1 ATFLASH SENSOR USER GUIDE ATFLASH
2
3 INDEX A. INSTALLATION INSTRUCTIONS B. SENSOR: FIXING AND CONNECTIONS C. TURN ON/OF C.. TURN ON C.. TURN OFF 4 5 D. CONSOLE: FIXING AND CONNECTIONS E. LCD SCREEN INFORMATION F. DRY CONTACT RELAYS INFORMATION G. TECHNICAL SPECIFICATIONS 9 0
4 LIGHTNING RISK 0km 30km 5km ATFLASH A. INSTALLATION INSTRUCTIONS. For the installation of ATFLASH, 3 parts will be considered: : Always placed outdoors and above the roof. Provided with a multicore female connector. Cable: 5m cable Provided with a multicore male connector at one end (for connecting with the ) Console: Always placed indoors COMPONENTS: Mast ½, m long 4 4 Screws M8x0mm Anchorage pieces 5m connection cable console Power supply cable with schuko ATFLASH SENSOR
5 B. SENSOR: FIXING AND CONNECTIONS. Fix the anchorages to the wall. Pass the connecting cable through the mast and connect it to the sensor (see note). Fix the sensor to the mast with the provided 4 screws (M8). Place the mast with the sensor in the anchorage. The part of the cable running outdoors should be placed inside a guard tube. If this part is longer than meter then that tube should be fixed to the wall. The Console is a desktop device so no installation or special subjection is needed. The system is supplied with 5m connecting cable. Once the cable enters the building and reaches the place to be installed then it can be cut to the proper length (it has no connector). IMPORTANT CABLE CONNECTOR SENSOR CONNECTOR Fasten the cables in the connector. It is very important to follow carefully the color code: Grey Brown White N.C. Yellow Pink/Shield Connect to the power supply. 5 Note: The connecting cable is provided with a ferrite in one of its ends. It must be inside the mast. Do not handle.
6 C. TURN ON/OFF. C.. TURN ON. Plug the power cable in the appropriate receptacle in the back of the console.. Plug the schuko into the power supply. 3. Use the ON/OFF switch to turn on the equipment. C.. TURN OFF. Use the ON/OFF switch to turn off the equipment.. If it is necessary to remove power cable, unplug the schuko to the power supply first. IMPORTANT NOTE: Provide the equipment a ground connection This equipment is connected to ground through the grounding line of the power supply. To avoid electrical shock connect always this conductor to a grounded socket
7 D. CONSOLE: FIXING AND CONNECTIONS. ATFLASH SENSOR LIGHTNING RISK LCD Screen Alarm indicator Led: Storm is located between 0-30Km Alarm indicator Led: Storm is located between 30-5km Alarm indicator Led: Storm is located less than 5Km 0km 30km 5km Power indicator Led. No communication indicator Led. Switch ON/OFF and Power Schuko Cable connector for the sensor 7 AC INPUT 0 ~ 50V-0.3A 50-0HZ DRY CONTACT RELAYS Dry contact relays
8 E. LCD SCREEN INFORMATION. The LCD gives the information about the sensor state and the storm state with two lines of characters as follows: E.. SENSOR STATE E.. STORM STATE No communication between the sensor and the console. The sensor is sending wrong data NO COMMUNICATION ********************* DATA ERROR st Alarm Level nd Alarm Level STORM<0KM STORM<30KM 3 rd Alarm Level STORM<5KM 8 IMPORTANT NOTE: During the alarm state, the screen s first line changes in accordance to the proximity of the storm.
9 F.DRY CONTACT RELAYS INFORMATION. The Console is equipped with four free-contact outputs. Those outputs are four relays with two contacts: one normally open and the other normally closed. The connections are as follows: From left to right the configuration is:. No CONNECTION RELAY. 3rd ALARM LEVEL RELAY 3. nd ALARM LEVEL RELAY 4. st ALARM LEVEL RELAY 3 3 Normally open Common Normally closed 9
10 G. ATFLASH SENSOR TECHNICAL SPECIFICATIONS. OPERATING SPECIFICATIONS SENSOR MECHANICAL SPECIFICATIONS Detection Range 3 alarm levels Weight 347,5gr 0Km around the sensor Alarm sound Dimensions Ø70 x 95 mm Alarm levels 80 db Cable 5m SENSOR ELECTRICAL SPECIFICATIONS DC Voltage Protections +/- Vdc The sensor is protected against overcurrents and surges. Maximum separation distance Framework material IP Code Fixing 00m (optional cable) Polypropylene IP54 Fixed to ½ tube CONSOLE ELECTRICAL SPECIFICATIONS Power supply Frequency Power Relays outputs Protections 0-50Vac 50-0Hz 5 W 4 outputs (3 storm alarms and another one for no communication) Protected against overcurrents and surges. CONSOLE MECHANICAL SPECIFICATIONS Weight,3 Kg Dimensions 7 x 03 x 8 mm Material Galvanized steel MOUNTING SPECIFICATIONS Mast (depends on installation) ½ m galvanized steel mast included. 0 ENVIRONMENTAL SPECIFICATIONS working temperature -40 to 85ºC Console working temperature -0 to 85ºC Anchoring (depends on installation) Corrugated tube U-shaped anchorage consisting of galvanized steel, 30cm long support with screws for wall fixing (all included). Protection tube for communication cable included.
11 HEADQUARTERS PARQUE TECNOLÓGICO DE VALENCIA, C/ NICOLÁS COPÉRNICO, PATERNA (VALENCIA), SPAIN T. (+34) F. (+34) atsa@at3w.com
ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.
ATSTORM v2 ATSTORM v2 is a storm detector that measures the environmental electric field. It is fully automatic, without mobile parts, robust and highly reliable The storm detector ATSTORM v2 basic configuration
More informationPREVENTIVE PROTECTION PROTECCIÓN PREVENTIVA
PREVENTIVE PROTECTION PROTECCIÓN PREVENTIVA R PREVENTIVE PROTECTION ATSTORM v2 is a storm detector that measures the environmental electric field. It is fully automatic, without mobile parts, robust and
More informationLOCAL STORM DATA SHEET
LOCAL STORM DETECTION > Storm detection: who is involved? > Regulations, storm phases and classification of detectors > ATSTORM local thunderstorm detector by measurement of electric field > STORM DETECTION:
More information4-Channel Contact Closure Fiber Link Card System
USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-020 2017A-0330 4-Channel Contact Closure Fiber Link Card System SYSTEM INSTALLATION INFORMATION Description The 4 Channel
More informationMains Supply Guard User Manual
Mains Supply Guard User Manual Version 1.1 2016 Jansen Medicars Jansen Medicars Postbus 49 3600 AA Maarssen Netherlands Tel. +31 30 2613500 Fax. +31 30 2616714 URL www.medicars.com 2016 Jansen Medicars
More informationREA 105 Arc Protection Module. Operator s Manual
REA 105 1MRS 751005-MUM Issued: 20.04.1998 Version: B2/26.5.2000 Checked: Approved: REA 105 We reserve the right to change data without prior notice. Contents: 1. General...4 1.1. Features...4 2. Safety...5
More informationLPI Lightning Warning System - LWS MKIII
LPI Lightning Warning System - LWS MKIII Features Early detection of lightning activity within approximately 25km Alarm signalled when lightning approaches within approximately 8-10km All Clear indication
More informationWIO200 Water In Oil measuring instrument
WIO200 Water In Oil measuring instrument You have made the right decision by choosing a measuring instrument from PAJ Systemteknik. Many customers buy our high standard products every year. There are at
More informationDETECTION AREA OA-FLEX AIR T. Active Infrared Sensor FLEX EYE A X B C D E F G. Emitting area
DETECTION AREA OA-FLEX AIR T BLUEZONE (1st row) A X B C D 2nd row 3rd row E F G 4th row 5th row 6th row I H J : Emitting spots : Emitting spots (can be eliminated) : Detection Area Emitting area [ feet,inch
More informationErP OPERATIONS MANUAL FOR AIR HEATER PROTON EL. PROTON EL Electric heating.
OPERATIONS MANUAL FOR AIR HEATER PROTON EL ErP 2015 05010416 05022916 PROTON EL Electric heating Safety precautions Construction and dimensions Technical parameters Installation EN RU www.protongroup.org
More informationisopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)
T M 1 isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012372 / 03.2015 isopv
More informationManifold Installation Controller MIC-180. Installation and Operation Instructions
Manifold Installation Controller MIC-180 Installation and Operation Instructions For Use With Rheem-Ruud and Paloma Commercial Tankless Water Heaters Table of Contents Safety Information... 1-2 Manifold
More informationAlarm Panel Operating Instructions
Alarm Panel Operating Instructions 1.0 Introduction The Gascon Systems G8850 alarm panel is designed to be used with gas reticulation systems. It is available in single, twin and triple input channel models.
More informationPHOTOELECTRIC AMPLIFIER SERIES
PHOTOELECTRIC AMPLIFIER SERIES Telco s photoelectric amplifier series performs as good today as it did when it first appeared almost 25 years ago. But while the simple design of this iconic product has
More informationPassive infrared ceiling sensor
Passive infrared ceiling sensor 88 Description Control and command device, powered by the SCS BUS, with two different sensors, the combination of which enables managing the light level inside the room,
More informationD564A13002GPS D564A15002GPS Medium Intensity Obstruction Light FAA Compliant
Document Number: 9100-127-2403-99 Revision: A February 03, 2017 Make Your Solutions Even Brigther D564A13002GPS D564A15002GPS Medium Intensity Obstruction Light FAA Compliant User Manual Rev A Table of
More informationGAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for MIWE
GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS Spare parts suitable for MIWE MIWE heating elements/thermostats heating elements heating elements for ovens safety thermostats
More informationInstalling the Cisco ONS FAP-4 Fuse Alarm Panel
Installing the Cisco ONS 15454-FAP-4 Fuse Alarm Panel Product Number: 15454-FAP-4= This document explains how to install, test, operate, and maintain the Cisco ONS 15454-FAP-4 fuse alarm panel. This document
More informationCarbon Monoxide (CO) detection system
1973 Carbon Monoxide (CO) detection system CARB MOXIDE Presentation DESIGN GUIDE AND SELECTI OF CO SYSTEMS The basic purpose of a CO detection system, resides in ensuring a minimum conditions of sanitation
More informationIP Access FACP Adapters. Installation Guide. Entrada2DMK - IP Access FACP Adapter Kit. Kit Includes: Entrada2DMR - IP Access FACP Receiver
IP Access Adapters Installation Guide Entrada2DMK - IP Access Adapter Kit Kit Includes: - IP Access Receiver - IP Access Transmitter I.T.E. 43KC Doc. No. IIEntrada2DMK Rev. 062015 More than just power.
More informationLINEAR HEAT DETECTION CABLE DURÁN-SAFE
LINEAR HEAT DETECTION CABLE DURÁN-SAFE Installation & User Manual 2018 DURAN ELECTRONICA S.L. - All rights reserved www.duranelectronica.com I-manSAFECABLE-v05 TABLE OF CONTENTS Pages 1. INTRODUCTION...
More informationMODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES
MODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES INDEPENDENT ZONE ANNUNCIATION WITH ZONE STATUS INDICATION EIGHT RED LEDS INDICATE ZONE STATUS SELECTABLE NORMALLY-OPEN,
More informationUSER S MANUAL NKP. Duct heater for supply air pre-heating with external control
USER S MANUAL Duct heater for supply air pre-heating with external control CONTENTS Contents... 2 Safety requirements... 2 Purpose... 4 Delivery set... 4 Designation key... 4 Technical data... 5 Design
More informationSentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.
Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH AND LOW LEVEL ALARM 2.2 PUMP DOWN CONTROLLER 2.3
More informationSPACE DETECTOR SP Presentation
SPACE DETECTOR SP2-114 Presentation 1 CONTENTS 2 ULTRASOUND DETECTION 4 2.1 PRINCIPLE 4 2.2 FOR A PERFECT WORKING ORDER 4 3 DETECTOR PLACEMENT 5 3.1 PLACEMENT SITUATION 6 3.2 ZONE OF DETECTION 6 3.3 CITY
More informationCMT MANUAL 6. NMC SENSORS
CMT MANUAL 6. NMC SENSORS TABLE OF CONTENTS INDEMNITY... 5 DOCUMENT INFORMATION... 5 ACKNOWLEDGEMENTS... 5 6.1 INTRODUCTION... 6 6.2 TEMPERATURE AND HUMIDITY SENSORS... 7 6.2.1. TEMPERATURE SENSOR... 7
More informationRFID Card Access Control Unit. Operating Instructions
RFID Card Access Control Unit Operating Instructions 1 1. Product Specification Item Index Operating Voltage 12VDC+10%; Current 1.2A Lock Relay 12VDC/2A Environmental temperature working:0 C~45 C; storage:-10
More informationOperating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm
Operating & Maintenance Manual Alert-4 Ethernet LCD Master Alarm w w w. a m i c o. c o m Contents User Responsibility 4 Introduction 4 Features 5 Description of the Alarm 5 Shipment Details 5 The Alarm
More informationLINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems
LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016 LINETRAXX RCMA420 Residual current monitor for monitoring AC,
More informationRFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.
RFID Non-contact Safety Switches RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance. Based on RFID technology,
More informationOxygen (O2) Single-Point Gas Detection System
Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity
More informationVDS2510 Installation Manual
Video Signal Output No. 1 C N.C Output VDS2510 Installation Manual C N.C Output Viewer 2510-L (Local Unit) Video Signal Output OUTPUT Connections There are two VIDEO OUT connectors. Please connect each
More informationNitrogen Dioxide (NO2) Single-Point Gas Detection System
Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary
More informationREV: 000. Radiant Flash Service Manual
REV: 000 Radiant Flash Service Manual Table Of Contents Introduction 3 Standard Operating Guide 3 Installation 4 External Layout 5-6 Internal Layout 7 Wiring Diagram 8 F.A.Q. 9-12 Comprehensive Parts List
More informationIFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32
1) DESCRIPTION IFP-2.2 Manual IFP-2.8 and IFP-2.2 is a microprocessor controlled Fire Panel with 2 loops intended either for privat Homes & Apartments or larger installations. The two loops are balanced
More informationNGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW
NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The nvent RAYCHEM NGC-40 is a multipoint
More informationIntesisBox BACnet/IP Server - Notifier ID3000 series
IntesisBox Server - Notifier ID3000 series Gateway for integration of Notifier ID3000, ID3002, ID50 and ID60 fire panels into enabled control systems. Integrate your Notifier fire panels into your BACnet
More informationNGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3
NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic
More informationLeakFilm. Protecting your high-tech assets with innovative, user-friendly technology for liquid leak detection
Protecting your high-tech assets with innovative, user-friendly technology for liquid leak detection The most reliable, durable, cost-effective solution Unlike some other forms of liquid leak detection,
More informationCO2 Monitor Operating Instructions
1. Product Overview CO2 Monitor Operating Instructions Model: RAD-0102-6 Remote CO2 Storage Safety System Thank you for selecting the RAD-0102-6 CO2 Storage Safety Alarm. This monitor is designed to detect
More informationEnglish CST55 CSS10 CSB5 CSC55 JBL CINEMA SOUND CST55, CSB5, CSC55, CSS10 OWNER S GUIDE
English CST55 CSS10 CSB5 CSC55 JBL CINEMA SOUND CST55, CSB5, CSC55, CSS10 OWNER S GUIDE READ FIRST! Important Safety Precautions! 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings.
More informationDigi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input
User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with
More informationSAFETY, INSTALLATION AND MAINTENANCE INSTRUCTIONS
AQUARIUM LED SAFETY, INSTALLATION AND MAINTENANCE INSTRUCTIONS FULL ONLINE INSTRUCTIONS: www.arcadia.systems READ AND FOLLOW ALL SAFETY INSTRUCTIONS KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE DANGER-
More informationIntelligent addressable fire alarm control panel
Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity
More informationOperating Instructions
87 x 125mm Operating Instructions BEFORE OPERATING THIS PRODUCT, READ, UNDERSTAND, AND FOLLOW THESE INSTRUCTIONS. Be sure to save this booklet for future reference. www.facebook.com/denverelectronics 1.
More informationOMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments
OMC-158-2 Ex interface unit Manual Version 1.2 August 2017 Author: Observator Instruments Revisions: 0.1 (October 2016) First issue 0.2 (December 2016) Prototype 0.3 (January 2017) Test release 1.0 (March
More informationMulti-Graphic MCPB & Series 115B, 2223R, & 2233R
Multi-Graphic MCPB & Series 115B, 2223R, & 2233R Installation and User Manual 2009 Bogen Communications, Inc. All rights reserved. Specifications subject to change without notice. 54-5875-03B 0903 Notice
More informationUniversal Gas Detector
Universal Gas Detector Instruction Manual PureAire Monitoring Systems, Inc. 557 Capital Drive Lake Zurich, Illinois 60047 Phone: 847-726-6000 Fax: 847-726-6051 Toll-Free: 888-788-8050 pureairemonitoring.com
More informationTCS5JBL & TCS5JBLA. Low-Voltage Top-Up Switch
3P Technik TCS5JBL & TCS5JBLA Low-Voltage Top-Up Switch Installation and Operation Manual 3P TCS5JBL/TCS5JBLA Page 1 11/09/16 Table of Contents Description Of Operation...2 Installation...2 Safety Precautions...2
More informationInstruction FH-CWP Thermostat
Instruction FH-CWP Thermostat Index Instruction FH-CWP Thermostat 1. Functional Overview.......................... 3 2. Mounting..................................... 4 3. Installation....................................
More informationT6865 Series Large LCD Digital Thermostat 24 VAC 2-pipe fan coil control
T6865 Series Large LCD Digital Thermostat 24 VAC 2-pipe fan coil control Application Data sheet T6865 digital thermostats are designed for application of 3-speed fan and modulating valves in fan coil system.
More informationCentro-Matic Automated Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
More informationSURROUND CINEMA SPEAKERS SCS160 OWNER S GUIDE
SURROUND CINEMA SPEAKERS SCS160 OWNER S GUIDE READ FIRST! Important Safety Precautions! 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not
More informationUSER MANUAL. SAFERA Connection Hub for SAFERA Siro IN-line and Siro R
Power IN (SAFERA Power Supply) Dimensions 110 x 55 x 22 mm AUX IN 1 = Yellow OUT 1 = Green IN 2 = White OUT 2 = Brown CTU Optional extinguisher unit Power OUT (SAFERA Siro IN-line or Siro R sensor unit)
More informationTECHNOLOGIES FOR LIGHTNING PROTECTION LOCAL STORM DETECTION AIR TERMINALS AND ACCESSORIES TRANSIENT OVERVOLTAGES PERMANENT OVERVOLTAGES WELDING
TECHNOLOGIES FOR LIGHTNING PROTECTION LOCAL STORM DETECTION AIR TERMINALS AND ACCESSORIES EARTHING EXOTHERMIC WELDING TRANSIENT OVERVOLTAGES PERMANENT OVERVOLTAGES TECHNOLOGIES FOR LIGHTNING PROTECTION
More informationVPS3 Installation Manual
1-512-756-1678 VPS3 Installation Manual VPS3 Viewer (Local Unit) VPS3 Sender (Remote Unit) Content Introduction...2 Features...2 Packing Checklist...2 Patents...2 Limited Warranty...2 Overall Certificate...3
More informationSensors SR Programming manual
Sensors SR510000 Index 1 GENERAL DESCRIPTION... 3 2 TECHNICAL INFORMATION... 4 3 PROGRAMMING... 5 3.1 APPLICATION PROGRAM INFORMATION... 5 3.2 COMMUNICATION OBJECTS TABLE... 5 3.3 OBJECTS DESCRIPTION...
More informationOG5000 Ozone Generator Model OG5000B-A. User Manual
OG5000 Ozone Generator Model OG5000B-A Copyright 2017 610-0082-01H DCN7785 Teledyne API 25 September 2017 Contents CONTENTS... 1 FIGURES... 2 TABLES... 2 1. GENERAL PRECAUTIONS... 3 Safety... 5 Safety
More informationBC-R10 Series. Burner Controllers
No. CP-SS-1885E BC-R10 Series Burner Controllers Summary BC-R10 Series burner controllers are combustion safety controllers specifically designed for batch operation (systems which start and stop at least
More informationWIO500 and WIOI500 Water in oil sensor
WIO500 and WIOI500 Water in oil sensor User manual Rev. 1.08 111881-942 Rev. 1.08 User manual 500 Date: 2017-01-20 03-01-0501-CRJ-04 Side 1 af 79 Table of contents Table of contents... 2 Introduction...
More informationXUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12
Characteristics photo-electric sensor - XUX - multi - Sn 0..40m - 12..24VDC - M12 Complementary Enclosure material Lens material Maximum sensing distance Output type Add on output Status LED [Us] rated
More informationLUCCI AIRFUSION BREEZE WALL FAN INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE
LUCCI AIRFUSION BREEZE WALL FAN INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0- E N ( 0 8 / 2 0 1 8 ) THANK YOU
More informationStego accessories for cabinets
www.klinkmann.com Stego accessories for cabinets page Small semiconductor Heater RC 016 2 Touch-Safe Small Heater CSK 060 3 Semiconductor Heater HG 140 4 Hazardous area Heater CREx 020 5 Touch-Safe Heater
More informationP4200PM / P5000PM Remote Air Dryer User s Guide
P4200PM / P5000PM Remote Air Dryer User s Guide 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS P4200PM / P5000PM Air Dryer! We here at PUREGAS are very proud of our products
More informationIndex Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:
Systems Index Systems - Systems Systems...1 -.16 General information Description...1 System description...2 Overview...3 Ordering details Arc monitor with detectors...4 Current sensing unit...5 Technical
More informationModBus DE-1 INSTALLATION AND USER MANUAL
ModBus DE-1 INSTALLATION AND USER MANUAL INTESIS Software, SL Distributed by DURAN ELECTRONICA S.L Tomás Bretón 50 28045 MADRID, España duran@duranelectronica.com www.duranelectronica.com 2 2010 DURAN
More informationHigh Pressure Conductivity Monitor
Product Data Sheet PDS 71-EDS880/1/rev.A August 2006 Model EDS880/1 High Pressure Conductivity Monitor COMPLETE SYSTEM FOR THE DETERMINATION OF CONDUCTIVITY IN HIGH PRESSURE SYSTEMS SENSOR INSTALLS DIRECTLY
More informationCommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET
CommStat 6 Controller for Redundant HVAC Systems PRODUCT DATA SHEET General Description The CommStat 6 HVAC controller is designed for controlling up to six redundant air conditioners in an E-House or
More informationOPTISENS TUR 2000 Technical Datasheet
OPTISENS TUR 2000 Technical Datasheet Sensor for turbidity measurement in water and wastewater Rugged design for harsh applications Integrated transmitter with direct 4...20 ma output Near infrared light
More informationHOME AUTOMATION, INC. Lumina and Lumina Pro Lighting and Automation System. Quick-Start Installation Guide
HOME AUTOMATION, INC. Lumina and Lumina Pro Lighting and Automation System Quick-Start Installation Guide Document Number 44I00-1 Rev. 2.12 February, 2006 For complete operation and programming instructions,
More informationDWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670
Bulletin AV-670 Series 670 Hood Monitor Specifications - Installation and Operating Instructions DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Phone: 219/879-8000 Fax: 219/872-9057
More informationInstallation and Operating Instructions
Installation and Operating Instructions Dedicated Recirc System Standard Hot Water Circulation Pump Dedicated Recirc System Standard Step 1. Choose the appropriate place to install the pump and Flow Monitor:
More information4 Channel Contact Closure SFP DIN Fiber Link System
USER GUIDE The leader in rugged fiber optic technology. U- 07A-0707 Channel Contact Closure DIN Fiber Link System Installation and Configuration Information Description The system provides transmission
More informationInstruction Manual Model Backup Switch, 1 for 8
Instruction Manual Model 2582-282 Backup Switch, 1 for 8 December 2011, Rev. 0 MODEL 2582 SWITCH CROSS TECHNOLOGIES INC. SWITCH ALARM PSA PSB ALARM OFFLINE ONLINE UNIT STATUS 1 2 3 4 5 6 7 8 BU PROT MODE
More informationInstallation manual Mini Comfort 50 S/L 07/ V EN
Installation manual Mini Comfort 50 S/L 07/2015 - V 1.1 - EN www.veneco-ventilation.be Veneco ventilation by Elek Trends Productions nv Blauwfazantjesstraat 4 B - 7700 Moeskroen Tel. +32 (0)56 48 15 90
More informationSERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A
OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 Indoor unit service manual MSZ-DM VA Series (OBH750) CONTENTS 1. TECHNICAL CHANGES 2 2. PART NAMES
More informationWIO 200B and WIOI200B Water in oil sensor
WIO 200B and WIOI200B Water in oil sensor User manual Rev. 1.11 111881-944 Rev. 1.11 WIO200B User manual Date: 2017-01-20 03-01-0501-CRJ-04 Side 1 af 61 Table of contents Table of contents... 2 Introduction...
More informationAll- IN- ONE PROXIMTY STAND ALONE CONTROLLER OPERATION MANUAL MODEL: HA3021 VERSION: 3.60
All- IN- ONE PROXIMTY STAND ALONE CONTROLLER OPERATION MANUAL MODEL: HA3021 VERSION: 3.60 HEART ENTERPRISE CO. LTD. HEART ENTERPRISE CO., LTD. 0 Table of Contents Features 2 Specification 3 Wiring Description
More informationActive Infrared Sensor OA-EDGE1/EDGE2. to the sensor module d4 = Distance from the pivot edge to the sensor module n = Number of sensor modules h
DETECTION AREA Active Infrared Sensor OA-EDGE1/EDGE Recommended installation position Leading edge d3 w Pivot edge W Door widt Mounting eigt / d Detection area widt d3 Distance from te leading edge to
More informationVAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1
Model TRO24T4XYZ1 Description The TRO24T4XYZ1 is a combination controller and thermostat. The VAV Thermostat Controller is designed for simple and accurate control of any variable air volume box in a number
More informationRadio fire warning panel SRC 3000
Radio fire warning panel SRC 3000 6 zone radio fire warning panel Operating instructions Version 1.2 Art. 32487 detectomat GmbH Headquarter: Phone: +49 (0) 4102-2114-60 An der Strusbek 5 Fax: +49 (0) 4102-2114-670
More informationCCS-100. Installation Manual
Installation Manual CCS-100 WARNING: DO NOT ATTEMPT TO INSTALL USE THE FIXTURE WITHOUT READING THE INSTALLATION INSTRUCTIONS AND SAFETY LABELS COMPLETELY. Failure to adhere to these instructions could
More informationApplications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements
INDEX 1 NETIC... 2 2 Door/Window detector MINI... 2 3 FOUR sensor... 3 4 Smoke detector... 3 5 Flood detector... 4 6 ILLumination sensor... 4 7 Lamp holder... 5 8 Siren... 5 9 Power meter & switch... 6
More informationLightning Warning System: LWS MK-II. User's Guide. KOREA EMI Technologies Co.,Ltd , Jangam-ri, Majang-myeon, Icheon-si, Gyeonggi-do, Korea
User's Guide CONTENTS FEATURES WHAT YOU NEED TO GET STARTED INSTALLATION DETAILS Installing the Antenna Installing the External Alert Siren The main console OPERATING PROCEDURE Power On Routine Push Buttons
More informationSmart Series TAS-05-11, TAS-05-12
Smart Series TAS-05-, TAS-05-2 Temperature Alarm & System Control Module User s Manual D-M-E Company ED-0063-OT-002-A D-M-E TAS User s Manual Page Copyright D-M-E Company 2000. All rights reserved. D-M-E
More informationDIVA8MG2. Compact PAVA System Master Unit. DIVA8 System
DIVA8MG2 Public Address - Voice Alarm Audio Distribution over IP Commercial Audio Intelligent Acoustic Solutions Intercommunication Loudspeakers Compact PAVA System Master Unit DIVA8 System DIVA8 system
More informationQUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS
QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1-316-832-4357
More informationSecuriSens LIST Product Catalogue 2015
SecuriSens LIST Product Catalogue 2015 Content 1. Processor Units... 5 2. Cable... 7 3. Accessories List... 8 4. Spare Parts... 13 5. Services... 15 6. Product Type Index... 16 2 Securiton Product Catalogue
More informationRig Protector. Multipoint Critical Gas Detection and Monitoring System
Rig Protector Multipoint Critical Gas Detection and Monitoring System Rig Protection Device Protecting Personnel from Hazardous Gases RC Systems has engineered and manufactured industrial electronic products
More informationSuperdew 3. Hygrometer. Operating Instructions
Superdew 3 Hygrometer Operating Instructions Shaw Moisture Meters (UK) Ltd Len Shaw Building Bolton Lane Bradford BD2 1AF England t. +44 (0) 1274 733582 f. +44 (0) 1274 370151 e. mail@shawmeters.com www.shawmeters.com
More informationMTRA-FSP Level Control Relay. Installation & Operation Manual
MTRA-FSP Level Control Relay Installation & Operation Manual This Manual is the support documentation for the installation, commissioning and operation of the MTRA-FSP Level Control Relay. Document Revision
More informationEx LED light fittings
About us TEP Ex is a regional leader in manufacturing of explosion-protected electrical equipment. Through continuous development of new products and markets, modernization of technology and investment
More informationROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A
SPECIFICATIONS (Revised 1/12/2006) ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A The system shall operate on the principle of light absorption. It shall consist
More informationPRODUCT: SEL-SV-MCQ-O5- K6 VERSION TECHNICAL SHEET 1/5 SAC
PRODUCT: SEL-SV-MCQ-O5- K6 VERSION 3. TECHNICAL SHEET /5 SAC 55 39-66 APPLICATION Flame presence signal sensor-transmitter recommended for single- or multiple-burner systems for industrial or commercial
More informationM770 ph Controller Owner s Manual
M770 ph Controller Owner s Manual Table of Contents I. Introduction page 2 A. Water Chemistry page 2 B. Safety page 3 C. System Components page 4 D. Specifications page 7 E. Controller Panel Descriptions
More informationP6500W Air Dryer User s Guide
P6500W Air Dryer User s Guide 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS P6500W Air Dryer! We here at PUREGAS are very proud of our products and we are committed to
More informationSentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.
Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH Liquid Level Alarm 2.2 LOW Liquid Level Alarm 3. INSTALLATION...
More informationInstructions for installation and use RE/I. Industrial electric heater for swimming pool
Instructions for installation and use RE/I Industrial electric heater for swimming pool Réf. : N.D.010.A.EN Ver. 06-2010 1. Installation... 2 1.1 General... 2 1.1.1 Precautions... 2 1.1.2 General terms
More informationNon-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION
Sensing and Internet of Things Non-Contact Switches FF6 Series DESCRIPTION Honeywell FF6 Series are magnetically actuated noncontact safety limit switches for use in machine guarding applications, designed
More informationHeating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App
Heating is great when you control it. USER MANUAL Wireless Programmable Room Thermostat Model No.: LS99111010 Scan for App Contents 1. Overview... 01 2. System Installation... 02 2.1 Install and Wiring
More information