California Society for Healthcare Engineering, Inc. Environment of Care, Life Safety, and Emergency Management Update 2017

Size: px
Start display at page:

Download "California Society for Healthcare Engineering, Inc. Environment of Care, Life Safety, and Emergency Management Update 2017"

Transcription

1 California Society for Healthcare Engineering, Inc. Environment of Care, Life Safety, and Emergency Management Update 2017 Kathy Tolomeo, CHEM, CHSP, Certified Yellow Belt Engineering Department The Joint Commission

2 The Joint Commission Disclaimer This presentation is current as of 3/1/2017. The Joint Commission reserves the right to change the content of the information, as appropriate. This presentation is copyrighted to The Joint Commission and cannot be reproduced or otherwise distributed without express written permission by the speaker. Distribution of the speaker s presentation other than in PDF format is expressly prohibited.

3 Survey Process Survey Analysis For Evaluating Risk SAFER Matrix

4 A New SAFER Matrix

5 A New SAFER Matrix 1.92% 0.96% 4.81% 7.69% 16.35% 16.83% 20.67% 53.85% 13.94% 12.50% 12.02% 32.21% 30.29% 37.50% 38.46%

6 Benefits of SAFER Matrix Focus on patient safety/risk to patients Critical thinking Takes each finding to the next level the so-what? as to why the finding is important Helps surveyors think through each finding to cite at appropriate level of scope and severity Visual representation of survey Indicates severity of findings to organizations for prioritization More clearly identifies the highest risks Aggregate data for standards refinement, improving consistency, etc. January 2017 Perspectives Engineering Department

7 Survey Process Post Survey Follow-up

8 Future Vision Recognize that the potential for an EP to be related to a risk/safety issue depends on the context of the situation during a given survey, and not just on the EP itself. Opportunity to use new SAFER Matrix to direct more customized and prioritized follow-up based on each finding, and better utilize our systems and structures that support improvement. Engineering Department

9 Prioritized Follow-up Action Placement of RFI on SAFER Matrix and Follow-Up Activity LOW / LIMITED MODERATE / LIMITED LOW / PATTERN LOW / WIDESPREAD MODERATE/PATTERN MODERATE/ WIDESPREAD HIGH/LIMITED HIGH/PATTERN HIGH/WIDESPREAD Evidence of Standards Compliance (ESC) 60 Evidence of Standards Compliance (ESC) 60 - Plus - Additional fields for sustainment plan Pull into surveyor technology for potential review during subsequent surveys Engineering Department

10 Customer Impacts: No more Direct and Indirect EP designations No more A or C categories No more OFIs 60 days due date for all ESC Visual grids will be included within the report May 2016 Perspectives Engineering Department

11 Survey Process Reducing Post-Survey Clarifications

12 What is Clarification? After a survey event, organizations have the opportunity to submit clarifying ESC if they believe that their organization was in compliance with a particular standard at the time of Survey. ACC-60 Engineering Department

13 Analyze: Hospital Clarifications 50% of Hospitals (HAP) request Clarifications Dominate clarification themes: Lack of Documentation (65%) Incorrect Findings Survey Process Issues 51% of HAP Clarifications are in the EC & LS Chapters Engineering Department

14 Analyze: Hospital Clarifications Lack of Documentation Hospitals cannot produce all required documents for LSCS review when requested Some documentation is available after the LSCS leaves Remaining survey team unable to review Engineering Department

15 Analyze: Hospital Clarifications Incorrect findings Findings cited at incorrect Standard/EP Survey finding does not document non-compliance at the cited EP Misinterpretation of standards compliance Corridor clutter in a Suite (not required) Limited opportunities to follow-up with Surveyors i.e. observations discussed but implied they will not be cited until the observation appears in the final report leaving no opportunity to discuss with the surveyor Engineering Department

16 Improve: Documentation Issue: Required documentation is not available upon request NFPA requires that documentation related to testing of safety systems must be available at any time, for any inspector, to review By not having the required documentation available at the time of survey, the facility is not in compliance with NFPA requirements Clinical EPs also require documentation i.e. D icons Engineering Department

17 Improve: Documentation NFPA Documentation must be readily available as per NFPA Records. Records of inspections, test and maintenance of the system and its components shall be made available to the authority having jurisdiction upon request. Typical records include, but are not limited to, valve inspections, flow, drain, and pump tests, and trip tests of dry pipe, deluge and preaction valves Records shall indicate the procedure performed (e.g., inspection, test or maintenance), the organization that performed the work, the results and the date Records shall be maintained by the owner. Original records shall be retained for the life of the system. Subsequent records shall be retained for a period of one year after the next inspection, test or maintenance required by the standard. Similar requirements in NFPA , Engineering Department

18 Improve: Documentation Required Documents not available at the time of survey generate RFIs that are not eligible for clarification. The organization must complete the Required Documentation check list prior to the start of survey Sign and date the attestation statement on the checklist In off-survey years, discussion of Required Documentation during ICM events will occur Engineering Department

19 Improve: Survey Process Issues Issue: Findings are cited in error; not at the correct Standard/EP or the finding is a misinterpretation of standards compliance Recommended Solutions: SIG/Surveyor real-time calls during the survey Improved quality of written survey findings As RFIs are identified, surveyors point them out to the customer, explaining why they are RFIs and clearly stating they will be part of the survey report. Engineering Department

20 Improve: Survey Process Issues On-site ESC: Process reviewed during Survey For those observations related to established processes, the RFI remains but if the surveyor affirms the process is effective, they may annotate the finding, reducing the subsequent ECS i.e. the Building Maintenance Program Engineering Department

21 Improve: Survey Process Issues Issue: Organizations are unclear about what to Clarify or how to Clarify Solution: There will continue to be a need for a Clarification Process. Organizations can only clarify observations that they believe have been made in error and are not document related. Engineering Department

22 Survey Resource To prepare for document review, the Survey Activity Guide has been updated to include Life Safety and Environment of Care Document List and Review Tool This new resource is located on The Joint Commission website at code_information resources/ This resource is also at the Joint Commission Connect extranet site Engineering Department

23 Pre-Survey Checklist: EC, EM & LS Engineering Department

24 Pre-Survey Checklist: EC & LS Engineering Department

25 Statement of Conditions Effective August 1, 2016

26 Statement of Conditions - Terms BBI: Basic Building Information Sites are populated by eapp (electronic application) Buildings are created, modified, and deleted by the HCO PFI: Plan For Improvement No longer recognized in the survey process effective August 1, 2016 Organization may continue to utilize as a resource Benefits with new SAFER Matrix Extensions No longer utilized effective August 1, 2016 Organizations may now modify all PFIs in their SOC SPFI: Survey-Related Plan For Improvement TLW: Time Limited Waiver Equivalency: Traditional or FSES (Fire Safety Evaluation System) Engineering Department

27 Statement of Conditions - Background Organizations conduct routine building inspections During inspections deficiencies are discovered Resolution of deficiencies occurs either Immediately NEW FAQ: Immediately Corrected is defined by the Joint Commission as the shift in which the deficiency was identified, plus one additional shift. Scheduled activity (i.e. corrective maintenance) Scheduled activity (i.e. Plan For Improvement ) Engineering Department

28 Statement of Conditions - Background In 1995 the Joint Commission introduced the Statement of Conditions (SOC) [electronic in ] Basic Building Information Plan For Improvement Plan For Improvement (PFI) are the documented observation of a deficiency with a Projected Completion Date Interim Life Safety Measures (ILSM) are an important part of the PFI process ILSM ensures the building remains safe for occupants as interim measures are implemented Engineering Department

29 Statement of Conditions Effective August 1, 2016 the survey process will no longer recognize the PFI process. Surveyors no longer have access to the SOC. CFR Title 42: Public Health (d) Ordinarily a provider or supplier is expected to take the steps needed to achieve compliance within 60-days of being notified of the deficiencies, but the State survey agency may recommend that additional time be granted by the Secretary in individual situations, if in its judgment, it is not reasonable to expect compliance within 60-days, for example, a facility must obtain the approval of its governing body, or engage in competitive bidding. Engineering Department

30 Statement of Conditions All RFIs effective January 1, 2017 will have a 60 day ESC from the last day of survey. If a physical environment deficiency that is scored under EC or LS cannot be resolved within the 60 day ESC, no later than 30 days from the last day of survey the organization must submit for a SPFI and a TLW. If the organization is planning on submitting an Equivalency, the SPFI and TLW may be submitted prior to the submission of the Equivalency. The organization s SPFI and TLW request should consider the time to develop and approve an equivalency. Once the Joint Commission approves an equivalency it will be documented in the organization s History/Audit Trail and then sent to CMS for approval (if applicable). Engineering Department

31 Statement of Conditions The organization does not need to have an approved SPFI or TLW for the ESC submission. They just need to be submitted. Follow-up surveys need to either show: 1. The RFI has been corrected 2. Evidence that the RFI will be completed within the 60 day ESC (work order, invoice, etc.) 3. A submitted SPFI and a Joint Commission approved TLW TLWs and Equivalencies are only sent to CMS for deemed status HCOs Engineering Department

32 Statement of Conditions (SOC) Documenting your mitigation actions Engineering Department

33 Time Limited Waiver (TLW) A Time Limited Waiver is a process to provide additional time to complete Life Safety Chapter corrective actions Organizations that use Joint Commission accreditation for deemed status purposes are to follow this process: Create a Survey-related Plan For Improvement (SPFI) Enter the requested date in the Scheduled Completion Date field When prompted, complete the Time Limited Waiver form Submit to the Joint Commission The Joint Commission will review and forward the request to the Regional Office for final decision Once the final RO decision has been made the Department of Engineering enters the organization SPFI and accepts the new date After the Department of Engineering modifies the SPFI they will annotate the History Audit Trail Engineering Department

34 Time Limited Waiver (TLW) A Time Limited Waiver is a process to provide additional time to complete Life Safety Chapter corrective actions Organizations that DO NOT use Joint Commission accreditation for deemed status purposes : Create a Survey-related Plan For Improvement (SPFI) Enter the requested date in the Scheduled Completion Date field When prompted, complete the Time Limited Waiver form Submit to the Joint Commission The Joint Commission will review the request Once the decision has been made the Department of Engineering enters the organization SPFI and accepts the new date After the Department of Engineering modifies the SPFI they will annotate the History Audit Trail Engineering Department

35 Statement of Conditions Equivalencies

36 CMS & Equivalencies Organizations that use Joint Commission accreditation for deemed status purposes: Survey-related equivalencies will continue to be submitted to our offices The Engineering staff will work with the organizations until the request is acceptable Once the equivalency is considered acceptable the Joint Commission will forward the entire request to the CMS Regional Office (RO) for final decision The CMS RO will send a response to both the organization and Joint Commission If approved the History Audit Trail will be updated If denied, the organization will need to either correct the deficiency or re-submit a corrected equivalency Engineering Department

37 CMS & Equivalencies Organizations that DO NOT use Joint Commission accreditation for deemed status purposes: Survey-related equivalencies will continue to be submitted to our offices The Engineering staff will work with the organizations until the request is acceptable Once the equivalency is considered acceptable the Joint Commission will respond to the organization in the History Audit Trail August 2016 Perspectives Engineering Department

38 Challenging Standards Top 10 Findings

39 Standard Top 10 Findings Comparison 2016 % Noncompliant 2016 Rank Summary EC % 1 Maintain a safe, functional environment IC % 2 Reduces risk of infections associated with equipment, devices and supplies EC % 3 Manage risk associated with Utility Systems LS % 4 Manage the Means of Egress LS % 5 Manage systems for extinguishing fires LS % 6 Building and fire protection general requirements LS % 6 Building and fire protection features PC % 6 Provide care, treatment and services as prescribed EC % 7 Manage risk associated with hazardous materials RC % 7 Maintain complete and accurate medical records Engineering Department

40 #1 EC EP 1 66% EP 1 Interior spaces meet the needs of the patient population and are safe and suitable to the care, treatment and services provided. Cylinder management 2017 Scoring at EC EP 6 Storage Secured, labeled, etc. Segregation Full vs. Empty NFPA o Chapter 11 Gas Equipment o Chapter 5 Gas and Vacuum Systems NEW! Engineering Department

41 #1 EC EP 1 66% EP 1 Interior spaces meet the needs of the patient population and are safe and suitable to the care, treatment and services provided. Outside Cylinder Management 2017 Scoring at EC EP 7 NEW! Previously scored at EC EP 5 Secured Protected for the elements (sun, snow, water, etc.) Protective shipping mesh or wraps NFPA o Chapter 11 Gas Equipment o Chapter 5 Gas and Vacuum Systems Engineering Department

42 #1 EC EP 1 66% EP 1 Interior spaces meet the needs of the patient population and are safe and suitable to the care, treatment and services provided. Relocatable Power Taps (Power Strips) 2017 Scoring at EC EP 14 if in patient care area EC EP 1 if non-patient care NFPA Power strips may be used in a patient care vicinity to power rack-, table-, pedestal-or cart-mounted patient care-related electrical equipment assemblies, provided all of the following conditions are met, as required by section : The receptacles are permanently attached to the equipment assembly. Engineering Department NEW!

43 #1 EC EP 1 66% EP 1 Interior spaces meet the needs of the patient population and are safe and suitable to the care, treatment and services provided. Relocatable Power Taps (Power Strips) The sum of the ampacity of all appliances connected to the receptacles shall not exceed 75 percent of the ampacity of the flexible cord supplying the receptacles. The ampacity of the flexible cord is suitable in accordance with the current edition of NFPA 70, National Electric Code. The electrical and mechanical integrity of the assembly is regularly verified and documented through an ongoing maintenance program. Means are employed to ensure that additional devices or nonmedical equipment cannot be connected to the multiple outlet extension cord after leakage currents have been verified as safe. Engineering Department

44 #1 EC EP 1 66% EP 1 Interior spaces meet the needs of the patient population and are safe and suitable to the care, treatment and services provided. Relocatable Power Taps (Power Strips) Power strips may not be used in a patient care vicinity to power non-patient care-related electrical equipment (e.g., personal electronics). Power strips may be used outside of the patient care vicinity for both patient care-related electrical equipment & nonpatient-care-related electrical equipment. Power strips providing power to patient care-related electrical equipment must be Special-Purpose Relocatable Power Taps (SPRPT) listed as UL 1363A or UL Power strips providing power to non- patient-care-related electrical equipment must be Relocatable Power Taps (RPT) listed as UL Engineering Department

45 #1 EC EP 1 66% EP 1 Interior spaces meet the needs of the patient population and are safe and suitable to the care, treatment and services provided. Relocatable Power Taps (Power Strips) Patient bed locations in new health care facilities, or in existing facilities that undergo renovation or a change in occupancy, shall be provided with the minimum number of receptacles as required by section Power strips providing power to rack-, table-, pedestal-, or cart-mounted patient care-related electrical equipment assemblies are not required to be an integral component of manufacturer tested equipment. Power strips may be permanently attached to mounted equipment assemblies by personnel who are qualified to ensure compliance with section Definitions From NFPA Engineering Department

46 #1 EC EP 1 66% EP 1 Interior spaces meet the needs of the patient population and are safe and suitable to the care, treatment and services provided. Ligature/self harm risks (i.e. BHC) Current Risk Assessment Best Practice Guidelines Design Guide for the Built Environment of Behavioral Health Facilities Stained ceiling tiles Blocked or unlocked (if required by policy) electrical panels 2017 Scoring EC EP 6 NEW! Engineering Department

47 #1 EC EP 1 66% Nurse Call Requirements Inaccessible emergency pull cords Wrapped, Length, or Missing Missing Location and Length EC EP 1 1. State rules and regulations FGI Guidelines or other reputable standards or guidelines. Where optional, TJC requires a risk assessment Length best practice is 4 to 6 inches Engineering Department

48 #1 EC EP 13 66% EP 13 The organization maintains ventilation, temperature and humidity levels suitable for the care, treatment and services provided Scoring EC EP 16 NEW! Ventilation: i.e. doors held open by air pressure; odors Propping doors or lack of self-closing devices can impact air pressure relationship Temperature: Hot / Cold calls Humidity Primary concern is for areas >60%RH Mold growth is possible Signs of moisture build up Understanding when to report Engineering Department

49 #1 EC EP 13 & 20 66% EP 13 The organization maintains ventilation, temperature and humidity levels suitable for the care, treatment and services provided. Can be managed through staff surveillance during the regular course of performing their duties. Includes decentralized locations that include sterile supplies. Knowledgeable staff should examine sterile supplies before use and contact facilities management personnel if space temperature and RH levels are determined to be inadequate. Critical scored at EC EP 15 EP 20 Patient care areas are clean and free of offensive odors Engineering Department

50 Relative Humidity (RH) FGI Guidelines (2010) allows expanding the RH range from 35 60% to 20 60% RH > 35 % RH is based on NFPA , Section % RH is based on ASHRAE See EC EP 1 CMS S&C Hospital, CAH & ASC letter dated 2/20/2015 S&C LSC & ASC permits hospitals and CAH to use a LSC categorical waiver to establish Engineering Department

51 Relative Humidity (RH) CMS S&C Hospital, CAH & ASC letter dated 2/20/2015 stated S&C LSC & ASC permits hospitals and CAH to use a LSC categorical waiver to establish an RH level <35% in anesthetizing (i.e. OR) locations Before electing to use the categorical waiver hospitals and CAHs are expected to ensure the humidity levels in their ORs are compatible with manufactures instructions for use (IFUs) for supplies and equipment used in that setting Engineering Department

52 #3 EC EP 15 56% Ventilation system is unable to provide appropriate pressure relationships, air-exchange rates, filtration efficiencies, relative humidity, and temperature. What is the difference between EC EP 15 and EC EP 13? Criticality EC EP 15 is specific to areas designed to control airborne contaminants. Operating rooms, sterile storage, laboratory, etc. Adjacent area that can impact these areas (i.e. clean and soiled utility, environmental service closets, adjacent non-sterile corridors) Engineering Department

53 #3 EC EP 15 56% Ventilation system is unable to provide appropriate pressure relationships, air-exchange rates, filtration efficiencies, relative humidity, and temperature. Specific areas lack Negative or positive pressures in relationship to adjacent areas Correct number of air changes per hour Filtration Temperature and Humidity Electronic Monitoring VaneOmeter Flutter Strip Testing Engineering Department

54 Screening Tissue test: only to be used as a pre-screening tool to evaluate if further investigation needs to occur To perform the flutter test take a tissue and let it hang just off the floor near the bottom edge of a door If the tissue indicates incorrect air flow, stabilize the area by closing doors and windows, wait a few minutes and re-test If the organization presents a Testing & Balancing report the following questions should be asked when was the balancing done (seasonal issues) are any specific requirements (such as keeping a door closed) needed to achieve satisfactory results Engineering Department

55 Survey Process EC EP 15 will generate a CLD If the organization can repair the process that led to non-compliance the LSCS may review Following LSCS review, the LSCS may contact the Central Office to discuss the possibility of reducing the CLD to SLD, with no change to the finding Resolution should include the area affected by the equipment identified as non-compliant, not just the identified room/area i.e. ensure zone is balanced Is there an ongoing process to assess Engineering Department

56 #4 LS % EP 1 Doors in a means of egress are not equipped with at latch or lock that requires the use of a tool or key from the egress side. Unless permitted by one of the following: (1) Locking arrangements complying with (2) Delayed Egress (3) Access Controlled (4) Elevator lobby exit access door (5) Approved existing door-locking installations Engineering Department

57 #4 LS % Locking arrangements complying with : : Where the clinical needs of patients require specialized security measures or where patients pose a security threat. Must meet : 1. Provisions for rapid removal of occupants by one of the following: a) Remote control of locks b) Keying of all locks to keys carried by staff at all times c) Other such reliable means available to the staff at all times 2. Only one locking device on each door 3. More than one lock, must be approved by AHJ Engineering Department

58 #4 LS EP 1 50% Locking arrangements complying with : Door-locking arrangements shall be permitted where patient special needs require specialized protective measures for their safety, provided that all of the following are met: 1) Staff can readily unlock doors at all times in accordance with ) Smoke detection system throughout the locked space or locked doors can be remotely unlocked at a constantly attended location within the locked space. 3) Building is protected throughout by an supervised automatic sprinkler system. 4) Release upon loss of power 5) Release by activation of smoke detection and/or waterflow Engineering Department

59 #4 LS EP 1 50% Special Locking Arrangements ensure they meet all of the requirements: Delayed-Egress Locking Systems Allowed on door assemblies serving low and ordinary hazards in buildings protected by an approved automatic fire detection system OR and approved automatic sprinkler system. Door leaves shall unlock upon actuation of one of the following: Sprinkler system Not more than one heat detector Not more than two smoke detectors Loss of power controlling the lock or locking mechanism Engineering Department

60 #4 LS EP 1 50% Special Locking Arrangements ensure they meet all of the requirements: NEW! Delayed-Egress Locking Systems Irreversible process shall release the lock with 15 seconds (30 seconds where approved by AHJ) Force shall not exceed 15 lbf. Force shall not be required to be continuously applied for 3 seconds Audible alarm Relocking shall be my manual means only Sign Push Until Alarm Sounds Door Can Be Opened in 15 Seconds Egress side of doors equipped with delayed-egress locks shall be provided with emergency lighting. Engineering Department

61 #4 LS EP 1 50% Special Locking Arrangements ensure they meet all of the requirements: Access-Controlled Egress Door Assemblies Electrical lock hardware that prevents egress, provided that ALL the following criteria are met: Sensor on egress side, arranged to unlock upon detection of approaching occupant. Loss of power to the sensor OR to part of the access control system that locks the door leaves Manual releasing device complying with ALL of the following: o Located on egress side 40 in. to 48 in. vertically above the floor, and within 60 in. of the secured door opening. Engineering Department

62 #4 LS EP 1 50% Special Locking Arrangements ensure they meet all of the requirements: Access-Controlled Egress Door Assemblies o Located on egress side 40 in. to 48 in. vertically above the floor, and within 60 in. of the secured door opening. o Sign Push To Exit o When operated it shall result in direct interruption of power to the lock and shall remain unlocked for not less than 30 seconds. Activation of the building fire-protective signaling system and/or automatic sprinkler system and remain unlocked until the system has been manually reset. Engineering Department

63 #4 LS EP 1 50% Special Locking Arrangements ensure they meet all of the requirements: Access-Controlled Egress Door Assemblies Activation of manual fire alarm boxes shall not be required to unlock. The egress side of access-controlled egress doors, OTHER than existing access-controlled egress doors, shall be provided with emergency lighting. (Different than delayed-egress!) Elevator Lobby Exit Access Door Assemblies Locking Engineering Department

64 #4 LS % EP 13 The hospital maintains the integrity of the means of egress Anything in the egress corridor more than 30 minutes is storage Dead end corridors may be used for storage Less than or equal to 50 sq.ft. space Wheeled equipment allowed as long as all of the following is met: a) The unobstructed corridor width shall not be less than 60 inches in width b) Fire safety plan and training program address the relocation of the wheeled equipment during a fire or similar emergency. Engineering Department

65 #4 LS % Wheeled equipment allowed as long as all of the following is met: c) Wheeled equipment is limited to: i. In-use Equipment (i.e. isolation carts, etc.) ii. Medical emergency equipment not in use (i.e. crash carts, etc.) iii. Patient lift and transport equipment Fixed furniture allowances 8 foot corridor Engineering Department

66 #5 LS % EP 4 Piping for the AASS is not used to support any other item. Engineering Department

67 #5 LS % EP 14 Meets all other Life Safety Code automatic extinguishing requirements related to NFPA Missing escutcheons 2017 Scoring LS EP 5 Gap greater than 1/8 scored here NEW! Ceiling tiles misplaced in rooms Blocked access to fire extinguishers Missing K-type signage or within 30 feet required in NFPA Quick response sprinklers mixed with other types in patient sleeping smoke compartments Compartments defined differently in NFPA 13 and 101 Engineering Department

68 #6 LS % Building and fire protection features are designed and maintained to minimize the effects of fire, smoke, and heat. EP 5 Door issues Now EP 5 and EP 7 No blocking or wedging EP 9 Fire Barrier Penetrations Now EP 10 NEW! Barrier Management NEW! NEW! Engineering Department

69 #6 LS % The hospital provides and maintains building features to protect individuals from the hazards of fire and smoke. EP2 Hazardous Areas Primarily door issues EP 11 Corridor Doors Includes suite doors Engineering Department

70 #7 EC % EP 5 The hospital minimizes risk associated with selecting, handling, storing, transporting, using, and disposing of hazardous chemicals. Personal protective equipment Emergency Showers and Eyewash Stations OSHA Reduce the risk of injury from contact with caustic and corrosive materials Risk Assessment OSHA recommends American National Standards Institute (ANSI) standard Z for installation and maintenance Engineering Department

71 #7 EC % ANSI Z for installation and maintenance: Installation: Placed so that the eyewash is within 10 seconds or 55 feet from where the corrosive chemicals is used Tepid water Mixing valve or documentation to validate tepid water Risk assess potential exposure to determine if cold water only would be acceptable Maintenance: Weekly flush until clear is required Annual inspection to ensure the system is fully functional Engineering Department

72 #7 EC % EP 8 Manage hazardous medication disposal risks Inventory EPA RCRA Segregated into toxic or ignitable P: includes epinephrine, nicotine, and warfarin U: includes cyclophosphamide, lindane, melphalan, and mitomycin C Heavy metals and mercury (i.e. vaccines, eye/ear drops, barium) Ignitable - > 24% alcohol Engineering Department

73 #7 EC % EP 11 Has permits, licenses, manifests, and safety data sheets required by law and regulation. OSHA Hazard Communication Standard 29 CFR Department of Transportation (DOT) Title 49 for the Code of Federal Regulation, subchapter C Part 171 Training requirements for staff signing manifests Environmental Protection Agency (EPA), typically state level Cradle to Grave Responsibility Engineering Department

74 #7 EC % EP 12: The hospital labels hazardous materials and waste. Labels identify the contents and hazard warnings* OSHA Bloodborne Pathogen Standards OSHA Hazard Communications Standards National Fire Protection Association (NFPA) See also IC , EP 6; IC , EP 3 Pathological Transfer Containers Tissue Secondary Containers Chemotherapy Clear & Legible Material with trace Written in English chemo (<3%) No P and U-listed waste Engineering Department

75 EC Fire Drills EP 1: The hospital conducts fire drills once per shift per quarter in each building defined as a health care occupancy by the Life Safety Code. The hospital conducts quarterly fire drills in each building defined as an ambulatory health care occupancy by the Life Safety Code. Note 1: Evacuation of patients during drills is not required. Note 2: When drills are conducted between 9:00 P.M. and 6:00 A.M., the hospital may use alternative methods to notify staff instead of activating audible alarms. Note 3: In leased or rented facilities, drills need be conducted only in areas of the building that the hospital occupies. Engineering Department

76 EC Fire Drills EP 3: When quarterly fire drills are required, at least 50% are unannounced. Fire drills are held at unexpected times and under varying conditions. Fire drills include transmission of fire alarm signal and simulation of emergency fire conditions. Note 1: When drills are conducted between 9:00 P.M. and 6:00 A.M., the hospital may use alternative methods to notify staff instead of activating audible alarms. Note 2: For additional guidance, see NFPA : 18/19: 7.1.7; 7.1; 7.2; 7.3. Engineering Department

77 EC Sterilizers EP 4: The hospital conducts performance testing of and maintains all sterilizers. These activities are documented. (See also IC , EP 2). Manufacturer s Recommendations Cleaning Procedures End User managing Daily, weekly, monthly, quarterly, etc. Engineering Department

78 Environment of Care, Emergency Management, & Life Safety Changes to Standards

79 EC EP 8 Deleted Effective 1/1/2017 EP 8 The hospital monitors and reports all incidents in which medical equipment is suspected in or attributed to the death, serious injury, or serious illness of any individual, as required by the Safe Medical Devices Act of Rationale: Required by law or other external requirements. Engineering Department

80 EC EP 12 Deleted Effective 1/1/2017 EP 12 The hospital's procedures address how 12. to obtain emergency repair services. Rationale: Issue should be left to organization discretion. Engineering Department

81 EC EP 23 Deleted Effective 1/1/2017 EP 23 The hospital provides emergency access to all locked and occupied spaces. Rationale: Should be left to organization discretion. Engineering Department

82 EC EP 1 & 3 Deleted Effective 1/1/2017 EP 1 Staff and licensed independent practitioners can describe or demonstrate methods for eliminating and minimizing physical risks in the environment of care. (See also HR , EP 1) EP 3 Staff and licensed independent practitioners can describe or demonstrate how to report environment of care risks. (See also HR , EP 1). Rationale: Should be left to organization discretion. Engineering Department

83 EC EPs 12, 13, & 14 Deleted Effective 1/1/2017 EP 12 The hospital conducts environmental tours every six months in patient care areas to evaluate the effectiveness of previously implemented activities intended to minimize or eliminate environment of care risks. (See also EC , EP 1) EP 13 The hospital conducts annual environmental tours in nonpatient care areas to evaluate the effectiveness of previously implemented activities intended to minimize or eliminate risks in the environment. (See also EC , EP 1) EP 14 The hospital uses its tours to identify environmental deficiencies, hazards, and unsafe practices. (See also EC , EP 1; EC , EP 1) Rationale: Should be left to organization discretion. Engineering Department

84 EC EP 1 Deleted Effective 1/1/2017 EP 1 Representatives from clinical, administrative, and support services participate in the analysis of environment of care data. (See also EC , EPs 3-6 and 8-15) Rationale: Should be left to organization discretion. Engineering Department

85 EC EP 2 Deleted Effective 1/1/2017 EP 2 The hospital evaluates changes to determine if they resolved environmental safety issues. Rationale: Implicit in EC EP 1 Engineering Department

86 CMS Update Emergency Management September 2016 Rule published November 2016 Compliance November 2017 Implementation May 3, 2016 CMS issued the final rule adopting the 2012 Life Safety Code. The rule is effective July 5, This rule also adopt most of NFPA Chapter 7, 8, 12, and 13 are excluded from adoption Roller Latches continue to be prohibited Corridor doors Doors protecting hazardous areas Engineering Department

87 CMS Update ASCs that renders one or more incapable continue to be AHC Outpatient surgical departments There is a provision to allow CMS to waive specific provisions of the Life Safety Code for unreasonable hardship. Engineering Department

88 EC EP 1 At least quarterly, the hospital tests supervisory signal devices on the inventory (except valve tamper switches). The results and completion dates are documented. Note 1: For additional guidance on performing tests, see NFPA : Table Note 2: Supervisory signals include the following: control valves; pressure supervisory; pressure tank, pressure supervisory for a dry pipe (both high and low conditions), steam pressure; water level supervisory signal initiating device; water temperature supervisory; and room temperature supervisory. Engineering Department

89 EC EP 2 Every 6 months, the hospital tests vane-type and pressure-type water flow devices and valve tamper switches on the inventory. The results and completion dates are documented. Note 1: For additional guidance on performing tests, see NFPA : Table Note 2: Mechanical water-flow devices (including, but not limited to, water motor gongs) should be tested quarterly. The results and completion dates are documented. (For full text, refer to NFPA : Table ) Engineering Department

90 EC EP 5 Every 12 months, the hospital tests fire alarm equipment on the inventory for notifying off-site fire responders. The results and completion dates are documented. Note: For additional guidance on performing tests, see NFPA : Table Engineering Department

91 EC EP 25 The hospital has written documentation of annual inspection and testing of door assemblies by individuals who can demonstrate knowledge and understanding of the operating components of the door being tested. Testing begins with a pre-test visual inspection; testing includes both sides of the opening. Note: For additional guidance on testing of door assemblies, see NFPA : ; ; NFPA : 4.8.4; 5.2.1; 5.2.3; 5.2.4; 5.2.6; 5.2.7; ; NFPA : Engineering Department

92 EC EP 25 Defined by NFPA 101 (2012 edition) Doors included in the scope of inspection are: (1) Door leaves equipped with panic hardware or fire exit hardware in accordance with These are fire-rated doors in any fire-rated barrier. Also included are non-fire-rated doors with panic hardware installed. (2) Door assemblies in exit enclosures. These are fire rated doors. (3) Electrically controlled egress doors. These could be any door in the means of egress that is soequipped. Engineering Department

93 EC EP 25 Defined by NFPA 101 (2012 edition) Doors included in the scope of inspection are: (4) Door assemblies with special locking arrangements subject to Delayed egress locking arrangements Access-controlled egress door assemblies Elevator lobby exit access door assemblies locking. Also include any locking arrangements allowed by 18/ , to include locking arrangements permitted for the clinical needs of patients, patients that pose a security risk, and patients that require specialized protective measures. Engineering Department

94 EC EP 25 Defined by NFPA 101 (2012 edition) Doors included in the scope of inspection are: The minimum scope of inspection is described by Inspectors are to demonstrate competence to perform the scope of inspection. Doors requiring inspection are to be inventoried. Deficiencies are to be documented, and corrective action is to be accomplished without delay and documented. EP 27 Former EP 25 for documentation criteria Engineering Department

95 EC EP 3 The [ORGANIZATION] inspects, tests, and maintains non high-risk equipment identified on the medical equipment inventory. These activities are documented. Note: Scheduled maintenance activities for nonhigh risk medical equipment in an alternative equipment maintenance (AEM) program inventory may be deferred as defined by organization policy, provided the completion rate is not less than 90%. Engineering Department

96 EC EP 3 Centers for Medicare and Medicaid Services (CMS) Note allows for completion rate of 90% for AEM for non-high-risk medical equipment. CMS indicated that 100% of the maintenance has to be completed and that AEM is performed at a frequency defined by the organization s AEM program. Engineering Department

97 EC EP 4 - Corrected Language 2018 The hospital identifies the activities and associated frequencies, in writing, for maintaining, inspecting, and testing all medical equipment on the inventory. These activities and associated frequencies are in accordance with manufacturers recommendations or with strategies of an alternative equipment maintenance (AEM) program. Note 1: The strategies of an AEM program must not reduce the safety of equipment and must be based on accepted standards of practice, such as the American National Standards Institute/Association for the Advancement of Medical Instrumentation handbook ANSI/AAMI EQ56: 2013, Recommended Practice for a Medical Equipment Management Program. Engineering Department

98 EC EP 4 - Corrected Language 2018 Note 2: Medical equipment with activities and associated frequencies in accordance with manufacturers recommendations must have a 100% completion rate. Note 3: Scheduled maintenance activities for high-risk medical equipment in an alternative equipment maintenance (AEM) program inventory must have a 100% completion rate. Scheduled maintenance activities for non-high-risk medical equipment in an alternative equipment maintenance (AEM) program inventory are to be completed at 100%. AEM frequency is determined by the hospital AEM program. Engineering Department

99 EC EP 4 - Corrected Language 2018 The hospital inspects, tests, and maintains nonhigh-risk equipment identified on the medical equipment inventory. These activities are documented. Note: Scheduled maintenance activities for nonhigh-risk medical equipment in an alternative equipment maintenance (AEM) program inventory are to be completed at 100%. AEM frequency is determined by the hospital AEM program. Also applies to the language for EC and EC Engineering Department

100 Summary Surveyors will evaluate the effectiveness of the Medical Equipment Management and Utilities program by reviewing equipment against the organization s program. This will include evaluating the completion of activities related to the inspection, testing and maintaining equipment Engineering Department

101 EC EP 14 The hospital meets all other HealthCare Facilities Code requirements; facilities code for electrical equipment in the patient care vicinity as related to NFPA : Chapter 10. Note: For hospitals that use Joint Commission accreditation for deemed status purposes: the hospital meets the applicable provisions of the Life Safety Code Tentative Interim Amendment (TIA). Library of service manuals, instructions manuals, procedures provided by manufacturer s, maintenance manuals, technical bulletins, specification information and other information for the inspection, testing and maintenance of equipment systems. RPTs, SPRPTs Extension Cords Engineering Department

102 EC EP 8 The hospital labels utility system controls to facilitate partial or complete emergency shutdowns. Note 1: Examples of utility system controls that should be labeled are utility source valves, utility system main switches and valves, and individual circuits in an electrical distribution panel. Note 2: For example, the fire alarm system s circuit is clearly labeled as Fire Alarm Circuit; the disconnect method (that is, the circuit breaker) is marked in red; and access is restricted to authorized personnel. Information regarding the dedicated branch circuit for the fire alarm panel is located in the control unit. For additional guidance, see NFPA : 18/ ; ; NFPA : Engineering Department

103 EC EP 18 Medical gas storage rooms and transfer and manifold rooms comply with NFPA : Ventilation required by NFPA 55 Does not include medical gases and cryogenic fluids that are in use per Chapter 11. Indoor storage or manifold areas and storage or manifold buildings shall be provided with natural ventilation or mechanical exhaust ventilation. EP 19 The emergency power supply system s equipment and environment are maintained per manufacturers recommendations, including ambient temperature of at least 40 F; ventilation supply and exhaust; and water jacket temperature (when required). (For full text, refer to NFPA : ) Engineering Department

104 EC EP 1 For facilities that were constructed, or had a change in occupancy type, or have undergone an electrical system upgrade since 1983, the hospital has a Type 1 or Type 3 essential electrical system in accordance with NFPA 99, 2012 edition. This essential electrical system must be divided into three branches, including the life safety branch, critical branch, and equipment branch. Both the life safety branch and the critical branch are kept independent of all other wiring and equipment, and they transfer within 10 seconds of electrical interruption. Each branch has at least one automatic transfer switch. For additional guidance, see NFPA : ; Engineering Department

105 EC EP 10 Emergency lighting at emergency generator locations. The hospital s emergency power system (EPS) has a remote manual stop station (with identifying label) to prevent inadvertent or unintentional operation. A remote annunciator (powered by storage battery) is located outside the EPS location. Engineering Department

106 EC EP 7 The hospital meets all other HealthCare Facilities Code requirements for electrical distribution, HVAC, as related to NFPA : Chapters 6 and 9. General anesthesia EES critical branch Heating and cooling ASHRAE and Manufacturer s Instructions for medical supply and equipment Smoke control systems in supply and exhaust systems for windowless locations Prevents recirculation Operating rooms are considered wet locations unless risk assessment determines otherwise Wet Location = protected by isolated power or groundfault circuit interrupters. Engineering Department

107 EC EP 7 The hospital meets all other HealthCare Facilities Code requirements for electrical distribution, HVAC, as related to NFPA : Chapters 6 and 9. Testing of hospital-grade receptacles at patient bed locations and where deep sedation or general anesthesia is administered. Initial after installation Replacement Servicing Tamper-resistant Pediatric locations = patient rooms, bathrooms, play rooms, and activity rooms (does not include nurseries). Life safety and critical branch electrical receptacles are a distinctive color or marking. Engineering Department

108 EC EP 1 Now includes EXIT signs in monthly inspections Inventory EP 2 - Proposed EP 3 The hospital performs a functional test of Level 1 stored emergency power supply systems (SEPSS) on a monthly basis and performs a test of Level 2 SEPSS on a quarterly basis. Test duration is for five minutes or as specified for its class (whichever is less). The hospital performs an annual test at full load for 60% of the full duration of its class. The test results and completion dates are documented. Non-SEPSS critical for operations should be tested per manufacturers recommendations. EP 8 At least annually, the hospital tests the fuel quality to ASTM standards. The test results and completion dates are documented. Engineering Department

109 EC EP 2 When the hospital has bulk oxygen systems above ground, they are in a locked enclosure (such as a fence) at least 10 feet from vehicles and sidewalks. There is permanent signage stating OXYGEN NO SMOKING NO OPEN FLAMES. EP 3 The hospital s emergency oxygen supply connection is installed in a manner that allows a temporary auxiliary source to connect to it. EP 4 The hospital tests piped medical gas and vacuum systems for purity, correct gas, and proper pressure when these systems are installed, modified, or repaired. The test results and completion dates are documented. Engineering Department

110 EC EP 6 The hospital implements a policy on all cylinders within the hospital that includes the following: Proper handling and transporting (for example, in carts, attached to equipment, on racks) to ensure safety Physically segregating full and empty cylinders from each other in order to assist staff in selecting the proper cylinder Labeling empty cylinders Prohibiting transfilling in any compartment with patient care rooms Refer to Chapter 11 Formally scored at EC EP 1 Engineering Department

111 EC EP 7 The hospital meets all other HealthCare Facilities Code requirements, gas and vacuum. Category warning systems Transfilling Signage requirements per Chapter 5 and 11 on rooms Additional cylinder storage requirements per Chapter 5 and 11 Engineering Department

112 LS EP 2 In time frames defined by the hospital, the hospital performs a building assessment to determine compliance with the Life Safety chapter. Defined by the organization Depends on the size of the facility May be broken up between survey cycle Engineering Department

113 LS EP 3 The hospital maintains current and accurate drawings denoting features of fire safety and related square footage. Fire safety features include the following: Areas of the building that are fully sprinklered (if the building is partially sprinklered) All hazardous storage areas Locations of all fire-rated barriers Locations of all smoke-rated barriers Sleeping and non-sleeping suite boundaries, including the size of the identified suites Locations of designated smoke compartments Locations of chutes and shafts Any approved equivalencies or waivers Engineering Department

114 LS EP 4 When the hospital plans to resolve a deficiency through a Survey-Related Plan for Improvement (SPFI), the hospital meets the 60-day time frame. Adverse decision = AFS10 Automatic notification sent to Central Office and unannounced survey scheduled The hospital does not remove or minimize an existing life safety feature when such feature is a requirement for new construction. Existing life safety features, if not required by the Life Safety Code, can be either maintained or removed. (For full text, refer to NFPA : ; ) i.e new construction hazardous room required to be 1 hour; 2012 may not diminish Engineering Department

115 LS EP 2 When the hospital identifies Life Safety Code deficiencies that cannot be immediately corrected or during periods of construction, the hospital evacuates the building or notifies the fire department (or other emergency response group) and initiates a fire watch when a fire alarm system is out of service more than 4 out of 24 hours or a sprinkler system is out of service more than 10 hours in a 24-hour period in an occupied building. Notification and fire watch times are documented. (For full text, refer to NFPA : ; 9.7.6; NFPA : ) FAQ: Immediately Corrected is the shift identified, plus one shift. EP 15 Other PROPOSED, but already in SOC. Engineering Department

116 LS EP 2 When building rehabilitation occurs, the hospital incorporates Chapter 43, Building Rehabilitation. (For full text, refer to NFPA : Chapter 43; 18/19.4.3) Includes buildings undergoing a change in use or change in occupancy Additions must comply with Chapter 18 and 43.8 Major rehabilitation (modification of more than 50% or 4500 sq. ft. of the smoke compartment) Sprinkler requirements of non-sprinklered smoke compartments Non-sprinklered buildings sprinkler requirements Engineering Department

117 LS EP 2 When building rehabilitation occurs, the hospital incorporates Chapter 43, Building Rehabilitation. (For full text, refer to NFPA : Chapter 43; 18/19.4.3) EP 8 Requirements for fire-rated doors Now prohibits the blocking or wedging open Engineering Department

118 LS EP 23 Every patient sleeping room has an outside window or outside door except newborn nurseries or rooms intended for less than 24-hour stays (such as obstetrical labor beds, recovery beds, and observation beds in the emergency department). (For full text, refer to NFPA : 18/19.3.8) Note: Windows in atrium walls are considered outside windows. EP 24 In new buildings, the window sill height in patient sleeping rooms does not exceed 36 inches from the floor, except in special nursing care areas (for example, intensive care units, coronary care units, hemodialysis units, and neonatal intensive care units), where window sill height does not exceed 60 inches above the floor. (For full text, refer to NFPA : ) Engineering Department

119 LS EP 7 At least six spare sprinkler heads for each type of system, with associated wrenches, are kept in a cabinet that will not exceed 100 F. (For full text, refer to NFPA : ; ; ; NFPA : ; ; ; ; ; NFPA : 6.2.9; ; ; ) Every type, minimal The stock of spare sprinklers shall include all types and ratings installed and shall be as follows: Under 300 = no fewer than to 1000 = no fewer than 12 Over 1000 = no fewer than 24 Engineering Department

120 LS EP 10 The travel distance from any point to the nearest portable fire extinguisher is 75 feet or less. Portable fire extinguishers have appropriate signage, are installed either in a cabinet or secured on a hanger made for the extinguisher, and are at least four inches off the floor. Those fire extinguishers that are 40 pounds or less are installed so the top is not more than 5 feet above the floor. EP 11 Now specifies the requirement for the placard A placard is conspicuously placed near the extinguisher stating that the fire protection system should be activated prior to using the fire extinguisher. Engineering Department

121 LS EP 1 Smoking is prohibited in any room, ward, or compartment where flammable liquids, combustible gases, or oxygen is used or stored; these areas have signs that read NO SMOKING or display the international symbol for no smoking. In facilities where smoking is prohibited and signs are prominently placed at all major entrances, secondary signs that prohibit smoking in hazardous areas are not required. (For full text, refer to NFPA : 18/19.7.4) Note: The secondary sign exception is not applicable to medical gas storage areas. Engineering Department

122 Catch All EPs At the end of the majority of the Standards are the Catch All Elements of Performance requirements. These are normally less cited items, but may contain future EPs and code requirements under NFPA , NFPA , and other references under Chapter 2. Engineering Department

123 the_physical_environment.aspx Engineering Department

124 Engineering Department

Statement of Conditions

Statement of Conditions Alabama Society for Healthcare Engineering Environment of Care, Life Safety, and Emergency Management Update May 2017 Kathy Tolomeo, CHEM, CHSP, Certified Yellow Belt Engineering Department The Joint Commission

More information

2016 Joint Commission Update

2016 Joint Commission Update 2016 Joint Commission Update Bert M. Gumeringer, MBA, CHFM, FASHE Asst. Vice President-Facilities Operations Texas Children s Hospital August 12, 2016 11:30am-12:30pm Top 10 Findings Comparison-2015 vs.2016

More information

Michigan Society for Healthcare Engineering Environment of Care, Life Safety, and Emergency Management Update

Michigan Society for Healthcare Engineering Environment of Care, Life Safety, and Emergency Management Update Michigan Society for Healthcare Engineering Environment of Care, Life Safety, and Emergency Management Update Kathy Tolomeo, CHEM, CHSP, Certified Yellow Belt Engineering Department The Joint Commission

More information

2017 Accreditation Updates

2017 Accreditation Updates 2017 Accreditation Updates Tennessee Healthcare Engineers Association 2017 Spring Conference Pickwick Landing State Park Counce, Tennessee 38326 Presented May 17, 2017 By Ken Gregory Vice President, Accreditation

More information

The Healthcare Environment Update

The Healthcare Environment Update 2017 The Healthcare Environment Update John Maurer, SASHE, CHFM, CHSP Engineering Department The Joint Commission Engineering Department 2017-1 Most Cited Standards Standard 2015 % Noncompliance 2016 %

More information

Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates

Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates Issued June 28, 207 Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates Environment of Care (EC) Chapter Nursing Care Center (NCC) Accreditation Program Standard

More information

Changes to Environment of Care, Equipment Management, and Life Safety Chapters Related to Life Safety Code Updates

Changes to Environment of Care, Equipment Management, and Life Safety Chapters Related to Life Safety Code Updates Issued September 20, 2017 Changes to Environment of Care, Equipment Management, and Life Safety Chapters Related to Life Safety Code Updates Environment of Care (EC) Chapter Home Care (OME) Accreditation

More information

THE HEALTHCARE ENVIRONMENT UPDATE. Anne M. Guglielmo, Engineer Engineering Department The Joint Commission. Copyright, The Joint Commission

THE HEALTHCARE ENVIRONMENT UPDATE. Anne M. Guglielmo, Engineer Engineering Department The Joint Commission. Copyright, The Joint Commission 2013 THE HEALTHCARE ENVIRONMENT UPDATE Anne M. Guglielmo, Engineer Engineering Department The Joint Commission Standard/NPSG 2012 Non Compliance 2013 Non Compliance (1 st Six Months) RC.01.01.01 61% 55%

More information

Standards Revisions Related to Life Safety Code Update

Standards Revisions Related to Life Safety Code Update Prepublication Issued Requirements The Joint Commission has approved the following revisions for prepublication. While revised requirements are published in the semiannual updates to the print manuals

More information

Other EC and LS documents may be requested by surveyors, as needed, throughout the survey.

Other EC and LS documents may be requested by surveyors, as needed, throughout the survey. Documentation required by the Hospital Accreditation program Life Safety (LS) and selected Environment of Care (EC) standards is presented in the following pages. These documents will be reviewed by the

More information

EC EP 14 All other electrical K-920 equipment in patient care vicinity NFPA , Chapter 10

EC EP 14 All other electrical K-920 equipment in patient care vicinity NFPA , Chapter 10 MSL Healthcare Partners, Inc. Wild Card EPs Paraphrase K-tag # EC.02.04.03 EP 14 All other electrical K-920 equipment in patient care vicinity NFPA 992012, Chapter 10 K-924 K-928 K-931 K-tag Description

More information

Chapter 43, Building Rehabilitation allows for degrees of compliance based on the work category such as the extent of work.

Chapter 43, Building Rehabilitation allows for degrees of compliance based on the work category such as the extent of work. 3610 COMMERCE DR SUITE 817 BALTIMORE MD 21227 P 410.737.8677 F 410.737.8688 www.haifire.com May 5, 2014 Review of Regulations 42 CFR Parts 403, 416, 418, 460, 482, 483 and 485 Medicare and Medicaid Programs;

More information

LIFE SAFETY & FIRE PREVENTION MANAGEMENT PLAN

LIFE SAFETY & FIRE PREVENTION MANAGEMENT PLAN Title/Description: Life Safety & Fire Prevention Management Department: Facilities Management Personnel: All Effective Date: 5/97 Revised: 7/00, 7/01, 7/02, 7/03, 7/04, 7/05, 7/08 LIFE SAFETY & FIRE PREVENTION

More information

2018 Joint Commission Standards What s New in the EC/LS/UM GASHE Annual March Meeting Lake Blackshear Resort

2018 Joint Commission Standards What s New in the EC/LS/UM GASHE Annual March Meeting Lake Blackshear Resort 2018 Joint Commission Standards What s New in the EC/LS/UM GASHE Annual March Meeting Lake Blackshear Resort Presented March 9, 2018 By Ken Gregory, CHSP President Ken Gregory Consulting 1 2018 Joint Commission

More information

Prepublication New Text Jan 2018 Changes to Environment of Care and Life Safety Chapters

Prepublication New Text Jan 2018 Changes to Environment of Care and Life Safety Chapters Prepublication New Text Jan 2018 Changes to Environment of Care and Life Safety Chapters EC.01.01.01 EP3 Related to Life Safety Code Updates Hospital (HAP) Accreditation Program The hospital has a library

More information

New DATE OF BLDG. PERMIT OR PLAN APPROVAL: SURVEYOR (SIGNATURE) TITLE OFFICE DATE REVIEW AUTHORITY OFFICIAL (SIGNATURE) TITLE OFFICE DATE

New DATE OF BLDG. PERMIT OR PLAN APPROVAL: SURVEYOR (SIGNATURE) TITLE OFFICE DATE REVIEW AUTHORITY OFFICIAL (SIGNATURE) TITLE OFFICE DATE DEPARTMENT OF HEALTH & HUMAN SERVICES CENTERS FOR MEDICARE & MEDICAID SERVICES FIRE SAFETY SURVEY REPORT - AMBULATORY SURGICAL CENTERS Medicare 1. (A) PROVIDER NUMBER Identifying information as shown in

More information

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH) Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH) The following represents a review of the Life Safety chapter of the new 2018 Joint Commission CAMH manual for

More information

THE HEALTHCARE ENVIRONMENT UPDATE. George Mills, Director Engineering Department The Joint Commission. Copyright, The Joint Commission

THE HEALTHCARE ENVIRONMENT UPDATE. George Mills, Director Engineering Department The Joint Commission. Copyright, The Joint Commission 2013 THE HEALTHCARE ENVIRONMENT UPDATE George Mills, Director Engineering Department The Joint Commission Standard/NPSG 2012 Non Compliance 2013 Non Compliance (1 st Six Months) RC.01.01.01 61% 55% LS.02.01.20

More information

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

First Aspen Federal Regulation Set: K LSC 2000 Health Existing First Aspen Federal Regulation Set: K 01.01 LSC 2000 Health Existing K 0000 Title CFR Type INITIAL COMMENTS Memo K 0011 If the building has a common wall with a nonconforming building, the common wall

More information

Top 8 Findings & SAFER Matrix for the 2017 ACE Summit & Expo

Top 8 Findings & SAFER Matrix for the 2017 ACE Summit & Expo Top 8 Findings & SAFER Matrix for the 2017 ACE Summit & Expo February 20, 2017 Atlanta, GA Larry F. Rubin CHFM, CHSP, CPE, CEM Life Safety Code Surveyor The Joint Commission Engineering Department 2015-1

More information

TIPS FOR BETTER JOINT COMMISSION SURVEYS

TIPS FOR BETTER JOINT COMMISSION SURVEYS TIPS FOR BETTER JOINT COMMISSION SURVEYS Washington Society for Healthcare Engineering September 21, 2011 Yakima, Washington The BASICS Most Failed Standards. Scoring. Electronic S. O. C. I.L.S.M. Building

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 92 ST - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Type Memo Tag These guidelines are meant solely to provide guidance to surveyors in the survey process. ST - K0100 - General Requirements

More information

Danilo B. Concepcion, CBNT, CCHT-A Operations Manager St. Joseph Hospital Renal Services

Danilo B. Concepcion, CBNT, CCHT-A Operations Manager St. Joseph Hospital Renal Services Life Safety Code Danilo B. Concepcion, CBNT, CCHT-A Operations Manager St. Joseph Hospital Renal Services danilo.concepcion@stjoe.org 714-771-8944 The findings and conclusions in this presentation are

More information

Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates

Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates Issued September 20, 2017 Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates Environment of Care (EC) Chapter Ambulatory Health Care (AHC) Accreditation Program

More information

EXPLORING LIFE SAFETY COMPLIANCE FOR HEALTH CARE

EXPLORING LIFE SAFETY COMPLIANCE FOR HEALTH CARE 2016 EXPLORING LIFE SAFETY COMPLIANCE FOR HEALTH CARE James Woodson, Engineer Engineering Department The Joint Commission HOSPITAL BREAKFAST BRIEFINGS PART 6 Disclosure Statement The following staff and

More information

Center for Clinical Standards and Quality /Survey & Certification Group

Center for Clinical Standards and Quality /Survey & Certification Group DEPARTMENT OF HEALTH & HUMAN SERVICES Centers for Medicare & Medicaid Services 7500 Security Boulevard, Mail Stop C2-21-16 Baltimore, Maryland 21244-1850 Center for Clinical Standards and Quality /Survey

More information

CMS Announcement 3/27/2017. Adoption of 2012 Life Safety Code Health Care Facilities Code. Kenneth Daily, LNHA

CMS Announcement 3/27/2017. Adoption of 2012 Life Safety Code Health Care Facilities Code. Kenneth Daily, LNHA Adoption of 2012 Life Safety Code Health Care Facilities Code Kenneth Daily, LNHA kenn@qissurvey.com CMS Announcement May 2016 Life Safety Code Health Care Code Effective July 5 th Numerous changes many

More information

Presented by: Brad Keyes, CHSP Senior Consultant Keyes Life Safety Compliance, LLC

Presented by: Brad Keyes, CHSP Senior Consultant Keyes Life Safety Compliance, LLC Presented by: Brad Keyes, CHSP Senior Consultant Keyes Life Safety Compliance, LLC Changes to Life Safety Compliance Healthcare leaders will have to deal with many changes in Life Safety compliance when

More information

Agency for Health Care Administration. Eddie Alday Life Safety Code Lead 30 th AHCA Seminar 23 September 2014

Agency for Health Care Administration. Eddie Alday Life Safety Code Lead 30 th AHCA Seminar 23 September 2014 Agency for Health Care Administration Eddie Alday Life Safety Code Lead 30 th AHCA Seminar 23 September 2014 CMS S&C Letter Interpretation CMS- S&C: 13-58-LSC Dated: 08/30/2013 Several Categorical LSC

More information

ASHE Advocacy Team. Q4 ASHE Advocacy Liaison Webinar 12/7/16 12/7/16. Tim Adams, FASHE, CHFM, CHC Director of Leadership Development

ASHE Advocacy Team. Q4 ASHE Advocacy Liaison Webinar 12/7/16 12/7/16. Tim Adams, FASHE, CHFM, CHC Director of Leadership Development Q4 ASHE Advocacy Liaison Webinar 12/7/16 ASHE Advocacy Team Chad E. Beebe, AIA, CHFM, CFPS, CBO, SASHE Deputy Executive Director of Advocacy cbeebe@aha.org Tim Adams, FASHE, CHFM, CHC Director of Leadership

More information

FHCA 2014 Annual Conference & Trade Show

FHCA 2014 Annual Conference & Trade Show FHCA 2014 Annual Conference & Trade Show CE Session #5 Preparing for the Upcoming Code Changes Don t Look Back Tuesday, July 8 8:15 to 9:15 a.m. Canary 3 Operations/Quality Improvement Upon completion

More information

Compliance w/ the 2012 Life Safety Code

Compliance w/ the 2012 Life Safety Code Compliance w/ the 2012 Life Safety Code Implications of the 2012 NFPA Code Set for Existing & New ASCs William E. Lindeman, AIA http://www.weldesigns.com Financial Interest Disclosure The presenter provides

More information

LIFE SAFETY COMPLIANCE: ADAPTING TO THE 2012 LIFE SAFETY CODE

LIFE SAFETY COMPLIANCE: ADAPTING TO THE 2012 LIFE SAFETY CODE California Society for Healthcare Engineering SOUTHERN CALIFORNIA SEMINAR LIFE SAFETY COMPLIANCE: ADAPTING TO THE 2012 LIFE SAFETY CODE 1 PROGRAM AGENDA Adoption of 2012 LSC CMS Final Rule / Amendments

More information

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY Revision No.: 11 Page 1 of 12 I. PURPOSE This procedure establishes a tool to help maintain a safe environment for all patients, visitors and staff by evaluating the loss of a life safety feature during

More information

M E M O R A N D U M. All Licensed Assisted Living Facilities. Felicia Cooper, Deputy State Fire Marshal Administrator Don Zeringue, Chief Architect

M E M O R A N D U M. All Licensed Assisted Living Facilities. Felicia Cooper, Deputy State Fire Marshal Administrator Don Zeringue, Chief Architect M E M O R A N D U M To: From: Approved: All Licensed Assisted Living Facilities Felicia Cooper, Deputy State Fire Marshal Administrator Don Zeringue, Chief Architect Henry Fry, Deputy Assistant Secretary

More information

EC 5.10 FIRE PREVENTION MANAGEMENT

EC 5.10 FIRE PREVENTION MANAGEMENT EC 5.10 FIRE PREVENTION MANAGEMENT The organization manages fire safety risks. 1 The organization develops and maintains a written management plan describing the processes it implements to effectively

More information

ASCs & LSC. Alice Epstein, DFASHRM, FNAHQ

ASCs & LSC. Alice Epstein, DFASHRM, FNAHQ , DFASHRM, FNAHQ Disclaimer The purpose of this presentation is to provide information, rather than advice or opinion. It is accurate to the best of the speaker's knowledge as of the date of the presentation.

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 94 ST - K0000 - Initial Comments Title Initial Comments Statute or Rule Type Memo Tag These guidelines are meant solely to provide guidance to surveyors in the survey process. ST - K0100 - General

More information

Iowa State Fire Marshal

Iowa State Fire Marshal Iowa State Fire Marshal LIFE SAFETY CODE REQUIREMENTS LONG TERM CARE Kyle R. Gorsh, Special Agent in Charge Iowa Department of Public Safety State Fire Marshal Division 2012 LSC & Applicable Standards

More information

2017 CHALLENGING STANDARDS 2018 NEW ELEMENTS OF PERFORMANCE HOSPITAL ENVIRONMENT OF CARE AND

2017 CHALLENGING STANDARDS 2018 NEW ELEMENTS OF PERFORMANCE HOSPITAL ENVIRONMENT OF CARE AND 2017 2017 CHALLENGING STANDARDS AND 2018 NEW ELEMENTS OF PERFORMANCE IN HOSPITAL ENVIRONMENT OF CARE James Woodson, Engineer Engineering Department The Joint Commission DISCLOSURE STATEMENT Disclosure

More information

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #6

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #6 THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #6 WELCOME Moderator: Richard Schieferdecker support.webinato.com Audio 1 QUESTIONS How To Ask a Question: POLLING There will be occasional

More information

Are there any policies regarding outlets that contain USB ports?

Are there any policies regarding outlets that contain USB ports? Answers to the Questions Mark J. Blackburn, P.E., CFPS February, 2016 Question 1 Are there any policies regarding outlets that contain USB ports? There is no direct reference in code about these types

More information

The Impact the Reference Standards in the 2012 Edition of NFPA 101 have on the Operation of Health Care Facilities: NFPA 80 and 99

The Impact the Reference Standards in the 2012 Edition of NFPA 101 have on the Operation of Health Care Facilities: NFPA 80 and 99 The Impact the Reference Standards in the 2012 Edition of NFPA 101 have on the Operation of Health Care Facilities: NFPA 80 and 99 Sharon S. Gilyeat, P.E. Lauren Schrumpf August 8, 2018 Expertly Engineering

More information

Life Safety Code Common Discepancies Course# LSC102. EZpdh.com All Rights Reserved

Life Safety Code Common Discepancies Course# LSC102. EZpdh.com All Rights Reserved Life Safety Code Common Discepancies Course# LSC102 EZpdh.com All Rights Reserved 1. K147 Electrical - Electrical wiring and equipment shall be in accordance with NFPA 70, National Electrical Code. 9.1.2

More information

THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #2

THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #2 THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #2 WELCOME Moderator: Richard Schieferdecker support.webinato.com Audio 1 QUESTIONS How To Ask a Question: POLLING There will be occasional

More information

The Joint Commission: 2018 Update

The Joint Commission: 2018 Update The Joint Commission: 2018 Update Who we are Survey Process and Methods Standards Kenneth A. Monroe, PE, MBA, CHC, PMP Director - Engineering Learning Objectives z At the conclusion of this presentation,

More information

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers,

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers, NFPA CODE TESTING & INSPECTION Requirements & Recommendations for Licensed Florida Hospitals, Ambulatory Surgery Centers, ICF/IID Healthcare, & In-patient Hospice Facilities per NFPA Life Safety Code 101

More information

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #5

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #5 THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #5 AGENDA: Ambulatory Health Care & Business Occupancies Definitions / Examples Mixed & Contiguous Occupancies Ambulatory Health Care &

More information

FIRE SAFETY SURVEY REPORT AMBULATORY SURGICAL CENTERS (ASC) & END STAGE RENAL DISEASE (ESRD) MEDICARE

FIRE SAFETY SURVEY REPORT AMBULATORY SURGICAL CENTERS (ASC) & END STAGE RENAL DISEASE (ESRD) MEDICARE DEPARTMENT OF HEALTH AND HUMAN SERVICES CENTERS FOR MEDICARE & MEDICA SERVICE Form Approved OMB Exempt FIRE SAFETY SURVEY REPORT AMBULATORY SURGICAL CENTERS (ASC) & END STAGE RENAL DISEASE (ESRD) MEDICARE

More information

NFPA 101 Life Safety Code Culture change 2012

NFPA 101 Life Safety Code Culture change 2012 NFPA 101 Life Safety Code Culture change 2012 Produced by Kansas Fire Marshal April, 2012 On March 9, 2012 Centers for Medicare & Medicaid Services implements a policy where they have formally adopted

More information

THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #4

THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #4 THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #4 WELCOME Moderator: Richard Schieferdecker support.webinato.com Audio 1 QUESTIONS How To Ask a Question: POLLING There will be occasional

More information

Demystifying Power Tap Use in Healthcare Settings John Garbarino Sr. Marketing Manager, Commercial/Industrial Leviton Manufacturing Co.

Demystifying Power Tap Use in Healthcare Settings John Garbarino Sr. Marketing Manager, Commercial/Industrial Leviton Manufacturing Co. Demystifying Power Tap Use in Healthcare Settings John Garbarino Sr. Marketing Manager, Commercial/Industrial Leviton Manufacturing Co. Product Safety Standards Nationally Recognized Testing Laboratory

More information

4/18/2017. *2012 edition of NFPA 99 has gone through a major overhaul. *This document is now a Code.

4/18/2017. *2012 edition of NFPA 99 has gone through a major overhaul. *This document is now a Code. Carsten Lunde, ASSE 6050 Instructor April 20, 2017 Carsten s Yearly Analysis, Inc. Any opinions expressed verbally by the speaker before you and all text in this presentation should be considered the speakers

More information

Developing a Healthcare Facility Fire Door Inspection Program

Developing a Healthcare Facility Fire Door Inspection Program Developing a Healthcare Facility Fire Door Inspection Program WELCOME Moderator: Richard Schieferdecker support.webinato.com Audio QUESTIONS How To Ask a Question: 1 POLLING There will be occasional interactive

More information

Standards Revisions Related to Life Safety Code Update

Standards Revisions Related to Life Safety Code Update Prepublication Issued Requirements The Joint Commission has approved the following revisions for prepublication. While revised requirements are published in the semiannual updates to the print manuals

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 75 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Type Memo Tag FED - K0100 - General Requirements - Other Title General Requirements - Other General Requirements - Other List in the REMARKS

More information

Medical Gas Inspections and Maintenance Programs. HESNI Annual Conference NIU Conference Center May 10-11, 2018 Presented by Mathis Carlson

Medical Gas Inspections and Maintenance Programs. HESNI Annual Conference NIU Conference Center May 10-11, 2018 Presented by Mathis Carlson Medical Gas Inspections and Maintenance Programs HESNI Annual Conference NIU Conference Center May 10-11, 2018 Presented by Mathis Carlson Mathis Carlson I have worked for the last 15+ years in the Medical

More information

Building Codes & Standards for Healthcare. Healthcare Construction Certificate - Level 1

Building Codes & Standards for Healthcare. Healthcare Construction Certificate - Level 1 Building Codes & Standards for Healthcare Building Codes and Standards AHJs Codes Defend in Place Walls Sprinklers Fire Alarm Important Dates for Healthcare Facilities 7/5/16 NFPA Life Safety Code 101

More information

The Surveyor s Perspective. Understanding How The Joint Commission Surveyors Conducts Surveys

The Surveyor s Perspective. Understanding How The Joint Commission Surveyors Conducts Surveys The Surveyor s Perspective Understanding How The Joint Commission Surveyors Conducts Surveys Tim Markijohn MBA\MHA, CHFM, CHE Field Director, Life Safety Learning Objectives At the conclusion of this presentation,

More information

Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates

Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates Issued September 20, 2017 Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates Environment of Care (EC) Chapter Critical Access Hospital (CAH) Accreditation Program

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 100 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS CFR Type Memo Tag FED - K9999 - FINAL OBSERVATIONS Title FINAL OBSERVATIONS CFR Type Memo Tag FED - KA100 - General Requirements - Other

More information

Ohio Department of Health NFPA 2012 Life Safety Code Tips Sheet

Ohio Department of Health NFPA 2012 Life Safety Code Tips Sheet Ohio Department of Health NFPA 2012 Life Safety Code Tips Sheet This document is used for frequently cited Life Safety Code violations. This is not an all-inclusive list and is intended for reference only.

More information

PRINTED: 06/09/2017 FORM APPROVED CENTERS FOR MEDICARE & MEDICAID SERVICES OMB NO (X2) MULTIPLE CONSTRUCTION A. BUILDING 03 - A BUILDING

PRINTED: 06/09/2017 FORM APPROVED CENTERS FOR MEDICARE & MEDICAID SERVICES OMB NO (X2) MULTIPLE CONSTRUCTION A. BUILDING 03 - A BUILDING SUMMARY PROVER'S PLAN OF CORRECTION K 000 INITIAL COMMENTS K 000 A Life Safety Code Survey was conducted by the State Fire Marshal beginning on May 9th, 2017 and ending on May 10th, 2017. Adair Acute Care

More information

GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES

GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES [B] APPENDIX SR GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES The provisions contained in this appendix are adopted by the Building Codes Division of the State of Oregon SECTION SR101

More information

C. None (No sprinkler system) K3 E. NUMBER OF BEDS CERTIFIED FOR MEDICAID

C. None (No sprinkler system) K3 E. NUMBER OF BEDS CERTIFIED FOR MEDICAID DEPARTMENT OF HEALTH AND HUMAN SERVICES CENTERS FOR MEDICARE & MEDICAID SERVICES FIRE SAFETY SURVEY REPORT - 2000 LIFE SAFETY CODE Intermediate Care Facilities for the Mentally Retarded LARGE PART I Figure

More information

27th Annual AHCA Seminar

27th Annual AHCA Seminar 27th Annual AHCA Seminar NFPA 99 2012 Edition Overview and Discussion Presented by James Peterkin, PE Sr. Fire Protection Engineer Heery International Monday September 26, 2011 Disclaimer Not Speaking

More information

TOPICS IN CODE ENFORCEMENT

TOPICS IN CODE ENFORCEMENT TOPICS IN CODE ENFORCEMENT CAHED SE DISTRICT MEETING FEBRUARY 17, 2017 Mark Jelinske Cator, Ruma, and Associates mjelinske@catorruma.com 303-462-8475 TALKING POINTS Conducting Surveys on NFPA 2012 as of

More information

Procedure DESCRIPTION/OVERVIEW

Procedure DESCRIPTION/OVERVIEW Applies To: UNMH Responsible Department: Life Safety Revised: 07.08.16 Procedure Patient Age Group: (X ) N/A ( ) All Ages ( ) Newborns ( ) Pediatric ( ) Adult DESCRIPTION/OVERVIEW To assure the safety

More information

NFPA 101 and NFPA 99, 2012 Editions Code Update. where art meets engineering

NFPA 101 and NFPA 99, 2012 Editions Code Update. where art meets engineering NFPA 101 and NFPA 99, 2012 Editions Code Update where art meets engineering Austin Dallas Denver Houston Kansas City Miami Nashville Phoenix Richmond Washington DC NFPA 101 and NFPA 99 where art meets

More information

Top (15) Life Safety Code Deficiencies and Tips for Compliance (10/01/2011 thru 02/22/2012)

Top (15) Life Safety Code Deficiencies and Tips for Compliance (10/01/2011 thru 02/22/2012) 1. K62 Automatic Sprinkler Systems - Automatic sprinkler systems are continuously maintained in reliable operating condition and are inspected and tested periodically. 18.7.6, 19.7.6, 4.6.12, NFPA 13,

More information

UPDATE. The Healthcare Environment. George Mills, Sr. Engineer Standard Interpretation Group The Joint Commission. Copyright, The Joint Commission

UPDATE. The Healthcare Environment. George Mills, Sr. Engineer Standard Interpretation Group The Joint Commission. Copyright, The Joint Commission 2010 UPDATE The Healthcare Environment George Mills, Sr. Engineer Standard Interpretation Group The Joint Commission Human Factor Trust Report Improve TRUST REPORT IMPROVE Communication SIG Engineering

More information

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES [B] APPENDIX SR GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES The provisions contained in this appendix are adopted by the Building Codes Division of the State of Oregon. SECTION SR101 GENERAL

More information

UNIVERSITY OF TOLEDO

UNIVERSITY OF TOLEDO UNIVERSITY OF TOLEDO SUBJECT: INTERIM LIFE SAFETY MEASURES AND INFECTION Procedure No: LS-08-008 CONTROL PROCEDURE STATEMENT Interim life safety and infection control measures will be implemented to protect

More information

NFPA 99 for Facility Managers

NFPA 99 for Facility Managers NFPA 99 for Facility Managers Application to Existing Facilities October 13, 2015 Jonathan Hart: Senior Fire Protection Engineer Learning Objectives Review the layout of NFPA 99 Understand the application

More information

Interim Life Safety Measures. Healthcare Construction Certificate - Level 1

Interim Life Safety Measures. Healthcare Construction Certificate - Level 1 Interim Life Safety Measures Purpose of Interim Life Safety Management BASIC SAFETY: During renovations projects in healthcare occupancies, the basic level of protection for the occupants must be maintained

More information

What's New January 2017 Release

What's New January 2017 Release Comprehensive Accreditation Manual for What's New January Release What s New is intended to help you understand the substantive changes in the most recent E-dition release. Please refer to the following

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 92 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Type Memo Tag FED - K9999 - FINAL OBSERVATIONS Title FINAL OBSERVATIONS Type Memo Tag FED - KA100 - General Requirements - Other Title

More information

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge. 2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge. Exception: Manual fire alarm boxes are not required where the building is

More information

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing. 9/20/2016 2:27 PM Second Revision No. 5006-NFPA 101-2016 [ Section No. 3.3.56 ] 3.3.56 Delayed Action Closer. Self-closing device that incorporates a delay prior to the initiation of closing. Mechanical

More information

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011 HCFMO Harris County Fire Marshal M.S. Montgomery Fire Marshal FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011 EFFECTIVE JANUARY 1, 2007 These guidelines

More information

CMS CATEGORICAL WAIVER CHECKLIST Page 1 of 7 Waiver Topic, description & location:

CMS CATEGORICAL WAIVER CHECKLIST Page 1 of 7 Waiver Topic, description & location: FACILITY NAME: CMS CATEGORICAL WAIVER CHECKLIST Page 1 of 7 Waiver Topic, description & location: CITY: If the facility desires to use any of the CMS categorical waivers listed below, it should follow

More information

10/28/2015. Enjoy Your TJC Survey. Bill H. McCully CHFM SASHE. Senior Consultant MSL Healthcare Partners. MSL Healthcare Partners, 2015 PREPARATION

10/28/2015. Enjoy Your TJC Survey. Bill H. McCully CHFM SASHE. Senior Consultant MSL Healthcare Partners. MSL Healthcare Partners, 2015 PREPARATION Enjoy Your TJC Survey Bill H. McCully CHFM SASHE Senior Consultant MSL Healthcare Partners PREPARATION 1 Top Eight Most Cited Standards (George Mills) EC News May 2015 Top Citations EC.02.06.01 56% EC.02.05.01

More information

FACILITY MANAGEMENT DEFICIENCIES IN CRITICAL ACCESS HOSPITALS (CAH)

FACILITY MANAGEMENT DEFICIENCIES IN CRITICAL ACCESS HOSPITALS (CAH) FACILITY MANAGEMENT DEFICIENCIES IN CRITICAL ACCESS HOSPITALS (CAH) Presented by: Alise Howlett, Assoc. AIA, CFPE, CHFM Standards Advisor, EM/PE/LS HFAP A better healthcare survey experience 1 FREQUENT

More information

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment M E M O R A N D U M TO: FROM: NFPA Technical Committee on Building Services and Fire Protection Equipment Linda MacKay DATE: November 10, 2009 SUBJECT: NFPA 5000 A2011 ROP Letter Ballot Final Results The

More information

FACILITY MANAGEMENT DEFICIENCIES IN ACUTE CARE SETTINGS

FACILITY MANAGEMENT DEFICIENCIES IN ACUTE CARE SETTINGS FACILITY MANAGEMENT DEFICIENCIES IN ACUTE CARE SETTINGS Presented by: Alise Howlett, Assoc. AIA,CFPE, CHFM Standards Advisor, EM/PE/LS HFAP A better healthcare survey experience 1 FREQUENT PHYSICAL ENVIRONMENT

More information

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline Moreno Valley Fire Department Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: May 8, 2017 Alarm & Signaling Systems PURPOSE Fire alarm and signaling systems are designed to

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 51 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS CFR Type Memo Tag FED - K0130 - MISCELLANEOUS Title MISCELLANEOUS OTHER LSC DEFICIENCY NOT ON 2786 FED - K9999 - FINAL OBSERVATIONS Title

More information

Fire & Life Safety Code Compliance. Common Safety Deficiencies and Tips for Compliance for Long Term Care and Skilled Nursing Facilities

Fire & Life Safety Code Compliance. Common Safety Deficiencies and Tips for Compliance for Long Term Care and Skilled Nursing Facilities Fire & Life Safety Code Compliance Common Safety Deficiencies and Tips for Compliance for Long Term Care and Skilled Nursing Facilities LTC, Skilled Nursing Facilities COMMON LIFE SAFETY DEFICIENCIES

More information

Beth Israel Deaconess Medical Center BIDMC Manual

Beth Israel Deaconess Medical Center BIDMC Manual Beth Israel Deaconess Medical Center BIDMC Manual Title: Life Safety/Fire Safety Management Plan Policy #: EOC-04 Purpose: The BIDMC Life Safety Management Plan defines the program to minimize the probability

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 21 ST - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Statute or Rule Type Memo Tag These guidelines are meant solely to provide guidance to surveyors in the survey process. ST - K0300 - Other

More information

10/25/2018. Facilitators. Emergency Preparedness &Life Safety Code for Administrators. Participant Guide

10/25/2018. Facilitators. Emergency Preparedness &Life Safety Code for Administrators. Participant Guide Emergency Preparedness &Life Safety Code for Administrators 1 Participant Guide Emergency PreparednessHandouts Graphic Organizer Sample Checklist for Emergency Preparedness Regulation Compliance Crosswalk

More information

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement of 43 10/20/2015 4:02 PM First Revision No. 2035-NFPA 101-2015 [ Global Input ] To 14.3.4.4.1, add an item (4) to read: (4) Carbon monoxide detectors shall be installed centrally located within occupiable

More information

Public Safety in the Healthcare Facility

Public Safety in the Healthcare Facility CABMET Study Group Public Safety in the Healthcare Facility Matt Baretich Baretich Engineering Fort Collins, Colorado mfb@baretich.com Slide 1 Public Safety: 15% of CBET Exam Electrical Chemical Radiation

More information

Changes in NFPA

Changes in NFPA Changes in NFPA 72-2002 2002 Oregon Fire Code Committee November 25, 2003 Michael B. Baker, SET Automatic Fire Alarm Association MikeBaker@afaa.org 2003 Michael B. Baker 1 Table of Contents 1. Administration

More information

Measures (ILSM) Process

Measures (ILSM) Process Managing the Interim Life Safety Measures (ILSM) Process 1 A Program for The Texas Association of Healthcare Facility Management Monday, April 30, 2012 Robert H. Bartels, CHFM CHSP CHEP SASHE President,

More information

SAF-BCF SECOND REVISIONS WITH STATEMENTS

SAF-BCF SECOND REVISIONS WITH STATEMENTS Page 196 of 331 32.2.1.3 ] Second Revision No. 153-NFPA 101-2013 [ New Section after 32.2.1.4 Multiple-Level Buildings. For purposes of applying requirements of this chapter that utilize the term level

More information

First Revision No NFPA [ Section No ]

First Revision No NFPA [ Section No ] of 45 10/21/2015 8:54 AM First Revision No. 3501-NFPA 101-2015 [ Section No. 3.3.190.1 ] 3.3.196.1* Ambulatory Health Care Occupancy. An occupancy used to provide services or treatment simultaneously to

More information

The Physical Environment Portal: Module 5, LS Leadership

The Physical Environment Portal: Module 5, LS Leadership The Physical Environment Portal: Module 5, LS.02.01.10 - Leadership Fire Safety: Background Fire safety impacts both the lives of the occupants and the physical structures. In the early 1900 s many buildings

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 75 ST - K0000 - Initial Comments Title Initial Comments Statute or Rule Type Memo Tag These guidelines are meant solely to provide guidance to surveyors in the survey process. ST - K0001 - OTHER

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 41 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS CFR Type Memo Tag FED - K0011 - LIFE SAFETY CODE STANDARD If the building has a common wall with a nonconforming building, the common

More information