Control Panels and Fire Detection Equipment
|
|
- Easter Bell
- 5 years ago
- Views:
Transcription
1 Control Panels and Fire Detection Equipment
2 Quaestor-SZU... Page 03 Quaestor-SZU Ancillary Board.... Page 04 Quaestor-MZE BS... Page 05 Quaestor-SZE BS... Page 06 Quaestor-SZE Ancillary Board... Page 07 Venator-DU Detectors... Page 08 Detectors... Page 09 Contacts... Page 10
3 Quaestor-SZU Extinguishant Control Panels QUAESTOR -SZU Extinguishant Control Panel Product Overview Designed and manufactured to the highest standards in a quality controlled environment and with UL approval the Quaestor-SZU releasing panel offers outstanding value and performance for all small to medium fixed firefighting installations. With 3 initiation circuits as standard, release can be configured to activate from any combination of detection zone inputs to allow (among other combinations) any 2 from 3 type activations such as would be required for detection in ceiling void, room and floor void applications. The extensive configuration options of the Quaestor-SZU allow functionality of the system to be extensively modified. The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until release for added user safety. SHW80001 The countdown timer is duplicated on up to seven remote status units to provide local indication of the system status. SHS80001 Programmable Functions Access Level 2 Test Zones 1 to 3 Disable Zones 1 to 3 Disable 1st Stage Alarms Disable Pre-activated 1st Stage Relay Disable Pre-activated 2nd Stage Relay Disable Extract Fan Output Disable Manual Release Input Disable Releasing Sub System Activate Extract Fan Output Activate Alarm Delays Access Level 3 Sounder Delay Coincidence Detection Disable Panel Features Zone Alarm Delays (Detectors) Zone Alarm Delay (Call stations) Configure Zone for I.S Barrier Use Zone Short Circuit Alarm Zone Non Latching Zone Inputs Delay Extinguishant Release Time Delay Extinguishant Release Duration Timer Extinguishant Reset Delay Timer With all of the electronics mounted on a single, easy, removable, steel plate Quaestor-SZU panels are both robust and easy to install. Features UL864 Three initiation circuits as a standard Any single zone or any combinations of zones can be configured to release Configurable first stage NAC delays Zero time delay upon manual release option Compatible with I.S. barriers Non-latching zone input option to receive signals from other systems such as aspirating equipment Configurable releasing delays up to 60 seconds in 5 second steps Configurable releasing delays up to 5 minutes in 5 second steps Countdown timer shows time remaining until release Support up to 7, 4 wire status indicators Built in Extract Fan control page 03 Safety Hi-Tech
4 Quaestor-SZU Extinguishant Control Panels Quaestor-SZU Ancillary Board The Quaestor-SZU Ancillary Board is compatible with all Quaestor control panels. The board provides volt free normally open contacts allowing control of sub-systems and plant remotely from the main panel over a two wire data bus. Ancillary boards require only a two core data cable from the main control panel and a two core power cable from the main panel. Up to 7 Ancillary boards can be connected to a control panel and each is allocated an address from 1 to 7 using a binary coded DIL switch. The total length of the data cable from the main panel to the last repeater must not exceed 4000 feet. A mixture of status units and Ancillary boards, up to a maximum of 7 of each type, can be connected to the serial data bus. The operation of this product is intended for indoor use only. The wiring diagram below illustrate connections for all SHA80001 models of the Quaestor-SZU Ancillary board Wiring Diagram 1-1 Quaestor-SZU Ancillary Board Connections: Connect (+) 24V DC to (+) 24V DC of the Quaestor-SZU Releasing Fire Control Panel. Connect Fire Zone Relays to detection zones of the Quaestor-SZU Releasing Fire Control Panel. Connect (+) IN to (+) OUT of the Quaestor-SZU Releasing Fire Control Panel. Connect (-) 24V DC to (-) 24V DC of the Quaestor-SZU Releasing Fire Control Panel. Connect these relay-terminals to releasing circuits of the Quaestor-SZU Releasing Fire Control Panel. Connect (-) IN to (-) OUT of the Quaestor-SZU Releasing Fire Control Panel V 24V Z1 Z2 Z3 MAN DISAB REL ACT HOLD EXTR MAN RS485 RS485 DC DC FIRE FIRE FIRE MODE REL OUT IN Connect ( + ) 24V DC to ( + ) 24V DC of the next Quaestor-SZU Status Unit or Quaestor-SZU Ancillary Board. Connect ( + ) OUT to ( + ) IN of the next Quaestor-SZU Status Unit or Quaestor-SZU Ancillary Board. Connect ( - ) 24V DC to ( - ) 24V DC of the next Quaestor-SZU Status Unit or Quaestor-SZU Ancillary Board. Connect ( - ) OUT to ( - ) IN of the next Quaestor-SZU Status Unit or Quaestor-SZU Ancillary Board. page 04 Safety Hi-Tech
5 Quaestor-MZE Extinguishant Control Panels QUAESTOR -MZE Multi-Area Extinguishant Control Panel Product Overview Quaestor-MZE control panels are multi-area extinguishant control panels complying with EN , EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface. Control Panels All extinguishant may have up to 7 serially connected Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Quaestor CP Ancillary boards (SHA00002) or Quaestor CP Sounder boards (SHA00003) to the RS485 serial bus. See data sheet DS39 and DS48. BS-EN KM SHA70001 SHA80002 Features Approved to EN , EN54-2 and EN54-4 2, 4 or 8 detection zones 1 to 4 extinguishant areas Dual Extinguishant outputs for each area (configurable as Main/Reserve) First and second stage sounder outputs for each area First and second stage volt free changeover contacts for each area Released volt free contact per area Programmable extinguishant delays Programmable output duration Extract fan control Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input Monitored remote Hold input Monitored remote Mode select (door interlock) input Monitored remote Released pressure switch input Monitored remote Low pressure switch input Monitored Abort input Serial connection for Si status units and ancillary boards, (SHA70001) SHA80003 page 05 Safety Hi-Tech
6 Quaestor-SZE Extinguishant Control Panels QUAESTOR -SZE Extinguishant Control Panel Product Overview Designed and manufactured to the highest standards in a quality controlled environment and with European EN approvals, the Quaestor-SZE extinguishant releasing panel offers outstanding value and performance for all small to medium fixed firefighting installations. With 3 detection zones as standard, extinguishant release can be configured to activate from any combination of detection zone inputs to allow (among other combinations) any 2 from 3 type activations as would be required for detection in ceiling void, room and floor void applications. BS-EN KM SHW70001 Programmable Functions Access Level 2 Test Zones 1 to 3 Disable Zones 1 to 3 Disable 1st Stage Alarms Disable Pre-activated 1st Stage Relay Disable Pre-activated 2nd Stage Relay Disable Extract Fan Output Disable Manual Release Input Disable Extinguishant Sub System Activate Extract Fan Output Activate Alarm Delays Access Level 3 Sounder Delay Coincidence Detection Disable Panel Features Zone Alarm Delays (Detectors) Zone Alarm Delay (Call stations) Configure Zone for I.S Barrier Use Zone Short Circuit Alarm Zone Non Latching Zone Inputs Delay Extinguishant Release Time Delay Extinguishant Release Duration Timer Extinguishant Reset Delay Timer SHS70007 The extensive configurations options of the Quaestor- SZE allow the functionality of the system to be extensively modified while still complying with the requirements of the controlling standard for the equipment (EN , EN54-2 and EN54-4). The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until release for added user safety. The countdown timer is duplicated on up to seven remote status units to provide local indication of the system status. With all of the electronics mounted on a single, easy, removable, steel plate Quaestor-SZE panels are both robust and easy to install. Features Approved to EN , EN54-2 and EN54-4 Three detection zones as standard Any single zone or any combinations of zones can be configured to release Configurable first stage sounders delays Zero time delay upon manual release option Compatible with I.S. barriers Non-latching zone input option to receive signals form other systems such as aspirating equipment Configurable releasing delays up to 60 seconds in 5 second steps Configurable releasing delays up to 5 minutes in 5 second steps Countdown timer shows time remaining until release Support up to 7, 4 wire status indicators Built in Extract Fan control 06 Safety Hi-Tech
7 Quaestor-SZE Extinguishant Control Panels Quaestor-SZE Ancillary board There is sometimes a requirement to extend signals from the extinguishing system for additional plant control or other signalling applications such as interfaces to BMS systems or house fire alarm systems. The Quaestor-SZE is equipped with a selection of volt free contacts which are often adequate for this purpose. For applications that require more outputs from the system, the Quaestor- SZE ancillary board is available. Up to 7 ancillary boards may be connected to the status unit serial bus to provide distributed control and signalling at multiple locations if required. Each output has an LED indicator which shows which outputs are operated. The Quaestor-SZE ancillary board contains volt free changeover contacts for signalling of the following: SHA70001 Quaestor Ancillary PCB Zone 1 fire Zone 2 fire Zone 3 fire Manual only mode Disablement active Released Activated Manual release operated Extract fan operated Hold activated One ancillary board can be mounted within a Quaestor-SZE control panel on push-in standoffs behind the main equipment chassis. Alternatively, Quaestor-SZE ancillary boards are available in enclosures that match the styling of the control panel V DC 24V DC PF Z1 FIRE Z2 FIRE Z3 FIRE MAN MODE DISAB REL ACT HOLD EXTR MAN REL + - RS485 OUT + - RS485 IN Example System Schematic Detection Zone 3 Detection Zone 2 1st Stage Sounders 2nd Stage Sounders Hold Manual Release Door Interlock MAN Z1 Z2 Z3 MAN DISAB REL ACT REL EXTR HOLD Low Pressure Switch Released Pressure Switch Activate Extinguisher OK PROCESSOR RESET FUSE FAIL ADDRESS Detection Zone 1 System Status and Control 4 Core Addressable House Fire Alarm Ancillary Board BMS Interface EN Approved Control Unit System Status and Control System Status and Control Ancillary Board 4 Core 07 Safety Hi-Tech
8 Venator-DU Fire Detection Equipment VENATOR -DU Fire Detectors Product Overview Venator-DU incorporates well-proven technologies, together with advances in materials and electronics technology, including an IC based. Having a wide operating voltage of 9-33V, the Ventator-DU detectors can be integrated into security systems, when used with a relay base. The Venator-DU wide voltage range consists of ionisation, integrating ionisation and optical smoke detectors, 2 grades of heat detector and a range of bases. All detectors are equipped with flashing LED. All detectors and bases are listed by UL and ULC. Venator-DU Ionisation Smoke Detector Venator-DU Optical Smoke Detector Venator-DU Heat Detector Venator-DU Normal Base Venator-DU Base with Relay page 08 Safety Hi-Tech
9 Fire Detection Equipment VENATOR -DE Fire Detectors Product Overview incorporates well-proven technologies, together with advances in materials and electronics technology, including an IC based. Having a wide operating voltage of 9-33V, the Ventator-DU detectors can be integrated into security systems, when used with a relay base. The wide voltage range consists of ionisation, integrating ionisation and optical smoke detectors, 2 grades of heat detector and a range of bases. All detectors are equipped with flashing LED. All detectors and bases and call points are approved EN4-7:2000 and EN4-5: Ionisation Smoke Detector Optical Smoke Detector Heat Detector Normal Base Base with Relay Manual Call Point page 09 Safety Hi-Tech
10 CertifiedSafetyPassion Our mission is to be successful by embracing the philosophies of high quality, advanced techniques, and customer service with a range of products and services always focused on safety and environmental sustainability. The performance of all our products, system components and design software programs are certified by internationally recognized independent laboratories, ensuring that the complete system is reliable and safe. SAFETY HI-TECH is a registered trademark of Safety Hi-Tech srl. UL Listing Mark is a registered trademark of Underwriters Laboratories Inc. Quaestor, Venator and Certified Safety Passion are trademarks of Safety Hi-Tech srl. Safety Hi-Tech Srl Via degli Olmetti, 5B Formello Italy, European Union Tel: Fax: Website: customer.service@safetyhitech.com
CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML
CertifiedSafetyPassion SAFETY HI - TECH. Founded in 1990, Safety Hi-Tech is a customer-focused provider of innovative fire suppression solutions, focusing on Clean Agent Extinguishing Systems. Safety Hi-Tech
More informationAn introduction to... Sigma
An introduction to... Sigma XT+ Sigma XT+ Overview The Sigma XT+ 21000 series are the latest additions to the Sigma family of control equipment from Kentec Electronics Limited. The Sigma XT+ range combines
More informationThis wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control
File: S8485 Wiring Diagram This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control Panel. The operation of this product is intended for indoor
More informationConventional Fire Control Panel with Extinguishant Control Unit. Operation and Maintenance Manual SIGMA-2-M3-ECU SIGMA-4-M3-ECU SIGMA-8-M3-ECU
SIGMA-CP Issue 12 October 2011 AFP-2516 Conventional Fire Control Panel with Extinguishant Control Unit Operation and Maintenance Manual SIGMA-2-M3-ECU SIGMA-4-M3-ECU SIGMA-8-M3-ECU SIGMA-XT Issue 1 October
More informationApplication, Installation, Operation & Maintenance Manual
APPROVED BY:JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL Application, Installation, Operation & Maintenance Manual PAGE 1 of 43 CONTENTS 1. INTRODUCTION... 3 2. GENERAL DESCRIPTION...
More informationInstallation, Operating and Maintenance Manual
STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS
More informationPNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel
PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum
More informationSALES SUPPORT DOCUMENT
SALES SUPPORT DOCUMENT ML-322 MAXLOGIC CONVENTIONAL FIRE EXTINGUISHING CONTROL PANEL ML-322 series operates on cross-zone principle, has 4 detection zones and one extinguishing release output which is
More informationSigma XT+ Extinguishant Control Panel. Operation and Maintenance Manual
Sigma XT+ Extinguishant Control Panel Operation and Maintenance Manual Man-1112 Issue 9 March 2010 Index Introduction... 5 2. Safety and mounting... 6 2.1 Safety... 6 2.2 Mounting... 7 3. Technical specification...
More informationSystem 800 Addressable Fire Detection & Alarm System
SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools
More informationUSER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4
PREMIER EX8 EXTINGUISHING PANEL USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN 12094 PART 1 & EN54 PARTS 2 & 4 USER MANUAL Approved Document No: GLT.MAN-132 INDEX Extinguishing
More informationThe ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features
990-052, Issue 6 20 March 2006 ID50 Series Single Loop Intelligent Fire Alarm Panels Section: Intelligent Fire Alarm Panels GENERAL The NOTIFIER ID50 series single loop intelligent fire alarm panels, has
More informationPERTRONIC INDUSTRIES LTD F4-RMAX Installation Note
Product Overview: The Pertronic F4 Remote LED Mimic / Aux Relay Module F4-RMAX is an optional extra for the Pertronic F4 conventional 4-zone fire alarm panel. This board enables the fire alarm panel to
More informationFIREBETA EXTINGUISHING CONTROL PANEL (ECP)
F I R E D E T E C T I O N A N D C O N T R O L FIREBETA EXTINGUISHING CONTROL PANEL (ECP) Three versions: 2 areas of detection and 1 area extinguishing 4 areas of detection and 1 area extinguishing 4 areas
More informationOperation and Maintenance Manual
(FKER Series) Repeater Panel (FKER, FKER, FKER8) Operation and Maintenance Manual Man-9EL Issue June Index Section Page. Introduction.... Safety and mounting.... Technical specification.... Control panel
More informationSigma XT. Extinguishant Control Panel. User Manual Man-1091 Issue 03 October 2009 (K11031M2, K11031F2)
Sigma XT Extinguishant Control Panel (K11031M2, K11031F2) User Manual Man-1091 Issue 03 October 2009 Fire alarm condition General fire indicator lights and zonal fire indicators flash. Buzzer sounds urgently.
More informationMINERVA MX. 800 Series Ancillary Equipment
An extensive range of ancillary modules has been specifically designed for use with the MX range of Fire Controllers. The 800 range of ancillary modules provide the MX Fire Controller with a wide degree
More informationSyncro AS. Analogue Addressable Fire Control Panel. User Manual
Syncro AS Analogue Addressable Fire Control Panel User Manual Man-1100 Issue 02 Nov. 2008 Index Section Page 1. Introduction...3 2. Safety...3 3. Panel Controls...4 3.1 Access Level 1...4 3.2 Access Level
More informationLaserFOCUS VLF-250 Engineering Specification
Vision Fire & Security LaserFOCUS VLF-250 Engineering Specification May 2004 Part Number 20296 LaserFOCUS VESDA 2 VESDA LaserFOCUS Contents Scope...4 Description...4 General...4 Approvals...4 Codes, Standards
More informationAddressable Fire Alarm Control Panel
PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT
More informationConventional Releasing Control Panel
s Data Sheet Fire Safety Products Conventional Releasing Control Panel Pre-Action Deluge Agent-Releasing Fire System Model TXR-320 Remote configurable Up to two (2) hazard areas Operable with the following:
More informationReliably Advanced Extinguishing Control
Reliably Advanced Extinguishing Control The Best Choice for Asset Protection What suppression and extinguishant control panel would you choose to protect the literary collection of an entire nation? 47
More informationIntelligent Security & Fire Ltd
OPERATIONAL NOTES FOR CONCEPT FIRE PANEL. NOTE ON NEW FIRE PANELS, POSITION 1 ON THE SIX WAY INTERNAL OPTION SWITCH IS TURNED ON, DISABLING THE ZONAL SOUNDERS. TO ENABLE ZONAL SOUNDERS TURN OFF. Operation
More informationZIOU/230 - MAINS IO INSTRUCTION MANUAL
Description ZIOU/230 - MAINS IO INSTRUCTION MANUAL The Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third party equipment with the Fire Alarm Control panel
More informationGAS FLOODING SYSTEM FOR CIFF AT BASEMENT
CONSTRUCTION OF BUILDINGS FOR LABORATORIES AND ASSOCIATED FACILITIES INSTEM BANGALORE SCHEDULE OF QUANTITIES FOR (EQUIPMENT ROOM 3 & 4) Sl.No. Description Unit Quantity Rate (in INR) in figure HFC-227ea
More informationReliably Advanced Extinguishing Control
Reliably Advanced Extinguishing Control 14 years. 60 countries. Still Advanced. We re the same people, with the same commitment to excellence and customer satisfaction and now we have a brand that reflects
More informationEnd To End Optical Beam Smoke Detector. Additional Information
End To End Optical Beam Smoke Detector Additional Information EN 1. Multiple Zone Wiring When using more than one System Controller on a single zone of a conventional Fire Control Panel (FCP), it is important
More informationThe supplier and installer of the system should be approved by the local civil defence authority.
ANALOGUE ADDRESSABLE FIRE ALARM SYSTEM 1. Scope of Work The contractor shall supply, install, test and commission a modern Analogue Addressable Fire Detection and Alarm System of an approved manufacturer
More informationGas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016
Gas Safety Products Installation, operating and maintenance 05/10/2016 American Gas Safety LLC 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel Mounting.... 3 2.2 Mains Supply...
More informationDifferent types of Fire Alarm System
Different types of Fire Alarm System Conventional Fire System Generally comes with Zones. Each zone can have max 20 detectors. Addressable Fire Alarm System This comes in loops. Different manufacturer
More informationZSC100 Gas Detection and Alarm System Controller
ZSC100 Gas Detection and Alarm System Controller User Guide 1- Introduction... 3 1.1- General description... 3 1.2- Cautions and warnings... 3 2- Control panel... 4 2.1 Control panel overview... 4 2.2
More informationSigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009
Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual Man-1048 Issue 05 October 2009 CONTENTS Contents... Page Safety & Installation...2 Installation - continued...3
More informationUser Operation Manual
APPROVED BY: JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL User Operation Manual PAGE 1 of 6 1 CONTENTS 1. FIRE - GENERAL... 3 2. FIRE - ZONES 1 OR 2 - AUTOMATIC MODE... 3 3. FIRE - ZONES
More informationSOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL
S S S S S S LISTED L * PATENT PENDING S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT U 99Y9 RESET RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE
More informationIntelligent addressable fire alarm control panel
Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity
More information5000 INSTALLATION GUIDE
5000 INSTALLATION GUIDE Table of Contents Section Page No 1. INTRODUCTION... 3 2. WARNINGS AND CAUTIONS... 3 3. UNPACKING... 3 4. INSTALLATION... 4 5. CONTROL PANEL - REMOVING ITEMS BEFORE MOUNTING...
More informationOPERATION AND INSTALLATION MANUAL
EX+Plus 2 ZONE, 1AREA EXTINGUISHANT CONTROL PANEL OPERATION AND INSTALLATION MANUAL INTRODUCTION The Premier EX Plus is a 2 zone, single area panel for controlling the release of extinguishing gases in
More informationRELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:
RELEASE DEVICES MADE IN THE U.S.A. RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: The "WPS" World Power Series, Time Delay Release
More informationPRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit
PRODUCT INSTRUCTIONS Fire Door Control Panel (FDCP) Floats Rd, Wythenshawe, Manchester. M23 9WB T: 44 (0)161 945 4561 F: 44 (0)161 945 4566 Stock Code Description Doc No: PI115 00133 00134 Ellard Fire
More informationUPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY
Important UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT
More informationDCS-100. intelligent damper control & monitoring system
DCS-100 intelligent damper control & monitoring system 02 //DCS-100 Introduction The Disys Technologies DCS-100 is a revolutionary new control system designed specifically for the fire/smoke damper controls
More informationFirefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL
Firefly II Multi Voltage RELEASE DEVICES Firefly II & IIB-MV INSTALLATION MANUAL GENERAL DESCRIPTION: S/N The The Cookson Company Firefly II-MV time delay release devices are designed for use on rolling
More informationFTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS
QUICK USER GUIDE FOR, 2 & 4 ZONE PANELS INDICATORS COLOUR INDICATION MON FAULT Yellow On when a fault condition has occurred, or if no other fault Led is on, this indicates 24v auxiliary fuse failure.
More informationMultiple Input and Output Modules
Kingfisher Company, inc. Multiple Input and Output Modules Features: Removable 12 to 18 AWG plug-in terminal blocks Individual LED indicators Unused addresses may be disabled Rotary address switches Class
More informationTX24-10A. Intelligent PSU Installation and Operation Manual. TANDA UK Technology Copyright 2016, All right reserved.
TX24-10A Intelligent PSU Installation and Operation Manual Technology Copyright 2016, All right reserved. Product Safety To prevent severe injury and loss of life or property, read the instruction carefully
More informationWhy Hart XL Aspirating Smoke Detection?
HART XL Why Hart XL Aspirating Smoke Detection? Earliest detection to enable business continuity Extra time is required for safe evacuation Unnecessary suppression release must be avoided Smoke is difficult
More informationDATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D
DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike s CyberCat 254 (P/N 10-066) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.
More informationFire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology
Fire-Cryer Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX Shaping Alarm Technology Fire-Cryer Plus The Fire-Cryer range of voice sounders was first introduced to the market by Vimpex in 1999.
More informationD7024 Fire Alarm Control Panel
D7024 Fire Alarm Control Panel The D7024 offers accurate, consistent performance with a feature set that elevates this panel to the top of its class. Fire systems you can rely on. D7024 24V Addressable
More informationData Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906
s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones
More informationE N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.
E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0E FL0E FL0E mm mm 0 mm DESCRIPTION The LT FL0 Series is part of the Fire Alarm Aspiration
More informationConventional Fire Control Panel
(FKEW Series) Conventional Fire Control Panel (FKEW2, FKEW4, FKEW8) Man-1138EL Issue 01 February 2014 Contents 1. Introduction... 4 2. Safety... 4 4. Technical specification... 5 5. Control panel fascia...
More informationWho we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide.
Who we are? - Nº 1 Spanish fire alarm systems manufacturer. - 25 years experience in the fire detection field. - 40 countries worldwide. Own engineering, design and factories. Total control of production
More informationConventional Smoke Detectors KFAPO
Kingfisher Company, inc. Conventional Smoke Detectors KFAPO Features: Wide operating voltage, 9-33 VDC Advanced electronic technology Flashing LED Magnetic test switch Proven detection performance Designed
More informationPREMIER EX8 INSTALLATION MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4 INSTALLATION MANUAL
PREMIER EX8 INSTALLATION MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN 12094 PART 1 & EN54 PARTS 2 & 4 INSTALLATION MANUAL Approved Document No: GLT.MAN-124 INDEX Extinguishing
More informationZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL
ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options
More informationAlgo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)
Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS) INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0)
More informationSmoke Vent Control Panel PCB4 V4 Installation Manual
Smoke Vent Control Panel PCB4 V4 Installation Manual 10A PCB4 Control Panel Do Not Remove From PCB4 Control Panel www.besafedirect.com Page 1 Contents Page 3) Important Regulations, Safety, Maintenance,
More informationGas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date:
Gas Safety Products Merlin 1500S Gas Interlock System Installation, operating and maintenance Rev: 03 Date: 08-01-18 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel Mounting....
More informationQuick Selection Guide Fire Systems LSN Periphery
Local SecurityNetwork Easy wiring Auto configuration capability (self-learning mode) Central programming of all device configurations from the panel Flexible network structure (Loop, stub, T-tap & mixed
More informationInstruction manual. W440 AIS Sart Sniffer
Instruction manual W440 AIS Sart Sniffer Ed. 1.2.0 () 9/2012 Doc: W440_1_2_0_ 1 2 3 Picture 1: Frontal view 4 3 Picture 2: Schematic diagram 4 Warning The crossed rubbish skip symbol indicates that the
More informationConventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014
Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual Man-1078EL Issue 01 February 2014 B Index Page 1. Introduction... 3 1B2. Safety and mounting... 3 2B3. Technical specification...
More informationPrecept Marine Control Panel Application Guide
Precept Marine Control Panel Application Guide Contents Page 1.0 Cabinet Specifications 2 2.0 Panel Hardware Specifications 5 3.0 Panel Configuration 8 4.0 Technical Specifications 8 5.0 Battery Sizes
More informationConventional & Twin-wire Fire System
Conventional & Twin-wire Fire System Advanced Customer Service At Advanced we re not just famous for our fire systems. Our Advanced360 customer support, service and technical training are widely acknowledged
More information2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.
ISSUES ISSUE DATE RELEASED DETAILS OF CHANGE AUTHOR 4 Rev 2 September 2004 Changes for 4000 series. DB 4 Rev 3 April 2005 Screen shots updated and other minor changes K.Z. 4 Rev 4 September 2006 4 Rev
More information2018 Johnson Controls. Tyco Fire & Security GmbH, Victor von Bruns-Strasse 21, 8212 Neuhausen am Rheinfall, Switzerland DUO-CEL
OM_FC_DUO-CEL_APP 2018 Johnson Controls. Tyco Fire & Security GmbH, Victor von Bruns-Strasse 21, 8212 Neuhausen am Rheinfall, Switzerland DUO-CEL FIRE DETECTION/ALARM PANEL Application Guide PAGE 1 of
More informationORION Mini-Rep INSTALLATION MANUAL
ORION Mini-Rep INSTALLATION MANUAL Orion Mini-Rep - INSTALLATION MANUAL - REVISION 1.0-04/007 The Orion Mini-Rep will provide remote control and system display status from multiple locations to an Orion
More informationRELEASE DEVICE CONTROLS
RELEASE DEVICE CONTROLS RELEASE DEVICE MODEL C+ INSTALLATION MANUAL UL LISTED CANADIAN LISTED CSFM: 7300-48:00 GENERAL DESCRIPTION: MADE IN THE U.S.A. S/N: The LM0-C+ Release Device/Control Panel is a
More informationIntelligent Security & Fire Ltd
full installation, commissioning and operating manuals can be downloaded from www.haes-systems.co.uk combined addressable / conventional fire alarm control panel User Guide Approved Document No. MFBU-04
More informationDiscovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide
Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel Application Guide Contents Page 1.0 Introduction and Typical System Illustration 2 2.0 Cabinet Specifications 4 3.0 Hardware
More informationIndustries. As a premier global manufacturing company, we believe that great brands are
JSB Fire Systems ONE COOPER Every day, thousands of people all over the world use products made by Cooper Industries. As a premier global manufacturing company, we believe that great brands are built on
More informationEX8. Instruction Manual: COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 AND EN54 PARTS 2 & 4
EX8 COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN 12094 PART 1 AND EN54 PARTS 2 & 4 Instruction Manual: Approved Document No: GLT.MAN-124 PAGE 2 INDEX INDEX... 3 Introduction... 4 Indications
More informationSpecification/ Data Sheet
Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)
More informationBoiler Room Control THE MERLIN RANGE GAS DETECTION EQUIPMENT ENGINEERED TO DELIVER EXCEPTIONAL LEVELS OF SAFETY
Boiler Room Control THE MERLIN RANGE GAS DETECTION EQUIPMENT ENGINEERED TO DELIVER EXCEPTIONAL LEVELS OF SAFETY 2 THE MERLIN RANGE AMERICAN GAS SAFETY Gas detection and controls for boiler house applications
More informationDS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel
DS3MX-E-I EN Installation Guide 3 Mini Control Panel DS3MX-E-I Installation Guide 1.0 General Information EN 2 1.0 General Information The DS3MX is a three zone mini control panel, which can be installed
More informationSita200plus. 200detectors. Single loop analogue addressable System
Single loop analogue addressable System Fast short circuit isolator in every device 15 combinations of smoke & heat detection modes Loop length up to 2km long with spurs INTELLIGENT FIRE TECHNOLOGY A D
More informationGas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:
Gas Safety Products Merlin 1000S+i Gas & Electric Utility Controller Installation, operating and maintenance Rev: 03 Date: 14-08-18 1 Table of contents 1 General information... 3 2 Installation... 3 2.1
More informationDoc. No Part No Rev. U * T*
Doc. No. 430545 Part No. 579-357 Rev. U *0579357T* Blank Page- Back of Front Cover Copyrights and Trademarks 2005-2018 Johnson Controls. All rights reserved. Specifications and other information shown
More information1) This manual covers 4400, 5400 and 6400 fire alarm systems. The differences are described in the appropriate sections.
ISSUES ISSUE DATE DETAILS OF CHANGE CHANGED BY 1 16/02/00 ORIGINAL ISSUE - 2 16/01/01 TABLES 2 & 3 UPDATED, ADDED TABLE 4 PWD 3 12/09/01 ADDITIONAL INFORMATION PWD 4 29/11/02 TABLES 2, 3 & 4 UPDATED &
More informationConsultant Specification AGILE Wireless Fire Detection System
Contents Scope of Work... 2 The EN54 Part 2 & 4 Fire System... 2 Standards... 2 Wireless Intelligent Photoelectric Smoke Detector Specification... 4 Wireless Intelligent Thermal Heat Detector Specification...
More informationPAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00
PAT E N T System 88 COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00 Pg 1 of 12 CONTENTS 1. GENERAL 1.1 Introduction 2 1.2 System Description
More informationNZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL
NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL Document No...G108WO1.DOC Serial No... Issue Date...17 th SEPTEMBER 1999 Software Version...1.4 APPROVED TO: NZS 4512:1997 AS/NZS 3548:1992 Fire Alarm
More informationCellarSafe. Carbon Dioxide and Oxygen Safety Monitor
CellarSafe Carbon Dioxide and Oxygen Safety Monitor Installation and operating instructions for the CellarSafe Monitor and the CellarSafe Calibration Unit M07234 May 2008 Issue 6 Warning Please take care
More informationFSTP4-2-wire 4 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS4 Issue 01 April 2012
FSTP4-2-wire 4 Zone Conventional Fire Control Panel Operation and Maintenance Manual Man-1078FS4 Issue 01 April 2012 Index Page 1. Introduction... 3 2. Safety and mounting... 3 3. Technical specification...
More informationDoc. No.: OMPII.DOC Rev. 2 Written By: Raj Patel Checked By: AJC Approved By: JBJ Date: 03/05/05
Doc. No.: OMPII.DOC Rev. 2 Written By: Raj Patel Checked By: AJC Approved By: JBJ Date: 03/05/05 PRESCIENT II GAS EXTINGUISHANT CONTROL PANEL INSTALLATION, OPERATION & MAINTENANCE MANUAL Page 1 of 27 CONTENTS
More informationSurveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above
Surveyor Excel Fire Alarm Control Equipment Network version Programming Manual VERSION 14.0 and Above MASTER MANUAL Drawing S1606. PCB Layout guide for XLK range of control panels FCPXLK-2/4/6/8 & FCPXLK2/4/6/8TW
More informationActionpac 60/120 (LNS Standard)
July 2006 Actionpac 60/120 (LNS Standard) Actionpac 60/120 (LNS Standard) Cost Competitive Intelligent Damper Control and Monitoring System Range and Features Panel system, utilising solid state technology.
More informationOn the job around the clock 24/7: Fire detection systems
On the job around the clock 24/7: Fire detection systems Version 02.2010 Version: 02.2010 Product catalogue Fire detection systems This product catalogue is intended for sales purposes only. For planning,
More informationProduct Catalogue 2017 Product Catalogue 1
Product Catalogue 2017 1 2 A Complete Solution Portfolio FirePro deliver a broad range of fire suppression systems and solutions for a multitude of applications in all industries. FirePro s state of the
More informationSYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System
SYSTEM MANUAL FT1-SB Single Zone Fire Alarm System DOCUMENT HISTORY Issue Date Description Written By Checked By Draft 0 2/9/2008 Original Document. A. Shenouda C. Orr Issue 1 4/11/2011 Update drawing
More informationNatural Ventilation Controller with 24vDC drive NVC-1204
Natural Ventilation Controller with 24vDC drive NVC-1204 BACnet Enabled C-036 08/11 FEATURES > 24V DC supply > Native BACnet communications > Master/Slave grouping (shared information) > 3 x 0-10V outputs
More informationMODEL B2 INSTALLATION MANUAL
RELEASE DEVICES GENERAL DESCRIPTION MODEL B2 INSTALLATION MANUAL S/N: The B2 Series Time Delay Release Devices are UL Listed, Canadian Listed, and CSFM Listed for use on rolling doors, single-slide and
More informationICS Regent. Fire Detector Input Modules PD-6032 (T3419)
ICS Regent Fire Detector Input Modules (T3419) Issue 1, March, 06 Fire detector input modules provide interfaces for 16 fire detector inputs such as smoke detectors, flame detectors, temperature detectors,
More informationFor Complete Fire and Gas Solutions
Industrial Fire For Complete Fire and Gas Solutions 2 The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable
More informationInstallation & Operation
Integrated Area Monitor IAM Integrated Area Monitor Control Panel IAM-C Installation & Operation Content Page 1- IAM Sensor -Installation Instructions 2 2- IAM Sensor -Location Instructions 2 3- IAM Sensor
More informationTechnical Data Sheet
Mx-1000 Series Technical Data Sheet Application Guide for Mx-1002, Mx-1004, Mx-1008, Mx-1016 & Mx-1032 Conventional Fire Alarm Control Panels And Mx-1108, Mx-1116 & Mx-1132 Repeater Panels Document Number:
More informationFire Product Catalog
Additional Expansion Modules Fire Product Catalog CLEVER FIRE SOLUTIONS MA 1000 / Analog Addressable Fire Alarm Panel 1 Military Industry Public Buildings Industrial & Commercial Company Profile We are
More information100 Series Gas Ventilation Interlock System
I am the installation instructions for a gas safety system, please read me before you have a go. The product I support is virtually indestructible but I have no doubt someone will try!! Intelligas takes
More informationFIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL
FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL MADE IN THE U.S.A. U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION SERIAL NUMBER The Cookson Company FIREFLY II PLUS Time Delay Release
More informationJUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL
Fire Alarm Control Panel & MANUAL CONTENTS SECTION -. Description of the fire control panel fascia.... Alarm.... Reset the system.... Sound and silence the alarms.... Read the Fire, Fault, Test and Disabled
More information