REVERSO. Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4-6 Spare parts page 7

Size: px
Start display at page:

Download "REVERSO. Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4-6 Spare parts page 7"

Transcription

1 REVERSO Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4-6 Spare parts page 7 Rue Charles Hermite Z.I. des Sables BP Dombasle sur Meurthe France tel : (+33) fax : (+33) commercial.vcs@vauconsant.com export@vauconsant.com 1

2 INSTRUCTION OF USE AND MAINTENANCE GENERAL POINT Refrigerating components Well : Refrigeration by a ventilated evaporator located in the well. Well bain-marie pulsated air One or two stainless steel resistance shield with blades, located in a box. Option crawl heating halogen Heating and lighting by halogen lights. Lighting Lighting by fluorescent tube. Controls A 4 positions switch to select the function mode desired. Froid : High precision control by thermostat Dixell XR40 with digital display ( to refer to the note of the thermostat provided hereafter ). Chaud : High precision control by thermostat Dixell XT110C with digital display ( to refer to the note of the thermostat provided hereafter ). Halogen lamp : Variator Fluorescent tub : a switch on/off Controls located on the control s panel Protection By main power fuse holder. INSTALLATION To set up the drop-in unit Settle the black neoprene watertight joint on the perimeter of the drop-in unit before the definitive installation. To embed the well ventilated in cutting envisaged. Electric connection Before plugging in the unit, control imperatively the voltage rating : it should be the same voltage as indicated on the unit. The electric power line providing the refrigerated unit with electricity should be protected by a differential circuit breaker located on the main electric distribution panel. To connect the incoming line to the fuse holder located in the electric box. To connect the plug of the self evaporating tray. Compressor connection To connect the refrigerating circuit, in accordance with the refrigerating diagram, provided hereafter. To connect the two strikers by tighten with adequate spanner, the tightening became hard during the impact of the strikers, the tightening must be continued to have a good airtightness. A wrong tighten of the strikers can generate a flight of the refrigerating gas and failure of the equipment. It is recommended to check the airtightness of the strikers with detector of flight, after the tighten of the strikers. To set up the self evaporating tray The self evaporating tray must be placed under the unit, at the place designed, by means of the clips initially installed. The installation twist of the self evaporating tray must be connected to the plug of the electric box, according the standard of unit, the twist of the self evaporating tray can be situed in the face or in the back of the unit. Astainless steel sheet deflector located in the self evaporating tray, allow to direct the water vapour. The sheet must be located in the middle of the self evaporating tray ( the same distance in each side). The deflector must be located to have the good direction of the inclination, like described in the following diagram. deflector UTILISATION To put into service Powering up the unit two hours before usage. Switch on the function mode desired : Chilled ventilated air function, Hot ventilated air function, Dry Bain Marie function. The corresponding thermostat turn on. The thermostat is adjusted in the factory after testing. When the desired temperature is obtained, the power unit automatically turns off. Positionner le commutateur sur la position 0 pour arrêter le fonctionnement du reverso. Dry Bain-marie function 150 mm deep gastronorm GN 1/1 trays should be used. With the parameters programs in factory, the food s temperature is maintened above +65 C which is the minimum temperature defined by Health Departments. To be able to hold this temperature, it is essential to bring food to a temperature ranging between +70 C and +80 C. Lightning Press the switch on/off to turn on or turn off the lighting Turn to the right the variator to turn on the halogen lamps. Adjusting the thermostat Refer to the manual for details. Automatic defrosting This function is programmed in the thermostat/ Adjusted in the factory: the defrosting engages every hour throughout one ten maximum minute. To modify the adjustment, refer the manual of the thermostat. Cleaning To be performed when the unit is shut down (the unit is turned off). Once a day, wash the top, the refrigerated well and the external sides of the unit. Use a sponge moistened with a soapy water or special cleaning products to clean the stainless steel. Rinse off with water. Dry preferably with lint-free cotton cloths. Do not use floor cleaning products or acids, even diluted, chlorinated or scouring products, which may cause corrosion to stainless steel. Do not use any abrasive products (steel wool, etc ). Do not clean the refrigerated unit by spraying with water, using a soap gun, or under high pressure jets. MAINTENANCE The installer should check all the electric connections during the initial start up of the unit (and then once a year). Clean the condenser every six months. Grease the condenser blower shaft once a year. 2

3 ELECTRIC DIAGRAM REFRIGERATING DIAGRAM CAPTION DIAGRAMS B Ballast Rb Self-evaporating tray heating element C Compressor Rd Defrost heating element Ca Capillary Sf Starter Cd Condensor Sn Level probe D Relief valve St Atmosphere temperature probe Dh Drier Tb Safety thermostat for self evaporating tray E Evaporator Tf Fluorescent tub I 4 positions switch Tr Thermostat XR40 Kb Self evaporating tray relay Ts Safety Thermostat Kd Defrost relay V Well ventilator Lh Halogen lamp Va Variator Q Fuse holder Vc Condensor fan R Heating element 3

4 MANUAL OF THERMOSTAT XW40L Please read this manual before using 1.AVERTISSEMENT Warning: disconnect all electrical connections before any kind of maintenance. The instrument must not be opened. In case of failure or faulty operation send the instrument back to the distributor or to with a detailed description of the fault. 2.DESCRIPTION Model XW40L is microprocessor based controllers suitable for applications on medium or low temperature refrigerating units. They are provided with 3 relay outputs to control compressor, defrost - which can be either electrical or hot gas - and the lights. They are also provided with 1 NTC or PTC probe inputs, for temperature control. The regulation is performed according to the temperature measured by the thermostat probe with a positive differential from the set point: if the temperature increases and reaches set point plus differential the compressor is started and then turned off when the temperature reaches the set point value again. 3.KEYBOARD To display and modify target set point; in programming mode it selects a parameter or confirm an operation. By holding it pressed for 3s when max or min temperature is displayed it will be erased. To see the max. stored temperature; in programming mode it browses the parameter codes or increases the displayed value. By holding it pressed for 3s the fast freezing cycle is started. To see the min stored temperature; in programming mode it browses the parameter codes or decreases the displayed value. By holding it pressed for 3s the defrost is started. Switch ON and OFF the light of the cold-room. Switch ON and OFF the instrument. KEY COMBINATIONS To lock and unlock the keyboard. To enter the programming mode. To exit the programming mode. 3.1 To lock and unlock the keyboard HOW TO LOCK THE KEYBOARD Keep the and the keys together for more than 3 s. The "POF" message will be displayed and the keyboard is locked. At this point it is only possible the viewing of the set point or the MAX or Min temperature stored and to switch ON and OFF the light, the auxilary output and the instrument. HOW TO UNLOCK THE KEYBOARD Keep the and the keys pressed together for more than 3 s. The "POn" message will be displayed and the keyboard is unlocked. 3.2 Meaning of the LED Each LED function is described in the following table : LED MODE FONCTION ON The compressor is running Flashing Programmation phase ( flashing with Anti-short cycle delay enabled ) ON The fan is running. Flashing Programmation phase ( flashing with ) ON The defrost is enabled. Flashing Drip time in progress ON The fast freezing cycle is enable Alarm signal ON In Pr2 indicates that the parameter is also present in Pr1 ON The light is on 3.3 How to see the min temperature Press and release the n key. The Lo message will be displayed followed by the minimum temperature recorded. By pressing the n key or waiting for 5s the normal display will be restored. 3.4 How to see the max temperature Press and release the o key. The Hi message will be displayed followed by the maximum temperature recorded. By pressing the o key or waiting for 5s the normal display will be restored. 3.5 How to reset the max and min temperature recorded To reset the stored temperature, when max or min temperature is displayed, press SET key until rst label starts blinking. N.B. : After the installation RESET the temperature stored. 3.6 How to see and modify the set point Push and immediately release the SET key: the display will show the Set point value. The SET LED start blinking. To change the Set value push the or arrows within 10s. To memorise the new set point value push the SET key again or wait 10s. 3.7 To start a manual defrost Push the DEF key for more than 2 seconds and a manual defrost will start. 3.8 To enter in parameters list Pr1 To enter the parameter list Pr1 (user accessible parameters) operate as follows: Enter the Programming mode by pressing the Set and DOWN key for few seconds ( and start blinking). The instrument will show the first parameter present in Pr1. 4

5 3.9 To enter in parameters list Pr2 To reach the parameters present in "Pr2" (parameters accessible to the technicians), please contact, which will deliver you the secret code making it possible to reach these parameters. 4. ALARM SIGNALS Message Cause Output "P1" "HA" "LA" "EE" Thermostat probe failure Maximum temperature alarm Minimum temperature alarm Data or memory failure Alarm output ON; Compressor output according to parameters COn and COF Alarm output ON; Other outputs unchanged Alarm output ON; Other outputs unchanged Alarm output ON; Other outputs unchanged The alarm message is displayed until the alarm condition is recovery. All the alarm messages are showed alternating with the room temperature except for the P1 which is flashing. To reset the EE alarm and restart the normal functioning press any key, the rst message is displayed for about 3s. 4.1 EE alarm The instruments are provided with an internal check for the data integrity. Alarm EE flashes when a failure in the memory data occurs. In such cases the alarm output is enabled. 4.2 Alarm recovery Probe alarms P1 (probe1 faulty), P2 ; they automatically stop 10s after the probe restarts normal operation. Check connections before replacing the probe. Temperature alarms HA and LA automatically stop as soon as the thermostat temperature returns to normal values or when the defrost starts. 5. PARAMETERS PROGRAMS IN FACTORY Parameter Name Default Set Set point 2 Hy Differential 1 AC Anti-short cycle delay 1 res Resolution (integer/decimal point) de tdf Defrost type re dte Defrost termination temperature 1 IdF Interval between defrost cycles 1 MdF (Maximum) length for defrost 4 ALU MAXIMUM temperature alarm 8 ALL Minimum temperature alarm 2 ot Thermostat probe calibration 6 P2P Evaporator probe presence n Adr Address series (unused) 1 P2r Access parameter list ( read only) 1 5

6 MANUAL OF THERMOSTAT XT110C Please read this manual before using 1.AVERTISSEMENT Warning: disconnect all electrical connections before any kind of maintenance. The instrument must not be opened. In case of failure or faulty operation send the instrument back to the distributor or to with a detailed description of the fault. 2.GENERAL DESCRIPTION The XT110C and XT111C are single-stage ON/OFF controllers for temperature, humidity and pressure applications with direct or inverse action, user-selectable. The analogue input type can be set by parameter between the following, according to the model: - PTC, NTC; - PTC, NTC, Pt100, Thermocouple J, K, S; 4 20mA, 0 1V, 0 10V. 3.FRONT PANEL COMMAND SET: To display and modify target set point; in programming mode it selects a parameter or confirm an operation. TO SWITCH THE INSTRUMENT ON/OFF: If the function is enabled (par. onf=yes), by pressing the SET key for more than 4s the controller is switched OFF. To switch the instrument on again press the SET key. o UP: in programming mode it browses the parameter codes or increases the displayed value. Hold it pressed for a faster change n DOWN: in programming mode it browses the parameter codes or decreases the displayed value. Hold it pressed for a faster change KEY COMBINATIONS: o + n To lock & unlock the keyboard. SET + n To enter in programming mode. SET + o To return to the room temperature display. 3.1 Use of LEDs Each LED function is described in the following table : LED MODE FUNCTION ON Output relay enabled LED1 Flashing - Programming Phase (flashing with LED2) LED2 Flashing - Programming Phase (flashing with LED1) E.S. ON Energy saving activated by digital input ON - ALARM signal - In Pr2 indicates the parameter is also present in Pr1 3.2 To see the set point Push and release the SET key to see the Set point value To come back to the normal display push again the SET key or wait 10s. 3.3 To change the set point Hold pushed the SET key for 3s to change the Set point value The value of the set point will be displayed and the LED1 & 2 start blinking To change the Set value push the o or n arrows within 10s. To memorise the new set point value push the SET key again or wait 10s. 3.4 To enter the parameters list PR1 Push for 3s the SET + n keys (LED1 & 2 start blinking). The controller will display the first parameter present in the Pr1 menu. 3.5 How to change a parameter - Enter the Programming mode - Select the required parameter. - Press the SET key to display its value. - Use UP or DOWN to change its value. - Press SET to store the new value and move to the following parameter. TO EXIT: Press SET + UP or wait 15s without pressing a key. NOTE: the set value is stored even when the procedure is exited by waiting the time-out to expire. 3.6 How to lock the keyboard Keep pressed together for more than 3s the the o and n keys, till the POF message will be displayed. 3.7 To unlock the keyboard Keep pressed together for more than 3s the the o and n keys, till the Pon message will be displayed. 4.ALARM SIGNALS Message Cause Outputs PFo Probe broken or absence Alarm output ON; Output according to parameter So1 PFc Probe short circuited Alarm output ON; Output according to parameter So1 HA Maximum alarm Alarm output ON; Other outputs unchanged. LA Minimum alarm Alarm output ON; Other outputs unchanged. EAL External alarm Output unchanged. bal Serious external alarm Output OFF. 5. PARAMETERS PROGRAMS IN FACTORY Parameter 40 C 80 C Set Hy LS US S1C In In Ac 0 0 OPb

7 SPARE PARTS Length of the unit Code Item Jack with gas Adlin X X X X Safety Thermostat X X X X Tangential Ventilator Ebmpapst réf ZWU X X X X Starter for fluorescent tub X X X X Thermostat Dixell XR40C X X X X Thermostat Dixell XT110C X X X X positions switch X X X X Resistance with blades length 415 mm power 750 W X X Resistance with blades length 300 mm power 500 W X Resistance with blades length 625 mm power 1250 W X Evaporator length 580 X Evaporator length 900 X Evaporator length 1230 X Evaporator length 1550 X Option crawl heating halogen Halogen lamp power 200W X X X X Aluminium reflector X X X X Protective glass + fixing X X X X Variator X X X X Lighting Orange indicator switch X X X X Fluorescent tub 436 mm 12 W X Fluorescent tub 893 mm 30 W X Fluorescent tub 966 mm 36 W X Fluorescent tub 1196 mm 36 W X Ballast 15 W X Ballast 30 W X Ballast 36 W X X SAV Francis LECOMTE Fax : sav@vauconsant.com 7

OMNITOP Refrigerated Display with Ventilated Cooling

OMNITOP Refrigerated Display with Ventilated Cooling OMNITOP Refrigerated Display with Ventilated Cooling Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4 Spare parts page 6 Rue Charles

More information

MINITOP Refrigerated Self-Service Display underneath

MINITOP Refrigerated Self-Service Display underneath MINITOP Refrigerated Self-Service Display underneath Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4 Spare parts page 6 Rue Charles

More information

Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4 Spare parts page 6

Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4 Spare parts page 6 INOUK Upright refrigerated display Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4 Spare parts page 6 Rue Charles Hermite Z.I. des

More information

Dixell Installing and Operating Instructions release 7.0

Dixell Installing and Operating Instructions release 7.0 XR160C - XR160D - XR170C - XR170D - XR162C - XR172C CONTENTS 1. GENERAL WARNING 2 1.1 Please read before using this manual 2 1.2 Safety Precautions 2 2. GENERAL DESCRIPTION 2 3. CONTROLLING LOADS 2 3.1

More information

Commercial Refrigerator Service Manual

Commercial Refrigerator Service Manual Commercial Refrigerator Service Manual SOLID DOOR TOP MOUNT REACH-IN PTM49R Please read this manual completely before attempting to install or operate this equipment. TABLE OF CONTENTS 1. FEATURE CHART

More information

Commercial Freezer Service Manual

Commercial Freezer Service Manual Commercial Freezer Service Manual SOLID DOOR TOP MOUNT REACH-IN PTM49F Please read this manual completely before attempting to install or operate this equipment. TABLE OF CONTENTS 1. FEATURE CHART 1-1.

More information

XR60C ,QVWDOOLQJDQG2SHUDWLQJ,QVWUXFWLRQV. Digital controller with defrost and fans management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS

XR60C ,QVWDOOLQJDQG2SHUDWLQJ,QVWUXFWLRQV. Digital controller with defrost and fans management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS Digital controller with defrost and fans management XR60C CONTENTS 1. GENERAL WARNING 1 2. GENERAL DESCRIPTION 1 3. CONTROLLING LOADS 1 4. FRONT PANEL COMMANDS 1 5. TEMPERATURE ALARM AND ITS DURATION RECORDING

More information

OPERATING INSTRUCTIONS ULTF 80 / 220 / 320 / 420

OPERATING INSTRUCTIONS ULTF 80 / 220 / 320 / 420 OPERATING INSTRUCTIONS ULTF 80 / 220 / 320 / 420 INDEX........................................................... PAGE Before using the appliance...............................................................

More information

dixel Installing and Operating Instructions PRELIMINAY

dixel Installing and Operating Instructions PRELIMINAY . GENERAL WARNING XW6K - AFV PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument for easy and quick reference. The instrument shall not be used

More information

XWA11V. Walk-In Temp / Door /Alarm / Light Module

XWA11V. Walk-In Temp / Door /Alarm / Light Module XWA11V Walk-In Temp / Door /Alarm / Light Module 1. GENERAL DESCRIPTION Model XWA11V, 100x64 mm format, is a microprocessor-based controller, suitable for temperature monitoring and alarming in a walk-in

More information

Top Mount Full Length Swinging Doors

Top Mount Full Length Swinging Doors Top Mount Full Length Swinging Doors *Shown in FT103SD3 model Model FT77SD FT103SD3 FT138SD Width 77 103 138½ Depth 32 32 32 Height 86 ½ 86 ½ 86 ½ Volume/cu. Ft. 77 103 140 Doors 3 3 4 Door Size 23 x 66

More information

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring 1. GENERAL DESCRIPTION Model XWA11V-KIT, 100x64 mm format, is a microprocessor based light and alarm management controller,

More information

Operating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module

Operating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module XWA11V Walk-In Temp / Door /Alarm / Light Module 1. GENERAL DESCRIPTION Model XWA11V, 100x64 mm format, is a microprocessor-based controller, suitable for temperature monitoring and alarming in a walk-in

More information

Digital Controller XR70CX. Operating Manual. 5/10 Rev. B

Digital Controller XR70CX. Operating Manual. 5/10 Rev. B Digital Controller XR70CX Operating Manual 5/10 Rev. B 139734 Contents General Warnings 3 General Description 3 Regulation 3 Defrost 3 Fans 4 Front Panel Commands 4 Parameters 6 Installation and Mounting

More information

dixel Installing and Operating Instructions

dixel Installing and Operating Instructions XW20K AND T620 V620 CX620 1. GENERAL WARNING PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument for easy and quick reference. The instrument

More information

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring 1. GENERAL DESCRIPTION Model XWA11V-KIT, 100x64 mm format, is a microprocessor based light and alarm management controller,

More information

User Instructions Lab* Frost. Ultra Low Temperature Freezers Model LAB

User Instructions Lab* Frost. Ultra Low Temperature Freezers Model LAB User Instructions Lab* Frost Ultra Low Temperature Freezers Model LAB SAFETY INFORMATIONS The LAB freezers contains environmentally friendly but flammable refrigerants. It means danger of explosion if

More information

Refrigerated Milk Drawer

Refrigerated Milk Drawer Refrigerated Milk Drawer Copyright Septamber 2016 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any

More information

XH260L XH260V. Dixell Operating instructions TEMPERATURE AND HUMIDITY CONTROLLER 1. GENERAL WARNING

XH260L XH260V. Dixell Operating instructions TEMPERATURE AND HUMIDITY CONTROLLER 1. GENERAL WARNING XH260L XH260V TEMPERATURE AND HUMIDITY CTROLLER 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument for easy and quick

More information

XR60CX. Installation and Operating Instructions. Digital controller with defrost and fans management. + + To return to the room temperature display.

XR60CX. Installation and Operating Instructions. Digital controller with defrost and fans management. + + To return to the room temperature display. Digital controller with defrost and fans management XR60CX CTENTS 1. GENERAL WARNING 1 2. GENERAL DESCRIPTI 1 3. CTROLLING LOADS 1 4. FRT PANEL COMMANDS 1 5. MAX & MIN TEMPERATURE MEMORIZATI 1 6. MAIN

More information

Inline GN Series Refrigerated Well

Inline GN Series Refrigerated Well Inline GN Series Refrigerated Well Copyright June 2017 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in

More information

UNIVERSAL R V3.0. NEW FEATURES on the V3.0

UNIVERSAL R V3.0. NEW FEATURES on the V3.0 UNIVERSAL R V3.0 NEW FEATURES on the V3.0 HEATING : As well as cooling, the Universal-R can now be used to control heating applications up to +105c, using the NTC probes supplied in box. For temperatures

More information

XW40K AND T620T - T620 V620 CX620

XW40K AND T620T - T620 V620 CX620 XW40K AND T620T - T620 V620 CX620 1 GENERAL WARNING... 1 2 GENERAL DESCRIPTI... 1 3 CTROLLING LOADS... 1 4 SPECIAL FUNCTIS... 1 5 KEYBOARDS... 1 6 AUTOMATIC KEYBOARD LOCK (LY FOR T620T)... 2 7 CTROLLER

More information

dixel Installing and Operating Instructions 1592027050 Digital controller for medium-low temperature refrigeration applications XW60L 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual

More information

TOQUE BLANCHE GRANDE CARTE

TOQUE BLANCHE GRANDE CARTE REFRIGERATED BASES TOQUE BLANCHE GRANDE CARTE MAINTENANCE MANUAL MANUFACTURERS SPECIFICATION BONNET GRANDE CUISINE Rue des Frères Lumière - Z.I. Mitry Compans 77292 MITRY MORY cedex Tél. 01 60 93 70 00

More information

Sf2+HF2 Sf2 Sf1 + Hf1 Sf1. 1 ON Fan1 enabled (only for XC30CX) 2 ON Fans enabled (only for XC30CX) kpa. Time

Sf2+HF2 Sf2 Sf1 + Hf1 Sf1. 1 ON Fan1 enabled (only for XC30CX) 2 ON Fans enabled (only for XC30CX) kpa. Time Digital controller for CDU management XC10CX and XC30CX 1. GENERAL WARNING... 1 2. GENERAL DESCRIPTION... 1 3. CONTROLLING LOADS... 1 4. FRONT PANEL COMMANDS... 1 5. OTHER FUNCTIONS... 1 6. MAIN INTERFACE...

More information

Refrigerated air dryers

Refrigerated air dryers Refrigerated air dryers OPERATING AND MAINTENANCE MANUAL Original instructions 38178800319 OPERATING AND MAINTENANCE MANUAL - Contents 1 CONTENTS CONTENTS... 1 Chapter 1 IDRY ELECTRONIC CONTROLLER...

More information

OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES. Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ATF2 ATR2

OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES. Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ATF2 ATR2 OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ABF1 ABF2 ABF3 ABR1 ABR2 ABR3 ABF1 ABR1 ATF2 ATR2 ABF3 ABR3 Please read the manual carefully and follow all instructions.

More information

XH50P - XH55P Temperature/relative humidity probe with RS485 serial line

XH50P - XH55P Temperature/relative humidity probe with RS485 serial line XH50P - XH55P Temperature/relative humidity probe with RS485 serial line 1. GENERAL WARNINGS 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument

More information

XC10CX and XC30CX. Digital controller for CDU management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS 2. GENERAL DESCRIPTION

XC10CX and XC30CX. Digital controller for CDU management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS 2. GENERAL DESCRIPTION Digital controller for CDU management XC10CX and XC30CX 1. GENERAL WARNING... 1 2. GENERAL DESCRIPTION... 1 3. CONTROLLING LOADS... 1 4. FRONT PANEL COMMANDS... 1 5. OTHER FUNCTIONS... 1 6. MAIN INTERFACE...

More information

User Instructions Ultra Low Temperature Freezers Model LAB/ULT

User Instructions Ultra Low Temperature Freezers Model LAB/ULT Elcold Frysere Hobro ApS Løgstørvej 81 Hørby 95 Hobro Denmark Phone +45 9657 2222 Fax +45 9852 4685 Email elcold@elcold.com www.elcold.com i.c. graphics cph User Instructions Lab* Frost Ultra Low Temperature

More information

Electronic Controller For Refrigeration XLR130 XLR170

Electronic Controller For Refrigeration XLR130 XLR170 Electronic Controller For Refrigeration XLR130 XLR170 Instructions Manual COOL OOLMATE XLR130C XLR170C INDEX 1. GENERAL WARNING 3 2. GENERAL DESCRIPTION 3 3. CONTROLLING LOADS 3 4. KEYBOARD 5 5. REAL TIME

More information

1 NORMS AND REGULATIONS Guarantee norms: Environmental notes: Identification:... 15

1 NORMS AND REGULATIONS Guarantee norms: Environmental notes: Identification:... 15 Index 1 NORMS AND REGULATIONS... 15 1.1 Guarantee norms:... 15 1.2 Environmental notes:... 15 1.3 Identification:... 15 2 INSTALLATION... 16 2.1 Lifting and Movement:... 16 2.2 Positioning:... 16 2.3 Environmental

More information

Refrigerated Cabinets Square Format

Refrigerated Cabinets Square Format Refrigerated Cabinets Square Format Copyright December 2017, Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

Rev 0 09-FEB XR75CX Digital Controller for Medium-Low Temperature Refrigeration Applications Installation and Operation Manual

Rev 0 09-FEB XR75CX Digital Controller for Medium-Low Temperature Refrigeration Applications Installation and Operation Manual 026-1210 Rev 0 09-FEB-2011 XR75CX Digital Controller for Medium-Low Temperature Refrigeration Applications Installation and Operation Manual Retail Solutions 3240 Town Point Drive NW Suite 100 Kennesaw,

More information

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A Blast Chiller / Freezer Instruction Manual Model DN492-A DN494-A Safety Tips Position on a flat, stable surface. A service agent/qualified technician should carry out installation and any repairs if required.

More information

Time KEY COMBINATIONS: + To lock & unlock the keyboard. + To enter in programming mode. + To return to the room temperature display. 4.

Time KEY COMBINATIONS: + To lock & unlock the keyboard. + To enter in programming mode. + To return to the room temperature display. 4. Digital controller for medium-low temperature refrigeration applications XW40L 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the

More information

XB570L XB570L. dixel Operating and Instructions Manual BLAST CHILLER - QUICK CHILL AND HOLD FUNCTION

XB570L XB570L. dixel Operating and Instructions Manual BLAST CHILLER - QUICK CHILL AND HOLD FUNCTION XB570L BLAST CHILLER - QUICK CHILL AND HOLD FUNCTION Contents 1. General warning 1 2. General Features 1 3. Mounting & Installation 1 4. Electrical Connections 1 5. Connections 1 6. Frontal panel 1 7.

More information

Open Front Food & Drinks Cabinet AS/NZS

Open Front Food & Drinks Cabinet AS/NZS Open Front Food & Drinks Cabinet AS/NZS Copyright November 2017 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

Sf2+HF2 Sf2 Sf1 + Hf1 Sf1. DLT Prb. Ground

Sf2+HF2 Sf2 Sf1 + Hf1 Sf1. DLT Prb. Ground Digital controller for CDU management XC30CX 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument for easy and quick reference.

More information

Upright Chiller & Freezer Service, Installation and Care Manual

Upright Chiller & Freezer Service, Installation and Care Manual Upright Chiller & Freezer Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment. Notify carrier of damage! Inspect all components

More information

Refrigerated Cabinets

Refrigerated Cabinets Refrigerated Cabinets Copyright June 2017 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or

More information

Read and save these instructions

Read and save these instructions www.winemate.com Wine Cooling System WM-1500HZD, WM-2500HZD WM-3500HZD, WM-4500HZD WM-6500HZD, WM-8500HZD Installation, Use & Care Manual www.vinotemp.com Read and save these instructions Important Safety

More information

XW70L. Digital controller for medium-low temperature refrigeration applications AUX 1. GENERAL WARNING 2. GENERAL DESCRIPTION 3.

XW70L. Digital controller for medium-low temperature refrigeration applications AUX 1. GENERAL WARNING 2. GENERAL DESCRIPTION 3. Digital controller for medium-low temperature refrigeration applications XW70L 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the

More information

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL WATER HEATER ELECTRONIC CONTROLLER USER MANUAL UPPER LED READOUT LED ICONS LOWER LED READOUT PVI INDUSTRIES, LLC - Fort Worth, Texas 76111 - Web www.pvi.com - Phone 1-800-433-5654 Page 1 / 7 PV500-40 03/17

More information

AIR COOLED CHILLERS MODELS: MPCA0005 MPCA0150 INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

AIR COOLED CHILLERS MODELS: MPCA0005 MPCA0150 INSTALLATION, OPERATION, AND MAINTENANCE MANUAL MOTIVAIR COOLING SOLUTIONS AIR COOLED CHILLERS MODELS: MPCA0005 MPCA0150 INSTALLATION, OPERATION, AND MAINTENANCE MANUAL This chiller has been factory run tested to the specified water pressure *****DO

More information

Refrigerated Cabinets Curved Format

Refrigerated Cabinets Curved Format Refrigerated Cabinets Curved Format Copyright August 2018, Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

Food & Beverage Cabinet

Food & Beverage Cabinet Food & Beverage Cabinet Copyright June 2017 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or

More information

Read and save these instructions

Read and save these instructions www.winemate.com Wine Cooling System WM-1500HZD, WM-2500HZD WM-3500HZD, WM-4500HZD WM-6500HZD, WM-8500HZD Installation, Use & Care Manual www.vinotemp.com Read and save these instructions Important Safety

More information

XR77CX. dixel Installing and Operating Instructions Digital controller for medium-low temperature refrigeration applications

XR77CX. dixel Installing and Operating Instructions Digital controller for medium-low temperature refrigeration applications Digital controller for medium-low temperature refrigeration applications XR77CX 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the

More information

Refrigerated Cabinets Curved Format

Refrigerated Cabinets Curved Format Refrigerated Cabinets Curved Format Copyright August 2018 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

REFRIGERATED ROOM & TEMPERATURE/HUMIDITY CONTROLLERS

REFRIGERATED ROOM & TEMPERATURE/HUMIDITY CONTROLLERS SECTION INDEX FUNCTIONS MODELS XLR100 COOL MATE - NT, MT AND LT APPLICATIONS - SERIAL OUTPUT Advanced multifunction controllers for NT refrigerated rooms XLR130 Advanced multifunction controllers for MT

More information

SERVICE & SETUP MANUAL WATER HEATER ELECTRONIC CONTROLLER

SERVICE & SETUP MANUAL WATER HEATER ELECTRONIC CONTROLLER SERVICE & SETUP MANUAL WATER HEATER ELECTRONIC CONTROLLER PVI INDUSTRIES, LLC - Fort Worth, Texas 76111 - Web www.pvi.com - Phone 1-800-433-5654 Page 1/ 24 PV500-41 03/17 INDEX 1. TECHNICAL DATA 3 2. WIRING

More information

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A Blast Chiller / Freezer Instruction Manual Model DN492-A DN494-A 1 Safety Tips Position on a flat, stable surface. A service agent/qualified technician should carry out installation and any repairs if

More information

Ceiling Split Cooling System Installation, Operation & Care Manual WM-2500SSD WM-4500SSD WM-6500SSD WM-8500SSD

Ceiling Split Cooling System Installation, Operation & Care Manual WM-2500SSD WM-4500SSD WM-6500SSD WM-8500SSD www.winemate.com Ceiling Split Cooling System Installation, Operation & Care Manual WM-2500SSD WM-4500SSD WM-6500SSD WM-8500SSD www.vinotemp.com Read and save these instructions Important Safety Information

More information

Rev 1 24-MAY XR75CX Digital Controller for Medium-Low Temperature Refrigeration Applications Installation and Operation Manual

Rev 1 24-MAY XR75CX Digital Controller for Medium-Low Temperature Refrigeration Applications Installation and Operation Manual 026-1210 Rev 1 24-MAY-2012 XR75CX Digital Controller for Medium-Low Temperature Refrigeration Applications Installation and Operation Manual Retail Solutions 3240 Town Point Drive NW Suite 100 Kennesaw,

More information

XC1008D -XC1011D- XC1015D and VGC810

XC1008D -XC1011D- XC1015D and VGC810 Electronic Controller for Compressor Racks XC1008D -XC1011D- XC1015D and VGC810 Instructions Manual INDEX 1. GENERAL WARNING 4 1.1 PLEASE READ BEFORE USING THIS MANUAL 4 1.2 SAFETY PRECAUTIONS 4 2. WIRING

More information

Label Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature

Label Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature EVCO S.p.A. EV3B24 Data sheet ver. 1.0 Code 1043B24E104 Page 1 of 6 PT 12/15 EV3B24 Basic controller for low temperature bottle coolers, cabinets, refrigerated cabinets, tables and pizza counters, with

More information

Beverage Air IMPORTANT

Beverage Air IMPORTANT Beverage Air IMPORTANT INFORMATION FOR CT96 MODEL This cooler has passed the QUALITY CONTROL INSPECTION And meets the high standards for Beverage-Air Refrigeration products IMPORTANT PLEASE RETAIN FOR

More information

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner GUARDIAN SERIES KNA4C9DP47L-1

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner GUARDIAN SERIES KNA4C9DP47L-1 GUARDIAN SERIES KNA4C9DP47L-1 Keep This Manual With Air Conditioner Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents AIR CONDITIONER

More information

WH7016E Thermostat Product Manual

WH7016E Thermostat Product Manual WH7016E Thermostat Product Manual Shenzhen Willhi Electronics Co., Ltd. Tel :0755-29539385 Fax :86-0755 -2953 9395 Technical support: Engineer Tian 1 Installation opening size: 2 Wiring diagram: 1 2 3L

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL Refrigerated Cases with Air-Over Displays Refrigerated High Profile Grab-N-Go FOR PARTS & SERVICE Contact: Piper Products, Inc. Phone: (800) 544-3057 Ask for Service Department

More information

Read and save these instructions

Read and save these instructions www.winemate.com Customizable Wine Cooling System WM-4510HZD WM-6510HZD WM-8510HZD Installation, Use & Care Manual www.vinotemp.com Read and save these instructions Important Safety Information NOTES:

More information

Read and save these instructions

Read and save these instructions Split Ceiling-Mounted Cooling System Operation Care Installation Manual WM-2500SSD WM-2500SSD-LA WM-4500SSD WM-4500SSD-LA WM-6500SSD WM-6500SSD-LA WM-8500SSD WM-8500SSD-LA WM-12000SSD WM-12000SSD-LA www.vinotemp.com

More information

XH340L-V TEMPERATURE AND HUMIDITY CONTROLLER FOR SEASONING-MATURING CABINETS 1. GENERAL WARNING

XH340L-V TEMPERATURE AND HUMIDITY CONTROLLER FOR SEASONING-MATURING CABINETS 1. GENERAL WARNING XH340L-V TEMPERATURE AND HUMIDITY CTROLLER FOR SEASING-MATURING CABINETS 1. GENERAL WARNING 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument

More information

Chef Base Refrigerators

Chef Base Refrigerators Chef Base Refrigerators Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment. Notify carrier of damage! Inspect all components

More information

IKEA USA Refrigerated Cabinets

IKEA USA Refrigerated Cabinets IKEA USA Refrigerated Cabinets Copyright March 2017 Future Products Group Limited. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any

More information

REF Series Undercounter Refrigerator

REF Series Undercounter Refrigerator REF Series Undercounter Refrigerator Order parts online www.follettice.com Installation, Operation and Service Manual Serial numbers B59000 to C4584 Following installation, please forward this manual to

More information

Pastry Cabinet KT 24. English INDEX

Pastry Cabinet KT 24. English INDEX INDEX 1. Standards and Regulations...5 1.1 Warranty...5 1.2 Identification...5 1.3 Technical Assistance...6 2. Data and Technical Characteristics...7 2.1 Main Characteristics...7 2.2 Product Categories...8

More information

Instruction Manual for HX-DX and HX-DXHP Heat Exchangers 3 / 2017

Instruction Manual for HX-DX and HX-DXHP Heat Exchangers 3 / 2017 Instruction Manual for HX-DX and HX-DXHP Heat Exchangers 3 / 2017 Model No. HX-36DX Model No. HX-120DX Check packing slip and product to see if they match. If not, contact Aqua Logic immediately!! Important:

More information

Solid Door Top Mount Reach-In Freezer

Solid Door Top Mount Reach-In Freezer Solid Door Top Mount Reach-In Freezer Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment. Notify carrier of damage! Inspect

More information

Glass Door Merchandiser Refrigerator and Freezer

Glass Door Merchandiser Refrigerator and Freezer Glass Door Merchandiser Refrigerator and Freezer (Swing and Sliding Door ) Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment.

More information

Split Wall-Recessed Cooling System Operation Care Installation Manual

Split Wall-Recessed Cooling System Operation Care Installation Manual Split Wall-Recessed Cooling System Operation Care Installation Manual WM-2520SSW 2520SSW-LA WM-4520SSW 4520SSW-LA www.vinotemp.com Read and save these instructions Vinotemp International Corp 17631 S Susana

More information

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort User manual CLIMATIC 2/4 - Controller Providing indoor climate comfort MUL35E-56 9-26 INDEX CONTENTS PAGE INDEX 1 GENERAL DESCRIPTION 2 THE KEYPAD, Climatic 2 3 THE KEYPAD, Climatic 4 4 THE KEYPAD REMOTE

More information

SERVICE MANUAL MULTI DECK 60 HOT MERCHANDISER MULTI DECK 100 HOT MERCHANDISER MULTI DECK 120 HOT MERCHANDISER CLASSIC DECK HOT MERCHANDISER

SERVICE MANUAL MULTI DECK 60 HOT MERCHANDISER MULTI DECK 100 HOT MERCHANDISER MULTI DECK 120 HOT MERCHANDISER CLASSIC DECK HOT MERCHANDISER SERVICE MANUAL MULTI DECK 60 HOT MERCHANDISER MULTI DECK 100 HOT MERCHANDISER MULTI DECK 120 HOT MERCHANDISER CLASSIC DECK HOT MERCHANDISER Classic Deck Hot Multi Deck 60 Multi Deck 100 Multi Deck 120

More information

CIAO series ICE CREAM DISPLAY CABINET. Maintenance And Use Manual

CIAO series ICE CREAM DISPLAY CABINET. Maintenance And Use Manual ICE CREAM DISPLAY CABINET CIAO series Maintenance And Use Manual Mail: PO Box 18542, Greensboro, NC 27419 Street: 5C Wendy Ct, Greensboro, NC 27409 Phone: 336-856-2919 Fax: 336-217-8838 Email: sales@advancedgourmet.com

More information

Read and save these instructions

Read and save these instructions Split Through-Ceiling Cooling System Operation Care Installation Manual WM-2500SSO WM-2500SSO-LA WM-4500SSO WM-4500SSO-LA www.vinotemp.com Read and save these instructions Vinotemp International Corp 17631

More information

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB H SSGB Technical Data Sheet P/N 3018921_E EPH Certified to NSF-7 January 2018 F A C D E A G B We reserve the right to change or revise specifications and product design in connection with any feature of

More information

Read and save these instructions

Read and save these instructions Split Water-Cooled Through-Ceiling Cooling System Operation Care Installation Manual WM-2500SSOWC WM-4500SSOWC www.vinotemp.com Read and save these instructions Vinotemp International Corp 17631 S Susana

More information

Pastry Cabinet Mod.Koreia

Pastry Cabinet Mod.Koreia INDEX 1. Standards and Regulations...5 1.1 Warranty...5 1.2 Identification...5 1.3 Technical Assistance...6 2. Data and Techcnical Characteristics...7 2.1 Main Characteristics...7 2.2 Categorie di Prodotto...8

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL Refrigerated Merchandisers with Air-Over Displays Refrigerated Low-Profile Mobile Merchandiser Refrigerated High-Profile Mobile Merchandiser Refrigerated Grab-N-Go Merchandiser

More information

Read and save these instructions

Read and save these instructions Split Water-Cooled Central-Ducted Cooling System Operation Care Installation Manual WM-2500SSHWC WM-4500SSHWC WM-6500SSHWC WM-8500SSHWC WM-12000SSHWC www.vinotemp.com Read and save these instructions Vinotemp

More information

User Guide ems25plus. Page 1. Normal operation. Product interface

User Guide ems25plus. Page 1. Normal operation. Product interface Page 1 Product interface rmal operation During normal operation, EMS controllers display the information below. Assuming the product temperature is correct when the outlet is open, this means that the

More information

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB Summary 1 CONNECTIONS... 3 1.1 TEMPERATURE PROBES...3 1.2 LOW VOLTAGE DIGITAL INPUTS...3 1.3 LIVE DIGITAL INPUTS...4 1.4 RELAY OUTPUTS...5 2 POWER SUPPLY... 6 3 SERIAL CONNECTIONS... 6 4 SOFTWARE... 7

More information

ER52 - Evaporator Controller

ER52 - Evaporator Controller ER52 - Evaporator Controller Electronic Refrigeration Line Product Bulletin Devices are standalone digital controller for static or ventilated refrigeration units working at positive temperatures. They

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL Refrigerated Island Merchandiser FOR PARTS & SERVICE Contact: Piper Products, Inc. Phone: (800) 544-3057 Ask for Service Department IMPORTANT! This manual contains important

More information

Side-by-side combined refrigerator-freezer

Side-by-side combined refrigerator-freezer REPAIR INSTTRUCTTI I IONS Side-by-side combined refrigerator-freezer 1 SAFETY... 2 4.1 Electronic controller... 8 1.1 Safety instructions... 2 1.2 Repair instructions... 2 2 INSTALLATION... 3 3 OPERATION...

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL Salad Bars Olive Bars Food Prep Cases Refrigerated Cases with Air-Over Displays Refrigerated Cases with Coppered Cold Well Displays Cases with Under-Counter Refrigerators

More information

Thermometers and temperature controllers

Thermometers and temperature controllers D144H002 Ed.07 GB Thermometers and temperature controllers User Manual Contents AKO Electromecánica thanks and congratulates you for purchasing our product, in whose development and manufacture the most

More information

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment. Notify

More information

User Manual Ichill 200 L/D (Firmware version 1.7)

User Manual Ichill 200 L/D (Firmware version 1.7) User Manual Ichill 2 L/D (Firmware version 1.7) Pag. 1 of 142 INDEX 1. GENERAL FEATURES...8 1.1 Main Function... 8 2. ICHILL 2L/D TABLE OF THE FEATURES...1 3. USER INTERFACE...11 4. REMOTE KEYBOARD...15

More information

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173) Evco S.p.A. Code 104K204E05 page 1/5 EVK204 Digital controller for ventilated refrigerating units, with HACCP and Energy Saving functions version 1.05 GB ENGLISH 1 PREPARATIONS 1.1 Important Please read

More information

CAREL IR33+ CONTROLLER

CAREL IR33+ CONTROLLER CAREL IR33+ CONTROLLER Programming Instructions The Carel IR33+ controller has a two-level menu system for programming the operation of the case; Level 1 and Level 2 program settings. Unlike IR33, the

More information

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS OPERATING INSTRUCTIONS

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS OPERATING INSTRUCTIONS COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS OPERATING INSTRUCTIONS CE COMMERCIAL REFRIGERATORS Model - S.N.: Volt: 220 Hz: 50 Amps: Watt: Watt (heating element): Fuse Amps: Refrigerant: R gr: Working

More information

KitchenAid Food Stream Solutions Classic and Integrated Series

KitchenAid Food Stream Solutions Classic and Integrated Series KitchenAid Food Stream Solutions Classic and Integrated Series KitchenAid Chapter list Installation Range overview Installation General Information Function Compressor Power Control Board Defrosting Heating

More information

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB Summary 1 CONNECTIONS... 8 1.1 TEMPERATURE PROBES...8 1.2 PRESSURE PROBES...9 1.3 LOW VOLTAGE DIGITAL INPUTS...10 1.4 LIVE DIGITAL INPUTS...11 1.5 RELAY OUTPUTS...12 2 VOLTAGE/FREQUENCY INPUT...13 3 POWER

More information

FX BLAST CHILLER ISO ISO 9001

FX BLAST CHILLER ISO ISO 9001 FX BLAST CHILLER ISO 14001 ISO 9001 Contents Environmental Management Policy 1 Disposal Requirements 1 Cabinet description 2 Controller Description Controller Operation 2 to 3 Alarms & Warnings 4 Parameter

More information

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS INSTALLATION and OPERATION INSTRUCTIONS 4400 Series Power Paks MODEL NOS. 4400 Series 4404 4420 4410 4404W 4414 4410W 4414-230 4414W c IMPORTANT INFORMATION To register your product, visit our web site

More information

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA 0.8180.472.0 07/2005 Page 1. SPECIFICATIONS 3 1-1 Unit Specifications 3 1-2 Major Component Specifications 4 2. DIMENSIONAL DATA 6 2-1 Unit Dimensions 6 3. ELECTRICAL

More information

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner INTREPID SERIES K2A6C30EP56TR-4

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner INTREPID SERIES K2A6C30EP56TR-4 INTREPID SERIES K2A6C30EP56TR-4 Keep This Manual With Air Conditioner Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents AIR CONDITIONER

More information