CHEAT SHEET: SPECTRA V2.1

Size: px
Start display at page:

Download "CHEAT SHEET: SPECTRA V2.1"

Transcription

1 CHEAT SHEET: SPECTRA V2.1 Zone mapping Device connected To which input? NO ATZ WITH ATZ CONTROL PANEL INPUT 1= ZONE 1 ZONE 1 & 6 INPUT 2= ZONE 2 ZONE 2 & 7 INPUT 3= ZONE 3 ZONE 3 & 8 INPUT 4= ZONE 4 ZONE 4 & 9 INPUT 5= ZONE 5 ZONE 5 & 10 INPUT 6= N/A N/A INPUT 7= N/A N/A KEYPAD ZONE 1= ZONE 6 ZONE 11 ZONE 2= ZONE 7 ZONE 12 ATZ = Zone Doubling The Zone doubling feature allows you to install two devices per hardwired input terminal. Each detection device will have its own zone, display its own zone status on the keypad and send separate alarm codes for each zone. Each zone is differentiated by a different resistor value. EXPANSION INPUT 1= ZONE 8 ZONE 13 INPUT 2= ZONE 9 ZONE 14 INPUT 3= ZONE 10 ZONE 15 INPUT 4= ZONE 11 ZONE 16 INPUT 5= ZONE 12 N/A INPUT 6= ZONE 13 N/A INPUT 7= ZONE 14 N/A INPUT 8= ZONE 15 N/A *A location is referred to as a section. *Value or data is referred to as an option. How to enter programming: PRESS THE ENTER KEY ENTER THE INSTALLER CODE (DEFAULT: 0000). ENTER LIGHT WILL FLASH (INDICATING THAT A SECTION NUMBER MUST BE ENTERED) ENTER 3 DIGIT SECTION. ENTER LIGHT WILL TURN ON SOLID (INDICATING THAT YOU ARE AT A SECTION NUMBER) ENTER DATA AS REQUIRED * PRESS CLEAR ONCE STEP BACK ENTER LIGHT FLASHING 1

2 How to program zones: GET IN PROG. MODE: ENTER SECTION NUMBER (e.g: 001 = Zone 1) ENTER ONE DIGIT FROM THE ZONE DEFINITION TABLE (i.e. instant, follow (handover), entry) ENTER ONE DIGIT FROM THE PARTITION ASSIGNMENT TABLE (you are assigning hat zone to an area/partition) STEP 5: SELECT ONE OR MORE OPTIONS FROM THE ZONE OPTIONS TABLE (This table is a toggle ON/OFF feature.) I.e. if key 2 is on = Bypassable zone, this means it is enabled. If you want to disable it, press key 2, and the led will turn off. This disables that option. STEP 6: PRESS ENTER SAVE *PANEL AUMATICALLY JUMPS NEXT ADDRESS IN ZONE PROGRAMMING System timers: 069 ENTRY DELAY 1 *45 SECS 071 EXIT DELAY 1 *30 SECS 078 NUMBER OF RINGS *DISABLED 087 AU TEST REPORT DAYS *DISABLED 110 AU TEST REPORT TIME *DISABLED *Bold is default setting Programmable outputs. EVENT GROUP SUB-GROUP PARTITION 120 ACTIVATION EVENT PULSED OR STEADY ALARM 121 DEACTIVATION EVENT PARTITION STATUS DISARM Activation event is when you want the PGM (programmable output) to turn on. Deactivation event is when you would like the PGM to turn off. *The PGM provides a negative when turned on. AUX POSITIVE POS + (STROBE) PGM - *The programming example given above is for a strobe activation. 2

3 System option: The features within these sections are enabled/disabled by toggling the key options on/off. SECTION 127: 1 PARTITIONING *DISABLED SECTION 130: 1 ONE UCH ARMING *DISABLED 2 ONE UCH STAY ARMING *DISABLED 3 ONE UCH FORCE ARMING *DISABLED 4 ONE UCH BYPASS *DISABLED SECTION 131: 1 REPORT DISARMING *ONLY AFTER ALARM SECTION 132: 4 END OF LINE RESISRS *NO EOL 5 ZONE DOUBLING (1728) SECTION 135 : 3 REPORTING (DIALER) *DISABLED SECTION 136: 3 CONTACT ID REPORT CODES *ALL CODES AU SECTION 140: REPORTING FORMATS FOR TEL 1/ TEL 2 *5= CONTACT ID 6= PAGER FORMAT (USED FOR PERSONAL DIALLING) SECTION 143/144: ACCOUNT NUMBERS FOR PARTITION 1 & 2 SECTION 151/152: TEL NUMBER 1 & 2 FOR CENTRAL STATION OR PERSONAL DIALLING *Bold is default setting PROGRAMMING ACCESS CODES: STEP 5: SECTION 302: MASTER CODE 1 SECTION 303: MASTER CODE 2 SECTION 304 : USER CODE 4 SECTION 348: USER CODE 48 *Refer to page 18 of programming guide PRESS ENTER KEY IN MASTER CODE KEY IN 3 DIGIT USER LOCATIONS KEY IN NEW CODE ENTER LIGHT WILL FLASH, WAITING FOR NEW USER LOCATION (STEP 3). END, PRESS CLEAR. PROGRAM IN USER CODE OPTIONS 3

4 SECTION 281: INSTALLER CODE Wireless devices: PIR s and transmitters PIR s & Detectors: GET IN PROGRAMMING MODE KEY IN 3 DIGIT SECTION NUMBER (Refer to page 24 of prog. Guide) ENTER IN SERIAL NUMBER OF PIR OR TRANSMITTER For Example: SECTION 601 SERIAL NUMBER = EXPANSION INPUT 1 SECTION 602 SERIAL NUMBER = EXPANSION INPUT 2 SECTION 608 SERIAL NUMBER = EXPANSION INPUT 8 (The serial number is found on the PCB of the device.) ENABLE ZONE THAT RELATES THAT EXPANSION INPUT (Refer to zone mapping table) WIRELESS DEVICES: REMOTE CONTROLS ASSIGN REMOTE CONTROL 3 DIGIT USER LOCATION Ie. SECTION 701: _/_/_ REMOTE CONTROL 1 SECTION 702: _/_/_ REMOTE CONTROL 2 SECTION 708: _/_/_ REMOTE CONTROL 8 *REFER PAGE 26 OF PROGRAMMING GUIDE ASSIGN FEATURE OPTIONS YOUR BUTNS Ie SECTION 711: 1 / 5 / _ / _ / _ / _ / _ / _ / BUTN- A B C D A+B C+D A+C B+D FOR REMOTE CONTROL 1 SECTION 712: REMOTE CONTROL No 2 OPTIONS SECTION 718: REMOTE CONTROL No 8 OPTIONS Programmed here is: (example only) Button A to operate as Regular Arm = 1 Button B is to operate as Disarm = 5. If you want to only use button A and B, then press enter once you have added the options you require. PROGRAM IN THE REMOTES Ie SECTION 731: FOR REMOTE CONTROL 1. PRESS BUTN A TWICE (a confirmation beep will be heard). SECTION 732: FOR REMOTE CONTROL 2 SECTION 738: FOR REMOTE CONTROL 8 4

5 ZONE EXPANSION MODULES: ZX-4 OR ZX-8: ENTER PROGRAM MODE SECTION 650: OPTION 1 IS ENABLE END OF LINE SECTION 651: OPTION 1 IS ENABLE EXPANSION INPUT 1 OPTION 2 IS ENABLE EXPANSION INPUT 2 OPTION 8 IS ENABLE EXPANSION INPUT 8 (*OPTION 650 AND 651 IS A GGLE ON/OFF SECTION) ENABLE EXPANSION INPUT ZONES (REFER ZONE MAPPING TABLE) PERSONAL DIALLING: SECTION 135: ENABLE OPTION 3 REPORTING SECTION 136: DISABLE OPTION 3 CONTACT ID CODES SECTION 140: 6 / 6 PAGER FORMAT SECTION 143: 1234 PARTITION 1 ACCOUNT NUMBER STEP 5: SECTION 151 & 152: PROGRAM TELEPHONE NUMBER FOLLOWED BY TROUBLE TROUBLE STEP 6: SECTION : PROGRAM IN A 1 / 1 IN APPROPRIATE REPORTING CODE (*Page 16 of programming guide) STEP 7: SECTION 080: SET APPROPRIATE MAX. DIALING ATTEMPTS 5

SPECTRA 1728, 1738 CHEAT SHEET:

SPECTRA 1728, 1738 CHEAT SHEET: SPECTRA 1728, 1738 CHEAT SHEET: ZONE MAPPING: Device connected To which input? NO ATZ WITH ATZ CONTROL PANEL INPUT 1= ZONE 1 ZONE 1 & 6 INPUT 2= ZONE 2 ZONE 2 & 7 INPUT 3= ZONE 3 ZONE 3 & 8 INPUT 4= ZONE

More information

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide Digiplex System V2.14 / V2.2ACC Control Panel Programming Guide Table of Contents Getting Started...2 What Do I Do First?...2 How Do I Program the Control Panel?...2 Single Digit Entry Method...2 Multiple

More information

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX PROGRAMMING GUIDE SPECTRA CONTROL PANELS V1.2 1725, 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX TABLE OF CONTENTS HOW DO I PROGRAM THE SYSTEM?... 4 Single Digit Data Entry Method (Hexadecimal

More information

1728EX, 1728, 1738EX AND 1738 SYSTEM PROGRAMMING GUIDE

1728EX, 1728, 1738EX AND 1738 SYSTEM PROGRAMMING GUIDE DEFAULT INSTALLER CODE 0000 / 000000 (see section [281] on page 17) DEFAULT SYSTEM MASTER CODE 1234 / 123456 (see section [301] on page 17) HOW DO I ENTER PROGRAMMING MODE? STEP 1: Press [ENTE R] STEP

More information

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4 Programming Guide We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

Sentry 4 Zone Alarm Panel User Manual

Sentry 4 Zone Alarm Panel User Manual TM TM Sentry 4 Zone Alarm Panel User Manual PLEASE NOTE: A 16Vac / 16VA Transformer MUST be used with this product. Contents 1. Introduction. 2. Programming a Remote. 3. Deleting all Remote s. 4. The siren

More information

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160 All-In-One Wireless Security System V3.2 Programming Guide Model # MG6130 / MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

DSC PowerSeries NEO Quick Start Guide

DSC PowerSeries NEO Quick Start Guide DSC PowerSeries NEO Quick Start Guide WE DO NOT RECOMMEND BEING IN ANY PROGRAMMING SECTION THAT IS NOT IN THIS GUIDE UNLESS YOU FULLY UNDERSTAND THE FUNCTION OF THAT SECTION. Doing so may cause problems

More information

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master) User Codes (1-6 digits) Access Levels Access Levels + Time Control User 1 (Master) 1 1 2 3 25 49 73 0 User 2 2 26 50 74 0 User 3 3 27 51 75 0 User 4 4 28 52 76 0 User 5 5 29 53 77 0 User 6 6 30 54 78 0

More information

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide MG6250 2-Partition 64-Zone Wireless Console with GPRS/GSM Version.6 Section Programming Guide Things You Need to Know About this Programming Guide The MG6250 All-in-one Wireless Console can be programmed

More information

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual WIC-16Z4P WIC-5Z2P Installation & Operation User Manual Page : 1/34 INDEX # Function Page 1 Abort Current Communication and Clear Reporting Queue (*59) 13 2 Abort Current Communications (*59) 10 3 Account

More information

Control/Communicator Installation Manual

Control/Communicator Installation Manual DAS NETWORX NX-12 Control/Communicator Installation Manual General Description...2 Ordering Information...2 Option Definitions...3 Programming the LED Code Pads...5 Programming the NX-12...9 Types of Programming

More information

EVO192 v3.0 Fire and Burglary What s New

EVO192 v3.0 Fire and Burglary What s New EVO192 v3.0 Fire and Burglary What s New Compatibility: EVO192 v3.0 TM50 v1.31 K641 v2.41 Overview: CP-01 Compliancy Wiring Diagram The following sections/options have been added to the EVO192 panel. They

More information

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel CAUTION: It is advised that an experienced alarm installer programs the panel as further programming may be required

More information

Property of Monitronics Inc

Property of Monitronics Inc Enter Program Program Location 1. Hold 8 key for 3 seconds, keypad will beep 2. Enter 4 5 6 7 8 9, display should show dash on display 1. Press [B/A] key display will show 3 dashs 2. Enter 3-digit location

More information

HILLS Series LED Code Pad User Manual

HILLS Series LED Code Pad User Manual HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2

More information

System Programming Guide

System Programming Guide & System Programming Guide Software Versions 4.4 (728ULT) and 4.1 (738ULT) Installer Code (Default - 728 Ultra: 282828; 738 Ultra: 383838) Full access to programming, except user access codes (PINs). No

More information

CC488. Quick Reference Guide Solution Ultima 880

CC488. Quick Reference Guide Solution Ultima 880 CC488 EN Quick Reference Guide Solution Ultima 880 CC488 Quick Reference Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty

More information

8-zone Expansion Module

8-zone Expansion Module 8-zone Expansion Module APR3-ZX8 SECTION [001] : General Options Option OFF ON [1] Tamper Recognition ON = Input 8 (Z8) becomes tamper input = Default setting Disabled Enabled [2] PGM Deactivation After

More information

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom CC880/LP880, SC8016 EN Operators Guide Solution-16, Solution-16 Safecom CC880/LP880, SC8016 Operators Guide EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch

More information

Power Wave Zone Alarm Panel V8.5. Installation Manual

Power Wave Zone Alarm Panel V8.5. Installation Manual Power Wave - 8 8 Zone Alarm Panel V8.5 Installation Manual 7 December 2001 Crow (Aust) Electronic Engineering Pty Ltd Corporate Head Office: 429 Nepean Hwy, Brighton East, Vic., 3187 Australia Phone: +61

More information

CC408. Quick Reference Guide Solution 880

CC408. Quick Reference Guide Solution 880 CC408 EN Quick Reference Guide Solution 880 CC408 Quick Reference Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd ( Bosch

More information

System Introduction. 1.1 Specifications S E C T I O N 1

System Introduction. 1.1 Specifications S E C T I O N 1 System Introduction S E C T I O N 1 1.1 Specifications Control Panel Specifications Flexible Zone Configuration: 8 Fully Programmable Zones 37 Access Codes: 32 User, 1 System Master, 2 Partition Master

More information

Digiplex Control Panel (DGP-848) - V4.0

Digiplex Control Panel (DGP-848) - V4.0 Digiplex Control Panel (DGP-848) - V4.0 DGP-848 Reference and Installation Manual TABLE OF CONTENTS INTRODUCTION... 4 1.0 1.1 Features... 4 1.2 Specifications... 4 INSTALLATION... 5 2.0 2.1 Location &

More information

3 User s settings. 3.3 Internal clock setting

3 User s settings. 3.3 Internal clock setting 2.9 Subsystem arming In a large building a sub control panel can be enrolled to the JA-63. The subsystem reports all alarms and failures to the main system. The installer can program if the systems will

More information

4-PGM Expansion Module

4-PGM Expansion Module 4-PGM Expansion Module APR3-PGM4 = Default setting SECTION [001] : General Options SECTION [002] : PGM Options Option OFF ON Option OFF ON [1] Future Use N/A N/A [1] PGM1 Deactivation After Deactivation

More information

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION...P.2 2. STANDARD AND OPTIONAL PARTS LIST...P.2 3. FEATURE DEFINITIONS...P.3 4. TERMINAL DRAWING AND

More information

System Introduction. 1.1 Specifications

System Introduction. 1.1 Specifications System Introduction S E C T I O N 1 1.1 Specifications Downloading Software Support PC585 uses DLS-1 v6.5 and up. Flexible Zone Configuration Four fully programmable zones; system expandable to eight zones

More information

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide ICP-CC488 EN User s Guide ICP-CC488 Control Panel ICP-CC488 User's Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems, Inc. ( Bosch

More information

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging 1.1 Specifications System Introduction S E C T I O N 1 Control Panel Specifications Flexible Zone Configuration: 8 Fully Programmable Zones 38 Access Codes: 32 User, 1 System Master, 2 Partition Master,

More information

Contents. Glossary

Contents. Glossary Contents Glossary ------------------------------------------------------------------------------------------------------ 6 1. Introduction to the IDS 1632 -------------------------------------------------------------

More information

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE... TABLE OF CONTENTS...Glossary of terms...2...code Pad Diagram...3 Understanding the Code Pad lights...4 Code Pad tones...5 Fully arming the system On MODE...6 Fully arming the system - Quick Arm MODE...6

More information

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel CAUTION: It is advised that an experienced alarm installer programs the panel as further programming may be required

More information

Power Wave. 8 Zone Control Communicator. Crow Electronic Engineering P/L. Ver:8.54. Installation & Programming Guide.

Power Wave. 8 Zone Control Communicator. Crow Electronic Engineering P/L. Ver:8.54. Installation & Programming Guide. Power Wave 8 8 Zone Control Communicator Crow Electronic Engineering P/L Ver:8.54 Installation & Programming Guide 8 November 2000 Crow ( Aust ) Electronic Engineering Pty Ltd Corporate Head Office: 429

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING -961212-0004 SOFTWARE VERSI 3.10 CTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)

More information

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147) -961112-0003 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3

More information

Quick Programmer s Manual

Quick Programmer s Manual Version 2.604 (31/03/05) p1 Quick Programmer s Manual 2005. Inner Range Pty. Ltd. Part Number: 630048V2 p2 Version 2.604 (31/03/05) TABLE OF CONTENTS. 1. PROGRAMMING FLOWCHART. The following flowchart

More information

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP PROGRAMMING STARTS Entering Installer mode If you want to get into program mode press followed by your installer code, default set to 000000

More information

Solution Ultima 862 Operators Manual ISSUE 1.10

Solution Ultima 862 Operators Manual ISSUE 1.10 Solution Ultima 862 Operators Manual ISSUE 1.10 Solution Ultima 862 Operators Manual Copyright 2001 by, SYDNEY, AUSTRALIA Document Part Number MA486O DOCUMENT ISSUE 1.10 Printed 24 April 2001 This documentation

More information

Solution 6+6 Wireless On/Off Installation Manual ISSUE 1.20

Solution 6+6 Wireless On/Off Installation Manual ISSUE 1.20 Solution 6+6 Wireless On/Off Installation Manual ISSUE 1.20 MA670I This page has been included for you to cut out and insert into the spine of the folder Solution 6+6 Wireless On/Off Installation Manual

More information

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1 1.1 PC5015 Specifications System Introduction S E C T I O N 1 Flexible Zone Configuration: 8 Fully Programmable Zones 38 Access Codes: 32 User, 1 System Master, 2 Partition Master, 2 Duress and 1 maintenance

More information

Solution-6 Operators Manual Page 1 Preface Congratulations on selecting the Solution-6 security control system for your installation. So that you can obtain the most from your unit, we suggest that you

More information

JA-63 Profi User manual

JA-63 Profi User manual JA-63 Profi User manual Contents: 1 Limited warranty... 2 2 Indicators... 3 3 Controlling the system... 4 3.1 Arming... 5 3.2 Disarming... 6 3.3 Panic Alarm... 6 3.4 To stop ALARM... 6 3.5 Home arming...

More information

Solution Ultima Series Operators Manual ISSUE 1.00

Solution Ultima Series Operators Manual ISSUE 1.00 Solution Ultima Series Operators Manual ISSUE 1.00 Solution Ultima Series Operators Manual Copyright 1998 by, SYDNEY, AUSTRALIA Document Part Number MA488O DOCUMENT ISSUE 1.00 Printed 16 February 1999

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING -961212-0004 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. ( 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2) Connect

More information

VAP304 PRO INSTALLATION & OPERATION MANUAL

VAP304 PRO INSTALLATION & OPERATION MANUAL VAP304 PRO INSTALLATION & OPERATION MANUAL Panic Fire Duress Program Bypass Report Chime Test Memory B A D C Program Chime Panic Duress Exit Fire Report Bypass Memory Test Reset Password Exit Reset Password

More information

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0 M2M Services Ltd. RControl Alarm - Installer Manual V 1.0 Content Content... 2 Wiring the power supply module... 3 Wiring a siren... 3 SMARTEnroll self-learning zones... 3 Wireless keyfobs... 3 Supported

More information

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0 User s Guide SUB-MA7240O-0001.OG.Solution40-111.doc Created: 6/05/03 Last Updated: 23/09/03 MA7240AO-0001 Version 1.0 2 Table Of Contents User List...6 Quick Reference..7 Features...7 Keypad User's Guide...8

More information

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION... 2 2. STANDARD AND OPTIONAL PARTS LIST... 2 3. FEATURE DEFINITIONS... 3 4. TERMINAL DRAWING AND SPECIAL

More information

Installation & Programming Guide

Installation & Programming Guide Alert Version 8 Zone Control Arrowhead Alarm Products Ltd Installation & Programming Guide Proudly Designed and Manufactured in New Zealand Arrowhead Alarm Products Ltd PHONE: (09) 579 7506 FAX: (09) 579

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING 48ESEP-01 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)

More information

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. SK618 WIRELESS ALARM SYSTEM WITH AUTO DIALER OWNER'S MANUAL Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. If at any time during your installation you have any questions

More information

Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10

Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10 Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10 MA660I Solution 6+6 This page has been included for you to cut out and insert into the spine of the folder Wireless AE Installation Manual ISSUE

More information

QUICK USER MANUAL. Alarm Control Panel. The full user manual and other manuals are available on

QUICK USER MANUAL. Alarm Control Panel. The full user manual and other manuals are available on Alarm Control Panel Firmware Version 1.09 QUICK USER MANUAL The full user manual and other manuals are available on www.satel.eu versa_ip_us_en 11/17 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND

More information

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.

More information

Summit 3208GLD USER MANUAL. Electronics Line

Summit 3208GLD USER MANUAL. Electronics Line Summit 3208GLD USER MANUAL Electronics Line Table of Contents 1: Introduction... 2 2: Overview... 3 3: Keypad Functions... 4 3.1: Keypads... 4 3.2: 3108 LCD Keypad Layout... 4 4: Basic System Operation...

More information

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher IMPORTANT WARNING:This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be

More information

All-In-One Wireless Security System V1.0. Model # MG Programming Guide

All-In-One Wireless Security System V1.0. Model # MG Programming Guide All-In-One Wireless Security System V1.0 Model # MG-6060 Programming Guide Things You Should Know... 4 About This Programming Guide... 4 Conventions... 4 Installer Code (Default: 0000 / 000000)... 4 Maintenance

More information

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY. SK642 WIRELESS WATER ALARM SYSTEM WITH AUTO DIALER OWNER'S MANUAL AND SET UP INSTRUCTIONS. Thank you for choosing Ideal Security s Wireless Water Alarm with Telephone Dialer. Please read through complete

More information

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030 All-In-One Wireless Security System V1.3 Programming Guide Model # MG-6060 / MG-6030 Table of Contents Things You Should Know... 2 About This Programming Guide... 2 Conventions... 2 Installer Code (Default:

More information

(31/03/05) Version p1. INNER RANGE IQ. Programmer s Manual. Programmer s Manual Inner Range Pty. Ltd. Part Number:

(31/03/05) Version p1. INNER RANGE IQ. Programmer s Manual. Programmer s Manual Inner Range Pty. Ltd. Part Number: (31/03/05) Version 2.604 p1 Programmer s Manual 2005. Inner Range Pty. Ltd. Part Number: 630047 p2 Version 2.604 (31/03/05) TABLE OF CONTENTS. Programming Methods... 3 1. Introduction 1.1 System Overview...

More information

ELT-KLED EliteSuite LED Keypad Installation Manual

ELT-KLED EliteSuite LED Keypad Installation Manual ELT-KLED EliteSuite LED Keypad Installation Manual ELT-KLED EliteSuite Installation Manual PUBLICATION INFORMATION First Publication Draft Document Release Only Updated fire zone information Second Publication

More information

AXI LED USER MANUAL (REV. 1.0)

AXI LED USER MANUAL (REV. 1.0) Security & Home Automation System AXI LED USER MANUAL (REV. 1.0) CONTENTS PREFACE FEATURES LED KEYPAD OUTLOOK 1.0 LIGHT INDICATION 1 2 4 6 CHAPTER 1: ALARM SYSTEM CONTROL 1.0 USING LED KEYPAD 1.0.1 ARMING

More information

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual All-In-One Wireless Security System V1.0 Model #: MG-6060 Reference and Installation Manual Table of Contents Introduction... 3 About Magellan and this Manual... 3 Conventions... 3 Specifications... 3

More information

X64 Wireless Training

X64 Wireless Training X64 Wireless Training IDS Contents 1 Contents Features 3 Wireless Hardware 4 IDS & Duevi integration PCB 5 LED operation 5 Wireless Device Hardware setup 6 Location 260 7 LED Keypad Instructions 7 Adding

More information

0$(6752 0$(6752. Programming Guide. 6 and 10 Zone Alarm Control Panel ,1752'8&7,21 +(;$ 352*5$00,1* 675($0/,1(' 6(&7,21 352*5$00,1* FIGURE 1 FIGURE 2

0$(6752 0$(6752. Programming Guide. 6 and 10 Zone Alarm Control Panel ,1752'8&7,21 +(;$ 352*5$00,1* 675($0/,1(' 6(&7,21 352*5$00,1* FIGURE 1 FIGURE 2 0$(6752 0$(6752 6 and 10 Zone Alarm Control Panel Programming Guide,1752'8&7,21 The Maestro-600 and Maestro-1000 alarm control panels enable reduced number of programming steps. End-users can access most

More information

Installation Manual Premier 412/816/832. Issue 10

Installation Manual Premier 412/816/832. Issue 10 Installation Manual Premier // Issue 0 Premier // Installation Manual 5. Operating the System Introduction Before attempting to operate the alarm system ensure you have familiarised yourself with all the

More information

MG5000 MG5050 SP5500 SP6000 SP7000. User Guide

MG5000 MG5050 SP5500 SP6000 SP7000. User Guide MG5000 MG5050 SP5500 SP6000 SP7000 User Guide We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us your comments.

More information

Training Manual Multi-Language with Wireless

Training Manual Multi-Language with Wireless Training Manual Multi-Language with Wireless Installer Training Firmware Version 2.3 X16 Stock Code: 860-1-473-X16 X64 Stock Code: 860-1-864-XS 2 Contents IDS X Series Training V2.3 Contents Contents 3

More information

Elite Version. 8 Zone Control Communicator. Installation & Programming Guide. Proudly Designed and Manufactured in New Zealand

Elite Version. 8 Zone Control Communicator. Installation & Programming Guide. Proudly Designed and Manufactured in New Zealand Elite Version 8D 8 Zone Control Communicator Installation & Programming Guide Proudly Designed and Manufactured in New Zealand This Elite Version 8D alarm control panel has been designed to provide the

More information

ITI Caretaker Basic Commands

ITI Caretaker Basic Commands ITI Caretaker Basic Commands System can be accessed by telephone or wireless keypad Zones - Up to 30 Wireless or 24 Hardwired Battery - 12 volt 1.9 amp rechargeable Lead-Acid inside main panel, only found

More information

All-In-One Wireless Security System V1.0. Model #: MG-6060

All-In-One Wireless Security System V1.0. Model #: MG-6060 All-In-One Wireless Security System V1.0 Model #: MG-6060 Reference and Installation Manual DRAFT Table of Contents Introduction... 5 About Magellan and this Manual... 5 Conventions... 5 Specifications...

More information

Solution 862 Installation Manual ISSUE 1.30

Solution 862 Installation Manual ISSUE 1.30 Solution 862 Installation Manual ISSUE 1.30 MA406I This page has been included for you to cut out and insert into the spine of the folder Solution 862 Installation Manual ISSUE 1.30 (61-2) 9672 1233 Solution

More information

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions WIC-16Z4P WIC-5Z2P User Instructions Page : 2/14 INDEX # Function Page 1 Add a New User Code 11 2 Arm or Disarm All Areas or Disarm Selected Areas (Partitioned System) 8 3 Arming the System (Away Mode)

More information

ICP-CC408 ICP-CC408 EN. Control Panel. User s Guide

ICP-CC408 ICP-CC408 EN. Control Panel. User s Guide ICP-CC408 EN User s Guide ICP-CC408 Control Panel ICP-CC408 User's Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems, Inc, ( Bosch

More information

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 XL-2G Gold Product Overview 7 Zones (6 programmable + panic or keyswitch zone) Fast Loop Response

More information

User s Information Guide R2A

User s Information Guide R2A Pi HSC505 Home Security Controller User s Information Guide R2A Page 1 of 15 of its development program. 1This document and product are copyrighted and all rights are reserved. Introduction Convention

More information

LCD and 16-Zone LED Keypads. User s Manual

LCD and 16-Zone LED Keypads.   User s Manual LCD and 16-Zone LED Keypads 1689 1641 16-Zone LED Keypad LCD Keypad User s Manual TABLE OF CONTENTS 1.0 INTRODUCTION...3 2.0 BASIC OPERATION...4 2.1 Keypad Indicator Lights... 4 2.2 Visual Feedback...

More information

Version 1.03 January-2002 USER S MANUAL

Version 1.03 January-2002 USER S MANUAL Version 1.03 January-2002 1 USER S MANUAL 2 Version 1.03 January-2002 System Details CUSTOMER:...... PHONE:... FAX:... INSTALLED BY:...... PHONE:... FAX:... MAINTENANCE & SERVICE:...... PHONE:... FAX:...

More information

(Updated Defaults) (Covers Ver: 8.64 and above)

(Updated Defaults) (Covers Ver: 8.64 and above) Power Wave - 8 8 Zone Alarm Panel V8.71 / 8.72 (Updated Defaults) (Covers Ver: 8.64 and above) Installation Manual 10-December-2003 Crow (Aust) Electronic Engineering Pty Ltd Corporate Head Office: 429

More information

16 ( Ver: Installation & Programming Guide. Power Wave 16 Zone Control Communicator. Crow Electronic Engineering (Australia) Pty Ltd

16 ( Ver: Installation & Programming Guide. Power Wave 16 Zone Control Communicator. Crow Electronic Engineering (Australia) Pty Ltd Power Wave 16 Zone Control Communicator 16 ( Ver: 6.28 ) This Manual is Preliminary. Please refer to the Condensed manual for additional information Crow Electronic Engineering (Australia) Pty Ltd Installation

More information

Watchguard WGAP864 User Manual

Watchguard WGAP864 User Manual Watchguard WGAP864 User Manual v1.0 Issued September 2016 1 2 Table of Contents Glossary... 5 1. Introduction to your Watchguard WGAP864... 6 2. Before Operating your Alarm System... 6 3. Understanding

More information

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. SK618 WIRELESS ALARM SYSTEM WITH AUTO DIALER OWNER'S MANUAL Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. If at any time during your installation you have any questions

More information

XT30/XT50 PROGRAMMING PART 2. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 2. Bell Options

XT30/XT50 PROGRAMMING PART 2. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 2. Bell Options Slide 1 XT30/XT50 Basic Training Programming- Part 2 Slide 2 Objectives After completing this course you will: 1) Understand how to prepare the panel for programming and how to access the built-in programmer.

More information

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: -961112-0002 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3

More information

Solution 844 Operators Manual ISSUE 1.10

Solution 844 Operators Manual ISSUE 1.10 Solution 844 Operators Manual ISSUE 1.10 Solution 844 Operators Manual Copyright 2001 by, SYDNEY, AUSTRALIA Document Part Number MA406O DOCUMENT ISSUE 1.10 Printed 24 April 2001 This documentation is provided

More information

NetworX Series NX-4V2 Control Panel Installation and Startup

NetworX Series NX-4V2 Control Panel Installation and Startup NetworX Series NX-4V2 Control Panel Installation and Startup 2005 GE Security All rights reserved. These instructions do not purport to cover all details or variations in equipment nor to provide every

More information

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00 INHEP DIGITAL IDS S E C U R I T Y IDS816 User Manual MANUAL NO. 700-283-01 B ISSUED DEC 2004 VERSION 2.00 Contents 1. Introduction to the IDS816... 4 2. Understanding the Keypad Indicators... 4 3. Programmable

More information

DYGIZONE GJD910 Lighting Controller & Enunciator

DYGIZONE GJD910 Lighting Controller & Enunciator DYGIZONE GJD910 Lighting Controller & Enunciator MASTER WIRING IDENTIFICATION Power up to the DygiZone and you will see: All the LED s (red,yellow,green and blue buttons) will flash All the LCD icons will

More information

Property of Monitronics Inc

Property of Monitronics Inc Enter Program Press CODE key + * + 2468 + 1 (also try 2121) Installer Options Move to location Program location Exit Program Default Panel Hex Program Code + * + Installer Code + 1 = Enter Programming

More information

IDS816 User Manual H Issued January 2009

IDS816 User Manual H Issued January 2009 1 Contents Glossary-------------------------------------------------------------------------------------------------------------------6 1. Introduction to the IDS 816---------------------------------------------------------------------------7

More information

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. TABLE OF CONTENTS... P.1 2. GENERAL DESCRIPTION... P.2... 3. STANDARD AND OPTIONAL PARTS LIST... P.2... 4. FEATURE

More information

INSTALLATION MANUAL PC56O. Version 1.OA

INSTALLATION MANUAL PC56O. Version 1.OA INSTALLATION MANUAL PC56O Version 1.OA TABLE OF CONTENTS INTRODUCTION 3 Features... 3 Specifications... 3 INSTALLATION 4 Mounting the Control Panel... 4 Mounting the Keypad... 4 Wiring... 5 Burglary Zone

More information

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00 INHEP DIGITAL IDS S E C U R I T Y IDS816 User Manual MANUAL NO. 700-283-01C ISSUED APRIL 2005 VERSION 2.00 Contents 1. Introduction to the IDS816... 4 2. Understanding the Keypad Indicators... 4 3. Programmable

More information

GEM-P800. Control Panel/Communicator. Installation Instructions

GEM-P800. Control Panel/Communicator. Installation Instructions GEM-P800 Control Panel/Communicator Installation Instructions NAPCO 2002 WI850C 9/02 WI850C GEM-P800 Installation Instructions Table of Contents General Information GEM-P800 Features General Information...

More information

SMS8 Alarm Control Panel

SMS8 Alarm Control Panel SMS8 Alarm Control Panel 8 Zone Alarm Control Panel with LCD Keypad, Inbuilt Dialler for Back to Base Monitoring and SMS Messaging. Easy Operation Dialler SMS Messaging I n s t r u c t i o n s N517 Code

More information

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand 5 Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd Operating Guide Proudly Designed and Manufactured in New Zealand About your Alarm Controller Thank you for choosing to protect your premises

More information

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel DS3MX-E-I EN Installation Guide 3 Mini Control Panel DS3MX-E-I Installation Guide 1.0 General Information EN 2 1.0 General Information The DS3MX is a three zone mini control panel, which can be installed

More information

10-Zone Spectra LED Keypads

10-Zone Spectra LED Keypads 10-Zone Spectra LED Keypads User s Guide TABLE OF CONTENTS Introduction... 5 Basic Operation... 6 Auditory Feedback... 6 Keypad Indicator Lights... 8 Zone Display... 8 Alarm Memory Display... 8 Trouble

More information

Installation & Programming Guide

Installation & Programming Guide S series (8/16 Zone Control Communicator) Installation & Programming Guide Proudly Designed and Manufactured in New Zealand (NZS:4301/93) Security Merchants Australia P/L VIC 03 9558 8455 NSW 02 9890 5300

More information