Emergency call system for lifts: SafeLine SLMX2 Quick-guide
|
|
- Willa Hodge
- 5 years ago
- Views:
Transcription
1 Emergency call system for lifts: SafeLine SLMX2 Quick-guide
2 Introduction SAFELINE SL Introduction General notes The SAFELINE SL system has been designed and manufactured in accordance with the best available techniques and trusted safety technology specifi cations. These mounting instructions must be observed by all persons mounting, maintaining or confi guring the SAFELINE SL. These mounting instructions must be available to the qualifi ed service engineer or maintenance staff at all times. A thorough knowledge of the essential and specifi c safety instructions applying to materials handling technology in general and to lift technology in particular is a prerequisite for a correct and safe handling and a reliable trouble-free functioning of the system. The SAFELINE SL must be exclusively used for the intended purpose. Any modifi cation of or extension to the SAFELINE SL or the individual components of the SAFELINE SL by the system owner are not authorised. Liability exclusion The manufacturer is not liable with regard to the buyer of the product or third parties for damages, losses, expenses or expenditures incurred by the buyer or third parties as a result of accidents, abuse of the product, false mounting or unauthorized alterations, repairs or extensions. In every one of these cases, any guarantee claim will be excluded. The technical data are completely up-to-date. Typographical errors, errors and technical modifi cations reserved. The manufacturer K. A. Schmersal GmbH Industrial safety switching appliances Möddinghofe 30 D Wuppertal Phone (0) Fax (0) info@schmersal.com Internet 2
3 Introduction For your personal safety These mounting instructions include important safety instructions as well as the necessary information for a proper fi tting of the SAFELINE SLMX2. Please read these mounting instructions attentively. The applicable prescriptions of the Professional Federation, the Association of Electricians and Electrical Engineers, the EC Directives and the General Regulations on Industrial Safety must be observed. The service engineer must know the essential requirements regarding Safety at Work and Accident Prevention; he furthermore must be trained in the functioning and operation of lifts and transport installations. The service engineer must be an electric specialist and technician in accordance with EN Before starting the mounting of the SAFELINE SLMX2, the lift must be protected against unauthorized switching-on by third parties. Install on every fl oor a sign labelled: Caution! Lift out of order. Maintenance works! Risk of falling! Close the landing doors of the lift cage during mounting. Delimitate hazardous areas. Only use fi tting and maintenance tools and equipment in perfect condition. 3
4 Wiring diagram Connections Orange/White Voltage supply 0 Volt Orange Green/White + IN CASE OF ALARM Voltage supply Volt Additional input (fi lter) Blue + IN CASE OF ALARM Alarm button Blue/White Green Telephone line out to next SL Brown/White Brown Telephone line in Series-wiring of max. 9 SLMX2/SL3000 units Four wires required Telephone TELELINJE line inin Braun Brown Braun Brown / / Weiß White Blau / Weiß Blue / White Grün Green Braun Brown Braun Brown / / Weiß White Blau / Weiß Blue / White Grün Braun Braun / Weiß Green Brown Brown / White Parallel-wiring of max. 3 SLMX2/SL3000 units Two wires required Telephone TELELINJE line IN in Brown Braun Braun Brown / Weiß / White Brown Braun Braun Brown / Weiß / White Brown Braun Braun Brown / Weiß / White 4
5 Programming codes Programming code Access code, then you can start programming Function Code Note Set alarm code for P100 ID code * 0 1 * For the P100 ID code, you always must enter 8 digits; fi nish with # CPC ID code * 0 2 * For the CPC ID code, you always must enter 6-8 digits; fi nish with # Q23 ID code * 0 3 * For the Q23 ID code, you always must enter 12 digits; fi nish with # Enter telephone number: 1 st telephone number * 1 1 * For the telephone number, you can enter 1-16 digits; fi nish with # 2 nd telephone number * 1 2 * For the telephone number, you can enter 1-16 digits; fi nish with # 3 rd telephone number * 1 3 * For the telephone number, you can enter 1-16 digits; fi nish with # 4 th telephone number * 1 4 * For the telephone number, you can enter 1-16 digits; fi nish with # Call type: Call type 1 st telephone number * 2 1 * Enter the code (0-3) and fi nish with # 0 = P100 1 = Voice 2 = Q23 3 = CPC Call type 2 nd telephone number * 2 2 * Enter the code (0-3) and fi nish with # 0 = P100 1 = Voice 2 = Q23 3 = CPC Call type 3 rd telephone number * 2 3 * Enter the code (0-3) and fi nish with # 0 = P100 1 = Voice 2 = Q23 3 = CPC Call type 4 th telephone number * 2 4 * Enter the code (0-3) and fi nish with # 0 = P100 1 = Voice 2 = Q23 3 = CPC Call type LMS * 3 0 * Enter the code (0 of 3) and fi nish with # 0 = P100 3 = CPC Call type self test * 3 1 * 0 # P100 is used for test alarms. Self test alarm: LMS telephone number * 1 6 * Enter the LMS telephone number of the alarm receiver/slcc, fi nish with # Self test alarm * 1 7 * Enter the telephone number of the test alarm receiver, fi nish with # Test interval * 2 7 * Enter the interval for the test alarm in days (0-99) in, fi nish with # Alarm type (only when the call type is CPC): 1 st telephone number * 4 1 * Enter the alarm type, fi nish with #. Default setting = 10 2 nd telephone number * 4 2 * Enter the alarm type, fi nish with #. Default setting = 10 3 rd telephone number * 4 3 * Enter the alarm type, fi nish with #. Default setting = 10 4 th telephone number * 4 4 * Enter the alarm type, fi nish with #. Default setting = 10 LMS number * 4 5 * Enter the alarm type, fi nish with #. Default setting = 17 Number self test alarm * 4 6 * Enter the alarm type, fi nish with #. Default setting = 26 Recording voice messages: Record an emergency call * 5 1 * «Message» # This message is played in the lift car. Record an emergency call/alarm message from the lift car Options for the recorded voice messages: * 5 2 * «Message» # This message is played to the operator answering the emergency call. Options for the emergency call * 6 1 * Enter the number of the desired option and fi nish with # 0 = deactivate the recorded voice message 1 = activate the recorded voice message # = play the recorded voice message Options for the emergency call/alarm message from the lift car * 6 2 * Enter the number of the desired option and fi nish with # 0 = deactivate the recorded voice message 1 = activate the recorded voice message # = play the recorded voice message Quit programming mode 5
6 Programming codes Programming code Access code, then you can start programming Function Code Note Other codes: Time-out redial rings * 7 2 * Choose 02-50, fi nish with #. Default setting = 08 Function additional input * 7 3 * Choose 0-2, fi nish with # 0 = none 1 = fi lter input 2 = LMS input Additional input type * 7 4 * Choose 0-1, fi nish with # 0 = normally-open contact (NO) 1 = normally-closed contact (NC) Hotline * 7 5 * Choose 0-1, fi nish with # 0 = default telephone (default setting) 1 = hotline Compatibility mode * 7 7 * Choose 0-1, fi nish with # 0 = off 1 = Kone Display mode * 7 8 * Choose 0-1, fi nish with # 0 = default 1 = completely to EN81-28 Reset active alarm * 8 0 * Choose 0-1, fi nish with # 0 = off (default setting) 1 = on Automatic answer * 8 1 * Choose 0-16, fi nish with # 00 = do not answer 02 = default setting Unit number * 8 2 * Choose 0-9, fi nish with #. 0 = default setting Detect dial tone * 8 3 * Choose 0-1, fi nish with # 0 = off 1 = on Return signal to SLCC * 8 4 * Choose 0-2, fi nish with # 0 = do not send return signal (default setting) 1 = send return signal 2 = send start and end message Cancel in case of new alarm * 8 6 * Choose 0-1, fi nish with # 0 = off 1 = on (default setting) Alarm button delay * 8 7 * Choose 0-60, fi nish with #. Default setting = 5 Relay output type * 8 8 * Choose 0-5, fi nish with # 0 = default 1 = EN = DTMF-controlled Alarm button type * 8 9 * Choose 0-1, fi nish with # 0 = normally-open contact (NO) 1 = normally-closed contact (NC) Change password * 9 1 * Enter four digits, fi nish with #. Default setting = 0000 Simulate alarm * 9 4 * Choose 1-5, fi nish with # Quit programming mode and send an emergency call Note! The LMS telephone number *16* must be programmed! 1 = emergency call 2 = test alarm 3 = alarm battery failure 4 = alarm microphone/loudspeaker failure 5 = return signal in case of voice communication Quit programming * 0 0 * # Quit programming mode Restore factory settings * 9 9 * 1 # Reactivate the factory settings of the unit 6 Quit programming mode
7 LED s Yellow LED: Flashes once every 5 seconds - Telephone line not OK (!) Off - Telephone line OK, call terminated Flashes twice every second - Alarm button active. Permanently on - Alarm activated. Green LED: Flashes once every 5 seconds - Unit OK (!) Flashes twice every second - Alarm fi lter/fi lter input activated (!) Flashes rapidly - Confi guration mode. Permanently on - Call forwarded. Off - Telephone line not OK (!) System LED: Flashes once every 5 seconds - Telephone line OK. Flashes twice every 5 seconds - no telephone connection available Flashes every 0.5 seconds - Call forward in progress. Permanently on - Call forwarded. Flashes rapidly - incoming call System LED Note! The functions marked with (!) are disabled, when the function Display mode is set to Entirely to EN
8 K.A. Schmersal GmbH Industrielle Sicherheitsschaltsysteme Möddinghofe 30 D Wuppertal Postfach D Wuppertal Telefon (0) Telefax (0) info@schmersal.com Internet / HE / / English
Memcom Emergency Telephone
Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming
More informationGSM RFID VOICE Alarm System
GSM RFID VOICE Alarm System User s Manual For a better understanding of this product, please read this user manual thoroughly before using it. CONTENTS [Function Instruction] [Control Panel] Control Panel
More informationOperating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content
8 Appendix 8.1 Wiring examples...4 8.2 Start configuration...4 8.3 Sensor configuration...4 8.4 Actuator configuration...5 Operating instructions.............pages 1 to 6 Original 9 EU Declaration of conformity
More informationRemote alarm unit Art. Nr.:
Art. Nr.: 0814.. Product features Indication and transmission of alarms, malfunctions, battery status for all programmed alarm detectors Remote alarm programming of up to 20 alarm detectors Function monitoring
More informationSafeLine OCC MANUAL. SafeLine Product 121,6 59,25 22,1. Otis Connection Cabeling. Option for installing SafeLine on an Otis REM5 equipped lift.
SafeLine OCC MANUAL 121,6 59,25 22,1 Otis Connection Cabeling. Option for installing SafeLine on an Otis REM5 equipped lift. SafeLine Product 02.2017 www.safeline-group.com Table of contents INTRODUCTION
More informationAutomatic Phone-Out Home Monitoring Systems
Automatic Phone-Out Home Monitoring Systems Power Outage, Freeze and Flood Alarm Product Description Model Number: THP201 These monitoring systems are intended to monitor homes, cabins, and other premises
More informationPERMACONN PM1030 Includes DI300. Installation Manual
PERMACONN PM1030 Includes DI300 Installation Manual Radio Data Comms Unit 5/20-30 Stubbs Street Silverwater NSW 2128 Telephone: 02 9352 1777 Facsimile: 02 9352 1700 Introduction The PERMACONN system provides
More informationEncontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.
TV8S 521 1 About this document Operating instructions... pages 1 to 6 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information you
More informationHELPY QUICK-TL GSM INTL
Alarm system for elevators HELPY QUICK-TL GSM INTL QUICK GUIDE 04/02/16 DESCRIPTION A B C D E F G H I L M N O Connector for external LEDs Connector for built-in loudspeaker Built-in loudspeaker Connector
More information2000 Series. Program Entry Guide. Control Panels
2000 Series EN Program Entry Guide Control Panels 2000 Series Program Entry Guide About This Manual EN 2 About This Manual This guide describes the programming parameters available to the 2000 Series Control
More information385 SERIES REMOTE HANDHELD SIREN ETSA385HR
! WARNING Sirens produce loud sounds that may damage hearing: - Roll up windows. - Wear hearing protection. - Use only for emergency response. - Avoid exposure to siren sound outside of vehicle. Please
More informationAUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V
AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V 05/06/2018 DESCRIPTION Autodialer to be fitted behind the cop or on top of the car / retrofit. A Connector for Esse-ti power supply (12 Vdc) B Micro SD Card
More informationUser's Manual. and Warranty Information. ThyssenKrupp. ThyssenKrupp Access
LIMITED WARRANTY Limited Warranty: Subject to the limitations set forth below, THYSSENKRUPP ACCESS, 4001 East 138th Street, Grandview, Missouri 64030, warrants to the ORIGINAL PURCHASER ONLY that the Volant
More informationBENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.
BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice. via Florida Z.I. Valtesino - 63013 GROTTAMMARE (AP) - ITALY Installation and Quick guide: DUAL
More informationAD1000EN-1R configured to operate as a DG1000
AD1000EN-1R configured to operate as a DG1000 Install the Main Unit on top of the lift car and mount the Microphone in the COP. Mount the Plastic speaker box so the speaker holes align up with some holes
More informationMemcom + Emergency Telephone
Memcom + Emergency Telephone Installation Guide Ref No. 453 901AU (GB) Version 4 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based
More informationPart. Test System Weekly See Watch ~Test. Points
Part 1. Test System Weekly See Watch ~Test Points 2. 3. 4. 5. 6. 7. 8. Turn System Off Enter your passcode to turn the system off and silence alarms. Turn System All On Press 9 Exit Delay begins If Error
More informationWIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER
BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.
More informationPERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS
PERS-600 PERSONAL EMERGENCY REPORTING SYSTEM BY BY INSTALLATION & OPERATION INSTRUCTIONS (760) 8-7000 USA & Canada (800) -587 & (800) 9-0 Toll Free FAX (800) 68-0 www.linearcorp.com CONTENTS CONTROL AREA
More informationPipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder
Pipo Communications Model ST-888 DTMF ANI/ENI Display Decoder 1516 Cassil Place Hollywood, California 90028-7106 Phone: 323-466-5444 Fax: 323-466-1520 www.pipo.cc Manual # 68-9888 May 1, 2002 Rev. 5/02
More informationEA-MINI / EA-MINI-V. LEITRONIC AG Swiss Security Systems
4923 Table of contents Overview... 2 2 Applications... 3 2. Door-phone... 3 2.. Wiring... 3 2.2 Alarm dialler... 4 2.2. Wiring... 4 3 Mechanical fitting... 5 3. Retrofit solutions to existing elevators...
More informationALARM SYSTEM USER S MANUAL Rev
ALARM SYSTEM USER S MANUAL Rev.06 890-00011 Manufacturer: Viatron Electronics 3514 1st Street, St-Hubert (Quebec) Canada J3Y 8Y5 WARNINGS the warranty can be void if the Agri-Alert 2400 is used in a manner
More informationProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01
ProTalk Expander Operating Manual Model B1292 July 28, 2009 Rev. 1.01 TABLE OF CONTENTS 1. Introduction... 1 2. Installation... 2 2.1 Wiring Diagram... 3 3. Operations... 4 4. Programming (B1225 Mode)...
More informationQUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP
QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP PROGRAMMING STARTS Entering Installer mode If you want to get into program mode press followed by your installer code, default set to 000000
More informationBENTEL SECURITY srl reserves the right to modify the technical specifications of this product without prior notice.
BENTEL SECURITY srl reserves the right to modify the technical specifications of this product without prior notice. via Florida - Z.I. Valtesino - 63013 GROTTAMMARE (AP) - ITALY USER MANUAL: Digital communicator
More informationThe Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70
The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70 1. Identify the Equipment and carry out a Risk Assessment before installation AD1000EN- 1R Main Unit EN1 Speaker
More information636 and 646 Keypads. User s Manual
636 and 646 Keypads 636 646 User s Manual Table Of Contents Basic Operation... 2 Access Codes... 4 Arming & Disarming... 5 Panic Zones... 11 Key Access Programming... 12 Additional Features... 13 Trouble
More informationDohse Aquaristik GmbH & Co. KG. T-Control Pro. Item no Status: 03/2013. Dohse Aquaristik GmbH & Co. KG
Dohse Aquaristik GmbH & Co. KG www.dupla.com Using instructiontion T-Control Pro Item no. 80696 Status: 03/2013 Dohse Aquaristik GmbH & Co. KG www.dohse-aquaristik.com Table of contents 1. Introduction.............................................
More informationDigiPlus INSTRUCTION MANUAL
DigiPlus INSTRUCTION MANUAL Introduction DigiPlus DigiPlus is a converter for use with Digital Communicators (and Control Panels with built-in Digital Communicators) that use Fast Format DTMF signalling
More informationCC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom
CC880/LP880, SC8016 EN Operators Guide Solution-16, Solution-16 Safecom CC880/LP880, SC8016 Operators Guide EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch
More information1. Functions of GPS locator ETLOC-30S 3
Contents 1. Functions of GPS locator ETLOC-30S 3 1.1 Direct view of the vehicle position on the map 3 1.2 Vehicle security 3 1.2.1 Vehicle protection 3 1.2.1.1 GPS protection 3 1.2.1.2 GPS higher level
More informationVersion 1.03 January-2002 USER S MANUAL
Version 1.03 January-2002 1 USER S MANUAL 2 Version 1.03 January-2002 System Details CUSTOMER:...... PHONE:... FAX:... INSTALLED BY:...... PHONE:... FAX:... MAINTENANCE & SERVICE:...... PHONE:... FAX:...
More informationAV-3008 LED, SOL AV-3008 GSM (for LED keypads)
E a s y L o a d e r AV-3008 LED, SOL AV-3008 GSM (for LED keypads) Integrated Alarm Control panel & Communicator 8 zones SMS Enabled Installation and Operation Large Manual Version 1.10 Edition I This
More information1. User features of the GSM dialer
1. User features of the GSM dialer The JA60GSM dialer offers many useful features described in detail below. The installer should properly demonstrate the use of the system to the user after installation
More informationCEM-24 Series. Owner's Manual - Installation and Operating Instructions
CEM-24 Series Owner's Manual - Installation and Operating Instructions Rev. 6.4 01.10 Pipersville, PA 18947 USA Phone: (215) 766-1487 - Fax: (215) 766-1493 Email: support@scillc.com - www.scillc.com Please
More informationSK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.
SK642 WIRELESS WATER ALARM SYSTEM WITH AUTO DIALER OWNER'S MANUAL AND SET UP INSTRUCTIONS. Thank you for choosing Ideal Security s Wireless Water Alarm with Telephone Dialer. Please read through complete
More informationA1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor
A1UL PERS Personal Emergency Response System TABLE OF CONTENTS 1. READ THIS FIRST... 1 2. SYSTEM OVERVIEW.. 1 3. COMPONENTS 2 4. UNIT OPERATION! Standby Mode.. 3! Emergency Activation. 3! Answering Incoming
More informationQuick Installation Manual LED Touch Keypad Autodial Wireless Alarm System
Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System By shield4u http:// (Version 20110816) A. Alarm Understanding Away Disarm Home Emergency Function Signal Interpretation Buzzer
More informationPROTECT SRB 200EXi-1A
2 Installation up to zone 1/21 J S L1 0V X1 X3 S11 S12 S21 S22 Installation up to zone 2 A1 F1 F2 U B U EXi U i 0V S12 S22 X1 X3 K1 Logic K2 K1 K2 13 23 U EXi SRB 200EXi U B -1A U i K1 K2 PA PA A1 A2 13
More informationAGRI-ALERT 9600 ALARM SYSTEM USER MANUAL
AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL M 890-00279 rev. 14 K 895-00004 rev. 00 Manufacturer: Viatron Electronics 5200, Armand-Frappier St-Hubert (Quebec) Canada J3Z 1G5 WARNINGS The warranty can be void
More informationCALLTRONIC. Operating instructions. Telephone remote control for Eberspächer parking heaters.
CALLTRONIC Operating instructions. Telephone remote control for Eberspächer parking heaters. 22 1000 61 01 10.2008 Contents Introduction Dear Customer... Application... Operation and Adjustment Operation
More informationSirius Control Box 6130 LRIT
Sirius Control Box 6130 LRIT Long-Range Identification and Tracking Owner s & Installation Manual Version 1.12 - 2 - Sirius Control Box 6130 LRIT Disclaimer Sirius is a brand name owned by Polaris Electronics
More informationINSTALLATION INSTRUCTIONS TALKBACK MODULE
273 Branchport Avenue Long Branch, N.J. 07740 (732) 222-6880 MODEL NUMBER: TBM-101 FCC REGULATIONS: INSTALLATION INSTRUCTIONS TALKBACK MODULE This equipment complies with Part 68 of the FCC Rules. On the
More informationNESS 5000 SERIES DIALLER
NESS 5000 SERIES DIALLER INSTALLATION MANUAL This manual is designed to provide the installation instructions on the NESS SECURITY PRODUCT'S 5000 SERIES Dialler. For complete details on the warranty or
More informationPreface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.
Preface Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock. The GSM Security Alarm ( The Alarm ) adopts the most advanced
More informationUser Manual (LS-GSM-006)
GSM Home/Business Alarm System User Manual (LS-GSM-006) Profile For a better understanding of this product, please read this user manual thoroughly before using it. - 1 - Catalogue: Function Introduction
More informationPiSector GSM Cellular Wireless Alarm System
PiSector GSM Cellular Wireless Alarm System User Manual ( GS08 ) Read manual fully before use. PiSector Inc., USA, www.pisector.com Welcome to PiSECTOR Thank you for choosing PiSECTOR. Everyone at PiSECTOR
More informationAuto Dialer. Manual E-921APQ E-921GPQ
Troubleshooting: Auto dialer will not arm/disarm Auto dialer will not dial out Unit doesn t respond to a call-back Difficulty in activating room monitor by telephone remote control Make sure that you have
More informationThank you for choosing Ideal Security s Home Security System with Telephone Dialer.
SK618 WIRELESS ALARM SYSTEM WITH AUTO DIALER OWNER'S MANUAL Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. If at any time during your installation you have any questions
More informationBurglar-alarm unit. User manual. Part. U3499A - 11/08-01 PC
Burglar-alarm unit User manual 5739 34 5739 35 Part. U3499A - 11/08-01 PC Contents 1. Introduction 5 The Burglar-alarm Unit 6 The keypad 7 Navigation keys 7 The display 7 Initial page 7 In case of an
More informationModel: M30. Owner s Operation Manual. For correct operation, please read this manual to familiarise yourself with the features.
Model: M30 Owner s Operation Manual For correct operation, please read this manual to familiarise yourself with the features. Includes wiring diagram We recommend professional installation of this security
More informationSOFTWARE VERSION 2.20 CONTROL PANEL RESET:
-961112-0002 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3
More informationMK9 series CarePhone. Installers Mauual
MK9 series CarePhone Installers Mauual 1 Please ensure that the last thing you do before leaving a User with an alarm is to make a test call through to the Monitoring Centre and speak to the Operator.
More informationMEDI-CALL UNIT INSTALLATION MANUAL. Medi-Call V2.0 - V2.7 Installation Manual
MEDI-CALL UNIT INSTALLATION MANUAL Medi-Call V2.0 - V2.7 Installation Manual Copyright SmartLink International Pty Ltd February 2006 475 Nepean Highway, Brighton VIC 3186 Australia Telephone: +61 3 9596
More informationAXI LED USER MANUAL (REV. 1.0)
Security & Home Automation System AXI LED USER MANUAL (REV. 1.0) CONTENTS PREFACE FEATURES LED KEYPAD OUTLOOK 1.0 LIGHT INDICATION 1 2 4 6 CHAPTER 1: ALARM SYSTEM CONTROL 1.0 USING LED KEYPAD 1.0.1 ARMING
More informationTo activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.
Table of Content 1.1General Description----------------------------------------------------------------------2 2.2System Setup-----------------------------------------------------------------------------3
More informationD6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.
Notice The material and instructions covered in this manual have been carefully checked for accuracy and are presumed to be reliable. However, Radionics, Inc. assumes no responsibility for inaccuracies
More informationINSTALLATION MANUAL PC56O. Version 1.OA
INSTALLATION MANUAL PC56O Version 1.OA TABLE OF CONTENTS INTRODUCTION 3 Features... 3 Specifications... 3 INSTALLATION 4 Mounting the Control Panel... 4 Mounting the Keypad... 4 Wiring... 5 Burglary Zone
More informationInfraTec Premium. Assembly and operating instruction. 20 min. Made in Germany. Druck Nr en/ :00 20 C
InfraTec Premium Assembly and operating instruction Made in Germany Druck Nr. 29344379 en/ -44.11 D 1 English Table of Contents Technical data...4 Scope of delivery...4 General information...5 General
More informationVAP304 PRO INSTALLATION & OPERATION MANUAL
VAP304 PRO INSTALLATION & OPERATION MANUAL Panic Fire Duress Program Bypass Report Chime Test Memory B A D C Program Chime Panic Duress Exit Fire Report Bypass Memory Test Reset Password Exit Reset Password
More informationQUICK USER MANUAL. Alarm Control Panel. The full user manual and other manuals are available on
Alarm Control Panel Firmware Version 1.09 QUICK USER MANUAL The full user manual and other manuals are available on www.satel.eu versa_ip_us_en 11/17 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND
More informationBURGLAR ALARM PANEL BS-468
BURGLAR ALARM PANEL BS-468 Contents 1. Description... 3 2. Instructions for the user... 4 2.1Basic operations... 4 Complete system.... 4 Split system.... 4 2.2 Armed system indication... 5 2.3 Advanced
More informationTECHNICAL. Voice Alarm Dialing or Store Caster Announcements from up to Eight Inputs. K-2000-DVA Multi-Input Voice Dialer/Announcer
TECHNICAL Practice TELECOM SOLUTIONS FOR THE 21ST CENTURY K-2000-DVA Multi-Input Voice Dialer/Announcer May 28, 2009 Voice Alarm Dialing or Store Caster Announcements from up to Eight Inputs Features Viking
More informationThank you for choosing Ideal Security s Home Security System with Telephone Dialer.
SK618 WIRELESS ALARM SYSTEM WITH AUTO DIALER OWNER'S MANUAL Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. If at any time during your installation you have any questions
More informationSOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)
-961112-0003 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3
More informationMG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide
MG6250 2-Partition 64-Zone Wireless Console with GPRS/GSM Version.6 Section Programming Guide Things You Need to Know About this Programming Guide The MG6250 All-in-one Wireless Console can be programmed
More informationOntech GSM 9040/50. Reference Manual English -1 -
Ontech GSM 9040/50 Reference Manual English -1 - Content Welcome... 5 This manual... 5 Text styles... 5 Support... 5 Disclaimer... 5 Overview... 6 Accessories... 6 External temperature sensor 9901... 7
More informationControl Panel. Operators Manual TO SUIT AS216 KEYPAD. AS216-OM-6.2. Advanced Digital Controls
Control Panel Operators Manual TO SUIT AS216 KEYPAD AS216-OM-6.2 Ultra-16 Control Panel AS216 OPERATORS MANUAL Copyright 2002 by NZ Ltd Auckland, New Zealand Document Part Number: This document is provided
More informationSingle Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3
Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions and Operation/Troubleshooting Manual 7000 Apple Tree Avenue Bergen, New York 14416 Phone:
More informationMOBILE CALL GSM Alarm System User s Manual
MOBILE CALL GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction (3) Alarm Host Diagram
More informationRef.1067/032 Ref.1067/042
DS1067-033A Mod. 1067 LBT8631 BUS CONTROL PANEL 8/32 INPUTS Ref.1067/032 Ref.1067/042 USER MANUAL TABLE OF CONTENTS 1 PREFACE... 5 2 COMMAND DEVICES... 6 2.1 1067/021 DISPLAY KEYPAD... 6 2.2 ELECTRONIC
More informationFreezeAlarm Dialer FA-700 Installation and Operations Manual
FreezeAlarm Dialer FA-700 Installation and Operations Manual Emerson Control Products Inc. 1724 Lake Drive West Chanhassen, MN 55317 Document No. 42420079B Table of Contents Cautions and warnings... 4
More informationVoice Dialer Temperature & Power Loss Monitor VD-5100-TM / VD-5101-TM
Innovative Technologies n Custom Electronic Design & Manufacturing General Description The VD-5100-TM (Fahrenheit) and VD-5101-TM (Celsius) Voice Dialer monitors temperature and power status. Upon an alarm
More informationContents. Glossary
Contents Glossary ------------------------------------------------------------------------------------------------------ 6 1. Introduction to the IDS 1632 -------------------------------------------------------------
More information1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point
Medium - Control - System Franke & Haqenest GmbH Borngasse 1a * 04600 Altenburg Tel: 03447-499 313-0 Fax: 03447-499 313-6 email: info@mcs-gaswarnanlagen.de MCS User Guide MCS GasController Microprocessor
More informationInstallation and Operating Instructions
Installation and Operating Instructions Models: HO-4-6S-CER-T HO-4-6NF-CER-T For your convenience, we recommend to attach the serial number label HERE. As part of Parmco Appliances commitment to improving
More informationAdvisor Advanced User Guide
Advisor Advanced User Guide P/N 1068996 (EN) REV G ISS 28AUG15 Copyright Trademarks and patents Manufacturer Version Certification 2015 UTC Fire & Security Americas Corporation, Inc. All rights reserved.
More informationINSTALLATION AND OPERATION INSTRUCTIONS
MODEL: RCT-MLT III INSTALLATION AND OPERATION INSTRUCTIONS INTRODUCTION IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT ATTEMPT TO INSTALL OR OPERATE This remote control system
More informationUSER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)
User Codes (1-6 digits) Access Levels Access Levels + Time Control User 1 (Master) 1 1 2 3 25 49 73 0 User 2 2 26 50 74 0 User 3 3 27 51 75 0 User 4 4 28 52 76 0 User 5 5 29 53 77 0 User 6 6 30 54 78 0
More informationINSTALLATION AND OPERATING MANUAL
INSTALLATION AND OPERATING MANUAL Refrigerated Cases with Air-Over Displays Refrigerated High Profile Grab-N-Go FOR PARTS & SERVICE Contact: Piper Products, Inc. Phone: (800) 544-3057 Ask for Service Department
More informationStatic Pressure Control
The (model SPC-2) is a fully programmable controller that provides extensive flexibility for your curtain or awning control needs. The SPC-2 automatically controls the pressure in a room by operating a
More informationFreeze Alarm. General Description VD-6300-MCS / VD-6301-MCS. Applications. Features. Specifications. Dimensions
Innovative Technologies in Custom Electronic Design & Manufacturing General Description The VD-6300-MCS Freeze Alarm monitors temperature, power status, security or an external contact, and offers remote
More informationD A R A - 4. Data Aire Relay Auto-Changeover
D A R A - 4 Data Aire Relay Auto-Changeover WARNING: If adding the DARA-4 panel to existing units that did not include a DARA-4 panel when originally purchased it will be necessary to add a relay or relays.
More informationLiqTec, V GRUNDFOS INSTRUCTIONS
GRUNDFOS INSTRUCTIONS LiqTec, 80-130 V Installation and operating instructions Notice d installation et d entretien Instrucciones de instalación y funcionamiento LIMITED WARRANTY Products manufactured
More informationPRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR
In the Master function, the remote control entries will be acknowledged as follows: acknowledged 3 x with the red LED In the Slave function, each detection is acknowledged 2 x with the green LED. NOTE:
More informationInstruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!
Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 74363 Güglingen Telefon +49 7135-102-0 Service +49 7135-102-211 Telefax +49 7135-102-147 info@afriso.de
More information1. Introduction. 2. Product overview
1. Introduction The AG400011 GSM Alarm panel is a control panel that is compatible with other H-net security devices from Everspring, such as wireless sensors, remote keyfobs, tags, and keypad. With this
More informationProfile. For a better understanding of this product, please read this user manual thoroughly before using it.
Intelligent GSM Auto-Dial Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction (3) Alarm
More informationUser s Manual. THE iq Drive SYSTEM USER S INFORMATION IMPORTANT. Variable Speed Ultra-High SEER Split System IMPORTANT NOTE
User s Manual Variable Speed Ultra-High SEER Split System These units have been designed and tested for capacity and effi ciency in accordance with ARI standards. These outdoor air conditioning units are
More informationHealth Care. NewVoice. San Francisco Paris Geneva Zurich Linz Mainz Shanghai Brisbane Hong Kong São Paulo Dubai
Health Care Emergency & Medical Services Nurse Call Heart Alarm Emergency Hotline Skill Based Mobilization Emergency Conference Bed Transportation MobiCall Health Care Security & Infrastructure MobiCall
More informationUser instructions EasyAlarm CONTROL
LEITRONIC AG Swiss Security Systems TELEMONITORING / TELECONTROLLING SYSTEM User instructions EasyAlarm CONTROL Interface-Modul Potential free relay switch: 10..230V AC or DC AC-switch: max. 2A / 230V
More informationProgramming the Vi+ using a Series Telephone. Tunstall Vi+
Tunstall Vi+ Programming the Vi+ using a SeriesTelephone Your Vi+ Page 2 Ver 1 4/24/2015 Programming a telecare sensor to the Vi+ Telecare sensors with plug and play functionality can be programmed to
More information87cm. Cooker hood. Stainless steel JLCEILHD87. User guide
87cm Cooker hood Stainless steel JLCEILHD87 User guide 2 Cooker hood user guide Contents Contents 3 Introduction 4 Safety is important 4 In the box 4 Safety information 5 Important safety information 5
More informationAll-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160
All-In-One Wireless Security System V3.2 Programming Guide Model # MG6130 / MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com
More informationAlarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual
WIC-16Z4P WIC-5Z2P Installation & Operation User Manual Page : 1/34 INDEX # Function Page 1 Abort Current Communication and Clear Reporting Queue (*59) 13 2 Abort Current Communications (*59) 10 3 Account
More informationDYGIZONE GJD910 Lighting Controller & Enunciator
DYGIZONE GJD910 Lighting Controller & Enunciator MASTER WIRING IDENTIFICATION Power up to the DygiZone and you will see: All the LED s (red,yellow,green and blue buttons) will flash All the LCD icons will
More informationHEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING
-961212-0004 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. ( 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2) Connect
More informationElite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand
6 Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd Operating Guide 1 Proudly Designed and Manufactured in New Zealand CONTENTS Page No. INTRODUCTION 3 About your Alarm 3 OPERATING YOUR
More informationAVCOM System Installation Instructions
AVCOM System Installation Instructions Index 1) AVCOM EN-1 System Drawings - AVCOM EN1 System.. Page 1 - AVCOM EN1 with 2COP.. Page 2 - AVCOM EN1 FF System.. Page 3 -AVCOM EN1 Evacuation System Page 4
More informationUser s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access
II User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access Part #2139703 Rev. G II Table of Contents Introduction...3 Elevator Overview...4 Description of Features...5-7
More information