ICV 2,5/ 6-G-5,08. Extract from the online catalog. Order No.:

Size: px
Start display at page:

Download "ICV 2,5/ 6-G-5,08. Extract from the online catalog. Order No.:"

Transcription

1 Extract from the online catalog ICV 2,5/ 6-G-5,08 Order No.: The figure shows a 10-position version of the product Header, Nominal current: 12 A, Nom. voltage: 320 V, Pitch: 5.08 mm, Number of positions: 6, Color: green, Assembly: Soldering Commercial data EAN Pack 50 pcs. Customs tariff Weight/Piece KG Catalog page information Page 265 (CC-2009) Product notes WEEE/RoHS-compliant since: 01/01/ Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation. The General Terms and Conditions of Use apply to Internet downloads. Technical data Dimensions / positions Length 10.2 mm Pitch 5.08 mm Dimension a 25.4 mm Number of positions 6 Pin dimensions 1,2 x 0,5 PHOENIX CONTACT GmbH & Co. KG Page 1 / 6

2 Hole diameter 1.4 mm Technical data Insulating material group Rated surge voltage (III/3) Rated surge voltage (III/2) Rated surge voltage (II/2) Rated voltage (III/2) Rated voltage (II/2) Connection in acc. with standard Maximum load current Insulating material Inflammability class acc. to UL 94 I 4 kv 4 kv 4 kv 320 V 630 V EN-VDE 12 A 320 V 12 A PA V0 Certificates / Approvals Certification CB, CSA, CUL, GOST, UL, VDE-PZI CSA 300 V 10 A CUL 300 V 10 A UL 300 V 10 A PHOENIX CONTACT GmbH & Co. KG Page 2 / 6

3 Accessories Item Designation Description Assembly FLRP/ICV 80 Pair of guide rails, is inserted into the groove ICV/...G, height: 86 mm, hole diameter: 3.4 mm Plug/Adapter CP-MSTB Keying profile, is inserted into the slot on the plug or inverted header, red insulating material MPS-MT Metal part RPS Reducing plug, Color: gray Additional products Item Designation Description General A-MSTBVA 2,5/ 6-G-5,08 Base strip, Nominal current: 12 A, Nominal voltage: 250 V, Mounting type: DIN rail mounting, Number of positions: 6, Pitch: 5.08 mm, Color: green DFK-MSTB 2,5/ 6-G-5,08 Plug component, Nominal current: 12 A, Nom. voltage: 320 V, Nom. voltage: 320 V, Pitch: 5.08 mm, Number of positions: 6, Color: green, Assembly: Direct mounting DFK-MSTBA 2,5/ 6-G-5,08 Header, Nominal current: 12 A, Nom. voltage: 250 V, Nom. voltage: 250 V, Pitch: 5.08 mm, Number of positions: 6, Color: green, Assembly: Soldering DFK-MSTBVA 2,5/ 6-G-5,08 Header, Nominal current: 12 A, Nom. voltage: 250 V, Nom. voltage: 250 V, Pitch: 5.08 mm, Number of positions: 6, Color: green, Assembly: Soldering EMSTBA 2,5/ 6-G-5,08 Header, Nominal current: 12 A, Nom. voltage: 250 V, Pitch: 5.08 mm, Number of positions: 6, Color: green, Assembly: Press-in EMSTBVA 2,5/ 6-G-5,08 Header, Nominal current: 12 A, Nom. voltage: 200 V, Pitch: 5.08 mm, Number of positions: 6, Color: green, Assembly: Press-in FKIC 2,5/ 6-ST-5,08 Plug component, Nominal current: 12 A, Nom. voltage: 320 V, Pitch: 5.08 mm, Number of positions: 6, Connection type: Springcage conn., Color: green IC 2,5/ 6-ST-5,08 Plug component, Nominal current: 12 A, Nom. voltage: 250 V, Pitch: 5.08 mm, Number of positions: 6, Connection type: Screw connection, Color: green ICC 2,5/ 6-STZ-5,08 Plug component, Nominal current: 12 A, Nom. voltage: 250 V, Pitch: 5.08 mm, Number of positions: 6, Connection type: Crimp connection, Color: green PHOENIX CONTACT GmbH & Co. KG Page 3 / 6

4 MDSTB 2,5/ 6-G1-5,08 Header, Nominal current: 10 A, Nom. voltage: 250 V, Pitch: MDSTBA 2,5/ 6-G-5,08 Header, Nominal current: 10 A, Nom. voltage: 250 V, Pitch: MDSTBV 2,5/ 6-G1-5,08 Header, Nominal current: 10 A, Nom. voltage: 250 V, Pitch: MDSTBVA 2,5/ 6-G-5,08 Header, Nominal current: 10 A, Nom. voltage: 250 V, Pitch: MSTB 2,5/ 6-G-5,08 Header, Nominal current: 12 A, Nom. voltage: 250 V, Pitch: MSTB 2,5/ 6-G-5,08-LA Header, Nominal current: 12 A, Nom. voltage: 250 V, Pitch: 5.08 mm, Number of positions: 6, Assembly: Soldering MSTBA 2,5/ 6-G-5,08 Header, Nominal current: 12 A, Nom. voltage: 250 V, Pitch: MSTBA 2,5/ 6-G-5,08 THT Header, Nominal current: 12 A, Nom. voltage: 250 V, Pitch: 5.08 mm, Number of positions: 6, Color: black, Assembly: SMD/THT/ THR MSTBA 2,5/ 6-G-5,08-LA Header, Nominal current: 12 A, Nom. voltage: 250 V, Pitch: 5.08 mm, Number of positions: 6, Assembly: Soldering MSTBO 2,5/ 6-GL-5,08 Header, Nominal current: 8 A, Nom. voltage: 250 V, Pitch: MSTBO 2,5/ 6-GR-5,08 Header, Nominal current: 8 A, Nom. voltage: 250 V, Pitch: MSTBV 2,5/ 6-G-5,08 Header, Nominal current: 12 A, Nom. voltage: 250 V, Pitch: MSTBVA 2,5/ 6-G-5,08 Header, Nominal current: 12 A, Nom. voltage: 250 V, Pitch: MSTBVA 2,5/ 6-G-5,08 THT Header, Nominal current: 12 A, Nom. voltage: 250 V, Pitch: 5.08 mm, Number of positions: 6, Color: black, Assembly: SMD/THT/ THR MSTBW 2,5/ 6-G-5,08 Header, Nominal current: 12 A, Nom. voltage: 250 V, Pitch: SMSTB 2,5/ 6-G-5,08 Header, Nominal current: 12 A, Nom. voltage: 250 V, Pitch: SMSTBA 2,5/ 6-G-5,08 Header, Nominal current: 12 A, Nom. voltage: 250 V, Pitch: 5.08 PHOENIX CONTACT GmbH & Co. KG Page 4 / 6

5 Diagrams/Drawings Drilling plan/solder pad geometry Dimensioned drawing PHOENIX CONTACT GmbH & Co. KG Page 5 / 6

6 Address PHOENIX CONTACT GmbH & Co. KG Flachsmarktstr Blomberg,Germany Phone Fax Phoenix Contact Technical modifications reserved; PHOENIX CONTACT GmbH & Co. KG Page 6 / 6

CUSTOMS UNION COMPLIANCE CERTIFICATE No. TC RU C-GB.MH04.B Series RU No

CUSTOMS UNION COMPLIANCE CERTIFICATE No. TC RU C-GB.MH04.B Series RU No EAC COMPLIANCE CERTIFICATE No. TC RU C-GB.MH04.B.00286 Series RU No. 0207965 AUTHORITY FOR CERTIFICATION of products of Research and Development Centre TECHNOPROGRESS, accreditation certificate No. РОСС

More information

Introducing Hermaphroditic Blade and Receptacle Connector

Introducing Hermaphroditic Blade and Receptacle Connector Introducing Hermaphroditic Blade and Receptacle Connector Wire-to-Board, Board-to-Board and Dust Cover Hermaphroditic Blade and Receptacle Connector : Wire-to-Board KEY FEATURES Available in 2, 4, and

More information

AXICOM Telecom-, Signal and RF Relays. Cradle Relay Accessories and Mounting Nov. 07 Rev. C ECOC: JM10

AXICOM Telecom-, Signal and RF Relays. Cradle Relay Accessories and Mounting Nov. 07 Rev. C ECOC: JM10 Cradle Relay Accessories and Mounting 108-98016 Nov. 07 Rev. C ECOC: JM10 Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet,

More information

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC Engineering Guideline pac-carriers Type 9195 for TRICON system TRICONEX TMR PLC 2 Engineering Guideline TRICON system 14.10.2009 Content Signal type Control system I/O cards type pac-carrier Channels Slots

More information

Fire Alarm/Life Safety Cable 6

Fire Alarm/Life Safety Cable 6 Electronics Fire Alarm/Life Safety 6 Index Page Alarm and Security Solutions Guide 114-116 Fire alarm systems have expanded from a rather simple and unsophisticated business configured upon large, electromechanical

More information

Z-PACK TinMan 85 ohm Connector Overview

Z-PACK TinMan 85 ohm Connector Overview Z-PACK TinMan 85 ohm High Speed Backplane Connector Z-PACK TinMan 85 ohm Connector Overview Product Facts 10+ Gbps performance 85 ohm impedance for differential pair configuration 5 pair version offers

More information

ClimaSys Resistance heaters Selection guide

ClimaSys Resistance heaters Selection guide Selection guide Insulated resistance heaters Power W Voltage Type of connection Terminal block Cable 87504 10 12-36 DC X 87501 10 110-250 AC X 87512 21 12-36 DC X 87502 21 110-250 AC X 87518 55 12-36 DC

More information

Wiring Duct Product Selection Guide

Wiring Duct Product Selection Guide Wiring Duct Product Selection Guide Comprehensive Wiring Duct Solutions PVC Flush Cover Wiring Duct Standard 2m lengths, sold base and cover together. Type ENC, Narrow Slots, Narrow Fingers Type EWC, Wide

More information

Trade Product List 2013 BIOMASS ACCESSORIES

Trade Product List 2013 BIOMASS ACCESSORIES Trade Product List 2013 BIOMASS ACCESSORIES BIOMASS SYSTEM COMPONENTS Constant Temperature Control Accessories CONSTANT TEMPERATURE CONTROL PRODUCTS Order Code Description of Package and Contents Pictures

More information

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C PSD1001C INSTRUCTION MANUAL SIL 3 SIL 2 IIB Group Power Supply for Hazardous Area Equipment DINRail Model PSD1001C PSD1001C SIL 3 SIL 2 IIB Group Power Supply for hazardous Area Equipment ISM006510 General

More information

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes Spec-728 CPH FX ( McLean Electronics Cooling Sealed Enclosure Cooling McLean Electronics Cooling: Sealed Enclosure Cooling SPECTRACOOL Indoor/Outdoor G57 2 BTU/Hr. 5861 Watt G52 8/12 BTU/Hr. 23/35 Watt

More information

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac- Carriers Type Universal Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art

More information

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage LINETRAXX VME420 Multi-functional monitoring relay for undervoltage, overvoltage and frequency monitoring in AC/DC systems with separate supply voltage VME420_D00026_01_D_XXEN/06.2016 LINETRAXX VME420

More information

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 505 Grünberg Tel.: 00 807-0 Fax: 00 807-259 Insulation monitoring device for unearthed AC/DC systems (IT systems for the supply of operating theatre

More information

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) T M 1 isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012372 / 03.2015 isopv

More information

Helically wound resistance wire coil made

Helically wound resistance wire coil made Ceramic Insulated CHANNEL STRIP HEATERS A Reliable Heat Source with Seamless Stainless Steel Sheath For Flat Surface Mounting Installations, Used in Hundreds Of Industrial and Commercial Heating Applications...

More information

Telecom Fuses. Benefits. Features. Applications

Telecom Fuses. Benefits. Features. Applications Telecom Fuses The FT600 fuse series is designed to assist telecommunications equipment manufacturers in complying with North American overcurrent protection requirements, including Telcordia GR- 1089,

More information

SPECTRACOOL INDOOR/OUTDOOR

SPECTRACOOL INDOOR/OUTDOOR SPEC-728 E SEALED ENCLOSURE AIR CONDITIONERS SEALED ENCLOSURE AIR CONDITIONERS SPECTRACOOL INDOOR/OUTDOOR G57 2 BTU/Hr. 5861 Watt G52 8/12 BTU/Hr. 23/35 Watt G28 4/6 BTU/Hr. 1172/ Watt Clean AirFlow Ambient

More information

Printed Circuit Board Connectors

Printed Circuit Board Connectors Printed Circuit Board Overview Printed circuit board or PCB connectors are heavy duty environmentally sealed connectors designed for wire-to-circuit board connections. TE Connectivity Industrial & Commercial

More information

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry LINETRAXX VMD420 Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry VMD420_D00137_02_D_XXEN/06.2016 LINETRAXX VMD420 Multi-functional

More information

Indoor and Outdoor Enclosures Outdoor Nema 3, 3R, 4, 4X Cabinet Enclosures LTE 4G Wimax Telecom Security Traffic

Indoor and Outdoor Enclosures Outdoor Nema 3, 3R, 4, 4X Cabinet Enclosures LTE 4G Wimax Telecom Security Traffic Spec-00698 APH FX ( Protective Cooling Air Conditioners N28 Narrow Indoor/Outdoor Base Models Features R407c and R134a earth-friendly refrigerants and RoHS compliant Models for 115, 230 AC volt power input

More information

5736 N. Michigan Road Indianapolis, IN 46228

5736 N. Michigan Road Indianapolis, IN 46228 763.576.3200 SPEC-00728 H763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners SPECTRACOOL INDOOR/OUTDOOR G57 BTU/Hr. Watt G52 / BTU/Hr. 2300/3500 Watt

More information

5736 N. Michigan Road Indianapolis, IN 46228

5736 N. Michigan Road Indianapolis, IN 46228 763.576.32 SPEC-728 H763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners SPECTRACOOL INDOOR/OUTDOOR G57 2 BTU/Hr. 5861 Watt G52 8/12 BTU/Hr. 23/35 Watt

More information

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE Insulation monitoring device with integrated load and temperature monitoring and locating current injector for insulation fault location systems for medical IT systems _D00043_02_D_XXEN/09.2016 Insulation

More information

AMP SUPERSEAL 1.5 SERIES Connectors

AMP SUPERSEAL 1.5 SERIES Connectors Introduction TE Connectivity has developed the MP SUPERSEL 1.5 SERIES Connector family to meet the increasing requirements for reliability and water proofness. MP SUPERSEL 1.5 SERIES Connector exceed the

More information

G /6000 BTU/Hr. 1172/1758 Watt

G /6000 BTU/Hr. 1172/1758 Watt Spec-728 E Sealed Enclosure Air Conditioners Sealed Enclosure Air Conditioners SPECTRACOOL Indoor/Outdoor G57 2 BTU/Hr. 5861 Watt G52 8/12 BTU/Hr. 23/35 Watt G28 4/6 BTU/Hr. 1172/ Watt Clean AirFlow Ambient

More information

SPECTRACOOL Indoor & Outdoor Air Conditioners

SPECTRACOOL Indoor & Outdoor Air Conditioners PH FX ( Product Overview : SPECTRACOOL Indoor & Outdoor Air Conditioners G52 Indoor Model G57 Outdoor Model G28 Indoor Model 18 18 Product Overview : Makes electronics cooling easier, so you can go about

More information

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM Ceramic Insulated A Reliable Heat Source with Seamless Stainless Steel Sheath Flat Surface Mounting Installations Used in Hundreds of Industrial and Commercial Heating Applications Typical Applications

More information

Ordering Key. Dielectric strength

Ordering Key. Dielectric strength Controllers AC Semiconductor Controller Type Soft starting and stopping of 3-phase squirrel cage motors Low inrush and reduced vibration during starting Integrated bypassing of semiconductors Rated operational

More information

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM Ceramic Insulated A Reliable Heat Source with Seamless Stainless Steel Sheath Flat Surface Mounting Installations Used in Hundreds of Industrial and Commercial Heating Applications Typical Applications

More information

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems) ISOMETER IR425 Insulation monitoring device for unearthed AC/DC control circuits (IT systems) IR425-D4_D00039_04_D_XXEN/05.2017 ISOMETER IR425 Insulation monitoring device for unearthed AC/DC control circuits

More information

SM CONNECTOR. 1Certified LR R Specifications. Standards. 2.5mm pitch/disconnectable Crimp style wire-to-wire connectors

SM CONNECTOR. 1Certified LR R Specifications. Standards. 2.5mm pitch/disconnectable Crimp style wire-to-wire connectors .mm pitch/disconnectable Crimp style wire-to-wire connectors The SM series are.mm pitch, wire-to-wire connectors that perform reliably in high-density, small current applications. High contact pressure

More information

Part Number Structure ZA 016 L D CT

Part Number Structure ZA 016 L D CT Product Application Guide- 22mm Industrial Alarms with Terminal Block Part Number Structure ZA 016 L D CT Series: ZA = 22mm Maximum Voltage: 016 = 6-16; 028 = 16-28; 048 = 28-48; 120 = 48-120 Sound Level:

More information

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016 LINETRAXX RCMA420 Residual current monitor for monitoring AC,

More information

GENESIS Indoor Air Conditioners

GENESIS Indoor Air Conditioners Product Overview : Indoor Air Conditioners M28 Model M52 460 Volt 3-Phase Model M17 Model 68 68 Product Overview : The specifier s choice for cooling industrial process controls Indoor Air Conditioners

More information

EL-OEM-3 OEM Packaged Voltage Data Logger

EL-OEM-3 OEM Packaged Voltage Data Logger FEATURES PCB Mounted (2.54mm pitch, header sockets) 0 to 2.4V d.c. Measurement Range Logging Rates between 1s and 12hr Stores 64,000 readings USB interface for set-up and data download (USB connector not

More information

Installation / Monitoring Technique

Installation / Monitoring Technique Installation / Monitoring Technique INFOMSTER Common larm System, us Connection New- / First- /Common Signal nnunciator RP 5994, RP 5995 Replacements for: N 5969, N 5970, N 597 055005 Circuit Diagrams

More information

T BTU/Hr. 234 Watts. T BTU/Hr. 586 Watts. Air Conditioners

T BTU/Hr. 234 Watts. T BTU/Hr. 586 Watts. Air Conditioners 763.576.32 Spec-733 C763.422.2211 Sealed Enclosure Air Conditioners Sealed Enclosure Air Conditioners T-SERIES Compact Outdoor T15 8 BTU/Hr. 234 Watts T2 2 BTU/Hr. 586 Watts INDUSTRY STANDARDS UL/cUL Listed;

More information

Top-Mount Air Conditioners

Top-Mount Air Conditioners Product Overview Top-Mount Air Conditioners MHB11 Model 92 92 Product Overview The perfect cooling solution when side-mount air conditioning is not an option Top-Mount Air Conditioners PRODUCT OVERVIEW

More information

Unpacking, Assembly, and Installation Guide ENGLISH. Page 1 to 10

Unpacking, Assembly, and Installation Guide ENGLISH. Page 1 to 10 FJ-500 * FJ-400 Unpacking, Assembly, and Installation Guide ENGLISH Page 1 to 10 1 Contents About This Manual... 1 1 How to Unpack the FJ-500/400... 2 1-1 Overview of Packed Materials... 2 1-2 Open the

More information

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible LiteMinder Fast Transfer System 1.0 to 18.75KVA LED Compatible Series Pure Sine Wave Modular Technology Modular AC System Evenlite s LiteMinder Central System provides an innovative Emergency Lighting

More information

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305 High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305 The new high-power Q305 laser is an expansion of the existing Q-Series that provides a solution for demanding applications requiring faster throughput.

More information

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas UL 1203 CSA C22.2 NO. 30-M1986 The D1xS1 and D1xS2 Alarm Horns also comply with the following standards for signaling

More information

Line Isolation Monitor (LIM) LIM2000plus

Line Isolation Monitor (LIM) LIM2000plus Line Isolation Monitor (LIM) LIM2000plus for Single and Three Phase Systems TDB207005usa/10.2008 BENDER Group Line Isolation Monitor LIM2000plus for Single and Three Phase Systems LIM2000plus Device features

More information

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015 pac-carrier Type 9195 Integration of conventional

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

SPECTRACOOL Indoor & Outdoor Air Conditioners

SPECTRACOOL Indoor & Outdoor Air Conditioners Product Overview : SPECTRACOOL Indoor & Outdoor Air Conditioners G52 Indoor Model G57 Outdoor Model 18 Product Overview : Makes electronics cooling easier, so you can go about your business SPECTRACOOL

More information

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances _D00108_00_D_XXEN/05.2015 ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances

More information

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date: Installation and Operating instructions for C9900-U330-0010 battery pack Version: 2.0 Date: 2017-03-23 Table of contents Table of contents 1 Foreword 3 1.1 Notes on the Documentation 3 1.1.1 Liability

More information

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE / 3 GM20 Digital Ground Continuity Relay For AC Systems Technical Bulletin NAE03230 / 0.20 GM20 Ground continuity monitor For AC systems Description The GM20 monitors the loop resistance of ground conductors

More information

PRODUCT DESCRIPTION. Renovation smoke exhaust fumivent VdS

PRODUCT DESCRIPTION. Renovation smoke exhaust fumivent VdS PRODUCT DESCRIPTION Renovation smoke exhaust fumivent 4000-11-VdS 04.2016 2 General description The fumivent 4000-11-VdS renovation smoke exhaust can be used to quickly and safely refurbish defective smoke

More information

SCR/SCRF Series Battery Charger

SCR/SCRF Series Battery Charger JD0036-00 Installing and Calibrating the Combined Alarm-Status Monitor (CASM) Scope Reference Materials Required 1. Installing a new CASM option (EJ0837-##) 1 2. Replacing a CASM circuit board (EN0014-##)

More information

Power. Average noise level (DIN EN ISO 4871)

Power. Average noise level (DIN EN ISO 4871) 21m 3 /h to 102m 3 /h Very low noise Minimal depth in Functional design Time-saving installation Filter fans are used to provide an optimum climate in s. The interior temperature of an can be reduced by

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS The SensorNet I/O Module provides attachment for up to 32 alarms and up to 16 switched devices. An RS-232 or RS-422 communications port is also provided for receiving serial alarms.

More information

AUTOMOTIVE MINIATURE WIRE (AMW)

AUTOMOTIVE MINIATURE WIRE (AMW) 0.13 mm 2 and 0.17 mm 2 AUTOMOTIVE MINIATURE WIRE (AMW) T4 (150 C/3000 hrs) TE AUTOMOTIVE /// AUTOMOTIVE MINIATURE WIRE (AMW) 0.13 mm 2 and 0.17 mm 2 AUTOMOTIVE MINIATURE WIRE (AMW) T4 (150 C/3000 hrs)

More information

MSM - Expansion modules

MSM - Expansion modules MSM - Expansion modules Transistor- and relay modules for devices of the MSM-product family Free assignment of the output arrays to the input arrays of the annunciator Triggering of relays or transistor

More information

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems) Insulation monitoring device for unearthed AC/DC control circuits (IT systems) TDB103005en/05.2013 Insulation monitoring device for unearthed AC/DC control circuits (IT systems) Product description The

More information

CURRENT LIMITING LIGHTING CONTROL PANEL Supplemental Overcurrent Protection City of Los Angeles Approved Version

CURRENT LIMITING LIGHTING CONTROL PANEL Supplemental Overcurrent Protection City of Los Angeles Approved Version Project: Fixture Type: Location: Contact/Phone: CURRENT LIMITING LIGHTING CONTROL PANEL Supplemental Overcurrent Protection City of Los Angeles Approved Version PRODUCT DESCRIPTION The Juno Trac-Master

More information

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description

More information

FTTX FIBER OPTIC CABINET PACKAGE, TYPE 4X

FTTX FIBER OPTIC CABINET PACKAGE, TYPE 4X 763.422.2600 SPEC-00216 J763.422.2211 OUTSIDE PLANT PRODUCTS FIBER OPTIC CABINETS FTTX FIBER OPTIC CABINET PACKAGE, TYPE 4X Door Switch 19-or 23-inch rack mounting including cabinet entry boots Ground

More information

AMP SUPERSEAL 1.5 SERIES Connectors

AMP SUPERSEAL 1.5 SERIES Connectors Introduction Tyco Electronics has developed the MP SUPERSEL 1.5 SERIES Connector family to meet the increasing requirements for reliability and water proofness. MP SUPERSEL 1.5 SERIES Connector exceed

More information

PCB Relays Single Relays

PCB Relays Single Relays Features Small power relay Limiting continuous current 30 A Minimal weight Low noise operation Wave (THT) and reflow (THR/pin-in-paste) solderable versions For twin version refer to Double Micro Relay

More information

Inverted Through Board Surface

Inverted Through Board Surface Inverted Through Board Surface Application Specification Mount Technology (SMT) 114-13245 Connector Assembly 14 DEC 09 Rev E NOTE i All numerical values are in metric units [with U.S. customary units in

More information

Introducing SlimSeal SSL Connector

Introducing SlimSeal SSL Connector Introducing SlimSeal SSL Connector The SlimSeal SSL connectors are low profile, single row connectors developed for indoor and outdoor LED lighting applications. These connectors provide low power, sealed

More information

Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Stacking Height mm inch

Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Stacking Height mm inch Stacking Height Guide for Parallel Board-to-Board Applications Fine Pitch SMT Stacking Stacking Height Guide for Parallel Board-to-Board Applications (Continued) Stacking Height mm inch Connector Description

More information

PROAIR Harsh Environment/Wash Down Air Conditioners

PROAIR Harsh Environment/Wash Down Air Conditioners PH FX ( Product Overview McLean Cooling Technology: Air Conditioners: Harsh Environment/Wash Down Air Conditioners CR23 CR23st CR43st CR29 102 Product Overview : The ultimate in protective cooling for

More information

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491 Bender Incorporated 700 Fox Chase, Coatesville PA 1930 Tel.: (800) 356-466 Fax: (610) 383-7100 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control function

More information

C-Bus Four Channel Analogue Output Unit Installation Instructions

C-Bus Four Channel Analogue Output Unit Installation Instructions C-Bus Four Channel Analogue Output Unit Installation Instructions 5504AMP Series REGISTERED PATENT Table of Contents Section... Page 1.0 Product Range...3 2.0 Description...3 3.0 Capabilities...3 4.0 Wiring

More information

Marathon Special Products

Marathon Special Products Marathon Special Products Fused Disconnect Switch Specifications 30 amps 600 volts AC Line/Load #4-18 AWG Factory & Field Wiring Minimum indicator voltage 90V-AC Din-Rail mountable on any 35mm wide rail

More information

Operating Manual Distribution box

Operating Manual Distribution box Distribution box Operation manual Distribution box 27-5452-... Type 27-5452-... EN 1/12 EN 2/12 1. Product description The distribution boxes Type 27-5452-... are used for connections and distribution

More information

Crimping tools for D-Sub contacts Crimping tools for other contacts Crimping machine TC-C

Crimping tools for D-Sub contacts Crimping tools for other contacts Crimping machine TC-C Contents Page Hand crimping tools for Han standard contacts... 90.4 Pneumatic crimping tools for Han standard contacts... 90.9 Crimping tools for D-Sub contacts... 90.11 Crimping tools for Han TC high

More information

Remote alarm indicator and test combination MK2430

Remote alarm indicator and test combination MK2430 Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Tel.: 040 807-0 Fax: 040 807-259 Remote alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC

More information

Oil & Gas Industry. Magnecraft Relay Solutions

Oil & Gas Industry. Magnecraft Relay Solutions This document is designed to help you understand and identify opportunities in the Oil & Gas market and to provide insight and advice on how to sell Magnecraft relays. The following information is included:

More information

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC Operating Instructions We have designed the new MVP-D-TEK vehicle loop detector with the following objectives in mind: 1. Compact package to allow

More information

Annunciators, 8 LED. D7030X, D7030X-S2, and D7030X-S8. Installation Manual

Annunciators, 8 LED. D7030X, D7030X-S2, and D7030X-S8. Installation Manual Annunciators, 8 LED D7030X, D7030X-S2, and D7030X-S8 en Installation Manual Annunciators, 8 LED Notices en 3 1 Notices These instructions cover the installation of the D703X, D7030X-S2, and D7030X-S8

More information

Power Blocks - Splicer/Distribution

Power Blocks - Splicer/Distribution POWER BLOCKS Power Blocks - Splicer/Distribution Electrical 60-2280 amps 600 volts AC/DC (UL) Flexible stranded wire compliant Multiple wire rating - refer to data sheets for details Listed products provide

More information

Quick Reference Guide Barrier Strips

Quick Reference Guide Barrier Strips Quick Reference Guide Barrier Strips Barrier strip style terminal blocks from Tyco Electronics are available in 3 main categories: dual-barrier, tri-barrier, and double row. Each category of barrier strip

More information

FTTX Fiber Optic Cabinet Package, Type 4X

FTTX Fiber Optic Cabinet Package, Type 4X Spec-00216 Outside Plant Products Fiber Optic Cabinets FTTX Fiber Optic Cabinet Package, Type 4X Door Switch 19-or 23-inch rack mounting including cabinet entry boots Ground Bus Bar Battery Cabinet Door

More information

electronics Protection

electronics Protection Climate control electronics PROTECTION 10/2017 PRODUcT catalog WWW.SCHROFF.PENTAIR.co.uk Main Catalogue Content Cabinets...... 1 Climate control Overview Wall mounted cases......... 2 Accessories for cabinets

More information

You work hard on your panel. we work hard in your panel. PRODUCTS FOR

You work hard on your panel. we work hard in your panel. PRODUCTS FOR You work hard on your panel we work hard in your panel. PRODUCTS FOR 2 PRODUCTS FOR You simply won t find better panel components. Thomas & Betts has everything you need to make your panel better than

More information

SERVICE MANUAL FOR MODEL RM-26

SERVICE MANUAL FOR MODEL RM-26 SERVICE MANUAL FOR MODEL RM-26 REQUIRED TOOLS CORDLESS DRILL DRIVE CUTTING TUBING OPEN WRENCH OF 1/2 RATCHET WITH SOCKET OF 7/16 SCREWDRIVER SET WITH SOCKET OF 9/32 VISE GRIP PIERCING VALVE WATCHER SLOTTED

More information

THE SOLUTION. MSM-Product family OPERATING MANUAL. A fault annunciator of the. BSM Basic fault annunciator for panel mounting. INFOwww.ees-online.

THE SOLUTION. MSM-Product family OPERATING MANUAL. A fault annunciator of the. BSM Basic fault annunciator for panel mounting. INFOwww.ees-online. A fault annunciator of the MSM-Product family 17.07.2006 BSM Basic fault annunciator for panel mounting INFOwww.ees-online.de Contents overview 1 Validity 3 2 General notes 3 2.1 Used symbols 4 2.2 Used

More information

C-Bus Four Channel General Input Unit Installation Instructions

C-Bus Four Channel General Input Unit Installation Instructions C-Bus Four Channel General Input Unit Installation Instructions 5504GI Series REGISTERED DESIGN REGISTERED PATENT Table of Contents Section...Page 1.0 Product Range... 3 2.0 Description... 3 3.0 Capabilities...

More information

GET.64 Interconnection System. RoHS. Ready

GET.64 Interconnection System. RoHS. Ready GET.64 Interconnection System RoHS Ready TYCO ELECTRONICS GLOBAL AUTOMOTIVE DIVISION THE 5 APPLICATION AREAS 1 INNOVATIVE TECHNOLOGIES Tyco Electronics is the world s largest passive electronic components

More information

* Consult factory on conditions for approval acceptability

* Consult factory on conditions for approval acceptability 6 Introduction Guide Guide to Power Protection How various power protection devices work How to use power protection devices 39 6600 Series Sub-miniature bimetal thermostat 8-PIN DIP package configuration

More information

Introduction to Flow Switch

Introduction to Flow Switch Introduction to TM Solutions Flow Detection, Switching & Control Flow switches detect a change in state from flow or no-flow within pipe or ducting. Correspondingly, the sensor inverts a contact to signal

More information

Universal fault annunciator for panel mounting

Universal fault annunciator for panel mounting Universal fault annunciator for panel mounting Communication over Ethernet USM - Universal-fault annunciator for panel mounting Low depth housing for panel mounting Versions with 8, 16, 32 or 48 inputs

More information

Technical information

Technical information Quality in Quantity Integrated management system The objective of the Phoenix Contact integrated management system is to coordinate all the requirements regarding products, processes and organization.

More information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information INSTRUCTION MANUAL D1xB2XH1 Xenon Beacon For use in Hazardous Locations 2) Rating & Marking Information 2.1 Public Mode Fire Alarm Ratings The D1xB2XH1 is certified for use as public mode visual alarm

More information

Optimise wire processing A comprehensive range of products for the workshop

Optimise wire processing A comprehensive range of products for the workshop Optimise wire processing A comprehensive range of products for the workshop Forward-looking process optimisation Cutting to length, stripping and crimping the faster and more accurately these routine tasks

More information

SPECIALISTS IN CONNECTING TECHNOLOGIES AND ENCLOSURES.

SPECIALISTS IN CONNECTING TECHNOLOGIES AND ENCLOSURES. SPECIALISTS IN CONNECTING TECHNOLOGIES AND ENCLOSURES www.hitaltech.com Our Vision To be recognised in the market as a specialist of Electromechanical solutions within the electronic manufacturing industry

More information

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information INSTRUCTION MANUAL D1xB2XH2 Xenon Beacon For use in Hazardous Locations 2) Rating & Marking Information 2.1 Public Mode Fire Alarm Ratings The D1xB2XH2 is certified for use as public mode visual alarm

More information

In installation with more doors, up to 64 central units can be used together, allowing installations of up to 2,048 doors. RECEPTION CAR PARK

In installation with more doors, up to 64 central units can be used together, allowing installations of up to 2,048 doors. RECEPTION CAR PARK Access Control CENTRALISED CAC The CAC (centralised access control ) allows complex installations with several accesses and additional functions. It also makes it possible to integrate other services:

More information

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74 AM54 Instruction Bulletin North American Installation Addendum Document Number PN25016 Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

More information

LOW POWER AND SIGNAL APPLICATION GUIDE APPLIANCES /// LOW POWER & SIGNAL APPLICATION GUIDE

LOW POWER AND SIGNAL APPLICATION GUIDE APPLIANCES /// LOW POWER & SIGNAL APPLICATION GUIDE LOW POWER AND SIGNAL APPLICATION GUIDE MORE SOLUTIONS TE Connectivity s (TE) extensive connector and sensor solutions provide the essential connectivity you need for your daily interactions at home and

More information

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15 with coupling device AGH675-7 and AGH675-7MV15 Device combination for insulation monitoring in unearthed AC, AC/DC and DC power systems (IT systems) IRDH275BM-7_D00123_03_D_XXEN/01.2017 with coupling device

More information

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) IRDH375_D00124_01_D_XXEN/07.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Product

More information

VAMP 120 & 121. Arc flash detection units. Product picture

VAMP 120 & 121. Arc flash detection units. Product picture Arc flash detection units VAMP 120 and 121(D) are extremely fast arc flash detection units for LV and MV switchgear and controlgear. The units are especially designed to increase the safety and to minimize

More information

Part Number Structure ZT 028 L D CT R 15

Part Number Structure ZT 028 L D CT R 15 Product Application Guide- 22mm Industrial Alarms with LED Lights Part Number Structure ZT 028 L D CT R 15 Series: ZT = 22mm with LED Maximum Voltage: 016 = 9-16; 028 = 20-28; 120 = 48-120 Sound Level:

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D1xC COMBINED RADIAL HORNS & STROBES For Use In Hazardous Locations - Gas 3) Ratings and Markings The D1xC1 and D1xC2 combined alarm horns and strobes comply with the following

More information