1 MINITOP Refrigerated Self-Service Display underneath Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4 Spare parts page 6 Rue Charles Hermite Z.I. des Sables BP Dombasle sur Meurthe France tel : (+33) fax : (+33) commercial.vcs@vauconsant.com export@vauconsant.com Notice N MM103 - mise à jour le 08 novembre 2006
2 INSTRUCTIONS OF USE AND MAINTENANCE GENERAL POINT Refrigerating components Well : Refrigeration by a ventilated evaporator located in the well. Lighting Lighting by fluorescent tube. Controls High precision control by thermostat with digital display ( to refer to the note of the thermostat provided hereafter ). Started and stop of the regulation by pressure on the key of the keyboard of the thermostat. Lighting: started and stop of lighting by pressure on the key of the keyboard of the thermostat. Control devices placed on a control board. Protection By main power fuse holder. INSTALLATION To set up the drop-in unit Settle the black neoprene watertight joint on the perimeter of the drop-in unit before the definitive installation. To embed the well ventilated in cutting envisaged. Electric connection Before plugging in the unit, control imperatively the voltage rating : it should be the same voltage as indicated on the unit. The electric power line providing the refrigerated unit with electricity should be protected by a differential circuit breaker located on the main electric distribution panel. To connect the incoming line to the fuse holder located in the electric box. To connect the plug of the self evaporating tray. Compressor connection ( when the compressor group is not supplied) To connect the refrigerating circuit, in accordance with the refrigerating diagram, provided hereafter. To set up the self evaporating tray The self evaporating tray must be placed under the unit. The installation twist of the self evaporating tray must be connected to the plug of the electric box, according the standard of unit, the twist of the self evaporating tray can be situed in the face or in the back of the unit. Astainless steel sheet deflector located in the self evaporating tray, allow to direct the water vapour. The sheet must be located in the middle of the self evaporating tray ( the same distance in each side). The deflector must be located to have the good direction of the inclination, like described in the following diagram. HOW TO USE To put into service Powering up the unit two hours before usage. Press the key of the thermostat When the thermostat is activated, the power unit starts running a minute later (safety timeout) to supply power. The thermostat is adjusted in the factory after testing. When the desired temperature is obtained, the power unit automatically turns off. Press the key of the thermostat to turn off the regulation of the unit. Lighting Press the key lighting. Adjusting the thermostat Refer to the manual for details. of the thermostat to turn on or turn off the Automatic defrosting This function is programmed in the thermostat/ Adjusted in the factory: the defrosting engages every hour throughout one ten maximum minute. To modify the adjustment, refer the manual of the thermostat Cleaning To be performed when the unit is shut down (the unit is turned off). Once a day, wash the top, the refrigerated well and the external sides of the unit. Use a sponge moistened with a soapy water or special cleaning products to clean the stainless steel. Rinse off with water. Dry preferably with lint-free cotton cloths. Do not use floor cleaning products or acids, even diluted, chlorinated or scouring products, which may cause corrosion to stainless steel. Do not use any abrasive products (steel wool, etc ). Do not clean the refrigerated unit by spraying with water, using a soap gun, or under high pressure jets. MAINTENANCE The installer should check all the electric connections during the initial start up of the unit (and then once a year). Clean the condenser every six months. Grease the condenser blower shaft once a year. deflector 2
3 ELECTRIC DIAGRAM REFRIGERATING DIAGRAM CAPTION DIAGRAMS B Ballast Rd Defrost heating element C Compressor Sf Starter Ca Capillary Sn Level probe Cd Condensor St Atmosphere temperature probe D Relief valve T Thermostat XW60L Dh Drier Tb Safety thermostat for self evaporating tray E Evaporator Tf Fluorescent tub Kb Self evaporating tray relay V Well ventilator Kd Defrost relay Vc Condensor fan Q Fuse holder Vl Liquid sign Rb Self-evaporating tray heating element Vm Manual valve 3
4 MANUAL OF THERMOSTAT XW60L Please read this manual before using 1.AVERTISSEMENT Warning: disconnect all electrical connections before any kind of maintenance. The instrument must not be opened. In case of failure or faulty operation send the instrument back to the distributor or to with a detailed description of the fault. 2.DESCRIPTION Model XW60L is microprocessor based controllers suitable for applications on medium or low temperature refrigerating units. They are provided with 4 relay outputs to control compressor, defrost, fans for the evaporator and the lights. They are also provided with 2 NTC probe inputs, for temperature control, the second for end defrost temperature control. The regulation is performed according to the temperature measured by the thermostat probe with a positive differential from the set point: if the temperature increases and reaches set point plus differential the compressor is started and then turned off when the temperature reaches the set point value again. 3.KEYBOARD To display and modify target set point; in programming mode it selects a parameter or confirm an operation. By holding it pressed for 3s when max or min temperature is displayed it will be erased. To see the max. stored temperature; in programming mode it browses the parameter codes or increases the displayed value. By holding it pressed for 3s the fast freezing cycle is started. To see the min stored temperature; in programming mode it browses the parameter codes or decreases the displayed value. By holding it pressed for 3s the defrost is started. Switch ON and OFF the light of the cold-room. Switch ON and OFF the instrument. KEY COMBINATIONS + To lock and unlock the keyboard. + To enter the programming mode. + exit the programming mode. 3.1 To lock and unlock the keyboard HOW TO LOCK THE KEYBOARD Keep the and the keys together for more than 3 s. The "POF" message will be displayed and the keyboard is locked. At this point it is only possible the viewing of the set point or the MAX or Min temperature stored and to switch ON and OFF the light, the auxilary output and the instrument. HOW TO UNLOCK THE KEYBOARD Keep the and the keys pressed together for more than 3 s. The "POn" message will be displayed and the keyboard is unlocked. 3.2 Meaning of the LED Each LED function is described in the following table : LED MODE FONCTION ON The compressor is running Flashing Programmation phase ( flashing with Anti-short cycle delay enabled ) ON The fan is running. Flashing Programmation phase ( flashing with ) ON The defrost is enabled. Flashing Drip time in progress ON The fast freezing cycle is enable Alarm signal ON In Pr2 indicates that the parameter is also present in Pr1 ON The light is on 3.3 How to see the min temperature Press and release this key. The Lo message will be displayed followed by the minimum temperature recorded. By pressing this key or waiting for 5s the normal display will be restored. 3.4 How to see the max temperature Press and release this key. The Hi message will be displayed followed by the maximum temperature recorded. By pressing this key or waiting for 5s the normal display will be restored. 3.5 How to reset the max and min temperature recorded To reset the stored temperature, when max or min temperature is displayed, press SET key until rst label starts blinking. N.B. : After the installation RESET the temperature stored. 3.6 How to see and modify the set point Push and immediately release the SET key: the display will show the Set point value. The SET LED start blinking. To change the Set value push the or arrows within 10s. To memorise the new set point value push the SET key again or wait 10s. 4
5 3.7 To start a manual defrost Push the DEF key for more than 2 seconds and a manual defrost will start. 3.8 To enter in parameters list Pr1 To enter the parameter list Pr1 (user accessible parameters) operate as follows: Enter the Programming mode by pressing the Set and DOWN key for few seconds ( and start blinking). The instrument will show the first parameter present in Pr To enter in parameters list Pr2 To reach the parameters present in "Pr2" (parameters accessible to the technicians), please contact, which will deliver you the secret code making it possible to reach these parameters. ALARM SIGNALS The message is displayed until the condition is recovery. All the messages are showed alternating with the room temperature except for the P1 which is flashing. To reset the EE and restart the normal functioning press any key, the rst message is displayed for about 3s. 4.1 EE The instruments are provided with an internal check for the data integrity. Alarm EE flashes when a failure in the memory data occurs. In such cases the output is enabled. 4.2 Alarm recovery Probe s P1 (probe1 faulty), P2 ; they automatically stop 10s after the probe restarts normal operation. Check connections before replacing the probe. Temperature s HA and LA automatically stop as soon as the thermostat temperature returns to normal values or when the defrost starts. Messag e "P1" Cause Thermostat probe failure Output Alarm output ON; Compressor output according to parameters COn and COF Alarm output ON; Other Alarm output ON; Other "P2" Evaporator probe failure "HA" Maximum temperature "LA" Minimum Alarm output ON; Other temperature "EE" Data or memory Alarm output ON; Other failure "da" Door switch Alarm output ON; Other "EAL" External Alarm output ON; Other "BAL" Serious external Alarm output ON; Other outputs OFF "PAL" Pressure switch Alarm output ON; Other outputs OFF 5. PARAMETERS PROGRAMS IN FACTORY Parameter Name Default value following the length of the unit Set Set point Hy Differential AC Anti-short cycle delay res Resolution (integer/decimal point) de de de de tdf Defrost type re re re re dte Defrost termination temperature IdF Interval between defrost cycles MdF (Maximum) length for defrost ALU MAXIMUM temperature ALL Minimum temperature ot Thermostat probe calibration P2P Evaporator probe presence n n n n Adr Address series (unused) P2r Access parameter list ( read only) 5
6 Code SPARE PARTS Item description Length of the unit Accessories Stainless steel base 55 mm diameter with attachment plate and jack screw X X X X Door guide for self-service glass display case MINITOP 2 and 3 levels X X X X Sliding doors for self service glass display case MINITOP 2 levels Sliding door freeze soaked thickness 6 mm, 350 x 452 X Sliding door freeze soaked thickness 6 mm, 455 x 452 X Sliding door freeze soaked thickness 6 mm, 620 x 452 X Sliding door freeze soaked thickness 6 mm, 742 x 452 X Sliding doors for self service glass display case MINITOP 3 levels Sliding door freeze soaked thickness 6 mm, 350 x 602 X Sliding door freeze soaked thickness 6 mm, 455 x 602 X Sliding door freeze soaked thickness 6 mm, 620 x 602 X Sliding door freeze soaked thickness 6 mm, 742 x 602 X Shelves for self service glass display case MINITOP 2 and 3 levels Shelf freeze soaked thickness 10 mm, 845 x 360 X Shelf freeze soaked thickness 10 mm, 1060 x 360 X Shelf freeze soaked thickness 10 mm, 1385 x 360 X Shelf freeze soaked thickness 10 mm, 1710 x 360 X Lateral glass for self-service glass display case MINITOP Lateral glass thickness 6 mm for self-service glass display case 2 levels X X X X Lateral glass thickness 6 mm for self-service glass display case 3 levels X X X X Option self-evaporating tray Self-evaporating tray heating element X X X X Electric equipment Ventilator for evaporator 119 x 119 x 38, 230 V X X X X Bipolar relay X X X X Thermostat WING XW60L X X X X Refrigerating equipment Evaporator length 600 X Evaporator length 920 X Evaporator length 1250 X Evaporator length 1570 X Group condensation CAE 9460 ZMHR X Group condensation CAE 9480 ZMHR X Group condensation CAJ 9510 ZMHR X Group condensation CAJ 9513 ZMHR X Defrost heating element Defrost heating element 570 mm 450 W X Defrost heating element 890 mm 675 W X Defrost heating element 1220 mm 900 W X Defrost heating element 1540 mm 1125 W X Lighting Fluorescent tub length 590 power 18 W X Fluorescent tub length 895 power 30 W X Fluorescent tub length 1200 power 36 W X Fluorescent tub length 1500 power 58 W X Ballast for fluorescent tub 18 W X Ballast for fluorescent tub 30 and 36 W X X Ballast for fluorescent tub 58 W X 6
OMNITOP Refrigerated Display with Ventilated Cooling
OMNITOP Refrigerated Display with Ventilated Cooling Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4 Spare parts page 6 Rue Charles
More informationInstructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4 Spare parts page 6
INOUK Upright refrigerated display Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4 Spare parts page 6 Rue Charles Hermite Z.I. des
More informationREVERSO. Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4-6 Spare parts page 7
REVERSO Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4-6 Spare parts page 7 Rue Charles Hermite Z.I. des Sables BP 59 54110 Dombasle
More informationDixell Installing and Operating Instructions release 7.0
XR160C - XR160D - XR170C - XR170D - XR162C - XR172C CONTENTS 1. GENERAL WARNING 2 1.1 Please read before using this manual 2 1.2 Safety Precautions 2 2. GENERAL DESCRIPTION 2 3. CONTROLLING LOADS 2 3.1
More informationdixel Installing and Operating Instructions PRELIMINAY
. GENERAL WARNING XW6K - AFV PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument for easy and quick reference. The instrument shall not be used
More informationXR60C ,QVWDOOLQJDQG2SHUDWLQJ,QVWUXFWLRQV. Digital controller with defrost and fans management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS
Digital controller with defrost and fans management XR60C CONTENTS 1. GENERAL WARNING 1 2. GENERAL DESCRIPTION 1 3. CONTROLLING LOADS 1 4. FRONT PANEL COMMANDS 1 5. TEMPERATURE ALARM AND ITS DURATION RECORDING
More informationXWA11V. Walk-In Temp / Door /Alarm / Light Module
XWA11V Walk-In Temp / Door /Alarm / Light Module 1. GENERAL DESCRIPTION Model XWA11V, 100x64 mm format, is a microprocessor-based controller, suitable for temperature monitoring and alarming in a walk-in
More informationXWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring
XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring 1. GENERAL DESCRIPTION Model XWA11V-KIT, 100x64 mm format, is a microprocessor based light and alarm management controller,
More informationCommercial Refrigerator Service Manual
Commercial Refrigerator Service Manual SOLID DOOR TOP MOUNT REACH-IN PTM49R Please read this manual completely before attempting to install or operate this equipment. TABLE OF CONTENTS 1. FEATURE CHART
More informationOperating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module
XWA11V Walk-In Temp / Door /Alarm / Light Module 1. GENERAL DESCRIPTION Model XWA11V, 100x64 mm format, is a microprocessor-based controller, suitable for temperature monitoring and alarming in a walk-in
More informationOPERATING INSTRUCTIONS ULTF 80 / 220 / 320 / 420
OPERATING INSTRUCTIONS ULTF 80 / 220 / 320 / 420 INDEX........................................................... PAGE Before using the appliance...............................................................
More informationDigital Controller XR70CX. Operating Manual. 5/10 Rev. B
Digital Controller XR70CX Operating Manual 5/10 Rev. B 139734 Contents General Warnings 3 General Description 3 Regulation 3 Defrost 3 Fans 4 Front Panel Commands 4 Parameters 6 Installation and Mounting
More informationCommercial Freezer Service Manual
Commercial Freezer Service Manual SOLID DOOR TOP MOUNT REACH-IN PTM49F Please read this manual completely before attempting to install or operate this equipment. TABLE OF CONTENTS 1. FEATURE CHART 1-1.
More informationdixel Installing and Operating Instructions
XW20K AND T620 V620 CX620 1. GENERAL WARNING PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument for easy and quick reference. The instrument
More informationOperating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring
XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring 1. GENERAL DESCRIPTION Model XWA11V-KIT, 100x64 mm format, is a microprocessor based light and alarm management controller,
More informationTop Mount Full Length Swinging Doors
Top Mount Full Length Swinging Doors *Shown in FT103SD3 model Model FT77SD FT103SD3 FT138SD Width 77 103 138½ Depth 32 32 32 Height 86 ½ 86 ½ 86 ½ Volume/cu. Ft. 77 103 140 Doors 3 3 4 Door Size 23 x 66
More informationOWNER S MANUAL STAINLESS STEEL REACH-IN SERIES. Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ATF2 ATR2
OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ABF1 ABF2 ABF3 ABR1 ABR2 ABR3 ABF1 ABR1 ATF2 ATR2 ABF3 ABR3 Please read the manual carefully and follow all instructions.
More informationXH260L XH260V. Dixell Operating instructions TEMPERATURE AND HUMIDITY CONTROLLER 1. GENERAL WARNING
XH260L XH260V TEMPERATURE AND HUMIDITY CTROLLER 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument for easy and quick
More informationRefrigerated Milk Drawer
Refrigerated Milk Drawer Copyright Septamber 2016 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any
More informationUser Instructions Lab* Frost. Ultra Low Temperature Freezers Model LAB
User Instructions Lab* Frost Ultra Low Temperature Freezers Model LAB SAFETY INFORMATIONS The LAB freezers contains environmentally friendly but flammable refrigerants. It means danger of explosion if
More informationXW40K AND T620T - T620 V620 CX620
XW40K AND T620T - T620 V620 CX620 1 GENERAL WARNING... 1 2 GENERAL DESCRIPTI... 1 3 CTROLLING LOADS... 1 4 SPECIAL FUNCTIS... 1 5 KEYBOARDS... 1 6 AUTOMATIC KEYBOARD LOCK (LY FOR T620T)... 2 7 CTROLLER
More informationXR60CX. Installation and Operating Instructions. Digital controller with defrost and fans management. + + To return to the room temperature display.
Digital controller with defrost and fans management XR60CX CTENTS 1. GENERAL WARNING 1 2. GENERAL DESCRIPTI 1 3. CTROLLING LOADS 1 4. FRT PANEL COMMANDS 1 5. MAX & MIN TEMPERATURE MEMORIZATI 1 6. MAIN
More informationRefrigerated air dryers
Refrigerated air dryers OPERATING AND MAINTENANCE MANUAL Original instructions 38178800319 OPERATING AND MAINTENANCE MANUAL - Contents 1 CONTENTS CONTENTS... 1 Chapter 1 IDRY ELECTRONIC CONTROLLER...
More informationRefrigerated Cabinets Square Format
Refrigerated Cabinets Square Format Copyright December 2017, Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted
More informationElectronic Controller For Refrigeration XLR130 XLR170
Electronic Controller For Refrigeration XLR130 XLR170 Instructions Manual COOL OOLMATE XLR130C XLR170C INDEX 1. GENERAL WARNING 3 2. GENERAL DESCRIPTION 3 3. CONTROLLING LOADS 3 4. KEYBOARD 5 5. REAL TIME
More informationRead and save these instructions
www.winemate.com Wine Cooling System WM-1500HZD, WM-2500HZD WM-3500HZD, WM-4500HZD WM-6500HZD, WM-8500HZD Installation, Use & Care Manual www.vinotemp.com Read and save these instructions Important Safety
More informationdixel Installing and Operating Instructions 1592027050 Digital controller for medium-low temperature refrigeration applications XW60L 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual
More information1 NORMS AND REGULATIONS Guarantee norms: Environmental notes: Identification:... 15
Index 1 NORMS AND REGULATIONS... 15 1.1 Guarantee norms:... 15 1.2 Environmental notes:... 15 1.3 Identification:... 15 2 INSTALLATION... 16 2.1 Lifting and Movement:... 16 2.2 Positioning:... 16 2.3 Environmental
More informationInline GN Series Refrigerated Well
Inline GN Series Refrigerated Well Copyright June 2017 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in
More informationTelephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A
Blast Chiller / Freezer Instruction Manual Model DN492-A DN494-A Safety Tips Position on a flat, stable surface. A service agent/qualified technician should carry out installation and any repairs if required.
More informationXH50P - XH55P Temperature/relative humidity probe with RS485 serial line
XH50P - XH55P Temperature/relative humidity probe with RS485 serial line 1. GENERAL WARNINGS 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument
More informationUpright Chiller & Freezer Service, Installation and Care Manual
Upright Chiller & Freezer Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment. Notify carrier of damage! Inspect all components
More informationRead and save these instructions
www.winemate.com Wine Cooling System WM-1500HZD, WM-2500HZD WM-3500HZD, WM-4500HZD WM-6500HZD, WM-8500HZD Installation, Use & Care Manual www.vinotemp.com Read and save these instructions Important Safety
More informationRefrigerated Cabinets
Refrigerated Cabinets Copyright June 2017 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or
More informationOpen Front Food & Drinks Cabinet AS/NZS
Open Front Food & Drinks Cabinet AS/NZS Copyright November 2017 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted
More informationRefrigerated Cabinets Curved Format
Refrigerated Cabinets Curved Format Copyright August 2018, Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted
More informationTOQUE BLANCHE GRANDE CARTE
REFRIGERATED BASES TOQUE BLANCHE GRANDE CARTE MAINTENANCE MANUAL MANUFACTURERS SPECIFICATION BONNET GRANDE CUISINE Rue des Frères Lumière - Z.I. Mitry Compans 77292 MITRY MORY cedex Tél. 01 60 93 70 00
More informationFood & Beverage Cabinet
Food & Beverage Cabinet Copyright June 2017 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or
More informationUNIVERSAL R V3.0. NEW FEATURES on the V3.0
UNIVERSAL R V3.0 NEW FEATURES on the V3.0 HEATING : As well as cooling, the Universal-R can now be used to control heating applications up to +105c, using the NTC probes supplied in box. For temperatures
More informationRev 0 09-FEB XR75CX Digital Controller for Medium-Low Temperature Refrigeration Applications Installation and Operation Manual
026-1210 Rev 0 09-FEB-2011 XR75CX Digital Controller for Medium-Low Temperature Refrigeration Applications Installation and Operation Manual Retail Solutions 3240 Town Point Drive NW Suite 100 Kennesaw,
More informationTime KEY COMBINATIONS: + To lock & unlock the keyboard. + To enter in programming mode. + To return to the room temperature display. 4.
Digital controller for medium-low temperature refrigeration applications XW40L 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the
More informationRefrigerated Cabinets Curved Format
Refrigerated Cabinets Curved Format Copyright August 2018 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted
More informationCeiling Split Cooling System Installation, Operation & Care Manual WM-2500SSD WM-4500SSD WM-6500SSD WM-8500SSD
www.winemate.com Ceiling Split Cooling System Installation, Operation & Care Manual WM-2500SSD WM-4500SSD WM-6500SSD WM-8500SSD www.vinotemp.com Read and save these instructions Important Safety Information
More informationRead and save these instructions
www.winemate.com Customizable Wine Cooling System WM-4510HZD WM-6510HZD WM-8510HZD Installation, Use & Care Manual www.vinotemp.com Read and save these instructions Important Safety Information NOTES:
More informationXB570L XB570L. dixel Operating and Instructions Manual BLAST CHILLER - QUICK CHILL AND HOLD FUNCTION
XB570L BLAST CHILLER - QUICK CHILL AND HOLD FUNCTION Contents 1. General warning 1 2. General Features 1 3. Mounting & Installation 1 4. Electrical Connections 1 5. Connections 1 6. Frontal panel 1 7.
More informationXW70L. Digital controller for medium-low temperature refrigeration applications AUX 1. GENERAL WARNING 2. GENERAL DESCRIPTION 3.
Digital controller for medium-low temperature refrigeration applications XW70L 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the
More informationRead and save these instructions
Split Ceiling-Mounted Cooling System Operation Care Installation Manual WM-2500SSD WM-2500SSD-LA WM-4500SSD WM-4500SSD-LA WM-6500SSD WM-6500SSD-LA WM-8500SSD WM-8500SSD-LA WM-12000SSD WM-12000SSD-LA www.vinotemp.com
More informationTelephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A
Blast Chiller / Freezer Instruction Manual Model DN492-A DN494-A 1 Safety Tips Position on a flat, stable surface. A service agent/qualified technician should carry out installation and any repairs if
More informationSf2+HF2 Sf2 Sf1 + Hf1 Sf1. 1 ON Fan1 enabled (only for XC30CX) 2 ON Fans enabled (only for XC30CX) kpa. Time
Digital controller for CDU management XC10CX and XC30CX 1. GENERAL WARNING... 1 2. GENERAL DESCRIPTION... 1 3. CONTROLLING LOADS... 1 4. FRONT PANEL COMMANDS... 1 5. OTHER FUNCTIONS... 1 6. MAIN INTERFACE...
More informationAIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner GUARDIAN SERIES KNA4C9DP47L-1
GUARDIAN SERIES KNA4C9DP47L-1 Keep This Manual With Air Conditioner Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents AIR CONDITIONER
More informationXC10CX and XC30CX. Digital controller for CDU management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS 2. GENERAL DESCRIPTION
Digital controller for CDU management XC10CX and XC30CX 1. GENERAL WARNING... 1 2. GENERAL DESCRIPTION... 1 3. CONTROLLING LOADS... 1 4. FRONT PANEL COMMANDS... 1 5. OTHER FUNCTIONS... 1 6. MAIN INTERFACE...
More informationRead and save these instructions
Split Water-Cooled Through-Ceiling Cooling System Operation Care Installation Manual WM-2500SSOWC WM-4500SSOWC www.vinotemp.com Read and save these instructions Vinotemp International Corp 17631 S Susana
More informationBeverage Air IMPORTANT
Beverage Air IMPORTANT INFORMATION FOR CT96 MODEL This cooler has passed the QUALITY CONTROL INSPECTION And meets the high standards for Beverage-Air Refrigeration products IMPORTANT PLEASE RETAIN FOR
More informationCIAO series ICE CREAM DISPLAY CABINET. Maintenance And Use Manual
ICE CREAM DISPLAY CABINET CIAO series Maintenance And Use Manual Mail: PO Box 18542, Greensboro, NC 27419 Street: 5C Wendy Ct, Greensboro, NC 27409 Phone: 336-856-2919 Fax: 336-217-8838 Email: sales@advancedgourmet.com
More informationRead and save these instructions
Split Water-Cooled Central-Ducted Cooling System Operation Care Installation Manual WM-2500SSHWC WM-4500SSHWC WM-6500SSHWC WM-8500SSHWC WM-12000SSHWC www.vinotemp.com Read and save these instructions Vinotemp
More informationSf2+HF2 Sf2 Sf1 + Hf1 Sf1. DLT Prb. Ground
Digital controller for CDU management XC30CX 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument for easy and quick reference.
More informationSolid Door Top Mount Reach-In Freezer
Solid Door Top Mount Reach-In Freezer Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment. Notify carrier of damage! Inspect
More informationIKEA USA Refrigerated Cabinets
IKEA USA Refrigerated Cabinets Copyright March 2017 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any
More informationAIR COOLED CHILLERS MODELS: MPCA0005 MPCA0150 INSTALLATION, OPERATION, AND MAINTENANCE MANUAL
MOTIVAIR COOLING SOLUTIONS AIR COOLED CHILLERS MODELS: MPCA0005 MPCA0150 INSTALLATION, OPERATION, AND MAINTENANCE MANUAL This chiller has been factory run tested to the specified water pressure *****DO
More informationRead and save these instructions
Split Through-Ceiling Cooling System Operation Care Installation Manual WM-2500SSO WM-2500SSO-LA WM-4500SSO WM-4500SSO-LA www.vinotemp.com Read and save these instructions Vinotemp International Corp 17631
More informationXH340L-V TEMPERATURE AND HUMIDITY CONTROLLER FOR SEASONING-MATURING CABINETS 1. GENERAL WARNING
XH340L-V TEMPERATURE AND HUMIDITY CTROLLER FOR SEASING-MATURING CABINETS 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument
More informationCAREL IR33+ CONTROLLER
CAREL IR33+ CONTROLLER Programming Instructions The Carel IR33+ controller has a two-level menu system for programming the operation of the case; Level 1 and Level 2 program settings. Unlike IR33, the
More informationXR77CX. dixel Installing and Operating Instructions Digital controller for medium-low temperature refrigeration applications
Digital controller for medium-low temperature refrigeration applications XR77CX 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the
More informationWATER HEATER ELECTRONIC CONTROLLER USER MANUAL
WATER HEATER ELECTRONIC CONTROLLER USER MANUAL UPPER LED READOUT LED ICONS LOWER LED READOUT PVI INDUSTRIES, LLC - Fort Worth, Texas 76111 - Web www.pvi.com - Phone 1-800-433-5654 Page 1 / 7 PV500-40 03/17
More informationINSTALLATION AND OPERATING MANUAL
INSTALLATION AND OPERATING MANUAL Refrigerated Cases with Air-Over Displays Refrigerated High Profile Grab-N-Go FOR PARTS & SERVICE Contact: Piper Products, Inc. Phone: (800) 544-3057 Ask for Service Department
More informationSplit Wall-Recessed Cooling System Operation Care Installation Manual
Split Wall-Recessed Cooling System Operation Care Installation Manual WM-2520SSW 2520SSW-LA WM-4520SSW 4520SSW-LA www.vinotemp.com Read and save these instructions Vinotemp International Corp 17631 S Susana
More informationUSER MANUAL. Read this manual thoroughly prior to equipment set-up, operation or maintenance. Model
USER MANUAL Read this manual thoroughly prior to equipment set-up, operation or maintenance. Model 243006 NEXEL Merchandiser Refrigerator 2 Door, 53.1''W x 31.9''D x 84.4"H (with casters) For questions,
More informationREF Series Undercounter Refrigerator
REF Series Undercounter Refrigerator Order parts online www.follettice.com Installation, Operation and Service Manual Serial numbers B59000 to C4584 Following installation, please forward this manual to
More informationINSTALLATION AND OPERATING MANUAL
INSTALLATION AND OPERATING MANUAL Refrigerated Island Merchandiser FOR PARTS & SERVICE Contact: Piper Products, Inc. Phone: (800) 544-3057 Ask for Service Department IMPORTANT! This manual contains important
More informationINSTALLATION AND OPERATING MANUAL
INSTALLATION AND OPERATING MANUAL Refrigerated Merchandisers with Air-Over Displays Refrigerated Low-Profile Mobile Merchandiser Refrigerated High-Profile Mobile Merchandiser Refrigerated Grab-N-Go Merchandiser
More informationSandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator
Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment. Notify
More informationGlass Door Merchandiser Refrigerator and Freezer
Glass Door Merchandiser Refrigerator and Freezer (Swing and Sliding Door ) Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment.
More informationInstruction Manual for HX-DX and HX-DXHP Heat Exchangers 3 / 2017
Instruction Manual for HX-DX and HX-DXHP Heat Exchangers 3 / 2017 Model No. HX-36DX Model No. HX-120DX Check packing slip and product to see if they match. If not, contact Aqua Logic immediately!! Important:
More informationRev 1 24-MAY XR75CX Digital Controller for Medium-Low Temperature Refrigeration Applications Installation and Operation Manual
026-1210 Rev 1 24-MAY-2012 XR75CX Digital Controller for Medium-Low Temperature Refrigeration Applications Installation and Operation Manual Retail Solutions 3240 Town Point Drive NW Suite 100 Kennesaw,
More informationSide-by-side combined refrigerator-freezer
REPAIR INSTTRUCTTI I IONS Side-by-side combined refrigerator-freezer 1 SAFETY... 2 4.1 Electronic controller... 8 1.1 Safety instructions... 2 1.2 Repair instructions... 2 2 INSTALLATION... 3 3 OPERATION...
More informationGlass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69
Commercial Refrigerator And Freezer User s Manual Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69 12/2015 Please read the manual thoroughly prior to equipment
More informationChef Base Refrigerators
Chef Base Refrigerators Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment. Notify carrier of damage! Inspect all components
More informationREFRIGERATED ROOM & TEMPERATURE/HUMIDITY CONTROLLERS
SECTION INDEX FUNCTIONS MODELS XLR100 COOL MATE - NT, MT AND LT APPLICATIONS - SERIAL OUTPUT Advanced multifunction controllers for NT refrigerated rooms XLR130 Advanced multifunction controllers for MT
More informationRead and save these instructions
Split Central-Ducted Cooling System Operation Care Installation Manual WM-12000SSH WM-12000SSH-LA www.vinotemp.com Read and save these instructions Vinotemp International Corp 17631 S Susana Road Rancho
More informationCOMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS OPERATING INSTRUCTIONS
COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS OPERATING INSTRUCTIONS CE COMMERCIAL REFRIGERATORS Model - S.N.: Volt: 220 Hz: 50 Amps: Watt: Watt (heating element): Fuse Amps: Refrigerant: R gr: Working
More informationWH7016E Thermostat Product Manual
WH7016E Thermostat Product Manual Shenzhen Willhi Electronics Co., Ltd. Tel :0755-29539385 Fax :86-0755 -2953 9395 Technical support: Engineer Tian 1 Installation opening size: 2 Wiring diagram: 1 2 3L
More informationUSER MANUAL. Read manual thoroughly prior to equipment set-up, operation or maintenance. Model Model
USER MANUAL Read manual thoroughly prior to equipment set-up, operation or maintenance. Model 243009 Model 243010 NEXEL 1-Door Reach-in Freezer NEXEL 2-Door Reach-in Freezer For questions, please contact
More informationAIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner INTREPID SERIES K2A6C30EP56TR-4
INTREPID SERIES K2A6C30EP56TR-4 Keep This Manual With Air Conditioner Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents AIR CONDITIONER
More informationFX BLAST CHILLER ISO ISO 9001
FX BLAST CHILLER ISO 14001 ISO 9001 Contents Environmental Management Policy 1 Disposal Requirements 1 Cabinet description 2 Controller Description Controller Operation 2 to 3 Alarms & Warnings 4 Parameter
More informationINSTALLATION AND OPERATING MANUAL
INSTALLATION AND OPERATING MANUAL Salad Bars Olive Bars Food Prep Cases Refrigerated Cases with Air-Over Displays Refrigerated Cases with Coppered Cold Well Displays Cases with Under-Counter Refrigerators
More informationAIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner TRIMLINE KA6C4NP28L
TRIMLINE KA6C4NP28L Keep This Manual With Air Conditioner Find additional information on this model at kooltronic.com, or use the Technical Documents QR code below. Technical Documents AIR CONDITIONER
More informationLabel Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature
EVCO S.p.A. EV3B24 Data sheet ver. 1.0 Code 1043B24E104 Page 1 of 6 PT 12/15 EV3B24 Basic controller for low temperature bottle coolers, cabinets, refrigerated cabinets, tables and pizza counters, with
More informationSSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB
H SSGB Technical Data Sheet P/N 3018921_E EPH Certified to NSF-7 January 2018 F A C D E A G B We reserve the right to change or revise specifications and product design in connection with any feature of
More informationPROGRAMMING MANUAL. CM (Micro v. 1.0)
PROGRAMMING MANUAL CM 42-432-632-232-95-255-325 (Micro v..) CONTENTS: MAIN FEATURES... 3. GENERAL... 3.2 USER INTERFACE... 3.2. KEYS (LOCATED ON THE MEMBRANE)... 3.2.2 SUMMARY OF FUNCTIONS ACTIVATED BY
More informationINSTALLATION and OPERATION INSTRUCTIONS
INSTALLATION and OPERATION INSTRUCTIONS 4400 Series Power Paks MODEL NOS. 4400 Series 4404 4420 4410 4404W 4414 4410W 4414-230 4414W c IMPORTANT INFORMATION To register your product, visit our web site
More informationCDC-R & CDC-D BAKERY MULTI-DECK MERCHANDISER I N S TA L L AT I O N & O P E R AT I O N S M A N UA L. Table of Contents
MULTI-DECK MERCHANDISER I N S TA L L AT I O N & O P E R AT I O N S M A N UA L CDC-R & CDC-D BAKERY Table of Contents Energy Data & Case Dimensions...2-5 Pre-Power Checklist...13 General Information...
More informationAIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner. GUARDIAN SERIES K3NA4C3DP24L 480 Volt 1-PHASE
GUARDIAN SERIES K3NA4C3DP24L 480 Volt 1-PHASE Keep This Manual With Air Conditioner Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents
More informationAIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner GUARDIAN SERIES K2NA6C14DP50L
GUARDIAN SERIES K2NA6C14DP50L Keep This Manual With Air Conditioner Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents AIR CONDITIONER
More informationAIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner 480 VOLT GUARDIAN SERIES K3NA6C18DP53L
480 VOLT GUARDIAN SERIES K3NA6C18DP53L Keep This Manual With Air Conditioner Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents
More informationRefrigerator KE T
Refrigerator KE 680-1-3T Service Manual: H8-74-07 Responsible: U. Laarmann KÜPPERSBUSCH HAUSGERÄTE AG E-mail: uwe.laarmann@kueppersbusch.de Tel.: (0209) 401-732 Customer Service Fax: (0209) 401-743 Postfach
More informationAIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner 480 VOLT GUARDIAN SERIES K3NA6C26DP60L
480 VOLT GUARDIAN SERIES K3NA6C26DP60L Keep This Manual With Air Conditioner Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents
More informationAIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner SLIMKOOL SERIES K_NA4C4SP28L
SLIMKOOL SERIES K_NA4C4SP28L Keep This Manual With Air Conditioner Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents AIR CONDITIONER
More informationUser Guide ems25plus. Page 1. Normal operation. Product interface
Page 1 Product interface rmal operation During normal operation, EMS controllers display the information below. Assuming the product temperature is correct when the outlet is open, this means that the
More informationUser Manual. Commercial Refrigerator And Freezer User s Manual
User Manual Commercial Refrigerator And Freezer User s Manual 05/2016 Reach-in Refrigerator And Freezer Refrigerator model: CFD-1RR, CFD-2RR, CFD-3RR Freezer model: CFD-1FF, CFD-2FF, CFD-3FF Glass Door
More informationLevControl LC PLUS OPERATING INSTRUCTIONS ALL OUR SYSTEMS COMPLY WITH DIRECTIVE 73/23 EEC - 89/336. Cod /0-12/97
LevControl LC PLUS ALL OUR SYSTEMS COMPLY WITH DIRECTIVE 73/23 EEC - 89/336 OPERATING INSTRUCTIONS Cod. 71503277/0-12/97 WARNING!!! THE OPERATIONS LISTED BELOW AND THOSE MARKED BY THIS SYMBOL ARE STRICTLY
More information