TECHNICAL SPECIFICATION ABC DRY POWDER STORED PRESSURE TYPE FIRE EXTINGUISHERS
|
|
- Bertina Brooks
- 5 years ago
- Views:
Transcription
1 TECHNICAL SPECIFICATION ABC DRY POWDER STORED PRESSURE TYPE FIRE EXTINGUISHERS Capacity (In Kg.) 500 gms IS Specification Jet Range (In Mtrs.) Discharge Time (In Sec.) Min. Discharge Qty. 85% 85% 85% 85% 85% Seal of Approval ISI ISI ISI ISI ISI Hydraulic Test Pressure of Cylinder (Kg./Cm2) Outlet Direct Nozzle Direct Nozzle Direct Nozzle Discharge Discharge Hose & Nozzle Hose & Nozzle
2 TECHNICAL SPECIFICATION CARBON DIOXIDE TYPE FIRE EXTINGUISHERS Capacity (In Kg.) Water Capacity (ltr.) /5 6.8/7 10/12 14/ % 98% 98% 98% 98% 98% Seal of Approval ISI ISI ISI ISI ISI ISI Hydraulic Test Pressure of Cylinder (Kg./Cm2) IS Specification Jet Range (In Mtrs.) Discharge Time (In Sec.) Min. Discharge Qty. Working Pressue (Kg./Cm2)
3 TECHNICAL SPECIFICATION DRY CHEMICAL POWDER TYPE FIRE EXTINGUISHERS % 90% 85% 85% 85% Seal of Approval ISI ISI ISI ISI ISI Hydraulic Test Pressure of Cylinder (Kg./Cm2) Capacity (In Kg.) IS Specification Jet Range (In Mtrs.) Discharge Time (In Sec.) Min. Discharge Qty.
4 Product Specifications TECHNICAL SPECIFICATION Capacity (In Ltr.) WATER CO2 WATER CO2 WATER CO2 STORED PRESSURE % 90% 95% Seal of Approval ISI ISI - Hydraulic Test Pressure of Cylinder (Kg./Cm2) IS Specification Jet Range (In Mtrs.) Discharge Time (In Sec.) Min. Discharge Qty. Trolley Fire Extinguishers:Co2 Water Type 50 ltr.
5
6
7
8
9
10
11
12
13
14 Automatic Modular ABC Fire Extinguishers Available in 5/10/15/20 kgs.
15 Trolley Fire Extinguishers Mechanical Foam Type 50 ltr.
16 STOP FIRE WITH FIREBELL'S FIREBALL It is an extingushing device in the shape of a ball and tested by various govt. department Globally used to extingnish fire contain mono ammoniom phophatic and can be used in all types of fire. Automatic Fire Extinguisher Our range of Fire Alarm and Extinguisher Systems are conventional & addressable systems. Fire Panel Smoke Fire Heat Manual Response Glow Sprinkler FM 200 Extinguisher Cylinders / Accessories / Detectors Panels Detectors Call Points Indicators Signs systems Gas System Sensors
17 Automatic Fire Extinguisher The most damaging fires usually occur in unoccupied areas or at times when no person is around-night time and holidays. Moreover in a big plant, it is not possible to keep an eye at all places all the time. Therefore, an automatic installation is the only answer to round the clock fire protection. Moreover, modular system is simple to erect without involving costly and unsightly pipe work. Automatic fire extinguishers can be provided with powder and gas based extinguishing agents. Auto Fire Extinguishing System C02/ FM-200 Auto fire extinguishing system is the best choice for ensuring fire safety of important places like computer center, library, power distribution room, telecommunication and archives centre. This system is easy to operate and maintain. aesthetics of places like hotels, banquet halls, supermarkets, offices etc. In case of fire, the sprinkler s get burst and CO2 / FM-200 floods the room to immediately extinguish the fires. Fire Doors
18 We offer to our clients a wide range of fire doors that are widely used in homes and offices to maximise safety in the event of fire. Our doors not only provide protection but is good in appearance also. Our fire doors are successfully tested and approced by CBRI, Roorkee & quality making centre, Department of Industries, Govt.of Haryana for ensuring the best quality. Our Fire Doors are governed by following specifications: BS476 Part 20 & 22 - Fire Test on Building Materials and Structures. ISO Fire Resistance Test Elements of Building Constructions. ISO Fire Resistance Test on Doors & Shutter Assemblies. IS 3614 Part-II Metallic and non metallic fire check doors Resistance Test and performance criteria. IS 3809: Fire Resistance test on structures. Our fire-rated doors are available in: I. Wood: We deliver 60 and 120 wooden fire doors that are tested under positive nad negative pressure to ensure safety II. Steel: Adtech fire-rated steel doors combine the strength of steel with varied positive fire ratings nad have upto 60 and 120 minutes protection. It is available in different models and is offerd at competitive rates. We offer Fire Retardant Coating that is an interior paint which is recommended for use as an overcoat in areas where maximum durability and fire rating is required. Coating for Wood: The burning characteristics of wooden products can be reduced by applying specially formulated coatings to wood surfaces. These coatings can be applied with the help of brush and rollers. Specifications of Fire Resistant Coating: We also offer Fire Resistant coating of approved brand to provide Class I surface spread of flame and other properties confirming to BS:476 part- 6 & 7 and IS in desired shade including cleaning and preparation of surface complete as per manufacture specifications. We also specialize in manufacturing & marketing of METALLIC and NON- METALLIC FIRE DOORS upto 120 minutes fire rating. Owing to our long industrial experience, we are capable of designing and producing a complete range of fire safety products. The main aim of our company is to provide protection to offices, commercial buildings, malls, cinema halls and hospitals against fire. Backed by an efficient team of professionals and the state-of-the-art manufacturing unit. Fire Rated Door Closer
19 We have come out with commercial Fire Rated door closer that is light in weight and has an efficient mechanism. It has been designed for use on residential or light commercial interior hollow core wooden doors i.e. electrical cupboards, storeroom and office doors. Our Fire rated door closer is available as either a strength 3 or 4 closer to suit the most popular range of door sizes. Door closing is hydraulically controlled, with regulators to give the desired speed of closing. Features: Finish: Sprayed Silver Regulating Controls: It has independent regulators to control: - Closing Speed: Adjustment to control closing swing of door, from approximately 180 to 15. -Latch Speed: Separate adjustment to accelerate or decelerate the door from 15 to 0 to either overcome stubborn latch bolts, or cushion the door into the frame. - Material: It is constructed with high quality components, with a pressure die cast aluminium body, and a steel rack and pinion. Photo Luminescent Glow Signs We offer to our clients photo luminescent glow signs that play a vital role in risk prone and panic situation and are specilly desisgned for emergency exit, escape routes, fire and mandatory warnings and prohibition. Glow signs play a vital role in risks prone & panic situation, It reduces confusion & fear in case of emergency. We have Specially designed glow signs for emergency exit, escape routes, fire & mandatory warnings & prohibition. Made using latest technology our product is reasonable and are offered with customized specifications. Panic / Exit Device We have come out with panic/exit device that do an excellent job of both securing a buliding and providing a safe way out at the time of any emergency. Panic bars are installed on exit doors for extra security and safe passage for crowd in panic. We have a range of push bar devices that is available in different models. Enhanced security can be provided in Exit doors by installing Panic bars with alarm. This exit device is highly efficient and is available at industry leading rates. Fire Rated Clear & Wired Glass Avail from us awide range of fire rated clear & wired glass that creates a barrier to smoke and flames.this glass is tested in the conditions where the temperature exceeds 1,000 F. This glass has the capacity to restrict the expansion of the fire and is used in corridors, lobbies, stairwells of a building that could serve as an escape route during a fire.the Wired glass offered is from Pilkington UK and Central Glass Co. We also offer clear fire rated glass from Saint Gobbin Glass. It is very important to have the correct system of framing the Fire Rated Glasses.The complete system together i.e.glass with intumescent seal/gasket decides the performance of Fire Rating of Glazed partitions and Glazed doors. Fire Protection System (FM 200 System)
20 We 'Bell Fire' engineering group design, engineer and install worlds most accepted protection system to facilities containing valuable corporate assets from people and processes to equipment and software. FM 200 discharges a gas with in 10 seconds after receiving an actuation signal and reaching into all areas of the protected facility. FM200 suppresses fire by flooding the protected area with a 7% concentrate of FM 200, instead of inserting the entire area. FM 200 actively attacks the fire itself, soaking up heat like a sponge soaks up liquid and breaking down the fire's molecular structure and leaving no residue to damage sensitive equipment or require costly cleanup. This rapid action catches a fire in its incipient stages before it has an opportunity to grow or cause significant damage and enables you to get back to normal business operations faster after a fire. FM 200, is non-toxic when used in accordance with NFPA standard The most viable alternative to We 'Bell Fire' engineering group design, engineer and install worlds most accepted protection system to facilities containing valuable corporate assets from people and processes to equipment and software. FM 200 discharges a gas with in 10 seconds after receiving an actuation signal and reaching into all areas of the protected facility. FM200 suppresses fire by flooding the protected area with a 7% concentrate of FM 200, instead of inserting the entire area. FM 200 actively attacks the fire itself, soaking up heat like a sponge soaks up liquid and breaking down the fire's molecular structure and leaving no residue to damage sensitive equipment or require costly cleanup. This rapid action catches a fire in its incipient stages before it has an opportunity to grow or cause significant damage and enables you to get back to normal business operations faster after a fire. FM 200, is non-toxic when used in accordance with NFPA standard The most viable alternative to Halon 1301, FM 200 causes no breathing problems for people and won't obscure vision in an emergency situation, has zero Ozone Depletion Potential (ODP), a low atmospheric lifetime (31 42 years) and is listed by the Environmental Protection Agency with no usage restrictions. The CO2 system provided to clients have got CO2 gas that has a high expansion ratio, which leads to rapid discharge and also allow three dimensional penetration of the entire hazard area in the quickest manner. Advantages of CO2 system: Fast in action. Non damaging nature towards the equipment. Non conducting. Effectively stops the difficult fire situation. Applications: Transformers Power Generators Ships Holds Machinery Spaces Electrical Equipment - Alternators Chemical Equipment- Flammable liquids Chemical Works & Stores Switch Rooms Electric Movers Solvent Stores Dip Tanks
21 FIRE ALARM SYSTEMS Wind tone sirens manufactured at our end is another range of superior fire safety product we have been offering to clients since a long time. These sirens are used to make people cautious of suddenly emerged fire and is a signal of evacuating the affected place. These sirens have a unique feature of producing a tone that stands up to wind fade and tree cover. The products have got a resistivity towards corrosion as well as highly durable nature. The Purpose of a Fire Detection and Alarm System is to detect the Fire and its location at the earliest practicable moment and to give an Alarm as well as appropriate action e.g. evacuation of occupants, summoning the Fire Fighting Organization, triggering exhaust fan, extinguishing processes, etc. An Alarm System may be activated by automatic detection devices such as Smoke/Heat Detectors or by manual operation of manual call points. The range of fire hose reel we offer to clients, provide a controlled supply of water in case of a potential fire risk. The standard fire hose reel has got a length of 36 meters and a diameter of 19mm. These products have got control nozzles attached at the end of the hose that helps the operator in controlling the flow and direction of water. A unique ball valve shut off device, plastic or solid brass hose reel nozzle and mounting bracket are some of the devices attached with the fire hose reel. We are a renowned name involved in the manufacturing of superior quality fire fighting appliances, which are offered to a large number of clients across global markets. These appliances are made from best available raw materials procured from trusted suppliers. Our team of experts conduct stringent quality checks on each manufactured product to ensure their superior quality and better functioning. High Beam with Exit, Pictograph & Glow Sign Boards Powerful Halogen beam searchlight & Exit Signage housed in powder coated MS box provision for wall mounting complete with SMF battery. All purpose Pictographs are fitted with CFL Tube housed in wooden or metallic cabinets to give continuous working on A.C. mains as well as Battery pack. All emergency features as in Super Light Available in CFL, LED,FI Tube and custom designed in various size & designs. We manufacture glow sign boards which are an effective medium to convey the desired message to the masses. These sign boards are tough and durable in nature. They also do not require and nuts and bolts for fabrication and are also very sleek and modern in design. These sign boards are also rust proof and perfect for outdoor promotional purposes. Fire Alarms Addressable Fire Detection Devices It is an automatic fire detection & alarm system that consists of fire detectors & manual call points positioned in Zones/ loop through out a building. These are wired to control & indicating equipment which shows the location of alarm call, & actuates audible alarm sounders. Designed to withstand every climatic conditions, these devices are widely used in following area of applications: Industrial/ Non Industrial Buildings
22 Institutional Buildings Residential Apartments Hotel & Hospitals All Industries Mall & Multi Storied Complexes Offices & Control Rooms Addressable Fire Detection & Alarm System This is also an an automatic fire detection & alarm system consists of fire detectors & manual call points positioned in Zones/ loop through out a building. These are wired to control & indicating equipment which shows the location of alarm call, & actuates audible alarm sounders. Some of the areas where it is widely used are : Industrial/ Non Industrial Buildings Institutional Buildings Residential Apartments Hotel & Hospitals All Industries Mall & Multi Storied Complexes Offices & Control Rooms CO2 Gas Flooding Systems Co2 at atmospheric pressure is a colorless, odorless and electrically Non Conductive inert gas, It has high expansion ratio which facilities rapid discharge and allows three dimensional quick penetration in the entire hazard area. Made from premium quality components, this system's importance lies in the fact that it has high efficiency to extinguish fire by reducing the oxygen content of the protected area below the point where it can support combustion. Designed to withstand every climatic conditions, these devices are widely used in following area of applications: Transformers Power Generators Machinery Spaces Ships Holds Electrical Equipments Chemical Equipments Chemical Work & Stores Switch Rooms Electric Movers Solvent Stores Dip Tanks Oil Cellars etc.
23 Hydrant, Wet Riser & Sprinkler System It is a well designed & well laid hydrant system which extinguish fires of serious proportions in all classes of risks. It has the ability to continues to be in full operation even if part (s) of affected buildings &/ or structures have collapsed & also keeps cool all adjoining properties. It is also a part of hydrant system to provide a pipe permanently charged with water under pressure rising through the full height of the building. Sprinkler system is most popular system because of its vide applications in fire industries. It has two function to perform firstly, it detect a fire and them provide an adequate of water spray only over the vicinity of fire. Application: Industrial/ Non Industrial Buildings Institutional Buildings Residential Apartments Hotel & Hospitals Mall & Multi Storied Complexes Chemical & Flammable Storage Yards Medium Velocity Water Spray System Designed in accordance to international standards, this system is installed to control the burning and to provide cooling and/ or exposure protection to such risks where extinguishment is always not possible or even desirable. Some of the areas where this system is widely used are: Working plants like LPG bottling plants, chemical plants where flammable solvents are stored and/ or used etc. Horizontal storage vessels (like LPG Bullets, NH3 storage tanks etc.) Vertical storage vessels (like benzene, xylene, toluene tankage etc.) Spherical storage vessels (like LPG bullets, spheres etc.) Spot protection (Protection of selective areas/ equipments) High Velocity Water Spray Systems It is a well designed water based fire protection system. Being considered to be the backbone of the entire fire fighting system, high velocity water spray system is one of main water based fire protection system which is installed to extinguish fires involving liquids with flash point 65 C (150 F) or higher. Three principles of extinguishing are employed in the system-emulsification, cooling and smothering. The result of applying these principle is to extinguish the fire within a few seconds. Some of the areas where this system is extensively used are : Transformers, Oil Filled Equipments of Power Stations, Turbo-alternators and other
24 Oil Fired Boiler Rooms, Oil Quenching Tanks Sprinklers Our fire sprinklers are extensively used for active fire protection measures. The fire sprinklers consist of a water distributing piping system which can be connected to a water supply system when used. Our fire sprinklers find application in factories and large commercial buildings, residential complexes etc. These fire sprinklers are available at cost effective prices. Water Mist System It is a system where water in the mist form expands almost three dimensionally. It takes heat from the fire source. In this process water mist evaporates and volume of the water mist increases by 1640 times leads to reduction of oxygen at the source of fire. Water mist is spreading not only in to the direction of fire source but also away from if effectively sealing the Oxygen in flow. This System extinguish the fire effectively & within a very short period. Some of the area s where it is extensively used are: Transformers Wet Benches Flammable Liquid Storages Crude Oil Pumps Gas Compressors Gas Turbines Electrostatic Coatings Chemical Processes Paint Spray Rooms Engine Test Cells Generators Rooms Machine Spaces BOC FS 125 (NAF S125) For certain important places ( like Computer Rooms, Control Rooms, Switch gear Rooms, Data Storage Rooms, Server Room, Museum, Data storage Archive, Libraries, Laboratories etc.) Fire suppression with conventional water-based systems such as sprinklers can damage to your assets. In fact, for these costly & critical areas, you need only a Gas based Fire Suppression System. To meet your requirement & providing the best solution of Gas based Fire Suppression System for occupied areas & also the best alternate for Halon Gas Fire Suppression System (which has been phased out due to its ozone depletion potential), we have made an association with M/s BOC India Ltd. a well known, billion dollars company of Linde Group UK, for their latest launched product of BOC FS125 Fire Suppression System using NAF S125 Extinguishing agent manufactured by Safety Hi- Tech Italy. ALUMINIUM LADDERS
25
26
27
28 SIZE TYPE L M H SH FINISH HIGHEST STANDING LEVEL M H L BOTTOM WIDTH MASTER CARTON 1+1 1' 14.6" 4 PCS 2+1 2' 16.6" 4 PCS 3+1 3' 18.6" 2 PCS 4+1 4' 20.6" 2 PCS TYPE FINISH Note# Blank Box - Means Not Available
29 SIZE TYPE L M H SH FINISH HIGHEST STANDING LEVEL M H L BOTTOM WIDTH MASTER CARTON 4' 3' 17.2" 6 PCS 5' 4' 18.6" 6 PCS 6' 5' 20.2" 6 PCS 7' 6' 21.6" 4 PCS 8' 7' 23.2" 4 PCS TYPE FINISH Note# Blank Box - Means Not Available
30 SIZE TYPE FINIS H HIGHEST STANDING LEVEL BOTTOM WIDTH MASTER CARTON 4' 3' 17.2" 6 PCS 5' 4' 18.6" 6 PCS 6' 5' 20.2" 6 PCS 7' 6' 21.6" 4 PCS 8' 7' 23.2" 4 PCS 10' 9' 26.2" 4 PCS 12' 11' 29.2" 4 PCS 14' 13' 32.2" 4 PCS 16' 15' 35.2" 4 PCS 18' 17' 38.2" 4 PCS 20' 19' 41.2" 4 PCS 22' 21' 44.2" 2 PCS L M H SH L M H
31 24' 23' TYPE 47.2" 2 PCS FINISH Note# Blank Box - Means Not Available L M H 4+5 8' 4' 4PCS ' 5' 4PCS ' 6' 4PCS ' 7' 4 PCS ' 8' 4 PCS ' 10' 4 PCS ' 12' 4 PCS ' 14' 4 PCS ' 16' 4PCS
32 ' 18' 4PCS ' 19' 4PCS TYPE FINISH Note# Blank Box - Means Not Available Emergency Rescue Tenders
33 Water Foam Tender
34 Hydraulic machines
35 WATER TANKER
36 Foam tender
37 Specialized units
38 Aerial hydraulic platform
39 Hydraulic rescue tools CFT (Crash Fire Tender) Crash Fire Tenders are used for extinguishing fire in the event of air crash. In order to avoid wasting precious seconds the run to the crash situation across the airport must not only be as fast, but also as short as possible whereby small obstacles, fences and hedges are driven over. The vehicles should also be able to cross-difficult grounds at a very high speed. Our CFT Vehicles are well equipped to handle such situations. These CFTs are fitted with long range Monitors and fire fighting equipments besides rescue equipment like breathing apparatus sets, fire proximity suits, hydraulic rescue tools and power saw. These vehicles also support an R/T communication system and public address facility to handle all kind of emergencies.
FIRE SUPPRESSION SYSTEM
FIRE SUPPRESSION SYSTEM An effective fire suppression systems work fundamentally in three ways; The corner stone has to be an efficient means of early warning/detection. Followed by either an Oxygen reduction
More informationBOC FS125 The Fire Extinguishing Solution
BOC FS125 The Fire Extinguishing Solution Background - Montreal Protocol With the introduction of the Montreal Protocol in 1987, Halon is no longer available in most countries and alternatives must be
More informationOur Mission. About Us. To create awareness of the essentiality attached to a firefighting system, as an important requisite in everyday life and loss
About Us Among the several Fire Fighting Engineering and Consultation Companies, We proudly acclaim ourselves as one of the leading company, since the recent years. Our potential to the overall efficiency
More informationHI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen
HI-FOG for buildings Technical introduction Jussi Tiainen Protecting people, property and business continuity Contents Introduction to HI-FOG...3 How HI-FOG fights fire...4 Principles of HI-FOG system
More informationHKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009
(II) 23, 25 June and 7, 9 July 2009 Organization by Co-organized by the Association of Registered Fire Service Installation contractors of Hong Kong Ltd (FSICA) Gas and Foam Suppression Systems Peter Bressington
More informationPRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems
PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems DETECT-SUPPRESS-PROTECT THE INERGEN CLEAN AGENT SYSTEM FROM ANSUL INERGEN IS BETTER FOR YOUR PROPERTY Upon discharge, INERGEN instantly
More informationCO2 COCO GAS FLOODING SYSTEM
PRE INTRODUCTION: CO2 COCO GAS FLOODING SYSTEM The importance of erection, testing and commissioning are overlooked, in many projects while installing fixed Co2 extinguishing system. It is very common
More informationInstitute for Plasma Research Welcomes you all on
Institute for Plasma Research Welcomes you all on Presented By: D.V.MODI, Safety Officer, IPR Compiled by: SAFETY COMMITTEE, IPR WHAT IS FIRE? The self-sustaining process of rapid oxidation of a fuel,
More information+91-8048763768 Cease Fire & Electrical Services http://www.ceasefireengineers.com/ We are the supplier, trader and service provider of fire alarm equipment, fire suppression system, fire detection system,
More informationHow can you minimize consequential damages in case of a fire?
How can you minimize consequential damages in case of a fire? With intelligent extinguishing solutions from Siemens. Sinorix 227 fast, effective, and reliable. Answers for infrastructure. Reliability the
More informationFire Suppression Systems
Fire Suppression Systems www.watermist.com Public Buildings Custodial Food Industry Transportation Power Generation The Hydramist product range was created to address fast, safe and efficient water based
More informationDesign and Supply of Fire Equipments. External Fire Fighting Systems.
Design and Supply of Fire Equipments External Fire Fighting Systems INTRODUCTION Sheyas fire Services is one of the progressive firms in the field of Fire Fighting Equipment s and Consulting Services,
More informationVaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS
Protect your Media Vault Protect your Assets Fire Protection Services Vaults Presented by Peter Glodic Introduction Vault Types VAULTS Vault Types Vault Construction Media Types Fire Types Extinguishing
More informationWhat is HI-FOG? The natural enemy of fire
What is HI-FOG? The natural enemy of fire Using water wisely in the fight against fire COOLS HI-FOG attacks the fire, cooling the fire itself and the space it is in. Water absorbs more heat (>2 MJ/kg)
More informationBranch Solution Wood based panel plants. Fire protection solutions for wood based panel plants
Branch Solution Wood based panel plants Fire protection solutions for wood based panel plants afety throughout the production process R The versatility of wood as a raw material and the fact that it is
More informationRE: BASIC FIRE SAFETY PROCEDURES AND OPERATION OF FIRE EQUIPMENT
March 15, 2016 Security Staff Training Memo RE: BASIC FIRE SAFETY PROCEDURES AND OPERATION OF FIRE EQUIPMENT Dear Staff Officers: As part of your daily rounds, security officers must look out for any unsafe
More informationAn Overview of Extinguishing Systems for Computer Equipment
Risk Solutions An Overview of Extinguishing Systems for Computer Equipment Various types of automatic suppression systems are available for protecting computer equipment. This report discusses the uses
More informationMistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.
MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. 2 MistMax Low pressure WaterMist fire suppression skid Our modular fire skid is customised to suit your specific
More informationFIRE PROTECTION TECHNOLOGY Solutions never thought of before
FIRE PROTECTION TECHNOLOGY Solutions never thought of before More than 25 years in engineering, manufacturing and maintenance of certified fire fighting systems and products. TEMA SISTEMI There was a time
More informationPLUS SIZE EXTINGUISHERS CEASEFIRE PLUS
PLUS SIZE EXTINGUISHERS CEASEFIRE PLUS Ceasefire Plus 01 THE BIGGEST CONTRIBUTOR TOWARDS FIRE ACCIDENTS IS SHORT CIRCUIT. It s a well-known fact that the major contributor towards fire accidents today
More informationPortable Fire Extinguishers
Portable Fire Extinguishers Workbook Activities The following activities have been designed to help you. Your instructor may require you to complete some or all of these activities as a regular part of
More information- CONSTRUCTION FIRE SAFETY STANDARDS
SGG15 - CONSTRUCTION FIRE SAFETY STANDARDS 1) Hot Work Permits All construction sites shall implement a system of Hot Work Permits for all work activities that generate heat, sparks or flames. All of the
More information- CONSTRUCTION FIRE SAFETY STANDARDS
SGG15 - CONSTRUCTION FIRE SAFETY STANDARDS 1) Construction Planning All construction sites shall plan and sequence their construction activities to ensure the early installation and operation of permanent
More informationBALAJI FIRE PROTECTION SYSTEMS:
BALAJI FIRE PROTECTION SYSTEMS: Automatic Water Sprinkler System: One of the oldest & traditional ways of fire protection, which is water based protection system, is in the form of automatic sprinklers.
More informationSuperior by Design The Kidde ADS TM FM-200 System
A UTC Fire & Security Company Superior by Design The Kidde ADS TM FM-200 System Engineered to Provide Exceptional Performance The Kidde ADS FM-200 System is an innovative system developed by Kidde engineers
More informationActive & Passive Fire Protection System. Page 1 Kalidasan S BT IN SSP-OP
Active & Passive Fire Protection System Page 1 Kalidasan S BT IN SSP-OP Fire Protection - Introduction Introduction: The definition of fire protection of a building refers to the building ability to detect,
More informationGAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems
GAS EXTINGUISHING SYSTEMS Argon Extinguishing Systems Fire Protection Systems EFFECTIVE NATURAL no damage to the atmosphere technology for complex applications EXAMPLE GAS EXTINGUISHING SYSTEMS solution
More informationFire protection for buildings
Fire protection for buildings HI-FOG high-pressure water mist Ghelamco Group Protecting people, property and business continuity A fire in a building can lead to serious consequences. Even a harmless fire
More informationCO 2 EXTINGUISHING SYSTEMS
CO 2 EXTINGUISHING SYSTEMS CO 2 THE FIRE EXTINGUISHING CLASSIC: CLEAN, FAST AND RELIABLE TOTAL WALTHER, the acknowledged specialist in fire protection systems, has been manufacturing CO 2 extinguishing
More informationElement C3.4 Fire Fighting Equipment
.4 Fire Fighting Equipment Classification of Fires Class A Solids. Wood, paper, plastics Class B Liquids Petrol oil, paint Class C Gases LPG, natural gas Classification of Fires Class D Metals Zinc, sodium,
More information"USING FIRE EXTINGUISHERS"
PRESENTER'S GUIDE "USING FIRE EXTINGUISHERS" Part of the "SAFETY MEETING KIT" Series Quality Safety and Health Products, for Today...and Tomorrow OUTLINE OF MAJOR PROGRAM POINTS The following outline summarizes
More informationInternational Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING
Chapter 30 FIRE-FIGHTING This Chapter discusses events which may follow cargo spillage and the procedures which can be adopted to protect life and property in such circumstances. It also describes the
More informationMAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems
MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems ANSUL PIONEERED DRY CHEMICAL FIRE PROTECTION IN 1939, WHICH HELPED CREATE LARGE DRY CHEMICAL SYSTEMS WITH SUPERIOR FIREFIGHTING CAPABILITIES
More informationPerformance Based Fire Protection With Water Mist
Performance Based Fire Protection With Water Mist the applications to industrial hazards, high rise buildings and other areas of interest PART 1 PART 2 PART 3 PART 4 PART 5 Marioff Corporation Why use
More informationUCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES
Mandatory Fire Safety Instruction UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES Principal Contractor fire safety considerations in shared occupancy project or refurbishments
More informationUsing Fire Extinguishers. Leaders Guide and Quiz
! Using Fire Extinguishers Leaders Guide and Quiz 3578 INTRODUCTION TO THE PROGRAM Structure and Organization Information in this program is presented in a definite order so that employees will see the
More informationPRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems
PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems D E T E C T - S U P P R E S S - P R O T E C T T H E I N E R G E N C L E A N A G E N T S Y S T E M F R O M A N S U L INERGEN IS BETTER FOR
More informationFANERGY Far more than just a fan.
FANERGY Far more than just a fan. Protects emergency crews. Saves lives. 2 Rosenbauer FANERGY FANERGY Rosenbauer The crucial difference New All In One Airflow Technology Powerful Pull-out fan unit Largest
More informationWATER MIST CONVENTION AND EXHIBITION
INTERNATIONAL WATER MIST ASSOCIATION IWMA SEMINARS S ON WATER MIST TECHNOLOGY DUBAI INTERNATIONAL CONVENTION AND EXHIBITION CENTRE Water mist fire protection: The most innovative fire fighting technology
More informationCarbon Dioxide Fire Suppression Systems
Carbon Dioxide Fire Suppression Systems The original "clean agent," carbon dioxide suppresses fire without leaving behind water, foam or dry chemical to damage sensitive equipment. And because there is
More informationWE RE PUTTING FIREFIGHTING ON AUTO-PILOT CEASEFIRE LAUNCHER:
WE RE PUTTING FIREFIGHTING ON AUTO-PILOT CEASEFIRE LAUNCHER: Extinguisher + Suppression System Ceasefire Launcher 01 IN A FIRE SITUATION, YOUR FIRST REACTION IS TO RUN. No matter how state-of-the-art the
More informationTechnologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea
Technologies Gas extinguishing systems MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea ire protection Efficient and compact MX 200 fire extinguishing systems fight fires using HFC-227ea.
More informationCertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML
CertifiedSafetyPassion SAFETY HI - TECH. Founded in 1990, Safety Hi-Tech is a customer-focused provider of innovative fire suppression solutions, focusing on Clean Agent Extinguishing Systems. Safety Hi-Tech
More informationSafer.Smarter.Tyco. Watermist fire protection Technology you can trust
Safer.Smarter.Tyco. Watermist fire protection Technology you can trust / 2 / / 3 / Trust in Tyco Tyco s AquaMist Systems Tyco Fire Protection Products helps to keep people, property and the environment
More informationEnclosure 4- RISK ASSESSMENT
Enclosure 4- RISK ASSESSMENT RISK ASSESSMENT Risk is a potential that a chosen action or activity will lead to a loss of human or property. Risk assessment is a step for Risk Management. Risk assessment
More informationFire suppression systems for server rooms and data centres
Fire suppression systems for server rooms and data centres Fire suppression systems for server rooms and data centres Fire suppression systems for server rooms and data centres are essential to the server
More informationSchool of Fire & Safety, GSFC University
School of Fire & Safety, GSFC University Course Structure & Syllabus for Certificate Course in Fireman/ Firewoman First Month:- Fire Science: General Introduction to Science of Fire (Basics of Physics
More informationPERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers
PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers MODEL 5 The Model 5 has a slim design for use on vehicles and machinery where space is limited. Typical applications include small trucks,
More information2007 CBC & CFC Residential Care Facility Requirements (24 hour care only)
2007 & CFC Residential Care Facility Requirements (24 hour care only) Occupancy Construction Smoke Barrier I-1 Bedridden 7+non- Ambs Or bed- Ridden R-4 7+ambs (May have 6 nonambs or 6 bedridden) R-3.1
More informationSafety Manual Section 7 Fire/Life Safety
7. FIRE/LIFE SAFETY The following sections provide fire/life safety guidelines and procedures. This section covers the following topics: Topic Page 7.1 General... 7-2 A. The Effects of a Fire... 7-2 B.
More informationFollowing are the systems proposed as per NBC & Local Fire Authority:
1. OBJECTIVES AND STRATEGIES OF THE FIRE PROTECTION DESIGN This report describes the design parameters, system requirements of fire protection system for mixed occupancy (Assembly + Business) building
More informationDRY POWDER FIRE EXTINGUISHER (Stored Pressure) ABC TYPE - PORTABLE
DRY POWDER FIRE EXTINGUISHER (Stored Pressure) ABC TYPE - PORTABLE Capacity: 1,, 5, 10 Kgs UFS dry powder type extinguishers are designed for protection of light and ordinary hazards. Suitable for A, B,
More informationOsceola County Department of Fire Rescue and Emergency Medical Services
St. Number Dir Street Name Street Type Inspected Time of Day to be Re-inspected Zip Code Occupancy Type Emergency Contact Phone (Inc. Area Code) Building Owner Building Owner Mailing Address Bldg. Owner
More informationDCN: ENGINE COMPANY OPERATIONS CHAPTER 4 March 15, 1997 FIRE SCENE OPERATIONS
DCN: 4.05.01 ENGINE COMPANY OPERATIONS CHAPTER 4 March 15, 1997 FIRE SCENE OPERATIONS 4. FIRE SCENE OPERATIONS 4.1 FIREFIGHTING OBJECTIVES 4.1.1 The objectives of firefighting are to protect life and property
More informationSTANDARDS FOR ACTIVE FIRE PROTECTION. Stewart Kidd Loss Prevention Consultancy Ltd
STANDARDS FOR ACTIVE FIRE PROTECTION Stewart Kidd Loss Prevention Consultancy Ltd This presentation will consider: The risks to both new and existing buildings which can be countered by active fire protection
More informationFOREFRONT AT THE OF PROTECTION
AT THE FOREFRONT OF PROTECTION SIEX WF B combines the benefits of water as an extinguishing agent with the most innovative advances to achieve fire protection causing the least possible damage and exceeding
More informationWelcome to Argonite fire protection from Ginge-Kerr
Welcome to Argonite fire protection from Ginge-Kerr Looking for fire protection of high value areas? Then you've come to the right place. As Halon systems go out, the Argonite system is coming in. All
More informationSTORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop
STORED PRESSURE 50, 125/150 lb. Stored Pressure These commercial stored pressure extinguishers are available in a choice of two sizes and three chemical options. The carriage design on both sizes provides
More informationFANERGY Far more than just a fan.
FANERGY Far more than just a fan. Protects emergency crews. Saves lives. 2 Rosenbauer FANERGY FANERGY Rosenbauer The crucial difference New All In One Airflow Technology Powerful Pull-out fan unit Largest
More informationDelhi Metro System. Emergency and Fire Safety Measures in. - by Sanjeev Kumar & Kailash Chandra Joshi. Fire Protection & Safety
Emergency and Fire Safety Measures in Delhi Metro System - by Sanjeev Kumar & Kailash Chandra Joshi 40 MARCH-APRIL 2017 FSAI Journal Delhi Metro An Introduction Delhi Metro has been incorporated in 1995
More informationFirst Aspen Federal Regulation Set: K LSC 2000 Health Existing
First Aspen Federal Regulation Set: K 01.01 LSC 2000 Health Existing K 0000 Title CFR Type INITIAL COMMENTS Memo K 0011 If the building has a common wall with a nonconforming building, the common wall
More informationUCL FIRE EXTINGUISHER SCALING & LOCATION POLICY
Fire Safety Technical Note UCL FIRE EXTINGUISHER SCALING & LOCATION POLICY Reference: BS 5306-8: code of practice for fire extinguishing installations and equipment on premises. Selection and installation
More informationTechnologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230
Technologies Gas extinguishing systems MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230 ire protection Efficient and compact MX 1230 fire extinguishing systems fight fires using Novec
More informationFULLY INSULATED COMPOSITE STEEL FIRE DOORS
INTRODUCTION FULLY INSULATED COMPOSITE STEEL FIRE DOORS Product Data Sheet No 1 Navfair International Introduces fully insulated composite Steel Fire Doors A most economical, effective and well recognized
More informationSome Important Aspects of Fire Safety Regulations about High Rise Buildings
Some Important Aspects of Fire Safety Regulations about High Rise Buildings Tokyo University of Science Prof. Kyoichi Kobayashi (Dr. of Engineering) Many high rise buildings are being built with awful
More informationSafe, Effective, Environment-friendly
IG-55 (Argon/Nitrogen) Safe, Effective, Environment-friendly Introduction With the phase out of the most commonly used but environmentally damaging Halon 1301 and CO 2 fire suppressant, inert gases are
More informationFIRE AND FIRE FITTING By Mr. Prashant Sansare
FIRE AND FIRE FITTING By Mr. Prashant Sansare What is mean by fire? CASE STUDY What Happened? Late one evening, a large storage tank containing a flammable liquid began to overflow. It was not detected
More informationRISK ASSESSMENT & EMERGENCY PREPAREDNESS PLAN
RISK ASSESSMENT & EMERGENCY PREPAREDNESS PLAN RISK ASSESSMENT The phases of an emergency includes: 1. Risk assessment 2. Mitigation 3. Preparedness 4. Response 5. Recovery Areas of Risk includes: Naturally
More informationHART XL High Sensitivity Smoke Detection
High Sensitivity Smoke Detection Hart XL High Sensitivity Smoke Detection (HSSD) TM is a smoke detection system that is simple to install, commission, service and use yet remains brilliantly capable in
More informationWatermist Systems. Versatile, Affordable Water Mist Fire Suppression. your TRUSTED partner in fire safety
Watermist Systems Versatile, Affordable Water Mist Fire Suppression your TRUSTED partner in fire safety A New Era in Water-Based Fire Protection Water is the safe, natural way to extinguish a fire. But,
More informationGX-20/FM-200 Fire Extinguishing System
GX-20/FM-200 Fire Extinguishing System Halon fire extinguishants were regarded for many years as the most effective fire suppressants for a wide range of applications. Amendments to the Montreal Protocol
More informationautomatic FiReFighTing SYSTeMS in PainT booths
SPECIAL HAZARDS PROTECTION automatic FiReFighTing SYSTeMS in PainT booths hazard type The risks considered, according to existing regulations, are Class A risk: solids fire. Class B risk: fire of flammable
More informationCONTENTS. bawa-speci, Ver Maintenance. 1. INTRODUCTION: 1.1 bawa-speci Version 01
1. INTRODUCTION: 1.1 bawa-speci Version 01 CONTENTS 2. PART I ALL ABOUT MIST SYSTEM: 2.1 Halon alternative system 2.2 Water Mist Technology 2.3 - High Pressure / Intermediate Pressure Water Mist 2.4 Extinguishing
More informationFIRE EXTINGUISHERS. Chapter 2. - Co2 Fire Extinguisher - Dry Foam Fire Extinguisher - Foam Fire Extinguisher - Portable Foam Applicator
FIRE EXTINGUISHERS Chapter 2 - Co2 Fire Extinguisher - Dry Foam Fire Extinguisher - Foam Fire Extinguisher - Portable Foam Applicator CO2 FIRE EXTINGUISHER - Dielectric test at 35000 V at 1mtr distance.
More informationw-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI
W w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI WHY USE WATER MIST? Nowadays and increasingly, water is a scarce commodity. RG W-FOG s innovative design means that the amount of water used for fire protection
More informationChapter 5. Energy Conservation & Fire Safety
Chapter 5 Energy Conservation & Fire Safety For internal circulation of BSNL only Page 1 Introduction: ENERGY CONSERVATION The ever-increasing cost of energy (i.e. Electrical power & diesel) has contributed
More informationAUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS
SPECIAL HAZARDS PROTECTION AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS Hazard type The risks considered, according to existing regulations, are Class A risk: solids fire. Class B risk: fire of flammable
More informationSPECIALITY HOSES EXCELLENCE PRODUCT CATALOGUE
SPECIALITY HOSES EXPERIENCE EXCELLENCE PRODUCT CATALOGUE a MAKE IN INDIA initiative ABOUT US... Mitras Technocrafts Pvt. Ltd., New Delhi is an ISO 9001:2008 Certified Co. manufacturing world class brand
More informationWhite Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications
White Paper The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications Matthew Puzio, Senior Project Engineer, Fluid Control Technology, Victaulic updated
More informationFire. IMO fire control signs - according to IMO Resolution A.654 (16) (mm) 150x x200
IMO fire control signs - according to IMO Resolution A.654 (16) Safety and operating instructions for trained personnel (SIS) - As per ISO 24409, SIS signs are safety-related signs that replicate the symbols
More information+91-8048763428 Alprintz http://www.alprintz.com/ We are engaged in manufacturing, wholesaling and supplying a wide assortment of Name Plates & Signages in South India. These are very popular for excellent
More informationWater Mist Fire Suppression
Water Mist Fire Suppression How less water has a big impact. HELPING PROTECT YOUR BUSINESS AND VALUED ASSETS WITH WATER MIST FIRE PROTECTION SYSTEM INTRODUCTION Many buildings have specific areas that
More informationGAS EXTINGUISHING SYSTEM INERT GAS. Argotec with carbon dioxide. Safe for certain.
GAS EXTINGUISHING SYSTEM INERT GAS Argotec with carbon dioxide Safe for certain. PPLICATIO VERSATILE Reliable extinguishing Fighting fires quickly and effectively is the strong point of Argotec extinguishing
More informationObjective 1: Describe fire alarm systems.
Chapter 20 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Describe fire alarm systems. 1. The purpose of a fire alarm system is to: (1178) A. prevent
More informationHow can I protect invaluable assets and the environment from the effects of a fire?
How can I protect invaluable assets and the environment from the effects of a fire? The Sinorix 1230 Intelligent Suppression Solution ensures the sustainability of your business and the environment. Answers
More informationHFC-227ea FIRE SUPPRESSION SYSTEM
C C L L E E AA NN AA GG E E NN T T F F I I R R E E S S UU P P P P R R E E S S S S I I OO NN HFC-227ea THE MOST TRUSTED FIRE SUPPRESSION SYSTEM ON THE MARKET HFC-227ea The superior design features and exceptional
More informationCreating a safer world!
03 A leader in next generation of the fire extinguishing system The Fire Prevention industry is expected to have great growth potential and a huge impact on the national economy since nowadays the need
More information(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations;
(1979) (Rev.1 1990) (Rev.2 1996) (Rev.3 Jan 2012) Safety features.1 Fire protection and extinction.1.1 General Fire protection arrangements and fire extinguishing systems are to be in accordance with the
More informationDeluge & Preac tion Systems
Deluge & Preaction Systems Deluge Systems are normally used in special hazard installations where water must be applied to an entire area for protection. They use open sprinklers or spray nozzles attached
More informationChapter Nursing Homes
Chapter 16.01 Nursing Homes Section 1. Licensing. No nursing, convalescent or old age home, as defined in Section 2 of this ordinance, shall be operated except under a license from the City Council of
More informationFire Protection of Hotels. With SEM-SAFE High-Pressure Water Mist System
Fire Protection of Hotels With SEM-SAFE High-Pressure Water Mist System Danfoss Semco A/S Total Solution Provider of Certified Fixed Fire Fighting Systems Aesthetic design and reliability with SEM-SAFE
More informationCARTRIDGE EXTINGUISHER
48 CARTRIDGE EXTINGUISHER As mankind continues its march of progress, one threat remains a constant: Fire. Whether it is in state-of-the-art factories, in swank corporate offices or super-speciality hospitals,
More information(h) Pesticide Application.
Fire Code Cannabis Amendment Section 13.20.066 is added to the Marysville Municipal Code to read in its entirety as follows: 13.20.066 Cannabis Growing, Processing, or Extraction Facilities (a) Application.
More informationHiren Industrial Corporation
+91-8048762355 Hiren Industrial Corporation https://www.indiamart.com/hirenindustrial/ We are reputed Manufacturers and Exporters, traders of Fire Fighting & Safety Equipment. We offer Safety Apparel,
More informationAmerican Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J.
American Society of Safety Engineers Professional Development Conference June 9-12, 2008 Session No. 101F Fire Protection Stephen J. Musur CSP, CFPS Chubb Group of Insurance Companies June 12, 2008 1 Fundamentals
More informationTRIMAX ASIA ENGINEERING & CONSTRUCTION (PG U )
TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG0176866-U ) FIRE PROTECTION EQUIPMENTS PARTS CATALOGUE TRIMAX ASIA ENGINEERING & CONSTRUCTION No. 24, Jalan Pantai, 12000 Butterworth, Penang, Malaysia. Fax: +6
More informationPRODUCT MANUAL FIRE EXTINGUISHER. Carbon Dioxide 6.5, 9 & 22.5 Kg Capacity Trolley Mounted (45 kg also as a non standard)
PRODUCT MANUAL FIRE EXTINGUISHER Carbon Dioxide 6.5, 9 & 22.5 Kg Capacity Trolley Mounted (45 kg also as a non standard) Kanadia Fyr Fyter Pvt Ltd Laxminagar, Ghatkopar (E), Mumbai -400 075 Page 1 of 6
More informationRisk Management Department. Fire Extinguishers
Risk Management Department Fire 1 Introduction to Fire Every school facility is equipped with fire extinguishers for staff to use to suppress fires. Used properly, a fire extinguisher can be an effective
More informationHi, welcome to the topic on Fire Detection and Alarm Systems. This topic forms one of the critical knowledge areas for prospective fire safety
Hi, welcome to the topic on Fire Detection and Alarm Systems. This topic forms one of the critical knowledge areas for prospective fire safety manager. As the appointed fire safety manager for a premise,
More informationNEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION EMPLOYER S REQUIREMENTS
Mandatory Fire Safety Instruction NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION EMPLOYER S REQUIREMENTS Reference A: Reference B: Approved Document B
More information