TST Portable Event Logger &Programmer for UML-51 Controllers v15.6

Size: px
Start display at page:

Download "TST Portable Event Logger &Programmer for UML-51 Controllers v15.6"

Transcription

1 P.O.B 1180, Kfar saba 44111, israel Plant: 3 Hayozma St. Kfar saba, Israel Tel: Fax: E.mail :lsales@leeav.co.il TST Portable Event Logger &Programmer for UML-51 Controllers v15.6 Introduction The TST-1 is a portable event logger and programmer which provides both detailed status reports and programming of the elevator functions via its two main modes which are the display mode and the programming mode. The tool is the same with additional software for UML-51 systems. Connection:Important! You must disconnect power from the controller before connecting it to the TST. Connect the TST to the D-Type 15 pin connector on the UML card. On the screen will appear 2 modes: A=UML31 press A for UML-21/31/41 B=UML51 press B for UML-51. The Display Mode=A The display mode presents a complete and updated record of the last thirty Failures and Events, and the current status of inputs and outputs as the microprocessor identifies them. The display mode may be used while the elevator is in motion without affecting the operation of the elevator. The display mode is a basic mode, which is accessed without the use of a code. 1. Last ten Failures For each of the last 10 failures the following details appear on the screen: The name of the failure. The floor on which the failure occurred (indicated on right hand side of screen). The input relevant to the failure. The segment relevant to the failure (the floor indicator on the UML card also functions as a failure indicator, the relevant segment blinking to indicate type of failure). The last thirty events are presented in the same format as the last ten failures. 2. Last ten Events For each of the last 10 Events the following details appear on the screen: The name of the Event, the floor on which the Event occurred (indicated on right hand side of screen). The input relevant to the Event The segment relevant to the Event (the floor indicator on the UML card also functions as a failure indicator, the relevant segment blinking to indicate type of failure). The last thirty events are presented in the same format as the last ten failures. -1-

2 3. Inputs All available inputs from In-1 to In-16 are displayed. 4. Outputs All available outputs from Out-1 to Out-16 are displayed. 5. Cabin Calls Mode Entry to the cabin calls mode (via the display mode) enables cabin calls to be made directly via the TST. TST-1 Possible Failures Name of Failure (as it Digital Meaning of the failure appears on TST-1 screen) Segments on the Elv Interlock Bridged a/1 After Passing From Inspection to normal mode the firmware checking if the interlocks are open, if they bridged or didn t opened this failure will indicate. Obstruction b/1 Obstruction timer. Indicates an Emergency stop due to the absence of inductor signal for a period of time equal to the set value of this timer. This is the Travelling timer Interlocks c/1 Hall Door Interlock contact. Indicates failure of positive door close, after two unsuccesful closing try. Car Fire Switch d/1 Improper car fire-key removal. Registered in the Fire-Control mode when the fire-key in the car is removed at any floor other than the lobby. The car will not travel until the key is restored. Contact Fall e/1 An open circuit was detected in the RC input chain. The Main Contactors failed to open, or a thermistor /thermo contact was tripped. Open Limit Switch f/1 Open Door limit switch not activated. Hall Push Button g/1 Stuck hall push-button Failure-Firmware ignores hall-calls from the landing at which the button registered as stuck. Safety Circuit dp/1 Safety Circuit open. An open safety contact to input C19 trips this fault. Pressing of the Emergency Stop button in the car is also registered as an open safety contact fault. I2 Inductor a/2 Down-Count Inductor. This fault is activated when the microprocessor fails to receive the expected pulse from this inductor. Photo Eye b/2 Photocell Blocked. Indicates photocell malfunction, or person/object blocking the photo-eye for more than the set value of the relevant timer. Doors remain open unless the Nudging function is active.if the Nudging function has been activated, this will not be logged as a fault. Instead, the Nudging action -2-

3 logged as a fault. Instead, the Nudging action will be logged as an event. Gen.Terminat c/2 Emergency Generator. For lifts in group control mode only. This fault indicates the lift has been taken out of service due to the activation of emergency generator mode. In this mode, all lifts are idled except one. The idled lifts will indicate this fault. Also, check Group Control connections between lifts on GN line. 60s Timer d/2 The car fails to start moving after trying for sixty seconds. This could be caused by an open door, interlock failure or other reasons. Slow Speed Timer e/2 Indicates that slow speed operation has been detected for an unacceptably long time. Measured from start of slow speed to full stop at landing. This failure results in Emergency Stop. The acceptable time interval is not user adjustable, and is determined by the type of elevator and the UML controller Board being used, as per the following table: -AC2-speed timer duration:15 sec -I3-DA(ACVV, VVVF) Timer dration: 6 sec -Hydraulic Timer duration=10sec I3 Inductor f/2 The inductor fails to signal within 3sec of the car having left, travelled from the door zone. Out Of Door Zone g/2 Indicates that an opening of doors was attempted while the lift was not in the door zone. Group Communication dp/2 In Group Control, Failure of this car to respond together with its group. TST-1 Possible Events Name of Failure (as it appears on TST-1 screen) Power On Inspection Control Hall Fireman Mode Car Fireman Mode Over Load Signal/Buzzer Full Load Bypass Door Safety Edge Door Open Push Button Meaning of the Event Registers a power up of the controller board. Usually follows a power failure. The event will also be registered with a system reset caused by electrical noise or software problem. The origin of such problems is typically an external source such as static electricity or spurious inductances. Inspection Control mode was activated. Hall Fireman mode was activated. Car Fireman mode was activated. An overloaded car condition was detected. The full-load or bypass switch was activated. When bypass is active hall calls are ignored. The door safety Edge was activated by an obstruction.event indicated after the obstruction persists for 30sec. The door open push-button,in the car,was pressed.event indicated after button pressed consistently for 30sec. -3-

4 Emergency Generator Attendant Service Out of Service Down Peak Up Peak Two Way Peak Loading Control Photo Eye Nudge Buzzer Separation From Group Bell Alarm Hall Sanitar Car Sanitar Independent Service indicated after button pressed consistently for 30sec. The emergency generator was activated due to a power failure. Attendant Service mode was activated. The car was taken out of service by manually operating the appropriate key switch. Peak passenger traffic, in the Down direction only, was detected. Peak passenger traffic, in the Up direction only, was detected. Peak passenger traffic, in both the Up and Down directions,was detected. The Loading service mode was activated. While the Nudging function was active, the buzzer sounded, indicating that some person or object obstructed the photoeye for more than 30sec. The function which separates the action of this car from the group, in group control, was initiated. The Emergency Alarm button in the car was pressed. Key operation of the car was initiated from a landing (Frequently used in hospitals for express calls) Key operation of the car was initiated from inside the car.(frequently used in hospitals for express calls) Independent service mode was activated. The Programming Mode= B The programming mode is accessed only through the use of your own private code. This security feature is necessary because the programming mode enables changes to be made to timers, parameters and the status of the lift. Important Note: all cards are provided with the factory code These four digits are replaced by the digits of your own personal code during one of the stages of the programming mode. It is recommended to Connect the Tst Without power to the master card and operate the programming mode only when the elevator is out of operation. Using the programming mode while the elevator is in motion, will trigger the emergency stop. TST-1 Programming Subjects For UML-51 Item Description Explanation DS Drive System To Define The Drive System CS Control System To Define The Control System T Timers Timers Setting S Status Status Setting P Parameters Parameters Setting FC Floors Chars All Floor indicators Setting -4-

5 G Group Group Setting H Homing Homing Setting SL Sleep Cancel lift setting NB Nudging /Busy Nudging Or Busy Signal CF Cancel Floors Cancel Car/Hall Calls SP Service Period Canceling The Lift After Period J Job Number Job Number For Monitoring System N New Password Replace a new password SF Short Floors Short distance between 2 floors, less than 50 cm. TST-1 Programming Details List Of Drive System For UML-51 Item Description Explanation DS Drive System To Define The Drive System AC-2 Speed=1 AC-2 Speed Drive System For Vvvf Open Loop Please define the U/D Timer for 1 Sec. Vvvf =2 Variable Voltage Variable Frequency Drive System This Mode is for Vvvf Close Loop Only. Hyd =3 Hydraulic Drive System For Beringer / Gmv and Star Delta Beringer/Blain/Beker =1 Gmv/Omar=2 Star/Delta=A Direct start=b Remark: For Changing the Drive System Power on Required. TST-1 Programming Details List Of Control System For UML-51 Item Description Explanation CS Control System To Define The Control System A.P.B= 1 F5-Call=2 Full-Call=3 Automatic Push Button System, In this Drive mode all the Hall Calls Connecting to the Down Calls inputs, Only One Hall Call Will Accepted. The Wiring for this system is as Down Collective wiring. One Car Call is accepted, you can program Collective system for the Car Calls. 5 Floors Full Collective Economic System only With the Master Card Please refer the Electrical Drawings. Regular Full Collective Please refer the Electrical Drawings. -5-

6 TST-1 Programming Details List Of Timers For UML-51 T2 Obstruction Timer 10-99sec Traveling Timer. When A=LRN mode The obstruction Timer is not functioning, a new power resetting the LRN mode. T3 Door Close Timer 05-30sec Maximum time for closing T4 Door Open Timer 05-30sec Maximum time for opening T5 Floor Delay 2-9sec Floor Delay Timer since OLS opened. T6 Door Close At Parking 10-30sec After the Car is Free. TST-1 Programming Details List Of Statuses For UML-51 S1 Door Position At Lobby Floor A=Close B=Open S4 Re Close Door Timer A=Long B=Short S5 Lanterns Activate A=Yes B=No S9 Generator Type A=Gn1 B=Gn2 All the Other floors adjustable by SW-1/2 dip-switch. If Long The photo eye will not cut the floor delay timer. To define lanterns instead of directional arrows for the SSD hall digital displays. Gn1= One lift will be left in operation during diesel generator regimen in a group. Gn2= Two lifts will be left in operation during diesel generator regimen in a group. S11 Hall Cancel Activate A=yes S13 Zone Travel Activation A=yes S14 Up Hall Calls Delay A=yes The default is no, if B means canceling all hall calls. All hall calls will be ignored. If no, the lift will stay on the last floor, unless homing function sated up. This function adding 1 sec of delay to the up hall calls when pressing both direction in ones. -6-

7 S15 Hall Lamps Blinking A=yes The default for simplex is A. The registered hall calls will blink during traveling. S16 Peak Down Active A=yes This regimen recognizing automatically, if heavy traffic demand to the lobby floor. The highest floors will get the highest priority to all the lifts on the same group. S17 Peak Up Active A=yes This regimen recognizing automatically if heavy traffic demand from the lobby floor. The lobby floor will get the highest priority to all the lifts on the same group. S18 Peak Two Ways Active Not available in this version. S20 Up/Down Calls Canceling. For all car and hall calls This function canceling any call without taking the wires from the controller. TST-1 Programming Details List Of Parameters For UML-51 P1 Hall Firefighter main floor Key. 0-7 Floor P2 Lobby Floor 0-7 Floor P3 Maximum Car Calls Canceling For all car calls only. Sets the floor designated as the main floor (Lobby where hall key must be inserted), in fire control mode. Any of the 0-7 floor numbers in the range shown on the screen may be entered. Designates the selected floor as the Lobby for functions that require such a designation parking in Group The default is 1 for all floors, means no limits for car calls, if the maximum of car calls will be less then the number of stops, all car calls will be canceled after registering more then the maximum number. TST-1 Programming Details-List Of Floors Chars For UML-51 FC Floors Chars Programming All Signs of all Digital Displays If By Lobby=All The Digital Displays Will get the default signs according lobby location. If By Floor=Manual Programming. -7-

8 TST-1 Programming Details-List Of Group Type & Group Number For UML-51 G Group Type 1-7 Lifts How many Lifts communicating on the same Group Control, press 2 for duplex,3 for triplex and so on. Group Number 1-99 Number Of Lifts For Monitoring System TST-1 Programming Details-List Of Floors Chars For UML-51 H Homing Active A=Yes B=No Homing Floor 0-7 Floors Homing Time 0,8-20 Minutes To Make Active Press A Floor Location. Time to travel to the Homing Floor After the Car is Free. TST-1 Programming Details-List Of Lift Canceling For UML-51 SL Sleep/ Cancel Lift A=Hall 0-7 Floor Two Modes For Lift Canceling When Hall Lift Canceling, you have to locate the floor for canceling. In this Mode the doors will be closed and all the digital displays will be shut down. B=Car In any floor This Mode will Stop the Car in the nearest Floor, The doors will open and all the digital displays will shut down. TST-1 Programming Details-List Of Lift Nudging/Busy For UML-51 NB Nudging/Busy The Default is Busy. The registered calls are blinking during traveling and lighting continuously when occupied. If Nudging First Only nudging buzzer without closing the door after option Second option nudging timer 30-60sec, The same as the first option but with closing door. -8-

9 TST-1 Programming Details-List Of Lift Cancel Floors For UML-51 CF Cancel Floors Car Any Car call can be cancel Down Any Down call can be cancel Calls Up Calls Any Up call can be cancel TST-1 Programming Details-List Of Lift Service Period For UML-51 SP Service Period Days A=Yes B=No This function preventing the lift to operate after the period. The default is no, When yes press the period days. TST-1 Programming Details-List Of Job Number For UML-51 J Job Number 4 digits For the monitoring and pc tst recognition TST-1 Programming Details-List Of New Password For UML-51 N New Password 4 digits For changing the factory code to a new code number The factory code is 0000 TST-1 Programming Details-List Of Short Floors For UML-51 SF Short Floors All floors Possible to regulate short distance traveling, in this mode the start traveling speed will be low speed between that floors. The slow down will be done on the previous floor. TST-1 Programming Details-List Of Set to Default For UML-51 Set to default Set to default A=yes When yes all the programmed values will set to default, after this power on is required. -9-

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION. INSTALLATION INSTRUCTIONS FOR SYMCOM S CONTROL MODEL PC-05 BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.!

More information

Since giving rise to the elevator industry more than 150 years ago, Otis has been at the forefront of elevator technology.

Since giving rise to the elevator industry more than 150 years ago, Otis has been at the forefront of elevator technology. OTIS SKY Since giving rise to the elevator industry more than 150 years ago, Otis has been at the forefront of elevator technology. Through the years, Otis team of professional engineers and designers

More information

Small in size, with grand features USER GUIDE Elle-même petite, mais avec caractéristique grand

Small in size, with grand features USER GUIDE Elle-même petite, mais avec caractéristique grand 1 Small in size, with grand features USER GUIDE Elle-même petite, mais avec caractéristique grand 2 PARAMETER LIST 00 Elevator Type 01 Command Type 02 Door Type 03 Automatic Door at Floor 04 Automatic

More information

Operation Manual. Programmable Logic Controller

Operation Manual. Programmable Logic Controller Operation Manual Programmable Logic Controller Part No. 9983-0000-E01 / January 2018 OPERATION MANUAL TABLE OF CONTENTS CUSTOMER SERVICE 3 CONTACT INFORMATION 3 ORDER INFORMATION 3 INTRODUCTION 4 THE PROCESS

More information

Electronic Pellet Burner Controller NPBC-V3-1

Electronic Pellet Burner Controller NPBC-V3-1 Electronic Pellet Burner Controller NPBC-V3- SOFTWARE VERSION 3.2/3. page of 3 CHANGES IN THE TECHNICAL AND USER GUIDE OR IN THE SOFTWARE VERSION Technical and User Guide's version Changes Page 2.8. The

More information

The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70

The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70 The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70 1. Identify the Equipment and carry out a Risk Assessment before installation AD1000EN- 1R Main Unit EN1 Speaker

More information

User Guide ems25plus. Page 1. Normal operation. Product interface

User Guide ems25plus. Page 1. Normal operation. Product interface Page 1 Product interface rmal operation During normal operation, EMS controllers display the information below. Assuming the product temperature is correct when the outlet is open, this means that the

More information

2000 Series. Program Entry Guide. Control Panels

2000 Series. Program Entry Guide. Control Panels 2000 Series EN Program Entry Guide Control Panels 2000 Series Program Entry Guide About This Manual EN 2 About This Manual This guide describes the programming parameters available to the 2000 Series Control

More information

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0 User s Guide SUB-MA7240O-0001.OG.Solution40-111.doc Created: 6/05/03 Last Updated: 23/09/03 MA7240AO-0001 Version 1.0 2 Table Of Contents User List...6 Quick Reference..7 Features...7 Keypad User's Guide...8

More information

CSP-204 CSP-208 CSP-104 CSP-108

CSP-204 CSP-208 CSP-104 CSP-108 Fire Alarm Control Panel CSP-204 CSP-208 CSP-104 CSP-108 Operation manual Firmware version 1.1 csp-x_o_en 06/15 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND tel. 58 320 94 00 www.satel.eu CONTENTS

More information

ELEVATOR UPGRADE AND MODERNIZATION

ELEVATOR UPGRADE AND MODERNIZATION BOYLE COUNTY COURTHOUSE ELEVATOR UPGRADE AND MODERNIZATION SPECIFICATIONS 1-1-2017 1 ON Provide labor and material to furnish and install the following: SECTION I. SYSTEM OPERATING FEATURES DUTY The present

More information

Dryer Controller M720

Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,

More information

Pump Logic User Manual CB-1000 P/N ILK-CB1000-1

Pump Logic User Manual CB-1000 P/N ILK-CB1000-1 Pump Logic User Manual CB-1000 P/N ILK-CB1000-1 STATEMENT OF LIMITED WARRANTY The limited warranty applicable to this product is set forth in USFilter Control Systems standard terms of sale that are made

More information

AXI LED USER MANUAL (REV. 1.0)

AXI LED USER MANUAL (REV. 1.0) Security & Home Automation System AXI LED USER MANUAL (REV. 1.0) CONTENTS PREFACE FEATURES LED KEYPAD OUTLOOK 1.0 LIGHT INDICATION 1 2 4 6 CHAPTER 1: ALARM SYSTEM CONTROL 1.0 USING LED KEYPAD 1.0.1 ARMING

More information

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4 Programming Guide We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure. Notice The material and instructions covered in this manual have been carefully checked for accuracy and are presumed to be reliable. However, Radionics, Inc. assumes no responsibility for inaccuracies

More information

Installation, Start-Up, and Operating Instructions

Installation, Start-Up, and Operating Instructions Installation, Start-Up, and Operating Instructions CONTENTS Page SAFETY CONSIDERATIONS...1 GENERAL...1 INSTALLATION...1-5 Install Batteries...1 Select Transmitter Location (Optional)...1 Mount Transmitter

More information

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION Environment IMPORTANT INFORMATION It is not anticipated that this equipment will be exposed to adverse environmental conditions without additional protection. Site the equipment in a frost free area. Ensure

More information

BURGLAR ALARM PANEL BS-468

BURGLAR ALARM PANEL BS-468 BURGLAR ALARM PANEL BS-468 Contents 1. Description... 3 2. Instructions for the user... 4 2.1Basic operations... 4 Complete system.... 4 Split system.... 4 2.2 Armed system indication... 5 2.3 Advanced

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

Applications and Examples

Applications and Examples Applications and Examples Comat AG Bernstrasse 4 CH-3076 Worb Tel. +41 (0)31 838 55 77 www.comat.ch info@comat.ch Fax +41 (0)31 838 55 99 Contents General remarks to the examples... 3 Applications, Examples

More information

Static Pressure Control

Static Pressure Control The (model SPC-2) is a fully programmable controller that provides extensive flexibility for your curtain or awning control needs. The SPC-2 automatically controls the pressure in a room by operating a

More information

Installation of a new engineered HYDRAULIC elevator complete as described in this standard.

Installation of a new engineered HYDRAULIC elevator complete as described in this standard. DIVISION 14 - CONVEYING SYSTEMS Section 14240 - Hydraulic Elevators WORK INCLUDED Installation of a new engineered HYDRAULIC elevator complete as described in this standard. SUBMITTAL'S Submit bound operation

More information

User Manual. Dryer Controller M720

User Manual. Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009

More information

Independent Zone Control (I.Z.C.)

Independent Zone Control (I.Z.C.) Operation and Installation Guide Independent Zone Control (I.Z.C.) DELAYED INSTANT ARMED 1 2 3 4 7 5 6 8 9 * * fi Radionics R D279A Operation & Installation Guide 46456B Page 2 Copyright 2000 Radionics

More information

HOSHIZAKI AMERICA, INC. SERVICE BULLETIN

HOSHIZAKI AMERICA, INC. SERVICE BULLETIN HOSHIZAKI AMERICA, INC. SERVICE BULLETIN Subject: E SERIES CONTROL BOARD Page 1 of 4 Beginning in February, the KM Universal Alpine replacement control board part number 2U0139-01, will sub to a new Control

More information

Memcom Emergency Telephone

Memcom Emergency Telephone Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming

More information

D1255RB/D1256RB/D1257RB

D1255RB/D1256RB/D1257RB D1255RB/D1256RB/D1257RB EN Installation Instructions Fire Keypads and Fire Alarm Annunciator D1255RB/D1256RB/D1257RB Installation Instructions Listings and Approvals Listings and Approvals UL 365 UL 609

More information

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual Syncro AS Analogue Addressable Fire Control Panel User Manual Man-1100 Issue 02 Nov. 2008 Index Section Page 1. Introduction...3 2. Safety...3 3. Panel Controls...4 3.1 Access Level 1...4 3.2 Access Level

More information

JA-63 Profi User manual

JA-63 Profi User manual JA-63 Profi User manual Contents: 1 Limited warranty... 2 2 Indicators... 3 3 Controlling the system... 4 3.1 Arming... 5 3.2 Disarming... 6 3.3 Panic Alarm... 6 3.4 To stop ALARM... 6 3.5 Home arming...

More information

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL THE EVOLUTION OF CONTROL APP & CLOUD PORTAL APP MAIN APP FUNCTIONS EMERGENCY Facilitates the work of installers and company maintenance operators. Allows control of the functions of all lights of the system.

More information

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector) SMAC Controller Industrial Lubrication Systems Operation The SMAC Controller is a multi-purpose programmable controller used with industrial lubrication systems. Controller settings are saved whenever

More information

SIGMA MRL E1000.

SIGMA MRL E1000. SIGMA MRL E www.sigmaelevator.com Lifting up Trust Our dedication and passion to reach customer satisfaction always have been a driving force of our creative and innovative ideas. As your elevator partner,

More information

CA60Plus. Installation manual

CA60Plus. Installation manual CA60Plus Installation manual WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire

More information

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above Surveyor Excel Fire Alarm Control Equipment Network version Programming Manual VERSION 14.0 and Above MASTER MANUAL Drawing S1606. PCB Layout guide for XLK range of control panels FCPXLK-2/4/6/8 & FCPXLK2/4/6/8TW

More information

The Information Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will

The Information Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will The formation Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will be working on the Blodgett XR8 Oven. All other uses are

More information

Installation Manual GalaXy G2 / G3 / GD. o Settings GalaXy o Linking with iprotect o Keymap

Installation Manual GalaXy G2 / G3 / GD. o Settings GalaXy o Linking with iprotect o Keymap Installation Manual GalaXy G2 / G3 / GD o Settings GalaXy o Linking with iprotect o Keymap Publication July 2013, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com

More information

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11 Table of Contents 1. OVERVIEW... 3 2. SYSTEM LAYOUT... 4 3. SPECIFICATIONS... 8 3.1 SYSTEM COMPONENTS...9 3.2 PLC INPUTS AND OUTPUTS...9 3.3 FUNCTION KEYS...10 3.4 DEFAULT SET POINTS AND TIMERS...10 4.

More information

Digiplex LED Keypads User s Manual

Digiplex LED Keypads User s Manual KLEDEU03.fm Page -1 Friday, May 4, 2001 11:25 AM Digiplex LED Keypads User s Manual KLEDEU03.fm Page 0 Friday, May 4, 2001 11:25 AM KLEDEU03.fm Page 1 Friday, May 4, 2001 11:25 AM TABLE OF CONTENTS 1.0

More information

Security System. User Guide for the LED Command Center

Security System. User Guide for the LED Command Center Security System User Guide for the LED Command Center National Security Systems Inc (800)457-1999 MY SECURITY COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY

More information

Matrix2000 MEMBER OF BSIA. Installation and Operation Manual. Conventional Fire Alarm Panels 4-24 Zones. British Security Industry Association

Matrix2000 MEMBER OF BSIA. Installation and Operation Manual. Conventional Fire Alarm Panels 4-24 Zones. British Security Industry Association Matrix2000 Installation and Operation Manual Conventional Fire Alarm Panels 4-24 Zones ISO 9002 MEMBER OF BSIA British Security Industry Association CONTENTS 1. General description of panels...4 2. Indications

More information

Control box FSTronic DES-FS

Control box FSTronic DES-FS Control box FSTronic DES-FS Designed for drives of rolling fire shutters and sectional fire gates CONTENT: TECHNICAL REPORT 1. POWER SUPPLY 2. CONFIGURATION 3. INSTALLATION AND SETTING 4. DESCRIPTION OF

More information

EnOcean Parameters: Access Code 20 Note: For use with 902MHz devices ONLY.

EnOcean Parameters: Access Code 20 Note: For use with 902MHz devices ONLY. How to Program: VTST-9 (24V & line-voltage) NOTE: The programming mode has a time limit of 10 minutes. The timer is automatically activated when the programming is started. At the end of the 10 minutes

More information

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB Summary 1 CONNECTIONS... 3 1.1 TEMPERATURE PROBES...3 1.2 LOW VOLTAGE DIGITAL INPUTS...3 1.3 LIVE DIGITAL INPUTS...4 1.4 RELAY OUTPUTS...5 2 POWER SUPPLY... 6 3 SERIAL CONNECTIONS... 6 4 SOFTWARE... 7

More information

Operating Instructions Model: PRT-TS WiFi RF. 01/13 Version 1 Ref: PRT-TSWIFI RF

Operating Instructions Model: PRT-TS WiFi RF. 01/13 Version 1 Ref: PRT-TSWIFI RF Operating Instructions Model: PRT-TS WiFi RF 01/13 Version 1 Ref: PRT-TSWIFI RF Contents Page Setting up your WiFi Thermostat 2-6 Remote Connection Setup 6-8 Pairing with the Receiver 8-12 Display Symbols

More information

Service manual. Type: TD25. Contents

Service manual. Type: TD25. Contents Service manual Type: TD25 Contents Introduction...3 Type overview...4 Programme...5 Indication of programme sequence...5 Options and settings...6 Variant settings...8 Test programme...9 Troubleshooting...11

More information

SmartONE Kit. User Manual

SmartONE Kit. User Manual SmartONE Kit User Manual Thank you for choosing BroadLink DNA series products Packing List Please confirm the items are in good conditions as below SOS SmartONE x1 Wireless Key Fob Remote x1 Wireless Door

More information

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...

More information

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point Medium - Control - System Franke & Haqenest GmbH Borngasse 1a * 04600 Altenburg Tel: 03447-499 313-0 Fax: 03447-499 313-6 email: info@mcs-gaswarnanlagen.de MCS User Guide MCS GasController Microprocessor

More information

3 User s settings. 3.3 Internal clock setting

3 User s settings. 3.3 Internal clock setting 2.9 Subsystem arming In a large building a sub control panel can be enrolled to the JA-63. The subsystem reports all alarms and failures to the main system. The installer can program if the systems will

More information

Electronic Pellet Burner Controller NPBC-V3M

Electronic Pellet Burner Controller NPBC-V3M Electronic Pellet Burner Controller NPBC-V3M SOFTWARE VERSION 3.3a/3.2 page of 27 CHANGES IN THE USER MANUAL OR IN THE CONTROLLER'S SOFTWARE Version of the user manual Changes Page 2.2. The software version

More information

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

Modular Standard HP Chiller 1/4 screw compressor with Carel driver Program for pco¹ pco 2 and pcoc Modular Standard HP Chiller 1/4 screw compressor with Carel driver Manual version 1.0 25 September 2003 Program code: FLSTDmMSDE Do we want you to save you time and money?

More information

Operator's Handbook. Interactive Fire Alarm System Release 3. Information Panel, BV-320. Protecting life, environment and property...

Operator's Handbook. Interactive Fire Alarm System Release 3. Information Panel, BV-320. Protecting life, environment and property... Interactive Fire Alarm System Release 3 Operator's Handbook Information Panel, BV-320 Protecting life, environment and property... ASAFE-IN/FE Rev. A, 010531 COPYRIGHT This publication, or parts thereof,

More information

ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description

ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description Loop Detector is used to detect metal objects such as motor vehicles, motor bikes or trucks. ELSEMA Features Wide supply range: 12.0 to 24 Volts DC 16.0 to 24 Volts AC Selectable sensitivity Pulse or Presence

More information

HILLS Series LED Code Pad User Manual

HILLS Series LED Code Pad User Manual HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2

More information

TWLC - Tempered Water Logic Controller. The Intelligent Control

TWLC - Tempered Water Logic Controller. The Intelligent Control TWLC - Tempered Water Logic Controller The Intelligent Control Chiller Controls Features: Up to six (6) stages: individual board for each stage maximizes redundancy. Menu driven access and programming.

More information

EMBEDDED BASED PROJECTS

EMBEDDED BASED PROJECTS EMBEDDED BASED PROJECTS 1. Real time data acquisition system. 2. Traffic priority for ambulance vehicle. 3. Train collision avoiding system. 4. Remote control switching system. 5. Dtmf switching. 6. Rtc

More information

GARDTEC 580. Installation Instructions

GARDTEC 580. Installation Instructions GARDTEC 5 0 0 S E R I E S GARDTEC 580 Installation Instructions Contents Introduction 1 Planning the Control Panel Location 2 Installation 2 Cable Entries 3 Mains Supply Connection 4 Terminal Block Connections

More information

Protégé Eclipse LED Keypad User Manual PRT-KLES

Protégé Eclipse LED Keypad User Manual PRT-KLES Protégé Eclipse LED Keypad User Manual PRT-KLES The specifications and descriptions of products and services contained in this manual were correct at the time of printing. Integrated Control Technology

More information

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation The most user friendly Contents Section 1 Overview of System 1.1 Kit Contents 1.2 Tools Required 1.3 System Features Security Alarm System L S 4 0 0 Section 2 Planning your Installation 2.1 Location of

More information

FCD-wire Contents. List of Figures

FCD-wire Contents. List of Figures FCD-wire Contents FCD-X21 Configuration 1 Introduction... 1 2 Opening the FCD Application... 1 3 FCD Window... 2 4 FCD LEDs... 3 5 Configuration Operations... 4 FCD Info...4 FCD System Info...5 FCD Interface

More information

Tips how to use the MAS Web tool

Tips how to use the MAS Web tool Tips how to use the MAS Web tool Login options User name: operator You can only view data and settings etc (the only Internet option). User name: config You can do settings and view (option on Intranet)

More information

Paradox Integration Module Settings Guide

Paradox Integration Module Settings Guide Paradox Integration Module Settings Guide List of Terms used in Paradox Integration Module Settings Guide............. 3 Introduction into Paradox Integration Module Settings Guide............... 4 Configuration

More information

Smoke Detector and Siren. Manual

Smoke Detector and Siren. Manual Smoke Detector and Siren Manual 004001 Smoke Detector and Siren Manual Quick Start... 2 Product Description... 2 Installation Guidelines... 3 Behavior within the Z-Wave Network... 3 Operating the Device...

More information

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL Fire Alarm Control Panel & MANUAL CONTENTS SECTION -. Description of the fire control panel fascia.... Alarm.... Reset the system.... Sound and silence the alarms.... Read the Fire, Fault, Test and Disabled

More information

CONTROL DEVICE SLIDETRONIC HD

CONTROL DEVICE SLIDETRONIC HD CONTROL DEVICE SLIDETRONIC HD to control gravity self-closing fire gates Producer: Somati system s.r.o. Jihlavská 510/2c 664 41 Troubsko, okr.brno - venkov Tel.: 547 427 011 Fax: 547 427 013 E-mail: export@somati-system.cz

More information

SERVICE MANUAL VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS. Manual No. '14 KX-SM-202 (OUTDOOR UNIT)

SERVICE MANUAL VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS. Manual No. '14 KX-SM-202 (OUTDOOR UNIT) Manual No. '4 KX-SM-202 SERVICE MANUAL VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS (OUTDOOR UNIT) KXZ series (Heat pump type) Standard series Single use (Used also for combination) FDC280KXZE, 335KXZE,

More information

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide Digiplex System V2.14 / V2.2ACC Control Panel Programming Guide Table of Contents Getting Started...2 What Do I Do First?...2 How Do I Program the Control Panel?...2 Single Digit Entry Method...2 Multiple

More information

COCB_ Circuit Breaker (2 state inputs/ 2 control inputs)

COCB_ Circuit Breaker (2 state inputs/ 2 control inputs) MRS752348-MUM Issued: 0/997 Version: F/23.6.2005 Data subject to change without notice COCB_ Circuit Breaker (2 state inputs/ 2 control inputs) Contents. Introduction... 3. Features... 3.2 Application...

More information

SOFTWARE INTERFACE SPECIFICATION - SOLA MODBUS INTERFACE

SOFTWARE INTERFACE SPECIFICATION - SOLA MODBUS INTERFACE TM SOFTWARE INTERFACE SPECIFICATION - SOLA MODBUS INTERFACE This specificaion interface manual must only be used by a qualified heating installer/service technician. Read all instructions, including this

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Dough Retarder Prover. Service Manual

Dough Retarder Prover. Service Manual Service Manual Revision 3 June 2000 Dough Retarder Prover - Service Manual RBC MKII Controller Revision 6 Page 2 CONTENTS Page(s) 1. INTRODUCTION 3 2. RBC MK 2 CONTROLLER OPERATION 5-9 Process Cycle Overview

More information

Monitor Alarms and Events

Monitor Alarms and Events This chapter contains the following topics: What Are Alarms and Events?, page 1 How are Alarms and Events Created and Updated?, page 2 Find and View Alarms, page 3 Set Alarm and Event Management Preferences,

More information

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual ZX1e ZX2e ZX5e Document No. 996-130 Issue 01 user manual MORLEY-IAS ZX2E/ZX5E Fire Alarm Control Panels Table of Contents 1 INTRODUCTION... 4 1.1 NOTICE... 4 1.2 WARNINGS AND CAUTIONS... 4 1.3 NATIONAL

More information

S INTRUSION&FIRE ALARM AND ACCESS CONTROL PANEL

S INTRUSION&FIRE ALARM AND ACCESS CONTROL PANEL S2000-4 INTRUSION&FIRE ALARM AND ACCESS CONTROL PANEL Installer s and User s manual S2000-4 INTRUSION&FIRE AND ACCEESS CONTROL PANEL ATTENTION! To modify configuration parameters use the program uprog.exe

More information

PumpSaver ISS-105 IS Super Cell Installation Guide

PumpSaver ISS-105 IS Super Cell Installation Guide PumpSaver ISS-105 IS Super Cell Installation Guide Visit our website at www.symcom.com for our complete catalog and new product listings! 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848

More information

OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL. Technicold Marine Systems

OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL. Technicold Marine Systems OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL Technicold Marine Systems www.technicold.com Technicold by Northern Lights 1419 W. Newport Center Drive Deerfield Beach, FL 33442 Tel:

More information

REC-8R Environmental Control. Operation and Installation Manual

REC-8R Environmental Control. Operation and Installation Manual REC-8R Environmental Control Operation and Installation Manual This manual is published by Rotem Computerized Controllers Ltd. All rights to this publication are reserved. No part of this document may

More information

FlameGard 5 UV/IR HART

FlameGard 5 UV/IR HART FlameGard 5 UV/IR HART HART Communication Manual The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized

More information

No part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic,

No part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic, No part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic, mechanical, by photocopying, recording or in any other manner

More information

SPECIAL SPECIFICATION 1646 Digital Loop Vehicle Detector Unit

SPECIAL SPECIFICATION 1646 Digital Loop Vehicle Detector Unit 1993 Specifications CSJ s 2552-03-033 & 2552-1 SPECIAL SPECIFICATION 1646 Digital Loop Vehicle Detector Unit 1. Description. This Item shall govern for furnishing and installing digital loop vehicle detector

More information

REVA Linen Finish Car Operating Panel

REVA Linen Finish Car Operating Panel REVA REVA Linen Finish Car Operating Panel RV 01 RV 03 RV 02 RV 04 RV 06 RV 05 RV 07 5 2 REVA REVA Hairline Finish Car Operating Panel RH 01 RH 03 RH 02 RH 04 RH 06 RH 05 RH 07 REVA REVA Gold Finish Car

More information

FLOW CONTROLLER TYPE S/601

FLOW CONTROLLER TYPE S/601 Checked Version Release date QA V4.2.6 F1 F2 EN 26.01.2012 Manual FLOW CONTROL FLOW CONTROLLER TYPE S/601 MODELS F1 AND F2 INTRODUCTION Thank you for using the S/601 flow and batch control series. This

More information

SALES SUPPORT DOCUMENT

SALES SUPPORT DOCUMENT SALES SUPPORT DOCUMENT ML-322 MAXLOGIC CONVENTIONAL FIRE EXTINGUISHING CONTROL PANEL ML-322 series operates on cross-zone principle, has 4 detection zones and one extinguishing release output which is

More information

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification LMV52 Control Product Description February 3, 2017 The LMV52 is a microprocessor-based burner management system with matching system components for the control and supervision of forced draft burners.

More information

Summit 3208GLD USER MANUAL. Electronics Line

Summit 3208GLD USER MANUAL. Electronics Line Summit 3208GLD USER MANUAL Electronics Line Table of Contents 1: Introduction... 2 2: Overview... 3 3: Keypad Functions... 4 3.1: Keypads... 4 3.2: 3108 LCD Keypad Layout... 4 4: Basic System Operation...

More information

Refrigerator KE T

Refrigerator KE T Refrigerator KE 680-1-3T Service Manual: H8-74-07 Responsible: U. Laarmann KÜPPERSBUSCH HAUSGERÄTE AG E-mail: uwe.laarmann@kueppersbusch.de Tel.: (0209) 401-732 Customer Service Fax: (0209) 401-743 Postfach

More information

ATS UV Monitor Operations Manual

ATS UV Monitor Operations Manual ATS UV Monitor Operations Manual Version 1 as of 09-14 - 2012 Aqua Treatment Service, Inc 194 Hempt Road Mechanicsburg, PA 17050 717. 697. 4998 FA: (800) 787-0197 www.aquat.com Aqua Treatment Service,

More information

Owner s Manual. Part Number 33CS250-RC

Owner s Manual. Part Number 33CS250-RC CONTENTS Page GENERAL... 1 CONFIGURATION... 1-4 Transmitter Display... 1 Transmitter Indicator... 1 Transmitter Front Panel Buttons... 1 Set Clock... 2 Programming Thermostat Schedules... 3 OPERATION...5

More information

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB Summary 1 CONNECTIONS... 8 1.1 TEMPERATURE PROBES...8 1.2 PRESSURE PROBES...9 1.3 LOW VOLTAGE DIGITAL INPUTS...10 1.4 LIVE DIGITAL INPUTS...11 1.5 RELAY OUTPUTS...12 2 VOLTAGE/FREQUENCY INPUT...13 3 POWER

More information

Entero Voice Alarm system.

Entero Voice Alarm system. Entero Voice Alarm system. Entero ESC installation menu guide Rev. 1.0 The manufacturer reserves specification privileges. Information in this manual is subject to change without prior notice or obligation.

More information

APC BC300 Series 40kW 208/450/480V User Guide

APC BC300 Series 40kW 208/450/480V User Guide APC BC300 Series 40kW 208/450/480V User Guide Copyright 2002 APC Denmark ApS This manual is subject to change without notice and does not represent a commitment on the part of the vendor Thank You Thank

More information

QA16 Addressable System

QA16 Addressable System QA16 Addressable System Operating Manual HORING LIH INDUSTRIAL CO., LTD. www.horinglih.com QA16 System Characteristics Each loop can connect with 250 devices. Easy system programming through PC to panel.

More information

Universal tank control WTS Installation and operating instructions for plant engineering companies

Universal tank control WTS Installation and operating instructions for plant engineering companies WELBA Universal tank control WTS-100-2 Installation and operating instructions for plant engineering companies 103497-V026 - by WELBA - 27/11/2018 WELBA GmbH Electronic Control Engineering Gewerbepark

More information

ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling

ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling DataSheet ev 1.12.304/4.0 June 14, 2016 Operating Sequence

More information

SECURIT 700L PLUS ENGINEERING MANUAL

SECURIT 700L PLUS ENGINEERING MANUAL SECURIT 700L PLUS ENGINEERING MANUAL C & K Systems Ltd 13/03/97 C031-096-02 NEW ENHANCED FEATURE SET Securit 700L PLUS Engineering instructions INTRODUCTION The Securit 700L is a microprocessor intruder

More information

THERMOMAX COLTREC RCX 100 MICROPROCESSOR REFRIGERATION CONTROL SYSTEM ENGLISH.

THERMOMAX COLTREC RCX 100 MICROPROCESSOR REFRIGERATION CONTROL SYSTEM ENGLISH. THERMOMAX COLTREC RCX 100 MICROPROCESSOR REFRIGERATION CONTROL SYSTEM ENGLISH www.thermomax-group.com CONTENTS SECTION 1 - INTRODUCTION... 2 SECTION 2 - INSTALLATION... 3 2.1 - RCX 100 UNIT... 4 2.2 -

More information

Security System. User s Guide for the Text Command Center

Security System. User s Guide for the Text Command Center User s Guide for the Text Command Center MY ALARM COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY CONTROL PANEL IS CONNECTED TO THE PHONE JACK LOCATED:

More information

Control/Communicator Installation Manual

Control/Communicator Installation Manual DAS NETWORX NX-12 Control/Communicator Installation Manual General Description...2 Ordering Information...2 Option Definitions...3 Programming the LED Code Pads...5 Programming the NX-12...9 Types of Programming

More information