depew, NY 14043 USA Attention:
More informationInstruction MI November I/A Series Temperature Transmitter Model RTT80-T with HART Version 6 Protocol
Instruction MI 020-582 November 2014 I/A Series Temperature Transmitter Model RTT80-T with HART Version 6 Protocol MI 020-582 November 2014 2 Contents Figures...5 Tables...7 1. Introduction...9 General
More informationQuick Start Guide , Rev DA December Rosemount Volume 1 Sensor Assembly
Quick Start Guide 00825-0300-2654, Rev DA Rosemount Volume 1 Sensor Assembly Quick Start Guide NOTICE This guide provides basic guidelines for Rosemount 0068, 0078, and 0183 Sensor models. It does not
More informationRosemount 2088, 2090F, and 2090P Pressure Transmitter
Quick Start Guide 00825-0100-4108, Rev BA Rosemount 2088, 2090F, and 2090P Pressure Transmitter with 4-20 ma HART and 1-5 Vdc Low Power HART Protocol (Revision 5 and 7) Quick Start Guide NOTICE This guide
More informationRosemount 2088, 2090P, and 2090F Pressure Transmitters
Quick Start Guide 00825-0100-4690, Rev FD Rosemount 2088, 2090P, and 2090F Pressure Transmitters with 4 20 ma HART and 1 5 Vdc HART Low Power Protocol Quick Start Guide NOTICE This installation guide provides
More informationMT5000 Guided Wave Radar Level Transmitter. State-of-the-art loop powered, 4-20 ma output guided wave radar transmitter for liquid level applications
Safety manual SM/MT5000 series-en Rev. A MT5000 Guided Wave Radar Level Transmitter State-of-the-art loop powered, 4-20 ma output guided wave radar transmitter for liquid level applications Introduction
More informationRosemount 2051 Pressure Transmitter and Rosemount 2051CF Series Flowmeter
Quick Start Guide 00825-0400-4101, Rev AD Rosemount 2051 Pressure Transmitter and Rosemount 2051CF Series Flowmeter with PROFIBUS PA Protocol Quick Start Guide NOTICE This installation guide provides basic
More informationS5000 Gas Monitor. GMS5000.com
S5000 Gas Monitor GMS5000.com A DETECTOR AS TOUGH AS YOU ARE... LOWER TEMPERATURE SPEC?... ARCTIC WINTERS IT HAS TO BE THE MOST RELIABLE PIECE OF EQUIPMENT OUT HERE IF THE DETECTOR DOESN T WORK, WE DON
More informationIECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Certificate history: Status:
More informationRosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series MultiVariable Flowmeter
Quick Start Guide 00825-0100-4853, Rev AD Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series MultiVariable Flowmeter with FOUNDATION Fieldbus Protocol Quick Start Guide NOTICE This guide
More informationAn Urgent Bulletin from CSA Group
An Urgent Bulletin from CSA Group Hazardous Locations Products No. 28 (Supersedes Electrical Certification Notice No. 544A) Date: January 3, 2018 See Attachment 1 for Effective Dates. See Attachment 1
More informationCertificate of Compliance
Certificate of Compliance Certificate: 70067850 Date Issued: July 28, 2017 Issued to: Otis Instruments, Incorporated 301 S. Texas Ave. Bryan, Texas, 77803 USA Attention: Nicholas Sandera The products listed
More informationSTT 3000 Series STT250 SMART TEMPERATURE TRANSMITTER Models STT25H, STT25M, STT25D
STT 3000 Series STT250 SMART TEMPERATURE TRANSMITTER Models STT25H, STT25M, STT25D EN0I-6031 12/00 PRODUCT SPECIFICATION SHEET OVERVIEW Honeywell s STT 3000 family of microprocessor based smart temperature
More informationRosemount 848T High Density Temperature Measurement Family
Product Data Sheet July 2017 00813-0100-4697, Rev PA Rosemount 848T High Density Temperature Measurement Family Innovative temperature measurement for high density applications that provide installation
More informationRosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series Flowmeter MultiVariable Transmitter
Quick Start Guide 00825-0100-4803, Rev EF Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series Flowmeter MultiVariable Transmitter Quick Start Guide NOTICE This guide provides basic guidelines
More informationOfficine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0
Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:
More informationfor CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN
Title page CCSAUS certificate: EN 70034691 for EX Meggitt SA Route de Moncor 4 PO Box 1616 CH - 1701 Fribourg Switzerland CCSAUS certificate 70034691 www.meggittsensingsystems.com www.vibro-meter.com THIS
More informationBrooks MT3750 Low Flow Armored Flowmeter
Brooks MT3750 Low Flow Armored Flowmeter ArMite TM Model MT3750 Metal Tube Flowmeter ArMite TM Model MT3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm Benefits: Wetted Parts made from Stainless
More informationRosemount 3144P Temperature Transmitter
Product Data Sheet August 2014 00813-0100-4021, Rev NA Rosemount 3144P Temperature Transmitter For every responsibility you have, you are confronted with a number of challenges. You have aggressive production
More informationUL Topic III. Converting European EEx Certificates. Into. North American Division Certificates
Note: While this material was originally prepared for presentation in February 1999, it has been updated to reflect the evolving technical requirements now applicable as of April 2003. UL Topic III Converting
More informationIntegrated Solutions Low Voltage Systems
Integrated Solutions Low Voltage Systems 612 Contents Energy Distribution Overview Module Technology 8146 614 Overview Flameproof Enclosures 8220 614 Overview Flameproof Enclosures 8261 614 Overview CUBEx
More informationAr-Mite TM Low Flow Armored Flowmeter
Data Sheet Brooks Ar-Mite TM MT 3750C Ar-Mite TM Low Flow Armored Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm
More informationINSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations
INSTRUCTION MANUAL E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING
More informationCertificate of Compliance
Certificate of Compliance Certificate: 1238566 Issued to: Rosemount Analytical Inc. Solon Research & Development Ctr 6565-P Davis Industrial Pkwy Solon, OH 44139 USA Attention: Dana Crowley The products
More informationRosemount 2088, 2090F, and 2090P Pressure Transmitter
Quick Start Guide 00825-0100-4108, Rev CA Rosemount 2088, 2090F, and 2090P Pressure Transmitter with 4 20 ma HART and 1 5 Vdc Low Power HART Protocol (Revision 5 and 7) Quick Start Guide NOTICE This guide
More informationINSTRUCTION & SERVICE MANUAL
INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following
More informationCOMPACT FLAME CONTROLLER CFC 2000
COMPACT FLAME CONTROLLER CFC 2000 TECHNICAL DESCRIPTION EDITION: TB_CFC2000_EN_REV09_20150408 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring
More informationSafety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******
Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O****** CSA 14.2662675 Ex ia IIC T6 Ga, Gb 0044 Document ID: 48924 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical
More informationRosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter
Quick Start Guide 00825-0100-4801, Rev MC Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter with HART Protocol Quick Start Guide NOTICE This guide provides basic guidelines
More informationRosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series Flowmeter MultiVariable Transmitter
Quick Start Guide 00825-0100-4803, Rev EA Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series Flowmeter MultiVariable Transmitter Quick Start Guide NOTICE This guide provides basic guidelines
More informationRosemount 3144P Temperature Transmitter
00825-0100-4021, Rev MA Rosemount 3144P Temperature Transmitter with HART Protocol and Rosemount X-well Technology NOTICE This guide provides basic guidelines for the Rosemount 3144P Transmitter. It does
More informationSpecifying Temperature Sensors for Hazardous Areas
Specifying Temperature Sensors for Hazardous Areas The manufacture of petroleum products, paint, and many chemicals can lead to the release of flammable gases. When these gases accumulate in enclosed areas,
More informationFLASHLIGHT ANSI STANDARDS
FLASHLIGHT ANSI STANDARDS While Pelican was one of the first manufacturers to use quantifiable test procedures, the need was recognized to develop a common language that customers could use to select the
More informationNational Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:
National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: NEC Code-Making Panel 14 FROM: Kimberly Shea DATE:
More informationULTIMA X5000. MSAX5000.com
ULTIMA X5000 MSAX5000.com WE KNOW YOU RE TIRED OF... NEEDING TO DISCONNECT POWER BEFORE CHANGING A SENSOR REMEMBERING HOW TO CALIBRATE THIS THING HAVING TO PULL SO MUCH WIRE AT EVERY GAS DETECTOR INSTALLATION...
More informationExplosion Proof Combination Signal db (A) / 5 Joule
Explosion Proof Combination Signal - Operating instructions Additional languages www.r-stahl.com General information Contents 1 General information...2 1.1 Manufacturer...2 1.2 Information regarding the
More informationRosemount 3051 Pressure Transmitter and Rosemount 3051CF Series Flowmeter
Quick Start Guide 00825-0100-4797, Rev ED Rosemount 3051 Pressure Transmitter and Rosemount 3051CF Series Flowmeter with PROFIBUS PA Protocol Quick Start Guide NOTICE This installation guide provides basic
More informationofficial distributor of Newson Gale Ltd.
Continuous Ground Loop Monitoring with visual indication. The precision and reliability of the provides enhanced safety and security by continuously testing the connection of the clamp to the container
More informationQuick Start Guide , Rev HA January Rosemount 248 Temperature Transmitter
00825-0100-4825, Rev HA Rosemount 248 Temperature Transmitter NOTICE This guide provides basic guidelines for the Rosemount 248. It does not provide instructions for detailed configuration, diagnostics,
More information