INSPECTION La Mansion CARRETERA A BARRA DE NAVIDAD 2292 KM 6.9. PUERTO VALLARTA. JAL INSPECTED BY

Size: px
Start display at page:

Download "INSPECTION La Mansion CARRETERA A BARRA DE NAVIDAD 2292 KM 6.9. PUERTO VALLARTA. JAL INSPECTED BY"

Transcription

1 INSPECTION La Mansion CARRETERA A BARRA DE NAVIDAD 2292 KM 6.9. PUERTO VALLARTA. JAL INSPECTED BY

2 PROPERTY INSPECTIONS Valle de Ticala #183, Valle Dorado, Bahia de Banderas, Nayarit Cell: SCOPE AND PURPOSE The scope of the inspection and report is a limited visual inspection of the general systems and components of the home to identify any system or component listed in the report which may be in need of immediate major repair at the time of the inspection. The inspection will be performed in compliance with generally accepted standards of practice. The scope of the inspection is limited to the items listed within the report pages. The inspector s ability to find defects is limited by inaccessible or any area which is not exposed to view, lack of information about the property and many other factors. The inspector is not required to walk on the roof. Roofs are inspected for visual condition, and signs of leaks. We do not guaranty roofs to be free of leaks. Pools are inspected for general condition. Pool leaks are not part of the inspection unless they are apparent from leaking piping. The inspection does not include any destructive testing or dismantling. Client agrees to assume all the risk for all conditions which are concealed from view at the time of the inspection. This is not an inspection to detect code compliance, safety, design or cosmetic deficiencies. The report that is issued is an opinion as to the condition of the home at the time of the inspection. This opinion is arrived at by the best technical methods available in the home inspection industry. It is still only an opinion. This is not a home warranty, guarantee, insurance policy or substitute real state transfer disclosures. Your inspector is a home inspection generalist and is nor acting as a licensed engineer or expert in any craft or trade. If your inspector recommends consulting other specialized experts, client must do so at client s expense. All items put in the check list of every chart are inspected for their proper function, poor installation, excessive wear and general state of repair, damage and deterioration. For your convenience, the following conventions were used in the report: NA NI C U R R E N T C O N D I T I O N NA: Not applicable NI: Not inspected OK: Functional/operational/serviceable D: Damaged I: Imperfections NL: Near end of lifespan M: Monitoring EV: Professional evaluation RP: Replace RE: Repair Y: Yes N: No C: Comment A D V I S E D A P P R O V E D

3 IN SUMMARY An inspection has been performed to the house La Mansion. The following conditions have been noted: In general, the house is in good physical condition. Currently the mechanical aspects of the house appear to be in working condition. However, some things need to be repaired and also some preventative maintenance needs to be done. Additional details about this items in the following check list. The house appears to be well built with no signs of structural damage or unusual cracks that might indicate a concern. With regards to the few cracks found, they mostly appear to be typical for concrete construction, and these cosmetic imperfections should not be worrisome. These cracks are not likely to represent structural defects. Also there are no signs that show foundation weakness. On the roof there is a proper waterproofing treatment which it is good condition. There is not evidence of major humidity problems found. There are a few spots of moisture found which they should not be a concern since they are not a major or excessive humidity problem. The damage areas can be treated. The tile floor throughout the house is properly glued. Most of the imperfections with finishings are cosmetic issues that appear commonly over time. All the appliances in the kitchen were checked out for proper installation. They are installed within the standards. The washer and dryer operate. The appliances in the kitchen are in serviceable condition, such as dishwasher, disposal, freezer, refrigerator, microwave, stove and hood The refrigerator is disconnected from the water supply. In the second kitchen (Casita), the freezer section is working but the refrigerator side is not working. The burners are near end lifespan. All the ceiling fans in the house are in good working condition. Windows and doors operate easily and latch properly. No broken paned glass. The hardware remains in good condition. Regarding the condition of wood in the house: Most of the wood components throughout the house is well-kept. No visible termite damage. Only a few components were found with minor deterioration. More details about the location of this issue in the following check list. The cabinetry in both kitchens is in good condition. The doors of the cabinets and drawers operate properly. Wooden doors and closets are in good condition. All the components in every bathroom like faucets, showerheads, toilets, sinks, tubs are in serviceable condition, properly installed, operate and drain properly. Adequate flow and pressure at all fixtures. A few issues were noted. For example, the aerators in all the sink faucets are missing. The pump was removed in one of the tubs, etc. Additional details about this items in the following check list. Upon the review of the mechanicals, the following was noted: Regarding the condition of the AC units; upon testing in the air conditioning mode, a normal temperature drop across the evaporators coils was observed. This suggests that the units are operating properly. It also appears the condensers, control devices in each room appear to be in good working condition. With the exception of the AC unit in the kitchen and breakfast room. The problem seems to be at the condensers. The air conditioning in the living dinning area is cooled by a typical central air conditioning system. The coil fans are operational. It also appears the condensers and the control devices appear to be in good working condition. Upon the review of the electrical installation, the following was noted: The electrical system works. The size of the electrical services is sufficient (220V). All visible wiring within the house is copper. This is a good quality electrical conductor. There is a grounding system. All switches and light fixtures that were tested operate satisfactorily. The electrical outlets are appropriately grounded. Recently the electrical system within the house was upgraded with a transformer that should reduce the power consumption.

4 No major issues were found with the plumbing. The water pressure is sufficient. The automatic hydroneumatic pump function properly. The water heaters are sufficient and in good serviceable condition. The water filter and purifier system is operational. The garden watering system is functioning. The control, the bypass valves and drippers appear to be working. The security system is not operable. The electrified wire has been removed. For more additional details, please refer to the details in the following check lists: With regards to the sewer system. Apparently there are no defects in drainage network functionality. No odors and other symptoms indicative of rupture or obstruction of the sanitation network. It was hard to access to inspect in detail the septic tank. However it was reported that the septic tank has regular maintenance every six months and is said to be in good service. The bathrooms in the sand-scaped terrace below the pool are plumbed to the septic tank and thus must be pumped uphill to the septic tank. At some point in time the bathrooms were remodeled and the submerged pumps were covered with tile restricting access to them for service or replacement. However, currently these extractor pumps appear to be in working order. The gas line installation is in good condition with no leaks found. The propane gas tank is fairly new. It was installed in It appears to be in very good condition. The pool appears to be in acceptable condition. However, there is a small leak under the infinity canal where water is seen to be seeping through. Also There is a noticeable leak in the wall at pool mechanical room where a rusting cable or metal rod perforates the wall. These types of small leaks are easily treated. The pool mechanicals have been inspected to ensure proper operation. The mechanical equipment and components appear to be in good working condition. The pool heaters are functioning however, only one of the thermostats is working, thus making it necessary to turn that heater on with the switch. Also, both pool heaters are located within the pool s mechanical room and they may function more productively if they are located outside.

5 EXTERIOR EX-01 1 EXTERIOR CODE COMPONENT NA NI EX-01 EX-02 EXTERIOR FINISHINGS ROOF EX-02 EX-01 EX-03 MAIN ENTRANCE EX-04 COURTYARD ENTRANCE EX-05 LATERAL ENTRANCE EX-06 WALL - FENCE EX-07 EXTERIOR LIGHTS EX-08 ELECTRICAL OUTLETS EX-09 DRAINS FLOORS EX-10 GARAGE EX-11 GARAGE DOOR OPENER EX-01 This crack is ordinary visual defect related to concrete construction, and are not likely to represent structural defects. EX-02 There is a proper waterproofing treatment which it is good condition. The garage door opener needs to be reviewed by a technician as it s failing to open properly. Presently, if you press EX-11 the open button, the motor intends to start and then stops right away. After pressing the button a second time it DOES open. EX-02 EX-11

6 DOWNSTAIRS MAIN ENTRANCE 2 DINING LIVING AREA DI-01 INTERIOR WALLS DI-02 DI-03 CEILING FLOOR HALL DI-04 DI-05 SLIDING GLASS DOOR - OPENER WINDOWS BRIDGE DI-06 DI-07 STAIRCASE BLINDS & CURTAINS DI-01 DI-08 DI-08 IRON SECURITY GRILLS DI-09 SWITCHES & LIGHTS DI-10 PLUGS & GROUNDING DI-11 CEILING FAN DI-12 POWDER ROOM DI-13 BAR DI-14 AC UNITS DI-01 This small cracks should not be worrisome. These small cracks are not of importance. DI-08 The are a few ceiling lights bulbs burnt out in the bridge's ceiling.

7 DOWNSTAIRS KI-09 KI-09 KI-13 3 KITCHEN CODE COMPONENT NA NI OBERVATIONS KI-01 INTERIOR WALLS KI-02 CEILING KI-03 KI-04 FLOOR DOOR KI-14 KI-20 KI-05 WINDOW KI-06 BLINDS AND CURTAINS KI-07 IRON SECURITY GRILLS KI-08 COUNTERTOP KI-09 CABINETRY KI-10 SWITCHES & LIGHTS KI-11 PLUGS & GROUNDING KI-12 CEILING FAN KI-13 APPLIANCES KI-14 HOOD KI-15 SINK KI-16 SINK FAUCET KI-17 WATER PRESURE KI-19 DRAINING/PLUMBING KI-20 AC UNIT Noticeable damage by rotting. The only wood board that has rotted is under the sink. Also the hinges shows minor KI-09 corrosion. KI-13 The stove, refrigerator and freezer are new items. The refrigerator is not connected to the water supply yet. KI-14 The light in the hood is out. KI-20 The AC unit is nor cooling. The problem appears to be in the comprossor-condenser (exterior unit). NA:NOT APPLICABLE - NI:NOT INSPECTED - OK:FUNCTIONAL/OPERATIONAL/SERVICEABLE - D:DAMAGED - I:IMPERFEECTION - NL:NEAR END OF

8 DOWNSTAIRS DI-11 3 BREAKFAST ROOM DI-01 INTERIOR WALLS DI-02 CEILING DI-03 FLOOR DI-04 GLASS DOOR DI-05 WINDOW DI-06 BLINDS & CURTAINS DI-07 IRON SECURITY GRILLS DI-08 SWITCHES & LIGHTS DI-09 PLUGS & GROUNDING DI-10 CEILING FAN DI-11 AC UNIT DI-11 The AC unit is nor cooling. The problem appears to be in the comprossor-condenser (exterior unit).

9 DOWNSTAIRS 4 CODE SB-01 SB-02 SB-03 SB-04 SB-05 SB-06 SB-07 SB-08 SB-10 SB-11 SUITE ROOM I (down stairs) INTERIOR WALLS CEILING FLOOR MAIN DOOR SLIDING GLASS DOOR BLINDS AND CURTAINS IRON SECURITY GRILLS SWITCHES & LIGHTS PLUGS & GROUNDING CEILING FAN CLOSSET SB-12 AC UNIT SB-13 TERRACE COMPONENT NA NI The electrical outlets on both sides of the bed have the wrong polarity.

10 DOWNSTAIRS SB-12 SB-12 5 SB-01 SB-02 SB-03 SB-04 SB-05 SB-06 SB-07 SB-08 SB-10 SB-11 SB-12 SB-13 SB-14 SB-15 SB-16 SB-17 SB-18 SB-19 SUITE'S BATHROOM (down stairs) INTERIOR WALLS CEILING FLOOR MAIN DOOR WINDOW BLINDS AND CURTAINS IRON SECURITY GRILLS VANITY TOP SINK SINK FAUCET TOILET BIDET SHOWER FLOOR SHOWER DOOR SHOWER FAUCET TUB TUB FAUCET AC UNIT SWITCHES & LIGHTS SB-20 PLUGS & GROUNDING SB-21 DRAINING/PLUMBING SB-16 SB-10 The aerator in both faucets are missing. SB-12 One of the handles in the bidet is loose. SB-16 The pump of the tub was removed.

11 UPSTAIRS 6 SB-01 SB-02 SB-03 SB-04 SB-05 SB-06 SB-07 SB-08 SB-10 SB-11 SB-12 SUITE ROOM II (upstairs) INTERIOR WALLS CEILING FLOOR MAIN DOOR SLIDING GLASS DOOR BLINDS AND CURTAINS IRON SECURITY GRILLS SWITCHES & LIGHTS PLUGS & GROUNDING CEILING FAN CLOSSET AC UNIT SB-13 TERRACE SB-14 RAILINGS OK All the components in this room appear to be in good condition. No issues were found.

12 UPSTAIRS 6 BATHROOM II SB-01 INTERIOR WALLS SB-02 CEILING SB-03 FLOOR SB-04 DOOR SB-05 WINDOW SB-06 BLINDS AND CURTAINS SB-07 IRON SECURITY GRILLS SB-08 VANITY TOP SINK SB-10 SINK FAUCET SB-11 TOILET SB-12 SHOWER FLOOR SB-13 SHOWER DOOR SB-14 SHOWER HEAD-FAUCET SB-15 TUB SB-16 TUB FAUCET SB-15 EXHAUST FAN SB-16 SWITCHES & LIGHTS SB-17 PLUGS & GROUNDING SB-18 DRAINING/PLUMBING SB-15 SB-14 The wood under the sink has received some water or moisture damage. Which is causing it to rot and deteriorate. SB-10 The aerator in both sink faucets is missing. Because a rubber gasket was removed from the overhead ceiling shower head, it s not usable. However the wall SB-14 shower head is functional. Three jets in the jacuzzi do not blow water. The botton to starts the jets in the jacuzzi is loose. The drain stopper and SB-15 the switch malfunction. SB-15 SB-15

13 UPSTAIRS 7 SB-01 SB-02 SB-03 SB-04 SB-05 SB-06 SB-07 SB-08 SB-10 SB-11 SB-12 INTERIOR WALLS CEILING FLOOR MAIN DOOR FOLDING GLASS DOOR BLINDS AND CURTAINS IRON SECURITY GRILLS SWITCHES & LIGHTS PLUGS & GROUNDING CEILING FAN CLOSSET AC UNIT SB-13 TERRACE SB-14 RAILINGS OK SUITE ROOM III (upstairs) All the components in this room appear to be in good condition. No issues were found. 8 BATHROOM III SB-01 INTERIOR WALLS SB-02 CEILING SB-03 FLOOR SB-04 MAIN DOOR SB-05 WINDOW SB-06 BLINDS AND CURTAINS SB-07 IRON SECURITY GRILLS SB-08 VANITY TOP SINK SB-10 SINK FAUCET SB-11 TOILET SB-12 SHOWER FLOOR SB-13 SHOWER DOOR SB-14 SHOWER FAUCET SB-15 TUB SB-16 TUB FAUCET SB-17 EXHAUST FAN SB-18 SWITCHES & LIGHTS SB-19 PLUGS & GROUNDING SB-20 DRAINING/PLUMBING SB-10 The aerator is missing in the sink faucet.

14 UPSTAIRS 9 SB-01 SB-02 SB-03 SB-04 SB-05 SB-06 SB-07 SB-08 SB-10 SB-11 SB-12 SB-14 SUITE ROOM IV (upstairs) INTERIOR WALLS CEILING FLOOR MAIN DOOR SLIDING GLASS DOOR CORRIDOR WINDOWS BLINDS AND CURTAINS IRON SECURITY GRILLS SWITCHES & LIGHTS PLUGS & GROUNDING CEILING FAN CLOSET AC UNIT SB-15 TERRACE SB-16 RAILINGS OK All the components in this room appear to be in good condition. No issues were found.

15 UPSTAIRS SB-13 SB BATHROOM IV SB-01 INTERIOR WALLS SB-02 CEILING SB-03 FLOOR SB-04 MAIN DOOR SB-05 WINDOW SB-06 BLINDS AND CURTAINS SB-07 IRON SECURITY GRILLS SB-08 VANITY TOP SINK SB-10 SINK FAUCET SB-11 TOILET SB-12 SHOWER FLOOR SB-13 SHOWER DOOR SB-14 SHOWER FAUCET SB-15 TUB SB-16 TUB FAUCET SB-15 EXHAUST FAN SB-16 SWITCHES & LIGHTS SB-17 PLUGS & GROUNDING SB-18 DRAINING/PLUMBING SB-17 SB-10 The aerator is missing in the sink faucet. The glass door installation in this shower needs to have adjustments made to the hinges as the glass door rubs SB-13 against the floor. SB-17 There is no current to the electrical outlet by the sink.

16 CASITA NA:NOT APPLICABLE - NI:NOT INSPECTED - OK:FUNCTIONAL/OPERATIONAL/SERVICEABLE - D:DAMAGED - I:IMPERFEECTION - NL:NEAR END OF KI CASITA - KITCHEN KI-01 INTERIOR WALLS KI-02 CEILING KI-03 FLOOR KI-04 MAIN DOOR KI-05 WINDOW KI-06 BLINDS AND CURTAINS KI-07 COUNTERTOP KI-08 CABINETRY KI-09 SWITCHES & LIGHTS KI-10 PLUGS & GROUNDING KI-11 CEILING FAN KI-12 APPLIANCES KI-13 HOOD KI-14 SINK KI-15 SINK FAUCET KI-16 WATER PRESURE KI-17 DRAINING/PLUMBING KI-18 DINING AREA KI-19 AC UNIT KI-20 LAUNDRY OBERVATIONS KI-12 KI-20 The automatic electric ignition of the stove does not function. Also the freezer section is working but the refrigerator KI-12 side is not working.

17 CASITA 12 CASITA BEDROOM SB-01 INTERIOR WALLS SB-02 CEILING SB-03 FLOOR SB-04 MAIN DOOR SB-05 WINDOW SB-06 BLINDS AND CURTAINS SB-07 IRON SECURITY GRILLS SB-08 SWITCHES & LIGHTS PLUGS & GROUNDING SB-10 CEILING FAN SB-11 CLOSET SB-12 AC UNIT SB-13 PATIO There is no current to the electrical outlets on the side of the closets.

18 CASITA 13 SB-01 SB-02 SB-03 SB-04 SB-05 SB-06 SB-07 SB-08 SB-10 SB-11 SB-12 SB-13 SB-14 SB-15 SB-16 SB-15 SB-16 CASITA BATHROOM INTERIOR WALLS CEILING FLOOR MAIN DOOR WINDOW BLINDS AND CURTAINS IRON SECURITY GRILLS VANITY TOP SINK SINK FAUCET TOILETS SHOWER FLOOR SHOWER DOOR SHOWER FAUCET TUB TUB FAUCET EXHAUST FAN SWITCHES & LIGHTS SB-17 PLUGS & GROUNDING SB-18 DRAINING/PLUMBING SB-10 SB-10 The drain in one of the sinks is sluggish. It needs to be unclogged. Also the drain stopper and switch are not operational in both sinks. SB-10 One of the shower handles is loose.

19 EXTERIOR TE-03 TE TE CODE TE-01 TE-02 TE-03 TE-04 TE-05 TE-06 TE-07 TE-08 TE-09 TE-10 TE-11 TE-12 TE-01 TE-03 TE-06 TE-09 TE-10 BACKYARD POOL JACUZZY POOL MECHANICALS POOL LIGHT SYSTEM MECHANICAL POOL ROOM EXTERIOR BATHROOMS GUEST BEDROOM GUEST BEDROOM AC UNIT GUEST BEDROOM S BATHROOM BBQ COMPONENT SWITCHES & LIGHTS PLUGS & GROUNDING NA NI 1There are a few areas in the pool lining where the glass Venetian tiles are coming loose. 2. There is a noticeable leak in the pool wall where a rusting cable or metal rod perforates the wall. The water is seeping from the wall at this location. 3.There is a small leak under the infinity canal where water is seen to be seeping through. These types of small leaks are easily treated. Both pool heaters are functioning however, only one of the thermostats is working, thus making it necessary to turn that heater on with the switch. Also, both pool heaters are located within the pool s mechanical room and they may function more productively if they are located outside. The bathrooms are plumbed to the septic tank and thus must be pumped uphill to the septic tank. At some point in time the bathrooms were remodeled and the submerged pumps were covered with tile restricting access to them for service or replacement. However, currently these extractor pumps appear to be in working order. 1. There is water staining in the drywalled drop ceiling in the bathroom. When it rains the water penetrates through the stairs of the lateral entrance to the house. 2. Also the electrical outlet by the sink in the bathroom is not One of the burners in the grill has enough corrosion to warrant replacement, as the flow of gas may be compromised. Recommend to replace thus burner. TE-01.2 TE-01.1 TE-10 TE-01.2 TE-01.3 MEN RESTROOM TE-06 TE-10 TE-06.1 TE-06.1 TE-09.2

20 MECHANICALS MS-02 MS MECHANICAL SUPPLIES MS-15 MS-22 CODE COMPONENT NA NI ELECTRICAL SYSTEM MS-01 ELECTRICAL POWER TRANSFORMER MS-02 MAIN BREAKER (3) MS-03 CIRCUIT BREAKER PANELS MS-04 PANEL LOCATION & ACCESSIBILITY MS-05 GROUNDING SYSTEM MS-06 MS-07 WIRING VOLTAGE 220V MS-18 MS-16 MS-22 AIR ING MS-08 ELECTRICAL SHUTOFF MS-09 CONDENSER LOCATION MS-10 CONDENSER OPERATION MS-11 COOLING OUTLETS/SPLITS MS-12 AC PLUMBING MS-13 CONTROL OPERATION PLUMBING MS-14 WATER TANK - CISTERN MS-15 WATER FILTER AND PURIFIER MS-16 PUMP SYSTEM MS-17 WATER PRESURE MS-18 WATER HEATERS (2) MS-20 MS-10 MS-19 GAS LINE - GAS TANK (2016) MS-20 GARDEN WATERING SYSTEM MS-21 SEWAGE SYSTEM - SEPTIC TANK MS-22 SECURITY SYSTEM MS-20 MS-10 The AC unit in the kitchen and breakfast room does not cool down. The problem seems to be at the condensers. MS-21 The septic tank has had regular maintenance every six months and is said to be in good service. MS-22 The security system is not operable. The electrified wire has been removed. A:NOT APPLICABLE - NI:NOT INSPECTED - OK:FUNCTIONAL/OPERATIONAL/SERVICEABLE - D:DAMAGED - I:IMPERFEECTION - NL:NEAR END F

Troy's Home Inspection Services LLC

Troy's Home Inspection Services LLC Cover Page Property Inspection Report 33706 Inspection prepared for: Cord King & Patricia King Real Estate Agent: Jane Freel - RE/MA Date of Inspection: 3/4/2017 Time: 8:30 Age of Home: 2008 Size: 3279

More information

Inside Out Home Inspections

Inside Out Home Inspections Cover Page Inside Out Home Inspections Property Inspection Report Inspection prepared for: John Doe & Jane Doe Date of Inspection: 5/10/2014 Inspector: Lucas Sargent PO Box 514, Tioga, PA 16946 Phone:

More information

Jeff Brown Inspections

Jeff Brown Inspections Cover Page Jeff Brown Inspections Property Inspection Report Vegas NV, 89145 Inspection prepared for: Jim Shen Agent: Lauren Paris - Resolution Realty Inspection Date: 6/13/2013 Time: 10:00 Age: 26 years

More information

FAIRA TRANSPARENCY REPORTS th Ave NE B-3, Kenmore, WA March 28 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave NE B-3, Kenmore, WA March 28 th, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 17817 80th Ave NE B-3, Kenmore,

More information

PROPERTY REINSPECTION REPORT

PROPERTY REINSPECTION REPORT PROPERTY REINSPECTION REPORT Prepared For: Andrew Xia Address: 1078 Great Meadow Dr. Allen, TX 75013 By: Robert Taylor, TREC license # 3619 Date: 10/27/2014 The Three Page Visual Contract Agreement previously

More information

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM SUMMARY 1234 Main St.Severn 21144 Buyer Name 07/18/2018 9:00AM Henry Toman MD License 32391 1st American Home Inspection, LLC 443-685-4062 henrytoman61@gmail.com The summary is meant to organize the defects

More information

1710 ANYWHERE DRIVE, MONTGOMERY, AL 36109

1710 ANYWHERE DRIVE, MONTGOMERY, AL 36109 1710 ANYWHERE DRIVE, MONTGOMERY, AL 36109 INFRARED VIEW OF HOME Attention: Mr. John Smith SUBJECT PROPERTY The following inspection of a property located at 1710 Anywhere Drive, Montgomery, AL 36109, was

More information

Axiom Property Inspections

Axiom Property Inspections Cover Page Axiom Property Inspections Property Inspection Report 868 Wally Avenue, Henderson NV, 89178 Inspection prepared for: John Doe Agent: David Lawson - Axiom Inspection Date: 8/12/2010 Time: 2:30

More information

Canadian Property Inspections

Canadian Property Inspections Cover Page Canadian Property Inspections Home Inspection Report L9Z-1K4 Inspection prepared for: K.C. Pitman Date of Inspection: 3/6/2017 Time: 3pm Age of Home: 42 Size: 500-1000 Weather: Cloudy, cool.

More information

Steve Ramsey Home Inspections

Steve Ramsey Home Inspections Steve Ramsey Home Inspections I. STRUCTURAL SYSTEMS X A. Foundations Type of Foundation(s): Slab Foundation There is evidence of some foundation movement. Excessive caulk around windows, mortar and brick

More information

Inspection Report. Prepared for: Tonia Mann. Property Address: 402 Leslie Court McDonough, GA Date: March 07, 2013

Inspection Report. Prepared for: Tonia Mann. Property Address: 402 Leslie Court McDonough, GA Date: March 07, 2013 Inspection Report Prepared for: Tonia Mann Property Address: 402 Leslie Court McDonough, GA 30253 Date: March 07, 2013 Inspector: Charles Mann Edifice Inspections, Inc. (770) 594-2222 www.edificeinspections.com

More information

FAIRA TRANSPARENCY REPORTS nd Ave S, E-2, SeaTac, WA 98198

FAIRA TRANSPARENCY REPORTS nd Ave S, E-2, SeaTac, WA 98198 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 98198 Thank you for your interest in this Faira Certified home. We have coordinated the efforts

More information

Pre-Drywall Property Inspection

Pre-Drywall Property Inspection Pre-Drywall Property Inspection Information Date: 1/20/2014 Weather: Clear Sky Time: 8:15 am Buyers: Hans Nirmal Property Address: 2563 Forest Breeze Drive City: Frisco Realty Company: Associate: Mike

More information

DESIGNER KITCHEN WITH PREMIUM APPLIANCES 1407 & 1409 Military Trail Features & Finishes 1. Open concept kitchen with NEFF designer cabinetry and Caesa

DESIGNER KITCHEN WITH PREMIUM APPLIANCES 1407 & 1409 Military Trail Features & Finishes 1. Open concept kitchen with NEFF designer cabinetry and Caesa DESIGNER KITCHEN WITH PREMIUM APPLIANCES 1407 & 1409 Military Trail Features & Finishes 1. Open concept kitchen with NEFF designer cabinetry and Caesarstone countertop. 2. 4 x 16 ceramic tile backsplash.

More information

FAIRA TRANSPARENCY REPORTS. November 21, 2016

FAIRA TRANSPARENCY REPORTS. November 21, 2016 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 7307 22 nd Ave NW, Seattle, WA

More information

Terry Building Inspection report summary with all items addressed or explained in red

Terry Building Inspection report summary with all items addressed or explained in red Terry Building Inspection report summary with all items addressed or explained in red Health & Safety Summary The following are health and safety concerns. Recommend all evaluations and repairs / corrections

More information

I. STRUCTURAL SYSTEMS

I. STRUCTURAL SYSTEMS I. STRUCTURAL SYSTEMS A. Foundations Type of Foundation(s): Pier & Beam - Crawlspace Opinion: All exposed areas of the foundation were examined visually. Examination of the foundation was limited to photographs

More information

Asurity 1. Property Inspection Report S Gurd Rd., Hastings, MI Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski -

Asurity 1. Property Inspection Report S Gurd Rd., Hastings, MI Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski - Cover Page Property Inspection Report Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski - Date of Inspection: 3/28/2017 Time: 2:00 Age of Home: Built 1999 Size: 2015 Weather: 50 Overcast.

More information

FAIRA TRANSPARENCY REPORTS. February 28 th, 2018

FAIRA TRANSPARENCY REPORTS. February 28 th, 2018 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 5650 24 th Ave NW, #407, Seattle, WA 98107 February 28 th, 2018 Thank you for your interest

More information

FAIRA TRANSPARENCY REPORTS S 236th St, 10-5, Kent, WA 98032

FAIRA TRANSPARENCY REPORTS S 236th St, 10-5, Kent, WA 98032 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 5427 S 236th St, 10-5, Kent, WA 98032 Thank you for your interest in this Faira Certified

More information

This Report Was Prepared For: Property Address Inspected:

This Report Was Prepared For: Property Address Inspected: This Report Was Prepared For: Jane Do (to protect the identity and privacy of our clients) Property Address Inspected: 321 Sample Dr Example Report, FL 32828 Date: August 11, 2115 File # H50855255 The

More information

MAINTENANCE STANDARD LABOR CHARGE ESTIMATE AMOUNTS

MAINTENANCE STANDARD LABOR CHARGE ESTIMATE AMOUNTS Date Created: 06/24/2009 Date Approved: 10/23/2013 Resolution #2013-25 Printed copies are for reference only. Please refer to the electronic copy for the latest version. Policy: Maintenance Standard Labor

More information

Extra Mile Inspection, Inc.

Extra Mile Inspection, Inc. Cover Page Property Inspection Report Inspection prepared for: Jerry and Lynne Richardson Real Estate Agent: Polly Richardson - BHKR Lake Forest Date of Inspection: 3/13/2017 Time: 12 pm Age of Home: built

More information

FAIRA TRANSPARENCY REPORTS Alaskan Way, 514, Seattle, WA 98101

FAIRA TRANSPARENCY REPORTS Alaskan Way, 514, Seattle, WA 98101 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 1900 Alaskan Way, 514, Seattle, WA 98101 Thank you for your interest in this Faira Certified

More information

MHI Services Inc. Property Inspection Report

MHI Services Inc. Property Inspection Report Cover Page MHI Services Inc. Property Inspection Report 333 Some place Ave, Some Place OR, 970245 Inspection prepared for: SAMPLE REPORT & SAMPLE REPORT Inspection Date: 3/29/2009 Time: 8AM Age: 9 YEARS

More information

Make Ready Estimate. Total Tenant Charges $0

Make Ready Estimate. Total Tenant Charges $0 Tenant Charges Interior clean flat rate 0 $0 Pricing: $165-$275 Clean carpets flat rate 0 $0 Replace smoke alarm batteries $7 each 0 $0 Replace light bulbs $8 bulb 0 $0 Replace blinds $35 each 0 $0 Trash

More information

Patriot Home Inspections

Patriot Home Inspections Patriot Home Inspections 898 Whispering Pines Rd Johnsonville, SC 29555 (843) 386-9100 patriothomeinspections.com info@patriothomeinspections.com Inspected By: Hubert Miles Jr, RBI 2556 Condo Inspection

More information

FAIRA TRANSPARENCY REPORTS Hazel Loop SE, #D, Auburn, WA 98092

FAIRA TRANSPARENCY REPORTS Hazel Loop SE, #D, Auburn, WA 98092 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 6137 Hazel Loop SE, #D, Auburn, WA 98092 Thank you for your interest in this Faira Certified

More information

Move In Report. Report Information

Move In Report. Report Information 1 of 18 7/29/2009 1:54 PM Move In Report Provided By: WalkThruInspections.Com Report Information Tenants Name(s) John Jones Landlords Name Jill Smith Property Address 5552 SW 27th Place Palm Beach, FL

More information

Inspector Gadget Homes

Inspector Gadget Homes Cover Page Inspector Gadget Homes Property Inspection Report 34105 Inspection prepared for: Mike Cranley Date of Inspection: 3/20/2017 Time: 5:30pm Age of Home: 25 yrs old Size: 3,039 sq ft Weather: Sunny

More information

Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc

Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc Inspection Report 1 Inspection Way Orlando, FL 32825 Prepared for: Wanda Figueroa Prepared by: Page 1 of 25 Needs Service Summary This summary is not the entire report. The complete report may include

More information

1921 River Birch Dr., Shawnee, OK Inspection prepared for: Vicki Jager Date of Inspection: 7/27/2015 Time: 8am Weather: Sunny

1921 River Birch Dr., Shawnee, OK Inspection prepared for: Vicki Jager Date of Inspection: 7/27/2015 Time: 8am Weather: Sunny Cover Page 74804 Inspection prepared for: Vicki Jager Date of Inspection: 7/27/2015 Time: 8am Weather: Sunny Inspector: John Crouch License #70001257 Newalla, OK 74857 Phone: 4054815032 Email: john@goodlivinghomes.com

More information

FAIRA TRANSPARENCY REPORTS. March 14 th, 2017

FAIRA TRANSPARENCY REPORTS. March 14 th, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 4106 38 th Ave SW, Seattle, WA

More information

Bayshore House Inspections LLC

Bayshore House Inspections LLC Cover Page Bayshore House Inspections LLC Property Inspection Report 32963 Inspection prepared for: Ron Rosenthal Date of Inspection: 3/23/2017 Time: 10:30am Age of Home: 1950 Size: 3284 Weather: Clear

More information

FAIRA TRANSPARENCY REPORTS Greenwood Ave N, N304, Seattle, WA March 21, 2018

FAIRA TRANSPARENCY REPORTS Greenwood Ave N, N304, Seattle, WA March 21, 2018 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 8760 Greenwood Ave N, N304, Seattle, WA 98103 March 21, 2018 Thank you for your interest

More information

FAIRA TRANSPARENCY REPORTS th Dr NE, Marysville, WA June 14 th, 2017

FAIRA TRANSPARENCY REPORTS th Dr NE, Marysville, WA June 14 th, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 98270 June 14 th, 2017 We have

More information

FAIRA TRANSPARENCY REPORTS NE 182nd St, C101, Kenmore, WA 98028

FAIRA TRANSPARENCY REPORTS NE 182nd St, C101, Kenmore, WA 98028 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 6700 NE 182nd St, C101, Kenmore,

More information

FAIRA TRANSPARENCY REPORTS. 76 Cedar ST, Unit 505, Seattle, WA May 27, 2016

FAIRA TRANSPARENCY REPORTS. 76 Cedar ST, Unit 505, Seattle, WA May 27, 2016 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 76 Cedar ST, Unit 505, Seattle, WA 98121 May 27, 2016 Thank you for your interest in this

More information

FAIRA TRANSPARENCY REPORTS NE 117th Pl, #F8, Kirkland, WA 98034

FAIRA TRANSPARENCY REPORTS NE 117th Pl, #F8, Kirkland, WA 98034 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 12527 NE 117th Pl, #F8, Kirkland, WA 98034 Thank you for your interest in this Faira Certified

More information

Hearth and Homes Inspections, llc

Hearth and Homes Inspections, llc Cover Page Property Inspection Report 44092 Inspection prepared for: Ember Griffith Real Estate Agent: Samantha Elly - Keller Williams Date of Inspection: 3/4/2017 Time: 10:00 AM Age of Home: 63 Years

More information

RW West Consultants. Property Inspection Report NE 199th St, Kenmore, WA Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: -

RW West Consultants. Property Inspection Report NE 199th St, Kenmore, WA Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: - Cover Page RW West Consultants Property Inspection Report 98028 Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: - Date of Inspection: 5/26/2017 Time: 9:00 AM Age of Home: 2012 Size: 2480

More information

FAIRA TRANSPARENCY REPORTS. November 21, 2016

FAIRA TRANSPARENCY REPORTS. November 21, 2016 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 32712 SE 43 rd St., Fall City,

More information

MOVE-IN / MOVE-OUT CONDITION

MOVE-IN / MOVE-OUT CONDITION MOVE-IN / MOVE-OUT CONDITION REAL SOLUTIONS. REALTOR SUCCESS The pre-printed portion of this form has been drafted by the Arizona Association of REALTORS. Any change in the pre-printed language of this

More information

Amendment to the Inspection Report

Amendment to the Inspection Report Amendment to the Inspection Report Page 14 Item: 5 Toilet A loose toilet. This can indicate damage to the sub-flooring beneath the fixture and floor covering. This condition is not visible or fully accessible

More information

The Salvation Army Southern Territory OFFICERS QUARTERS PROPERTY INSPECTION FORM

The Salvation Army Southern Territory OFFICERS QUARTERS PROPERTY INSPECTION FORM The Salvation Army Southern Territory OFFICERS QUARTERS PROPERTY INSPECTION FORM Property Address: Age of Quarters: Years Date of Inspection: INSPECTION TEAM: Names: Profession/Position (i.e. Board Member,

More information

RW West Consultants. Property Inspection Report

RW West Consultants. Property Inspection Report Cover Page RW West Consultants Property Inspection Report 98122 Inspection prepared for: Faira Date of Inspection: 4/27/2017 Time: 9:00 AM Age of Home: 1992 Size: 3000 Weather: Cloudy 45 degrees Order

More information

FAIRA TRANSPARENCY REPORTS Stone Ave N, #205, Seattle, WA 98133

FAIRA TRANSPARENCY REPORTS Stone Ave N, #205, Seattle, WA 98133 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 11550 Stone Ave N, #205, Seattle, WA 98133 Thank you for your interest in this Faira Certified

More information

HOME INSPECTION REPORT

HOME INSPECTION REPORT HOME INSPECTION REPORT 75-5748 Alahou Street 2F Report Prepared For: Barbara Little Report Prepared By: Warren d'aquin Page 2 of 23 TABLE OF CONTENTS TABLE of CONTENTS... 2 SUMMARY REPORT... 3 GENERAL

More information

FAIRA TRANSPARENCY REPORTS. January 6 th, 2017

FAIRA TRANSPARENCY REPORTS. January 6 th, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 3834 175 th Ave NE, A309, Redmond,

More information

Scope of Work - Single Family, Oceanside, CA

Scope of Work - Single Family, Oceanside, CA Scope of Work - Single Family, Oceanside, CA Project Introduction and Overview 2,154 Sq/ft home with 2 levels built in 1970. This home has 4 bedroom 2.5 baths with a pool and located in Oceanside. Great

More information

Property Description: (1) level condominium in a multi-story building Property age/ size: Built 2006, 1,137 s.f. per listing Occupancy Status: Vacant

Property Description: (1) level condominium in a multi-story building Property age/ size: Built 2006, 1,137 s.f. per listing Occupancy Status: Vacant (425) 652-6515 Kevin@Hergert.com Wa. Home Inspector 619 WSDA Inspector 79988 WSDA Control # 1336AQ-012 Client: Address: Property Description: (1) level condominium in a multi-story building Property age/

More information

FAIRA TRANSPARENCY REPORTS W Manor Pl, #413, Seattle, WA August 25, 2017

FAIRA TRANSPARENCY REPORTS W Manor Pl, #413, Seattle, WA August 25, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 2510 W Manor Pl, #413, Seattle,

More information

Watson Home Inspection Services, LLC.

Watson Home Inspection Services, LLC. Cover Page Watson Home Inspection Services, LLC. Property Inspection Report 16466 Olalee Rd, Apple Valley Ca., 92307 Inspection prepared for: Jesse Owens & Zona Owens Agent: Ofir Andrews - Hamilton Landon

More information

Inspection Checklist. Kitchen

Inspection Checklist. Kitchen This checklist is used to document the condition of your home at the time you move-in. This same checklist will be used to compare the move-in condition to when and if you move out. It s part of your lease.

More information

FAIRA TRANSPARENCY REPORTS th Ave SE, Renton, WA June 13 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave SE, Renton, WA June 13 th, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 98058 June 13 th, 2017 We have

More information

FAIRA TRANSPARENCY REPORTS Country Club Dr, B-203, Mill Creek, WA April 5 th, 2017

FAIRA TRANSPARENCY REPORTS Country Club Dr, B-203, Mill Creek, WA April 5 th, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 15433 Country Club Dr, B-203, Mill Creek, WA 98012 Thank you for your interest in this Faira

More information

CHARGES FOR REPAIRS AND SERVICES Please note prices are subject to change without prior notice.

CHARGES FOR REPAIRS AND SERVICES Please note prices are subject to change without prior notice. CHARGES FOR REPAIRS AND SERVICES Please note prices are subject to change without prior notice. ITEM DESCRIPTION UNIT COST Comments FLOORING Floor Tile Remove and replace with similar (as available) sf

More information

Savannah Station Price List

Savannah Station Price List Savannah Station Price List Standard ONLY 3 Standard Lots Left Lot 105* Shenandoah (1301) $153,500.00 Lot 72** Georgian (1409) $164,900.00 Lot 82*** Georgian (1409) $166,900.00 Premium Shenandoah (1301)

More information

Paramount Property Mgmt & Realty LLC MOVE-IN / MOVE-OUT CONDITION CHECKLIST

Paramount Property Mgmt & Realty LLC MOVE-IN / MOVE-OUT CONDITION CHECKLIST Paramount Property Mgmt & Realty LLC MOVE-IN / MOVE-OUT CONDITION CHECKLIST REAL SOLUTIONS. REALTOR SUCCESS The pre-printed portion of this form has been drafted by the Arizona Association of REALTORS.

More information

FAIRA TRANSPARENCY REPORTS th Ave N, Edmonds, WA January 19 th, 2018

FAIRA TRANSPARENCY REPORTS th Ave N, Edmonds, WA January 19 th, 2018 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 98020 January 19 th, 2018 We have

More information

The Ultimate Home Maintenance Schedule

The Ultimate Home Maintenance Schedule The Ultimate Home Maintenance Schedule On-Going Quarterly Maintenance Schedule Check interior and exterior faucets for leaks. Clean aerators. Replace washers if Clean with baking soda. Pour water down

More information

TERRACE VIEW APARTMENTS

TERRACE VIEW APARTMENTS TERRACE VIEW APARTMENTS HUNT CLUB ROAD BLACKSBURG, VIRGINIA APARTMENT FINISHES AND UPGRADES UNIT TYPE 3A x 1.5 Phase 5-8 Unit Number 4 Units Total 1) 6600F 2) 6800K 3) 7600G 4) 7900H SCOPE OF WORK A-108-E

More information

RENTAL PROPERTY INVENTORY AND CONDITION FORM

RENTAL PROPERTY INVENTORY AND CONDITION FORM RENTAL PROPERTY INVENTORY AND CONDITION FORM INVENTORY AND CONDITION FORM CONCERNING THE PROPERTY AT: Complete the move-in section of this form and return it to your Landlord within 3 days. All items are

More information

FAIRA TRANSPARENCY REPORTS th St SE, #13A, Auburn, WA January 25, 2018

FAIRA TRANSPARENCY REPORTS th St SE, #13A, Auburn, WA January 25, 2018 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 418 17th St SE, #13A, Auburn, WA

More information

SUMMARY th Ave SW, Minot ND Cory Gibbons August 17, 2018

SUMMARY th Ave SW, Minot ND Cory Gibbons August 17, 2018 SUMMARY 1300 34th Ave SW, Minot ND 58701 Cory Gibbons August 17, 2018 Shane Hillman InterNACHI Certified... Magic City Inspections, LLC 701.720.9260 shane@minotinspections.com 4.4.1 Doorbell DOORBELL (INOPERABLE)

More information

American Property Inspectors of Northwest Florida, Inc.

American Property Inspectors of Northwest Florida, Inc. American Property Inspectors of Northwest Florida, Inc. Home Inspection For the Property Located At: 1111 Old School House Rd Somewhere, FL Report Prepared For: Customers Name 327A Racetrack Rd NW, Ft

More information

FAIRA TRANSPARENCY REPORTS SE 41st Ln, E203, Bellevue, WA April 7 th, 2017

FAIRA TRANSPARENCY REPORTS SE 41st Ln, E203, Bellevue, WA April 7 th, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 12834 SE 41st Ln, E203, Bellevue,

More information

Inspection Report. Mr. Happy Homeowner. Property Address: Focal Point Home Inspection Ltd.

Inspection Report. Mr. Happy Homeowner. Property Address: Focal Point Home Inspection Ltd. Page 1 of 19 Inspection Report Mr. Happy Property Address: Joseph Poelsterl 450.010220 6334 W. Grace st Chicago Illinois 60634 1-773-454-6700 Page 2 of 19 Table of Contents Cover Page Table of Contents

More information

John Sample. Property Address: 123 Main St. Alpharetta GA Inspector: Jason David. Residential Inspector of America, Inc.

John Sample. Property Address: 123 Main St. Alpharetta GA Inspector: Jason David. Residential Inspector of America, Inc. John Sample Property Address: 123 Main St. Alpharetta GA 30022 Inspector: Jason David Residential Inspector of America, Inc. 3276 Buford Drive, Ste. 104-306 Buford, GA 30519 770.476.4963 ICC Certified

More information

FAIRA TRANSPARENCY REPORTS Bothell Everett Hwy, D304, Bothell, WA February 6, 2018

FAIRA TRANSPARENCY REPORTS Bothell Everett Hwy, D304, Bothell, WA February 6, 2018 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 18930 Bothell Everett Hwy, D304, Bothell, WA 98012 Thank you for your interest in this Faira

More information

Scope of Work - Single Family, Carlsbad, CA

Scope of Work - Single Family, Carlsbad, CA Scope of Work - Single Family, Carlsbad, CA Project Introduction and Overview Spectacular renovation near the village in Carlsbad. This 3 BR/ 2.5 BA 1,612 square foot house is located just off of Tamarack

More information

TERRACE VIEW APARTMENTS

TERRACE VIEW APARTMENTS TERRACE VIEW APARTMENTS HUNT CLUB ROAD BLACKSBURG, VIRGINIA APARTMENT FINISHES AND UPGRADES UNIT TYPE 2 x 1.5 Phase 5-8 Unit Number 11 Units Total 1) 4200C 2) 4200K 3) 4500D 4) 4500G 5) 4500H 6) 5400A

More information

Inspection Report. Cheri Maisonneuve. Property Address: 103 Dogleg Dr Moultrie GA. Welcome Home! Premier Home Inspections of Valdosta, LLC

Inspection Report. Cheri Maisonneuve. Property Address: 103 Dogleg Dr Moultrie GA. Welcome Home! Premier Home Inspections of Valdosta, LLC Inspection Report Cheri Property Address: 103 Dogleg Dr Moultrie GA Welcome Home! Shea Wynn 1709A Gornto Rd, UPS #131 Valdosta, GA 31601 229-292-4694 Table of Contents Cover Page...1 Table of Contents...2

More information

Inspection Summary. Canyon State Property Inspections 3114 South 98th Street Mesa, AZ (480)

Inspection Summary. Canyon State Property Inspections 3114 South 98th Street Mesa, AZ (480) Inspection Summary Canyon State Property Inspections 3114 South 98th Street Mesa, AZ 85212 (480) 699-1651 www.canyonstateinspections.com ELECTRIC Main Electrical Panel Circuits Safety Concern The electrical

More information

Scope of Work - Single Family, Escondido, CA

Scope of Work - Single Family, Escondido, CA Scope of Work - Single Family, Escondido, CA Project Introduction and Overview Description 2008 square foot 4 bedroom, 3 bath contemporary styled home built in 1995 in the Emerald Heights neighborhood

More information

FAIRA TRANSPARENCY REPORTS th St SW, 301, Lynnwood, WA May 31 st, 2017

FAIRA TRANSPARENCY REPORTS th St SW, 301, Lynnwood, WA May 31 st, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 5801 200th St SW, 301, Lynnwood,

More information

FAIRA TRANSPARENCY REPORTS S 259th St, Des Moines, WA October 2, 2017

FAIRA TRANSPARENCY REPORTS S 259th St, Des Moines, WA October 2, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 98198 October 2, 2017 We have coordinated

More information

OWNER MAKE READY ADDENDUM

OWNER MAKE READY ADDENDUM Smart Pad Property Management is known for attractive and well kept homes. The cleaner and better kept the home is the quicker we can get it rented under quality terms. We will take pictures and thoroughly

More information

Inspection Report 123 My Street Midland, GA

Inspection Report 123 My Street Midland, GA Buying, Selling or Building Your Home Inspection Company ROFESSIONAL INSPECTION SERVICES, LLC P.O. Box 9774 Columbus, GA 31908 706-565-0333 1-866-298-4251 Inspection Report 123 My Street Midland, GA This

More information

FAIRA TRANSPARENCY REPORTS S 272nd St, #39, Kent, WA September 1 st, 2017

FAIRA TRANSPARENCY REPORTS S 272nd St, #39, Kent, WA September 1 st, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 2609 S 272nd St, #39, Kent, WA 98032 Thank you for your interest in this Faira Certified

More information

Bay Wide Commercial and Home Inspection Thackeray Avenue/ Mail address Hayward, Calif TH AVENUE SAN LEANDRO, CALIFORNIA

Bay Wide Commercial and Home Inspection Thackeray Avenue/ Mail address Hayward, Calif TH AVENUE SAN LEANDRO, CALIFORNIA 27966 Thackeray Avenue/ Mail address Hayward, Calif. 94544 2011 150TH AVENUE SAN LEANDRO, CALIFORNIA 21:12 August 07, 2015 Page 1 of 11 Table of Contents Definitions 2 General Information 2 Lots and Grounds

More information

TERRACE VIEW APARTMENTS

TERRACE VIEW APARTMENTS TERRACE VIEW APARTMENTS HUNT CLUB ROAD BLACKSBURG, VIRGINIA APARTMENT FINISHES AND UPGRADES UNIT TYPE 1x1.5 TH Phase 4 Unit Number 14 Units Total 1) 24B 2) 26B 3) 30F 4) 31B 5) 32B 6) 33B 7) 36B 8) 36H

More information

FAIRA TRANSPARENCY REPORTS Fairview Ave E, #304, Seattle, WA June 7 th, 2017

FAIRA TRANSPARENCY REPORTS Fairview Ave E, #304, Seattle, WA June 7 th, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 2301 Fairview Ave E, #304, Seattle,

More information

TERRACE VIEW APARTMENTS

TERRACE VIEW APARTMENTS TERRACE VIEW APARTMENTS HUNT CLUB ROAD BLACKSBURG, VIRGINIA APARTMENT FINISHES AND UPGRADES UNIT TYPE 4 x 2.5 Phase 5-8 Unit Number 1 Unit Total 1) 7400B SCOPE OF WORK A-112-C 4 Bedroom 2 Bath 2 Half

More information

FAIRA TRANSPARENCY REPORTS. 405 SW 346th Pl, Federal Way, WA Nov 09th, 2015

FAIRA TRANSPARENCY REPORTS. 405 SW 346th Pl, Federal Way, WA Nov 09th, 2015 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 98023 Nov 09th, 2015 We have coordinated

More information

146 Westrose Avenue

146 Westrose Avenue 146 Westrose Avenue WWW.146WESTROSE.COM www.christensenteam.ca Welcome Home Outstanding Custom Home in the Kingsway. Nestled on a cul-de-sac in The Kingsway, this stunning home provides over 3000 square

More information

FAIRA TRANSPARENCY REPORTS Brighton Pl, Mukilteo, WA 98275

FAIRA TRANSPARENCY REPORTS Brighton Pl, Mukilteo, WA 98275 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 98275 Thank you for your interest in this Faira Certified home. We have coordinated the efforts

More information

TERRACE VIEW APARTMENTS

TERRACE VIEW APARTMENTS TERRACE VIEW APARTMENTS HUNT CLUB ROAD BLACKSBURG, VIRGINIA APARTMENT FINISHES AND UPGRADES UNIT TYPE 4 x 2 Phase 5-8 Unit Number 1 Unit Total 1) 4300G SCOPE OF WORK A-111-B 4 Bedroom 2 Bath RENOVATION

More information

FEATURES PLEASANT PROSPECT RD. BOWIE, MD 20721

FEATURES PLEASANT PROSPECT RD. BOWIE, MD 20721 Originally built in 1986. Structure was demolished and new house was rebuilt in 1996 Choice premium lot on 8 th Hole Double driveways to include circular with custom landscaping Custom Grand front entry

More information

TERRACE VIEW APARTMENTS

TERRACE VIEW APARTMENTS TERRACE VIEW APARTMENTS HUNT CLUB ROAD BLACKSBURG, VIRGINIA APARTMENT FINISHES AND UPGRADES UNIT TYPE 2A x 1 Phase 5-8 Unit Number 13 Units Total 1) 4400C 2) 4400G 3) 4400K 4) 4900C 5) 5000C 6) 5100K 7)

More information

Montgomery County Land Bank PRE SALE INSPECTION REPORT

Montgomery County Land Bank PRE SALE INSPECTION REPORT Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH 45402 Address: 1517 PRINCETON Pre-Sale Number: City: DAYTON Location: Inspector: Sue Pratt Phone Number: PRE SALE INSPECTION REPORT

More information

Home Inspection Report

Home Inspection Report Home Inspection Report 3333 Main Street Mount Dora, FL 32757 Prepared for: Dave Penny Prepared by: PO Box 856 Mt. Dora, FL 32757 Tel 352 552 2136 davepenny@comcast.net Page 1 of 15 General Information

More information

Inspection Report. Prepared For: Joe Smith. Property Address: 1234 Slick Lane. #2 Chicago, IL. Inspectrum Inc.

Inspection Report. Prepared For: Joe Smith. Property Address: 1234 Slick Lane. #2 Chicago, IL. Inspectrum Inc. Page 1 of 22 Inspection Report Prepared For: Joe Smith Property Address: #2 Chicago, IL Inspectrum Inc. Julio Neira Inspectrum Inc Suite #227 3139 N Lincoln Ave. Chicago Il. 60657 Page 2 of 22 INVOICE

More information

450 Greywalls Lane Iron Station, North Carolina

450 Greywalls Lane Iron Station, North Carolina 450 Greywalls Lane Iron Station, North Carolina Main Floor Main Entry Foyer Grand Foyer with winding staircase leading to wrap-around upper foyer Karastan Wool carpet on center of stairs Picture frame

More information

15325 MASONWOOD DRIVE GAITHERSBURG, MARYLAND 20878

15325 MASONWOOD DRIVE GAITHERSBURG, MARYLAND 20878 15325 MASONWOOD DRIVE GAITHERSBURG, MARYLAND 20878 2 STORY ENTRY HALL FRONT EXTERIOR LIBRARY GREAT ROOM LIVING ROOM DINING ROOM KITCHEN BREAKFAST ROOM MASTER BEDROOM MASTER BATHROOM MAIN LEVEL EN SUITE

More information

Scope of Work - Single Family, Chula Vista, CA

Scope of Work - Single Family, Chula Vista, CA Scope of Work - Single Family, Chula Vista, CA Project Introduction and Overview Gorgeous renovation in Chula Vista. This 3 BR/ 2 BA 1,236 square foot house is located just minutes from the 805 with easy

More information

FAIRA TRANSPARENCY REPORTS SE Woody Creek Ln, Snoqualmie, WA October 12, 2017

FAIRA TRANSPARENCY REPORTS SE Woody Creek Ln, Snoqualmie, WA October 12, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 98065 Thank you for your interest in this Faira Certified home. October 12, 2017 We have

More information

631 Logan Avenue - Features & Finishes

631 Logan Avenue - Features & Finishes 631 Logan Avenue - Features & Finishes Main Floor Foyer Separated from Living Room Full light front door Living Room Casement window with 2 operating windows, west facing Dining Room 2 fixed windows &

More information

fieldwork report contains the Functional

fieldwork report contains the Functional December 6, 2010 Dear Bill and Ann, On October 2, 2010, Cities Inspection Service, Inc. completed a home inspection of the property located at 2344 Arbour Lane, St. Paul, Minnesota for you. Doug Hastings

More information

Additional Information 1626 Arapahoe Trail

Additional Information 1626 Arapahoe Trail Additional Information 1626 Arapahoe Trail The purpose of this document is to provide helpful information about this property and its amenities. It is not intended to be an all-inclusive list of every

More information