GCZ4500B CONNECTION DIAGRAM GCZ 4500 B 24 V DC

Size: px
Start display at page:

Download "GCZ4500B CONNECTION DIAGRAM GCZ 4500 B 24 V DC"

Transcription

1 GCZ500B CONNECTION DIAGRAM GCZ 500 B 2 V DC

2 Example of connection Sensor: GMF 30 E (elektrochemical, for toxic gases or oxygen) max. number connected to a control unit: 120 Sensor combination: 2 sensors with a small wire distance <2m Sensor combination: 2 x GMF 30 E (elektrochemical, for toxic gases or oxygen) max. number to a control unit: 80 up to 8 cable harness for sensors Sensor combination: GMF 30 E (elektrochemical, for toxic gases or oxygen) + GMF 230 H or GMF 330 P (semiconductor resp. pellistor) for refrigerants or combustible gases) max. numbers to a control unit: 50 CONTROL-ZENTRALE B 100 O2 20,9 Vol% A3 MW1 20,9 MW2 20,9 Alarm display Power Ready Alarm Ventilator 2 Ventilator 1 Defekt Alarm Service RESET GCZ 500 B Concentration display ESC MENU ENTER B+ A- A+ B- Menu Alarm zones with LED-illuminated transparents GASALARM GASALARM GASALARM B1 B1 toxical / O2 B1 toxical / O2 B1 GLT + ventilation control GASALARM GASALARM GASALARM toxical or B2 combustible or B2 toxical / O2 B2 combustible/ refrigerant B2 23 AC mains supply GLT GASALARM GASALARM GASALARM oxygen B25 refrigerantl B11 toxical / O2 toxical / O2 B33 B3 toxical / O2 combustible/ refrigerant B19 B20 2V DC 23 AC USV-BUS GASALARM GASALARM GASALARM Cable type: JY(St)Y2x2x0,8 Harness lenght: up to 0m Sensor number: up to 11 Calculation: n=5000/lenght[m] Cable type: JY(St)Y2x2x0,8 Harness lenght: up to 680m Sensor combinations: up to 17 Calculation: n=11500/lenght[m] Cable type: JY(St)Y2x2x0,8 JY(St)Y3x2x0,8 Harness lenght: up to 00m up to 560m Sensor combinations: up to 10 up to 1 Calulation: n=000/lenght[m] n=9500/lenght[m] Cable type: NYM 5x1,5mm² Cable lenght: 200 m 5 transparents 300 m 30 transparents 500 m 20 transparents Calculation: n=9000/lenght[m]

3 POWER SUPPLY CONNECTION GCZ500B: 2V F0 T2A F1 M10A F2 M10A F3 M10A F M10A CPU 1 2 ZONE 1 2V DC 3 ZONE 2 2V DC 5 6 ZONE 3 2V DC 7 8 ZONE 2V DC X3 - spreading X1 PE - spreading 2 V power supply PE PE V PE 2 1 PE 2 V DC UPS (USV-B1)

4 DIGITAL INPUTS X DIGITAL INPUTS X RESET HORN RESET ALARM Ventilation ALARM 1 ALARM 2 ALARM 3 RE- SERVE USV failure External push-button X

5 PERIPHERAL DEVICE TERMINAL X5 BUS 9+10 / RS Gateways LON / PB / EIB / SPS X5 BUS / RS 85 A B A B Peripheral devices

6 SENSOR CONNECTION X6 max. 8 BUS cable can be connected directly, furthermore via an optional junction-box BUS 1..8 / RS 85 A B red yellow wb Shield Attention A ring closure is not allowed. Instead, the sensor be divided into multiple harnesses! BUS 1..8 / RS 85 A B red green blue white (gn) Shield JY(St)Y 2x2x0,8 white black JY(St)Y 3x2x0,8 white (ye) yellow sensor sensor sensor sensor sensor sensor sensor sensor Sensor(combi) Cable type: JY(St)Y 2x2x0,8 Cabel type: JY(St)Y 3x2x0,8 Max. number of sensors Sensor number n / max. Sensor number n / max. lenght[m] connected to each control BUS-harness lenght[m] BUS-harness unit GMF 30 E n = / lenght[m] 1000 n = / lenght[m] GMF 30 E + GMF 30 E n = / lenght[m] 680 n = / lenght[m] GMF 330 P n = 5000 / lenght[m] 0 n = / lenght[m] GMF 30 E + GMF 330 P n = 000 / lenght[m] 00 n = 9500 / lenght[m] GMF 300 Z n = 1100 / lenght[m] 600 n = 2100 / lenght[m] GMF 300 Z + GMF 700 IR n = 320 / lenght[m] 230 n = 600 / lenght[m] 60 30

7 COLLECTIVE ALARM OUTPUTS Relay GSM and K5.1 are negated (shown in alarm status) Relay GSM Unit defect Relay K5.1 Unit defect Relay K5.2 ALARM 2 Relay K Accumulative unit defect indication to central building control system (NCC) Collective pre-alarm to CBCS (NC) Collective main alarm to CBCS (NC) CBCS RESERVE CBCS CBCS

8 ALARM ZONE RELAY MODULE DIAGRAM X7.1 (Zone 1) Relays K1.1 and K1.2 are negated (shown in alarm status) DC Relay K1.1 ALARM 1 Relay K1.2 Relay K1.3 ALARM 2 Relay K1. Horns Relay K1.5 Warning lights max. 10A / 230 VAC F1 Zone 1 M10A X3 1 2 X1 Ventilation control (NC) to valve control H-Switch max. A / 2 VDC ALARM 2, flashbulb 1 2 H-Switch-Modul GND +Out Connecting cable grey brown NYM 5x1,5mm² black blue Jumper plug for alternating operation 1 2 WL Hupe WL Hupe 5 LT Junction box +1 2x0,8mm² max. 30 connection boxes or warning lights 300m NYM 5x1, 5mm ² in alternating operation (jumper connector plugged in half the number of tansparents) any other calculation: n = 9000/Länge [m] X Distribution in blocks NYM 3x1,5mm² Flashbulbs NYM 5x1,5mm² Brückenstecker für Wechselbetrieb 1 2 WL Hupe WL Hupe 5 5 LT Junction box +1 Connecting cable 2x0,8mm²

9 ALARM ZONE RELAY MODULE DIAGRAM X7.2 (Zone 2) Relay K2.1 and K2.2 are negated (shown in alarm status) DC Relay K2.1 ALARM 1 Relay K2.2 Relay K2.3 ALARM 2 Relay K2. Horns Relay K2.5 Warning lights max. 10A / 230 VAC F2 Zone 2 M10A X3 3 X1 Ventilation control (NC) to valve control H-Switch max. A / 2 VDC ALARM 2, flashbulb 1 2 H-Switch-Modul GND +Out Connecting cable grey brown NYM 5x1,5mm² black blue Jumper plug for alternating operation 1 2 WL Hupe WL Hupe 5 LT Junction box +1 2x0,8mm² max. 30 connection boxes or warning lights 300m NYM 5x1, 5mm ² in alternating operation (jumper connector plugged in half the number of tansparents) any other calculation: n = 9000/Länge [m] X Distribution in blocks NYM 3x1,5mm² Flashbulbs NYM 5x1,5mm² Brückenstecker für Wechselbetrieb 1 2 WL Hupe WL Hupe 5 5 LT Junction box +1 Connecting cable 2x0,8mm²

10 ALARM ZONE RELAY MODULE DIAGRAM X7.3 (Zone 3) Relay K3.1 and K3.2 are negated (shown in alarm status) DC Relay 3.1 ALARM 1 Relay K3.2 Relay K3.3 ALARM 2 Relay K3. Horns Relay K3.5 Warning lights max. 10A / 230 VAC F3 Zone 3 M10A X3 5 6 X1 Ventilation control (NC) to valve control H-Switch max. A / 2 VDC ALARM 2, flashbulb 1 2 H-Switch-Modul GND +Out Connecting cable grey brown NYM 5x1,5mm² black blue Jumper plug for alternating operation 1 2 WL Hupe WL Hupe 5 LT Junction box +1 2x0,8mm² max. 30 connection boxes or warning lights 300m NYM 5x1, 5mm ² in alternating operation (jumper connector plugged in half the number of tansparents) any other calculation: n = 9000/Länge [m] X Distribution in blocks NYM 3x1,5mm² Flashbulbs NYM 5x1,5mm² Brückenstecker für Wechselbetrieb 1 2 WL Hupe WL Hupe 5 5 LT Junction box +1 Connecting cable 2x0,8mm²

11 ALARM ZONE RELAY MODULE DIAGRAM X7. (Zone ) Relay K.1 and K.2 are negated (shown in alarm status) DC Relay.1 ALARM 1 Relay K.2 Relay K.3 ALARM 2 Relay K. Horns Relay K.5 Warning lights max. 10A / 230 VAC F Zone M10A X3 7 8 X1 Ventilation control (NC) to valve control H-Switch max. A / 2 VDC ALARM 2, flashbulb 1 2 H-Switch-Modul GND +Out Connecting cable grey brown NYM 5x1,5mm² black blue Jumper plug for alternating operation 1 2 WL Hupe WL Hupe 5 LT Junction box +1 2x0,8mm² max. 30 connection boxes or warning lights 300m NYM 5x1, 5mm ² in alternating operation (jumper connector plugged in half the number of tansparents) any other calculation: n = 9000/Länge [m] X Distribution in blocks NYM 3x1,5mm² Flashbulbs NYM 5x1,5mm² Brückenstecker für Wechselbetrieb 1 2 WL Hupe WL Hupe 5 5 LT Junction box +1 Connecting cable 2x0,8mm²

12 Standard Relay Occupancy Zone 1 Zone 2 Zone 3 Zone K K K K GWU WL GWU WL GWU WL GWU WL Warning light Warning light Warning light Warning light K K K K GWU HORN Horn GWU HORN Horn GWU HORN Horn GWU HORN Horn K K K K High side driver FL Flashlight Pre-alarm High side driver FL High side driver FL High side driver FL Flashlight Pre-alarm Flashlight Pre-alarm Flashlight Pre-alarm K K K K VC VC VC VC VC VC VC VC Valve control Main alarm Valve control Main alarm Valve control Main alarm Valve control Main alarm K K K K VLC VLC Ventilation control Fault+Prealalarm Ventilation control Fault+Prealarm Collective alarms Ventilation control Fault+Prealarm Ventilation control Fault+Prealarm GSM K K K CBCS Fault report CBCS CBCS VLC Reserve Fault report VLC CBCS CBCS VLC VLC CBCS Collective pre-alarm CBCS CBCS VLC VLC CBCS Collective main alarm Umwelt- und Sicherheitstechnik Standard Relay Occupancy GCZ 500 B Object: Place: Date: Name:

13 Wiring diagram LED-illuminated warning transparent LT - GA 2V DC resp. USV 2V DC Alarm-relay of the COwarning system (clocked) Supply and control lead 5x1,5mm² Supply and control lead 5x1,5mm² Horn-relay of the COwarning system (statical) Junction box 100x100x60mm Power consumption: 2 W Input voltage: DC The power consumption is halved, when in every second junction box the bridge for alternating operation is plugged, because then only every second transparent lights up at the same time buzzer Cable length standard: 1m modern LED-illuminated warning transparent pictogram GASALARM LxWxH: 300 x 185 x 20 mm

14 Connection diagram: Flashing lights programmed relay for flashing light F M10A DC X3 1 2 X1 1 2 H-Switch max. A / 2 VDC, flashing light collective alarm H-Switch-Modul GND +Out NYM 3x1,5mm² Flashing light

15 Connection diagram: Uninteruptable Emergency Power Supply USV-B1 Ready = Battery charged >85% + mains power connected + no error Bereit (ready) Netz/Laden (Mains/Charging) Pufferbetrieb (buffer mode) Service (service required) UPS: USV-B ,V 5A/3,75 Ah // 5A/9 Ah // 10A/13 Ah Pb-battery 1x 12V 7,5 Ah / 18Ah / 26Ah T20A battery fuse Power supply unit 23=>2V DC ok Replace Battery Buffering relais max. 30 V / 0,5 A Output 2 VDC / 5A / 10A L1 N PE + - -Batt +Batt Ready Chargingand output voltage control unit Ready B 6A X1 L1 L1.1 L1.1 N N PE PE MAINS AC Mains power supply L1, N, PE to Gas warning system CBCS Central building control system Ready = Battery charged >85% + mains power connected + no device failure

16 Figure with connection diagram USV to the gas warning system GWA Power supply terminal GCS500B 2 V DC from USV-B1 USV Mains supply 23 AC

17 Wiring diagram GCZ 500 B Valve control / Gas emergency stop GASWARNING DEVICE GCZ 500 B X6 BUS 1..8 A B F1.. 2AT X3 JY(St)Y 3x2x0,8mm rd/1 ye/2b Drain a wb/2a bl/1b wire gn/3b wb/3a 1 2 Relay KZ.2 is negated (shown in alarm status) Relay KZ X1 VALVE CONTROL VST1-23 K2 T1 OFF F1 2AT () S2 Bridge H1 white L1.1 N N N PE PE PE () S1 ON K1 latchcircuit GNAa T1 GAS Emer- gency- Stop JY(St)Y 3x2x0,8mm Valve 230 V AC currentless closed GNAz T1 GAS Emergency - Stop NYM 3x 1,5 mm² L1 N PE Power 230 V AC Bridge on the last emergency stop

18 Wiring Diagram GCZ 500 B CHP Valve Controller / Gas Emergency Stop Button GAS-WARNING DEVICE GCZ 500 B Relays K5.3 and K5. are negated (shown in alarm status) CHP Valve Controller V1 Safety relay X6 BUS 1..8 A B F1.. 2AT 2 Relay K Relay K X1 S2 automatic/ bridged () open= auto T1 Gas valve OFF closed = bridged S1 () Gas valve ON ) K1A K1A ) K1B ) K1C JY(St)Y 3x2x0,8mm rt/1a ye/2b ws/2a bl/1b drain wire gn/3b ws/3a X F1 1AT X off delayed 6,5-12,5s K1A K1B K1C on delayed 6,5-12,5s X K2 X3 1 2 X 1 2 X5 1 2 Signal relay K2 ( X F2 6,3AT X7 X8 L1.1 N L1 N X9 PE PE GNAa T1 GAS- Emer- gency- Stop GNAz T1 GAS- Emer- gency- Stop 6 7 Bridge on the last emergency stop 8 9 JY(St)Y 3x2x0,8mm optional sign light bridged active Message bridged active to the PLC Message valve open to the CHP control Valve 230 V AC currentless closed L1 N PE Netz 230 V NYM 3x 1,5 mm²

19 System allocation Object: Place: Device: No.: Location: Technician: Date IB / Modification: Line discription Terminal block Voltage Room / Souce / Target /control panel USV Power 2 V DC USV-B1

20 BUS allocation Object: Place: Device: No.: Location: Technician: Date IB / Modification: BUS cable allocation (as in actual order) BUS Pcs B-No. Type Gas type Sensor/ Unit Room / (Place)

21 Notes on the periphery Object: Place: Device: No.: Location: Technician: Date IB / Modification: Notes / Wiring diagram / Terminal functions of connected devices

22 Relay allocation Modules 1..5 Object: Place: Device: No.: Location: Technician: Relay Alarm F/VA/HA Negation Potential/ contacts Date IB / Modification: Function Number No. / Room(s)Allocation / Place / Message GSM F yes 11/1 GLT "GWA failure" K5.1 K5.2 VA 11/12 GLT " GWA pre-alarm" K5.3 HA 11/12 GLT "GWA main alarm" K1.1 K1.2 K1.3 K1. K1.5 K2.1 K2.2 K2.3 K2. K2.5 K3.1 K3.2 K3.3 K3. K3.5 K.1 K.2 K.3 K. K.5 *further Infos

23 Relay allocation Modules 6..9 Object: Place: Device: No.: Location: Technician: Date IB / Modification: Relay K6.1 K6.2 K6.3 K6. K6.5 K6.3 K6. K6.5 Alarm F/VA/HA Potential/ contacts Function Negation Number No. / Room(s)Allocation / Place / Message K7.1 K7.2 K7.3 K7. K7.5 K7.3 K7. K7.5 K8.1 K8.2 K8.3 K8. K8.5 K8.3 K8. K8.5 K9.1 K9.2 K9.3 K9. K9.5 K9.6 K9.7 K9.8

24 Relay allocation Modules Object: Place: Device: No.: Location: Technician: Date IB / Modifiaction: Relay K10.1 K10.2 K10.3 K10. K10.5 K10.3 K10. K10.5 Alarm F/VA/HA Negation Potential/ contacts Function Number No. / Room(s)Allocation / Place / Message K11.1 K11.2 K11.3 K11. K11.5 K11.3 K11. K11.5 K12.1 K12.2 K12.3 K12. K12.5 K12.3 K12. K12.5 K13.1 K13.2 K13.3 K13. K13.5 K13.6 K13.7 K13.8

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: / Planungsbüro + Service: Esteraustr. 10, 56379 Holzappel Tel.: 0 64 39 / 90 19 90 Fax.: 0 64 39 / 90 19 91 E-Mail: u.ramakers@umsitec.de Entwicklung + Fertigung + Service: Heerweg 15 D, 73770 Denkendorf

More information

Multi-Gas-Controller MGC2

Multi-Gas-Controller MGC2 Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants

More information

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point Medium - Control - System Franke & Haqenest GmbH Borngasse 1a * 04600 Altenburg Tel: 03447-499 313-0 Fax: 03447-499 313-6 email: info@mcs-gaswarnanlagen.de MCS User Guide MCS GasController Microprocessor

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Chlorine gas leak detector

Chlorine gas leak detector INSTRUCTION MANUAL FOR Chlorine gas leak detector with battery back up series M 4510 C 2007 Controlmatik ABW d.o.o. 1 CONTENT 1.0 General description:... 3 2.0 The Unit... 4 3.0 Controls and Displays...

More information

PolyGard 2-channel Gas Controller MGC-03

PolyGard 2-channel Gas Controller MGC-03 PolyGard 2-channel Gas Controller MGC-03 DESCRIPTION Gas measuring and monitoring controller based on state-ofthe-art micro-technology with integrated buzzer for continuous monitoring of the ambient air

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

OPERATION MANUAL Gas Alarm Processing Unit GAZ 203 VN VN 10

OPERATION MANUAL Gas Alarm Processing Unit GAZ 203 VN VN 10 Planungsbüro + Service: Esteraustr. 10, 56379 Holzappel Tel.: 0 64 39 / 90 19 90 Fax.: 0 64 39 / 90 19 91 E-Mail: u.ramakers@umsitec.de Entwicklung + Fertigung + Service: Heerweg 15 D, 73770 Denkendorf

More information

21-light Remote Annunciator. Owner s Manual

21-light Remote Annunciator. Owner s Manual 21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With

More information

Gas Detection Unit (GDU) GDA, GDC, GDHC, GDHF, GDH

Gas Detection Unit (GDU) GDA, GDC, GDHC, GDHF, GDH 896 Installation Guide Gas Detection Unit (GDU) GDA, GDC, GDHC, GDHF, GDH Technician use only! This unit must be installed by a suitably qualified technican who will install this unit in accordance with

More information

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual BS-316 Gas detection control panel up to 16 inputs Installation operation manual Page 1 from 21 Contents 1 Operation instructions--------------------------------------------------------------------------------------------------------------------3

More information

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor

More information

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting Operation Manual GMA200-MW16 Gas detection controller for wall mounting GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, GERMANY TEL. +49 / (0)231 / 564 00 0 FAX +49 / (0)231 / 516 313

More information

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly Operation Manual GMA200-MT Gas detection controller for mounting rail assembly GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)231 / 564 00 0 FAX +49 / (0)231

More information

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen PolyGard Single Point Controller SPC-X3-XX for Toxic Gases and Oxygen DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor and

More information

User Manual. Security Systems Security System L208

User Manual. Security Systems Security System L208 User Manual Security Systems Security System L208 a Contents This hand book is a technical instruction document for the installation, commissioning and operation of the L208 intrusion alarm security system.

More information

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63 Fire Extinguishing Control Panel FS5200Е INSTRUCTION MANUAL Revision 8/01.17 Instruction Manual Page 1 1. 2. 3. 4. 4.1. 4.2. 4.2.1. 4.2.2. 4.2.3. 4.2.4. 4.2.5. 4.2.6. 4.2.7. 4.2.8. 4.2.9. 4.2.10. 4.2.11.

More information

Fire Control Panel FS4000

Fire Control Panel FS4000 Fire Control Panel FS4000 INSTRUCTION MANUAL Revision 4/02.11 Contents 1. Introduction... 4 2. Terminology... 4 3. Function... 5 4. Technical features... 5 4.1 Fire alarm lines... 5 4.2. Current thresholds

More information

20 Light Remote Annunciator

20 Light Remote Annunciator Light Remote Annunciator Owner s Manual Surface Mount Flush Mount 94-95- Standard Annunciator 94-, 94-95-, 95-4- 4- Annunciator w/remote Relay Panel 4-, 4-4-, 4-49-, 49-49-, 49- Time Multiplexed Annunciator

More information

BSR Addressable Fire Detection control panel. Installation operation manual

BSR Addressable Fire Detection control panel. Installation operation manual BSR-1116 Addressable Fire Detection control panel Installation operation manual ATTENTION!!! READ THE MANUAL BEFORE THE INSTALLATION AND PAY ATTENTION TO PARAGRAPH 2.6.3 AND 2.6.4. Page 2 from 36 Contents

More information

GMA200-MW4. User Manual. Gas detection controller for wall mounting

GMA200-MW4. User Manual. Gas detection controller for wall mounting User Manual GMA200-MW4 Gas detection controller for wall mounting GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, GERMANY TEL. +49 / (0)231 / 564 00 0 FAX +49 / (0)231 / 516 313 INFO@GFG-MBH.COM

More information

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08 GasScanner 4C Four Channel Monitor Operator s Manual MINT-0280-XX Rev. A 02/25/08 Product Warranty Matheson Tri-Gas., warrants gas alarm equipment sold by us to be free from defects in materials, workmanship,

More information

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08 GasScanner 8C Eight Channel Monitor Operator s Manual MINT-0281-XX Rev. A 01/29/08 Product Warranty Matheson Tri-Gas, Inc., warrants gas alarm equipment sold by us to be free from defects in materials,

More information

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007 PolyGard Gas Controller MGC3 Two-Channel Analog Gas Controller Serial Number _E _0907 User Manual September 2007 January 04, 2016 Revision Specifications subject to change without notice. USA 160104 Page

More information

TD80 LEVEL GAUGING & OVERFILL PREVENTION SYSTEM PRODUCT MANUAL SUPPLEMENT. TPM 005 Revision 0.0

TD80 LEVEL GAUGING & OVERFILL PREVENTION SYSTEM PRODUCT MANUAL SUPPLEMENT. TPM 005 Revision 0.0 TD80 LEVEL GAUGING & OVERFILL PREVENTION SYSTEM PRODUCT MANUAL SUPPLEMENT TPM 005 Revision 0.0 Table of Contents 1 TD80 Current Loop Option... 2 1.1 Introduction... 2 1.2 Components... 2 1.3 Operation...

More information

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment. LED Driver Module Installation Guide 1.0 Notice These instructions are for installing Radionics LED Driver Module in a fire alarm system controlled by Radionics D8024 or D10024 Fire Alarm Control Panels

More information

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) IRDH375_D00124_01_D_XXEN/07.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Product

More information

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number Worldwide Supplier of Safety Solutions GfG Instrumentation 1194 Oak Valley Drive #20 Phone: 734-769-0573 Fax: 734-769-1888 E-Mail: info@gfg-inc.com Internet: www.gfg-inc.com GMA 301 Operation Manual Part

More information

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power T M User Manual MarinaGuard Ground Fault Monitoring Panel For Marina Shore Power NAE1095810 / 03.2013 T M Bender Inc. USA: 700 Fox Chase Coatesville, PA 19320 Toll-Free: 800-356-4266 Phone: 610-383-9200

More information

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Tel: +44 (0)8 9388 Email: info@ Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel

More information

Danfoss gas detection unit Type GD Heavy Duty

Danfoss gas detection unit Type GD Heavy Duty Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

PolyGard Digital Gas Controller DGC-05 RS-485 Bus PolyGard Digital Gas Controller DGC05 RS485 DESCRIPTION Gas measuring controller series for continuous monitoring and warning of toxic, combustible and refrigerant gases and vapours. The gas controller

More information

MBZ300. Emergency power control unit. GB Installation instructions MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 PME PME. Reset.

MBZ300. Emergency power control unit. GB Installation instructions MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 PME PME. Reset. 24V 24V PME PME CM DM SM DM WM Reset Reset Emergency power control unit GB Installation instructions 1 Table of contents 1 Symbols and illustrations...3 2 Product liability...3 3 Safety instructions...3

More information

Beacon 800 Gas Monitor Operator s Manual

Beacon 800 Gas Monitor Operator s Manual Beacon 800 Gas Monitor Operator s Manual Part Number: 71-0037RK Revision: F Released: 4/18/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to be

More information

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460) Operating Manual TS400 Test Station for Microtector II Series (G450/G460) GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)2 31 / 5 64 00 0 FAX +49 / (0)2 31 /

More information

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 505 Grünberg Tel.: 060 807-0 Fax: 060 807-59 A-ISOMETER IRDH575 Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with

More information

Nitrogen Dioxide Stand-Alone Detector - Analog, ModBus

Nitrogen Dioxide Stand-Alone Detector - Analog, ModBus Features Internal function monitoring with integrated hardware watchdog Hardware and software according to SIL2 compliant development process Easy maintenance / calibration by replacing the sensor cartridge

More information

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3.

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3. TS CE Combustion Enclosures with LMV3 February 12, 2019 Description TS CE series combustion enclosure with Siemens LMV3 linkageless controller sets the new standard for combustion control and monitoring

More information

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Intelligent 2 & 4 Loop Fire Alarm Control Panels Intelligent 2 & 4 Loop Fire Alarm Control Panels Advanced has combined the latest technology with many years of fire experience, to create the Axis AX Series Intelligent Fire Alarm Control Panels. The

More information

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08 Beacon 200 Gas Monitor Operator s Manual Part Number: 71-2102RK Released: 6/6/08 Table of Contents Chapter 1: Introduction.................................................3 Overview.............................................................3

More information

FireNET Plus Wiring Instructions

FireNET Plus Wiring Instructions FireNET Plus Wiring Instructions This manual provides wiring instructions for the 1 loop and 2 loop version of the FireNET Plus panels, which supports our finest Hochiki s DCP protocol. Note: Refer to

More information

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel Synova Commissioning in no time thanks to automatic address allocation Auto-addressing makes setting dip switches, punch cards, etc. unnecessary

More information

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description SCC Inc. TS Series TS-CE Combustion Enclosures with LMV5 June 25, 2018 Description TS-CE series combustion enclosure with Siemens LMV5 linkageless controller sets the standard for combustion control and

More information

Oxygen (O2) Single-Point Gas Detection System

Oxygen (O2) Single-Point Gas Detection System Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity

More information

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel Synova TM Commissioning in no time thanks to automatic address allocation Auto-addressing makes setting dip switches unnecessary Automatic

More information

The EN54 Part 2 & 4 Fire System

The EN54 Part 2 & 4 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

Remote alarm indicator and test combination MK2430

Remote alarm indicator and test combination MK2430 Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Tel.: 040 807-0 Fax: 040 807-259 Remote alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC

More information

UV - Monitor UVT 16. Use. Description

UV - Monitor UVT 16. Use. Description UV - Monitor UVT 16 Use The UVT 16 Monitor is used to monitor signals from UV probes or sensors applied to sources of radiation, providing a control system for small items of UV equipment. Description

More information

Fire Control Panel FS5100

Fire Control Panel FS5100 Fire Control Panel FS5100 INSTRUCTION MANUAL Revision 6/02.11 Contents 1. Introduction... 5 2. Terminology... 5 3. Function... 7 4. Technical data... 7 4.1. Modules... 7 4.1.1. Type of modules... 7 4.1.2.

More information

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Revision 6/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions GRUNDFOS INSTRUCTIONS LCD 08 Installation and operating instructions Installation and operating instructions Original installation and operating instructions CONTENTS Page. Symbols used in this document.

More information

Key-Operated Switch GMA 41 / GMA 44 SW. Operation Manual

Key-Operated Switch GMA 41 / GMA 44 SW. Operation Manual Key-Operated witch GMA 41 / GMA 44 W Operation Manual Table of contents Page Introduction... 4 Key function... 4 Distinction of GMA 41/44 W models... 4 Relays... 5 P.C. boards of GMA 41/44 W... 7 Terminal

More information

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel from hazardous gases in

More information

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION 968 AFMS AFMS TECHNICAL SPECIFICATION 08/07 Ref B ATV-ELEKTRONIK GMBH WIENER STRASSE 228 A-4030 LINZ +43 732 301600 FAX. +43 732 301600 21 Page 2 Table of contents General Introduction...3 Overview...3

More information

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy. Installation manual detector and controller Code no. 20711062 Page 1/30 CONTENTS Controller... 2 Function of the Relays... 2 Gas Detectors... 2 Cabling... 4 Mechanical Installation of the gas detectors...

More information

Intelligent Single Loop Fire Alarm Control Panel

Intelligent Single Loop Fire Alarm Control Panel Intelligent Single Loop Fire Alarm Control Panel The CAX-CTL-1L Intelligent Single Loop Fire Alarm Control Panel is a member of the industry leading Axis AX Series Intelligent Fre Alarm Control Panels

More information

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2 FEATURES: Closed Loop Design (Class A Wiring) Microprocessor Based System Intelligent Distributed System Structure Quick Response Time Fire Alarm in

More information

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac- Carriers Type Universal Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art

More information

Dräger REGARD -1 Control System

Dräger REGARD -1 Control System Dräger REGARD -1 Control System The Dräger REGARD -1 is a standalone single-channel control system for the detection of toxic and Ex hazards and oxygen levels. The control system is fully configurable

More information

Entero Voice Alarm system.

Entero Voice Alarm system. Entero Voice Alarm system. Entero ESC installation menu guide Rev. 1.0 The manufacturer reserves specification privileges. Information in this manual is subject to change without prior notice or obligation.

More information

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL. Page 1 / 15 Installation and user manual Page 2 / 15 Sira s.r.l. reserves the right to make modifications to this manual and the product described herein without prior notice. Sira s.r.l. shall not be

More information

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Revision 4/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

MULTIGUARD MULTIGUARD USERS MANUAL TYPE S3/240W 26/01/2010

MULTIGUARD   MULTIGUARD   USERS MANUAL TYPE S3/240W 26/01/2010 195,00 mm N MAIN CONNECTION Description Type S3 240W Uninterruptable Power Supply is an industrial grade unit for stationary and indoor use only. ACCESS HOLE FOR OUTPUT VOLTAGE ADJUSTMENT PROTECTION UNIT

More information

AIS750 Series Alarm Annunciator

AIS750 Series Alarm Annunciator Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &

More information

Pioneer-R16 Gas Monitor Operator s Manual

Pioneer-R16 Gas Monitor Operator s Manual Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas

More information

How to modify Volvo Alarm Siren after it has given Message: Alarm system Service Required Ver. 1.2

How to modify Volvo Alarm Siren after it has given Message: Alarm system Service Required Ver. 1.2 How to modify Volvo Alarm Siren after it has given Message: Alarm system Service Required Ver. 1.2 We will show how to modify the Alarm Siren Unit without using Battery. If you are not sure or do not know

More information

MCS 4000 Control Panel

MCS 4000 Control Panel Medium Control Systeme Franke & Hagenest GmbH Borngasse 1a * 04600 Altenburg Telefon : +49 3447 499 313 0 Telefax : +49 3447 499 313 6 E-Mail : info@mcs-gaswarnanlagen.de MCS Operation Manual MCS 4000

More information

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491 Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 06401 807-0 Fax: 06401 807-59 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control

More information

SUPREMATouch Modular Fire & Gas Detection System

SUPREMATouch Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Because every life has a purpose Class Leading Fire & Gas Detection Solutions MSA s permanent gas detection systems are relied upon by a huge number of

More information

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS ELECTROPROJECT POWER SUPPLY FOR DOOR MAGNETS Innovative and carefully thought out Always the right drive ELECTROPROJECT AANDRIJFTECHNIEK ElectroProject has evolved over the last 75 years from a technical

More information

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL The LeakStopper Multizone detects the presence of water in environments where it is not supposed to be. Should water

More information

Fire control panels FC360

Fire control panels FC360 Cerberus TM FIT Fire control panels FC360 FC361-ZZ, FC361-ZA, FC361-YZ, FC361-YA Fire control panels (1-loop) for addressable peripheral devices with integrated operating unit One loop with 126 addresses

More information

Fire Control Panel FS4000

Fire Control Panel FS4000 Fire Control Panel FS4000 INSTRUCTION MANUAL Revision 11/01.17 Contents 1. Introduction... 3 2. Terminology... 3 3. Function... 4 4. Technical features... 4 4.1 Fire alarm lines... 4 4.2. Current thresholds

More information

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary

More information

User Manual. PolyGard Single Point Controller SPC-43-20XX. Single Point Gas Controller for Refrigerant Gases Serial Number _E_.

User Manual. PolyGard Single Point Controller SPC-43-20XX. Single Point Gas Controller for Refrigerant Gases Serial Number _E_. PolyGard Single Point Controller SPC-43-20XX Single Point Gas Controller for Refrigerant Gases Serial Number _E_ User Manual January 2015 Phone: 0049(0)8531/9004-0 Fax: 0049(0)8531/9004-54 Specification

More information

Fire control panels FC726 FC726-XA

Fire control panels FC726 FC726-XA Fire control panels FC726 FC726-XA Modular, pre-confectioned, microprocessor-controlled fire control panel for up to max. 1512 device addresses Integrated, user-friendly operating unit Detection and automatic

More information

DIGITAL ALARM UNIT Model ALU-AP

DIGITAL ALARM UNIT Model ALU-AP DIGITAL ALARM UNIT Model ALU-AP Description Digital alarm unit ALU-AP has the following characteristics: 1. Operates in MASTER or SLAVE mode. 2. It can connect with other devices through a RS485 network

More information

FlexiSmoke WSC 520 / WSC 540 / WSC 560 Modular smoke ventilation panel 20-60A

FlexiSmoke WSC 520 / WSC 540 / WSC 560 Modular smoke ventilation panel 20-60A Version 11 Controls for smoke and natural ventilation WSC 520 2 x WSA 017 WSC 540 4 x WSA 017 WSC 560 6 x WSA 017 2.20 Flexi WSC 520 / WSC 540 / WSC 560 odular smoke ventilation panel 20-60A Natural ventilation

More information

User Manual. PolyGard Single Point Controller SPC Single Point Gas Controller for Combustible Gases Serial Number _E_1008.

User Manual. PolyGard Single Point Controller SPC Single Point Gas Controller for Combustible Gases Serial Number _E_1008. PolyGard Single Point Controller SPC3-3300 Single Point Gas Controller for Combustible Gases Serial Number _E_1008 User Manual October, 2008 January 04, 2016 Revision PolyGard is a registered trademark

More information

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm Operating & Maintenance Manual Alert-4 Ethernet LCD Master Alarm w w w. a m i c o. c o m Contents User Responsibility 4 Introduction 4 Features 5 Description of the Alarm 5 Shipment Details 5 The Alarm

More information

TECOM SYSTEMS NETWORK MASTER

TECOM SYSTEMS NETWORK MASTER TECOM SYSTEMS NETWORK MASTER The Tecom Network Master is a cost effective, Dialler Receiver and Direct Line Network Master combined in a single modular unit. HARDWARE The unit consists of a 3RU, 19 inch

More information

SCAN200E USER S MANUAL

SCAN200E USER S MANUAL SCAN200E USER S MANUAL Code No. 2071 1052 rev. 1.4 Code No. 2071 1052 Rev. 1.4 Page 2/16 SCAN200E User s Manual Foreword This manual is for SCAN200E Controller running software version 2.03 or later. We

More information

Product Manual SZ1144

Product Manual SZ1144 Product Manual SZ1144 Refrigeration Temperature Monitor Communicating Controls Description The SZ1144 is a microprocessor-based monitoring and alarm interface designed to monitor up to four 1000 Ω platinum

More information

Beacon 410A Gas Monitor Operator s Manual

Beacon 410A Gas Monitor Operator s Manual Beacon 410A Gas Monitor Operator s Manual Part Number: 71-0397 Revision: F Released: 12/5/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be

More information

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32 User manual and installation instruction Control for Fire Ventilation RV 24-24 / RV 24-32 Fire ventilation Comfort ventilation 24VDC max. 24/32A 2 Actuator outputs 1 Fire ventilation group, 2 comfort groups

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

BURGLAR ALARM PANEL BS-468

BURGLAR ALARM PANEL BS-468 BURGLAR ALARM PANEL BS-468 Contents 1. Description... 3 2. Instructions for the user... 4 2.1Basic operations... 4 Complete system.... 4 Split system.... 4 2.2 Armed system indication... 5 2.3 Advanced

More information

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 505 Grünberg Tel.: 00 807-0 Fax: 00 807-259 Insulation monitoring device for unearthed AC/DC systems (IT systems for the supply of operating theatre

More information

DR. E. HORN GmbH / Schoenaich, Germany

DR. E. HORN GmbH / Schoenaich, Germany Manual DK002111, rev.15. June 2015 DR. E. HORN GmbH / Schoenaich, Germany Water in Oil Identification System for standalone installation: Sensor FRG00032... Connection box GHG02088-4 3x relay outputs optional:

More information

Remote Display Alarm Indicator for Oxygen monitor

Remote Display Alarm Indicator for Oxygen monitor Remote Display Alarm Indicator for Oxygen monitor (Part number 99091) The Remote Display Alarm Indicator is designed to display remote oxygen concentration information from PureAire oxygen monitors. All

More information

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491 Bender Incorporated 700 Fox Chase, Coatesville PA 1930 Tel.: (800) 356-466 Fax: (610) 383-7100 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control function

More information

LMA LINE MONITOR ALERT USER S MANUAL

LMA LINE MONITOR ALERT USER S MANUAL LMA LINE MONITOR ALERT USER S MANUAL Janus is a brand of Avire Avire Inc 415 Oser Avenue, Suite Q, Hauppauge, New York 11788 Phone: 631 864 3699 Toll Free: 800 527 9156 Fax: 631 864 2631 Email: sales.us@avire-global.com

More information

GLOBAL. InstallatIon & operation manual

GLOBAL. InstallatIon & operation manual InstallatIon & operation manual INDEX 1. INTRODUCTION... 5 2. FEATURES AND FUNCTIONS 2.1 Reporting Options... 2.2 Interfaces... 2.3 Programming... 2.4 Indicators and Controls...... 6 6 6 6 6 3. INSTALLATION...

More information

CONTROL DEVICE SLIDETRONIC HD

CONTROL DEVICE SLIDETRONIC HD CONTROL DEVICE SLIDETRONIC HD to control gravity self-closing fire gates Producer: Somati system s.r.o. Jihlavská 510/2c 664 41 Troubsko, okr.brno - venkov Tel.: 547 427 011 Fax: 547 427 013 E-mail: export@somati-system.cz

More information

REPEATER FS5200R INSTRUCTION MANUAL

REPEATER FS5200R INSTRUCTION MANUAL REPEATER FS5200R INSTRUCTION MANUAL Instruction Manual Page1 CONTENTS 1. Introduction... 3 2. Function... 3 3. Technical data... 3 4. Contents of delivery... 4 5. General information... 5 6. Duty Mode...

More information

Gas leak detection + trapped person alarm

Gas leak detection + trapped person alarm GB 555H40 Ed.0 AKO-5554 AKO-5584 AKO-5554 AKO-5584 Gas leak detection + trapped person alarm User manual 555H40 Ed.0 Index Page Versions and references...3 Equipment description...4 Warnings...5 Maintenance...5

More information

Products no longer available

Products no longer available Technical data sheet MONICO-.. Turnkey automation station MONICO-.. Forms an efficient fire protection system together with the motorisation sets BF(G)24MP Completely wired controller in matching control

More information

Contents. Outline of Product. Features of Product. Specifications of Product. Name and central function of section. Illustration of Terminal

Contents. Outline of Product. Features of Product. Specifications of Product. Name and central function of section. Illustration of Terminal DA-750 1 page Contents Outline of Product 3 page Features of Product 3 page Specifications of Product 4 page Name and central function of section 5 page Illustration of Terminal 8 page Setting of Menu

More information