1 ISCEON 9 Series Refrigerants P R O D U C T I N F O R M A T I O N G U I D E Refrigerants. The Science of Cool. TM de Nemours International S.A. 2 Chemin du Pavillon P.O. Box 50 CH-1218 Le Grand-Saconnex Geneva, Switzerland Tel: Fax: EU-info@dupont.com Copyright All rights reserved. The Oval Logo,, The miracles of science, The Science of Cool and ISCEON are registered trademarks or trademarks of or its affiliates. K /08
2 pioneered much of the science that makes air conditioning and refrigeration possible. With over 75 years of proven leadership in s science and technology, we offer the broadest range of solutions for new and existing equipment, and we are committed to leveraging The Science of Cool to lead the search for new cooling solutions that improve comfort and enhance the quality of life around the world. This guide contains information on our full line of ISCEON 9 Series Refrigerants to help you select the best for your application. Additional product information is available on our website, or by contacting your local Refrigerants distributor. ISCEON 9 Series Refrigerants Efficient and cost effective, Non-ozone-depleting, HFC retrofit s for CFC and HCFC equipment. ISCEON MO29 Multi-purpose replacement for R-22 in direct expansion equipment (Air Conditioning and Medium/Low Temperature Refrigeration) ISCEON 39TC R-12 in centrifugal chillers ISCEON MO49Plus R-12, R-413A, R-401, R-409A in automotive air conditioning and stationary air conditioning/refrigeration ISCEON MO59 Best suited to replace R-22 in small A/C (<15kW) systems ISCEON MO79 Best suited as a replacement for : R502, R402, R403, R408 series blends ISCEON MO89 R-13B1 in very low-temperature refrigeration Efficient and cost-effective. Compatible with traditional and new lubricants. Avoid costly equipment replacement. Available from a name you can trust. Refrigerants. The Science of Cool. We ve worked hard to build a website that works as hard as you do with customized sections dedicated to OEMs, distributors, service technicians and end users for a better, more efficient way to explore cooling solutions. When you re looking for high-quality, high-performance cooling solutions from a trusted source, visit 2 3
3 ISCEON MO29 ISCEON MO29 is one of the leading multipurpose replacements for R-22 in existing direct expansion water chiller systems, residential, commercial air conditioning and medium/low temperature refrigeration systems. R-422D R-22 Multi-purpose replacement for R-22 in direct expansion equipment (air conditioning, water chiller systems and medium/low temperature refrigeration). Non-ozone-depleting HFC retrofit s in most cases, no change of lubricant type is needed Enables continued use of existing equipment Close match to R-22 capacity and efficiency in most systems Lower discharge temperature vs. R-22-likely to prolong the life of the compressor in some systems ISCEON MO29 is compatible with traditional and new lubricants, including mineral oil, alkylbenzene and polyol ester. In most cases, no change of lubricant type during retrofit is needed. See Product Information Bulletin and retrofit guidelines for additional information. ISCEON 39TC ISCEON 39TC is one of the leading, non-ozonedepleting HFC retrofit s for R-12 in centrifugal chillers. R-423A R-12 Centrifugal chillers designed for R-12 Non-ozone-depleting HFC retrofit s Retrofit typically requires a single lubricant change to polyol ester without additional flushing Avoids expensive engineering changes to existing chiller equipment Enables cost-effective, continued use of existing chiller equipment Provides required cooling capacity and comparable energy efficiency vs. R-12 Similar discharge temperature and pressure vs. R-12 For most systems, only one lubricant change to polyol ester during retrofit is required. ISCEON 39TC tolerates high residual levels of mineral oil in polyol ester; therefore, no system flushing is generally required after changing the original lubricant to polyol ester. See ISCEON 39TC Retrofit Guidelines for more details. 4 5
4 ISCEON MO49Plus ISCEON MO49Plus is a cost-effective, non-ozonedepleting HFC retrofit for R-12 automotive and stationary air conditioning in direct expansion mediumtemperature stationary refrigeration systems. R-437A (pending) TM R-12, R-413A, HCFC-containing blends (e.g. MP39, MP66, R-409A) Automotive AC systems designed for R-12 Refrigeration systems, designed for R-12 including: food service supermarket display cases food storage and processing domestic refrigerators/freezers Provides cost-effective retrofits Non-ozone-depleting HFC retrofit in most cases, no change of lubricant type is needed Enables continued use of existing equipment ASHRAE safety classification of A1 (see AS-1 bulletin and MSDS) Provides up to 10% better cooling capacity vs. R-12 Provides similar to slightly lower energy efficiency vs. R-12 Lower discharge temperature vs. R-12 For R-12 automotive air conditioning systems, ISCEON MO49Plus is compatible with mineral oil in existing R-12 systems. In most cases, no change of lubricant type during retrofit is needed. For R-12 stationary medium-temperature refrigeration and air conditioning systems, ISCEON MO49Plus is compatible with traditional and new lubricants mineral oil, alkylbenzene and polyol ester. In most cases, no change of lubricant type during retrofit is needed. Refer to ISCEON MO49Plus Retrofit Guidelines for more details. ISCEON ISCEON MO59 is an efficient and cost-effective, non-ozone-depleting HFC retrofit for R-22 in direct expansion air conditioning. Best suited to replace R-22 in small A/C (<15kW) systems R-417A R-22 MO59 Split air conditioning systems Note: for water chillers ISCEON MO29 is recommended Non-ozone-depleting HFC retrofit s in most cases, no change of lubricant type during retrofit is required Enables the continued use of existing equipment ASHRAE safety classification of A1 (see AS-1 bulleting and MSDS) Lower discharge temperature and pressure vs. R-22-likely to prolong the life of the compressor Has been shown to offer energy savings in some systems ISCEON MO59 is compatible with traditional and new lubricants, including mineral oil, alkylbenzene and polyol ester. In most cases, no change of lubricant type during retrofit is needed. See the ISCEON MO59 Retrofit Guidelines for more details. 6 7
5 ISCEON MO79 ISCEON MO79 is one of the leading non-ozone depleting HFC s for replacing R-502 and R-402, R-403 and R-408 series HCFC-containing blends in commercial and industrial direct expansion refrigeration systems. R-422A R-22, R-502, HCFC-containing blends Best suited as a replacement for: R502, R402, R403, R408 series blends. Also R-22 in certain low temperature applications. -easier retrofit than R-404A and R-507 Non-ozone-depleting HFC retrofit s in most cases, no change of lubricant type during retrofit is required Enables continued use of existing equipment 20% lower Global Warming Potential (GWP) vs. R-404A and R-507 Provides improved cooling capacity over R-22 at many operating conditions with up to +15% at low-temperature conditions Provides comparable cooling capacity to R-404A and R-507 Field testing shows it can provide improved energy efficiency vs. R-22 Lower discharge temperature vs. R-22-likely to prolong the life of the compressor ISCEON MO89 ISCEON MO89 is a non-ozone-depleting HFC retrofit for R-13B1 in very low-temperature direct expansion refrigeration systems. None assigned R-13B1 Very low-temperature refrigeration (below 40 C to 70 C), including: freeze driers medical freezers environmental chambers Non-ozone-depleting HFC Compatible with traditional and new lubricants in most cases, no change of lubricant type during retrofit is needed After retrofit, can be topped off during service without removing the entire charge Provides cooling capabilities similar to R-13B1 ISCEON MO89 is compatible with traditional and new lubricants mineral oil, alkylbenzene and polyol ester. In most cases, no change of lubricant type during retrofit is needed. See the ISCEON MO89 Retrofit Guidelines for details. ISCEON MO79 is compatible with traditional and new lubricants, including mineral oil, alkylbenzene and polyol ester. In most cases, no change of lubricant type during retrofit is needed. See the ISCEON MO79 Retrofit Guidelines for details. 8 9
6 Safe Handling Like the s they replace, ISCEON 9 Series Refrigerants are safe to use when handled properly. Because any can be hazardous when improperly handled, refer to the Material Safety Data Sheet (MSDS) for proper handling procedures. For additional safety information on ISCEON 9 Series Refrigerants, refer to bulletin Safety of Refrigerants (AS-1). For detailed information on the Properties, Uses, Storage and Handling (PUSH) of ISCEON 9 Series Refrigerants, refer to the appropriate PUSH bulletin. Product Availability ISCEON 9 Series Refrigerants are available from our global network of Refrigerant distributors. To find the local Refrigerant distributor nearest to you, visit Refrigerants Vision: The Science of Cool We will use our science and technology, market knowledge and global reach to provide sustainable materials and solutions to enhance personal comfort, enable food preservation, improve industrial processing and reduce environmental footprints. or call us at or fax at or at EU-info@dupont.com 10 11
DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options
DuPont Refrigerants R22 market and the ISCEON retrofit options Airefrig November 2010 John McCormack Business Manager DuPont Chemicals and Fluoroproducts HCFC Regulations & ISCEON 3 Actions Impacting Fluorochemicals
More informationR-407A R-448A R-449A
GUIDELINES FOR THE UTILIZATION OF R-407A R-448A R-449A 2018 Tecumseh Products Company LLC. All rights reserved. Page 1 of 9 R-407A, R-448A, and R-449A are recognized as suitable alternative refrigerants
More informationDuPont FE-25 FIRE EXTINGUISHANT. Preferred Replacement for Existing Systems and the Choice for New Applications
DuPont FE-25 FIRE EXTINGUISHANT Preferred Replacement for Existing Systems and the Choice for New Applications FE-25 is particularly well-suited for sensitive appliactions, such as clean rooms Protecting
More informationThe natural solution for domestic refrigeration
The natural solution for domestic refrigeration 1300 492 445 info@hychill.com.au Minus 10 is a high-purity R600a (isobutane), the dominant single-ingredient refrigerant used in state-of-the-art light commercial
More informationChapter 2. Alternatives to HCFCs and their Characteristics
Alternatives to HCFCs and their Characteristics Refrigerant - General Chemical used in a cooling system, such as an air conditioner or refrigerator, as the heat carrier which changes from vapour to liquid
More informationREFRIGERANT REFERENCE GUIDE
United States National Refrigerats, Inc. 1140 Roosevelt Boulevard Philadelphia, PA 19154 215-698-6620 800-262-0012 Fax: 215-698-7466 United Kingdom National Refrigerants of America Ltd. 4 Watling Close
More informationA: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.
1/1/12 RS-45 (R434A): Q & A 1 Q: What is RS-44? 1.Q: What is RS-45 A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. 2 Q: Yes, but what does RS-45 contain? A: RS-45 is
More informationPAYING THE PIPER TABLE 1 NEOPRENE TYPE W SWELL RATES
BY DAVE DEMMA PAYING THE PIPER This is the third and final installment explaining the conversion of a refrigeration system from an HCFC (R22) to an alternative, probably an HFC (R404A or R507). There are
More informationReference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.
GUIDELINES FOR THE UTILIZATION OF R-404A R-452A Page 1 of 10 GUIDELINES FOR THE UTILIZATION OF R-404A AND R-452A For many years, R-404A has emerged as the industry's major choice as an alternative refrigerant
More informationNZQA Expiring unit standard 3397 version 4 Page 1 of 5. Convert an automotive air conditioning system from R-12 to R-134a
Page 1 of 5 Title Convert an automotive air conditioning system from R-12 to R-134a Level 3 Credits 2 Purpose This unit standard is for people in the automotive repair industry. People credited with this
More informationWorldwide Marine and Offshore Services A GUIDE TO RS REFRIGERANTS FROM STAR INTERNATIONAL. Second Edition
Worldwide Marine and Offshore Services A GUIDE TO RS REFRIGERANTS FROM STAR INTERNATIONAL Second Edition STAR DISTRIBUTION CENTRES WORLDWIDE Argentina (to be opened shortly) Australia Bahrain Belgium Brazil
More informationPublication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS
Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS Refrigerant R22 is widely used for residential and commercial air conditioning, as well as commercial refrigeration
More informationFACT SHEET 6 Transport Refrigeration
UNEP Ozone Secretariat Fact Sheets on HFCs and Low GWP Alternatives UNEP Ozone Secretariat Background Material on HFC Management October 205 FACT SHEET 6 Transport Refrigeration. Description of market
More informationDue to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.
TECHNICAL DATA SHEET R434A () Features and uses of R-434A () is a non-flammable HFC mixture. ODP = 0, compatible with traditional mineral lubricants, alkyl benzene and also with synthetic POE, so there
More informationThe R-404A Challenge. Commercial Opteon Refrigerant Solutions - The New Industry Standard
Opteon Refrigerants The R-404A Challenge. Commercial Opteon Refrigerant Solutions - The New Industry Standard Mark Hughes Business Development Manager Opteon Refrigerants Agenda Intro Chemours The Chemical
More informationScroll Chillers Transition from HCFC-22 to HFCs
Scroll Chillers Transition from HCFC-22 to HFCs An HVAC Manufacturer s Perspective Todd Brown McQuay International Business Development Manager Chillers todd.brown@mcquay.com ICF Workshop, Montreal Canada,
More informationRefrigerants & Cooling in renovation buildings
Refrigerants & Cooling in renovation buildings 01 Basics Refrigeration circuit. 1 Refrigeration Basics LP HP Mollier Diagram A-C Evaporation B-C Superheat C-D Compression D-E Desuperheat D-G Condensation
More informationRefrigerants Management & Retrofits. Mike Saunders & Randy Tebbe Emerson Climate Technologies
Refrigerants Management & Retrofits Mike Saunders & Randy Tebbe Emerson Climate Technologies Agenda Refrigerant Landscape and Proposed Regulation Review Life Cycle Climate Performance Refrigerant Phase-Down
More informationRetrofit Guidelines for DuPont ISCEON M029 (R-422D) Refrigerant
DuPont ISCEON 9 Series REFRIGERANTS Technical Information ART-46 Retrofit Guidelines for DuPont ISCEON M029 (R-422D) Refrigerant Retrofit Guidelines for DuPont ISCEON 9 Series Refrigerants Table of Contents
More informationAlternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration
Alternatives in the AC & Chiller Sectors Sukumar Devotta and Lambert Kuijpers OORG Refrigeration 1 Outline ASHRAE position paper summary which marks a difference in the US approach dealing with various
More informationFlammability and the Low GWP Refrigerant Challenge
Flammability and the Low GWP Refrigerant Challenge A Presentation to the BSRA Presentation On Guy Fawkes Night 5 th November 2015 Presented by Dewi Garcia MSc, MInstR Technical Manager Harp International
More informationGuidance for Stationary Refrigeration & Air-Conditioning
Information Sheet RAC 2 - Usage Guidance for Stationary Refrigeration & Air-Conditioning This Information Sheet provides background information about the use of stationary refrigeration, airconditioning
More informationCurrent use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration
Current use of HFCs and HCFCs. Trends, alternatives and climate impact YEREVAN, Armenia, May 18-19, 2009 Didier COULOMB, Director of the IIR, d.coulomb@iifiir.org Institut du Froid (IIF) - www.iifiir.org
More informationEC Regulation No 842/2006 on certain fluorinated greenhouse gases
www.defra.gov.uk EC Regulation No 842/2006 on certain fluorinated greenhouse gases Supplementary Guidance for Stationary Refrigeration Airconditioning and Heat Pump Users February 2007 Department for Environment,
More informationR-404A Alternative with Low Compressor Discharge Temperature
2175, Page 1 R-404A Alternative with Low Compressor Discharge Temperature Barbara MINOR 1 *, Vladimir SULC 2, Jeff BERGE 3, Michal KOLDA 4, Michal HEGAR 5 1 DuPont, Fluoroproducts, Wilmington, DE, USA
More informationa. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system
Core 1. Ozone in the stratosphere above the earth consists of: a. Molecules containing 3 oxygen atoms. b. Molecules of 2 oxygen atoms. c. Radioactive particles. d. Pollutants that have risen from ground
More informationLow GWP alternative refrigerants to R404A
HUAYI Statement: Low GWP alternative refrigerants to R404A Live the cooling experience The Company: HUAYI COMPRESSOR BARCELONA (HCB) The HCB of today started out with Spanish and French capital in 1962,
More informationQ. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:
Basic Facts About Hydrocarbons Q. What are hydrocarbons? Hydrocarbon refrigerants are environmentally friendly, non-toxic, non-ozone-depleting replacement for chlorofluorocarbons (CFCs), hydrochlorofluorocarbons
More informationOverview of New Refrigerants and Expected Market Trends
OEWG 35, Side Event by EPEE: Open debate on global trends and developments to reduce HFC emissions - an industry perspective Overview of New Refrigerants and Expected Market Trends Presentation by Ray
More informationUpdate on Refrigerant Blends
Update on Refrigerant Blends 11 th Annual Financial Agent Workshop The World Bank 26-27 27 March 2007 Steven R. Szymurski Director of Research Air-Conditioning & Refrigeration Institute About ARI www.ari.org
More informationRS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:
TECHNICAL DATA SHEET Features and uses of is a non-azeotropic blend of HFC with zero Ozone Depletion Potential et low Global Warming Potential (GWP), formulated to meet the requirements of the F-Gas Regulation
More informationNew Refrigerants & Selecting Capital Equipment
F-GAS Refrigerants & Selecting Capital Equipment AN I N T E R N A T I O N A L R E F R I G E R A T I O N G R O U P Refrigerants for Capital Equipment Selections Fluorinated gases (F-gases) are a family
More informationFACT SHEET 9 Large Air-Conditioning (air-to-air)
UNEP Ozone Secretariat UNEP Ozone Secretariat Background Material on HFC Management Fact Sheets on HFCs and Low GWP Alternatives October 205 FACT SHEET 9 Large Air-Conditioning (air-to-air). Description
More informationHoneywell Refrigerant Update
Honeywell Refrigerant Update Honeywell s refrigerants key attributes Environment HONEYWELL - CONFIDENTIAL 2 Fluorine Products A history of innovation Energy efficiency Environmental compliance Montreal
More informationENERSAVE Hydrocarbon Scroll Water Cooled Chiller
ENERSAVE Hydrocarbon Scroll Water Cooled Chiller Your Green Input to Chiller ever found in the market To eliminate the threat of environmental impact by utilizing environmental friendly refrigerant gas-
More informationSolstice 452A (R-452A) Reduced GWP and Discharge Temperature for Transport Refrigeration, Plug-Ins and Condensing Units
Low- and MediumTemperature Refrigeration Reduced GWP and Discharge Temperature for Transport Refrigeration, Plug-Ins and Condensing Units Solstice 452A (R-452A) Characteristics Solstice 452A (R-452A) is
More informationEffectively Managing the Transition to Lower GWP Refrigerants
Effectively Managing the Transition to Lower GWP Refrigerants Karim Amrane, Ph.D. Senior Vice President Air-Conditioning, Heating, and Refrigeration Institute 12 th IEA Heat Pump Conference 2017 May 15-18,
More informationNew Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA
New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA 5 th March 2014 Honeywell $39-39.5B in sales* 54% sales outside U.S. 1,300 sites, 70 countries 132,000 employees Morristown,
More informationSustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn
Sustainable Refrigerant Solutions for HVAC-R Laurent Abbas, Wissam Rached, Brett Van Horn 2014 ASHRAE Annual Conference Seattle, WA July 1, 2014 Learning Objectives 1. Design refrigeration and air-conditioning
More informationnatural refrigerants - global trends & developments
natural refrigerants - global trends & developments February 3, 2014 Nina Masson, Head of Market Research shecco Japan a wide range of applications for natural refrigerants a wide range of applications
More informationMaking equipment decisions
Making equipment decisions in a changing landscape of refrigerant legislation A QUICK GUIDE As the HVAC and building management industry navigates the complex and ever-changing refrigerant landscape, many
More informationThe Current Path of Refrigerants
The Current Path of Refrigerants Rick Wentling NA Market Development Manager Opteon Stationary Refrigerants November 9, 2017 Prediction is very difficult; especially if it s about the future. - Neils Bohr
More informationFACT SHEET 9 Large Air-Conditioning (air-to-air)
FACT SHEET 9 Large Air-Conditioning (air-to-air) UNEP Ozone Secretariat UNEP Ozone Secretariat Background Workshop Material for on HFC HFC Workshop, management: 205 technical issues Bangkok, 20 and 2 April
More informationUpdate on Next Generation Low GWP Refrigerants for Chillers Products. Steve Kujak Director, Next Generation Refrigerant Research
Update on Next Generation Low GWP Refrigerants for Chillers Products Steve Kujak Director, Next Generation Refrigerant Research The International Symposium on New Refrigerants and Environmental Technology
More informationETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming
ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming 88 KENJI UEDA *1 YOSHINORI SHIRAKATA *2 YASUSHI HASEGAWA *3 NORIYUKI MATSUKURA *4 NAOYA MIYOSHI
More informationUpdate on Opteon Refrigerants
Update on Opteon Refrigerants In Bae Lee AP Marketing Manager, FluoroChemicals Chemours Company Spetember 20, 2018 The Chemours Company Source: Jeffries 2018 Industrials Conference, August 2018 2 Evolution
More informationScroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C
Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C McQuay International (A Member of the DAIKIN Group) Hydrofluorocarbon (HFC) refrigerants are critical to the safe and cost-effective phase-out
More informationSuva refrigerants. Suva 134a (HFC-134a) for Mobile Air Conditioning. Technical Information. Introduction. Transition to HFC-134a
Technical Information f Suva refrigerants Note: This publication supersedes Bulletin ART-12. ART-27 Suva 134a (HFC-134a) for Mobile Air Conditioning Introduction In the past almost all mobile air conditioning
More informationThe complete approach to the care and management of A/C & refrigeration systems
The complete approach to the care and management of A/C & refrigeration systems Testing oil with the Phase III Refrigeration Oil Acid Test Kit Flushing with OEM endorsed R x 11-flush Acid removal with
More informationBe sustainable while protecting your business
Be sustainable while protecting your business Aquaflair 50Hz Air-cooled chillers and free-cooling chillers with double screw compressors and HFO R1234ze refrigerant (400V/3ph/50Hz) 300-1000 kw Aquaflair
More informationRefrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A Leading the Industry with Environmentally Responsible Refrigerant Solutions Emerson Climate Technologies, Inc. does not advocate
More informationReducing Refrigerant Leakage
Reducing Refrigerant Leakage Mike Nankivell F.Inst.R Marketing Director Space Airconditioning plc President of HEVAC Chairman ACRIB F Gas Group An Introduction to Real Zero Information provided by Cool
More informationNew F-Gas Regulation (2014): Guidance for Food and Drink Manufacturers. REI Guide 4a. The 2014 EU F-Gas Regulation
REI Guide 4a The 2014 EU F-Gas Regulation REI Guide 4a: F-Gas Regulation Guidance Chapters 1. Introduction... 3 2. Summary of Key Features of the new F-Gas Regulation... 4 3. Phase Down of HFC Supply...
More informationEnergy Efficiency & Environmental News: CFC Replacements 1
September 1993 Energy Efficiency & Environmental News: CFC Replacements 1 Florida Energy Extension Service and Mike West 2 CFC REPLACEMENTS: KEEPING YOUR COOL AND THE OZONE LAYER As most everyone has heard,
More informationEnergy Saving & Eco-Friendly Refrigerant
Technical Seminar Energy Saving & Eco-Friendly Refrigerant Presented By Eva Yim Business Development Director Stephen Cheung Engineering Director Date : Oct 16, 2012 Others 25% Lighting 15% Air Conditioning
More informationDaikin s Policy. and Comprehensive Actions on the Environmental Impact of
Daikin s Policy and Comprehensive Actions on the Environmental Impact of Refrigerants Daikin provides homes, businesses and industries worldwide with cooling, heating and refrigeration solutions. We also
More informationChillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU
Chillers and Refrigerants APPA Institute for Facilities Management Providence, RI September, 2017 1 Purpose of Today s Presentation To provide a broad understanding of chillers and central cooling systems
More informationRefrigerants for commercial refrigeration applications
Refrigerants for commercial refrigeration applications March 2015 Contents Executive summary... 2 Introduction and background... 2 Environmental drivers... 3 Regulations and timing... 5 Criteria for refrigerant
More informationIndustry co-operation on Natural Refrigerant technology development Kenji Matsuda
Industry co-operation on Natural Refrigerant technology development 2014.02.04 Kenji Matsuda Copyright 2014 JRAIA About JRAIA History The Japan Refrigeration and Air Conditioning Industry Association (JRAIA)
More informationGEA Blu chillers. GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers
GEA Blu chillers GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers 3 Balanced to your benefit, in a class of their own Whether for food and beverage industry, process
More informationGary Parker Refrigerants Product Manager
Gary Parker Refrigerants Product Manager Refrigerant f i t History Status of the HCFC ( R22) Phase out Ozone Friendly Alternativesti Choosing the Best Retrofit Solution Lubricants and how they impact performance
More informationOverview of Alternatives and Climate Impact Scenarios Report of Decision XXV/5 Montreal Protocol
Reunión de las Redes de Funcionarios de Ozono de México, Centro América, Sur América y el Caribe de habla hispana Quito, Ecuador, agosto de 2014 Overview of Alternatives and Climate Impact Scenarios Report
More informationBulletin , March Electric Hot Gas Bypass Valves
Bulletin 100-60, March 2018 Electric Hot Gas Bypass Valves PAGE 2 / Bulletin 100-60 10 FEATURES AND BENEFITS SDR-4 Direct temperature control Tight shutoff when closed Can be interfaced with direct digital
More informationEngineered for flexibility and performance
Centrifugal Chillers 200 to 2700 tons Engineered for flexibility and performance Daikin McQuay Single Compressor Centrifugal Chillers A Life Cycle Return on Your Investment Centrifugal chillers are a significant
More informationRefrigerants. Refrigerants with the Future in Mind
Refrigerants Refrigerants with the Future in Mind Honeywell Refrigerants Products Guide Commercial Refrigeration Replaces ASHRAE Number GWP AR4 AR5 Chemical Name Blend Components Molecular Weight (g/mol)
More informationCHAPTER 1 INTRODUCTION
CHAPTER 1 INTRODUCTION 1.1 CFC REFRIGERANTS Since the 1930s, chlorofluorocarbons (CFCs) have been widely used as foam blowing agents, aerosols and especially refrigerants due to their pre-eminent properties
More informationGeneral Guidance. The easiest way to establish the amount of refrigerant in the system is to use data supplied by the manufacturer:
Information Sheet GEN 5 Refrigerant Quantity General Guidance 1. How much refrigerant is in the system? If you have established that you are using an HFC refrigerant in a refrigeration system, the next
More informationHarold Ag & Mobile Products
TM Harold Ag & Mobile Products Your Ag A/C Parts Specialist 1-800-541-8910 www.heco.net R E F R I G E R A N T S 6-18-13 FR-12 COMPARED TO OTHER BLENDS UL Classified A1/A1 (non-flammable!) ASHRAE Listed
More informationThermodynamics I. Refrigeration and Heat Pump Cycles
Thermodynamics I Refrigeration and Heat Pump Cycles Dr.-Eng. Zayed Al-Hamamre 1 Content Introduction The Reversed Carnot Cycle The Ideal Compression Refrigeration Systems Deviation from the ICRS Selection
More informationPREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17
PREPARE FOR CHANGE LOW GWP ALTERNATIVES November 17 F-GAS PHASE DOWN Where we are now F-Gas regulation places restrictions on the use of some HFC refrigerants of high GWP. This is indirectly achieved by
More informationGo Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Walk-in Coolers & Freezers - OEMs, North America. Over
Danfoss Solutions for Walk-in Coolers & Freezers - OEMs, North America Go Beyond Cool With Danfoss, build sustainable and efficient walk-in coolers & freezers. Our wide range of products and market leading
More informationHoneywell Refrigerants. Retrofit Guidelines. R-404A/R-507A to: R-448A Solstice N40
Honeywell Refrigerants Retrofit Guidelines R-404A/R-507A to: R-448A Solstice N40 Table of Contents Introduction... 1 Solstice Refrigerants... 1 R-448A is not a Drop-in Replacement... 1 Retrofit Procedures...
More informationPossibilities of the RAC sector transformation a technical perspective
A Sustainable transformation of the Refrigeration and Air-conditioning sector Possibilities of the RAC sector transformation a technical perspective The Delegation of the European Union in India and GIZ
More informationThe 10 th Three Associations Meeting JRAIA. The Japan Refrigeration and Air Conditioning Industry Association. August 31, 2016.
The 1 th Three Associations Meeting JRAIA The Japan Refrigeration and Air Conditioning Industry Association August 31, 216 Jeju, Korea 1 Contents 1. Domestic Market Update 2. Implementation of Alternative
More informationGo Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - OEMs, Europe. Over
Danfoss Solutions for Cold Rooms - OEMs, Europe Go Beyond Cool With Danfoss, build sustainable and efficient cold rooms. Our wide range of products and market leading application expertise enable you to
More informationRefrigerant changeover guidelines
Refrigerant changeover guidelines HCFC R-22 to HFC R-407A/F, R-448A or R-449A for medium and low temperature applications HCFC R-22 to HFC R-407C for high, medium and low temperature applications HCFC
More informationRAK THE OPTIMUM RANGE FROM REFCOOL THE ENERGY REVOLUTION. Industrial chillers - 0 to 200 kw
THE OPTIMUM RANGE FROM REFCOOL Industrial chillers - 0 to 200 kw RAK THE ENERGY REVOLUTION WELCOME TO REFCOOL With over 30 years of experience in the industrial water chiller industry, we understand the
More informationRefrigerants and lubricants
Refrigerants and lubricants GENERAL INFORMATION When choosing a refrigerant, different aspects must be taken into consideration: Legislation (now and in the future) Safety Application envelope in relation
More information2017 Climate & Refrigerants Outlook. Stephen Yurek President & CEO
2017 Climate & Refrigerants Outlook Stephen Yurek President & CEO Much Has Occurred There is Much to Come Kigali is Merely the Beginning AHRI is a Trade Association 315: Member Companies: Over 95% of all
More informationThe Changing State of Refrigerants. Gary Parker Refrigerants Product Manager
The Changing State of Refrigerants Gary Parker Refrigerants Product Manager The Changing State of Refrigerants Acronyms you may want to know CARB California Air Resources Board GWP Global Warming Potential
More informationNatural Refrigerants.
Natural Refrigerants www.instituteofrefrigerationireland.ie Seamus Kerr BE, MEngSc, MIEI, MIRI seamus@rslireland.com www.instituteofrefrigerationireland.ie Reminder on terminology: CFC : R12, R502, R11
More informationNatural refrigerant trends in EU, Japan & North America
Natural refrigerant trends in EU, Japan & North America Paris, 17 July 2014 Klara Skacanova, senior analyst shecco Agenda Policy action & market for natural refrigerants: EU Japan North America Europe:
More informationGary Parker Refrigerants Product Manager
Gary Parker Refrigerants Product Manager Refrigerant History Status of the HCFC ( R22) Phase out Ozone Friendly Alternatives Choosing the Best Retrofit Solution Lubricants and how they impact performance
More informationInformation for practitioners 5. Refrigerant selection guidelines. An overview of the refrigerants of the future.
Information for practitioners 5 selection guidelines. An overview of the refrigerants of the future. Helping you choose the right refrigerant. You can rely on our expertise Selecting the right refrigerant
More informationAir conditioning 23XRV
High-Efficiency ChillerS with screw compressors Air conditioning Control CCN - Carrier Comfort Network Features The Evergreen range offers superior solutions with record capacities from 970 to 1880 kw,
More informationGo Beyond Cool. coldroom.danfoss.co.uk. Danfoss Solutions for Cold Rooms Installers/Contractors, Europe. Over
Danfoss Solutions for Cold Rooms Installers/Contractors, Europe Go Beyond Cool With Danfoss, you get more than reliable solutions for cold rooms. Contractor-friendly products built with market leading
More informationAPS Chiller Seminar. Don Brandt, CEM-AEE, BEAP-ASHRAE ASHRAE and IEEE Life Member 3/16/2017
APS Chiller Seminar Don Brandt, CEM-AEE, BEAP-ASHRAE ASHRAE and IEEE Life Member 3/16/2017 Agenda for today Refrigeration Cycle Chiller Types and Refrigerants Compressor Styles Chilled Water Pumping Systems
More informationNATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth
NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS Bernard Thonon Greth bernard.thonon@greth.fr Artificial or Natural Refrigerants? Performances COP Capacity Cost Safety Pressure, Temperature
More informationCFC ALTERNATIVES FOR REFRIGERATION : MORE THAN 2 YEARS OF FIELD TRIALS
CFC ALTERNATIVES FOR REFRIGERATION : MORE THAN 2 YEARS OF FIELD TRIALS P. WEISS, M. BARREAU Elf Atochem S.A Centre d'application de Levallois (C.A.L) 95, rue Danton 92300 Levallois Perret, FRANCE G. ROLOTTI
More informationExhibition Hall 1. Fachprogramm. Technical Programme
Exhibition Hall 1 Fachprogramm Technical Programme Nuremberg (Germany), 15 th October, 2014 Page 1 Ammonia and Natural Refrigerants in Turkey Hüseyin M. Yüksel ISKID-AC&R Manufacturers Association, Turkey
More informationHFC-227ea FIRE SUPPRESSION SYSTEM
C C L L E E AA NN AA GG E E NN T T F F I I R R E E S S UU P P P P R R E E S S S S I I OO NN HFC-227ea THE MOST TRUSTED FIRE SUPPRESSION SYSTEM ON THE MARKET HFC-227ea The superior design features and exceptional
More informationAir Conditioning Repairs: Maintenance Required
Air Conditioning Repairs: Maintenance Required Who Am I? CAMT EPA + R-410A Certified HVAC EX Pro. Certified 11 Years On Site 11+ Years training Paul Rhodes National Maintenance and Safety Instructor NAAEI
More informationGo Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe. Over
Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe Go Beyond Cool With Danfoss, you get more than reliable solutions for cold rooms. Contractor-friendly products built with market leading
More informationAUTOFROST Technical Discussions
AUTOFROST Technical Discussions A/C in a Nutshell Here is a simple three minute course in automotive Air Conditioning. All it really boils down to is one evaporates (boils) a working fluid in the vicinity
More informationCOMPARATIVE PROPERTIES AND EFFICIENCY OF R-421A FOR RETROFIT USE TO REPLACE R-22
COMPARATIVE PROPERTIES AND EFFICIENCY OF R-421A FOR RETROFIT USE TO REPLACE R-22 2013.12.26 prepared by James M. Calm, P.E. Engineering Consultant 10887 Woodleaf Lane Great Falls, VA 22066-3003 USA for
More informationAlternatives to HCFC/HFC refrigerants for high ambient temperatures
Öko-Recherche Büro für Umweltforschung und -beratung GmbH Alternatives to HCFC/HFC refrigerants for high ambient temperatures Bastian Zeiger Shecco side event 36th OEWG 22.07.2015 Paris, France UNESCO
More informationAIRAH Victoria Refrigerants Update
AIRAH Victoria Refrigerants Update 20 th October 2014 Agenda R22 Phase down Legislation and options Interim replacements and considerations New HFO refrigerants Legislation as a driver for change New HFO
More informationPositively Innovative R32 R32. Instructions for Use and Handling
Positively Innovative R32 Refrigerants R32 Instructions for Use and Handling 2 Contents Foreword 4 1 Characteristics 5 1.1 Characteristics 5 1.2 Flammability 6 1.3 Saturated Vapor Pressure / Temperature
More informationEffectively Managing the Transition to Lower GWP Refrigerants
Effectively Managing the Transition to Lower GWP Refrigerants Karim Amrane a, * a Air-Conditioning, Heating, and Refrigeration Institute, 2111 Wilson Blvd. Suite 500, Arlington, VA, USA Abstract Environmental
More informationHVACR Refrigeration
Western Technical College 10601101 HVACR Refrigeration Course Outcome Summary Course Information Description Career Cluster Instructional Level Total Credits 4.00 Total Hours 108.00 This course is an introduction
More information