1 Integral Consulting Inc. 285 Century Place Suite 190 Louisville, CO telephone: facsimile: June 19, 2017 Project No. C594 Andrew Nichols Remediation Division Minnesota Pollution Control Agency 520 Lafayette Road St. Paul, MN Subject: Soil Vapor Extraction Shutdown Evaluation Report Former Ashland Lease Area Soo Line Shoreham Yard (SF) Site ID SR380 Dear Andrew: On behalf of Ashland Inc. (Ashland), this letter provides the results for shutdown testing of the Former Ashland Lease Area (FALA) soil vapor extraction (SVE) system and a work plan for soil gas sampling on the east side of Central Avenue. SHUTDOWN EVALUATION Per the 2005 interim response action plan (IRAP) 1, SVE shutdown testing in the form of rebound and restart evaluations can commence at the point that an asymptotically low rate of mass removal is observed. The IRAP states that if the mass removal rate repeatedly rebounds not more than 15 percent higher than the asymptotic removal rate, the system will be shut down. The FALA alluvium SVE system reached a state of asymptotic removal in The till SVE system was near asymptotic in 2012, with low mass removal rates, and continued to operate to stimulate aerobic degradation at the water table until late 2016, when the till system also reached an asymptotic state. The FALA SVE shutdown test occurred from December 2016 to January 2017 and consisted of three cycles, each with one 1 Golder Interim response action plan for the former Ashland/Rocket lease area, East Side Shoreham facility, VIC program site ID VP5080 and the Petroleum Brownfields Program leak site No , Minneapolis, MN. May. Golder Associates Inc., Cherry Hill, NJ.
2 Andrew Nichols June 19, 2017 Page 2 week of system shutdown followed by one week of system operation. The test was performed in accordance with the October 3, work plan, approved by the Minnesota Pollution Control Agency (MPCA) on November 2, Prior to the start of the test, an ad hoc soil gas sample was collected for volatile organic compound (VOC) analysis by U.S. Environmental Protection Agency TO-15 from the shallow vapor monitoring point T-VM-4S. T-VM-4S serves as a receptor-depth (4 feet below ground surface) location on the east side of Central Avenue (Figure 1). Sampling of T-VM-4S began in 2013, upon temporary shutdown of the alluvium SVE system, and sampling was suspended in 2014, after trichloroethene (TCE) concentrations in two successive warm weather samples were below the MPCA intrusion screening value (ISV) for commercial/industrial sub-slab air. T-VM-4S was not scheduled to be monitored again until after final rebound testing; however, it was decided sampling before rebound testing (till system in operation) would be beneficial to evaluate conditions after the 2-year alluvium system shutdown period. Additional ad hoc VOC samples from T-VM-4S were planned during the rebound test while both SVE systems were off. However, no further samples could be collected as the shallow vapor monitoring point was blocked by ice near the ground surface for the duration of the test. Following collection of the soil gas sample on December 6, 2016, the alluvium system was restarted. Initial samples for VOC analysis were collected from the till and alluvium manifolds on December 13 and 14, 2016, respectively, after the alluvium system had been on for 1 week. The sample canister for the initial alluvium manifold sample was received without vacuum, delaying the sample collection and start of the test by 1 day until a replacement canister was obtained. No further sample collection issues were encountered during the test. The first shutdown test cycle began on December 14, 2016, with the shutdown of both the till and alluvium systems. On December 20, 2016, after the 1-week rebound period, both systems were turned on and VOC samples were collected from the till and alluvium manifolds at 2 hours, 24 hours, 72 hours, and 1 week after system restart. The manifolds were also monitored by photoionization detector (PID) at the same time intervals after system restart. System operational data were collected during each site visit. The second and third shutdown test cycles proceeded in the same manner, and the test was concluded on January 24, The alluvium system was shut off at the conclusion of the test and the till system remained on. 2 Integral Soil vapor extraction system operations, Former Ashland Lease Area Soo Line Shoreham Yard (SF), Site ID SR380. October 3. Integral Consulting Inc., Louisville, CO.
3 Andrew Nichols June 19, 2017 Page 3 SHUTDOWN EVALUATION RESULTS VOC results for the till and alluvium manifolds are presented in Tables 1 and 2, respectively. The sum of chlorinated, non-chlorinated, and all VOCs is presented at the bottom of each table. VOCs detected in both systems consisted mainly of chlorinated VOCs and ranged from 158 to 1,252 µg/m 3 total VOCs in the till and 64 to 1,285 µg/m 3 total VOCs in the alluvium. PID readings were low throughout the test, ranging from 0 to 0.2 ppm, and therefore were not used in the rebound evaluation. All VOC laboratory reports are attached in Appendix A. Table 3 contains a summary of VOC concentrations, flow rates, mass removed, and mass removal rates for each system. First, instantaneous removal rates were calculated at each sample time by multiplying the concentration by the flow rate. Then, the mass removed for each time interval was calculated using the instantaneous removal rates (e.g., the 2-hour sample was used to calculate the mass removed from 0 to 2 hours after system restart, the average of the 2-hour and 24-hour samples was used to calculate the mass removed from 2 to 24 hours). An average cycle recovery rate was calculated by dividing the total mass removed by the total elapsed time, including the shutdown period (i.e., the entire 2-week cycle). The rates for the three cycles were then averaged to determine the overall shutdown test removal rates. At the bottom of Table 3, the overall average shutdown test removal rate (average of the three cycles) is compared to the average asymptotic removal rate for each system. The shutdown test rates were an order of magnitude lower than the asymptotic rates for both systems, lb/hr versus lb/hr in the till system and lb/hr versus lb/hr in the alluvium system. The asymptotic removal rates are defined as the average rate for the period used in the Mann-Kendall trend analysis (presented in August 14, and October 3, letters to MPCA). The average rates as well as the instantaneous rates are displayed in Figure 2. In addition to the low shutdown test removal rates, no single instantaneous removal rate rebounded above the average asymptotic rates in the respective systems. Table 4 presents TCE results from shallow vapor monitoring point, T-VM-4S, on the east side of Central Avenue. The December 6, 2016, sample, collected prior to the test, contained 96 µg/m 3 TCE. Although this concentration is increased compared to the samples collected in 2013 and 2014, it is below the MPCA commercial/industrial sub-slab 3 Integral Vapor investigation and soil vapor extraction system operations, Former Ashland Lease Area Soo Line Shoreham Yard (SF), Site ID SR380. August 14. Integral Consulting Inc., Louisville, CO. 4 See footnote 2.
4 Andrew Nichols June 19, 2017 Page 4 air ISV of 230 µg/m 3 (i.e., 33 times the commercial/industrial indoor air ISV). 5 All other detected compounds were also below their respective commercial/industrial sub-slab air ISVs. SYSTEM SHUTDOWN AND SOIL GAS REBOUND TESTING Because recent shutdown testing performed at the FALA did not rebound above the asymptotic removal rate, it is recommended that the FALA till and alluvium systems be shut down while confirmatory soil and soil gas testing are performed. The IRAP states soil gas testing shall be performed in the median of Central Avenue and at the eastern side of Central Avenue. Because of access issues on the median of Central Avenue and the low recovery rates observed during rebound testing, Ashland proposes to monitor only the T-VM-4S point on the east side of Central Avenue, commencing in the third quarter of Soil gas rebound testing would proceed in the same manner as outlined in the August 14, 2012, letter when the alluvium system was first shut down. Samples will be collected quarterly for one year and analyzed for VOCs by TO-15. If two successive warm weather samples (when concentrations peak) are less than the commercial/industrial subslab air ISVs, soil gas monitoring will be concluded. However, if T-VM-4S VOC concentrations are above the commercial/industrial sub-slab air ISVs, then a plan for delineation of the extent of soil gas above ISVs will be submitted to MPCA. A separate work plan will be submitted for confirmatory soil testing. We would appreciate a response to this letter by June 30, 2017, so that we may initiate soil gas testing for the remaining warm weather season in If you have any questions, please call me at (720) Sincerely, Steven O. Helgen Principal Geochemist Enclosures 5 MPCA Interim ISV short guidance. February 13. Minnesota Pollution Control Agency, Minneapolis, MN.
5 Andrew Nichols June 19, 2017 Page 5 cc: Tom Frame, City of Minneapolis James Vondracek, Ashland LeeAnn Thomas, CP Aimee Zack, CP Steve Finn, Golder Claire Mackler, Golder Councilman Kevin Reich, Minneapolis City Council First Ward Michelle Brodin, Stinson Leonard Street
6 FIGURES
7 } } } } } } } } } } } } } } } } } } } } } } } N:\GIS\Projects\C594_AshlandAve_AI\Production_MXDs\2013_Site_Report\Figure_2-1_SVE_&_monitoring_points_ mxd } } } } } } } } } } } } } } } } } } } } } } } } } } } } } } } } } } } } } } } } VEW A50N VEW T-1 VEW A VEW05-79-T-7 } } } } #* #* #* #* } } } } } A-VM-1 T-VM-1 VEW05-73-A-4 #* VEW05-76-T-4 VEW05-75-T-3 T-VM-2 A-VM-2 #* #* #* #* } } } } } } } } VEW05-80-T-8 VEW05-74-A-5 VEW05-81-T-9 T-VM-7 A-VM-5 VEW05-77-T-5 T-VM-3 #* VEW A40-E VEW T-30N T-VM-5 A-VM-4 T-VM-6 VEW05-78-T-6 A-VM-3 #* T-VM-4S T-VM Feet Map Features #* #* Till, Vapor Monitoring Well FALA Boundary Alluvium, Vapor Monitoring Well } } Fence Till, SVE Well Gate Alluvium, SVE Well SVE Pipe Figure 1. Location of SVE Vapor Extraction Wells and Monitoring Points at the Former Ashland Lease Area
8 0.005 FALA SVE Shutdown Test VOC Mass Removal Rates Alluvium Average Asymptotic Mass Removal Rate (April 2010 to April 2012) /14/ /15/ /16/ /17/ /18/ /19/ /20/ /21/ /22/ /23/ /24/ /25/ /26/ /27/ /28/ /29/ /30/ /31/2016 1/1/2017 1/2/2017 1/3/2017 1/4/2017 1/5/2017 1/6/2017 1/7/2017 1/8/2017 1/9/2017 1/10/2017 1/11/2017 1/12/2017 1/13/2017 1/14/2017 1/15/2017 1/16/2017 1/17/2017 1/18/2017 1/19/2017 1/20/2017 VOC Mass Removal Rate (lb/hr) 1/21/2017 1/22/2017 1/23/2017 1/24/2017 Till Average Asymptotic Mass Removal Rate (June 2014 to March 2016) Rebound System OFF Restart System ON CYCLE 1 Rebound System OFF Restart System ON CYCLE 2 Rebound System OFF Restart System ON CYCLE 3 Till Shutdown Test Till Shutdown Test Avg Till Asymptotic Avg Alluvium Shutdown Test Alluvium Shutdown Test Avg Alluvium Asymptotic Avg Figure 2. SVE Shutdown Test VOC Mass Removal Rates and Average Shutdown Test and Average Asymptotic Removal Rates in the Till and Alluvium SVE Systems
9 TABLES
10 SVE Shutdown Evaluation Report Former Ashland Lease Area June 19, 2017 Table 1. VOCs Measured ( TO-15) in the Till Manifold Till Manifold Concentration (µg/m 3 ) Cycle 1 Cycle 2 Cycle 3 Initial Off On 2 hr On 24 hr On 72 hr On 1 wk Off On 2 hr On 24 hr On 72 hr On 1 wk Off On 2 hr On 24 hr On 72 hr On 1 wk Analyte 12/13/ /20/ /21/ /23/ /27/2016 1/3/2017 1/4/2017 1/6/2017 1/10/2017 1/17/2017 1/18/2017 1/20/2017 1/24/2017 Freon ND ND ND ND ND ND ND ND ND ND ND ND Freon 114 ND ND ND ND ND ND ND ND ND ND ND ND ND Chloromethane ND ND ND ND ND ND ND ND ND ND ND ND ND Vinyl Chloride ND ND ND ND ND ND ND ND ND ND ND ND ND 1,3-Butadiene ND ND ND ND ND ND ND ND ND ND ND ND ND Bromomethane ND ND ND ND ND ND ND ND ND ND ND ND ND Chloroethane ND ND ND ND ND ND ND ND ND ND ND ND ND Freon 11 ND ND ND ND ND ND ND ND ND ND ND ND ND Ethanol ND ND ND 7.9 ND ND ND 7.1 ND ND Freon 113 ND ND ND ND ND ND ND ND ND ND ND ND ND 1,1-Dichloroethene ND ND ND ND ND ND ND ND ND ND ND ND ND Acetone 22 ND ND 40 ND ND ND 23 ND ND ND 2-Propanol ND ND ND ND ND ND ND ND ND ND ND Carbon Disulfide ND ND ND ND ND ND ND ND ND ND ND ND ND 3-Chloropropene ND ND ND ND ND ND ND ND ND ND ND ND ND Methylene Chloride ND ND ND ND ND ND ND ND ND ND ND ND ND Methyl tert-butyl Ether ND ND ND ND ND ND ND ND ND ND ND ND ND trans-1,2-dichloroethene 3.7 ND ND ND ND ND ND ND ND ND ND ND ND Hexane 4.2 ND ND ND ND ND ND ND ND ND ND ND ND 1,1-Dichloroethane 11 5 ND ND ND 3.7 ND ND ND 3.4 ND ND ND 2-Butanone (Methyl Ethyl Ketone) 9.5 ND ND 13 ND ND ND ND ND ND ND cis-1,2-dichloroethene Tetrahydrofuran ND ND ND ND ND ND ND ND ND ND ND ND ND Chloroform ND ND ND ND ND ND ND ND ND ND ND ND ND 1,1,1-Trichloroethane Cyclohexane ND ND ND ND ND ND ND ND ND ND ND ND ND Carbon Tetrachloride ND ND ND ND ND ND ND ND ND ND ND ND ND 2,2,4-Trimethylpentane ND ND ND ND ND ND ND ND ND ND ND ND ND Benzene ND ND ND ND ND ND ND ND ND ND 3.3 ND ND 1,2-Dichloroethane ND ND ND ND ND ND ND ND ND ND ND ND ND Heptane ND ND ND ND ND ND ND ND ND ND ND ND ND Trichloroethene ,2-Dichloropropane ND ND ND ND ND ND ND ND ND ND ND ND ND 1,4-Dioxane ND ND ND ND ND ND ND ND ND ND ND ND ND Bromodichloromethane ND ND ND ND ND ND ND ND ND ND ND ND ND cis-1,3-dichloropropene ND ND ND ND ND ND ND ND ND ND ND ND ND 4-Methyl-2-Pentanone ND ND ND ND ND ND ND ND ND ND ND ND ND Toluene 9 ND ND ND ND ND ND 4.4 ND ND 5.9 ND ND Integral Consulting Inc. Page 1 of 2
11 SVE Shutdown Evaluation Report Former Ashland Lease Area June 19, 2017 Table 1. VOCs Measured ( TO-15) in the Till Manifold Cycle 1 Till Manifold Concentration (µg/m 3 ) Cycle 2 Cycle 3 Initial On 2 hr On 24 hr On 72 hr On 1 wk On 2 hr On 24 hr On 72 hr On 1 wk On 2 hr On 24 hr On 72 hr On 1 wk Off Off Off Analyte 12/13/ /20/ /21/ /23/ /27/2016 1/3/2017 1/4/2017 1/6/2017 1/10/2017 1/17/2017 1/18/2017 1/20/2017 1/24/2017 trans-1,3-dichloropropene ND ND ND ND ND ND ND ND ND ND ND ND ND 1,1,2-Trichloroethane Tetrachloroethene Hexanone ND ND ND ND ND ND ND ND ND ND ND ND ND Dibromochloromethane ND ND ND ND ND ND ND ND ND ND ND ND ND 1,2-Dibromoethane (EDB) ND ND ND ND ND ND ND ND ND ND ND ND ND Chlorobenzene ND ND ND ND ND ND ND ND ND ND ND ND ND Ethyl Benzene ND ND ND ND ND ND ND ND ND ND ND ND ND m,p-xylene ND ND ND ND ND ND ND ND ND ND ND o-xylene ND ND ND ND ND ND ND ND ND ND ND ND ND Styrene ND ND ND ND ND ND ND ND ND ND ND ND ND Bromoform ND ND ND ND ND ND ND ND ND ND ND ND ND Cumene ND ND ND ND ND ND ND ND ND ND ND ND ND 1,1,2,2-Tetrachloroethane ND ND ND ND ND ND ND ND ND ND ND ND ND Propylbenzene ND ND ND ND ND ND ND ND ND ND ND ND ND 4-Ethyltoluene ND ND ND ND ND ND ND ND ND ND ND ND ND 1,3,5-Trimethylbenzene ND ND ND ND ND ND ND ND ND ND ND ND ND 1,2,4-Trimethylbenzene ND ND ND ND ND ND ND ND ND ND ND ND ND 1,3-Dichlorobenzene ND ND ND ND ND ND ND ND ND ND ND ND ND 1,4-Dichlorobenzene ND ND ND ND ND ND ND ND ND ND ND ND ND alpha-chlorotoluene ND ND ND ND ND ND ND ND ND ND ND ND ND 1,2-Dichlorobenzene ND ND ND ND ND ND ND ND ND ND ND ND ND 1,2,4-Trichlorobenzene ND ND ND ND ND ND ND ND ND ND ND ND ND Hexachlorobutadiene ND ND ND ND ND ND ND ND ND ND ND ND ND Chlorinated Organics (µg/m 3 ) 1, Non-chlorinated Organics (µg/m 3 ) Total Organics (µg/m 3 ) 1, Notes: ND = analyte not detected VOC = volatile organic compound Integral Consulting Inc. Page 2 of 2
12 SVE Shutdown Evaluation Report Former Ashland Lease Area June 19, 2017 Table 2. VOCs Measured ( TO-15) in the Alluvium Manifold Alluvium Manifold Concentration (µg/m 3 ) Cycle 1 Cycle 2 Cycle 3 Initial Off On 2 hr On 24 hr On 72 hr On 1 wk Off On 2 hr On 24 hr On 72 hr On 1 wk Off On 2 hr On 24 hr On 72 hr On 1 wk Analyte 12/14/ /20/ /21/ /23/ /27/2016 1/3/2017 1/4/2017 1/6/2017 1/10/2017 1/17/2017 1/18/2017 1/20/2017 1/24/2017 Freon ND ND 4.6 ND ND ND 5.2 Freon 114 ND ND ND ND ND ND ND ND ND ND ND ND ND Chloromethane ND ND ND ND ND ND ND ND ND ND ND ND ND Vinyl Chloride ND ND ND ND ND ND ND ND ND ND ND ND ND 1,3-Butadiene ND ND ND ND ND ND ND ND ND ND ND ND ND Bromomethane ND ND ND ND ND ND ND ND ND ND ND ND ND Chloroethane ND ND ND ND ND ND ND ND ND ND ND ND ND Freon 11 ND ND ND ND ND ND ND ND ND ND ND ND ND Ethanol ND ND 6.1 ND ND ND ND ND ND ND ND 19 ND Freon 113 ND ND ND ND ND ND ND ND ND ND ND ND ND 1,1-Dichloroethene ND ND ND ND ND ND ND ND ND ND ND ND ND Acetone ND ND ND ND ND ND ND ND ND ND ND 20 ND 2-Propanol ND ND 8.7 ND ND ND ND ND 10 ND ND 8.9 ND Carbon Disulfide ND ND ND ND ND ND ND ND ND ND ND ND ND 3-Chloropropene ND ND ND ND ND ND ND ND ND ND ND ND ND Methylene Chloride ND ND ND ND ND ND ND ND ND ND ND ND ND Methyl tert-butyl Ether ND ND ND ND ND ND ND ND ND ND ND ND ND trans-1,2-dichloroethene ND ND ND ND ND ND ND ND ND ND ND ND ND Hexane ND ND ND ND ND ND ND ND ND ND ND ND 3.1 1,1-Dichloroethane ND ND ND ND ND ND ND ND ND 2-Butanone (Methyl Ethyl Ketone) ND ND ND ND ND ND ND 15 ND ND ND 10 ND cis-1,2-dichloroethene ND ND ND ND 5.1 ND 6.1 Tetrahydrofuran ND ND ND ND ND ND ND ND ND ND ND 2.3 ND Chloroform ND ND ND ND ND ND ND ND ND ND ND ND ND 1,1,1-Trichloroethane ND Cyclohexane ND ND 6.6 ND ND ND ND ND ND ND ND ND ND Carbon Tetrachloride ND ND ND ND ND ND ND ND ND ND ND ND ND 2,2,4-Trimethylpentane ND ND ND ND ND ND ND ND ND ND ND ND ND Benzene ND ND ND ND ND ND ND ND ND ND ND 3.8 ND 1,2-Dichloroethane ND ND ND ND ND ND ND ND ND ND ND ND ND Heptane ND ND ND ND ND ND ND ND ND ND ND ND ND Trichloroethene ,2-Dichloropropane ND ND ND ND ND ND ND ND ND ND ND ND ND 1,4-Dioxane ND ND ND ND ND ND ND ND ND ND ND ND ND Bromodichloromethane ND ND ND ND ND ND ND ND ND ND ND ND ND cis-1,3-dichloropropene ND ND ND ND ND ND ND ND ND ND ND ND ND 4-Methyl-2-Pentanone ND ND ND ND ND ND ND ND ND ND ND ND ND Toluene ND ND ND ND ND ND ND ND ND ND ND ND ND Integral Consulting Inc. Page 1 of 2
13 SVE Shutdown Evaluation Report Former Ashland Lease Area June 19, 2017 Table 2. VOCs Measured ( TO-15) in the Alluvium Manifold Cycle 1 Alluvium Manifold Concentration (µg/m 3 ) Cycle 2 Cycle 3 Initial On 2 hr On 24 hr On 72 hr On 1 wk On 2 hr On 24 hr On 72 hr On 1 wk On 2 hr On 24 hr On 72 hr On 1 wk Off Off Off Analyte 12/14/ /20/ /21/ /23/ /27/2016 1/3/2017 1/4/2017 1/6/2017 1/10/2017 1/17/2017 1/18/2017 1/20/2017 1/24/2017 trans-1,3-dichloropropene ND ND ND ND ND ND ND ND ND ND ND ND ND 1,1,2-Trichloroethane ND ND 5.5 ND 6.7 ND 4.5 Tetrachloroethene Hexanone ND ND ND ND ND ND ND ND ND ND ND ND ND Dibromochloromethane ND ND ND ND ND ND ND ND ND ND ND ND ND 1,2-Dibromoethane (EDB) ND ND ND ND ND ND ND ND ND ND ND ND ND Chlorobenzene ND ND ND ND ND ND ND ND ND ND ND ND ND Ethyl Benzene ND ND ND ND ND ND ND ND ND ND ND ND ND m,p-xylene ND ND ND ND ND ND ND ND ND ND ND ND ND o-xylene ND ND ND ND ND ND ND ND ND ND ND ND ND Styrene ND ND ND ND ND ND ND ND ND ND ND ND ND Bromoform ND ND ND ND ND ND ND ND ND ND ND ND ND Cumene ND ND ND ND ND ND ND ND ND ND ND ND ND 1,1,2,2-Tetrachloroethane ND ND ND ND ND ND ND ND ND ND ND ND ND Propylbenzene ND ND ND ND ND ND ND ND ND ND ND ND ND 4-Ethyltoluene ND ND ND ND ND ND ND ND ND ND ND ND ND 1,3,5-Trimethylbenzene ND ND ND ND ND ND ND ND ND ND ND ND ND 1,2,4-Trimethylbenzene ND ND ND ND ND ND ND ND ND ND ND ND ND 1,3-Dichlorobenzene ND ND ND ND ND ND ND ND ND ND ND ND ND 1,4-Dichlorobenzene ND ND ND ND ND ND ND ND ND ND ND ND ND alpha-chlorotoluene ND ND ND ND ND ND ND ND ND ND ND ND ND 1,2-Dichlorobenzene ND ND ND ND ND ND ND ND ND ND ND ND ND 1,2,4-Trichlorobenzene ND ND ND ND ND ND ND ND ND ND ND ND ND Hexachlorobutadiene ND ND ND ND ND ND ND ND ND ND ND ND ND Chlorinated Organics (µg/m 3 ) 290 1,285 1, Non-chlorinated Organics (µg/m 3 ) Total Organics (µg/m 3 ) 290 1,285 1, Notes: ND = analyte not detected VOC = volatile organic compound Integral Consulting Inc. Page 2 of 2
14 SVE Shutdown Evaluation Report Former Ashland Lease Area June 19, 2017 Table 3. Summary of SVE Shutdown Evaluation Results Cycle and Sample Time Total VOCs (µg/m 3 ) Flow Rate (SCFM) Instantaneous Removal Rate (lb/hr) Mass Removed (lb) Time Interval (hr) Average Cycle Removal Rate (lb/hr) Till Alluvium Till Alluvium Till Alluvium Till Alluvium Till Alluvium Sample Date 12/13/2016, 12/14/2016 a Initial 1, Cycle 1 - Off 1 wk /20/2016 Cycle 1 - On 2 hr 772 1, b b 12/21/2016 Cycle 1 - On 24 hr 400 1, b b 12/23/2016 Cycle 1 - On 72 hr /27/2016 Cycle 1 - On 1 wk Cycle 1 - Sum Cycle 2 - Off 1 wk /3/2017 Cycle 2 - On 2 hr /4/2017 Cycle 2 - On 24 hr b b /6/2017 Cycle 2 - On 72 hr b b /10/2017 Cycle 2 - On 1 wk Cycle 2 - Sum Cycle 3 - Off 1 wk /17/2017 Cycle 3 - On 2 hr /18/2017 Cycle 3 - On 24 hr b b /20/2017 Cycle 3 - On 72 hr b b /24/2017 Cycle 3 - On 1 wk Cycle 3 - Sum Shutdown Test Average Removal Rate Asymptotic Average Removal Rate Notes: SCFM = standard cubic feet per minute SVE = soil vapor extraction VOC = volatile organic compound -- = not available Nondetected values were not included in the total VOCs sum. a Due to receipt of a sample canister without vacuum, the till sample was collected on 12/13/2016 and the alluvium sample was collected on 12/14/2016. The first rebound cycle was begun on 12/14/2016 and is therefore 6 days in length. b Flow rates were not recorded for 24-hr and 72-hr samples. An average of the 2-hr and 1-wk cycle samples was used to calculate mass removal rates. Integral Consulting Inc. Page 1 of 1
15 SVE Shutdown Evaluation Report Former Ashland Lease Area June 19, 2017 Table 4. Concentrations of Trichloroethene (TCE) in Shallow Monitoring Point T-VM-4S Sampling Location Sampling Date TCE Concentration (µg/m 3 ) System Operating Status Alluvium SVE Till SVE 7/16/2013 ND On On 9/24/ Off On T-VM-4S 12/18/2013 ND Off On 3/31/2014 ND Off On Notes: ND = non-detect SVE = soil vapor extraction 6/23/2014 ND Off On 9/9/ Off On 12/6/ Off On Integral Consulting Inc. Page 1 of 1
16 APPENDIX A ANALYTICAL DATA REPORTS
17 12/28/2016 Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan MN Project Name: Shoreham Yards Project #: Workorder #: Dear Mr. Brian Deering The following report includes the data for the above referenced project for sample(s) received on 12/13/2016 at Air Toxics Ltd. The data and associated QC analyzed by TO-15 are compliant with the project requirements or laboratory criteria with the exception of the deviations noted in the attached case narrative. Thank you for choosing Eurofins Air Toxics Inc. for your air analysis needs. Eurofins Air Toxics Inc. is committed to providing accurate data of the highest quality. Please feel free to contact the Project Manager: Ausha Scott at if you have any questions regarding the data in this report. Regards, Ausha Scott Project Manager Page 1 of 14
18 WORK ORDER #: Work Order Summary CLIENT: PHONE: FAX: Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan, MN DATE RECEIVED: 12/13/2016 DATE COMPLETED: 12/28/2016 BILL TO: PROJECT # CONTACT: Accounts Payable Groundwater & Environmental Services, Inc. (GES) 1350 Blair Drive, Suite A Odenton, MD P.O. # Shoreham Yards Ausha Scott RECEIPT FRACTION # NAME TEST VAC./PRES. FINAL PRESSURE 01A T-VM-4S TO "Hg 5 psi 02A Lab Blank TO-15 NA NA 03A CCV TO-15 NA NA 04A LCS TO-15 NA NA 04AA LCSD TO-15 NA NA CERTIFIED BY: DATE: 12/28/16 Technical Director Certification numbers: AZ Licensure AZ0775, NJ NELAP - CA016, NY NELAP , TX NELAP - T , UT NELAP CA , VA NELAP , WA NELAP - C935 Name of Accreditation Body: NELAP/ORELAP (Oregon Environmental Laboratory Accreditation Program) Accreditation number: CA300005, Effective date: 10/18/2016, Expiration date: 10/17/2017. Eurofins Air Toxics Inc.. certifies that the test results contained in this report meet all requirements of the NELAC standards This report shall not be reproduced, except in full, without the written approval of Eurofins Air Toxics, Inc. 180 BLUE RAVINE ROAD, SUITE B FOLSOM, CA (916) (800) FAX (916) Page 2 of 14
19 LABORATORY NARRATIVE EPA TO-15 Groundwater & Environmental Services, Inc. (GES) Workorder# One 6 Liter Summa Canister (100% Certified) sample was received on December 13, The laboratory performed analysis via EPA TO-15 using GC/MS in the full scan mode. This workorder was independently validated prior to submittal using 'USEPA National Functional Guidelines' as generally applied to the analysis of volatile organic compounds in air. A rules-based, logic driven, independent validation engine was employed to assess completeness, evaluate pass/fail of relevant project quality control requirements and verification of all quantified amounts. Receiving Notes Sample T-VM-4S was received with significant vacuum remaining in the canister. The residual canister vacuum resulted in elevated reporting limits. Analytical Notes There were no analytical discrepancies. Definition of Data Qualifying Flags Eight qualifiers may have been used on the data analysis sheets and indicates as follows: B - present in laboratory blank greater than reporting limit (background subtraction not performed). J - Estimated value. E - Exceeds instrument calibration range. S - Saturated peak. Q - Exceeds quality control limits. U - analyzed for but not detected above the reporting limit, LOD, or MDL value. See data page for project specific U-flag definition. UJ- Non-detected compound associated with low bias in the CCV N - The identification is based on presumptive evidence. File extensions may have been used on the data analysis sheets and indicates as follows: a-file was requantified b-file was quantified by a second column and detector r1-file was requantified for the purpose of reissue Page 3 of 14
20 Summary of Detected s Client Sample ID: T-VM-4S Lab ID#: A Tetrahydrofuran 1,1,1-Trichloroethane Trichloroethene Tetrachloroethene Page 4 of 14
21 File Name: p Dil. Factor: 2.77 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: T-VM-4S Lab ID#: A Date of Collection: 12/6/16 9:47:00 AM Date of Analysis: 12/21/16 06:01 PM 1.4 Not Detected 6.8 Not Detected 1.4 Not Detected 9.7 Not Detected 14 Not Detected 29 Not Detected 1.4 Not Detected 3.5 Not Detected 1.4 Not Detected 3.1 Not Detected 14 Not Detected 54 Not Detected 5.5 Not Detected 15 Not Detected 1.4 Not Detected 7.8 Not Detected 5.5 Not Detected 10 Not Detected 1.4 Not Detected 11 Not Detected 1.4 Not Detected 5.5 Not Detected 14 Not Detected 33 Not Detected 5.5 Not Detected 14 Not Detected 5.5 Not Detected 17 Not Detected 5.5 Not Detected 17 Not Detected 14 Not Detected 48 Not Detected 5.5 Not Detected 20 Not Detected 1.4 Not Detected 5.5 Not Detected 1.4 Not Detected 4.9 Not Detected 1.4 Not Detected 5.6 Not Detected 5.5 Not Detected 16 Not Detected 1.4 Not Detected 5.5 Not Detected Not Detected 6.8 Not Detected Not Detected 4.8 Not Detected 1.4 Not Detected 8.7 Not Detected 1.4 Not Detected 6.5 Not Detected 1.4 Not Detected 4.4 Not Detected 1.4 Not Detected 5.6 Not Detected 1.4 Not Detected 5.7 Not Detected Not Detected 6.4 Not Detected 5.5 Not Detected 20 Not Detected 1.4 Not Detected 9.3 Not Detected 1.4 Not Detected 6.3 Not Detected 1.4 Not Detected 5.7 Not Detected 1.4 Not Detected 5.2 Not Detected 1.4 Not Detected 6.3 Not Detected 1.4 Not Detected 7.6 Not Detected Not Detected 23 Not Detected Page 5 of 14
22 File Name: p Dil. Factor: 2.77 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: T-VM-4S Lab ID#: A Date of Collection: 12/6/16 9:47:00 AM Date of Analysis: 12/21/16 06:01 PM 1.4 Not Detected 12 Not Detected 1.4 Not Detected 11 Not Detected 1.4 Not Detected 6.4 Not Detected 1.4 Not Detected 6.0 Not Detected 1.4 Not Detected 6.0 Not Detected 1.4 Not Detected 6.0 Not Detected 1.4 Not Detected 5.9 Not Detected 1.4 Not Detected 14 Not Detected 1.4 Not Detected 6.8 Not Detected 1.4 Not Detected 9.5 Not Detected 1.4 Not Detected 6.8 Not Detected 1.4 Not Detected 6.8 Not Detected 1.4 Not Detected 6.8 Not Detected 1.4 Not Detected 6.8 Not Detected 1.4 Not Detected 8.3 Not Detected 1.4 Not Detected 8.3 Not Detected 1.4 Not Detected 7.2 Not Detected 1.4 Not Detected 8.3 Not Detected 5.5 Not Detected 41 Not Detected 5.5 Not Detected 59 Not Detected Container Type: 6 Liter Summa Canister (100% Certified) Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 6 of 14
23 File Name: p Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 12/21/16 01:22 PM 0.50 Not Detected 2.5 Not Detected 0.50 Not Detected 3.5 Not Detected 5.0 Not Detected 10 Not Detected 0.50 Not Detected 1.3 Not Detected 0.50 Not Detected 1.1 Not Detected 5.0 Not Detected 19 Not Detected 2.0 Not Detected 5.3 Not Detected 0.50 Not Detected 2.8 Not Detected 2.0 Not Detected 3.8 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.0 Not Detected 5.0 Not Detected 12 Not Detected 2.0 Not Detected 4.9 Not Detected 2.0 Not Detected 6.2 Not Detected 2.0 Not Detected 6.3 Not Detected 5.0 Not Detected 17 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.8 Not Detected 0.50 Not Detected 2.0 Not Detected 2.0 Not Detected 5.9 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.5 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 1.7 Not Detected 0.50 Not Detected 3.1 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 1.6 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 2.3 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.9 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 3.4 Not Detected 2.0 Not Detected 8.2 Not Detected Page 7 of 14
24 File Name: p Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 12/21/16 01:22 PM 0.50 Not Detected 4.2 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.1 Not Detected 0.50 Not Detected 5.2 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 2.6 Not Detected 0.50 Not Detected 3.0 Not Detected 2.0 Not Detected 15 Not Detected 2.0 Not Detected 21 Not Detected Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 8 of 14
25 Client Sample ID: CCV Lab ID#: A File Name: p Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 12/21/16 11:15 AM Page 9 of 14
26 Client Sample ID: CCV Lab ID#: A File Name: p Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 12/21/16 11:15 AM Page 10 of 14
27 Client Sample ID: LCS Lab ID#: A File Name: p Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 12/21/16 11:40 AM Page 11 of 14
28 Client Sample ID: LCS Lab ID#: A File Name: p Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 12/21/16 11:40 AM Page 12 of 14
29 Client Sample ID: LCSD Lab ID#: AA File Name: p Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 12/21/16 12:04 PM Page 13 of 14
30 Client Sample ID: LCSD Lab ID#: AA File Name: p Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 12/21/16 12:04 PM Page 14 of 14
31
32 1/4/2017 Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan MN Project Name: Shoreham Yards Project #: Workorder #: A Dear Mr. Brian Deering The following report includes the data for the above referenced project for sample(s) received on 12/19/2016 at Air Toxics Ltd. The data and associated QC analyzed by TO-15 are compliant with the project requirements or laboratory criteria with the exception of the deviations noted in the attached case narrative. Thank you for choosing Eurofins Air Toxics Inc. for your air analysis needs. Eurofins Air Toxics Inc. is committed to providing accurate data of the highest quality. Please feel free to contact the Project Manager: Ausha Scott at if you have any questions regarding the data in this report. Regards, Ausha Scott Project Manager Page 1 of 24
33 WORK ORDER #: A Work Order Summary CLIENT: PHONE: FAX: Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan, MN DATE RECEIVED: 12/19/2016 DATE COMPLETED: 01/04/2017 BILL TO: PROJECT # CONTACT: Accounts Payable Groundwater & Environmental Services, Inc. (GES) 1350 Blair Drive, Suite A Odenton, MD P.O. # /43500/220 Shoreham Yards Ausha Scott RECEIPT FRACTION # NAME TEST VAC./PRES. FINAL PRESSURE 01A Till TO "Hg 5 psi 02A Alluvium TO "Hg 5 psi 03A Lab Blank TO-15 NA NA 03B Lab Blank TO-15 NA NA 04A CCV TO-15 NA NA 04B CCV TO-15 NA NA 05A LCS TO-15 NA NA 05AA LCSD TO-15 NA NA 05B LCS TO-15 NA NA 05BB LCSD TO-15 NA NA CERTIFIED BY: DATE: 01/04/17 Technical Director Certification numbers: AZ Licensure AZ0775, NJ NELAP - CA016, NY NELAP , TX NELAP - T , UT NELAP CA , VA NELAP , WA NELAP - C935 Name of Accreditation Body: NELAP/ORELAP (Oregon Environmental Laboratory Accreditation Program) Accreditation number: CA300005, Effective date: 10/18/2016, Expiration date: 10/17/2017. Eurofins Air Toxics Inc.. certifies that the test results contained in this report meet all requirements of the NELAC standards This report shall not be reproduced, except in full, without the written approval of Eurofins Air Toxics, Inc. 180 BLUE RAVINE ROAD, SUITE B FOLSOM, CA (916) (800) FAX (916) Page 2 of 24
34 LABORATORY NARRATIVE EPA TO-15 Groundwater & Environmental Services, Inc. (GES) Workorder# A Two 6 Liter Summa Canister samples were received on December 19, The laboratory performed analysis via EPA TO-15 using GC/MS in the full scan mode. This workorder was independently validated prior to submittal using 'USEPA National Functional Guidelines' as generally applied to the analysis of volatile organic compounds in air. A rules-based, logic driven, independent validation engine was employed to assess completeness, evaluate pass/fail of relevant project quality control requirements and verification of all quantified amounts. Receiving Notes There was a significant difference (greater than 5.0" Hg) between the measured canister receipt vacuum and that which was reported on the Chain of Custody (COC) for sample Alluvium. A leak test indicated that the valve was functioning properly. Analytical Notes All Quality Control Limit exceedances and affected sample results are noted by flags. Each flag is defined at the bottom of this Case Narrative and on each Sample Result Summary page. Definition of Data Qualifying Flags Eight qualifiers may have been used on the data analysis sheets and indicates as follows: B - present in laboratory blank greater than reporting limit (background subtraction not performed). J - Estimated value. E - Exceeds instrument calibration range. S - Saturated peak. Q - Exceeds quality control limits. U - analyzed for but not detected above the reporting limit, LOD, or MDL value. See data page for project specific U-flag definition. UJ- Non-detected compound associated with low bias in the CCV N - The identification is based on presumptive evidence. File extensions may have been used on the data analysis sheets and indicates as follows: a-file was requantified b-file was quantified by a second column and detector r1-file was requantified for the purpose of reissue Page 3 of 24
35 Summary of Detected s Client Sample ID: Till Lab ID#: A-01A Freon 12 Acetone trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene 1,1,1-Trichloroethane Trichloroethene Toluene 1,1,2-Trichloroethane Tetrachloroethene Client Sample ID: Alluvium Lab ID#: A-02A Freon 12 cis-1,2-dichloroethene 1,1,1-Trichloroethane Trichloroethene 1,1,2-Trichloroethane Tetrachloroethene Page 4 of 24
36 File Name: Dil. Factor: 1.55 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Till Lab ID#: A-01A Date of Collection: 12/13/16 1:34:00 PM Date of Analysis: 12/28/16 04:30 PM Not Detected 5.4 Not Detected 7.8 Not Detected 16 Not Detected 0.78 Not Detected 2.0 Not Detected 0.78 Not Detected 1.7 Not Detected 7.8 Not Detected 30 Not Detected 3.1 Not Detected 8.2 Not Detected 0.78 Not Detected 4.4 Not Detected 3.1 Not Detected 5.8 Not Detected 0.78 Not Detected 5.9 Not Detected 0.78 Not Detected 3.1 Not Detected Not Detected 7.6 Not Detected 3.1 Not Detected 9.6 Not Detected 3.1 Not Detected 9.7 Not Detected 7.8 Not Detected 27 Not Detected 3.1 Not Detected 11 Not Detected Not Detected 2.3 Not Detected 0.78 Not Detected 3.8 Not Detected Not Detected 2.7 Not Detected 0.78 Not Detected 4.9 Not Detected 0.78 Not Detected 3.6 Not Detected 0.78 Not Detected 2.5 Not Detected 0.78 Not Detected 3.1 Not Detected 0.78 Not Detected 3.2 Not Detected Not Detected 3.6 Not Detected 3.1 Not Detected 11 Not Detected 0.78 Not Detected 5.2 Not Detected 0.78 Not Detected 3.5 Not Detected 0.78 Not Detected 3.2 Not Detected Not Detected 3.5 Not Detected Not Detected 13 Not Detected Page 5 of 24
37 File Name: Dil. Factor: 1.55 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Till Lab ID#: A-01A Date of Collection: 12/13/16 1:34:00 PM Date of Analysis: 12/28/16 04:30 PM 0.78 Not Detected 6.6 Not Detected 0.78 Not Detected 6.0 Not Detected 0.78 Not Detected 3.6 Not Detected 0.78 Not Detected 3.4 Not Detected 0.78 Not Detected 3.4 Not Detected 0.78 Not Detected 3.4 Not Detected 0.78 Not Detected 3.3 Not Detected 0.78 Not Detected 8.0 Not Detected 0.78 Not Detected 3.8 Not Detected 0.78 Not Detected 5.3 Not Detected 0.78 Not Detected 3.8 Not Detected 0.78 Not Detected 3.8 Not Detected 0.78 Not Detected 3.8 Not Detected 0.78 Not Detected 3.8 Not Detected 0.78 Not Detected 4.6 Not Detected 0.78 Not Detected 4.6 Not Detected 0.78 Not Detected 4.0 Not Detected 0.78 Not Detected 4.6 Not Detected 3.1 Not Detected 23 Not Detected 3.1 Not Detected 33 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 6 of 24
38 File Name: a Dil. Factor: 1.39 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Alluvium Lab ID#: A-02A Date of Collection: 12/14/16 11:36:00 A Date of Analysis: 12/22/16 11:29 PM Not Detected 4.8 Not Detected 7.0 Not Detected 14 Not Detected 0.70 Not Detected 1.8 Not Detected 0.70 Not Detected 1.5 Not Detected 7.0 Not Detected 27 Not Detected 2.8 Not Detected 7.3 Not Detected 0.70 Not Detected 3.9 Not Detected 2.8 Not Detected 5.2 Not Detected 0.70 Not Detected 5.3 Not Detected 0.70 Not Detected 2.8 Not Detected 7.0 Not Detected 16 Not Detected 2.8 Not Detected 6.8 Not Detected 2.8 Not Detected 8.6 Not Detected 2.8 Not Detected 8.7 Not Detected 7.0 Not Detected 24 Not Detected 2.8 Not Detected 10 Not Detected 0.70 Not Detected 2.8 Not Detected 0.70 Not Detected 2.4 Not Detected 0.70 Not Detected 2.8 Not Detected 2.8 Not Detected 8.2 Not Detected Not Detected 2.0 Not Detected 0.70 Not Detected 3.4 Not Detected Not Detected 2.4 Not Detected 0.70 Not Detected 4.4 Not Detected 0.70 Not Detected 3.2 Not Detected 0.70 Not Detected 2.2 Not Detected 0.70 Not Detected 2.8 Not Detected 0.70 Not Detected 2.8 Not Detected Not Detected 3.2 Not Detected 2.8 Not Detected 10 Not Detected 0.70 Not Detected 4.6 Not Detected 0.70 Not Detected 3.2 Not Detected 0.70 Not Detected 2.8 Not Detected 0.70 Not Detected 2.6 Not Detected 0.70 Not Detected 3.2 Not Detected Not Detected 11 Not Detected Page 7 of 24
39 File Name: a Dil. Factor: 1.39 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Alluvium Lab ID#: A-02A Date of Collection: 12/14/16 11:36:00 A Date of Analysis: 12/22/16 11:29 PM 0.70 Not Detected 5.9 Not Detected 0.70 Not Detected 5.3 Not Detected 0.70 Not Detected 3.2 Not Detected 0.70 Not Detected 3.0 Not Detected 0.70 Not Detected 3.0 Not Detected 0.70 Not Detected 3.0 Not Detected 0.70 Not Detected 3.0 Not Detected 0.70 Not Detected 7.2 Not Detected 0.70 Not Detected 3.4 Not Detected 0.70 Not Detected 4.8 Not Detected 0.70 Not Detected 3.4 Not Detected 0.70 Not Detected 3.4 Not Detected 0.70 Not Detected 3.4 Not Detected 0.70 Not Detected 3.4 Not Detected 0.70 Not Detected 4.2 Not Detected 0.70 Not Detected 4.2 Not Detected 0.70 Not Detected 3.6 Not Detected 0.70 Not Detected 4.2 Not Detected 2.8 Not Detected 21 Not Detected 2.8 Not Detected 30 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 8 of 24
40 File Name: a Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Lab Blank Lab ID#: A-03A Date of Collection: NA Date of Analysis: 12/22/16 02:31 PM 0.50 Not Detected 2.5 Not Detected 0.50 Not Detected 3.5 Not Detected 5.0 Not Detected 10 Not Detected 0.50 Not Detected 1.3 Not Detected 0.50 Not Detected 1.1 Not Detected 5.0 Not Detected 19 Not Detected 2.0 Not Detected 5.3 Not Detected 0.50 Not Detected 2.8 Not Detected 2.0 Not Detected 3.8 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.0 Not Detected 5.0 Not Detected 12 Not Detected 2.0 Not Detected 4.9 Not Detected 2.0 Not Detected 6.2 Not Detected 2.0 Not Detected 6.3 Not Detected 5.0 Not Detected 17 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.8 Not Detected 0.50 Not Detected 2.0 Not Detected 2.0 Not Detected 5.9 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.5 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 1.7 Not Detected 0.50 Not Detected 3.1 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 1.6 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 2.3 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.9 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 3.4 Not Detected 2.0 Not Detected 8.2 Not Detected Page 9 of 24
41 File Name: a Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Lab Blank Lab ID#: A-03A Date of Collection: NA Date of Analysis: 12/22/16 02:31 PM 0.50 Not Detected 4.2 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.1 Not Detected 0.50 Not Detected 5.2 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 2.6 Not Detected 0.50 Not Detected 3.0 Not Detected 2.0 Not Detected 15 Not Detected 2.0 Not Detected 21 Not Detected Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 10 of 24
42 File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Lab Blank Lab ID#: A-03B Date of Collection: NA Date of Analysis: 12/28/16 01:36 PM 0.50 Not Detected 2.5 Not Detected 0.50 Not Detected 3.5 Not Detected 5.0 Not Detected 10 Not Detected 0.50 Not Detected 1.3 Not Detected 0.50 Not Detected 1.1 Not Detected 5.0 Not Detected 19 Not Detected 2.0 Not Detected 5.3 Not Detected 0.50 Not Detected 2.8 Not Detected 2.0 Not Detected 3.8 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.0 Not Detected 5.0 Not Detected 12 Not Detected 2.0 Not Detected 4.9 Not Detected 2.0 Not Detected 6.2 Not Detected 2.0 Not Detected 6.3 Not Detected 5.0 Not Detected 17 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.8 Not Detected 0.50 Not Detected 2.0 Not Detected 2.0 Not Detected 5.9 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.5 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 1.7 Not Detected 0.50 Not Detected 3.1 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 1.6 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 2.3 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.9 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 3.4 Not Detected 2.0 Not Detected 8.2 Not Detected Page 11 of 24
43 File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Lab Blank Lab ID#: A-03B Date of Collection: NA Date of Analysis: 12/28/16 01:36 PM 0.50 Not Detected 4.2 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.1 Not Detected 0.50 Not Detected 5.2 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 2.6 Not Detected 0.50 Not Detected 3.0 Not Detected 2.0 Not Detected 15 Not Detected 2.0 Not Detected 21 Not Detected Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 12 of 24
44 Client Sample ID: CCV Lab ID#: A-04A File Name: a Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 12/22/16 10:07 AM Page 13 of 24
45 Client Sample ID: CCV Lab ID#: A-04A File Name: a Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 12/22/16 10:07 AM Page 14 of 24
46 Client Sample ID: CCV Lab ID#: A-04B File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 12/28/16 09:16 AM Page 15 of 24
47 Client Sample ID: CCV Lab ID#: A-04B File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 12/28/16 09:16 AM Page 16 of 24
48 Client Sample ID: LCS Lab ID#: A-05A File Name: a Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 12/22/16 10:32 AM Q Page 17 of 24
49 Client Sample ID: LCS Lab ID#: A-05A File Name: a Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Q = Exceeds Quality Control limits. Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 12/22/16 10:32 AM Page 18 of 24
50 Client Sample ID: LCSD Lab ID#: A-05AA File Name: a Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 12/22/16 10:57 AM Q Page 19 of 24
51 Client Sample ID: LCSD Lab ID#: A-05AA File Name: a Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Q = Exceeds Quality Control limits. Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 12/22/16 10:57 AM Page 20 of 24
52 Client Sample ID: LCS Lab ID#: A-05B File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 12/28/16 09:45 AM Q Page 21 of 24
53 Client Sample ID: LCS Lab ID#: A-05B File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Q = Exceeds Quality Control limits. Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 12/28/16 09:45 AM Page 22 of 24
54 Client Sample ID: LCSD Lab ID#: A-05BB File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 12/28/16 10:13 AM Q Page 23 of 24
55 Client Sample ID: LCSD Lab ID#: A-05BB File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Q = Exceeds Quality Control limits. Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 12/28/16 10:13 AM Page 24 of 24
56
57 1/4/2017 Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan MN Project Name: Shoreham Yards Project #: Workorder #: Dear Mr. Brian Deering The following report includes the data for the above referenced project for sample(s) received on 12/23/2016 at Air Toxics Ltd. The data and associated QC analyzed by TO-15 are compliant with the project requirements or laboratory criteria with the exception of the deviations noted in the attached case narrative. Thank you for choosing Eurofins Air Toxics Inc. for your air analysis needs. Eurofins Air Toxics Inc. is committed to providing accurate data of the highest quality. Please feel free to contact the Project Manager: Ausha Scott at if you have any questions regarding the data in this report. Regards, Ausha Scott Project Manager Page 1 of 16
58 WORK ORDER #: Work Order Summary CLIENT: PHONE: FAX: Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan, MN DATE RECEIVED: 12/23/2016 DATE COMPLETED: 01/04/2017 BILL TO: PROJECT # CONTACT: Accounts Payable Groundwater & Environmental Services, Inc. (GES) 1350 Blair Drive, Suite A Odenton, MD P.O. # /43500/220 Shoreham Yards Ausha Scott RECEIPT FRACTION # NAME TEST VAC./PRES. FINAL PRESSURE 01A Till TO "Hg 4.8 psi 02A Alluvium TO "Hg 5 psi 03A Lab Blank TO-15 NA NA 04A CCV TO-15 NA NA 05A LCS TO-15 NA NA 05AA LCSD TO-15 NA NA CERTIFIED BY: DATE: 01/04/17 Technical Director Certification numbers: AZ Licensure AZ0775, NJ NELAP - CA016, NY NELAP , TX NELAP - T , UT NELAP CA , VA NELAP , WA NELAP - C935 Name of Accreditation Body: NELAP/ORELAP (Oregon Environmental Laboratory Accreditation Program) Accreditation number: CA300005, Effective date: 10/18/2016, Expiration date: 10/17/2017. Eurofins Air Toxics Inc.. certifies that the test results contained in this report meet all requirements of the NELAC standards This report shall not be reproduced, except in full, without the written approval of Eurofins Air Toxics, Inc. 180 BLUE RAVINE ROAD, SUITE B FOLSOM, CA (916) (800) FAX (916) Page 2 of 16
59 LABORATORY NARRATIVE EPA TO-15 Groundwater & Environmental Services, Inc. (GES) Workorder# Two 6 Liter Summa Canister samples were received on December 23, The laboratory performed analysis via EPA TO-15 using GC/MS in the full scan mode. This workorder was independently validated prior to submittal using 'USEPA National Functional Guidelines' as generally applied to the analysis of volatile organic compounds in air. A rules-based, logic driven, independent validation engine was employed to assess completeness, evaluate pass/fail of relevant project quality control requirements and verification of all quantified amounts. Receiving Notes There were no receiving discrepancies. Analytical Notes There were no analytical discrepancies. Definition of Data Qualifying Flags Eight qualifiers may have been used on the data analysis sheets and indicates as follows: B - present in laboratory blank greater than reporting limit (background subtraction not performed). J - Estimated value. E - Exceeds instrument calibration range. S - Saturated peak. Q - Exceeds quality control limits. U - analyzed for but not detected above the reporting limit, LOD, or MDL value. See data page for project specific U-flag definition. UJ- Non-detected compound associated with low bias in the CCV N - The identification is based on presumptive evidence. File extensions may have been used on the data analysis sheets and indicates as follows: a-file was requantified b-file was quantified by a second column and detector r1-file was requantified for the purpose of reissue Page 3 of 16
60 Summary of Detected s Client Sample ID: Till Lab ID#: A 1,1-Dichloroethane cis-1,2-dichloroethene 1,1,1-Trichloroethane Trichloroethene 1,1,2-Trichloroethane Tetrachloroethene Client Sample ID: Alluvium Lab ID#: A Freon 12 1,1-Dichloroethane cis-1,2-dichloroethene 1,1,1-Trichloroethane Trichloroethene 1,1,2-Trichloroethane Tetrachloroethene Page 4 of 16
61 File Name: p Dil. Factor: 1.58 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Till Lab ID#: A Date of Collection: 12/20/16 12:35:00 P Date of Analysis: 1/3/17 03:25 PM 0.79 Not Detected 3.9 Not Detected 0.79 Not Detected 5.5 Not Detected 7.9 Not Detected 16 Not Detected 0.79 Not Detected 2.0 Not Detected 0.79 Not Detected 1.7 Not Detected 7.9 Not Detected 31 Not Detected 3.2 Not Detected 8.3 Not Detected 0.79 Not Detected 4.4 Not Detected 3.2 Not Detected 6.0 Not Detected 0.79 Not Detected 6.0 Not Detected 0.79 Not Detected 3.1 Not Detected 7.9 Not Detected 19 Not Detected 3.2 Not Detected 7.8 Not Detected 3.2 Not Detected 9.8 Not Detected 3.2 Not Detected 9.9 Not Detected 7.9 Not Detected 27 Not Detected 3.2 Not Detected 11 Not Detected 0.79 Not Detected 3.1 Not Detected 0.79 Not Detected 2.8 Not Detected Not Detected 9.3 Not Detected Not Detected 2.3 Not Detected 0.79 Not Detected 3.8 Not Detected Not Detected 2.7 Not Detected 0.79 Not Detected 5.0 Not Detected 0.79 Not Detected 3.7 Not Detected 0.79 Not Detected 2.5 Not Detected 0.79 Not Detected 3.2 Not Detected 0.79 Not Detected 3.2 Not Detected Not Detected 3.6 Not Detected 3.2 Not Detected 11 Not Detected 0.79 Not Detected 5.3 Not Detected 0.79 Not Detected 3.6 Not Detected 0.79 Not Detected 3.2 Not Detected 0.79 Not Detected 3.0 Not Detected 0.79 Not Detected 3.6 Not Detected Not Detected 13 Not Detected Page 5 of 16
62 File Name: p Dil. Factor: 1.58 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Till Lab ID#: A Date of Collection: 12/20/16 12:35:00 P Date of Analysis: 1/3/17 03:25 PM 0.79 Not Detected 6.7 Not Detected 0.79 Not Detected 6.1 Not Detected 0.79 Not Detected 3.6 Not Detected 0.79 Not Detected 3.4 Not Detected 0.79 Not Detected 3.4 Not Detected 0.79 Not Detected 3.4 Not Detected 0.79 Not Detected 3.4 Not Detected 0.79 Not Detected 8.2 Not Detected 0.79 Not Detected 3.9 Not Detected 0.79 Not Detected 5.4 Not Detected 0.79 Not Detected 3.9 Not Detected 0.79 Not Detected 3.9 Not Detected 0.79 Not Detected 3.9 Not Detected 0.79 Not Detected 3.9 Not Detected 0.79 Not Detected 4.8 Not Detected 0.79 Not Detected 4.8 Not Detected 0.79 Not Detected 4.1 Not Detected 0.79 Not Detected 4.7 Not Detected 3.2 Not Detected 23 Not Detected 3.2 Not Detected 34 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 6 of 16
63 File Name: p Dil. Factor: 1.59 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Alluvium Lab ID#: A Date of Collection: 12/20/16 12:39:00 P Date of Analysis: 1/3/17 03:51 PM Not Detected 5.6 Not Detected 8.0 Not Detected 16 Not Detected 0.80 Not Detected 2.0 Not Detected 0.80 Not Detected 1.8 Not Detected 8.0 Not Detected 31 Not Detected 3.2 Not Detected 8.4 Not Detected 0.80 Not Detected 4.5 Not Detected 3.2 Not Detected 6.0 Not Detected 0.80 Not Detected 6.1 Not Detected 0.80 Not Detected 3.2 Not Detected 8.0 Not Detected 19 Not Detected 3.2 Not Detected 7.8 Not Detected 3.2 Not Detected 9.9 Not Detected 3.2 Not Detected 10 Not Detected 8.0 Not Detected 28 Not Detected 3.2 Not Detected 11 Not Detected 0.80 Not Detected 3.2 Not Detected 0.80 Not Detected 2.8 Not Detected Not Detected 9.4 Not Detected Not Detected 2.3 Not Detected 0.80 Not Detected 3.9 Not Detected Not Detected 2.7 Not Detected 0.80 Not Detected 5.0 Not Detected 0.80 Not Detected 3.7 Not Detected 0.80 Not Detected 2.5 Not Detected 0.80 Not Detected 3.2 Not Detected 0.80 Not Detected 3.2 Not Detected Not Detected 3.7 Not Detected 3.2 Not Detected 11 Not Detected 0.80 Not Detected 5.3 Not Detected 0.80 Not Detected 3.6 Not Detected 0.80 Not Detected 3.2 Not Detected 0.80 Not Detected 3.0 Not Detected 0.80 Not Detected 3.6 Not Detected Not Detected 13 Not Detected Page 7 of 16
64 File Name: p Dil. Factor: 1.59 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Alluvium Lab ID#: A Date of Collection: 12/20/16 12:39:00 P Date of Analysis: 1/3/17 03:51 PM 0.80 Not Detected 6.8 Not Detected 0.80 Not Detected 6.1 Not Detected 0.80 Not Detected 3.6 Not Detected 0.80 Not Detected 3.4 Not Detected 0.80 Not Detected 3.4 Not Detected 0.80 Not Detected 3.4 Not Detected 0.80 Not Detected 3.4 Not Detected 0.80 Not Detected 8.2 Not Detected 0.80 Not Detected 3.9 Not Detected 0.80 Not Detected 5.4 Not Detected 0.80 Not Detected 3.9 Not Detected 0.80 Not Detected 3.9 Not Detected 0.80 Not Detected 3.9 Not Detected 0.80 Not Detected 3.9 Not Detected 0.80 Not Detected 4.8 Not Detected 0.80 Not Detected 4.8 Not Detected 0.80 Not Detected 4.1 Not Detected 0.80 Not Detected 4.8 Not Detected 3.2 Not Detected 24 Not Detected 3.2 Not Detected 34 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 8 of 16
65 File Name: p Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 1/3/17 12:10 PM 0.50 Not Detected 2.5 Not Detected 0.50 Not Detected 3.5 Not Detected 5.0 Not Detected 10 Not Detected 0.50 Not Detected 1.3 Not Detected 0.50 Not Detected 1.1 Not Detected 5.0 Not Detected 19 Not Detected 2.0 Not Detected 5.3 Not Detected 0.50 Not Detected 2.8 Not Detected 2.0 Not Detected 3.8 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.0 Not Detected 5.0 Not Detected 12 Not Detected 2.0 Not Detected 4.9 Not Detected 2.0 Not Detected 6.2 Not Detected 2.0 Not Detected 6.3 Not Detected 5.0 Not Detected 17 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.8 Not Detected 0.50 Not Detected 2.0 Not Detected 2.0 Not Detected 5.9 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.5 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 1.7 Not Detected 0.50 Not Detected 3.1 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 1.6 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 2.3 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.9 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 3.4 Not Detected 2.0 Not Detected 8.2 Not Detected Page 9 of 16
66 File Name: p Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 1/3/17 12:10 PM 0.50 Not Detected 4.2 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.1 Not Detected 0.50 Not Detected 5.2 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 2.6 Not Detected 0.50 Not Detected 3.0 Not Detected 2.0 Not Detected 15 Not Detected 2.0 Not Detected 21 Not Detected Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 10 of 16
67 Client Sample ID: CCV Lab ID#: A File Name: p Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/3/17 09:41 AM Page 11 of 16
68 Client Sample ID: CCV Lab ID#: A File Name: p Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/3/17 09:41 AM Page 12 of 16
69 Client Sample ID: LCS Lab ID#: A File Name: p Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/3/17 10:05 AM Page 13 of 16
70 Client Sample ID: LCS Lab ID#: A File Name: p Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/3/17 10:05 AM Page 14 of 16
71 Client Sample ID: LCSD Lab ID#: AA File Name: p Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/3/17 10:30 AM Page 15 of 16
72 Client Sample ID: LCSD Lab ID#: AA File Name: p Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/3/17 10:30 AM Page 16 of 16
73 1/10/2017 Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan MN Project Name: Shoreham Yards Project #: Workorder #: Dear Mr. Brian Deering The following report includes the data for the above referenced project for sample(s) received on 12/23/2016 at Air Toxics Ltd. The data and associated QC analyzed by TO-15 are compliant with the project requirements or laboratory criteria with the exception of the deviations noted in the attached case narrative. Thank you for choosing Eurofins Air Toxics Inc. for your air analysis needs. Eurofins Air Toxics Inc. is committed to providing accurate data of the highest quality. Please feel free to contact the Project Manager: Ausha Scott at if you have any questions regarding the data in this report. Regards, Ausha Scott Project Manager Page 1 of 16
74 WORK ORDER #: Work Order Summary CLIENT: PHONE: FAX: Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan, MN DATE RECEIVED: 12/23/2016 DATE COMPLETED: 01/10/2017 BILL TO: PROJECT # CONTACT: Accounts Payable Groundwater & Environmental Services, Inc. (GES) 1350 Blair Drive, Suite A Odenton, MD P.O. # /43500/220 Shoreham Yards Ausha Scott RECEIPT FRACTION # NAME TEST VAC./PRES. FINAL PRESSURE 01A Till TO "Hg 4.8 psi 02A Alluvium TO "Hg 5 psi 03A Lab Blank TO-15 NA NA 04A CCV TO-15 NA NA 05A LCS TO-15 NA NA 05AA LCSD TO-15 NA NA CERTIFIED BY: DATE: 01/10/17 Technical Director Certification numbers: AZ Licensure AZ0775, NJ NELAP - CA016, NY NELAP , TX NELAP - T , UT NELAP CA , VA NELAP , WA NELAP - C935 Name of Accreditation Body: NELAP/ORELAP (Oregon Environmental Laboratory Accreditation Program) Accreditation number: CA300005, Effective date: 10/18/2016, Expiration date: 10/17/2017. Eurofins Air Toxics Inc.. certifies that the test results contained in this report meet all requirements of the NELAC standards This report shall not be reproduced, except in full, without the written approval of Eurofins Air Toxics, Inc. 180 BLUE RAVINE ROAD, SUITE B FOLSOM, CA (916) (800) FAX (916) Page 2 of 16
75 LABORATORY NARRATIVE EPA TO-15 Groundwater & Environmental Services, Inc. (GES) Workorder# Two 6 Liter Summa Canister samples were received on December 23, The laboratory performed analysis via EPA TO-15 using GC/MS in the full scan mode. This workorder was independently validated prior to submittal using 'USEPA National Functional Guidelines' as generally applied to the analysis of volatile organic compounds in air. A rules-based, logic driven, independent validation engine was employed to assess completeness, evaluate pass/fail of relevant project quality control requirements and verification of all quantified amounts. Receiving Notes There were no receiving discrepancies. Analytical Notes There were no analytical discrepancies. Definition of Data Qualifying Flags Eight qualifiers may have been used on the data analysis sheets and indicates as follows: B - present in laboratory blank greater than reporting limit (background subtraction not performed). J - Estimated value. E - Exceeds instrument calibration range. S - Saturated peak. Q - Exceeds quality control limits. U - analyzed for but not detected above the reporting limit, LOD, or MDL value. See data page for project specific U-flag definition. UJ- Non-detected compound associated with low bias in the CCV N - The identification is based on presumptive evidence. File extensions may have been used on the data analysis sheets and indicates as follows: a-file was requantified b-file was quantified by a second column and detector r1-file was requantified for the purpose of reissue Page 3 of 16
76 Summary of Detected s Client Sample ID: Till Lab ID#: A cis-1,2-dichloroethene 1,1,1-Trichloroethane Trichloroethene 1,1,2-Trichloroethane Tetrachloroethene Client Sample ID: Alluvium Lab ID#: A Freon 12 Ethanol 2-Propanol 1,1-Dichloroethane cis-1,2-dichloroethene 1,1,1-Trichloroethane Cyclohexane Trichloroethene 1,1,2-Trichloroethane Tetrachloroethene Page 4 of 16
77 File Name: p Dil. Factor: 1.62 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Till Lab ID#: A Date of Collection: 12/21/16 10:32:00 A Date of Analysis: 1/3/17 10:13 PM 0.81 Not Detected 4.0 Not Detected 0.81 Not Detected 5.7 Not Detected 8.1 Not Detected 17 Not Detected 0.81 Not Detected 2.1 Not Detected 0.81 Not Detected 1.8 Not Detected 8.1 Not Detected 31 Not Detected 3.2 Not Detected 8.5 Not Detected 0.81 Not Detected 4.6 Not Detected 3.2 Not Detected 6.1 Not Detected 0.81 Not Detected 6.2 Not Detected 0.81 Not Detected 3.2 Not Detected 8.1 Not Detected 19 Not Detected 3.2 Not Detected 8.0 Not Detected 3.2 Not Detected 10 Not Detected 3.2 Not Detected 10 Not Detected 8.1 Not Detected 28 Not Detected 3.2 Not Detected 12 Not Detected 0.81 Not Detected 3.2 Not Detected 0.81 Not Detected 2.8 Not Detected 0.81 Not Detected 3.3 Not Detected 3.2 Not Detected 9.6 Not Detected Not Detected 2.4 Not Detected 0.81 Not Detected 4.0 Not Detected Not Detected 2.8 Not Detected 0.81 Not Detected 5.1 Not Detected 0.81 Not Detected 3.8 Not Detected 0.81 Not Detected 2.6 Not Detected 0.81 Not Detected 3.3 Not Detected 0.81 Not Detected 3.3 Not Detected Not Detected 3.7 Not Detected 3.2 Not Detected 12 Not Detected 0.81 Not Detected 5.4 Not Detected 0.81 Not Detected 3.7 Not Detected 0.81 Not Detected 3.3 Not Detected 0.81 Not Detected 3.0 Not Detected 0.81 Not Detected 3.7 Not Detected Not Detected 13 Not Detected Page 5 of 16
78 File Name: p Dil. Factor: 1.62 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Till Lab ID#: A Date of Collection: 12/21/16 10:32:00 A Date of Analysis: 1/3/17 10:13 PM 0.81 Not Detected 6.9 Not Detected 0.81 Not Detected 6.2 Not Detected 0.81 Not Detected 3.7 Not Detected 0.81 Not Detected 3.5 Not Detected 0.81 Not Detected 3.5 Not Detected 0.81 Not Detected 3.5 Not Detected 0.81 Not Detected 3.4 Not Detected 0.81 Not Detected 8.4 Not Detected 0.81 Not Detected 4.0 Not Detected 0.81 Not Detected 5.6 Not Detected 0.81 Not Detected 4.0 Not Detected 0.81 Not Detected 4.0 Not Detected 0.81 Not Detected 4.0 Not Detected 0.81 Not Detected 4.0 Not Detected 0.81 Not Detected 4.9 Not Detected 0.81 Not Detected 4.9 Not Detected 0.81 Not Detected 4.2 Not Detected 0.81 Not Detected 4.9 Not Detected 3.2 Not Detected 24 Not Detected 3.2 Not Detected 34 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 6 of 16
79 File Name: p Dil. Factor: 1.61 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Alluvium Lab ID#: A Date of Collection: 12/21/16 10:38:00 A Date of Analysis: 1/3/17 10:39 PM Not Detected 5.6 Not Detected 8.0 Not Detected 17 Not Detected 0.80 Not Detected 2.0 Not Detected 0.80 Not Detected 1.8 Not Detected 8.0 Not Detected 31 Not Detected 3.2 Not Detected 8.5 Not Detected 0.80 Not Detected 4.5 Not Detected Not Detected 6.2 Not Detected 0.80 Not Detected 3.2 Not Detected 8.0 Not Detected 19 Not Detected Not Detected 10 Not Detected 3.2 Not Detected 10 Not Detected 8.0 Not Detected 28 Not Detected 3.2 Not Detected 12 Not Detected 0.80 Not Detected 3.2 Not Detected 0.80 Not Detected 2.8 Not Detected Not Detected 9.5 Not Detected Not Detected 2.4 Not Detected 0.80 Not Detected 3.9 Not Detected Not Detected 5.1 Not Detected 0.80 Not Detected 3.8 Not Detected 0.80 Not Detected 2.6 Not Detected 0.80 Not Detected 3.2 Not Detected 0.80 Not Detected 3.3 Not Detected Not Detected 3.7 Not Detected 3.2 Not Detected 12 Not Detected 0.80 Not Detected 5.4 Not Detected 0.80 Not Detected 3.6 Not Detected 0.80 Not Detected 3.3 Not Detected 0.80 Not Detected 3.0 Not Detected 0.80 Not Detected 3.6 Not Detected Not Detected 13 Not Detected Page 7 of 16
80 File Name: p Dil. Factor: 1.61 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Alluvium Lab ID#: A Date of Collection: 12/21/16 10:38:00 A Date of Analysis: 1/3/17 10:39 PM 0.80 Not Detected 6.8 Not Detected 0.80 Not Detected 6.2 Not Detected 0.80 Not Detected 3.7 Not Detected 0.80 Not Detected 3.5 Not Detected 0.80 Not Detected 3.5 Not Detected 0.80 Not Detected 3.5 Not Detected 0.80 Not Detected 3.4 Not Detected 0.80 Not Detected 8.3 Not Detected 0.80 Not Detected 4.0 Not Detected 0.80 Not Detected 5.5 Not Detected 0.80 Not Detected 4.0 Not Detected 0.80 Not Detected 4.0 Not Detected 0.80 Not Detected 4.0 Not Detected 0.80 Not Detected 4.0 Not Detected 0.80 Not Detected 4.8 Not Detected 0.80 Not Detected 4.8 Not Detected 0.80 Not Detected 4.2 Not Detected 0.80 Not Detected 4.8 Not Detected 3.2 Not Detected 24 Not Detected 3.2 Not Detected 34 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 8 of 16
81 File Name: p Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 1/3/17 12:10 PM 0.50 Not Detected 2.5 Not Detected 0.50 Not Detected 3.5 Not Detected 5.0 Not Detected 10 Not Detected 0.50 Not Detected 1.3 Not Detected 0.50 Not Detected 1.1 Not Detected 5.0 Not Detected 19 Not Detected 2.0 Not Detected 5.3 Not Detected 0.50 Not Detected 2.8 Not Detected 2.0 Not Detected 3.8 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.0 Not Detected 5.0 Not Detected 12 Not Detected 2.0 Not Detected 4.9 Not Detected 2.0 Not Detected 6.2 Not Detected 2.0 Not Detected 6.3 Not Detected 5.0 Not Detected 17 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.8 Not Detected 0.50 Not Detected 2.0 Not Detected 2.0 Not Detected 5.9 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.5 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 1.7 Not Detected 0.50 Not Detected 3.1 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 1.6 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 2.3 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.9 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 3.4 Not Detected 2.0 Not Detected 8.2 Not Detected Page 9 of 16
82 File Name: p Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 1/3/17 12:10 PM 0.50 Not Detected 4.2 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.1 Not Detected 0.50 Not Detected 5.2 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 2.6 Not Detected 0.50 Not Detected 3.0 Not Detected 2.0 Not Detected 15 Not Detected 2.0 Not Detected 21 Not Detected Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 10 of 16
83 Client Sample ID: CCV Lab ID#: A File Name: p Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/3/17 09:41 AM Page 11 of 16
84 Client Sample ID: CCV Lab ID#: A File Name: p Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/3/17 09:41 AM Page 12 of 16
85 Client Sample ID: LCS Lab ID#: A File Name: p Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/3/17 10:05 AM Page 13 of 16
86 Client Sample ID: LCS Lab ID#: A File Name: p Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/3/17 10:05 AM Page 14 of 16
87 Client Sample ID: LCSD Lab ID#: AA File Name: p Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/3/17 10:30 AM Page 15 of 16
88 Client Sample ID: LCSD Lab ID#: AA File Name: p Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/3/17 10:30 AM Page 16 of 16
89
90
91 1/11/2017 Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan MN Project Name: Shoreham Yards Project #: Workorder #: Dear Mr. Brian Deering The following report includes the data for the above referenced project for sample(s) received on 12/30/2016 at Air Toxics Ltd. The data and associated QC analyzed by TO-15 are compliant with the project requirements or laboratory criteria with the exception of the deviations noted in the attached case narrative. Thank you for choosing Eurofins Air Toxics Inc. for your air analysis needs. Eurofins Air Toxics Inc. is committed to providing accurate data of the highest quality. Please feel free to contact the Project Manager: Ausha Scott at if you have any questions regarding the data in this report. Regards, Ausha Scott Project Manager Page 1 of 16
92 WORK ORDER #: Work Order Summary CLIENT: PHONE: FAX: Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan, MN DATE RECEIVED: 12/30/2016 DATE COMPLETED: 01/11/2017 BILL TO: PROJECT # CONTACT: Accounts Payable Groundwater & Environmental Services, Inc. (GES) 1350 Blair Drive, Suite A Odenton, MD P.O. # /43500/220 Shoreham Yards Ausha Scott RECEIPT FRACTION # NAME TEST VAC./PRES. FINAL PRESSURE 01A Till TO "Hg 5.1 psi 02A Alluvium TO "Hg 5.1 psi 03A Lab Blank TO-15 NA NA 04A CCV TO-15 NA NA 05A LCS TO-15 NA NA 05AA LCSD TO-15 NA NA CERTIFIED BY: DATE: 01/11/17 Technical Director Certification numbers: AZ Licensure AZ0775, NJ NELAP - CA016, NY NELAP , TX NELAP - T , UT NELAP CA , VA NELAP , WA NELAP - C935 Name of Accreditation Body: NELAP/ORELAP (Oregon Environmental Laboratory Accreditation Program) Accreditation number: CA300005, Effective date: 10/18/2016, Expiration date: 10/17/2017. Eurofins Air Toxics Inc.. certifies that the test results contained in this report meet all requirements of the NELAC standards This report shall not be reproduced, except in full, without the written approval of Eurofins Air Toxics, Inc. 180 BLUE RAVINE ROAD, SUITE B FOLSOM, CA (916) (800) FAX (916) Page 2 of 16
93 LABORATORY NARRATIVE EPA TO-15 Groundwater & Environmental Services, Inc. (GES) Workorder# Two 6 Liter Summa Canister samples were received on December 30, The laboratory performed analysis via EPA TO-15 using GC/MS in the full scan mode. This workorder was independently validated prior to submittal using 'USEPA National Functional Guidelines' as generally applied to the analysis of volatile organic compounds in air. A rules-based, logic driven, independent validation engine was employed to assess completeness, evaluate pass/fail of relevant project quality control requirements and verification of all quantified amounts. Receiving Notes There were no receiving discrepancies. Analytical Notes There were no analytical discrepancies. Definition of Data Qualifying Flags Eight qualifiers may have been used on the data analysis sheets and indicates as follows: B - present in laboratory blank greater than reporting limit (background subtraction not performed). J - Estimated value. E - Exceeds instrument calibration range. S - Saturated peak. Q - Exceeds quality control limits. U - analyzed for but not detected above the reporting limit, LOD, or MDL value. See data page for project specific U-flag definition. UJ- Non-detected compound associated with low bias in the CCV N - The identification is based on presumptive evidence. File extensions may have been used on the data analysis sheets and indicates as follows: a-file was requantified b-file was quantified by a second column and detector r1-file was requantified for the purpose of reissue Page 3 of 16
94 Summary of Detected s Client Sample ID: Till Lab ID#: A Ethanol Acetone 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene 1,1,1-Trichloroethane Trichloroethene 1,1,2-Trichloroethane Tetrachloroethene Client Sample ID: Alluvium Lab ID#: A Freon 12 1,1-Dichloroethane cis-1,2-dichloroethene 1,1,1-Trichloroethane Trichloroethene 1,1,2-Trichloroethane Tetrachloroethene Page 4 of 16
95 File Name: p Dil. Factor: 1.68 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Till Lab ID#: A Date of Collection: 12/23/16 10:10:00 A Date of Analysis: 1/9/17 03:51 PM 0.84 Not Detected 4.2 Not Detected 0.84 Not Detected 5.9 Not Detected 8.4 Not Detected 17 Not Detected 0.84 Not Detected 2.1 Not Detected 0.84 Not Detected 1.8 Not Detected 8.4 Not Detected 33 Not Detected 3.4 Not Detected 8.9 Not Detected 0.84 Not Detected 4.7 Not Detected Not Detected 6.4 Not Detected 0.84 Not Detected 3.3 Not Detected Not Detected 8.2 Not Detected 3.4 Not Detected 10 Not Detected 3.4 Not Detected 10 Not Detected 8.4 Not Detected 29 Not Detected 3.4 Not Detected 12 Not Detected 0.84 Not Detected 3.3 Not Detected 0.84 Not Detected 3.0 Not Detected 0.84 Not Detected 3.4 Not Detected Not Detected 2.5 Not Detected 0.84 Not Detected 4.1 Not Detected Not Detected 2.9 Not Detected 0.84 Not Detected 5.3 Not Detected 0.84 Not Detected 3.9 Not Detected 0.84 Not Detected 2.7 Not Detected 0.84 Not Detected 3.4 Not Detected 0.84 Not Detected 3.4 Not Detected Not Detected 3.9 Not Detected 3.4 Not Detected 12 Not Detected 0.84 Not Detected 5.6 Not Detected 0.84 Not Detected 3.8 Not Detected 0.84 Not Detected 3.4 Not Detected 0.84 Not Detected 3.2 Not Detected 0.84 Not Detected 3.8 Not Detected Not Detected 14 Not Detected Page 5 of 16
96 File Name: p Dil. Factor: 1.68 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Till Lab ID#: A Date of Collection: 12/23/16 10:10:00 A Date of Analysis: 1/9/17 03:51 PM 0.84 Not Detected 7.2 Not Detected 0.84 Not Detected 6.4 Not Detected 0.84 Not Detected 3.9 Not Detected 0.84 Not Detected 3.6 Not Detected 0.84 Not Detected 3.6 Not Detected 0.84 Not Detected 3.6 Not Detected 0.84 Not Detected 3.6 Not Detected 0.84 Not Detected 8.7 Not Detected 0.84 Not Detected 4.1 Not Detected 0.84 Not Detected 5.8 Not Detected 0.84 Not Detected 4.1 Not Detected 0.84 Not Detected 4.1 Not Detected 0.84 Not Detected 4.1 Not Detected 0.84 Not Detected 4.1 Not Detected 0.84 Not Detected 5.0 Not Detected 0.84 Not Detected 5.0 Not Detected 0.84 Not Detected 4.3 Not Detected 0.84 Not Detected 5.0 Not Detected 3.4 Not Detected 25 Not Detected 3.4 Not Detected 36 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 6 of 16
97 File Name: p Dil. Factor: 1.62 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Alluvium Lab ID#: A Date of Collection: 12/23/16 10:17:00 A Date of Analysis: 1/9/17 04:17 PM Not Detected 5.7 Not Detected 8.1 Not Detected 17 Not Detected 0.81 Not Detected 2.1 Not Detected 0.81 Not Detected 1.8 Not Detected 8.1 Not Detected 31 Not Detected 3.2 Not Detected 8.5 Not Detected 0.81 Not Detected 4.6 Not Detected 3.2 Not Detected 6.1 Not Detected 0.81 Not Detected 6.2 Not Detected 0.81 Not Detected 3.2 Not Detected 8.1 Not Detected 19 Not Detected 3.2 Not Detected 8.0 Not Detected 3.2 Not Detected 10 Not Detected 3.2 Not Detected 10 Not Detected 8.1 Not Detected 28 Not Detected 3.2 Not Detected 12 Not Detected 0.81 Not Detected 3.2 Not Detected 0.81 Not Detected 2.8 Not Detected Not Detected 9.6 Not Detected Not Detected 2.4 Not Detected 0.81 Not Detected 4.0 Not Detected Not Detected 2.8 Not Detected 0.81 Not Detected 5.1 Not Detected 0.81 Not Detected 3.8 Not Detected 0.81 Not Detected 2.6 Not Detected 0.81 Not Detected 3.3 Not Detected 0.81 Not Detected 3.3 Not Detected Not Detected 3.7 Not Detected 3.2 Not Detected 12 Not Detected 0.81 Not Detected 5.4 Not Detected 0.81 Not Detected 3.7 Not Detected 0.81 Not Detected 3.3 Not Detected 0.81 Not Detected 3.0 Not Detected 0.81 Not Detected 3.7 Not Detected Not Detected 13 Not Detected Page 7 of 16
98 File Name: p Dil. Factor: 1.62 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Alluvium Lab ID#: A Date of Collection: 12/23/16 10:17:00 A Date of Analysis: 1/9/17 04:17 PM 0.81 Not Detected 6.9 Not Detected 0.81 Not Detected 6.2 Not Detected 0.81 Not Detected 3.7 Not Detected 0.81 Not Detected 3.5 Not Detected 0.81 Not Detected 3.5 Not Detected 0.81 Not Detected 3.5 Not Detected 0.81 Not Detected 3.4 Not Detected 0.81 Not Detected 8.4 Not Detected 0.81 Not Detected 4.0 Not Detected 0.81 Not Detected 5.6 Not Detected 0.81 Not Detected 4.0 Not Detected 0.81 Not Detected 4.0 Not Detected 0.81 Not Detected 4.0 Not Detected 0.81 Not Detected 4.0 Not Detected 0.81 Not Detected 4.9 Not Detected 0.81 Not Detected 4.9 Not Detected 0.81 Not Detected 4.2 Not Detected 0.81 Not Detected 4.9 Not Detected 3.2 Not Detected 24 Not Detected 3.2 Not Detected 34 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 8 of 16
99 File Name: p Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 1/9/17 01:43 PM 0.50 Not Detected 2.5 Not Detected 0.50 Not Detected 3.5 Not Detected 5.0 Not Detected 10 Not Detected 0.50 Not Detected 1.3 Not Detected 0.50 Not Detected 1.1 Not Detected 5.0 Not Detected 19 Not Detected 2.0 Not Detected 5.3 Not Detected 0.50 Not Detected 2.8 Not Detected 2.0 Not Detected 3.8 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.0 Not Detected 5.0 Not Detected 12 Not Detected 2.0 Not Detected 4.9 Not Detected 2.0 Not Detected 6.2 Not Detected 2.0 Not Detected 6.3 Not Detected 5.0 Not Detected 17 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.8 Not Detected 0.50 Not Detected 2.0 Not Detected 2.0 Not Detected 5.9 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.5 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 1.7 Not Detected 0.50 Not Detected 3.1 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 1.6 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 2.3 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.9 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 3.4 Not Detected 2.0 Not Detected 8.2 Not Detected Page 9 of 16
100 File Name: p Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 1/9/17 01:43 PM 0.50 Not Detected 4.2 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.1 Not Detected 0.50 Not Detected 5.2 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 2.6 Not Detected 0.50 Not Detected 3.0 Not Detected 2.0 Not Detected 15 Not Detected 2.0 Not Detected 21 Not Detected Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 10 of 16
101 Client Sample ID: CCV Lab ID#: A File Name: p Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/9/17 10:54 AM Page 11 of 16
102 Client Sample ID: CCV Lab ID#: A File Name: p Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/9/17 10:54 AM Page 12 of 16
103 Client Sample ID: LCS Lab ID#: A File Name: p Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/9/17 11:20 AM Page 13 of 16
104 Client Sample ID: LCS Lab ID#: A File Name: p Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/9/17 11:20 AM Page 14 of 16
105 Client Sample ID: LCSD Lab ID#: AA File Name: p Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/9/17 11:46 AM Page 15 of 16
106 Client Sample ID: LCSD Lab ID#: AA File Name: p Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/9/17 11:46 AM Page 16 of 16
107
108 1/11/2017 Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan MN Project Name: Shoreham Yards Project #: Workorder #: Dear Mr. Brian Deering The following report includes the data for the above referenced project for sample(s) received on 12/30/2016 at Air Toxics Ltd. The data and associated QC analyzed by TO-15 are compliant with the project requirements or laboratory criteria with the exception of the deviations noted in the attached case narrative. Thank you for choosing Eurofins Air Toxics Inc. for your air analysis needs. Eurofins Air Toxics Inc. is committed to providing accurate data of the highest quality. Please feel free to contact the Project Manager: Ausha Scott at if you have any questions regarding the data in this report. Regards, Ausha Scott Project Manager Page 1 of 16
109 WORK ORDER #: Work Order Summary CLIENT: PHONE: FAX: Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan, MN DATE RECEIVED: 12/30/2016 DATE COMPLETED: 01/11/2017 BILL TO: PROJECT # CONTACT: Accounts Payable Groundwater & Environmental Services, Inc. (GES) 1350 Blair Drive, Suite A Odenton, MD P.O. # /43500/220 Shoreham Yards Ausha Scott RECEIPT FRACTION # NAME TEST VAC./PRES. FINAL PRESSURE 01A Till TO "Hg 5 psi 02A Alluvium TO "Hg 5 psi 03A Lab Blank TO-15 NA NA 04A CCV TO-15 NA NA 05A LCS TO-15 NA NA 05AA LCSD TO-15 NA NA CERTIFIED BY: DATE: 01/11/17 Technical Director Certification numbers: AZ Licensure AZ0775, NJ NELAP - CA016, NY NELAP , TX NELAP - T , UT NELAP CA , VA NELAP , WA NELAP - C935 Name of Accreditation Body: NELAP/ORELAP (Oregon Environmental Laboratory Accreditation Program) Accreditation number: CA300005, Effective date: 10/18/2016, Expiration date: 10/17/2017. Eurofins Air Toxics Inc.. certifies that the test results contained in this report meet all requirements of the NELAC standards This report shall not be reproduced, except in full, without the written approval of Eurofins Air Toxics, Inc. 180 BLUE RAVINE ROAD, SUITE B FOLSOM, CA (916) (800) FAX (916) Page 2 of 16
110 LABORATORY NARRATIVE EPA TO-15 Groundwater & Environmental Services, Inc. (GES) Workorder# Two 6 Liter Summa Canister samples were received on December 30, The laboratory performed analysis via EPA TO-15 using GC/MS in the full scan mode. This workorder was independently validated prior to submittal using 'USEPA National Functional Guidelines' as generally applied to the analysis of volatile organic compounds in air. A rules-based, logic driven, independent validation engine was employed to assess completeness, evaluate pass/fail of relevant project quality control requirements and verification of all quantified amounts. Receiving Notes There were no receiving discrepancies. Analytical Notes There were no analytical discrepancies. Definition of Data Qualifying Flags Eight qualifiers may have been used on the data analysis sheets and indicates as follows: B - present in laboratory blank greater than reporting limit (background subtraction not performed). J - Estimated value. E - Exceeds instrument calibration range. S - Saturated peak. Q - Exceeds quality control limits. U - analyzed for but not detected above the reporting limit, LOD, or MDL value. See data page for project specific U-flag definition. UJ- Non-detected compound associated with low bias in the CCV N - The identification is based on presumptive evidence. File extensions may have been used on the data analysis sheets and indicates as follows: a-file was requantified b-file was quantified by a second column and detector r1-file was requantified for the purpose of reissue Page 3 of 16
111 Summary of Detected s Client Sample ID: Till Lab ID#: A cis-1,2-dichloroethene 1,1,1-Trichloroethane Trichloroethene 1,1,2-Trichloroethane Tetrachloroethene Client Sample ID: Alluvium Lab ID#: A Freon 12 1,1-Dichloroethane cis-1,2-dichloroethene 1,1,1-Trichloroethane Trichloroethene 1,1,2-Trichloroethane Tetrachloroethene Page 4 of 16
112 File Name: p Dil. Factor: 1.67 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Till Lab ID#: A Date of Collection: 12/27/16 11:46:00 A Date of Analysis: 1/5/17 10:29 PM 0.84 Not Detected 4.1 Not Detected 0.84 Not Detected 5.8 Not Detected 8.4 Not Detected 17 Not Detected 0.84 Not Detected 2.1 Not Detected 0.84 Not Detected 1.8 Not Detected 8.4 Not Detected 32 Not Detected 3.3 Not Detected 8.8 Not Detected 0.84 Not Detected 4.7 Not Detected 3.3 Not Detected 6.3 Not Detected 0.84 Not Detected 6.4 Not Detected 0.84 Not Detected 3.3 Not Detected 8.4 Not Detected 20 Not Detected 3.3 Not Detected 8.2 Not Detected 3.3 Not Detected 10 Not Detected 3.3 Not Detected 10 Not Detected 8.4 Not Detected 29 Not Detected 3.3 Not Detected 12 Not Detected 0.84 Not Detected 3.3 Not Detected 0.84 Not Detected 2.9 Not Detected 0.84 Not Detected 3.4 Not Detected 3.3 Not Detected 9.8 Not Detected Not Detected 2.5 Not Detected 0.84 Not Detected 4.1 Not Detected Not Detected 2.9 Not Detected 0.84 Not Detected 5.2 Not Detected 0.84 Not Detected 3.9 Not Detected 0.84 Not Detected 2.7 Not Detected 0.84 Not Detected 3.4 Not Detected 0.84 Not Detected 3.4 Not Detected Not Detected 3.8 Not Detected 3.3 Not Detected 12 Not Detected 0.84 Not Detected 5.6 Not Detected 0.84 Not Detected 3.8 Not Detected 0.84 Not Detected 3.4 Not Detected 0.84 Not Detected 3.1 Not Detected 0.84 Not Detected 3.8 Not Detected Not Detected 14 Not Detected Page 5 of 16
113 File Name: p Dil. Factor: 1.67 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Till Lab ID#: A Date of Collection: 12/27/16 11:46:00 A Date of Analysis: 1/5/17 10:29 PM 0.84 Not Detected 7.1 Not Detected 0.84 Not Detected 6.4 Not Detected 0.84 Not Detected 3.8 Not Detected 0.84 Not Detected 3.6 Not Detected 0.84 Not Detected 3.6 Not Detected 0.84 Not Detected 3.6 Not Detected 0.84 Not Detected 3.6 Not Detected 0.84 Not Detected 8.6 Not Detected 0.84 Not Detected 4.1 Not Detected 0.84 Not Detected 5.7 Not Detected 0.84 Not Detected 4.1 Not Detected 0.84 Not Detected 4.1 Not Detected 0.84 Not Detected 4.1 Not Detected 0.84 Not Detected 4.1 Not Detected 0.84 Not Detected 5.0 Not Detected 0.84 Not Detected 5.0 Not Detected 0.84 Not Detected 4.3 Not Detected 0.84 Not Detected 5.0 Not Detected 3.3 Not Detected 25 Not Detected 3.3 Not Detected 36 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 6 of 16
114 File Name: p Dil. Factor: 1.52 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Alluvium Lab ID#: A Date of Collection: 12/27/16 11:53:00 A Date of Analysis: 1/5/17 10:55 PM Not Detected 5.3 Not Detected 7.6 Not Detected 16 Not Detected 0.76 Not Detected 1.9 Not Detected 0.76 Not Detected 1.7 Not Detected 7.6 Not Detected 30 Not Detected 3.0 Not Detected 8.0 Not Detected 0.76 Not Detected 4.3 Not Detected 3.0 Not Detected 5.7 Not Detected 0.76 Not Detected 5.8 Not Detected 0.76 Not Detected 3.0 Not Detected 7.6 Not Detected 18 Not Detected 3.0 Not Detected 7.5 Not Detected 3.0 Not Detected 9.5 Not Detected 3.0 Not Detected 9.5 Not Detected 7.6 Not Detected 26 Not Detected 3.0 Not Detected 11 Not Detected 0.76 Not Detected 3.0 Not Detected 0.76 Not Detected 2.7 Not Detected Not Detected 9.0 Not Detected Not Detected 2.2 Not Detected 0.76 Not Detected 3.7 Not Detected Not Detected 2.6 Not Detected 0.76 Not Detected 4.8 Not Detected 0.76 Not Detected 3.6 Not Detected 0.76 Not Detected 2.4 Not Detected 0.76 Not Detected 3.1 Not Detected 0.76 Not Detected 3.1 Not Detected Not Detected 3.5 Not Detected 3.0 Not Detected 11 Not Detected 0.76 Not Detected 5.1 Not Detected 0.76 Not Detected 3.4 Not Detected 0.76 Not Detected 3.1 Not Detected 0.76 Not Detected 2.9 Not Detected 0.76 Not Detected 3.4 Not Detected Not Detected 12 Not Detected Page 7 of 16
115 File Name: p Dil. Factor: 1.52 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Alluvium Lab ID#: A Date of Collection: 12/27/16 11:53:00 A Date of Analysis: 1/5/17 10:55 PM 0.76 Not Detected 6.5 Not Detected 0.76 Not Detected 5.8 Not Detected 0.76 Not Detected 3.5 Not Detected 0.76 Not Detected 3.3 Not Detected 0.76 Not Detected 3.3 Not Detected 0.76 Not Detected 3.3 Not Detected 0.76 Not Detected 3.2 Not Detected 0.76 Not Detected 7.8 Not Detected 0.76 Not Detected 3.7 Not Detected 0.76 Not Detected 5.2 Not Detected 0.76 Not Detected 3.7 Not Detected 0.76 Not Detected 3.7 Not Detected 0.76 Not Detected 3.7 Not Detected 0.76 Not Detected 3.7 Not Detected 0.76 Not Detected 4.6 Not Detected 0.76 Not Detected 4.6 Not Detected 0.76 Not Detected 3.9 Not Detected 0.76 Not Detected 4.6 Not Detected 3.0 Not Detected 22 Not Detected 3.0 Not Detected 32 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 8 of 16
116 File Name: p Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 1/5/17 01:59 PM 0.50 Not Detected 2.5 Not Detected 0.50 Not Detected 3.5 Not Detected 5.0 Not Detected 10 Not Detected 0.50 Not Detected 1.3 Not Detected 0.50 Not Detected 1.1 Not Detected 5.0 Not Detected 19 Not Detected 2.0 Not Detected 5.3 Not Detected 0.50 Not Detected 2.8 Not Detected 2.0 Not Detected 3.8 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.0 Not Detected 5.0 Not Detected 12 Not Detected 2.0 Not Detected 4.9 Not Detected 2.0 Not Detected 6.2 Not Detected 2.0 Not Detected 6.3 Not Detected 5.0 Not Detected 17 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.8 Not Detected 0.50 Not Detected 2.0 Not Detected 2.0 Not Detected 5.9 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.5 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 1.7 Not Detected 0.50 Not Detected 3.1 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 1.6 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 2.3 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.9 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 3.4 Not Detected 2.0 Not Detected 8.2 Not Detected Page 9 of 16
117 File Name: p Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 1/5/17 01:59 PM 0.50 Not Detected 4.2 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.1 Not Detected 0.50 Not Detected 5.2 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 2.6 Not Detected 0.50 Not Detected 3.0 Not Detected 2.0 Not Detected 15 Not Detected 2.0 Not Detected 21 Not Detected Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 10 of 16
118 Client Sample ID: CCV Lab ID#: A File Name: p Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/5/17 12:06 PM Page 11 of 16
119 Client Sample ID: CCV Lab ID#: A File Name: p Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/5/17 12:06 PM Page 12 of 16
120 Client Sample ID: LCS Lab ID#: A File Name: p Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/5/17 12:32 PM Page 13 of 16
121 Client Sample ID: LCS Lab ID#: A File Name: p Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/5/17 12:32 PM Page 14 of 16
122 Client Sample ID: LCSD Lab ID#: AA File Name: p Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/5/17 12:59 PM Page 15 of 16
123 Client Sample ID: LCSD Lab ID#: AA File Name: p Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/5/17 12:59 PM Page 16 of 16
124
125 1/17/2017 Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan MN Project Name: Shoreham Yards Project #: Workorder #: Dear Mr. Brian Deering The following report includes the data for the above referenced project for sample(s) received on 1/5/2017 at Air Toxics Ltd. The data and associated QC analyzed by TO-15 are compliant with the project requirements or laboratory criteria with the exception of the deviations noted in the attached case narrative. Thank you for choosing Eurofins Air Toxics Inc. for your air analysis needs. Eurofins Air Toxics Inc. is committed to providing accurate data of the highest quality. Please feel free to contact the Project Manager: Ausha Scott at if you have any questions regarding the data in this report. Regards, Ausha Scott Project Manager Page 1 of 16
126 WORK ORDER #: Work Order Summary CLIENT: PHONE: FAX: Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan, MN DATE RECEIVED: 01/05/2017 DATE COMPLETED: 01/17/2017 BILL TO: PROJECT # CONTACT: Accounts Payable Groundwater & Environmental Services, Inc. (GES) 1350 Blair Drive, Suite A Odenton, MD P.O. # /22100/220 Shoreham Yards Ausha Scott RECEIPT FRACTION # NAME TEST VAC./PRES. FINAL PRESSURE 01A Till TO "Hg 5.1 psi 02A Alluvium TO "Hg 4.5 psi 03A Lab Blank TO-15 NA NA 04A CCV TO-15 NA NA 05A LCS TO-15 NA NA 05AA LCSD TO-15 NA NA CERTIFIED BY: DATE: 01/17/17 Technical Director Certification numbers: AZ Licensure AZ0775, NJ NELAP - CA016, NY NELAP , TX NELAP - T , UT NELAP CA , VA NELAP , WA NELAP - C935 Name of Accreditation Body: NELAP/ORELAP (Oregon Environmental Laboratory Accreditation Program) Accreditation number: CA300005, Effective date: 10/18/2016, Expiration date: 10/17/2017. Eurofins Air Toxics Inc.. certifies that the test results contained in this report meet all requirements of the NELAC standards This report shall not be reproduced, except in full, without the written approval of Eurofins Air Toxics, Inc. 180 BLUE RAVINE ROAD, SUITE B FOLSOM, CA (916) (800) FAX (916) Page 2 of 16
127 LABORATORY NARRATIVE EPA TO-15 Groundwater & Environmental Services, Inc. (GES) Workorder# Two 6 Liter Summa Canister samples were received on January 05, The laboratory performed analysis via EPA TO-15 using GC/MS in the full scan mode. This workorder was independently validated prior to submittal using 'USEPA National Functional Guidelines' as generally applied to the analysis of volatile organic compounds in air. A rules-based, logic driven, independent validation engine was employed to assess completeness, evaluate pass/fail of relevant project quality control requirements and verification of all quantified amounts. Receiving Notes There were no receiving discrepancies. Analytical Notes There were no analytical discrepancies. Definition of Data Qualifying Flags Eight qualifiers may have been used on the data analysis sheets and indicates as follows: B - present in laboratory blank greater than reporting limit (background subtraction not performed). J - Estimated value. E - Exceeds instrument calibration range. S - Saturated peak. Q - Exceeds quality control limits. U - analyzed for but not detected above the reporting limit, LOD, or MDL value. See data page for project specific U-flag definition. UJ- Non-detected compound associated with low bias in the CCV N - The identification is based on presumptive evidence. File extensions may have been used on the data analysis sheets and indicates as follows: a-file was requantified b-file was quantified by a second column and detector r1-file was requantified for the purpose of reissue Page 3 of 16
128 Summary of Detected s Client Sample ID: Till Lab ID#: A 1,1-Dichloroethane cis-1,2-dichloroethene 1,1,1-Trichloroethane Trichloroethene 1,1,2-Trichloroethane Tetrachloroethene Client Sample ID: Alluvium Lab ID#: A Freon 12 cis-1,2-dichloroethene 1,1,1-Trichloroethane Trichloroethene 1,1,2-Trichloroethane Tetrachloroethene Page 4 of 16
129 File Name: Dil. Factor: 1.64 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Till Lab ID#: A Date of Collection: 1/3/17 1:00:00 PM Date of Analysis: 1/9/17 11:14 PM 0.82 Not Detected 4.0 Not Detected 0.82 Not Detected 5.7 Not Detected 8.2 Not Detected 17 Not Detected 0.82 Not Detected 2.1 Not Detected 0.82 Not Detected 1.8 Not Detected 8.2 Not Detected 32 Not Detected 3.3 Not Detected 8.6 Not Detected 0.82 Not Detected 4.6 Not Detected 3.3 Not Detected 6.2 Not Detected 0.82 Not Detected 6.3 Not Detected 0.82 Not Detected 3.2 Not Detected 8.2 Not Detected 19 Not Detected 3.3 Not Detected 8.1 Not Detected 3.3 Not Detected 10 Not Detected 3.3 Not Detected 10 Not Detected 8.2 Not Detected 28 Not Detected 3.3 Not Detected 12 Not Detected 0.82 Not Detected 3.2 Not Detected 0.82 Not Detected 2.9 Not Detected Not Detected 9.7 Not Detected Not Detected 2.4 Not Detected 0.82 Not Detected 4.0 Not Detected Not Detected 2.8 Not Detected 0.82 Not Detected 5.2 Not Detected 0.82 Not Detected 3.8 Not Detected 0.82 Not Detected 2.6 Not Detected 0.82 Not Detected 3.3 Not Detected 0.82 Not Detected 3.4 Not Detected Not Detected 3.8 Not Detected 3.3 Not Detected 12 Not Detected 0.82 Not Detected 5.5 Not Detected 0.82 Not Detected 3.7 Not Detected 0.82 Not Detected 3.4 Not Detected 0.82 Not Detected 3.1 Not Detected 0.82 Not Detected 3.7 Not Detected Not Detected 13 Not Detected Page 5 of 16
130 File Name: Dil. Factor: 1.64 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Till Lab ID#: A Date of Collection: 1/3/17 1:00:00 PM Date of Analysis: 1/9/17 11:14 PM 0.82 Not Detected 7.0 Not Detected 0.82 Not Detected 6.3 Not Detected 0.82 Not Detected 3.8 Not Detected 0.82 Not Detected 3.6 Not Detected 0.82 Not Detected 3.6 Not Detected 0.82 Not Detected 3.6 Not Detected 0.82 Not Detected 3.5 Not Detected 0.82 Not Detected 8.5 Not Detected 0.82 Not Detected 4.0 Not Detected 0.82 Not Detected 5.6 Not Detected 0.82 Not Detected 4.0 Not Detected 0.82 Not Detected 4.0 Not Detected 0.82 Not Detected 4.0 Not Detected 0.82 Not Detected 4.0 Not Detected 0.82 Not Detected 4.9 Not Detected 0.82 Not Detected 4.9 Not Detected 0.82 Not Detected 4.2 Not Detected 0.82 Not Detected 4.9 Not Detected 3.3 Not Detected 24 Not Detected 3.3 Not Detected 35 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 6 of 16
131 File Name: Dil. Factor: 1.61 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Alluvium Lab ID#: A Date of Collection: 1/3/17 1:12:00 PM Date of Analysis: 1/9/17 11:40 PM Not Detected 5.6 Not Detected 8.0 Not Detected 17 Not Detected 0.80 Not Detected 2.0 Not Detected 0.80 Not Detected 1.8 Not Detected 8.0 Not Detected 31 Not Detected 3.2 Not Detected 8.5 Not Detected 0.80 Not Detected 4.5 Not Detected 3.2 Not Detected 6.1 Not Detected 0.80 Not Detected 6.2 Not Detected 0.80 Not Detected 3.2 Not Detected 8.0 Not Detected 19 Not Detected 3.2 Not Detected 7.9 Not Detected 3.2 Not Detected 10 Not Detected 3.2 Not Detected 10 Not Detected 8.0 Not Detected 28 Not Detected 3.2 Not Detected 12 Not Detected 0.80 Not Detected 3.2 Not Detected 0.80 Not Detected 2.8 Not Detected 0.80 Not Detected 3.2 Not Detected 3.2 Not Detected 9.5 Not Detected Not Detected 2.4 Not Detected 0.80 Not Detected 3.9 Not Detected Not Detected 2.8 Not Detected 0.80 Not Detected 5.1 Not Detected 0.80 Not Detected 3.8 Not Detected 0.80 Not Detected 2.6 Not Detected 0.80 Not Detected 3.2 Not Detected 0.80 Not Detected 3.3 Not Detected Not Detected 3.7 Not Detected 3.2 Not Detected 12 Not Detected 0.80 Not Detected 5.4 Not Detected 0.80 Not Detected 3.6 Not Detected 0.80 Not Detected 3.3 Not Detected 0.80 Not Detected 3.0 Not Detected 0.80 Not Detected 3.6 Not Detected Not Detected 13 Not Detected Page 7 of 16
132 File Name: Dil. Factor: 1.61 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Alluvium Lab ID#: A Date of Collection: 1/3/17 1:12:00 PM Date of Analysis: 1/9/17 11:40 PM 0.80 Not Detected 6.8 Not Detected 0.80 Not Detected 6.2 Not Detected 0.80 Not Detected 3.7 Not Detected 0.80 Not Detected 3.5 Not Detected 0.80 Not Detected 3.5 Not Detected 0.80 Not Detected 3.5 Not Detected 0.80 Not Detected 3.4 Not Detected 0.80 Not Detected 8.3 Not Detected 0.80 Not Detected 4.0 Not Detected 0.80 Not Detected 5.5 Not Detected 0.80 Not Detected 4.0 Not Detected 0.80 Not Detected 4.0 Not Detected 0.80 Not Detected 4.0 Not Detected 0.80 Not Detected 4.0 Not Detected 0.80 Not Detected 4.8 Not Detected 0.80 Not Detected 4.8 Not Detected 0.80 Not Detected 4.2 Not Detected 0.80 Not Detected 4.8 Not Detected 3.2 Not Detected 24 Not Detected 3.2 Not Detected 34 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 8 of 16
133 File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 1/9/17 03:43 PM 0.50 Not Detected 2.5 Not Detected 0.50 Not Detected 3.5 Not Detected 5.0 Not Detected 10 Not Detected 0.50 Not Detected 1.3 Not Detected 0.50 Not Detected 1.1 Not Detected 5.0 Not Detected 19 Not Detected 2.0 Not Detected 5.3 Not Detected 0.50 Not Detected 2.8 Not Detected 2.0 Not Detected 3.8 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.0 Not Detected 5.0 Not Detected 12 Not Detected 2.0 Not Detected 4.9 Not Detected 2.0 Not Detected 6.2 Not Detected 2.0 Not Detected 6.3 Not Detected 5.0 Not Detected 17 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.8 Not Detected 0.50 Not Detected 2.0 Not Detected 2.0 Not Detected 5.9 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.5 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 1.7 Not Detected 0.50 Not Detected 3.1 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 1.6 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 2.3 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.9 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 3.4 Not Detected 2.0 Not Detected 8.2 Not Detected Page 9 of 16
134 File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 1/9/17 03:43 PM 0.50 Not Detected 4.2 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.1 Not Detected 0.50 Not Detected 5.2 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 2.6 Not Detected 0.50 Not Detected 3.0 Not Detected 2.0 Not Detected 15 Not Detected 2.0 Not Detected 21 Not Detected Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 10 of 16
135 Client Sample ID: CCV Lab ID#: A File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/9/17 12:22 PM Page 11 of 16
136 Client Sample ID: CCV Lab ID#: A File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/9/17 12:22 PM Page 12 of 16
137 Client Sample ID: LCS Lab ID#: A File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/9/17 12:48 PM Page 13 of 16
138 Client Sample ID: LCS Lab ID#: A File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/9/17 12:48 PM Page 14 of 16
139 Client Sample ID: LCSD Lab ID#: AA File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/9/17 01:15 PM Page 15 of 16
140 Client Sample ID: LCSD Lab ID#: AA File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/9/17 01:15 PM Page 16 of 16
141
142 1/16/2017 Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan MN Project Name: Shoreham Yards Project #: Workorder #: Dear Mr. Brian Deering The following report includes the data for the above referenced project for sample(s) received on 1/9/2017 at Air Toxics Ltd. The data and associated QC analyzed by TO-15 are compliant with the project requirements or laboratory criteria with the exception of the deviations noted in the attached case narrative. Thank you for choosing Eurofins Air Toxics Inc. for your air analysis needs. Eurofins Air Toxics Inc. is committed to providing accurate data of the highest quality. Please feel free to contact the Project Manager: Ausha Scott at if you have any questions regarding the data in this report. Regards, Ausha Scott Project Manager Page 1 of 16
143 WORK ORDER #: Work Order Summary CLIENT: PHONE: FAX: Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan, MN DATE RECEIVED: 01/09/2017 DATE COMPLETED: 01/16/2017 BILL TO: PROJECT # CONTACT: Accounts Payable Groundwater & Environmental Services, Inc. (GES) 1350 Blair Drive, Suite A Odenton, MD P.O. # Shoreham Yards Ausha Scott RECEIPT FRACTION # NAME TEST VAC./PRES. FINAL PRESSURE 01A Till TO "Hg 5 psi 02A Alluvium TO "Hg 5.1 psi 03A Lab Blank TO-15 NA NA 04A CCV TO-15 NA NA 05A LCS TO-15 NA NA 05AA LCSD TO-15 NA NA CERTIFIED BY: DATE: 01/16/17 Technical Director Certification numbers: AZ Licensure AZ0775, NJ NELAP - CA016, NY NELAP , TX NELAP - T , UT NELAP CA , VA NELAP , WA NELAP - C935 Name of Accreditation Body: NELAP/ORELAP (Oregon Environmental Laboratory Accreditation Program) Accreditation number: CA300005, Effective date: 10/18/2016, Expiration date: 10/17/2017. Eurofins Air Toxics Inc.. certifies that the test results contained in this report meet all requirements of the NELAC standards This report shall not be reproduced, except in full, without the written approval of Eurofins Air Toxics, Inc. 180 BLUE RAVINE ROAD, SUITE B FOLSOM, CA (916) (800) FAX (916) Page 2 of 16
144 LABORATORY NARRATIVE EPA TO-15 Groundwater & Environmental Services, Inc. (GES) Workorder# Two 6 Liter Summa Canister samples were received on January 09, The laboratory performed analysis via EPA TO-15 using GC/MS in the full scan mode. This workorder was independently validated prior to submittal using 'USEPA National Functional Guidelines' as generally applied to the analysis of volatile organic compounds in air. A rules-based, logic driven, independent validation engine was employed to assess completeness, evaluate pass/fail of relevant project quality control requirements and verification of all quantified amounts. Receiving Notes There were no receiving discrepancies. Analytical Notes All Quality Control Limit exceedances and affected sample results are noted by flags. Each flag is defined at the bottom of this Case Narrative and on each Sample Result Summary page. Definition of Data Qualifying Flags Eight qualifiers may have been used on the data analysis sheets and indicates as follows: B - present in laboratory blank greater than reporting limit (background subtraction not performed). J - Estimated value. E - Exceeds instrument calibration range. S - Saturated peak. Q - Exceeds quality control limits. U - analyzed for but not detected above the reporting limit, LOD, or MDL value. See data page for project specific U-flag definition. UJ- Non-detected compound associated with low bias in the CCV N - The identification is based on presumptive evidence. File extensions may have been used on the data analysis sheets and indicates as follows: a-file was requantified b-file was quantified by a second column and detector r1-file was requantified for the purpose of reissue Page 3 of 16
145 Summary of Detected s Client Sample ID: Till Lab ID#: A cis-1,2-dichloroethene 1,1,1-Trichloroethane Trichloroethene 1,1,2-Trichloroethane Tetrachloroethene J J Client Sample ID: Alluvium Lab ID#: A Trichloroethene Tetrachloroethene Page 4 of 16
146 File Name: Dil. Factor: 1.65 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Till Lab ID#: A Date of Collection: 1/4/17 1:00:00 PM Date of Analysis: 1/11/17 11:55 PM 0.82 Not Detected 4.1 Not Detected 0.82 Not Detected 5.8 Not Detected 8.2 Not Detected 17 Not Detected 0.82 Not Detected 2.1 Not Detected 0.82 Not Detected 1.8 Not Detected 8.2 Not Detected 32 Not Detected 3.3 Not Detected 8.7 Not Detected 0.82 Not Detected 4.6 Not Detected 3.3 Not Detected 6.2 Not Detected 0.82 Not Detected 6.3 Not Detected 0.82 Not Detected 3.3 Not Detected 8.2 Not Detected 20 Not Detected 3.3 Not Detected 8.1 Not Detected 3.3 Not Detected 10 Not Detected 3.3 Not Detected 10 Not Detected 8.2 Not Detected 29 Not Detected 3.3 Not Detected 12 Not Detected 0.82 Not Detected 3.3 Not Detected 0.82 Not Detected 2.9 Not Detected 0.82 Not Detected 3.3 Not Detected 3.3 Not Detected 9.7 Not Detected J J 0.82 Not Detected 2.4 Not Detected 0.82 Not Detected 4.0 Not Detected Not Detected 2.8 Not Detected 0.82 Not Detected 5.2 Not Detected 0.82 Not Detected 3.8 Not Detected 0.82 Not Detected 2.6 Not Detected 0.82 Not Detected 3.3 Not Detected 0.82 Not Detected 3.4 Not Detected Not Detected 3.8 Not Detected 3.3 Not Detected 12 Not Detected 0.82 Not Detected 5.5 Not Detected 0.82 Not Detected 3.7 Not Detected 0.82 Not Detected 3.4 Not Detected 0.82 Not Detected 3.1 Not Detected 0.82 Not Detected 3.7 Not Detected Not Detected 14 Not Detected Page 5 of 16
147 File Name: Dil. Factor: 1.65 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Till Lab ID#: A Date of Collection: 1/4/17 1:00:00 PM Date of Analysis: 1/11/17 11:55 PM 0.82 Not Detected 7.0 Not Detected 0.82 Not Detected 6.3 Not Detected 0.82 Not Detected 3.8 Not Detected 0.82 Not Detected 3.6 Not Detected 0.82 Not Detected 3.6 Not Detected 0.82 Not Detected 3.6 Not Detected 0.82 Not Detected 3.5 Not Detected 0.82 Not Detected 8.5 Not Detected 0.82 Not Detected 4.0 Not Detected 0.82 Not Detected 5.7 Not Detected 0.82 Not Detected 4.0 Not Detected 0.82 Not Detected 4.0 Not Detected 0.82 Not Detected 4.0 Not Detected 0.82 Not Detected 4.0 Not Detected 0.82 Not Detected 5.0 Not Detected 0.82 Not Detected 5.0 Not Detected 0.82 Not Detected 4.3 Not Detected 0.82 Not Detected 5.0 Not Detected 3.3 Not Detected 24 Not Detected 3.3 Not Detected 35 Not Detected J = Estimated value. Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 6 of 16
148 File Name: Dil. Factor: 1.60 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Alluvium Lab ID#: A Date of Collection: 1/4/17 1:20:00 PM Date of Analysis: 1/12/17 12:21 AM 0.80 Not Detected 4.0 Not Detected 0.80 Not Detected 5.6 Not Detected 8.0 Not Detected 16 Not Detected 0.80 Not Detected 2.0 Not Detected 0.80 Not Detected 1.8 Not Detected 8.0 Not Detected 31 Not Detected 3.2 Not Detected 8.4 Not Detected 0.80 Not Detected 4.5 Not Detected 3.2 Not Detected 6.0 Not Detected 0.80 Not Detected 6.1 Not Detected 0.80 Not Detected 3.2 Not Detected 8.0 Not Detected 19 Not Detected 3.2 Not Detected 7.9 Not Detected 3.2 Not Detected 10 Not Detected 3.2 Not Detected 10 Not Detected 8.0 Not Detected 28 Not Detected 3.2 Not Detected 12 Not Detected 0.80 Not Detected 3.2 Not Detected 0.80 Not Detected 2.8 Not Detected 0.80 Not Detected 3.2 Not Detected 3.2 Not Detected 9.4 Not Detected 0.80 Not Detected 3.2 Not Detected 0.80 Not Detected 2.4 Not Detected 0.80 Not Detected 3.9 Not Detected 0.80 Not Detected 4.4 Not Detected 0.80 Not Detected 2.8 Not Detected 0.80 Not Detected 5.0 Not Detected 0.80 Not Detected 3.7 Not Detected 0.80 Not Detected 2.6 Not Detected 0.80 Not Detected 3.2 Not Detected 0.80 Not Detected 3.3 Not Detected Not Detected 3.7 Not Detected 3.2 Not Detected 12 Not Detected 0.80 Not Detected 5.4 Not Detected 0.80 Not Detected 3.6 Not Detected 0.80 Not Detected 3.3 Not Detected 0.80 Not Detected 3.0 Not Detected 0.80 Not Detected 3.6 Not Detected 0.80 Not Detected 4.4 Not Detected Not Detected 13 Not Detected Page 7 of 16
149 File Name: Dil. Factor: 1.60 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Alluvium Lab ID#: A Date of Collection: 1/4/17 1:20:00 PM Date of Analysis: 1/12/17 12:21 AM 0.80 Not Detected 6.8 Not Detected 0.80 Not Detected 6.1 Not Detected 0.80 Not Detected 3.7 Not Detected 0.80 Not Detected 3.5 Not Detected 0.80 Not Detected 3.5 Not Detected 0.80 Not Detected 3.5 Not Detected 0.80 Not Detected 3.4 Not Detected 0.80 Not Detected 8.3 Not Detected 0.80 Not Detected 3.9 Not Detected 0.80 Not Detected 5.5 Not Detected 0.80 Not Detected 3.9 Not Detected 0.80 Not Detected 3.9 Not Detected 0.80 Not Detected 3.9 Not Detected 0.80 Not Detected 3.9 Not Detected 0.80 Not Detected 4.8 Not Detected 0.80 Not Detected 4.8 Not Detected 0.80 Not Detected 4.1 Not Detected 0.80 Not Detected 4.8 Not Detected 3.2 Not Detected 24 Not Detected 3.2 Not Detected 34 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 8 of 16
150 File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 1/11/17 02:11 PM 0.50 Not Detected 2.5 Not Detected 0.50 Not Detected 3.5 Not Detected 5.0 Not Detected 10 Not Detected 0.50 Not Detected 1.3 Not Detected 0.50 Not Detected 1.1 Not Detected 5.0 Not Detected 19 Not Detected 2.0 Not Detected 5.3 Not Detected 0.50 Not Detected 2.8 Not Detected 2.0 Not Detected 3.8 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.0 Not Detected 5.0 Not Detected 12 Not Detected 2.0 Not Detected 4.9 Not Detected 2.0 Not Detected 6.2 Not Detected 2.0 Not Detected 6.3 Not Detected 5.0 Not Detected 17 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.8 Not Detected 0.50 Not Detected 2.0 Not Detected 2.0 Not Detected 5.9 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.5 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 1.7 Not Detected 0.50 Not Detected 3.1 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 1.6 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 2.3 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.9 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 3.4 Not Detected 2.0 Not Detected 8.2 Not Detected Page 9 of 16
151 File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 1/11/17 02:11 PM 0.50 Not Detected 4.2 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.1 Not Detected 0.50 Not Detected 5.2 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 2.6 Not Detected 0.50 Not Detected 3.0 Not Detected 2.0 Not Detected 15 Not Detected 2.0 Not Detected 21 Not Detected Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 10 of 16
152 Client Sample ID: CCV Lab ID#: A File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/11/17 11:53 AM Page 11 of 16
153 Client Sample ID: CCV Lab ID#: A File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/11/17 11:53 AM Page 12 of 16
154 Client Sample ID: LCS Lab ID#: A File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/11/17 10:06 AM Q Page 13 of 16
155 Client Sample ID: LCS Lab ID#: A File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Q = Exceeds Quality Control limits. Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/11/17 10:06 AM Page 14 of 16
156 Client Sample ID: LCSD Lab ID#: AA File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/11/17 10:32 AM Q Page 15 of 16
157 Client Sample ID: LCSD Lab ID#: AA File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Q = Exceeds Quality Control limits. Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/11/17 10:32 AM Page 16 of 16
158
159 1/23/2017 Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan MN Project Name: Shoreham Yards Project #: Workorder #: R1 Dear Mr. Brian Deering The following report includes the data for the above referenced project for sample(s) received on 1/20/2017 at Air Toxics Ltd. The data and associated QC analyzed by TO-15 are compliant with the project requirements or laboratory criteria with the exception of the deviations noted in the attached case narrative. Thank you for choosing Eurofins Air Toxics Inc. for your air analysis needs. Eurofins Air Toxics Inc. is committed to providing accurate data of the highest quality. Please feel free to contact the Project Manager: Ausha Scott at if you have any questions regarding the data in this report. Regards, Ausha Scott Project Manager Page 1 of 16
160 WORK ORDER #: R1 Work Order Summary CLIENT: PHONE: FAX: Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan, MN DATE RECEIVED: 01/20/2017 DATE COMPLETED: 01/18/2017 DATE REISSUED: 01/23/2017 BILL TO: PROJECT # CONTACT: Accounts Payable Groundwater & Environmental Services, Inc. (GES) 1350 Blair Drive, Suite A Odenton, MD P.O. # /22100/220 Shoreham Yards Ausha Scott RECEIPT FRACTION # NAME TEST VAC./PRES. FINAL PRESSURE 01A Till TO "Hg 5.1 psi 02A Alluvium TO "Hg 4.9 psi 03A Lab Blank TO-15 NA NA 04A CCV TO-15 NA NA 05A LCS TO-15 NA NA 05AA LCSD TO-15 NA NA CERTIFIED BY: DATE: 01/23/17 Technical Director Certification numbers: AZ Licensure AZ0775, NJ NELAP - CA016, NY NELAP , TX NELAP - T , UT NELAP CA , VA NELAP , WA NELAP - C935 Name of Accreditation Body: NELAP/ORELAP (Oregon Environmental Laboratory Accreditation Program) Accreditation number: CA300005, Effective date: 10/18/2016, Expiration date: 10/17/2017. Eurofins Air Toxics Inc.. certifies that the test results contained in this report meet all requirements of the NELAC standards This report shall not be reproduced, except in full, without the written approval of Eurofins Air Toxics, Inc. 180 BLUE RAVINE ROAD, SUITE B FOLSOM, CA (916) (800) FAX (916) Page 2 of 16
161 LABORATORY NARRATIVE EPA TO-15 Groundwater & Environmental Services, Inc. (GES) Workorder# R1 Two 6 Liter Summa Canister samples were received on January 10, The laboratory performed analysis via EPA TO-15 using GC/MS in the full scan mode. This workorder was independently validated prior to submittal using 'USEPA National Functional Guidelines' as generally applied to the analysis of volatile organic compounds in air. A rules-based, logic driven, independent validation engine was employed to assess completeness, evaluate pass/fail of relevant project quality control requirements and verification of all quantified amounts. Receiving Notes There were no receiving discrepancies. Analytical Notes There were no analytical discrepancies. The workorder was reissued on January 23, 2017 to correct the surrogate recoveries in samples Till and Alluvium due to laboratory error. Definition of Data Qualifying Flags Eight qualifiers may have been used on the data analysis sheets and indicates as follows: B - present in laboratory blank greater than reporting limit (background subtraction not performed). J - Estimated value. E - Exceeds instrument calibration range. S - Saturated peak. Q - Exceeds quality control limits. U - analyzed for but not detected above the reporting limit, LOD, or MDL value. See data page for project specific U-flag definition. UJ- Non-detected compound associated with low bias in the CCV N - The identification is based on presumptive evidence. File extensions may have been used on the data analysis sheets and indicates as follows: a-file was requantified b-file was quantified by a second column and detector r1-file was requantified for the purpose of reissue Page 3 of 16
162 Summary of Detected s Client Sample ID: Till Lab ID#: R1-01A Ethanol Acetone cis-1,2-dichloroethene 1,1,1-Trichloroethane Trichloroethene Toluene 1,1,2-Trichloroethane Tetrachloroethene Client Sample ID: Alluvium Lab ID#: R1-02A 2-Butanone (Methyl Ethyl Ketone) 1,1,1-Trichloroethane Trichloroethene Tetrachloroethene Page 4 of 16
163 File Name: r1 Dil. Factor: 1.73 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Till Lab ID#: R1-01A Date of Collection: 1/6/17 1:00:00 PM Date of Analysis: 1/12/17 07:29 PM 0.86 Not Detected 4.3 Not Detected 0.86 Not Detected 6.0 Not Detected 8.6 Not Detected 18 Not Detected 0.86 Not Detected 2.2 Not Detected 0.86 Not Detected 1.9 Not Detected 8.6 Not Detected 34 Not Detected 3.5 Not Detected 9.1 Not Detected 0.86 Not Detected 4.9 Not Detected Not Detected 6.6 Not Detected 0.86 Not Detected 3.4 Not Detected Not Detected 8.5 Not Detected 3.5 Not Detected 11 Not Detected 3.5 Not Detected 11 Not Detected 8.6 Not Detected 30 Not Detected 3.5 Not Detected 12 Not Detected 0.86 Not Detected 3.4 Not Detected 0.86 Not Detected 3.0 Not Detected 0.86 Not Detected 3.5 Not Detected 3.5 Not Detected 10 Not Detected Not Detected 2.6 Not Detected 0.86 Not Detected 4.2 Not Detected Not Detected 3.0 Not Detected 0.86 Not Detected 5.4 Not Detected 0.86 Not Detected 4.0 Not Detected 0.86 Not Detected 2.8 Not Detected 0.86 Not Detected 3.5 Not Detected 0.86 Not Detected 3.5 Not Detected Not Detected 4.0 Not Detected 3.5 Not Detected 12 Not Detected 0.86 Not Detected 5.8 Not Detected 0.86 Not Detected 3.9 Not Detected 0.86 Not Detected 3.5 Not Detected Not Detected 3.9 Not Detected Not Detected 14 Not Detected Page 5 of 16
164 File Name: r1 Dil. Factor: 1.73 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Till Lab ID#: R1-01A Date of Collection: 1/6/17 1:00:00 PM Date of Analysis: 1/12/17 07:29 PM 0.86 Not Detected 7.4 Not Detected 0.86 Not Detected 6.6 Not Detected 0.86 Not Detected 4.0 Not Detected 0.86 Not Detected 3.8 Not Detected 0.86 Not Detected 3.8 Not Detected 0.86 Not Detected 3.8 Not Detected 0.86 Not Detected 3.7 Not Detected 0.86 Not Detected 8.9 Not Detected 0.86 Not Detected 4.2 Not Detected 0.86 Not Detected 5.9 Not Detected 0.86 Not Detected 4.2 Not Detected 0.86 Not Detected 4.2 Not Detected 0.86 Not Detected 4.2 Not Detected 0.86 Not Detected 4.2 Not Detected 0.86 Not Detected 5.2 Not Detected 0.86 Not Detected 5.2 Not Detected 0.86 Not Detected 4.5 Not Detected 0.86 Not Detected 5.2 Not Detected 3.5 Not Detected 26 Not Detected 3.5 Not Detected 37 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 6 of 16
165 File Name: r1 Dil. Factor: 1.58 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Alluvium Lab ID#: R1-02A Date of Collection: 1/6/17 1:15:00 PM Date of Analysis: 1/12/17 07:00 PM 0.79 Not Detected 3.9 Not Detected 0.79 Not Detected 5.5 Not Detected 7.9 Not Detected 16 Not Detected 0.79 Not Detected 2.0 Not Detected 0.79 Not Detected 1.7 Not Detected 7.9 Not Detected 31 Not Detected 3.2 Not Detected 8.3 Not Detected 0.79 Not Detected 4.4 Not Detected 3.2 Not Detected 6.0 Not Detected 0.79 Not Detected 6.0 Not Detected 0.79 Not Detected 3.1 Not Detected 7.9 Not Detected 19 Not Detected 3.2 Not Detected 7.8 Not Detected 3.2 Not Detected 9.8 Not Detected 3.2 Not Detected 9.9 Not Detected 7.9 Not Detected 27 Not Detected 3.2 Not Detected 11 Not Detected 0.79 Not Detected 3.1 Not Detected 0.79 Not Detected 2.8 Not Detected 0.79 Not Detected 3.2 Not Detected Not Detected 3.1 Not Detected 0.79 Not Detected 2.3 Not Detected 0.79 Not Detected 3.8 Not Detected Not Detected 2.7 Not Detected 0.79 Not Detected 5.0 Not Detected 0.79 Not Detected 3.7 Not Detected 0.79 Not Detected 2.5 Not Detected 0.79 Not Detected 3.2 Not Detected 0.79 Not Detected 3.2 Not Detected Not Detected 3.6 Not Detected 3.2 Not Detected 11 Not Detected 0.79 Not Detected 5.3 Not Detected 0.79 Not Detected 3.6 Not Detected 0.79 Not Detected 3.2 Not Detected 0.79 Not Detected 3.0 Not Detected 0.79 Not Detected 3.6 Not Detected 0.79 Not Detected 4.3 Not Detected Not Detected 13 Not Detected Page 7 of 16
166 File Name: r1 Dil. Factor: 1.58 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Alluvium Lab ID#: R1-02A Date of Collection: 1/6/17 1:15:00 PM Date of Analysis: 1/12/17 07:00 PM 0.79 Not Detected 6.7 Not Detected 0.79 Not Detected 6.1 Not Detected 0.79 Not Detected 3.6 Not Detected 0.79 Not Detected 3.4 Not Detected 0.79 Not Detected 3.4 Not Detected 0.79 Not Detected 3.4 Not Detected 0.79 Not Detected 3.4 Not Detected 0.79 Not Detected 8.2 Not Detected 0.79 Not Detected 3.9 Not Detected 0.79 Not Detected 5.4 Not Detected 0.79 Not Detected 3.9 Not Detected 0.79 Not Detected 3.9 Not Detected 0.79 Not Detected 3.9 Not Detected 0.79 Not Detected 3.9 Not Detected 0.79 Not Detected 4.8 Not Detected 0.79 Not Detected 4.8 Not Detected 0.79 Not Detected 4.1 Not Detected 0.79 Not Detected 4.7 Not Detected 3.2 Not Detected 23 Not Detected 3.2 Not Detected 34 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 8 of 16
167 File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Lab Blank Lab ID#: R1-03A Date of Collection: NA Date of Analysis: 1/12/17 12:25 PM 0.50 Not Detected 2.5 Not Detected 0.50 Not Detected 3.5 Not Detected 5.0 Not Detected 10 Not Detected 0.50 Not Detected 1.3 Not Detected 0.50 Not Detected 1.1 Not Detected 5.0 Not Detected 19 Not Detected 2.0 Not Detected 5.3 Not Detected 0.50 Not Detected 2.8 Not Detected 2.0 Not Detected 3.8 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.0 Not Detected 5.0 Not Detected 12 Not Detected 2.0 Not Detected 4.9 Not Detected 2.0 Not Detected 6.2 Not Detected 2.0 Not Detected 6.3 Not Detected 5.0 Not Detected 17 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.8 Not Detected 0.50 Not Detected 2.0 Not Detected 2.0 Not Detected 5.9 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.5 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 1.7 Not Detected 0.50 Not Detected 3.1 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 1.6 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 2.3 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.9 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 3.4 Not Detected 2.0 Not Detected 8.2 Not Detected Page 9 of 16
168 File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Lab Blank Lab ID#: R1-03A Date of Collection: NA Date of Analysis: 1/12/17 12:25 PM 0.50 Not Detected 4.2 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.1 Not Detected 0.50 Not Detected 5.2 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 2.6 Not Detected 0.50 Not Detected 3.0 Not Detected 2.0 Not Detected 15 Not Detected 2.0 Not Detected 21 Not Detected Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 10 of 16
169 Client Sample ID: CCV Lab ID#: R1-04A File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/12/17 10:53 AM Page 11 of 16
170 Client Sample ID: CCV Lab ID#: R1-04A File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/12/17 10:53 AM Page 12 of 16
171 Client Sample ID: LCS Lab ID#: R1-05A File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/12/17 11:20 AM Page 13 of 16
172 Client Sample ID: LCS Lab ID#: R1-05A File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/12/17 11:20 AM Page 14 of 16
173 Client Sample ID: LCSD Lab ID#: R1-05AA File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/12/17 11:47 AM Page 15 of 16
174 Client Sample ID: LCSD Lab ID#: R1-05AA File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/12/17 11:47 AM Page 16 of 16
175
176 1/30/2017 Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan MN Project Name: Shoreham Yards Project #: Workorder #: Dear Mr. Brian Deering The following report includes the data for the above referenced project for sample(s) received on 1/19/2017 at Air Toxics Ltd. The data and associated QC analyzed by TO-15 are compliant with the project requirements or laboratory criteria with the exception of the deviations noted in the attached case narrative. Thank you for choosing Eurofins Air Toxics Inc. for your air analysis needs. Eurofins Air Toxics Inc. is committed to providing accurate data of the highest quality. Please feel free to contact the Project Manager: Ausha Scott at if you have any questions regarding the data in this report. Regards, Ausha Scott Project Manager Page 1 of 16
177 WORK ORDER #: Work Order Summary CLIENT: PHONE: FAX: Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan, MN DATE RECEIVED: 01/19/2017 DATE COMPLETED: 01/30/2017 BILL TO: PROJECT # CONTACT: Accounts Payable Groundwater & Environmental Services, Inc. (GES) 1350 Blair Drive, Suite A Odenton, MD P.O. # Shoreham Yards Ausha Scott RECEIPT FRACTION # NAME TEST VAC./PRES. FINAL PRESSURE 01A Till TO "Hg 5.2 psi 02A Alluvium TO "Hg 5.2 psi 03A Lab Blank TO-15 NA NA 04A CCV TO-15 NA NA 05A LCS TO-15 NA NA 05AA LCSD TO-15 NA NA CERTIFIED BY: DATE: 01/30/17 Technical Director Certification numbers: AZ Licensure AZ0775, NJ NELAP - CA016, NY NELAP , TX NELAP - T , UT NELAP CA , VA NELAP , WA NELAP - C935 Name of Accreditation Body: NELAP/ORELAP (Oregon Environmental Laboratory Accreditation Program) Accreditation number: CA300005, Effective date: 10/18/2016, Expiration date: 10/17/2017. Eurofins Air Toxics Inc.. certifies that the test results contained in this report meet all requirements of the NELAC standards This report shall not be reproduced, except in full, without the written approval of Eurofins Air Toxics, Inc. 180 BLUE RAVINE ROAD, SUITE B FOLSOM, CA (916) (800) FAX (916) Page 2 of 16
178 LABORATORY NARRATIVE EPA TO-15 Groundwater & Environmental Services, Inc. (GES) Workorder# Two 6 Liter Summa Canister samples were received on January 19, The laboratory performed analysis via EPA TO-15 using GC/MS in the full scan mode. This workorder was independently validated prior to submittal using 'USEPA National Functional Guidelines' as generally applied to the analysis of volatile organic compounds in air. A rules-based, logic driven, independent validation engine was employed to assess completeness, evaluate pass/fail of relevant project quality control requirements and verification of all quantified amounts. Receiving Notes According to the Chain of Custody (COC), samples Till and Alluvium were collected on 1/10/17. However, the date on the sample tag reflects a collection date of 1/10/16. Therefore the date on the COC was used to calculate the sample holding time. Analytical Notes There were no analytical discrepancies. Definition of Data Qualifying Flags Eight qualifiers may have been used on the data analysis sheets and indicates as follows: B - present in laboratory blank greater than reporting limit (background subtraction not performed). J - Estimated value. E - Exceeds instrument calibration range. S - Saturated peak. Q - Exceeds quality control limits. U - analyzed for but not detected above the reporting limit, LOD, or MDL value. See data page for project specific U-flag definition. UJ- Non-detected compound associated with low bias in the CCV N - The identification is based on presumptive evidence. File extensions may have been used on the data analysis sheets and indicates as follows: a-file was requantified b-file was quantified by a second column and detector r1-file was requantified for the purpose of reissue Page 3 of 16
179 Summary of Detected s Client Sample ID: Till Lab ID#: A cis-1,2-dichloroethene 1,1,1-Trichloroethane Trichloroethene 1,1,2-Trichloroethane Tetrachloroethene Client Sample ID: Alluvium Lab ID#: A Freon 12 2-Propanol 1,1,1-Trichloroethane Trichloroethene 1,1,2-Trichloroethane Tetrachloroethene Page 4 of 16
180 File Name: Dil. Factor: 1.86 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Till Lab ID#: A Date of Collection: 1/10/17 10:50:00 AM Date of Analysis: 1/25/17 03:20 AM 0.93 Not Detected 4.6 Not Detected 0.93 Not Detected 6.5 Not Detected 9.3 Not Detected 19 Not Detected 0.93 Not Detected 2.4 Not Detected 0.93 Not Detected 2.0 Not Detected 9.3 Not Detected 36 Not Detected 3.7 Not Detected 9.8 Not Detected 0.93 Not Detected 5.2 Not Detected 3.7 Not Detected 7.0 Not Detected 0.93 Not Detected 7.1 Not Detected 0.93 Not Detected 3.7 Not Detected 9.3 Not Detected 22 Not Detected 3.7 Not Detected 9.1 Not Detected 3.7 Not Detected 12 Not Detected 3.7 Not Detected 12 Not Detected 9.3 Not Detected 32 Not Detected 3.7 Not Detected 13 Not Detected 0.93 Not Detected 3.7 Not Detected 0.93 Not Detected 3.3 Not Detected 0.93 Not Detected 3.8 Not Detected 3.7 Not Detected 11 Not Detected Not Detected 2.7 Not Detected 0.93 Not Detected 4.5 Not Detected Not Detected 3.2 Not Detected 0.93 Not Detected 5.8 Not Detected 0.93 Not Detected 4.3 Not Detected 0.93 Not Detected 3.0 Not Detected 0.93 Not Detected 3.8 Not Detected 0.93 Not Detected 3.8 Not Detected Not Detected 4.3 Not Detected 3.7 Not Detected 13 Not Detected 0.93 Not Detected 6.2 Not Detected 0.93 Not Detected 4.2 Not Detected 0.93 Not Detected 3.8 Not Detected 0.93 Not Detected 3.5 Not Detected 0.93 Not Detected 4.2 Not Detected Not Detected 15 Not Detected Page 5 of 16
181 File Name: Dil. Factor: 1.86 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Till Lab ID#: A Date of Collection: 1/10/17 10:50:00 AM Date of Analysis: 1/25/17 03:20 AM 0.93 Not Detected 7.9 Not Detected 0.93 Not Detected 7.1 Not Detected 0.93 Not Detected 4.3 Not Detected 0.93 Not Detected 4.0 Not Detected 0.93 Not Detected 4.0 Not Detected 0.93 Not Detected 4.0 Not Detected 0.93 Not Detected 4.0 Not Detected 0.93 Not Detected 9.6 Not Detected 0.93 Not Detected 4.6 Not Detected 0.93 Not Detected 6.4 Not Detected 0.93 Not Detected 4.6 Not Detected 0.93 Not Detected 4.6 Not Detected 0.93 Not Detected 4.6 Not Detected 0.93 Not Detected 4.6 Not Detected 0.93 Not Detected 5.6 Not Detected 0.93 Not Detected 5.6 Not Detected 0.93 Not Detected 4.8 Not Detected 0.93 Not Detected 5.6 Not Detected 3.7 Not Detected 28 Not Detected 3.7 Not Detected 40 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 6 of 16
182 File Name: Dil. Factor: 1.86 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Alluvium Lab ID#: A Date of Collection: 1/10/17 11:00:00 AM Date of Analysis: 1/25/17 03:48 AM Not Detected 6.5 Not Detected 9.3 Not Detected 19 Not Detected 0.93 Not Detected 2.4 Not Detected 0.93 Not Detected 2.0 Not Detected 9.3 Not Detected 36 Not Detected 3.7 Not Detected 9.8 Not Detected 0.93 Not Detected 5.2 Not Detected 3.7 Not Detected 7.0 Not Detected 0.93 Not Detected 7.1 Not Detected 0.93 Not Detected 3.7 Not Detected 9.3 Not Detected 22 Not Detected Not Detected 12 Not Detected 3.7 Not Detected 12 Not Detected 9.3 Not Detected 32 Not Detected 3.7 Not Detected 13 Not Detected 0.93 Not Detected 3.7 Not Detected 0.93 Not Detected 3.3 Not Detected 0.93 Not Detected 3.8 Not Detected 3.7 Not Detected 11 Not Detected 0.93 Not Detected 3.7 Not Detected 0.93 Not Detected 2.7 Not Detected 0.93 Not Detected 4.5 Not Detected Not Detected 3.2 Not Detected 0.93 Not Detected 5.8 Not Detected 0.93 Not Detected 4.3 Not Detected 0.93 Not Detected 3.0 Not Detected 0.93 Not Detected 3.8 Not Detected 0.93 Not Detected 3.8 Not Detected Not Detected 4.3 Not Detected 3.7 Not Detected 13 Not Detected 0.93 Not Detected 6.2 Not Detected 0.93 Not Detected 4.2 Not Detected 0.93 Not Detected 3.8 Not Detected 0.93 Not Detected 3.5 Not Detected 0.93 Not Detected 4.2 Not Detected Not Detected 15 Not Detected Page 7 of 16
183 File Name: Dil. Factor: 1.86 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Alluvium Lab ID#: A Date of Collection: 1/10/17 11:00:00 AM Date of Analysis: 1/25/17 03:48 AM 0.93 Not Detected 7.9 Not Detected 0.93 Not Detected 7.1 Not Detected 0.93 Not Detected 4.3 Not Detected 0.93 Not Detected 4.0 Not Detected 0.93 Not Detected 4.0 Not Detected 0.93 Not Detected 4.0 Not Detected 0.93 Not Detected 4.0 Not Detected 0.93 Not Detected 9.6 Not Detected 0.93 Not Detected 4.6 Not Detected 0.93 Not Detected 6.4 Not Detected 0.93 Not Detected 4.6 Not Detected 0.93 Not Detected 4.6 Not Detected 0.93 Not Detected 4.6 Not Detected 0.93 Not Detected 4.6 Not Detected 0.93 Not Detected 5.6 Not Detected 0.93 Not Detected 5.6 Not Detected 0.93 Not Detected 4.8 Not Detected 0.93 Not Detected 5.6 Not Detected 3.7 Not Detected 28 Not Detected 3.7 Not Detected 40 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 8 of 16
184 File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 1/24/17 01:49 PM 0.50 Not Detected 2.5 Not Detected 0.50 Not Detected 3.5 Not Detected 5.0 Not Detected 10 Not Detected 0.50 Not Detected 1.3 Not Detected 0.50 Not Detected 1.1 Not Detected 5.0 Not Detected 19 Not Detected 2.0 Not Detected 5.3 Not Detected 0.50 Not Detected 2.8 Not Detected 2.0 Not Detected 3.8 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.0 Not Detected 5.0 Not Detected 12 Not Detected 2.0 Not Detected 4.9 Not Detected 2.0 Not Detected 6.2 Not Detected 2.0 Not Detected 6.3 Not Detected 5.0 Not Detected 17 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.8 Not Detected 0.50 Not Detected 2.0 Not Detected 2.0 Not Detected 5.9 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.5 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 1.7 Not Detected 0.50 Not Detected 3.1 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 1.6 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 2.3 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.9 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 3.4 Not Detected 2.0 Not Detected 8.2 Not Detected Page 9 of 16
185 File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 1/24/17 01:49 PM 0.50 Not Detected 4.2 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.1 Not Detected 0.50 Not Detected 5.2 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 2.6 Not Detected 0.50 Not Detected 3.0 Not Detected 2.0 Not Detected 15 Not Detected 2.0 Not Detected 21 Not Detected Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 10 of 16
186 Client Sample ID: CCV Lab ID#: A File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/24/17 09:47 AM Page 11 of 16
187 Client Sample ID: CCV Lab ID#: A File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/24/17 09:47 AM Page 12 of 16
188 Client Sample ID: LCS Lab ID#: A File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/24/17 10:16 AM Page 13 of 16
189 Client Sample ID: LCS Lab ID#: A File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/24/17 10:16 AM Page 14 of 16
190 Client Sample ID: LCSD Lab ID#: AA File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/24/17 10:43 AM Page 15 of 16
191 Client Sample ID: LCSD Lab ID#: AA File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/24/17 10:43 AM Page 16 of 16
192
193 2/2/2017 Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan MN Project Name: Shoreham Yards Project #: Workorder #: Dear Mr. Brian Deering The following report includes the data for the above referenced project for sample(s) received on 1/24/2017 at Air Toxics Ltd. The data and associated QC analyzed by TO-15 are compliant with the project requirements or laboratory criteria with the exception of the deviations noted in the attached case narrative. Thank you for choosing Eurofins Air Toxics Inc. for your air analysis needs. Eurofins Air Toxics Inc. is committed to providing accurate data of the highest quality. Please feel free to contact the Project Manager: Ausha Scott at if you have any questions regarding the data in this report. Regards, Ausha Scott Project Manager Page 1 of 16
194 WORK ORDER #: Work Order Summary CLIENT: PHONE: FAX: Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan, MN DATE RECEIVED: 01/24/2017 DATE COMPLETED: 02/02/2017 BILL TO: PROJECT # CONTACT: Accounts Payable Groundwater & Environmental Services, Inc. (GES) 1350 Blair Drive, Suite A Odenton, MD P.O. # Shoreham Yards Ausha Scott RECEIPT FRACTION # NAME TEST VAC./PRES. FINAL PRESSURE 01A Till TO "Hg 4.9 psi 02A Alluvium TO "Hg 4.8 psi 03A Lab Blank TO-15 NA NA 04A CCV TO-15 NA NA 05A LCS TO-15 NA NA 05AA LCSD TO-15 NA NA CERTIFIED BY: DATE: 02/02/17 Technical Director Certification numbers: AZ Licensure AZ0775, NJ NELAP - CA016, NY NELAP , TX NELAP - T , UT NELAP CA , VA NELAP , WA NELAP - C935 Name of Accreditation Body: NELAP/ORELAP (Oregon Environmental Laboratory Accreditation Program) Accreditation number: CA300005, Effective date: 10/18/2016, Expiration date: 10/17/2017. Eurofins Air Toxics Inc.. certifies that the test results contained in this report meet all requirements of the NELAC standards This report shall not be reproduced, except in full, without the written approval of Eurofins Air Toxics, Inc. 180 BLUE RAVINE ROAD, SUITE B FOLSOM, CA (916) (800) FAX (916) Page 2 of 16
195 LABORATORY NARRATIVE EPA TO-15 Groundwater & Environmental Services, Inc. (GES) Workorder# Two 6 Liter Summa Canister samples were received on January 24, The laboratory performed analysis via EPA TO-15 using GC/MS in the full scan mode. This workorder was independently validated prior to submittal using 'USEPA National Functional Guidelines' as generally applied to the analysis of volatile organic compounds in air. A rules-based, logic driven, independent validation engine was employed to assess completeness, evaluate pass/fail of relevant project quality control requirements and verification of all quantified amounts. Receiving Notes There were no receiving discrepancies. Analytical Notes There were no analytical discrepancies. Definition of Data Qualifying Flags Eight qualifiers may have been used on the data analysis sheets and indicates as follows: B - present in laboratory blank greater than reporting limit (background subtraction not performed). J - Estimated value. E - Exceeds instrument calibration range. S - Saturated peak. Q - Exceeds quality control limits. U - analyzed for but not detected above the reporting limit, LOD, or MDL value. See data page for project specific U-flag definition. UJ- Non-detected compound associated with low bias in the CCV N - The identification is based on presumptive evidence. File extensions may have been used on the data analysis sheets and indicates as follows: a-file was requantified b-file was quantified by a second column and detector r1-file was requantified for the purpose of reissue Page 3 of 16
196 Summary of Detected s Client Sample ID: Till Lab ID#: A Ethanol 1,1-Dichloroethane cis-1,2-dichloroethene 1,1,1-Trichloroethane Trichloroethene 1,1,2-Trichloroethane Tetrachloroethene J J Client Sample ID: Alluvium Lab ID#: A 1,1,1-Trichloroethane Trichloroethene Tetrachloroethene Page 4 of 16
197 File Name: a Dil. Factor: 1.67 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Till Lab ID#: A Date of Collection: 1/17/17 2:10:00 PM Date of Analysis: 1/27/17 09:20 PM 0.84 Not Detected 4.1 Not Detected 0.84 Not Detected 5.8 Not Detected 8.4 Not Detected 17 Not Detected 0.84 Not Detected 2.1 Not Detected 0.84 Not Detected 1.8 Not Detected 8.4 Not Detected 32 Not Detected 3.3 Not Detected 8.8 Not Detected 0.84 Not Detected 4.7 Not Detected Not Detected 6.4 Not Detected 0.84 Not Detected 3.3 Not Detected 8.4 Not Detected 20 Not Detected 3.3 Not Detected 8.2 Not Detected 3.3 Not Detected 10 Not Detected 3.3 Not Detected 10 Not Detected 8.4 Not Detected 29 Not Detected 3.3 Not Detected 12 Not Detected 0.84 Not Detected 3.3 Not Detected 0.84 Not Detected 2.9 Not Detected J J 3.3 Not Detected 9.8 Not Detected Not Detected 2.5 Not Detected 0.84 Not Detected 4.1 Not Detected Not Detected 2.9 Not Detected 0.84 Not Detected 5.2 Not Detected 0.84 Not Detected 3.9 Not Detected 0.84 Not Detected 2.7 Not Detected 0.84 Not Detected 3.4 Not Detected 0.84 Not Detected 3.4 Not Detected Not Detected 3.8 Not Detected 3.3 Not Detected 12 Not Detected 0.84 Not Detected 5.6 Not Detected 0.84 Not Detected 3.8 Not Detected 0.84 Not Detected 3.4 Not Detected 0.84 Not Detected 3.1 Not Detected 0.84 Not Detected 3.8 Not Detected Not Detected 14 Not Detected Page 5 of 16
198 File Name: a Dil. Factor: 1.67 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Till Lab ID#: A Date of Collection: 1/17/17 2:10:00 PM Date of Analysis: 1/27/17 09:20 PM 0.84 Not Detected 7.1 Not Detected 0.84 Not Detected 6.4 Not Detected 0.84 Not Detected 3.8 Not Detected 0.84 Not Detected 3.6 Not Detected 0.84 Not Detected 3.6 Not Detected 0.84 Not Detected 3.6 Not Detected 0.84 Not Detected 3.6 Not Detected 0.84 Not Detected 8.6 Not Detected 0.84 Not Detected 4.1 Not Detected 0.84 Not Detected 5.7 Not Detected 0.84 Not Detected 4.1 Not Detected 0.84 Not Detected 4.1 Not Detected 0.84 Not Detected 4.1 Not Detected 0.84 Not Detected 4.1 Not Detected 0.84 Not Detected 5.0 Not Detected 0.84 Not Detected 5.0 Not Detected 0.84 Not Detected 4.3 Not Detected 0.84 Not Detected 5.0 Not Detected 3.3 Not Detected 25 Not Detected 3.3 Not Detected 36 Not Detected J = Estimated value. Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 6 of 16
199 File Name: a Dil. Factor: 1.60 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Alluvium Lab ID#: A Date of Collection: 1/17/17 2:20:00 PM Date of Analysis: 1/27/17 09:46 PM 0.80 Not Detected 4.0 Not Detected 0.80 Not Detected 5.6 Not Detected 8.0 Not Detected 16 Not Detected 0.80 Not Detected 2.0 Not Detected 0.80 Not Detected 1.8 Not Detected 8.0 Not Detected 31 Not Detected 3.2 Not Detected 8.4 Not Detected 0.80 Not Detected 4.5 Not Detected 3.2 Not Detected 6.0 Not Detected 0.80 Not Detected 6.1 Not Detected 0.80 Not Detected 3.2 Not Detected 8.0 Not Detected 19 Not Detected 3.2 Not Detected 7.9 Not Detected 3.2 Not Detected 10 Not Detected 3.2 Not Detected 10 Not Detected 8.0 Not Detected 28 Not Detected 3.2 Not Detected 12 Not Detected 0.80 Not Detected 3.2 Not Detected 0.80 Not Detected 2.8 Not Detected 0.80 Not Detected 3.2 Not Detected 3.2 Not Detected 9.4 Not Detected 0.80 Not Detected 3.2 Not Detected 0.80 Not Detected 2.4 Not Detected 0.80 Not Detected 3.9 Not Detected Not Detected 2.8 Not Detected 0.80 Not Detected 5.0 Not Detected 0.80 Not Detected 3.7 Not Detected 0.80 Not Detected 2.6 Not Detected 0.80 Not Detected 3.2 Not Detected 0.80 Not Detected 3.3 Not Detected Not Detected 3.7 Not Detected 3.2 Not Detected 12 Not Detected 0.80 Not Detected 5.4 Not Detected 0.80 Not Detected 3.6 Not Detected 0.80 Not Detected 3.3 Not Detected 0.80 Not Detected 3.0 Not Detected 0.80 Not Detected 3.6 Not Detected 0.80 Not Detected 4.4 Not Detected Not Detected 13 Not Detected Page 7 of 16
200 File Name: a Dil. Factor: 1.60 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Alluvium Lab ID#: A Date of Collection: 1/17/17 2:20:00 PM Date of Analysis: 1/27/17 09:46 PM 0.80 Not Detected 6.8 Not Detected 0.80 Not Detected 6.1 Not Detected 0.80 Not Detected 3.7 Not Detected 0.80 Not Detected 3.5 Not Detected 0.80 Not Detected 3.5 Not Detected 0.80 Not Detected 3.5 Not Detected 0.80 Not Detected 3.4 Not Detected 0.80 Not Detected 8.3 Not Detected 0.80 Not Detected 3.9 Not Detected 0.80 Not Detected 5.5 Not Detected 0.80 Not Detected 3.9 Not Detected 0.80 Not Detected 3.9 Not Detected 0.80 Not Detected 3.9 Not Detected 0.80 Not Detected 3.9 Not Detected 0.80 Not Detected 4.8 Not Detected 0.80 Not Detected 4.8 Not Detected 0.80 Not Detected 4.1 Not Detected 0.80 Not Detected 4.8 Not Detected 3.2 Not Detected 24 Not Detected 3.2 Not Detected 34 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 8 of 16
201 File Name: a Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 1/27/17 12:44 PM 0.50 Not Detected 2.5 Not Detected 0.50 Not Detected 3.5 Not Detected 5.0 Not Detected 10 Not Detected 0.50 Not Detected 1.3 Not Detected 0.50 Not Detected 1.1 Not Detected 5.0 Not Detected 19 Not Detected 2.0 Not Detected 5.3 Not Detected 0.50 Not Detected 2.8 Not Detected 2.0 Not Detected 3.8 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.0 Not Detected 5.0 Not Detected 12 Not Detected 2.0 Not Detected 4.9 Not Detected 2.0 Not Detected 6.2 Not Detected 2.0 Not Detected 6.3 Not Detected 5.0 Not Detected 17 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.8 Not Detected 0.50 Not Detected 2.0 Not Detected 2.0 Not Detected 5.9 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.5 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 1.7 Not Detected 0.50 Not Detected 3.1 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 1.6 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 2.3 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.9 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 3.4 Not Detected 2.0 Not Detected 8.2 Not Detected Page 9 of 16
202 File Name: a Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 1/27/17 12:44 PM 0.50 Not Detected 4.2 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.1 Not Detected 0.50 Not Detected 5.2 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 2.6 Not Detected 0.50 Not Detected 3.0 Not Detected 2.0 Not Detected 15 Not Detected 2.0 Not Detected 21 Not Detected Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 10 of 16
203 Client Sample ID: CCV Lab ID#: A File Name: a Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/27/17 08:36 AM Page 11 of 16
204 Client Sample ID: CCV Lab ID#: A File Name: a Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/27/17 08:36 AM Page 12 of 16
205 Client Sample ID: LCS Lab ID#: A File Name: a Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/27/17 09:01 AM Page 13 of 16
206 Client Sample ID: LCS Lab ID#: A File Name: a Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/27/17 09:01 AM Page 14 of 16
207 Client Sample ID: LCSD Lab ID#: AA File Name: a Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/27/17 09:26 AM Page 15 of 16
208 Client Sample ID: LCSD Lab ID#: AA File Name: a Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/27/17 09:26 AM Page 16 of 16
209
210 2/2/2017 Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan MN Project Name: Shoreham Yards Project #: Workorder #: Dear Mr. Brian Deering The following report includes the data for the above referenced project for sample(s) received on 1/24/2017 at Air Toxics Ltd. The data and associated QC analyzed by TO-15 are compliant with the project requirements or laboratory criteria with the exception of the deviations noted in the attached case narrative. Thank you for choosing Eurofins Air Toxics Inc. for your air analysis needs. Eurofins Air Toxics Inc. is committed to providing accurate data of the highest quality. Please feel free to contact the Project Manager: Ausha Scott at if you have any questions regarding the data in this report. Regards, Ausha Scott Project Manager Page 1 of 16
211 WORK ORDER #: Work Order Summary CLIENT: PHONE: FAX: Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan, MN DATE RECEIVED: 01/24/2017 DATE COMPLETED: 02/02/2017 BILL TO: PROJECT # CONTACT: Accounts Payable Groundwater & Environmental Services, Inc. (GES) 1350 Blair Drive, Suite A Odenton, MD P.O. # Shoreham Yards Ausha Scott RECEIPT FRACTION # NAME TEST VAC./PRES. FINAL PRESSURE 01A Till TO "Hg 4.9 psi 02A Alluvium TO "Hg 5 psi 03A Lab Blank TO-15 NA NA 04A CCV TO-15 NA NA 05A LCS TO-15 NA NA 05AA LCSD TO-15 NA NA CERTIFIED BY: DATE: 02/02/17 Technical Director Certification numbers: AZ Licensure AZ0775, NJ NELAP - CA016, NY NELAP , TX NELAP - T , UT NELAP CA , VA NELAP , WA NELAP - C935 Name of Accreditation Body: NELAP/ORELAP (Oregon Environmental Laboratory Accreditation Program) Accreditation number: CA300005, Effective date: 10/18/2016, Expiration date: 10/17/2017. Eurofins Air Toxics Inc.. certifies that the test results contained in this report meet all requirements of the NELAC standards This report shall not be reproduced, except in full, without the written approval of Eurofins Air Toxics, Inc. 180 BLUE RAVINE ROAD, SUITE B FOLSOM, CA (916) (800) FAX (916) Page 2 of 16
212 LABORATORY NARRATIVE EPA TO-15 Groundwater & Environmental Services, Inc. (GES) Workorder# Two 6 Liter Summa Canister samples were received on January 24, The laboratory performed analysis via EPA TO-15 using GC/MS in the full scan mode. This workorder was independently validated prior to submittal using 'USEPA National Functional Guidelines' as generally applied to the analysis of volatile organic compounds in air. A rules-based, logic driven, independent validation engine was employed to assess completeness, evaluate pass/fail of relevant project quality control requirements and verification of all quantified amounts. Receiving Notes There were no receiving discrepancies. Analytical Notes There were no analytical discrepancies. Definition of Data Qualifying Flags Eight qualifiers may have been used on the data analysis sheets and indicates as follows: B - present in laboratory blank greater than reporting limit (background subtraction not performed). J - Estimated value. E - Exceeds instrument calibration range. S - Saturated peak. Q - Exceeds quality control limits. U - analyzed for but not detected above the reporting limit, LOD, or MDL value. See data page for project specific U-flag definition. UJ- Non-detected compound associated with low bias in the CCV N - The identification is based on presumptive evidence. File extensions may have been used on the data analysis sheets and indicates as follows: a-file was requantified b-file was quantified by a second column and detector r1-file was requantified for the purpose of reissue Page 3 of 16
213 Summary of Detected s Client Sample ID: Till Lab ID#: A Ethanol Acetone 2-Propanol 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene 1,1,1-Trichloroethane Benzene Trichloroethene Toluene 1,1,2-Trichloroethane Tetrachloroethene m,p-xylene Client Sample ID: Alluvium Lab ID#: A cis-1,2-dichloroethene 1,1,1-Trichloroethane Trichloroethene 1,1,2-Trichloroethane Tetrachloroethene Page 4 of 16
214 File Name: a Dil. Factor: 1.76 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Till Lab ID#: A Date of Collection: 1/18/17 1:30:00 PM Date of Analysis: 1/27/17 07:21 PM 0.88 Not Detected 4.4 Not Detected 0.88 Not Detected 6.2 Not Detected 8.8 Not Detected 18 Not Detected 0.88 Not Detected 2.2 Not Detected 0.88 Not Detected 1.9 Not Detected 8.8 Not Detected 34 Not Detected 3.5 Not Detected 9.3 Not Detected 0.88 Not Detected 4.9 Not Detected Not Detected 6.7 Not Detected 0.88 Not Detected 3.5 Not Detected Not Detected 11 Not Detected 3.5 Not Detected 11 Not Detected 8.8 Not Detected 30 Not Detected 3.5 Not Detected 13 Not Detected 0.88 Not Detected 3.5 Not Detected 0.88 Not Detected 3.1 Not Detected 0.88 Not Detected 3.6 Not Detected Not Detected 2.6 Not Detected 0.88 Not Detected 4.3 Not Detected Not Detected 3.0 Not Detected 0.88 Not Detected 5.5 Not Detected 0.88 Not Detected 4.1 Not Detected Not Detected 3.6 Not Detected 0.88 Not Detected 3.6 Not Detected Not Detected 4.1 Not Detected 3.5 Not Detected 13 Not Detected 0.88 Not Detected 5.9 Not Detected 0.88 Not Detected 4.0 Not Detected 0.88 Not Detected 3.6 Not Detected Not Detected 4.0 Not Detected Not Detected 14 Not Detected Page 5 of 16
215 File Name: a Dil. Factor: 1.76 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Till Lab ID#: A Date of Collection: 1/18/17 1:30:00 PM Date of Analysis: 1/27/17 07:21 PM 0.88 Not Detected 7.5 Not Detected 0.88 Not Detected 6.8 Not Detected 0.88 Not Detected 4.0 Not Detected 0.88 Not Detected 3.8 Not Detected Not Detected 3.8 Not Detected 0.88 Not Detected 3.7 Not Detected 0.88 Not Detected 9.1 Not Detected 0.88 Not Detected 4.3 Not Detected 0.88 Not Detected 6.0 Not Detected 0.88 Not Detected 4.3 Not Detected 0.88 Not Detected 4.3 Not Detected 0.88 Not Detected 4.3 Not Detected 0.88 Not Detected 4.3 Not Detected 0.88 Not Detected 5.3 Not Detected 0.88 Not Detected 5.3 Not Detected 0.88 Not Detected 4.6 Not Detected 0.88 Not Detected 5.3 Not Detected 3.5 Not Detected 26 Not Detected 3.5 Not Detected 38 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 6 of 16
216 File Name: a Dil. Factor: 1.61 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Alluvium Lab ID#: A Date of Collection: 1/18/17 1:45:00 PM Date of Analysis: 1/27/17 06:54 PM 0.80 Not Detected 4.0 Not Detected 0.80 Not Detected 5.6 Not Detected 8.0 Not Detected 17 Not Detected 0.80 Not Detected 2.0 Not Detected 0.80 Not Detected 1.8 Not Detected 8.0 Not Detected 31 Not Detected 3.2 Not Detected 8.5 Not Detected 0.80 Not Detected 4.5 Not Detected 3.2 Not Detected 6.1 Not Detected 0.80 Not Detected 6.2 Not Detected 0.80 Not Detected 3.2 Not Detected 8.0 Not Detected 19 Not Detected 3.2 Not Detected 7.9 Not Detected 3.2 Not Detected 10 Not Detected 3.2 Not Detected 10 Not Detected 8.0 Not Detected 28 Not Detected 3.2 Not Detected 12 Not Detected 0.80 Not Detected 3.2 Not Detected 0.80 Not Detected 2.8 Not Detected 0.80 Not Detected 3.2 Not Detected 3.2 Not Detected 9.5 Not Detected Not Detected 2.4 Not Detected 0.80 Not Detected 3.9 Not Detected Not Detected 2.8 Not Detected 0.80 Not Detected 5.1 Not Detected 0.80 Not Detected 3.8 Not Detected 0.80 Not Detected 2.6 Not Detected 0.80 Not Detected 3.2 Not Detected 0.80 Not Detected 3.3 Not Detected Not Detected 3.7 Not Detected 3.2 Not Detected 12 Not Detected 0.80 Not Detected 5.4 Not Detected 0.80 Not Detected 3.6 Not Detected 0.80 Not Detected 3.3 Not Detected 0.80 Not Detected 3.0 Not Detected 0.80 Not Detected 3.6 Not Detected Not Detected 13 Not Detected Page 7 of 16
217 File Name: a Dil. Factor: 1.61 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Alluvium Lab ID#: A Date of Collection: 1/18/17 1:45:00 PM Date of Analysis: 1/27/17 06:54 PM 0.80 Not Detected 6.8 Not Detected 0.80 Not Detected 6.2 Not Detected 0.80 Not Detected 3.7 Not Detected 0.80 Not Detected 3.5 Not Detected 0.80 Not Detected 3.5 Not Detected 0.80 Not Detected 3.5 Not Detected 0.80 Not Detected 3.4 Not Detected 0.80 Not Detected 8.3 Not Detected 0.80 Not Detected 4.0 Not Detected 0.80 Not Detected 5.5 Not Detected 0.80 Not Detected 4.0 Not Detected 0.80 Not Detected 4.0 Not Detected 0.80 Not Detected 4.0 Not Detected 0.80 Not Detected 4.0 Not Detected 0.80 Not Detected 4.8 Not Detected 0.80 Not Detected 4.8 Not Detected 0.80 Not Detected 4.2 Not Detected 0.80 Not Detected 4.8 Not Detected 3.2 Not Detected 24 Not Detected 3.2 Not Detected 34 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 8 of 16
218 File Name: a Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 1/27/17 12:44 PM 0.50 Not Detected 2.5 Not Detected 0.50 Not Detected 3.5 Not Detected 5.0 Not Detected 10 Not Detected 0.50 Not Detected 1.3 Not Detected 0.50 Not Detected 1.1 Not Detected 5.0 Not Detected 19 Not Detected 2.0 Not Detected 5.3 Not Detected 0.50 Not Detected 2.8 Not Detected 2.0 Not Detected 3.8 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.0 Not Detected 5.0 Not Detected 12 Not Detected 2.0 Not Detected 4.9 Not Detected 2.0 Not Detected 6.2 Not Detected 2.0 Not Detected 6.3 Not Detected 5.0 Not Detected 17 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.8 Not Detected 0.50 Not Detected 2.0 Not Detected 2.0 Not Detected 5.9 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.5 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 1.7 Not Detected 0.50 Not Detected 3.1 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 1.6 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 2.3 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.9 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 3.4 Not Detected 2.0 Not Detected 8.2 Not Detected Page 9 of 16
219 File Name: a Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 1/27/17 12:44 PM 0.50 Not Detected 4.2 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.1 Not Detected 0.50 Not Detected 5.2 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 2.6 Not Detected 0.50 Not Detected 3.0 Not Detected 2.0 Not Detected 15 Not Detected 2.0 Not Detected 21 Not Detected Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 10 of 16
220 Client Sample ID: CCV Lab ID#: A File Name: a Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/27/17 08:36 AM Page 11 of 16
221 Client Sample ID: CCV Lab ID#: A File Name: a Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/27/17 08:36 AM Page 12 of 16
222 Client Sample ID: LCS Lab ID#: A File Name: a Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/27/17 09:01 AM Page 13 of 16
223 Client Sample ID: LCS Lab ID#: A File Name: a Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/27/17 09:01 AM Page 14 of 16
224 Client Sample ID: LCSD Lab ID#: AA File Name: a Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/27/17 09:26 AM Page 15 of 16
225 Client Sample ID: LCSD Lab ID#: AA File Name: a Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/27/17 09:26 AM Page 16 of 16
226
227 2/7/2017 Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan MN Project Name: Shoreham Yards Project #: Workorder #: Dear Mr. Brian Deering The following report includes the data for the above referenced project for sample(s) received on 1/27/2017 at Air Toxics Ltd. The data and associated QC analyzed by TO-15 are compliant with the project requirements or laboratory criteria with the exception of the deviations noted in the attached case narrative. Thank you for choosing Eurofins Air Toxics Inc. for your air analysis needs. Eurofins Air Toxics Inc. is committed to providing accurate data of the highest quality. Please feel free to contact the Project Manager: Ausha Scott at if you have any questions regarding the data in this report. Regards, Ausha Scott Project Manager Page 1 of 16
228 WORK ORDER #: Work Order Summary CLIENT: PHONE: FAX: Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan, MN DATE RECEIVED: 01/27/2017 DATE COMPLETED: 02/03/2017 BILL TO: PROJECT # CONTACT: Accounts Payable Groundwater & Environmental Services, Inc. (GES) 1350 Blair Drive, Suite A Odenton, MD P.O. # Shoreham Yards Ausha Scott RECEIPT FRACTION # NAME TEST VAC./PRES. FINAL PRESSURE 01A Till TO "Hg 4.9 psi 02A Alluvium TO "Hg 4.8 psi 03A Lab Blank TO-15 NA NA 04A CCV TO-15 NA NA 05A LCS TO-15 NA NA 05AA LCSD TO-15 NA NA CERTIFIED BY: DATE: 02/07/17 Technical Director Certification numbers: AZ Licensure AZ0775, NJ NELAP - CA016, NY NELAP , TX NELAP - T , UT NELAP CA , VA NELAP , WA NELAP - C935 Name of Accreditation Body: NELAP/ORELAP (Oregon Environmental Laboratory Accreditation Program) Accreditation number: CA300005, Effective date: 10/18/2016, Expiration date: 10/17/2017. Eurofins Air Toxics Inc.. certifies that the test results contained in this report meet all requirements of the NELAC standards This report shall not be reproduced, except in full, without the written approval of Eurofins Air Toxics, Inc. 180 BLUE RAVINE ROAD, SUITE B FOLSOM, CA (916) (800) FAX (916) Page 2 of 16
229 LABORATORY NARRATIVE EPA TO-15 Groundwater & Environmental Services, Inc. (GES) Workorder# Two 6 Liter Summa Canister samples were received on January 27, The laboratory performed analysis via EPA TO-15 using GC/MS in the full scan mode. This workorder was independently validated prior to submittal using 'USEPA National Functional Guidelines' as generally applied to the analysis of volatile organic compounds in air. A rules-based, logic driven, independent validation engine was employed to assess completeness, evaluate pass/fail of relevant project quality control requirements and verification of all quantified amounts. Receiving Notes There were no receiving discrepancies. Analytical Notes There were no analytical discrepancies. Definition of Data Qualifying Flags Eight qualifiers may have been used on the data analysis sheets and indicates as follows: B - present in laboratory blank greater than reporting limit (background subtraction not performed). J - Estimated value. E - Exceeds instrument calibration range. S - Saturated peak. Q - Exceeds quality control limits. U - analyzed for but not detected above the reporting limit, LOD, or MDL value. See data page for project specific U-flag definition. UJ- Non-detected compound associated with low bias in the CCV N - The identification is based on presumptive evidence. File extensions may have been used on the data analysis sheets and indicates as follows: a-file was requantified b-file was quantified by a second column and detector r1-file was requantified for the purpose of reissue Page 3 of 16
230 Summary of Detected s Client Sample ID: Till Lab ID#: A Ethanol Acetone 2-Propanol 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene 1,1,1-Trichloroethane Trichloroethene 1,1,2-Trichloroethane Tetrachloroethene m,p-xylene Client Sample ID: Alluvium Lab ID#: A Ethanol Acetone 2-Propanol 2-Butanone (Methyl Ethyl Ketone) Tetrahydrofuran 1,1,1-Trichloroethane Benzene Trichloroethene Tetrachloroethene Page 4 of 16
231 File Name: Dil. Factor: 1.72 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Till Lab ID#: A Date of Collection: 1/20/17 11:00:00 AM Date of Analysis: 2/1/17 02:21 AM 0.86 Not Detected 4.2 Not Detected 0.86 Not Detected 6.0 Not Detected 8.6 Not Detected 18 Not Detected 0.86 Not Detected 2.2 Not Detected 0.86 Not Detected 1.9 Not Detected 8.6 Not Detected 33 Not Detected 3.4 Not Detected 9.1 Not Detected 0.86 Not Detected 4.8 Not Detected Not Detected 6.6 Not Detected 0.86 Not Detected 3.4 Not Detected Not Detected 11 Not Detected 3.4 Not Detected 11 Not Detected 8.6 Not Detected 30 Not Detected 3.4 Not Detected 12 Not Detected 0.86 Not Detected 3.4 Not Detected 0.86 Not Detected 3.0 Not Detected 0.86 Not Detected 3.5 Not Detected Not Detected 2.5 Not Detected 0.86 Not Detected 4.2 Not Detected Not Detected 3.0 Not Detected 0.86 Not Detected 5.4 Not Detected 0.86 Not Detected 4.0 Not Detected 0.86 Not Detected 2.7 Not Detected 0.86 Not Detected 3.5 Not Detected 0.86 Not Detected 3.5 Not Detected Not Detected 4.0 Not Detected 3.4 Not Detected 12 Not Detected 0.86 Not Detected 5.8 Not Detected 0.86 Not Detected 3.9 Not Detected 0.86 Not Detected 3.5 Not Detected 0.86 Not Detected 3.2 Not Detected 0.86 Not Detected 3.9 Not Detected Not Detected 14 Not Detected Page 5 of 16
232 File Name: Dil. Factor: 1.72 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Till Lab ID#: A Date of Collection: 1/20/17 11:00:00 AM Date of Analysis: 2/1/17 02:21 AM 0.86 Not Detected 7.3 Not Detected 0.86 Not Detected 6.6 Not Detected 0.86 Not Detected 4.0 Not Detected 0.86 Not Detected 3.7 Not Detected Not Detected 3.7 Not Detected 0.86 Not Detected 3.7 Not Detected 0.86 Not Detected 8.9 Not Detected 0.86 Not Detected 4.2 Not Detected 0.86 Not Detected 5.9 Not Detected 0.86 Not Detected 4.2 Not Detected 0.86 Not Detected 4.2 Not Detected 0.86 Not Detected 4.2 Not Detected 0.86 Not Detected 4.2 Not Detected 0.86 Not Detected 5.2 Not Detected 0.86 Not Detected 5.2 Not Detected 0.86 Not Detected 4.4 Not Detected 0.86 Not Detected 5.2 Not Detected 3.4 Not Detected 26 Not Detected 3.4 Not Detected 37 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 6 of 16
233 File Name: Dil. Factor: 1.58 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Alluvium Lab ID#: A Date of Collection: 1/20/17 11:15:00 AM Date of Analysis: 2/1/17 02:49 AM 0.79 Not Detected 3.9 Not Detected 0.79 Not Detected 5.5 Not Detected 7.9 Not Detected 16 Not Detected 0.79 Not Detected 2.0 Not Detected 0.79 Not Detected 1.7 Not Detected 7.9 Not Detected 31 Not Detected 3.2 Not Detected 8.3 Not Detected 0.79 Not Detected 4.4 Not Detected Not Detected 6.0 Not Detected 0.79 Not Detected 3.1 Not Detected Not Detected 9.8 Not Detected 3.2 Not Detected 9.9 Not Detected 7.9 Not Detected 27 Not Detected 3.2 Not Detected 11 Not Detected 0.79 Not Detected 3.1 Not Detected 0.79 Not Detected 2.8 Not Detected 0.79 Not Detected 3.2 Not Detected Not Detected 3.1 Not Detected Not Detected 3.8 Not Detected Not Detected 2.7 Not Detected 0.79 Not Detected 5.0 Not Detected 0.79 Not Detected 3.7 Not Detected Not Detected 3.2 Not Detected 0.79 Not Detected 3.2 Not Detected Not Detected 3.6 Not Detected 3.2 Not Detected 11 Not Detected 0.79 Not Detected 5.3 Not Detected 0.79 Not Detected 3.6 Not Detected 0.79 Not Detected 3.2 Not Detected 0.79 Not Detected 3.0 Not Detected 0.79 Not Detected 3.6 Not Detected 0.79 Not Detected 4.3 Not Detected Not Detected 13 Not Detected Page 7 of 16
234 File Name: Dil. Factor: 1.58 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Alluvium Lab ID#: A Date of Collection: 1/20/17 11:15:00 AM Date of Analysis: 2/1/17 02:49 AM 0.79 Not Detected 6.7 Not Detected 0.79 Not Detected 6.1 Not Detected 0.79 Not Detected 3.6 Not Detected 0.79 Not Detected 3.4 Not Detected 0.79 Not Detected 3.4 Not Detected 0.79 Not Detected 3.4 Not Detected 0.79 Not Detected 3.4 Not Detected 0.79 Not Detected 8.2 Not Detected 0.79 Not Detected 3.9 Not Detected 0.79 Not Detected 5.4 Not Detected 0.79 Not Detected 3.9 Not Detected 0.79 Not Detected 3.9 Not Detected 0.79 Not Detected 3.9 Not Detected 0.79 Not Detected 3.9 Not Detected 0.79 Not Detected 4.8 Not Detected 0.79 Not Detected 4.8 Not Detected 0.79 Not Detected 4.1 Not Detected 0.79 Not Detected 4.7 Not Detected 3.2 Not Detected 23 Not Detected 3.2 Not Detected 34 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 8 of 16
235 File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 1/31/17 04:09 PM 0.50 Not Detected 2.5 Not Detected 0.50 Not Detected 3.5 Not Detected 5.0 Not Detected 10 Not Detected 0.50 Not Detected 1.3 Not Detected 0.50 Not Detected 1.1 Not Detected 5.0 Not Detected 19 Not Detected 2.0 Not Detected 5.3 Not Detected 0.50 Not Detected 2.8 Not Detected 2.0 Not Detected 3.8 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.0 Not Detected 5.0 Not Detected 12 Not Detected 2.0 Not Detected 4.9 Not Detected 2.0 Not Detected 6.2 Not Detected 2.0 Not Detected 6.3 Not Detected 5.0 Not Detected 17 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.8 Not Detected 0.50 Not Detected 2.0 Not Detected 2.0 Not Detected 5.9 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.5 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 1.7 Not Detected 0.50 Not Detected 3.1 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 1.6 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 2.3 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.9 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 3.4 Not Detected 2.0 Not Detected 8.2 Not Detected Page 9 of 16
236 File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 1/31/17 04:09 PM 0.50 Not Detected 4.2 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.1 Not Detected 0.50 Not Detected 5.2 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 2.6 Not Detected 0.50 Not Detected 3.0 Not Detected 2.0 Not Detected 15 Not Detected 2.0 Not Detected 21 Not Detected Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 10 of 16
237 Client Sample ID: CCV Lab ID#: A File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/31/17 09:51 AM Page 11 of 16
238 Client Sample ID: CCV Lab ID#: A File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/31/17 09:51 AM Page 12 of 16
239 Client Sample ID: LCS Lab ID#: A File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/31/17 10:18 AM Page 13 of 16
240 Client Sample ID: LCS Lab ID#: A File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/31/17 10:18 AM Page 14 of 16
241 Client Sample ID: LCSD Lab ID#: AA File Name: Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 1/31/17 10:45 AM Page 15 of 16
242 Client Sample ID: LCSD Lab ID#: AA File Name: Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 1/31/17 10:45 AM Page 16 of 16
243 2/7/2017 Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan MN Project Name: Shoreham Yards Project #: Workorder #: Dear Mr. Brian Deering The following report includes the data for the above referenced project for sample(s) received on 1/27/2017 at Air Toxics Ltd. The data and associated QC analyzed by TO-15 are compliant with the project requirements or laboratory criteria with the exception of the deviations noted in the attached case narrative. Thank you for choosing Eurofins Air Toxics Inc. for your air analysis needs. Eurofins Air Toxics Inc. is committed to providing accurate data of the highest quality. Please feel free to contact the Project Manager: Ausha Scott at if you have any questions regarding the data in this report. Regards, Ausha Scott Project Manager Page 1 of 16
244 WORK ORDER #: Work Order Summary CLIENT: PHONE: FAX: Mr. Brian Deering Groundwater & Environmental Services, Inc. (GES) 1285 Corporate Center Drive Suite 120 Eagan, MN DATE RECEIVED: 01/27/2017 DATE COMPLETED: 02/07/2017 BILL TO: PROJECT # CONTACT: Accounts Payable Groundwater & Environmental Services, Inc. (GES) 1350 Blair Drive, Suite A Odenton, MD P.O. # Shoreham Yards Ausha Scott RECEIPT FRACTION # NAME TEST VAC./PRES. FINAL PRESSURE 01A Till TO "Hg 4.9 psi 02A Alluvium TO "Hg 5.1 psi 03A Lab Blank TO-15 NA NA 04A CCV TO-15 NA NA 05A LCS TO-15 NA NA 05AA LCSD TO-15 NA NA CERTIFIED BY: DATE: 02/07/17 Technical Director Certification numbers: AZ Licensure AZ0775, NJ NELAP - CA016, NY NELAP , TX NELAP - T , UT NELAP CA , VA NELAP , WA NELAP - C935 Name of Accreditation Body: NELAP/ORELAP (Oregon Environmental Laboratory Accreditation Program) Accreditation number: CA300005, Effective date: 10/18/2016, Expiration date: 10/17/2017. Eurofins Air Toxics Inc.. certifies that the test results contained in this report meet all requirements of the NELAC standards This report shall not be reproduced, except in full, without the written approval of Eurofins Air Toxics, Inc. 180 BLUE RAVINE ROAD, SUITE B FOLSOM, CA (916) (800) FAX (916) Page 2 of 16
245 LABORATORY NARRATIVE EPA TO-15 Groundwater & Environmental Services, Inc. (GES) Workorder# Two 6 Liter Summa Canister samples were received on January 27, The laboratory performed analysis via EPA TO-15 using GC/MS in the full scan mode. This workorder was independently validated prior to submittal using 'USEPA National Functional Guidelines' as generally applied to the analysis of volatile organic compounds in air. A rules-based, logic driven, independent validation engine was employed to assess completeness, evaluate pass/fail of relevant project quality control requirements and verification of all quantified amounts. Receiving Notes There were no receiving discrepancies. Analytical Notes There were no analytical discrepancies. Definition of Data Qualifying Flags Eight qualifiers may have been used on the data analysis sheets and indicates as follows: B - present in laboratory blank greater than reporting limit (background subtraction not performed). J - Estimated value. E - Exceeds instrument calibration range. S - Saturated peak. Q - Exceeds quality control limits. U - analyzed for but not detected above the reporting limit, LOD, or MDL value. See data page for project specific U-flag definition. UJ- Non-detected compound associated with low bias in the CCV N - The identification is based on presumptive evidence. File extensions may have been used on the data analysis sheets and indicates as follows: a-file was requantified b-file was quantified by a second column and detector r1-file was requantified for the purpose of reissue Page 3 of 16
246 Summary of Detected s Client Sample ID: Till Lab ID#: A cis-1,2-dichloroethene 1,1,1-Trichloroethane Trichloroethene 1,1,2-Trichloroethane Tetrachloroethene Client Sample ID: Alluvium Lab ID#: A Freon 12 Hexane cis-1,2-dichloroethene 1,1,1-Trichloroethane Trichloroethene 1,1,2-Trichloroethane Tetrachloroethene Page 4 of 16
247 File Name: a Dil. Factor: 1.56 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Till Lab ID#: A Date of Collection: 1/24/17 10:00:00 AM Date of Analysis: 2/2/17 10:48 PM 0.78 Not Detected 3.8 Not Detected 0.78 Not Detected 5.4 Not Detected 7.8 Not Detected 16 Not Detected 0.78 Not Detected 2.0 Not Detected 0.78 Not Detected 1.7 Not Detected 7.8 Not Detected 30 Not Detected 3.1 Not Detected 8.2 Not Detected 0.78 Not Detected 4.4 Not Detected 3.1 Not Detected 5.9 Not Detected 0.78 Not Detected 6.0 Not Detected 0.78 Not Detected 3.1 Not Detected 7.8 Not Detected 18 Not Detected 3.1 Not Detected 7.7 Not Detected 3.1 Not Detected 9.7 Not Detected 3.1 Not Detected 9.8 Not Detected 7.8 Not Detected 27 Not Detected 3.1 Not Detected 11 Not Detected 0.78 Not Detected 3.1 Not Detected 0.78 Not Detected 2.7 Not Detected 0.78 Not Detected 3.2 Not Detected 3.1 Not Detected 9.2 Not Detected Not Detected 2.3 Not Detected 0.78 Not Detected 3.8 Not Detected Not Detected 2.7 Not Detected 0.78 Not Detected 4.9 Not Detected 0.78 Not Detected 3.6 Not Detected 0.78 Not Detected 2.5 Not Detected 0.78 Not Detected 3.2 Not Detected 0.78 Not Detected 3.2 Not Detected Not Detected 3.6 Not Detected 3.1 Not Detected 11 Not Detected 0.78 Not Detected 5.2 Not Detected 0.78 Not Detected 3.5 Not Detected 0.78 Not Detected 3.2 Not Detected 0.78 Not Detected 2.9 Not Detected 0.78 Not Detected 3.5 Not Detected Not Detected 13 Not Detected Page 5 of 16
248 File Name: a Dil. Factor: 1.56 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Till Lab ID#: A Date of Collection: 1/24/17 10:00:00 AM Date of Analysis: 2/2/17 10:48 PM 0.78 Not Detected 6.6 Not Detected 0.78 Not Detected 6.0 Not Detected 0.78 Not Detected 3.6 Not Detected 0.78 Not Detected 3.4 Not Detected 0.78 Not Detected 3.4 Not Detected 0.78 Not Detected 3.4 Not Detected 0.78 Not Detected 3.3 Not Detected 0.78 Not Detected 8.1 Not Detected 0.78 Not Detected 3.8 Not Detected 0.78 Not Detected 5.4 Not Detected 0.78 Not Detected 3.8 Not Detected 0.78 Not Detected 3.8 Not Detected 0.78 Not Detected 3.8 Not Detected 0.78 Not Detected 3.8 Not Detected 0.78 Not Detected 4.7 Not Detected 0.78 Not Detected 4.7 Not Detected 0.78 Not Detected 4.0 Not Detected 0.78 Not Detected 4.7 Not Detected 3.1 Not Detected 23 Not Detected 3.1 Not Detected 33 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 6 of 16
249 File Name: a Dil. Factor: 1.60 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Alluvium Lab ID#: A Date of Collection: 1/24/17 10:15:00 AM Date of Analysis: 2/2/17 11:15 PM Not Detected 5.6 Not Detected 8.0 Not Detected 16 Not Detected 0.80 Not Detected 2.0 Not Detected 0.80 Not Detected 1.8 Not Detected 8.0 Not Detected 31 Not Detected 3.2 Not Detected 8.4 Not Detected 0.80 Not Detected 4.5 Not Detected 3.2 Not Detected 6.0 Not Detected 0.80 Not Detected 6.1 Not Detected 0.80 Not Detected 3.2 Not Detected 8.0 Not Detected 19 Not Detected 3.2 Not Detected 7.9 Not Detected 3.2 Not Detected 10 Not Detected 3.2 Not Detected 10 Not Detected 8.0 Not Detected 28 Not Detected 3.2 Not Detected 12 Not Detected 0.80 Not Detected 3.2 Not Detected Not Detected 3.2 Not Detected 3.2 Not Detected 9.4 Not Detected Not Detected 2.4 Not Detected 0.80 Not Detected 3.9 Not Detected Not Detected 2.8 Not Detected 0.80 Not Detected 5.0 Not Detected 0.80 Not Detected 3.7 Not Detected 0.80 Not Detected 2.6 Not Detected 0.80 Not Detected 3.2 Not Detected 0.80 Not Detected 3.3 Not Detected Not Detected 3.7 Not Detected 3.2 Not Detected 12 Not Detected 0.80 Not Detected 5.4 Not Detected 0.80 Not Detected 3.6 Not Detected 0.80 Not Detected 3.3 Not Detected 0.80 Not Detected 3.0 Not Detected 0.80 Not Detected 3.6 Not Detected Not Detected 13 Not Detected Page 7 of 16
250 File Name: a Dil. Factor: 1.60 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Alluvium Lab ID#: A Date of Collection: 1/24/17 10:15:00 AM Date of Analysis: 2/2/17 11:15 PM 0.80 Not Detected 6.8 Not Detected 0.80 Not Detected 6.1 Not Detected 0.80 Not Detected 3.7 Not Detected 0.80 Not Detected 3.5 Not Detected 0.80 Not Detected 3.5 Not Detected 0.80 Not Detected 3.5 Not Detected 0.80 Not Detected 3.4 Not Detected 0.80 Not Detected 8.3 Not Detected 0.80 Not Detected 3.9 Not Detected 0.80 Not Detected 5.5 Not Detected 0.80 Not Detected 3.9 Not Detected 0.80 Not Detected 3.9 Not Detected 0.80 Not Detected 3.9 Not Detected 0.80 Not Detected 3.9 Not Detected 0.80 Not Detected 4.8 Not Detected 0.80 Not Detected 4.8 Not Detected 0.80 Not Detected 4.1 Not Detected 0.80 Not Detected 4.8 Not Detected 3.2 Not Detected 24 Not Detected 3.2 Not Detected 34 Not Detected Container Type: 6 Liter Summa Canister Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 8 of 16
251 File Name: a Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 2/2/17 02:42 PM 0.50 Not Detected 2.5 Not Detected 0.50 Not Detected 3.5 Not Detected 5.0 Not Detected 10 Not Detected 0.50 Not Detected 1.3 Not Detected 0.50 Not Detected 1.1 Not Detected 5.0 Not Detected 19 Not Detected 2.0 Not Detected 5.3 Not Detected 0.50 Not Detected 2.8 Not Detected 2.0 Not Detected 3.8 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.0 Not Detected 5.0 Not Detected 12 Not Detected 2.0 Not Detected 4.9 Not Detected 2.0 Not Detected 6.2 Not Detected 2.0 Not Detected 6.3 Not Detected 5.0 Not Detected 17 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.8 Not Detected 0.50 Not Detected 2.0 Not Detected 2.0 Not Detected 5.9 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.5 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 1.7 Not Detected 0.50 Not Detected 3.1 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 1.6 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 2.3 Not Detected 2.0 Not Detected 7.2 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.0 Not Detected 0.50 Not Detected 1.9 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.7 Not Detected 0.50 Not Detected 3.4 Not Detected 2.0 Not Detected 8.2 Not Detected Page 9 of 16
252 File Name: a Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Client Sample ID: Lab Blank Lab ID#: A Date of Collection: NA Date of Analysis: 2/2/17 02:42 PM 0.50 Not Detected 4.2 Not Detected 0.50 Not Detected 3.8 Not Detected 0.50 Not Detected 2.3 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.2 Not Detected 0.50 Not Detected 2.1 Not Detected 0.50 Not Detected 5.2 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 2.4 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 3.0 Not Detected 0.50 Not Detected 2.6 Not Detected 0.50 Not Detected 3.0 Not Detected 2.0 Not Detected 15 Not Detected 2.0 Not Detected 21 Not Detected Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Page 10 of 16
253 Client Sample ID: CCV Lab ID#: A File Name: a Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 2/2/17 10:10 AM Page 11 of 16
254 Client Sample ID: CCV Lab ID#: A File Name: a Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 2/2/17 10:10 AM Page 12 of 16
255 Client Sample ID: LCS Lab ID#: A File Name: a Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 2/2/17 10:35 AM Page 13 of 16
256 Client Sample ID: LCS Lab ID#: A File Name: a Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 2/2/17 10:35 AM Page 14 of 16
257 Client Sample ID: LCSD Lab ID#: AA File Name: a Dil. Factor: 1.00 Freon 12 Freon 114 Chloromethane Vinyl Chloride 1,3-Butadiene Bromomethane Chloroethane Freon 11 Ethanol Freon 113 1,1-Dichloroethene Acetone 2-Propanol Carbon Disulfide 3-Chloropropene Methylene Chloride Methyl tert-butyl ether trans-1,2-dichloroethene Hexane 1,1-Dichloroethane 2-Butanone (Methyl Ethyl Ketone) cis-1,2-dichloroethene Tetrahydrofuran Chloroform 1,1,1-Trichloroethane Cyclohexane Carbon Tetrachloride 2,2,4-Trimethylpentane Benzene 1,2-Dichloroethane Heptane Trichloroethene 1,2-Dichloropropane 1,4-Dioxane Bromodichloromethane cis-1,3-dichloropropene 4-Methyl-2-pentanone Toluene trans-1,3-dichloropropene 1,1,2-Trichloroethane Tetrachloroethene 2-Hexanone Date of Collection: NA Date of Analysis: 2/2/17 11:00 AM Page 15 of 16
258 Client Sample ID: LCSD Lab ID#: AA File Name: a Dil. Factor: 1.00 Dibromochloromethane 1,2-Dibromoethane (EDB) Chlorobenzene Ethyl Benzene m,p-xylene o-xylene Styrene Bromoform Cumene 1,1,2,2-Tetrachloroethane Propylbenzene 4-Ethyltoluene 1,3,5-Trimethylbenzene 1,2,4-Trimethylbenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene alpha-chlorotoluene 1,2-Dichlorobenzene 1,2,4-Trichlorobenzene Hexachlorobutadiene Container Type: NA - Not Applicable Surrogates Toluene-d8 1,2-Dichloroethane-d4 4-Bromofluorobenzene Date of Collection: NA Date of Analysis: 2/2/17 11:00 AM Page 16 of 16
259
260
Memorandum. Introduction
5670 Greenwood Plaza Blvd Suite 540 Greenwood Village, Colorado 80111 PH 720.509.8901 www.geosyntec.com Memorandum Date: November 1, 2017 To: CC: From: Kelly Weidenbach, Natrona County Health Department
More informationSilicon-Lined Canister Cleaning Practices and Blank VOC Concentrations. Jason S. Herrington, Gary Stidsen, Trent Sprenkle, Steve Kozel
Silicon-Lined Canister Cleaning Practices and Blank VOC Concentrations Jason S. Herrington, Gary Stidsen, Trent Sprenkle, Steve Kozel U.S. EPA Method TO-15 A guidance document for a Performance Based Method
More informationTECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS
TECHNICAL NOTE s for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS The DataFID and MicroFID II are portable flame ionization detectors designed to monitor volatile organic
More informationSPECIAL SPECIFICATION 5159 Soil, Groundwater and Surface Water Management Plan
2004 Specifications CSJ 2964-01-030 SPECIAL SPECIFICATION 5159 Soil, Groundwater and Surface Water Management Plan 1. Description. Handle and manage Trichloroethylene impacted soil, groundwater and surface
More informationSUPPLEMENTAL LIMITED PHASE II INVESTIGATION PARCEL IDENTIFICATION NUMBER H WEST HURON RIVER DRIVE ANN ARBOR, WASHTENAW, MICHIGAN
SUPPLEMENTAL LIMITED PSE II INVESTIGATION PARCEL IDENTIFICATION NUMBER H-08-2-300-027 303 WEST HURON RIVER DRIVE ANN ARBOR, WASHTENAW, MICHIGAN MAY 28, 204 PREPARED FOR: THE CITY OF ANN ARBOR 30 EAST HURON
More informationProcess and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples
Process and Air Monitoring Online GC systems for continuous monitoring of organic compounds in air and gaseous samples For 35 years AMA Instruments has developed and manufactured analytical devices and
More informationExecutive Summary. 1. Introduction Background 2
Post-Class C RAO Status Report No. 2 Former Hersey Products, 250 Elm Street, Dedham, MA Tyco International Management Company June 24, 2009 Table of Contents Executive Summary ii 1. Introduction 1 2. Background
More informationAirSentry FTIR Multi-gas Open Path FTIR Analyzer
AirSentry FTIR Multi-gas Open Path FTIR Analyzer Multi-Component Gas Analysis... The Cerex AirSentry FTIR Multi-gas Open Path Analyzer: The standard for multi-gas open path monitoring. Regulatory Compliant
More informationShepherd FTIR. Laboratory Quality Results. Continuous, real time portable monitoring of 385 individual species of gas: 100+ HAPs. ...
Shepherd FTIR Portable FTIR Multi-gas Analyzer Laboratory Quality Results Acids VOCs, SVOCs Continuous, real time portable monitoring of 385 individual species of gas: 100+ HAPs. Fluorocarbons, CFCs Solvents
More informationFACT SHEET Program: Lab Fire Safety
REFRIGERATION/FREEZING OF FLAMMABLE LIQUIDS Fires and explosions can and do occur in either general-purpose laboratory or ordinary domestic refrigerators or freezers when these types of appliances are
More informationWATER QUALITY TESTING FOR SCHAUMBURG COMMUNITY CONSOLIDATED SCHOOL DISTRICT 54 HOOVER SCHAUMBURG, ILLINOIS OCTOBER 3, 2017 PROJECT NUMBER:
WATER QUALITY TESTING FOR SCHAUMBURG COMMUNITY CONSOLIDATED SCHOOL DISTRICT 54 HOOVER SCHAUMBURG, ILLINOIS OCTOBER 3, 2017 PROJECT NUMBER: 17-18350 1550 Hubbard Ave., Batavia, IL 60510, 630-879-3006 Schaumburg
More informationMW-401B Area Soil Remediation Report
MW-401B Area Soil Remediation Report Maine Yankee Decommissioning Project Corrective Measures Study December 2004 Prepared for: Maine Yankee 321 Old Ferry Road, Bailey Point Wiscasset, ME 04578 Prepared
More informationSiloxanes: Quantifying a New Emergent Pollutant in Water, Air and Soil
Siloxanes: Quantifying a New Emergent Pollutant in Water, Air and Soil Patrick Novak, B.Sc, P.Chem RemTech 2013 October 16, 2013 Outline Who is CARO? What are Siloxanes? Concerns Legislation Water Air
More informationDräger X-pid 9000 / 9500 Multi-Gas Detection
Dräger X-pid 9000 / 9500 Multi-Gas Detection The selective PID gas measurement device is ideal for users who frequently test for hazardous toxic substances Benzene, butadiene and other volatile organic
More informationMERIDIAN UNIVERSAL GAS DETECTOR
MERIDIAN UNIVERSAL GAS DETECTOR MERIDIAN UNIVERSAL GAS DETECTOR The term universal is frequently used in the industry to characterize gas detectors that address both toxic and combustible gases, but it
More informationMeridian. Universal Gas Detector. Description. Features. Minimal drift High specificity Digital ID Broader toxic gas detection
3M TM Meridian Description Designed with safety and reliability in mind, the Meridian universal gas detector is suitable for use in SIL-2 and SIL-3-rated systems under the IEC 61508 standards, certified
More informationElectron Microscopy Sciences
Electron Microscopy Sciences INSTRUCTIONAL MANUAL CAT. 72341-10 Explosion Proof Hot Plate Stirrer Model SF87325 P.O. Box 550 s1560 Industry Road s Hatfield PA 19440 1 Safety Symbols Used in this Instruction
More informationImagine the result. Dear Ms. Vanderlaan:
Mary Vanderlaan Supervisor, Lansing District Michigan Department of Environmental Quality Water Resources Division 525 W. Allegan (Constitution Hall, 4N) P. O. Box 30242 Lansing, MI 48909-7742 ARCADIS
More informationULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]
ULTIMA XIR ULTIMA X 3 ULTIMA XE ULTIMA X Series [ State-of-the-Art Gas Monitoring] ULTIMA X Gas Monitors [ Providing a unique Range of Capabilities] ULTIMA X are state-of-the-art gas monitors for continuous
More informationMolekule Produces No Ozone or Other Secondary Pollutants, and Actually Reduces Ozone in the Air.
Cover Sheet Molekule Produces No Ozone or Other Secondary Pollutants, and Actually Reduces Ozone in the Air. PURPOSE: Some earlier generation air purifiers, have been shown to release ozone or secondary
More informationCOVER SHEET EXECUTIVE SUMMARY
Regional Sewerage System Pretreatment Program Annual Report Fiscal Year 2013-2014 Table of Contents COVER SHEET EXECUTIVE SUMMARY SECTION 1 RESULTS OF POTW SAMPLING AND ANALYSIS 1 SECTION 2 SUMMARY OF
More informationWoodlin Elementary School Date of Report March 14, 2018
MCPS RADON TESTING - EXECUTIVE SUMMARY Site Name Woodlin Elementary School Date of Report March 14, 2018 Round of Testing Initial Follow-up Post Remediation 2 year testing 5 year testing HVAC Upgrade Window
More informationENVIRON INTERNATIONAL CORPORATION THE USE OF A GAS-IMAGING DEVICE FOR DETECTING FUGITIVE EMISSIONS IN ETHYLENE FACILITIES
ENVIRON INTERNATIONAL CORPORATION THE USE OF A GAS-IMAGING DEVICE FOR DETECTING FUGITIVE EMISSIONS IN ETHYLENE FACILITIES Presented at the Texas Technology Showcase March 2003 METHOD 21 CAN BE COSTLY AND
More informationExplosion-proof Duct Heaters
Safety INDEECO explosion-proof ULTRA-SAFE and EP2 duct heaters are Factory Mutual (FM) and CSA Approved. The ULTRA-SAFE duct heater has the only standard product offering and features the industry s lowest
More informationLFL Monitoring. MEGTEC Systems
LFL Monitoring MEGTEC Systems Flammability For each volatile flammable substance there is a concentration in air (usually expressed as % of volume, known as Lower Flammable Limit LFL). Below LFL concentration
More informationExplosion Proof Speaker, Ringer & Speaker/Ringer
Explosion Proof Speaker, Ringer & Speaker/Ringer Models SR40 and SR60 Installation & Operation P004562 Rev. G 150831 8/31/2015 11:06 AM Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com
More informationSP-220. Features. Combustible handheld gas leakage detector
SP-220 Combustible handheld gas leakage detector The SP-220 gas leakage detector is a simple to operate unit with high sensitivity to a variety of gases. The SC version (SP-220SC) is able to detect super-toxic,
More informationRelease Abatement Measure Status Report
Release Abatement Measure Status Report F.B. Rogers 414 West Water Street Taunton, Massachusetts September 15, 2011 Prepared for: Mr. Kevin Shea City of Taunton Office of Economic and Community Development
More informationESD3000 ESD200 Combustible / Toxic Gas Detector
ESD3000 ESD200 Combustible / Toxic Gas Detector Combustible and toxic gas leakage inspection instrument in industrial application Ex-proof certificate Exd ⅡC T6 Gb/Ex d ib ⅡC T6 Gb Dust Ex-proof certificate
More informationESD500. ESD500 Combustible / Toxic Gas Detector
ESD500 ESD500 Combustible / Toxic Gas Detector Combustible and toxic gas leakage inspection instrument in industrial application Ex-proof certificate Exd ⅡC T6 Gb/Ex d ib ⅡC T6 Gb Dust Ex-proof certificate
More informationThe Louis Berger Group, Inc. 15 January 2016
15 January 2016 THE Louis Berger Group, INC. 350 Eagleview Boulevard, Suite 250, Exton, Pennsylvania 19341-1178 Tel 610 280-4000 Fax 610 363-5390 www.louisberger.com Ms. Anne J. Wolf Facilities R&A Team
More informationWorking safely with flammable liquids
Flammable Liquids Fire hazards are associated with vapors from the flammable liquid. In order for a fire to occur, the following conditions must be met: Concentration of the vapor must be between the upper
More information2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)
CHAPTER 1 SCOPE AND ADMINISTRATION 102.7 Referenced codes and standards. The codes and standards referenced in this code shall be those that are listed in Chapter 45 47 and such codes and standards shall
More informationIntelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.
Features To measure and take control of indoor air quality Three noses in same unit Air Quality (VOC), Humidity (rh) and Temperature (T) Selectable outputs 0-10 Vdc, 4-20 ma or 0-5 Vdc via jumpers on pcb
More informationExplosion Proof Speaker, Ringer & Speaker/Ringer
Explosion Proof Speaker, Ringer & Speaker/Ringer Models SR40 and SR60 Installation & Operation P004562 Rev. H 180430 4/30/2018 12:24 PM Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com
More informationOperating manual ELECTRIC ASPIRATOR 00) : 1) Page 1
Operating manual ELECTRIC ASPIRATOR (Model : 75301-00 00) Manual No: 00HAA0001135 (Rev ( : 1) Page 1 Cole-Parmer Instrument Company (800)323-4340 Fax:(847)247-2929 Page 2 625 East Bunker Court, Vernon
More informationAdjustable Back Pressure Flow Controller Instructions
Adjustable Back Pressure Flow Controller Instructions Please Read The Following Important Information Before Starting Mechanical Gauges should be used only for approximate pressure/vacuum readings. The
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the GC 866 PID airtoxic (Model A73022) manufactured by: Chromatotec / airmotec 15, Rue d Artiguelongue Saint -Antoine 33240 Val de Virvée France has
More informationRADON SCREENING SURVEY FOLLOW-UP SPRINGBROOK HIGH SCHOOL
RADON SCREENING SURVEY OLLOW-UP SPRINGBROOK HIGH SCHOOL, Silver Spring, Maryland 20904 EXECUTIVE SUMMARY Date of Test Report: 9 ebruary 2016 Round of Testing: Initial ollow-up Post Remediation # rooms
More informationSENTRY-MS Mono-static Multi-gas Open Path Analyzer
SENTRY-MS Mono-static Multi-gas Open Path Analyzer Air Monitoring Where You Need it... The Cerex Sentry-MS Multi-gas Open Path Analyzer is specifically designed for rapid deployment for a variety of indoor
More informationWater Quality Report
As part of our ongoing commitment to responsible business, transparency, and service to our customers, EartH 2 O is happy to provide this detailed report on the quality of our water and processes. The
More informationMinisterial Decree No. 14/2005 (VI. 28.) KvVM. on the rules concerning the screening surveys of remedial site investigations.
Ministerial Decree No. 14/2005 (VI. 28.) KvVM on the rules concerning the screening surveys of remedial site investigations Authorised by the provisions set forth in clause m), Paragraph (8), Article 110
More informationPOTW PRETREATMENT ANNUAL REPORT COVERSHEET. July 1, 2017 to June 30, 2018
POTW PRETREATMENT ANNUAL REPORT COVERSHEET NPDES PERMIT HOLDER: REPORT PERIOD: INLAND EMPIRE UTILITIES AGENCY July 1, 2017 to June 30, 2018 NAME OF WASTEWATER TREATMENT PLANT(S) Regional Water Recycling
More informationLAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:
LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: ALPHA TRACK Method Number: ELAP method number 7035 SOP Number: Revision Number: SOP Date: Personnel / Data Records observed: Page 1 of 6 RADON IN AIR
More informationRADON SCREENING SURVEY FOLLOW-UP CONCORD CENTER Hidden Creek Rd, Bethesda, Maryland 20817
RADON SCREENING SURVEY FOLLOW-UP CONCORD CENTER 7210 Hidden Creek Rd, Bethesda, Maryland 20817 EXECUTIVE SUMMARY Date of Test Report: 3/31/16 Follow-Up Round of Testing: Initial Follow-up Post Remediation
More informationEMSL Analytical, Inc.
Phone: (856) 303-2500 Fax: (856) 858-4571 Email: 9/1/2016 The following analytical report covers the analysis performed on samples submitted to EMSL Analytical, Inc. on 8/31/2016. The results are tabulated
More informationThank You for Attending Today s Webinar:
Detect, Measure, Analyze. Thank You for Attending Today s Webinar: Best Practices in Maintaining Gas Detection Systems Featured Speaker John Greivell VP Operations RAECO-LIC LLC johng@raeco.com Featured
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the 3000HM Flame Ionisation Detector 3010 & 3030 Portable Flame Ionisation Detector manufactured by: Signal Group Ltd 12 Doman Road Camberley Surrey,
More informationMultnomah Education Service District
Cascade Radon, Inc. 12839 NE Airport Way Bldg.9 Testing, Mitigation, Portland, Oregon 97230 Systems Design Phone: (503) 421-4813 CCB 180537 / CASCARI927C1 Fax: (503) 281-6170 Office@CascadeRadon.com Radon
More informationManufacturers of Explosion Proof, Corrosion Resistant and Severe Duty HVAC/R Systems, and Pressurization Equipment.
Manufacturers of Explosion Proof, Corrosion Resistant and Severe Duty HVAC/R Systems, and Pressurization Equipment. COPYRIGHT 2011 Safe Air Technology LLC. All Rights Reserved Severe Duty Design for: Safe
More information2016 Annual Monitoring Report Site 23 (PICA-065) Post Farm Landfill. Picatinny Arsenal, New Jersey. Prepared for. Prepared by
2016 Annual Monitoring Report Site 23 (PICA-065) Post Farm Landfill Picatinny Arsenal, New Jersey Prepared for Prepared by EA Engineering, Science, and Technology, Inc., PBC Contract No. W91ZLK-13-D-0004-0009
More informationRADON SCREENING SURVEY FOLLOW-UP WHITTIER WOODS CENTER Whittier Boulevard, Bethesda, Maryland 20817
RADON SCREENING SURVEY FOLLOW-UP WHITTIER WOODS CENTER 7100 Whittier Boulevard, Bethesda, Maryland 20817 EXECUTIVE SUMMARY Date of Test Report: 5/12/16 Round of Testing: Initial Follow-up Post Remediation
More informationEarly Warning Solutions
Early Warning Solutions for Airborne Toxic Industrial Chemicals René Braun Research and Development Remote Sensing Rene.Braun@bruker.com Early Warning Solutions for Airborne Toxic Industrial Chemicals
More informationSubject: Notification of Petroleum Dry Cleaning Machine Installation (SUN - 175)
SWCAA Southwest Clean Air Agency 11815 NE 99th Street, Suite 1294 Vancouver, WA 98682 (360) 574-3058 www.swcleanair.org August 16, 2018 Eun Yi Imperial Cleaners Shop 470 NE Birch Street Camas, WA 98607-2029
More informationType SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate
Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate OPERATION MANUAL SERIES 873 UL Listed for Class I, Group C and D Hazardous Locations Model # Voltage Description SP87325 120 9.13 X 9.13 (23.2
More informationAPPLICATION DATA SHEET
APPLICATION DATA SHEET S p e c i f i c a t i o n WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700 D e t e c t o r C o n t r o l P a n e l Wall mounting 24V DC or 110/230vAC operation
More informationLow mg/m
1 (7) List 9.2.3 set Library name in Chempro100: CWA-9.2.3 Alarm indication Nerve Blister Library specified agents GA, GB, GD, GF VX HD L Low mg/m 3 0.1 0.1 2 2 Library unspecified agents/cases Nerve precursors
More information1.0 INTRODUCTION 2.0 CLASSIFICATION CRITERIA
1.0 INTRODUCTION This report presents the results of an investigation of the external fire resistance characteristics of the VELUX FCM Deck Mounted Skylight roof covering system in general accordance with
More informationType SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate
BARNSTEA THERMOLYNE CORPORATION Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate OPERATION MANUAL SERIES 873 UL Listed for Class I, Group C and Hazardous Locations Model # Voltage escription
More informationRADON SCREENING SURVEY FOLLOW-UP GREAT SENECA CREEK ELEMENTARY SCHOOL Dairymaid Drive, Germantown, Maryland 20874
RADON SCREENING SURVEY FOLLOW-UP GREAT SENECA CREEK ELEMENTARY SCHOOL 13010 Dairymaid Drive, Germantown, Maryland 20874 EXECUTIVE SUMMARY Date of Test Report: 3/31/16 Follow-Up Round of Testing: Initial
More informationRadon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For:
Radon Measurement Survey Report Site: 417 Fifth Street Aurora, Illinois 60505 Survey Dates: May 9, 2018 thru May 11, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois
More informationRadon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For:
Radon Measurement Survey Report Site: 240 Melrose Avenue Aurora, Illinois 60505 Survey Dates: May 1, 2018 thru May 3, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois
More informationQuality Assurance Plan for Conducting Radon Measurements
Quality Assurance Plan for Conducting Radon Measurements 921 Pheasant Run Lindsborg, Kansas 67456 (785) 510-0000 info@clarityinspect.com getyourinspection.com page 1 of 18 Table of Contents A.1 Approval
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the FIDAMAT 6 FID Analyser manufactured by: Siemens Production Automisation S.A.S. 1 Chemin de la Sandlach B.P. 189 F-67506 Haguenau Cedex France
More informationMonitoring for Toxic VOCs in Oil Industry Applications
30 June 2008 Organic chemicals consist of molecules that contain carbon. Volatile organic compounds (VOCs) are organic compounds characterized by their tendency to evaporate easily at room temperature.
More informationand storage tanks. CO and NOx detection from diesel engine emissions Hospitality Hotels and restaurants LPG detection in commercial kitchens
Scott Meridian Fixed Gas Detector This section introduces the Meridian Universal Fixed Gas Detector from Scott Safety, a Tyco International company and a world leader in the design and manufacture of industrial
More informationPARTS CLEANING AND DEGREASING
Important Note: The following text is excerpted directly from the New York State Department of Environmental Conservation s publication, Environmental Compliance, Pollution Prevention, and Self Assessment
More informationField Validation of an On-Line FTIR Analyzer for Measuring Total Siloxane Content in Landfill Gas
Field Validation of an On-Line FTIR Analyzer for Measuring Total Siloxane Content in Landfill Gas Barbara Marshik MKS Instruments Barbara_Marshik@MKSinst.com Presented at the 2014 LMOP Conference Distribuido
More informationFlammable and Combustible Liquids Checklist
Flammable and Combustible Liquids Checklist This checklist covers the storage and use of flammable or combustible liquids in drums or other containers not exceeding 60 gallons individual capacity. Dispensing
More informationA D D E N D U M N O. 1 To The Contract Documents Date: Project: Facilities Development & Planning Portable Building Relocation
LMA A D D E N D U M N O. 1 To The Contract Documents Date: 2-1-2018 Project: Facilities Development & Planning Portable Building Relocation Long Beach Unified School District Bid# FAC17-1718 The following
More informationPHOTOIONIZATION DETECTOR
P/N 1709-8773 REV 3.0 Printed 0104 1,000 Specifications Subject to Change PHOTOIONIZATION DETECTOR GUARANTEED. FOR LIFE. 1001 Oakdale Road, Oakdale, PA 15071-1500 (412) 788-4353 Toll Free 1-800-DETECTS
More informationPHOTOIONIZATION DETECTOR. Instruction Manual
PHOTOIONIZATION DETECTOR Instruction Manual OUR MISSION Design - Manufacture - Sell: Highest quality products for the preservation of life and property. Provide: Best customer service available. Dear
More informationROCKEFELLER UNIVERSITY
ROCKEFELLER UNIVERSITY NEW RIVER BUILDING AND FITNESS CENTER Draft Environmental Impact Statement CEQR No. : 14DCP019M Lead Agency: New York City Department of City Planning Prepared By: AKRF, Inc. November
More informationProcedures for Preparing and Receiving PUF Canisters and Filters
QSM Approval: Procedures for Preparing and Receiving PUF Canisters and 1. Introduction This Standard Operating Procedure provides instructions for preparing PUF canisters and filters for shipment to field
More informationTo receive important product updates, complete your product registration card online at register.labconco.com
User s Manual RapidVap Vacuum, N2 & N2/48 Evaporation Systems Models 7900000 7900001 7900002 7900003 7900010 7900011 7900012 7900013 7910000 7910001 7910010 7910011 7910012 7910013 7910014 7910015 To receive
More informationCHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting
LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting Method Number: ELAP method number 7036 SOP Number: Revision Number:
More informationGMA101. Operation Manual. Worldwide Supplier of Gas Detection Solutions
Worldwide Supplier of Gas Detection Solutions GfG Instrumentation, Inc. 119 Oak Valley Drive Ann Arbor, Mi. Phone: (7) 769-057 Fax: (7) 769-1888 E-Mail: info@gfg-inc.com Internet: www.gfg-inc.com GMA101
More informationSOLVENT CLEANING OPERATION EQUIPMENT SUMMARY FORM-44 Page 1 of 7
Page 1 of 7 (This form must be submitted for each equipment item) GENERAL 1. MANUFACTURER MODEL 2. SERIAL NUMBER DATE OF INSTALLATION (leave blank if not installed) 3. DEVICE TYPE (Check one) Batch-Load
More informationBiosolids Dewatering, Monitoring, and Disposal Programs
Water and Waste Department Environmental Standards Division Biosolids Dewatering, Monitoring, and Disposal Programs Environment Act Licence #1089E RR 2016 Water and Waste Department Service des eaux et
More informationRadon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For:
Radon Measurement Survey Report Site:July 5, 2018 1200 Front Street Aurora, Illinois 60505 Survey Dates: May 9, 2018 thru May 11, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora,
More informationRadon Detection Specialists, Inc.
Commercial Radon Survey Report Client: Community Consolidated School District 181 Site Address: Monroe School 210 N Madison Hinsdale, IL 60521 Survey Date: May 7, 2012 to May 9, 2012 Initial Test RDS-R-002
More informationVacuum and Compressor Systems for the Chemical Process Industry
Vacuum and Compressor Systems for the Chemical Process Industry Proven technology built from experience Gardner Denver Nash has been serving process industries such as petroleum, chemical and pharmaceutical
More informationRadon Measurement Survey Report. Rollins Elementary School 950 Kane Street Aurora, Illinois Prepared For:
Radon Measurement Survey Report Site: 950 Kane Street Aurora, Illinois 60505 Survey Dates: May 15, 2018 thru May 18, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois
More informationFormer Lockheed Martin French Road Facility Utica, New York Solvent Dock Area NYSDEC Site #
Former Lockheed Martin French Road Facility Utica, New York Solvent Dock Area NYSDEC Site #6-20080321-5 Third Quarter 2017 Corrective Action Progress Report Prepared for: Lockheed Martin Corporation 6801
More informationProject: Mooney Lake Preserve Received: Location: 300 Sixth Ave. N., Orono Complete: Noticed:
Permit Application No.: 15-445 Rules: Erosion Control, Wetland Protection, & Stormwater Management Applicant: BPS Properties, LLC Project: Mooney Lake Preserve Received: 8-24-15 Location: 300 Sixth Ave.
More informationWelcome. SRP Hot Topics Training. September 24, Tessie Fields
Welcome SRP Hot Topics Training September 24, 2015 Tessie Fields Office of Community Relations Site Remediation Program Tessie.fields2@dep.nj.gov (609) 292-9962 UPDATES TO IEC GUIDANCE September 24, 2015
More informationIndoor Air Quality Testing. Horry County Schools
! Report of: Indoor Air Quality Testing Horry y Schools Conway, SC Palme5o EHS Report No: 2019015 Submi5ed January 29, 2019 Prepared for: Horry y Schools Prepared By: Palme5o EHS, LLC. Suite F, Box 163
More informationVacuum Pump V-100 Operation Manual
Vacuum Pump V-100 Operation Manual 11593636E en Imprint Product Identification: Operation Manual (Original) Vacuum Pump V-100 11593636 Publication date: 06.2017 BÜCHI Labortechnik AG Meierseggstrasse 40
More informationPCD110X - Premium Choice with DC Motor (Ceiling Mounted Ventilation Fans)
PCD110X - Premium Choice with DC Motor Performance & Ventilating fan shall be S&P PCD110X mounted in the ceiling. The fan shall have a 6-year warranty. The fan shall be HVI Certified at 0.1 inch water
More informationMCPS RADON TESTING. Executive Summary: Festival Center. Date of Test Report: 4/15/2016 Round of Testing: Initial Follow-up Post Remediation
E NGINEERS P LANNERS S CIENTISTS C ONSTRUCTION M ANAGERS 936 RIDGEBROOK ROAD SPARKS, MD 21152 410-316-7800 (FAX) 410-316-7935 MCPS RADON TESTING Executive Summary: Festival Center Date of Test Report:
More informationGas detector tubes are most effective as a reference device for conducting spot checks, which gives an idea of present gas at that moment in time.
Whilst gas detector tubes are one of the most straight forward forms of gas detection, we often find ourselves answering your questions. So we thought that it would help if we published these questions
More informationFormer Truck Maintenance Garage Soil Remediation Report
Former Truck Maintenance Garage Soil Remediation Report Maine Yankee Decommissioning Project Corrective Measures Study February 2005 Prepared for: Maine Yankee 321 Old Ferry Road, Bailey Point Wiscasset,
More informationThe Electronic Newsletter of The Industrial Refrigeration Consortium Vol. 11 No. 1, 2011
chan The Electronic Newsletter of The Industrial Refrigeration Consortium Vol. 11 No. 1, 2011 PRESSURE RELIEF CAPACITY DETERMINATION FOR EQUIPMENT Previously in The Cold Front (2006), we provided an introduction
More informationMinnesota Local Road Research Board Local Operational Research Assistance Program (OPERA)
Minnesota Local Road Research Board Local Operational Research Assistance Program (OPERA) September 30, 2011 Storm Water Pollutant Removal in Rain Gardens OPERA Project Number: 2010-3 Project Sponsor:
More informationGMA 104 Operation Manual
GMA 104 Operation Manual Content Introduction 3 Application 3 For your Safety 3 Measuring Mode 4 Front View GMA 104 4 Function Description 4 Turning the System On 4 Detection Mode 4 Check of Display, Parameter
More informationCENTRIFAN PE. Evaporation the Easy, Environmental Way. Reliable Results for Small Samples. Small Volume Evaporator GREEN.
Evaporation the Easy, Environmental Way Reliable Results for Small Samples CENTRIFAN PE TM Small Volume Evaporator GREEN CHEMISTRY www.kdscientific.com CENTRIFAN PE Simplifies Small Volume Evaporation
More informationUNITIZED ULTRAVIOLET FIRE DETECTOR
MODEL #: UVU-140-A & UVU-140-AR UNITIZED ULTRAVIOLET FIRE DETECTOR REVISED: DECEMBER, 1999 REV. uvu140a-aroct99.wpd WARRANTY POLICY Net Safety Monitoring Inc. products are carefully designed and manufactured
More informationDepartment of State Health Services
Page I of 10 Pursuant to the Texas Radiation Control Act and Texas (Agency) regulations on radiation, and in reliance on statements and representations heretofore made by the licensee, a license is hereby
More informationRadon Detection Specialists, Inc.
Commercial Radon Survey Report Client: Community Consolidated School District 181 Site Address: Walker School 120 S Walker Clarendon Hills, IL 60514 Survey Date: April 25, 2012 to April 27, 2012 Initial
More informationFlammable and Combustible Liquids: Storage and Handling
Safety services Software Training Other articles Flammable and Combustible Liquids: Storage and Handling By W. Jon Wallace, CSP, MBA Flammable and combustible liquids are present in nearly every workplace.
More information