Technical Committee on Mining Facilities (MIN-AAA)

Size: px
Start display at page:

Download "Technical Committee on Mining Facilities (MIN-AAA)"

Transcription

1 Technical Committee on Mining Facilities (MIN-AAA) M E M O R A N D U M DATE: February 21, 2018 TO: FROM: Principal and Alternate Members of the Technical Committee on Mining Facilities Shawn Mahoney, Staff Liaison SUBJECT: AGENDA PACKAGE NFPA 120 & 122 First Draft Meeting (F2019) Enclosed is the agenda for the NFPA 120 & 122 First Draft meeting of the Technical Committee on Mining Facilities, which will be held on Tuesday, March 20 th through Wednesday, March 21 th, 2018 in San Antonio, TX. Please review the attached Public Inputs in advance, and if you have alternate suggestions, please come prepared with proposed language and respective substantiation. If you have any questions prior to the meeting, please do not hesitate to contact me at: Office: (617) smahoney@nfpa.org For administrative questions, please contact Jenny Depew at (617) I look forward to working with everyone.

2 Technical Committee on Mining Facilities (MIN-AAA) NFPA 120 & 122 First Draft Meeting (Fall 2019) Tuesday, March 20 to Wednesday, March 21, 2018 The Westin Riverwalk, San Antonio 420 W Market Street San Antonio, TX Call to Order 8:00 am CST (3/20) 2. Introductions and Attendance 3. Chairman Comments AGENDA Tuesday, March 20, Approval of Previous Meeting Minutes (Attached) 5. Staff Liaison Presentation on NFPA Revision Process and F2019 Cycle 6. Preparation of the First Draft Review Public Inputs (attached) Create First Revisions 7. Task Group Work 8. New Business Next Meeting 9. Adjournment 5:00 pm CST (3/20) and 5:00 pm CST (3/21) Please submit requests for additional agenda items to the chair and staff liaison at least seven days prior to the meeting.

3 Technical Committee on Mining Facilities (MIN-AAA) NFPA 120 & 122 First Draft Meeting (Fall 2019) Tuesday, March 20 to Wednesday, March 21, 2018 The Westin Riverwalk, San Antonio 420 W Market Street San Antonio, TX Key Dates for the Fall 2019 Revision Cycle Public Input Closing Date January 4, 2018 Final Date for First Draft Meeting June 14, 2018 Posting of Ballot by August 2, 2018 First Draft Ballot Due Date August 30, 2018 Posting of First Draft Report for Public Comment September 9, 2018 Public Comment Closing Date November 15, 2018 Final Date for Second Draft Meeting May 16, 2019 Posting of Ballot by June 27, 2019 Ballots due by July 25, 2019 Posting of Second Draft Report for NITMAM Review August 1, 2019 Closing Date for Notice of Intent to Make a Motion (NITMAM) August 29, 2019 Issuance of Consent Document (No NITMAMs) November 4, 2019 NFPA Annual Meeting June 14-18, 2020 Issuance of Document with NITMAM TBA Technical Committee deadlines are in bold.

4 Address List No Phone Mining Facilities 02/21/2018 Shawn Mahoney MIN-AAA Mario G. Orozco Chair Zurich Insurance 1721 Poplar Place Schaumburg, IL I 1/10/2002 MIN-AAA David G. Aden Principal State of Alaska Department of Public Safety Division of Fire & Life Safety 1979 Peger Road Fairbanks, AK E 3/1/2011 MIN-AAA Steven M. Behrens Principal Global Asset Protection Services, LLC 100 Constitution Plaza Hartford, CT I 11/2/2006 MIN-AAA Michael Breneman Principal Peabody Energy 701 Market Street St Louis, MO U 08/17/2017 MIN-AAA Dennis D. Brohmer Principal Tyco Fire Protection Products One Stanton Street Marinette, WI Alternate: Dennis M. Phillips M 4/17/1998 MIN-AAA Matthew J. Bujewski Principal MJB Risk Consulting 9650 Mill Hill Lane St. Louis, MO SE 4/1/1993 MIN-AAA John D. Campbell Principal Global Fire Protection Group, LLC 732 Spring Crest Court Fenton, MO Hidrosistemas Baja M 04/04/2017 MIN-AAA Joseph J. Chrobak, Sr. Principal William Penn Fire Company 23 Blue Ridge Drive Levittown, PA E 11/30/2016 MIN-AAA Jack Douglas Conaway Principal Arch Coal, Inc. One CityPlace Drive, Suite 300 St. Louis, MO Alternate: Eric Metheny U 3/4/2009 MIN-AAA Brian Corcoran Principal Wolverine Fire Protection 2910 S Highland Drive, Suite G Las Vegas, NV IM 04/08/2015 MIN-AAA Thomas A. Delorie, Jr. Principal Marsh Risk Consulting Six PPG Place, Suite 400 Pittsburgh, PA I 08/09/2012 MIN-AAA Nate Edmondson Principal Afex Fire Suppression Systems 5808 Lease Lane Raleigh, NC M 12/06/2017 MIN-AAA Rickard P. Hansen Principal Malmfaltens Brandkonsult Taljstensvagen 7 Nykoping, S Sweden SE 08/03/2016 MIN-AAA L. Harvey Kirk, III Principal US Department of Labor Mine Safety & Health Administration 1100 Wilson Blvd., Room 2446 Arlington, VA Alternate: Charles Barton E 3/15/2007 MIN-AAA 1

5 Address List No Phone Mining Facilities 02/21/2018 Shawn Mahoney MIN-AAA James M. Kohl IM 10/28/2008 Principal MIN-AAA Cintas Fire Protection 621B Industrial Park Road Carbondale, IL National Association of Fire Equipment Distributors Erick Mondragon Principal Swiss Reinsurance Company (Swiss Re) 1450 Brickell Avenue, Suite 1750 Miami, FL I 08/03/2016 MIN-AAA Larry J. Moore Principal FM Global Ranch Elsie Road Golden, CO Alternate: Scott C. Strickling I 1/1/1988 MIN-AAA Rob Rosovich Principal FireIce Inc Park Lane South, Suite 1 Jupiter, FL M 03/07/2013 MIN-AAA Michael Schmeida Principal Gypsum Association 3730 Sharon-Copley Road Medina, OH Alternate: Timothy Earl U 12/08/2015 MIN-AAA Steven A. Sheldon Principal Fisher Engineering, Inc East Southern Avenue Mesa, AZ SE 08/09/2012 MIN-AAA Robert D. Taylor Principal PRB Coal Users Group 4377 Sandra Kay Lane Newburgh, IN U 12/06/2017 MIN-AAA Spencer Thompson Principal North American Coal Nw 101 Road, Suite 19 Medley, FL U 08/17/2017 MIN-AAA William B. Till, Jr. Principal Bernie Till & Associates LLC 197 Till Hill Road Orangeburg, SC SE 12/08/2015 MIN-AAA Daniel P. Wake Principal Victaulic Company of America 4901 Kesslersville Road PO Box 31 Easton, PA National Fire Sprinkler Association Alternate: John L. Hulett M 08/11/2014 MIN-AAA Chris Yoder Principal Pillar Innovations 32 Corporate Drive Grantsville, MD Kendall A. Pate Voting Alternate Amerex Corporation 7595 Gadsden Highway PO Box 81 Trussville, AL M 03/07/2013 MIN-AAA M 8/9/2011 MIN-AAA Liming Yuan Principal National Institute for Occupational Safety & Health 626 Cochrans Mill Road Pittsburgh, PA National Institute for Occupational Safety & Health RT 08/03/2016 MIN-AAA 2

6 Address List No Phone Mining Facilities 02/21/2018 Shawn Mahoney MIN-AAA Charles Barton Alternate US Department of Labor Mine Safety & Health Administration 201 S. 12th Street Suite 401 Arlington, VA Principal: L. Harvey Kirk, III E 04/04/2017 MIN-AAA Timothy Earl Alternate GBH International 6862 Shallowford Way Portage, MI Gypsum Association Principal: Michael Schmeida U 08/17/2017 MIN-AAA John L. Hulett Alternate Western States Fire Protection Company 7020 South Tucson Way Centennial, CO National Fire Sprinkler Association Principal: Daniel P. Wake M 08/11/2014 MIN-AAA Eric Metheny Alternate Arch Coal Sentinel Complex Barbour County Highway Philippi, WV Principal: Jack Douglas Conaway U 10/23/2013 MIN-AAA Dennis M. Phillips Alternate Tyco Fire Protection Products 1700 Valleyview Drive Mount Juliet, TN Principal: Dennis D. Brohmer M 10/18/2011 MIN-AAA Scott C. Strickling Alternate FM Global Camino Las Carretas 9911 Lo Barnechea Santiago, Chile Principal: Larry J. Moore I 3/1/2011 MIN-AAA Shawn Mahoney Staff Liaison National Fire Protection Association One Batterymarch Park Quincy, MA /11/2017 MIN-AAA 3

7 MIN AAA Technical Committee on Mining Facilities Second Draft Meeting for NFPA 120 and 122 January 7 th and 8 th, 2014 Dallas, TX Members Present Alternate Present Matt Bujewski chair Yes David Aden Yes Steven M. Behrens Yes J. Emmett Bevins Yes Kendall A. Pate No Dennis Brohmer Yes phone Dennis Phillips No Jack Douglas Conaway No Eric Metheny yes Thomas A. Delorie Yes L. Harvey Kirk III Yes phone James Kohl Yes phone Jeff Krieger No Larry Moore No Scott Strickling Yes Mario Orozco No Rob Rosovich Yes phone Steven Sheldon Yes Alex Smith Yes phone Thomas Stilwell No Brent Sullivan Yes Bruce Watzman No Rick Wells No Robert Wessel No Michael Gardner No Chris Yoder Yes Bill Jolbert (guest) Yes Susan Bershad (NFPA) Yes 1.0 Meeting was called to order by the Chair, Matt Bujewski, at 8:30 am on January 7 th. 2.0 Those members present and those on the phone introduced themselves. 3.0 Susan Bershad gave a presentation on the new process, the schedule for the fall 2014 revision cycle and an overview of the current committee makeup. 4.0 The technical committee reviewed and acted on public comment on NFPA The technical committee reviewed and acted on committee member comments on the first draft ballot. Page 1 of 2

8 6.0 The technical committee reviewed the work completed by three task groups established at the first draft meeting. These were as follows: Mobile/Self propelled/portable Equipment Sprinklers NFPA 120 Sections and Task Force MCC Room Detection/Protection 7.0 The committee acted on the work of the mobile/self propelled task group and the 122 task group. This work was input as second revisions for both 120 and 122. Susan will create a draft of the work of the sprinkler task group as a word file with changes tracked. This will be distributed to the committee for review and also be distributed to a task group from the NFPA 13 Technical Committee for comment. Depending on the results of the NFPA 13 review, the committee may need to have a conference call to finalize the second revisions. Susan and Matt will schedule this meeting, if needed, once comments are received. This will be a continuation of the second draft meeting. 8.0 Tom Delorie discussed the need for the development of fire protection requirements for spirals. The possibility of handling this by a TIA was discussed by the committee. Matt will send out an e mail to the technical committee in an effort to explore this option 9.0 The next meeting of the technical committee will be held for the first draft of the next revision cycle, in the spring of Page 2 of 2

9 1 of 50 2/21/2018, 1:28 PM Public Input No. 34-NFPA [ Global Input ] Add a chapter 12 to the document to cover wet chemical suppression. The chapter will contain chapters 4, 5, 6, and 7 of NFPA 17A as edited in the attached document titled DBrohmer_ All definitions of NFPA 17A used in chapters 4, 5, 6, and 7 will be added to chapter 3 of NFPA 120. All annexes to the sections in chapters 4, 5, 6, and 7 of NFPA 17A will be added to Annex A of NFPA 120. Additionally, Annex B of NFPA 17A will be added to NFPA 120. Additional Proposed Changes File Name DBrohmer_ docx LVS_Brochure_F pdf LVS_Data_Sheet_F pdf Description Approved Statement of Problem and Substantiation for Public Input Wet Chemical Fire Suppressions are now the {(State of The Art) for Vehicle Fire Suppression Systems}. This is not only for Ansul LVS Liquid Vehicle Systems which is what we use for vehicle fire suppression who we are a large manufacture of vehicle fire suppression systems for vehicle protection but competitive manufactures such as Amerex as well have gone to Wet Chemical Vehicle Fire Suppressions and Amerex is also present as a Committee Members on NFPA Standard 120 & 122. I am confident they will look forward to the change proposed. I am not saying to eliminate Dry Chemical Fire Suppression Systems. All hazard analysis conducted on every vehicle requiring protection now are wet chemical only. We no longer suggest, recommend or quote dry chemical fire suppression systems for vehicle fire protection. The only exception is with the Twin Agent Requirement for Large Hydraulic Excavators which is already called out in our 120 & 122 Standards and that will remain. Attached is a Data/Specification Sheet as well as a Wet Chemical Brochure for additional support in understanding the features & benefits of wet chemical systems in preventing re-flash & re-ignition of a vehicle involved in a fire. The usage of wet agent within vehicle suppression technology is quite significant. Through countless hours of testing and various outside 3rd party approvals, we have determined that the most reliable and most beneficial way to put out, and keep out fires, is to use a wet agent. This type of agent will not only effectively suppress fire, but in the vehicle world, will cool any superheated surfaces such as turbochargers and manifolds; typically the main ignition source for vehicle fires. We found that by cooling these components under auto-ignition temperatures of hydraulic and diesel fuels, the ability to re-flash after the end of a chemical discharge becomes minimal. Submitter Information Verification Submitter Full Name: Dennis Brohmer Organization: Tyco Fire Protection Products Street Address: City: State: Zip: Submittal Date: Fri Jan 12 13:24:07 EST 2018

10 NFPA- Wet Chemical Suppression System CONTENTS 12-. '" 5.2 System Actuation Supervision System Location Discharge Nozzles Special Requirements Chapter.3 Definitions General NFPA Official Definitions General Definitions Chapter 6 Plans and Acceptance Test. 6.1 Specifications Review and Certification Plans Approval of installations Chapter 7 Inspection, Maintenance, and Recharging 7.1 General Owner's Inspection Maintenance Recharging Hydrostatic Testing Service Collar..... Chapter 4 Components Annex A Explanatory Material..., General Detectors.,.... AnnexB Vehicle Fire Suppression Systems Discharge Nozzles Operating Devices Pipe and Fittings, Tubing, Hose Wet Chemical Electrical Wiring and Equipment Indicators....,..., Assembly..... Chapter 5 System Requirements General....,...,..... Annex D Index Informational References Edition

11 DEFINITIONS Chapter 3Definitions 3.1 General. The definitions contained in this chapter shall apply to the terms used in this standard. Where terms are not defined in this chapter or within another chapter, they shall be defined using their ordinarily accepted meanings within the context in which they are used. Webster's Collegiate Dictionary)', 11th edition, shall be the source for the ordinarily accepted meaning. 3.2 NFPA Official Definitions * Approved. Acceptable to the authority having jurisdiction.t * Authority Having Jurisdiction (AHJ). An organization, office, or individual responsible for enforcing the requirements of a code or standard, or for approving equipment, materials, an installation, or a procedure * Listed. Equipment, materials, or services included in a list published by an organization that is acceptable to the authority having jurisdiction and concerned with evaluation of products or services, that maintains periodic inspection of production of listed equipment or materials or periodic evaluation of services, and whose listing slates that either the equipment, material, or service meets appropriate designated standards or has been tested and found suitable for a specified purpose Shall. Indicates a mandatory requirement Should. Indicates a recommendation or that which is advised but not required Standard. An NFPA Standard, the main text of which contains only mandatory provisions using the word "shall" to indicate requirements and that is in a form generally suitable for mandatory reference by another standard or code or for adoption into law. Non-mandatory provisions are not Lo be considered a part of the requirements of a standard and shall be located in an appendix, annex, footnote, informational note, or other means as permitted in the NFPA Manuals of Style. When used in a generic sense, such as in the phrase "standards development process" or "standards development activities," the term "standards" includes all NFPA Standards, including Codes, Standards, Recommended Practices, and Guides. 3.3 Gene1 al Definitions Auxiliary Equipment. Listed equipment used in conjunction with the wet chemical systems, for example, to shut down fuel and power, to the hazard being protected or to initiate signaling devices Discharge Nozzle. Device from which the extinguishing agent is discharged to provide for suppression of a fire in the designated hazard Expellant Gas. The medium used to discharge extinguishing agent from its container Indicator. A mechanical or electrical device that shows when an extinguishing system or critical component of it is ready to operate or if it has already operated * Inspection. A visual examination of a system or portion thereof to verify that it appears to be in operating condition and is free of physical damage Liquid Agent. See , Wet Chemical Maintenance. Work, including, but not limited to, repair, replacement, and service, performed to ensure that equipment operates properly Manual * Manufacturer's Design, Installation, and Mai11te11a11ce Manual. The document referenced for design, installation, and maintenance of the listed wet chemical extinguishing system equipment Owner's Manual. A pamphlet containing the manufacturer's recommendations for inspection and operation of the extinguishing system Operating Devices. Mechanical electrical, or pneumatic devices involved in the operation of a system Operation Automatic Operation. Operation without human intervention Manual Operation. Operation of a system or its components through human action Pipe. Circular conduit for conveying the extinguishing agent Lo the discharge nozzle(s). Wherever pipe is used in this standard, it is understood to also mean tube * Pre-Engineered Systems. Those systems having predetermined flow rates, nozzle pressures, and quantities of extinguishing agent and having specific pipe size, maximum and minimum pipe lengths, flexible hose specifications, number of fittings, and number and types of nozzles Recharge. The replacement of the extinguishing agent and expellant gas Servicing. Performing maintenance, recharging, or hydrostatic testing Shutoff Devices. Devices that operate simultaneously with the extinguishing system to shutoff fuel and power to appliances protected by the system and other appliances required to be shut off upon operation of the system Edition

12 WET CHEMICAL EXTINGUISHING SYSTEMS Signal. An indication of a condition communicated by electrical, visible, audible, wireless, or other means Trained. A person who has undergone the instructions necessary Lo safely design, install, and reliably perform the maintenance and recharge service in accordance with the manufacturer's design, installation, and maintenance manual. [17,2017] Transport Canada (TC). The department that has jurisdiction over design and transportation of compressed gas cylinders and cartridges in Canada U.S. Department of Transportation (DOT). The department that has jurisdiction over the design and transportation of compressed gas cylinders and cartridges in the United States Wet Agent. See , Wet Chemical * Wet Chemical. Normally an aqueous solution of organic or inorganic salts or a combination thereof that foams Shutoff Devices. an extinguishing agent If the expellant gas is used to pneumatically operate Chapter 4 Components these devices, the gas connection shall be prior to entry into the wet chemical tank. 4.1 General. Only system components referenced or permit Shutoff devices shall require manual resetting prior t o fuel ted in the manufacturer's design, installation, and maintenance manual or alternative components that are listed for use with and or power being restored. the specific extinguishing system shall be used Used components shall not be permitted to be installed in new systems unless approved by the authority having jurisdiction. 4.2* Detectors. Detectors shall be listed devices that detect heat. 4.3 Discharge Nozzles. (See also Section 5.5.) Discharge nozzles shall be listed for their intended use Discharge nozzles shall be of brass, stainless steel, or other corrosion resistant mate1 ials or be protected inside and out against corrosion Discharge nozzles shall be made of noncombustible materials and shall withstand the expected fire exposure without deformation * Discharge nozzles shall be permanently marked for identification Protective Covers for Discharge Nozzles All discharge nozzles shall be provided with caps or other suitable devices to prevent the entrance of grease vapors, moisture, environmental contaminants, or other foreign mate- 1 ials into the piping The protection device shall blow off, blow open, or blow out upon agent discharge. 4.4 Operating Devices Operating devices shall be listed All operating devices shall be designed for the service they will encounter, shall not be rendered inoperative or susceptible to accidental operation, and shall operate at least from -40 F to 120 F (-40 C to 49 C) Manual Actuators Manual actuators shall not require a force of more than 40 lbs. to initiate operation All manual actuators shall be provided with operating instructions These instructions shall be pe1 milted lo include the use of pictographs and shall have lettering at least 1/4 in. (6.35 mm) in height All readily accessible manual operating devices shall identify the hazards they protect. 4.5 Pipe and Fittings, Tubing, Hose General. Pipe and associated fittings shall be of noncombustible material having physical and chemical characteristics compatible with the wet chemical solution Galvanized pipe and fittings shall not be used unless specifically listed with the system The pressure rating of the pipe fittings and connection joints shall withstand the maximum expected pressure in the piping system Edition

13 SYSTEM REQUIREMENTS * Pipe, tubing, hose, and types of fitting materials shall be in accordance with the manufacturer's design, installation, and maintenance manual. 4.6 Wet Chemical System Actuation * The wet chemical used in the system shall be listed All systems have both automatic and manual methods of actuation. for the particular system, and the system manufacturer shall be required to specify that particular chemical in the manufacturer's The automatic and manual means of system actuation, design, installation, and maintenance manual. external to the.releasing device, shall be separate and independent of each other so that a failure of one will not impair the operation Wet chemical solutions of different formulations or of the other so that failure of one will not impair the operation of different manufacturers shall not be mixed. the other. 4.7 Electrical Wiring and Equipment. Electrical wiring and equipment shall be installed in accordance with NFPA 70 or the requirements of the authority having jurisdiction. 4.8 Indicators. Wet chemical systems shall be provided with an audible or visual indicator to show that the system is in a ready condition or is in need of recharging. 4.9 Assembly * During assembly, the system shall be examined internally to detect and remove contaminants or other foreign materials All extinguishing agent storage containers shall be examined to ensure that they are fastened securely to their mounting brackets The manual means of system activation shall be permitted to be common with the automatic means if the manual activation device is located between the releasing device and the first fusible link Automatic detection and system actuation shall be in compliance with this standard and the manufacturer's design, installation, and maintenance manual All devices necessary for proper operation of the system shall function simultaneously witj1 the system operation Operation of any manual actuator shall be all that is required to bring about the full operation of the system At least one manual actuator shall be provided for each system All operating devices shall be designed, located, installed, or protected so that they are not subject to mechanical, Chapte1 5 System Requirements environmental, or other conditions that could render them In-operative or cause inadvertent operation of the system. 5.1 General. Wet chemical fire-extinguishing systems for the Protection of vehicles shall be listed and shall meet: Underwriters Laboratory Incorporated or Factory Global or AS-5062 (Australian Standard) An audible or visual indicator shall be provided. to show that the system has operated that personnel response is needed and that the system is need of recharge Use. Hazards and equipment that can be protected using wet chemical extinguishing systems shall include the follow * Applications. NFPA 120 & 122 and the manufacturer's design, Installation and maintenance shall be consulted for system limitations and applications for which wet chemical extinguishing systems for considered satisfactory protected* At least one manual actuation device shall be loca- ted in a means of egress m at a location acceptable to the authority having jurisdiction. in accordance with the authority having jurisdiction, within the limitations of the manufacturer's design, installation, and maintenance manual * The manual actuation device shall clearly identify the hazard protected and provide instructions for its use At least one manual actuation device shall be located The means for manual actuation shall be mechanical and shall not rely on electrical power for actuation Electrical power shall be permitted to be used for manual actuation if electrical supervision and a reserve power supply are provided in accordance with

14

15 WET CHEMICAL EXTINGUISHING SYSTEMS 5.3 Supervision Where electrical power is required to operate the fixed Automatic fire-extinguishing system, the system shall be monitored by a supervisory alarm with a reserve power supply provided Where supervision of any or all of the following is provided, i t shall be designed and installed to give an indication of trouble in the following: (1) Automatic detection system (2) Electrical actuation circuit (3) Electrical power supply Signals indicating the failure of supervised devices or equipment shall give prompt and positive indication of any failure and shall be distinct from signals indicating operation or hazardous conditions Where fixed automatic fire-extinguishing interconnected or interlocked with the vehicle power sources so that if the fireextinguishing system becomes inoperable due to power failure, all sources of fuel and power to the vehicle serviced l automatically shut off, and electrical power monitoring s h all not be required. 5.4 * System Location Wet chemical containers and expellant gas assemblies shall be located within the temperature range specified in the manufacturer's design, installation, and maintenance manual If ambient temperatures outside the manufacturer's operating temperature range are expected, protection shall be provided to maintain the temperature within the listed range Wet chemical containers and expellant gas assemblies shall not be located where they could be subjected to mechanical, chemical, or other damage Where damage due to chemical or mechanical exposure is expected, protective devices such as enclosures or guards acceptable to the authority having jurisdiction shall be provided Wet chemical containers and expellant gas assemblies shall be accessible for inspection, maintenance, and recharge. 5.4,6 Wet chemical containers and expellant gas assemblies shall be located per the manufacturer's limitations where they will not be exposed Lo the fire in the protected area or otherwise rendered inoperable by mechanical damage. 5.5* Discharge Nozzles. All discharge nozzles shall be loca- ted to minimize damage or misalignment and be within the limitations and constraints of the manufacturer's design, installation, and maintenance manual. (See Section 4.3.) 5.5 Special Requirements. 201 Edition

16 PLANS AND ACCEPTANCE TESTS.are properly protected with nozzles and positioned Chapter 6 Plans and Acceptance Tests 6.1 * Specifications. Specifications for wet chemical fireextinguishing systems shall be drawn up by or under the supervision of a trained person and with the advice of the authority having jurisdiction The following items shall be included in the specifications: (1) Designation of the authority having jurisdiction and indication of whether plans are required (2) Statement that the installation conforms to this standard and meets the approval of the authority having jurisdiction (3) Indication that only equipment referenced in the manufacturer's design, installation, and maintenance manual or alternative suppliers' components that are listed for use with the specific extinguishing system shall be used (4) Identification of special auxiliary equipment (5) List of the specific tests, if any, that are required (6) Identification of the hazard to be protected, including such information as physical dimensions, energy sources for. 6.2 * Review and Certification. Design and installation of systems shall be performed only by persons properly trained and qualified to design and/or install the specific system being provided. The installer shall provide certification to the authority having jurisdiction that the installation complies with the terms of the listing and the manufacturer's instructions and/or approved design. 6.3.l The plans shall be drawn to an indicated scale or shall be suitably dimensioned and shall be reproducible The plans shall contain sufficient detail to enable the authority having jurisdiction to evaluate the protection of the hazard(s) The details on the system shall include the following: (1) Size, length, and arrangement of connected piping (2) Description and location of nozzles Information shall be submitted pertaining to the following: (1) The location and function of detection devices (2) Operating devices (3) Auxiliary equipment (4) Electrical circuitry Approval of Plans. Where plans are required, they shall be submitted to the authority having jurisdiction for approval before work starts Where field conditions necessitate any substantial change from the approved plan, the as-installed plans shall be submitted to the authority having jurisdiction for approval. 6.4 Approval of Installations General. It shall be verified that the in accordance with the manufacturer's design, installation, and maintenance manual Mechanical Components It shall be ve1ified that pipe sizes and nozzles are in accordance with the manufacturer's design, installation, and maintenance manual Hose Integrity Test Prior to the test required by , hose shall be physically checked for tightness * A test using nitrogen or dry air shall be performed on the piping network at a pressure not to exceed the normal operating pressure of the extinguishing system The test shall verify that nitrogen or dry air has discharged out of each nozzle in the system The method of verification shall be acceptable to the authority having jurisdiction The hose shall be hydrostatically or replaced every 12-years Labeling. The labeling of devices with proper designations and instructions shall be verified. 6.3 Plans. Where plans are required, the responsibility for their preparation shall be entrusted only to trained persons Edition

17 WET CHEMICAL EXTINGUISHING SYSTEMS Review of Manual Release Devices. Verification that all manual devices (manual pull stations) are readily accessible and accurately identified shall be required System Operational Tests. System operational tests shall be performed in accordance with the manufacturer's design, installation, and maintenance manual and include functional tests of the automatic detection system, the manual release devices, the gas shutoff, the shutoff of makeup air supplied internally to a hood, and the electrical power shutdown Releasing Control Panel Where a releasing control panel is provided, verification that it is connected to a dedicated circuit and labeled properly shall be required Where a releasing control panel is provided, verification that it is readily accessible and restricted from unauthorized personnel shall be required Return of System to Operational Condition Verification that each extinguishing agent storage container is reconnected and the system has been returned to its fully operational condition shall be required After completion of functional testing, if the system is connected to an alarm-receiving office, the alarm-receiving office and all concerned personnel at the end user's facility shall be notified that the fire system test is complete and that the system has been returned to full-service operational condition * The installing contractor shall complete and sign an acceptance test report acceptable to the authority having jurisdiction The owner shall be provided with a copy of the manufacturer's design, installation, and maintenance manual or the owner's manual. (6) The pressure gauge(s), if provided, has been inspected physically or electronically to ensure it is in the operable range. (7) The nozzle blow-off caps, where provided, are intact and u undamaged. (8) The hazard has not changed, including replacement, modification, and relocation of protected equipment If any deficiencies are found, approp1iate corrective action shall be taken immediately Where the corrective action involves maintenance, it shall be conducted by a service technician as outlined in Personnel making inspections shall keep records for those extinguishing systems that were found to require corrective actions At least monthly, the date the inspection is performed and the initials of the person performing the inspection shall be recorded The records shall be retained for the period between the semiannual maintenance inspections. 7.3 Maintenance * A service technician who performs maintenance on an extinguishing system shall be trained and shall have passed a written or online test that is acceptable to the authority having jurisdiction I The service technician shall possess a certification document confirming the requirements in and issued by the manufacturer or testing organization that is acceptable to the authority having jurisdiction * A service technician who has the applicable manufactures design, installation, and maintenance manual and service bulletins shall service the wet chemical fireextinguishing system at intervals of no more than 6 months as outlined in * At least semiannually and aft.er any system Chapte1 7 Inspection, Maintenance, and Recharging activation, maintenance shall be conducted in accordance with the manufacture's design, installation, and maintenance manual. 7.1 General. The responsibility for inspection, testing, maintenance, and recharging of the fire protection system shall Maintenance shall include the following: ultimately be that of the owner(s) of the system, provided that responsibility has not been transferred in written form to a (1) A check to see that the hazard has not changed management company, tenant, or other party. 7.2 Owner's Inspection On a monthly basis, inspection shall be conducted in accordance with and the owner's manual The system owner shall maintain the design and installation documents and maintenance manual or owner's manual on the premises and shall make them available for review, upon request, by the authority having jurisdiction At a minimum, the inspection shall include verification of the following: (1) The extinguishing system is in its proper location. (2) The manual actuators are un-obstructed. (3) The tamper indicators and seals are intact. (4) The maintenance tag or certificate is in place. (5) No obvious physical damage or c onditionsexists that might prevent operation. (2) An examination of all detectors, the expellant gas container(s), the agent container(s), releasing devices, piping, hose assemblies, nozzles, signals, all auxiliary equipment, and the liquid level of all non-pressurized wet chemical containers (3) * Verification that the agent distribution is not obstructed * Where maintenance of any wet chemical containers reveals conditions such as, but not limited to, corrosion or pitting in excess of the manufacturer's limits; structural damage; fire damage; or repairs by soldering, welding, or brazing, the affected container shall be hydrostatically tested in accordance with Section 7.5 or replaced in accordance with the instructions of the manufacturer or the listing agency Where maintenance of any wet chemical system components reveals corrosion or pitting in excess of the manufacturer's limits, structural damage, or fire damage, the affected part(s) shall be replaced Edition

18 INSPECTION, MAINTENANCE, AND RECHARGING * All wet chemical systems shall be tested, which shall include operation of the detection system signals and releasing devices, including manual stations and other associated equipment Parts that are found during maintenance that could cause an impairment or failure of operation of the system shall be replaced by listed components as required by Section 4.lin accordance with the manufacturer's instructions l Until such repairs are accomplished, the systems shall be lagged as impaired, and the owner or owner's representative responsible for the system and, where required, the authority having jurisdiction shall be notified of the impairment When all repairs have been accomplished and the system has been restored to full operating conditions, all previously notified parties shall be informed that the system is in the full operating condition Heat detectors and all associated wiring that show signs of fire damage shall be replaced Expellant Gas. A method and instructions shall be provided for checking the amount or the pressure of expellant gas to ensure that it is sufficient for proper operation of the system Access. Sysṭem access. for inspection or maintenance not be permitted while any ted by that system is in operation. 7.4 Recharging. 7.4.l* Recharge. After any discharge or if insufficient charge is noted during an inspection or maintenance procedure, the following procedures shall be conducted in accordance with the manufacturer's design, installation, and maintenance manual: The maintenance report, including any (1) The system shall be recharged. recommendations, shall be filed with the owner or with the (2) The system shall be placed in the normal operating owner's representative. condition l The owner or owner's representative shall retain all maintenance reports for a period of 1year after the next maintenance of that type required by the standard * Each wet chemical system shall have a tag or label (3) Following a discharge, the piping shall be flushed and blown out with dry air or nitrogen in accordance with the manufacturer's design, installation, and maintenance manual. Securely attached, indicating the month and year the maintenance is performed and identifying the person performing the service. Only the current tag or label shall remain in place l *Replacement fixed temperature-sensing elements shall be listed and shall be the same temperature ratings as the ones being replaced unless temperature readings dictate a need for a change Fixed temperature-sensing elements shall be permitted to remain continuously in service, provided they are inspected and cleaned or replaced, if necessary, in accordance with the manufacturer's instructions, every 12 months or more frequently to ensure proper operation of the system AL a minimum, maintenance of restorable-type heat detectors shall include the following: (1) A visual inspection to determine whether there is damage to the detector or buildup of foreign debris (2) An operational/functional test in accordance with the detector manufacturer's testing instn1ctions (3) A calibration verification test, if applicable, in accordance with the detector manufacturer's instructions Nonrestorable heat detectors shall be functionally tested in accordance with the manufacturer's instructions Systems shall be recharged in accordance with the manufacturer's design, installation, and maintenance manual After any discharge, the system piping shall be flushed and blown out with dry air or nitrogen in accordance with the procedures detailed in the manufacturer's design, installation, and maintenance manual * Storage. Recharging supplies of wet chemical shall be stored in the original closed shipping container supplied by the manufacturer These containers shall not be opened until the system is recharged Wet chemical supplies shall be maintained within the manufacturer's specified storage temperature range. 7.5* Hydrostatic Testing The following parts of wet chemical extinguishing systems shall be subjected to a hydrostatic pressure test at intervals not exceeding 12 years: (1) Wet chemical containers (2) Auxiliary pressure containers ( 3) Hose assemblies.exception No. 1: Auxiliary pressure containers not exceeding 2 in. (0.05 m) outside diameter and less than 2ft (0.6 m) in length. Exception No. 2: Auxiliary pressure containe1:s bearing the DOT "3E" marking Wet chemical containers, auxiliary pressure containers, and hose assemblies shall be subjected to a hydrostatic test pressure equal to the marked factory test pressure or the test pressure specified in the manufacturer's design, installation, and maintenance manual No leakage, rupture, or movement of hose couplings shall be permitted. 201%Edlt!on

19 WET CHEMICAL EXTINGUISHING SYSTEMS The pressure in a hydrostatic test of a cylinder shall be maintained for a minimum of 30 seconds, but for no less time than is required for complete expansion of the cylinder and to complete the visual examination of the cylinde1: Prior to being refilled or transported, in accordance with DOT or TC requirements, containers bearing DOT or TC markings shall be retested or replaced in accordance with the appropriate DOT or TC requirements Wet chemical agent removed from the containers prior to hydrostatic testing shall be discarded To protect the hazard during hydrostatic testing, if there is no connected reserve, alternative protection acceptable to the authority having jurisdiction shall be provided. 7.6 Service Collar Each system container that has undergone maintenance that includes internal examination or has been recharged shall have a verification-of service collar located around the neck of the container. [17: ] The collar shall not inte1 fere with the operation of the system container discharge valve. [17: ] The collar shall include the following information: (1) Month and year the service was performed, indicated by a perforation such as done by a hand punch (2) Name of the agency performing the maintenance or recharge [17: ] Cartridge- or cylinder operated wet chemical system containers shall not be required to comply with 7.6.l through [17: ] The collar shall be a single circular piece of uninterrupted material forming a hole of a size that does not permit the collar assembly to move ove1 the neck of the container unless the valve is completely removed. Annex A Explanatory Material Annex 1l is not a part of the requirements of this NFPA document bul is included for informational purposes only. This annex contains explanation, numbered to correspond with the applicable text paragraphs. A.1.1 The wet chemical systems described in this standard are designed to discharge wet chemical from fixed nozzles and Hose by means of expellant gas. The intent of the standard is to present the design considerations applicable to these systems. The wet chemicals produced by va1ious manufacturers usually are not identical in all characteristics, and each manufacturer designs equipment for use with a specific wet chemical. Therefore, system design principles applicable to the products of one manufacturer are not applicable to the products of another manufacture1: As a result, it is not practical to include system design details as part of this standard. However, such system design details are an integral part of the listing of the systems and are included in the manufacturers' design, installation, and maintenance manuals. A.1.3 See Annex B for recommendations for installation of vehicle fire suppression system applications. 201f Edition A See IEEE/ASTM SI 10, American National Standard for Metric Practice. A.1.7 Although training and qualification might be available elsewhere, it is recommended that such training and qualification be performed by the manufacturer of the equipment being installed or serviced or by the manufacturer's agent. It might be necessary for many of those charged with the purchasing, inspecting, testing, approving, operating, and maintaining of this equipment to consult an experienced fire protection engineer competent in this field, in order to discharge their duties effectively. A Approved. The National Fire Protection Association does not approve, inspect, or certify any installations, procedures, equipment, or materials; nor does it approve or evaluate testing laboratories. In determining the acceptability of installations, procedures, equipment, or materials, the authority having jurisdiction may base acceptance on compliance with NFPA or other appropriate standards. In the absence of such standards, said authority may require evidence of proper installation, procedure, or use. The authority having jurisdiction may also refer Lo the listings or labeling practices of an organization that is concerned with product evaluations and is thus in a position to determine compliance with appropriate standards for the current production of listed items. A Authority Having Jurisdiction (AHJ). The phrase "authority having jurisdiction," or its acronym AHJ, is used in NFPA documents in a broad manner, since jurisdictions and approval agencies vary, as do their responsibilities. Where public safety is primary, the authority having jurisdiction may be a federal, state, local, or other regional department or indi-vidual such as a fire chief; fire marshal; chief of a fire prevention bureau, labor department, or health department; building official; electrical inspector; or ot11ers having statutory authority. For insurance purposes, an insurance inspection department, rating bureau, or other insurance company representative may be the authority having jurisdiction. In many circumstances, the prope1 ty owner or his or her designated agent assumes the role of the authority having jurisdiction; at government installations, the commanding officer or depart- mental official may be the authority having jurisdiction. A Listed. The means for identifying listed equipment may vary for each organization concerned with product evaluation; some organizations do not recognize equipment as listed unless it is also labeled. The authority having jurisdiction should utilize the system employed by the listing organization to identify a listed product. A Inspection. This is done by verifying that the system is in place, that it has not been activated or tampered with, and that there is no obvious physical damage or condition to prevent operation. A Manufacturer's Design, Installation, and Maintenance Manual. It contains a description of the hazards that can be protected as well as the limitations of the wet chemical extinguishing system. This manual also requires that the wet chemical extinguishing system be designed, installed, inspected, maintained, and serviced in accordance with NFPA l7a. A Operating Devices. Operating devices include "actuating devices," which initiate operation (automatic detection devices or systems), and manual pulls or strike buttons

20 ANNEX A That respond to the actuation (release mechanisms, shutoff devices, alarms, and auxiliary equipment). A Pre-Engineered Systems. Pre-Engineered systems should be listed by a testing laboratory. The maximum and minimum pipe lengths and the number of fittings should be permitted to be expressed in equivalent feet (meters) of pipe. The hazards protected by these systems should be limited as to type and size based on actual fire tests. Limitations on hazards that are permitted to be protected by these systems are contained in the manufacturer's design, installation, and maintenance manual, which is part of the listing of the system. A Wet Chemical. The terms liquid agent and wet agent are used interchangeably with wet chemical, A.4.2 Fixed temperature-sensing element brackets should be installed so that the brackets do not shield the detector from the heat of the cooking appliances. A Stamping part numbers into the body of the nozzle is an acceptable method of meeting the identification requirement. A Pre-engineered systems do not need calculations for flow rate, pressure drop, and nozzle pressure, since they have been tested for fire extinguishment with minimum and maximum piping limitations and minimum and maximum temperature limitations. These limitations have been verified by testing laboratories and are published in the manufacturer's design, installation, and maintenance manual. Therefore, it is not necessary for a professional engineer or architect to seal the design of 1ese systems. or A Pipe and fittings should be installed in accordance with good commercial practices. Care should be taken to avoid possible restrictions due to foreign matter, faulty fabrication, or improper installation. The following is considered a good practice: The solution's effect on fires in form a vapor suppression foam that floats on a liquid surface, effectively preventing re-ignition of the fire. Extinguishing Mechanisms. Wet chemical solution applied to flammable liquid surfaces results in the rapid spreading of a vaporsuppressing foam on the fuel surface. The foam extinguishes and secures the flame by forming a barrier between the liquid fuel and oxygen. This barrier excludes oxygen from the fuel source and eliminates the release of flammable vapors from the fuel surface. The cooling effect of this solution also lowers the temperature of the flammable fuel, further decreasing fuel vapor release. CAUTION: Wet chemical, when discharged, is in the form of a fine spray. Some of the agent can settle on surrounding surfaces and can have a corrosive effect on electrical components and cooking equipment. Prompt cleanup will minimize staining or corrosion. A.4.9.l Contaminants and foreign materials can affect the extinguishing agent distribution due to a reduction in the effective nozzle orifice area. t,>e. /l)..s / ( q - rf l'f t )rr/(j rc-.jj t o. 1 /j_o'(-/.u-. U A NFP, S JN, specifies thal the auto- - (1) Prior to assembly, hose should be cleaned internally by means of suitable nonflammable cleaner. (2) Once hose is assembled and prior to nozzle installation, the entire hose system should be blown out with nitrogen or dry air. (3) The hose is should be securely supported and should not be subject to mechanical, chemical, or other damage. (4) All piping should be installed in pipe hanger or brackets and fastened to rigid surfaces. (5) All hose mounting brackets, hangers, and support fixtures should be installed in a manner that ensures nozzles are properly aligned and that prevents nozzles from being (6) moved out of alignment. A union should be installed between the extinguishing agent storage container and the supply line. A A wet chemical solution generally includes, but is not limited to, a potassium carbonate-based, potassium acetatebased, potassium citrate-based solution or a combination thereof and is mixed with water to form an alkaline solution capable of being discharged through piping or tubing when under expellant gas pressure. 201 Edition

21 11Wz --- WET CHEMICAL EXTINGUISHING SYSTEMS A.6.1 One of the first steps in the design and installation of a Fire extinguishing system should be to maintain complete and accurate records. Establishment of a job file will provide a means of documentation. A job file should contain all drawings, sketches, checklists, notes, maintenance agreements and 2019 Edition correspondence related to the installation om start to finish. Photographs are encouraged and should include a wide shot that shows the location of all in the protected area at the time of installation. The photographs, as well as any checklists, drawings, or sketches, should be signed and dated. A.6.2 Manufacturers of fire suppression system equipment should make available the manufach1re1 's design, installation, and maintenance manual and product safety bulletins to the authority having jurisdiction upon request. A The test is intended to verify that flow is continuous and that the piping and nozzles are reasonably unobstructed. The nitrogen or dry air should be introduced into the piping network at the extinguishing agent container connection using a test cylinder or other suitable source. The quantity of nitrogen or dry air used for this test should be sufficient to verify that each nozzle is unobstructed. Nozzle flow should be verified at each discharge nozzle. A Figure A is an example of an acceptance test report. A A reasonable program for qualification of service technicians is for an individual to pass a written or online examination. The Lest should contain a reasonable number of questions Lo challenge the individual's knowledge of the subject matter. A It is recommended that system maintenance personnel be certified as outlined in It is standard industry practice to provide expiration dates on certificates. A Regular service contracts are recommended.

22 WET CHEMICAL SYSTEM ACCEPTANCE TEST REPORT System manufacturer/model: System Check or Test Results _ Installation in accordance with approved plans, where required, and manufacturer's design, installation, and.maintenance manual Piping test ( ) Proper labeling (6.4.5) Proper alarm operation (6.4.6) Manual release accessibility (6.4.7) Releasing control panel (6.4.9) Automatic detection & manual release (6.4.8) System properly charged and left in normal "set" condition (6.4.10) Manual left with owne1 ( ) Date system left in se1 vice: Test Witnessed By: Owner/Authorized agent Title Date Installing contractor Title Date Additional comments: 2016 National Fire Protection Association NFPA 17A FIGURE A Sample Wet Chemical System Acceptance Test Report. 2019Edltlon

23 ' Vl'ET CHEMICAL EXTINGUISHING SYSTEMS A (3) The following methods can be used la verify that piping is not obstructed: (1) Disassembly of all-hose & pipe (2) Conducting a full or partial discharge test (3) Utilizing other methods recommended by the manufacturer A The hydrostatic testing of wet chemical containers should follow the applicable procedures outlined in Section 7.5. A A discharge of the wet chemical normally is not part of this test. A Under special circumstances or when local requirements are in effect, additional infom1ation can be desirable or required. A Fixed temperature-sensing element are manufactured to operate at predetermined temperatures, causing the system to discharge. Fixed temperature sensing elements are typically listed with the temperature ratings shown in Table A It is important to select fixed temperature-sensing elements that respond in a timely manner during a fire but that do not result in an unwanted discharge. It is also important to periodically take a temperature reading at each installation location Lo ensure the replacement devices arc appropriate for each location. Improper selection of replacement devices could result in an unwanted discharge or a delayed response. A.7.4.l Wet chemical solutions normally have no lasting significant effects on the skin, respiratory system, or clothing. They can produce mild temporary skin irritation after prolonged skin exposure, but symptoms usually disappear when contact is eliminated. Irritation of the eyes should be treated by flushing with tap water for 15 minutes or longer. Any condition of prolonged irritation should be referred to a physician for treatment. Table A Typical Temperature Ratings of Fixed Temperature-Sensing Elements Temperature Maximum Ambient Temperature Temperature Rating Class F c F c Low Ordinary Intermediate High Extra high Very extra high Ultra high Treatment of skin irritation due to exposure to wet chemical is best handled by flushing with water. These systems investigated to determine that they do not splash burning when installed in accordance with the manufacturer's design, installation, and maintenance manual. It is known that e is moderately irritating to the skin and eyes and t at repeated skin contact can lead to dermatitis, but t11is is based on concentrations higher than those used in wet chemical extinguishing system units. A The characteristics of the system are dependent on the composition of the wet chemical solution and the type of expellant gas, as well as other factors; therefore, i t is imperative to use the wet chemical provided by the manufacturer of the system and the type of expellant gas specified by the manufacturer of the system. Systems are designed on the basis of the flow and extinguishing characteristics of a specific formulation of wet chemical. Storage of wet chemical solution in containers other than those supplied by the manufacturer can result in agent contamination 01 deterioration and confusion regarding its identity. A.7.5 DOT- or TC-marked cylinders can be required to be subjected to more frequent testing. A DOT- or TC-marked containers installed in a system not under the jurisdiction of DOT or TC arc not required to follow DOT or TC requirements as long as they remain in operation. Annex B Vehicle Fire Suppression Systems This annex is not a part of the requirements of this NF PA document but is ij1clttded for informational purposes only. B.1 Only pre-engineered wet chemical systems, including detection systems that have been listed for such use, should be used for vehicle fire suppression systems and should not include cooking appliances inside the vehicle. B.2 Compartments or areas that could be subject to fire should be protected in accordance with the manufacturer's design, installation, and maintenance manual. B.3 Each protected compartment or area should be provided with a listed fire detection device specified in the manufacturer's design, installation, and maintenance manual to automatically actuate the extinguishing system. B.4 Manna! Actuation should be permitted to be provided only if acceptable Lo the authority having jurisdiction. B.5 Only the flexible hose and hose fittings specified in the manufacturer's design, installation, and maintenance manual should be used. B.6 All discharge nozzles should be located to minimize the likelihood of damage or mis-alignment and within the limita-tions and constraints of the manufacturer's design, installation, and maintenance manual. B.7 Location of agent containers, expellant gas cartridges or cylinders, and a manual actuator station(s) should be appropriate to each application, protected against physical damage, and accessible Editlon

24 ANNEX D B.8 At least one easily accessible manual actuator or operating device should be provided for use by the equipment operator. B.9 An additional manual actuator or operating device should be located, if practical, so that it is in the path of egress and operable from the ground level. B.10 If the system is provided with a discharge delay device, both audible and visual alarms should be provided Lo warn of impending system discharge. B.11 In the event of system discharge, the vehicle being protected should not be returned to service until the system is recharged and operational. Annex D Informational References D.1 Referenced Publications. The documents or portions thereof listed in this annex are referenced within the informational sections of this standard and are not part of the requirements of this document unless also listed in Chapter 2 for other reasons. D.1.1 NFPA Publications. National Fire Protection Association, 1Batterymarch Park, Quincy, MA NFPA 10, Standard for Par/able Fire Extinguishers, 2017 edition. NFPA 72, National Fire Alarm and Signaling Code, 2016 edition. NFPA 17A Standard for Wet Chemical Fire Suppression Systems 2017 edition. D.1.2 Other Publications. D ASTM Publications. ASTM International, 100 Barr Harbor Drive, P,O, Box C700, West Conshohocken, PA IEEE/ASTM SI 10, American National Standard for Metric Practice, D.2 Informational References. The following documents or portions thereof are!isled here as informational resources only. They are not a part of the requirements of this document. D.2.1 U.S. Government Publications. U.S, Government Publishing Office, 732 North Capitol Street, NW, Washington, DC Title 49, Code of Federal Regulations, Parts 'Edition

25 WET CHEMICAL EXTINGUISHING SYSTEMS Index Copyright 2016 National Fire Protection Association. All Rights Reserved. The copyright in this index is separate and distinct from the copyright in the document that it indexes. The licensing provisions set forth for the document are not applicable to this index. This index may not be reproduced in whole or in part by any means without the express written permission of NFPA. Administration, Chap. 1 Application, 1.3, A. 1.3 Indicator Definition, I- Equivalency, 1.5 Purpose, 1.2 Qualifications, 1.7, A.1.7 Retroactivity, 1.4 Scope, I.I, A.1.1 Units and Formulas, 1.6 Approved Definition, 3.2.l, A Authority Having Jurisdiction (AHJ) Definition, 3.2.2, A Auxiliary Equipment Definition, 3.3.l Components, Chap. 4 Assembly, 4.9 Detectors, 4.2, A.4.2 Discharge Nozzles, 4.3 Protective Covers for Discharge Nozzles, Electrical Wiring and Equipment, 4.7 General, 4.1 Indicators, 4.8 Operating Devices, 4.4 Manual Actuators, Shutoff Devices, Pipe and Fittings, Tubing, Hose, 4.5 General, 4.5.l, A Wet Chemical, 4.6 Definitions, Chap. 3 Discharge Nozzle Definition, Duct Branch Duct Definition, l Common Duct Definition, Definition, Expellant Gas Definition, Explanatory Material, Annex A -E- Informational References, Annex D Inspection Definition, 3.3.6, A Inspection, Maintenance, and Recharging, Chap. 7 General, 7.1 Hydrostatic Testing, 7.5, A.7.5 Maintenance, 7.3 Access, Expellant Gas, Owner's Inspection, 7.2 Recharging, 7.4 Recharge, 7.4.1, A Storage, 7.4.4, A Service Collar, 7.6 Liquid Agent Definition, Listed Definition, 3.2.3, A Maintenance Definition, Manual Definition, Manufacturer's Design, Installation, and Maintenance Manual Definition, , A Owner's Manual Definition, Operating Devices Definition, , A Operation Automatic Operation Definition, 3,3.11.l Definition, Manual Operation Definition, P- Pipe Definition, Plans and Acceptance Tests, Chap. 6 Approval of lnstallations, 6.4 Appliances, 6.4.3

26 INDEX Building Alarm System, General, Labeling, Mechanical Components, Piping Integrity Test, Releasing Control Panel, Return of System to Operational Condition, Review of Manual Release Devices, System Operational Tests, Plans, 6.3 Approval of Plans, Review and Certification, 6.2, A.6.2 Specifications, 6.1, A.6.1 Pre-Engineered Systems Definition, , A R- Recharge Definition, Referenced Publications, Chap. 2 -S- System Requirements, Chap. 5 Discharge Nozzles, 5.5, A.5.5 General, 5.1 Applications, 5.l.2, A Use, Special Requirements, 5.6 Protection of Common Exhaust Duct, Supervision, 5.3 System Actuation, 5.2 System Location, 5.4, A.5.4 Systems for Protection of Residential Stoves When Used in Otl1er than Commercial Cooking Operations, Annex C Trained Definition, Transport Canada (TC) Definition, T- -U- U.S, Department of Transportation (DOT) Definition, Servicing Definition, Shall Definition, Should Definition, Shutoff Devices Definition, Signal Definition, Standard Definition, V- Vehicle Fire Suppression Systems, Annex B Wet Agent Definition, Wet Chemical Definition, , A W KP {Edition

27 Sequence of Events for the Standards Development Process Committee Membership Classifications Once the current edition is published, a Standard is opened for Public Input. Step 1- Input Stage Input accepted from the public or other committees for consideration to develop the First Draft Technical Committee holds First Draft Meeting to revise Standard (23 weeks); Technical Committee{s) with Correlating Committee (10 weeks) Technical Committee ballots on First Draft ( 12 weeks); Technical Committee (s) with Correlating Committee (11 weeks) Correlating Committee First Draft Meeting {9 weeks) Correlating Committee ballots on First Draft (5 weeks) First Draft Report posted on the document information page Step 2 - Comment Stage Public Comments accepted on First Draft (10 weeks) following posting of First Draft Report If Standard does not receive Public Comments and the Technical Committee chooses not to hold a Second Draft meeting, the Standard becomes a Consent Standard and is sent directly to the Standards Council for issuance (see Step 4) or Technical Committee holds Second Draft Meeting (21 weeks); Technical Committee(s) wit11 Correlating Committee (7 weeks) Technical Committee ballots on Second Draft (11 weeks); Technical Committee(s) with Correlating Committee (10 weeks) Correlating Committee Second Draft Meeting (9 weeks) Correlating Committee ballots on Second Draft (8 weeks) Second Draft Report posted on the document information page Step 3 -NFPA Technical Meeting Notice of Intent to Make a Motion (NITMAM) accepted (5 weeks) following the posting of Second Draft Report NITMAMs are reviewed and valid motions are certified by the Motions Committee for presentation at the NFPA Technical Meeting NFPA membership meets each June at the NFPA Technical Meeting to act on Standards with "Certified Amending Motions" (certified NITMAMs) Committee(s) vote on any successful amendments to the Technical Committee Reports made by the NFPA membership at the NFPA Technical Meeting Step 4 - Council Appeals and Issuance of Standard Notification of in ten t to file an appeal to the Standards Council on Technical Meeting action must be filed witj1in 20 days of the NFPA Technical Meeting Standards Council decides, based on all evidence, whether to issue the standard or to take other action Notes: L Time periods are approximate; refer to published schedules for actual dates. 2. Annual revision cycle documents with certified amending motions take approximately 101weeks to complete. 3. Fall revision cycle documents receiving certified amending motions take approximately 141weeks to complete. &; The following classifications apply to Committee members and represent their principal interest in the activity of the Committee. 1. M Manufacturer: A representative of a maker or marketer of a product, assembly, or system, or portion thereof, that is affected by the standard. 2. U User: A representative of an entity that is subject to the provisions of the standard or that voluntarily uses the standard. 3. IM Installer/Maintainer: A representative of an entity that is in the business of installing or maintaining a product, assembly, or system affected by the standard. 4. L Labor: A labor representative or employee concerned with safety in the workplace. 5, RT Applied Research/Testing Laboratory: A representative of an independent testing laboratory or indepen dent applied research organization that promulgates and/or enforces standards. 6. E Enforcing Authority: A representative of an agency or an organization that promulgates and/or enforces standards. 7. I Insurance: A representative of an insurance company, broker, agent, bureau, or inspection agency. 8. C Customer: A person who is or represents the ultimate purchaser of a product, system, or service affected by the standard, but who is not included in (2), 9. SE Special Expert: A person not representing (1) through and who has special expertise in the scope of the standard or portion thereof. NOTE 1: "Standard" connotes code, standard, recommended practice, or guide. NOTE 2: A representative includes an employee. NOTE 3; While these classifications will be used by the Standards Council to achieve a balance for Technical Committees, the Standards Council may determine that new classifications of membe1 or unique interests need representation in order to foster the best possible Committee deliberations on any project. In this connection, the Standards Council may make such appointments as it deems appropriate in tl1e public interest, such as the classification of "Utilities" in the National Electrical Code Committee. NOTE 4; Representatives of subsidiaries of any group are generally considered to have the same classification as the parent organization.

28 . Submitting Public Input / Public Comment Through the Online Submission System Soon after the current edition is published, a Standard is open for Public Input. Before accessing the Online Submission System, you must first sign in at Note: You will be asked to sign-in or create a free online account with NFPA before using this system: a. Click on Sign In at the upper right side of the page. b. Under the Codes and Standards heading, click on the "List of NFPA Codes & Standards," and then select your document from the list or use one of the search features. OR a. Go directly to your specific document information page by typing the convenient shortcut link of (Example: NFPA 921 would be Sign in at the upper righ t side of the page. To begin your Public Input, select the link ''The next edition of this standard is now open for Public Input" located on the About tab, Current & Prior Editions tab, and the Next Edition tab. Alternatively, the Next Edition tab includes a link to Submit Public Input online. At this point, the NFPA Standards Development Site will open showing details for the document you have selected. This "Document Home" page site includes an explanatory introduction, information on the current document phase and closing date, a left-hand navigation panel that includes useful links, a document Table of Contents, and icons at the top you can click for Help when using the site. The Help icons and navigation panel will be visible except when you are actually in the process of creating a Public Input. Once the First Draft Report becomes available there is a Public Comment period during which anyone may submit a Public Comment on the First Draft. Any objections or further related changes to the content of the First Draft must be submitted at the Comment stage. To submit a Public Comment you may access the online submission system utilizing the same steps as previously explained for the submission of Public Input. For further information on submitting public input and public comments, go to: public input. Other Resources Available on the Document Information Pages About tab: View general document and subject-related information. Current & Prior Editions tab: Research current and previous edition information on a Standard. Next Edition tab: Follow the committee's progress in the processing of a Standard in its next revision cycle. Technical Committee tab: View current committee member rosters or apply to a committee. Technical Questions tab: For members and Public Sector Officials/AHJs to submit questions about codes and standards to NFPA staff. Our Technical Questions Service provides a convenient way to receive timely and consis-tent technical assistance when you need to know more about NFPA codes and standards relevant to your work. Responses are provided by NFPA staff on an informal basis. Products & Training tab: List of NFPA's publications and training available for purchase.

29

30 PRODUCT OVERVIEW PRODUCT OVERVIEW LVS Fire Suppression System Protect mobile equipment with liquid agent n Rapid flame knockdown, cooling and securement n Automatic or manual operation n 24/7 fire detection n Multiple design options n FM approved and CE marked Industries rely on their heavy mobile equipment to work around the clock, and the fire protection needs to work 24/7 too. The ANSUL LVS Liquid Agent Fire Suppression System is designed to suppress fires in mobile equipment used in a wide range of industries including mining, forestry, waste management, transportation and others. Suppress Mobile Equipment Fires The LVS fire suppression system agent provides both fire suppression and superior cooling of superheated surfaces while blanketing the fuel and cutting off oxygen to help prevent reflash. It flows readily into hard-to-reach areas along the same path flammable liquids may have flowed. The wet chemical agent provides a strong measure of freeze protection along with the foaming properties associated with conventional Class B liquid agents. Additional system features include the option of a stand-alone, liquid agent system or a twin-agent concept with dry chemical; 20- to 60-second discharge effective on Class A combustibles; pre-mixed 3 gal (11.4 L) or 5 gal (18.9 L) containers for convenient filling of the agent tank; tank capacity of 3 gal to 30 gal (11.4 L to L); ease of maintenance and recharge; proven external pressurization cartridge; effective operating range of -40 F to 140 F (-40 C to 60 C); flexible design and installation parameters; and multiple detection and actuation options. Protection Starts with 24/7 Detection The CHECKFIRE system is used with the LVS system to provide around-the-clock, automatic, fire detection and actuation. The rugged control module is designed to withstand shock, vibration and extreme environmental conditions. The CHECKFIRE system includes supervised circuitry, adjustable shutdown, discharge time delays and auxiliary shutdown relay.

31 THE LVS FIRE SUPPRESSION SYSTEM CAN BE FOUND ON VEHICLES AND EQUIPMENT IN THESE INDUSTRIES Agribusiness Aviation Forestry Metal processing Mining Power generation/utilities Transportation Waste processing The Ultimate Fire Suppression Solution The ANSUL brand promises a full range of quality fire protection solutions from automatic detection and suppression systems to a complete line of wheeled and hand portable fire extinguishers and more. Plus, our extensive network of Authorized ANSUL Distributors provides factory-trained professionals to serve our customers virtually anywhere in the world. A Passion for Protection Dedicated customer support. Extensive product portfolio. Engineering excellence. Trusted, proven brands. Tyco Fire Protection Products offers all of these attributes, plus a passion for protection. It s what drives us to create solutions to help safeguard what matters most your valued people, property and business. One Stanton Street l Marinette, WI , USA l l Copyright 2015 Tyco Fire Products LP. l All rights reserved. l Form No. F

32 DATA SHEET LVS Liquid Agent Fire Suppression System Features n Versatility Stand-alone liquid agent system or in a Twin- Agent concept with dry chemical n Wet Chemical Agent A blend of organic and inorganic salts coupled with surface active ingredients n Pre-mixed 3 gal (11.4 L) and 5 gal (18.9 L) containers Allows for convenient filling of the agent tank n Effective on Class A and Class B fires n Wide temperature operating range of 40 F to 140 F ( 40 C to 60 C), CE temperature rating is 22 F to 140 F ( 30 C to 60 C) n Does not require annual agent replacement n LVS Agent shelf life may exceed 20 years when stored in original plastic container n Field-proven cooling agent LVS Agent has been used in ANSUL Twin-Agent Systems around the globe since 1998 n Rugged construction n Ease of maintenance and recharge n Mild steel agent tanks in multiple sizes n Rigid seismic ring mounting brackets for LVS-15 and LVS-30 tanks n LVS-3, LVS-5, and LVS-10 tanks can be mounted horizontally or vertically n Proven external pressurization cartridge Provides constant nozzle pressure and full discharge pattern throughout duration of discharge n 1/2 in. Brass Discharge Nozzles with 45 discharge pattern n Utilizes standard SAE 100 R1 or 100 R5 hose; or stainless steel tube meeting ATM A213 or ASME SA 213, 316L tubing specifications n Flexible design and installation parameters n Multiple detection and actuation options n CE Marked n FM Approved n AS 5062 Compliant Application LVS Liquid Agent Fire Suppression System: The ANSUL LVS Liquid Agent stand-alone fire suppression system can protect the following types of equipment: On-Road Vehicles Non-Road Vehicles/Equipment Public transportation Landfill equipment Waste management Forestry vehicles Over-the-road trucking Construction equipment Cargo transport Mining equipment Intermodal above ground and sub-surface: Haul trucks Specialty Vehicles Wheeled loaders Slag carriers Dozers Pot carriers Scooptrams Iron/steel slab carriers Shuttle cars Tunnel boring machines The system suppresses fires and helps to secure hazard areas by various means: n The LVS wet chemical agent formulation, sprayed into fire hazard areas, interrupts the chemical reaction that supports combustion n The liquid agent can flow into areas where flammable liquids also flow n The LVS agent formulation forms a film over flammable fuels, which also minimizes reflash potential n The LVS wet chemical solution cools the fuel and the surrounding super-heated surfaces, reducing the possibility for fire re-ignition One Stanton Street / Marinette, WI , USA / / Copyright 2015 Tyco Fire Products LP. / All rights reserved. / Form No. F

Technical Committee on Mining Facilities First Draft Meeting - NFPA 120 and 122

Technical Committee on Mining Facilities First Draft Meeting - NFPA 120 and 122 Technical Committee on Mining Facilities First Draft Meeting - NFPA 120 and 122 Zurich Hosted 1400 America Lane Schaumburg, Illinois May 22 23, 2013 AGENDA 1. Chair Matt Bujewski calls meeting to order

More information

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM of 25 7/30/2015 1:35 PM First Revision No. 49-NFPA 17A-2015 [ Detail ] Make the following change to 5.2.1.10.2: 5.2.1.10.2* The manual actuation device shall clearly identify the hazard protected and provide

More information

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM 1 of 14 6/22/2016 3:15 PM Second Revision No. 1-NFPA 17A-2016 [ Section No. 4.3.3 ] 4.3.3 All discharge nozzles shall be provided with caps or other suitable devices to prevent the entrance of grease vapors,

More information

NFPA 96, 2017 REVIEW SUMMARY

NFPA 96, 2017 REVIEW SUMMARY NFPA 96, 2017 REVIEW SUMMARY 1) NFPA 96 REVISION SUMMARY NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations The 2017 edition adds a new normative annex on mobile

More information

Types of Detection. Fusible Link Detection - Most Common

Types of Detection. Fusible Link Detection - Most Common Types of Detection Fusible Link Detection - Most Common Types of Detection Electric Detection Types of Detection Pneumatic Detection-Tubing Pneumatic Tubing 3 Year Service life Survey Hazard 1) List all

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-21 21 03.00 10 February 2009) ---------------------------------- Preparing Activity: USACE Superseding UFGS-21 21 03.00 10 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS (By authority conferred on the director of the department of licensing and regulatory affairs by sections

More information

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM 1 of 11 1/18/2016 5:43 PM First Revision No. 2-NFPA 51-2015 [ Global Input ] Throughout standard remove references to the following and replace with the following: (1) CGA C-7 Guide to Precautionary Labelling

More information

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION WET-PIPE SPRINKLER SYSTEMS SECTION 21 13 13 WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SCOPE OF WORK A. Design, installation and testing shall be in accordance with NFPA 13 except for specified exceptions. B. The demolition

More information

OWNER'S OPERATION AND MAINTENANCE MANUAL

OWNER'S OPERATION AND MAINTENANCE MANUAL OWNER'S OPERATION AND MAINTENANCE MANUAL P/N 15064 Amerex Industrial Dry Chemical Fire Suppression System MODELS IS18ABC (18 lb. ABC) / IS35ABC (35 lb. ABC) / IS45ABC (45 lb. ABC) / Manufactured by: AMEREX

More information

5.07 Air Replenishment Systems

5.07 Air Replenishment Systems 5.07 Air Replenishment Systems Reference: 2010 SFFC, Section 511.2 Definitions: CERTIFIED COMPRESSOR. A compressor used by a contractor for maintenance and testing of air replenishment systems that is

More information

NFPA Technical Committee on Hybrid (Water and Inert Gas) Fire Extinguishing Systems

NFPA Technical Committee on Hybrid (Water and Inert Gas) Fire Extinguishing Systems San Antonio, TX October 12-14, 2016 The following are the meeting minutes from the third meeting of the Technical Committee on Hybrid (Water and Inert Gas) Fire Extinguishing Systems held in San Antonio,

More information

ISO INTERNATIONAL STANDARD. Ships and marine technology Fire-extinguishing systems for protection of galley cooking equipment

ISO INTERNATIONAL STANDARD. Ships and marine technology Fire-extinguishing systems for protection of galley cooking equipment INTERNATIONAL STANDARD ISO 15371 Second edition 2009-03-15 Ships and marine technology Fire-extinguishing systems for protection of galley cooking equipment Navires et technologie maritime Systèmes d'extinction

More information

Design & Construction Standards, Revised January

Design & Construction Standards, Revised January PART 1 GENERAL 1.01 Scope of Standard A. This standard provides general requirements of The University of Texas at Austin for fire-extinguishing systems other than water-based fire suppression systems.

More information

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS Introduction When properly installed and maintained, automatic fire sprinkler systems have proven to be the most effective means for protecting life and

More information

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code Part 1 - GENERAL 1.1 DESCRIPTION OF WORK A. Design and installation of an engineered Kidde ECS Advanced Delivery Systems (ADS), clean agent/waterless fire suppression system employing 3M Novec 1230 waterless

More information

Ships and marine technology Fireextinguishing. of galley cooking equipment

Ships and marine technology Fireextinguishing. of galley cooking equipment INTERNATIONAL STANDARD ISO 15371 Third edition 2015-11-15 Ships and marine technology Fireextinguishing systems for protection of galley cooking equipment Navires et technologie maritime Systèmes d extinction

More information

S a n F r a n c i s c o F i r e D e p a r t m e n t B u r e a u o f F i r e P r e v e n t i o n & I n v e s t i g a t i o n 1 of 8 P a g e

S a n F r a n c i s c o F i r e D e p a r t m e n t B u r e a u o f F i r e P r e v e n t i o n & I n v e s t i g a t i o n 1 of 8 P a g e 5.07 Air Replenishment Systems (2016) Reference: SFFC, Section 511.2. Purpose: The purpose of this bulletin is to describe the requirements for air replenishment systems intended to be used to fill firefighters'

More information

Bold items are particular to the City of Euless

Bold items are particular to the City of Euless EULESS FIRE DEPARTMENT FIRE MARSHAL S OFFICE INFORMATION LINE: Revised 8/2004 Fire Chief Lee Koontz Fire Marshal Paul Smith EFD-FMO 3-1 2003 International Fire & Building Code as Amended NFPA Standards

More information

CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300

CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300 CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300 FREQUENTLY ASKED QUESTIONS CONCERNING COMMERCIAL COOKING PROTECTION Published by FIRE ENGINEERING DIVISION

More information

Hospitals and Major Medical Centers

Hospitals and Major Medical Centers Hospitals and Major Medical Centers INERGEN Fire Suppression Systems AUTOPULSE Detection and Control Equipment SENTRY Hand Portable Fire Extinguishers Medical centers have special concerns for fire safety

More information

Iowa State Fire Marshal

Iowa State Fire Marshal Iowa State Fire Marshal LIFE SAFETY CODE REQUIREMENTS LONG TERM CARE Kyle R. Gorsh, Special Agent in Charge Iowa Department of Public Safety State Fire Marshal Division 2012 LSC & Applicable Standards

More information

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE FOAM FIRE EXTINGUISHERS MODEL 254-6 LITER AFFF FOAM WITH SPRAY NOZZLE Model 250 2 ½ GAL.LON AFFF FOAM WITH ASPIRATED NOZZLE MODEL 252 2 ½ GAL.LON FFFP (ALCOHOL RESISTANT) FOAM WITH ASPIRATED NOZZLE OWNER'S

More information

D. Reference Standards (Utilize latest editions available):

D. Reference Standards (Utilize latest editions available): 1.01 Scope of Standard A. This standard provides general requirements of The Sam Houston State University for fireextinguishing systems other than water-based fire suppression systems. This document is

More information

TECHNICAL COMMITTEE ON SAFETY AT MOTORSPORTS VENUES. NFPA 610 First Draft Meeting. October 17-18, 2016

TECHNICAL COMMITTEE ON SAFETY AT MOTORSPORTS VENUES. NFPA 610 First Draft Meeting. October 17-18, 2016 TECHNICAL COMMITTEE ON SAFETY AT MOTORSPORTS VENUES NFPA 610 First Draft Meeting October 17-18, 2016 Westin Kansas City at Crown Center 1 East Pershing Road Kansas City, MO, 64108 Conference Call Access:

More information

MEMORANDUM. NFPA 51 First Draft Technical Committee FINAL Ballot Results (A2017 Cycle)

MEMORANDUM. NFPA 51 First Draft Technical Committee FINAL Ballot Results (A2017 Cycle) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: Technical Committee on Industrial and Medical Gases

More information

Data/ Specification Sheet

Data/ Specification Sheet Data/ Specification Sheet MONARCH Dry Chemical Automotive Paint Spray Booth Fire Suppression System TM 1. Fixed temperature mechanical or thermal detectors 2. Electrical conduit protecting stainless steel

More information

NFPA 550 ROP Meeting Minutes

NFPA 550 ROP Meeting Minutes NFPA 550 ROP Meeting Minutes NFPA Technical Committee on Fire Risk Assessment Methods (FIR-AAA) June 24, 2010 Microsoft Live Meeting 1. Call to order. The meeting was called to order at 1:00 PM on Monday,

More information

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Rancho Cucamonga Fire Protection District Prevention Bureau Standard Rancho Cucamonga Fire Protection District Prevention Bureau Standard Title: Fire Alarm and Monitoring Systems Standard # 9-3 Effective: May 2002 Number of Pages: 7 Updated: December 2016 for consistency

More information

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL NO. 05602 FOR AMEREX STORED PRESSURE, HAND PORTABLE DRY CHEMICAL FIRE EXTINGUISHERS. ABC (Ammonium Phosphate Base)

More information

Revised March 2015 Fire Alarm Systems Verification. Schedule I(A) Services. *Manditory Site visit required*

Revised March 2015 Fire Alarm Systems Verification. Schedule I(A) Services. *Manditory Site visit required* 1.0 Description of Services Required: Revised March 2015 Fire Alarm Systems Verification Schedule I(A) Services *Manditory Site visit required* Perform the annual fire alarm system and sprinkler system

More information

Changes in NFPA

Changes in NFPA Changes in NFPA 72-2002 2002 Oregon Fire Code Committee November 25, 2003 Michael B. Baker, SET Automatic Fire Alarm Association MikeBaker@afaa.org 2003 Michael B. Baker 1 Table of Contents 1. Administration

More information

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK STRIKE FIRST CORPORATION AKC SERVICE MANUAL (v1) UL / ULC WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK All fire extinguishers should be installed, inspected

More information

Understanding, Applying and Enforcing NFPA 25. James D. Lake NFSA Director of Training

Understanding, Applying and Enforcing NFPA 25. James D. Lake NFSA Director of Training Understanding, Applying and Enforcing NFPA 25 James D. Lake NFSA Director of Training When Sprinklers Are Ineffective Water did not reach fire 8% 7% 7% 5% 44% Not enough water released Damaged Component

More information

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES SHIPPING NOTICE Maritime Authority of the Cayman Islands Head Office 3 rd Floor, Government Administration Building, 133 Elgin Avenue PO Box 2256, Grand Cayman, KY1-1107, Cayman Islands Tel: +1 345 949

More information

Model Policy On Portable Fire Extinguishers (Ontario Version)

Model Policy On Portable Fire Extinguishers (Ontario Version) Model Policy On Portable Fire Extinguishers (Ontario Version) Every workplace needs a policy ensuring the appropriate selection, use, storage and maintenance of fire extinguishers. OHS managers in any

More information

2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7

2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7 WET SPRINKLER Monthly Wet Sprinkler 2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7 VISUALS [per NFPA 25-1998 ed] 1. Gauge (Ck for Condition, Normal Pressure) [per 2-2.4.1] 2. Valves

More information

APPENDIX H (DESIGN SUBMISSION CRITERIA)

APPENDIX H (DESIGN SUBMISSION CRITERIA) APPENDIX H (DESIGN SUBMISSION CRITERIA) FIRE ALARM SYSTEM As per ACCORD standard Part 5, section 5.7 Fire Alarm System Design to be verified by ACCORD Chief Safety Inspector. Testing of the installation

More information

Committee Input No. 9-NFPA [ Global Input ] Supplemental Information. Submitter Information Verification. Committee Statement

Committee Input No. 9-NFPA [ Global Input ] Supplemental Information. Submitter Information Verification. Committee Statement Committee Input No. 9-NFPA 2001-2016 [ Global Input ] Incorporate revisions per the attached file. Supplemental Information File Name 2001-CI_9.pdf Description Data and specific revisions presented at

More information

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment February 2017 Alberta Fire Code safety equipment maintenance requirements: The Black Diamond Fire Department has

More information

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions. 11/16/12 TerraView First Revision No. 15-NFPA 720-2012 [ Global Input ] Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

More information

Report on Proposals F2007 Copyright, NFPA Report of the Committee on Dry and Wet Chemical Extinguishing Systems

Report on Proposals F2007 Copyright, NFPA Report of the Committee on Dry and Wet Chemical Extinguishing Systems Report of the Committee on Dry and Wet Chemical Extinguishing Systems Edward J. Kaminski, Chair Schirmer Engineering Corporation, NV [I] Paul E. Buchhofer, Building Inspection Underwriters, Inc., PA [E]

More information

Technical Committee on Fluidized Bed Boilers

Technical Committee on Fluidized Bed Boilers Technical on Fluidized Bed Boilers AGENDA Web/Teleconference 1. Chair s welcome, call to order, and opening remarks at 1:00 pm EST. 2. Self-Introduction of Members and Guests 3. Approval of Minutes from

More information

The Technical Committee on Commissioning and Integrated Testing

The Technical Committee on Commissioning and Integrated Testing National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org TO: FROM: The Technical Committee on Commissioning and Integrated Testing

More information

Introductions made by the Chair, committee members, NFPA Staff Liaison, Jacqueline Wilmot and Dan Gorham of the Fire Protection Research Foundation.

Introductions made by the Chair, committee members, NFPA Staff Liaison, Jacqueline Wilmot and Dan Gorham of the Fire Protection Research Foundation. NFPA Technical Committee On Fire Hose NFPA 1961 Minutes Task Group Update Underwriters Laboratory November 15 th - 16 th 2016 Tuesday, November 15 th, 2016 Meeting called to order at 8:07 AM by Chairman

More information

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System 1. GENERAL 1.1 INTENT OF SPECIFICATIONS A. This specification details the requirements for an engineered inert gas fire suppression system Model Kidde Nitrogen. These requirements, combined with good engineering

More information

NEW YORK CITY FIRE DEPARTMENT. Notice of Public Hearing and Opportunity to Comment on Proposed Rule

NEW YORK CITY FIRE DEPARTMENT. Notice of Public Hearing and Opportunity to Comment on Proposed Rule NEW YORK CITY FIRE DEPARTMENT Notice of Public Hearing and Opportunity to Comment on Proposed Rule What are we proposing? The Fire Department is proposing to comprehensively update Section 3004-01 of Title

More information

THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS.

THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS. THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS. IF YOU RECEIVED A NOTICE BY MAIL AND YOU DO NOT CURRENTLY HAVE A FIRE ALARM INSTALLED IN YOUR BUILDING, YOU MAY DISREGARD THE NOTICE. Dear Building

More information

NFPA 17A. Standard for Wet Chemical Extinguishing Systems Edition {016E4141-A B736-7D }

NFPA 17A. Standard for Wet Chemical Extinguishing Systems Edition {016E4141-A B736-7D } NFPA 17A Standard for Wet Chemical Extinguishing Systems Customer ID 63459974 NFPA, 1 Batterymarch Park, Quincy, MA 02169-7471 An International Codes and Standards Organization IMPORTANT NOTICES AND DISCLAIMERS

More information

BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT

BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT Guidance and Instructions for Ship-owners, Managers, Masters, Bahamas Recognised Organisations and Bahamas Approved Nautical Inspectors Note: This

More information

Proposed Changes to NFPA

Proposed Changes to NFPA 2017 NFPA Conference & Expo Proposed Changes to NFPA 72-2019 Presented by: Manuelita David (SIG-FUN), Jensen Hughes Warren Olsen (SIG-SSS), Fire Safety Consultants, Inc. Merton Bunker (SIG-AAC), EYP Architecture

More information

System Test Report CLEAN AGENT

System Test Report CLEAN AGENT City of Black Hawk Fire Department 196 Clear Creek Street PO Box 68 Black Hawk, CO 80422-068 Office 303-582-0426 Fax 303-582-2229 www.cityofblackhawk.org System Test Report CLEAN AGENT Occupancy Information

More information

ARKANSAS FIRE PROTECTION LICENSING BOARD ACT 743 OF 1977

ARKANSAS FIRE PROTECTION LICENSING BOARD ACT 743 OF 1977 ARKANSAS FIRE PROTECTION LICENSING BOARD ACT 743 OF 1977 As Amended July 1, 1999 20-22-601. LEGISLATIVE INTENT FIRE PROTECTION LICENSING BOARD It is the purpose and intent of this subchapter to provide

More information

Hydrostatic Retest Requirements for ANSUL Pressure Vessels

Hydrostatic Retest Requirements for ANSUL Pressure Vessels TECHNICAL BULLETIN Hydrostatic Retest Requirements for ANSUL Pressure Vessels Portables, Wheeled Units, and Pre-engineered Pressure Vessels One Stanton Street Marinette, WI 54143-2542, USA +1-715-735-7411

More information

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE EXTINGUISHERS TABLE OF CONTENTS

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE EXTINGUISHERS TABLE OF CONTENTS RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER 0780-02-14 FIRE EXTINGUISHERS TABLE OF CONTENTS 0780-02-14-.01 Definitions 0780-02-14-.09 Restrictions 0780-02-14-.02 Standards

More information

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item Public Comment No. 23-NFPA 96-2015 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM E84, Standard Test Method

More information

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements Module 3 Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements 1 WATER-BASED SUPPRESSION SYSTEMS-PART TWO This module covers: 1. Ohio Building Code requirements and when and why

More information

TECHNICAL COMMITTEE ON FIRE CODE

TECHNICAL COMMITTEE ON FIRE CODE TECHNICAL COMMITTEE ON FIRE CODE M E M O R A N D U M TO: FROM: Technical Committee on Fire Code (FCC-AAA) Gregory Harrington, P.E., Staff Liaison DATE: February 3, 2011 SUBJECT: NFPA 1124 Amended CP#2

More information

Correlating Committee on Automatic Sprinkler Systems

Correlating Committee on Automatic Sprinkler Systems Correlating Committee on Automatic Sprinkler Systems M E M O R A N D U M DATE: May 14, 2014 TO: FROM: Principal and Alternate Members of the Correlating Committee on Automatic Sprinkler Systems Matt Klaus,

More information

*** Inspection *** Please identify yourself as a Cintas representative when arriving onsite.

*** Inspection *** Please identify yourself as a Cintas representative when arriving onsite. Tech Clock-In/Out IVR: 1-877-349-2906 Job #: Tech ID #: 2902 FP Service Instructions Job #: *** Inspection *** You must clock in and out of this job through Cintas's IVR phone system! Call 1-877-349-2906

More information

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS SECTION 1 GENERAL SPECIFICATIONS I. SCOPE This specification outlines the requirements for a pre-engineered

More information

Public Safety [661] Chapter 226, Liquefied Petroleum Gas, Amended for Application within the State of Iowa

Public Safety [661] Chapter 226, Liquefied Petroleum Gas, Amended for Application within the State of Iowa Public Safety [661] Chapter 226, Liquefied Petroleum Gas, Pursuant to the authority of Iowa Code section 101.1, the State Fire Marshal hereby adopts new Chapter 226, Liquefied Petroleum Gas, Iowa Administrative

More information

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input of 280 2/6/2015 12:06 PM Public Input No. 1-NFPA 58-2013 [ Global Input ] NOTE: This public input originates from Tentative Interim Amendment 58-14-1 (TIA 1079) issued by the Standards Council on August

More information

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS INTERNATIONAL MARITIME ORGANIZATION E IMO ASSEMBLY 23rd session Agenda item 17 A 23/Res.951 25 February 2004 Original: ENGLISH Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED

More information

Preliminary Agenda Technical Committee on Liquefied Petroleum Gas

Preliminary Agenda Technical Committee on Liquefied Petroleum Gas Preliminary Agenda Technical Committee on Liquefied Petroleum Gas Tuesday, March 10; All Day Wednesday, March 11; All Day DRURY PLAZA HOTEL San Antonio Riverwalk 0. Administrative. A. Meeting Schedule.

More information

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures Please note this is not an all-inclusive list. The type and complexity of your project

More information

REPORT OF THE NFPA MOTIONS COMMITTEE* ON FALL 2013 REVISION CYCLE STANDARDS

REPORT OF THE NFPA MOTIONS COMMITTEE* ON FALL 2013 REVISION CYCLE STANDARDS REPORT OF THE NFPA MOTIONS COMMITTEE* ON FALL 2013 REVISION CYCLE STANDARDS I. Introduction. This is the Motions Committee Report on Standards in the Fall 2013 Revision Cycle. The report identifies Certified

More information

GENERAL BULLETIN NO. 5397

GENERAL BULLETIN NO. 5397 ANSUL INCORPORATED ONE STANTON STREET MARINETTE, WI 54143-2542 715-735-7411 www.ansul.com GENERAL BULLETIN NO. 5397 DATE: August 20, 2008 TO: FROM: SUBJECT: All Authorized ANSUL Vehicle System s Distributors

More information

Twin-Agent Fire Fighting/Securing Systems Specifications

Twin-Agent Fire Fighting/Securing Systems Specifications Twin-Agent Fire Fighting/Securing Systems Specifications Models 450/50, 450/100, 900/100 & 1350/200 INDEX 1.0 GENERAL 1.1 References 1.2 Submittals 1.3 System Capabilities 1.4 Quality Control 1.5 Warranty,

More information

MERAMEC VALLEY R-III SCHOOL DISTRICT 126 North Payne Street Pacific, MO

MERAMEC VALLEY R-III SCHOOL DISTRICT 126 North Payne Street Pacific, MO MERAMEC VALLEY R-III SCHOOL DISTRICT 126 North Payne Street Pacific, MO 63069 636-271-1400 REQUEST FOR PROPOSAL FIRE EXTINGUISHER/KITCHEN HOOD INSPECTIONS FOR ADDITIONAL INFORMATION CONTACT: Joel Cracchiolo,

More information

All temporary special events held within the City of Orlando must be approved and inspected by the Orlando Fire Department prior to holding the event.

All temporary special events held within the City of Orlando must be approved and inspected by the Orlando Fire Department prior to holding the event. December 15, 2005 Dear Event Planner: All temporary special events held within the City of Orlando must be approved and inspected by the Orlando Fire Department prior to holding the event. Applications

More information

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course Florida Building Code 2010 Chapter 9 Fire Protection Systems Advanced Course 1 Introduction This course will cover specific sections of Chapter 9 that relate to fire alarm systems. While many contractors

More information

M E M O R A N D U M. Technical Committee on Supervising Station Fire Alarm and Signaling Systems

M E M O R A N D U M. Technical Committee on Supervising Station Fire Alarm and Signaling Systems National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Supervising Station

More information

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE To: From: Subject: Whom It May Concern Carl Ray Austerman, Fire Marshal Contractor s Guide Welcome to the Glendale Fire Department s Contractors Guide. This

More information

12/21/2015 National Fire Protection Association Report

12/21/2015 National Fire Protection Association Report http://submittals.nfpa.org/terraviewweb/viewerpage.jsp?id=232 2012.ditamap&toc=false&draft=true 1/9 Public Comment No. 1 NFPA 232 2015 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents

More information

TECHNICAL COMMITTEE ON MANUFACTURE OF ORGANIC COATINGS First Draft Meeting Agenda March 19, :00 AM - 5:00 PM EST Web/Teleconference Meeting

TECHNICAL COMMITTEE ON MANUFACTURE OF ORGANIC COATINGS First Draft Meeting Agenda March 19, :00 AM - 5:00 PM EST Web/Teleconference Meeting TECHNICAL COMMITTEE ON MANUFACTURE OF ORGANIC COATINGS First Draft Meeting Agenda March 19, 2014 9:00 AM - 5:00 PM EST Web/Teleconference Meeting 1. Welcome. George Seuss, Chair 2. Introductions and Update

More information

Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference

Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference Matthews, Diane Subject: Location: Start: End: Show Time As: Recurrence: Meeting Status: Organizer: Required Attendees: Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference http://nfpa.adobeconnect.com/rpbmeet/

More information

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS ANSUL Twin-Agent Fire Fighting/Securing Systems Specifications Models 450/50-B, 450/100-B, 900/100-B INDEX 1.0 GENERAL 1.1 References 1.2 Submittals 1.3 System Capabilities 1.4 Quality Control 1.5 Warranty,

More information

PORTABLE FIRE EXTINGUISHERS

PORTABLE FIRE EXTINGUISHERS FIRE CODE BULLETIN February 2018 14-FCB-002 Page 1 of 6 PORTABLE FIRE EXTINGUISHERS PURPOSE This bulletin is to clarify the intent of the Alberta Fire Code 2014 (AFC 2014) and NFPA 10, Standard for Portable

More information

Service Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT

Service Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT 58 Fire protection equipment requires care and maintenance at scheduled intervals to assure it will operate properly and safely when needed. Only personnel who are trained and qualified to maintain the

More information

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE PROTECTION SPRINKLER SYSTEM CONTRACTORS

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE PROTECTION SPRINKLER SYSTEM CONTRACTORS RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER 0780-02-07 FIRE PROTECTION SPRINKLER SYSTEM CONTRACTORS TABLE OF CONTENTS 0780-02-07-.01 Definitions 0780-02-07-.08 Installation,

More information

SOMERSWORTH CODE FIRE PREVENTION AND LIFE SAFETY CHAPTER 21

SOMERSWORTH CODE FIRE PREVENTION AND LIFE SAFETY CHAPTER 21 SOMERSWORTH CODE FIRE PREVENTION AND LIFE SAFETY CHAPTER 21 ARTICLE I FIRE PREVENTION CODE 21-1. Statutory authority 21-2. Adoption of standards 21-3. Definitions 21-4. Exceptions to Fire Prevention Code

More information

Western Michigan University Facilities Management Engineering Division

Western Michigan University Facilities Management Engineering Division Western Michigan University Facilities Management Engineering Division Design Guidelines for Facilities Construction: DESIGN GUIDELINE DG21-1 Fire Suppression Systems & Equipment I. GENERAL... 1 A. General

More information

Chapter 4: Fire Protection Systems

Chapter 4: Fire Protection Systems Chapter 4: Fire Protection Systems Automatic Extinguishing Systems (Fire Sprinklers) One of the most important aspects of a storage warehouse inspection is ensuring that the automatic extinguishing system

More information

HIGH-RISE RETROFIT ORDINANCES - NO and NO

HIGH-RISE RETROFIT ORDINANCES - NO and NO INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LAMC 91.8604 Effective: 9-06-90 DOCUMENT NO. P/BC 2002-054 Revised: 4-15-03 Previously Issued As: MGD 88 HIGH-RISE RETROFIT ORDINANCES - NO.

More information

FM-200 In-Cabinet Series

FM-200 In-Cabinet Series 1. GENERAL SPECIFICATION 1.1 A total flooding, In-Cabinet fire suppression system, employing FM-200 superpressurized with dry nitrogen shall be installed to meet a minimum design concentration of %, by

More information

Winnipeg Fire Department Fire Prevention Branch

Winnipeg Fire Department Fire Prevention Branch Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of

More information

FIre Extinguishers. K-GUARD Wet Chemical Fire Extinguishers Manual INSTALLATION 2014-DEC-29 REV. 03 PAGE 1 EXTINGUISHERS

FIre Extinguishers. K-GUARD Wet Chemical Fire Extinguishers Manual INSTALLATION 2014-DEC-29 REV. 03 PAGE 1 EXTINGUISHERS K-GUARD Wet Chemical K-GUARD K-Guard WET CHEMICAL Wet Chemical EXTINGUISHERS FIre Extinguishers INSTALLATION 2014-DEC-29 REV. 03 PAGE 1 Installation, OPERATION, Recharge, and Maintenance Manual 004327

More information

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle)

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle) M E M O R A N D U M TO: FROM: NFPA Technical Committee on Alternative Approaches to Life Safety Linda MacKay DATE: December 28, 2010 SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle) The ROP letter

More information

WHEELED STORED PRESSURE

WHEELED STORED PRESSURE OWNERS SERVICE MANUAL NO. 19795 INSTALLATION, OPERATING & SERVICING INSTRUCTIONS All fire extinguishers should be installed, inspected and maintained in accordance with the National Fire Protection Association

More information

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement 1 of 7 3/4/2016 12:02 PM Second Revision No. 5-NFPA 56-2016 [ Section No. 1.1.2 ] 1.1.2 Nonapplication of Standard. This standard shall not apply to the following items: (1)* Piping systems covered by

More information

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual 008094 All fire extinguishers should be installed, inspected and maintained in accordance with

More information

TOTALPAC2 Integrated Fire Protection System

TOTALPAC2 Integrated Fire Protection System TOTALPAC2 Integrated Fire Protection System Page 1 of 8 General 1. Applicable Standards The TOTALPAC2 Surefire complies with the following standards: - NFPA-13 Sprinkler Systems; - NFPA-15 Water Spray

More information

GUILFORD COUNTY SCHOOLS

GUILFORD COUNTY SCHOOLS GUILFORD COUNTY SCHOOLS Fire Extinguisher Plan Policy In accordance with the regulations established by the United States Department of Labor pursuant to the Occupational Safety and Health Act and the

More information

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M To: From: NFPA Technical Committee on Helicopter Facilities

More information

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER The 2016 Denver Building and Fire Code includes the following codes except as amendment herein. 2015 IBC (Building) 2015 IFC (Fire)

More information

HYDROSTATIC TEST INSTRUCTIONS

HYDROSTATIC TEST INSTRUCTIONS HYDROSTATIC TEST INSTRUCTIONS STORED PRESSURE PORTABLE FIRE EXTINGUISHERS One Stanton Street / Marinette, WI 54143-2542, USA / +1-715-735-7411 Copyright 2017 Tyco Fire Products LP. All rights reserved.

More information

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ]

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ] Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard and shall be considered

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 21 0800 - COMMISSIONING OF FIRE SUPPRESSION SYSTEMS GENERAL 1.1 SUMMARY General 1. Work under this contract shall meet the requirements of Division 01, General Requirements, Conditions of Contract,

More information

Standard Procedure s for Tenant Fire Sprinkler Work

Standard Procedure s for Tenant Fire Sprinkler Work Standard Procedure s for Tenant Fire Sprinkler Work 1. Provide tenant a copy of Simon Property Group Standards for Fire Protection Systems, Section 15400, requesting they in turn would give the standards

More information