Cryogenic Autofill for AGATA. I. Kojouharov GSI, Darmstadt
|
|
- Wilfrid Leonard
- 6 years ago
- Views:
Transcription
1 GSI, Darmstadt Agata week, Cologne, 0. March -. April 009
2 AGATA cryogenic Autofill System has to: Fill regularly or on exception up to 0 ATC Fill the buffer tanks (if existing) regularly or on exception Provide information on the LN status and the detector temperature the LN status and the tank pressure To send alerts if needed To interface any command signals coming in or outgoing to DSS Agata week, Cologne, 0. March -. April 009
3 Definition of the cryogenic Autofill System othe Autofill System (or Autofill) is a system dedicated to maintenance of the HPGe-detectors at cold state by LN. It implies temperature monitoring of the detectors, regular or extraordinary filling of them, and verification of the processes of temperature monitoring and filling, and taking protective measures in case of inability to maintain them at cold state. othe Autofill is supposed to be powered by the network electricity power and any battery operation of the full system or its particular section (except alerting devices) is not allowed. The network power has to be supported by UPS; othe Autofill is supposed to be built in a way to eliminate the possibility for reduction of its integrity; othe Autofill is supposed to be built in a way to allow monitoring of its operational status and alerting in case of unauthorized transition to inactive state; othe filling of the detectors can be managed automatically, semiautomatically and manually. Agata week, Cologne, 0. March -. April 009
4 Functionality of the cryogenic Autofill System oregular filling. Regular filling of any detector within given time schedule. The time schedule is variable and can be altered by the Operator; oforced fill; oextraordinary filling triggered by the temperature of the detector. The forced fill parameters can be altered by the Operator; oextraordinary filling triggered by the Operator ( Fill Now ). Software (semiautomatic) and Hardware (semiautomatic manually and full manually) features are foreseen. The filling time schedule can be reset in case of software and hardware semiautomatic Fill now and by Forced fill (Legnaro Option); overification of all (regular or forced) filling processes in order to avoid statistic or systematic errors; odisplay of the filling parameters in real time; odetector temperature monitoring and relevant actions; omeasuring the detector temperature continuously in real time (accuracy of 0. K) and reporting it; ocorrecting the temperature measured in order to compensate any systematic errors; odetecting Detector Warm temperature (0 K) and issuing warning. Threshold is variable; odetection Detector Too Warm temperature (0 K) and performs Forced Fill filling procedure. Issues warning to and reports the beginning and the end of the Forced Fill procedure. Timeout and threshold are variable ; odetection Detector Hot temperature ( K) and performs a Software Bias Shut Down (SBSD). It issues warning and reports the time of SBSD. Timeout and threshold are variable; overification of Detector Filling procedures and Detector Temperature critical thresholds ( Detector Warm, Detector Too Warm and Detector Hot ) in order to obtain a distinct definition of critical situation under when certain actions can be taken; ooptional monitoring of the LN level of the detector Dewar and Forced Fill performance at appr. 0% of the LN level. Agata week, Cologne, 0. March -. April 009
5 Structure of DSS and Autofill System ALERT TENTATIVE ARCHITECTURE OF AGATA DSS PARAMETERS DISPLAY ANALYSIS DATA BASE GENERAL ALERT GUI PC COMMUNICATION PLC PCR AUTOFILL BIAS POWER CONDITIONS SAFETY SHUT DOWN UPS DETECTORS SENSORS I.Kojouharov, GSI, Agata week, Cologne, 0. March -. April 009
6 Structure of the Autofill System Pipeline Pipeline Terminal -Tank Autofill System Det. Det. Det. Det. Det. Det. Det. Det. To Tank N Overflow Collector To Tank Autofill PS Pt00 Sensor Shut-off Valve Outflow WatchDog P Tank V Electromagnetic LN Valve Security Shut-off Valve Agata week, Cologne, 0. March -. April 009
7 Structure of the Autofill System Tº,, LN PROFIBUS Crate HV Outflow Pt00 PROFIBUS Compartment Digital In/Out Board Analogue Input Boards Pt00 Input Boards Digital Input Board Tank Digital Output Digital Input GUI Watchdog Siemens SIMATIC PLC Digital Signals In/Out - Channel Valve Control Crate Master Card Valve Control Cards Dry Contacts Output Power Card Connector Panel PS Card Power Switch Filling Valves Digital Output Dry Contacts Output Connector Digital Input Auto/Manual/Local Mode Switch Dry Contacts Alert BSD... Agata week, Cologne, 0. March -. April 009
8 Status of the development PROFIBUS crate is ready and in operation. Minor changes needed Valve Control crate is ready, to be commissioned beginning of April 009 at LNL Similar system is in operation at GSI for test and development purposep Valve Control Card Agata week, Cologne, 0. March -. April 009
9 Thank you Agata week, Cologne, 0. March -. April 009
Fire and Gas Monitoring Panel ST7-HV
Fire and Gas Monitoring Panel ST7-HV INTRODUCTION TO THE ST7-HV SYSTEM The ST7-HV system is a programmable PLC suitable for safety and security installations with a high technological and economic content
More informationInstalling the assembly SIMATIC. Installing the assembly. Overview 1. Installing the assembly. Getting Started A5E
Overview 1 2 SIMATIC Getting Started 03/2013 A5E03973659-01 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as
More informationRS485 MODBUS Module 8AI
Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationMonitoring Solutions
GSM Systems Monitor: Temperature, Humidity, Power, Water, Smoke, Carbon Monoxide and More September 2016 Table of Contents GSM Systems... 3 Argon 100 GSM... 3 Ares 12 & 14 GSM... 4 Poseidon2 4002... 5
More informationDew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510
Dew point monitoring DS 400 for stationary dew point monitoring of refrigeration or desiccant driers. The touch screen graphic display enables an intuitive operation and shows the progress of the measured
More informationDesign specifications and test of the HMPID s control system prototype in the ALICE experiment
Design specifications and test of the HMPID s control system prototype in the ALICE experiment Enzo CARRONE Enzo.Carrone@cern.ch HMPID Control System Design Implementation and tests Conclusions HMPID,
More informationEL-OEM-3 OEM Packaged Voltage Data Logger
FEATURES PCB Mounted (2.54mm pitch, header sockets) 0 to 2.4V d.c. Measurement Range Logging Rates between 1s and 12hr Stores 64,000 readings USB interface for set-up and data download (USB connector not
More informationHOBO U14 Data Logger User Manual
HOBO U14 Data Logger User Manual The U family of data loggers offers reliability and convenient monitoring for applications that require higher accuracy, better resolution, more memory, or USB connectivity
More informationOVEN INDUSTRIES, INC.
OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and
More informationwith internal sensor (channel 1) with an external sensor (channel 2) A-Editor software, Professional AK20 version (not for version AK4)
Examples of use Example Creating an SMS-based alarm with confirmation A project file must first be created using the A-Editor software. This project file is then stored in the alarm modem. The alarm modem
More informationMULTIPERFORMER ISO ISOBUS. ELECTRONIC EQUIPMENT for LIQUID and MICROGRANUAL PRODUCT DISTRIBUTION CONTROL USER INSTRUCTION MANUAL
MULTIPERFORMER ISO 11783 - ISOBUS ELECTRONIC EQUIPMENT for LIQUID and MICROGRANUAL PRODUCT DISTRIBUTION CONTROL USER INSTRUCTION MANUAL COD. 11781101 EN - REV. 01 software ver. 1.0 2014 MULTIPERFORMER
More informationVery High Sensitivity Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities.
SMD601 for Law Enforcement and Correctional Facilities NEW GENERATION Most Sensitive WTMD, fully compliant with the NIJ-0601.02 Standard Very Accurate Pinpointing of individual and multiple metal targets
More informationLMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification
LMV52 Control Product Description February 3, 2017 The LMV52 is a microprocessor-based burner management system with matching system components for the control and supervision of forced draft burners.
More informationSmoke Detector and Siren. Manual
Smoke Detector and Siren Manual 004001 Smoke Detector and Siren Manual Quick Start... 2 Product Description... 2 Installation Guidelines... 3 Behavior within the Z-Wave Network... 3 Operating the Device...
More informationBionics Instrument. Alarm Handling. Gas Alarm Systems
Gas Alarm Systems Controllers and PLC based systems Alarm Handling Complete control at the right time and place Every gas detector consist of a gas sensor and a signal transmitter. In case of a gas leak,
More informationTECHNICAL BULLETIN [ 1/9 ]
TECHNICAL BULLETIN [ 1/9 ] [Title] Production Discontinuation of the PLC MELSEC-F Series Temperature Control Block FX2N-2LC [Date of Issue] April 2017 [Relevant Models] MELSEC-F series FX2N-2LC Thanks
More informationDew point set DS 400
set DS 400 Dew point set DS 400 for stationary dew point monitoring of refrigeration or adsorption dryers. The touch screen graphic display enables an intuitive operation and shows the progress of the
More informationFire Control Panel FS5100
Fire Control Panel FS5100 INSTRUCTION MANUAL Revision 6/02.11 Contents 1. Introduction... 5 2. Terminology... 5 3. Function... 7 4. Technical data... 7 4.1. Modules... 7 4.1.1. Type of modules... 7 4.1.2.
More information165 Supplements and Amendments to the MSR 165 User Manual
Supplements and Amendments to the MSR User Manual Open the MSR145 user manual on the enclosed CD and read it through. Then read the supplements set out below. Page references to the MSR145 user manual
More informationPMD2 Plus. Enhanced Walk-Through Multi-Zone Metal Detector. new. Threat Detection through Electromagnetics. generation
PMD2 Plus Enhanced Walk-Through Multi-Zone Metal Detector new generation Superior Detection and Throughput Very High Discrimination Compliant with the strictest Security Standards Column and Panel versions
More informationINSTRUCTION MANUAL. Software Revision Card 3.2 DOCUMENT SES-KS E REV. 3
2402 COMBUSTIBLE GAS CARD 2 CHANNELS 2404 TOXIC GAS CARD 2 CHANNELS 2407 OXYGEN GAS CARD 2 CHANNELS INSTRUCTION MANUAL Software Revision Card 3.2 DOCUMENT SES-KS-2402-04-07-E REV. 3 2402 2404 2407-2 CHANNELS
More informationDevelopment of a measurement and control system for a 10 K refrigerator based on Siemens PLC S7-300
Development of a measurement and control system for a 0 kw@0 K refrigerator based on Siemens PLC S7-300 J Li,, L Q Liu, T Liu 3, X D Xu, B Dong, W H Lu, W Pan, J H Wu and L Y Xiong Key Laboratory of Cryogenics,
More informationFrequently asked questions: Intelligent Transmitter Series
Frequently asked questions: Intelligent Transmitter Series The Wilcoxon family of Intelligent Transmitters, relay alarms, and communication modules can be used to implement low-cost online vibration monitoring
More informationFire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63
Fire Extinguishing Control Panel FS5200Е INSTRUCTION MANUAL Revision 8/01.17 Instruction Manual Page 1 1. 2. 3. 4. 4.1. 4.2. 4.2.1. 4.2.2. 4.2.3. 4.2.4. 4.2.5. 4.2.6. 4.2.7. 4.2.8. 4.2.9. 4.2.10. 4.2.11.
More informationTechnical Specification PILATUS 100K Detector System
Technical Specification PILATUS 100K Detector System Vesion 1.0 Table of Contents 1 Document History...4 1.1 Changes...4 2 Technical specifications...5 2.1 Technical data...5 2.2 Normal operation...6 2.3
More informationLineGuard 2300 Program User Manual (FloBoss 107)
Form A6251 Part Number D301346X012 November 2012 LineGuard 2300 Program User Manual (FloBoss 107) Remote Automation Solutions Revision Tracking Sheet November 2012 This manual may be revised periodically
More informationMultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price
MultiMeter 44 Transmitter-regulator with 1, 2 or 3 channels MultiMeter 44 is a modular meter that can be configured with one, two or three channels. It can be delivered with only one measuring channel,
More informationSMD601 Plus. The most Sensitive Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities. Threat Detection through Electromagnetics
The most Sensitive Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities new reference standard in sensitivity Most Sensitive WTMD, fully compliant with the NIJ-0601.02 and NIJ-0601.03
More informationREAD ME FIRST DIY WIRELESS ALERT. Add-on Alert Sensor. For Swann Wireless Alert systems. Instruction Manual
READ ME FIRST DIY WIRELESS ALERT Add-on Alert Sensor For Swann Wireless Alert systems EN Instruction Manual 2 About this Manual The content in this manual is for information purposes only and is subject
More informationFI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface
INSTRUCTION MANUAL FI6000 Fire Alarm Interface Thank you for choosing another quality product from Amperes Electronics. FI6000 is a phase evacuation controller which can be integrated with various Amperes
More informationBatt-Safe Battery String Monitoring System
Batt-Safe Battery String Monitoring System Technical White Paper October 2010 Introduction Battery monitoring systems are categorized as either cell monitors or string monitors. Battery cell monitors provide
More informationSIMATIC IPC DiagBase SIMATIC. Industrial PC SIMATIC IPC DiagBase. Introduction. DIAG software components. Quick-Start Guide
Introduction 1 DIAG software components 2 SIMATIC Industrial PC Operating Manual Quick-Start Guide 3 Hardware and software requirements 4 Installing and removing the software 5 Description of the Management
More informationHEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new
More informationSITRANS T temperature transmitters A broad product family for every application. sitrans
SITRANS T temperature transmitters A broad product family for every application sitrans The SITRANS T family High-precision, intrinsically safe, and available for a wide variety of sensors Whether you
More informationStatus of AGATA detectors. deliveries customer acceptance tests neutron damage maintenance, annealing,
Status of AGATA detectors deliveries customer acceptance tests neutron damage maintenance, annealing, AGATA week @ Lyon, 22-26 November, 2010 AGATA crystals - overview 21 detectors were delivered: A001,A002,A003,A004,A005,A006,A007,A008
More informationSIMATIC IPC DiagBase SIMATIC. Industrial PC. Introduction. DIAG software components. Quick-Start Guide. Hardware and software requirements
Introduction 1 DIAG software components 2 SIMATIC Industrial PC Operating Manual Quick-Start Guide 3 Hardware and software requirements 4 Installing and removing the software 5 Description of the Management
More informationOvation Alarm Management System
Ovation Alarm Management System Features Multiple types of fully configurable, easy-tounderstand alarm displays Convenient access to past alarms, returns and state changes Simplified ability to acknowledge,
More informationTemperature Data Logging
. Temperature Data Logging Making the right choice with a Data Acquisition System There are many ways to make temperature measurements. The simplest method is to insert a temperature probe into a device
More informationSMS GSM Alarm Messenger
SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up
More informationFCD-wire Contents. List of Figures
FCD-wire Contents FCD-X21 Configuration 1 Introduction... 1 2 Opening the FCD Application... 1 3 FCD Window... 2 4 FCD LEDs... 3 5 Configuration Operations... 4 FCD Info...4 FCD System Info...5 FCD Interface
More informationPMD2 Plus series. Enhanced Walk-Through Metal Detectors. NEW. Threat Detection through Electromagnetics GENERATION
NEW GENERATION Superior Detection and Throughput Certified to the strictest Security Standards Column and Panel versions Unmatched Reliability & No Calibration and Maintenance required Rapid Installation
More information4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head
4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head NET DRAFT version 2.1-2008 Pag. 1 4-20mA Cyber - DRAFT version 2.1-2008 Pag.
More informationLIBERO PDF Logger for Cryogenic Container Monitoring
LIBERO PDF Logger for Cryogenic Container Monitoring we prove it. www.elpro.com Buchs, 22.MAY.2014 Page 1 LIBERO Cryogenic Monitoring Solution www.elpro.com Buchs, 22.MAY.2014 Page 2 LIBERO Cryogenic Monitoring
More informationHI-PE HIGH PERFORMANCE WALK-THROUGH MULTI-ZONE METAL DETECTOR. Threat Detection through Electromagnetics
HIGH PERFORMANCE WALK-THROUGH MULTI-ZONE METAL DETECTOR Accurate Detection of magnetic, non-magnetic and mixed-alloy metal weapons High Discrimination and Throughput Exceptional Immunity to environmental
More informationMÖBIUS Recycler. Condensing Liquid Nitrogen HPGe Detector Cooling System
Recycler Condensing Liquid Nitrogen HPGe Detector Cooling System All the advantages of Liquid Nitrogen cooling without the need for frequent refilling. Introduction The ORTEC Möbius Recycler technology
More informationHome Doorway Alert Kit
READ ME FIRST DIY WIRELESS ALERT Home Doorway Alert Kit EN Instruction Manual 2 About this Manual The content in this manual is for information purposes only and is subject to change without notice. While
More informationVery High Sensitivity Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities.
for Law Enforcement and Correctional Facilities new generation Most Sensitive WTMD, fully compliant with the NIJ-0601.02 Standard Very Accurate Pinpointing of individual and multiple metal targets Integrated
More informationTable of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11
Table of Contents 1. OVERVIEW... 3 2. SYSTEM LAYOUT... 4 3. SPECIFICATIONS... 8 3.1 SYSTEM COMPONENTS...9 3.2 PLC INPUTS AND OUTPUTS...9 3.3 FUNCTION KEYS...10 3.4 DEFAULT SET POINTS AND TIMERS...10 4.
More informationTypical applications include the vibration detector. Detection of vibrations and shocks
Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power supply systems
More informationOutdoor Temperature Sensor
Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power supply systems
More informationLaboratory Deep Freeze Storage Cabinet TC 230 Air circulated
External Dimensions: B = 600 mm D = 650 mm (at -30 C/-40 C: 760 mm) H = 1640 mm (at -30 C/-40 C: 1720mm) Internal Dimensions: B = 500 mm D = 500 mm H = 890 mm Capacity: 300 l Temperaturerange: Optional:
More informationEnd To End Optical Beam Smoke Detector. Additional Information
End To End Optical Beam Smoke Detector Additional Information EN 1. Multiple Zone Wiring When using more than one System Controller on a single zone of a conventional Fire Control Panel (FCP), it is important
More informationEi600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren
Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren Quick Start This device is a combination of a Z-Wave sensor (smoke sensor) and a Z-Wave actuator. Pressing the button 'Inclusion Button' for one
More informationLaboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)
External Dimensions: B = 1500 mm D = 820 mm H = 2100 mm Inside Dimension: Room 1 B = 600 mm D = 670 mm H = 1330 mm Room 2 B = 600 mm D = 670 mm H = 1330 mm Capacity: 1500 l Temperature range: Room 1 2
More informationSIMATIC. Industrial PC SIMATIC IPC DiagBase V Introduction. SIMATIC IPC DiagBase software components. Quick-Start Guide
Introduction 1 SIMATIC IPC DiagBase software components 2 SIMATIC Industrial PC Operating Manual Quick-Start Guide 3 Hardware and software requirements 4 Installing and removing the software 5 Displaying
More informationMedical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345
External Dimensions: B = 530 mm D = 640 mm H = 1600 mm Inside Dimension: Useful space on top Useful space at the bottom B = 450 mm B = 450 mm D = 535 mm D = 535 mm H = 530 mm H = 530 mm Capacity: 280 l
More informationDIGITAL TEMPERATURE RELAY TR-100
LTD Research-and-Manufacture Company DIGITAL TEMPERATURE RELAY USER S MANUAL www.novatek-electro.com - 2 - Service manual is intended for getting acquaints with hardware, operation principals, modes of
More informationCompressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture
meas. according to ISO 8573 Residual oil content - particles - moisture DS 500 - the intelligent chart recorder of the next generation. The centerpiece of compressed air quality measurement is the chart
More informationCombined CAN Sensor Unit Temperature, Humidity and Smoke
Combined CAN Sensor Unit Temperature, Humidity and Smoke Didactum`s IP-based monitoring devices have many uses: Monitoring of wiring closets and server room environments Remote monitoring of technical
More informationSITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions
Introduction 1 General safety instructions 2 SITRANS Temperature transmitter Device-specific safety instructions 3 Appendix List of Abbreviations/Acronyms A B Product Information Supplement to Operating
More informationMÖBIUS Recycler Condensing Liquid Nitrogen HPGe Detector Cooling System
Recycler Condensing Liquid Nitrogen HPGe Detector Cooling System All the advantages of Liquid Nitrogen cooling without the need for frequent refilling. The ORTEC Möbius Recycler technology provides tried
More informationNetbiter Tank Sensor
For Netbiter Tank Sensor HMS Industrial Networks AB Post address: Box 4126 300 04 Halmstad SWEDEN Visitor s address: Stationsgatan 37 302 45 Halmstad SWEDEN Telephone: + 46 35 17 29 00 Fax: + 46 35 17
More informationParadox Integration Module Settings Guide
Paradox Integration Module Settings Guide List of Terms used in Paradox Integration Module Settings Guide............. 3 Introduction into Paradox Integration Module Settings Guide............... 4 Configuration
More informationTemperature Measurement
/2 Transmitters for mounting in sensor head /6 SITRANS TH100 two-wire system (Pt100) /10 SITRANS TH200 two-wire system universal /17 SITRANS TH00 two-wire system /24 SITRANS TH400 fieldbus transmitter
More informationManage Alarms. Before You Begin CHAPTER
CHAPTER 9 Manage Alarms This chapter contains the procedures for viewing and managing the alarms and conditions on a Cisco ONS 15454 SDH. Cisco Transport Controller (CTC) detects and reports SDH alarms
More informationSiemens Drives & PLCs
Introduction 1 DIAG software components 2 SIMATIC Industrial PC Operating Manual Quick-Start Guide 3 Hardware and software requirements 4 Installing and removing the software 5 Description of the Management
More informationPlasma Freezer with air circulation TC 516 acc. to DIN 58375
These blood plasma storage cabinets are designed for DIN - compliant storage of already frozen blood plasma bags. External Dimensions: B = 600 mm D = 780 mm H = 2000 mm Internal Dimensions: B = 500 mm
More informationSpecifications Cooling tower series KAHV - hybrid recooler for closed circuit cooling with axial fans comprising:
Specifications Cooling tower series KAHV - hybrid recooler for closed circuit cooling with axial fans comprising: Housing The housing consists of a welded, self-supporting, stainless steel framing structure
More informationRS Pro Infrared Temperature Sensor
Instruction Manual RS Pro Infrared Temperature Sensor Stock Number: 161-8103 Introduction The RS Pro Infrared Temperature Sensor is a device for measuring the temperature of the surface of a solid or liquid
More informationProduct Specification
Product Specification M7300CD Variable Gain EDFA, 17 dbm OP, 15-30 db Gain PN: FOA-M7300CD-EVG1C-AA002 Document No.: 1213704 Revision: A00 Date: 01-Apr-14 Customer: General Product Features Variable Gain
More informationHI-PE Plus ENHANCED WALK-THROUGH MULTI-ZONE METAL DETECTOR. Threat Detection through Electromagnetics. Applications.
HI-PE Plus ENHANCED WALK-THROUGH MULTI-ZONE METAL DETECTOR EU Certified Accurate Detection of magnetic, non-magnetic and mixed-alloy metal weapons 60 localization zones: 20 vertical 3 lateral High Discrimination
More informationInstallation Guide for inbiox60 Series Access Control Panel
Installation Guide for inbiox60 Series Access Control Panel Version: 1.0 Date: April, 2011 About This Manual This manual is a guide to installation and connection of the inbiox60 series access control
More informationVESDAnet Interface Card Product Guide. Document Number: 10672_05 Part Number: 30071
VESDAnet Interface Card Product Guide Document Number: 10672_05 Part Number: 30071 Xtralis VESDA VESDAnet Interface Card Product Guide Intellectual Property and Copyright This document includes registered
More informationREAD ME FIRST DIY WIRELESS ALERT. Driveway Alert Kit. Instruction Manual
READ ME FIRST DIY WIRELESS ALERT Driveway Alert Kit EN Instruction Manual 2 About this Manual The content in this manual is for information purposes only and is subject to change without notice. While
More informationExternal Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C
External Dimensions: B = 750 mm D = 700 mm H = 2100 mm Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm Capacity: 600 l Temperaturerange: 2 C to 20 C Housing galvanized sheet steel with high quality
More informationHERCULES 6 GRAPHICS SYSTEM
HERCULES 6 GRAPHICS SYSTEM USER MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273 Web: www.protec.co.uk
More informationDSP EC Pro. Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems
Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems DSPEC Pro: Advancing the Art of Digital Gamma-Ray Spectroscopy The immense versatility of DSPEC Pro, brought about by the number of unique
More informationVisit us at testo 835 Infrared and contact thermometer
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com testo 835 Infrared and contact thermometer Instruction manual 1. General information
More informationRESET + Password Enter (During Auto Speed Procedure) Maintenance Timeout or after TEST + RESET + DISABLE (No Need for Device to Initialize)
FAAST LT FIRE ALARM ASPIRATION SENSING TECHNOLOGY ADVANCED SET-UP AND CONTROL GUIDE CONTENTS Introduction....1 The FAAST LT Functional State Diagram....1 Password Procedure (to enter Maintenance Mode)
More informationSentry G3 Machinery Protection Monitor
TECHNICAL INFORMATION Sentry G3 Machinery Protection Monitor CONDITION MONITORING SOLUTIONS The Sentry G3 Machinery Protection Monitor is a high performance signal conditioning unit; providing a universal
More informationA36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS
SCADA INTERFACE INSTRUCTIONS - OPTION 21S - FOR A36D/TPSD SYSTEMS with option 500 and 550. A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE OPTION 21S INSTRUCTIONS This manual is valid for A36D/TPSD Chargers
More informationTurn the power off, then back on. Reduce the number of registered blocks to 32. Check the cable connection.
Program or Setting Alarms (PS alarms) No LED Display Description Countermeasure 000 A parameter that requires power-down has been specified Turn the power off, then back on. 011 The specified feedrate
More informationDescription of the application programme for KNX occupancy detectors version 3.1
Contents 1. General...1 1.1 Basics for the KNX/EIB BUS...1 1.2 Application versions...1 1.2 Application versions Switchgear application Version 3.1: BEG_SWI_HKL_V3.1 Part numbers: 1.3 Symbols used...1
More informationAlgo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM
Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS) USER MANUAL Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT, ENGLAND +44 (0) 1282 717171 www.protec.co.uk
More informationCAN unit for Analog Sensors
CAN unit for Analog Sensors Didactum`s Monitoring Systems have many uses: Monitoring of wring closets and server room environments Remote monitoring of technical rooms in branch offices Monitoring of power
More informationMarlin Filament Monitoring October 2014
Why is Filament Monitoring Useful? Marlin Filament Monitoring October 2014 There are a number of filament monitors and filament break detectors available which will generate an alarm if the filament runs
More informationZM2 OPERATING AND MAINTENANCE INSTRUCTIONS
ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS CONTENTS 1. System Overview 2. User responsibilities 3. First Line controls and indications 3.1 Logging on to the fire alarm system 3.2 Checking system status
More informationATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.
ATSTORM v2 ATSTORM v2 is a storm detector that measures the environmental electric field. It is fully automatic, without mobile parts, robust and highly reliable The storm detector ATSTORM v2 basic configuration
More informationRefrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA
Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA 99336 www.jmcvr.com 1-509-586-9893 Table of Contents TABLE OF FIGURES...1 OVERVIEW OF THE HRC CAPABILITIES...2 INSTALLATION AND
More informationIntegration Test Plan
Integration Test Plan Terminus Security Prepared by: Kai Chan Stephen Krenzel John O Meara Version: 1.0 1 Contents 1 Introduction 3 1.1 Purpose.................................. 3 1.2 Scope...................................
More informationMONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products
MONITORING Measurement Sensors Dry contacts Logging Analysis, Alarms Various products XML/HTTP SNMP, E-mail GPRS/SMS Reports Graphs, Excel Alarms www.hw-group.com Measurement, Sensors Temperature Humidity
More informationBasics of Safety Applications
Basics of Safety Applications Unrestricted Siemens 2016 usa.siemens.com/controls Why Safety Technology? Protection of People Environment Page 2 Safety Process Chain The necessary steps towards a safe machine
More informationSiemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation
Sinteso Cerberus PRO FDA241, FDA221 ASD Aspirating smoke detector Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation Patented technology Early
More informationLAUNDRY MONITORING SYSTEM Model # LIM-64S
LAUNDRY MONITORING SYSTEM FEATURES: HIGH SENSITIVITY EVEN TO LOW ENERGY GAMMAS 6 EACH 8 X 8 SCINTILLATORS ABOVE 4 EACH 2 X 12 NaI(Tl) BELOW AUTOMATIC CONVEYOR FOR LAUNDRY AUTOMATICALLY SEPARATES CLOTHES
More informationSentry G3 Machinery Protection Monitor
TECHNICAL INFORMATION Sentry G3 Machinery Protection Monitor CONDITION MONITORING SOLUTIONS The Sentry G3 Machinery Protection Monitor is a high performance signal conditioning unit; providing a universal
More informationRTO. User guide 05/
RTO User guide Version: RT0 M&S (master & slave) Characteristics: Constant lighting, temperature regulation with a low inertia heating system. Building opening hour scheduler and presence detection. 05/2013
More informationThe most Sensitive Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities.
The most Sensitive Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities new reference standard in sensitivity Most Sensitive WTMD, fully compliant with the NIJ-0601.02 and NIJ-0601.03
More informationReal-time Air Monitoring System
for the Real-time Air Monitoring System Project Team: Marvin Lee Sam To Tessa Ryan Rouzbeh Roshanravan Contact Person: Rouzbeh Roshanravan rra19@sfu.ca Submitted to: Dr. Andrew Rawicz ENSC 440 Steve Whitmore
More informationBasics of Safety Applications
Basics of Safety Applications Unrestricted Siemens 2016 usa.siemens.com/controls DISCLAIMER/ TERMS OF USE: THE INFORMATION PROVIDED HEREIN IS PROVIDED AS A GENERAL REFERENCE REGARDING THE USE OF THE APPLICABLE
More informationCRIOTEL. The complete solution for local and remote monitoring of cryogenic tanks under pressure
CRIOTEL The complete solution for local and remote monitoring of cryogenic tanks under pressure AMBRA SISTEMI company, operating for over 20 years in electronic devices production, specifically for the
More information