Be sure to support the lower section using a crane or setting it on temporary blocks, etc..

Size: px
Start display at page:

Download "Be sure to support the lower section using a crane or setting it on temporary blocks, etc.."

Transcription

1 6. INSTALLATION Position Lower Dryer at Location Position the lower dryer section at the final location. Be sure to support the lower section using a crane or setting it on temporary blocks, etc.. Anchor Lower To Pad / Foundation Most dryer system utilize a NECO support leg option. Some dryer systems utilize both concrete piers and either the NECO legs or customer supplied legs. No matter the method, double-check and verify proper assembly - make sure system is secure. Check & Verify ALL anchor attachment systems before installing optional leg kit or the addition of any upper dryer sections. DETERMINE NEXT STEP -- If the dryer is configured for a NECO support leg system, proceed to the following section. If other means are being used, after the lower section achor system is completed and verified continue with Stack and Secure s. 55

2 Install NECO Leg Kit (OPTIONAL) NOTE: Skip this section if the dryer system does not utilize the optional NECO lifting legs. OVERVIEW The optional lifting leg system is based on requirements that vary with the size and capacity of the dryer. Leg kits are available in 24, 48, or 60 lengths. Most dryer systems with legs are set atop a concrete slab. Some do not have a slab, but have individual foundation piers for support and anchoring. The dryer should also be secured in a secondary manner (guy wires, for example). This is especially true for taller dryers, which have greater surface area exposed to the wind. Refer to Figure 9B and the descriptions on the following page to identify the leg styles and locations: WARNING Be sure to support the dryer s lower section assembly by hanging from a crane or sitting on blocks prior to installing ANY lifting legs. WARNING Torque all attachment hardware to the proper values -- 1/2 grade 5 bolts -- to 65 ft-lbs torque value 5/8 grade 5 bolts -- to 135 ft-lbs torque value A LEGS OUTER & INNER B LEG(S) CENTER C LEGS COLUMN Figure 9B - Working dryer setup - with optional NECO leg kit. 56

3 Leg styles and location: A Side legs are located around the outside & inside perimeter of the dryer. B Center leg(s) are located in the area where the tongue meets the dryer frame and can be a single or double leg setup - based on the dryer height and load requirements. Table 9T1 - A Side Leg (Outter & Inner) ATTENTION - Use 5/8 x 1 1/2 bolts, flat washer, and flange nut Part Elevation Length Number inches mm inches mm / / / C Column legs (if needed) are located to provide column support for the platforms. Note: Single blower dryers DO NOT require these supports because there are no upper platforms. 5/8" WHIZLOCK NUT 5/8" X 1 1/2" BOLT 5/8" FLATWASHER WARNING Be sure to torque all legs properly as they are being installed - then, double-check torque values upon completion. Use shims, if needed -- Figure 9C - Frame to Side Leg Hardware Arrangement The extra hole is used for extra high capacity frames. A A Outer Legs & Inner Legs Refer to Figures 9C & 9D, with Table 9T1: NOTE: Extra-high capacity dryers(ehc) use the 2nd set of holes for added strength. Figure 9D - A attachment hole locations While the dryer lower section is hanging from a crane or setting on blocks: bolt the A outer side legs only around the outside perimeter of the dryer frame. Once the A side legs are mounted around the outside, go ahead and mount the inner A side legs to the inside frame positions. 57 B Center Leg(s) - Single or Double Dryers with seven tiers or less will use the B Single Leg style as shown in Figure 9E, with part numbers for available heights shown in Table 9T2.

4 C Column Support Legs B NOTE: Dryers with only one section (one blower) do not use column support legs. Part numbers for C Column Support Legs are shown in Table 9T4. Bolt the required column support leg to the I-beam on top of the dryer tongue using ½ x 1½ bolts and hardware as shown in Figure 9G. Figure 9E - Center Single Leg Attachment Table 9T2. B Center Single Leg ATTENTION - Use 1/2 x 1 1/2 bolts, flat & lock washer, and nut Part Number Elevation Length inches mm inches mm / / Dryers with more then seven tiers will use the B Double Leg style, as shown in Figure 9F, with part numbers for available heights shown in Table 9T3. B Figure 9F - Center Double Leg Attachment Figure 9G - Column (Platform) Support Attachment Table 9T3. B Center Double Leg ATTENTION - Use 1/2 x 1 1/2 bolts, flat & lock washer, and nut Part Elevation Length Number inches mm inches mm / / Table 9T4. C Platform Support Legs ATTENTION - Use 1/2 x 1 1/2 bolts, flat & lock washer, and nut Part Elevation Length Number inches mm inches mm / / /8 1965

5 Stack & Secure s WARNING Do NOT stack any additional sections on top of the bottom section unless it is secured to the foundation. ATTENTION -- The following stacking information is applicable for: Upper dryer sections - made up of 3-6 tier levels Top-most filling dryer section - made up of 1-2 tier levels and the topside filling system. NOTE: All styles of fill systems, including catwalk and / or safety cage, should be completely assembled on the ground and then lifted into position and secured. OVERVIEW Refer to APPENDIX - Dryer Layout Configurations for specifics on sections and section stacking order. Depending on the dryer model configuration, certain parts are installed at the factory and certain parts require installation as the sections are stacked. STACKING ORDER - If your dryer has multiple sections, make sure you stack the sections in the proper order. The dryer section with the cord set labeled 1 is the longest cord and would be the upper-most section located the furthest away from the control panel. Position the rest likewise - #2 cord set would be the next dryer section toward the bottom and so on. LP FUELED DRYERS: Be carefull of the LP vaporizer coils when stacking sections - they stick up slightly and can be damaged!!! PLATFORM SUPPORT COLUMNS: These are shipped wired to the platforms and should be mounted at the bottom to the Platform Support Angles prior to adding the next dryer section. LADDER SECTIONS: If ladder section lengths are level with the top tier of a dryer section, they are factory mounted. If they are not level with the shipped top tier, the ladder section for that section is wired to the platform floor - see Ladder Installation section for details. NEXT SECTION PLATFORM SUPPORT COLUMNS BOTTOM SECTION 59

6 Remove Lifting Lug Top Plates Refer to Figure 9H: Prior to stacking any dryer sections, remove all # lifting lug top plates from corners. - if these are left in place, the next sections flange lips will NOT position correctly. ALL of the factory mounted Corner Support Gussets MUST STAY ATTACHED. NOTE: Lifting lugs can be left in place or removed. If removed, replace the hardware Lifting Lug Top Plate , L Corner Support Gussets Install Air Plenum End Panel Spacers Figure 9H - Remove lifting lug top plates Refer to Figure 9J: Position # plenum end panel spacer for installation where ANY two air plenum end panels meet together. Position as shown and secure when outside flange lips are bolted together. End Plenum Spacer Plenum End Panel 1/4" x 3/4" Bolt 1/4" Flatwasher End Plenum Spacer 1/4" Whizlock Nut Figure 9J - Install spacers between any two air plenum end panels 60

7 Install Transition / Plenum Fill Strips Refer to Figures 9K: When the transition lip is level with the dryer sections top tier AND the next section to stack has a plenum end panel, use a # transition / plenum fill strip to secure the top of the transition to the underside lip of that next stacks plenum end panel. Use 1/4 x 3/4 HB, FW, & WL to secure the strip at both edges. Top of Transition Transition/Plenum Fill Strip Install Platform Support Columns Refer to Figure 9L1 & 9L2 with Table 9T5: SKIP to next step if the dryer does NOT have multiple platforms. The LOWER support column weldment mounts directly to the beam. ALL upper sections use UPPER support columns & mount using # support angles. The support column angles are factory mounted and the support columns for that section are wired to the platform for shipment. ATTENTION - The support columns must be in position PRIOR to the installation of the next dryer section. Figures 9K - Install transition / plenum fill strip TABLE 9T5 SUPPORT COLUMN SIZE REQUIREMENTS LOCATION & TIER SPAN COLUMN PART # COLUMN LENGTH ( REFERENCE) LOWER - 3 TIER /8 UPPER - 3 TIER /16 LOWER - 4 TIER /8 UPPER - 4 TIER /16 LOWER - 5 TIER /8 UPPER - 5 TIER /16 LOWER - 6 TIER /8 UPPER - 6 TIER /16 LOWER SUPPORT COLUMN FLANGE WELDMENT DRAWING NO SUPPORT ANGLE # USE 1/2 x 1-1/2 BOLTS & HARDWARE USED ON LOWEST SECTION ONLY USE 1/2 x 5-1/2 BOLTS & HARDWARE TOLERANCES TITLE UNLESS OTHERWISE SPECIFIED DECIMALS (.X) (.XX) Figure 9L1 - LOWER column with flange (.XXX) ` Figure 9L2 - UPPER column with support angles ` ` weldment.015 LOWER FRACTIONS ` 1/16 MATERIAL ANGLES ` 1~ DIMENSIONS IN INCHES UNLESS OTHERWISE SPECIFIED SIZE DRAWN BY A Division of 61 DATE IT IS ISSUED IN CONFIDENCE FOR A Dfort 7/8/2013 N E C O GLOBAL Industries Inc. WEIGHT DRAWING NO. REV NORTH 45TH STREET - OMAHA, NEBRASKA N/A NECO, a division of GLOBAL Industries Inc., CLAIMS PROPRIETARY RIGHTS IN THE INFORMATION DISCLOSED ON THIS DRAWING. ENGINEERING INFORMATION ONLY AND MAY NOT BE REPRODUCED OR USED TO MANUFACTURE ANYTHING SHOWN HEREON WITHOUT DIRECT WRITTEN PERMISSION FROM NECO TO THE USER. SUPPORT COLUMN WLD 5-T

8 Raise the next section & Lower into Position Either MINIMIZE strap angles or use a spreader system to raise the sections. Use the support columns as guides and lower the section into initial position. Ensure that the lowering flange lips overlap properly all around. USE SPREADER SYSTEM GUIDE LINES Refer to Figure 9M: NOTE: Do Not remove crane from supporting the load until all assembly / installation for that section is complete. Line up flange lips and secure the four corners first to ensure position is held - proceed with following steps 9N - 9R, then make sure all bolts are present and tight. 1/4" x 3/4" Bolt 1/4" Flatwasher ALIGNMENT PUNCH HELPS CENTER HOLES 1/4" Whizlock Nut Figure 9M - Basic Outer / Inner Lip Connection 62

9 Secure Platform Support Columns Refer to Figures 9N: Using 1/2 x 5-1/2 bolts and hardware, secure the support columns to the # support tabs fastened to the cross support tube. CROSS SUPPORT TUBE ATTENTION Note orientation of splice plates. Figure 9N - Secure top of Platform Support Legs Install Body Braces Refer to Figures 9O: Position and bolt a # Body Brace under the overlapped outside and inside flange lips, centered directly under ALL tier splices. Do ALL exterior braces first. NOTE: On model #D24108 shipped in sections (NOT assembled and towed) a divider floor will be installed in the plenum - the divider floor provides the needed support, so the INTERIOR body section braces are not needed for that level ONLY. 1/4" x 3/4" Bolt 1/4" Flatwasher Body Brace 1/4" Whizlock Nut Figure 9O - Body Brace Connection 63

10 Install (Model #24108 ONLY) NOTE: Skip this section if the dryer is NOT a model #D24108 AND the two sections were NOT assembled at the factory and towed to location as one unit. All other models # s have the divider floor(s) installed at the factory - see APPENDIX - Dryer Layout Configurations Refer to Figure 9P: Lay the divider floor sections in position - oriented so that divider door is closest to the rear access plenum door. Note the locations for the floor braces - these are at all floor panel joints and at mid-span for the longer floor panels. The mid-span floor braces can be installed prior to laying out panels Sheet 77" Sheets 68" Sheet 77" Slide Door Right Seal Door Sheet 39" Slide Door Left Seal Figure 9P - Position floor panels - Locate brace poitions Refer to Figure 9Q: Secure the floor panels to the overlapped interior tier lips using 1/4 hardware. Rivet # floor braces to the floor panels with the rivets facing down. Figure 9Q - Bolt on floor plates & rivet braces 64

11 Refer to Figure 9R: At the end of the divider floor, bolt in the # right & # left door seals. Position the # right & # left gussets at approximate mid-length of the door seals and using them as a template, drill holes & secure with 3/16 rivets. Using 1/4 hardware, bolt on the # door slides & slide the # divider door into place. Slide Door Seal 1/4" x 3/4" Bolt 1/4" Flatwasher 3/16" Rivet Door 1/4" x 3/4" Bolt 1/4" Flatwasher Seal - Right Seal - Left 3/16" Drill 1/4" Whizlock Nut Figure 6R - Install divider door system Door Slide Gusset - Left Gusset - Right Attach Cross Braces Refer to Figure 6L: NOTE: Cross brace installation is NOT done if THAT tier level has a divider floor or cooling floor. Either of these floor structures provide the necessary cross stability - skip to next step. Using 1/4 hardware, attach # cross braces at or near every inside splice plate location. CROSS BRACE INSIDE SPLICE PLATES Figure 6L - Attach body section cross braces 65

12 Optional Removal of Platform Braces / Lifting Lugs Refer to Figure 9S: NOTE: The following items can be removed AFTER the dryer section has been stacked and secured. The platform shipping braces can either be left in place or removed. The lifting lugs can either be left in place or removed. Lifting Lugs Platform Braces Figure 9S- Platform Braces & Lifting Lugs can be removed or left in place Be sure to replace all hardware removed if either of these are taken off Attach Ladder s OVERVIEW Depending on the dryer configuration, NECO installs all possible ladder mount brackets and also ladder sections - IF the ladder section is even with the bottom & top of that dryer section for shipping purposes. Mounting brackets can not be installed if they need to be located at same level where two sections stack together. If a dryer ladder section needs to be shipped un-installed it is secured to the platform of that dryer section. See APPENDIX - Dryer Layout Configurations for information on ladder bracket attachment with the necessary ladder section lengths. The 10 (#040370) & 8 (#040369) ladder sections include two ladder brackets with each section supplied. The 4 (#044117) section includes one ladder bracket and is used only as the top-most section in the ladder system when required and will always have to be installed. Note that the ladder mounting brackets can NOT be in the same location as the ladder splice plates - or, where two ladders fit together. Refer to APPENDIX - Dryer Layout Configurations. The top-most section of ladder (10, 8, or 4 ) attaches to the # ladder connection plates of the safety cage system using # ladder clips and 3/8 hardware. It is suggested to either add each ladder section as the dryer sections are installed upward or to wait until all dryer sections and topside filling section have been installed. 66

13 Refer to Figure 9T: NOTE: For dryers with a roof and catwalk system, the 6 dimension from the edge of tier to the # ladder bracket edge should be held closely or the # ladder attachment brackets will not match up correctly. When ever possible, the ladder brackets should be positioned against the lip of a tier section to provide alignment and additional stability. NOTE: Ladder attachment brackets are positioned above or below any ladder section splice and can NOT be located at the same level or position as the ladder splices. Drill 3/8" (10mm) Holes 6" (152mm) Figure 9T - Transfer drill holes to mount Ladder Brackets 67

14 Refer to Figure 9U: NOTE: Ladder brackets can NOT be positioned at either end of any ladder section where the ladder splices are used to secure ladder sections together. Fasten the ladder sections to each bracket using two # ladder clips per bracket. 3/8" FLATWASHER 3/8" LOCK WASHER 3/8" NUT 6" (152mm) FROM OUTSIDE OF TIER TO LADDER # LADDER BRACKET 3/8" FLATWASHER 3/8" LOCK WASHER 3/8" NUT 3/8" x 1" BOLT (3X) 3/8" FLATWASHER 3/8" x 1 1/2" CARRIAGE BOLT # LADDER CLIP (2 PER LADDER BRACKET) Figure 9U - Bolt on Ladder Refer to Figure 9V: Between ladder sections, place a # ladder splice into each ladder leg as shown so that both sections are aligned and securely bolted together. # LADDER SPLICE 3/8" x 1" BOLT 3/8" FLATWASHER (2X) 3/8" LOCK WASHER 3/8" NUT LADDER SECTION Figure 9V - Bolt ladder sections together with ladder splice 68

15 Install Topside Filling WARNING Be sure to utilize spreader bars or similalr means to properly lift the unit. Main lift component should be vertical - do not use sharp angles on strapping!! Refer to Figure 9W: NOTE: Assembly of the topside filling section, attached to the topmost tier section, should have been done at ground level. Ensure the topside system is completed to this level before proceeding further. Make sure the # lifting lug top plates were removed for the section being stacked upon. Lift the completed topside filling section as one completed unit - use guide lines to assist in positioning. Figure 9W - Lift assembled topside filling section Refer to Figure 9X: NOTE: Be sure the safety cage # ladder attachment brackets or final lader section line up correctly with the lower existing ladder sections upon final positining. Install into final position and secure Reference Figures 6J thru 6V and complete all that are necessary to secure the section. NOTE: In most cases, the top-most ladder section is a 4 section and already attached to the safety cage attachment brackets - use ladder clips to secure the two ladder sections together. For some models, the final ladder section may be 8 or 10 and need to be installed to the safety cage ladder attachment brackets. Figure 9X - Install into final position and secure # ATTACHMENT BRACKET Refer to Figure 9Y: Using 3/8 hardware, finish connection of ladder system to the cage ladder connection brackets. # LADDER CLIP 69 Figure 9Y - Finish ladder connection

16 7. FINAL SYSTEM HOOKUP Adjust Control Box Height Refer to Figure 7A: NOTE: Support the weight of the control panel with a forklift as you adjust its height. Loosen the fasteners that hold the control panel in place. The vertical guide rails can also be adjusted upward or downward. Position the control panel at a comfortable operator height and secure in position. Figure 7A - Adjust the height of the control box Final Electrical Hookup WARNING NECO recommends hiring an expert for proper advise, accurate paperwork, and safe procedures to complete electrical work in conformance with local codes. The customer is responsible for providing wiring materials & labor to the dryer system. A properly sized fused disconnect box must be in place PRIOR to finall connections are made to the dryer control box and all personell should know the location and how to operate it. 70

17 Refer to Figure 7B: All cables that can be pre-routed and connected are completed at the factory. The upper Moisture Sensor cable will need to be routed and connected to the correct position labeled on the lower-right side of control box. Figure 7B - Identify cords & route cords - see panel cable connection callouts 71

18 Blower Motor Wire(s) Refer to Figure 7C & 7D: Attach the cords through the holes in the left side of the control panel, using proper conduit connectors / clamps. Blower #1 starts at the top - See APPENDIX - Dryer Layout Configurations for additional information and identification of section (blower) numbers Connect each blower system to the same numbered starter package within the main control following the three phase (3P) example shown below : Single Phase (1P) Wiring: Connect wires T1 & T2 into the bottom of the respective starter(s). Note that T3 loops from the lower-middle postion back up to the upper-right position to provide internal feedback within the control system. Connect the green ground wire to the ground terminal in the Control Box. Three Phase (3P) Wiring: Connect wires T1, T2, & T3 into the bottom of the respective starter(s). Connect the green ground wire to the ground terminal in the Control Box. L1 L2 L3 L1 L2 L3 SINGLE PHASE (1P) MOTOR STARTER THREE PHASE (3P) MOTOR STARTER T1 T3 T2 T1 T2 T3 BLOWER # MOTOR STARTER BLOWER # MOTOR STARTER Figure 7C - Single phase wiring Figure 7D - Three phase wiring 72

19 Thermocouple Wire(s) Refer to Figure 7E: The thermocouple wire and high temp bulb are factory mounted for each dryer section. The data from these is transmitted through the grey communications cable(s) to the PLC unit within the main control box. HIGH TEMP BULB THERMOCOUPLE WIRE Figure 7E - Position Thermocouple Wire(s) Burner Box Cables(s) Refer to Figure 7F: The grey cable entering left side of the burner box(s) is pre-wired at NECO from each modulating motor and controls the flow of fuel through the butterfly valve. The yellow burner cable(s) & the grey communication cable(s) are used between burner box(s) and also from the lowest burner box to the main control box. The cable plugs directly into the top burner box - multiple burner dryer s would use the T connector for all units below. YELLOW BURNER CABLE GREY COMMUNICATIONS CABLE 73 Figure 7F - Burner Box Connections

20 Fill Switch & Low Switch Location The installation location of the Fill & Low switches depends upon the style of fill and configuration of the intake grain supply. The various installation positions come from the factory covered with a # cover plate. Determine the correct switch position for the equipment configuration, install the switches, and connect the wiring as shown. ROOF WITH GRAVITY FILL SYSTEM Gravity fill systems intake grain at the center - the intake auger system must match to this location. THE FOLLOWING POSITIONS SHOULD STAY COVERED THE ROUND POSITIONS IN THE ANGLED END ROOF PANELS. 2. the ROUND AND SQUARE POSITIONS IN THE TOP TIER END PANELS. 3. TOTAL POSITIONS TO REMAIN COVERED ARE 4X ROUND & 2X SQUARE. FILL AUGER EXIT CHUTE NEEDS TO MATCH UP TO THIS FLANGE FILL DRYER SWITCH FLANGE IS 30 DEG. LOW DRYER SWITCH FLANGE IS 45 DEG. #059167R ROTARY SWITCH HOLE COVER PLATE # NOTE: FOR GRAVITY FEED SYSTEMS, THE FILL & LOW DRYER SWITCH ARE IDENTICAL, EXCEPT FOR THE ANGLE OF THE MOUNTING FLANGE. 74

21 Fill Dryer Switch - Gravity Fill System FILL DRYER SWITCH # Low Dryer Switch - Gravity Fill System LOW DRYER SWITCH #

22 LEVEL AUGER FILL SYSTEM OVERVIEW Grain intake position must be a minimum of 2 from either end of the dryer. Factory configuration, per motor cable length and catwalk access, has the level auger motor located at the front end of the dryer closest to the control box. The Fill Dryer Switch and the Low Dryer Switch must be located at the OPPOSITE end of intake grain entry for correct operation. Standard auger motor rotation brings the intake grain FORWARD from a grain entry position located at the rear end of the dryer. Reversed auger rotation results in the opposite. STANDARD AUGER MOTOR ROTATION PUSHES GRAIN TOWARD FRONT OF DRYER INTAKE GRAIN AT REAR (2 FT FROM END) REAR OF DRYER FILL & LOW SWITCHES AT OPPOSITE END OF FILLING FRONT OF DRYER INTAKE GRAIN AT FRONT (2 FT FROM END) REVERSE THE AUGER MOTOR ROTATION TO PUSH GRAIN TOWARD REAR OF DRYER 76

23 ROOF WITH LEVEL AUGER SYSTEM Fill Dryer Switch FILL DRYER SWITCH # COVER PLATE # FRONT OF DRYER Low Dryer Switch LOW DRYER SWITCH #

24 GARNER (OPEN TOP) WITH LEVEL AUGER SYSTEM NOTE: Be sure to install the Fill Dryer Switch & Low Dryer Switch at the end of dryer OPPOSITE the grain intake into the level auger system. The example below shows the Fill & Low switches mounted at the front of dryer for intake grain entry at the rear of dryer. Be sure to use # cover plates for these positions at other end. Fill Dryer Switch & Low Dryer Switch The Fill Dryer Switch mounts in the angled bracket / mount plate assembly - see circled detail area. The Low Dryer Switch mounts in the top tier end panel - install a # cover plate to close off the empty Low switch postion at opposite end.. FILL DRYER SWITCH LOCATION (SWITCH NOT SHOWN) # FRONT OF DRYER LOW DRYER SWITCH # (SEE MOUNTING NOTE) SWITCH BRACKET DETAIL NOTE: BE SURE TO MOUNT SO THAT SWITCH IS IN DOWNWARD POSITION TO HELP REDUCE ANY MOISTURE PROBLEMS. SPECIAL BRACKET POSTION THE ANGLE BRACKETS AND MOUNT PLATE WITH ATTACHED FILL DRYER SWITCH NEEDS TO BE POSITIONED SO THAT THE ROTARY VANES ARE FACING THE INCOMING FLOW OF GRAIN. A GOOD STARTING POINT IS TO SET THE UNIT AT A SLIGHT ANGLE BELOW HORIZONTAL. FINAL POSITIONING IS DONE DURING EQUIPMENT STARTUP. 78

25 Connect Fill Switch & Low Switch Refer to Figure 7G: The upper-most dryer section burner box will have the TWO cables (one YELLOW & one GREY) coiled and marked Fill and Low. Figure 7G - Fill & Low Switch Cables These standard lengths are sufficient for all styles of fill where the two switches are located at the front of the dryer. It may be necessary to use the extension cables provided when the two switches are located at the rear of the dryer. 79

26 Connect Moisture Sensors Overview The combination sensing unit shown has a moisture sensing fin with the temperature sensing probe directly below it. They provide CURRENT READING values to the DryerMaster system. One of these sensing units is located at the top of the dryer for gathering INLET values and another is located within the grain exit chute to gather OUTLET values. MOISTURE FIN TEMPERATURE PROBE CONNECTION IS WITH A GRAY 5-PIN x 20M LG CABLE FROM THE MAIN CONTROL CABINET. Open Top (Garner) Inlet Moisture Sensor NOTE: The inlet sensor needs to be mounted at the OPPOSITE end from the grain intake. Remove the rectangular cover from the end OPPOSITE the grain intake and mount the moisture sensor for inlet grain. Connect the cable marked Inlet Moisture - if the grain intake is at the front (control panel) end, a cable extension is needed to reach the top-rear level. INLET MOISTURE SENSOR (SEE NOTE) 80

27 Roof style Inlet Moisture Sensor NOTE: For Roof with Gravity Feed or Roof with Level Auger fill systems. The Inlet sensor position is located on the catwalk side of the roof - see hatch style door at the end of catwalk for access. Mount the inlet sensor in the housing and connect the cable marked Inlet Moisture. CATWALK HATCH ACCESS DOOR MOISTURE SENSOR Outlet Moisture Sensor / Sample Button NOTE: Outlet moisture sensor / sample housing can be left-hand, center, or right-hand mounted onto the rear cross auger system. Mount the sensor in the housing and connect the cable marked Outlet Moisture. Mount the sample button and connect with the cable marked Sample Button. SAMPLE BUTTON 81

28 Discharge Plugged Sensor The discharge plugged sensor(#059118) will activate if the discharge becomes plugged - causing the hinged lid to open and trigger the proximity sensor. The sensor must be secured in position to maintain an approximate 1/8 gap between the sensor face and the hinged door face. Discharge Plugged Sensor # POSITION & SECURE SO THAT THERE IS AN APPROXIMATE 1/8 GAP BETWEEN THE SENSOR FACE AND THE DOOR FACE. COIL UP EXTRA WIRE AND SECURE UNDER DRYER PLENUM 82

29 HMI Wiring Connections NOTE: See APPENDIX - HMI Wiring Connections for detailed schematic. Electrical Wire from Main Control to HMI Labels are provided - pull the following wires from the Main Control terminals to the HMI terminals strip. ATTENTION: The 120V power source needs to be connected to a customer supplied VA battery backup unit. WIRE LABEL E1A E2 E2A 24V OV WIRE COLOR BLUE BLUE BLUE BLUE WHITE Terminal block - inside HMI enclosure Ethernet Cable from Main Control to HMI Pull Cat 6 shielded ethernet cable from the Main Control to the HMI - maximum distance should be less than 300 feet. One end will plug into the PLC within the Main Control Box and the other end will plug into the Ethernet Switch within the HMI enclosure. PLC UNIT LOCATED IN MAIN CONTROL : PLUG ETHERNET IN HERE ETHERNET SWITCH IN HMI CABINET : PLUG ETHERNET IN HERE 83

30 Final Fuel Supply Hookup Liquid Propane (LP) WARNING NECO suggests hiring a professional to plan, setup, and connect your chosen fuel supply - Liquid Propane or Natural Gas. Either type MUST include an emergency shut-off valve. Plumbing assemblies for the liquid propane plumbing are preassembled in sections seperated by pipe unions as described below and shown in Figure 7K: 1. Regulator Leg - includes Regulator and Pressure Gauge 2. Vapor Line - includes 3/4 Schedule 80 elbow and pipes 3. Vaporizer 4. Liquid Line - includes 1/2 Schedule 80 elbow and pipes 5. Inlet - includes two 1/2 Solenoid Valves, Two Relief Valves, and Y Strainer # Support Bracket # Support Bar Vaporizer 3/4" Schedule 80 Pipe (Vapor Line) Regulator Leg Pressure Gauge Regulator Relief Valves 1/2" Sch 80 Pipe (Liquid Line) Inlet Solenoid Valves Y-Strainer Center sections have thru connection with union as shown. The top-most section will be an elbow. Table 7K - Installed Discharge Plugged Sensor in optional NECO housing 84

31 Refer to Figure 7L: The control loop, which includes the modulating valve / the primary & secondary solenoid valves / and the pilot solenoid valve, are already assembled on to the transition. Control Loop Figure 7L - Installed control loop on the transition Refer to Figure 7M: Attach the regulator at the union. The piping should be positioned between the transition and the platform. Regulator Leg Figure 7M - Attached Regulator Leg 85

32 Refer to Figure 7P: From inside the dryer run the 3/4 vapor line through the top pipe entry hole and connect the union to the regulator leg outside of the dryer. Top Pipe Entry Hole 3/4" Vapor Line Regulator Leg 3/4" Vapor Line OUTSIDE VIEW Connect at union INSIDE VIEW Figures 7P - Run 3/4 vapor leg through the top hole and connect at the union Refer to Figure 7Q: Position the # vaporizer tube support bracket so that the union lines up with the 3/4 vapor line. Using the bracket as a template, drill 5/16 [8mm] holes into the dryer section. Using 1/4 x 3/4 HB, FW, & WL, bolt the support bracket to the dryer section interior panel. Clamp the vaporizer to the bracket using the # support bar with 1/4 hardware. After the vaporizer is mounted, connect the 3/4 vapor line to the vaporizer with the union. Vaporizer /4" Vapor Line Figure 7Q - Mount vaporizer with bracket and connect 3/4 vapor line 86

33 Refer to Figure 7R: Push the 1/2 liquid line through the bottom hole and attach the vaporizer with the union. The liquid line should run through one of the platform supports. Bottom Pipe Entry Hole Vaporizer LIQUID LINE GOES THROUGH PLATFORM SUPPORT 1/2" Liquid Line VIEW - INSIDE DRYER Figure 7R - Connect 1/2 liquid line to vaporizer Refer to Figure 7S: Attach the Inlet to the 1/2 Liquid Line with the pipe union. Make sure the elbow or tee lines up with the pipe connection for the lower and upper pipe connections on the other dryer sections. 1/2" Liquid Line Inlet Figure 7S - Connect 1/2 liquid vapor line at union 87

34 Refer to Figure 7T: Connect between dryer sections using the 1/2 Schedule 80 pipe provided with the dryer section(s). NOTE: MIDDLE DRYER SECTIONS WOULD HAVE A T UPPER CONNECTION. THE TOP-MOST DRYER SECTION WOULD HAVE AN ELBOW. 1/2" Sch. 80 Pipe Figure 7T - LP connection between dryer sections Refer to Figure 7U: Connect the LP fuel source the the inlet elbow of the lowest dryer section. CONNECT LP FUEL SOURCE 88 Figure 7U - Connect LP Fuel Source

35 Natural Gas (NG) Refer to Figures 7V: Connect between dryer sections using the 2 Sch 40 pipe provided with the dryer section. Connect the NG fuel source to the inlet elbow of the lowest dryer section. 2" Sch. 40 Pipe CONNECT NG FUEL SOURCE NOTE: MIDDLE DRYER SECTIONS WOULD HAVE A T UPPER CONNECTION. THE TOP-MOST DRYER SECTION WOULD HAVE AN ELBOW. Figures 7V - NG connection between dryer sections & fuel source Natural connection Gas Inlet WARNING After the plumbing is connected, check all connections and pipes for leaks. Because pipe connections can loosen up due to vibrations encountered during shipping, it may be necessary to reseal the pipes. 89

36 Wet Bin Empty & Dry Bin Full Switches NOTE: These OPTIONAL switches are provided and installed by the customer. Refer to Figure 7W: The wet bin empty switch should be placed near the bottom of the wet holding bin. NOTE: The switch, when activated, only shuts off the filling equipment. The dryer will continue to dry grain until the dryer goes into a Low Dryer alarm status. The dry bin full switch should be placed near the top of the dry holding bin. NOTE: The switch, when activated, shuts down the metering rolls so that emptying the dryer stops. The dryer will automatically go into the shut-down processs. Once the switches have been positioned, route the wires to the main control box terminal strip and connect per the electrical schematic below: DRY BIN FULL WET BIN EMPTY Figure 7W - Connect wet bin empty & / or dry bin full sensor(s) 90

37 External Transport(s) Overview See APPENDIX - Wiring External Transports & Wiring NEMA Starters / IEC Starters / Air Systems for specific wiring information. Setup examples, as briefly shown here, are detailed with sample input data within the Commander Control Owner s & Operator s manual. NECO provides the ability to control two transport devices to FILL the dryer and two transport devices to EMPTY the dryer within the Commander Control system. All motor starters, starter coils, and overload contacts required are customer supplied. These external transport systems can control incoming (wet) grain and outgoing (dry) grain so that the overall system works in conjunction with the dryer. See Owner s & Operator s COMMANDER Manual for specifics to enter Fill / Empty Setup data. Examples of typical external transport systems that may be controlled within the automated Commander system -- EXAMPLE: Wet 1 Auger & Dry 1 Air System This example shows one wet system & one dry system to be controlled and operated by the Commander system. NOTE: Shown for example ONLY - individual configurations vary. 91

38 EXAMPLE: Wet 1 & Wet 2 Augers & Dry 1 Auger This example shows two wet systems & one dry system to be controlled and operated by the Commander system. NOTE: Shown for example ONLY - individual configurations vary. EXAMPLE: Wet 1 & Wet 2 Augers & Dry 1 & Dry 2 Augers This example shows two wet systems & one dry system to be controlled and operated by the Commander system. NOTE: Shown for example ONLY - individual configurations vary. 92

39 Commander Control Setup OVERVIEW NOTE: The setup of the Commander Control system is detailed within the Commander Control Owner s & Operator s manual. The dryer configuration information is input at the factory prior to system testing. This type of information includes: Language The dryer systems measurement units are either set to Imperial or Metric. Imperial units output temperature in Farenheight and volume in bushels. Metric units output temperature in Celcius and volume in cubic meters. The type of fuel supplied to the system. The dryer systems number of blowers & burners. Output gearmotor RPM The number of tiers each blower & burner supply. After installation, the Fill / Empty Setup and Timers Setup are completed by the customer. This type of information includes: If optional sensors are present, such as Wet Bin Empty or Dry Bin Full Presence of additional auxillary equipment, such as Unload Auger system, etc. Maximum grain output speed Various timers, such as amount of cooling time and metering roll stall time, etc. 93

40 8. APPENDIX Standard Model Specifications 94

41 Main Control Box Terminal Strip ATTENTION After installation is complete check the motor wires for the correct motor rotation & auger rotation direction. MODBUS COMMS 120 VAC 24 VDC WET BIN EMPTY SWITCH FILL SWITCH DRY BIN FULL SWITCH E-STOP WIRING AUX TRANSPORT OVERLOAD & RUN CONFIRMATION SIGNALS PLUGGED DISCHARGE SWITCH MOISTURE SENSORS LOW SWITCH SAMPLE SWITCH METERING ROLL STALL SWITCH AUXILLARY TRANSPORT RUN RELAY S 95

42 HMI Wiring Connections NOTE: The 120V power source needs to be connected to a customer supplied VA battery backup unit. The following schemetic indicates with dashed lines crossing INTO the HMI enclosure the connections to be made -- Electrical Wire from Main Control into thehmi Ethernet cable from Main Control into the HMI E-STOP 1PB XO OG JUMPER E-STOP 3PB XO XO OG JUMPER XO VDC V+ V- GND ETHERNET SWITCH N-TRON 105TX SPARE PORT FOR REMOTE ACCESS TO HMI ENCLOSURE PROGRAMMING PORT TO 309 TWIDO PLC FROM SEPERATE 120VAC, 1PH, 15A POWER SOURCE POWER OFF ON 1SS OX H N PC POWER SUPPLY MOXA MGATE MB3180 MODBUS ETHERNET SERIAL GATEWAY NULL MODEM COM2 RIBBON CABLE VDC OPTIONAL HEATER W/ THERMOSTAT PC BASED - MOISTURE CONTROLLER BAUD HMI ENCLOSURE (Indoors Installation Recommended) 96

43 Wiring External Transports The customer is responsible for wiring any external transport equipment. The following schematics are reference. 97

44 Wiring NEMA Starters / IEC Starters / Air Systems The customer is responsible for wiring any external transport equipment. The following schematics are reference. 98

45 Dryer Layout Configurations Each of the following graphic figures represent a standard dryer model: Each dryer model shows the sections as they are shipped - see towing section for additional information. Be sure to pay attention to the cord lengths of blower, etc. so that the longest cord will go to the secton FURTHEST from the control panel, and so on. For example only, a roof with level auger fill system (Safety Cage not shown) is shown above the top tier. See the OVERVIEW & ASSEMBLY section for details on the different fill systems. Dryer systems with only one blower use an angled transition and the ladder system is mounted at the rear of the dryer to the LEFT of plenum door. Dryer systems that have a roof (Level Auger or Gravity fill type) have a catwalk system. All ladder systems have a safety cage at the top. NOTE: This dryer model utilizes a rear mounted ladder system. Catwalk supports are shown for reference only & are located on the far side to line up with ladder system to the left of plenum door. TOP TIER 1 Dryer Model #D

46 NOTE: This dryer model utilizes a rear mounted ladder system. Catwalk supports are shown for reference only & are located on the far side to line up with ladder system to the left of plenum door. 4' TOP TIER 8' 1 14 GA. Dryer Model #D

47 NOTE: This dryer model utilizes a rear mounted ladder system. Catwalk supports are shown for reference only & are located on the far side to line up with ladder system to the left of plenum door. 4' TOP TIER 14 GA GA. Dryer Model #D

48 NOTE: This dryer model utilizes a rear mounted ladder system. Catwalk supports are shown for reference only & are located on the far side to line up with ladder system to the left of plenum door. 4' TOP TIER 8' 1 14 GA. Dryer Model #D

49 NOTE: This dryer model utilizes a rear mounted ladder system. Catwalk supports are shown for reference only & are located on the far side to line up with ladder system to the left of plenum door. 4' TOP TIER 14 GA GA. Dryer Model #D

50 NOTE: This dryer model utilizes a rear mounted ladder system. Catwalk supports are shown for reference only & are located on the far side to line up with ladder system to the left of plenum door. 8' TOP TIER 8' 14 GA. 14 GA. 1 Dryer Model #D

51 TOP TIER 8' 1 14 GA. 14 GA. 2 Dryer Model #D

52 TOP TIER 4' 14 GA. 14 GA. 1 8' 2 Dryer Model #D

53 Dryer Model #D16140 TOP TIER 8' 14 GA. 14 GA. 1 8' 2 107

54 TOP TIER 14 GA GA. 2 3 Dryer Model #D

55 TOP TIER 8' 14 GA. 14 GA. 8' 1 2 8' 3 Dryer Model #D

56 TOP TIER 4' 1 14 GA. 14 GA. 2 Dryer Model #D

57 TOP TIER 14 GA. 14 GA. 8' 1 2 Dryer Model #D

58 TOP TIER 4' 14 GA. 14 GA. 1 8' 2 Dryer Model #D

59 TOP TIER 8' 14 GA. 8' 1 14 GA. 2 3 Dryer Model #D

60 TOP TIER (18 GA) 14 GA GA. 2 3 Dryer Model #D

61 TOP TIER 4' 14 GA GA Dryer Model #D

62 TOP TIER 4' 8' Dryer Model #D

63 Top TOP TIER Dryer Model #D

64 TOP TIER 8' 14 GA. 8' 1 14 GA. 2 3 Dryer Model #D

65 TOP TIER 4' 14 GA GA Dryer Model #D

66 TOP TIER 4' 8' Dryer Model #D

67 Top TOP TIER Dryer Model #D FT, 24 TIER 121

68 122

Be sure to support the lower section using a crane or setting it on temporary blocks, etc..

Be sure to support the lower section using a crane or setting it on temporary blocks, etc.. 9. INSTALLATION Position Lower Dryer at Location Position the lower dryer section at the final location. Be sure to support the lower section using a crane or setting it on temporary blocks, etc.. Anchor

More information

Continuous-Flow Grain Dryer

Continuous-Flow Grain Dryer Continuous-Flow Grain Dryer Standard Controls Assembly / Installation Manual Effective Date: Oct 16, 2013 Publication Number: 7713393 Rev: B ***** HAVE QUESTIONS or NEED HELP?? ***** Before you call...

More information

Continuous-Flow Grain Dryer

Continuous-Flow Grain Dryer Continuous-Flow Grain Dryer Standard Controls Owner s & Operator s Manual Effective Date: Aug 1, 2013 Publication Number: 7713390 Rev: A Before you call... For effective communication to either your local

More information

Single-Module Portable Dryer

Single-Module Portable Dryer Single-Module Portable Dryer Models: 1100, 1200, 1200S CFAB-1 FAN, CFAB- 2 FAN, C2100A Installation Guide PNEG-1891 Version 3.1 Date: 09-09-16 PNEG-1891 All information, illustrations, photos, and specifications

More information

CLe-series Dishwashers

CLe-series Dishwashers CLe-series Dishwashers Blower-dryer electric (CLe SERIES) ML-138211 ML-138212 ML-138213 ML-138214 electric (CLeR SERIES) ML-138325 ML-138326 ML-138327 ML-138328 STEAM (CLe SERIES) ML-138226 ML-138227 ML-138228

More information

Home Stacked Washer/Dryer

Home Stacked Washer/Dryer Home Stacked Washer/Dryer Refer to Page 3 for Model Numbers Parts SWD443C_802107 www.comlaundry.com Part No. 802107R6 August 2014 Table of Contents Title Page Parts Ordering Information... 2 Serial Plate

More information

Home Stack Washer/Dryers

Home Stack Washer/Dryers Home Stack Washer/Dryers Refer to Page 3 for Model Numbers Parts SWD456C_806093 www.alliancelaundry.com Part No. 806093R1 December 2016 Table of Contents Title Page Parts Ordering Information... 2 Serial

More information

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330A755 CONTROL BOX KIT (12 VDC HEAT/COOL) 8530-750 CONTROL BOX KIT (24 VAC COOL ONLY)

More information

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN HSROG ML-111148 A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 43003 (June 2001) HOT SECTION 26 OVEN TOP SECTION

More information

Installation Manual. Breeder Control Installation Manual Patented U.S. Patent No. 7,980,129 and Patents Pending

Installation Manual. Breeder Control Installation Manual Patented U.S. Patent No. 7,980,129 and Patents Pending Breeder Control Installation Manual Patented U.S. Patent No. 7,980,129 and Patents Pending 11/25/2013 Table of Contents Installation Overview... 3 Components... 3 BinTrac Breeder Control... 3 Load Cell

More information

Continuous Flow Dryer Assembly Manual

Continuous Flow Dryer Assembly Manual Continuous Flow Dryer Assembly Manual Dryer Assembly Manual Sukup Manufacturing Company 1555-255th Street P.O. Box 677 Sheffield, Iowa 50475 Phone 641 892 4222 Fax 641 892 4629 Table of Contents Table

More information

Home Stack Washer/Dryers

Home Stack Washer/Dryers Home Stack Washer/Dryers Refer to Page 3 for Model Numbers Parts SWD456C_806093 www.alliancelaundry.com Part No. 806093R4 September 2018 Table of Contents Title Page Parts Ordering Information... 2 Serial

More information

Homestyle Stacked Washer/Dryer

Homestyle Stacked Washer/Dryer Homestyle Stacked Washer/Dryer Parts Refer to Page 3 for Model Numbers SWD443C_801802 www.alliancelaundry.com Part No. 801802R8 January 2018 Table of Contents Title Page Parts Ordering Information...

More information

TEMSPEC INC. VERTICAL FAN COIL UNIT MODELS TVA, TVE, TVS

TEMSPEC INC. VERTICAL FAN COIL UNIT MODELS TVA, TVE, TVS 6720 Columbus Road Mississauga, Ontario Canada, L5T 2G1 Tel: (905) 670 3595 Fax: (905) 670 3592 Web: www.temspec.com TEMSPEC INC. VERTICAL FAN COIL UNIT MODELS TVA, TVE, TVS INSTALLATION AND MAINTENANCE

More information

Homestyle Stacked Washer/ Dryer

Homestyle Stacked Washer/ Dryer Homestyle Stacked Washer/ Dryer Parts Refer to Page 3 for Model Numbers SWD441C_801998 www.alliancelaundry.com Part No. 801998R6 January 2018 Table of Contents Title Page Parts Ordering Information...

More information

Homestyle Stack Washer/Dryers

Homestyle Stack Washer/Dryers Homestyle Stack Washer/Dryers Refer to Page 3 for Model Numbers Parts SWD456C_806105 www.alliancelaundry.com Part No. 806105R1 November 2015 Table of Contents Title Page Parts Ordering Information...

More information

Installation Instructions

Installation Instructions Installation Instructions Outdoor Installation Kit Models AD250 & AW250 Part No. 24097 Qualifications for installation of the kit: You must be able to read and understand all instructions provided with

More information

Drying Tumblers Stacked 30 Pound Capacity

Drying Tumblers Stacked 30 Pound Capacity Drying Tumblers Stacked 30 Pound Capacity Models Through Serial No. DTCK9401011756 Refer to Page 3 for Model Numbers Parts www.alliancelaundry.com Part No. M411988R6 November 2012 Table of Contents Title

More information

2 PREPARE THE OPENING

2 PREPARE THE OPENING Installation Instructions 27 & 30 Electric Built-In Wall Ovens Questions? Call 1.800.GE.CARES (1.800.432.2737) or visit www.geappliances.com In Canada, call 1.800.561.3344 or visit www.geappliances.ca

More information

Revision B Printed Fall Elston Manufacturing HC Heater Owners Manual

Revision B Printed Fall Elston Manufacturing HC Heater Owners Manual Revision B Printed Fall 2007 Elston Manufacturing HC Heater Owners Manual Table of Contents Important Safety Information... ii 1) Description of Heater... 1 General information about your heater including

More information

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER OPERATING MANUAL MODEL AIR 500TM AIR DRYER Puregas, LLC 226-A Commerce St. Tel: 800-52-535 Broomfield, Colorado Fax: 303-657-2205 P/N P0255 REV A, 02/9/4 TABLE OF CONTENTS.0 GENERAL... 3 2.0 SPECIFICATIONS...

More information

Installation Manual PS-200 & PS-201

Installation Manual PS-200 & PS-201 Installation Manual PS-200 & PS-201 Table of Contents Pre-Uncrating Checklist... 1 Verifying System Requirements... 2 Verifying System Direction... 2 Verifying the Electrical Requirements... 2 Removal

More information

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS RV Products Division INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330C755 CONTROL BOX KIT (12 VDC HEAT READY) 8530-750 CONTROL BOX KIT

More information

Type 300 Series Bench Electrode Stabilization Ovens

Type 300 Series Bench Electrode Stabilization Ovens REPAIR PARTS INSTALLATION INSTRUCTIONS Type 300 Series Bench Electrode Stabilization Ovens *Please read all instructions, paying special attention to all cautions or warnings, before beginning any repairs.

More information

Service Manual Model 3163

Service Manual Model 3163 Service Manual Model 3163 Contents Important Safety Information.......... 1 Specifications.................. 2 General Information.............. 2 Direct Vent Requirements........... 2 Propane System................

More information

Installation Manual PS-225 & PS-275

Installation Manual PS-225 & PS-275 Installation Manual PS-225 & PS-275 Table of Contents Pre-Uncrating Checklist... 1 Verifying System Requirements... 2 Verifying System Direction... 2 Verifying the Electrical Requirements... 2 Removal

More information

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN

More information

WD7664 / WD7663 Maxon Burner Ellis Whisper Dryer Installation & Start UP

WD7664 / WD7663 Maxon Burner Ellis Whisper Dryer Installation & Start UP WD7664 / WD7663 Maxon Burner Ellis Whisper Dryer Installation & Start UP Receiving Do a quick visual inspection on the truck for any major damage prior to signing the paperwork. Damage should be noted

More information

Installation Instructions

Installation Instructions Installation Instructions For Free Standing NoFrost Combined Refrigerator-Freezers CS 1660 7082 653-00 PLEASE READ AND FOLLOW THESE INSTRUCTIONS These instructions contain Warning and Caution statements.

More information

WD7664 / WD7663 Maxon Burner. Ellis Whisper Dryer Installation & Start UP

WD7664 / WD7663 Maxon Burner. Ellis Whisper Dryer Installation & Start UP Title WD7664 / WD7663 Maxon Burner Ellis Whisper Dryer Procedure No. Installation & Start UP Procedure Author Chris Giordano Effective 1/23/17 Revision A Submitted By Chris Giordano Supersedes Date Revision

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS HPR SERIES PROOFER/RETARDER MODEL HPR1 ML-132406 30 In. (Standard) ML-132407 50 In. (Standard) ML-132408 63 In. (Standard) ML-132409 83 In. (Standard) ML-132410 96 In. (Standard)

More information

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) CONTROL BOX KIT (12 VDC HEAT/COOL)

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) CONTROL BOX KIT (12 VDC HEAT/COOL) INSTALLATION INSTRUCTIONS FOR 8330-5511 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) 9330-755 CONTROL BOX KIT (12 VDC HEAT/COOL) 7530B750 CONTROL BOX KIT (24 VAC COOL ONLY) 9530-755 CONTROL

More information

Installation Instructions Part No , Part No Part No

Installation Instructions Part No , Part No Part No Torsion-Flex Motor mount for PSC motors and Rigid-Mount for ECM motors Replacement Kit Cancels: New Installation Instructions Part No. 327752-401, Part No. 327753-401 Part No. 327754-401 IIK-310A-45-11

More information

Arctica Solar 1500 Series Heater Installation Manual

Arctica Solar 1500 Series Heater Installation Manual Arctica Solar 1500 Series Heater Installation Manual A wall mounted Arctica Solar 1500 series solar heater + PV panel demonstration wall The 1500 Series Solar Air Heater from Arctica Solar is designed

More information

LGB Gas fired boiler

LGB Gas fired boiler LGB Gas fired boiler Control Supplement LGB-5 Series 2 Propane gas CSD-1 Control System Part Number 550-110-682/0304 Please read this page first Hazard definitions To the installer... The following terms

More information

1.1. The unit shall be manufactured with quality, durability, and professionalism.

1.1. The unit shall be manufactured with quality, durability, and professionalism. 1. GENERAL SPECIFICATIONS 1.1. The unit shall be manufactured with quality, durability, and professionalism. 1.1.1. The unit shall be designed to be functional and look distinctive. 1.2. The unit will

More information

Vertical Stack Fan Coil Units Models: TVA, TVE, TVS

Vertical Stack Fan Coil Units Models: TVA, TVE, TVS 6720 Columbus Road Mississauga, Ontario Canada, L5T 2G1 Tel: (905) 670 3595 Fax: (905) 670 3592 www.temspec.com Vertical Stack Fan Coil Units Models: TVA, TVE, TVS INSTALLATION, OPERATION AND MAINTENANCE

More information

Installation Instructions

Installation Instructions Installation Instructions For Fully Integrated NoFrost Combined Refrigerator-Freezers HC 2060/2061 7082 485-00 Important PLEASE READ AND FOLLOW THESE INSTRUCTIONS These instructions contain Warning and

More information

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT RV Products Division INSTALLATION INSTRUCTIONS FOR 8330-5501 MOUNTING KIT 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330B755 CONTROL BOX KIT (12 VDC HEAT/COOL) 8530-750 CONTROL BOX KIT (24 VAC COOL ONLY)

More information

Installation Instructions

Installation Instructions Installation Instructions KFN 9855 ide en - CA Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations

More information

COMMERCIAL STACKED GAS DRYER/WASHER

COMMERCIAL STACKED GAS DRYER/WASHER COMMERCIAL STACKED GAS DRYER/WASHER MODEL NO. CGT8000XQ0 c 2012 WHIRLPOOL CORPORATION 5 12 Litho In U.S.A. (CMS) (bay) Part No. Rev. H CONTROL PANEL PARTS 2 CONTROL PANEL PARTS 1 Literature Parts W10335467

More information

OP44-1 REV 2: Removed depiction of air intake hole in the CB-907A Right Aft Case Baffle.

OP44-1 REV 2: Removed depiction of air intake hole in the CB-907A Right Aft Case Baffle. REVISION DESCRIPTION: OP44-1 REV 2: Removed depiction of air intake hole in the CB-907A Right Aft Case Baffle. OP44-4 REV 1: Steps rewritten to describe the air intake hole on the CB-907A Right Aft Case

More information

PolyMax H1-10 Dutch Bucket System

PolyMax H1-10 Dutch Bucket System 112529 PolyMax H1-10 Dutch Bucket System *Actual system may differ. PolyMax Dutch Buckets Versatile PolyMax Dutch Buckets are ideal for both small- and large-scale hydroponic growing. STK# DIMENSIONS 112529

More information

Installation Instructions

Installation Instructions Installation Instructions For Free Standing NoFrost Combined Refrigerator-Freezers CS 1660 7084 203-00 Important Please Read and Follow these Instructions These instructions contain Danger, Warning and

More information

Installation Instructions

Installation Instructions Installation Instructions For Fully Integrated NoFrost Combined Refrigerator-Freezers HC 2062 HCB 2062 HC/HCB 20 7082 373-00 Important PLEASE READ AND FOLLOW THESE INSTRUCTIONS These instructions contain

More information

CABINET PARTS For Model: KSSC42QTS02 (Stainless Steel)

CABINET PARTS For Model: KSSC42QTS02 (Stainless Steel) CABINET PARTS 42" BUILT IN REFRIGERATOR 10 11 Litho In U.S.A. (jdc)(psw) 1 Part No. Rev. A 1 Literature Parts W10161714 Use & Care Guide W10164072 Energy Guide W10159832 Service & Wiring Sheet 2306424

More information

TECHNICAL INFORMATION T 15xx Dryers

TECHNICAL INFORMATION T 15xx Dryers TECHNICAL INFORMATION T 15xx Dryers 2010 Miele USA Table of Contents 1.0 2.0 3.0 T 15xx Dryers Construction and Design... 5 1.1 Appliance Overview Vented Models... 5 1.2 Appliance Overview Condenser Models...

More information

Repair Parts List REFRIGERATOR MODEL NUMBER GC20B8C3EB. When requesting service or ordering parts, always provide the following information:

Repair Parts List REFRIGERATOR MODEL NUMBER GC20B8C3EB. When requesting service or ordering parts, always provide the following information: Repair Parts List REFRIGERATOR MODEL NUMBER GC20B8C3EB When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description

More information

Product Support Bulletin

Product Support Bulletin MODEL: SUBJECT: CONVENTIONAL, W/ C7 CAT ENGINE WEBASTO TSL-17 HEATER Body DATE: APRIL 13, 2004 INDEX: 6 PAGE: 1 OF 16 Before you start this procedure, perform Freightliner Service Bulletin #20-7 first.

More information

MASTERTEMP HEATER REPLACEMENT PARTS

MASTERTEMP HEATER REPLACEMENT PARTS 0 Section. Maintenance/Replacement Parts Electrical System (Key Nos. through 4), See Page 2 Burner System (Key Nos. through ), See Page 4 Water System (Key Nos. through ), see Page 2 Repair Parts are available

More information

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

B.C.S. Shop Heaters 26, 30 & 36 (36 shown) BIOMASS COMBUSTION SYSTEMS, INC. 67 MILLBROOK ST., SUITE 502 WORCESTER, MA 01606 508-798-5970 - FAX 508-798-5971 B.C.S. Shop Heaters 26, 30 & 36 (36 shown) INSTALLATION MANUAL HAND FIRED SYSTEMS 8-09 Biomass

More information

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY DESIGNED AND MANUFACTURED BY THE MAKERS OF COLEMAN -MACH AIR CONDITIONERS TABLE OF CONTENTS

More information

Field Start-Up Sheet Direct Fired Gas Equipment

Field Start-Up Sheet Direct Fired Gas Equipment Customer: Sales Representative: Model Number: Serial Number: Field Start-Up Sheet Direct Fired Gas Equipment ***Please Print*** INITIAL INSPECTION I. Installer Responsibilities 1. Remote Panel: All interconnecting

More information

Installation Instructions

Installation Instructions 30" Built-In Wall Oven JTP20, JTP25, JTP28, JTP48, JTPh0, JT912, JT915, JT952, JT955, ZET938, ZET958 If you have questions, call 1.800.GE.CARES www.geappliances.com or visit our website at: Before You

More information

INSTALLATION INSTRUCTIONS FOR 7330*5511 OR 7330*5512 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY)

INSTALLATION INSTRUCTIONS FOR 7330*5511 OR 7330*5512 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) INSTALLATION INSTRUCTIONS FOR 7330*5511 OR 7330*5512 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) 7530B750 CONTROL BOX KIT (24 VAC COOL ONLY) 8330A751 ZONE CONTROL KIT (12 VDC COOL ONLY) 8530B751

More information

ST. KITTS CEILING FAN

ST. KITTS CEILING FAN ITEM #0845047 ST. KITTS CEILING FAN MODEL #40829 Questions, problems or missing parts? Before returning this item to your retailer, call our customer service department at 1-800-643-0067, Monday - Thursday,

More information

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure) ASSEMBLY INSTRUCTIONS - NXS SERIES OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED RADIANT

More information

Dryer Master DM510 Installation Guide

Dryer Master DM510 Installation Guide INSTALLATION GUIDE Dryer Master DM510 Installation Guide Dryer Moisture Systems Inc. 115 Ardelt Avenue, Kitchener, Ontario Phone 519.725.4700 Fax 519.885.4300 USA and Canada Toll free at 1-888-318-0009

More information

Homestyle Stacked Washer/Dryer

Homestyle Stacked Washer/Dryer Homestyle Stacked Washer/Dryer Parts Refer to Page 3 for Model Numbers SWD452C_802847 www.comlaundry.com Part No. 802847R8 August 2012 Table of Contents Title Page Parts Ordering Information... 2 Nameplate

More information

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30) P. 1 of 12 JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30) Item: Qty: Description: 1 2 1 x 1 x 5/8 Tee Fitting 2 2 Plastic Snap-in Hose Grommet 3 4 1-1/2" Hose Clamps

More information

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY DESIGNED AND MANUFACTURED BY THE MAKERS

More information

Service Parts, Kits and Accessories

Service Parts, Kits and Accessories The parts identification guides on the following pages have been designed to give a quick reference to component parts used on pilot ignition agricultural building heaters. The guides identify components

More information

Pentz EF5 Installation Guide

Pentz EF5 Installation Guide Pentz EF5 Installation Guide Clear Vue Cyclones 145 Nix Road Liberty, SC 29657 888-299-0221 www.clearvuecyclones.com Disclaimers & Warnings WARNING: All persons, by purchasing a motorized dust collection

More information

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,

More information

Multiplexing Installation Instructions

Multiplexing Installation Instructions KOLD-DRAFT CLASSIC GB430/440/450 GB630/640/650 GB1220/1240/1250 Multiplexing Installation Instructions KOLD-DRAFT Ice Machine Products 1525 East Lake Road, Erie, PA 16511-1088 814/453-6761 FAX 814/455-6336

More information

CALDWELL DRYER INSTALLATION MANUAL. P/N Rev 0

CALDWELL DRYER INSTALLATION MANUAL. P/N Rev 0 CALDWELL DRYER INSTALLATION MANUAL P/N 095504 Rev 0 C H I E F I N D U S T R I E S, I N C. A G R I / I N D U S T R I A L D I V I S I O N Installation Manual WARNING: If the information in this manual is

More information

IT Module. User Manual. Document Revision Number 1 07/2013

IT Module. User Manual. Document Revision Number 1 07/2013 IT Module User Manual Document Revision Number 1 07/2013 Schneider Electric IT Module User Manual Table of Contents Table of Contents... 2 1. Safety Information... 3 2. Transportation and Installation...

More information

Graber Lake Forest Faux Wood and Premium Faux Wood Blind

Graber Lake Forest Faux Wood and Premium Faux Wood Blind 2 3 5 6 8 7 1 2" (5.1cm) Blind shown 1. Blind (cord tilt shown) 2. Mounting Brackets 3. Center support bracket (if required). Mounting screws (2 per bracket) 5. Projection brackets (optional, one per mounting

More information

DRI-AIR INDUSTRIES, INC. AHM & HPHM 2-4 HOPPER MOUNT DRYERS OPERATING MANUAL

DRI-AIR INDUSTRIES, INC. AHM & HPHM 2-4 HOPPER MOUNT DRYERS OPERATING MANUAL AHM & HPHM 24 HOPPER MOUNT DRYERS OPERATING MANUAL OPERATING MANUAL AHM/HPHM 24 HOPPER MOUNT DRYERS Page 1 DRIAIR INDUSTRIES, INC. 16 THOMPSON ROAD P.O. BOX 1020 EAST WINDSOR, CT 060881020 Tel. (860) 6275110

More information

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can

More information

fans & heaters SIMPLE, ROBUST AND RELIABLE

fans & heaters SIMPLE, ROBUST AND RELIABLE FANS & HEATERS fans & heaters SIMPLE, ROBUST AND RELIABLE For over 50 years, NECO has specialized in agricultural equipment engineering and manufacturing. NECO produces market leading grain dryers and

More information

Roll Heated Flatwork Finisher

Roll Heated Flatwork Finisher Roll Heated Flatwork Finisher 20 Inch (500 mm) Roll Heated Models Refer to Page 3 for Model Numbers Parts FWF1N_1300577 www.alliancelaundry.com Part No. 1300577R14 January 2018 Table of Contents Title

More information

Installation Instructions 30 French Door Built-in Wall Ovens

Installation Instructions 30 French Door Built-in Wall Ovens Installation Instructions 30 French Door Built-in Wall Ovens Questions? Call 1.800.GE.CARES (1.800.432.2737) or visit www.geappliances.com In Canada, call 1.800.561.3344 or visit www.geappliances.ca DESIGN

More information

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1976-360 (1-02) PP TABLE OF CONTENTS 1. Warnings......................................................

More information

INSTALLATION MANUAL FOR MODELS: TERAZZA, TRACCIO, MILANO, CERRATO

INSTALLATION MANUAL FOR MODELS: TERAZZA, TRACCIO, MILANO, CERRATO INSTALLATION MANUAL FOR MODELS: TERAZZA, TRACCIO, MILANO, CERRATO TABLE OF CONTENTS ROOM SPECIFICATIONS ELECTRICAL SPECIFICATIONS PLUMBING SPECIFICATIONS TECHNICAL SPECIFICATIONS INTRODUCTION ASSEMBLY

More information

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA 99336 www.jmcvr.com 1-509-586-9893 Table of Contents TABLE OF FIGURES...1 OVERVIEW OF THE HRC CAPABILITIES...2 INSTALLATION AND

More information

Page 1 of 6. Machine Serial No. Model Pump Size PRELIMINARY INSPECTION. Service and Connections

Page 1 of 6. Machine Serial No. Model Pump Size PRELIMINARY INSPECTION. Service and Connections STINGRAY Parts Washer: FIELD STARTUP FORM Page 1 of 6 Field Start-uor Company Authorized Individual. This completed form must be returned to initiate to be completed by StingRay Tech Services Field Service

More information

Installation Guide: PowerAire Quad

Installation Guide: PowerAire Quad INSTALLATION GUIDE FOR POWERAIRE QUAD QUAD-FAN ASSIST Tel (410)799-4200 1 of 14 INTRODUCTION Tate s Variable Speed Fan Assist device provides the user with unparalleled local control and reliability of

More information

TECHNICAL INFORMATION T1500 Series Clothes Dryers

TECHNICAL INFORMATION T1500 Series Clothes Dryers TECHNICAL INFORMATION T1500 Series Clothes Dryers 2003 Miele - Table of Contents 1.0 CONSTRUCTION & DESIGN 1.1 Appliance Overview - Vented 1 1.2 Appliance Overview Condenser Models 2 1.3 Controls Overview

More information

ICE/BEVERAGE DISPENSER

ICE/BEVERAGE DISPENSER Illustrated Parts List ICE/BEVERAGE DISPENSER Model: Enduro-2XX intellicarb Publication Number: 6209956IPL Revision Date: August 3, 200 Release Date: March 26, 204 Revision: B Visit the Cornelius web site

More information

General Characteristics.3. S.M.A.R.T System Set-up...5. Start-up Procedures.6. Shut-down Procedures 8. General Maintenance..8

General Characteristics.3. S.M.A.R.T System Set-up...5. Start-up Procedures.6. Shut-down Procedures 8. General Maintenance..8 1-800-661-3842 1 TABLE OF CONTENTS General Characteristics.3 How the S.M.A.R.T System Works..3 S.M.A.R.T Technical Specifications..3 Erecting the S.M.A.R.T System..4 S.M.A.R.T System Set-up...5 Start-up

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS The SensorNet I/O Module provides attachment for up to 32 alarms and up to 16 switched devices. An RS-232 or RS-422 communications port is also provided for receiving serial alarms.

More information

SAFETY AND INSTALLATION MANUAL MODEL 8100

SAFETY AND INSTALLATION MANUAL MODEL 8100 SAFETY AND INSTALLATION MANUAL ENERGY RECOVERY VENTILATORS MODEL 8100 Provides year-round fresh air Recovers 77% of the apparent heating or cooling energy from the exhausted air See Warnings Page 3 Table

More information

STEAMPRO. Steam Generator Troubleshooting and Service Guide

STEAMPRO. Steam Generator Troubleshooting and Service Guide STEAMPRO Steam Generator Troubleshooting and Service Guide TABLE OF CONTENTS Page PREFACE... 1 I. STEAMPRO STEAM GENERATOR SYSTEM...2 II. PLUMBING AND ELECTRICAL...3-4 III. SYSTEM OVERVIEW... 5-10 IV.

More information

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS SUPPLEMENT VENTING INSTRUCTIONS FOR INSTALLATION AND OPERATION INSTRUCTION MANUALS FOR THE FOLLOWING PRODUCT TYPES: HIGH EFFICIENCY CONDENSING COMMERCIAL, COMMERCIAL POWER DIRECT VENT, LIGHT DUTY COMMERCIAL

More information

V SERIES HDR GAS RANGES

V SERIES HDR GAS RANGES SERVICE MANUAL ONE POWERFUL PACKAGE V SERIES HDR GAS RANGES TOPS Open Top Hot Top Griddle Top Work Surface BASES Standard Oven Convection Oven Cabinet Base - NOTICE - This manual is prepared for use by

More information

Water Distiller Service Manual

Water Distiller Service Manual Water Distiller Service Manual Water Distiller Service Manual L70478WT 2008 Regal Ware, Inc. Table of Contents RECOMMENDED TOOLS... 2 GENERAL INSPECTION...3 BOILING CHAMBER TROUBLESHOOTING & REPAIRS Description...

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

ALG181J6 TAMBOR (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P)

ALG181J6 TAMBOR (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) ALG181J6 TAMBOR ALG181J6 TAMBOR 1 131084710 PANEL LELF SIDE WHITE (S/P) 1 131084701 PANEL LELF SIDE ALMOND (S/P) 2 131168200 SCREW (S/P) 3 131883301 PANEL (S/P) 4 134799902 PANEL REAR (S/P) 5 5303281019

More information

Global-Tek (Singapore) Pte Ltd

Global-Tek (Singapore) Pte Ltd Global-Tek (Singapore) Pte Ltd Door Type G-TEK G-TEK WWW.GLOBAL-TEK.COM.SG 1 P a g e Door Type, CONTENTS Wash and Rinse Arm Assembly....... 3-4 Booster Heater... 5-6 Wash Chamber.. 7-8 Door Lift Assembly...9-10

More information

KIT NOTICE. These instructions are for replacing the three existing thermostats with a single new solid-state thermostat.

KIT NOTICE. These instructions are for replacing the three existing thermostats with a single new solid-state thermostat. KIT 06401-004-22-16 5 1 2 NOTICE 3 (3 PLC'S) These instructions are for replacing the three existing thermostats with a single new solid-state thermostat. 4 PREPARATION PARTS INCLUDED 6 1 7 5 8 2 4 (4

More information

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL EFFECTIVE JULY 31, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution

More information

30" ELECTRIC SLIDE-IN RANGE INSTALLATION INSTRUCTIONS

30 ELECTRIC SLIDE-IN RANGE INSTALLATION INSTRUCTIONS United States INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. FOR YOUR

More information

INSTALLATION INSTRUCTIONS FOR SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP

INSTALLATION INSTRUCTIONS FOR SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP RV Products Division INSTALLATION INSTRUCTIONS FOR 46515 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP TABLE OF CONTENTS 1. Warnings.................................................. 2 2. Component

More information

CME1856W Service Parts

CME1856W Service Parts This parts list contains the part numbers and description of the replacement parts available for this model. To avoid costly and time consuming errors, double check the model and voltage before ordering

More information

In-Wall Slide-out OEM INSTALLATION MANUAL. In-Wall Slide-out OEM Installation Manual

In-Wall Slide-out OEM INSTALLATION MANUAL. In-Wall Slide-out OEM Installation Manual In-Wall Slide-out OEM INSTALLATION MANUAL Rev: 01.22.2018 In-Wall Slide-out OEM Installation Manual TABLE OF CONTENTS Safety and System Information 2 In-Wall Slide-Out Chassis Specification 3 6.1.1 Slide-Out

More information

HydroCycle Vertical Aeroponic Systems

HydroCycle Vertical Aeroponic Systems HydroCycle Vertical Aeroponic Systems 2018 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. *Actual system may differ from system shown. 113593 8' Vertical System (44

More information

DEMA 830 Laundry Master TM Installation Instructions

DEMA 830 Laundry Master TM Installation Instructions I-656 Pg. 1 of 9 SYSTEM OVERVIEW The DEMA 830 Laundry Master is designed for long reliable use with simplicity in mind for both the installer and user. The system is based on the reliable DEMA peristaltic

More information

F-Series Tower Drying

F-Series Tower Drying Tower Dryers F-Series Tower Drying F-Series Tower Drying We define grain drying. We define grain drying. FFI Features Gravity inlet does not require leveling auger, reducing the number of moving parts.

More information

Repair Parts List DRYER MODEL NUMBER MDG32PC3AW. When requesting service or ordering parts, always provide the following information:

Repair Parts List DRYER MODEL NUMBER MDG32PC3AW. When requesting service or ordering parts, always provide the following information: Repair Parts List DRYER MODEL NUMBER MDG32PC3AW When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description 2005

More information