1 Food & Beverage Cabinet

2 Copyright June 2017 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of Future Products Group Ltd. Part No Rev. P June Fusion, Food & Beverage Cabinet

3 Table of Contents INTRODUCTION... 7 Welcome... 7 Future Products Group (FPG)... 7 Guidance and Help... 7 Warranty... 7 Warranty Period... 7 Liability Exceptions... 8 Specific Exclusions... 8 Assessment... 8 Time Limit... 8 Caution... 8 OPERATION... 9 Cabinet Layout... 9 Fusion Series Cabinets... 9 Lighting... 9 Refrigeration Equipment... 9 Heated Section... 9 Thermometers... 9 Controls Mains Power Refrigerated Section Controls Heated Section Controls Preparation Power Supply Heating Refrigeration Defrost Cycle Load Cabinet Shelves Positions Shelf Loading Operational Routines After Hours Cleaning Refrigeration Condensate Warning- Flammable Products Equipment Disposal Specialist Disposal TROUBLE SHOOTING Dixell XR40CX Alarm Responses Probe Faults HA Alarm HA2 Alarm IN-FUS-HC Future Products Group

4 CLEANING Cautions Power Water Exterior Painted and Metal Surfaces Interior Condensate Tray Shelves & Trays Cabinet Well Cooling Fins Temperature Probe Drain Holes Routines Schedules Condenser Radiator ACR Tray Warning Inspection Correction INSTALLATION Regulations Compliance with Local Requirements Operational Safety Preparation Unpacking Cabinet Preparation Power Supply Earthing Equipotential Bonding Location Ventilation Access Draughts Level Site Part No Rev. P June Fusion, Food & Beverage Cabinet

5 SERVICING Mains Lead Lead Replacement Lighting Protection Caution LED Strips LED Power Supplies Heating Heating Elements Element Replacement Temperature Control Thermometer Battery Replacement Control Gear Ventilation Fan Refrigeration Caution Access to Control Gear etc Access to Condensing Unit etc Condenser Ventilation Controller Adjustment Probe Locations Thermometer Fan Deck Condensate Disposal ACR Fault Finding Guide Temperature Regulator XR40CX XR40CX Compressor Control XR40CX Defrost Control XR40CX Key Functions XR40CX LED Functions XR40CX Min & Max Recorded Temperature XR40CX Reset Max/Min Temperature Memory XR40CX Display the Set-point XR40CX Change the Set-point XR40CX Start a Manual Defrost XR40CX Programming Mode XR40CX The Hidden Menu XR40CX Locking and Unlocking the Keyboard FPG Settings XR40CX Hot Key XR40CX Alarm Signals XR40CX Alarm Recovery XR40CX Other Messages XR40CX Connections IN-FUS-HC Future Products Group

6 SPECIFICATIONS Mechanical Electrical Cabinet Performance Refrigerated Section Performance Controller Settings Application Specific Settings XR40CX Settings Compliance Safety Aspects Hazardous Substances Improvements On-going Development ELECTRICAL CIRCUIT DIAGRAM Model: IN-FUS-HC10-A SPARE PARTS Cabinet Serial Number MECHANICAL DRAWINGS IN-FUS-HC10-A Part No Rev. P June Fusion, Food & Beverage Cabinet

7 Welcome INTRODUCTION - INTRODUCTION Future Products Group (FPG) Welcome to the world of FPG! Our products are designed and engineered to give you the optimal performance that you deserve with innovative visual merchandising appeal. We are confident that you will be delighted with your state of the art door-less bottle cooler, and that it will become a valued appliance in your store. Guidance and Help Any new appliance can seem very complex and confusing at first glance. To ensure you receive the utmost benefit from your new door-less bottle cooler, there are two things you can do. Before operating the cabinet, please read the instruction book carefully and follow its recommendations. The time taken will be well spent. These instructions both general and technical tell you how to operate and look after your door-less bottle cooler so that you can receive the full benefits that this cabinet has to offer. These instructions cannot, however, cover all eventualities. If you are unsure of any aspect of the installation, instructions or performance of your cabinet, contact your dealer promptly or contact us via to support@fpgworld.com. Warranty - INTRODUCTION Warranty Period Future Products Group Limited warrants, to the original purchaser of an FPG manufactured door-less bottle cooler that for ONE YEAR (12 months), from the date of purchase, any defect in workmanship or material resulting in the product malfunctioning while under correct use will be rectified. Liability under this warranty is limited to replacing or repairing a part, without charge. Continued on next page IN-FUS-HC Future Products Group

8 Warranty cont. - INTRODUCTION Liability Exceptions Liability under this warranty does not include: Any loss, or damage or expenses directly or indirectly arising from use or inability to use the product or from any other cause. Any part of the cabinet which has been subject to misuse, neglect, alteration, incorrect installation, accident, or damage caused by transportation, use of abrasive chemicals, flooding, fire or acts of God. Damage, resulting from failure to have the cabinet regularly serviced every three months by a refrigeration engineer. NB: You will be required to provide copies of service records in the event of compressor failure. Any damage or malfunction resulting from the use of non-fpg supplied spare parts. Specific Exclusions The following are specifically excluded from warranty: Breakage of glass or plastic components or the replacement of LED lighting strips or gaskets. Maladjustment of the electronic refrigeration controller, by an unqualified person. Routine compressor / radiator cleaning. Failure to re-assemble the cabinet correctly after cleaning. Fair wear and tear. Assessment The liability under this warranty is dependent on an assessment by FPG, to determine the defect in workmanship or materials. Time Limit FPG does not guarantee that any service to be performed under this warranty will be carried out within any particular time limit. Caution No warranty claim will be accepted unless authorised by FPG prior to commencement of service. Part No Rev. P June Fusion, Food & Beverage Cabinet

9 OPERATION Cabinet Layout - OPERATION Fusion Series Cabinets The Fusion Series cabinets are open fronted with closed backs. The upper section of the cabinet is heated and the lower section is refrigerated. Although the combined cabinet is constructed as a single unit, each half is electrically independent, with its own power supply cable and plug. Lighting Each half of the cabinet is fitted with high efficiency LED lighting as standard. The lighting in the cold section is independently controlled, but the lighting in the heated section is on when the heating is turned on. Refrigeration Equipment The refrigeration equipment is located in the base of the cabinet. The cabinet has openings to allow adequate ventilation to ensure efficient performance. Articles which could restrict air flow must NOT be placed against the cabinet. Heated Section Heat is provided by radiant elements, above the shelves, and the lower shelf is directly heated. The control for the heated section is on the back of the cabinet. A fan circulates air to cool the pelmet, and this must not be obstructed. Thermometers Thermometers are located on the left side, below the heated section and below the return-air grill of the refrigerated section. These indicate the operating temperatures of the heated and refrigerated sections of the cabinet. IN-FUS-HC Future Products Group

10 Controls - OPERATION Mains Power Mains power is independently supplied to each section of the cabinet. The upper heated section has a readily accessible mains switch on the left of the pelmet, which controls both heating and lighting. The refrigerated section has a safety mains isolation switch behind the front louver panel, but will normally be controlled from the supply socket. The air circulation and condenser fans will operate as soon as the power is turned on, but there is a separate switch for the lights, on the left of the upper shelf space. Refrigerated Section Controls Apart from the light switch, there are no operator control switches on the refrigerated section. It is fully operational as soon as it is connected to a mains power point. The control gear is located in the base of the cabinet. The controller has indicator displays and programming buttons. A safety mains isolator switch is provided for servicing. A miniature circuit breaker protects the lighting and low power devices against overload. Heated Section Controls The mains switch controls both heating and lighting. The thermostat for the heated section is on the back of the cabinet. Part No Rev. P June Fusion, Food & Beverage Cabinet

11 Preparation - OPERATION Power Supply Ensure that power is connected to both cabinet sections. Heating Use the power switch on the front left of the cabinet to turn on the heating. The lighting in this section will come on whenever the heating is on. Refrigeration The compressor and cabinet fans will run as soon as power is connected. Use the light switch to control the illumination of the refrigerated section. As the compressor runs, the cabinet temperature will begin to fall. The temperature controller is pre-set to maintain products in a chilled state, and should not need adjustment. Defrost Cycle The refrigeration system will automatically defrost periodically. By sensing the temperature of the cooling fins, the timing and duration of the defrost periods is optimised and has minimal effect on product temperature. Load Cabinet When the appropriate section has reached its operating temperature, load the cabinet with pre-heated and pre-chilled product. Hot products must be pre-heated before loading. Shelves Positions The shelf positions are factory set to achieve correct temperature distribution. Consult FPG if product sizes require shelves to be moved. Ticketing can be inserted along the front of each shelf. Shelf Loading The maximum loading of any shelf must not exceed 15kg of evenly distributed products. IN-FUS-HC Future Products Group

12 Operational Routines - OPERATION After Hours Products should be removed from the heated section after hours. This section of the cabinet can then be switched off, to conserve power and enable cleaning. If the refrigerated section is left running, turn the lighting off to save power. Cleaning Since the cabinet needs to be switched off during cleaning operations, it is best to clean it at the end of the working day. The cabinet will then have time to resume its normal operation, before customers are next expected. Refrigeration Condensate Condensate from the evaporator cooling coils drains into a boil off tray, located under the right hand side of the cabinet. The element is controlled by a water detection system, to conserve energy use. The boil off system copes with the condensed water formed under normal operating conditions. However, as the cabinet is open fronted, the amount of condensate is affected by atmospheric conditions. If the cabinet is located in an un-controlled atmosphere, it is possible that in periods of high humidity, there could be more condensate collected than the boil off system can remove. This could result in temporary water spillage onto the floor. Warning- Flammable Products Do not store explosive substances, such as aerosol cans with a flammable propellant, in this appliance. Equipment Disposal - OPERATION Specialist Disposal Specialist disposal procedures are required for the safe removal of refrigerant gasses and potentially flammable foam materials. Pentane, Dimethyl Ether, Isobutene, Butane and Propane may be present. Part No Rev. P June Fusion, Food & Beverage Cabinet

13 TROUBLE SHOOTING FAULT POSSIBLE CAUSE REMEDY Heated section does not operate Heated section temperature incorrect Refrigerated section does not operate/start Refrigerated section is not cold enough Cabinet lights not working Water on floor Refrigerated section circulation fan rattling The mains switch is off, circuit breaker or fuses are off at the power board Heating element failed Incorrect thermostat setting Strong draught The mains isolating switch on the wall, circuit breaker or fuses are off at the power board High condenser temperature Ventilation grills are blocked Product blocking air grill Evaporator coil fins blocked Strong draught Trays obstructing air flow Thermostat needs adjustment Ambient temperature > 25 C Evaporator coil iced up Condenser radiator blocked Thermostat faulty Temperature probe damaged Defrost cycle not suitable Fans not operating LED strip has failed Internal circuit breaker has tripped Boil off element failed Float switch faulty Float switch relay faulty High humidity atmosphere Build-up of ice in cabinet well due to blocked drain or cabinet not being level Turn mains switch on and check circuit breakers and fuses Check and replace Adjust (CW to increase temp) Relocate or shield cabinet Turn isolating switch circuit breaker or fuses on Clean condenser radiator Vacuum or remove blockage Place product on shelves Clean coil fins of debris etc. Relocate or shield cabinet Re-position trays on shelves Adjust the controller Adjust store air conditioning De-ice coil Remove dust and debris Replace the controller Replace temperature probe Adjust to match environment Have fans checked/replaced Replace LED strip Have wiring checked and reset circuit breaker Have element replaced Have switch replaced Have relay replaced Temporary condition, no remedy Clear drain, level cabinet and defrost ice Service Personnel Only The table entries in italics indicate actions to be taken only by qualified Service Personnel. IN-FUS-HC Future Products Group

14 Dixell XR40CX Alarm Responses - TROUBLE SHOOTING Probe Faults P1, P2, P3 or P4 Alarm Probe fault: Check appropriate probe wiring and probe resistance. Repair or replace as required. HA Alarm HA Alarm High cabinet internal temperature alarm: Clean condenser and condenser pre filter if fitted. Check evaporator coil for ice build-up and defrost as required. Check for correct air circulation. Check refrigeration system for correct operation. HA2 Alarm HA2 Alarm High discharge pipe temperature alarm: Clean condenser and condenser pre filter if fitted. Check condenser fan for correct operation. Check gas pressures, system may be over charged or low on refrigerant. Part No Rev. P June Fusion, Food & Beverage Cabinet

15 CLEANING Cautions - CLEANING Power ALWAYS TURN THE POWER SUPPLY OFF BEFORE CLEANING. Water THIS UNIT IS NOT WATERPROOF. DO NOT USE A WATER JET SPRAY TO CLEAN THE INTERIOR OR EXTERIOR OF THIS CABINET. Exterior - CLEANING Painted and Metal Surfaces Painted, stainless steel or aluminium surfaces should be cleaned with hot soapy water or a good quality metal cleaning compound. DO NOT clean surfaces with abrasive pads or cleaners (e.g. Scotchbrite pads or Jif), as paint, stainless steel and aluminium surfaces will be damaged. Interior - CLEANING Condensate Tray The condensate boil off heater is only designed to handle cooling-coil defrosting liquid that drains from the well. DO NOT fill the well with liquid, or attempt to hose it out as the condensate tray will overflow and leak onto the floor. Shelves & Trays Shelves and trays can be removed for cleaning. They should be cleaned with hot soapy water, or in a dishwasher. Do not use abrasive pads or cleaners (e.g. Scotchbrite pads or Jif), as these may damage surfaces. Continued on next page IN-FUS-HC Future Products Group

16 Interior cont. - CLEANING Cabinet Well After removing the trays and shelves, remove two screws to allow the fan deck and coil cover to be lifted off. Take care not to stretch the fan leads or damage the coil fins. When replacing the fan deck, make sure that it is correctly located and that the leads are not trapped by metal parts. Cooling Fins If there is debris stuck in the cooling fins, it is best to use a wet and dry vacuum cleaner to suck it out. DO NOT attempt to hose debris from fins. Caution: The fins are very sharp. Take extra care when cleaning this area. Temperature Probe Take care not to damage or move the temperature probes, when cleaning the cooling fins. Drain Holes Make sure that the condensate drain in the cabinet base is free of debris. If the drains become blocked, and water cannot drain away, the evaporator cooling coils may be damaged by a build-up of ice. Part No Rev. P June Fusion, Food & Beverage Cabinet

17 Routines - CLEANING Schedules To maintain optimum performance, the following cleaning routine should be scheduled on a regular basis. Initially, the following cleaning should be scheduled monthly, but this period may be adjusted to match the environmental conditions. Condenser Radiator Remove the front grill to reveal the condenser radiator. For efficient refrigeration performance, the condenser radiator must be kept clean, (see Servicing, Condenser Radiator). Regular vacuuming will prevent a build-up of dust and fluff, but periodic cleaning of the fins, by a refrigeration engineer, is recommended. ACR Tray Remove any debris that may have accumulated in the ACR tray. Warning Failure to carry out routine cleaning/servicing schedules will void the warranty on the refrigeration equipment. Inspection As part of the cleaning routine, the controls, mechanical parts and electrical wiring should be inspected for damage, deterioration or need of adjustment. Correction If any small faults are found, have them attended to promptly by a competent serviceman. Don t wait until they cause a complete breakdown. IN-FUS-HC Future Products Group

18 INSTALLATION Regulations - INSTALLATION Compliance with Local Requirements It is very important that your door-less cabinet is installed correctly and that the operation is correct before use. Installation must comply with local electrical, health & safety and hygiene requirements. Operational Safety The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Preparation - INSTALLATION Unpacking Unpack and check unit for damage and report any damage to the carrier and supplier. The cabinet is supplied fully assembled. Report any deficiencies to your supplier. Cabinet Preparation Remove all tapes, ties and packers, used to prevent movement during transit. Lift out the deck trays and grills to gain access to the cabinet well. Power Supply Before connecting to the power supply, check that the local supply is correct to that shown on the rating plate, located on the rear of the cabinet. Earthing WARNING-THIS APPLIANCE MUST BE EARTHED/GROUNDED Cabinets will usually be earthed via the earth conductors in the three core mains leads of the refrigerated and heated cabinet sections. Equipotential Bonding An externally accessible terminal is also provided for bonding cabinets together and to earth. Part No Rev. P June Fusion, Food & Beverage Cabinet

19 Location - INSTALLATION Ventilation To assist ventilation, locate the cabinet at least 20mm away from a back wall. Do not block the front ventilation grill, as this will cause the cabinet to overheat. The maximum recommended operating ambient temperature is 32 C. Access The mains power points supplying the cabinet should be accessible, to allow the cabinet to be turned off in case of emergency. The cabinet should also be positioned so the shelves are easily reached for loading and unloading. An isolating switch, circuit breaker and controls for the refrigerated section are behind the front grill. Draughts The refrigerated section features an air curtain to retain the cold air within the cabinet. A curtain of cold air falls from a linear vent, above the section, to be re-circulated through the evaporator cooling coils. The cabinet should not be sited where strong draughts will deflect the air curtain. If this happens, excess condensation will form on the products, and cooling will be less effective. Similarly, strong draughts can cause uneven heating in the upper section. Level Site Four rollers allow the cabinet to be easily positioned. It is important that the cabinet stands level, so that condensate will drain away from the well. If the cabinet is not level, both side to side and front to back, water may pond under the circulation fan and freeze. Ice will then build up into the impellor, which will start making a loud rattling noise. Adjust the two front jacking screws to level the cabinet. If the floor is not level, use shims under one of the rear rollers. IN-FUS-HC Future Products Group

20 Mains Lead SERVICING - SERVICING Lead Replacement The mains leads must only be replaced by the manufacturer, their service agent or similarly qualified person, in order to avoid a hazard. Lighting - SERVICING Protection The lighting and low power circuits are protected by a circuit breaker on the control gear chassis, located behind the front grill of the refrigerated section and on the back of the heated section. If the lights do not work but the rest of the cabinet is operating, get an electrician to check the lighting circuits. Caution DO NOT service lights without isolating the cabinet by unplugging it from the mains supply socket, or turning off the servicing isolation switch. LED Strips Light is provided by four strips of LEDs. Before replacing an LED strip, check the power supply. Individual LED modules cannot be replaced. A complete light unit must be used. Note that the light units are not all the same, so the correct type must be selected. Remove the plastic cover to access the LED unit. Connection is made with a plug and socket. Disengage the supply lead from the faulty unit, and reconnect it to the replacement unit. Replace the plastic cover. LED Power Supplies The LEDs are fed with a 700mA constant current. They consume approximately 19W per metre of strip length. The power supplies and driver modules are located on the control gear chassis, behind the heated section and below the refrigerated section. Continued on next page Part No Rev. P June Fusion, Food & Beverage Cabinet

21 Heating - SERVICING Heating Elements Radiant heating elements are used above the shelves, and the lower shelf is directly heated by a contact element. Temperature probes for the thermostat and thermometer are mounted above the upper shelf. Element Replacement To replace the upper radiant element, first remove the screws retaining the wire guard. The element assembly can then be released and a new one fitted. Because of the restricted space, it is easier to replace the radiant shelf elements by first removing the complete shelf assembly. To do this, the wiring must first be disconnected from behind the back panel. The base element can only be replaced by fitting a complete element/panel assembly. Note that it has fixings from the back of the cabinet as well as inside. Temperature Control The overall temperature of the heated section is controlled by a thermostat, on the back of the cabinet. Turn clockwise to increase temperature. It is important to confirm that the cabinet temperature gauge indicates at least 68 C. Thermometer Battery Replacement The digital thermometer is self-contained, fitted with two batteries. The thermometer is a push-fit in the cabinet, and may be extracted to replace the batteries. Fresh batteries should be fitted in pairs. Continued on next page IN-FUS-HC Future Products Group

22 Heating cont. - SERVICING Control Gear The control gear for the heated section is located under a removable panel, on the back of the cabinet. The MCB and LED power supply are here, together with connections to the heating and lighting circuits etc. Ventilation Fan A fan is mounted on the upper back of the cabinet. This circulates air through the top of the cabinet, to prevent surfaces becoming too hot to touch. It is important that the fan is operating correctly, and that its grill is not blocked with dust and fluff. Insufficient air circulation will allow surface temperatures to rise, and can result in shortened LED life. Refrigeration - SERVICING Caution DO NOT attempt to service the refrigeration equipment without isolating the cabinet by unplugging it from the mains supply socket. Access to Control Gear etc. The control gear chassis is reached by removing the louver panel from the front of the cabinet. The chassis houses the refrigeration controller, mains isolation switch, MCB, LED power supply and the terminal block for all interconnections. Remove the four screws retaining the lower side panel to access the interior of the chassis. Continued on next page Part No Rev. P June Fusion, Food & Beverage Cabinet

23 Refrigeration cont. - SERVICING Access to Condensing Unit etc. The condenser unit and boil off element can be reached from the front and rear of the cabinet. Remove the fixing screws to open the cabinet back panel and to remove the front louvers. Condenser Ventilation For efficient refrigeration performance, the condenser radiator and front and rear louvers must be kept clean. Failure to do this will lead to a build-up of dust, and restricted airflow will prevent the unit from working properly. The compressor may overheat and the cabinet temperature may rise. Regular vacuuming will prevent a build-up of dust and fluff, however, the condenser and radiator should be cleaned with compressed air during the mandatory three monthly service checks by a refrigeration engineer. Be very careful not to bend or damage the soft aluminium fins when vacuuming the radiator. If the fins are flattened, airflow will be restricted and overheating will again result. Controller Adjustment The controller must NOT be tampered with by an unqualified person. The indicated temperature will be lower than the air temperature inside the cabinet, because the refrigeration compressor is controlled in response to the exit air temperature from the evaporator cooling coil. The controller can also display fault messages, caused by condenser overheating or low refrigerant gas pressure. Continued on next page IN-FUS-HC Future Products Group

24 Refrigeration cont. - SERVICING Probe Locations The temperature control probe is positioned in the off air stream from the evaporator coil. A second probe, inserted in the fins of the coil controls the defrost termination. A third probe (temperature sensor), is located in a pocket on the discharge line from the compressor. The function of this probe is to avoid the refrigeration system overheating. Thermometer A barrel thermometer is located in the return air duct, at the front of the cabinet. It will therefore indicate the temperature of the air returning from the display area, before passing through the cooling coil. This will be slightly higher than the product temperature. Fan Deck The fan deck is fitted with two fans, and is electrically connected to the cabinet with a plug and socket. After removing the retaining screws, the complete assembly can be removed for servicing. Take care to avoid trapping cables with the metalwork, when re-assembling Continued on next page Part No Rev. P June Fusion, Food & Beverage Cabinet

25 Refrigeration cont. - SERVICING Condensate Disposal The condensate disposal system consists of a water tray, a water level detector and a boil-off element with an over temperature cut-out. If the element fails, it may be replaced by springing it from the mounting bracket. Cut and splice the leads and protect with heat-shrink sleeves. ACR Fault Finding Guide First check if the condensate water level probe in the ACR tank is dirty and needs cleaning (a dirty probe may either fail to detect water, or give a false indication of water) clean if required. Check the Finder Level Control unit sensitivity range adjustment is set to 75k. If the sensitivity is set too low, the Finder Level Control unit may not detect the condensate water and won t switch on the ACR element. If the sensitivity is set too high, the Finder Level Control unit may get a false indication of the condensate water and switch on the ACR element without water present. Fault: ACR element is on continuously when no condensate water is present. Test: Check if the Finder Level Control unit is faulty by disconnecting the probe wire from terminal B1 on the Finder Level Control unit. With the cabinet power turned on and after waiting 10 seconds, check for 230V across terminals 11 and 14. If 230v is not present across terminals 11 & 14, replace the Finder Level Control unit. Fault: ACR element does not heat even though condensate water is present and touching the water level probe. Test: First check the ACR unit has a 230V power supply. Next, check the Finder Level Control unit water sensing circuit by shortcircuiting the level sensor terminals B1 & B3. Turn the cabinet power on and wait 10 seconds and then check if the ACR element heats. If the element heats, check for an open circuit in the water sensing probe circuit and clean the probe. If the element does not heat, turn the cabinet power off and take the element wire out of terminal 11 and wire into terminal 14 on the Finder Level Control unit. Turn the cabinet power on and wait 10 seconds and then check if the ACR element heats. If the element heats, replace the Finder Level Control Unit. If the element does not heat replace the element and Therm-O-Disc assembly. Note: The element and Therm-O-Disc are supplied as a complete assembly. Continued on next page IN-FUS-HC Future Products Group

26 Refrigeration cont. - SERVICING Temperature Regulator XR40CX Model XR40CX is a microprocessor based controller. It is provided with three NTC or PTC probe inputs, the first one for temperature control, the second one, to be located onto the evaporator, to control the defrost termination temperature, the third one, optional, to connect to the HOT KEY terminals to signal the condenser temperature alarm or to display a temperature. The indicated set-point temperature will be lower than the air temperature inside the cabinet, because the refrigeration compressor is controlled in response to the exit air temperature from the evaporator cooling coils. The HOT KEY output allows one to programme the controller by means the HOT KEY programming keyboard. The instrument is fully configurable through special parameters that can be easily programmed through the keyboard. XR40CX Compressor Control The regulation is performed according to the temperature measured by the thermostat probe with a positive differential from the set point: if the temperature increases and reaches set point plus differential the compressor is started and then turned off when the temperature reaches the set point value again. ON Time In case of a fault in the thermostat probe the start and stop of the compressor are timed through parameters COn and COF. XR40CX Defrost Control Parameters are used to control the interval between defrost cycles (IdF), its maximum length (MdF) and two defrost modes: timed or controlled by the evaporator s probe (P2P). In this cabinet, the start of the defrost cycle is timed, but the cycle will be terminated as soon as the defrost probe reaches the pre-determined temperature. At the end of defrost dripping time is started, its length is set in the FSt parameter. With FSt =0 the dripping time is disabled Continued on next page Part No Rev. P June Fusion, Food & Beverage Cabinet

27 Refrigeration cont. - SERVICING XR40CX Key Functions KEY FUNCTION To display target set point; in programming mode it selects a parameter or confirm an operation (DEF) To start a manual defrost (UP): To see the max. stored temperature; in programming mode it browses the parameter codes or increases the displayed value (DOWN): To see the min stored temperature; in programming mode it browses the parameter codes or decreases the displayed value To switch the instrument off, if onf = off. Not enabled To lock & unlock the keyboard To enter into programming mode To return to the temperature display mode XR40CX LED Functions LED MODE FUNCTION ON Flashing ON Flashing ON ON ON ON Flashing Compressor enabled Anti-short cycle delay enabled Defrost enabled Drip time in progress An alarm is occurring Continuous cycle is running Energy saving enabled Measurement unit Programming phase Continued on next page IN-FUS-HC Future Products Group

28 Refrigeration cont. - SERVICING XR40CX Min & Max Recorded Temperature Press and release the key. Lo will be displayed followed by the minimum temperature recorded. Press the key again or wait 5s to restore the normal display. Press and release the key. Hi will be displayed followed by the maximum temperature recorded. Press the key again or wait 5s to restore the normal display. XR40CX Reset Max/Min Temperature Memory Press the SET key for more than 3s, while the max. or min. temperature is displayed. (rst message will be displayed) To confirm the operation the rst message starts blinking and the normal temperature will be displayed. XR40CX Display the Setpoint To show the set-point value, press and immediately release the SET key. Press and immediately release the SET key or wait for 5 seconds to display the probe temperature again. XR40CX Change the Set-point To change the set-point value, press the SET key for more than 2 seconds; The value of the set-point will be displayed and the C or F LED starts blinking; To change the set value push the or arrows within 10s. To memorise the new set-point value push the SET key again or wait 10s. XR40CX Start a Manual Defrost To start a manual defrost, press the (DEF) key for more than 2 seconds. XR40CX Programming Mode Enter the Programming mode by pressing the (the C or F LED starts blinking). keys for 3s Use the or keys to select the required parameter. Press the key to display its value. Use the or keys to change its value. Press to store the new value and move to the following parameter. To exit Programming mode, press or wait 15s without pressing a key. NOTE: the set value is stored even when the procedure is exited by waiting for the time-out to expire. Continued on next page Part No Rev. P June Fusion, Food & Beverage Cabinet

29 Refrigeration cont. - SERVICING XR40CX The Hidden Menu The hidden menu includes all the parameters of the instrument. TO ENTER THE HIDDEN MENU Enter the Programming mode by pressing the keys for 3s, (the C or F LED starts blinking). Release the keys, then press the keys again, for more than 7s. The Pr2 label will be displayed immediately followed from the Hy parameter. NOW YOU ARE IN THE HIDDEN MENU. Select the required parameter. Press the key to display its value Use or to change its value. Press to store the new value and move to the following parameter. To exit: Press or wait 15s without pressing a key. NOTE 1: If no parameter is present in Pr1, after 3s the nop message is displayed. Keep the keys pushed till the Pr2 message is displayed. NOTE 2: The set value is stored even when the procedure is exited by waiting for the time-out period to expire. TO MOVE A PARAMETER FROM THE HIDDEN MENU TO THE FIRST LEVEL AND VICEVERSA. Each parameter present in the HIDDEN MENU can be removed or put into THE FIRST LEVEL (user level) by pressing In HIDDEN MENU when a parameter is present in the First Level the decimal point is shown. XR40CX Locking and Unlocking the Keyboard To lock the keyboard, press the keys for more than 3 s. The POF message will be displayed, followed by the previous temperature display. If a key is pressed more than 3s the POF message will be displayed. To unlock the keyboard, press the message is displayed. keys for more than 3s, till the Pon Continued on next page IN-FUS-HC Future Products Group

30 Refrigeration cont. - SERVICING FPG Settings Note that the following settings are Dixell factory defaults. Refer to the Specification section for the correct FPG settings for your cabinet. Dixell Default Settings Label Name Range Default Setting Set Set point LS US -5.0 Hy Differential 0, C/ F 2.0 LS Minimum set point -50 C SET/-58 F SET US Maximum set point SET 110 C/ SET 230 F 110 Ot Thermostat probe calibration C / F 0.0 P2P Evaporator probe presence n=not present; Y=pres. Y OE Evaporator probe calibration C / F 0.0 P3P Third probe presence n=not present; Y=pres. n O3 Third probe calibration C / F 0 P4P Fourth probe presence n=not present; Y=pres. n O4 Fourth probe calibration C / F 0 OdS Outputs delay at start up min 0 AC Anti-short cycle delay 0 50 min 1 rtr P1-P2 percentage for regulation (100=P1, 0=P2) 100 CCt Continuous cycle duration h 0.0 CCS Set point for continuous cycle ( ,0 C) ( F) -5 COn Compressor ON time with faulty probe min 15 COF Compressor OFF time with faulty probe min 30 CF Temperature measurement unit C F C res Resolution in=integer; de= dec.point de Lod Probe displayed P1;P2 P1 red2 X-REP display P1 - P2 - P3 - P4 - SEt - dtr P1 dly Display temperature delay min (10 sec.) 0 dtr P1-P2 percentage for display tdf Defrost type EL=el. heater; in= hot gas EL dfp Probe selection for defrost termination np; P1; P2; P3; P4 P2 dte Defrost termination temperature C 8 IdF Interval between defrost cycles ore 6 MdF (Maximum) length for defrost min 30 dsd Start defrost delay 0 99min 0 dfd Displaying during defrost rt, it, SEt, DEF it dad MAX display delay after defrost min 30 Fdt Draining time min 0 dpo First defrost after start-up n=after IdF; y=immed. n daf Defrost delay after fast freezing 0 23h e ALc Temperature alarms configuration re= related to set; Ab = absolute Ab ALU MAXIMUM temperature alarm Set C; Set 230 F 110 ALL Minimum temperature alarm C Set/ -58 F Set Continued on next page Part No Rev. P June Fusion, Food & Beverage Cabinet

31 Refrigeration cont. - SERVICING Dixell Default Settings cont. XR40CX Hot Key Label Name Range Default Setting AFH Differential for temperat. alarm recovery (0,1 C 25,5 C) (1 F 45 F) 1 ALd Temperature alarm delay min 15 dao Delay of temperature alarm at start up 0 23h e AP2 Probe for temperat. alarm of condenser np; P1; P2; P3; P4 P4 AL2 Condenser for low temperat. alarm ( C) ( F) -40 AU2 Condenser for high temperat. alarm ( C) ( F) 110 AH2 Differ. for condenser temp. alar. recovery [0,1 C 25,5 C] [1 F 45 F] 5 Ad2 Condenser temperature alarm delay (min.), 255=nU 15 da2 Delay of cond. temper. alarm at start up h 50 1,3 bll Compressor OFF for condenser low temperature alarm n(0) - Y(1) n AC2 Compressor OFF for condenser high temperature alarm n(0) - Y(1) n i1p Digital input polarity op=opening; CL=closing cl i1f Digital input configuration EAL, bal, PAL, dor; def; Htr, AUS EAL did Digital input alarm delay 0 255min 5 Nps Number of activation of pressure switch odc Compress status when open door no; Fan; CPr; F_C no rrd Regulation restart with door open alarm n Y y HES Differential for Energy Saving (-30 C 30 C) (-54 F 54 F) 0 Adr Serial address PbC Kind of probe Ptc; ntc ntc onf on/off key enabling nu, off; ES nu dp1 Room probe display dp2 Evaporator probe display dp3 Third probe display dp4 Fourth probe display rse Set operating value actual set -- rel Software release Ptb Map code To program the controller from a Hot Key: Turn OFF the instrument. Insert a programmed Hot Key into the 5 PIN socket and then turn the Controller ON. The parameter list of the Hot Key is automatically downloaded into the Controller memory, the dol will blink, followed a by a flashing End. After 10 seconds the instrument will restart working with the new parameters. Remove the Hot Key. NOTE the message Err is displayed if programming fails. In this case turn the unit off and then on again, if you want to restart the download again, or remove the Hot Key to abort the operation. Continued on next page IN-FUS-HC Future Products Group

32 Refrigeration cont. - SERVICING XR40CX Alarm Signals Message Cause Outputs P1 Room probe failure Compressor output acc. to par. Con and COF P2 Evaporator probe failure Defrost end is timed P3 Third probe failure Outputs unchanged P4 Fourth probe failure Outputs unchanged HA Maximum temperature alarm Outputs unchanged. LA Minimum temperature alarm Outputs unchanged. HA2 Condenser high temperature It depends on the Ac2 parameter LA2 Condenser low temperature It depends on the bll parameter da Door open Compressor according to rrd EA External alarm Output unchanged. CA Serious external alarm (i1 F=bAL) All outputs OFF. CA Pressure switch alarm (i1 F=PAL) All outputs OFF XR40CX Alarm Recovery Probe alarms P1, P2, P3 and P4 start some seconds after the fault in the related probe; they automatically stop some seconds after the probe restarts normal operation. Check connections before replacing the probe. Temperature alarms HA, LA, HA2 and LA2 automatically stop as soon as the temperature returns to normal values. Alarms EA and CA (with i1 F=bAL) recover as soon as the digital input is disabled. Alarm CA (with i1 F=PAL) recovers only by switching off and on the instrument. XR40CX Other Messages Message Pon PoF nop noa Cause Keyboard unlocked. Keyboard locked In programming mode: none parameter is present in Pr1 On the display or in dp2, dp3, dp4: the selected probe is not enabled No alarm is recorded. XR40CX Connections Part No Rev. P June Fusion, Food & Beverage Cabinet

33 SPECIFICATIONS Mechanical - SPECIFICATIONS IN-FUS-HC10-A004 CABINET MODEL Cold Section Hot Section Height Width Depth Levelling adjustment Dry Weight 1480 mm 1009 mm 714 mm +30mm 230 kg Number of Shelves 1 + base 1 + base Display Area 0.7 m m 2 Refrigerant R-134a N/A Refrigerant charge, see Cabinet Rating Label approx. 400 g N/A Condensate capacity 3 litres N/A Electrical - SPECIFICATIONS IN-FUS-HC10-A004 CABINET MODEL Cold Section Hot Section Voltage V 50 Hz 1 Maximum Power 1.2 kw 1.9 kw ACR Element Power 400 W N/A Maximum Current 5.3 A 8.3 A Connection Lights Energy Consumption in 25ºC, 60%RH Ambient Three core cable with 3 pin plug 2 x LED strips Cool White 0.75 kwh/h Three core cable with 3 pin plug 2 x LED strips Warm White IN-FUS-HC Future Products Group

34 Cabinet Performance - SPECIFICATIONS Refrigerated Section Performance Operating Temperature Average Internal Humidity Climatic Class 3 Test Conditions +2 to +4 C 70% RH 25 C Ambient with 60% RH Controller Settings - SPECIFICATIONS Application Specific Settings The following table specifies the settings for the Dixell XR40CX Controller which are specifically for this FPG cabinet. XR40CX Settings Parameter Description Setting Unit / Range Set Set Point -4 degc Hy Differential 3.5 degc P3P Third Probe Used Y n=no, Y=yes AC Anti Short Cycle Delay 0 Min C0n Comp On Time - Faulty Probe 4 Min C0F Comp Off Time - Faulty Probe 6 Min dte Defrost Terminate Temp 6 degc IdF Interval Between Defrosts 2 Hrs dfd Display During Defrost DEF rt, it, Set, DEF AP2 Probe For High Discharge Temp Alarm P3 np, P1, P2, P3, P4 AU2 High Discharge Temp Alarm Set Point 100 degc AH2 High Discharge Temp Alarm Diff 25 degc Ad2 High Discharge Temp Alarm delay 0 Min da2 High Discharge Alarm Delay At Start 0 Min AC2 Comp Off For High Discharge Temp Alarm Y(1) n(0)=no, Y(1)=yes Part No Rev. P June Fusion, Food & Beverage Cabinet

35 Compliance - SPECIFICATIONS Safety Aspects This cabinet has been designed to comply with the relevant requirements of the following specifications: AS/NZS 3100 : General Requirements for Electrical Equipment IEC : General Requirements IEC : Particular requirements for refrigerating appliances, icecream appliances and ice-makers IEC : Particular requirements for motor compressors IEC : Particular requirements for commercial electric hot cupboards IEC : Particular requirements for commercial refrigerating appliances with an incorporated or remote refrigerant condensing unit or compressor Hazardous Substances The cabinet does not contain any of the following, in its construction: Asbestos PCBs (Oils containing polychlorinated biphenyl) Mercury Improvements - SPECIFICATIONS On-going Development FPG reserves the right to change specifications and construction, as part of ongoing product improvement. IN-FUS-HC Future Products Group

36 ELECTRICAL CIRCUIT DIAGRAM Model: IN-FUS-HC10-A mm Open-front Food & Beverage Cabinet Part No Rev. P June Fusion, Food & Beverage Cabinet

37 SPARE PARTS Cabinet Serial Number When ordering spare parts, it is important to quote the Serial Number printed on the label fixed to the cabinet. This will enable FPG to trace details of the build specification of your particular cabinet, and hence ensure that spare parts are fully compatible. To satisfy warranty conditions, and ensure optimum performance, use only FPG supplied spare parts. Part Description FPG Part No Side glass kit Chicken Tray base with load limit Chicken Tray top shelf One-piece Shelf LED power supply 24V 60W LED Driver 700mA Anti-surge thermistor 10 Ohm 3A Cold section top light LED assembly Cold section top light plastic cover Cold section bottom light LED assembly Cold section bottom light plastic cover Heated section top light LED assembly Heated section top light plastic cover Heated section shelf light LED assembly Heated section shelf light plastic cover Ventilation fan Condensate Water Sensor, Finder ACR Boil off Element 400W Quartz Heating Element 600W Thermostat 90 C Thermostat Knob Danfoss SC18 Compressor Condenser Fan Unada 200mm 1800rpm Evaporator EBM Papst ACi Barrel Thermometer Digital Thermometer Digital Thermometer Battery Toroid Ring 12.5mm Circuit Breaker 6 Amp Mains Switch DPST 16A 250V Rocker Light Switch Rocker Dixell XR40CX digital refrigeration controller NTC temperature probe EMI Line Filter Filter Toroid 23217(22565) Thermal Fuse G4A01152C Product Manual for Fusion Food & Beverage cabinet IN-FUS-HC Future Products Group

38 MECHANICAL DRAWINGS IN-FUS-HC10-A004 Part No Rev. P June Fusion, Food & Beverage Cabinet

39 IN-FUS-HC Future Products Group

40 Part No Rev. P June 2017

Popcorn Warmer Cabinet

Popcorn Warmer Cabinet Popcorn Warmer Cabinet Copyright July 2016 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or

More information

Refrigerated Milk Drawer

Refrigerated Milk Drawer Refrigerated Milk Drawer Copyright Septamber 2016 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any

More information

Refrigerated Cabinets

Refrigerated Cabinets Refrigerated Cabinets Copyright June 2017 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or

More information

Open Front Food & Drinks Cabinet AS/NZS

Open Front Food & Drinks Cabinet AS/NZS Open Front Food & Drinks Cabinet AS/NZS Copyright November 2017 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

Refrigerated Cabinets Square Format

Refrigerated Cabinets Square Format Refrigerated Cabinets Square Format Copyright December 2017, Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

Inline GN Series Refrigerated Well

Inline GN Series Refrigerated Well Inline GN Series Refrigerated Well Copyright June 2017 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in

More information

Refrigerated Cabinets Curved Format

Refrigerated Cabinets Curved Format Refrigerated Cabinets Curved Format Copyright August 2018, Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

Refrigerated Cabinets Curved Format

Refrigerated Cabinets Curved Format Refrigerated Cabinets Curved Format Copyright August 2018 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

IKEA USA Refrigerated Cabinets

IKEA USA Refrigerated Cabinets IKEA USA Refrigerated Cabinets Copyright March 2017 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any

More information

Digital Controller XR70CX. Operating Manual. 5/10 Rev. B

Digital Controller XR70CX. Operating Manual. 5/10 Rev. B Digital Controller XR70CX Operating Manual 5/10 Rev. B 139734 Contents General Warnings 3 General Description 3 Regulation 3 Defrost 3 Fans 4 Front Panel Commands 4 Parameters 6 Installation and Mounting

More information

Copyright July 2017 Future Products Group Limited. All rights reserved.

Copyright July 2017 Future Products Group Limited. All rights reserved. Heated Cabinets Copyright July 2017 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any

More information

Commercial Freezer Service Manual

Commercial Freezer Service Manual Commercial Freezer Service Manual SOLID DOOR TOP MOUNT REACH-IN PTM49F Please read this manual completely before attempting to install or operate this equipment. TABLE OF CONTENTS 1. FEATURE CHART 1-1.

More information

XR60C ,QVWDOOLQJDQG2SHUDWLQJ,QVWUXFWLRQV. Digital controller with defrost and fans management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS

XR60C ,QVWDOOLQJDQG2SHUDWLQJ,QVWUXFWLRQV. Digital controller with defrost and fans management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS Digital controller with defrost and fans management XR60C CONTENTS 1. GENERAL WARNING 1 2. GENERAL DESCRIPTION 1 3. CONTROLLING LOADS 1 4. FRONT PANEL COMMANDS 1 5. TEMPERATURE ALARM AND ITS DURATION RECORDING

More information

Commercial Refrigerator Service Manual

Commercial Refrigerator Service Manual Commercial Refrigerator Service Manual SOLID DOOR TOP MOUNT REACH-IN PTM49R Please read this manual completely before attempting to install or operate this equipment. TABLE OF CONTENTS 1. FEATURE CHART

More information

dixel Installing and Operating Instructions PRELIMINAY

dixel Installing and Operating Instructions PRELIMINAY . GENERAL WARNING XW6K - AFV PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument for easy and quick reference. The instrument shall not be used

More information

Copyright September 2018 Future Products Group Limited. All rights reserved.

Copyright September 2018 Future Products Group Limited. All rights reserved. Ambient Cabinets Copyright September 2018 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or

More information

XR60CX. Installation and Operating Instructions. Digital controller with defrost and fans management. + + To return to the room temperature display.

XR60CX. Installation and Operating Instructions. Digital controller with defrost and fans management. + + To return to the room temperature display. Digital controller with defrost and fans management XR60CX CTENTS 1. GENERAL WARNING 1 2. GENERAL DESCRIPTI 1 3. CTROLLING LOADS 1 4. FRT PANEL COMMANDS 1 5. MAX & MIN TEMPERATURE MEMORIZATI 1 6. MAIN

More information

OPERATING INSTRUCTIONS ULTF 80 / 220 / 320 / 420

OPERATING INSTRUCTIONS ULTF 80 / 220 / 320 / 420 OPERATING INSTRUCTIONS ULTF 80 / 220 / 320 / 420 INDEX........................................................... PAGE Before using the appliance...............................................................

More information

dixel Installing and Operating Instructions

dixel Installing and Operating Instructions XW20K AND T620 V620 CX620 1. GENERAL WARNING PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument for easy and quick reference. The instrument

More information

Ambient Cabinets Curved Format

Ambient Cabinets Curved Format Ambient Cabinets Curved Format Copyright September 2018 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in

More information

XH50P - XH55P Temperature/relative humidity probe with RS485 serial line

XH50P - XH55P Temperature/relative humidity probe with RS485 serial line XH50P - XH55P Temperature/relative humidity probe with RS485 serial line 1. GENERAL WARNINGS 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument

More information

XW40K AND T620T - T620 V620 CX620

XW40K AND T620T - T620 V620 CX620 XW40K AND T620T - T620 V620 CX620 1 GENERAL WARNING... 1 2 GENERAL DESCRIPTI... 1 3 CTROLLING LOADS... 1 4 SPECIAL FUNCTIS... 1 5 KEYBOARDS... 1 6 AUTOMATIC KEYBOARD LOCK (LY FOR T620T)... 2 7 CTROLLER

More information

User Instructions Lab* Frost. Ultra Low Temperature Freezers Model LAB

User Instructions Lab* Frost. Ultra Low Temperature Freezers Model LAB User Instructions Lab* Frost Ultra Low Temperature Freezers Model LAB SAFETY INFORMATIONS The LAB freezers contains environmentally friendly but flammable refrigerants. It means danger of explosion if

More information

dixel Installing and Operating Instructions 1592027050 Digital controller for medium-low temperature refrigeration applications XW60L 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual

More information

Top Mount Full Length Swinging Doors

Top Mount Full Length Swinging Doors Top Mount Full Length Swinging Doors *Shown in FT103SD3 model Model FT77SD FT103SD3 FT138SD Width 77 103 138½ Depth 32 32 32 Height 86 ½ 86 ½ 86 ½ Volume/cu. Ft. 77 103 140 Doors 3 3 4 Door Size 23 x 66

More information

Dixell Installing and Operating Instructions release 7.0

Dixell Installing and Operating Instructions release 7.0 XR160C - XR160D - XR170C - XR170D - XR162C - XR172C CONTENTS 1. GENERAL WARNING 2 1.1 Please read before using this manual 2 1.2 Safety Precautions 2 2. GENERAL DESCRIPTION 2 3. CONTROLLING LOADS 2 3.1

More information

XR77CX. dixel Installing and Operating Instructions Digital controller for medium-low temperature refrigeration applications

XR77CX. dixel Installing and Operating Instructions Digital controller for medium-low temperature refrigeration applications Digital controller for medium-low temperature refrigeration applications XR77CX 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the

More information

Time KEY COMBINATIONS: + To lock & unlock the keyboard. + To enter in programming mode. + To return to the room temperature display. 4.

Time KEY COMBINATIONS: + To lock & unlock the keyboard. + To enter in programming mode. + To return to the room temperature display. 4. Digital controller for medium-low temperature refrigeration applications XW40L 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the

More information

XWA11V. Walk-In Temp / Door /Alarm / Light Module

XWA11V. Walk-In Temp / Door /Alarm / Light Module XWA11V Walk-In Temp / Door /Alarm / Light Module 1. GENERAL DESCRIPTION Model XWA11V, 100x64 mm format, is a microprocessor-based controller, suitable for temperature monitoring and alarming in a walk-in

More information

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring 1. GENERAL DESCRIPTION Model XWA11V-KIT, 100x64 mm format, is a microprocessor based light and alarm management controller,

More information

Operating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module

Operating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module XWA11V Walk-In Temp / Door /Alarm / Light Module 1. GENERAL DESCRIPTION Model XWA11V, 100x64 mm format, is a microprocessor-based controller, suitable for temperature monitoring and alarming in a walk-in

More information

XW70L. Digital controller for medium-low temperature refrigeration applications AUX 1. GENERAL WARNING 2. GENERAL DESCRIPTION 3.

XW70L. Digital controller for medium-low temperature refrigeration applications AUX 1. GENERAL WARNING 2. GENERAL DESCRIPTION 3. Digital controller for medium-low temperature refrigeration applications XW70L 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the

More information

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring 1. GENERAL DESCRIPTION Model XWA11V-KIT, 100x64 mm format, is a microprocessor based light and alarm management controller,

More information

MINITOP Refrigerated Self-Service Display underneath

MINITOP Refrigerated Self-Service Display underneath MINITOP Refrigerated Self-Service Display underneath Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4 Spare parts page 6 Rue Charles

More information

Rev 0 09-FEB XR75CX Digital Controller for Medium-Low Temperature Refrigeration Applications Installation and Operation Manual

Rev 0 09-FEB XR75CX Digital Controller for Medium-Low Temperature Refrigeration Applications Installation and Operation Manual 026-1210 Rev 0 09-FEB-2011 XR75CX Digital Controller for Medium-Low Temperature Refrigeration Applications Installation and Operation Manual Retail Solutions 3240 Town Point Drive NW Suite 100 Kennesaw,

More information

Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4 Spare parts page 6

Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4 Spare parts page 6 INOUK Upright refrigerated display Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4 Spare parts page 6 Rue Charles Hermite Z.I. des

More information

OMNITOP Refrigerated Display with Ventilated Cooling

OMNITOP Refrigerated Display with Ventilated Cooling OMNITOP Refrigerated Display with Ventilated Cooling Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4 Spare parts page 6 Rue Charles

More information

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill

More information

Electronic Controller For Refrigeration XLR130 XLR170

Electronic Controller For Refrigeration XLR130 XLR170 Electronic Controller For Refrigeration XLR130 XLR170 Instructions Manual COOL OOLMATE XLR130C XLR170C INDEX 1. GENERAL WARNING 3 2. GENERAL DESCRIPTION 3 3. CONTROLLING LOADS 3 4. KEYBOARD 5 5. REAL TIME

More information

XH260L XH260V. Dixell Operating instructions TEMPERATURE AND HUMIDITY CONTROLLER 1. GENERAL WARNING

XH260L XH260V. Dixell Operating instructions TEMPERATURE AND HUMIDITY CONTROLLER 1. GENERAL WARNING XH260L XH260V TEMPERATURE AND HUMIDITY CTROLLER 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument for easy and quick

More information

REVERSO. Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4-6 Spare parts page 7

REVERSO. Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4-6 Spare parts page 7 REVERSO Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4-6 Spare parts page 7 Rue Charles Hermite Z.I. des Sables BP 59 54110 Dombasle

More information

AIR COOLED CHILLERS MODELS: MPCA0005 MPCA0150 INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

AIR COOLED CHILLERS MODELS: MPCA0005 MPCA0150 INSTALLATION, OPERATION, AND MAINTENANCE MANUAL MOTIVAIR COOLING SOLUTIONS AIR COOLED CHILLERS MODELS: MPCA0005 MPCA0150 INSTALLATION, OPERATION, AND MAINTENANCE MANUAL This chiller has been factory run tested to the specified water pressure *****DO

More information

Rev 1 24-MAY XR75CX Digital Controller for Medium-Low Temperature Refrigeration Applications Installation and Operation Manual

Rev 1 24-MAY XR75CX Digital Controller for Medium-Low Temperature Refrigeration Applications Installation and Operation Manual 026-1210 Rev 1 24-MAY-2012 XR75CX Digital Controller for Medium-Low Temperature Refrigeration Applications Installation and Operation Manual Retail Solutions 3240 Town Point Drive NW Suite 100 Kennesaw,

More information

Read and save these instructions

Read and save these instructions www.winemate.com Wine Cooling System WM-1500HZD, WM-2500HZD WM-3500HZD, WM-4500HZD WM-6500HZD, WM-8500HZD Installation, Use & Care Manual www.vinotemp.com Read and save these instructions Important Safety

More information

OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES. Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ATF2 ATR2

OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES. Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ATF2 ATR2 OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ABF1 ABF2 ABF3 ABR1 ABR2 ABR3 ABF1 ABR1 ATF2 ATR2 ABF3 ABR3 Please read the manual carefully and follow all instructions.

More information

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A Blast Chiller / Freezer Instruction Manual Model DN492-A DN494-A Safety Tips Position on a flat, stable surface. A service agent/qualified technician should carry out installation and any repairs if required.

More information

Read and save these instructions

Read and save these instructions www.winemate.com Wine Cooling System WM-1500HZD, WM-2500HZD WM-3500HZD, WM-4500HZD WM-6500HZD, WM-8500HZD Installation, Use & Care Manual www.vinotemp.com Read and save these instructions Important Safety

More information

UNIVERSAL R V3.0. NEW FEATURES on the V3.0

UNIVERSAL R V3.0. NEW FEATURES on the V3.0 UNIVERSAL R V3.0 NEW FEATURES on the V3.0 HEATING : As well as cooling, the Universal-R can now be used to control heating applications up to +105c, using the NTC probes supplied in box. For temperatures

More information

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB H SSGB Technical Data Sheet P/N 3018921_E EPH Certified to NSF-7 January 2018 F A C D E A G B We reserve the right to change or revise specifications and product design in connection with any feature of

More information

Heated Display Cabinet Installation & Operating Instructions

Heated Display Cabinet Installation & Operating Instructions Heated Display Cabinet Installation & Operating Instructions TABLE OF CONTENTS Page Introduction 2 Safety 2 Installation Instructions 2 Operating Instructions 3 Cleaning & Servicing 3 Troubleshooting 4

More information

Refrigerated air dryers

Refrigerated air dryers Refrigerated air dryers OPERATING AND MAINTENANCE MANUAL Original instructions 38178800319 OPERATING AND MAINTENANCE MANUAL - Contents 1 CONTENTS CONTENTS... 1 Chapter 1 IDRY ELECTRONIC CONTROLLER...

More information

Sf2+HF2 Sf2 Sf1 + Hf1 Sf1. 1 ON Fan1 enabled (only for XC30CX) 2 ON Fans enabled (only for XC30CX) kpa. Time

Sf2+HF2 Sf2 Sf1 + Hf1 Sf1. 1 ON Fan1 enabled (only for XC30CX) 2 ON Fans enabled (only for XC30CX) kpa. Time Digital controller for CDU management XC10CX and XC30CX 1. GENERAL WARNING... 1 2. GENERAL DESCRIPTION... 1 3. CONTROLLING LOADS... 1 4. FRONT PANEL COMMANDS... 1 5. OTHER FUNCTIONS... 1 6. MAIN INTERFACE...

More information

XW90LT. Digital controller for medium-low temperature refrigeration applications AUX 1. GENERAL WARNING 2. GENERAL DESCRIPTION 3.

XW90LT. Digital controller for medium-low temperature refrigeration applications AUX 1. GENERAL WARNING 2. GENERAL DESCRIPTION 3. Digital controller for medium-low temperature refrigeration applications XW90LT 1. GENERAL WARNING... 1 2. GENERAL DESCRIPTI... 1 3. CTROLLING LOADS... 1 4. FRT PANEL COMMANDS... 1 5. AUTOMATIC KEYBOARD

More information

REFRIGERATED ROOM & TEMPERATURE/HUMIDITY CONTROLLERS

REFRIGERATED ROOM & TEMPERATURE/HUMIDITY CONTROLLERS SECTION INDEX FUNCTIONS MODELS XLR100 COOL MATE - NT, MT AND LT APPLICATIONS - SERIAL OUTPUT Advanced multifunction controllers for NT refrigerated rooms XLR130 Advanced multifunction controllers for MT

More information

VF X Series. User Manual. SKOPE Vertical Freezer. MAN11137 Rev. 1.1 Sep VF650X

VF X Series. User Manual. SKOPE Vertical Freezer. MAN11137 Rev. 1.1 Sep VF650X VF X Series SKOPE Vertical Freezer MAN11137 Rev. 1.1 Sep. 2016 VF650X SKOPE Warranty Protection Register now for peace of mind It s quick and simple. Take a few minutes to register your SKOPE product and

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL Refrigerated Island Merchandiser FOR PARTS & SERVICE Contact: Piper Products, Inc. Phone: (800) 544-3057 Ask for Service Department IMPORTANT! This manual contains important

More information

XC10CX and XC30CX. Digital controller for CDU management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS 2. GENERAL DESCRIPTION

XC10CX and XC30CX. Digital controller for CDU management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS 2. GENERAL DESCRIPTION Digital controller for CDU management XC10CX and XC30CX 1. GENERAL WARNING... 1 2. GENERAL DESCRIPTION... 1 3. CONTROLLING LOADS... 1 4. FRONT PANEL COMMANDS... 1 5. OTHER FUNCTIONS... 1 6. MAIN INTERFACE...

More information

Upright Chiller & Freezer Service, Installation and Care Manual

Upright Chiller & Freezer Service, Installation and Care Manual Upright Chiller & Freezer Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment. Notify carrier of damage! Inspect all components

More information

FDM Series. User Manual. SKOPE Food Display Cabinet Integral models: FDM900i/1200i/1500i. Model FDM1200i

FDM Series. User Manual. SKOPE Food Display Cabinet Integral models: FDM900i/1200i/1500i. Model FDM1200i FDM Series SKOPE Food Display Cabinet Integral models: FDM900i/1200i/1500i Model FDM1200i MAN2056O Rev 2.0 Aug. 2010 Integral models: FDM900i/1200i/1500i SKOPE Food Display Cabinet MAN2056O Rev 2.0 Aug

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL Refrigerated Merchandisers with Air-Over Displays Refrigerated Low-Profile Mobile Merchandiser Refrigerated High-Profile Mobile Merchandiser Refrigerated Grab-N-Go Merchandiser

More information

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner GUARDIAN SERIES KNA4C9DP47L-1

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner GUARDIAN SERIES KNA4C9DP47L-1 GUARDIAN SERIES KNA4C9DP47L-1 Keep This Manual With Air Conditioner Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents AIR CONDITIONER

More information

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A Blast Chiller / Freezer Instruction Manual Model DN492-A DN494-A 1 Safety Tips Position on a flat, stable surface. A service agent/qualified technician should carry out installation and any repairs if

More information

Sf2+HF2 Sf2 Sf1 + Hf1 Sf1. DLT Prb. Ground

Sf2+HF2 Sf2 Sf1 + Hf1 Sf1. DLT Prb. Ground Digital controller for CDU management XC30CX 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument for easy and quick reference.

More information

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES) OWNER S MANUAL HIGH WALL INVERTER (English) (BSHVD1S SERIES) IMPORTANT As with any product that has moving parts or is subject to wear and tear, it is VERY IMPORTANT that you maintain your air conditioner

More information

Refrigerated Display Cabinet Installation and Operating Manual

Refrigerated Display Cabinet Installation and Operating Manual Refrigerated Display Cabinet Installation and Operating Manual TABLE OF CONTENTS Page Introduction 2 Safety 2 Installation Instructions 3 Operating Instructions 4 Cleaning 4 Servicing 5 Spare Parts 5 Troubleshooting

More information

VF Series. User Manual. SKOPE Vertical Freezer. MAN10521 Rev. 3.3 Jun VF1000

VF Series. User Manual. SKOPE Vertical Freezer. MAN10521 Rev. 3.3 Jun VF1000 VF Series SKOPE Vertical Freezer MAN10521 Rev. 3.3 Jun. 2016 VF1000 SKOPE Warranty Protection Register now for peace of mind It s quick and simple. Take a few minutes to register your SKOPE product and

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL CTRH SERIES 460 Southport Commerce Blvd. Spartanburg SC 29306 Phone: 864-574-6004 Fax: 864-574-6005 CTRH-4 Congratulations! You have just purchased the finest commercial

More information

Ui REFRIGERATOR SPEC SHEET

Ui REFRIGERATOR SPEC SHEET Ui REFRIGERATOR SPEC SHEET ISOMETRIC VIEW 19 7/8 20 1/2 32 3/4 FRONT VIEW NOTES: 1. CUTOUT DIMENSIONS: 20 1/2"W X 33"L X 20 3/4"D 2. CUTOUT DIMENSIONS ARE FOR REFRIGERATOR ONLY. REFER TO STAINLESS STEEL

More information

Read and save these instructions

Read and save these instructions www.winemate.com Customizable Wine Cooling System WM-4510HZD WM-6510HZD WM-8510HZD Installation, Use & Care Manual www.vinotemp.com Read and save these instructions Important Safety Information NOTES:

More information

Split Wall-Recessed Cooling System Operation Care Installation Manual

Split Wall-Recessed Cooling System Operation Care Installation Manual Split Wall-Recessed Cooling System Operation Care Installation Manual WM-2520SSW 2520SSW-LA WM-4520SSW 4520SSW-LA www.vinotemp.com Read and save these instructions Vinotemp International Corp 17631 S Susana

More information

Read and save these instructions

Read and save these instructions Split Ceiling-Mounted Cooling System Operation Care Installation Manual WM-2500SSD WM-2500SSD-LA WM-4500SSD WM-4500SSD-LA WM-6500SSD WM-6500SSD-LA WM-8500SSD WM-8500SSD-LA WM-12000SSD WM-12000SSD-LA www.vinotemp.com

More information

XH340L-V TEMPERATURE AND HUMIDITY CONTROLLER FOR SEASONING-MATURING CABINETS 1. GENERAL WARNING

XH340L-V TEMPERATURE AND HUMIDITY CONTROLLER FOR SEASONING-MATURING CABINETS 1. GENERAL WARNING XH340L-V TEMPERATURE AND HUMIDITY CTROLLER FOR SEASING-MATURING CABINETS 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument

More information

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA HIGH MID LOW DRY FAN COLL HEAT TIMER SLEEP SWING Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA F C This appliance shall be installed in accordance with: Manufacturer

More information

Read and save these instructions

Read and save these instructions Split Water-Cooled Central-Ducted Cooling System Operation Care Installation Manual WM-2500SSHWC WM-4500SSHWC WM-6500SSHWC WM-8500SSHWC WM-12000SSHWC www.vinotemp.com Read and save these instructions Vinotemp

More information

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time Operating instructions Page 14 Refrigerator Read the operating instructions before switching on for the first time 7085 039-00 LKv 5710 Content Disposal notes... 14 Description of the appliance... 14 Safety

More information

FWC860 Wine Cooler Installation, Use and Maintenance

FWC860 Wine Cooler Installation, Use and Maintenance FWC860 Wine Cooler Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu W :

More information

Read and save these instructions

Read and save these instructions Split Water-Cooled Through-Ceiling Cooling System Operation Care Installation Manual WM-2500SSOWC WM-4500SSOWC www.vinotemp.com Read and save these instructions Vinotemp International Corp 17631 S Susana

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL Refrigerated Cases with Air-Over Displays Refrigerated High Profile Grab-N-Go FOR PARTS & SERVICE Contact: Piper Products, Inc. Phone: (800) 544-3057 Ask for Service Department

More information

Read and save these instructions

Read and save these instructions Split Through-Ceiling Cooling System Operation Care Installation Manual WM-2500SSO WM-2500SSO-LA WM-4500SSO WM-4500SSO-LA www.vinotemp.com Read and save these instructions Vinotemp International Corp 17631

More information

Ceiling Split Cooling System Installation, Operation & Care Manual WM-2500SSD WM-4500SSD WM-6500SSD WM-8500SSD

Ceiling Split Cooling System Installation, Operation & Care Manual WM-2500SSD WM-4500SSD WM-6500SSD WM-8500SSD www.winemate.com Ceiling Split Cooling System Installation, Operation & Care Manual WM-2500SSD WM-4500SSD WM-6500SSD WM-8500SSD www.vinotemp.com Read and save these instructions Important Safety Information

More information

V 120 SG - V 160 SG. Instructions for use

V 120 SG - V 160 SG. Instructions for use V 120 SG - V 160 SG Instructions for use Warning As the appliance contains a flammable refrigerant, it is essential to ensure that the refrigerant pipes are not damaged. The quantity and type of the refrigerant

More information

Double Door - Dual Zone Wine Cooler

Double Door - Dual Zone Wine Cooler THE PERFECT BALANCE OF FUNCTION, STYLE AND RELIABILITY LAUNDRY - DISHWASHING - COOKING - COOLING Installation and Operating Manual Double Door - Dual Zone Wine Cooler WS38SDDX Stainless Steel Please read

More information

FWC152, FWC303, FWC603 & FWC623 Wine Coolers Installation, Use and Maintenance

FWC152, FWC303, FWC603 & FWC623 Wine Coolers Installation, Use and Maintenance FWC152, FWC303, FWC603 & FWC623 Wine Coolers Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E :

More information

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100 HTD High Temperature Non-Cycling Refrigerated Compressed Air Dryers Operation & Maintenance Manual MODELS HTD 21 thru HTD 100 - TABLE OF CONTENTS - 1.0 GENERAL 2 1.1 How to use this manual 1.2 Symbols

More information

USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USE.

USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USE. 65L Dual Zone Fridge USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USE. SAFETY INSTRUCTIONS Please read the user manual and safety instructions carefully before using the appliance.

More information

FWC152 / FWC302 / FWC602 / FWC622 Wine Coolers

FWC152 / FWC302 / FWC602 / FWC622 Wine Coolers FWC152 / FWC302 / FWC602 / FWC622 Wine Coolers Manual for Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949

More information

User and Installation Instructions C6R/75, C6R/100, C6R/105, C6R/125, C6R/130, D6R/100, D6R/125, D5R/100, D5R/125, D3R/100

User and Installation Instructions C6R/75, C6R/100, C6R/105, C6R/125, C6R/130, D6R/100, D6R/125, D5R/100, D5R/125, D3R/100 User and Installation Instructions Seal Refrigerated Merchandisers C6R/75, C6R/100, C6R/105, C6R/125, C6R/130, D6R/100, D6R/125, D5R/100, D5R/125, D3R/100 IS281 ECN3045 Dear Customer, Thank you for purchasing

More information

UNDERCOUNTER LABORATORY FRONT BREATHING REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

UNDERCOUNTER LABORATORY FRONT BREATHING REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions UNDERCOUNTER LABORATORY FRONT BREATHING REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions Please read this manual completely prior to installing and operating this equipment.

More information

TMEF Series. SKOPE Vertical Freezer. User Manual

TMEF Series. SKOPE Vertical Freezer. User Manual TMEF Series SKOPE Vertical Freezer MAN10132 Rev. 1.0 Oct. 2010 TMEF Series SKOPE Vertical Freezer Type: (CAREL ir32 Controller) MAN10132 Rev. 1.0 Oct. 2010 2010 SKOPE Industries Limited. All rights reserved.

More information

Glass Door Merchandiser Refrigerator and Freezer

Glass Door Merchandiser Refrigerator and Freezer Glass Door Merchandiser Refrigerator and Freezer (Swing and Sliding Door ) Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment.

More information

Installation, Operating and Servicing Instructions. Opus 800 Electric Cook & Hold Salamander OE8306

Installation, Operating and Servicing Instructions. Opus 800 Electric Cook & Hold Salamander OE8306 Installation, Operating and Servicing Instructions Opus 800 Electric Cook & Hold Salamander OE8306 Please make a note of your product details for future use: Date Purchased: Model Number: Serial Number:

More information

ER MANUAL FOR YOUR BAUMATIC

ER MANUAL FOR YOUR BAUMATIC BW18BL 50 litre thermoelectric beverage centre BW28BL 70 litre thermoelectric beverage centre ER MANUAL FOR YOUR BAUMATIC BW18BL 50 litre thermoelectric beverage centre BW28BL 70 litre thermoelectric beverage

More information

Solid Door Top Mount Reach-In Freezer

Solid Door Top Mount Reach-In Freezer Solid Door Top Mount Reach-In Freezer Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment. Notify carrier of damage! Inspect

More information

INSTALLATION AND OPERATION INSTRUCTIONS ARCTICPOUR ADVANCED REFRIGERATION TECHNOLOGY

INSTALLATION AND OPERATION INSTRUCTIONS ARCTICPOUR ADVANCED REFRIGERATION TECHNOLOGY INSTALLATION AND OPERATION INSTRUCTIONS ARCTICPOUR ADVANCED REFRIGERATION TECHNOLOGY Table of Contents Dimensional Drawings... 2 Product Description... 5 Installation... 5 Important Safety Warnings...

More information

FWC153, FWC304, FWC604 & FWC624

FWC153, FWC304, FWC604 & FWC624 FWC153, FWC304, FWC604 & FWC624 Wine Coolers Installation, use and maintenance www.cda.eu Important The CDA Group Ltd cannot be held responsible for injuries or losses caused by incorrect use or installation

More information

OWNER S MANUAL HIGH WALL INVERTER. (English) (MSHVD1S SERIES)

OWNER S MANUAL HIGH WALL INVERTER. (English) (MSHVD1S SERIES) OWNER S MANUAL HIGH WALL INVERTER (English) (MSHVD1S SERIES) IMPORTANT As with any product that has moving parts or is subject to wear and tear, it is VERY IMPORTANT that you maintain your air conditioner

More information

4. Proper Loading Only pre-cooled foods should be placed in this unit.

4. Proper Loading Only pre-cooled foods should be placed in this unit. READ THIS PAGE FIRST 1. Howard-McCray would like to thank you for purchasing one of our units. PLEASE READ THIS MANUAL CAREFULLY BEFORE PROCEEDING WITH THE INSTALLATION OR OPERATING OF THIS UNIT. 2. Environment

More information

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS THERMOFILM CONVECTIVE PANEL HEATER Rev C JUL13 INSTALLATION, OPERATION AND MAINTENANCE MANUAL Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS 1. Important Safety Instructions 2. Specification

More information

Operating instructions Page 12

Operating instructions Page 12 Operating instructions Page 12 Refrigerator with explosion-proof interior container Read the operating instructions before switching on for the first time 7082 271-00 LKEXv 910 Disposal notes The appliance

More information

B900/ BME900/ SKOPE Gen2: Two Door Chiller

B900/ BME900/ SKOPE Gen2: Two Door Chiller B900/1100-2 BME900/1100-2 SKOPE Gen2: Two Door Chiller MAN1289 Rev. 5.1 Aug. 2013 B900/1100-2 BME900/1100-2 SKOPE Gen2: Two Door Chiller Type: B900-2 B90BD B1100-2 B39BD/B39SB BME900-2 E90BD BME1100-2

More information