Hitachi Elevator VFI-II

Size: px
Start display at page:

Download "Hitachi Elevator VFI-II"

Transcription

1 Hitachi Elevator VFI-II

2 Conventional model Hoistway Area of the machine room is at least twice the area of the elevator hoistway. The VFI-II elevator provides a comfortable ride appeals to different aspects of the human sense, touch, sight hearing - by the integration of button,tft(lcd) display, voice synthesizer multi-beam door sensor. PM motor VVVF door control Automatic dimming of indication light The brightness of the elevator hall car position indicator is dimmed automatically after a preset duration when elevator is idle. Automatic turn-off of car lighting fan In the event that the elevator is idle, the lighting ventilation fan in the elevator are automatically turned off to conserve energy. car using LED light car utilize LED light which consumes less energy. lanterns using LED light (optional) lanterns using LED light are available for your selection. Regenerative system (optional) Making use of the energy generated by an elevator when traveling downwards a heavy car load or wards a light car load, the traction machine acts as a power generator to transmit power back to the electrical network in the building. Energy saving operation control (applicable to FI-600 gro control only) As one of the stard functions of the FI-600 gro control system. The operation reduces energy consumption of elevators by forecasting the traveling routes occancy rate of elevators during low traffic. Sight TFT(LCD) position indicator Floor button flashing function The registered car destination floor button flashes when the car approaches the destination floor The human touch Multi-beam door sensor In the event where the beam paths are obstructed, this sensor, installed on the edge of the doors, will keep the doors open. Hearing Voice synthesizer (optional) Preset stard messages are announced to the passengers by a voice synthesizer. 2 3

3 VIB-15B button indicator type TFT(LCD) VIB-13B button indicator type Dot matrix OPE-15B Operating type TFT(LCD) DHP-OP13 Operating type Dot matrix TFT(LCD), incorporated into car 4 5

4 s ceilings OPE-15B OPE-15B TFT(LCD), incorporated into car TFT(LCD), incorporated into car 6 7

5 Operating s Jamb frame SS-1X (wide) type, mirror Door s mirror etched Ling sill Extruded hard aluminum OPE-15B type TFT(LCD) OPS type Dot matrix DHP-OP13 type Dot matrix Position indicator 8 9

6 DHB-A DHB-A DHB-A DHB-A DHB-A DHB-A DHB-A DHB-A DHB-A DHB-A 10 && && && && && && & accessibility accessibility code code of of Singapore Singapore (,). (,). accessibility accessibility code code of of Singapore Singapore Singapore (,). (,). light light accessibility accessibility code code of of Singapore (,). (,). light light light light accessibility code code of of Singapore Singapore (,). (,). accessibility light light accessibility accessibility code code of of Singapore Singapore (,). (,). light light Red(RH) Red(RH) (GH) (GH) accessibility accessibility code code of of Singapore Singapore (,). (,). Red(RH) Red(RH) (GH) Red(RH) Red(RH) (GH) (GH) (GH) accessibility code of Singapore (,). light light comply accessibility code of Singapore. light light Red(RH) Red(RH) (GH) (GH) Red(RH) Red(RH) 42mm(W) 42mm(W) 37mm(H) 37mm(H) 42mm(W) 42mm(W) 37mm(H) 37mm(H) 42mm(W) 42mm(W) 37mm(H) 37mm(H) Red(RH) Red(RH) Red(RH) 42mm(W) 42mm(W) 37mm(H) 37mm(H) 42mm(W) 42mm(W) 37mm(H) 37mm(H) (GH) (GH) (GH) (GH) (GH) 11

7 indicators HF-15 HSDX TFT(LCD) Dot matrix Indicator hall lantern VIB-15B (For simplex operation) VIB-15BD (For dlex operation) VIB-13B (For simplex operation) VIB-13BD (For dlex operation) HLS-025SD Dot matrix type type TFT(LCD) Dot matrix VLS-115S VLS-90S Vertical hall lantern Vertical hall lantern BL() BL() BL() HLS-025S L-03 type type type Horizontal hall lantern Horizontal hall lantern 12 13

8 14 15

9 FI series FI series No. Function Description Centralized control for special floors (FI-CCF) Service floor selection (FI-SFS) VIP service(*1) (FI-VIP) Closest car priority service (FI-CPS) Scheduled reservation system (FI-SRS) Zoning express service (FI-EZS) Independent automatic operation(*1) (FI-IAO) This function preferentially assigns an elevator to the special floor (e.g. the director s room). Allows the operator to select the service non-service floors using, for example, the switches on the control. When welcoming or sending off important guests, this function permits an elevator to be summoned directly to the desired car call floor by pushing a specially provided hall button. When a hall call button is pressed, the elevator car in the shaft closest to the hall call floor is preferentially dispatched. Allows the operator to schedule various elevator services in the building, including the reassignment of service floors, centralized service priority service, at a specific date time (setting through XEMS is also possible). Starts a divided express service when the peak traffic dem takes place in the preset time zones. This operation allows an elevator to be separated from the gro servisory control operate independently by a separate hall button. Destination floor reservation 27 system FIBEE (FI-DFRS) (*1) Not applicable for (FI-DFRS) Allows the passenger to preselect the destination floor on the destination floor installed at the ling hall. This reduces button operations to one, improving the operability

10 No. Name Description STD OPT Simplex collective control (CCTL) Dlex collective control (DCTL) FI-600 Gro 4 FI-100 control 5 FI-10 6 Down collective control (DWCC) 7 Attendant operation(att) 8 Independent operation (INOC) This is a fully automatic operation used for a single elevator system. calls in the direction in which the elevator is travelling are responded to sequentially when all calls in that direction are cleared, calls in the opposite direction are responded to. When there are no more calls, the elevator will stop at the last floor served. This is a fully automatic operation used for a two-elevator system. calls are responded to by whichever elevator that can serve the hall call faster. When there are no more calls, one of the elevators will st-by at the start floor while the other elevator will stay at the last floor served. This is a gro control system used to operate three to eight elevators in a large-sized building. This control system consists of 3 smart systems; future reference-trajectory control, learning system intelligent system. This is a gro control system used to operate three to six elevators in a medium-sized building. This control system uses reference-trajectory control, which is based on the theory used in the highest model of the future reference-trajectory control. This is a simplified gro control system used to operate three or four elevators. The system provides a ring control to allocate the elevator car closed to the floor where a new hall call is registered. For this system, all floors have down call only, except for the start floor, where there is call button only. The other operations are the same as in selective-collective dlex selective-collective operations. For this system, the stop floor is manually set by an attendant, such as in a department store. This operation system is used when there is a need to serve special passengers. Under this operation, all hall calls are disabledfor the elevator it is reserved for exclusive use of the special passengers. No. Name Description STD OPT Mischievous call cancellation (MCCC) Automatic door open time adjustment(dtad) Floor deselect function (FDSF) 4 Automatic return function (ARTF) 5 floor button flashing (CCBF) 6 Door open prolong button(dopb) 7 8 Automatic bypass Operation(ABPO) Keypad sub- board(ksop) 9 Sub- (SOPB) 10 Voice synthesizer (VSYS) 11 Arrival signal(asgn) Depending on your requirements the number of elevators in a gro, customers can choose from a range of collective control systems, gro control systems (including FI-series gro control system) systems. There are also basic optional functions which you can choose from, depending on the building type building requirements. Service functions Interfacing BGM speaker (BGMS) Emergency Battery Operated Power Sply(EBOPS) In the event that a large number of calls is registered by a small number of passengers, the calls are determined to be mischievous will be automatically cancelled on responding to the next call. This thus eliminates unnecessary stops. The duration of the door open timing is tailored to usage conditions, substantially improving operational efficiency. This function allows passenger to cancel the selection of a floor which is accidentally pressed by pressing the button again. (This thus eliminates unnecessary stops.) After all the calls have been served, the elevator will return to the start floor for st-by. The registered car destination floor button flashes when the car approaches the destination floor. In the event that this button on the car operation board is pressed, the elevator doors remain open for a pre-set period of time. In the event that the elevator is fully loaded, this operation will not respond to any hall calls will only respond to the car calls. In order to comply the code, especially for high-rise buildings, individual car call can be replaced by a keypad system. Additional floor selection door open/close are located on the opposite side of the main in the elevator. This will be extremely convenient during rush hours. Preset stard messages are announced to the passengers by a voice synthesizer. An electronic chime (located at the top bottom of the elevator) will be sound just before the arrival of the elevator. A speaker for background music public announcements for the building can be installed in the elevator. (Music announcement systems, including wiring, is to be provided by others) In the event of a power failure, this emergency sply will allows the operation of a light, fan alarm bell. Legend STD Stard OPT Optional Legend STD Stard OPT Optional No. Name Description STD OPT 1 Multi-beam door sensor(mbds) 2 No. Name Description STD OPT Automatic turn-off of elevator In the event that the elevator is not in use, the light ventilation fan in 1 light fan(atfl) the elevator are automatically turned off to conserve energy. In the event that elevator maintenance is being carried out, the elevator 2 Maintenance operation(mtno) operates at a lower speed. 3 Parking operation(pkgo) The elevator can be parked at the designated floor a key switch. 4 Rush-hour schedule operation(rhso) All the elevators will automatically return to the start floor, after serving the last call during this preset rush-hour timing. 5 Floor lock-out operation(fllo) Specific service floors can be locked-out by activating a switch Floor lock-out operation by cipher code (ROCC) Intelligent operation security system (IPSS) Interfacing closed-circuit TV (CCTV) 9 Servisory (SVP) Door safety return system (ORS) 3 Interphone system(inps) 4 emergency lighting(ceml) Nearest ling operation(nlno) Overload detection system(olds) Door safety edge (both sides or one side)(dseb) 8 3D door safety device(3dds) Safety functions Abnormal speed protection function(aspf) Out of door-open zone alarm (ASOZ) Overvoltage detection system, (OVDS) Extensible elevator monitoring system (XEMS) Interfacing to building management system (BMS) 12 Regenerative system (RGNS) In the event that the beam paths are obstructed, this sensor, installed at the edge of the doors, will keep the doors open. In the event of door overload, such as when passengers get their fingers, hs or personal belongings caught in the door, this system automatically senses this either re-closes or re-opens the doors to prevent injury. An interphone system is provided for emergency communication between the elevator the master unit (in the servisory, etc.). In the event of a power failure, an emergency light inside the elevator will be automatically activated. In the unlikely event of temporary trouble during operation, the elevator automatically goes to the nearest floor at a low speed doors will open to prevent passengers from being trapped inside. In the event of overloading, this system will activate an audio/ visual signal to prevent the elevator from moving. Mechanical safety units are installed on both sides or one side of the elevator doors. In the event of passengers coming into contact the safety edges of closing doors, the doors will immediately reopen. This device detects passengers getting on or off the elevator, keeping the doors open as long as passengers are in the area of detection In the event that the elevator is moving downwards at an abnormally high speed, the breakers will be automatically engaged the elevator will cease operation. In the event that the elevator stops out of the door open zone of a selected floor, doors will not open, an alarm will be sounded in the elevator. When an abnormal increase in power sply to the elevator system is detected, the power sply will be cut off to prevent damages to the elevator equipment. 12 Fire rated ling door 2 hours fire rated ling door are available where required Management functions By inputting a pre-programmed code using the car board floor, passengers can gain access to certain restricted floors. This function allows controlled access to certain floors by means of a password or ID cards. Note Keypad or ID card-reader system is to be provided installed by others. Interfacing shall be by means of dry (voltage-free) contacts. This system enables the security personnel to monitor the movement inside the elevator. This will be effective in preventing criminal mischievous acts inside the elevator. (CCTV system, including wiring, is to be splied by others.) This provides various servisory operations, including communication status monitoring. This system shows the real time situation of the elevators such as the elevator position, movement direction abnormal operation on the PC (Personal Computer) display. It is also possible to turn on/off the elevators change the service floors of the elevators using the PC. This interfacing shall be done by means of electrical dry contact to the building management system for their monitoring. When traveling downwards a heavy car load or wards a light car load, the traction machine acts as a power generator to transmit power back to the electrical network in the building. Legend STD Stard OPT Optional Legend STD Stard OPT Optional 18 19

11 Emergency operations No. Name Description STD OPT Earthquake emergency operation (EEMO) Fire emergency operation(femo) Emergency operation for power failure (EPFO) Automatic rescue device for power failure (ALP 5 Fireman operation(fmno) In the event that an earthquake is detected, the elevator will stop at the nearest floor. (This function is not applicable to private lobby layouts.) In the event of fire, the elevator is automatically brought to the designated floor where it remains inoperative for passengers safety. In the event of building power failure, the elevator can be operated by the building stby generator to move the elevator to the designated floor. In the event of building power failure, the elevator automatically switches to battery power to bring itself to the nearest floor. (This function is not applicable to private lobby layout buildings.) In the event that the fireman switch is turned on, the elevator returns to the designated floor will be ready for firemen s use. Legend STD Stard OPT Optional No. Item Finishes/ Designs/ Types STD OPT 1 Painted Sheet Steel 2 Steel Hairline Narrow Type (AS-1X) 3 Steel Non-directional Hairline 4 Steel Mirror 5 Painted Sheet Steel 6 Jamb Without Transom (TS-1X) Steel Hairline T-Wide Type 7 Frame With Transom (TL-2X) Steel Non-directional Hairline Legend STD Stard OPT Optional 8 Steel Mirror 9 Painted Sheet Steel No. Item Finishes/ Designs/ Types STD OPT 1 CS-Series (CS-101S) 2 Ceiling DX-Series (DX-201S) (DX-12S) (DX-23S) 3 SL-Series / EX-Series (SL-102S) (EX-32S) (EX-403S) 4 Painted Sheet Steel 5 Steel Hairline Wall (3 sides) 6 Steel Non-directional Hairline 7 Steel Hairline Etched (Hitachi Stard Pattern) 8 Steel Hairline 9 Front Return Steel Non-directional Hairline 10 Transom Steel Hairline Etched (Hitachi Stard Pattern) 11 Steel Mirror 12 Steel Hairline 13 Steel Non-directional Hairline Door 14 Steel Hairline Etched (Hitachi Stard Pattern) 15 Steel Mirror 16 Kickplate (3 sides) Steel Hairline 17 Sill Extruded Hard Aluminum 18 Steel Hairline TFT (LCD) Indicator (OPE-15B) 19 Position Indicator Steel Hairline Dot Matrix Indicator (DHP-OP13) 20 Operating Steel Hairline Dot Matrix Indicator (OPS) 21 Steel Face Plate out () () Legend STD Stard OPT Optional 10 Without Transom (SS-1X) Steel Hairline S-Wide Type 11 With Transom (SL-2X) Steel Non-directional Hairline 12 Steel Mirror 13 Sill Extruded Hard Aluminum 14 Painted Sheet Steel 15 Steel Hairline 16 Steel Non-directional Hairline Door 17 Steel Hairline Etched (Hitachi Stard Pattern) 18 Steel Mirror 19 Steel Mirror Etched (Hitachi Stard Pattern) 20 Incorporated Clip/Screw Type TFT(LCD) (VIB-15B) (VIB-15BD) 21 Type Clip/Screw Type Dot Matrix (VIB-13B) (VIB-13BD) 22 Clip/Screw Type (BL) Indicator (*1) 23 Clip/Screw Type TFT(LCD) (HF-15) Indicator 24 Clip/Screw Type Dot Matrix (HSDX) (HSL-025SD) 25 Steel Surface Plate out () () 26 Steel Surface Plate out () () 27 Steel Surface Plate () () () () 28 Vertical Type (VLS-115S) (VLS-90S) 29 Lantern Horizontal Type (HLS-025S) (L-03) 30 (HLS-025SD) (*1) indicator is not recommended for gro control system FI-100 FI Steel Face Plate out () () 23 Steel Face Plate () () () () 20 21

12 The modern manufacturing plant in South East Asia, Singapore Thail, provide valuable product to customer. Equipment is made to the highest stard of quality reliability cutting-edge production line. Excellence flexibility in design at manufacturing plant in Singapore Thail CERT NO ISO CERT NO ISO This modern manufacturing plant in Singapore boasts a complete team of local Japanese engineers geared towards providing maximum flexibility in design manufacturing to suit the customer requirements. Hitachi Elevator Asia Pte Ltd (Singapore) High accuracy efficiency in planning of equipment layout is made possible by the most advanced CAD system. Equipment is made to the highest stard of quality reliability modern CNC machinery. Siam Hitachi Elevator Co., Ltd. (Thail) An integrated engineering system - from development to design production Head office, research centers plants work closely together to develop new technologies Staff throughout the company work together as one team to conduct research develop technologies. TS-1X type jamb (optional) High performance simulator enhances overall elevator system efficiency A high performance simulator is utilized for all stages of elevator development, from planning through system design. Planning, research development are carried out according to the results of this statistical analysis. Mito Works, Hitachi, Ltd. (Japan) Cutting-edge CAD/CAM systems The latest in CAD/CAM systems help us carry out elevator layout various other design production steps more quickly efficiently. One of the tallest elevator research tower. (Left conceptual drawing) Hitachi plans to research develop the ultra-high speed (1,000 m/min more) large-capacity (5,000kg more) elevators. EC97J1015 JQA-QMA0669 Mito Works, Urban Planning Development Systems Company, Hitachi, Ltd. has acquired the certification of ISO14001(Environmental Management System) ISO9001(Quality Management System). 22 Note Colors reproduced here may vary slightly from the actual. 23

13 The preparatory work for elevator installation outlined in below table should be undertaken by building contractors in accordance Hitachi drawings in compliance local or relevant codes regulations. C C C C 24 25

14 Min Min M/C Min M/C M/C Room Room Room Height Height Total Total Total Height Height Overhead Overhead Pit Pit Depth Pit Depth Depth Travel Travel Top floor Hoistway machine Top Floor room layout Min Machine room height MH Total height Entrance Entrance Height Height Overhead height Top Floor Top Floor Top Floor Pit depth Travel Lowest Floor Lowest Floor Lowest Floor (*1)Hoisting Hook (*1)Hoisting Hook (*1)Hoisting (By others) Hook (By others) (By others) Entrance height Top floor Lowest floor Ladder, lighting & outlet (By others) Hoisting hook (By others) PLF PLF PLF Height Height PLF height R3 R1 R1 R1 R4 R1 Ventilation Ventilation grille grille grille (By (By others) (By others) Machine room width S Machineroom width R1 Ladder, lighting & outlet (By others) Ladder, lighting & outlet (By others) inside width a inside width inside width a R3 R4 Minimum dimensions R3 R4for overhead height, pit depth other specifications R3 R4 No. Rated load (kg) Rated speed (m/min) Travel (m) inside inside inside depth depth depth b b b Optional Optional Optional R3 Control Control R3 Control R3 R4 Hoistway Hoistway depth depth depth Y Y Y Ventilation Ventilation fan fan fan (By (By others) (By others) Entrance door door (By (By others) (By others) Machine Machine room room room depth depth depth T T T Note Machine room temperature should be maintained R3 below R4 38 o C Note Machine ventilating room temperature fan or air conditioner. should be maintained below 38 o C Note Machine ventilating room temperature fan or air conditioner. should be maintained below 38 o C ventilating fan or air conditioner. No. Hoistway widthx Hoistway widthx Hoistway widthx Minimum machine room height & hoisting hook capacity Rated load (kg) Rated speed (m/min) Min. Machine room height MH (mm) Hoistway width X Hoistway width Hoistway width X inside width a inside width inside width a Door OP width Door OP width Door OP width ~ , 90, 105, 120, Door OP width Door OP width Door OP width inside inside inside depth depth depth b b b Hoisting hook capacity (Ton) 1 450~700 60, 90, , 90, ~ , , 90, 105, 120, Overhead height (mm) (*1) SS550/ EN81-1/Malaysia India/Hitachi Std /HKG COP KFB Pit depth (mm) Maximum number of stops Travel max Travel max ~ Travel max Travel max Travel max ~1050 Travel < Travel max Travel < Travel max Travel max Travel max ~1350 Travel < Travel max Travel < Travel max Travel max Travel max Total Total Height Height Overhead Overhead Pit Depth Pit Depth Travel Travel Total Total height height Entrance Entrance Height Height R1 Overhead Overhead height heig Top Floor Pit depth Pit depth Travel Travel Entrance Entrance height height Lowest Floor Lowest Floor Top floor Lowest floor Lowest floor Travel < Travel max Travel < Travel max PLF PLF Height Height PLF PLF height height R1 R1 u R4 R Optional Minimum floor to floor height (mm) 2700 Control Control Hoistway Hoistway depth depth depth Y Y Y Ventilation Ventilation fan fan (By others) (By others) Hoistway Width, HW X Note Machine room temperature should be maintained below 38 o C ventilating fan Hoistway or air conditioner. Width, HW X Note Machine room temperature should be maintained below 38 o C ventilating fan or air conditioner. Inside width a Inside width a Opening OP Opening OP Optional Inside Inside Depth Depth b b Optional Optional Control Control Hoistway Hoistway Depth, Depth, Y Y Machine Ventilation Machine Ventilation room roo Fan de (By others) (By VFI-II (*1) Minimum overhead height shall be increased by 350mm if car inside depth is less than 1100mm additionally increase by 200mm if the ceiling design is EX-series type Mach

15 Hitachi Elevator Asia Pte. Ltd. 10 Toh Guan Road East Hitachi Elevator Building Singapore Tel (65) http// Distributor Specifications designs in this catalogue are subjected to change out notice. Printed on recycled paper. Please recycle. HEES-007(4) 1217 (PIS)

SIGMA MRL E1000.

SIGMA MRL E1000. SIGMA MRL E www.sigmaelevator.com Lifting up Trust Our dedication and passion to reach customer satisfaction always have been a driving force of our creative and innovative ideas. As your elevator partner,

More information

Creating a New History

Creating a New History Creating a New History Hitachi Group is active in a wide range of business sectors. From the technology and experience built up over many years, come the synergies that feed new innovation. Hitachi has

More information

Creating a New History

Creating a New History Creating a New History Hitachi Group is active in a wide range of business sectors. From the technology and experience built up over many years, come the synergies that feed new innovation. Hitachi has

More information

Since giving rise to the elevator industry more than 150 years ago, Otis has been at the forefront of elevator technology.

Since giving rise to the elevator industry more than 150 years ago, Otis has been at the forefront of elevator technology. OTIS SKY Since giving rise to the elevator industry more than 150 years ago, Otis has been at the forefront of elevator technology. Through the years, Otis team of professional engineers and designers

More information

Car Design. Contents. Design. Car. Hall Design. Observation Cars NEXIEZ - MRL Only. Materials and Colors. Ceiling Variation & Car Finish 3-10

Car Design. Contents. Design. Car. Hall Design. Observation Cars NEXIEZ - MRL Only. Materials and Colors. Ceiling Variation & Car Finish 3-10 PASSENGER ELEVATORS Contents Car Design 2-13 Ceiling Variation & Car Finish 3-10 Car Operating Panels 11-12 Interior 13 Hall Design 14-18 Entrance Finish 15-16 Hall Signal Fixtures 17-18 Car Design NEXIEZ

More information

DESTINATION BASED DISPATCHING FIXTURES & DISPLAYS

DESTINATION BASED DISPATCHING FIXTURES & DISPLAYS DESTINATION BASED DISPATCHING FIXTURES & DISPLAYS Contents The Motion Advantage 3 Destination Entry 4-5 At the Car 6-7 In the Car 8-9 Specifications 10-15 The Motion Advantage With sales of more than 180,000

More information

ELEVATOR UPGRADE AND MODERNIZATION

ELEVATOR UPGRADE AND MODERNIZATION BOYLE COUNTY COURTHOUSE ELEVATOR UPGRADE AND MODERNIZATION SPECIFICATIONS 1-1-2017 1 ON Provide labor and material to furnish and install the following: SECTION I. SYSTEM OPERATING FEATURES DUTY The present

More information

SECTION ELECTRIC TRACTION ELEVATORS PART 1 GENERAL 1.01 SUMMARY. A. Section Includes: Electric Traction Elevators.

SECTION ELECTRIC TRACTION ELEVATORS PART 1 GENERAL 1.01 SUMMARY. A. Section Includes: Electric Traction Elevators. SECTION 142200 - ELECTRIC TRACTION ELEVATORS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Electric Traction Elevators. B. Products Supplied But Not Installed Under this Section: 1. Hoist Beam 2. Pit

More information

Home Elevators for Private House

Home Elevators for Private House Home Elevators for Private House Luxury and convenience in your home MODEL Series-SVC/SED Raising the Quality of Your Lifestyle Home elevators empower everyone in your family to move around the home with

More information

Contents. Principle. Ceiling Design Signal Fixtures. Interior. Hall Design. Observation Cars NEXIEZ - MRL only. Materials and Colors

Contents. Principle. Ceiling Design Signal Fixtures. Interior. Hall Design. Observation Cars NEXIEZ - MRL only. Materials and Colors PASSENGER ELEVATORS Principle Based on our policy, Quality in Motion, we provide elevators and escalators that will satisfy our customers with high levels of comfort, efficiency, ecology and safety. Contents

More information

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description TrueCom Building Communications Systems 5115-Series 5115-9001, -9002 Area of Rescue Communications System Description The Simplex 5115-9001 and -9002 Area of Rescue Communications System provides buildings

More information

ThyssenKrupp Elevator Americas. owner s guide

ThyssenKrupp Elevator Americas. owner s guide ThyssenKrupp Elevator Americas owner s guide protecting your investment Elevators and escalators are a significant capital investment, and they influence your building s marketability based on their performance

More information

Port of Portland Conveying Equipment Guidelines

Port of Portland Conveying Equipment Guidelines Role: Consultant for the Port Design Guidelines Port of Portland Conveying Equipment Guidelines ELEVATOR, ESCALATOR, AND MOVING WALK DESIGN OVERVIEW The Division 14 specification sections include appropriate

More information

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM EN60849/IEC60849 compliant VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM Full compliance with EN60849/IEC60849 standards System status can be confirmed on Remote Microphones Fireman s Microphone included

More information

PASSENGER ELEVATORS Series-MR

PASSENGER ELEVATORS Series-MR PAENGER ELEVATR eries-mr technologically advanced elevators that consume less power, have minimal impact on the global environment and harmoniously serve people and buildings with smooth, seamless operation.

More information

REVA Linen Finish Car Operating Panel

REVA Linen Finish Car Operating Panel REVA REVA Linen Finish Car Operating Panel RV 01 RV 03 RV 02 RV 04 RV 06 RV 05 RV 07 5 2 REVA REVA Hairline Finish Car Operating Panel RH 01 RH 03 RH 02 RH 04 RH 06 RH 05 RH 07 REVA REVA Gold Finish Car

More information

TST Portable Event Logger &Programmer for UML-51 Controllers v15.6

TST Portable Event Logger &Programmer for UML-51 Controllers v15.6 P.O.B 1180, Kfar saba 44111, israel Plant: 3 Hayozma St. Kfar saba, Israel Tel: +972-9-7676881 Fax: +972-9-7676882 www.leeav.co.il E.mail :lsales@leeav.co.il TST Portable Event Logger &Programmer for UML-51

More information

PASSENGER ELEVATORS MACHINE-ROOM-LESS SYSTEM

PASSENGER ELEVATORS MACHINE-ROOM-LESS SYSTEM PAENGER ELEVATR MACHINE-RM-LE YTEM Principle Based on our policy, Quality in Motion, we provide elevators and escalators that will satisfy our customers with high levels of comfort, efficiency, ecology

More information

PA/VA solutions for transport industry

PA/VA solutions for transport industry PA/VA solutions for transport industry Public Address Voice Evacuation System EN 54-16 EN 54-4 EN 54-24 e make everyday life safer www.ambientsystem.eu TECHNICAL SUPPORT ROOM CONTROL ROOM PA/VA Solutions

More information

本カタログのオリジナル版は 中文版です 本英語版PDFは ELENESSA

本カタログのオリジナル版は 中文版です 本英語版PDFは ELENESSA PASSENGER ELEVATORS Principle Based on our policy, Quality in Motion, we provide elevators and escalators that will satisfy our customers with high levels of comfort, efficiency, ecology and safety. Contents

More information

APPENDIX K MODIFIED INDUSTRY STANDARDS FOR ELEVATORS AND CONVEYING SYSTEMS

APPENDIX K MODIFIED INDUSTRY STANDARDS FOR ELEVATORS AND CONVEYING SYSTEMS APPENDIX K MODIFIED INDUSTRY STANDARDS FOR ELEVATORS AND CONVEYING SYSTEMS CHAPTER K1 MODIFICATIONS TO ASME A17.1-2000, SAFETY CODE FOR ELEVATORS AND ESCALATORS K101.1 General. As referenced by Chapter

More information

Contents. Principle. Ceiling Design Signal Fixtures. Interior. Hall Design. Observation Cars NEXIEZ - MRL Only. Materials and Colors

Contents. Principle. Ceiling Design Signal Fixtures. Interior. Hall Design. Observation Cars NEXIEZ - MRL Only. Materials and Colors PASSENGER ELEVATORS Principle Based on our policy, Quality in Motion, we provide elevators and escalators that will satisfy our customers with high levels of comfort, efficiency, ecology and safety. Contents

More information

Emergency Power & Fire Service Checklist

Emergency Power & Fire Service Checklist Emergency Power & Fire Service Checklist www.technicalsafetybc.ca contact@technicalsafetybc.ca Toll Free: 1 866 566 7233 The intended purpose of this form is to provide a mechanism for inspectors to be

More information

Smart Homes in. Rajya Sabha Co-operative Housing Society

Smart Homes in. Rajya Sabha Co-operative Housing Society Smart Homes in Rajya Sabha Co-operative Housing Society Construction Partners Technical Partners for Smart Society & Homes Introduction Categories Online Enhanced Security Residents Communication Alerts

More information

Summit 3208GLD USER MANUAL. Electronics Line

Summit 3208GLD USER MANUAL. Electronics Line Summit 3208GLD USER MANUAL Electronics Line Table of Contents 1: Introduction... 2 2: Overview... 3 3: Keypad Functions... 4 3.1: Keypads... 4 3.2: 3108 LCD Keypad Layout... 4 4: Basic System Operation...

More information

sirens speakers and programmable controls

sirens speakers and programmable controls GLOBAL WARNING WWW.HAZTEC.UK sirens speakers and programmable controls 3 SEPTEMBER 2015 1 warning lights, work lights and ancillaries see separate brochure (1) 2 lightbar range overview see separate brochure

More information

sirens speakers and programmable controls

sirens speakers and programmable controls GLOBAL WARNING WWW.HAZTEC.UK sirens speakers and programmable controls 3 march 2016 1 warning lights, work lights and ancillaries see separate brochure (1) 2 lightbar range overview see separate brochure

More information

U ser's Guide PC6010

U ser's Guide PC6010 User's Guide PC6010 Quick Reference Guide This manual is for Basic and Advanced users. Each of these types of user can access a different set of functions. The and symbols next to the title of each procedure

More information

GREEN LIFT SYSTEM USE MANUAL WITH PERMANENT MAGNETS * EN* SYSTEM TYPE: q GLPM MRL 1:1 q GLPM MRL 2: EN.

GREEN LIFT SYSTEM USE MANUAL WITH PERMANENT MAGNETS * EN* SYSTEM TYPE: q GLPM MRL 1:1 q GLPM MRL 2: EN. Italiano GLB SELL TECH WORK OWNER USER GREEN LIFT SYSTEM WITH PERMANENT MAGNETS 10991792 EN *10991792EN* SYSTEM TYPE: q GLPM MRL 1:1 q GLPM MRL 2:1 ORIGINAL INSTRUCTIONS Verified by GMV Spa GMV SPA FLUID

More information

4286/4500 Voice Module Set up and Troubleshooting

4286/4500 Voice Module Set up and Troubleshooting 4286/4500 Voice Module Set up and Troubleshooting In this document we will discuss the following: 1. Pre-Installation Notes 2. The Wiring 3. System Programming 4. 4286 1 st Time Accessing and Programming

More information

Memcom Emergency Telephone

Memcom Emergency Telephone Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming

More information

N-8000 SERIES IP INTERCOM SYSTEM

N-8000 SERIES IP INTERCOM SYSTEM N-8000 SERIES IP INTERCOM SYSTEM IP Network-Compatible Intercom System with Packet Audio Technology developed with cutting-edge TOA technological strengths for greater versatility and improved sound quality

More information

Gallagher System Integrations

Gallagher System Integrations Gallagher System Integrations Gallagher Command Centre supports integrations with a range of third party security products, using Gallagher developed interface software and industry standard protocols.

More information

Security System With Scheduling. User Guide. N5943-8V4 7/04 Rev A

Security System With Scheduling. User Guide. N5943-8V4 7/04 Rev A ADEMCO VISTA-120 Security System With Scheduling User Guide N5943-8V4 7/04 Rev A Your Honeywell security system is designed for use with devices manufactured or approved by Honeywell for use with your

More information

Solutions for Mass Notification Systems

Solutions for Mass Notification Systems Solutions for Mass Notification Systems Emergency Voice Alarm Systems with Paging and Background Music Functions 8 decades of Sound & Communication and 4 decades of Voice Alarm Experience Boutique Passage

More information

MAY 2016 Elevator QEI & Maintenance Performance Report

MAY 2016 Elevator QEI & Maintenance Performance Report MAY 2016 Elevator QEI & Maintenance Performance Report SOUTH PASSENGER ELEVATORS 4 & 5 JUNEAU SQUARE 809 E WISCONSIN AVENUE MILWAUKEE, WISCONSIN BY: ELEVATOR CONSULTING SERVICES, INC. Equipment Inventory

More information

OWNER S MANUAL CLEANING ROBOT

OWNER S MANUAL CLEANING ROBOT OWNER S MANUAL CLEANING ROBOT Before using, please carefully read the Safety Precautions pages to allow for safe operation of the product. After reading the operation manual, please keep it in an easily

More information

2000 Series. Program Entry Guide. Control Panels

2000 Series. Program Entry Guide. Control Panels 2000 Series EN Program Entry Guide Control Panels 2000 Series Program Entry Guide About This Manual EN 2 About This Manual This guide describes the programming parameters available to the 2000 Series Control

More information

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

**** **** A B ARMED FIRE FIRE C D READY OFF AWAY STAY 2 3 MAXIMUM TEST BYPASS PULL INSTANT CODE CHIME. First Alert READY. * 0 # Professional

**** **** A B ARMED FIRE FIRE C D READY OFF AWAY STAY 2 3 MAXIMUM TEST BYPASS PULL INSTANT CODE CHIME. First Alert READY. * 0 # Professional ARMED READY READY )$&&$&% )LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHPV ZLWK6FKHGXOLQJ **** **** A B C D FIRE FIRE First Alert OFF AWAY STAY 2 3 1 4 5 6 7 8 9 MAXIMUM TEST BYPASS INSTANT CODE CHIME * 0 #

More information

The Owner will provide the QEI inspection and certification services.

The Owner will provide the QEI inspection and certification services. General The Owner will provide the QEI inspection and certification services. Elevators Electric operated traction elevators are preferred; holeless hydraulic oil operation may be considered where use

More information

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad.

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad. SYSTEM USER GUIDE SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad. IS THIS A FALSE ALARM? YES NO displays. REAL ALARM If

More information

Table of Contents. Appendix A Special Characters 31

Table of Contents. Appendix A Special Characters 31 Table of Contents Introduction 2 Section 1: General System Operation 3 1.1 Getting to Know Your System... 3 1.2 How to Arm... 4 1.3 Alternate Arming Methods... 5 1.4 Disarming... 6 1.5 Alarm Memory...

More information

PC4020 v3.2 Instruction Manual

PC4020 v3.2 Instruction Manual PC4020 v3.2 Instruction Manual WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire

More information

NX-148 LCD CODE PAD TABLE OF CONTENTS

NX-148 LCD CODE PAD TABLE OF CONTENTS NX-148 LCD CODE PAD TABLE OF CONTENTS Glossary Of Terms... 4 Understanding The Lights... 5 Code Pad Functions Arming In The ON Mode... 6 Making The System Ready To Arm... 7 Using Quick Arm... 7 Arming

More information

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2 Division 28 ELECTRONIC SAFETY AND SECURITY TABLE OF CONTENTS 28 0000 GENERAL... 2 A. DEFINITIONS...2 28 3111 DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2 A. DESIGN REQUIREMENTS...2 B. CONSTRUCTION REQUIREMENTS...2

More information

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully

More information

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM CPD No. 1134-CPD-110. CPD No. 1134-CPD-083. Fully EN 54 certified Voice Alarm emergency evacuation system with Public Address broadcast capability The

More information

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00 INHEP DIGITAL IDS S E C U R I T Y IDS816 User Manual MANUAL NO. 700-283-01 B ISSUED DEC 2004 VERSION 2.00 Contents 1. Introduction to the IDS816... 4 2. Understanding the Keypad Indicators... 4 3. Programmable

More information

Installation of a new engineered HYDRAULIC elevator complete as described in this standard.

Installation of a new engineered HYDRAULIC elevator complete as described in this standard. DIVISION 14 - CONVEYING SYSTEMS Section 14240 - Hydraulic Elevators WORK INCLUDED Installation of a new engineered HYDRAULIC elevator complete as described in this standard. SUBMITTAL'S Submit bound operation

More information

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ READY ARMED READY 1 OFF 7 INSTANT READY 2 AWAY 8 CODE 6BYPASS 9 CHIME 9,67$% &RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ 8VHU*XLGH ARMED READY 1 OFF 2 AWAY 3 STAY 4 MAX 5 TEST 6 BYPASS

More information

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE Effective Date: 11/01/02 Purpose: MECKLENBURG COUNTY To establish a set of guidelines for performance testing of all newly installed or upgraded fire alarm systems in order to ensure that all devices and

More information

For Dealers / Integrators / Architects. IS Series. Video Intercom. Building Communication. Controlling Security.

For Dealers / Integrators / Architects. IS Series. Video Intercom. Building Communication. Controlling Security. For Dealers / Integrators / Architects IS Series Video Intercom Building Communication. Controlling Security. IS Series helps save money Control multiple functions from any location to help reduce overall

More information

EURO 46 APP. User Manual. Connect to your home or business from anywhere in the world. Software version 2.1 RINS1840-2

EURO 46 APP. User Manual. Connect to your home or business from anywhere in the world. Software version 2.1 RINS1840-2 EURO 46 APP User Manual Connect to your home or business from anywhere in the world. Software version 2.1 RINS1840-2 Contents Two Way Wireless High Security 3 User Friendly Keyfobs 4 User Automation Outputs

More information

Sevenoaks Smart Homes Safety and Security Guide

Sevenoaks Smart Homes Safety and Security Guide Sevenoaks Smart Homes Safety and Security Guide 01732 617 170 Contents Safety and security overview 2 Using the Security menu 3 Accessing the Security menu 3 Arming your system 3 Disarming your system

More information

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ READY ARMED READY 1 OFF 7 INSTANT 2 AWAY 8 CODE 6BYPASS 9 CHIME 9,67$%3 9,67$%3 &RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ 8VHU*XLGH ARMED READY 1 OFF 2 AWAY 3 STAY 4 MAX 5 TEST 6 BYPASS

More information

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface INSTRUCTION MANUAL FI6000 Fire Alarm Interface Thank you for choosing another quality product from Amperes Electronics. FI6000 is a phase evacuation controller which can be integrated with various Amperes

More information

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

IDS S E C U R I T Y IDS816.  User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00 INHEP DIGITAL IDS S E C U R I T Y IDS816 User Manual MANUAL NO. 700-283-02A ISSUED November 2004 VERSION 1.00 Contents 1. Introduction to the IDS816... 4 2. Understanding the Keypad Indicators... 4 3.

More information

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ 9,67$)% &RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ 8VHU*XLGH FIRE FIRE * PULL K3522 3/99 TABLE OF CONTENTS SYSTEM OVERVIEW...4 General...4 A Partitioned System...4 Zones...5 Fire

More information

WiFi GSM APP Smart Home Security System

WiFi GSM APP Smart Home Security System User Manual WiFi GSM APP Smart Home Security System Tips: Please read through this user manual before installation so as to operate properly. Please keep well of the user manual for further reference.

More information

Building Technologies

Building Technologies Building Technologies The safe, sure way to more efficient evacuation: the E100 voice alarm system from Siemens. The safe, sure way to an evacuation system that gets people moving: the E100 from Siemens.

More information

Simplify. Secure. Your Home. Your Life. M1 Security & Automation Controls

Simplify. Secure. Your Home. Your Life. M1 Security & Automation Controls Secure Your Home Simplify Your Life M1 Security & Automation Controls Protection and Peace of Mind Your home should be a place where you and your family feel safe and comfortable. Elk s M1 systems are

More information

Hi, welcome to the topic on Fire Detection and Alarm Systems. This topic forms one of the critical knowledge areas for prospective fire safety

Hi, welcome to the topic on Fire Detection and Alarm Systems. This topic forms one of the critical knowledge areas for prospective fire safety Hi, welcome to the topic on Fire Detection and Alarm Systems. This topic forms one of the critical knowledge areas for prospective fire safety manager. As the appointed fire safety manager for a premise,

More information

Table of Contents About This User s Guide... 2 Introduction... 2 Security System Basics... 3 What is a Point?... 3 What is a Faulted Point?...

Table of Contents About This User s Guide... 2 Introduction... 2 Security System Basics... 3 What is a Point?... 3 What is a Faulted Point?... Table of Contents About This User s Guide... 2 Introduction... 2 Security System Basics... 3 What is a Point?... 3 What is a Faulted Point?... 3 Are All Points the Same?... 3 Controlled Points... 4 24-Hour

More information

PERSONS NEEDING ASSISTANCE who are unable to quickly walk down the exit stairwells should follow these alternative procedures:

PERSONS NEEDING ASSISTANCE who are unable to quickly walk down the exit stairwells should follow these alternative procedures: LANSDOWNE WOODS EMERGENCY ACTION PLAN FOR RIVERBEND AT LEISURE WORLD (passed November 30, 2011) INTRODUCTION The information contained in this section is for the use of all Riverbend residents in the event

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd THE NANO SYSTEM The revolutionary analogue addressable control panel Nano, the revolutionary control panel from Gent Nano is the latest fire detection control panel from Gent by Honeywell. It s a single

More information

Operation Manual - PC-ARF - P IMPORTANT:

Operation Manual - PC-ARF - P IMPORTANT: Operation Manual - PC-ARF - MODE SPEED LOUV. TEMP HIGH LOUV.? IMPORTANT: READ AND UNDERSTAND THIS MANUAL BEFORE USING THIS WIRED REMOTE CONTROL SWITCH. KEEP THIS MANUAL FOR FUTURE REFERENCE. P5414986 TC-12001

More information

Contents. Glossary

Contents. Glossary Contents Glossary ------------------------------------------------------------------------------------------------------ 6 1. Introduction to the IDS 1632 -------------------------------------------------------------

More information

SUSTAINED SAFETY DURABLE QUALITY

SUSTAINED SAFETY DURABLE QUALITY SUSTAINED SAFETY DURABLE QUALITY SINCE 2003 asian lifts OUR PRESTIGIOUS 15 Years of Reputation EMI Option for Trust ISO 9001:2008 Certified 5 Year Warranty 100% Customized SMS Notification Alert GST Benefits

More information

VISTA-128BP/VISTA-250BP/ VISTA-128SIA Enhanced Commercial Burglary Partitioned Security System With Scheduling User Guide K5895V5 4/09 Rev C

VISTA-128BP/VISTA-250BP/ VISTA-128SIA Enhanced Commercial Burglary Partitioned Security System With Scheduling User Guide K5895V5 4/09 Rev C VISTA-128BP/VISTA-250BP/ VISTA-128SIA Enhanced Commercial Burglary Partitioned Security System With Scheduling User Guide K5895V5 4/09 Rev C Your Honeywell security system is designed for use with devices

More information

DISASTER MANAGEMENT PLAN 3.0 IDENTIFICATION OF MAJOR HAZARD POTENTIAL

DISASTER MANAGEMENT PLAN 3.0 IDENTIFICATION OF MAJOR HAZARD POTENTIAL DISASTER MANAGEMENT PLAN 1.0 DISASTER (EMERGENCY) A disaster or an emergency, occurring in a project is one, as a result of a malfunctioning of the normal operating procedures or an intervention of an

More information

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock. Preface Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock. The GSM Security Alarm ( The Alarm ) adopts the most advanced

More information

Schindler HXpress An efficient, affordable modernization for hydraulic elevators

Schindler HXpress An efficient, affordable modernization for hydraulic elevators Schindler HXpress An efficient, affordable modernization for hydraulic elevators Schindler Modernization The Schindler HXpress modernization restarts the clock on your elevator s service life. Improved

More information

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat. IT801 Thermostat User s Manual The complete guide to the set up and operation of your new smart Wi-Fi thermostat. The smart Wi-Fi thermostat system learns your comfort preferences, then finds opportunities

More information

C106 Coded Access Keypad

C106 Coded Access Keypad C106 Coded Access Keypad Including: CS106 and BL106 Door Entry & Coded Entry PD-024 Issue 4 Features Up to 10 codes each of 1 to 8 digits. Two Time Zones for Staff / Executive operation. Output for Fail-Safe

More information

User s Manual and Warranty Information ThyssenKrupp Access

User s Manual and Warranty Information ThyssenKrupp Access User s Manual and Warranty Information ThyssenKrupp Access Welcome to your Destiny ThyssenKrupp Access would like to thank you for choosing the Destiny. You have purchased one of the finest residential

More information

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00 INHEP DIGITAL IDS S E C U R I T Y IDS816 User Manual MANUAL NO. 700-283-01C ISSUED APRIL 2005 VERSION 2.00 Contents 1. Introduction to the IDS816... 4 2. Understanding the Keypad Indicators... 4 3. Programmable

More information

Vancouver Convention Centre Safety and Security Guide AME Roundup 2018 January 22-25, 2018

Vancouver Convention Centre Safety and Security Guide AME Roundup 2018 January 22-25, 2018 Vancouver Convention Centre Safety and Security Guide AME Roundup 2018 January 22-25, 2018 In partnership with our valued clients and suppliers, the Vancouver Convention Centre strives to create a safe

More information

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0 User s Guide SUB-MA7240O-0001.OG.Solution40-111.doc Created: 6/05/03 Last Updated: 23/09/03 MA7240AO-0001 Version 1.0 2 Table Of Contents User List...6 Quick Reference..7 Features...7 Keypad User's Guide...8

More information

VISTA-50P VISTA-50PUL

VISTA-50P VISTA-50PUL Security System User's Manual VISTA-50P VISTA-50PUL N5943-6V1 Rev B 4/99 TABLE OF CONTENTS SYSTEM OVERVIEW...4 General...4 A Partitioned System...4 Zones...4 Fire Protection...5 Burglary Protection...5

More information

The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70

The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70 The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70 1. Identify the Equipment and carry out a Risk Assessment before installation AD1000EN- 1R Main Unit EN1 Speaker

More information

Flexible home automation

Flexible home automation GE Energy Industrial Solutions HabiTEQ TM Flexible home automation for energy efficiency, safety and comfort GE imagination at work In the rhythm of your family Convenience at your fingertips 3 Leaving

More information

VOLUSIA COUNTY FIRE CHIEFS ASSOCIATION MODEL OPERATING GUIDELINE

VOLUSIA COUNTY FIRE CHIEFS ASSOCIATION MODEL OPERATING GUIDELINE VOLUSIA COUNTY FIRE CHIEFS ASSOCIATION MODEL OPERATING GUIDELINE GUIDE # SUBJECT: Elevator Operations and Emergencies DATE ISSUED: 5/28/2014 UPDATED: I. PURPOSE: The purpose of this guideline is to provide

More information

PNEUMATIC VACUUM ELEVATORS LLC USER MANUAL

PNEUMATIC VACUUM ELEVATORS LLC USER MANUAL PNEUMATIC VACUUM ELEVATORS LLC USER MANUAL 14804 S.W. 136 th Street, Miami, FL. 33196 Phone: 305-235-6707 Fax: 305-235-6765 Email: info@vacuumelevators.com www.vacuumelevators.com 1 IMPORTANT SAFEGUARDS

More information

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using. V1.0 Smart Home Alarm System User Manual APP download via QR Code scanning Please read the manual carefully before using. Content FUNCTION PROFILE 2 THE SCHEMATIC GRAPH OF HOST 3 PROCESS OF BOOTING 6 OPERATION

More information

IDS816 User Manual H Issued January 2009

IDS816 User Manual H Issued January 2009 1 Contents Glossary-------------------------------------------------------------------------------------------------------------------6 1. Introduction to the IDS 816---------------------------------------------------------------------------7

More information

ADVISOR CD User Manual. Software from version: V

ADVISOR CD User Manual. Software from version: V ADVISOR CD 3403 User Manual Software from version: V6.0 142715999-1 COPYRIGHT SLC BV 1996. All rights reserved. No part of this publication may be reproduced, transmitted, stored in a retrieval system,

More information

LYNX Touch L5210 Series Security System

LYNX Touch L5210 Series Security System LYNX Touch L5210 Series Security System User Guide 800-19975 12/14 Rev. B LYNX Touch L5210 Series Your Honeywell security system is designed for use with devices manufactured or approved by Honeywell for

More information

l 02-April-2010 For INSTANT CARE

l 02-April-2010 For INSTANT CARE l 02-April-2010 For INSTANT CARE Table of Contents 1. Application Overview 1 1.1. Identifying The Parts 1 1.2. The Power Supply 3 1.3. Line Capture 3 1.4. Line Failure Detection 4 1.5. How to install the

More information

AXI LED USER MANUAL (REV. 1.0)

AXI LED USER MANUAL (REV. 1.0) Security & Home Automation System AXI LED USER MANUAL (REV. 1.0) CONTENTS PREFACE FEATURES LED KEYPAD OUTLOOK 1.0 LIGHT INDICATION 1 2 4 6 CHAPTER 1: ALARM SYSTEM CONTROL 1.0 USING LED KEYPAD 1.0.1 ARMING

More information

DS7446KP. User Guide. Keypad

DS7446KP. User Guide. Keypad DS7446KP EN User Guide Keypad DS7446KP User Guide Command Quick Reference Command Quick Reference Command Type Basic Arming Commands Advanced Arming Commands System Disarming Commands Command Turn the

More information

ELEVATORS. Integration of Codes between Fire Alarm, Sprinklers, and Elevators 12/5/2017

ELEVATORS. Integration of Codes between Fire Alarm, Sprinklers, and Elevators 12/5/2017 12/5/2017 1 ELEVATORS Integration of Codes between Fire Alarm, Sprinklers, and Elevators Encore Electric Inc. Prepared By John McGovern and Jeffrey Engelstad 12/5/2017 Encore Electric Inc. 2 Agenda Basics

More information

CONTENTS. (User s Manual)

CONTENTS. (User s Manual) CONTENTS (User s Manual) 1. Foreword & Main Features & Brief introduction of the Product 2. Understanding of Alarm Host 3. Specifications 4. Type and definition of Defense Line 5. Programming the alarm

More information

DESCRIPTION OF KEYPAD (Access module with segments)

DESCRIPTION OF KEYPAD (Access module with segments) DESCRIPTION OF KEYPAD (Access module with segments) For the most convenient control and status indication the JABLOTRON 100 system offers various types of access modules. Controlling (setting, unsetting

More information

A Beginners Guide to Inner Range Systems

A Beginners Guide to Inner Range Systems A Beginners Guide to Inner Range Systems Inner Range manufactures a range of integrated Intrusion Detection and Access Control systems to cover sites of any size, while sharing a common configuration layout.

More information

University of Toronto Section Technical Design Standards for Division 14 February 2015 DIVISION 14 - ELEVATOR DESIGN STANDARDS

University of Toronto Section Technical Design Standards for Division 14 February 2015 DIVISION 14 - ELEVATOR DESIGN STANDARDS DIVISION 14 - ELEVATOR DESIGN STANDARDS 1 General 1.1 General Requirements 1.2 References 1.3 Submittals, Samples, Shop Drawings and Manuals 1.4 Warranty Provisions 1.5 Maintenance Provisions 1.6 Appendix

More information

Austin Independent School District Police Department Policy and Procedure Manual

Austin Independent School District Police Department Policy and Procedure Manual Policy 8.07 Austin Independent School District Police Department Policy and Procedure Manual Life Safety Systems I. POLICY The proper operations of the AISD Life Safety Systems (LSS) are essential for

More information

Ultrasonic Parking Guidance System Program

Ultrasonic Parking Guidance System Program 1 Ultrasonic Parking Guidance System Program Introductions: The parking Guidance Information System (PGIS) based on the computer and MCU as the core of the intelligent parking lot parking guidance system.

More information

PROJECTS Ph: ,

PROJECTS Ph: , 1. RFID BASED OFFICE ATTENDANCE SYSTEM USING MICROCONTROLLER 2. BUS STOP AUTOMATION USING RFID 3. RFID BASED LIBRARY MANAGEMENT SYSTEM 4. CELL PHONE BASED VOTING MACHINE 5. POWER THEFT MONITORING SYSTEM

More information

AE300. Integrated Voice Alarm System

AE300. Integrated Voice Alarm System AE300 Integrated Voice Alarm System AE300 Integrated Voice Alarm System The AE300 is the all-in-one solution for demanding emergency sound applications and voice evacuation systems that require operational

More information