ACCURACY COMPLIANCE PEACE OF MIND

Size: px
Start display at page:

Download "ACCURACY COMPLIANCE PEACE OF MIND"

Transcription

1 FPA australia S ACCURACY COMPLIANCE PEACE OF MIND For more information visit

2 FPA Australia Logbooks In Stock For Immediate Delivery For Accuracy, Compliance and Peace-of-mind. Can your business afford non-compliance? In today s environment of strict regulatory frameworks in all states and territories regarding fire protection maintenance, you simply cannot afford to leave your work to chance. FPA Australia has created a suite of logbooks for maintenance recording and reporting activities in the fire protection industry. Complying fully with the appropriate service requirements of AS 1851 and AS , including keeping appropriate records is one way of demonstrating that you have met your legal obligations should a fire emergency situation arise or enforcement action be pursued. Meticulous planning has been undertaken to ensure that these documents accurately reflect the specific requirements of the standards and strive for best practice in reporting results to end users. Like many technical documents, AS1851 and AS are not always explicitly clear about exactly what data must be documented during routine service. However, FPA Australia s logbooks are specific about exactly what data must be documented. The professional design of these documents also assists technicians to complete the service records accurately and allows end users to fully understand the results, including any remedial actions required to ensure compliance. FPA Australia logbooks promote better fire protection and safety outcomes for the community and give peace of mind to technicians and building owners that appropriate inspection and testing is being undertaken in full and that the records of these activities are fully compliant with the relevant standards. For peace of mind, FPA Australia will periodically update all logbooks to reflect any changes to the Australian Standards including all amendments. Fire & Smoke Barriers & Construction Elements Summary Service Record Page 1 of 1 Work Order Item Required Actions Pass Fail N/A Item Required Actions Pass Fail N/A BARRIERS WALLS Table FIRE-PROTECTED STRUCTURAL MEMBERS Table Compare walls with approved design 2.1 Compare structural members with approved design Check condition of structural members including mechanical damage 1.2a & b Compare wall penetrations with approved design c Identify any unprotected or unsuitable wall penetrations deterioration, damage or integrity as applicable Inspect walls to ensure compartmentation is complete and FIRE-RATED GLAZING Table for any loss of fire resistance FIRE & SMOKE BARRIERS FLOORS Table Check for modifications to glazing that differ from the approved design 2.1 Compare floors with approved design 6.2 Check condition of glass 2.2a & b Compare floor penetrations with approved design 6.3 Check frame for damage and perimeter gaps are protected 2.2c Identify any unprotected or unsuitable floor penetrations 6.4 Check glazing seals are present and have not deteriorated Inspect floors for loss of fire resistance FIRE-PROTECTED AIR DUCTS Table FIRE & SMOKE BARRIERS CEILINGS Table Check for modifications to air ducts 3.1 Compare ceilings with approved design 7.2 Check drawings for details of fire protection system 3.2a & b Compare ceiling penetrations with approved design c Identify any unprotected or unsuitable ceiling penetrations deterioration or damage FIRE & SMOKE BARRIERS FIRE & SMOKE RATED ACCESS PANELS & HATCHES Table Compare access panels with approved design 4.2 Inspect access panel and perimeter seal for damage 4.3 Inspect and verify condition of access panel frame 4.4 Inspect screw-fixings (where applicable) 4.5 Inspect hinges and latches (where applicable) 4.6 Inspect for any interference with panel function AS/NZS Report identified deficiencies and amend schedule YEARLY SERICE SCHEDULE PENETRATIONS EQUIPMENT REGISTER Total number of penetrations Tally of s Checked Passed Failed RESULTS OF ROUTINE SERICE ACTIITIES Refer to equipment register for details of penetration location, protection type used and other relevant details ID ID ID Passive Fire & Smoke Systems Fire & Smoke Barriers & Construction Elements ID P P P P P P P P P P P P P ID Distribution of service record copies: owner/occupier/agent = original service provider = duplicate retained in this book = triplicate 1.0 April 2014 Work Order Item Required procedures Pass Fail N/A All previously identified corrective action attended to & Batteries (Clause.2) 1 Check battery electrolyte levels and inspect for leakage Emergency Evacuation Lighting for Buildings Central Systems Yearly Service Record Page 1 of 1 Inspect battery connections for corrosion and tighten where required 3 Apply appropriate preservative to exposed metal surfaces For lead acid batteries determine the electrolyte density for each cell (record in table below) Measure overall battery voltage and individual cell voltage (record in table below) Battery Charger Assembly (Clause.3) 6 Inspect all components for signs that may result in malfunction 7 Remove any dust or dirt from cubicle 8 erify battery voltage is consistent with system requirements 9 Check connections are tight 10 Check calibration of voltmeters 11 Check battery earth-fault detection system 12 Check battery low-voltage alarm Inverters (Clause.4) Measured Required 13 Inspect all components for signs that may result in malfunction Check that no power interruption has occurred in the preceding 16 hour period Check and verify d.c. input voltage and current is within tolerance limits of the inverter Check and verify a.c. output voltage and current is within the output tolerances of the inverter A A Item Required procedures Pass Fail N/A Inverters (Clause.4) Continued Distribution and Control Equipment (Clause.5) 17 Inspect all components for signs that may result in malfunction 18 Check connections are tight This record of service confirms that the Emergency Evacuation Lighting system has been inspected and maintained in accordance with AS and that the information on this service record is true and correct. This record does not infer compliance with 19 Remove any dust or dirt from within enclosures 20 Isolate coil circuits from a.c. supply and observe correct operation of lighting Emergency Luminaires and Exit Signs (Clause.6) Check operation of all emergency luminaires and exit signs (record results on lighting test record) 23 Indirect lighting systems check reflecting surfaces Indirect lighting systems where relevant, check beam direction is appropriate 25 Check system operates in correct relationship to normal lighting System Check Manual Discharge Test (Clause.7.1) Check battery charger changes to float charge mode manual boost-charge recharge System Check Automatic Discharge Test (Clause.7.2) 30 Conduct a manual discharge test for systems that incorporate manual discharge test facilities. Run test for required in-service duration Conduct an automatic discharge test for systems that incorporate automatic discharge test facilities QUEENSLAND BUILDINGS ONLY Maintenance complies with QDC, MP6.1 Name / Technician Signature Client Date Name Check calibration of voltmeters On completion of discharge test measure battery voltage and check it is within acceptable limits For d.c. reticulated systems measure max voltage at origin during boost charging Battery Test s Overall Cell 1 Cell 2 Cell 3 Cell 4 Cell 5 Cell 6 Electrolyte Density (Lead Acid Batteries) State of Charge (Lead Acid Batteries) Float Charge (All Batteries) Emergency Evacuation Lighting for Buildings Central Systems 22 Clean all light-emitting and reflecting surfaces

3 Item Actions required by Table Pass Fail N/A 1.1 Inspect audible and visual external alarms 1.2 Check replacement element and tool for MCP s (w/a) Item Actions required by Table Pass Fail N/A Inspect visual warning devices 2.4a Automatic discharge prevented 2.8 Test actuator circuit fault indictaion PERSONALISED BOOKS Fire Detection and Alarm Systems Monthly / Six Monthly Service Record Page 1 of 1 YOUR CONTACT DETAILS TO BE PLACED HERE Work Order Monthly Service Activities 2.2 Check local control station (LCS) 1.2 Check condition of CIE s 2.4 Test all discharge inhibit devices and confirm 1.3 Inspect battery enclosure 2.4b Stops and resets discharge sequence Simulate alarm and confirm indications and alarms function correctly Simulate alarm and confirm occupant warning system functions correctly 2.4c Activated visual indicator at LCS and FIP 2.4d Audible indication activated 2.4e Manual discharge switch continues to function 1.6 Confirm isolate/disable condition functions correctly 1.7 Test filament type visual indicators 1.8 Inspect zone block plan 1.9 Check presence of baseline data Six Monthly Service Activities Note: These activities relate to Special Hazards Systems ONLY 2.5 Test manual initiate function Confirm system inoperative visual warning devices 2.6 activate as a result of: 2.6a Operation of a service switch 2.6b Fault in the discharge actuator circuit 2.6c Operation of a lock-off valve Item Actions required by Table Pass Fail N/A 2.6d Operation of a manual inhibit switch 2.6e Isolation or fault in the fire detection system 2.1 Complete monthly service 2.7 Test and verify system operation and logic Fire Detection and Alarm Systems Associated / Connected Equipment Service Completed Yes No N/A If No or N/A, indicate reason below Monthly emergency warning system Monthly special hazards system Activity / System Failures Defect Identified 2.9 Test actuators operate correctly Item Defect Description / Corrective Action Required or Repairs Completed on notes page YOUR LOGO & CONTACT DETAILS TO BE PLACED HERE QUEENSLAND Maintenance complies with QDC, MP6.1 / Distribution of service record copies: owner/occupier/agent = original service provider = duplicate retained in this book = triplicate 1.0 April 2014 Personalised Logbooks 4-6 weeks delivery Make your professional service records stand out. Why not promote your business with your company logo? For a small set up fee you can have any A4 size FPA Australia logbook personalised featuring your logo and company details, ensuring that anyone who views your service records understands it is your business undertaking the vital fire protection work on site. Minimum quantity orders are required so speak to one of our Membership Services staff to learn more. When purchasing FPA Australia Logbooks, remember: FPA Australia vouchers can be used towards purchases within the Sales Centre, including logbooks Fire Protection Accreditation Scheme () Recognised Businesses receive an extra 10% off all logbook prices Corporate member rates apply for all FPA Australia Organisation and Corporate members More information about FPA Australia s suite of logbooks and personalised options can be found at To discuss any information in this brochure and to learn more about how FPA Australia logbooks can benefit your business, please call

4 Work Order System DP DW PA Additional Actions Dry Pipe Systems ONLY As required by Table Being Serviced Dry Pipe Deluge / Water Spray Pre-Action Item Actions required Pass Fail N/A Activities common to ALL systems 1.3 Check desiccant Item Actions required by Table , & Pass Fail N/A 1.4 Check oil level 1.8 Drain air receiver condensate DP Additional Actions Deluge / Water Spray Systems ONLY As required by Table DW Complete monthly wet pipe actions PA Check oil level and regulator DP Inspect and test electrical detection (where fitted) DW Check pressure gauge readings (record in table below) PA Check detector sprinkler line (where fitted) DP Cut-in () DW erify air compressor 1.7 Test solenoid valve(s) PA operating pressures Cut-out () Additional Actions Pre-Action Systems ONLY As required by Table DP DW erify low air pressure Activation 1.3 Check oil level and regulator (where fitted) PA alarms Pressure () 1.4 Inspect and test electrical detection DP DW Conduct alarm test 1.6 Check Nitrogen supply Cylinder (where fitted) Pressure () PA Test solenoid valve(s) Pressure Readings Air pressure gauge reading (Dry Pipe) Pilot line (Deluge / Water Spray) Supervisory air pressure (Pre-Action) Diaphragm line (Deluge/ Water Spray & Pre-Action) Below Stop alve (Deluge/ Water Spray & Pre-Action) Activity / System Failures Item Defect Description / Corrective Action Required or Repairs Completed Defect Identified on notes page / Distribution of service record copies: owner/occupier/agent = original service provider = duplicate retained in this book = triplicate LB2B 1.0 April 2014 Work Order Pumpset Item Actions required by Table Pass Fail N/A Hydrant Sprinkler Hose Reel 3.8 Service Pumpset Pumpset ID 3.8a/b/c Replace engine oil & filter 3.8c Check fuel condition Six Monthly Service Activities for Hose Reel and Pressure Maintenenace / Jacking Pumpsets Item Actions required by Table Pass Fail N/A 3.8d/e/f Inspect cooling hoses, flush and pressure test cooling system 3.8g Check cooling system pressure reducing valves 3.8h Service heat exchanger strainers 6.1 Complete monthly service 3.8i Service other items (manufacturers requirements) 6.2 erify hydro-pneumatic accumulator pressure 3.8 Inspect pump / driver coupling, grease jump bearings and Six Monthly Service Activities for Main Fire Pump (Diesel) j/k/l/m replace bearing and gearbox oil Item Actions required by Table Pass Fail N/A 3.4 Check condition of all batteries 2.1 Complete monthly service Date last replaced Check hydro-pneumatic accumulator and record air pressure (where fitted) erify condition of 3.6 control batteries or: Load Current (A) Yearly Service Activities Final oltage () Item Actions required by Table Pass Fail N/A 3.7 Test battery Start battery charger () charger Controller battery charger () 3.1 Complete monthly and six-monthly service 3.10 Check Non-return valves 3.2 Conduct annual full flow test and load test (Record all results in Electric Load and Flow Test Table next tab) 3.11 Check pipework for corrosion 3.9a Inspect heavy current carrying contacts 3.12 Test and verify operation of pressure-relief valve 3.9b/c/d Inspect pump / driver coupling, grease pump and motor bearings and replace bearing oil 3.13 Restore pumpsets 3.4 Check condition of all batteries 3.14 Test engine overspeed Check engine start Last replaced 3.15 Test and verify duty head 3.5 batteries are less than 2 years old 3.16 Test and verify remote start/stop function New battery installed Activity / System Failures Item Defect Description / Corrective Action Required or Repairs Completed Defect Identified on notes page Maintenance complies with QDC, MP6.1 QUEENSLAND / Distribution of service record copies: owner/occupier/agent = original service provider = duplicate retained in this book = triplicate LB3B 1.0 April 2014 Work Order Item Actions required by Table Pass Fail N/A Item Actions required by Table Pass Fail N/A erify water supply stop valve 1.10b position indicators 1.1 Check control valve assembly is unobstructed erify each valve monitor indicates 1.10c at CIE 1.2 Check spare sprinklers and spanner are available 1.11 Record and verify system pressure gauge readings before alarm function test (record in table below) 1.3 Check signage for damage, legibility and location 1.12 Conduct alarm function test and verify time of operation of 1.4 Check fire brigade booster connection is operational gong(s) (record in table below) 1.5 Check main stop valves and alarm 1.13 erify alarm signal operation cocks are open, secured and labelled Check pump starting devices are open 1.14 Check operation of strobe indicators 1.6 and secured Record and verify system pressure gauge readings after Check pressure switches alarm function test (record in table below) 1.8 Check alarm signalling equipment (ASE) 1.19 Check foam concentrate levels 1.9 Check sprinkler system interface status Test automatic and manual pump of devices 1.16 & starting devices in accordance with Auto Manual 1.10a erify water supply stop valves are 1.17 item 1.13 and 1.17 of Table open and secured Record results in pumpset logbook. Alarm function test results Installation pressure before test 1.11 Time to operation of alarm gong 1.12b Secs Installation pressure after test 1.15 Pressure readings 1.15 Location 1 Location 2 Location 3 Location 4 Associated / Connected Equipment Service Completed Yes No N/A If No or N/A, indicate reason below Below Stop alve Monthly pumpset Water Supply 1 Monthly water storage tank (Item 1.18) Water Supply 2 Monthly CIE Activity / System Failures Item Defect Description / Corrective Action Required or Repairs Completed Defect Identified on notes page / Distribution of service record copies: owner/occupier/agent = original service provider = duplicate retained in this book = triplicate LB2A 1.0 April 2014 Work Order Pumpset Hydrant Sprinkler Hose Reel Yearly Service Activities Item Actions required by Table Pass Fail N/A Pumpset ID Six Monthly Service Activities for Main Fire Pump (Electric) 3.1 Complete monthly and six-monthly service Item Actions required by Table Pass Fail N/A Conduct annual full flow test and load test (Record all 3.3 results in Electric Load and Flow Test Table next tab) 3.9a Inspect heavy current carrying contacts 2.1 Complete monthly service 3.9b/c/d Inspect pump / driver coupling, grease pump and motor bearings and replace bearing oil 2.2 Check alternative power supplies 3.4 Check condition of all batteries Check hydro-pneumatic accumulator and record air pressure (where fitted) Date last replace Six Monthly Service Activities for Hose Reel and Pressure Maintenenace / erify condition of Jacking Pumpsets 3.6 control batteries or: Load current (A) Item Actions required by Table Pass Fail N/A Final oltage () 3.7 Test battery charger Controller battery charger () 6.1 Complete monthly service 3.10 Check Non-return valves 6.2 erify hydro-pneumatic accumulator pressure 3.11 Check pipework for corrosion 3.12 Test and verify operation of pressure-relief valve 3.13 Restore pumpsets 3.15 Test and verify duty head 3.16 Test and verify remote start/stop function Activity / System Failures Item Defect Description / Corrective Action Required or Repairs Completed Defect Identified on notes page / Distribution of service record copies: owner/occupier/agent = original service provider = duplicate retained in this book = triplicate LB3A 1.0 April 2014 S LB2A Automatic Fire Sprinkler Systems Wet Pipe Systems Monthly Service Record Page 1 of 1 LB2A Automatic Fire Sprinkler Systems Wet Pipe Systems Section 2 of. It is designed for Wet Pipe Systems as well as the wet pipe components that are applicable to Dry Pipe Systems, Deluge and Water Spray Systems and Pre-action Systems. LB2A Automatic Fire Sprinkler Systems Wet Pipe Systems Automatic Fire Sprinkler Systems Dry Pipe, Deluge / Water Spray and Pre-Action Systems LB2B Automatic Fire Sprinkler Systems Dry Pipe, Deluge / Water Spray and Pre-Action Systems Monthly Service Record Page 1 of 1 LB2B LB2B Automatic Fire Sprinkler Systems Fire Pump Sets Section 2 of. It is designed for Dry Pipe Systems, Deluge and Water Spray Systems and Pre-action Systems. This logbook is to be used in conjunction with logbook LB2A Automatic Fire Sprinkler Systems Wet Pipe Systems. LB3A Fire Pumpsets Electric Motor Six Monthly / Yearly Service Record Page 1 of 1 LB3A Fire Pumpsets Electric Motor Section 3 of. It is designed for Electric Motor Driven Pumpsets, Hose Reel Pumpsets and Pressure Maintenance/Jacking Pumpsets. LB3A Fire Pumpsets Electric Motor LB3B Fire Pumpsets Compression Ignition (Diesel) Six Monthly / Yearly Service Record Page 1 of 1 LB3B Fire Pumpsets Compression Ignition (Diesel) LB3B Fire Pumpsets Compression Ignition (Diesel) Contains the records of service as stipulated in Section 3 of. It is designed for Compression Ignition (Diesel) Driven Pumpsets, Hose Reel Pumpsets and Pressure Maintenance / Jacking Pumpsets.

5 Annual Survey Note: The purpose of the annual survey is to identify component degradation and building changes that may impact on system or equipment performance. It is a visual inspection, typically conducted from floor level. It is designed to identify the potential for further investigation to assess any changes to the occupancy, environment or building that may affect the performance of the fire safety system or equipment. Where the outcome of the survey identifies the need for further investigation, it is recommended that a Fire Safety Audit in accordance with AS 4655 be undertaken by an appropriately qualified professional. An audit will support a responsible entity in satisfying themselves that any changes made to the fire safety system, building or occupancy are fully compliant with any applicable legislative requirements. Preliminary survey questions for the owner / occupier Yes No Not Known Has the occupant been in the building for the previous 12 months? Have there been any additions or alterations (minor or major) made to the building in the last 12 months? Have there been any changes made to the occupancy of the building? Have any of the fire safety systems or equipment in the building been altered or undergone major repairs in the last 12 months? Specific survey items from relevant table Item Actions required by Table Pass Fail N/A 3.11 Check installation 3.12 Check design Outcome of Annual Survey Yes No Further Action / Investigation Recommended Activity / System Failures Item Defect Description / Corrective Action Required or Repairs Completed Defect Identified on notes page Work Order System Interface Test s Note: Refer to system interface diagram and test plan Pass Fail N/A Pass Fail N/A Door release Stair pressurisation Roof vents Smoke control / exhaust Warning system / intercom HAC controls Plant shutdown Special Hazards Fuel isolation Notification and alert systems Elevator override Other Systems (Detail below) Pass Fail N/A / Distribution of service record copies: owner/occupier/agent = original service provider = duplicate retained in this book = triplicate LB4 1.0 April 2014 Time For details on the required test regime see seperating tab or refer to Appendix G of AS Place a tick ü in the numbered boxes for detectors & sampling points complying with response limits listed below. Place a cross û in the numbered boxes for detectors & sampling points not complying with response limits listed below. Date Alarm Zone Detectors & Sampling Points Tested Response Limits Detector Lower Limit Upper Limit Reference Distribution of service record copies: owner/occupier/agent = original service provider = duplicate retained in this book = triplicate 1.0 April 2014 Work Order Item Actions required by Table Pass Fail N/A Item Actions required by Table Pass Fail N/A Rectangular Panel Tanks 3.35 isually inspect internal stay support system All Tanks Pressure Tanks 3.1 Complete monthly and six monthly service 3.36a Inspect tank condition 3.2 Check for water leakage 3.3 Check for loose components 3.36b erify low water level alarm Alarm level (m) 3.4 Check for external damage Tanks with Liners Above the Waterline 3.5 Check foundation 3.21 Check liner fixing system 3.6 Check for corrosion 3.22 Check liner for discolouration 3.7, 3.8, 3.9 Check access hatch, ladder & roof 3.23 Check liner for shrinkage 3.24 Check liner for brittleness 3.10 Check vermin proofing 3.25 Check liner for cuts and tears 3.11 Check for foreign objects 3.26 Check liner for surface deterioration 3.12 Check for algae Tanks with Liners Below the Waterline 3.13 Check vents 3.27 Check liner flexibility 3.14 Check tank access 3.28 Check liner for discolouration 3.15 Check condition of signage Check condition of gaskets and seals 3.30 Check liner for signs of elongation or bulging 3.17 Check condition of vortex inhibitor 3.31 Check liner for leaks, cuts and tears 3.18 Service-level indicator components 3.32 Drain, clean and refill (see notes in AS1851) 3.19 Check compatibility of hard suction fittings 3.33 Check sludge depth 3.20 Drain, clean and refill tank 3.34 Check tank base (Only required after 1st year of install then every ten years) Activity / System Failures Item Defect Description / Corrective Action Required or Repairs Completed Defect Identified on notes page / Distribution of service record copies: owner/occupier/agent = original service provider = duplicate retained in this book = triplicate LB5 1.0 April 2014 Work Order Item MONTHLY Actions required by Table Pass Fail N/A Item YEARLY Actions required by Table Pass Fail N/A 2.13 Confirm fault condition indication 2.14 Test visual indicators and alphanumeric displays 1.1 Inspect baseline data 2.15 Measure and verify battery capacity (record in table below) 1.2 Inspect zone block plan 2.16 Test ancillary controls 1.3a & b Check condition of warning system panel 2.17 Test audibility 1.3c Check replacement element and tool for MCP s (w/a) 2.18 Test alarm signal override 1.4 Inspect battery enclosure 2.19 Test and verify system interfaces 1.5 Test warning signal operation Item YEARLY Actions required by Table Pass Fail N/A Date last replaced 2.20 erify battery condition Test load current (A) Final test voltage () 2.1 Complete monthly service 2.21 Check building layout changes 2.2 & Check and test emergency call points 2.22 Check occupancy changes 2.4 & 2.5 Inspect and test visual warning devices (WDs) 2.6 & 2.7 Inspect and test other warning devices Battery Capacity Test s 2.8 Inspect as installed drawings Quiescent Current (I Q) A Calculated 20h rate Capacity Ah 2.9 Test warning system initiation Alarm Mode Current (I Age factor A) A (calculated capacity X 1.25) Ah 2.10 Test circuit fault condition throughout system Required Quiescent 2.11 Test aural indicators Standby Time h Required Capacity Ah Required Alarm Mode 2.12 Test panel switches and keypads Standby Time h Fitted Capacity Ah Associated / Connected Equipment Service Completed Yes No N/A If No or N/A, indicate reason below Monthly fire detection system Yearly fire detection system Activity / System Failures Item Defect Description / Corrective Action Required or Repairs Completed Defect Identified on notes page / Distribution of service record copies: owner/occupier/agent = original service provider = duplicate retained in this book = triplicate LB6B 1.0 April 2014 S LB4 Fire Hydrant Systems Yearly Service Record Page 2 of 2 LB4 Fire Hydrant Systems LB4 Fire Hydrant Systems Section 4 of. It is designed for Fire Hydrant Installations, Fire Mains and Fire Hydrant Booster Assemblies. LB5 Water Storage Tanks for Fire Protection Systems Yearly Service Record Page 1 of 1 LB5 Water Storage for Fire Protection Systems Section 5 of. It is designed for Water Storage Tanks for Fire Protection Systems. LB5 Water Storage Tanks for Fire Protection Systems Fire Detection and Alarm Systems Detector Test Record Page 1 of 1 Fire Detection and Alarm Systems Fire Detection & Alarm Systems General Requirements (A4 & A5 size) Section 6 of. It is designed for Fire Detection and Alarm Systems including those functions that control the operation of Special Hazard Systems and Smoke Hazard Management Systems. (A4 size, contains notes pages) LB6B Emergency Warning Systems (EWS) and Emergency Intercom Systems (EIS) EWS Monthly / Yearly Service Record Page 1 of 1 LB6B Fire Detection & Alarm Systems Emergency Warning Systems & Emergency Intercom Systems Contains the records of service as stipulated in Section 6 of. It is designed for Emergency Warning Systems and Emergency Intercom Systems. LB6B Emergency Warning Systems (EWS) and Emergency Intercom Systems (EIS)

6 Work Order Item Required Actions Pass Fail N/A Item Required Actions Pass Fail N/A FIRE & SMOKE BARRIERS WALLS Table FIRE-PROTECTED STRUCTURAL MEMBERS Table Compare walls with approved design 2.1 Compare structural members with approved design 1.2a & b Compare wall penetrations with approved design 2.2 Check condition of structural members including mechanical damage 1.2c Identify any unprotected or unsuitable wall penetrations Inspect walls to ensure compartmentation is complete and deterioration, damage or integrity as applicable 1.3 for any loss of fire resistance FIRE-RATED GLAZING Table FIRE & SMOKE BARRIERS FLOORS Table Check for modifications to glazing that differ from the approved design 2.1 Compare floors with approved design 6.2 Check condition of glass 2.2a & b Compare floor penetrations with approved design 6.3 Check frame for damage and perimeter gaps are protected 2.2c Identify any unprotected or unsuitable floor penetrations 6.4 Check glazing seals are present and have not deteriorated Inspect floors for loss of fire resistance FIRE-PROTECTED AIR DUCTS Table FIRE & SMOKE BARRIERS CEILINGS Table Check for modifications to air ducts 3.1 Compare ceilings with approved design 7.2 Check drawings for details of fire protection system 3.2a & b Compare ceiling penetrations with approved design c Identify any unprotected or unsuitable ceiling penetrations deterioration or damage FIRE & SMOKE BARRIERS FIRE & SMOKE RATED ACCESS PANELS & HATCHES Table Report identified deficiencies and amend schedule 4.1 Compare access panels with approved design 4.2 Inspect access panel and perimeter seal for damage YEARLY SERICE SCHEDULE EQUIPMENT REGISTER 4.3 Inspect and verify condition of access panel frame PENETRATIONS Total number of penetrations 4.4 Inspect screw-fixings (where applicable) Tally of s Checked Passed Failed 4.5 Inspect hinges and latches (where applicable) 4.6 Inspect for any interference with panel function RESULTS OF ROUTINE SERICE ACTIITIES Refer to equipment register for details of penetration location, protection type used and other relevant details ID ID ID ID ID Distribution of service record copies: owner/occupier/agent = original service provider = duplicate retained in this book = triplicate 1.0 April 2014 RESULTS OF INSPECTION & MAINTENANCE PROCEDURES Refer to as-installed plans or schedule for identification and type of luminaire or exit sign ID ID ID ID ID ID ID / Item Description / Corrective Action Required or Repairs Completed on notes page Distribution of service record copies: owner/occupier/agent = original service provider = duplicate retained in this book = triplicate LBE2 1.0 April 2014 Time Work Order Item Actions required by Table Pass Fail N/A Item Actions required by Table Pass Fail N/A 3.18 Inspect areas adjacent to protected areas 3.19 Test operation of ventilation dampers 3.1 Complete monthly and six monthly service 3.21 Test post-discharge ventilation 3.2 Complete yearly electrical detection and control systems service 3.22 Confirm operation of directional valves 3.3 Identify test date of gas storage containers HAC 3.4 Service mechanical actuator & mechanical release system Test and verify interfaced EWS 3.5 Service detection system (mechanical) 3.23 system initiation Power shut-off 3.6 Replace detection devices (mechanical) as necessary Fuel shut-off 3.7 Check location of detection devices (mechanical) Aerosol Systems Additional Activities 3.8 Replace pyrotechnic actuator as necessary 3.24 Replace aerosol generators as necessary 3.9 Clean nozzles Water Mist Systems Additional Activities 3.10 Clean dampers 3.25 Conduct full flow test 3.11 Check for any unintentional discharge condition 3.26 Check water additive concentration 3.12 erify hazard fuel type 3.27 Service line strainers and filter 3.13 erify enclosure volume for total flooding systems 3.28 Inspect internal condition of container 3.14 erify design concentration or application density The following Activities are required to be performed every ten years ONLY 3.15 erify dimensions of protected objects local application systems 4.2 Test flow from nozzles Complete enclosure Equivalent leakage area m Pressure test gas storage container 3.16 integrity test (total flooding systems) Retention time (gaseous systems only) min 4.4 Inspect internally gas storage container 3.17 Test pressure-relief vent operation (where fitted) Activity / System Failures Item Defect Description / Corrective Action Required or Repairs Completed Defect Identified on notes page / Distribution of service record copies: owner/occupier/agent = original service provider = duplicate retained in this book = triplicate LB7 1.0 April 2014 Work Order Item Required procedures Pass Fail N/A Item Required procedures Pass Fail N/A All previously identified corrective action attended to Inverters (Clause.4) Continued & Check that no power interruption has occurred in the 16 Check calibration of voltmeters preceding 16 hour period Distribution and Control Equipment (Clause.5) Batteries (Clause.2) 17 Inspect all components for signs that may result in malfunction 1 Check battery electrolyte levels and inspect for leakage 18 Check connections are tight Inspect battery connections for corrosion and tighten 2 where required 19 Remove any dust or dirt from within enclosures 3 Apply appropriate preservative to exposed metal surfaces 20 Isolate coil circuits from a.c. supply and observe correct operation of lighting For lead acid batteries determine the electrolyte density 4 for each cell (record in table below) Emergency Luminaires and Exit Signs (Clause.6) Measure overall battery voltage and individual cell voltage 5 (record in table below) 21 Check operation of all emergency luminaires and exit signs (record results on lighting test record) Battery Charger Assembly (Clause.3) 22 Clean all light-emitting and reflecting surfaces 6 Inspect all components for signs that may result in malfunction 23 Indirect lighting systems check reflecting surfaces 7 Remove any dust or dirt from cubicle 24 Indirect lighting systems where relevant, check beam direction is appropriate erify battery voltage is Measured 8 consistent with system 25 Check system operates in correct relationship to normal lighting requirements Required System Check Manual Discharge Test (Clause.7.1) 9 Check connections are tight Conduct a manual discharge test for systems that 26 incorporate manual discharge test facilities. Run test for 10 Check calibration of voltmeters required in-service duration 11 Check battery earth-fault detection system On completion of discharge test 27 measure battery voltage and check it 12 Check battery low-voltage alarm is within acceptable limits Inverters (Clause.4) Check battery charger changes to float charge mode manual 28 boost-charge recharge 13 Inspect all components for signs that may result in malfunction For d.c. reticulated systems 29 measure max voltage at origin Check and verify d.c. input voltage during boost charging 14 and current is within tolerance limits of the inverter A System Check Automatic Discharge Test (Clause.7.2) 30 Conduct an automatic discharge test for systems that Check and verify a.c. output incorporate automatic discharge test facilities 15 voltage and current is within the output tolerances of the inverter A Battery Test s Overall Cell 1 Cell 2 Cell 3 Cell 4 Cell 5 Cell 6 Electrolyte Density (Lead Acid Batteries) State of Charge (Lead Acid Batteries) Float Charge (All Batteries) This record of service confirms that the Emergency Evacuation Lighting system has been inspected and maintained in accordance with AS and that the information on this service record is true and correct. This record BUILDINGS does not infer compliance with ONLY / Distribution of service record copies: owner/occupier/agent = original service provider = duplicate retained in this book = triplicate 1.0 April 2014 S LB7 Special Hazards Systems Yearly Service Record Page 1 of 1 LB7 Special Hazard Systems Section 7 of. It is designed for Special Hazard Systems including Aerosol Systems, Water Mist Systems. LB7 Special Hazard Systems Fire & Smoke Barriers & Construction Elements Summary Service Record Page 1 of 1 Passive Fire & Smoke Systems Fire & Smoke Barriers & Construction Elements Passive Fire Smoke Systems Fire & Smoke Barriers & Construction Elements (3 years) Contains the records of services as stipulated in Section 12 of. It is designed for Fire and Smoke Barriers, Service Penetrations, Control Joints, Access Panels and Hatches, Fire Protected Structural Members, Fire Rated Glazing and Fire Protected Air Ducts. Emergency Evacuation Lighting for Buildings Central Systems Emergency Escape Lighting & Exit Signs Central Systems (3 years) Contains the records of service as required by AS It is designed for Emergency Escape Lighting and Exit Signs Central Point Systems. AS/NZS Yearly Service Record Page 1 of 1 Emergency Evacuation Lighting for Buildings Central Systems LBE2 Emergency Evacuation Lighting for Buildings Single Point Systems Lighting Test Record Page 1 of 1 AS/NZS LBE2 Emergency Evacuation Lighting for Buildings Single Point Systems LBE2 Emergency Escape Lighting & Exit Signs Single Point Systems (3 years) Contains the records of service as required by AS It is designed for Emergency Escape Lighting and Exit Signs Single Point Systems.

7 WHEELED FIRE EXTINGUISHERS Continued Item Actions Required Yearly Service Table Check operating head or cap is undamaged and any strainer or vents are clear 1 Check extinguisher discharges correctly in accordance with the operating instructions Check alterations to the building that might affect coverage or impede Five Yearly Service Table Check extinguisher discharges correctly in accordance with the operating instructions Check internal condition of cylinder in accordance with the requirements of AS Pressure test wheeled extinguishers in accordance with AS at an approved test station Recharge the extinguisher with fresh extinguishing agent as required by the manufacturer 3 Renew seals and gaskets fitted to the actuating device, operating head or cap. Pressure test hose assembly to 1.5x the working pressure or 2MPa 3.13 whichever is the greatest (for all wheeled extinguishers other than CO2). For CO2, pressure test hose assembly to 10MPa 1 Water with additive ONLY 2 Only applies to water with additive (discharged yearly) and water with corrosion inhibitor or freezing point depressants (discharged 3 yearly). 3 Applies to foam (gas container with sealed foam liquid container) ONLY EXTINGUISHER TYPE STORED PRESSURE GAS CONTAINER Required Action Reference Guide Page 4 of 4 SR April 2014 Work Order FIRE DOORS Tables & EQUIPMENT REGISTER: Total number of Fire Doors: Fire Door Tally of s of Service Completed Checked Passed Failed Missing 3 Monthly 6 Monthly Hinged & pivoted fire-resistant doorsets Horizontal sliding fire-resistant doorsets Equipment Tally of s System Register Total Checked Passed Failed Missing SMOKE DOORS 6 MONTHLY Tables FIRE SHUTTERS YEARLY Table RESULTS OF ROUTINE SERICE ACTIITIES Refer to equipment register for details of equipment type, location and other relevant details ID ID ID For sites with more than 75 fire and smoke doors: Record additional items on Additional Equipment Test Record contained in Supplementary Forms Book Activity / System Failures Legend Refer to equipment register for details of equipment type, location and other relevant details ID Defect Description / Corrective Action Required or Repairs Completed I hereby certify that the above system / equipment has been routinely serviced in accordance with AS and that the information on this service record is true and correct. This record does not infer compliance with / Distribution of service record copies: owner/occupier/agent = original service provider = duplicate SR12B 1.0 April 2014 Work Order Item Required Actions Pass Fail N/A Item Required Actions Pass Fail N/A FIRE & SMOKE BARRIERS WALLS Table FIRE-PROTECTED STRUCTURAL MEMBERS Table Compare walls with approved design 2.1 Compare structural members with approved design 1.2a & b Compare wall penetrations with approved design 2.2 Check condition of structural members including mechanical damage 1.2c Identify any unprotected or unsuitable wall penetrations Inspect walls to ensure compartmentation is complete and deterioration, damage or integrity as applicable 1.3 for any loss of fire resistance FIRE-RATED GLAZING Table FIRE & SMOKE BARRIERS FLOORS Table Check for modifications to glazing that differ from the approved design 2.1 Compare floors with approved design 6.2 Check condition of glass 2.2a & b Compare floor penetrations with approved design 6.3 Check frame for damage and perimeter gaps are protected 2.2c Identify any unprotected or unsuitable floor penetrations 6.4 Check glazing seals are present and have not deteriorated Inspect floors for loss of fire resistance FIRE-PROTECTED AIR DUCTS Table FIRE & SMOKE BARRIERS CEILINGS Table Check for modifications to air ducts 3.1 Compare ceilings with approved design 7.2 Check drawings for details of fire protection system 3.2a & b Compare ceiling penetrations with approved design c Identify any unprotected or unsuitable ceiling penetrations deterioration or damage FIRE & SMOKE BARRIERS FIRE & SMOKE RATED ACCESS PANELS & HATCHES Table Report identified deficiencies and amend schedule 4.1 Compare access panels with approved design 4.2 Inspect access panel and perimeter seal for damage YEARLY SERICE SCHEDULE EQUIPMENT REGISTER 4.3 Inspect and verify condition of access panel frame PENETRATIONS Total number of penetrations 4.4 Inspect screw-fixings (where applicable) Tally of s Checked Passed Failed 4.5 Inspect hinges and latches (where applicable) 4.6 Inspect for any interference with panel function RESULTS OF ROUTINE SERICE ACTIITIES Refer to equipment register for details of penetration location, protection type used and other relevant details ID ID ID ID ID Distribution of service record copies: owner/occupier/agent = original service provider = duplicate SR12A 1.0 April 2014 SRFORMS1 Supplementary Forms Book Additional Equipment Test Record Work Order Associated Sheet ID RESULTS OF ROUTINE SERICE ACTIITIES Refer to equipment register for details of equipment type, location and other relevant details ID Service ID Service ID Service ID Service ID Service ID Service ID Service ID Service ID Service Distribution of service record copies: owner/occupier/agent = original service provider = duplicate SRFORMS1 1.0 April 2014 SUMMARY RECORDS SR8-11 Fire Extinguishers, Blankets, Hose Reels & Lay Flat Hose Required Action Reference Guide Page 4 of 4 SUMMARY RECORD Fire Extinguishers, Blankets, Hose Reels & Lay Flat Hose 2.1 Complete six-monthly service 2.4 Check actuating device is undamaged and moves freely 2.5 Check internal components provide clear passage and are securely attached Check cylinder interior is clean 2.8 Recharge the extinguisher with fresh extinguishing agent Check condition of operating head or cap seal Test for leaks from any joints and seals Check fire hazard has not changed 2.12 Check suitability for hazard is appropriate access to extinguisher, or movement of wheeled extinguisher 3.1 Complete six-monthly and yearly service 3.3 Check actuating device is undamaged and moves freely 3.4 Check internal components provide clear passage and are securely attached SR Check condition of operating head or cap seal 3.12 Test for leaks from any joints and seals Powder Water Carbon Dioxide Foam Wet Chemical aporising Liquid Powder Water Foam SR8-11 Fire Extinguishers, Blankets, Hose Reels & Lay Flat Hose Contains the records of services as stipulated in Sections 8,9,10 and 11 of. It is designed for Portable and Wheeled Fire Extinguishers, Fire Blankets, Fire Hose Reels and Delivery Lay Flat Fire Hose. SR12A Fire & Smoke Barriers & Construction Elements Section 12 of. It is designed for Fire and Smoke Barriers, Service Penetrations, Control Joints, Access Panels and Hatches, Fire Protected Structural Members, Fire Rated Glazing and Fire Protected Air Ducts. SUMMARY RECORD SR12A Fire & Smoke Barriers & Construction Elements Summary Service Record Page 1 of 2 SR12A Passive Fire & Smoke Systems Fire & Smoke Barriers & Construction Elements SR12B Summary Service Record Page 1 of 1 SUMMARY RECORD SR12B Passive Fire & Smoke Systems SR12B Contains the records of service as stipulated in Section 12 of. It is designed for Fire Resistant Doorsets, Smoke Doors and Fire Shutters ADDITIONAL BOOKS SRFORMS1 Supplementary Forms Book Contains additional Notes/Comments records and additional Equipment Test records that have been designed to supplement the standard forms contained in logbooks and summary records books. SUPPLEMENTARY FORMS SRFORMS1 Supplementary Forms Book Supplementary Notes / Comments Record Additional Equipment Test Record

8 Fire Protection Association Australia Building 2, Joseph Street Blackburn North IC Australia 3130 PO Box 1049 Box Hill IC Australia 3128 P E shop@fpaa.com.au F W For more information visit

Developments in Australian Standard AS (Emergency Lighting)

Developments in Australian Standard AS (Emergency Lighting) Developments in Australian Standard AS2293.2 (Emergency Lighting) Russell Porteous Chief Executive Officer, Firewize Australian Standards Committee LG-007 Disclaimer Firewize policy is one of continuous

More information

Scope. Warning sounders except specific requirements. Intercom Systems for Emergency Purposes. Sound Systems for Emergency Purposes

Scope. Warning sounders except specific requirements. Intercom Systems for Emergency Purposes. Sound Systems for Emergency Purposes Scope Section 6 covers all Control and Indicating Equipment including Local Alarm systems. Section 6 also covers all detectors and input/output devices, including Occupant Warning sounders except specific

More information

Fire Protection, Inspection and Testing Qualifications Forums. Jeremy Rose (Artibus Innovation) Chris Wyborn (FPA Australia)

Fire Protection, Inspection and Testing Qualifications Forums. Jeremy Rose (Artibus Innovation) Chris Wyborn (FPA Australia) Fire Protection, Inspection and Testing Qualifications Forums Presenters: Jeremy Rose (Artibus Innovation) Chris Wyborn (FPA Australia) Welcome Agenda New arrangements for training package development

More information

Engineering Standard MCST FIRE PROTECTION SYSTEMS AND EQUIPMENT MAINTENANCE IN THE MURL

Engineering Standard MCST FIRE PROTECTION SYSTEMS AND EQUIPMENT MAINTENANCE IN THE MURL Engineering Standard - Maintenance Structures & Facilities MCST 030200-01 FIRE PROTECTION SYSTEMS AND EQUIPMENT Engineering Standard Owner: Standards Development Manager Approved By: Ahmed Dwidar Standards

More information

Index. Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8. Fire Risk Assessments 9

Index. Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8. Fire Risk Assessments 9 Index Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8 Fire Risk Assessments 9 Fire Alarm Systems 10-20 Locations 10 Servicing 11 12 Activations 13 14 Weekly Checks

More information

Maintenance of Fire Systems

Maintenance of Fire Systems Maintenance of Fire Systems Duty Holder Facilities Manager Responsible Person By John Briggs All Fire Facilities, equipment, systems and devices are required by law to be subject to a suitable system of

More information

Scope of Section 2. AS vs. Application Issues. Schedules & Log- Contents. Books

Scope of Section 2. AS vs. Application Issues. Schedules & Log- Contents. Books Contents Scope of Section 2 Application Issues AS 1851-1997 vs 2005 Schedules & Log- Books Scope of AS1851 Section 2 Review and rewrite of all sprinkler maintenance activities AS 1851.3 1997 becomes General

More information

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES SHIPPING NOTICE Maritime Authority of the Cayman Islands Head Office 3 rd Floor, Government Administration Building, 133 Elgin Avenue PO Box 2256, Grand Cayman, KY1-1107, Cayman Islands Tel: +1 345 949

More information

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location: Global Property SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Plant: Date of Inspection Location: Inspected By: Reviewed By CONTROL VALVES (If Valves are Not Locked Open or Electronically Supervised

More information

2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7

2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7 WET SPRINKLER Monthly Wet Sprinkler 2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7 VISUALS [per NFPA 25-1998 ed] 1. Gauge (Ck for Condition, Normal Pressure) [per 2-2.4.1] 2. Valves

More information

Revised March 2015 Fire Alarm Systems Verification. Schedule I(A) Services. *Manditory Site visit required*

Revised March 2015 Fire Alarm Systems Verification. Schedule I(A) Services. *Manditory Site visit required* 1.0 Description of Services Required: Revised March 2015 Fire Alarm Systems Verification Schedule I(A) Services *Manditory Site visit required* Perform the annual fire alarm system and sprinkler system

More information

Loss Prevention Standards

Loss Prevention Standards Introduction Fire compartmentation is an essential part of an effective fire safety design of a building. The primary objective of fire compartmentation or passive fire protection is to prevent a building

More information

BUILDING CODE ACCESS CONSULTING ESSENTIAL SERVICES

BUILDING CODE ACCESS CONSULTING ESSENTIAL SERVICES Essential Safety Measures - Fire & Smoke Control of Mechanical Services Antony Rickards Building Compliance BUILDING CODE ACCESS CONSULTING ESSENTIAL SERVICES Essential Safety Measures What we will cover.

More information

BERMAD Fire Protection

BERMAD Fire Protection Model: 400E-3M Bermad Electro-Pneumatically Controlled Deluge Valve with Easy Lock Manual Reset Installation Operation Maintenance Safety First BERMAD believes that the safety of personnel working with

More information

MAINTENANCE OF ESSENTIAL SAFETY MEASURES EXPLAINED (Building Regulations 2006)

MAINTENANCE OF ESSENTIAL SAFETY MEASURES EXPLAINED (Building Regulations 2006) MAINTENANCE OF ESSENTIAL SAFETY MEASURES EXPLAINED (Building Regulations 2006) 1. INTRODUCTION 1.1 Essential Safety Measures Defined Essential Safety Measures (previously called essential services) are

More information

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT Factory Plot # 33-36 Sector # 07, Chittagong Chittagong Chittagong 08 Jun 2014 The Alliance for Worker Safety Page 1/18 08 Jun 2014 Introduction to the Report

More information

Global Property. QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

Global Property. QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location: Global Property QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Plant: Date of Inspection Location: Inspected By: Reviewed By CONTROL VALVES (If Valves are Not Locked Open or Electronically Supervised

More information

Emergency Evacuation Lighting Inspection & Maintenance

Emergency Evacuation Lighting Inspection & Maintenance Emergency Evacuation Lighting Inspection & Maintenance Got Questions? We re here to help 1300 038 847 Why Test Emergency Lighting Online Enquiry Australian Standard AS/NZS 2293.2 1995 relates to inspection

More information

Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System

Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System Building/Business Name: Address of Property: Inspector Name: Joe Price THE CORNERSTONE 1425 NE 7TH AVENUE PORTLAND OR Date

More information

AS 1851:2012 The Use and Adoption of the New Standard The impacts and challenges for the fire protection and property management industries.

AS 1851:2012 The Use and Adoption of the New Standard The impacts and challenges for the fire protection and property management industries. AS 1851:2012 The Use and Adoption of the New Standard The impacts and challenges for the fire protection and property management industries. Development of the new Standard Chris Wyborn Senior Technical

More information

Checklist For Life Safety

Checklist For Life Safety INSPECTION CHECKLIST Date of Inspection: Location/Address: Weather Condition: Inspector: AFTER COMPLETING YOUR INSPECTION, TRANSFER YOUR CONCERNS/OBSERVATIONS TO THIS AREA Facility: Name: Staff Contact:

More information

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE PUMP REVIEW Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved; AC-Approved w/comments;

More information

Queensland Building Plan (Licensing Reform) FPA Australia Submission

Queensland Building Plan (Licensing Reform) FPA Australia Submission Queensland Building Plan (Licensing Reform) FPA Australia Submission Table of contents 1.0 Executive Summary... 2 2.0 About FPA Australia... 3 3.0 Introduction... 6 4.0 Background... 6 5.0 Fire Occupational

More information

ISLE OF WIGHT FIRE & RESCUE SERVICE

ISLE OF WIGHT FIRE & RESCUE SERVICE ISLE OF WIGHT FIRE & RESCUE SERVICE Record of Fire Safety Equipment Testing Fire Drills & Training CONTENTS 1. MEANS OF ESCAPE 2. FIRE WARNING AND AUTOMATIC FIRE DETECTION 3. FIRE EXTINGUISHERS AND HOSEREELS

More information

SCHEDULE. Essential Safety Measures taken from Schedule 9 of the Building Regulations PART 1 BUILDING FIRE INTEGRITY

SCHEDULE. Essential Safety Measures taken from Schedule 9 of the Building Regulations PART 1 BUILDING FIRE INTEGRITY SCHEDULE Essential s taken from Schedule 9 of the Building Regulations 2006 43 PART 1 BUILDING FIRE INTEGRITY 1 Building elements required to satisfy prescribed fire-resistance levels 2 Materials and assemblies

More information

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10 highline WINDOW CONTROLS INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM SVCS-1 * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10 CERTIFICATE OF COMPLIANCE SVCS-1 We the undersigned

More information

Baseline Data Required for AS

Baseline Data Required for AS Baseline Data Required for AS 1851-2012 Name: Brett Dundules Position: Technical Officer Organisation Fire Protection Association Australia Introduction Brief History of AS 1851-2012 Introduction of Baseline

More information

Statutory Compliance Checklist

Statutory Compliance Checklist Date of Issue: April 2017 Statutory Compliance Checklist This document is for clergy and churchwardens to help them in the maintenance of their Churches. Refer to supplementary notes for further guidance.

More information

F I R E S A F E T Y R E G I S T E R

F I R E S A F E T Y R E G I S T E R F I R E S A F E T Y R E G I S T E R (Short Version) Cork County Fire Department www.corkcoco.ie April 2015 Introduction 1.1 Section 18(2) of the Fire Services Acts, 1981 and 2003 generally applies to all

More information

CERTIFICATION SAFETY & BEYOND

CERTIFICATION SAFETY & BEYOND CERTIFICATION SAFETY & BEYOND Ferhun Emeksiz & R.M ( Max) Bradbury Client Manager & Fire Products Program Manager Global-Mark Pty Ltd Content Product Certification Understanding the framework Fundamental

More information

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION INITIAL FIRE SAFETY ASSESSMENT - EXPANSION Factory Mogorkhal, Chowrasta, National University, Gazipur Gazipur Dhaka 09 May 2016 The Alliance for Worker Safety Page 1/13 09 May 2016 Introduction to the

More information

Service Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT

Service Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT 58 Fire protection equipment requires care and maintenance at scheduled intervals to assure it will operate properly and safely when needed. Only personnel who are trained and qualified to maintain the

More information

Alarm Signalling Equipment: Connection Requirements (Victoria) TAN 06. Technical Advisory Note. Version 1 October 2018

Alarm Signalling Equipment: Connection Requirements (Victoria) TAN 06. Technical Advisory Note. Version 1 October 2018 TAN 06 Alarm Signalling Equipment: Connection Requirements (Victoria) Version 1 October 2018 1 1 Purpose statement The purpose of this is to provide advice concerning the legislative requirements for the

More information

Fire Sprinkler Plan Submittal Form

Fire Sprinkler Plan Submittal Form Contents Fire Sprinkler Plan Submittal Form... 2 Standpipe Plan Review Submittals... 4 Fire Pump Plan Submittal Requirements... 6 Fire Alarm Plan Submittal Form... 8 Kitchen Hood Wet Chemical Submittal...10

More information

ClassNK Technical Information No. TEC-0970 For any questions about the above, please contact: NIPPON KAIJI KYOKAI (ClassNK) Survey Department, Adminis

ClassNK Technical Information No. TEC-0970 For any questions about the above, please contact: NIPPON KAIJI KYOKAI (ClassNK) Survey Department, Adminis Subject Maintenance, inspection and test of Fire-Protection Systems and Appliances on board the Panama-registered ships To whom it may concern Technical Information No. TEC-0970 Date 31 October 2013 The

More information

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER The 2016 Denver Building and Fire Code includes the following codes except as amendment herein. 2015 IBC (Building) 2015 IFC (Fire)

More information

Winnipeg Fire Department Fire Prevention Branch

Winnipeg Fire Department Fire Prevention Branch Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of

More information

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT INITIAL FIRE SAFETY ASSESSMENT Assessor: 28 S.S. Tower, Vogra, Joydebpur, Gazipur Joydebpur, Gazipur Dhaka Uttaron The Alliance for Worker Safety Page 1/17 12 Apr 2015 Introduction to the Report The following

More information

THE FIRE SAFETY GUIDE FOR BUSINESS OWNERS

THE FIRE SAFETY GUIDE FOR BUSINESS OWNERS THE FIRE SAFETY GUIDE FOR BUSINESS OWNERS 0800 2211 8034 Table of Contents Part 1: Introduction Part 2: Who is Responsible? Part 3: What is Required? Fire Risk Assessments Appointment of Competent Persons

More information

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT Factory Name: 4 YOU CLOTHING LTD 367/1 Senpara Parbata, Mirpur-10, Dhaka Dhaka Dhaka Bangladesh 27 May 2014 The Alliance for Bangladesh Worker Safety Page 1/20

More information

Functional Performance Test

Functional Performance Test Fire Alarm Control Panel & Fire Alarm Annunciator Panel Notify all building occupants that testing will be conducted. Fire alarm contractor shall have personnel with 2-way radios at the fire alarm control

More information

Allfire Site No. a division of Allsaved Ltd. Fire Safety Log Book. Premises Address: Responsible Person:

Allfire Site No. a division of Allsaved Ltd. Fire Safety Log Book. Premises Address: Responsible Person: Site No. a division of Allsaved Ltd. Fire Safety Log Book Premises Address: Responsible Person: Introduction An Introduction to Your Fire Safety Log Book The Regulatory Reform (Fire Safety) Order 2005

More information

Automatic Sprinkler Systems Care and Maintenance

Automatic Sprinkler Systems Care and Maintenance 0-0.0 January 2012 Country of Origin: United Kingdom Automatic Sprinkler Systems Care and Maintenance Introduction...1 Weekly Inspection and Tests...2 Monthly Inspection and Tests...3 Service and Maintenance

More information

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT BUILDING ASSESSMENT REPORT FIRE FOR 69 PRESIDENT SEPTEMBER 2014 Report for Department of Infrastructure Development Fire Services Preliminary Report: 69

More information

Guidance on Statutory Inspections Scheduling Tool

Guidance on Statutory Inspections Scheduling Tool Guidance on Statutory Inspections Scheduling Tool This Guideline has been produced solely for use by State Authorities that come within the remit of the State Claims Agency, as established by the National

More information

PREMISES FIRE SAFETY LOGBOOK

PREMISES FIRE SAFETY LOGBOOK 0844 740 3473 PREMISES FIRE SAFETY LOGBOOK PREMISES ADDRESS: LOG BOOK TO BE KEPT IN THIS LOCATION: AN INTRODUCTION TO YOUR LOG BOOK. The Regulatory Reform (Fire Safety) Order 2005 (FSO) requires that the

More information

Government of Bermuda Bermuda Shipping and Maritime Authority BERMUDA SHIPPING NOTICE

Government of Bermuda Bermuda Shipping and Maritime Authority BERMUDA SHIPPING NOTICE Government of Bermuda Bermuda Shipping and Maritime Authority 2017 021 BERMUDA SHIPPING NOTICE Maintenance and Inspection of Fire Protection Systems, Appliances and Certain Emergency Equipment Ref: SOLAS

More information

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be EMLC Academy Trust Fire Safety Policy 2017/19 Every child deserves to be the best they can be 1 Scope: EMLC Academy Trust & Academies within the Trust Version: 2 Filename: EMLC Academy Trust Fire Safety

More information

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment February 2017 Alberta Fire Code safety equipment maintenance requirements: The Black Diamond Fire Department has

More information

FIRE SAFETY LOGBOOK PREMISES ADDRESS: LOG BOOK TO BE KEPT IN THIS LOCATION: DSFRS Log book Version 1.0 (October 2007)

FIRE SAFETY LOGBOOK PREMISES ADDRESS: LOG BOOK TO BE KEPT IN THIS LOCATION: DSFRS Log book Version 1.0 (October 2007) FIRE SAFETY LOGBOOK PREMISES ADDRESS: LOG BOOK TO BE KEPT IN THIS LOCATION: AN INTRODUCTION TO YOUR LOG BOOK. This Fire Safety Log book has been prepared to assist the responsible person in coordinating

More information

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT INITIAL FIRE SAFETY ASSESSMENT Dhanpur, Chapapur, Kotwali, Comilla COMILLA Chittagong The Alliance for Worker Safety Page 1/16 Introduction to the Report The following report contains a site profile and

More information

AS 2419 OVERVIEW OF PROPOSED CHANGES. Gary Nenadovich Director G N Consulting

AS 2419 OVERVIEW OF PROPOSED CHANGES. Gary Nenadovich Director G N Consulting AS 2419 OVERVIEW OF PROPOSED CHANGES Gary Nenadovich Director G N Consulting Disclaimer FPA Australia's policy is one of continuous improvement, details of products, procedures or methods described within

More information

LICENCE. for. Click on the red box above to activate the Licence Agreement scroll bar.

LICENCE. for. Click on the red box above to activate the Licence Agreement scroll bar. LICENCE for Licensee: Date: Click on the red box above to activate the Licence Agreement scroll bar. See publications covering the same Subject Area Subscribe to our Free Newsletters about Australian Standards

More information

Inspection Records Schedule- Fire Extinguisher

Inspection Records Schedule- Fire Extinguisher CPP20511 Certificate II in Fire Protection Inspection and Testing WORKPLACE PROJECT ASSESSMENT PHASE 3: Task 1 Inspect & Test Fire Extinguishers Conduct a 6 monthly inspection on at least 4 portable fire

More information

Chapter 4: Fire Protection Systems

Chapter 4: Fire Protection Systems Chapter 4: Fire Protection Systems Automatic Extinguishing Systems (Fire Sprinklers) One of the most important aspects of a storage warehouse inspection is ensuring that the automatic extinguishing system

More information

System Test Report CLEAN AGENT

System Test Report CLEAN AGENT City of Black Hawk Fire Department 196 Clear Creek Street PO Box 68 Black Hawk, CO 80422-068 Office 303-582-0426 Fax 303-582-2229 www.cityofblackhawk.org System Test Report CLEAN AGENT Occupancy Information

More information

OWNER'S OPERATION AND MAINTENANCE MANUAL

OWNER'S OPERATION AND MAINTENANCE MANUAL OWNER'S OPERATION AND MAINTENANCE MANUAL P/N 15064 Amerex Industrial Dry Chemical Fire Suppression System MODELS IS18ABC (18 lb. ABC) / IS35ABC (35 lb. ABC) / IS45ABC (45 lb. ABC) / Manufactured by: AMEREX

More information

Fire Protection Accreditation Scheme (FPAS)

Fire Protection Accreditation Scheme (FPAS) Fire Protection Scheme (FPAS) A voluntary accreditation scheme for the fire protection industry covering inspect and test activities Information Guide December 2013 Fire Protection Association Australia

More information

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT INITIAL FIRE SAFETY ASSESSMENT Factory Assessor: Plot no. A102, BSCIC Industrial Estate, Tongi, Gazipur Tongi, Gazipur Emkay Enterprises 06 Jul 2014 The Alliance for Bangladesh Worker Safety Page 1/22

More information

Sheetz Inc. Fire Protection Service Guidelines

Sheetz Inc. Fire Protection Service Guidelines Sheetz Inc. Fire Protection Service Guidelines Overview The following are guidelines for Sheetz Fire Protection Services for the 2016/2018 contract year. Each key area is listed below with the appropriate

More information

INITIAL FIRE ASSESSMENT REPORT (FAR)

INITIAL FIRE ASSESSMENT REPORT (FAR) INITIAL FIRE ASSESSMENT REPORT (FAR) Factory SQ Station, Plot # 221-223, Jamirdia, Valuka, Mymensingh Mymensingh 17 Jun 2014 The Alliance for Bangladesh Worker Safety Page 1/17 Factory 17 Jun 2014 Introduction

More information

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater APPROVED BY: JBJ Precept EN Fire Detection/Alarm Panel & Precept EN Repeater Logbook PAGE 1 of 19 List of Contents 1. FIRE ALARM SYSTEM MAINTENANCE... 3 2. USER RESPONSIBILITIES... 3 2.1. RESPONSIBLE PERSON...

More information

Fire Safety Plan (Single-Stage Fire Alarm System) (Small Establishment):

Fire Safety Plan (Single-Stage Fire Alarm System) (Small Establishment): Fire Safety Plan (Single-Stage Fire Alarm System) (Small Establishment): Fire Safety Plan Single-Stage Fire Alarm System for: (Business Name) (Business Address) Submission Date - Submitted by - Signature

More information

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

S12 Fire Safety Risk Assessment H&SFS01-1 / 9 S12 Fire Safety Risk Assessment H&SFS01 Risk ratings The following risk ratings are based on two factors: The overall fire risk rating for the site The risk rating for the individual recommendations /control

More information

TOTALPAC2 Integrated Fire Protection System

TOTALPAC2 Integrated Fire Protection System TOTALPAC2 Integrated Fire Protection System Page 1 of 8 General 1. Applicable Standards The TOTALPAC2 Surefire complies with the following standards: - NFPA-13 Sprinkler Systems; - NFPA-15 Water Spray

More information

Attachment 1. to ClassNK Technical Information No. TEC-1077 Isle of Man Ship Registry Manx Shipping Notice SOLAS II-2 The Maintenance and inspection o

Attachment 1. to ClassNK Technical Information No. TEC-1077 Isle of Man Ship Registry Manx Shipping Notice SOLAS II-2 The Maintenance and inspection o Subject Periodical inspection, maintenance and tests of fire extinguishing system etc. on board for the Isle of Man flagged ships To whom it may concern Technical Information No. TEC-1077 Date 20 July

More information

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT FIRE SAFETY INSPECTION REPORT DANNY'S KNITWEAR LTD. ACCORD ID: 12228 SURABARI, GAZIPUR, SADAR, GAZIPUR Other Factories: ne October 17, 2015 Page 2 Fire Safety Inspection Report Introduction manufacturing

More information

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805) Oxnard Fire Department 360 W. Second Street Oxnard, CA 93030 (805) 385-7722 Fax (805) 385-8009 FIVE YEAR CERTIFICATION REPORT Service and maintenance report for automatic fire extinguishing systems, including

More information

Iranian Classification Society Convention and Legislation Department Code: Tech Contents

Iranian Classification Society Convention and Legislation Department Code: Tech Contents Page 2 of 12 Contents section A)Fire fighting appliances(ffa): 3 section B)Life saving appliances(lsa)... 9 section C)Attachements... 12 SECTION A) 1. General guide for Firefighting appliances(ffa): 1.1

More information

Essential Services and Inspection Guide Checklist

Essential Services and Inspection Guide Checklist Essential Services and Inspection Guide Checklist Foreword The provision of protection measures within buildings is essential to promote the safety of occupants and paramount for effective operation of

More information

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT Factory Address: Plot # 59-87, Adamjee Export Processing ZONE, Adamjee Nagar, Siddergonj, Narayangonj, Siddirgonj, Narayangonj Dhaka Bangladesh 09 Jun 2014 The

More information

Fire Safety Register

Fire Safety Register Fire Safety Register Introduction 1.1 Section 18(2) of the Fire Services Acts, 1981 and 2003 generally applies to all premises other than a dwelling house occupied as a single private dwelling. This section

More information

INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT INITIAL FIRE SAFETY ASSESSMENT Factory Address: Plot 1175 & 1179, Bashan Sarak, Vogra, PO. National University, Gazipur Sadar, Gazipur Gazipur Dhaka Bangladesh 15 Jun 2016 The Alliance for Bangladesh Worker

More information

Types of Detection. Fusible Link Detection - Most Common

Types of Detection. Fusible Link Detection - Most Common Types of Detection Fusible Link Detection - Most Common Types of Detection Electric Detection Types of Detection Pneumatic Detection-Tubing Pneumatic Tubing 3 Year Service life Survey Hazard 1) List all

More information

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers,

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers, NFPA CODE TESTING & INSPECTION Requirements & Recommendations for Licensed Florida Hospitals, Ambulatory Surgery Centers, ICF/IID Healthcare, & In-patient Hospice Facilities per NFPA Life Safety Code 101

More information

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY Revision No.: 11 Page 1 of 12 I. PURPOSE This procedure establishes a tool to help maintain a safe environment for all patients, visitors and staff by evaluating the loss of a life safety feature during

More information

2004 AUSTRALIAN STANDARDS UPDATE

2004 AUSTRALIAN STANDARDS UPDATE 2004 AUSTRALIAN STANDARDS UPDATE PREPARED by Peter Parsons Chairman of SAI FP-002 Chairman of ISO TC 21/SC 3 TSP Strategic Product Management Kjell Jawerth Chairman FPA Aust. TC/2 Member SAI FP-002 TSP

More information

Fire Safety in Communal Areas Policy

Fire Safety in Communal Areas Policy Fire Safety in Communal Areas Policy Date approved by senior management team 27 th July 2017 Board of Management / Committee name Board of Management Approval date 2 nd October 2017 Implementation date

More information

South Australian Regulatory Requirements

South Australian Regulatory Requirements South Australian Regulatory Requirements Australian Legislative Framework Act Act of Parliament Establishes the Law Primary legislation Regulation Subordinate legislation authorised by a specific Act Therefore

More information

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT Assessor: Konabari, Neelnagar, Gazipur Gazipur Dhaka Bangladesh Uttaron The Alliance for Bangladesh Worker Safety Page 1/13 Introduction to the Report The following

More information

FIRE SAFETY LOG BOOK

FIRE SAFETY LOG BOOK FIRE SAFETY LOG BOOK Regulatory Reform (Fire Safety) Order 2005 If you own, manage or operate a business, you will need to comply with fire safety law. The main law is the Regulatory Reform (Fire Safety)

More information

Government of Bermuda Department of Maritime Administration BERMUDA SHIPPING NOTICE

Government of Bermuda Department of Maritime Administration BERMUDA SHIPPING NOTICE Government of Bermuda Department of Maritime Administration 2015 028 BERMUDA SHIPPING NOTICE Maintenance, Testing and Inspection of Portable Fire Extinguishers Ref: SOLAS 74/88 as amended, Regulation II-2

More information

BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT

BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT Guidance and Instructions for Ship-owners, Managers, Masters, Bahamas Recognised Organisations and Bahamas Approved Nautical Inspectors Note: This

More information

FIRE SAFETY PLAN. Building Name. Address. Prepared By. Date Prepared. Page 1 of 36

FIRE SAFETY PLAN. Building Name. Address. Prepared By. Date Prepared. Page 1 of 36 FIRE SAFETY PLAN Building Name Address Prepared By Date Prepared Page 1 of 36 INTRODUCTION Fire safety is an important responsibility. The implementation of the fire safety plan helps to ensure effective

More information

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS (By authority conferred on the director of the department of licensing and regulatory affairs by sections

More information

Model: 400E-5M. Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset. Installation Operation Maintenance

Model: 400E-5M. Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset. Installation Operation Maintenance Model: 400E-5M Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset Installation Operation Maintenance Application Engineering Bermad 1. Safety First BERMAD believes

More information

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10 Belleville, Ontario Page 1 of 10 1 GENERAL 1.1 GENERAL REQUIREMENTS.1 The General Conditions of CCDC2-2008, and the General requirements of Division 1, form part of this Section and must read in conjunction

More information

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps. Issued 2006/08/01 Section 13920 Packaged Fire Pumps and Controllers Page 1 of 7 PART 1 GENERAL 1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1

More information

Draft FPA Australia Technical Specification for Public Comment FPAA101H DRAFT

Draft FPA Australia Technical Specification for Public Comment FPAA101H DRAFT Draft FPA Australia Technical Specification for Public Comment FPAA101H These preliminary pages provide information on the background to this Technical Specification, the system it covers and the context

More information

7.0 SAMPLE PERMITS, FORMS AND CHECKLISTS SELF INSPECTION CHECKLIST

7.0 SAMPLE PERMITS, FORMS AND CHECKLISTS SELF INSPECTION CHECKLIST 7.0 SAMPLE PERMITS, FORMS AND CHECKLISTS The Permits, forms and checklists shown within this section are an example of the type of controls that should be in place to help effectively manage Health & Safety

More information

Enclosure 4- RISK ASSESSMENT

Enclosure 4- RISK ASSESSMENT Enclosure 4- RISK ASSESSMENT RISK ASSESSMENT Risk is a potential that a chosen action or activity will lead to a loss of human or property. Risk assessment is a step for Risk Management. Risk assessment

More information

INTEGRATED LIFE SAFETY COMPLIANCE TESTING AND ITS PROCEDURES

INTEGRATED LIFE SAFETY COMPLIANCE TESTING AND ITS PROCEDURES INTEGRATED LIFE SAFETY COMPLIANCE TESTING AND ITS PROCEDURES By: Mehrdad Ghods Integrated Engineering Student Sept. 06, 2002 University of British Columbia Vancouver, BC i PREFACE: The purpose of this

More information

FIRE SAFETY SYSTEMS MAINTENANCE INFORMATION

FIRE SAFETY SYSTEMS MAINTENANCE INFORMATION FIRE SAFETY SYSTEMS MAINTENANCE INFORMATION To be kept in school administration office Crown Copyright, Province of Nova Scotia 2004 Prepared by Nova Scotia Department of Education No part of this document

More information

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST FIRE AND LIFE SAFETY SYSTEMS FOR STRUCTURES FIVE OR MORE STORIES IN HEIGHT AND LESS THAN 75 FEET IN HEIGHT FROM THE POINT

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 92 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Type Memo Tag FED - K9999 - FINAL OBSERVATIONS Title FINAL OBSERVATIONS Type Memo Tag FED - KA100 - General Requirements - Other Title

More information

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels The panels are designed in accordance with the requirements of EN54 Part 2:1997 (and include optional clauses

More information

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION INITIAL FIRE SAFETY ASSESSMENT - EXPANSION Factory Plot 47-52 & 68-73, KEPZ North Patenga Chittagong Chittagong 06 Mar 2017 The Alliance for Bangladesh Worker Safety Page 1/23 06 Mar 2017 Introduction

More information

FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures

FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures Building Name: Building Address: Plan Prepared By (please print): Date: Revision Date Comments Approval FIRE SAFETY MAINTENANCE

More information

Fire and Security Products and Services

Fire and Security Products and Services * www.redbooklive.com Fire and Security Products and Services Making LPCB Approval work for you Not all fire and security products and services on the market can be trusted in the event of a fire or attempted

More information

Home Maintenance Schedule

Home Maintenance Schedule Home Maintenance Schedule Regular Maintenance is the Key Inspecting your home on a regular basis and following good maintenance practices are the best way to protect your investment in your home. Whether

More information