CUSTOMS UNION COMPLIANCE CERTIFICATE No. TC RU C-GB.MH04.B Series RU No
|
|
- Brent Watts
- 6 years ago
- Views:
Transcription
1 EAC COMPLIANCE CERTIFICATE No. TC RU C-GB.MH04.B Series RU No AUTHORITY FOR CERTIFICATION of products of Research and Development Centre TECHNOPROGRESS, accreditation certificate No. РОСС RU MH04 dated 15/05/2013 issued by Federal Service for Accreditation (Rosakkreditatsiya). Registered address: Russia, , Moscow, Velozavodskaya street, 9. Actual address: Russia, , Moscow, Kozhevnicheskaya street, 14, building 2. Telephone/fax: +7 (495) , APPLICANT ATEKS-Electro Limited Liability Company, Principal State Registration Number , registered and actual address: room 20H, letter A, Kolomyazhskiy ave., 27, Saint Petersburg, , Russian Federation. Telephone: +7 (812) , fax: +7 (812) , MANUFACTURER Abtech Limited, registered and actual address: , Newhall Road, Lower Don Valley, Sheffield, South Yorkshire, S9 2QJ, Great Britain. PRODUCTS Explosion-proof boxes of SSX, BPG / BPGC, ZAG, HVJB, SSXU, BPGU /BPGCU, ZAGU series with explosion protection marking according to appendix on form No , manufactured in accordance with technical documentation of the manufacturer. Serial production. Customs Union Customs Commodity Code MEETS THE REQUIREMENTS of Customs Union technical regulations On Safety of Equipment for Operation in Explosive Environments (TR TS 012/2011). CERTIFICATE IS ISSUED ON THE BASIS OF Certification test reports Nos. 2918Ex, 2919Ex dated 27/05/2015, 2920Ex, 2921Ex dated 28/05/2015, 2922Ex, 2923Ex, 2924Ex dated 24/05/2015 issued by test laboratory of CJSC Research and Development Centre TECHNOPROGRESS, accreditation certificate No. РОСС RU MH04). ADDITIONAL INFORMATION Storage conditions for group 1Л in accordance with GOST The assigned storage time is 3 years. The specified lifetime is 12 years provided the usage instructions specified by the manufacturer in al documentation are followed. The additional product identification information is provided in appendices on forms Nos to VALIDITY TERM IS FROM 29/05/2015 THROUGH 28/05/2020. (experts (auditor experts))
2 Sheet 1 Series RU No List of products covered by the compliance certificate Customs Union Customs Commodity Code Name, type, grades, models of products, product or system components Explosion-proof boxes: series SSX with explosion protection marking: 1Ex e IIC T6 Gb X / Ex tb IIIC T85 C Db X 0Ex ia IIC T6 Ga X / Ex ta IIIC T85 C Da X 1Ex ib IIC T6 Gb X / Ex tb IIIC T85 C Db X 1Ex e IIC T5 Gb X / Ex tb IIIC T100 C Db X 0Ex ia IIC T5 Ga X / Ex ta IIIC T100 C Da X 1Ex ib IIC T5 Gb X / Ex tb IIIC T100 C Db X 1Ex e IIC T3 Gb X / Ex tb IIIC T200 C Db X 0Ex ia IIC T3 Ga X / Ex ta IIIC T200 C Da X 1Ex ib IIC T3 Gb X / Ex tb IIIC T200 C Db X series BPG / BPGC with explosion protection marking: 1Ex e IIC T6 T4 Gb X / Ex tb IIC T85 C T100 C Db X 01Ex ia IIC T6 T4 Ga X / Ex ta IIC T85 C T100 C Da X 1Ex ib IIC T6 T4 Gb X / Ex tb IIC T85 C T100 C Db X series ZAG with explosion protection marking: 1Ex e IIC T6 T3 Gb X / Ex tb IIIC T85 C T100 C Db X 0Ex ia IIC T6 T3 Ga X / Ex tb IIIC T85 C T100 C Da X 1Ex ib IIC T6 T3 Gb X / Ex tb IIIC T85 C T100 C Db X series HVJB with explosion protection marking: 1Ex e IIC T4 Gb X / Ex Tb IIIC T70 C Db X 1Ex e IIC T150 C (T3) Gb X / Ex tb IIIC T110 C Db X series SSXU with explosion protection marking: Ex e IIC Gb U Ex ia IIC Ga U Ex ib IIC Gb U Series BPGU / BPGCU with explosion protection marking: Ex e IIC Gb U Ex ia IIC Ga U Ex ib IIC Gb U series ZAGU with explosion protection marking: Ex e IIC Gb U Ex ib IIC Gb U Designation of documentation based on which the products are manufactured Manufacturer s technical documentation (experts (auditor experts))
3 Sheet 2 Series RU No Function and application field The explosion-proof boxes of SSX, BPG / BPGC, ZAG, HVJB, SSXU, BPGU / BPGCU, ZAGU series with explosion protection marking according to appendix on form No (hereafter referred to as boxes ) are designed for connection and switching of electric circuits and as housings for deployment of various components. The application field is different explosion hazard zones of premises and outdoor installations in accordance with the assigned explosion protection marking, requirements of GOST IEC and Industry Safety Rules regulating the application of this equipment in explosion hazard zones. 2 Basic specifications 2.1 Basic specifications are detailed in Table 1. Table 1 Parameter name Value SSX BPG/BPGC ZAG HVJB SSXU BPGU/BPGCU ZAGU Ingress protection according to GOST IP66/IP67 IP65/IP66/IP67 IP66/IP67 IP65/IP66/IP67 Electric shock hazard protection class according to GOST I Ambient range, C Standard size (WxHxD, mm) -65 C to +175 C (design without glass) -60 C to +80 C (design with glass) -65 C to +90 C (with silicon seal) -65 C to +175 C (design without glass) -60 C to (design with glass) -20 C to (standard design) (see Table 5) -65 C to +175 C (with silicon seal) -65 C to +90 C (with silicon seal) 2.2 Structure of conventional designation of SSX, SSXU series boxes: SSXX1XX2, S (meaning stainless steel ) material of construction of the housing: 316L (EN ) grade stainless steel (Russian equivalent is 03Х17Н14М3 grade steel according to GOST ). SX series designation; X1 design: if missing, the design is standard, if U, then it is Ex-component; XX2 standard size characterizing value: 45, 64, 66, 0, 0.5, 1, 1.5, 2, 3, 4, 5, 6, 7, 8, C to +180 C (design without glass) -60 C to +90 C (design with glass).3 Values of the maximum dissipation power depending on standard size of SSX series boxes are specified in Table 2. Table 2 dissipation power, W Temperature Temperature class T6 / T85 C class T5 / Temperature class T3 /T200 C T85 C temperatu re +60 C +65 C +80 C +80 C Explosion protection level Ga, Gb, Db (experts (auditor experts)) +175 C 45 (114x114x51) (102x152x63) (152x152x102) (152x229x140/200) (154x274x140/200)
4 Standard size (WxHxD, mm) 1 (234x274x x140/200) 1.5 (306x306x 2 (372x324x 3 (372x448x 4 (372x510x 140/200/300) 5 (510x510x 6 (510x780x 7 (650x950x 8 (800x1250x 225 (2000x2000x x140x200x300) Sheet 3 Series RU No Table 2 breakover Temperature class T6 / T85 C +60 C dissipation power, W Temperature class T5 / T85 C +65 C Temperature class T3 /T200 C +80 C +80 C +175 C Explosion protection level Ga, Gb Explosion protection level Da 45 (114x114x51) (102x152x63) (152x152x102) (152x229x x140/200) ,5 (184x274x x140x200) (234x274x x140/200) ,5 (306x306x (372x324x (372x448x (372x510x (510x510x (510x780x x140/20/300) (experts (auditor experts))
5 Standard size (WxHxD, mm) Table 2 breakover Sheet 4 Series RU No Temperature class T6 / T85 C +60 C dissipation power, W +65 C Temperature class T5 / T85 C +80 C Temperature class T3 /T200 C +80 C +175 C 7 (650x950x (800x1250x minimum of the components is 100 C 2 minimum of the components is 110 C 3 minimum of the components is 200 C 2.4 Structure of conventional designation of BPG/ BPGC, BPGU / BPGCU series boxes: BPGX1X2XX3, where: BPG series designation; X1 material of housing construction: If the sign is missing, - fiberglass reinforced polyester (any colour except black is permissible); C - fiberglass reinforced polyester with admixture of carbon (black colour). X2 - design: if missing, the design is standard, if U, then it is Ex-component; XX3 standard size characterizing value: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 13.5, 14, 15. Standard size (WxHxD) 2.5 Values of the maximum dissipation power depending on standard size of BPG/BPGC series boxes are specified in Table 3. Table 3 dissipation power, W Temperature class Temperature class Temperature class T6 /T85 C T5 /T100 C T4 /T135 C +60 C +65 C +90 C Explosion protection level Ga, Gb, Db 1 (80x75x55) (110x75x55) (160x75x55) (190x75x55) (230x75x55) (122x120x90) (220x120x90) (160x160x90) (260x160x90) (360x160x90) (560x160x90) (255x250x120) (400x250x120) (400x250x120) (400x405x120) (400x405x120) Explosion protection level Da 1 (80x75x55) (110x75x55) (experts (auditor experts))
6 Standard size (WxHxD) Sheet 5 Series RU No Table 3 breakover Temperature class T6 /T85 C dissipation power, W +60 C +65 C Temperature class T5 /T100 C Temperature class T4 /T135 C +90 C 3 (160x75x55) (190x75x55) (230x75x55) (122x120x90) (220x120x90) (160x160x90) (260x160x90) (360x160x90) (560x160x90) (255x250x120) (400x250x120) (400x250x120) (600x250x120) (400x405x120) Structure of conventional designation of ZAG / ZAGU series boxes: ZAGX1XX2, where: ZAG series designation; X1 - design: if missing, the design is standard, if U, then it is Ex-component; XX2 standard size characterizing value: 2, 3, 4, 5, 6, 7, 9, 9/9, 10, 10/9, 11, 12, 13, 15, 16, Values of the maximum dissipation power depending on standard size of ZAG series boxes are specified in Table 4. Table 4. Standard size (WxHxD, mm) Temperature class T6 / T80 C Temperature class T5 / T95 C +70 C dissipation power, W Explosion protection level Ga, Gb, Db Temperature class T4 / T130 C +90 C +105 C Temperature class T3 /T180 C +135 C +150 C 2 (58x64x34) (98x64x34) (150x64x34) (75x80x57) (125x80x57) (175x80x57) (122x120x80) /9 (122x120x90) (220x120x80) /9 (220x120x90) (150x160x90) (260x160x90) (experts (auditor experts))
7 Standard size (WxHxD, mm) Table 4 breakover Sheet 6 Series RU No dissipation power, W Temperature class T6 / T80 C Temperature class T5 / T95 C Temperature class T4 / T130 C Temperature class T3 /T180 C +70 C 13 (360x160x90) (202x230x110) (330x230x110) (120x360x80) Explosion protection level, Da +90 C +105 C +135 C +150 C 2 (58x64x34) (98x64x34) (150x64x34) (75x80x57) (125x80x57) (175x80x57) (122x120x80) /9 (122x120x90) (220x120x80) /9 (220x120x90) (160x160x90) (260x160x90) (360x160x90) (202x230x110) (330x230x110) (120x360x80) Structure of conventional designation of HVJB series boxes: HVJBX1X2(X3 - X4), where: HVJB series designation (High Voltage Junction Box); X1 - standard size characterizing value: 7, 8; X2 maximum quantity of conductors in the circuit: 3, 4; X3 - X4 quantity of connections per phase X3 upper, X4 lower. 2.9 Values of the maximum dissipation power of HVJB series boxes are specified in Table 5. Table 5 Standard size (WxHxD, mm) 7 (650(700)x950x300) Ambient range, C dissipation power, W -20 C to 259 T4 / T70 C -50 C to T4 / T70 C Temperature class in terms of gas / dust -50 C to 259 T150 C (T3) / T70 C (experts (auditor experts))
8 Table 5 breakover Standard size (WxHxD, mm) 8 (800(850)x1250x300) Sheet 7 Series RU No Ambient range, C dissipation power, W Temperature class in terms of gas / dust -20 C to 346 T4 / T70 C -50 C to 173 T4 / T70 C -50 C to 346 T150 C (T3) / T70 C 2.10 Values of maximum dissipation power of HVJB series boxes with peripheral connections are specified in Table 6. Table 6 Ambient range, C dissipation power, W Peripheral connections Main connections -20 C to C to Note: it is inadmissible to establish peripheral connections with HVJB boxes with T150 C class in terms of gas and T110 C class in terms of dust Values of the maximum dissipation power of HVJB series boxes equipped with BPG boxes of standard sizes 6, 7, 8 are specified in Table 7. Table 7 4-Way (4-wire circuit) 3-Way (3-wire circuit) 2-Way (2-wire circuit) Standard size dissipation power, W current, A dissipation power, W current, A dissipation power, W current, A 7 Inadmissible Inadmissible Note: it is inadmissible to connect BPG boxes to HVJB boxes with T150 C class in terms of gas and T110 C class in terms of dust The list of explosion-proof components which can be parts of boxes and which are provided with valid compliance certificates issued by accredited certification authorities and their marking are detailed in Table 8. Table 8 Name and type (model) of associated explosion-proof electrical equipment Explosion Compliance No. (manufacturer, country) protection marking certificate Terminal clamps (terminals) of P, Z, WFF, SAK, SAKK, SAKH, AKZ series (Weidmuller TC RU C-DE. 1 Ex e II Gb U Interface GmbH & Co. KG, Germany) ГБ08.В Terminals of the following types: AGK, AKG, ATEX, DT, EK, EMSTB, EMSTBA, EMSTBV, FKC, FKIC, FRONT, G, GFKC, GKDS, GMSTB, GMSTBV, GMVSTBR, GMVSTBW, IAK, IC, ICV, MBK, MBKKB, MKKDS, MKKDSH, MK3DSH, MK3DSMH, MSB, MSDB, MSLKG, MSTB, MSTBA, MSTBV, MSTBVA, MT, MTKD, TC RU C-DE. 2 ExeII U MUT, MVSTBR, MVSTBW, MXK, PT, PTO, PTTB, QTC, QTCS, QTCU, QTTCB, ГБ05.В RBO, RT, RTO, SLK, SMSTB, SPT, SSK, ST, STS, STTB, STTBS, UHSK, UK, UKH, ULSKG, UT, UTTB, UXKK, VDFK, VIOK, ZFKDS, ZFKDSA (Phoenix Contact GmbH & Co. KG, Germany) Devices for distribution of electricity for in explosive environments: WAGO Ex e II U TC RU C-DE. 3 trademark electric connectors Ex ia IIC U AT15.В (WAGO Kontakttechnik GmbH & Co. KG, Germany) 3 Description of design and explosion protection means 3.1 SSX / SSXU boxes are a housing with a cap which is attached using screws (four screws for standard sizes 45, 64, 66, 0.5, 1, 1.5, 2, 3, 4, 5; eight screws for standard sizes 6. 7, 8). Box caps of standard sizes 0, 0.5, 1, 1.5, 2, 3, 4, 5, 6, 7, 8, 225 are equipped with hinges and a slot for lock tag. A silicone gasket is installed between the housing and the cap. Terminal clamps are installed inside the box on a DIN rail / DIN rails. The maximum possible quantity of DIN rails is five for 7 and 8 standard size boxes; four for 5 and 6 standard size boxes, three for 1.5, 2, 3, 4 size boxes, two for 0.5 and 1 standard size boxes, and one for other size boxes. Cable inlets and/or stopping boxes are installed on side surfaces of the housing. There is an internal and external earthing terminal. Eyes for vertical attachment of boxes to the wall are welded to the rear surface of the housing. SSX series boxes designed for use in the range of -50 C to +80 C can be manufactured with a sight glass in the cap. BPG / BPGC / BPGU / BPGCU series boxes are a housing with a cap which is attached using recessed screws (four screws for standard sizes 1, 2, 3, 4, 6, 7, 8, 10, 12, 13, 13.6, 15; six screws for standard sizes 5, 11, 14). A silicone gasket is installed between the housing and the cap. A copper earthing bus connected to the external and internal earthing terminal can be optionally installed inside the housing. The terminal clamps are installed on a DIN rail / DIN rails inside the box. The maximum possible (experts (auditor experts))
9 Sheet 8 Series RU No quantity of DIN rails is three for boxes of standard size 15, two for boxes of standard sizes 12, 13, 13.5, 14 and one for other size boxes. Cable inlets and/or stopping boxes are installed on side surfaces of the housing. The built-in components of BPG / BPGC / BPGU / BPGCU series boxes are equipped with insulation with limit 100 C minimum for class T6 / T85 C and 130 C minimum (or they are ceramics) for T4 /T100 C. ZAG / ZAGU series boxes are a housing with a cap which is attached using four recessed screws. The housing and the cap are cast in aluminium alloy ASil2 (its Russian equivalent is casting alloy AK7 according to GOST ). A silicone gasket is installed between the housing and the cap. Terminal clamps are installed inside the box on a DIN rail / DIN rails (except standard sizes 2, 3 and 4 where terminals are attached on the inside of the housing). The maximum possible quantity of DIN rails is three for boxes of standard sizes 15, 16, 21, two for boxes of standard sizes 12, 13, and one for boxes of standard sizes 6, 7, 8, 9, 9/9, 10. Cable inlets and/or stopping boxes are installed on side surfaces of the housing. There is an internal and external earthing terminal. ZAG / ZAGU series boxes designed for use in the range of s from -60 C to +90 C can be manufactured with a 4 mm thick sight glass in the cap. HVJB box design is a metal housing with internal guides and with a hinged cap (300 mm deep boxes SX7 and SX8) made of 316L (EN ) stainless steel (its Russian equivalent is 03Х17Н14М3 steel according to GOST ). A silicone gasket is installed between the housing and the cap. Up to four copper buses can be installed inside the housing for conductor connection. Buses on insulators can provide connection of two cables per phase, one cable per phase, or combination depending on the layout. The cables are connected using corrugated lugs which are clamped between the buses. There is an internal and external earthing terminal. Eyes for vertical attachment are welded to the rear surface of the housing. 3.2 Explosion protection of SSX series boxes with explosion protection marking 1Ex e IIC T6 Gb X / Ex tb IIIC T85 C Db X, 1Ex e IIC T5 Gb X / Ex tb IIIC T100 C Db X, 1Ex e IIC T3 Gb X / Ex tb IIIC T200 C Db X of BPG series boxes with explosion protection marking 1Ex e IIC T6 T4 Gb X / Ex tb IIIC T85 C T100 C Db X, BPGC series boxes with explosion protection marking 1Ex e IIC T6 T4 Gb / Ex tb IIIC T85 C T100 C Db, ZAG series boxes with explosion protection marking 1 Ex e IIC T6 T3 Gb Ex tb IIIC T85 C T180 C Db and HVJB series boxes is provided by explosion protection type enhanced protection e according to GOST R IEC , dust ignition protection using t shells according to GOST R IEC , use of certified components and by designing them in accordance with the requirements of GOST R IEC Explosion protection of SSX boxes with explosion marking 0Ex ia IIC T6 T3 Ga / Ex ta IIIC T85 C T200 C Da, BPG series boxes with explosion protection marking 0Ex ia IIC T6 T5 Ga X / Ex ta IIIC T85 C T100 C Da X, BPGC series boxes with explosion protection marking 0Ex ia IIC T6 T5 Ga X / Ex ta IIIC T85 C T100 C Da X and ZAG series boxes with explosion protection marking 0Ex ia IIC T6 T3 Ga X/Ex ta IIIC T85 C T180 C Da X is provided by explosion protection types intrinsically safe electrical circuit ia according to GOST R IEC , dust ignition protection using t shells according to GOST R IEC , use of certified components and by designing them in accordance with the requirements of GOST R IEC Explosion protection of SSX series boxes with explosion marking 1Ex ib T6 T3 Gb / Ex tb IIIC T85 C T200 C Db, BPG series boxes with explosion protection marking 1Ex ib IIC T6 T4 Gb X / Ex tb IIIC T85 C T100 C Db and ZAG series boxes with explosion protection marking 1Ex ib IIC T6 T3 Gb Ex tb IIIC T85 C T180 C Db is provided by explosion protection type intrinsically safe electrical circuit ib according to GOST R IEC , dust ignition protection using t shells according to GOST R IEC , use of certified components and by designing them in accordance with the requirements of GOST R IEC Explosion protection of SSXU, BPGU / BPGCU, ZAGU with explosion protection marking Ex e IIC Gb U is provided by explosion protection type enhanced protection e according to GOST R IEC , use of certified components and by designing them in accordance with the requirements of GOST R IEC Explosion protection of SSXU, BPGU / BPGCU, ZAGU with explosion protection marking Ex ia IIC Ga U is provided by explosion protection type intrinsically safe electrical circuit ia according to GOST R IEC , use of certified components and by designing them in accordance with the requirements of GOST R IEC Explosion protection of SSXU, BPGU / BPGCU, ZAGU with explosion protection marking Ex ib IIC Gb U is provided by explosion protection type intrinsically safe electrical circuit ib according to GOST R IEC , use of certified components and by designing them in accordance with the requirements of GOST R IEC Special conditions of safe use X Symbol X in marking of SSX, BPG / BPGC, ZAG, HVJB series boxes indicates their safe use as follows: - the boxes shall be complete with cable inlets and/or stopping boxes and breathing valves (if required), explosion-proof, with explosion protection level, gas subgroup, ingress protection IP and range no worse than those specified in the Table on form No and Table 1. Special conditions of safe use of SSXU, BPGU /BPGCU, ZAGU series boxes are as follows: - the boxes shall be complete with cable inlets and/or stopping boxes and breathing valves (if required), explosion-proof, with explosion protection level, gas subgroup, ingress protection IP and range no worse than those specified in the Table on form No and Table 1. Symbol X in marking of BPG series boxes indicates their safe use as follows: - the boxes shall be installed in locations protected against air jets with dust particles and against any other external actions contributing to accumulation of static electricity on the housings; - wipe housings with a clean cloth maintenance. (experts (auditor experts))
10 Sheet 9 Series RU No Symbol X in marking of BPG / BPGC series boxes with explosion protection marking 0Ex ia IIC T6 T4 Ga X / Ex ta IIIC T85 C T100 C Da X and ZAG series boxes with explosion protection marking 0Ex ia IIC T6 T3 Ga X / Ex ta IIIC T85 C T180 C Da X indicates their safe use as follows: - when the boxes are used in class 20 explosive dusty environments, the equipment power supply shall be designed for possible short-circuit of no more than 10 ka. Symbol X in marking of ZAG series boxes indicates their safe use as follows: - installation and the boxes shall be protected against impacts which may cause frictional sparks. Special conditions of safe use of BPGU series boxes are as follows: - the boxes shall be installed in locations protected against air jets with dust particles and against any other external actions contributing to accumulation of static electricity on the housings; - wipe housings with a clean cloth maintenance. Special conditions of safe use of BPGU / BPGCU, ZAGU series boxes with explosion protection marking Ex ia IIC Ga U are as follows: - the equipment power supply shall be designed for possible short-circuit of no more than 10 ka. Special conditions of safe use of ZAGU series boxes are as follows: - installation and the boxes shall be protected against impacts which may cause frictional sparks. The manufacturer shall ensure transfer of the requirements to special conditions of safe use to the customer alongside with any other necessary information. 3.4 Amendments to the coordinated drawings and changes to the product design are only possible upon coordination with Certification Authority Research and Development Centre TECHNOPROGRESS. The manufacturer s responsibility covers all equipment to be certified and the component equipment for which there are valid certificates (hereafter referred to as certificates) allowing its use in explosive zones, therefore the manufacturer shall: - check the validity of certificates for the components listed in Table 8 and preclude installation of components without valid certificates; - inform Certification Authority Research and Development Centre TECHNOPROGRESS about any prolongation or receipt of new certificates for the components and about any design changes which might influence the explosion protection of the end product. 4 Marking applied on the equipment includes the following data: - name of the manufacturer and its registered trademark; - `name of the product, equipment type designation; - explosion protection marking; - warning labels: WARNING OPEN AFTER DISCONNECTION FROM THE MAINS, Cable inlet may exceed the by 30 C ; - manufacture date and serial number of the product according to manufacturer s numbering system; - name or symbol of certification authority and the compliance certificate number; - special explosion protection symbol according to appendix 2 to Technical Regulation of Customs Union 012/2011; - unified symbol of the product circulation on the market of Customs Union member states, according to item 1, article 7 of Technical Regulation of Customs Union 012/2011; - any other data which shall be provided by the manufacturer if it is required by technical documentation. (experts (auditor experts))
CERTIFICATE OF CONFORMITY No. TC RU С- DE.AB72.B.02315 Series RU No. 0492042 CERTIFICATION AUTHORITIES Certification authority of products of "Scientific and Technical Center "Techno-standard Limited Liability
More informationFlameproof Manual Call Points Series MCP
> Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied
More informationIECEx Certificate of Conformity
Certificate of Conformity: IECEx SIR 09.0111 http://iecex.iec.ch/iecex/iecexweb.nsf/fc034777969a786bc1256d42005bd791/f076962... Page 1 of 3 22/01/2010 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL
More informationIndoor/outdoor resistance thermometer Model TR60
Temperature Indoor/outdoor resistance thermometer Model TR60 WIKA data sheet TE 60.60 for further approvals see page 2 Applications Ambient temperature measurement Air-conditioned rooms, cold-storage rooms,
More informationCUSTOMS UNION Translation CERTIFICATE OF CONFORMITY No. RU -D.08..01489 Series RU No. 0356093 CERTIFICATION BODY FOR EXPLOSION-PROOF EQUIPMENT AT CLOSED J.-ST. CO. "TESTING CENTRE FOR TECHNICAL MEASUREMENTS,
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx UL 08.0012X issue No.:5
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationFlameproof Manual Call Points Series MCP
> Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied
More informationExplosion-proof Immersion Heater Type D-8660
Explosion-proof Immersion Heater Type D-8660 Sinus Jevi has developed explosionproof Ex de heating equipment, for hazardous area. The flame-proof (d) enclosures have been designed for non save areas to
More informationCCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.
Ex d CCAC - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66 Stainless steel bolts Polyester coating External earth screw Grub screws for opening lid External earth screw
More informationTemperature Measurement Transmitters for field mounting
Siemens AG 07 Overview Application The SITRANS TF can be used everywhere where temperatures need to be measured under particularly harsh conditions. For that reasons users from all industries have opted
More informationOPTIBAR DP 7060 Supplementary Instructions
OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,
More informationFlameproof Manual Call Points
Operating instructions Additional languages www.r-stahl.com CS & Clifford & Snell Contents General Information.... Manufacturer.... Information regarding the operating instructions.... Further documents....
More informationIndustrial & Hazardous Area Electrical Equipment
Industrial & azardous Area Electrical Equipment 2017 Abtech has been supplying electrical connection products to hazardous and industrial markets since the 1970 s. Our range includes hazardous area lighting,
More informationExplosion Proof Manual Call Points Series MCP
> Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied
More informationzonex enclosures hazardous locations
zonex enclosures Equipment PROTECTION hazardous locations ZONEX Enclosures An expanded offering of Hinge- and Screw-cover Enclosures for hazardous locations. ATEX directive 94/9/EC and IECEX certified
More informationEN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures
EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures HDL-3-EX* Complete and ready to install Heat Detector with Ex-certified Box, Cable gland and wiring
More informationofficial distributor of Newson Gale Ltd.
Continuous Ground Loop Monitoring with visual indication. The precision and reliability of the provides enhanced safety and security by continuously testing the connection of the clamp to the container
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:2 Status: Current Certificate history:
More informationEJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67
Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket
More informationElectrical Installations Design, Selection, Erection and Inspection
IECEx International Conference 2018 Jakarta, Indonesia Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2018 Jakarta, Indonesia Peter Thurnherr thuba Ltd.,
More informationEarth-Rite II PLUS Static Earthing System
READ MANUAL BEFORE COMMENCING WITH INSTALLATION EN Earth-Rite II PLUS Static Earthing System P1 PLUS - DC Supply Installation & Operating Instructions The safety of any system incorporating the equipment
More informationManual Power relay SR853
Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death
More informationTYPE APPROVAL CERTIFICATE
TYPE APPROVAL CERTIFICATE Certificate No: E-14378 This is to certify: That the Pilot Device with type designation(s) Pilot device Issued to BARTEC GmbH BAD MERGENTHEIM, Germany is found to comply with
More informationIECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Certificate history: Status:
More informationInductive slot sensor
0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output
More informationBoth enclosures provide an IP 66 degree of ingress protection and are suitable for both indoor and outdoor installation.
Continuous Ground Loop Monitoring with visual indication. The precision and reliability of the provides enhanced safety and security by continuously testing the connection of the clamp to the container
More informationSafety instructions VEGAPULS 64
Safety instructions Intrinsic safety "i" 4 20 ma/hart - two-wire Document ID: 53001 Contents 1 Area of applicability... 3 2 Important specification in the type code... 3 3 Different ignition protection
More informationCertificate of Compliance
Certificate of Compliance Certificate: 2557738 Master Contract: 256526 Issued to: Bartec Varnost d.o.o Cesta 9 avgusta 59 Zagorje ob Savi, 1410 Slovenia Attention: Janez Gajski The products listed below
More informationSafety instructions VEGABAR 81, 82, 83, 86, 87
C US Safety instructions VEGABAR 81, 82, 83, 86, 87 Dust ignition protection CSA 70015745 Document ID: 52267 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 4 4 Installation
More informationEx LED light fittings
About us TEP Ex is a regional leader in manufacturing of explosion-protected electrical equipment. Through continuous development of new products and markets, modernization of technology and investment
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4
More informationOilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor
Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000
More informationAiro Wireless Intrinsically Safe White Paper. Written By: David Schmitt
Airo Wireless Intrinsically Safe White Paper Written By: David Schmitt Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection certification for safe operation with electronic
More informationICV 2,5/ 6-G-5,08. Extract from the online catalog. Order No.:
Extract from the online catalog ICV 2,5/ 6-G-5,08 Order No.: 1785984 The figure shows a 10-position version of the product Header, Nominal current: 12 A, Nom. voltage: 320 V, Pitch: 5.08 mm, Number of
More informationMultiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55
www.stahl.de > Pre-wi ready-to-use multi-signalling unit > Corrosion resistant > Suitable for offshore / onshore harsh environments > Incorporates the FX15 GRP beacon YA90 for visual audible notification
More informationIntegrated Solutions Low Voltage Systems
Integrated Solutions Low Voltage Systems 612 Contents Energy Distribution Overview Module Technology 8146 614 Overview Flameproof Enclosures 8220 614 Overview Flameproof Enclosures 8261 614 Overview CUBEx
More informationBeamex. Calibration White Paper. Calibration in hazardous areas
Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous
More informationIECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection
IECEx International Conference 2017 Shanghai, China Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2017 Peter Thurnherr Shanghai thuba Electric Co. Ltd.,
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...
More informationOperating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans
Operating Instructions Edition 11/2005 Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA sitrans Introduction 1 General safety instructions 2 SITRANS Process monitoring Ex-barrier
More informationRosemount 752 FOUNDATION Fieldbus Remote Indicator
Rosemount 752 FOUNDATION Fieldbus Remote Indicator Product Data Sheet 00813-0100-4377, Rev FA Two-wire segment powered device Displays up to eight values Link Master Capability Optional PID, Characterizer,
More informationIECEx Certificate of Conformity
Page 1 of 4 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate
More informationGRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S
www.stahl.de > Corrosion resistant omnidirectional high output sounder > Integrated Ex d enclosure > Extreme temperature range > 3 stage alarm with independant tone selection for V DC systems > IP66 IP67
More informationAnnubar Flowmeter Series
Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA
More informationUL HAZARDOUS LOCATIONS SERVICES
UL HAZARDOUS LOCATIONS SERVICES The international preference in hazardous locations certification for over 100 years ul.com/hazloc Explosive Gas Atmospheres Class I Division S Includes flammable gases,
More informationOperating Manual Distribution box
Distribution box Operation manual Distribution box 27-5452-... Type 27-5452-... EN 1/12 EN 2/12 1. Product description The distribution boxes Type 27-5452-... are used for connections and distribution
More informationPESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard
Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard Persons concerned: Experienced professional electricians as per EU Directive
More informationHazardous Areas - EXPLOSIONPROOF SOLENOIDS
Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas
More informationOperating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA
Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 4.1 Electrical limit switch... 4
More informationSET Installation and Operating Instructions. Level switch for one sensor
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel.: +358 29 006 260 Fax: +358 29 006 1260 7.11.2013 Internet: www.labkotec.fi 1/14 SET-1000 Level switch for one sensor Copyright 2013 Labkotec Oy
More informationCertificate of Compliance
FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296
More informationFixed Gas Detection System/Meridian CERTIFICATION
The marking shall include 2 Wire Aluminum Transmitter 3/4 Wire Aluminum Transmitter 2 Wire Stainless Steel Transmitter (PN: 096-3521) (PN: 096-3522) (PN: 096-3525) Ex db [ia Ga] IIC T4 Gb Ex db [ia Ga]
More informationSOLUZIONI PER ATMOSFERA ESPLOSIVA
catalogo ATEX 2015 SOLUZIONI PER ATMOSFERA ESPLOSIVA ATEX catalogue book 2016 SOLUTIONS FOR EXPLOSIVE ATMOSPHERES Since 1904 In 1904 PALAZZOLI began its activity in Brescia when electrical energy was first
More informationBeamex Calibration White Paper. Calibration in hazardous areas
Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous
More informationSeat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.
ATEX SOLUTIONS In order to apply a single level for health and safety requirements and to overcome barriers of trade within Europe, national regulations for explosion prevention were harmonized in 1975
More informationOfficine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0
Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:
More informationOperating instructions for HAWE devices
Operating instructions for HAWE devices For designated use in potentially explosive atmospheres B- 04-2016-2.1 by HAWE Hydraulik SE. The forwarding and reproduction of this document, as well as the use
More informationGuide for hazardous areas
Guide for hazardous areas 1 Hazardous areas definitions 2 Gas and dust s 3 Temperature classifications 4 Common flammable gases, vapours and dust types 5 Protection concepts ATEX and IECEx 6 Protection
More informationCertificate of Compliance
FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The
More informationGTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres
Z31.0.XX.6C-11 Temperature Probe for potentially explosive atmospheres (Measuring ranges from -200 to +900 C) Operating Manual GTF 103-Ex 0081 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße
More informationSafety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS
Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS 10.0008 Ex td A20, A20/21, A20/22, A21 IP66 T 0044 37675 Contents 1 Area of applicability 3 2 General information 3 2.1 Zone 20 instruments
More informationDSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor
Product ID Type # Product # Drawing # DSF 1210.00 SHV Ex-atex (2m) 374Z-05066 110428F1 DSF 1210.00 SHV Ex-atex (5m) 374Z-05176 110428F1 DSF 1210.00 SHV Ex-atex (10m) 374Z-05590 110428F1 DSF 1410.00 SHV
More informationFan Heaters Type VLEx
Fan Heaters Type VLEx Fan Heater type VLEx has been designed for Explosion Proof industrial applications. Our Fan Heaters are characterized mainly by their quality, both in used materials and design. Liquids
More informationCirculation heaters for ATEX/IECEx hazardous areas or in non-atex version
for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI500EN 09/2017
More informationTemperature measurement with SITRANS T siemens.com/processinstrumentation
Top values in precision and reliability Temperature measurement with SITRANS T siemens.com/processinstrumentation Temperatures firmly under control Top process quality and efficiency are key factors for
More informationImmersion heaters for ATEX/IECEx hazardous areas or in non-atex version
for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI100EN 09/2017
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm
More informationInspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN
Inspection Light LED Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3 Conformity
More informationATM Lighting sp. z o.o
INSTALLATION AND MAINTENANCE MANUAL FOR EXPLOSIONPROOF LIGHT FITTING EXL210LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk,
More informationOilSET Installation and Operating Instructions. Oil Separator Alarm Device
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 18.11.2010 Internet: www.labkotec.fi 1/10 OilSET-1000 Oil Separator Alarm Device Copyright 2010 Labkotec
More informationARGENTA ATEX For potentially explosive atmospheres. ARGENTA ATEX Technical Specifications Wall-mounting cabinets. ARGENTA ATEX Certifications
For potentially explosive atmospheres IDE presents its ATEX certified product range, specially intended for potentially explosive atmospheres, where the degree of protection and strength must be maximised.
More informationOPTIBAR P 1010/2010 C Supplementary instructions
OPTIBAR P 1010/2010 C Supplementary instructions Pressure transmitter Equipment category II 1G / Ga, II 1D / Da in protection type intrinsic safety Exi KROHNE CONTENTS OPTIBAR P 1010/2010 C 1 Safety instructions
More informationProduct manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands
Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these instructions
More informationRosemount 752 Fieldbus Remote Indicator
Product Data Sheet Rosemount 752 Rosemount 752 Fieldbus Remote Indicator ROSEMOUNT 752 DELIVERS: Two-wire segment powered device Displays up to 8 values Link Master Capability Optional PID, Characterizer,
More informationPRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres
PRODUCT OVERVIEW Light fittings, boxes & custom built control panels for explosive atmospheres LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones
More informationExplanations of Applications in Hazardous Areas
facts & DATA Explanations of Applications in Hazardous Areas Technical information The information regarding cross sectional area and connection types pertains to unprepared wires without ferrules! Ferrules
More informationExplosion Protection Enclosure with integrated measuring system
TR - ECE - BA - GB - 0099-08 02/21/2018 Translation of the original manual Explosion Protection Enclosure with integrated measuring system Explosion Protection Enclosure - Types _ADV75 _ADH75 ADH75 ADV75
More informationGuide to Hazardous Location Approvals:
Selection Guide Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches Introduction There are many considerations when selecting a switch to be used in hazardous areas. In addition
More informationRosemount 2088, 2090P, and 2090F Pressure Transmitters
April 2013 Rosemount 2088 and 2090 Rosemount 2088, 2090P, and 2090F Pressure Transmitters with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol Start Step 1: Mount the Transmitter Step 2: Set the Jumpers
More informationSwitches compliant with ATEX directive
Switches compliant with ATEX directive General Catalogue - Technical concepts page Position switches FD / FL series page 9 / Category Zone EPL Approvals 2G Gb Mb II 2G Ex ia IIC T6 Gb I Ex ia I Mb Product
More informationOPTIWAVE X500 Supplementary Instructions
OPTIWAVE X500 Supplementary Instructions OPTIWAVE 3500 C OPTIWAVE 6500 C OPTIWAVE 7500 C Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE X500 1 General safety information 4 1.1
More informationDICTATOR Hold-Open Systems for Hazardous Areas
DICTATOR for Hazardous Areas Products to be used in hazardous areas obviously have to meet special demands. The European ATEX directives (first the EN 94/9/EG and then the directive 2014/34/ EU) brought
More informationSmartLine. RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December Technical Information.
SmartLine Technical Information RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December 2015 Introduction The Honeywell RMA803 is a Foundation Fieldbus remote indicator suitable
More informationIntrinsically safe acoustic emission equipment opens the door to permanent monitoring applications in the oil and gas industry
18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Intrinsically safe acoustic emission equipment opens the door to permanent monitoring applications in the oil and
More informationDuct heaters for ATEX/IECEx hazardous areas or in non-atex version
for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI200EN 09/2017
More informationE DATA SHEET
ISO 9001 UK-VK SWITCHING UNIT UK-VK rev.10 UK-VK rev.11 UK-VK rev.1 UK-VK rev.13 UK-VK rev.14 UK-VK rev.15 4641.00 E DATA SHEET 1 MAIN SPECIFICATIONS 1.1 General 1.1.1 This datasheet is applicable to the
More informationAtmosphere. Introduction. explosion when exposed to a source of ignition. and IEC standards as follows:
ATEX enclosures Enclosures for explosive atmospheres Introduction PB500061-26 PB500060-47 PB500059-52 Oxygen Heat Chain reaction Fuel Explosive atmosphere Potentially explosive atmospheres: important information
More informationmanual addendum DELPHI Ex
manual addendum DELPHI Ex II 2G Ex eb IIC T4 Gb II 2D Ex tb IIIC T135 C IP65 Db Tamb=-20 +40 C Reference list: Norm (last issue) Title Dir. 2014/34/UE EN 60079-31 EN60079-0 EN60079-7 Equipment and Protective
More informationHOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper
HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper How Limit and Basic Switches Can Stop Machines from Going Boom White Paper sensing.honeywell.com 2 Abstract In hazardous
More informationRFM Series RFM-ISR Barrier. Installation Manual
PSM INSTRUMENTATION LTD RFM Series RFM-ISR Barrier Installation Manual Issue A Burrell Road Industrial Estate Haywards Heath, West Sussex RH16 1TW, UK Tel: +44 (0)1444 410040 Fax: +44 (0)1444 410121 Http://www.psm-sensors.co.uk
More informationZENITH P Series Increased Safety Enclosures and Terminal Boxes for Applications in Hazardous Environments
ZENITH P Series Increased Safety Enclosures and Terminal Boxes for Applications in Hazardous Environments ZENITH P Series Increased Safety Ex e Enclosures / Terminal Boxes > SCAME PARRE S.p.A. Established
More informationA guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.
A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here Introduction Potentially Explosive Atmospheres exist where there is a risk
More informationRosemount 248 Temperature Transmitter
Product Data Sheet November 2013 00813-0100-4825, Rev KA Rosemount 248 Temperature Transmitter Basic temperature transmitter offers a reliable solution for temperature monitoring points transmitter design
More informationARRAN LED LED FLOODLIGHT. Standard Specification. Features
ARRAN LED LED FLOODLIGHT The Arran LED floodlight range is low energy with an instant on output and up to 130,000 maintenance free hours. Specifically designed for applications where moisture, dirt or
More informationHazardous Location Heaters. Thermostat INSTRUCTION MANUAL
Hazardous Location Heaters Thermostat INSTRUCTION MANUAL Rev. K 2018 nvent P/N 89115890 TABLE OF CONTENTS Warranty and Return Policy...2 Application...3 Control Accuracy...3 Technical Data...3 Design Data...3
More informationEVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation
EVL-B Shock-resistant tempered glass - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation costs - Suitable for GAS category IIC LED
More informationRADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION
Special Safety Instruction en RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION Contents TankRadar Pro European ATEX Directive Information............................... 2 ATEX marking and Ex Certification
More informationZENITH P Series Increased Safety Enclosures and Terminal Boxes for Applications in Hazardous Environments
ZENITH P Series Increased Safety Enclosures and Terminal Boxes for Applications in Hazardous Environments ZENITH P Series Increased Safety Ex e Enclosures / Terminal Boxes > SCAME PARRE S.p.A. Established
More informationATEX catalogue book SOLUTIONS FOR EXPLOSIVE ATMOSPHERES
ATEX catalogue book 20172018 SOLUTIONS FOR EXPLOSIVE ATMOSPHERES Since 1904 In 1904 PALAZZOLI began its activity in Brescia when electrical energy was first used in the industry. The Company is specialized
More information