4, INCH STAINLESS STEEL SUBMERSmLE PUMPS, MOTORS, CONTROL BOXES, & ACCESSQRIES 1-10
|
|
- Kristian Hawkins
- 5 years ago
- Views:
Transcription
1 FRESHWATER CATALOG - TABLE OF CONTENTS PAGE 1 SUBMERSIBLE WATER PUMPS 4, INCH STAINLESS STEEL SUBMERSmLE PUMPS, MOTORS, CONTROL BOXES, & ACCESSQRIES 1-10 SUBMERSmLE EFFLUENT PUMP. SPRINKLER SPRAY PUMP FOR AEROBIC SySTEM INCH STAINLESS STEEL SUBMERSffiLE PUMPS, MOTORS, AND CONfROL BOXES CHEMICAL FEED PUMPS CHEIvfICAL FEED PillvIPS. DIAPHRAM & PERISTALIC WATER WELL JET PUMPS "MS" DESIGN SERIES PUMPS. VERTICAL. MULTI-STAGE JET PUMPS. 1-2 HORSEPOWER..27 "SSJ" DESIGN SERIES PillvIPS. VERTICAL SINGLE-STAGE JET PUMPS.%- 1 HORSEPOWER "SL" DESIGN SERIES PUMPS. HORIZONTALCONVERTIBLE SINGLE-STAGEJET PUMPS. Y2-1 HORSEPOWER 29, BOOSTER PUMPS "SN" DESIGN SERIES PillvIPS. CAST IRON HORIZONTAL CLOSE COUPLED BOOSTER PUMPS. Y2- % HORSEPOWER "HN" DESIGN SERIES PUMPS. CAST IRON HORIZONTAL. CLOSE COUPLED BOOSTER PUMPS. 1 HORSEPOWER PAGE C
2 FRESHWATER CATALOG- TABLE OF CONTENTS PAGE 2 BOOSTER PUMPS "PN' DESIGN SERIES PUMPS. PLASTIC HORIZONTAL CLOSE COUPLED BOOSTER PUMPS. ~ -1 HORSEPOWER 34 "PL" DESIGN SERIES PUMPS. PLASTIC HORIZONTAL CLOSE COUPLED BOOSTER PUMPS.~ -1 ~HORSEPOWER STAINLESS STEEL CENTRIFUGAL PUMPS. HORIZONTAL CLOSE COUPLED BOOSTER PUMPS. ~ - 15 HORSEPOWER "J" AND "JB" DESIGN SERIES PUMPS. CAST IRON HORIZONTAL CLOSE COUPLED BOOSTER PUMPS. ~ -2 ~ HORSEPO'WE-R.' "IThtfS" DESIGN SERIES PQ1v1PS. CAST IRON HORIZONTAL MULTI-STAGEBOOSTERPUMPS.%- 1 ~ HORSEPOWER "CJIOI" DESIGN SERIES PUMPS. CAST IRON HORIZONTAL MULTI-STAGE BOOSTER PUMPS. %-3 HORSEPOWER "TC" AND "FC" DESIGN SERIES PUMPS. STAINLESSSTEEL HORIZONTALCLOSE COUPLEDPUMPS.%- 15 HP ~ TYPE ''B'' DESIGN SERIES PUMPS. CAST IRON HORIZONTAL. CLOSE COUPLED BOOSTER PUMPS HP "DPC" DESIGN SERIES PUMPS. SELF PRIMING DESIGN. CAST IRON HORIZONTAL CLOSE COUPLED PUMPS. ~ HP 69 PAGE D
3 PAGE 3 BOOSTER PUMPS "CJ" DESIGN SERIES PUMPS. SELF PRIMING DESIGN SERIES OF PUMPS. STAINLESS STEEL HORIZONTAL BOOSTER PUMPS. 1 & 1 Y2HORSEPOWER "SPC" DESIGN SERIES PUMPS. SELF PRIMING DESIGN SERIES OF PUMPS. STAINLESS STEEL HORIZONTAL BOOSTER PUMPS. % & 1 Y2HORSEPOWER I "DSS4HG" DESIGN SERIES PUMPS. SELF PRIMING DESIGN SERIES OF PUMPS. CAST IRON HORIZONTAL CLOSE COUPLED BOOSTER PUMP. 2 HORSEPOWER ''PD'' DESIGN SERIES PUMPS. SELF PRIMING DESIGN SERIES OF PUMPS. PLASTIC HORIZONTAL CLOSE COUPLED BOOSTER PUMPS. 1-2 ~ HORSEPOWER "D" DESIGN SERIES PUMPS. SELF PRIMING DESIGN SERIES OF PUMPS. CAST IRON HORIZONTAL CLOSE COUPLED BOOSTER PUMPS. 1-5 HORSEPOWER CAST IRON BASKET STRAINERS. 2" THRU 8" "HH" & "HL" DESIGN SERIES PUMPS. SELF PRIMING DESIGN SERIES OF PUMPS. CAST IRON CLOSE COUPLED BOOSTER PUMPS HORSEPOWER SWIMMING POOL PUMPS "P2R" DESIGN SERIES PUMPS. SELF PRIMING DESIGN SERIES OF PUMPS. PLASTIC SWIMMING POOL PUMPS. Y2-1 Y2HORSEPOWER. 92 "CSP" & "CCSP" DESIGN SERIES PUMPS~SELF PRIMING DESIGN SERIES 0F PUMPS. CAST IRON SWIMMING POOL PUMPS. 7 Y2-20 HORSEPOWER PAGE E
4 PAGE 4 HIGH PRESSURE BOOSTER PUMPS "lips" DESIGN SERIES PIDvIPS. STAINLESS STEEL HIGH PRESSURE BOOSTER PUMPS. HORIZONTAL MULTI-STAGE UNITS. Y2-3 HORSEPOWER "lit" & "IN-LINE" DESIGN SERIES PillvfPS. HIGH PRESSURE BOOSTER PUMPS. 2-'40 HORSEPOWER IOO-lOl "BVM" DESIGN SERIES PUMPS. VERTICAL MULTI- STAGE BOOSTER PillvfPS. STAINLESS STEEL & CAST IRON UNITS. Y2-40 HORSEPOWER SPECIAL DESIGN SERIES PUMPS "ED"& "B" DESIGN SERIES PUMPS. GASOLINEDRIVEN CENTRIFUGAL PUMPS HORSEPOWER ~ STEEL CONVENTIONAL STYLE PRESSURE TANKS & ACCESSORIES GALVANIZED STEEL PRESSURE TANKS GALLON RATED TO 75 PSI GALLON..RATED TO 150 PSI NON-ASME CODE TANKS STEEL EPOXY LINED PRESSURE TANKS GALLON RATED TO 75 PSI NON-ASME CODE TANKS STEEL HORIZONTAL CONVENTIONAL PRESSURE TANKS GALLON..RATED TO 75 PSI AS~ CODE TANK.146 "WHITEWATER" TANK. AIR COMPRESSORS INCLUDING SIGHT GLASS TUBE AND VALVES PAGE F
5 FRES"WATER CATALOG-TABLE OF CONTENTS PAGE 5 POLYETHYLENE WATER STORAGE & ACCESSORIES TANKS P9LYETHYLENE WATER STORAGETANKS & ACCESSORIES.50-10,000 GALLONS 153 BLADDER STYLE PRESSURE TANKS STEEL BLADDER STYLE PRESSURE TANKS GALLONS---RATED TO 100 PSI NON-ASME CODE STEEL BLADDER STYLE PRESSURE TANKS GALLONS---RATED TO 125 PSI NON-AS:ME CODE FIBERWOUND BLADDER STYLE PRESSURE TANKS GALLONS---RATED TO 100 PSI... NON-ASME CODE.1' STEEL BLADDER STYLE PRESSURE TANKS GALLONS---RATED' TO 150 PSI NON-ASME CODE STEEL BLADDER STYLE PRESSURE TANKS GALLONS--RATED TO 125 PSI ASME CODE. TANK WATER METERS WATER METERS AND OTHER ACCESSORIES ACCESSORIES C~ORINE 'fest KIT 175 ELECTRICAL METERS AND OTHER ACCESSORIES 176 WRENCHES, VISES, AND OTHER ACCESSORIES PIPE ELEVATORS AND FISIDNG TOOLS..179 PAGE G
6 PAGE 6 ACCESSORIES PVC S.ADDLE TEES. 180 WATER WELL LEVEL TEST EQUIPMENT 181 WATER WELL JETS, ADAPTERS & OTHER ACCESSORIES CAPACITORS AND BEARINGS 184 PRESSURE SWITCHES, STARTERS, SNUBBERS & ETC WELL SEALS, SNIFTER VALVES, & ACCESSORIES DRAWDOWN WELL SEALS & FLOW CONTROL VALVES 190 FLOAT BALLS & OTHER ACCESSORIES :..~191 SUBMERSffiLE PUMP ELECTRICAL CABLE 192 SPLICE KITS & PIPE REPAIR CLAMPS 193 BRONZE, PLASTIC, STAINLESS STEEL & CAST IRON FOOT VALVES AND CHECK VALVES PRESSURE TYPE AIR VENT & AIR RELEASE VALVE AIR RELEASES & AIR VOLUME CONTROLS 203 CUP LEA'TlffiRS SUCTION & DISCHARGE HOSE AND ACCESSORIES PRESSURE AND VACUUM GAUGES ~ ORNAMENTAL WINDMILLS AND HAND Pu.MPS PAGE H
7 PAGE 7 ACCESSORIES WINDMILLS,HAND PilldPS, & ACCESSORIES BRASS, STAINLESSSTEEL,PLASTIC, & CAST IRON GATE VALVES, BALL VALVES, & C.I. Y STRAINERS CAST IRON COMPANIONFLANGES & STYLE # 38 PRESSURE PIPE REPAIR COUPLINGS.224 BRASS RELIEF VALVES & FLIP-N-FLOATVALVES GALVANIZED PIPE FITI1NGS & PIPE NIPPLES ELEC'fRIC MOTORS PVC PIPE & GALVANIZED PIPE & ACCESSORIES PVC SLOTI'ED WELL SCREENS. PVC WRAPPED ON PIPE WELL SCREENS STAINLESS STEEL WELL SCREENS WELL SCREEN ACCESSORIES DRILLING MUD& ADDITIVES WATER WELL SCREEN CLEANINGACIDS CHLORINETABLETS & 10% LIQUID CHLORINE SPIN DOWN WATER FILTERS CARTRIDGE STYLE WATER FILTERS DELUXE UNDER-COUNTER TASTE & ODOR WATER FILTER REVERSE OSMOSIS WATER FILTRATION SYSTEM RATED FOR DRINKING WATER SYSTEM\. RATED UP TO 16 GALLONS PER DAY PAGE I
Arch Feeder: Installation Manual
Arch Feeder: Installation Manual Model #A300N Arch Chemicals, Inc. 1200 Lower River Road, P.O. Box 800 Charleston, TN 37310-0800 Product Stewardship MAKING THE WORLD A BETTER PLACE Arch is committed to
More informationSERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS
40 Third Street Piqua, Ohio 45356-0603 www.pumpagents.com PumpAgents.com - Click here for Pricing/Ordering SERIES: WT SECTION 4C PAGE ISSUED /04 REPLACES /03 SELF-PRIMING CENTRIFUGAL PUMPS For Water and
More informationSERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS
40 Third Street Piqua, Ohio 4556-060 www.pumpagents.com PumpAgents.com - Click here for Pricing/Ordering SERIES: WT SECTION 4C PAGE ISSUED /04 REPLACES /0 SELF-PRIMING CENTRIFUGAL PUMPS For Water and Other.00
More informationPOULTRY MARKET CATALOG
POULTRY MARKET CATALOG FW0134 0518 Supersedes 0714 Evaporative Cooling Pumps: 1-1/2 or 2 in. discharge Centrifugal Booster Pumps Pressure Booster Pumps Engineered Poultry Pumping Systems One year limited
More informationSERIES: WPT SELF-PRIMING CENTRIFUGAL PUMPS
40 Third Street Piqua, Ohio 4556-060 www.pumpagents.com PumpAgents.com - Click here for Pricing/Ordering SERIES: WPT SECTION 4C PAGE 5 ISSUED /0 REPLACES /0 SELF-PRIMING CENTRIFUGAL PUMPS For Perchlorethylene
More informationSERIES: WPT SELF-PRIMING CENTRIFUGAL PUMPS
40 Third Street Piqua, Ohio 4556-060 www.pumpagents.com PumpAgents.com - Click here for Pricing/Ordering SERIES: WPT SECTION 4C PAGE 5 ISSUED /0 REPLACES /0 SELF-PRIMING CENTRIFUGAL PUMPS For Perchlorethylene
More informationC. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.
SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More informationCondensate Boiler Feed Water Make-Up
1144 Utica Ave, Brooklyn, NY 1103 July 0 New Catalogue Release Bulletin 9C.01 Low Inlet Condensate Receiver (7 from floor) Close Grained Cast Iron Simplex and Duplex Design To 0,000 SQ-Ft EDR Pump Capacity
More informationChoosing the Right Pump
Choosing the Right Pump Pumps are used to move fluid from one destination to another. They come in many different shapes, sizes, and operated by either electric motor, engine, by hand or solar power. They
More informationSilhouette. Feedwater Heater. Boiler Feedwater
Roth Roth Low Low Silhouette Silhouette TRAY DEAERATORS Boiler Boiler Feedwater Feedwater Heater Heater Capacities Capacities to to 50,000 50,000 lb/hr lb/hr Model RDTV-150-5-1-2 vertical tray type deaerator
More informationFM 517 San Leon, TX Toll Free: Office: (281) Fax: (281)
www.rbmosherco.com 5902 FM 517 San Leon, TX 77539 Toll Free: 1-800-444-2207 Office: (281) 339-3382 Fax: (281) 559-1152 E-mail: sales@rbmosherco.com R.B. MOSHER CO. has been in business since 1986, providing
More informationVent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI
Vent-Rite BULLETIN VCRV AUGUST 0 GUARDIAN Plus Cast Iron And Steel Receivers Simplex, Duplex, Triplex And Quadruplex Units Pump Capacities To 0 GPM Discharge Pressure To 7 PSI 87 Dewey Avenue Benton Harbor,
More informationINSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION
INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / 27-009, 27-010, 27-015, 27-020 IMPORTANT INFORMATION UNATHORIZED CHANGES OR ALTERATIONS TO ANY LINCOLN PORTABLE VACUUM SYSTEM WILL AUTOMATICALLY
More informationSECTION STEAM CONDENSATE PUMPS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 22 23 STEAM CONDENSATE PUMPS SPEC WRITER NOTES: 1. Delete between // ---- // if not applicable to project. Also delete any other item or paragraph not applicable
More informationTramp Oil. Removal Equipment Equipment designed for removing oil from water based fluids ERIEZ. ...Only from Eriez. Tramp Oil. Removal Equipment:
...Only from Eriez FB-200B Tramp Oil Removal Equipment: Oil Skimmer Oil Skimmer Jr. Coalescer Tank-Side Coalescer Portable Coalescer Portable Jr. Centrifuge Portable ERIEZ Tramp Oil Removal Equipment Equipment
More informationLine Overview Catalog
Line Overview atalog FW1053 0315 Supersedes 0213 4, 6 & 8 Submersible Pumps, Pump Motors, ontrols, Jet Pumps, entrifugal Pumps, Specialty Pumps and Water onditioning 4 Submersible Pumps 1/2 to 7 1/2 HP
More informationSECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.
SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15410 - Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections. 1.02 SUBMITTALS A. Submit properly identified
More informationEVMSU - Vertical Multistage Pumps. Product Catalog
EVMSU - Vertical Multistage Pumps Product Catalog www.pumpsebara.com Built like a Kata a A Katana is a traditional Japanese sword made with distinctive, longstanding expertise started in 300 A.D. Katana
More informationSECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS
PART 1 GENERAL 1.01 SECTION INCLUDES A. Pipe and Pipe Fittings. B. Air compressor. C. Air receiver and accessories. D. Aftercooler. E. Refrigerated air dryer. F. Pressure reducing station. 1.02 RELATED
More informationOn top of your casing, you use a pitless well cap. The cap has a conduit opening on it to
So you want to install a submersible pump in your water well. If you collect the proper information about your well, there should be no reason that you could not install your own submersible water pump.
More information1 P a g e. G4 Counter Top OPERATION MANUAL
1 P a g e G4 Counter Top OPERATION MANUAL Table of Contents Introduction. 3 Receiving....4 Description Model G3 & G4...5/6 Water Production Flow Chart...7 Positioning the Cooler...8 Water Cooler Connections..9
More informationPumps SELECTION OF A PUMP
Pumps SELECTION OF A PUMP A water system needs to move the water produced from the source to its customers. In almost all cases in Minnesota, the source is at a lower elevation than the user so the water
More informationHID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service
HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service What you will learn Introduction Installation Operation Maintenance Take It Apart Diagnostics HID Ice Maker-Dispensers HID models
More informationDUKE UNIVERSITY CONSTRUCTION STANDARDS
1 22 40 00 Plumbing Fixtures 1. General A. Definitions 1. Section includes a. Water closets and urinals b. Lavatories, sinks, and service sinks c. Electric water coolers, drinking fountains, d. Showers
More informationLABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS
SECTION 22 20 00 LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements",
More informationHoffman Specialty Pump Products
Condensate Units Boiler Feed Units Vacuum Heating Units Hoffman Specialty Pump Products S-0692C INDEX Condensate Return Units Series WC Series WCS Series SCC Boiler Feed Units Stock Watchman Condensate
More informationOWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION
ClearChoice Economy Under Sink Drinking Water System OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION Congratulations on the purchase of your ClearChoice
More informationSTOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.
STOP Power supply required Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-742-5044, 7:30 a.m. - 5 p.m., EST, Monday - Friday. 115 volts
More informationCommercial, Residential & Institutional Pumps, Tanks, & Accessories
Taco International Commercial, Residential & Institutional Pumps, Tanks, & Accessories Taco Catalog # : 300-6.0 Supersedes: 300-3.5 9/11/06 Effective Date: 03/21/07 Printed in USA Pumps FI Frame Mounted
More informationTable of Contents. List of Figures
1 P a g e Table of Contents Introduction. 3 Receiving....4 Description Model G3 & G4...5/6 Water Production Flow Chart...7 Positioning the Cooler...8 Water Cooler Connections..9 Feed Water Connection....10
More informationREVERSE OSMOSIS SYSTEMS
REVERSE OSMOSIS SYSTEMS TABLE OF CONTENTS R.O. SYSTEM DESCRIPTION... 2 R.O. EQUIPMENT INSTALLATION...3 R.O. SYSTEM CHECK-OUT PROCEDURE... 4 R.O. UNIT TURN ON PROCEDURE...5 R.O. UNIT RATING.. 6 R.O. BAY
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE PUMP REVIEW Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved; AC-Approved w/comments;
More informationD. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationHydrotherapy Jets (Remote Water Quality System)
Page 1 of 6 Parts List (_) - 50 Roll of Flex PVC pipe 1-3/4 HP Circulating Centrifugal Pump 1 25 Roll of Flex PVC pipe 4-1 1 / 2 " Tees 2-1 1 / 2 " Ball Valves 2 - Female slip couplers 4-1/2" 90 degree
More informationUpdate In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL
Section 23 20 00 FLUID SYSTEMS EQUIPMENT PART 1 GENERAL 1. CHILLERS Page 23 20 00-1 A. Provide chiller packages with centrifugal compressors, or screw compressors, and water cooled condensers. B. Design
More informationTECHNICAL. Series 18. Pump Packages
TECHNICAL S Y S T E M S Series 18 Pump Packages Series 18 Pump Packages Standard Features Close-coupled, end-suction, centrifugal pumps Mounted and wired pump starters Hand-Off-Auto switch for each pump
More informationOWNERS GUIDE TO INSTALLATION AND OPERATION END SUCTION CENTRIFUGAL PUMPS
OWNERS GUIDE TO INSTALLATION AND OPERATION END SUCTION CENTRIFUGAL PUMPS IL00 Figure - CJ0, EL0 Series IL0 Figure - CJ0, EL0 Series Drain Plug READ THESE INSTRUCTIONS CAREFULLY Read these installation
More informationSECTION WATER HEATERS
SECTION 15457 WATER HEATERS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: A complete hot water generating system with necessary accessories as indicated on Construction Documents, as specified, and
More informationRay's Well Testing Service Inc Shadowhill Dr, Santa Rosa Ca Phone Fax Lic#
Ray's Well Testing Service Inc. 4031 Shadowhill Dr, Santa Rosa Ca 95404 Phone 707 823 3191 Fax 707 317 0057 Lic# 903708 CUSTOMER INFORMATION REPORT #: 7249 - By: Cody Monday DATE OF TEST: 5/5/2015 CUSTOMER
More information/ / Take the technological step into MODERN Condensate Handling Equipment for steam systems MANUFACTURED IN AMERICA with craftsmanship and quality.
Take the technological step into MODERN Condensate Handling Equipment for steam systems MANUFACTURED IN AMERICA with craftsmanship and quality. Condensate Return Units / Shippensburg / / Fill Tanks / Boiler
More informationLC Series - Light Commercial Pump Station Installation and Operation Manual
LC Series - Light Commercial Pump Station Installation and Operation Manual Please keep this manual with the pump station Content Rain Bird LC Series Overview... Safety Instruction... Operation... 3 Pump
More informationParts Washers, Water Pumps, special applications
Parts Washers, Water Pumps, special applications 147 Parts Washers Storm King Automotive and Industrial Parts Washers Simple Operation Fill the Storm King cleaning basket with parts, close the door, parts
More informationSAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION
Quality Products & Value Packages Residential Solutions FIRE PROTECTION COMFORTSUSTAINABILITYCONTROL PRESSURE REGULATORS TRENCH DRAINSHVAC SYSTEMS SAFETY ANTI-SCALE SYSTEMS HEATING & COOLING CONTROLS PLUMBING
More informationHVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS
230500 HVAC BASIC MATERIAL AND METHODS PART 1 GENERAL 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS A. Section 230000 Basic HVAC Requirements B. Section 230523 Valves C. Section 230510 Chilled
More informationIndustrial. Solutions brands you trust. Product Overview
Industrial Solutions brands you trust. Product Overview Industrial Pump Applications Crane & Systems design s the most efficient and economical pumps to serve the large diversity of industrial applications
More informationTOOLS & MISCELLANEOUS
TOOLS & MISCELLANEOUS 01-5095 251189 Sillcock Tee Handle, For 16 Broach Splined Stem, Fits Most Outside Hose Valves. 052151010056 01-5223 251199 4 Way Stem Key, Fits Square Stems 1/4, 9/32, 5/16, & 11/32.
More informationSTEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationMARLOW PUMPS RECIRCULATION
End suction centrifugal pump line available in both close coupled and frame mounted configurations allow users to meet exactly most flow conditions on commercial pool and waterpark applications. Features
More informationWATER-SUPPLY WELL PITLESS ADAPTER OR PITLESS UNIT, AND WELDED OR THREADED FITTING.
4725.4850 WATER-SUPPLY WELL PITLESS ADAPTER OR PITLESS UNIT, AND WELDED OR THREADED FITTING. Subpart 1. Pitless adapter or pitless unit. Except as provided in subpart 2, a connection to a casing of a water-supply
More information.2 Section Waste Management and Disposal..5 Section Performance Verification of Mechanical Piping Systems.
Issued 2006/08/01 Section 15181 Hydronic Specialties Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal.3 Section 01780
More informationModel F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers
Bulletin 060 Rev. A Bulletin 060 Rev. A Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers Features 1. Available in the following configurations: Pendent with standard escutcheon
More informationDNJ SERIES PUMPS END SUCTION CLOSE COUPLED
DNJ SERIES PUMPS END SUCTION CLOSE COUPLED DNJ SERIES PUMPS These are close coupled with standard JM solids shaft ball bearing motors specially designed for pump applications in accordance with standards
More informationFUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED
FUEL OIL DAY TANKS SST Series - Engineering Submittal SST Series - Advanced Line Day Tanks Construction: UL 142 aboveground steel tank all seam welded, square, atmospheric tank of heavy gauge steel with
More informationHALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps
Safety Important Safety Instructions SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during installation, operation, and maintenance of the product. Save this
More information6-30 Vertical Deep Well. Close Coupled Vertical Turbine Submersible Turbine. Pump Type. Application. Description. Materials
A GORMAN-RUPP COMPANY Pump Type 6-30 Vertical Deep Well Close Coupled Vertical Turbine 6-30 Submersible Turbine Application Agricultural Irrigation, Municipal Water Supply, Industrial Process Water, Golf
More informationIntelligent Variable Speed Pump
IntelliFlo VS+SVRS Intelligent Variable Speed Pump The ONLY way to comply with new federal anti-body entrapment standards and save money There s simply no better way to add a Safety Vacuum Release System
More informationHOT WATER BOILER ( MBH)
GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER (25-200 MBH) Repair PARTS MANUAL P/N 24000523, Rev. C [09/08] TABLE OF CONTENTS I. Circulator Pumps (Optional)...2 II. Burner Assembly...3 III. Boiler
More informationA. This Section includes the following domestic water piping specialties:
SECTION 221119 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
More informationUF424 and UN324. Technical Service
UF424 and UN324 Technical Service Technical Service 1-800-533-6006 Check out the new mobile ready website www.scotsman-ice.com/service Technical Service Virtual Business Card What you will learn Introduction
More informationSELF-CLEANING EXTRACTORS
NEW IN 2019! SPRINKLER FOR SELF-CLEANING EXTRACTORS SELF-CLEANING EXTRACTORS OUR EXTRACTORS ARE NOW AVAILABLE WITH A SPRINKLER FOR SELF-CLEANING! THIS OPTION MAY ALSO BE INSTALLED ON YOUR EXISTING EXTRACTORS!
More informationOwner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service
Owner's Manual (00 Gallon Lawn Service Skid Sprayer) Technical Specifications. Horsepower Recoil Start Engine Roller Cast Iron Pump 0 Gallons Per Minute at 0 PSI Pressure Gauge-Adjustable Pressure Range
More informationDomestic Pump Condensate Transfer Equipment
Bulletin S-944L Domestic Pump Condensate Transfer Equipment CONDENSATE RETURN UNITS BOILER FEED UNITS LOW NPSH PUMPS VACUUM HEATING UNITS INDUSTRIAL VACUUM UNITS www.domesticpump.com Condensate Return
More informationPRODUCTS THAT CONSERVE, REPAIR AND SAVE!
please specify sale sale code code when when ordering PBW92 PBW93 valid valid thru thru 5//5 3// - 5/30/5-3/3/ TAP INTO SAVINGS! PRODUCTS THAT CONSERVE, REPAIR AND SAVE! DON'T FORGET... EPA s Fix a Leak
More informationAmerican Hydro Systems
Caution: Read all instructions carefully before beginning the installation Siphoning Systems Keep this manual handy for future reference Owner s Manual INSTALLATION OPERATION PARTS LIST DOSAGE Our Siphoning
More informationUNIT PANELS 6/25/ :15:30 AM Page 2 of 27
MF56 1 UNIT PANELS 2 REFRIGERANT SYSTEM AIR COOLED 3 REFRIGERANT SYSTEM WATER COOLED 4 WATER SYSTEM AND INSULATIONS - UP TO S.N. 23384 5 WATER SYSTEM AND INSULATIONS - FROM S.N. 23385 TO S.N. 24159 6 WATER
More informationPhiloWilke Partnership Addendum No. 2 A/E Project No April 2016
SECTION 23 21 23 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions and Division 01 Specification Sections, apply to this Section.
More informationG315/6 Cast Iron Boiler
Engineering Submittal Sheet Boiler Overview LISTED Engineering Specifications There shall be provided and installed G315-6 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing
More informationMission Critical. Fuel Supply Systems
Fuel Supply Systems Insight Onsite Fuel Supply Systems Page 2 Simplex Mission Critical Fuel Supply Systems are comprehensive, integrated, project-matched fuel management systems for diesel and turbine
More informationSECTION STEAM CONDENSATE PUMPS
SECTION 23 22 23 - STEAM CONDENSATE PUMPS PART I - GENERAL 1.1 SECTION INCLUDES A. Steam Condensate Return Units, Gravity Return Type 1. Receiver 2. Pumps 3. Control Panel 4. Accessories Note to PSC: Although
More informationSECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 Codes and Standards: A. Plumbing Code Compliance: Comply with applicable portions of National Standard Plumbing Code pertaining to selection and installation of Plumbing materials
More informationLAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.
ELECTRIC WATER HEATER SCHEDULE DESIGNATION MODEL MANUFACTURER STORAGE RECOVERY TEMPERATURE LEAVING ELECTRICAL CHARACTERISTICS REMARKS/SPECIAL INSTRUCTIONS NUMBER GALLONS RATE RISE WATER K.W. VOLTAGE PHASE
More informationWayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No
SECTION 213113 - ELECTRIC-DRIVE, CENTRIFUGAL FIRE PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationWilo IL Vertical Split-Coupled Inline Pumps
Wilo IL Vertical Split-Coupled Inline Pumps Vertical Inline Split-Coupled, Single Stage Pumps March, 2013 Marcos D. Roimicher, Product Manager BS Market Segment, Product Management Department 120-08-002-0313
More informationCMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.
CMA Dishmachines 1700 Knott Avenue Garden Grove, CA 981 Toll Free: 1- (800) 8-617 Fax: 1- (71) 89-11 Service Replacement Parts Undercounter High Temperature Dishwasher Model: UC6e M Machine Serial No.
More informationB. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationIMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.
Eagle Pump Owners Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents SECTION I. INSTALLATION... 2 SECTION II. OPERATION & MAINTENANCE... 2 SECTION
More informationInstallation and Operation Manual
How To Install, Operate and Maintain Your Reverse Osmosis System FILTER CARTRIDGE CONFIGURATION MAY BE SUBJECT TO CHANGE. 475 PRO SERIES 475BP PRO SERIES INSTALLERS: PLEASE READ ALL INSTRUCTIONS BEFORE
More informationHYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler
SECTION 15181 - HYDRONIC SPECIALTIES PART 1 - GENERAL 1.1 SECTION INCLUDES A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler B. Expansion tanks C. Pump accessories 1.2 RELATED SECTIONS
More informationElectric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features
Electric Pumps Introduction W4100, W4200 & W4300 Condensate Pumps Watson McDaniel s Condensate Return and Boiler Feed Pumps are equipped with Cast Iron bodies and Bronze Impellers. The pump receiver tanks
More informationSECTION PLUMBING EQUIPMENT
PART 1 GENERAL 1.01 SECTION INCLUDES A. Water heaters. B. Packaged water heating systems. C. Domestic water heat exchangers. D. Water storage tanks. E. Water softeners. F. Reverse osmosis equipment. G.
More informationDomestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.
Cast Iron Receivers: For years of dependable service; warranted for 20 years from date of shipment against failure due to corrosion. Each Receiver comes standard with Inlet connection, an overflow and
More information5. CONDENSATE PUMPS/UNITS
INDEX Condensate Systems/Pumps GENERAL INFORMATION BURKS PARTS I&O MANUALS. CONDENSATE PUMPS/UNITS PUMP TYPES: GV GV6 USA: (937) 778-8947 Canada: (90) 47-6223 International: (937) 61-398 A 7/1 Condensate
More informationCleaning Equipment. Table of Contents. Fuel Injection Pump Cleaning Pressure Washers Blasting Equipment Miscellaneous...
Table of Contents Fuel Injection Pump Cleaning... 9-1 Pressure Washers... 9-2 Blasting Equipment... 9-37 Miscellaneous... 9-45 Table of Contents Fuel Injection Pump Cleaning 6V-6188 Cleaning Tray Warranty:
More informationG315/5 Cast Iron Boiler
Engineering Submittal Sheet Boiler Overview LISTED Engineering Specifications There shall be provided and installed G315-5 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing
More informationPackaged Steam Fired Water Heater
MODEL ST Packaged Steam Fired Water Heater Utilizes Steam To Heat Domestic Water, Semi-Instantaneous or Storage Type Heaters Features Reliable Packaged System Only high grade materials used in construction
More informationSpecialty Products. Gutter Guards. Pine Guard Gutter Protection System
Specialty Products Gutter Guards Pine Guard Gutter Protection System Must be installed in conjunction with on new gutters only 18-Gauge expanded powder coated metal base (will not rust) Keep Pine needles
More information4-1 1 / 2 " Tees / 2 " hole saw w/ 1/4" drill bit / 2 " Male slip plugs
Section 1: Parts List 1-50 Flex PVC pipe 2-1 1 / 2 " Ball Valves 4-1/2" 90 degree elbows 4 - Lengths of 1/2" PVC 4 - Jet bodies 4 - Jet nozzles 4 - Female slip/female slip unions 2 - Female slip/fpt union
More informationResidential Pump Fundamentals
Residential Pump Fundamentals Goulds Pumps and the ITT Engineered Blocks symbol are registered trademarks and tradenames of ITT Industries. 2001 Goulds Pumps Effective August, 2001 www.goulds.com Sources
More informationmith Mills 4500A Smith Mills 4500A 4500A-3R OIL, GAS OR COMBINATION GAS/OIL COMMERCIAL BOILER/BURNER CAST IRON
Mills 00A mith Mills 00A Smith CAST IRON OIL, GAS OR COMBITION GAS/OIL COMMERCIAL BOILER/BURNER 00AR STEAM GAUGE OPERATING CONTROL MODULATING CONTROL HI LIMIT PRESSURE CONTROL 0" STEAM DRUM TEST COCK /"
More informationWallace & Tiernan Gas Feed Systems V2000 Chlorinator
Wallace & Tiernan Gas Feed Systems V2000 Chlorinator Introduction Siemens Water Technologies chlorination equipment has the benefit of 100 years of experience in gas feed technology. V2000 chlorinators
More informationResearch Design Quality Value Service Experience
2017 INDEX ACCUMULATORS...27 ACCUMULATOR - DRIERS...27 CAPILLARY ASSEMBLIES Strainer...30 Strainer-Drier...29 CONDENSERS (WATER COOLED) Coaxial...19 Shell & Coil...18 DRIERS Big R...28 Junior...29 Filter...25
More informationTRIMAX ASIA ENGINEERING & CONSTRUCTION (PG U )
TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG0176866-U ) FIRE PROTECTION EQUIPMENTS PARTS CATALOGUE TRIMAX ASIA ENGINEERING & CONSTRUCTION No. 24, Jalan Pantai, 12000 Butterworth, Penang, Malaysia. Fax: +6
More informationmith Mills Smith Mills 6500A 6500A-4 OIL OR GAS CAST IRON BOILER/BURNER CAST IRON
mith Mills Mills 00A OIL OR GAS CAST IRON BOILER/BURNER Smith CAST IRON 00A- - Gas I=B=R Ratings: Gross Output 7,19 to 1, FRONT VIEW WITH INDUS COMB BURNER SIDE VIEW WITH INDUS COMB BURNER SIDE VIEW -
More informationRoto-Jet I & II Tube Cleaning Systems
Roto-Jet I & II Tube Cleaning Systems Tube Size Tube Section Deposit Thickness of Deposit Deposit Flush 0.312 to 2.000 Straight Soft, guy, Light (7.9 to 50.8) ID Curved or organic Medium Dry Elliott Tool
More information.005 ATMOSPHERIC DEAERATOR
.005 ATMOSPHERIC DEAERATOR OCTOBER 1, 2007 GENERAL DESCRIPTION The Sellers atmospheric.005 deaerators condition make-up water and condensate returns to convert them into more desirable boiler feedwater.
More informationFLANGE-MOUNT CENTRIFUGAL PUMPS
40 Third Street Piqua, Ohio 4556-060 www.pumpagents.com PumpAgents.com - Click here for Pricing/Ordering SERIES GV6 SECTION E PAGE ISSUED /0 REPLACES /0 FLANGE-MOUNT CENTRIFUGAL PUMPS Idel for OEM applications
More informationModel AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description
Worldwide Contacts www.tyco-fire.com Model AV--00 Alarm Valve With and Without Model RC- Retard Chamber European Conformity Valve Trim General Description The TYCO Model AV--00 Alarm Valves DN, DN0, DN0,
More informationTRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999
TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO. 8801469 EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999 THE MILK COOLING SYSTEMS SPECIALISTS TM FRE-HEATER Part No. 8801469 Table
More informationWinterization of Piping in HOA Buildings and Water Features Cedar Falls HOA User Guide CF-002 (UPDATED as of April 14, 2018)
Winterization of Piping in HOA Buildings and Water Features Cedar Falls HOA User Guide CF-002 (UPDATED as of April 14, 2018) 1.0 Description: Each fall protective measures must be taken prior to the first
More informationJ-PRO-24 Pump Chlorinator. Installation & Start-Up Guide
J-PRO-24 Pump Chlorinator Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance, your system will be providing treated water
More information