Rosemount 2120 Vibrating Fork Liquid Level Switch

Size: px
Start display at page:

Download "Rosemount 2120 Vibrating Fork Liquid Level Switch"

Transcription

1 Product Data Sheet Rosemount 2120 Rosemount 2120 Vibrating Fork Liquid Level Switch Function virtually unaffected by flow, bubbles, turbulence, foam, vibration, solids content, coating, properties of the liquid, and product variations No need for calibration and requires minimum installation procedures Easy terminal access, polarity insensitive and short circuit protection No moving parts or crevices means virtually no maintenance Electronic, self-checking, and condition monitoring - Heartbeat LED gives status and health information Adjustable Switching Delay for turbulent/splashing applications Magnetic test point makes functional test easy Small in size and weight Fast Drip Fork Design gives quicker response time especially with viscous liquids Explosion-proof/Flameproof and Intrinsically Safe options SIL 2 of IEC DIBt/WHG overfill protection Contents Reliable Performance...In Challenging Applications page 2 Rosemount 2120 Vibrating Fork Liquid Level Switch page 4 Specifications page 8 Product Certifications page 10 Dimensional Drawings page 12

2 Rosemount 2120 Product Data Sheet Reliable Performance...In Challenging Applications MEASUREMENT PRINCIPLE The Rosemount 2120 is designed using the principle of a tuning fork. A piezo-electric crystal oscillates the forks at their natural frequency. Changes to this frequency are continuously monitored. The frequency of the vibrating fork sensor changes depending on the medium in which it is immersed. The denser the liquid, the lower the frequency. When used as a low level alarm, the liquid in the tank or pipe drains down past the fork, causing a change of natural frequency that is detected by the electronics and switches the output state. When the 2120 is used as a high level alarm, the liquid rises in the tank or pipe, making contact with the fork which then causes the output state to switch. Threaded Process Connection Flanged Process Connection Adjustable Switching Delay KEY FEATURES AND BENEFITS Virtually unaffected by turbulence, foam, vibration, solids content, coating, or liquid properties The 2120 is designed for operation in temperatures from 40 to 02 F ( 40 to 150 C) DIBt/WHG overfill protection certification Electronic self-checking and condition monitoring. The heartbeat LED gives status and health information on the 2120 Adjustable switching delay prevents false switching in turbulent or splashing applications Fast Drip fork design gives quicker response time, especially with viscous liquids Rapid wet-to-dry time for highly responsive switching Fork shape is optimized for hand polishing to meet hygienic requirements No moving parts or crevices for virtually no maintenance Fast Drip Forks 2

3 Product Data Sheet Rosemount 2120 Fit and Forget Once installed, the 2120 is ready to go. It needs no calibration and requires minimum installation The heartbeat LED gives an instant visual indication that the unit is operational Functional testing of the instrument and system is easy with a magnetic test point You can install, and forget it Superior Performance The 2120 is a popular choice for high and low level alarm and pump control duties for its simplicity, ease of use, and reliability Functionality is virtually unaffected by flow, turbulence, bubbles, foam, or vibration The Fast Drip design allows the liquid to be quickly drawn away from the fork tip, making the 2120 quicker and more responsive in high density or viscous liquid applications With a user-selectable time delay feature, the risk of false switching is minimized in turbulent or splashing applications APPLICATIONS Overfill protection High and low level alarms Pump control or limit detection Run dry or pump protection Hygienic applications High temperature applications Wireless applications High And Low Level Alarm High Temperature Applications Pump Control / Limit Detection Wireless Applications

4 Rosemount 2120 Product Data Sheet Rosemount 2120 Vibrating Fork Liquid Level Switch Rosemount 2120 capabilities include: Ideal for almost all liquid applications Wide choice of materials, process connections, and switching mechanisms configurable for your application Electronic, self-checking, and condition monitoring User-adjustable mode selection and time delay switch SIL2 suitable Additional Information Spares and Accessories: page 7 Specifications: page 8 Certifications: page Level Switches Dimensions: page 12 TABLE Ordering Information The offering represents the most common options. The starred options ( ) should be selected for best delivery. The Expanded offering is subject to additional delivery lead time. Model Product Description 2120 Vibrating Fork Liquid Level Switch / F ( C) Materials of Construction: Process Connection/Fork D 16/16L Stainless Steel (1.4401/1.4404) dual certified N (1)(2) 16/16L SST (1.4401/1.4404) with NACE compliance to MR 0175:200 (ISO 15156:200), MR Expanded F () ECTFE/PFA copolymer, coated 16/16L SST (1.4401/1.4404) C (4) Alloy C (UNS N10002), Alloy C-276 (UNS N10276), Solid Process Connection Size / Type 0A /4-in. BSPT (R) Thread 0B /4-in. BSPP (G) Thread 0D /4-in. NPT Thread 1A 1-in. BSPT (R) Thread 1B 1-in. BSPP (G) Thread 1D 1-in. NPT Thread 1P 1-in. BSPP (G), O-ring, Hygienic Fitting 5R 1 1 /2-in. (8 mm) Tri-Clamp, Hygienic Fitting 2R 2-in. (51 mm) Tri-Clamp, Hygienic Fitting 5G 1 1 /2-in. ASME B16.5 Class 150 Raised Face (RF) Flange 5H 1 1 /2-in. ASME B16.5 Class 00 Raised Face (RF) Flange 2G 2-in. ASME B16.5 Class 150 Raised Face (RF) Flange 2H 2-in. ASME B16.5 Class 00 Raised Face (RF) Flange G -in. ASME B16.5 Class 150 Raised Face (RF) Flange H -in. ASME B16.5 Class 00 Raised Face (RF) Flange 4G 4-in. ASME B16.5 Class 150 Raised Face (RF) Flange 4H 4-in. ASME B16.5 Class 00 Raised Face (RF) Flange 5K DN40, EN1092 PN 10/16 Flange 5L DN40, EN1092 PN 25/40 Flange 2K DN50, EN1092 PN 10/16 Flange 2L DN50, EN1092 PN 25/40 Flange 7K DN65, EN1092 PN 10/16 Flange 4

5 Product Data Sheet Rosemount 2120 TABLE Ordering Information The offering represents the most common options. The starred options ( ) should be selected for best delivery. The Expanded offering is subject to additional delivery lead time. 7L DN65, EN1092 PN 25/40 Flange K DN80, EN1092 PN 10/16 Flange L DN80, EN1092 PN 25/40 Flange 4K DN100, EN1092 PN 10/16 Flange 4L DN100, EN1092 PN 25/40 Flange Expanded 5J 1 1 /2-in. ASME B16.5 Class 600 Raised Face (RF) Flange 2J 2-in. ASME B16.5 Class 600 Raised Face (RF) Flange J -in. ASME B16.5 Class 600 Raised Face (RF) Flange 4J 4-in. ASME B16.5 Class 600 Raised Face (RF) Flange 5M DN40, EN1092 PN 6 Flange 5N DN40, EN1092 PN 100 Flange 2M DN50, EN1092 PN 6 Flange 2N DN50, EN1092 PN 100 Flange 7M DN65, EN1092 PN 6 Flange 7N DN65, EN1092 PN 100 Flange M DN80, EN1092 PN 6 Flange N DN80, EN1092 PN 100 Flange 4M DN100, EN1092 PN 6 Flange 4N DN100, EN1092 PN 100 Flange XX (5) Customer Specific Electronic Type Available for Certifications S Direct load switching (2-wire) 20 to 264 Vac 50/60Hz, 20 to 60 Vdc NA, E1, E5, E6, E7, G5, G6 B PNP/PLC low voltage (-wire) 20 to 60 Vdc NA, E1, E5, E6, E7, G5, G6 R Relay (SPDT / SPCO) NA, E1, E5, E6, E7, G5, G6 C (6) IS NAMUR (Ex ia) I1, I, I5, I6, I7 Surface Finish Available for Connections 1 surface finish All 2 Hand polished (Ra < 0.4 µm) Hygienic Connection Only Product Certifications Available for Electronic Available for Housing NA No Hazardous Locations Certifications S, B, R A, D G5 (7) FM Ordinary Locations (unclassified, safe area) S, B, R Y, T G6 (8)(9) CSA Ordinary Locations (unclassified, safe area) S, B, R Y, T E1 ATEX Flameproof S, B, R X, S E5 (7) FM Explosion-proof S, B, R Y, T E6 (8) (9) CSA Explosion-proof S, B, R Y, T E7 IECEx Explosion-proof S, B, R X, S I1 ATEX Intrinsic Safety C A, D I NEPSI Intrinsic Safety C A, D I5 FM Intrinsic Safety C A, D I6 (9) CSA Intrinsically Safe C A, D I7 IECEx Intrinsic Safety C A, D Housing Available for Certifications A Glass Filled Nylon, M20 conduits/cable threads NA, I1, I, I5, I6, I7 D Glass Filled Nylon, 1 /2-in. NPT conduits/cable threads NA, I1, I, I5, I6, I7 X Aluminum Alloy, M20 conduits/cable threads E1, E7 Y Aluminum Alloy, /4-in. NPT conduits/cable threads E5, E6, G5, G6 S Stainless Steel, M20 conduits/cable threads E1, E7 T Stainless Steel /4-in. NPT conduits/cable threads E5, E6, G5, G6 5

6 Rosemount 2120 Product Data Sheet TABLE Ordering Information The offering represents the most common options. The starred options ( ) should be selected for best delivery. The Expanded offering is subject to additional delivery lead time. Fork Length Available Connection A length 1.7-in. (44 mm) All except flanged models H (2) length flange 4.0-in. (102 mm) All flanged models B (2) Ext 5.9-in. (150 mm) All except Tri-clamp 5R & 2R C (2) Ext 11.8-in. (00 mm) All except Tri-clamp 5R & 2R D (2) Ext 19.7-in. (500 mm) All except Tri-clamp 5R & 2R L (10) Semi-ext.9-in. (98 mm) 1A, 1B, and 1D E (11) Extended, customer specified length in tenths of inches All except 1-in. BSPP O-ring 1P M (11) Extended, customer specified length in millimeters All except 1-in. BSPP O-ring 1P OPTIONS Specific Extended Fork Length XXXX (11) Specific customer specified length in tenths of inches, or millimeters (only if fork length E or M is selected) Calibration Data Certification Q4 Certificate of functional test Material Traceability Certification Q8 (1)(2) Material traceability certification per EN Special Procedures P1 (12) Hydrostatic testing with certificate Overfill U1 (1) WHG/DIBt Overfill Protection Tag Plates ST Tag plate SST engraved plate (maximum 16 digits) WT Tag plate laminated paper (maximum 40 digits) Typical Model Number: 2120 D 0A C 1 I1 A A Q8 ST (1) Only available for wetted parts. (2) Not available for hand polished wet side. () ECTFE/PFA copolymer coating is not available on threaded options. (4) Only available of BSPT and NPT threaded process connection code 0A, 0D, 1A, and 1D as standard, other upon request. (5) Other process connections available upon request. (6) Rosemount 2120 IS Namur Vibrating Fork Level Sensor models 2120***C*I** has demonstrated proven reliability. It is suitable for applications up to SIL 2 of IEC as a Type B Safety Related Subsystem when configured as a high level alarm in conjunction with a Namur Barrier. (7) See Product Certifications on page 10. E5 includes G5 requirements. G5 is for use in unclassified, safe area locations only. (8) See Product Certifications on page page 10. E6 includes G6 requirements. G6 is for use in unclassified, safe area locations only. (9) The requirements of CRN are met when a Rosemount 2120 CSA-approved vibrating fork level switch model is configured with 16/16L stainless steel (1.4401/1.4404) wetted parts and either NPT threaded or 2-in. to 8-in. ASME B16.5 flanged process connections. (10) Only available with stainless steel material of construction D and glass nylon housing A and D. (11) Minimum length available for /4-in. threaded connection is.8 in. (95 mm); for 1-in. threaded, it is.7 in. (94 mm); for flanged, it is.5 in. (89 mm); and for Tri-Clamp, it is 4.1 in. (105 mm). Maximum length is in. (000 mm), except for ECTFE/PFA copolymer coating and hand polished process where the maximum length is 9.4 in. (1000 mm). Examples: Code E1181 is inches. Code M000 is 000 millimeters. (12) Option limited to units with extended lengths up to 59.1-in. (1500 mm). Option is not available for ECTFE/PFA coating. (1) Option not available for Stainless Steel housing codes S and T. 6

7 Product Data Sheet Rosemount 2120 Spare Parts and Accessories TABLE 2. Spare Parts and Accessories The offering represents the most common options. The starred options ( ) should be selected for best delivery. The Expanded offering is subject to additional delivery lead time. Spares and Accessories Seal for 1-in. BSPP (G1A). Material: Non-asbestos BS751 grade X carbon fiber with rubber binder Seal for /4-in. BSPP (G/4A). Material: Non-asbestos BS751 grade X carbon fiber with rubber binder Hygienic adaptor boss 1-in. BSPP. Material: 16 Stainless fitting. FPM/FKM O-ring in. (51 mm) Tri-clamp kit (vessel fitting, clamp ring, and seal). Material: 16 SST, NBR Nitrile Telescopic test magnet (1) 1 1 /2-in. BSPP adjustable clamp gland for 1-in. extended lengths. Material: 16 Stainless steel, (Si) Silicone rubber seal (1) 1 1 /2-in. NPT adjustable clamp gland for 1-in. extended lengths. Material: 16 Stainless steel, (Si) Silicone rubber seal (2) Replacement Cassette: Direct load switching (2 Wire) (Red) (2) Replacement Cassette: PNP/PLC cassette (Yellow) (2)() Replacement Cassette: Intrinsically Safe cassette (Blue) (2) Replacement Cassette: Relay output cassette (Green) (4) Replacement Cassette: FM Direct load switching (2 Wire) (Red) (4) Replacement Cassette: FM PNP/PLC cassette (Yellow) (4) Replacement Cassette: FM Relay output cassette (Green) (1) The adjustable clamp gland is not explosion-proof. (2) Available for Housing codes A and D. () I.S. cassettes can only be replaced with I.S. cassettes. Non-I.S. cassette types can be interchanged with other non-i.s. cassettes, but the new label must be fitted and the original part number transferred to the new label. (4) Available for Housing codes X, Y, S, and T. 7

8 Rosemount 2120 Product Data Sheet Specifications Physical Product Rosemount 2120 Vibrating Fork Liquid Level Switch Measuring principle Vibrating Fork Applications Most liquids including coating liquids, aerated liquids, and slurries Mechanical Housing and Enclosure Housing Code A D X Y S T Housing Material Housing Paint Nylon PA66 0%GF Not Applicable Connections See Process Connection Size / Type on page 4 Extended Lengths The maximum extended length is in. (000 mm) except for a hand-polished 2120 that is limited to 9.4 in. (1000 mm) Process Material 16/16L Stainless Steel (1.4401/ dual certified), Alloy C (UNS N10002) and Alloy C-276 (UNS N10276), or ECTFE/PFA co-polymer coated 16/16L Stainless Steel (1.4401/ dual certified) Hand polished to better than 0.4 m option available for hygienic connections Gasket material for /4-in. and 1-in. BSPP (G) is Non-asbestos BS751 Grade X carbon fiber with rubber binder Dimensional Drawings See Dimensional Drawings on page 12 Al alloy ASTM B26 56-T6 or LM25 TF Polyurethane Powder Coat 16C12 Stainless Steel Not Applicable LED Window PMMA None None Conduit Entry M20 1 /2-in. NPT M20 /4-in. NPT M20 /4-in. NPT Ingress Protection IP66/67 to EN60529 IP66/67 to EN60529, Type 4X IP66/67 to EN60529, Type 4X Performance Hysteresis (water) ±0.09-in. (±1 mm) nominal Switching Point (water) 0.5 in. (1 mm) from tip (vertical) / from edge (horizontal) of fork (this will vary with different liquid densities) Functional Maximum Operating Pressure The final rating depends on the selected process connection. Threaded Connection See Figure 1 for operating pressures. NOTE: Clamp glands and (page 7) limit the maximum pressure to psig (1, bar g) Hygienic Connection 45 psig (0 bar g) Flanged Connection See Figure 1 or Table (whichever one is the lowest) Process Pressure psig (barg) FIGURE 1. Process Pressure 1450 (100) 1160 (80) 2 (0) (-1.0) -40 (-40) 2 (0) 122 (50) 02 (150) Process Temperature F ( C) TABLE. Maximum Flange Pressure Rating Class/Rating SST Flanges ASME B16.5 Class psig (1) ASME B16.5 Class psig (1) ASME B16.5 Class psig (1) EN PN 10/16 10/16 barg (2) EN PN 25/40 25/40 barg (2) EN PN 6 6 barg (2) EN PN barg (2) (1) At 100 F (8 C), the rating decreases with an increasing process temperature. (2) At 122 F (50 C), the rating decreases with an increasing process temperature. 8

9 Product Data Sheet Rosemount 2120 Minimum and Maximum Operating Temperature See Figure 2 for operating temperatures. NOTE: Clamp glands and (page 7) limit the maximum temperature to 257 F (125 C). Ambient Temperature F ( C) Liquid Density Range Minimum 7.5 lb/ft (600 kg/m ) Liquid Viscosity Range 0.2 to cp (centipose) FIGURE 2. Temperature Solids Content and Coating Maximum recommended diameter of solid particles in the liquid is 0.2 in. (5 mm) For coating product, avoid bridging of forks Switching Delay User selectable 0., 1,, 10, 0 seconds delay for dry-to-wet and wet-to-dry switching CIP (Clean In Place) Cleaning Withstands steam cleaning routines up to 02 F (150 C) Electrical 176 (80) 122 (50) 2 (0) -40 (-40) -40 (-40) 2 (0) 140 (60) 02 (150) Process Temperature F ( C) Switching Mode User selectable switching mode (Dry=on or Wet=on) Protection Polarity insensitive. Over-current, short-circuit and load-missing protection. Surge protection to IEC6126. Terminal Connection (wire diameter) Max. 0.1 in 2 (2,5 mm 2 ). Note national regulations. Conduit Plugs/Cable Gland Metal Ex d Housing: Conduit entries for explosion-proof areas are shipped with two brass conduit plugs Plastic housing with direct load, PNP/PLC and IS electronics are shipped with one PA66 (1) cable gland and one blanking plug Plastic housing with relay electronics are shipped with two PA66 (1) cable glands Grounding The 2120 should always be grounded either through the terminals or using the external ground connection provided. Electrical Connections Direct load switching (two-wire) LOAD LINE 1 2 PE (Ground) Neutral 0V R I L Fuse 2A(T) Live +V DPST OPERATION MODE Dry On Mode Dry On Wet On Dry Wet Dry Wet Wet On Mode Seconds Delay Direct Load Switching WARNING Isolate Supply Before Removing Solid state PNP output for direct interface to PLC s (three wire) PE (Ground) + OUT Fuse 2A(T) 4 +V O/P 0V SPCO single relay for voltage free contacts 1 2 PE (Ground) N N 0V 10 0 Intrinsically Safe (IS) NAMUR to DIN 1924, IEC L Fuse 0.5A (T) Live +V DPST 10 0 R = External load (must be fitted ) U = V ~ (ac) (50/60Hz) IOFF < ma IL = mA î = 5A, 40ms U = 20-60V (dc) IOFF < ma IL = ma î = 5A, 40ms OPERATION MODE Dry On Mode Dry On Wet On Dry Wet Dry Wet Wet On Mode Seconds Delay U = 20-60V (dc) I < 4mA + I L IL (MAX) = 0-500mA î = 5A, 40ms UOUT(ON) = U - 2.5V IL (OFF) < 100µA OPERATION MODE Dry On Mode Dry On Wet On Dry Wet Wet Dry Wet On Mode 10 0 U = V ~ (ac) (50/60Hz) I < 6mA U = 20-60V I < 6mA (dc) 10 0 Seconds Delay OPERATION MODE Dry On Mode Dry On Wet On Dry Wet Dry Wet 0 0 Wet On Mode Seconds Delay I ON = I OFF = PLC/PNP Isolate Supply Before Removing RELAY NC C NO NC C NO U MAX = 250V ~ (ac) I MAX = 5A P MAX' = 1250VA, resistive P MAX' = 1000VA, inductive U MAX = 60V (dc) I MAX = 5A, U < 0V I MAX = 1.5A, U < 60V Intrinsically Safe + - Isolating amplifier to NAMUR (IEC , EN50227) must be used to meet I.S. requirements (1) Cable diameter 0.2 to 0. in. (5 to 8 mm) 9

10 Rosemount 2120 Product Data Sheet Product Certifications ORDINARY LOCATION CERTIFICATION FOR FM G5 Project ID: The switch has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). ORDINARY LOCATION CERTIFICATION FOR CSA G6 Certificate Number: 06 CSA The switch has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by CSA, a nationally recognized testing laboratory as accredited by the s Council of Canada (SCC). EUROPEAN DIRECTIVE INFORMATION The EC declaration of conformity for all applicable European directives for this product can be found on the Rosemount website at A hard copy may be obtained by contacting your local sales office. ATEX Directive (94/9/EC) Complies with the ATEX Directive. Pressure Equipment Directive (PED) (97/2/EC) The Rosemount 2120 is outside the scope of PED Directive. L.V. Directive EN Pollution degree 2, Category II (264V max), Pollution degree 2, Category III (150V max) Electro Magnetic Compatibility (EMC) Directive EN6126 Emissions to Class B. Immunity to industrial location requirements. Vibration Resistance EN60721 level M6/4M6 CE-mark Complies with applicable directives (EMC, ATEX, and LVD) Overfill Protection If required, select Product Certificates code U1 for WHG/DIBt overfill protection. The approval number is Z SIL Declaration of Conformity The Rosemount 2120 IS Namur Vibrating Fork Level Sensor (2120***C*I**) has demonstrated proven reliability. It is manufactured and supported in a manner suitable for applications up to SIL 2 of IEC as a Type B Safety Related Subsystem when configured (1) as a high level alarm in conjunction with a Namur Barrier. HAZARDOUS LOCATIONS CERTIFICATIONS North American Approvals Factory Mutual (FM) Explosion-proof Approval E5 Project ID: Explosion-proof for Class I, Div. 1, Groups A, B, C, and D Temperature Class: T6 (T amb 40 to 75 C) Enclosure: Type 4X Factory Mutual (FM) Intrinsically Safe Approval I5 Project ID: Intrinsically Safe for Class I, Div. 1, Groups A, B, C, and D Class I, Zone 0, AEx ia IIC Temperature Code: T5 (T amb 40 to 80 C, Tproc < 80 C) Control Drawing: 71097/1154 Ui=15 V, Ii=2 ma, Pi=0.1 W, Ci=211 nf, Li=0.06 mh NOTE A NAMUR isolating amplifier must be used for intrinsic safety. Canadian Approvals Canadian s Association (CSA) Explosion-proof Approvals E6 Project ID: Explosion-proof for Class I, Div. 1, Groups A, B, C, and D Temperature Class: T6 (T amb 40 to 75 C) Enclosure: Type 4X Canadian s Association (CSA) Intrinsically Safe Approval I6 Certificate Number: 06 CSA Intrinsically Safe for Class I, Div. 1, Groups A, B, C, and D Class 1, Zone 0, Ex ia IIC Temperature Code: T5 (T amb 40 to 80 C, Tproc < 80 C) Control Drawing: 71097/1179 Ui=15 V, Ii=2 ma, Pi=0.1 W, Ci=211 nf, Li=0.06 mh (1) Refer to manual for IEC configuration details. 10

11 Product Data Sheet Rosemount 2120 Canadian s Association (CSA) Non-Incendive Approval I6 Certificate Number: 06 CSA Non-Incendive for Class I, Div. 2, Groups A, B, C, and D Temperature Code: T5 (T amb 40 to 80 C, Tproc < 80 C) Control Drawing: 71097/1187 Ui=15 V, Ii=2 ma, Pi=0.1 W, Ci=211 nf, Li=0.06 mh NOTE A NAMUR isolating amplifier must be used for intrinsic safety. Canadian Registration Number (CRN) CRN 0F C NOTE The requirements of CRN are met when a Rosemount 2120 CSA-approved vibrating fork level switch model is configured with 16/16L stainless steel (1.4401/1.4404) wetted parts and either NPT threaded or 2-in. to 8-in. ASME B16.5 flanged process connections. European Approvals ATEX Flameproof Approval E1 Certificate: Sira 05ATEX1129X Flameproof and Dust: ATEX Marking II 1/2 G D Ex d IIC T6 to T2 Ex td A21 (T85 C to 265 C) IP6X ATEX Intrinsically Safe Approval I1 Certificate: Sira 05ATEX210X Intrinsic Safety and Dust: ATEX Marking II 1 G D Ex ia IIC T5 to T2 Ex iad 20 (T85 C to 265 C) IP6X Ui=15 V, Ii=2 ma, Pi=0.1 W, Ci=12 nf, Li=0.06 mh International Approvals National Supervision and Inspection Centre for Explosion Protection and Safety Instrumentation (NEPSI) Intrinsically Safe Approval I Certificates: GYJ0650 (when manufactured in Slough, UK) GYJ0651 (when manufactured in Singapore, Singapore) Intrinsic Safety: Ex ia IIC T5 (T amb 40 to 60 C) Ui=15 V, Ii=2 ma, Pi=0.1 W, Ci=12 nf, Li=0.06 mh NOTE A NAMUR isolating amplifier must be used for intrinsic safety. International Electrotechnical Commission (IEC) Flameproof Approval E7 Certificate: IECEx SIR X Flameproof and Dust: Zone 0/1 Ex d IIC T6 to T2 Ex td A21 (T85 C to 265 C) IP6X International Electrotechnical Commission (IEC) Intrinsically Safe Approval I7 Certificate: IECEx SIR X Intrinsically Safe and Dust: Ex ia IIC T5 to T2 Ex iad 20 (T85 C to 265 C) IP6X Ui=15 V, Ii=2 ma, Pi=0.1 W, Ci=12 nf, Li=0.06 mh NOTE A NAMUR isolating amplifier must be used for intrinsic safety. NOTE A NAMUR isolating amplifier must be used for intrinsic safety. 11

12 Rosemount 2120 Product Data Sheet Dimensional Drawings Threaded Mounting Glass Filled Nylon B C Glass Filled Nylon B C Cable entry M20x1.5 or /4-in. NPT Aluminum/SST B C 5.60 (142) E (M) (If Horizontal) Cable Gland (40) A/F Hexagon /4-in. or 1-in. Thread 0.9 (2) for /4-in. Thread 1.14 (29) for 1-in. Thread D (If Vertical) /4-in. or 1-in. Thread 2.72 (69) 1.7 (44) (If Horizontal) Cable Entry M20x1.5 or 1 /2-in. NPT (40) A/F Hexagon 0.9 (2) for /4-in. Thread 1.14 (29) for 1-in. Thread (If Vertical) D 2.72 (69) /4-in or 1-in. Thread 1.7 (44) (If Horizontal) (If Vertical) 0.9 (2) for /4-in. Thread 1.14 (29) for 1-in. Thread Note: Dimensions are in inches (millimeters) Thread Length Model Code A Minimum Length Model Code E (M) Maximum Length Model Code E (M) /4 in. 1.7 (44).74 (95) (000) 1 in. 1.7 (44).70 (94) (000) Material B C D Glass Nylon.52 (90) 4.02 (102) 4.72 (120) Aluminum 2.68 (68) 4.02 (102) 6.14 (156) Stainless Steel 2.76 (70) 4.1 (105) 6.0 (160) 12

13 Product Data Sheet Rosemount 2120 Flange Mounting (Glass filled nylon housing shown) B C D Cable Gland E (M) (If Horizontal) 1.14 (29) (If Vertical) Note: Dimensions are in inches (millimeters) Material Length Model Code H Minimum Length Model Code E (M) Maximum Length Model Code E (M) Stainless Steel 4 (102).50 (89) (000) ECTFE/PFA co-polymer coated 4 (102).50 (89) 9.7 (1000) Material B C D (1) Glass Nylon.52 (90) 4.02 (102) 6.0 (160) Aluminum 2.68 (68) 4.02 (102) 6.14 (156) Stainless Steel 2.76 (70) 4.1 (105) 7.87 (200) (1) Varies with flange rating and thickness. D is the nominal maximum thickness and allows a flange up to 1.77 in. (45 mm) thick. This equates to a 4-in. ASME B16.5 Class 600 Raised Face flange. 1

14 Rosemount 2120 Product Data Sheet Hygienic Fitting (Glass filled nylon housing shown) B C B B C C D E (M) Cable Gland 1 1 /2-in. or 2-in. Tri-Clamp D 2.52 (64) 1.7 (44) Cable Gland 1 1 /2-in. or 2-in. Tri-Clamp 0.9 (2) (If Vertical) 1-in. BSPP O-ring Seal D.07 (78) (If Horizontal) 0.9 (2) Cable Gland (40) A/F Hexagon (If Vertical) (If Horizontal) 1.14 (29) (If Vertical) Note: Dimensions are in inches (millimeters) Connection Length Model Code A Minimum Length Model Code E (M) Maximum Length Model Code E (M) Tri-Clamp 1.7 (44) 4.1 (105) (000) O-ring Seal (1-in. BSPP) 1.7 (44) Not Applicable Not Applicable Material B C D Glass Nylon.52 (90) 4.02 (102) 4.96 (126) Aluminum 2.68 (68) 4.02 (102) 6.14 (156) Stainless Steel 2.76 (70) 4.1 (105) 6.54 (166) 14

15 Product Data Sheet Rosemount

16 Rosemount 2120 Product Data Sheet Rosemount Level Solutions Emerson provides a complete range of Rosemount products for level measurement applications. Vibrating Fork Switches Point Level Detection For high and low alarms, overfill protection, pump control, including wide pressure and temperature requirements, and hygienic applications. Flexible mounting. Immune to changing process conditions and suitable for most liquids. The product line consists of: Rosemount 2160 Wireless Rosemount 210 Enhanced Rosemount 2120 Full-featured Rosemount 2110 Compact Differential Pressure Level or Interface Measurement Flexible mounting for liquid tank levels, including those with wide temperature and pressure requirements. Can be isolated by valves. Unaffected by: vapor space changes, surface conditions, foam, corrosive fluids, internal tank equipment. Optimize performance with direct mount, Tuned-System Assemblies: Rosemount DP Level Transmitters and Remote Seals Rosemount 051S_L, 051L, and 2051L Liquid Level Transmitters Ultrasonic Level Measurement Top mounted, non-contacting for simple tank and open air level measurements. Unaffected by fluid properties such as: density, viscosity, dirty coating, and corrosiveness. Appropriate for routine applications outside of explosion proof areas. The product line consists of: Rosemount 100 Series Ultrasonic Process Level Transmitters Guided Wave Radar Level and Interface Measurement Top mounted, direct level and interface measurement of liquids or solids, including those with wide temperature and pressure requirements. Unaffected by changing process conditions. Good fit for small spaces and easy swap for older technologies. The product line consists of: Rosemount 500 Series Accurate, superior performance transmitter in most applications including process vessels and control Rosemount 00 Series Versatile and easy-to-use transmitter in most liquid storage and monitoring applications Non-contacting Radar Level Measurement Top mounted, direct level measurement for liquids or solids, including those with wide temperature and pressure requirements. Can be isolated by valves. Unaffected by changing process conditions. Good for dirty, coating, and corrosive applications. The product line consists of: Rosemount 5400 Series Accurate, superior performance 2-wire transmitters for most liquid level applications and process conditions Rosemount 5600 Series 4-wire transmitters with maximum sensitivity and performance for solids, challenging reactors, rapid level changes, and excessive process conditions Chambers for Process Level Instrumentation Rosemount 9901 High quality chambers for external mounting of level measurement and control instrumentation on process vessels The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. All other marks are the property of their respective owners. Terms and Conditions of Sale can be found at Rosemount, Inc. All rights reserved. Emerson Process Management Rosemount Measurement 8200 Market Boulevard Chanhassen, MN 5517 USA Tel (USA) Tel (International) Fax Emerson Process Management Blegistrasse 2 P.O. Box 1046 CH 641 Baar Switzerland Tel +41 (0) Fax +41 (0) Emerson FZE P.O. Box 170 Jebel Ali Free Zone Dubai UAE Tel Fax Emerson Process Management Asia Pacific Pte Ltd 1 Pandan Crescent Singapore Tel Fax Service Support Hotline: Enquiries@AP.EmersonProcess.com Rev FA 11/10

Rosemount 2120 Vibrating Fork Liquid Level Switch

Rosemount 2120 Vibrating Fork Liquid Level Switch Rosemount 2120 Rosemount 2120 Vibrating Fork Liquid Level Switch Function virtually unaffected by flow, bubbles, turbulence, foam, vibration, solids content, coating, properties of the liquid, and product

More information

Rosemount 2120 Vibrating Fork Liquid Level Switch

Rosemount 2120 Vibrating Fork Liquid Level Switch Rosemount 2120 Rosemount 2120 Vibrating Fork Liquid Level Switch 2120 FEATURES: Function virtually unaffected by flow, turbulence, bubbles, foam, vibration, solids content, coating, properties of the liquid,

More information

Rosemount 3100 Series Ultrasonic Level Transmitters

Rosemount 3100 Series Ultrasonic Level Transmitters Product Data Sheet Ultrasonic Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for on-site programming Continuous measurement of level or distance-to-surface.

More information

Rosemount 2100 Series

Rosemount 2100 Series Rosemount 2100 Series Vibrating Fork Liquid Level Switches Level switches for demanding applications Reliable performance... Rosemount 2100 series vibrating fork level switches are suitable for virtually

More information

Rosemount 3100 Series Ultrasonic Level Transmitters

Rosemount 3100 Series Ultrasonic Level Transmitters Product Data Sheet Ultrasonic Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for on-site programming Continuous measurement of level or distance-to-surface.

More information

Rosemount 2130 Level Switch

Rosemount 2130 Level Switch Rosemount 2130 Level Switch Vibrating Fork Product Data Sheet March 2017 00813-0100-4130, Rev EE Designed for operation in process temperatures of 94 to 500 F ( 70 to 260 C) Electronic self-checking and

More information

Rosemount Full-featured Vibrating Fork Liquid Level Switch. Product Data Sheet February , Rev GE

Rosemount Full-featured Vibrating Fork Liquid Level Switch. Product Data Sheet February , Rev GE Product Data Sheet February 2015 00813-00-4030, Rev GE Rosemount 2120 Full-featured Vibrating Fork Liquid Level Switch Designed for operation in process temperatures of 40 to 302 F ( 40 to 150 ) Electronic

More information

Rosemount Full-featured Vibrating Fork Liquid Level Switch. Product Data Sheet July , Rev GD

Rosemount Full-featured Vibrating Fork Liquid Level Switch. Product Data Sheet July , Rev GD Product Data Sheet July 2014 00813-0100-4030, Rev GD Rosemount 2120 Full-featured Vibrating Fork Liquid Level Switch Designed for operation in process temperatures of 40 to 302 F ( 40 to 150 ) Electronic

More information

Rosemount 3490 Series

Rosemount 3490 Series Product Data Sheet July 2014 00813-0100-4841, Rev DA Rosemount 3490 Series 4 20 ma + HART Compatible Controller Field mounted controller with integral multi-function LCD and keypad Tough weatherproof wall

More information

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters Product Data Sheet Non-contacting measurement with no moving parts Fast and simple to install and configure Continuous measurement of level, contents (volume), or open channel flow MCERTS certified version

More information

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

MSM400 Ultrasonic Suspended Solids Monitoring and Control System Product Data Sheet MSM400 Ultrasonic Suspended Solids Monitoring and Control System Continuous sludge discharge monitor for up to 50% suspended solid The MSM400 system contains a control unit and either

More information

Annubar Flowmeter Series

Annubar Flowmeter Series Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA

More information

Rosemount 2090P Pulp and Paper Pressure Transmitter

Rosemount 2090P Pulp and Paper Pressure Transmitter Product Data Sheet Rosemount 2090P Pulp and Paper Pressure Transmitter Rosemount 2090P 1-inch flush mount compatible with a PMC process connection, or 1 1 /2-inch threaded mounting connection Absolute

More information

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents Product Data Sheet Intrinsically Safe design enables ability to perform routine maintenance in hazardous areas Predictable life specified under installed conditions Robust design for use in harsh environments

More information

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C) Product Data Sheet December 2012 00813-0100-4027, Rev BB Rosemount 4500 Hygienic Pressure Transmitter ProductDiscontinued R 37-01 Hygienic design conforms to 3-A and EHEDG standards Demonstrated best-in-class

More information

Rosemount 2140 and 2140:SIS Level Detectors

Rosemount 2140 and 2140:SIS Level Detectors Product Data Sheet 00813-0100-4140, Rev BB Rosemount 2140 and 2140:SIS Level Detectors Vibrating ork Integrates into existing wired HART loops of automated systems without extra wiring costs Switch between

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

Rosemount 4500 Hygienic Pressure Transmitter

Rosemount 4500 Hygienic Pressure Transmitter Product Data Sheet Rosemount 4500 Rosemount 4500 Hygienic Pressure Transmitter Hygienic design conforms to 3-A and EHEDG standards Demonstrated best-in-class performance during SIP/CIP for process temperatures

More information

Mobrey MCU900 Series Universal Control Unit

Mobrey MCU900 Series Universal Control Unit Universal Control Unit Intrinsically Safe power supply to transmitter 4 20mA HART input Isolated 4 20mA output Five control relays Multi-function back lit display Wall or panel mount Pre-programmed linearization:

More information

M-Switch Float Operated Liquid Level Switch

M-Switch Float Operated Liquid Level Switch Product Data Sheet M-Switch Float Operated Liquid Level Switch Reliably detects the liquid level to give a voltage free contact operation for alarm signalling or as part of a pump control system Small

More information

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 2090F Hygienic Pressure Transmitter Hygienic Pressure Transmitter Conforms to 3-A Sanitary s Features CIP/SIP service for process temperatures up to 284 F (140 C) Absolute or gage pressure ranges from 0-1.5 to 0-300 psi Mounts with either

More information

Rosemount 752 Fieldbus Remote Indicator

Rosemount 752 Fieldbus Remote Indicator Product Data Sheet Rosemount 752 Rosemount 752 Fieldbus Remote Indicator ROSEMOUNT 752 DELIVERS: Two-wire segment powered device Displays up to 8 values Link Master Capability Optional PID, Characterizer,

More information

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 2088 Absolute and Gage Pressure Transmitter Product Data Sheet Rosemount 2088 Rosemount 2088 Absolute and Gage Pressure Transmitter Performance of 0.075% with High Accuracy option Lightweight, compact design for cost effective installation Protocols

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Rosemount 3490 Series 4 20 ma + HART Compatible Controller 00825-0200-4841, Rev AB Rosemount 3490 Series 4 20 ma + HART Compatible Controller Failure to follow safe installation guidelines could result in death or serious injury The Rosemount 3490 Series Control

More information

Rosemount 2110 Level Switch

Rosemount 2110 Level Switch Rosemount 2110 Level Switch Vibrating Fork Reference Manual Reference Manual Title Page Rosemount 2110 Level Switch Vibrating Fork Read this manual before working with the product. For personal and system

More information

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014 Rosemount Pipe Clamp Sensor Reference Manual Reference Manual Title Page The Rosemount 0085 Pipe Clamp Sensor NOTICE Read this manual before working with the product. For personal and system safety, and

More information

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

SmartPower Solutions. Quick Start Guide , Rev CA March 2015 SmartPower Solutions 00825-0100-4701, Rev CA NOTICE This guide provides basic guidelines for the SmartPower family of products. It does not provide instructions for detailed configuration, diagnostics,

More information

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol Sanitary Pressure Transmitter with HART Protocol A TRADITION OF EXCELLENCE IN PERFORMANCE Conforms to 3-A Sanitary Standards Features CIP/SIP service with an upper temperature limit of 284 F (140 C) USDA

More information

Rosemount 2160 Wireless Vibrating Fork Level Switch

Rosemount 2160 Wireless Vibrating Fork Level Switch January 2012 Rosemount 2160 Rosemount 2160 Wireless Vibrating Fork Level Switch Start Considerations and Recommendations Step 1: Physical Installation Step 2: Verify Operation Step 3: Reference Information

More information

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017 Rosemount 214C Sensor 00825-0400-2654, Rev AF NOTICE This guide provides basic guidelines for Rosemount 214C Sensor models. If the sensor was ordered assembled to a temperature thermowell or transmitter,

More information

Rosemount 4500 Hygienic Pressure Transmitter. Start

Rosemount 4500 Hygienic Pressure Transmitter. Start Quick Installation Guide June 2007 Rosemount 4500 Rosemount 4500 Hygienic Pressure Transmitter ProductDiscontinued Start Step 1: Mount the Transmitter Step 2: Set the Switches Step 3: Connect Wiring and

More information

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Rosemount 752 FOUNDATION Fieldbus Remote Indicator Rosemount 752 FOUNDATION Fieldbus Remote Indicator Product Data Sheet 00813-0100-4377, Rev FA Two-wire segment powered device Displays up to eight values Link Master Capability Optional PID, Characterizer,

More information

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016 Rosemount 0085 Pipe Clamp Sensor Assembly 00825-0100-4952, Rev CA NOTICE This guide provides basic guidelines for Rosemount 0085 Pipe Clamp Sensor. It does not provide instructions for configuration, diagnostics,

More information

Ar-Mite TM Low Flow Armored Flowmeter

Ar-Mite TM Low Flow Armored Flowmeter Data Sheet Brooks Ar-Mite TM MT 3750C Ar-Mite TM Low Flow Armored Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm

More information

Ultrasonic Point Level Switches

Ultrasonic Point Level Switches see more at SORInc.com Request Quote Ultrasonic Point Level Switches Ultrasonic point level switches are a cost-effective solution for your applications. Installation requires mounting the sensor (threaded

More information

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012 Start Step 1: Physical Installation Step 2: Verify Operation Disposal/Recycling of Depleted Power Modules Product Certifications EC Declaration of Conformity End 00825-0100-4701[ 2012 Rosemount Inc. All

More information

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016 Rosemount 148 Temperature Transmitter 00825-0100-4148, Rev GA NOTICE This guide provides basic guidelines for the Rosemount 148. It does not provide instructions for detailed configuration, diagnostics,

More information

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 2090F Hygienic Pressure Transmitter Rosemount 2090F Hygienic Pressure Transmitter Product Data Sheet November 2016 00813-0100-4698, Rev FC Conforms to 3-A Sanitary Standards Features CIP/SIP service for process temperatures up to 284 F (140

More information

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

Rosemount 2088, 2090P, and 2090F Pressure Transmitters April 2013 Rosemount 2088 and 2090 Rosemount 2088, 2090P, and 2090F Pressure Transmitters with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol Start Step 1: Mount the Transmitter Step 2: Set the Jumpers

More information

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly Quick Start Guide 00825-0200-2654, Rev EA Rosemount 0065/0185 Sensor Assembly Quick Start Guide NOTICE This guide provides basic guidelines for Rosemount 0065 and 0185 Sensor models. It does not provide

More information

Rosemount 3051S Electronic Remote Sensors

Rosemount 3051S Electronic Remote Sensors Rosemount 3051S Electronic Remote Sensors Reach New Heights with Your Instrumentation A New Answer to an Old Problem Everyone has an installation that consumes time and resources, whether it s a distillation

More information

Rosemount 3095MFC Compact Orifice Mass Flowmeter

Rosemount 3095MFC Compact Orifice Mass Flowmeter Rosemount 3095MFC Compact Orifice Mass Flowmeter SPECIFICATIONS Performance System Reference Accuracy Percent (%) of mass flow rate TABLE 11. 3095MFC Compact Orifice Mass Flowmeter TYPE Repeatability ±0.1%

More information

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 2088 Absolute and Gage Pressure Transmitter Product Data Sheet Rosemount 2088 Rosemount 2088 Absolute and Gage Pressure Transmitter Absolute and gage pressure ranges from 0 1.5 psi to 0 4,000 psi (0 0.1 to 0 276 bar) Performance of 0.075% with high

More information

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 2090F Hygienic Pressure Transmitter Rosemount 2090F Hygienic Pressure Transmitter Product Data Sheet December 2017 00813-0100-4698, Rev GA Conforms to 3-A Sanitary Standards Features CIP/SIP service for process temperatures up to 284 F (140

More information

Rosemount High Density Temperature Measurement. Simplify Your Project

Rosemount High Density Temperature Measurement. Simplify Your Project Rosemount High Density Temperature Measurement Simplify Your Project 848 Balancing Project Risk is a Daunting Challenge Emerson s approach to temperature measurement can help lower the risk of budget overruns

More information

Rosemount 3051CFP Integral Orifice Flowmeter

Rosemount 3051CFP Integral Orifice Flowmeter December 2013 Rosemount 3051 Rosemount 3051CFP Integral Orifice Flowmeter See Specifications on page 47 and options for more details on each configuration. Rosemount 3051CFP Integral Orifice Flowmeters

More information

Sanitary Pressure Transmitter

Sanitary Pressure Transmitter Product Data Sheet 00813-0100-4698 Sanitary Pressure Transmitter A TRADITION OF EXCELLENCE IN PERFORMANCE Absolute or gage pressure ranges from 0 3 to 0 800 psi 0.20% reference accuracy, including linearity,

More information

Rosemount 4600 Oil & Gas Panel Pressure Transmitter

Rosemount 4600 Oil & Gas Panel Pressure Transmitter Product Data Sheet October 2017 00813-0100-4022, Rev LA Rosemount 4600 Oil & Gas Panel Pressure Transmitter A compact, lightweight, all-welded stainless steel design Up to 40:1 rangeability for increased

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview The compact flowmeter SITRANS FC410 can be ordered for industrial, hygienic or NAMUR service. Intended for integration into OEM skids, machines or pre-assembled plant systems, the flowmeter is

More information

Rosemount 702 Wireless Discrete Transmitter

Rosemount 702 Wireless Discrete Transmitter August 2009 Rosemount 702 Rosemount 702 Wireless Discrete Transmitter Start Step 1: Physical Installation Step 2: Verify Operation Step 3: Reference Information Product Certifications EC Declaration of

More information

VersaFlow Coriolis 100 Mass Flow Sensor Technical Datasheet. Specification

VersaFlow Coriolis 100 Mass Flow Sensor Technical Datasheet. Specification VersaFlow Coriolis 100 Mass Flow Sensor Technical Datasheet 34-VF-03-09 29 TH May, 2009 Specification The universal solution for the process industry VERSAFLOW is the only sensor for mass flow in its class

More information

Ultrasonic Switches. Features & Benefits

Ultrasonic Switches. Features & Benefits Why use an ultrasonic switch over other level technologies? Depending upon your application, there may be three or four technologies equally suited for your application; however; only one will be the best

More information

Absolute and Gage Pressure Transmitter

Absolute and Gage Pressure Transmitter Product Data Sheet 0083-000-4699 Absolute and Gage Pressure Transmitter ATRADITION OF EXCELLENCE IN THE PULP AND PAPER INDUSTRY Mounts flush to process media -inch flush mount compatible with a PMC process

More information

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013 Rosemount 248 Temperature Transmitter 00825-0100-4825, Rev. EA NOTICE This installation guide provides basic guidelines for the Rosemount 248 Wireless. It does not provide instructions for detailed configuration,

More information

Rosemount Functional Safety Manual. Manual Supplement , Rev AF March 2015

Rosemount Functional Safety Manual. Manual Supplement , Rev AF March 2015 Rosemount 2120 Functional Safety Manual Manual Supplement Manual Supplement Contents Contents 1Section 1: Introduction 1.1 Scope and purpose of the safety manual.................................. 1 1.2

More information

ABB MEASUREMENT & ANALY TICS DATA SHEET. RS85 Vibrating fork level switch

ABB MEASUREMENT & ANALY TICS DATA SHEET. RS85 Vibrating fork level switch ABB MEASUREMENT & ANALY TICS DATA SHEET RS85 Vibrating fork level switch 2 RS 8 5 VI BR ATI N G FOR KL EVEL SW ITC H DS/RS8 5-E N RE V. S Measurement made easy Multi option liquid level switch K TEK Level

More information

Brooks MT3750 Low Flow Armored Flowmeter

Brooks MT3750 Low Flow Armored Flowmeter Brooks MT3750 Low Flow Armored Flowmeter ArMite TM Model MT3750 Metal Tube Flowmeter ArMite TM Model MT3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm Benefits: Wetted Parts made from Stainless

More information

Enraf Servo Gauge 854 ATG

Enraf Servo Gauge 854 ATG Enraf Servo Gauge 854 ATG Setting the standard in gauging. From the company that pioneered development of modern tank gauges, Honeywell s 854 Automatic Tank Gauge has become an industry standard all over

More information

Quick Start Guide , Rev DA December Rosemount Volume 1 Sensor Assembly

Quick Start Guide , Rev DA December Rosemount Volume 1 Sensor Assembly Quick Start Guide 00825-0300-2654, Rev DA Rosemount Volume 1 Sensor Assembly Quick Start Guide NOTICE This guide provides basic guidelines for Rosemount 0068, 0078, and 0183 Sensor models. It does not

More information

Quick Start Guide , Rev. BB February Rosemount 1495 Orifice Plate Rosemount 1496 Orifice Flange Union

Quick Start Guide , Rev. BB February Rosemount 1495 Orifice Plate Rosemount 1496 Orifice Flange Union 00825-0100-4792, Rev. BB Rosemount 1495 Orifice Plate Rosemount 1496 Orifice Flange Union NOTICE This installation guide provides basic guidelines for Rosemount 1495 Conditioning Orifice Plate. It does

More information

Enraf Servo Gauge 854 XTG

Enraf Servo Gauge 854 XTG Enraf Servo Gauge 854 XTG Cut costs, not repeatability. Honeywell s 854 XTG servo gauge is a high performance alternative to other tank level measurement technologies such as radar tank level gauges. It

More information

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology Data Sheet Brooks Model MT 3810 Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology GENERAL FEATURES Broad range of flow capacities 5% Full scale accuracy

More information

Sensall Sapphire. Thermo MeasureTech ULTRASONIC POINT LEVEL SYSTEM

Sensall Sapphire. Thermo MeasureTech ULTRASONIC POINT LEVEL SYSTEM ULTRASONIC POINT LEVEL SYSTEM Introduction Compliance with growing government regulations mandates tighter level controls with advanced diagnostics to avoid releases, overspills and costly environmental

More information

Level Measurement Continuous level measurement Ultrasonic transmitters

Level Measurement Continuous level measurement Ultrasonic transmitters Overview Configuration is a short-range integrated ultrasonic level transmitter. This intrinsically safe, 2 wire, 4 to 20 ma loop powered transmitter is ideal for liquids, slurries, and bulk materials

More information

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,

More information

Rosemount 3051CFC Compact Flowmeter

Rosemount 3051CFC Compact Flowmeter CFC Compact Flowmeter CFC Compact Flowmeters provide a quick, reliable installation between existing raised face flanges. Depending on your application needs, you can reduce energy loss with the Compact

More information

Rosemount 3051L Level Transmitter

Rosemount 3051L Level Transmitter Rosemount 3051 December 2013 Rosemount 3051L Level Transmitter The Rosemount 3051L Level transmitter combines the performance and capabilities of Rosemount 3051 transmitters with the reliability and quality

More information

MT3750C Series. Metal Tube Variable Area Flowmeters. Ships in 5 days. Overview. Product Description. Features. Variable Area

MT3750C Series. Metal Tube Variable Area Flowmeters. Ships in 5 days. Overview. Product Description. Features. Variable Area DS-VA-MT3750C-eng September, 2017 Data Sheet MT3750C Series MT3750C Series Ships in 5 days Overview Variable Area Metal Tube Variable Area Flowmeters Brooks MT3750 meter operation is based on the variable

More information

MT3750C Series. Metal Tube Variable Area Flowmeters. Overview. Product Description. Features. Variable Area

MT3750C Series. Metal Tube Variable Area Flowmeters. Overview. Product Description. Features. Variable Area DS-VA-MT3750C-eng March, 2015 Data Sheet MT3750C Series MT3750C Series Variable Area Metal Tube Variable Area Flowmeters Overview Brooks MT3750 meter operation is based on the variable area principle.

More information

Mobrey Magnetic Level Switches

Mobrey Magnetic Level Switches Horizontal Float Switch Mobrey Magnetic Level Switches www.mobrey.com Horizontal Float Switch Contents Introduction Scope and Purpose of the Safety Manual...page 3 Skill Level Requirement...page 3 Terms,

More information

Rosemount 8800D Series Vortex Flowmeter

Rosemount 8800D Series Vortex Flowmeter Product Data Sheet May 2013 00813-0100-4004, Rev JB Rosemount 8800D Series Vortex Flowmeter Hart and FOUNDATION fieldbus Protocols All welded, non-clog design provides maximum performance, reliability

More information

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017 Rosemount 0085 Pipe Clamp Sensor Assembly Quick Start Guide 00825-0100-4952, Rev DC Quick Start Guide NOTICE This guide provides basic guidelines for Rosemount 0085 Pipe Clamp Sensor. It does not provide

More information

Rosemount 8800D Series Vortex Flowmeter

Rosemount 8800D Series Vortex Flowmeter Quick Installation Guide Rosemount 8800D Rosemount 8800D Series Vortex Flowmeter Start Step 1: Mount the Flowmeter Step 2: Consider Housing Rotation Step 3: Set Jumpers and Switches Step 4: Connect Wiring

More information

Laser Level Measurement Products. Introducing the New LLT100

Laser Level Measurement Products. Introducing the New LLT100 Laser Level Measurement Products BU Measurement and Analytics, June Introducing the New LLT100 Slide 1 Introducing the LLT100 Lasers for level: Now everything is possible The LLT100 revolutionizes the

More information

Emerson Wireless SmartPower Solutions

Emerson Wireless SmartPower Solutions Product Data Sheet 00813-0100-4701 Rev CA Emerson Wireless SmartPower Solutions Intrinsically Safe design enables routine maintenance in hazardous areas Predictable life specified under installed conditions

More information

Glass Tube Variable Area Flowmeter

Glass Tube Variable Area Flowmeter GT 1000 Series Models 1020, 1024, 1026, 1027 Design Specifications DS-GT 1000 April, 1997 (Supersedes issue dated December, 1996) Glass Tube Variable Area Flowmeter Wide choice of application-specific

More information

Rosemount 248 Temperature Transmitter

Rosemount 248 Temperature Transmitter Product Data Sheet November 2013 00813-0100-4825, Rev KA Rosemount 248 Temperature Transmitter Basic temperature transmitter offers a reliable solution for temperature monitoring points transmitter design

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Rosemount 2051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol

Rosemount 2051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol Quick Installation Guide August 2009 Rosemount 2051 Rosemount 2051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol Start Step 1: Mount the Transmitter Step 2: Consider Housing

More information

Sapphire ULTRASONIC POINT LEVEL SYSTEM

Sapphire ULTRASONIC POINT LEVEL SYSTEM ULTRASONIC POINT LEVEL SYSTEM Introduction Compliance with growing government regulations mandates tighter level controls with advanced diagnostics to avoid releases, overspills and costly environmental

More information

MT3809G Series. Data Sheet. Metal Tube Variable Area Flowmeters. Overview. Product Description. Variable Area

MT3809G Series. Data Sheet. Metal Tube Variable Area Flowmeters. Overview. Product Description. Variable Area Data Sheet MT3809G Series MT3809G General Purpose Housing Variable Area Metal Tube Variable Area Flowmeters Overview Brooks MT3809 meter operation is based on the variable area principle. The all metal

More information

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level Measurement Continuous level measurement - Ultrasonic transmitters Overview Configuration Parabolic mounting is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels, and simple process vessels.

More information

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Brooks MT3600 Series Metal Tube Variable Area Flowmeters Data Sheet Flanged, NPT or socket-welded connections 10% full scale accuracy Disassembly for cleaning without removal from the process line Standard direct reading, detachable scales Permanent magnetic

More information

Continuous level measurement Ultrasonic transmitters

Continuous level measurement Ultrasonic transmitters Overview Configuration Parabolic mounting is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels, and simple process vessels.

More information

Net Safety ST3 XChem Toxic Gas Sensor

Net Safety ST3 XChem Toxic Gas Sensor Product Data Sheet 00813-0100-4303, Rev AA Net Safety ST3 XChem Toxic Gas Sensor Millennium II Series Sensors Net Safety ST3 Overview The Net Safety ST3 XChem series of electrochemical toxic gas sensors

More information

Quick Start Guide , Rev CB May Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol

Quick Start Guide , Rev CB May Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol Quick Start Guide 00825-0100-4834, Rev CB Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol Quick Start Guide NOTICE NOTICE This guide provides basic guidelines for the Rosemount

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000

More information

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical

More information

Rosemount 3051 Pressure Transmitter Includes Transmitter Option TR ProductDiscontinued. Start

Rosemount 3051 Pressure Transmitter Includes Transmitter Option TR ProductDiscontinued. Start Quick Installation Guide June 2009 Rosemount 3051 Rosemount 3051 Pressure Transmitter Includes Transmitter Option TR ProductDiscontinued Start Step 1: Mount the Transmitter Step 2: Consider Housing Rotation

More information

Rosemount 1595 Conditioning Orifice Plate

Rosemount 1595 Conditioning Orifice Plate Quick Installation Guide December 2007 Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate Start Step 1: Primary Element Location Step 2: Primary Element Orientation Step 3: Primary Element Installation

More information

Specifications - Installation and Operating Instructions 2X 1/2 NPT OR M20 ELECTRICAL ENTRY. 3/4 NPT or 3/4 BSPT 5/8 [15.88]

Specifications - Installation and Operating Instructions 2X 1/2 NPT OR M20 ELECTRICAL ENTRY. 3/4 NPT or 3/4 BSPT 5/8 [15.88] Series PMT2 Particulate Transmitter Specifications - Installation and Operating Instructions Bulletin PC-PMT2 2X 1/2 NPT OR M20 ELECTRICAL ENTRY THREADED MOUNT Probe A Length in [mm] 3 3 [76.20] 5 5 [127.00]

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 50 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 50 mm Installation non-flush Output polarity NAMUR

More information

Rosemount 3051HT Hygienic Pressure Transmitter

Rosemount 3051HT Hygienic Pressure Transmitter 00825-0100-4091, Rev CA Rosemount 3051HT Hygienic Pressure Transmitter with 4 20 ma HART Revision 5 and 7 Protocol Note Before installing the transmitter, confirm the correct device driver is loaded on

More information

Rosemount 4600 Oil & Gas Panel Pressure Transmitter. Quick Start Guide , Rev GA September 2017

Rosemount 4600 Oil & Gas Panel Pressure Transmitter. Quick Start Guide , Rev GA September 2017 Rosemount 4600 Oil & Gas Panel Pressure Transmitter 00825-0100-4022, Rev GA NOTICE NOTICE This guide provides basic guidelines for the Rosemount 4600 Oil & Gas Panel Pressure Transmitter. It does not provide

More information

Certification Supplement Manual

Certification Supplement Manual SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 5 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EU DECLARATION OF CONFORMITY 3 EUROPEAN

More information

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration Overview Configuration is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels and simple process vessels. Benefits Continuous

More information

Vibracon LVL-A* Level limit switch for liquids, compact design

Vibracon LVL-A* Level limit switch for liquids, compact design Technical Information TI 364O/98/en/.07 8905 /07 0 Vibracon LVL-A* Level limit switch for liquids, compact design Application The Vibracon LVL-A* is a level limit switch for all kinds of fluids and is

More information

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74 AM54 Instruction Bulletin North American Installation Addendum Document Number PN25016 Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen It uses a high performance

More information