MANUAL FOR AIR COOLED INDUSTRIAL CHILLERS MODEL: UCS-10A

Size: px
Start display at page:

Download "MANUAL FOR AIR COOLED INDUSTRIAL CHILLERS MODEL: UCS-10A"

Transcription

1 MANUAL FOR AIR COOLED INDUSTRIAL CHILLERS MODEL: UCS-10A

2 Universal Chilling Systems, LLC. 2 Unit Manual Contents 1. Specification 2. Transportation 3. Unit Installation 4. Electrical Installation 5. Commissioning 6. Troubleshooting Operation Manual Contents 1. Appearance of DM500B 2. Face of pages 3. User's inquiry operation 4. User's set 5. Unit Operation 6. Trouble disposal 7. Settings 8. Diagram of electrical connection

3 Universal Chilling Systems, LLC Product Description The UCS series Products are chillers that can produce cooling medium of temperature around 7º C or - 5º C, and lower on requirement of our customers. The chillers are applicable to the industries of textile, chemicals, machinery, electronics, medicine and health, food etc. Main components World famous brand refrigeration parts are employed for all products; World leading brand compressors High efficient heat exchangers of shell & pipe or copper & fin type Digital control system Multi-Protection devices for over loading, high and low pressure, phase lacking and water lacking etc.

4 Universal Chilling Systems, LLC Specifications Cooling Condition MODEL Chilled Water Inlet Temp. Chilled Water Outlet Temp. Ambient Temp. UCS-10A 12º C 7º C 35º C Nominal Cooling Capacity Power Supply KW 30 x 10³kcal/Hr P-440V-60Hz Type/QTY Fully Closed Scroll/1 piece Compressor Cooling Input Power(KW) Cooling Operation Current(A) Evaporator Chilled Water Flow(m³/h) 5.16 Interface Size DN40 Quantity 2 Condenser Fan Power/KW 0.64 Operation Current(A) 0.99 Safety Protection Device High &low voltage protection, current overload protection, antifreezing protection, electronical delay protection Power (KW) 1.1 Water Pump Current (A) 2.42 Head(M) 30 Water Tank Material 304SS Volume(L) 140 Length (mm) 1810 Overall Size Width (mm) 975 Height (mm) 1730 Weight /KG 435 Overall Unit Power/KW Current(A) 19.5 Refrigerant Type R407C Notice: 1) Normal conditions: Chilled water inlet temperature 12º C, outlet temperature 7ºC, ambient temperature 35ºC 2) Standard power supply: 3P-440V-60Hz, proposed three-phase four-system, allowing voltage fluctuation -25~10%, frequency fluctuation ± 2%. 3) Host for the actual lift is pump lift host internal head loss minus. (1mH20=9.8kPa)

5 Universal Chilling Systems, LLC Transportation Only the bottom support is allowed to support the unit, and fort vehicle or crane vehicle is required to move the unit. The unit must be kept vertical in the transportation; the chains cannot touch the side heat exchanger, top, and side plates. 3. Installation 3.1. Positioning The unit must be installed where the air flow is good, in door sheltered from raining. The space on the top must be larger than 2 meters, which is good enough to bring the hot air to environment. The space at the air inlet side of the unit must be larger than 1.5 meters that is necessary to normal operation of it. A strong, water level concrete base, with height over 20 cm is needed. The repair and maintenance space for man is to be left. The environment of the unit is -15~50 C, relative humidity 80%.

6 Universal Chilling Systems, LLC Air Duct An air duct is needed for the place where the air flow is not guaranteed. As shown below in the diagram Pipeline Installation The unit has been tested and inspected before delivery. What the users need to do is to just fix on its chosen position, connect to chilled water system, and power supply following the instructions. The water flow protection switch is necessary in the chilled water system to prevent accident of evaporator freezing broken in case there is no water or too less water in the pipe. It is recommended to fix the water flow switch outside the unit box. 4. Electrical Installation 4.1 The UCS Chillers have temperature controller and electrical control box in the unit, the work of electrical installation is only to connect the unit to power supply. 4.2 In case other control is needed, it must be done observing the local electrical standard and rules to guarantee the safety and stable operation. 4.3 Wire Selection It is recommended to select the wire thickness based on multiple the total current of the chiller and other auxiliary facility as pumps etc. 4.4 Power Supply Requirement Voltage: Rated V -25~10%; Frequency: Rated Hz±2%; In case the Voltage is over the limit, it is not allowed to start the unit.

7 Universal Chilling Systems, LLC Commissioning 5.1. Check before Start Operation A. Check the environment that everything is normal. B. Check the power supply connection and the power supply to be sure the phase voltage conforms to the requirement. C. Check the water valves on the chiller water pipelines to be sure it is opened. Check the pumps are normal after pressure test, dirt discharge, air discharge and trial operation. D. Check the water level in the water vessel, the connection of the water supplementary inlet to the vessel, overflowing outlet is connected to the sewer Operation of Chilled Water System A. The chilled water need to be processed, to keep the PH value between The higher alkalinity may accelerate the corrosion of the copper pipes, decrease the use time of the heat exchangers. B. After the unit and auxiliary facility are fixed, the water lines need to be processed for pipe cleaning, pressure test, air discharge, trial running of chilled water system etc. The unit commissioning and trial running can be started after confirmation of all is normal. C. Operation of the unit a. Over 12 hours of power supply on to the unit is needed before the unit start. b. Start order for the air cooled unit: chilled water pumps unit; c. Stop order for the air cooled unit: unit chilled water pumps; D. After start, judge the operation status by observing the high and low pressure gauges. The normal range of the high pressure is 8-16kg/cm2, the low pressure range is 1.5-4kg/cm2 a. For the air cooled unit, observe the rotation direction of the fans, if it runs in wrong direction, change the power supply wire connection to correct it before start. b. The set value of all protection devices must not be changed, they have been set at correct value before delivery. c. In case the error alarm is on and the unit is stopped, first press the stop button, the alarm will go off, and then check the trouble reason. Do not start forcibly before the trouble is eliminated. d. Do not stop the unit by cut off the main power supply unless in emergency case. If the unit needs to be stop for long time in winter, stop the unit first, then cut off the main power supply, and drain the water in the system. e. To guarantee the normal and stable operation of the unit, keep clean, tidy, and air flow in the machine rooms; clean the condensers periodically Maintenance A. Keep the clean of the condensers, clean it periodically and good air flow condition. B. Clean the condensers after a period of operation, especially for the dirty environment and the H/L differential pressure acts and refrigeration capacity deceased.

8 Universal Chilling Systems, LLC Troubleshooting Troubles Causes Solutions Cannot start High pressure too high Low pressure too low Frosty of suction line and/or compressor 1. Power supply is not available or voltage too low 2. Wrong Temperature set, the contactor is always off 3. Over load protection not recovered after cut off 1. Clear the electrical trouble, and provide the power supply on requirement 2. Make correct temperature set 3. Press the recovery button 1. Too dirty of the condensers 1. Clean the condensers 2. Too much refrigerant filled 2. Discharge some refrigerant 3. The expansion valve opens too small 3. Adjust the opening of the valve 1. Too little of the refrigerant. 1. Leakage check, increase refrigerant and adjust the valve 2. Blockage of the filter. 2. Clean or change the filter 3. The expansion valve opens too small 3. Adjust the opening of the valve 1. The expansion valve opens too large 1. Adjust the opening of the valve 2. Too much refrigerant filled 2. Discharge some refrigerant 3. Load too small 3. Increase the load

9 Universal Chilling Systems, LLC. 9 Operation Manual of Electrical Control of UCS Series Industrial Chillers 1. Appearance of DM500B 2. Face of pages 3. User's inquiry operation 4. User's set 5. Unit Operation 6. Trouble disposal 7. Settings 8. Diagram of electrical connection Contents

10 Universal Chilling Systems, LLC Appearance of DM500B The panel as fig 3-1, with 12 keys, 6 of them is lighted; the panel dimension is 196mm x 115.5mm W 2. Face of Pages 2.1. Start Display WELCOME TO OUR CONTROLLER 9 Air-Water Cool 500ATYF02V1002 First page shows "welcome" count down is shown at the right bottom in reverse color. The second page, first line shows model and mode, second line shows version number of the program at the left, and count down is shown at the right bottom in reverse color Main Face After the count down if finished, the user's main face is shown as below: TIN: l0 C T.OUT 5 C SET: 5 C STOP Means turn up, means turn down.

11 Universal Chilling Systems, LLC. 11 If the sensor of T.out or T.in shows no temp, the show will be C, ERR shows ºC a. Welcome show WELCOME TO OUR CONTROLLER b. Model show (Water cooled chiller), mode (cool only, Heat pump, E heating), run mode (cool, heat, fan, water, defrost) and start type (manual, timing). Air Water. M. H.PUMP COOL c. Face show: show main temp (T.in, T.out), set temp and running status (run, time delay, stop). The reverse color shows the control temp for energy adjustment (T.in as control temp as fig below). T.IN means temperature of returning water or air; T.OUT means temperature of out water or air 3. User s Inquiry Operation Press ENQIRE, shows as below: TROUBLE LIST TROUBLE HIS. This system includes inquiring content as below: TROUBLE LIST TROUBLE HIS. RUN TIME CHECK CLOCK CHECK Select by or, enter each page by OK, by RETURN come back to main face.

12 Universal Chilling Systems, LLC. 12 1) TROUBLE LIST In inquire page, select TROUBLE LIST by and, press OK to enter TROUBLE LIST show. INQUIRE COMMU.ERR The second line shows trouble. Press RETURN to up level menu. 2) TROUBLE HIS. In inquire page, select TROUBLE HIST. by and, press OK to enter TROUBLE HIST show. 1: INVERSE PHASE 2: CM1 ERR The max number of historical trouble is 8, with the present trouble placed in front lines. Press RESET for 3 S to remove the historical trouble. 3) RUN TIME CHECK In inquire page, select RUN TIME CHECK by and, press OK to enter RUN TIME CHECK show. COM1: 0 H 0 H COM2: 0 H 0 H The accumulated run time will be showed according to the compressor number. 4) CLOCK CHECK In inquire page, select CLOCK CHECK by and, press OK to enter CLOCK CHECK show. 2009/01/04 13:14:40 WED. The time show here is the real time, the start and stop time will act according to this time. Press SET to enter time set state for hour, minute setting.

13 Universal Chilling Systems, LLC User s Set In user s main face, press SET entering user s set face, the show as below: SET T.OUT: SET Mode: 5º C COOLING The set face includes: Set T. OUT: 5 C (shows T. OUT set when the T. OUT is to be controlled.) Set mode: cool On/Off: M. (M/week timing/timing once) TIMING SET Use set Only 2 will be shown, other contents can be inquired by and. Select one of the 4 items, change it by <+>, <->, the change will go into effect immediately. The change will be kept after power off. It will return to main face in this face more than 30 S without touch. After the change, press RETURN to come back to main face. M/week timing/time once: M means the automatic on and off is stopped; week time means to start or stop on set time on the set week day. Time once means to start or stop on set time each day in the set period. If the clock is set as 0, it means no timing in the period. If the timing once is selected, when the set date is expired, press SET, the present date will set automatically. When select the week timing and timing once at the same time, the priority will be to the timing once. i) The TIMING SET In the user's page, select TIMING SET by and, press OK to enter TIMING SET. a) If the ON/OFF is set to M, the TIMING SET will not be available. b) If the ON/OFF is set to WEEK TIMING, it shows below: WEEK TIMING SET DATE TIMING SET c) If the Timing is set to timing once, it shows below: DATE TIMING SET CLOCK TIMING SET In the B face, select WEEK TIMING by and, to set WEEK TIMING, press OK, then show will below: SUN. > MON.

14 Universal Chilling Systems, LLC. 14 Select weekday by and, press OK to change the state. If there is > before the weekday, it means on the weekday the automatic ON/OFF will act, if no >, the ON/OFF will not be acted automatically. In C face, select DATE TIMING by and, press OK to enter DATE TIMING, the show is below: DATE: 2005 / 01 / / 01 / 01 Select the item to be changed by and, press <+>, <-> to change the item. In b or c face, select SET CLOCK by and, press OK to enter time set page as below: ON: OFF: 07h 59 m 22h 30 m Select the item to be changed by and, press <+>,<-> to change the item. The data will be kept in memory after the power is off. After the change, press RETURN to come back to menu of up level. ii) USE SET In user's page, select USE SET by and, it will show as below: COMP.1: NONE COMP.2: USE The show depends on the number of compressor and heater in RUN SETTINGS SYS. SETTINGS and mode of OUTPUMP. The energy adjustment and trouble check will not be available in case the compressor or heater is set at NONE. Select the item to be changed by and, press <+>,<-> to change the item. The data will be kept in memory after the power is off. After the change, press RETURN to come back to menu of up level.

15 Universal Chilling Systems, LLC Settings Default password of repairman's: 1 2 3, that is the key: START, INQUIRE, SET. When system is in STOP page in the user's main face, press and <+> at the same time, it will enter SYS. SETTINGS page as below. INPUT PASSWORD **** Then input the password, press OK. If is the wrong password, the show will be below: ERROR! TRY AGAIN Press RETURN to come back to main face. The password is two levels, after password of manufacturer s or repairman s is put in, it will enter RUN SETTINGS menu as below: 1: RUN SETTINGS 2: MODIFY PWD When enter by the repairman's password, there will be 2 items in front of the menu. 1: RUN SETIINGS 2: MODIFY PWD. I. RUN SETTINGS In RUN SETTINGS, select RUN SETTINGS by and, press OK to enter RUN SETTINGS show below: 1: SYS. SETTINGS 2: SETTINGS 1 There are 10 items for RUN SETIINGS, and there are sub-items under each item. The 10 items are below: 1. SYS. SETTINGS (Manufacturer's password can set all; repairman's password can change only the items of POINT and SWITCH) 2. TIME SETTINGS 1 3. TIME SETTINGS 2

16 Universal Chilling Systems, LLC TEMP. SETTINGS 1 5. TEMP. SETTINGS 2 6. TEMP. SETTINGS 3 7. TEMP REVISE 8. INPUT SET 1 9. INPUT SET SENSOR SET II. MODIFY PWD Select MODIFY PWD by and, press OK to enter MODIFY PWD as below: All keys on the panel can be taken for password except OK and RETURN. A. When enter by the manufacturer's password, only the manufacturer 's password can be modified, show is below. First new password show: INPUT5-6BIT PWD ****** The manufacturer's password must be 5-6 Bit; after the new password is in, the show is below: PASSWORD CHECK! ****** If the password is the same for both times, the show is below: PASSWORD ACCEPT PRESS ANY KEY! If the check password is not the same as the new password, return to new password (manufacturer's page). B. When enter by the repairman's password, only the repairman's password can be modified, show is below: First new password show: INPUT1-4BIT PWD ****

17 Universal Chilling Systems, LLC. 17 The repairman s password must be 1-4 Bit; after the new password is in, the show is below: PASSWORD CHECK! ****** If the password is the same for both times, the show is below: PASSWORD ACCEPT PRESS ANY KEY! If the check password is not the same as the new password, return to new password (repairman s page). 6. Unit Operation 6.1. Start Press the START to start the unit: start the pump time delay start the cooling fan time delay start the compressor. All the delay time can be changed Stop Press the STOP to stop the unit. Stop the running compressor time delay stop the cooling fan time delay stop the pump. The delayed time can be changed. In the delaying period, the user's page show: time delay, after the delay, the show is stop Trouble and Cause i) Compressor breakdown: the cause may be compressor overload, overheat, too high or low ii) pressure. Unit breakdown: Pump overload, water lack, error of sensors of in and out water, error of power etc Run Indication The run indicator will close after all system is running; it will open after all equipment stop Alarm The alarm will be on if some system is out of order; if all trouble is disposed, the alarm will be off.

18 Universal Chilling Systems, LLC Trouble Disposal When trouble occurs, the alarm will work and the reset indicator flickers. Press the sound erasing key, the alarm sound will stop; the reset indicator flickers continue. After the trouble is disposed, press RESET and the trouble record is erased. When all trouble is reset, the reset indicator will go off. RESET is available in all pages of user's face. When the system occurs trouble from the no trouble state, it will enter error inquire automatically. After it enters the AUTOMATI C INQUIRE, it will not return even if no key is pressed 8. Settings Settings may vary with different types of unit. Main menu Sub menu Content AIR-WATER 1: SYS. SETTINGS SYS. AIR-WATER,W-W SYS.WATER-AIR, AIR-AIR AIR-WATER MODE COOL, HEATER, H.PUMP COOL OUTPUMP NONE, CIRCLE, RECYCLE NONE COMP.NUM Max 4 - Min 1 2 ELEC.H.NUM Max 3 - Min 1 0 POINT T.IN, T.OUT T.OUT SWITCH SW.1, SW.2 SW.1 Co. None None 2:TIME SETTINGS 1 PROTECT Max 255S; Min OS ; 180S CYCLE Max 255S; Min OS; 120S COOLER_D Max 255S; Min OS ; 15S CHILLER_D Max 255S; Min OS; 30S ERR.DELAY Max 99S; Min OS; 2S SCR.SAVER Max 255M; Min OM; 30M 4:TEMP SETTINGS 1 ADD DIF Max 25º C Min 1º C 2 SUB DIF Max 25º C Min 1º C 2 LOWER_L Max 35º C Min -20º C -10 LOW T Max 20º C Min -20º C -7 LOWT.RE Max 25º C Min -20º C -5 7: TEMP REVISE IN Max 9º C Min -9º C 0 OUT Max 9º C Min -9º C 0 8: INPUT SET 1 CM HP Normally closed, Normally open Normally closed CM LP Normally closed, Normally open Normally closed CM ERR Normally closed, Normally open Normally open PW ERR Normally closed, Normally open Normally open

19 Universal Chilling Systems, LLC. 19 9: INPUT SET 2 PUMP LACK Normally closed, Normally open Normally closed FAN OVERL. Normally closed, Normally open Normally open FAN OVERH. Normally closed, Normally open Normally open P_SWITCH Normally closed, Normally open Normally closed 10: SENSOR SET IN Use, No Use Use OUT Use, No Use Use

20 Universal Chilling Systems, LLC. 20

MODULAR CHILLER. R410a R22

MODULAR CHILLER. R410a R22 Ra R 3 Ra/-0 R/-0 New ppearance New Y-shape design, more fashion IR-COOLED SERIES (Ra) Compressor ir cooling side heat exchanger Best scroll compressor, low sound power level, By using calculation model

More information

AIR SOURCE HEAT PUMP WATER HEATER

AIR SOURCE HEAT PUMP WATER HEATER AIR SOURCE HEAT PUMP WATER HEATER Installation & Instruction Manual Model: SWBC-3.H-B SWBC-9.H-B-S SWBC-4.0H-A-S SWBC-4.0H-B-S Contents CONTENTS Ⅰ.To our customers(before installation) -------------------------------------------------

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA OWNER S MANUAL Vintage Classic HEAT COOL models Proudly Made in the USA support@aquacomfort.com www.aquacomfort.com/service-and-support 888-475-7443 Manufacturing High Quality, High Efficiency Heat Pump

More information

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB Summary 1 CONNECTIONS... 8 1.1 TEMPERATURE PROBES...8 1.2 PRESSURE PROBES...9 1.3 LOW VOLTAGE DIGITAL INPUTS...10 1.4 LIVE DIGITAL INPUTS...11 1.5 RELAY OUTPUTS...12 2 VOLTAGE/FREQUENCY INPUT...13 3 POWER

More information

MODELS LIST. Nominal Capacity RT

MODELS LIST. Nominal Capacity RT 1. MODELS LIST. NOMENCLATURE 3. FEATURES 4. PRODUCT DATA 5. PERFORMANCE CORRECTION 6. ANTIFREEZE 7. INSTALLATION 8. ELECTRICAL DATA 9. SCHEMATIC WIRING DIAGRAM 10.MICROPROCESSOR CONTROLLER 11.APPLICATION

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS COMFORT CONTROL CENTER 2 THERMOSTAT OPERATING INSTRUCTIONS PROGRAMMABLE THERMOSTAT MODEL 3314080.000 BLACK 3314080.015 WHITE USA SERVICE OFFICE Dometic Corporation 1120 North Main Street Elkhart, IN 46514

More information

Wired controller KJR-08B/BE. Run. Fault. TB Tot. Out. Query. Heat. Net-On. Turn-On Mode

Wired controller KJR-08B/BE. Run. Fault. TB Tot. Out. Query. Heat. Net-On. Turn-On Mode R0A (kw-0kw) 0Hz KJR-0B/BE is a human-machine interaction(hmi) used for the communication between chiller operator and main board on the chiller itself. The setting and operation order can be send to the

More information

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with

More information

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB Summary 1 CONNECTIONS... 3 1.1 TEMPERATURE PROBES...3 1.2 LOW VOLTAGE DIGITAL INPUTS...3 1.3 LIVE DIGITAL INPUTS...4 1.4 RELAY OUTPUTS...5 2 POWER SUPPLY... 6 3 SERIAL CONNECTIONS... 6 4 SOFTWARE... 7

More information

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL 1. INTROUCTION Zone control is a two pieces fan coil thermostat available for Heat/Cool versions. Its application is for the duct type system

More information

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA. OWNER S MANUAL Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750 Proudly Made in the USA support@aquacomfort.com 888-475-7443 Manufacturing High Quality, High Efficiency Heat

More information

User manual for reversible heat pump

User manual for reversible heat pump User manual for reversible heat pump Heat pump system integrated in Geniox, DV or TIME air handling unit Manual version 1.01.14 Part number of this manual 90925374 Contents DECLARATION OF CONFORMITY EXAMPLE...2

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

Precise Temperature Control; Compact Footprint

Precise Temperature Control; Compact Footprint Precise Temperature Control; Compact Footprint The Conair EP1 Series Portable Chillers are designed for 1 to 3 ton applications. Available as air-cooled or water-cooled, with pump sizes from 1/4 to 3 Hp

More information

SERVICE MANUAL UNI SPLIT SERIES. ASC-xxBI, ASD-xxBI, ASF-xxBI, ASGE-xxBI, ASGE-xxBI-3

SERVICE MANUAL UNI SPLIT SERIES. ASC-xxBI, ASD-xxBI, ASF-xxBI, ASGE-xxBI, ASGE-xxBI-3 EN SERVICE MANUAL UNI SPLIT SERIES ASC-xxBI, ASD-xxBI, ASF-xxBI, ASGE-xxBI, ASGE-xxBI-3 Original instructions IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE. THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE. Central Chillers & Pump Tanks C E N T R A L C H I L L E R S 30RAP Series Central Chillers 10-60 Tons 30RAP Series air-cooled central

More information

Installation, operating and maintenance ECOLEAN - EAC/EAR

Installation, operating and maintenance ECOLEAN - EAC/EAR Installation, operating and maintenance ECOLEAN - / Providing indoor climate comfort Revision 3 MIL103E-0909 12-2009 TABLE OF CONTENTS Page PREFACE 2 DATA PAGE FOR UNIT COMMISSIONING 3 1. 2. 3. 4. General

More information

Product Features Technical Training 2007

Product Features Technical Training 2007 Product Features Product Features Less foot print occupied Less space required. Product Features Made of AISI 316 Stainless Steel High heat exchange efficiency Product Features New Technology BPHE True

More information

AIR-HANDLING UNIT (AHU) DESIGN GUIDELINE

AIR-HANDLING UNIT (AHU) DESIGN GUIDELINE INTERFACE AIR-HANDLING UNIT (AHU) DESIGN GUIDELINE September 2018 [Model Name] PAC-IF013B-E PAC-SIF013B-E Related document: Refer to the following manual PAC-IF013B-E/PAC-SIF013B-E INSTALLATION MANUAL

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating

More information

Trouble Shooting Guide FAA, 3-phase (D3631)

Trouble Shooting Guide FAA, 3-phase (D3631) Trouble Shooting Guide FAA, 3-phase (D3631) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Unit does not cool No power to unit, breaker tripped Low voltage tripped Loose

More information

TWLC - Tempered Water Logic Controller. The Intelligent Control

TWLC - Tempered Water Logic Controller. The Intelligent Control TWLC - Tempered Water Logic Controller The Intelligent Control Chiller Controls Features: Up to six (6) stages: individual board for each stage maximizes redundancy. Menu driven access and programming.

More information

Modular Air Cooled Scroll Chillers

Modular Air Cooled Scroll Chillers Modular Air Cooled Scroll Chillers 65 80 130 Find out more at www.greeonline.com 160 249 High Efficiency Shell and Tube Heat Exchanger The Gree D Series Chillers utilise high efficiency shell and tube

More information

PDF Created with deskpdf PDF Writer - Trial ::

PDF Created with deskpdf PDF Writer - Trial :: Instruction Manual Index Introduction Uncrating and Checking for Damage Locating Your Unit Installation Fill Tank Process Connections Pre Startup Startup Sequence Trouble Shooting Chart Operating Lights

More information

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help? INSTALLATION MANUAL This manual covers the following models: T955W Master Thermostat Base Module Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency

More information

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.

More information

BasicTroubleshooting Information and Guidelines

BasicTroubleshooting Information and Guidelines BasicTroubleshooting Information and Guidelines BasicTroubleshooting Information and Guidelines Information and Guidelines May 2017 BasicTroubleshooting PRIOR TO CONTACTING CLIMATEMASTER TECHNICAL SUPPORT,

More information

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98 Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 04/11 Supersedes: 12/10 Identification code Index Index... pag. 2 Identification code...»

More information

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA OWNER S MANUAL Models: AC110, AC125, AC150 made from 2003 through 2010 Proudly Made in the USA support@aquacomfort.com www.aquacomfort.com/service-and-support/ (888) 475-7443 Manufacturing High Quality,

More information

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01

More information

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10 Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW Compressors Scroll Serie: Series: Emissione: Issue: SCAEY Catalogo: Leaflet: Sostituisce: Supersedes: DE 88 04/11 12/10 Index

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

Smart Temp. Model

Smart Temp. Model Smart Temp Model 42-160 SINGLE STAGE PROGRAMMABLE THERMOSTAT 1 Heat / 1 Cool Single Stage Thermostat. 5+2 Programmable, Compatible with Gas Heat & Heat Pump System Installation and Operation Manual SPECIFICATIONS:--------------------------------------------------------------------------------

More information

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C Product Data 30RQ Air-cooled Modular Chiller R22 & R410A & R407C Introduction Air-cooled modular chiller is a kind of central airconditioning unit which adopts air as the cooling (or heating) source and

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: N

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: N Packaged air conditioning unit condensed by air model RTC 07L to 30L Ref.: N-27656 0608 Technical information Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT Certification

More information

LZA High efficiency air to water heat pumps with HP compressor

LZA High efficiency air to water heat pumps with HP compressor High efficiency air to water heat pumps with HP compressor -10 C +43 C +60 C HP C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or

More information

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 46 Above picture is only indicative and is not binding AIR FC The packaged air cooled chillers of RAS Kp series are suitable

More information

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017 Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air

More information

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R Packaged air conditioning unit condensed by air model RTC 07L to 30L Ref.: Y-R70167 0707 Technical information I S O 9 0 0 1 ER-0028/1991 Johnson Controls Manufacturing España, S.L. is participating in

More information

OIL COOLER INSTRUCTION HANDBOOK

OIL COOLER INSTRUCTION HANDBOOK OIL COOLER INSTRUCTION HANDBOOK INDEX 1. GENERALITY 2 1.1 OPERATING RANGE 1.2 IMPORTANT 2. INSTALLATION 3 2.1 TRANSPORTATION 2.2 INSTALLATION LOCATION 2.3 PIPING 2.4 WIRING (see the electrical diagram

More information

Air-cooled modular Chiller. Nick Technical Engineer

Air-cooled modular Chiller. Nick Technical Engineer Air-cooled modular Chiller Nick Technical Engineer Product line-up Features Roadmap Product range New product Comparison Reference project Product roadmap Entered air cooled modular chiller market T1/T3

More information

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98 Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 01/16 Supersedes: 12/13 Identification code Index Index... pag. 2 Identification code...»

More information

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start Mokon Troubleshooting Guide Model 311 Process pump will not start Process pump shuts down during operation Pump seal leak Tank overflows or will not fill on systems with autofill option (water makeup valve)

More information

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw TECHNICAL INSTRUCTIONS CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw CHG 1 CHG 1 8. kw. kw.7 kw 1. kw April 7 19 - GB - 2 MARKING This product marked conforms to the essential

More information

Part 1 General Information... 1 Part 2 Outdoor Unit... 4 Part 3 Installation... 45

Part 1 General Information... 1 Part 2 Outdoor Unit... 4 Part 3 Installation... 45 Contents Part 1 General Information... 1 Part 2 Outdoor Unit... 4 Part 3 Installation... 45 The specifications, designs, and information in this book are subject to change without notice for product improvement.

More information

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408 997-060180-5 Installation Instructions / User s Manual TSTAT0406 and TSTAT0408 4 HEAT 2 COOL DUAL FUEL TSTAT0406 & TSTAT0408-4 WIRE CAPABLE THERMOSTAT (NAXA00201DB Daughter Board sold separately) LEFT

More information

Air-Cooled Mini Chiller. Models: AMAC 040 A/AR AMAC 050 A/AR AMAC 058 A/AR AMAC 075 B/BR AMAC 100 B/BR AMAC 125 B/BR. Manual No: TMA-AMAC-1161

Air-Cooled Mini Chiller. Models: AMAC 040 A/AR AMAC 050 A/AR AMAC 058 A/AR AMAC 075 B/BR AMAC 100 B/BR AMAC 125 B/BR. Manual No: TMA-AMAC-1161 Models: AMAC 040 A/AR AMAC 050 A/AR AMAC 058 A/AR AMAC 075 B/BR AMAC 100 B/BR AMAC 125 B/BR Air-Cooled Mini Chiller Manual No: TMA-AMAC-1161 REGISTERED ISO 9002 CONTENTS PAGE 1. NOMENCLATURE SYSTEM...

More information

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.00 kw -. kw PHRT.0 kw /.0 kw

More information

CENTRAL AIR CONDITIONERS MINI CHILLER SERVICE MANUAL

CENTRAL AIR CONDITIONERS MINI CHILLER SERVICE MANUAL CENTRAL AIR CONDITIONERS MINI CHILLER SERVICE MANUAL T/R40A/50Hz (GC2004) CONTENTS PRODUCT...2 MODELS LIST...2. Split Type...2.2 Integral Type...3 2 NOMENCLATURE...3. Split Type...3.2 Integral Type...4

More information

Hi-Pres Cooling Products Catalogue. Product Catalogue

Hi-Pres Cooling Products Catalogue. Product Catalogue Hi-Pres Cooling Products Catalogue Product Catalogue Important Notice This document is provided As is and is subject to change without prior notice. Novenco A/S reserves this right due to continuous product

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

CHILLER. Modelli CWS BASIC CWS AQUACONTROL INSTALLATION MANUAL USAGE AND SCHEMATICS

CHILLER. Modelli CWS BASIC CWS AQUACONTROL INSTALLATION MANUAL USAGE AND SCHEMATICS CHILLER CWS AQUACONTROL Modelli CWS BASIC 121 161 201 251 301 INSTALLATION MANUAL USAGE AND SCHEMATICS A041252 16/10/2012 COMPANY WITH QUALITY SYSTEM CERTIFIED BY DNV =ISO 9001/2000 9001/2008 = ISO VECO

More information

INSTALLATION AND USER MANUAL

INSTALLATION AND USER MANUAL INSTALLATION AND USER MANUAL Thank you for choosing inverter heat pump. This manual provides you necessary information for optimal use and maintenance, please read it carefully and keep it for subsequent

More information

Ice Rink (Single and Dual Configurations) Custom Control Features

Ice Rink (Single and Dual Configurations) Custom Control Features & M&M Refrigeration, Inc. Computer Control System Ice Rink (Single and Dual Configurations) Custom Control Features REVISION DATE DESCRIPTION - 4/20/05 Original release. A 09/21/98 Update Chiller Pump

More information

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING Tempered Water Logic Control OPERATION l TROUBLE SHOOTING English For MPE Multiple Chiller Units Control Panel TEMPERED WATER SYSTEMS L-2199 Rev. 20080223 Revision: L-2199 20101104 *** IMPORTANT NOTICE

More information

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump Catalogue MAC-D-2013 (50Hz) MAC-D R410A Series Air-cooled Modular Chiller/Heat pump Model: Refrigerant: Cooling Capacity: Heating Capacity: MAC210D5-MAC1680D5 MAC230D5-MAC1840D5 MAC210DR5-MAC1680DR5 MAC230DR5-MAC1840DR5

More information

The Book of AERMEC NRL Sequence of Operation

The Book of AERMEC NRL Sequence of Operation The Book of AERMEC NRL Sequence of Operation Heating and cooling operation. 2 Sequence of operation Aermec air to water chiller/heat pump use Hydronic s in conjunction with refrigerant to provide heating

More information

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water

More information

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

Chiller units and air-water heat pumps RANGE OPERATING LIMITS Chiller units and air-water heat pumps Cooling capacity: Heating capacity: 6, to 6,6 kw 8, to 69,4 kw ENVIRONMENTALLY FRIENDLY HFC R407C PROTECTION DE L'ENVIRONNEMENT Silent and compact design Air-conditioning

More information

Safety & Installation Instructions

Safety & Installation Instructions Model 8800 Universal Communicating Thermostat Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS Table of contents Installation Installation location recommendations... 2 Thermostat mounting...

More information

Technical description. Atec.

Technical description. Atec. www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.

More information

User Manual Ichill 200 L/D (Firmware version 1.7)

User Manual Ichill 200 L/D (Firmware version 1.7) User Manual Ichill 2 L/D (Firmware version 1.7) Pag. 1 of 142 INDEX 1. GENERAL FEATURES...8 1.1 Main Function... 8 2. ICHILL 2L/D TABLE OF THE FEATURES...1 3. USER INTERFACE...11 4. REMOTE KEYBOARD...15

More information

CWS AIR-CONDITIONERS

CWS AIR-CONDITIONERS CWS AIR-CONDITIONERS MODUL & MODUL XL INSTALLATION, OPERATION AND MAINTENANCE MANUAL MODUL_GB_2007.doc page 1 of 28 10/04/07 CWS air-conditioners 1 - Installation CONTENTS 1 Installation 2 Commissioning

More information

AIR-COOLED SCREW CHILLER

AIR-COOLED SCREW CHILLER IR-COOLED SCREW CHILLER TRUST IR CONDITIONING EQUIPMENT CO. Prepared y: Engineering & R & D Department. Shiraz- UG 015 Maintenance and Commissioning 1. Commissioning 1.1 Electrical System Connection Inspection

More information

CHILLER. Operator s & Installation Manual

CHILLER. Operator s & Installation Manual CHILLER MODELS: CH1001-A Operator s & Installation Manual Release Date: August 9, 2002 Publication Number: 620914301 Revision Date: May 6, 2010 Revision: E Visit the IMI Cornelius web site at www.cornelius.com

More information

Safety & Installation Instructions

Safety & Installation Instructions 8400 Series Thermostats Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS 61000652C 8400 Tstat Install.indd 1 10/13/09 11:08:56 AM Table of contents Installation Installation location

More information

REMOTE CONTROL FOR CHILLER MYCHILLER

REMOTE CONTROL FOR CHILLER MYCHILLER REMOTE CONTROL FOR CHILLER MYCHILLER GENERAL FEATURES... 3 MAIN FUNCTIONS AND EQUIPMENT:... 3 LCD DISPLAY... 4 KEYBOARD... 5 BOARD CONFIGURATION... 7 LIST OF MAIN PARAMETERS... 7 CONFIGURATION OF MAIN

More information

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB R407C EASY_R Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans 5,2 41,5 kw T_ESY_R_0508_GB EASY_R R407C INDEX WORKING LIMITS... 3 SERIES IDENTIFICATION... 4 MODEL

More information

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures

More information

ECB Specification: Electric control box: W 300 * H 400 * D 150 (mm)

ECB Specification: Electric control box: W 300 * H 400 * D 150 (mm) ECB-5070 General descriptions: This product has the function of current display and motor integrated, which can effectively avoid the various danger caused by the instability of current and voltage, to

More information

Parts introduction FRONT BACK

Parts introduction FRONT BACK Lando Industrial Water Chillers installation instructions Thank you for using the machine from Shenzhen Lando Technology Industrial Co.,Ltd.. Please read the installation instructions carefully before

More information

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort User manual CLIMATIC 2/4 - Controller Providing indoor climate comfort MUL35E-56 9-26 INDEX CONTENTS PAGE INDEX 1 GENERAL DESCRIPTION 2 THE KEYPAD, Climatic 2 3 THE KEYPAD, Climatic 4 4 THE KEYPAD REMOTE

More information

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table) 1 2 Warning: - Do not place your hand or any other objects into the air outlet and fan. It could damage the heat pump and cause injuries; - In case of any abnormality with the heat pump, cut off the power

More information

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS ORTEC Compressed Air, Gas & Fluid Technologies HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS Energy Lean Planet Green Cycling and Non-Cycling Design Energy Efficient s Fluctuating and Intermittent Loads Capacity,0

More information

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79 MCAC-TSM-2008-02 Contents Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79 Contents i MCAC-TSM-2008-02 Introduction Introduction Midea Mini Unitary

More information

Trouble Shooting Guide RAA, 1-phase (D3627)

Trouble Shooting Guide RAA, 1-phase (D3627) Trouble Shooting Guide RAA, 1-phase (D3627) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Unit does not cool No power to unit, breaker tripped Low voltage tripped Loose

More information

E U R O V E N T CERTIFIED PERFORMANCE

E U R O V E N T CERTIFIED PERFORMANCE Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L Ref.: Y-R70171 0707 Technical information E U R O V E N T CERTIFIED PERFORMANCE I S O 9 0 0 1 ER-0028/1991 Johnson Controls Manufacturing España,

More information

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 +63 E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

Trouble Shooting Guide PAA, 1-phase (D3731)

Trouble Shooting Guide PAA, 1-phase (D3731) Trouble Shooting Guide PAA, 1-phase (D3731) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Unit does not cool No power to unit, breaker tripped Low voltage tripped Loose

More information

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Большая библиотека технической документации   каталоги, инструкции, сервисные мануалы, схемы. Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive,

More information

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES Water to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures

More information

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

HYDROCIAT LW R407C. Water cooled chillers USE RANGE Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

Hayward/Summit Heat Pump Troubleshooting Guide Hayward Industries

Hayward/Summit Heat Pump Troubleshooting Guide Hayward Industries Hayward/Summit Heat Pump Troubleshooting Guide 2012 Hayward Industries Leave Blank- Inside Front Cover Heat Pumps Covered by This Guide HeatPro HP50TA, HP20654T, HP20654BT, HP20654TC, HP20854T, HP20854BT,

More information

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC. WYETH-AYERST CANADA INC. 1025, BOUL. MARCEL-LAURIN S T - L A U R E N T, Q U É B E C INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER MODEL P448800LT--55WC--22C66S Prepared par Claude Gadoury, P.

More information

Safety & Installation Instructions

Safety & Installation Instructions 8400 Series Thermostats Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS 61000652A 8400 Tstat Install.indd 1 7/23/09 2:20:45 PM Table of contents Installation Installation location recommendations...

More information

Product Catalogue CG-PRC002E-EN. CGAD Liquid Chillers Air-Cooled Scroll Compressor 20 to 150 Tons. July Models: 50 / 60 Hz

Product Catalogue CG-PRC002E-EN. CGAD Liquid Chillers Air-Cooled Scroll Compressor 20 to 150 Tons. July Models: 50 / 60 Hz Product Catalogue CGAD Liquid Chillers Air-Cooled Scroll Compressor 20 to Tons Models: 50 / 60 Hz CGAD CGAD CGAD CGAD CGAD CGAD CGAD CGAD CGAD CGAD CGAD CGAD July 2012 CG-PRC002E-EN Introduction IMPORTANT:

More information

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45 Plug & Heat heat pump Quick and easy to install For new homes or boiler backup operation 50 HFC R410A CERTIFIED BY CERTITA Heating capacity: 5.5 to 22 kw option CERTIFIED BY CERTITA 30/35-40/45 USE The

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

Air Cooled Module Water Chiller

Air Cooled Module Water Chiller Air Cooled Module Water Chiller Installation, operation and technical manual Heat pump / Cooling only R22 refrigerant 33KW, 65KW 3PH, 380V~400V, 50Hz Haier Commercial Air Conditioning MANUAL CODE: SYJS-012-06REV.0

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

Heated and Refrigerated Incubators

Heated and Refrigerated Incubators Heated and Refrigerated Incubators MIR-162-PA MIR-262-PA MIR-154-PA MIR- 254-PA MIR-554-PA us.panasonic-healthcare.com powered by TM Heated and Refrigerated Incubators Panasonic MIR series incubators are

More information

air systems Roomtop RTC-RTH 15 to 30 - L

air systems Roomtop RTC-RTH 15 to 30 - L air systems Roomtop RTC-RTH 15 to 30 - L york air-conditioning products Roomtop RTC-RTH - L A complete range from 14.6 kw up to 27.0 kw YKN2open Features New YKN2open board Possibility to be installed

More information