XVUC29 Ø60mm LED unit - steady/flash/rotate, multicolor unit, IP65, 24VAC/DC

Size: px
Start display at page:

Download "XVUC29 Ø60mm LED unit - steady/flash/rotate, multicolor unit, IP65, 24VAC/DC"

Transcription

1 Characteristics Ø60mm LED unit - steady/flash/rotate, multicolor unit, IP65, 24VAC/DC Product availability : Stock - Normally stocked in distribution facility Price* : USD Main Range of product Product or component type Beacon or indicator bank unit type Mounting diameter Component name Light source Light source colour Device application Complementary Signalling type Assembly style Aug 23, 2018 Harmony XVU Modular tower light LED unit 2.36 in (60 mm) XVU LED multi-colour Blue Green Red White Yellow Amber Automotive Machine tools Packaging machine Flashing Steady Blinking Rotating Customer assembly, up to 5 units Up to 4 units with buzzer Material PC (polycarbonate) V-0 flame retardant conforming to UL 94 PC (polycarbonate) V-2 flame retardant conforming to UL 94 [Us] rated supply voltage Power dissipation in W Current consumption Flashing frequency 24 V AC/DC <= 1.5 W <= 70 ma 1 Hz blinking 0.23 Hz slow flashing 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

2 Signalling type Length Product weight 7.26 Hz fast flashing 2.33 Hz slow rotating 3.3 Hz fast rotating Steady/Blinking/Flashing/Rotating 1.97 in (50 mm) 0.14 lb(us) (0.064 kg) Environment Product certifications Ambient air temperature for storage IP degree of protection Ambient air temperature for operation Vibration resistance CE CSA RoHS UL F ( C) IP F ( C) 2 gn Ordering and shipping details Category XVU TOWER LIGHTS Discount Schedule XV GTIN Nbr. of units in pkg. 1 Package weight(lbs) Returnability Y Country of origin ID Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Green Premium product Compliant - since Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Product environmental profile Product end of life instructions California proposition 65 Available Available WARNING: This product can expose you to chemicals including: Substance 1 Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm More information For more information go to 2

3 Dimensions Drawings Illuminated LED Unit Dimensions 3

4 Mounting and Clearance Modular Tower Lights Mounting Drawing Part number Part name A1 - Top cover - Top cover (Silver) A2 XVUC9S Buzzer unit XVUC9SQ Buzzer unit (Silver) A3 XVUC23 Green LED unit XVUC24 XVUC25 XVUC26 XVUC27 XVUC28 Red LED unit Orange LED unit Blue LED unit White LED unit Yellow LED unit A4 Multi-LED unit A5 P Multi-LED unit, Pulse signal A6 XVUC9V Sound unit A7 XVUC9VP Sound unit, Pulse signal 4

5 Drawing Part number Part name A8 XVUC020 Extender XVUC020Q Extender (Silver) A9 XVUC21B DC body XVUC21BQ DC body (Silver) A10 XVUC21M AC body NPN XVUC21MP XVUC21MQP AC body PNP AC body PNP (Silver) A11 XVUZ06 Flexible option A12 XVUZ01 Fixing Unit - Direct mounting (3 pins) XVUZ01Q XVUZ03 XVUZ04 Fixing Unit - Direct mounting (Silver,3 pins) Fixing Unit - Direct mounting (2 pins) Fixing Unit - Direct mounting (4 pins) A13 XVUZ02 Fixing Unit - Plate with Pole (100 mm) XVUZ02Q XVUZ400 XVUZ800 Fixing Unit - Plate with Pole (100 mm, Silver) Fixing Unit - Plate with Pole (400 mm) Fixing Unit - Plate with Pole (800 mm) A14 XVUZ05 Fixing Unit - Plate with adjustment pole ( mm) A15 XVUC43 Green LED unit, Flash XVUC44 XVUC45 XVUC46 XVUC47 XVUC48 Red LED unit, Flash Orange LED unit, Flash Blue LED unit, Flash White LED unit, Flash Yellow LED unit, Flash A16 XVUZ100T Fixing Unit - Metal bracket with pole (100 mm) XVUZ250T Fixing Unit - Metal bracket with pole(250 mm) XVUZ400T Fixing Unit - Metal bracket with pole (400 mm) A17 XVUZ12 Fixing plate for use on vertical support - black 5

6 Connections and Schema Illuminated Units, Multi-LED and Audible Units Wiring (A) Fixing Unit (1) Dimensions of Wiring size (2) Push-in Wire Connectors (3) Fuse : 2A,250V (4) Fuse : 0.5A,125V (5) Modular Tower Lights 24V AC/DC (6) Modular Tower Lights V AC L1 to L5 : Illuminated LED Units 6

TSXAEY1614C analog input module - 16 inputs - thermocouple - 16 bits

TSXAEY1614C analog input module - 16 inputs - thermocouple - 16 bits Characteristics analog input module - 16 inputs - thermocouple - 16 bits Product availability : Stock - Normally stocked in distribution facility Price* : 5684.45 USD Main Range of product Product or component

More information

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8 Characteristics photo-electric sensor - XUM - multi - Sn 0..10m - 12..24VDC - M8 Main Range of product Series name Electronic sensor type Sensor name Sensor design Detection system Material Type of output

More information

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12 Characteristics photo-electric sensor - XUX - multi - Sn 0..40m - 12..24VDC - M12 Complementary Enclosure material Lens material Maximum sensing distance Output type Add on output Status LED [Us] rated

More information

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m Characteristics photo-electric sensor - XUB - thru beam - laser - Sn 100m - 12..24VDC - cable 2m Buy online Complementary Enclosure material Lens material Blind zone Output type Status LED [Us] rated supply

More information

Half-Dome. the Design-Tower. Compact

Half-Dome. the Design-Tower. Compact the Design-Tower 81 Compact 82 compact signal towers Visual-audible LED signal tower system in semicircular design Modern signal tower design Available to order pre-configured or with customised tower

More information

Multi-Gas-Controller MGC2

Multi-Gas-Controller MGC2 Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants

More information

2 Tones to select LU7

2 Tones to select LU7 LU PATLITE s LU & LU Series signal towers deliver the advantages of superior LED technology, innovative design, and the convenience of modular assembly with only basic modular components to meet just about

More information

Pilot devices Stacklights Signal beacons

Pilot devices Stacklights Signal beacons Pilot devices Fast mounting of signal elements using bayonet fixing Easy changing of bulbs for each module without tools Up to 10 light elements possible with 2-sided mounting bracket Flexibility of signal

More information

Auer - Signal tower ECO Ø70 mm modular

Auer - Signal tower ECO Ø70 mm modular products Panel Signalling Signal Towers - Auer Auer - Signal tower ECO Ø70 mm modular Modular system with bayonet fitting for quick assembly LED or conventional filament lamp for cost sensitive applications

More information

New Beacon Series T & U

New Beacon Series T & U New Beacon Series T & U Beacon Series T LED steady/flashing beacons LED multi strobe beacons Steady beacons Light/Beacons options 1 Mounting options 2 Complete product LED steady/flashing beacon LED multi

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers 687 Optical Touch Switch SW-1 SERIES Related Information General terms and conditions... F-3 General precautions... P.1595 PHOTO PHOTO Conforming to OSHA / ANSI Listing MEASURE panasonic.net/id/pidsx/global

More information

Conformity Approvals Rated insulation voltage Ui

Conformity Approvals Rated insulation voltage Ui GIOVENZANA INTERNATIONAL B.V. GENERAL CHARACTERISTICS ELECTRICAL CHARACTERISTICS CONTACT BLOCKS CAM SWITCHES Giovenzana International B.V., widely recognized as a leader in elevator technology and the

More information

PolyGard 2-channel Gas Controller MGC-03

PolyGard 2-channel Gas Controller MGC-03 PolyGard 2-channel Gas Controller MGC-03 DESCRIPTION Gas measuring and monitoring controller based on state-ofthe-art micro-technology with integrated buzzer for continuous monitoring of the ambient air

More information

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001 Throughbeam photoelectric sensors Dimensioned drawing 15m 1-3 V DC A 2 LS Throughbeam photoelectric sensors with high performance reserve in infrared light Robust metal housing with glass cover, protection

More information

Dräger PointGard 2100 Detection of toxic gases and vapours

Dräger PointGard 2100 Detection of toxic gases and vapours Dräger PointGard 2100 Detection of toxic gases and vapours The Dräger PointGard 2100 series is a self-contained gas detection system for the continuous area monitoring of toxic gases in ambient air PointGard

More information

Series M22 Signaling Beacons and Alarms

Series M22 Signaling Beacons and Alarms Series M22 Beacons and Alarms Signaling S I G N A L G E R Ä T E Signaling Solutions Loud and Clear M22 Panel Mount Signaling Beacons and Alarms from the Auer company are the perfect compliment to Sprecher

More information

Operations Manual. Motion Detector Module Model ZS10

Operations Manual. Motion Detector Module Model ZS10 Motion Detector Module Model ZS10 The must be referred to for correct installation. Failure to comply with the shall void all warranties and liabilities. Overview The ZS10 Motion Detector Module is an

More information

Mimic display driver, LED ribbon cable

Mimic display driver, LED ribbon cable Sinteso / Cerberus PRO Mimic display driver, LED ribbon cable FT2001-A1, F50F410 FDnet/C-NET mimic display driver and LED ribbon cable for the fire detection systems Sinteso FS20 and Cerberus PRO FS720.

More information

Door Release Power Supply

Door Release Power Supply www.protectingpeople.co.uk Door Release Power Supply Engineer / Installation Manual Document: VI55.1 Protecting People Printed : 04/03/2004-1 - Ventcroft Ltd Door Release Power Supply Engineer / Installation

More information

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon Sounders Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon Pg 185 186 187 188 189 190 191 Y03 1YA030207 1YA030203 1YA030205 YL030/24 A1:2002 YL030110/230 UL464 C22.2 No. M1983 BS

More information

Celebrating YEARS Manufacturers of Visual & Audible Signalling Devices. NEW Exd

Celebrating YEARS Manufacturers of Visual & Audible Signalling Devices. NEW Exd Celebrating 15 YEARS Manufacturers of Visual & Audible Signalling Devices 1998-2013 NEW Exd INTRODUCTION MOFLASH to the world of Based in Birmingham at the heart of Great Marine FM 558977 P P P P P P P

More information

Control and Annunciator Panels. Compact systems of signalling and control

Control and Annunciator Panels. Compact systems of signalling and control Control and Annunciator Panels Compact systems of signalling and control 56 Control and Annunciator Panels Technical features Body material: Polycarbonate V0/UL 9 - Colour: Black degree: IP0 Not replaceable

More information

10yr O2NE & Safe-Ox. User Manual

10yr O2NE & Safe-Ox. User Manual Analox Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK T: +44 (0)1642 711400 F: +44 (0)1642 713900 W: www.analox.net E: info@analox.net This support line is closed on UK public

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

APS-S/M Series. Polycarbonate Resin Square Type, 2-wire/3-wire DC System. Type. Proximity Sensor. Features

APS-S/M Series. Polycarbonate Resin Square Type, 2-wire/3-wire DC System. Type. Proximity Sensor. Features Sensor INFORMATI Series Features Polycarbonate Resin, -wire/-wire DC System - Front Surface / Upper Surface detection - s of different frequency are available for adjacent installation. - Conformity with

More information

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector. Color Mark Sensor Detects laminated or light-dispersing objects in stable operation without being influenced by mirror reflection. Double indication of the detection level and threshold level allows easy

More information

DTA. Motor thermistor relay. Benefits. Description

DTA. Motor thermistor relay. Benefits. Description DTA Motor thermistor relay Description DTA71 and are precise Motor thermistor monitoring relays. They can monitor up to 6 motor temperatures through the motor internal temperature. PTCs are connected in

More information

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V. Signaling Devices Acoustic Signaling Devices 28 Optical Signaling Devices 30 26 Signaling Devices Acoustic Signaling Devices Acoustic Signaling Devices MSS300-SA SG 200 DS 10 LSN/GLT GLT GLT GLT Operating

More information

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm VIMPEX Sounder Range Fire Alarms Banshee Electronic Sounders FlashDome EN 54-3 Evacuation Audible Alarm BS 5839-1 Beacons The range of sounders, beacons, sounder beacons and accessories represents the

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL Spectron Gas Control Systems GmbH Fritz-Klatte-Str. 8 65933 Frankfurt Germany Tel.: +49 69 38016-0 Fax: +49 69 38016-200 Email: info@spectron.de www.spectron.de 1 GES_K12_0915.docx

More information

DTA04. Motor thermistor relay. Benefits. Description

DTA04. Motor thermistor relay. Benefits. Description Motor thermistor relay Benefits High operating safety. The thresholds are determined by the Motor PTC. Beyond the specified temperature the output stops the motor/s. Save time and costs.there is no need

More information

SensaGuard TM Integrated Latch Installation Instructions

SensaGuard TM Integrated Latch Installation Instructions TM Integrated Latch Installation Instructions Certifications IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE Note: Refer to Technical Specifications for Certification information and ratings. 2 TM Installation

More information

Snifter ATEX22 VERSION. User Manual. Distributor

Snifter ATEX22 VERSION. User Manual. Distributor Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009 Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5

More information

Bulletin 855T 70 mm Control Tower Stack Lights

Bulletin 855T 70 mm Control Tower Stack Lights Bulletin 855T 70 mm Control Tower Stack Lights Light Modules Red Flashing Incandescent (Black Housing) 855T B 10 FN 4 a b c d a b c d Housing Color Voltage Light Module Type Lens Color Code Description

More information

Retro-reflective Sensing range: 0mm to 2000mm

Retro-reflective Sensing range: 0mm to 2000mm Retro-reflective : 0 to 2000 2000 2000 SORG2000B45NC1PKS SORG2000B45NC1NKS $ 195 $ 195 Output PNP, Sourcing NPN, Sinking Prograable: Prograable: Switch output (NO/NC) Switch output (NO/NC) Antivalent Antivalent

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web:  - The sensor is designed for frequent washdowns with a corrosion-resistant AISI316L stainless steel case IP69K rated, compliant to test environments like indicated by Diversey and Ecolab. However, all models

More information

VISUAL AND AUDIBLE SIGNALLING DEVICES

VISUAL AND AUDIBLE SIGNALLING DEVICES VISUAL AND AUDIBLE SIGNALLING DEVICES INDEX TECHNICAL INFORMATION Technical info see page 10 Ø 70 MULTI S 370 Tricolor see page 12 Quadricolor see page 13 Multicolor with integrated sound see page 13 Mounting

More information

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor

More information

Active Infrared Sensor OA-EDGE1/EDGE2. to the sensor module d4 = Distance from the pivot edge to the sensor module n = Number of sensor modules h

Active Infrared Sensor OA-EDGE1/EDGE2. to the sensor module d4 = Distance from the pivot edge to the sensor module n = Number of sensor modules h DETECTION AREA Active Infrared Sensor OA-EDGE1/EDGE Recommended installation position Leading edge d3 w Pivot edge W Door widt Mounting eigt / d Detection area widt d3 Distance from te leading edge to

More information

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes 50-120 1 General The heat exchanger control system is a control system for 380 W step motors

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

signaling solutions from auer signal

signaling solutions from auer signal Modular Series and Visual /Audible Series signaling solutions from auer signal Five Types of Interchangeable Simple Twist & Heavy Duty Illumination Components Release Modules Construction Modular Beacon

More information

LEAKSTOPPER 1 Single zone water leak detection system

LEAKSTOPPER 1 Single zone water leak detection system LEAKSTOPPER 1 Single zone water leak detection system WHAT DOES THE PRODUCT DO? The LeakStopper 1 detects the presence of water in environments where it is not supposed to be. Should water be detected

More information

LEAKSTOPPER RANGE Multizone water leak detection systems

LEAKSTOPPER RANGE Multizone water leak detection systems LEAKSTOPPER RANGE Multizone water leak detection systems WHAT DOES THE PRODUCT DO? The LeakStopper detects water leaks and instantly triggers an alarm to warn you. It is capable of monitoring between 2

More information

Contents. Security. Page

Contents. Security. Page Farnell Page 1213 Date: 21-08-06 time:19:37 Contents Page Alarm Sounders & Sirens 1215 Beacons 1218 CCD Cameras 1214 CCTV Camera Accessories 1215 Combined Sounders & Beacons 1221 Key /Accessories 1214

More information

Sonos-SB Siren/Beacon

Sonos-SB Siren/Beacon Sonos-SB Siren/Beacon Audible/optical signal transmitter compliant with EN 54-3 and EN 54-23 for fire alarm systems, in red and white. Wall mounting (category W) and ceiling mounting (category C) for indoor

More information

SOCH AUTOMATION AND POWER SOLUTION

SOCH AUTOMATION AND POWER SOLUTION EMERGENCY SERVICE INDUCTIVE COLOR CAPACITIVE CONTRAST METAL FACE REED SWITCH ANALOG Soch Automation And Power Solution Ware House (India) : Golden Enclives B-Block Siddeshwara Layout, Bengaluru, Karnataka-

More information

E3M-V. Mark Sensor. Applications

E3M-V. Mark Sensor. Applications Mark Sensor Detects laminated or light-dispersing objects in stable operation without being influenced by mirror reflection. Double indication of the detection level and threshold level allows easy grasp

More information

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver Power Distribution Unit for IP-NINJAR PDU-1209 User s Guide Ver. 1.0.0 Thank you for choosing this IDK product. To ensure the best performance of this product, please read this User s Guide fully and carefully

More information

Security - Warning Devices Audible & Visual

Security - Warning Devices Audible & Visual Security - Warning Devices Audible & Visual Page Beacons - Automotive... 3044 Bells... 3056 Beacons - Incandescent... 3043 Hooter... 3056 Beacons - LED... 3039 Peizo/Buzzers... 3050 Beacons - Rotating...

More information

Vacuum suction nozzle OVEM-...-1P/1N

Vacuum suction nozzle OVEM-...-1P/1N Vacuum suction nozzle OVEM-...-1P/1N Operating instructions (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com 8085608 2018-01b

More information

AO Annunciator Module

AO Annunciator Module General Specifications GS48C43Z01-00E-N AO-543-01 Annunciator Module GENERAL Figure 1 This module has two independent annunciator circuits. The circuits handle fault signals and operator actions (acknowledge,

More information

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

DEB71. Earth Leakage Monitoring Relay. Benefits. Description Earth Leakage Monitoring Relay Benefits Adjustable trip level. Adjustable leakage threshold from 30mA to 5A or from 300mA to 30A. 2 outputs. Two relay outputs provide, besides the alarm signal an additional

More information

2 General Application Photoelectric Sensors

2 General Application Photoelectric Sensors SMARTEYE PRO/PRO 2 General Application Photoelectric Sensors Self-Adjusting General Purpose Sensor www.ttco.com 800-237-0946 2-7 General Application Photoelectric Sensors 2 SMARTEYE PRO/PRO The SMARTEYE

More information

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen PolyGard Single Point Controller SPC-X3-XX for Toxic Gases and Oxygen DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor and

More information

General Purpose Photoelectric Sensor

General Purpose Photoelectric Sensor EZ-EYE 2 General Application Photoelectric Sensors General Purpose Photoelectric Sensor www.ttco.com 800-237-0946 2-37 General Application Photoelectric Sensors 2 EZ-EYE The EZ-EYE miniature photoelectric

More information

STRUCTURED LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED

STRUCTURED LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED SXP30 Series STRUCTURED LIGHT Projector product introduction The SXP30 Series Projector Light offers the most intense projected pattern offered from an LED. The 9mm² die size emits 9x the intensity as

More information

CONVENTIONAL AUDIBLE VISUAL

CONVENTIONAL AUDIBLE VISUAL Fast Installation, Safe Evacuation CONVENTIONAL AUDIBLE VISUAL www.kac.co.uk Setting the Standard with ENscape EN54-23 and how it affects you EN54-23 is a new European standard for Visual Alarm Devices

More information

Oxygen (O2) Single-Point Gas Detection System

Oxygen (O2) Single-Point Gas Detection System Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity

More information

Fan speed controller Type Saginomiya XGE

Fan speed controller Type Saginomiya XGE Data sheet Fan speed controller Type Saginomiya Fan speed controller stabilizes condensing pressure by changing condenser s fan speed. The controller reduces fan noise and saves energy in low ambient conditions.

More information

EN54-23 Beacons & Sounder Beacons

EN54-23 Beacons & Sounder Beacons EN54-23 Beacons & Sounder Beacons In a fire, everyone matters. Sonos Pulse and Nexus Pulse fire beacons ensure that all personnel are notified of fire emergencies. With Pulse Alert Technology, buildings

More information

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates 1 883 1883P01 1883P02 1859P04 QFM41.. AQF4150 AQF3153 Symaro Duct sensors for relative humidity and temperature with calibration certificates QFM41.. Operating voltage AC 24 V / DC 13.5...35 V Signal output

More information

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary

More information

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P Contents Description Data Sheet No. Page Overview P-1.50.001E 117-118 Technical Data SFI-plus P-1.50.002E-1, 2 119-120 Dimensions

More information

Lonworks Damper Interface Catalogue

Lonworks Damper Interface Catalogue Lonworks Damper Interface catalogue Release: 1.9 AUGUST 2017 Lonworks Damper Interface Catalogue Two Position, Three Position & Hot Smoke Fire Damper Interface This product forms part of a life safety

More information

EFBW series - BiWire Ultra control panel

EFBW series - BiWire Ultra control panel 4.2 Control panels and repeater panels EFBW series - BiWire Ultra control panel Eaton s new BiWire Ultra fire detection system is unlike any other standard conventional system as the panel, conventional

More information

Installation and user manual for the BiWire / Conventional Repeater Panel

Installation and user manual for the BiWire / Conventional Repeater Panel Panel EFBWCV-REPEATER Contents Introduction.... 3 Purpose... 3 The Panel.... 3 Indication Equipment (IE).... 3 Power Supply Equipment (PSE).... 4 System Wiring.... 5 Status Indications.... 5 Repeater I/O....

More information

NXM2G Installation and Operating Manual

NXM2G Installation and Operating Manual NXM2G-1001 MARCH 26, 2014 NXM2G Installation and Operating Manual (-1 UL version shown) 40VG This manual must be affixed on or adjacent to the boiler or kept with boiler operating manual or other information.

More information

Retroreflective sensor with polarization filter

Retroreflective sensor with polarization filter Dimensions 45 49 Receiver 23 27 74 56 Emitter 92 23 6 x 9 slots External thread (M30 x 1.5) 10 25 32 M12 x 1 Sens Delay IMER Model Number Retroreflective sensor with 4-pin, M12 x 1 connector Electrical

More information

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics... 14 Ex SOLENOID / ALARM DRIVER PRepower 5203B Table of contents Warnings... 16 Safety instructions... 17 Declaration of Conformity... 19 How to dismantle SYSTEM 5000... 20 Application... 21 Technical characteristics...

More information

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series DESCRIPTION The SZL-VL-S Series miniature-type limit switch is designed for use in applications where limited space is available. With IP67

More information

Fire Signalling. Signalling Solutions

Fire Signalling. Signalling Solutions Fire Signalling Signalling Solutions Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place.

More information

Overload relays. General descriptions. Configuration of the front

Overload relays. General descriptions. Configuration of the front Overload relays General descriptions Type MT, bimetal-style, overload relays are designed to protect AC circuits and motors against overloads, phase failure, long starting times and prolonged stalling

More information

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL. Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH Liquid Level Alarm 2.2 LOW Liquid Level Alarm 3. INSTALLATION...

More information

industrial, safety and security signalling products reference catalogue 2008/9

industrial, safety and security signalling products reference catalogue 2008/9 industrial, safety and security signalling products reference catalogue 2008/9... advanced warning technology www.deltadesign.co.uk www.eccogroup.com Innovation and quality from Europe s Xenon and LED

More information

Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices. Approved to EN54-3/EN54-23

Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices. Approved to EN54-3/EN54-23 Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices Approved to EN54-3/EN54-23 Setting the Standard EN54-23 and how it affects you EN54-23 is a new European standard for Visual Alarm

More information

FlexSQUARE Square shaped beacons

FlexSQUARE Square shaped beacons FlexSQUARE Square shaped beacons Size comparison Mini/Midi/Maxi Optical LED Permanent Light 5 LED Flashing Light 6 LED EVS 8 Your benefits The compact LED beacon is particularly versatile. With an IP67

More information

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models Series 9000 Description The Series 9000 photoelectric sensors are designed to perform in the harshest of industrial environments. The sensor will withstand 1200 psi high-pressure washdown and IP69K, which

More information

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL. Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH AND LOW LEVEL ALARM 2.2 PUMP DOWN CONTROLLER 2.3

More information

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016 LINETRAXX RCMA420 Residual current monitor for monitoring AC,

More information

Instructions for the fan motor control system, SILVER C

Instructions for the fan motor control system, SILVER C Instructions for the fan motor control system, SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units. The motor control system is

More information

COMPACT FLAME CONTROLLER CFC 100

COMPACT FLAME CONTROLLER CFC 100 COMPACT FLAME CONTROLLER CFC 100 TECHNICAL DESCRIPTION EDITION: TB CFC100 EN REV. 1 2012-03-07 IMPORTANT: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring

More information

Water separators MS-LWS, MS series

Water separators MS-LWS, MS series Water separators MS-LWS, MS series Water separators MS-LWS, MS series Product range overview MS series service units Type Size Pressure regulation range [bar] Grade of filtration [μm] Pneumatic connection

More information

General Specifications

General Specifications PHOTOSWITCH Photoelectric Sensors Series 6000 Description Series 6000 photoelectric sensors provide reliable general purpose sensing in a compact package. Each Series 6000 sensor has a single red output

More information

Industrial Signalling

Industrial Signalling Industrial Signalling Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place. Product Range

More information

INDICATOR LAMPS & LED REPLACEMENT LAMPS

INDICATOR LAMPS & LED REPLACEMENT LAMPS INDICATOR LAMPS & LED REPLACEMENT LAMPS M8 x 0.75 10.0 8.5 4.0 Chrome plated LED indicator 14.0 13.0 31.0 These indicators require a resistor to limit current. See note on page 53 for details. 55-432-0

More information

Motion Sensor. Specifications

Motion Sensor. Specifications Used for motion activated and dusk to dawn lighting control of flood lights, area lights, etc. Durable weatherproof construction utilizing infrared technology to sense temperature changes caused by movement

More information

IT AFEM. Table of Contents. Error! Table not allowed in footnote, endnote, header, footer, comment, or text box.

IT AFEM. Table of Contents. Error! Table not allowed in footnote, endnote, header, footer, comment, or text box. IT AFEM Table of Contents Error! Table not allowed in footnote, endnote, header, footer, comment, or text box. IT [Type text] B WWW.ITENCLOSURESYSTEMS.COM [Type text] TEKPAN AUTOMATIC FIRE EXTINGUISHING

More information

Rules for Classification and Construction Additional Rules and Guidelines

Rules for Classification and Construction Additional Rules and Guidelines VI Rules for Classification and Construction Additional Rules and Guidelines 7 Guidelines for the Performance of Type Approvals 7 Test Requirements for Statical Converters with Semi-Conductors Edition

More information

2 General Application Photoelectric Sensors

2 General Application Photoelectric Sensors SMARTEYE PRO/PRO REMOTE General Purpose Photoelectric Sensor 2 General Application Photoelectric Sensors 2-7 General Application Photoelectric Sensors 2 SMARTEYE PRO/PRO REMOTE The SMARTEYE PRO is not

More information

Key-Operated Switch GMA 41 / GMA 44 SW. Operation Manual

Key-Operated Switch GMA 41 / GMA 44 SW. Operation Manual Key-Operated witch GMA 41 / GMA 44 W Operation Manual Table of contents Page Introduction... 4 Key function... 4 Distinction of GMA 41/44 W models... 4 Relays... 5 P.C. boards of GMA 41/44 W... 7 Terminal

More information

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor 867 Safety Sensor SERIES Related Information General terms and conditions... F-3 General precautions... P.1595 guide... P.865~ Korea s S-mark... P.1602 PHOTO PHOTO Certified by NRTL Conforming to SEMI-S2

More information

Conventional Audible Visual Range

Conventional Audible Visual Range Conventional Audible Visual Range Visual Devices Non-Addressable Audible Visual Devices Base Sounder Honeywell s conventional audible visual devices operate over a wide input voltage range of 9 to 33VDC

More information

M2500 Engine Controller Installation Manual

M2500 Engine Controller Installation Manual M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...

More information

Fume Hood Operating Display Panel

Fume Hood Operating Display Panel Desigo TRA Fume Hood Operating Display Panel QMX3.P87 The Operating Display Panel (ODP) is the interface between the operator and the DXR Fume Hood Controller (FHC). LCD display for volume flow setpoint,

More information

Vaporproof White LED Light - 10 Watts - Non-Metallic - Corrosion Resistant Lumens

Vaporproof White LED Light - 10 Watts - Non-Metallic - Corrosion Resistant Lumens Vaporproof White LED Light - 10 Watts - Non-Metallic - Corrosion Resistant - 1050 Lumens Part #: VPLED-CRNM-LED10W Page: 1 Made in the USA The VPLED-CRNM-LED10W Vaporproof White LED Light from Larson Electronics

More information

TLS 500. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.1.

TLS 500. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.1. Installation and Operation Manual RoHS CEDES AG is certified according to ISO 9001: 200808 English Pages 2-12 110 605 130208 V 1.1 Contents 1. About this manual 2 1.1 Measurements 2 1.2 Related documents

More information

Membrane air dryers MS-LDM1, MS series

Membrane air dryers MS-LDM1, MS series Membrane air dryers MS-LDM1, MS series Membrane air dryers MS-LDM1, MS series Product range overview MS series service units Type Size Pressure regulation range [bar] Grade of filtration [μm] Pneumatic

More information