LOCAL EXTRACTION Pure advantages. The ideal extractor for light industry and laboratory environments.

Size: px
Start display at page:

Download "LOCAL EXTRACTION Pure advantages. The ideal extractor for light industry and laboratory environments."

Transcription

1 The ideal extractor for light industry and laboratory environments. With its optimal design, the mm FUMEX ME has a very low pressure drop, which provides many valuable benefits. - Low pressure drop saves energy. - Air flow noise is reduced. - Lower pressure drop is achieved without selecting a larger diameter extractor. - Lower pressure drop allows the ME to be combined with additional extraction systems. To further facilitate maneuvering of the extractor, the models 1650 and 1900 are equipped with a pulling gas spring as standard and the models 2100 and 2650 with two pulling gas springs. An easy-to-grip handle facilitates the maneuverability of the extractor. Unique design and stable mounting brackets make the Fumex ME your best choise. Support for designing an effective system can be found on page 5, and at where you will find our design tool and CAD drawings. The Fumex range also includes fans, accessories, automatic control and filters suitable for local extraction. LOCAL EXTRACTION Pure advantages

2 Always choose a low pressure drop Lowest possible pressure drop is a quality aspect that always should be considered. With its uniquely designed joint construction, Fumex ME combines maximum flexibility with low pressure drop. The air passes through the joints without creating unnecessary turbulence, thus producing an energy-saving low pressure drop and a quieter working environment. Recommended air flow The recommended air flow for a Ø100 arm is m³/h, See table and diagram. Activity Air flow Laboratories m 3 /h l/s Light industry 300 m 3 /h 80 l/s Static pressure drop (Pa) Air flow (m 3 /h) Static pressure drop is measured in accordance with ISO standard Optimal capture For optimum benefit from the local extractor, it is important to use the flexibility of the extractor to get as close to the contaminant as possible. A good rule of thumb would be a distance of 2 3 times the diameter of the extractor tube. At the recommended air flow, the extractor will provide high efficiency even if disturbances are generated in the surroundings mm Unique benefits The Fumex ME s joints have a patented friction design that, combined with the large joint diameter and single grip handle, provide a secure, position-stable arm with smooth adjustments. All without the need to apply excessive force or use tools on the adjusting knob. Joints with reinforced ends and ball bearings moderate the friction and allow the arm to be moved up and down while maintaining stability and function. Handle for easy adjustment A steady and easily accessible handle, that provides easy adjustment, is fitted as a standard on all models of Fumex ME Ø100 mm.

3 One arm. All options. Fumex ME has a complete range of accessories to suit every situation, enabling you to create the optimal extractor for the evacuation of hazardous airborne gases and particulates. PP version Used primarily for evacuating very corrosive contaminants in high concentrations, e.g. in certain laboratories and in the pharmaceutical and chemical industries. Standard version Suitable for evacuating most types of airborne contaminants, e.g. in laboratories, schools, hospitals, the pharmaceutical industry, nail salons and light industrial applications. ATEX version Suitable for evacuating airborne contaminants where there is a requirement for an ATEXclassified environment, e.g. in laboratories, the chemical and petrochemical industries, gas distribution, and the paint and pharmaceutical industries.

4 MET for ceiling and wall mounting, 3 joints Standard Size (mm) Gas spring Weight MET ,9 MET ,4 MET ,9 MET ,4 MET ,9 MET B MET ,4 A PP Size(mm) Gas spring Weight MET PP ,9 MET PP ,4 MET PP ,9 MET PP ,4 MET PP ,9 MET PP ,4 MET for ceiling or wall mounting, excluding bracket MTI or MVK-125. ATEX Size (mm) Gas spring Weight MET EX ,9 MET EX ,4 MET EX ,9 MET EX ,4 MET EX ,9 MET EX ,4 Pressure drop dB(A) Static pressure drop (Pa) Air flow (m 3 /h) Static pressure drop is measured in accordance with ISO standard Noise level is measured in accordance with ISO standard Indicated sound level refers to sound pressure level.

5 MEB for table mounting, 3 joints Standard Size (mm) Gas spring Weight MEB ,9 MEB B MEB ,4 A MEB ,9 MEB ,4 PP Size (mm) Gas spring Weight MEB PP ,9 MEB PP ,4 MEB PP ,9 260 MEB PP ,4 ATEX Size (mm) Gas spring Weight MEB EX ,9 MEB EX , Ø 6 (4X) 119 MEB EX ,9 MEB EX ,4 Reach at recommended installation height The following installation heights and sideways displacement relative to the work area are recommended for optimal extraction: Recommended installation height Designation H (mm) MET MET MET MET MET MET MET 2650 MET 2100 MET 1900 MET 1650 MET 1350 MET 1150 MET 2650 MET 2100 MET 1900 MET 1650 MET 1350 MET S H Recommended side displacement radius, relative to work area 900 Designation S (mm) MET MET MET MET MET MET MET2650 MET2100 MET1900 MET1650 MET1350 MET1150 Working radius Maximum radius

6 Hoods Ø 250 METAL HOOD The metal hood is used when working in corrosive environments and for capturing hot gasses and dust splatter. Metal hoods can be fitted with work lighting. MEM PP, EX 510 Standard/PP: EX Powder-coated aluminium Powder-coated aluminium Ø 350 DOME HOOD The clear dome hood is suitable for lighter gasses with a wider dispersal of contaminants without blocking the user s vision. MEK PP,EX 610 Standard: PP EX PMMA Polypropylene, transparent PEEL black Ø 500 DOME HOOD The clear dome hood is suitable for lighter gasses with a wider dispersal of contaminants without blocking the user s vision. MEK PP,EX 735 Standard: PP EX PMMA Polypropylene, opaque PEEL black SQUARE HOOD The square hood is suitable for placing above gases with a high lift, or adjacent to the work surface for contaminants with no lift or low lift all this without interfering with the work. MESH Standard: PETG ,5 200 FLAT SCREEN HOOD The flat screen hood is designed to maximise the working area without obscuring the object from the user. The flat screen hood gives the best suction effect for table and bench tasks. Temp. range: -15 C to +80 C MEPH PP,ES, EX 625 Standard: PP EX PETG Polypropylene PEEL black PROTECTIVE GRILL Protective grill to be monted in joints. Prevents objects being sucked into the system. MESG-100 EX 12 Standard, EX: EN

7 Brackets All Fumex laboratory extractors have as standard a full swivel that allows 360 of rotation without the need to add special sleeve couplings. Both ceiling and wall brackets have a special squareshaped profile in anodised aluminium to provide a stylish and stable installation. This aluminum profile also allows both the wall and ceiling brackets to be custom tailored at the job site. MTI MTI CT The MTI ceiling bracket The ceiling bracket functions as a simple and stable duct for outgoing air, avoiding the need for expensive ducting and additional holes through false ceilings. On request, the MTI can be supplied in lengths exceeding 2 m. Dimensions Weight (mm) Standard L (kg) MTI ,90 MTI ,80 MTI ,75 MTI ,65 MTI ,60 MTI ,50 MTI ,40 Static pressure drop (Pa) Air flow (L/s) MTI Air flow (m 3 /h) Ø10(x4) L Ø The MTF ceiling bracket Ceiling bracket, for fitting through beams. The attachment plate is adjustable for the entire length of the aluminium profile. If required, the aluminium profile can be cut during fitting. Ø10 (x4) Ø125 Dimensions Weight (mm) Standard L (kg) MTF ,50 As well as the standard design, the MTI/MTF is available in an ATEX (EX) version. 5 The ceiling brackets can be supplied with an epoxy-coated exterior in all lengths up to 3 m (L). For aggressive environments, we recommend epoxy coating on the interior and exterior up to 1.25 m (IL) The MTI CT escutcheon plate Escutcheon plate, used with the MTI ceiling brackets for stabilization and to cover ducting in false ceilings. Weight Standard (kg) MTI CT-125 0, As well as the standard design, the escutcheon plate is available in an ATEX (EX) version. Ø 10 (4X) 3 MVK wall bracket Wall brackets can be special ordered in custom horizontal and vertical lengths. Weight Standard (kg) MVK-125 2, Ø 10 (4X) 232 Ø As well as the standard design, the bracket is available in an ATEX (EX) version.

8 description Friction joints Ball bearing-equipped adjustable friction joints in polypropylene (PP), with guide ring in low friction-treated rubber. Support springs and other component parts in zinc-plated steel or stainless steel. Tubes Made from thin-walled anodised aluminium or from polypropylene. Air-tight damper supplied as standard. ME Standard The standard ME version has polypropylene joints and anodised aluminium tubes. The standard ME version is suitable for evacuating most types of airborne contaminants, e.g. in laboratories, schools, hospitals, the pharmaceutical industry, hairdressing salons and light industrial applications. Delivery Ceiling- Supplied assembled, excluding hood. The MTI or MET MTF ceiling brackets should be ordered separately. Wall- MET Table- MEB Supplied assembled, excluding hood or suction nozzle. MVK-125 wall bracket should be ordered separately. Supplied assembled, with attachment plate for table fitting, excluding hood. The MBF flexible table bracket should be ordered separately. ME PP Polypropylene joints and tube version. All metallic parts that are in contact with the air flow are made of stainless steel. The PP version of the ME is used primarily for evacuating very corrosive contaminants in high concentrations, e.g. in certain laboratories and in the pharmaceutical and chemical industries. When using a PP extractor fitted to a ceiling, we recommend that you order the MTI ceiling bracket with an internal epoxy coating. ME ATEX Conductive polypropylene joints and tubes. All metallic parts that are in contact with the air flow are made of stainless steel. Static electricity is diverted to a separate earth connection. All steel supporting parts are lined in a conductive powder coating. The product meets the requirements of category 2 of the ATEX directive (94/9/EC) for gases and dust. The ATEX version of the ME is suitable for evacuating airborne contaminants where there is a requirement for ATEX-classified products, e.g. laboratories, the chemical and petrochemical industries, gas distribution, and the paint and pharmaceutical industries. Verkstadsvägen 2, Skelleftea, Sweden Tel : , Fax: info@fumex.se

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector ALUMINUM REPAIR CERTIFICATION EQUIPMENT Eliminate hazardous aluminum dust with a Eurovac system BODY REPAIR EQUIPMENT OPTIONS Product Description When repairing an aluminum structured vehicle, it is essential

More information

PERMA arm. Extraction arm. The lowest pressure loss

PERMA arm. Extraction arm. The lowest pressure loss Extraction arm PERMA arm Geovent A/S offers a new extraction arm, the PERMA, in our program of extraction arms. The PERMA arm is suitable for use at hairdressers, dental clinics, jewelers, pharmacies,

More information

A hood is installed at the tip of every suction element to make sure of an efficient extraction. You can choose between different versions.

A hood is installed at the tip of every suction element to make sure of an efficient extraction. You can choose between different versions. 92 TEKA offers a wide range of suction andcollecting elements for various solutions. Our suction arms range from small diameters, e.g. 50 mm for laboratories, dentistry or beauty salons up to large diameters

More information

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS Contents Page User instructions 3-5 General 3 Fan installation 3-4 Maintenance 3 Electrical installation 5 Troubleshooting 5 Technical description 6-8 General

More information

Extraction systems for the electronic industry. Soldering workstations Soldering smoke extraction systems

Extraction systems for the electronic industry. Soldering workstations Soldering smoke extraction systems Extraction systems for the electronic industry Soldering workstations... 99 Soldering smoke extraction systems... 101 Accessories and spare parts... 102 98 Extraction and filter unit for soldering workstations

More information

Optimal work climate with open doors. Industrial air curtains Model IndAC

Optimal work climate with open doors. Industrial air curtains Model IndAC Optimal work climate with open doors Industrial air curtains Model IndAC Industrial air curtain Optimal work climate During loading and unloading the door remains open, without the indoor climate being

More information

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans The Silent Range Pure Elegance & Tranquillity The widest range of ultra quiet silent fans The most advanced SILENT technology delivering the highest extract performance. 1 Your first choice for ventilation

More information

Equipment guide for local exhaust ventilation (LEV)

Equipment guide for local exhaust ventilation (LEV) Nederman equipment guide brochure LEV_Layout 1 29/09/2014 13:43 Page 1 Equipment guide for local exhaust ventilation (LEV) Extraction products, systems and solutions available Nederman is one of the world'

More information

HD 5/11 C Plus. Automatic pressure cut-off. Pump technology

HD 5/11 C Plus. Automatic pressure cut-off. Pump technology HD 5/11 C Plus Compact cold-water high pressure cleaner. With its compact dimensions, robust construction and greatest possible manoeuvrability, this unit is a credit to the compact class. 1 Automatic

More information

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level Clean Air Laminar Flow Ceiling CG 3 Ultra Clean Ventilation System with Unidirectional Flow Draft-free, comfortable room climate Minimal, undisruptive noise level Easy to disinfect housing design with

More information

DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual

DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual EN Content Safety Requirements...3 Transportation...3 Brief Description of the Unit...5 Installation...6

More information

Fume extraction system FEC.

Fume extraction system FEC. TECHNOLOGY FOR THE WELDER S WORLD. Fume extraction system FEC. Weld fume extraction with cyclone technolgy! www.binzel-abicor.com Easy handling! Highest suction power. Fume extraction system FEC Harmful

More information

Operating Instructions

Operating Instructions Operating Instructions Typ TEKA CAREMASTER TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0) 2863 9282-72

More information

User s Manual MATRIX A MATRIX S MATRIX A. Filtro de aspiración Movil Matrix Tel.

User s Manual MATRIX A MATRIX S MATRIX A. Filtro de aspiración Movil Matrix Tel. Filtro de aspiración Movil Matrix 1000 User s Manual Filtering unit Tel. 976 359 352 MATRIX-1000-1-S MATRIX-1000-1-A MATRIX-1000-2-S MATRIX-1000-2-A email. albis@albis.net www.aspiraciondehumos.com KLIMAWENT

More information

Technical Catalog laboratory furniture system

Technical Catalog laboratory furniture system Technical Catalog laboratory furniture system Technical Catalog The new design of our SCALA laboratory furniture program is creating the laboratory of the future. Only when design and functionality effectively

More information

The green and friendly entrance. Comfort air curtains Model CA 2

The green and friendly entrance. Comfort air curtains Model CA 2 The green and friendly entrance Comfort air curtains Model CA 2 Energy saving and userfriendly air curtain Model CA 2 is the newest addition to the series Biddle comfort air curtains. It is Biddle s conviction

More information

Cold water HD 9/18-4 ST

Cold water HD 9/18-4 ST Cold water HD 9/18-4 ST The space-saving stationary high-pressure cleaners from Kärcher with up to 6 supply points can be individually configured according to requirements and impress with low wear and

More information

Factory & Hospital hygiene, Chap 21(7 th edition) Principles of GMP, Chap 23 (8 th edition )

Factory & Hospital hygiene, Chap 21(7 th edition) Principles of GMP, Chap 23 (8 th edition ) Factory & Hospital hygiene, Chap 21(7 th edition) Principles of GMP, Chap 23 (8 th edition ) (Hugo & Russel s Pharmaceutical microbiology) Dr Randa Haddadin ١ Quality: means fitness for purpose, i.e product

More information

ATEX instruction for APP / PAH PAHT G 2-90 / PAH Tech

ATEX instruction for APP / PAH PAHT G 2-90 / PAH Tech AKING ODERN LIVING POSSIBLE Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Instruction ATEX instruction for APP 0.6-10.2 / PAH 2-100 PAHT G 2-90 / PAH 25-80 Tech

More information

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products Fans s for f Life! CA-TD0708 The World s Leading Producer of Air Movement Products TD In-line Mixed Flow Duct Fans Soler & Palau (S&P) USA and Canada are the most recent additions to, and are wholly owned

More information

Halton Rex 600 Basic R6B - Active chilled beam

Halton Rex 600 Basic R6B - Active chilled beam Halton Rex 600 Basic R6B - Active chilled beam Halton Rex 600 Basic chilled beam is: A base version to the combined cooling, heating, and supply air unit for flush installation within a suspended ceiling.

More information

Cold water compact class HD 5/11 C. Standard accessories: Trigger gun Extended highpressure. Technical data

Cold water compact class HD 5/11 C. Standard accessories: Trigger gun Extended highpressure. Technical data Cold water compact class HD 5/11 C Compact cold-water high pressure cleaner. With its compact dimensions, robust construction and greatest possible manoeuvrability, this unit is a credit to the compact

More information

Technical Catalog laboratory furniture system

Technical Catalog laboratory furniture system Technical Catalog laboratory furniture system Technical Catalog The new design of our SCALA range of laboratory furniture will set the trend for future laboratory design. But only if design and functionality

More information

Gas heaters and convectors ROBUR

Gas heaters and convectors ROBUR Gas heaters and convectors ROBUR Table of Contents Robur M general characteristic...3 Robur M dimensions...3 Robur M construction...4 Robur M technical data...5 Robur M installation...6 Robur M accessories...7

More information

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

4 Storage cabinets SCALA

4 Storage cabinets SCALA Storage cabinets Our SCALA laboratory furniture system provides you the greatest possible selection of storage variations for quick access and safe storage. All storage cabinets are variably equipable

More information

hp Dust Collector With Vacuum Attachment

hp Dust Collector With Vacuum Attachment Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Vacuum Hose Reel 881 Ex

Vacuum Hose Reel 881 Ex ATEX approved vacuum hose reel suitable for cleaning explosive dust. The vacuum hose reel 881 Ex facilitates the handling of long and heavy vacuum hoses, and provides tidy and safe storage when they are

More information

CREATING A CLEANER ENVIRONMENT EAZIFLO FUME CAPTURE SYSTEM

CREATING A CLEANER ENVIRONMENT EAZIFLO FUME CAPTURE SYSTEM Dust Collection CREATING A CLEANER ENVIRONMENT EAZIFLO FUME CAPTURE SYSTEM DESCRIPTION Eaziflo is a mobile, self-contained weld fume capture system, designed specifically for removal and filtration of

More information

BRIZA_038. EC MOTOR Briza Hybrid: High performance technology

BRIZA_038. EC MOTOR Briza Hybrid: High performance technology EC MOTOR Briza Hybrid: High performance technology BRIZA_038 Installation into a wall recess (Built In Wall) 2-pipe connection / 4-pipe connection - Heating & cooling - units built-in H 38 cm, D 12 cm

More information

Contents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections

Contents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections Room unit Contents Technical Description of the Air Handling Unit General, Specification... 146 Function, Functional Sections... 147 Control System Control Display, Airflow Control... 148 Temperature Control...

More information

Units for suspended ceilings

Units for suspended ceilings X X testregistrierung Units for suspended ceilings Type, hinged induced air grille, water connections Active chilled beam with two-way air discharge and horizontal heat exchanger, suitable for grid ceilings

More information

1. Oxygen Master 2. Oxygen Sensor 3. Oxygen Refresh Stand-Alone 4. Touch button controls 4. Oxygen Refresh Built-In 5.

1. Oxygen Master 2. Oxygen Sensor 3. Oxygen Refresh Stand-Alone 4. Touch button controls 4. Oxygen Refresh Built-In 5. 77 1 4 3 6 2 5 1. Master 2. Sensor 3. Refresh Stand-Alone 4. Touch button controls 4. Refresh Built-In 5. Exhaust _ System components 1. OXYGEN REFRESH UNITS Built-In Stand-Alone Air freshening unit for

More information

Safety vacuum cleaner with automatic filter cleaning system, 42 l, class L

Safety vacuum cleaner with automatic filter cleaning system, 42 l, class L Safety vacuum cleaner with automatic filter cleaning system, 42 l, class L VCE 44 L AC Order number 444.54 Safety vacuum cleaner with automatic filter cleaning system, 42 l, class L + Adapter plate that

More information

analytical laboratory clear amber bottles clear bottles

analytical laboratory clear amber bottles clear bottles 94 analytical laboratory Manufactured from borosilicate 3.3 which is Autoclavable at 121 C and 1.1 bar for 30 minutes. The angled finishing allows the liquid to flow without any restrictions. Cap has a

More information

A. Codes and Standards that are Standard at the University:

A. Codes and Standards that are Standard at the University: PART 1: GENERAL 1.01 Purpose: 1.02 References: 1.03 Requirements: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The

More information

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours. CERAMIC PUMPS FGP Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours. FGP THE SOPHISTICATED PUMP CONCEPT If you want to solve demanding pumping tasks in the industry

More information

HasconWing. Fixed or variable airfoil profile axial impellers

HasconWing. Fixed or variable airfoil profile axial impellers HasconWing Fixed or variable airfoil profile axial impellers Hascon Engineering has been operating in the ventilation field for more than thirty years and our reliable and high quality axial impellers

More information

Axial flow fan AXICO ANTI-STALL

Axial flow fan AXICO ANTI-STALL Product data sheet: AXICO ANTI-STALL Axial flow fan AXICO ANTI-STALL Model FPAC and FPMC axial flow fans with controllable pitch blades. Air flow range: 3-110 m³/s (10.000 400.000 m³/h). Pressure rise:

More information

XPert Balance and Bulk Powder Enclosures

XPert Balance and Bulk Powder Enclosures XPert Balance and Bulk Powder Enclosures Labconco Product Diversity Glove Boxes Fume Hoods Biological Safety Cabinets Freeze Dryers Glassware Washers Filtered Enclosures Carts & Mobile Benches Centrifugal

More information

Air distribution systems. Opticlean OC-Q...

Air distribution systems. Opticlean OC-Q... Air distribution systems OC-Q... DS 136 E 06.013 Preliminary remarks, mode of operation and construction design Preliminary remarks KRANTZ KOMPONENTEN has developed the OC-Q in order to combine in a single

More information

Domestic & Commercial Fans

Domestic & Commercial Fans Max. airflow l/s Axial Fan Centrifugal Fan Speed Controllable Reversible Airflow Page Number BF IF CF CBF BF 64 * 16 IF 64 * 16 EAF LV 23 * 169 ECF LV 31 * 169 CF 25 * 170 CBF 31 * 170 RVF 0 * * 171 BRAVO

More information

Secuflow laboratory fume cupboards

Secuflow laboratory fume cupboards laboratory fume cupboards More safety, economy and comfort than ever: Our fume cupboards We are continuously working to improve laboratory equipment because being the leader in innovation is no accident.

More information

Technical Catalog laboratory furniture system

Technical Catalog laboratory furniture system Technical Catalog laboratory furniture system Technical Catalog The new design of our SCALA laboratory furniture program is creating the laboratory of the future. Only when design and functionality effectively

More information

Sentry Air Systems, Inc.

Sentry Air Systems, Inc. Sentry Air Systems, Inc. Plastic Fume Extraction Systems Simple Solutions for Cleaner Air. Made in U.S.A. 800.799.4609 www.sentryair.com sales@sentryair.com Hazards of Plastic Fume FUME & PARTICULATE REMOVAL

More information

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility Güntner Info GVX with microox technology 6 525 kw Always a step ahead: microox condenser system with maximum installation flexibility The new standard for flexibility, technology Energy-saving operation

More information

HD 7/11-4 Cage Classic

HD 7/11-4 Cage Classic HD 7/11-4 Cage Classic Long service intervals and high-quality components such as the crankshaft pump with ceramic piston are among the many strengths of the HD 7/11-4 Cage Classic single-phase high-pressure

More information

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams Integrated chilled beams Key figures Connections: 1x mm, 2x mm Airflow: 5-60 l/s Pressure range: 40 - Pa Size: 293 x 200 mm (WxH) Length: 1192 or 1792 mm Total effect: up to 1200W Cumulus is available

More information

Secuflow laboratory fume cupboards

Secuflow laboratory fume cupboards Secuflow laboratory fume cupboards More safety, economy and comfort than ever: Our Secuflow fume cupboards We are continuously working to improve laboratory equipment because being the leader in innovation

More information

Safety vacuum cleaner with automatic filter cleaning system, 30 l, class L

Safety vacuum cleaner with automatic filter cleaning system, 30 l, class L Bahnhofstraße 5 77 Steinheim Phone +49 744 828-0 Fax +49 744 25899 Safety vacuum cleaner with automatic filter cleaning system, 30 l, class L VCE 33 L AC Order number 444. Safety vacuum cleaner with automatic

More information

ovens line elettrodrago for bread and pastry

ovens line elettrodrago for bread and pastry ovens line elettrodrago AVANT for bread and pastry The art of creating heat, since 1929 " We've always thought of heat like a true ingredient of bread. As with the other ingredients, it should be high

More information

Technical Catalogue laboratory furniture system

Technical Catalogue laboratory furniture system Technical Catalogue laboratory furniture system Technical Catalogue The new design of our SCALA range of laboratory furniture will set the trend for future laboratory design. But only if design and functionality

More information

Phenomena up close. Demonstration fume cupboards. Special features

Phenomena up close. Demonstration fume cupboards. Special features FUME CUPBOARDS Demonstration fume cupboards The mobile fume cupboard AeroEM will fascinate audiences in the room. Position your experiments behind safety glass and supply them with gas, water or electricity.

More information

FILTERCUBE 2N We set air in motion

FILTERCUBE 2N We set air in motion FILTERCUBE 2N 2500 Central filter unit. Appropriate to many suction tasks for several working places at the same time for jobs using non-alloyed metals and precious metals, galvanized material and aluminium.

More information

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours. CERAMIC PUMPS FGP Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours. FGP THE SOPHISTICATED PUMP CONCEPT If you want to solve demanding pumping tasks in the industry

More information

HD 6/13 C. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle. 3 Accessory storage

HD 6/13 C. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle. 3 Accessory storage HD 6/13 C Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle. 2 1 Mobility The integrated carrying handle on the front of the machine enable

More information

RFE PLUS RFCE PLUS. Electric Radiator with Digital Control & Programmer. 430mm High Conservatory Electric Radiator with Digital control & Programmer

RFE PLUS RFCE PLUS. Electric Radiator with Digital Control & Programmer. 430mm High Conservatory Electric Radiator with Digital control & Programmer RFE PLUS Electric Radiator with Digital Control & Programmer RFCE PLUS 430mm High Conservatory Electric Radiator with Digital control & Programmer RADIATORS, DETAILS THAT MAKE THE DIFFERENCE ELNUR s quest

More information

Aluminium Curtain Tracks

Aluminium Curtain Tracks Aluminium Curtain Tracks Hand-drawn and Corded Tracks The brand for curtain accessories The brand for curtain accessories Your Curtain Tracks and Renaissance Your time is valuable. So you need to choose

More information

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. with pull-down outlet element DS 4178 E 01.201 Preliminary remarks Materials and designs As a rule, turbulent mixing ventilation is used in cleanrooms to

More information

The power of ventilation

The power of ventilation The power of ventilation LindabAir Handling Unit Ensure the correct flow of fresh air, acceleration at the right rate and exact volume lindab.com 1 lindab air handling units Air Handling Units that maximise

More information

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation BTBa CEILING UNIT FLUSHLINE BTBa FLUSHLINE BTBa is a complete climate system offering immense flexibility. Ideal for large areas with

More information

OPERATING INSTRUCTIONS. HELIOS SAFE INDUSTRY ATEX 1500 Watt COD. EHSAFE Watt COD. EHSAFE20

OPERATING INSTRUCTIONS. HELIOS SAFE INDUSTRY ATEX 1500 Watt COD. EHSAFE Watt COD. EHSAFE20 OPERATING INSTRUCTIONS HELIOS SAFE INDUSTRY ATEX 1500 Watt COD. EHSAFE15 2000 Watt COD. EHSAFE20 HELIOS ELECTRIC INFRARED IRK SAFE INDUSTRY MODEL 1500 Watt (cod. EH SAFE 15) / 2000 Watt (cod. EH SAFE 20)

More information

our contribution for Sealless Magnetic Coupled, Heavy Duty Side-Channel Pumps environmental protection Type SCM PN40

our contribution for Sealless Magnetic Coupled, Heavy Duty Side-Channel Pumps environmental protection Type SCM PN40 Sealless Magnetic Coupled, Heavy Duty Side-Channel Pumps our contribution for environmental protection Type SCM PN40 General The DICKOW-pump, type SCM, is a selfpriming horizontal side-channel pump with

More information

Models SCA and SCB. ceiling-mount cartridge dust collectors. Model SCA. Model SCB

Models SCA and SCB. ceiling-mount cartridge dust collectors. Model SCA. Model SCB Models SCA and SCB Model SCB Model SCA ceiling-mount cartridge dust collectors MODELS SCA AND SCB Industrial Dust Collectors for Ambient Air and Contaminants directly at the Source. INNOVATIVE ANSWER Need

More information

TRS 292, ST ST-97

TRS 292, ST ST-97 Floor cleaner 12 High pressure nozzles 292, 285 Mosmatic cleaning head TRS 297 Mosmatic floor cleaner 297 Mosmatic rotor arms 297 Mosmatic surface cleaner with air recovery system and integrated gum remover

More information

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Purge Ventilation Unit. Product Manual. ventilation systems TP625 EN Purge Ventilation Unit TP625 Product Manual ventilation systems Warnings, Safety Information and Guidance Important Information Important: read these instructions fully before the installation of this

More information

INSTALLATION FB T: +44 (0) F: +44 (0) E: W:

INSTALLATION FB T: +44 (0) F: +44 (0) E: W: INSTALLATION FB 1 Contents User instructions General Fan installation Maintenance Electrical installation Troubleshooting Technical description General Classification Technical specification Manufacturer

More information

Twin radial blower DRG 1200 with oval resistor, 12 and 24 Volt versions

Twin radial blower DRG 1200 with oval resistor, 12 and 24 Volt versions 1/8 Twin radial blower DRG 1200 with oval resistor, 12 and 24 Volt versions Content: 1 Safety advises 2 Usage 3 Construction of the DRG 1200 4 Function 5 Installation, dimensions and hole pattern 6 Technical

More information

Technical Ventilation

Technical Ventilation About ventilation of cabinets Nearly all governments place duties on employers to eliminate or control the risks from explosive atmospheres in the workplace. When it comes to storing flammables, the risk

More information

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI Hydraulic Institute Standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Twin radial blower DRG 1200

Twin radial blower DRG 1200 1/7 Twin radial blower DRG 1200 Content: 1 Safety advises 2 Usage 3 Construction of the DRG 1200 4 Function 5 Installation, dimension and hole pattern 6 Technical data 7 Characteristic curve 8 Validation

More information

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM 0,7 kw 5,2 kw 1,6 kw 10,2 kw 130 m 3 /h 830 m 3 /h SLIM SLIMxx0 vertical with cabinet bottom vertical Available also with feet SLIMxx8 SLIMxx5 SLIMxx4 SLIMxx9

More information

Cold water compact class HD 5/15 C

Cold water compact class HD 5/15 C Cold water compact class HD 5/15 C Cold-water pressure washer for daily commercial use. With its compact dimensions, robust construction and greatest possible manoeuvrability, this unit is a credit to

More information

L a b o r a t o r y E q u i p m e n t C a t a l o g

L a b o r a t o r y E q u i p m e n t C a t a l o g B y S t a t i t e c h L a b o r a t o r y E q u i p m e n t C a t a l o g Fume Cupboards & Ductless Fume Hoods Biological Safety Cabinets Laminar Flow Clean Benches PCR Cabinets Complete Laboratory Furnishing

More information

Technical Catalogue laboratory furniture system

Technical Catalogue laboratory furniture system Technical Catalogue laboratory furniture system Technical Catalogue The design of our SCALA range of laboratory furniture will set the trend for future laboratory design. But only if design and functionality

More information

WOLF VENTILATION SYSTEM PRICE LIST

WOLF VENTILATION SYSTEM PRICE LIST VENTILATION SYSTEM PRICE LIST JANUARY 2018 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build and modernisation

More information

Axial fans The right fan for every house

Axial fans The right fan for every house Axial fans The right fan for every house Axial fans with frame for incorporation into walls Big Dutchman offers a wide range of axial fan types. This variety allows us to meet all the climate requirements

More information

Air distribution systems. Opticlean OC-Q... DS 4136 E /1

Air distribution systems. Opticlean OC-Q... DS 4136 E /1 Air distribution systems Opticlean OC-Q... DS 136 E 06.13/1 Preliminary remarks, mode of operation and construction design Preliminary remarks KRANTZ KOMPONENTEN has developed the Opticlean OC-Q in order

More information

Fume Extraction Workstation

Fume Extraction Workstation FUMINATOR Fume Extraction Workstation FXT300 Users Guide Copyright 2001 EDSYN, INC. FUMINATOR Fume Extraction Systems FXT-300 Fume Extraction Workstation - OPERATOR USER GUIDE TABLE OF CONTENTS Introduction..................................3

More information

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual DOMEKT ReGO 400VE(W)-B Series Air Handling Units EN Content Safety Requirements...3 Transportation...3 Brief Description of the Unit...5 Installation...6 Maintenance...11 Technical Information......13

More information

WHY SULLAIR? For more information on the IHI-Sullair joint venture, please visit 2,000th IHI-Sullair centrifugal

WHY SULLAIR? For more information on the IHI-Sullair joint venture, please visit   2,000th IHI-Sullair centrifugal WHY SULLAIR? Since 2004 Sullair has been part of IHI-Sullair, a joint venture focused on developing and producing high performance centrifugal compressors. Those compressor models, with more than a decade

More information

FULL RANGE of products for the protection of boilers and water heating loops SLUDGE FILTERS FDM-1P / FDM-2 / FDM-3

FULL RANGE of products for the protection of boilers and water heating loops SLUDGE FILTERS FDM-1P / FDM-2 / FDM-3 FULL RANGE of products for the protection of boilers and water heating loops SLUDGE FILTERS FDM-1P / FDM-2 / FDM-3 ACID CONDENSATE NEUTRALISERS NEUTRAL COND / NEUTRAL MINI FDM SLUDGE FILTERS The FDM sludge

More information

High pressure cleaning heads cleanliness all around

High pressure cleaning heads cleanliness all around High pressure cleaning heads cleanliness all around 2 3 Cleaning at the highest level Perfect internal cleaning of vessels with the URACA TWK system In industries such as the chemical, petrochemical, synthetics,

More information

Pipe Support Systems

Pipe Support Systems Pipe Support Systems Many years of experience in manufacturing pipe support systems means the TIO range is all but limitless. Whatever the application, there will be a pipe system to solve your problem.

More information

Safety vacuum drying oven for flammable solvents

Safety vacuum drying oven for flammable solvents VDL series 53 Vacuum drying ovens Safety vacuum drying oven for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with

More information

Cold water compact class HD 5/17 C

Cold water compact class HD 5/17 C Cold water compact class HD 5/17 C Cold-water pressure washer for daily commercial use. With its compact dimensions, robust construction and greatest possible manoeuvrability, this unit is a credit to

More information

Operating Instructions

Operating Instructions Operating Instructions TEKA Cartmaster Type PF-W 1, PF-W 2 TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0)

More information

WHHR Midi & Midi Lite

WHHR Midi & Midi Lite WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page

More information

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59 SOUND-INSULATED FAN OPERATION MANUAL _v.1(2)-en.indd 1 10.08.2015 15:20:59 CONTENT Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 3 Fan design 4 Delivery

More information

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini... Contents How to choose Recovery Ventilation type?............................................3 How do HRV, ERV and TRV Systems work?............................................4 Types of installations..............................................................5

More information

G Installation manual Solitude - dmev unit

G Installation manual Solitude - dmev unit G G Installation manual Solitude - dmev unit Read this manual carefully before using the product and keep it in a safe place for reference. This product was constructed up to standard and in compliance

More information

CONDOR. Supply air ceiling QUICK FACTS

CONDOR. Supply air ceiling QUICK FACTS Supply air ceiling QUICK FACTS 00% flexible spread pattern High induction rate Can be cleaned Diffuser modules 595 x 595 mm Available in alternative colours VariZon air distribution system A I R F L O

More information

HDS 5/11 UX. Entry-level, highly portable hot water pressure cleaner with integrated hose reel. Integrated hose reel. Innovative upright design

HDS 5/11 UX. Entry-level, highly portable hot water pressure cleaner with integrated hose reel. Integrated hose reel. Innovative upright design HDS 5/11 UX Entry-level, highly portable hot water pressure cleaner with integrated hose reel 1 2 3 4 1 2 Integrated hose reel Convenient, secure pressure hose storage. Ensures ergonomic operation. Fine-mesh

More information

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique

More information

HD 5/12 C Plus. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle.

HD 5/12 C Plus. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle. HD 5/12 C Plus Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle. 1 Mobility 3 Accessory storage The integrated carrying handle on the

More information

EHH SERIES DRAW THROUGH FAN COILS CFM

EHH SERIES DRAW THROUGH FAN COILS CFM EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE

More information

Filters & Centrifugal Separators

Filters & Centrifugal Separators www.kaeser.com s & Centrifugal Separators Flow rates 0.8 to 8 m³/min Why use compressed air filters? On average, a compressor sucks in up to 90 million particles of dirt, hydrocarbons, viruses and bacteria

More information

FAN ENGINEERING. Sealing of Fan Housings

FAN ENGINEERING. Sealing of Fan Housings FAN ENGINEERING Information and Recommendations for the Engineer FE-700 Sealing of Fan Housings Introduction A variety of options are offered by fan manufacturers to seal fan housings. Sealing the housing

More information

ECV SP GUE ALO CAT ICAL TECHN

ECV SP GUE ALO CAT ICAL TECHN TECHNICAL CATALOGUE ECV SP TAILOR MADE FOR UNITS FITTED WITH VRF SYSTEMS Models: 1001 1502 1602 2003 2303 10.16 Ref. 207609 Rev.105 CONTENT INTRODUCTION... 3 GENERAL DESCRIPTION... 3 CABINET... 3 HEAT

More information

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities Pulse Jet ASTEC PULSE JET BAGHOUSE for Asphalt Facilities ASTEC PULSE JET BAGHOUSE FOR ASPHALT MIXING PLANTS Astec baghouses deliver superior performance and efficiency, while helping your plant meet

More information