Fire Hose Brass Adapters, Couplings & Reducers

Size: px
Start display at page:

Download "Fire Hose Brass Adapters, Couplings & Reducers"

Transcription

1 Fire Hose Brass Adapters, Couplings & Reducers BRASS ADAPTERS 2 F M BRASS HEX SWIVEL ADAPTER 57 1½" npt (f) nst (m) Adapter 59 1½" nst (f) npsh (m) Adapter 60 2½" npt (f) nst (m) Adapter 61 2½" nst (f) npt (m) Adapter 53 2½" nst (f) npt (m) Hex Swivel Adapter 3 F F BRASS HEX ADAPTERS 50 1½" npt (f) nst (f) Hex Adapter 51 2½" npt (f) nst (f) Hex Adapter 4 M M BRASS HEX ADAPTER Part# 54 1½" npt (m) 1½" npsh (m) Hex Adapter 55 1½" npt (m) 1½" nst (m) Hex Adapter 56 2½" npt (m) nst (m) Hex Adapter GATE VALVES WITH SWIVEL Speed Handle is Standard Non-Rising Stem Straight Pattern 344S 2½" nst (f) 2½" nst (m) Gate Valve w/ Swivel IE27SH Gate Valve Speed Handle 18 Call today! 5 F F BRASS SWIVEL ADAPTER 58S 2½" npt (f) nst (f) Swivel Adapter 6 F M BRASS REDUCERS 36 2½" nst (f) 1½" nst (m) Reducer 37 2½" npsh (f) 1½" nst (m) Reducer 38 2½" nst (f) 1½" npsh (m) Reducer 39 2½" nst (f) ¾" ght (m) Reducer 41 2½" nyfd (f) 1½" nyfd (m) Reducer 42 2½" nyfd (f) 1½" npsh (m) Reducer CSA, QST, BC, AMA, NFLD, NS-WCT

2 Brass Valves & Inlets ANGLE HOSE VALVES PRESSURE REDUCING BRASS VALVES 114A 1½" npt (f) npt (f) Angle Valve 314A 1½" npt (f) nst (m) Angle Valve 414A 2½" npt (f) nst (m) Angle Valve 514A 1½" npt (f) npsh (m) Angle Valve 15HW Handwheel for 1½" Valve 25HW Handwheel for 2½" Valve 114P 1½" npt (f) npt (f) Pressure Reducing Angle Valve 314P 1½" npt (f) nst (m) Pressure Reducing Angle Valve 214P 2½" npt (f) nst (m) Pressure Reducing Angle Valve GATED WYE CONNECTION 116NST 2½" nst (f) Swivel 1½" nst (m) Gated Wye Connection CSA, QST, BC, AMA, NFLD, NS-WCT STRAIGHT SINGLE CLAPPER SIAMESE INLET 216S 4" npt 2½" 2½" Straight Single Clapper Siamese Inlet 90 SINGLE CLAPPER SIAMESE INLET 226S 4" npt 2½" 2½" 90 Single Clapper Siamese Inlet 3 WAY 1/4" BALL VALVE METAL ANGLE VALVE ENCLOSURE Complete with Door & Trim Corrosion-Resistantt Reinforced Piano Hinge Corbin Latch Locking Designed for Appearance and Efficiency Heavy Duty 16 Gauge Metal 14" 14" 40V 3 Way 1/4" Ball Valve L W D 1414VC Metal Angle Valve Enclosure 14" 14" 8" Charge It! Phone: Fax:

3 Brass Inlets, Wall Escutcheons & Drip Valve STRAIGHT CONCEALED DOUBLE CLAPPER SIAMESE INLET Grooved Fitting grooved fitting 90 CONCEALED DOUBLE CLAPPER SIAMESE INLET Grooved Fitting 146D 4" npt 2½" 2½" Straight Concealed Double Clapper Siamese Inlet POLISHED BRASS RECTANGULAR ESCUTCHEONS 416S 4" npt 2½" 2½" 90 Double Clapper Siamese Inlet WALL ESCUTCHEONS 218S 418A 766A Polished Brass Escutcheon, Auto Sprinkler 766S Polished Brass Escutcheon, Standpipe 766AC Chrome Escutcheon, Auto Sprinkler 766SC Chrome Escutcheon, Standpipe 218A 2½" Round Wall Escutcheon, Auto Sprinkler 218S 2½" Round Wall Escutcheon, Standpipe 418A 4" Round Wall Escutcheon, Auto Sprinkler 418S 4" Round Wall Escutcheon, Standpipe SINGLE INLET CONNECTION FOR RESIDENTIAL SPRINKLER SYSTEMS 586 1½" npt nst Single Inlet Connection for Residential Sprinkler Systems AUTOMATIC STRAIGHT BALL DRIP VALVE 174D ½" npt Automatic Straight Ball Drip Valve 20 Call today!

4 Caps, Couplings, Plugs & Wrenches WRENCHES 28 Trinal Wrench, Combo 1½" 2½" 31 Hydrant Spanner Wrench, 2½" Adjustable BRASS COUPLING SETS HCNST HCNPSH UTG UT SHG BREAK CAPS Choose Aluminum or Plastic BC25A BC25P BC25D 2½" Aluminum Break Cap w/ Eye Bolts 2½" Plastic Break Cap w/ Eye Bolts Adjustable Plastic Break Cap BC25A BC25P BC25D 1½" nst Brass Coupling Set 1½" npsh Brass Coupling Set Tail Gasket for Coupling Expansion Ring for Coupling Swivel Gasket We offer custom imprinted labels, tag seals & engraved signs at exceptional prices. See pages 43, 138, and 139, or call your sales manager today for more info! BP15NST BC15NST BRASS CAPS & PLUGS W/ CHAIN Polished Brass at No Extra Cost BC15NST 1½" nst Brass Cap w/ Chain BC15NPSH 1½" npsh Brass Cap w/ Chain BC25NST 2½" nst Brass Cap w/ Chain BC25NPSH 2½" npsh Brass Cap w/ Chain BP15NST 1½" nst Brass Plug w/ Chain BP15NPSH 1½" npsh Brass Plug w/ Chain BP25NST 2½" nst Brass Plug w/ Chain CSA, QST, WCT, BC, AMA, NS, NFLD Charge It! PLASTIC CAPS W/ CHAIN PC15NST PC15IPT PC25NST PC25NYFD PC25NYC PC25U 1½" nst Plastic Cap w/ Chain 1½" ipt Plastic Cap w/ Chain 2½" nst Plastic Cap w/ Chain 2½" nyfd Plastic Cap w/ Chain 2½" nyc Plastic Cap w/ Chain 2½" Universal Plastic Cap w/ Chain Phone: Fax:

5 Rack & Reel Hose & Accessories RACK & REEL HOSE 500 PSI Acceptance Minimum 250 PSI Service Test Minimum Totally Resistant to Rot or Mildew Competitively Priced All Hose 1½ Inches For Emergency Use Only Rack Hose Not Recommended for Wash-Down Use We bag our hoses to keep them clean. 50NST 75NST 100NST 50NPSH 75NPSH 100NPSH 50' Rack & Reel Hose, 15 Pins, Coupled nst 75' Rack & Reel Hose, 19 Pins, Coupled nst 100' Rack & Reel Hose, 24 Pins, Coupled nst 50' Rack & Reel Hose, 15 Pins, Coupled npsh 75' Rack & Reel Hose, 19 Pins, Coupled npsh 100' Rack & Reel Hose, 24 Pins, Coupled npsh 1 HOSE RACK & REEL Hose Reel and Rack Pivot 180 to Store Flush against the Wall Hose Rack UL, ULC Listed & FM Approved # " Hose Storage Reel " Hose Storage Reel ' 100' Hose Rack for 1½" Diameter Hose 1½" Nipple Hole ' 100' Hose Rack for 1½" Diameter Hose 2½" Nipple Hole 3 HOSE, RACK & REEL ACCESSORIES # 1 HH100 Taraton Hose Hanger 2 FHWD Wall Bracket for Hose Rack 3 BN15NST 1½" Brass Fog/Stream/Shutoff Nozzle (nst) 3 BN15NPSH 1½" Brass Fog/Stream/Shutoff Nozzle (npsh) 4 PIN09 Pin for Hose Rack ½" Rack Nipple (nst) ½" Rack Nipple (nst) ½" Rack Nipple (npsh) NST 1½" nst Stream/Fog, Shut Off Nozzle *See page 23 for additional pricing 22 Call today!

6 Fire Hose & Nozzles SJ50NST 1½" 50' sj, Coupled nst SJ75NST 1½" 75' sj, Coupled nst SJ100NST 1½" 100' sj, Coupled nst SJ5025NST 2½" 50' sj, Coupled nst SJ50NPSH 1½" 50' sj, Coupled npsh SJ75NPSH 1½" 75' sj, Coupled npsh SJ100NPSH 1½" 100' sj, Coupled npsh 2½" Hose: AMA, BC, CSA, QST, NFLD, NS-WCT SINGLE JACKET FIRE HOSE Service Test Pressure 250 PSI or 500 PSI Accepted Test Pressure 750 PSI Burst Pressure 100% Polyester Filament Yarn Never Needs Drying Aluminum Couplings Standard; Brass Available DOUBLE JACKET FIRE HOSE Service Test Pressure 400 PSI or 800 PSI Accepted Test Pressure 100% Polyester Yarn Aluminum Couplings Standard; Brass Available Encap Treatment Available for Additional Heat & Abrasion Resistance DJ50NST 1½" 50' dj, Coupled nst DJ75NST 1½" 75' dj, Coupled nst DJ100NST 1½" 100' dj, Coupled nst DJ5025NST 2½" 50' dj, Coupled nst DJ50NPSH 1½" 50' dj, Coupled npsh DJ75NPSH 1½" 75' dj, Coupled npsh DJ100NPSH 1½" 100' dj, Coupled npsh 2½" Hose: AMA, BC, CSA, QST, NFLD, NS-WCT FIRE HOSE INSPECTION & TEST TAG Provides Columns for Testing and Inspection Records Don t Pass Up $$$; Test Fire Hose and Couplings Actual Tag Size 6¾" 3¼" HOSTAG Fire Hose Inspection & Test Tag POLYCARBONATE FIRE HOSE NOZZLES UL Listed & FM Approved Made with the Very Best High Tech Materials Handles on the 2520 nozzle greatly reduce fatigue from reverse thrust # NST 1½" nst Stream/Fog, Shut Off Nozzle IPT 1½" ipt Stream/Fog, Shut Off Nozzle ENST 1½" nst 30 Fog Only Electric Nozzle EIPT 1½" ipt 30 Fog Only Electric Nozzle n/s 1575NSTGAS 1½" Gasket for 1575NST NST 1" nst Adjustable Fog/Stream Shut Off Nozzle IPT 1" ipt Adjustable Fog/Stream Shut Off Nozzle NST 2½" nst Adjustable Stream Industrial Shut Off Nozzle w/ Handles NSTNH 2½" nst Adjustable Stream Industrial Shut Off Nozzle w/out Handles NST 1½" nst 10" Straight Stream Nozzle IPT 1½" ipt 10" Straight Stream Nozzle Charge It! Phone: Fax:

7 Sprinklers BRASS & CHROME UPRIGHT UL/ULC Listed FM Approved Standard Response CHROME & WHITE PENDANT UL/ULC Listed FM Approved Quick Response BRASS & CHROME PENDANTS UL/ULC Listed FM Approved Standard Response Brass Pendant 155 F ½" npt Brass Pendant 200 F ½" npt Brass Pendant 286 F ½" npt Chrome Pendant 155 F ½" npt Chrome Pendant 200 F ½" npt Brass Pendant 155 F ¾" npt Brass Pendant 200 F ¾" npt Brass Pendant 286 F ¾" npt Chrome Pendant 155 F ¾" npt Chrome Pendant 200 F ¾" npt Chrome Pendant 286 F ¾" npt Brass Upright 155 F ½" npt Brass Upright 200 F ½" npt Brass Upright 286 F ½" npt Brass Upright 155 F ¾" npt Brass Upright 200 F ¾" npt Brass Upright 286 F ¾" npt Chrome Upright 155 F ¾" npt Chrome Upright 200 F ¾" npt Chrome Upright 286 F ¾" npt BRASS & CHROME HORIZONTAL SIDEWALL UL/ULC Listed FM Approved Standard Response Brass Horiz. Sidewall 155 F ½" npt Chrome Horiz. Sidewall 155 F ½" npt CHROME & WHITE HORIZONTAL SIDEWALL UL/ULC Listed FM Approved Quick Response Chrome Horiz. Sidewall 155 F ½" npt White Horiz. Sidewall 155 F ½" npt Chrome Pendant 155 F ½" npt White Pendant 155 F ½" npt CONCEALED SPRINKLER UL/ULC Listed FM Approved Standard Response HC Concealed Sprinkler 155 F ½" npt Chrome HC Concealed Cover Plate White HC Concealed Cover Plate 24 Call today!

8 Sprinkler Accessories MODEL H RECESSED ESCUTCHEON Available in White or Chrome EPC EPW White Model H Escutcheon EPC Chrome Model H Escutcheon ESCUTCHEON PLATES Chrome Plated EP2 EP1 EP1 ½" Escutcheon Plate 1 piece EP2 ½" Escutcheon Plate 2 piece EP3 ¾" Escutcheon Plate 1 piece SPRINKLER GUARD Available in Red or Chrome Heavy Duty Guard Red Only SGLR Sprinkler Guard Large, Red SGLC Sprinkler Guard Large, Chrome SGHD Sprinkler Guard Heavy Duty, Red SGHD SGLC EMERGENCY SPRINKLER CABINET Heavy Duty Red Painted Steel Available in 6 or 12 Unit Cabinets for Sprinkler Heads ESC Emergency Sprinkler Cabinet, 6-Unit ESC12 Emergency Sprinkler Cabinet, 12-Unit ESC12 ESC SPRINKLER WRENCHES For Automatic Sprinkler Recessed or Open Face Recessed Fits Standard Socket SW1 SW1 Sprinkler Wrench, Open Face SW2 Sprinkler Wrench, Recessed SW2 Charge It! Phone: Fax:

9 Smoke Detectors, Cleaner & Test IONIZATION TYPE PHOTOELECTRIC TYPE SMOKE DETECTORS Features Volt Battery Included * Low Battery Warning Easy Twist Off Mounting Tamper-Proof Connection Single or Multiple Station Capability Up to 24 Units in Line Quick Disconnect Power Connector Test Button Emergency Backup Light Hush Button *10 Year Lithium Battery IONIZATION TYPE 84 Battery Operated Smoke Detector (9 Volt) 85 Battery Operated Smoke Detector with Emergency Light (9V) VAC Smoke Detector VAC Smoke Detector with Battery Backup 88 Battery Operated Smoke Detector (9V) VAC Smoke Detector with Battery Backup Year Lithium Battery Operated Smoke Detector 90 SMOKE DETECTOR CLEANER Cleans Detectors on Site Ozone Friendly Removes Dust, Lint, and other Foreign Matter CANNED TEST SMOKE Simulates Full Range of Actual Fire Conditions Quick & Easy to Use Tests Both Photoelectric and Ionization Detectors Over 100 Tests per Can DUST Smoke Detector Cleaner SMOKE Canned Test Smoke 26 Call today!

10 Smoke and Gas Detectors IONIZATION IONIZATION IONIZATION PHOTO-ELECTRIC IONIZATION SA CO IONIZATION NATURAL GAS DETECTOR PROPANE GAS DETECTOR NG200 LP200 NG200 LP200 IONIZATION SMOKE ALARMS respond earlier to fast flaming fires, ones that devour combustibles extremely fast, spread rapidly, and generate considerable heat with little smoke. P HOTO ELECTRIC SMOKE ALARMS respond earlier to smoldering slow fires that generate large amounts of thick, black smoke with little heat, and may smolder for hours before bursting into flames. F or maximum protection, install both ionization and photo electric type smoke Smoke Detector Type Features of Model # 308 SA CO NG200 LP200 Instant test button No expensive replacement sensor Hard Wired 120 Volt AC Loud 85 db alarm pattern Low back-up battery warning Interconnectable for up to 12 units Battery included * N/A N/A Emergency alarm Easy touch alarm pause silencer Digital LED Display Plug-In 120 Volt AC 10-year limited warranty 5-year limited warranty *10-year life 1. Ionization 2. Photo Electric 3. Carbon Monoxide 4. Combination, CO & Ionization 5. Natural Gas 6. Propane Gas Charge It! Phone: Fax:

11 Carbon Monoxide Detectors, Strobe, & Life Ladder CM57 CM76 CARBON MONOXIDE DETECTORS CM57/CM76 5 Year Warranty UL/ULC Listed Test/Reset Button Peak Level Button Digital Display Of CO Levels Updated Digital Reading Every 15 Seconds 85db Alarm CM05 5 Year Warranty Batteries Included 85db Alarm Test/Reset Button Battery Failure Alarm UL/ULC Listed Table Top or Wall Mount CM05 CM05 Carbon Monoxide Alarm Battery Operated CM57 Carbon Monoxide Alarm Direct Plug, Digital CM76 Carbon Monoxide Alarm Direct Plug w/ Battery Backup, Digital STROBE LIGHT FOR HEARING-IMPAIRED Provides Visual Signal to the Hearing-Impaired 5-Year Limited Warranty Bright 177-Candela Strobe Meets UL 1971, NEMA & ADA Standards 83 Combination Photoelectric & Ionization Smoke Detector 91 Strobe Light 3-Wire connect for Fyrnetics Detectors 92 Strobe Light 2-Wire connect for non-fyrnetics Detectors 93 Combination Smoke & Carbon Monoxide Detector COMBINATION PHOTOELECTRIC & IONIZATION SMOKE DETECTOR Dual Sensor Technology 5-Year Limited Warranty Test Button & LED allow Simple Verification of Battery & Alarm Functions Battery Operated COMBINATION SMOKE & CARBON MONOXIDE DETECTOR Interconnectable 120VAC 9V Battery Backup Differentiates Smoke and CO Signal to Sound the Appropriate Warning Single Button Tests Smoke & CO Sensors LIFE LADDERS Instant Fire Escape Deploys Quickly, Stores Easily Portable and Compact 2 Sizes Available Capacity Up to 1,000 lb 2H 13' Life Ladder 3H 25' Life Ladder 28 Call today!

12 Forestry Pumps, Fire Hose Enclosures & Kits FORESTRY PUMPS #1 Floor/ Backpack Forestry Pump Backpack or Floor Shoulder Mount Rigid Polyethylene Over 2 Gallon Capacity #2 Backpack Forestry Pump Nylon Bladder Very Lightweight Almost 3 Gallon Capacity 1 2 # 1 FHP400 Polyethylene Floor/ Backpack Forestry Pump 2 FHP300 Collapsible/Backpack Forestry Pump OR COMPLETE FIRE HOSE & ENCLOSURE KIT Kit includes: Fire Hose Enclosure Fire Hose: 50', 75' or 100' Rack Nipple Hose Pin Rack 1½" NPT Angle Valve (F) 1½" Hose Nozzle (Brass or Polycarbonate) Hose Length Brass Poly 50' FHKB1 FHKP1 75' FHKB2 FHKP2 100' FHKB3 FHKP3 METAL FIRE HOSE ENCLOSURE Holds Up to 100' 1½" Rack Hose Fitted with 3/16" Clear Glass Pro-Tech Premier Primer 16-Gauge Steel Construction L W D 3030HC Metal Fire Hose Enclosure 30" 30" 8" Charge It! Phone: Fax:

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University. 15500 - FIRE PROTECTION PART I DESIGN GUIDELINES A. General 1. Vertical fire pumps shall not be used at the University. 2. coupling piping shall be permitted for sprinkler and standpipe systems only. B.

More information

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements. FIRE PROTECTION GENERAL INFORMATION 1.1 Refer to Section 230000 for General Mechanical Requirements. 1.2 Refer to Section 230529 for Hangers and Supports. 1.3 Refer to Section 230553 for Pipe and Equipment

More information

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES DIVISION 21 FIRE SUPPRESSION PART 1 GENERAL 1.01 DESCRIPTION A. Provide UL listed, FM approved listed fire protection specialties or accessories as required by either the equipment manufacturer or the

More information

Gas Station & C Store SECTION CWM Job No

Gas Station & C Store SECTION CWM Job No SECTION 21 1300 - PART 1 - GENERAL 1.1 WORK INCLUDED A. Provide labor, materials, equipment and services to perform operations required for the complete installation and related Work as required in Contract

More information

B. Related Sections: The following Sections contain requirements that relate to this Section.

B. Related Sections: The following Sections contain requirements that relate to this Section. SECTION 211313- FIRE-SUPPRESSION PIPING PART1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general prov1s1ons of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM SECTION 21 0000 AUTOMATIC FIRE SPRINKLER SYSTEM PART 1 GENERAL 1.1 QUALITY ASSURANCE A. Codes and Standards: 1. FBC (Florida Building Code 2015) 2. FBC (Florida Fire Code 2015) 3. NFPA #13R (Standard for

More information

SECTION DRY-PIPE SPRINKLER SYSTEMS

SECTION DRY-PIPE SPRINKLER SYSTEMS SECTION 21 1300 S PART 1 -GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION SECTION 21 1301- FIRE-SUPPRESSION SYSTEMS PART 1 - GENERAL 1.1 SUMMARY: A. This Section includes fire-suppression piping and equipment for the following building systems: 1. Wet-pipe, fire-suppression

More information

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

A. Section includes wet-pipe sprinkler system, system design, installation, and certification. SECTION 21 13 13 WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes wet-pipe sprinkler system, system design, installation, and certification. 1.2 REFERENCES A. General: Comply

More information

Fire Safety and Whole Home Protection

Fire Safety and Whole Home Protection PRODUCT CATALOGUE Distribution Partner Fire Safety and Whole Home Protection SMOKE AND FIRE FACTS CHOOSING THE RIGHT ALARM First Alert, one of the most recognized safety brands in Canada, offers an array

More information

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following: SECTION 21 10 00 - WATER-BASED FIRE-SUPPRESSION PART I - GENERAL 1.1 SUMMARY A. Inclusion of sprinkler and standpipe systems shall be as determined by NFPA National Fire Code pamphlet 101 and program statement.

More information

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE SECTION 21 1316 DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE PART 1 GENERAL 1.01 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department

More information

SECTION SPRINKLER SYSTEMS

SECTION SPRINKLER SYSTEMS SECTION 15325 SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Wet-pipe sprinkler systems. B. Preaction sprinkler systems. C. System design, installation, and certification. D. Fire department

More information

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE SECTION 21 1313 WET-PIPE SPRINKLER SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Wet-pipe sprinkler system. B. System design, installation, and certification. C. Fire department connections. 1.02 RELATED

More information

SECTION FIRE PROTECTION

SECTION FIRE PROTECTION SECTION 15300 - FIRE PROTECTION PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR

More information

Environmental Health & Safety

Environmental Health & Safety Environmental Health & Safety Oklahoma State University FIRE SPRINKLER SYSTEM STANDARD Environmental Health and Safety University Health Services Suite 002 Stillwater, OK 74078 (405) 744-7241 www.ehs.okstate.edu

More information

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES SECTION 15300 FIRE PROTECTION PART 1 DESIGN DIRECTIVES 1.1 DESIGN CRITERIA A. Dartmouth College is currently insured by Factory Mutual. References to the owner s insurance company in this specification

More information

B. Section Identification for Fire Suppression Piping and Equipment.

B. Section Identification for Fire Suppression Piping and Equipment. SECTION 211300 - FIRE SUPPRESSION SPRINKLERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department connections. 1.2 RELATED

More information

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8 City of Ottawa Project No. CR006230 Page 1 of 8 PART 1 - GENERAL 1.1 Reference Standards.1 Conform to the following:.1 Provincial and municipal building and fire regulations as approved by Provincial Fire

More information

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section PART 1 - GENERAL 1.00 GENERAL PROVISIONS A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section 1.01 DESCRIPTION OF WORK A. Work Included: Provide

More information

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings. DIVISION 21 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, sleeves, escutcheons, seals, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS

More information

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE SECTION 21 1316 DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE PART 1 GENERAL 1.01 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department

More information

SECTION SPRINKLER SYSTEMS

SECTION SPRINKLER SYSTEMS SECTION 13900 SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

CO ALARMS GAS DETECTION HYDRANT BOOSTERS MOUNTS PUMP SOLUTIONS SUPPRESSION SYSTEMS. /fireprotection

CO ALARMS GAS DETECTION HYDRANT BOOSTERS MOUNTS PUMP SOLUTIONS SUPPRESSION SYSTEMS. /fireprotection FIRE PROTECTION CO ALARMS GAS DETECTION HYDRANT BOOSTERS MOUNTS SPRINKLER PUMP SOLUTIONS SUPPRESSION SYSTEMS Shop /fireprotection 1.800.323.0244 EDARLEY.COM/FIREPROTECTION FIRE PROTECTION HALOTRON I CLEAN

More information

Used Fluid Handling Portable Used Oil Gravity Drains

Used Fluid Handling Portable Used Oil Gravity Drains Portable Used Oil Gravity Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s)

More information

Model F1 LO K 8.0 (115 metric) Standard Response Sprinklers

Model F1 LO K 8.0 (115 metric) Standard Response Sprinklers Model F1 LO K 8.0 (115 metric) Standard Response s Bulletin 117 Rev. Z Bulletin 117 Rev. Z Model F1 LO Standard Spray Upright Standard Spray Pendent Extended Coverage Pendent Conventional Model F1 LO Recessed

More information

SECTION FIRE-SUPPRESSION STANDPIPES

SECTION FIRE-SUPPRESSION STANDPIPES PART 1 - GENERAL 1.1 DESCRIPTION Fire-suppression wet and manual dry standpipes. 1.2 SCOPE OF WORK SECTION 21 12 00 A. Design, installation and testing shall be in accordance with NFPA 14 except for specified

More information

HALOTRON I CLEAN AGENT FOR A, B & C FIRES REGULAR B:C FIRE EXTINGUISHERS PURPLE K B:C POTASSIUM BICARBONATE EXTINGUISHERS

HALOTRON I CLEAN AGENT FOR A, B & C FIRES REGULAR B:C FIRE EXTINGUISHERS PURPLE K B:C POTASSIUM BICARBONATE EXTINGUISHERS HALOTRON I CLEAN AGENT FOR A, B & C FIRES Halotron I clean fire extinguishing agent discharges as a rapidly evaporating liquid, which is non-conductive, non-corrosive, and leaves behind no residue. Determined

More information

Purple K B:C Potassium Bicarbonate Extinguishers

Purple K B:C Potassium Bicarbonate Extinguishers Halotron I Clean Agent For A, B & C Fires Halotron I clean fire extinguishing agent discharges as a rapidly evaporating liquid, which is non-conductive, non-corrosive, and leaves behind no residue. Determined

More information

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant. SECTION 218800 - FIRE PROTECTION 1. GENERAL A. Provisions of Division 1, GENERAL REQUIREMENTS, and Section 230000, MECHANICAL GENERAL CONDITIONS, and Section 230050, SEISMIC PROTECTION are a part of this

More information

UBC Technical Guidelines Section Edition Fire Protection General Requirements Page 1 of 6

UBC Technical Guidelines Section Edition Fire Protection General Requirements Page 1 of 6 Page 1 of 6 1.0 GENERAL 1.1 Related UBC Guidelines.1 Section 20 00 05 Mechanical - General Requirements.2 Section 22 05 00 Plumbing - General Requirements.3 UBC Standard Fire Hydrant Drawings.4 Section

More information

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS SECTION 15501 WET AUTOMATIC FIRE SPRINKLER SYSTEMS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Wet automatic fire sprinkler systems including fire pump, fire pump controller, alarms, safety devices,

More information

Objective 1: Describe fire alarm systems.

Objective 1: Describe fire alarm systems. Chapter 20 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Describe fire alarm systems. 1. The purpose of a fire alarm system is to: (1178) A. prevent

More information

SECTION WET FIRE SPRINKLER SYSTEMS

SECTION WET FIRE SPRINKLER SYSTEMS SUNY GENESEO 211310-1 PART 1 - GENERAL 1.1 WORK INCLUDED A. Provide labor, materials, equipment and services to perform operations required for the complete installation and related Work as required in

More information

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA August 14, 2013 Sprinkler 126k 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Flush Horizontal Sidewall Sprinklers are small, flush, solder link and lever sprinklers made with tamper-resistant

More information

A. This section includes design and performance information for fire protection and suppression systems.

A. This section includes design and performance information for fire protection and suppression systems. SECTION 21 00 10: FIRE PROTECTION SYSTEM DESIGN 1. SUMMARY A. This section includes design and performance information for fire protection and suppression systems. 2. GENERAL A. All fire protection materials

More information

SMOKE & CARBON MONOXIDE ALARMS

SMOKE & CARBON MONOXIDE ALARMS SMOKE & CARBON MONOXIDE ALARMS COMBINATION SMOKE & CARBON MONOXIDE ALARMS SMOKE ALARMS CARBON MONOXIDE ALARMS Partners in Safety with Kidde... WORRY-FREE 10 YEAR SEALED-IN BATTERY FAST Parts Division of

More information

B. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements.

B. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements. SECTION 21 13 13 FIRE PROTECTION SPRINKLER SYSTEMS PART 1 - GENERAL 1.01 SUMMARY A. Section includes labor and materials for the installation of a hydraulically calculated automatic, wet-pipe sprinkler

More information

Extinguisher Chemical Refill

Extinguisher Chemical Refill Halotron I Clean Agent For A, B & C Fires The most broadly tested and approved 1211 replacement product available that s safe, environmentally friendly, effective and easy-to-use! Halotron is a clean fire

More information

SUPPORT EQUIPMENT MODULAR RAPIDLY DEPLOYABLE MOBILE RUGGED RELIABLE VERSATILE

SUPPORT EQUIPMENT MODULAR RAPIDLY DEPLOYABLE MOBILE RUGGED RELIABLE VERSATILE SUPPORT EQUIPMENT MODULAR RAPIDLY DEPLOYABLE MOBILE RUGGED RELIABLE VERSATILE SUPPORT EQUIPMENT Deployable Rapid Assembly Shelter (DRASH) Support Equipment are shelter components that can be used to enhance

More information

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM SECTION 213100 WET PIPE FIRE PROTECTION SPRINKLER SYSTEM PART 1 - GENERAL 1.01 GENERAL REQUIREMENTS A. The requirements of the General Conditions and Supplementary Conditions apply to all work herein.

More information

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL SECTION 21 13 16 DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

Frequently Asked Smoke Alarm Questions

Frequently Asked Smoke Alarm Questions Frequently Asked Smoke Alarm Questions Why should my home have smoke alarms? Most fire deaths are caused by smoke not flames. Most fire deaths and injuries occur between midnight and 8 a.m. when people

More information

Extinguishers. ABC Dry Chemical Fire Extinguisher. Carbon Dioxide Fire Extinguisher. Halotron Fire Extinguisher

Extinguishers. ABC Dry Chemical Fire Extinguisher. Carbon Dioxide Fire Extinguisher. Halotron Fire Extinguisher Extinguishers ABC Dry Chemical Fire Extinguisher ABC or multi-purpose extinguishers utilize a specially fluidized siliconized mono ammonium phosphate dry chemical, it chemically insulates Class A fires

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE October 10, 2008 Deluge Devices 281a 1. PRODUCT DESCRIPTION The Viking Model C-1 is a rate-of-rise releasing device for use on hydraulic and pneumatic release systems controlling operation of Viking deluge

More information

Smoke & Carbon Monoxide Alarms

Smoke & Carbon Monoxide Alarms Smoke & Carbon Monoxide Alarms Combination Smoke and Carbon Monoxide Alarms Smoke Alarms Carbon Monoxide Alarms Partners in Safety with Kidde... Worry-Free 10 Year Sealed-In Battery page 2 Kidde Product

More information

PART 1 - GENERAL SECTION FIRE PROTECTION BASIC MATERIALS AND METHODS

PART 1 - GENERAL SECTION FIRE PROTECTION BASIC MATERIALS AND METHODS FIRE PROTECTION BA SECTION 13910 - FIRE PROTECTION BASIC MATERIALS AND METHODS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Pipe, fittings, valves, and connections for sprinkler, standpipe and fire hose,

More information

Model DDX Deluge Valve

Model DDX Deluge Valve Model DDX Deluge Valve Bulletin 510 Bulletin 510 Features 1. Differential type, simple, lightweight, dependable construction. 2. Simply and easily trimmed for releasing by: Manual pull stations Wet pilot

More information

WHY CHOOSE AN EXTREME DUTY MULTI VAC INDUSTRIAL VACUUM SYSTEM?

WHY CHOOSE AN EXTREME DUTY MULTI VAC INDUSTRIAL VACUUM SYSTEM? WHY CHOOSE AN EXTREME DUTY MULTI VAC INDUSTRIAL VACUUM SYSTEM? Meet the most USER FRIENDLY vacuum on the market today. The MULTI-VAC team has produced hundreds of machines over the last twenty years. As

More information

Used Fluid Handling Portable Used-Oil Gravity Drains

Used Fluid Handling Portable Used-Oil Gravity Drains Portable Used-Oil Gravity Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s)

More information

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA Page 1 of 8 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Standard Coverage/Extended Coverage Flush Pendent Sprinklers are small, flush, solder link and lever sprinklers made with tamper-resistant

More information

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA Sprinkler 126k Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Flush Horizontal

More information

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM ANNEXUREIII D: FIRE PROTECTION SYSTEM SECTION ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM Supply, Installation, testing and commissioning of Analogue Addressable Fire Alarm Control panel with battery backup

More information

PriceList Category PartNbr Part Description Weight (l MSRP

PriceList Category PartNbr Part Description Weight (l MSRP Date Printed :4/22/2014 12:04:43 PM Effective 4-MAR-2014 CATALOG PRICING Note:Price amounts shown are in US$ PriceList Category PartNbr Part Description Weight (l MSRP ANSUL Restaurant Systems PIRANHA

More information

TotalPac 3 Firecyle III Deluge Remote controlled system

TotalPac 3 Firecyle III Deluge Remote controlled system (Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a Firecycle III system trim totally preassembled, pre-wired and factory tested. All electrical

More information

National Fire Equipment Ltd.

National Fire Equipment Ltd. National Fire Equipment Ltd. Distributor Special Net Price List - No. 400W - 040115 EFFECTIVE April - 2015 (Replaces July 2nd, 2014) PRICES: PRICES ARE NET. No further discounts apply on all pages. TAXES:

More information

WAL-RICH CORPORATION SINCE 1950

WAL-RICH CORPORATION SINCE 1950 HOSES 3/8 ID DOUBLE FEMALE HOSE - BAGGED BAGGED# SIZE Box 0802002 3/4 FHT x 4' 1 25 0802004 3/4 FHT x 5' 1 25 0802006 3/4 FHT x 6' 1 25 0802008 3/4 FHT x 8' 1 25 0802010 3/4 FHT x 10' 1 25 0802012 3/4

More information

LIFESAVER MODEL SL240 REMOTE VISUAL SIGNALLING DEVICE (STROBE LIGHT)

LIFESAVER MODEL SL240 REMOTE VISUAL SIGNALLING DEVICE (STROBE LIGHT) LIFESAVER MODEL SL240 REMOTE VISUAL SIGNALLING DEVICE (STROBE LIGHT) USER MANUAL AUSTRALIAN ELECTRICAL AUTHORITY CS96313V IMPORTANT! READ ALL INSTRUCTIONS BEFORE INSTALLATION AND LEAVE THIS MANUAL FOR

More information

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked. PHOTOELECTRIC SMOKE AND FIRE ALARM USER S GUIDE MODEL PE120 A.C. Wire-in Single and/or Multiple Station (24 units maximum) Photoelectric Smoke Alarm with 9 Volt Battery Back Up Thank you for purchasing

More information

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler Bulletin 018 Rev. H Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler Bulletin 018 Rev. H Product Description The Reliable Model JL-14 Early Suppression Fast Response

More information

FIRE PROTECTION. /fireprotection FIRE PROTECTION EDARLEY.COM/FIREPROTECTION HALOTRON I CLEAN AGENT FOR A, B & C FIRES

FIRE PROTECTION. /fireprotection FIRE PROTECTION EDARLEY.COM/FIREPROTECTION HALOTRON I CLEAN AGENT FOR A, B & C FIRES FIRE PROTECTION CO ALARMS GAS DETECTION HYDRANT BOOSTERS MOUNTS SPRINKLER PUMP SOLUTIONS SUPPRESSION SYSTEMS Shop /fireprotection HALOTRON I CLEAN AGENT FOR A, B & C FIRES Halotron I clean fire extinguishing

More information

Hose. Propane Hose. 1 X-treme Low Temp Bobtail Hose. Large Transfer Hose. Construction Tube: Cover: Reinforcement: Temp. Range:

Hose. Propane Hose. 1 X-treme Low Temp Bobtail Hose. Large Transfer Hose. Construction Tube: Cover: Reinforcement: Temp. Range: Propane For liquid or gaseous transfer of propane. 350 lb working pressure. All sizes are UL21 and CGA Type 1 approved. Cover is pin pricked for gas dissipation. I.D O.D Spirals Lbs per ft..610.15.760.22

More information

2408/2900. Fire Guard

2408/2900. Fire Guard 2408/2900 Fire Guard Table of Contents Features and Additional Fire Opening Devices... 1 2408 Single-Point Hold Open Applications and Mounting Details... 2 2408 Track Assemblies, Arms and Components...

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 21 1314W - AUTOMATIC SPRINKLER SYSTEMS (WET PIPE SYSTEMS) PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Lubrication Tools and Equipment Portable Oil Drains

Lubrication Tools and Equipment Portable Oil Drains Portable Oil Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s) into a portable

More information

THE THOMPSON MODEL A STEAMER NEW UNIT ASSEMBLY INSTRUCTIONS

THE THOMPSON MODEL A STEAMER NEW UNIT ASSEMBLY INSTRUCTIONS THE THOMPSON MODEL A STEAMER NEW UNIT ASSEMBLY INSTRUCTIONS Included with this unit are 1 propane regulator, 1 propane hose assembly, 1 filler plug wrench and 100' of steam hose. In order to operate this

More information

SPRINKLERS TABLE OF CONTENTS

SPRINKLERS TABLE OF CONTENTS SPRINKLERS TABLE OF CONTENTS SECTION 21 13 13 WET PIPE SPRINKLER SYSTEMS SECTION 211313 - WET PIPE SPRINKLER SYSTEMS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract,

More information

Ultra Boiler Series 1 & 2 Jacket Parts

Ultra Boiler Series 1 & 2 Jacket Parts GAS Ultra Boiler Series 1 & 2 Jacket Parts 9 10 8 6 7 1 5 2 3 Fig. Part Description Model Mfr. 1 383-500-135 Jacket Front Door 595-000-000 595-000-001 595-000-002 595-000-003 Panel Door Jacket Plastic

More information

PROFESSIONAL SUPPLIER

PROFESSIONAL SUPPLIER PROFESSIONAL SUPPLIER FOR FIRE-FIGHTING EQUIPMENT IRON MAN INDUSTRY LIMITED Sprinkler Small orifice, standard and quick response, spray sprinkler Designed for use in light hazard occupancies Requires less

More information

SHOWER, EYEWASH & FACEWASH PRODUCTS

SHOWER, EYEWASH & FACEWASH PRODUCTS EYE/FACEWASH PARTS SERVICE KNOWLEDGE SELF- CONTAINED QUALITY INNOVATION SHOWER, EYEWASH & FACEWASH PRODUCTS PRICELIST 2017 Effective January 1 st, 2017 Issued November 17 th, 2016 LEADERS SOLUTIONS SHOWER

More information

FIRE SUPPRESSION SPRINKLER SYSTEM

FIRE SUPPRESSION SPRINKLER SYSTEM PART 1 GENERAL 1.01 DESCRIPTION A. The provisions of the General Requirements, Supplementary Requirements, and Division 1 apply to the plumbing work specified in this Division. B. The requirements of this

More information

Sprinkler Guards Model C Model D

Sprinkler Guards Model C Model D Bulletin 208 Rev. G Sprinkler Guards Model C Model D Bulletin 208 Rev. G Model C Sprinkler Guards Model C Series sprinkler guards are designed to be assembled onto installed sprinklers. They are constructed

More information

Fire Sprinkler Monitoring Products. Solutions and Service for Sprinkler System Integrity

Fire Sprinkler Monitoring Products. Solutions and Service for Sprinkler System Integrity Fire Sprinkler Monitoring Products Solutions and Service for Sprinkler System Integrity waterflow monitoring Monitoring Fire Sprinkler System Flow During a fire condition, sprinkler system reliability

More information

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved Fire Guard SARGENT Manufacturing Company 2004, 2007 All rights reserved Fire Guard Table of Contents Features and Additional Fire Opening Devices............................1 2408 Single-Point Hold Open

More information

2409/2900. Fire Guard

2409/2900. Fire Guard 2409/2900 Fire Guard Table of Contents Features and Additional Fire Opening Devices... 1 2409 Single-Point Hold Open Applications and Mounting Details... 2 2409 Track Assemblies, Arms and Components...

More information

Capital Projects Group Fire Protection Sprinkler System Specification

Capital Projects Group Fire Protection Sprinkler System Specification Capital Projects Group Fire Protection Sprinkler System Specification Specification 21 13 00 Revision 0 Date: August 2018 Fire Protection Sprinkler System Specification Specification 21 13 00 Publication

More information

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers Bulletin 060 Rev. A Bulletin 060 Rev. A Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers Features 1. Available in the following configurations: Pendent with standard escutcheon

More information

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION WET-PIPE SPRINKLER SYSTEMS SECTION 21 13 13 WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Specialties Quality, Durability, Reliability. FIrE ProTECTIon

Specialties Quality, Durability, Reliability. FIrE ProTECTIon _specialties:pcsectiond_new 2/6/2012 4:46 PM Page -36 36 SECTIon Specialties Quality, Durability, Reliability FIrE ProTECTIon In addition to our plumbing business, LYNCAR has been a leading supplier to

More information

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

Model vkfd28b braided flexible sprinkler drops (lpcb approved) Page 1 of 6 1. DESCRIPTION Viking Flexible Sprinkler Drops are a complete assembly intended for installation into commercial suspended ceilings with medium to heavy support tee bars as described in ASTM

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE January 27, 2012 311a 1. DEsCrIpTIoN (Refer to Figures 1-3.) Viking supervised Single Interlocked Preaction Systems utilize a Viking Deluge Valve and a pneumatically pressurized automatic sprinkler system.

More information

ADDITIONAL PRODUCTS 65

ADDITIONAL PRODUCTS 65 ADDITIONAL PRODUCTS 65 ADDITIONAL PRODUCTS Pictorial Table of Contents Model FastFlex Flexible Sprinkler Hose Page 67 Sprinkler & Valves Product Overview Page 72 Model UFBX Flexible Hoses Pages 68-69 Figure

More information

Hardware. October 20, 2018 Prices and product availability are subject to change without notice. 27" Locking Table Leg System

Hardware. October 20, 2018 Prices and product availability are subject to change without notice. 27 Locking Table Leg System Page 1 of 6 Hardware 27" Locking Table Leg System 29" Locking Table Leg System 25" Sur-Fit Table Leg System 29" Sur-Fit Table Leg System $45.50 (IT-724027) $48.00 (IT-724029) $32.00 (IT-724025) $34.00

More information

ACCESS THE WORLD OF KNOX Product Catalog

ACCESS THE WORLD OF KNOX Product Catalog ACCESS THE WORLD OF KNOX 2018-2019 Product Catalog 2 ABOUT KNOX 40+ Over forty years ago, a unique concept in fire response was born: KnoxBox, a high security lock box was designed to provide rapid entry,

More information

TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG U )

TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG U ) TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG0176866-U ) FIRE PROTECTION EQUIPMENTS PARTS CATALOGUE TRIMAX ASIA ENGINEERING & CONSTRUCTION No. 24, Jalan Pantai, 12000 Butterworth, Penang, Malaysia. Fax: +6

More information

Electric Automatic Carpet Extractor. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

Electric Automatic Carpet Extractor. Operator and Parts Manual. Model No.: Rev. 00 (11-99) 1520 Electric Automatic Carpet Extractor Model No.: 607649 Operator and Parts Manual TENNANT COMPANY Commercial Products 12875 RANSOM STREET HOLLAND MI 49424 U.S.A. FAX: 1 800 678 4240 CUSTOMER SERVICE:

More information

Model F1 Residential Sprinklers for Design Density of.10 gpm/ft 2

Model F1 Residential Sprinklers for Design Density of.10 gpm/ft 2 Model F1 Res s engineered for the lowest flows to meet the minimum design density of.05 gpm/ft 2 Types: 1. F1 Res 49 Pendent 2. F1 Res 49 Recessed Pendent/F1 3. F1 Res 49 Recessed Pendent/FP 4. F1 Res

More information

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists. Replacement parts Replacement parts must be purchased through a local Weil-McLain distributor. When ordering, specify boiler model and size and include description and part of replacement part. Results

More information

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14 SECTION 210523 - GENERAL-DUTY VALVES FOR WATER-BASED FIRE-SUPPRESSION PIPING PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

Checklist For Life Safety

Checklist For Life Safety INSPECTION CHECKLIST Date of Inspection: Location/Address: Weather Condition: Inspector: AFTER COMPLETING YOUR INSPECTION, TRANSFER YOUR CONCERNS/OBSERVATIONS TO THIS AREA Facility: Name: Staff Contact:

More information

TECHNICAL DATA. Wet 26a. February 22, 2009

TECHNICAL DATA. Wet 26a. February 22, 2009 February 22, 2009 Wet 26a 1. DESCRIPTION The Viking Alarm Check Valve serves as a check valve by trapping pressurized water above the clapper and preventing reverse flow from sprinkler piping. The valve

More information

2016 CDM Smith All Rights Reserved July 2016 SECTION FIRE PROTECTION - SPRINKLER AND STANDPIPE SYSTEMS

2016 CDM Smith All Rights Reserved July 2016 SECTION FIRE PROTECTION - SPRINKLER AND STANDPIPE SYSTEMS PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 21 13 13 FIRE PROTECTION - SPRINKLER AND STANDPIPE SYSTEMS A. Furnish all labor, materials, equipment services and incidentals required to design and install properly

More information

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions: SECTION 21 13 13 WET-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

SMOKE/CARBON MONOXIDE DETECTOR REQUIREMENTS

SMOKE/CARBON MONOXIDE DETECTOR REQUIREMENTS HOMES BUILT PRIOR TO JANUARY 1, 1975 WITH NO RENOVATIONS As of December 1, 2016, upon sale or transfer Must be located on every level of the residence Must be located on the ceiling at the base of each

More information

Model F1FR Series Quick Response Standard Spray

Model F1FR Series Quick Response Standard Spray Model F1FR 56 Types Standard Upright Standard Pendent Model F1FR 56 Recessed Types Standard Pendent/F1/F2/FP Model F1FR 56 Concealed Types Standard Pendent Listing & Approvals 1. Underwriters Laboratories

More information

Parts Manual Vermeer/McLaughlin V500LTHD Vacuum Machine Part #E (SERIAL # 5DHDLT _5DHDLT )

Parts Manual Vermeer/McLaughlin V500LTHD Vacuum Machine Part #E (SERIAL # 5DHDLT _5DHDLT ) 006 Perimeter Road. Greenville, SC 9605 Toll Free: 800/5-90 - Phone: 86/77-5870 Fax: 86/5-9661 - Website address: www.mightymole.com Email address: mmole@mightymole.com Parts Manual Vermeer/McLaughlin

More information

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM SECTION 21 10 00 PART 1 - GENERAL 1.1 CODES A. Work shall conform to NFPA 13 Sprinkler Systems, 2002 Edition and NFPA 24 Outside Protection, 2002 Edition. NFPA 14 Standpipe Systems, 2000 Edition and International

More information

smoke alarms carbon monoxide alarms fire extinguishers safety products productcatalog

smoke alarms carbon monoxide alarms fire extinguishers safety products productcatalog smoke alarms carbon monoxide alarms fire extinguishers safety products productcatalog safety RECONSIDERED Are you offering the most advanced line of safety products to your consumers? Today s homeowners

More information

TECHNICAL DATA. model c-2

TECHNICAL DATA. model c-2 Page 1 of 6 1. PRODUCT DESCRIPTION The Viking Model C-2 is a rate-of-rise releasing device for use on hydraulic and pneumatic release systems controlling operation of Viking deluge valves on deluge or

More information

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types: Worldwide Contacts www.tyco-fire.com DV-5 Red-E Cabinet Integrated Preaction Fire Protection Package General Description The TYCO DV-5 Red-E Cabinet is a pre-assembled fire protection valve package enclosed

More information