1 CI/SfB (57.5) climate systems November 2008

2 High-comfort, low-energy ventilation An energy efficient, fresh, clean and healthy climate - all year round Ubbink Heat Recovery Ventilation (HRV) systems provide constant, controlled ventilation to homes without creating cold draughts or increasing the heat loss normally caused by ventilation. By using a Ubbink HRV system the calculated heat loss is actually reduced, making homes much more energy efficient. Stale air - polluted with smells, CO 2 and humidity will be constantly extracted via ducted air valves in the kitchen, utility, bathrooms and cloakrooms and passed through a counter current heat exchanger before being evacuated to the outside as cold air. Fresh air - ducted from outside via a G6 pollen filter, is warmed by the high efficiency heat exchanger and then delivered through air valves into living rooms and bedrooms. All appliances are tested and listed to SAP Appendix Q. A COMPACT APPLIANCE IN 3 VERSIONS The appliance comes in three versions and three capacities at 150Pa: Ubbink HRV Compact C180 - capacity of 180m 3 /h; Ubbink HRV Medio M300 - capacity of 300m 3 /h; Ubbink HRV Grande G400 - capacity of 400m 3 /h. EVERY SITUATION REQUIRES ITS OWN APPLIANCE Ubbink HRV M300 and G400 are available in two versions - with four air connections at the top (4b) as standard or with two connections at the top and two at the bottom (2b/2o) to special order. Ubbink HRV C180 is only available with four air connections at the top (4b). The air output spigots to the atmosphere and the air input from the atmosphere are always at the top. All air connections come with a groove for sealing rings. Dependent on the air flow rate, Ubbink HRV C180 is suitable for connecting ducts of Ø125mm, M300 for ducts of Ø150 or Ø160mm (from approx. 260m 3 /h) and G400 for ducts of Ø180mm. CONSTANT FLOW FANS At the chosen ventilation setting, the constant flow fans keep the air flow rate constant under all conditions. This results in a permanently high efficiency while reducing initial adjustments to the minimum. The air flow rate is not influenced by filter fouling either. FROST PROTECTION The frost protection system provides optimum protection from freezing which preserves the high efficiency of the system at extreme temperatures. Constant filtering The appliances come with two standard filters that can easily be removed. (These filters remove 95% of the dust from the air. A high-performance fine dust filter is optionally available (see bottom filter on the photograph). 2

3 KEY 1. Heated fresh air to living rooms and bedrooms 2. Cold stale air to outside 3. Warm stale air from kitchen, bathrooms and cloakrooms 4. Fresh outside air 5. Filters 6. Heat exchanger 7. Control pcb 8. Settings display 9. Direct current fans (for constant volume) 10. Condensate discharge Settings display All appliances incorporate a settings and functions display for increased ease of installation and operation. An optional cable kit and diagnosis software are available for computer servicing purposes Ubbink HRV M300 4b R illustrated 95% efficient The synthetic heat exchanger transfers 95% of the heat, which makes further heating of the ventilation air superfluous (measured under NEN 5138). Technical specifications Appliance Compact C180 Medio M300 Grande G400 Ventilation capacity at 150Pa [m 3 /h] Maximum 180 Maximum 300 Maximum 400 Rated power [W] (dependent on setting) 120 at 150m 3 /h (at 150 Pa) 175 at 300m 3 /h (at 150Pa) 300 at 400m 3 /h (at 150Pa) Dimension duct connection [mm] Ø125 Ø150 and Ø160 Ø180 H x W x D [mm] 600 x 560 x x 675 x 420 (with bypass 500) 602 x 675 x 430 (with bypass 510) Weight [kg] Temperature efficiency [% per NEN 5138]

4 Ubbink HRV M300 and G400 4b R Ubbink HRV M300 and G400 2b/2o R DEMAND-CONTROLLED VENTILATION Normal operation is to divide the input ventilation air to suit the size of the various rooms to be supplied. As fresh outdoor air to those rooms is only really needed when they are occupied, Ubbink HRV s can incorporate demand-controlled ventilation which can be set to monitor room occupation (through CO 2 measurement) or set to operate at specific times using the programmable clock. A TNO certificate of equivalence indicates a significant energy advantage from such a controlled demand system. Setup with CO 2 -sensor Control box OpenTherm Ubbink HR HOW IT WORKS When the air quality is good, there is no need for ventilation - air quality deteriorates when rooms are occupied. When air quality deteriorates, the available ventilation air will be sent to the occupied room first. Only when that is insufficient will the quantity of ventilation air be increased. This means the available ventilation air is sent to the room where the most ventilation air is needed, so providing an intelligent, customised system. A lower ventilation flow rate also means a lower energy consumption. REMOTE CONTROL Communication between the various components can be arranged through the Zigbee protocol - a wireless communication system. All components,including the remote control panel, are connected to a wall socket. Ubbink HRV C180 4b R Sleeping zone CO2 sensor Damper Living zone Control signal CO2 sensor Setup with clock function OpenTherm KEY I II III IV V VI To dwelling To atmosphere From dwelling From atmosphere Electric connections Condensate discharge Control box Control signal Dimensions of Ubbink HRV C180, M300 and G400 (in mm) Ubbink HR Damper Living zone Sleeping zone Type A B C D E F G H I J K L M C M G Clock Operation - 3 options 1 Automatic based on occupation (CO 2 measurement). CO 2 sensors determine the ventilation air flow rate. At night, the ventilation in the living room is reduced to the minimum and conversely, can be increased in the bedrooms, without the high flow rate causing additional noise nuisance. 2 Automatic based on a time program (clock function). A menu enables adjustment of the control damper settings for every day. The user can set six time blocks per day. 3 Manual control. The fan setting can directly be changed by turning the rotary knob on the remote control. 4

5 ACCESSORIES FOR BALANCED VENTILATION WITH HEAT RECOVERY Ubbink Climate Systems have developed and selected appliance-specific accessories that can be used to create an excellent installed system. Starting points are quality and ease of use and assembly. BYPASS UNIT FOR NIGHT VENTILATION Ubbink HRV M300 and G400 are available ex factory with a bypass for night ventilation that shuts off almost completely. In summer, this bypass unit ensures that cool night air replaces (as far as possible) the indoor air that has been heated during the day. The air is routed through the bypass unit. The appliance comes with an automatic control system that opens and closes the bypass valve. A bypass unit can also be retrofitted by the installer or the user. This bypass unit circulates approx.. 70% of the input air around the Ubbink HRV heat exchanger. Note: not currently available for the Ubbink HRV C180 model. 3-WAY SWITCH WITH FILTER INDICATION The 3-way switch allows the user to choose between three modes: 1 absence mode; 2 presence mode; 3 cooking/showering mode (boost). The 3-way switch is connected quickly and easily on the outside of the appliance using a data cable and a connector. Additional switches can also be connected and fitted to any room in the dwelling. For convenience, a 3-way switch is available with a filter indicator light (shown below) which indicates when the filter requires cleaning. WIRELESS REMOTE CONTROL A wireless remote control is also available which can control the ventilation system from anywhere in the house without electric provisions. Several remote controls (transmitters) can be set for one receiver, for example in the bathroom and in the kitchen. ADDITIONAL CONTROL OPTIONS Ubbink HRV M300 and G400 can be extended with an optional pcb. This pcb can be used to control various accessories, for example a preheater and/or postheater (1000W), a damper for sending extra ventilation air to certain rooms or an emergency contact. In addition, the optional pcb has an input for a CO 2 sensor and a humidity sensor. Table 1: Sound pressure for Ubbink HRV M300 model Frequency [Hz] Tot [db(a)] 100m 3 /h, 40 Pa m 3 /h, 60 Pa m 3 /h, 160 Pa Table 2: Sound pressure for Ubbink HRV G400 model Frequency [Hz] Tot [db(a)] 100m 3 /h, 40 Pa m 3 /h, 60 Pa m 3 /h, 160 Pa ACOUSTIC INSULATION A good ventilation system should not cause noise nuisance. Based on laboratory and practice measurements, Ubbink can supply specially developed silencers and acoustic hoses that give the best results in combination with the Ubbink HRV. These silencers are available in Ø125mm, Ø150mm and Ø180mm in finished sections from 1m. Connection kits have been composed for ease of assembly of the Ubbink HRV. We strongly advise against the use of other acoustic hoses. SOUND ENGINEERING DATA When using 1m of Ubbink acoustic hose, the sound pressures shown in tables 1 and 2 can be expected in a living room (measured under ISO 7235), expressed in db(a). 5

6 HRV HEAT RECOVERY DUCT SYSTEM The insulated, HRV heat recovery synthetic duct system is available in Ø125mm, Ø150mm and Ø180 mm in lengths up to 2.25m and also includes long socket sleeves and compact bends in angles of 15, 30, 45 and 90. The availability of long sections and compact bends makes the HRV heat recovery duct system neat and tidy, very quick and easy to assemble, reduces wastage and makes the system perfect for use in complicated design installations. In addition, the ducts are easy to inspect and clean through a special inspection sleeve that can also be used as fixation bracket and the supplied cutting template ensures that the ducts can always be cut simply and correctly. The HRV heat recovery pipe is used for ducting air to and from the atmosphere and elsewhere in an unheated loft. SOUND REDUCTION The relatively soft EPE material offers additional sound absorption compared to more rigid materials such as metal and EPP. A comparative measurement of a 90 bend and 3 metres of duct on a heat recovery unit (at 225m 3 /h) shows an additional sound absorption of EPE compared to metal and EPP of 6dB(A) and 5dB(A) respectively. TO COMPLETE THE SYSTEM Ubbink have developed a comprehensive range of distribution ducts for the ventilation market, complete with all required accessories such as couplings, bends, connections and supply and extract valves. The sophisticated design, dimensions and spacers of the system result in a low air resistance - vital for the correct performance of the ventilation system. All the parts necessary for a complete installation of the system are available from Ubbink. Parts Insulated synthetic pipe and bends (45 and 90 ) with socket sleeves for the HRV heat recovery duct system. Flow resistance values (in Pa-static) Installation example The above installation shows the Ubbink HRV M300 2b/2o R model. The ducts to and from the atmosphere are from the HRV heat recovery duct system. The ducts to and from the dwelling are provided with acoustic flexible hose for sound absorption. HRV Heat recovery duct system Ø125mm at 150m 3 /h Ø150mm at 225m 3 /h Ø180mm at 325m 3 /h Pipe per metre Bend Bend Bend Bend

7 Ubbink HRV Compact C180 flow rates Ducts system resistance (Pa) Ducts system resistance (Pa) Ducts system resistance (Pa) Ubbink HRV Medio M300 flow rates Ubbink HRV Grande G400 flow rates Air volume (m 3 /h) Air volume (m 3 /h) Air volume (m 3 /h) 7

8 QUALITY & ENVIRONMENTALLY FRIENDLY PRODUCTS FOR TODAY'S ENERGY EFFICIENT BUILDINGS Ubbink have been manufacturing and supplying high quality and high performance products to the building and ancillary industries for over 30 years and have probably the most comprehensive range of building products available today. Advanced technology and innovative design ensures that our products bring real environment and economic benefits to both residential and commercial properties. Ease of installation is a key consideration during the product development process, while quality materials and rigorous manufacturing standards guarantee their durability. THE UBBINK RANGE Non-lead flashing Eaves and ridge ventilation Flat roof vents Tile and slate vents Breather membranes Non-permeable underlays Vapour control layers Heat reflecting membranes Flat roof windows Dry verge Pitched and flat roof terminals Whole house ventilation Heat recovery systems Heating flue systems Insulation trays Tubular skylights Valley troughs Loft hatches Sealants Ubbink (UK) Ltd Borough Road, Brackley, Northants NN13 7TB T: F: E: info@ubbink.co.uk W: For technical advice call Every effort has been taken in the preparation of this brochure to ensure the accuracy of representations contained herein. Recommendations as to the use of materials, construction details and methods of installation are given in good faith and relate to typical situations. However, every site has different characteristics and reliance should not be placed on the foregoing recommendations. Advice can be given as to specific applications of the products, upon request to Ubbink.

That allows for installation of a lowresistance ducts system directly from the appliance. CONSTANT FLOW FANS

That allows for installation of a lowresistance ducts system directly from the appliance. CONSTANT FLOW FANS Heat Recovery Units Balanced ventilation brings comfort and health to your home throughout the year. After all, wouldn t you like to always have plenty of clean, fresh air in your home? HRV ensures t hat

More information

Healthy, comfortable and energy-efficient ventilation

Healthy, comfortable and energy-efficient ventilation Healthy, comfortable and energy-efficient ventilation 300/400/450 180 Renovent Excellent 180, 300, 400 and 450 Silent and energy-efficient ventilation Central ventilation The Renovent Excellent is a mechanical

More information

Healthy, comfortable and energy-efficient ventilation

Healthy, comfortable and energy-efficient ventilation Healthy, comfortable and energy-efficient ventilation partner Renovent Excellent 180, 300 and 400 Silent and energy-efficient ventilation 300/400 180 Central ventilation The Renovent Excellent is a mechanical

More information

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system Viewpoint August 2012 Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system Dr Sarah Price and Helen Brown Summary Mechanical Ventilation and Heat

More information

BRINK Renovent HR Installation and Operation Manual

BRINK Renovent HR Installation and Operation Manual BRINK Renovent HR Installation and Operation Manual Table of contents Chapter Application 1 1 Page Version Ducts connection options FIlter door position options Bypass Technical information Fan graphs

More information

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range & 300 Exceptionally low energy consumption High Efficiency, Low Profile Heat Recovery Range & 300 High Efficiency, Low Profile Heat Recovery Range High-efficiency, low profile MVHR units to deliver exceptionally

More information

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION 2 AERECO DX system DX SYSTEM A COMPLETELY NEW HEAT RECOVERY VENTILATION RANGE With the experience of a very innovative room-by-room demand

More information

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

Itho Advance heat recovery ventilation unit. comfortable. indoor climate Itho Advance heat recovery ventilation unit comfortable indoor climate Advance heat recovery ventilation unit In order to make modern dwellings more energy efficient the insulation and air tightness has

More information

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT - WHOLE HOUSE HEAT RECOVERY UNIT 95% efficient, SAP Appendix Q compliant heat recovery unit.. 29 285 82 BENEFITS High efficiency 95% efficient, with DC motors using 5% less energy than traditional fans.

More information

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW NEW HRU ECO 3 RF ULTRA HIGH EFFICIENCY (95%) WHOLE HOUSE HEAT RECOVERY VENTILATION SYSTEM (MVHR) COMPLYING WITH SYSTEM 4 OF ADF2006 VENTILATION AIR CONDITIONING AIR CLEANING HEATING APPENDIX Q ELIGIBLE

More information

energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System

energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System energisava 200 High Efficiency Whole House Heat Recovery System Joining the high efficiency energisava

More information

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units CI/SfB (57.7) 1st Edition Vent-Axia MVHR Units Vent-Axia Sentinel Kinetic Horizontal Range Lo-Carbon Sentinel Kinetic Horizontal MVHR Units Features & Benefits Manufactured in the UK Building Regulations

More information

Lo-Carbon Sentinel Kinetic Horizontal

Lo-Carbon Sentinel Kinetic Horizontal Lo-Carbon Sentinel Kinetic Horizontal MVHR Unit Features & Benefits Manufactured in the UK Building Regulations ADF compliant Recognised in SAP Appendix Q Energy Savings Trust best practice compliant Up

More information

ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION

ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION 2 AERECO Room-by-room demand controlled heat recovery ventilation REVOLUTION IN THE WORLD OF HEAT RECOVERY VENTILATION Through its new ventilation

More information

VENTILATION DESIGNED FOR CARE HOMES

VENTILATION DESIGNED FOR CARE HOMES CI/SfB (57) Uniclass Pr_65_67_29 October 2017................................ ............................................................................. Contents Ventilation designed for Care Homes

More information

Zehnder Comfosystems. ComfoAir 180 Datasheet

Zehnder Comfosystems. ComfoAir 180 Datasheet Zehnder Comfosystems Heating Cooling Fresh Air Clean Air ComfoAir 180 Datasheet Zehnder Comfosystems ComfoAir 180 Physical specifications The Zehnder ComfoAir 180 heat recovery ventilation system is an

More information

2013 innovation. Room-by-room demand controlled heat recovery ventilation

2013 innovation. Room-by-room demand controlled heat recovery ventilation 2013 innovation Room-by-room demand controlled heat recovery ventilation 2 Revolution in the world of heat recovery ventilation Through its new ventilation system, which combines heat recovery and room-by-room

More information

COUNTER-FLOW, HIGH-EFFICIENCY HEAT RECOVERY UNIT IDEO ECOWATT

COUNTER-FLOW, HIGH-EFFICIENCY HEAT RECOVERY UNIT IDEO ECOWATT Whole house heat recovery unit with a high-efficiency heat exchanger up to 92% with constant airflow setting, very low consumption EC motor and low sound level. Provides a constant supply of fresh tempered

More information

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW NEW HRU ECO 3 RF ULTRA HIGH EFFICIENCY (95%) WHOLE HOUSE HEAT RECOVERY VENTILATION SYSTEM (MVHR) COMPLYING WITH SYSTEM 4 OF ADF2006 VENTILATION AIR CONDITIONING AIR CLEANING HEATING APPENDIX Q ELIGIBLE

More information

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems energisava 300 & 400 High Efficiency Whole House Heat Recovery Systems Providing all year round good indoor

More information

Renovent Excellent 450 (Plus)

Renovent Excellent 450 (Plus) Renovent Excellent 450 (Plus) INSTALLATION INSTRUCTIONS (English) 614298-B Installation instructions Heat recovery appliance Renovent Excellent 450 (Plus) STORE NEAR THE APPLIANCE This appliance can be

More information

HRXD MVHR UNIT Mechanical Ventilation with Heat Recovery.

HRXD MVHR UNIT Mechanical Ventilation with Heat Recovery. HRXD MVHR UNIT 2018 Mechanical Ventilation with Heat Recovery 1 All prices quoted exclude VAT and do not include trade discounts. www.domusventilation.co.uk HRXD Range HRXD MVHR Mounts onto a wall in either

More information

Small Room Heat Recovery Ventilation

Small Room Heat Recovery Ventilation Small Room Heat Recovery Ventilation Ideal for smaller spaces that would benefit from heat recovery, such as staff rooms or offices Version 3.1 2 Breathing Buildings Small Room Heat Recovery 3 Small Room

More information

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation

More information

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual 90000556/90000557 Issue 10 9/17 MODEL: DV72 R & L Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation:

More information

Renovent Excellent 180 (Plus)

Renovent Excellent 180 (Plus) Renovent Excellent 180 (Plus) INSTALLATION INSTRUCTIONS (English) WWW.BRINKAIRFORLIFE.NL 614293-D Installation instructions Heat recovery appliance Renovent Excellent 180 (Plus) STORE NEAR THE APPLIANCE

More information

IDEO 325 ECOWATT. Counter-flow, high-efficiency heat recovery unit IDEO 325 ECOWATT. Low noise. Heat recovery units. Wireless programmable control

IDEO 325 ECOWATT. Counter-flow, high-efficiency heat recovery unit IDEO 325 ECOWATT. Low noise. Heat recovery units. Wireless programmable control Counter-flow, high-efficiency heat recovery unit Whole house heat recovery unit with a high-efficiency heat exchanger up to 92% with constant flow, setting and very low consumption DC motor. Provides a

More information

WHHR Midi & Midi Lite

WHHR Midi & Midi Lite WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page

More information

Thank you for choosing EnviroVent

Thank you for choosing EnviroVent 01 Introduction Thank you for choosing EnviroVent The fastest growing ventilation company in the UK You are about to install a product that is designed to outlast the life-cycle of the building. Once installed

More information

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 800 m /h COMFORT 00 Product description The Comfort 00 is an energy-efficient ventilation

More information

MODEL: BV400 Part No:

MODEL: BV400 Part No: MODEL: BV400 Part No: 90000312 Mechanical Ventilation with Heat Recovery Installation and Commissioning Manual PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT INDEX 1. Introduction... 3 2. General Instructions...

More information

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation NUAIRE MVHR and Opposite Handed version ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due to its intelligent

More information

Thank you for choosing EnviroVent

Thank you for choosing EnviroVent 01 Introduction Thank you for choosing EnviroVent The fastest growing ventilation company in the UK You are about to install a product that is designed to outlast the life-cycle of the building. Once installed

More information

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS. Installation Guide This information is provided as a guide and may differ from project to project. It is assumed that the property is a two storey dwelling. Obviously a bungalow represents a simpler task,

More information

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO3 MRXBOX-ECO3 NUAIRE MVHR MRXBOX-ECO3 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

MRXBOXAB-ECO2 MRXBOX-ECO2

MRXBOXAB-ECO2 MRXBOX-ECO2 NUAIRE MVHR MRXBOX-ECO2 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit DC Heat Recovery Unit MVHR Wholehouse heat recovery unit Stock Ref. N DC Heat Recovery Unit MVHR 443423 Installation, Maintenance & Users Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

More information

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR) Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR) Contractors Requirements & Competency This section outlines the general Standards

More information

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION

More information

Kair. ieco 4 RANGE. Appendix Q Eligible VENTILATION LIMITED. Continuous Mechanical Supply and Extract Ventilation with Heat Recovery

Kair. ieco 4 RANGE. Appendix Q Eligible VENTILATION LIMITED. Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Kair VENTILATION LIMITED ieco 4 RANGE Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible Weight As a result of the unique clamping construction in combination with

More information

Introducing the RetroVent

Introducing the RetroVent Fans For Life Introducing the RetroVent Features Benefits Made in the UK Flying the flag for UK manufacturing, lower carbon footprints and total control over quality Tubular heat recovery cell Designed

More information

Air Excellent AE55SC. Technical Datasheets

Air Excellent AE55SC. Technical Datasheets Air Excellent AE55SC Technical Datasheets AE55SC semi-circular ductwork (60 x 132 mm) 1 2 Introduction The Air Excellent semi-circular ductwork ensures efficient air distribution between distribution boxes

More information

Air Excellent AE45SC. Technical Datasheets

Air Excellent AE45SC. Technical Datasheets Air Excellent AE45SC Technical Datasheets Air Excellent AE45SC semi-circular ductwork (50 x 140 mm) 1 2 Introduction The Air Excellent semi-circular ductwork ensures efficient air distribution between

More information

HOTLINE:

HOTLINE: You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 5 years and beyond without a major service. Please therefore

More information

i PSV WHOLE-HOUSE VENTILATION SYSTEM

i PSV WHOLE-HOUSE VENTILATION SYSTEM CI/SfB (57) Uniclass Ss_65_40_33_56 November 2017 i PSV WHOLE-HOUSE VENTILATION SYSTEM Humidity-sensitive wall ventilator Energy saver vent................................ HOW TRADITIONAL PASSIVE STACK

More information

Renovent Sky 300 (Plus)

Renovent Sky 300 (Plus) Renovent Sky 300 (Plus) INSTALLATION INSTRUCTIONS (English) WWW.BRINKAIRFORLIFE.NL 612378-E Renovent Sky 300 (Plus) STORE NEAR THE APPLIANCE This appliance can be used by children aged from 8 years and

More information

CVE ECO 2 Range. System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible

CVE ECO 2 Range. System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible CVE ECO 2 Range System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible CVE ECO 2 Applications The Itho extractor unit model CVE ECO 2 has been developed for use as a very quiet and

More information

INSTALLATION AND MAINTENANCE INSTRUCTION (ENGLISH VERSION) dx system DXA 230 PREMIUM. Heat recovery unit with demand control for cupboard installation

INSTALLATION AND MAINTENANCE INSTRUCTION (ENGLISH VERSION) dx system DXA 230 PREMIUM. Heat recovery unit with demand control for cupboard installation INSTALLATION AND MAINTENANCE INSTRUCTION (ENGLISH VERSION) dx system DXA 230 PREMIUM Heat recovery unit with demand control for cupboard installation 2 / 36 1. Introduction 3 1.1. Warnings 3 1.2. Pictograms

More information

Installation and Maintenance

Installation and Maintenance 38 70 = 100 410 = 60 1.0 INTRODUCTION MRXBOXAB-ECO4-AESW (Standard Unit) MRXBOXAB-ECO4-AEOHSW (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for Wall Mounting Installation and Maintenance

More information

The Sentinel Kinetic Horizontal Range

The Sentinel Kinetic Horizontal Range Lo-Carbon Sentinel Kinetic Horizontal Features & Benefits Manufactured in the UK Building Regulations DF compliant Recognised in SP PCDB Energy Savings Trust best practice compliant Up to 81% heat recovery

More information

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation Residential Carbon Friendly Ventilation SAP Q Eligible ventilation Whole House Mechanical Ventilation - MVHR, MEV, dmev SAP Q ELIGIBLE PRODUCTS Energy Efficient Ventilation About Appendix Q SAP is the

More information

Airflex Radial & ISO Thermal pipe

Airflex Radial & ISO Thermal pipe Airflex Radial & ISO Thermal pipe Semi rigid ducting Key Features Zero leakage ensures highest performance 70% time saving on installation Interchangeable ducting system (75mm round / 51mm x 114mm oval)

More information

Technical documentation Comfort domestic ventilation system

Technical documentation Comfort domestic ventilation system Technical documentation Comfort domestic ventilation system CWL Excellent CWL-T Excellent CWL-F Excellent 2 CWL unit options Type CWL-F-150 Excellent CWL-F-300 Excellent CWL-180 Excellent CWL-300 Excellent

More information

Installation and Maintenance

Installation and Maintenance 1.0 Introduction MRXBOX-ECO2 (Standard Unit) MRXBOX-ECO2-OH (Opposite hand Unit) MRXBOXAB-ECO2 (Standard Unit) MRXBOXAB-ECO2-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for

More information

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION CHECK LIST Make

More information

Ventilation Product range ADVANCE ECO 4 ECO 2

Ventilation Product range ADVANCE ECO 4 ECO 2 Product range ADVANCE ECO 4 ECO 2 Air, we breathe it without thinking. Keeping it that way in the modern, airtight homes calls for class-leading ventilation performance and you will find this with the

More information

Technical Information HXV - HRV Ventilation

Technical Information HXV - HRV Ventilation Technical Information HXV - HRV Ventilation General description Technical data Accessories VENTILATION HXV 5 1 General description 1.01-1.02 2 Technical data 2.01-2.02 3 Accessories 3.01-3.03 HRV 5 4 General

More information

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h PRODUCT DATA COMFORT 5000 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 5300 m 3 /h COMFORT 5000 The Comfort 5000 is a ventilation unit suitable for central

More information

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions) NUAIRE MVHR (including opposite handed versions) ACHIEVES 100% DUTY IN BYPASS MODE and MRXBOXAB- ECO-LP1-OH are specically designed for apartment applications where space is a premium. The new MRXBOX95-LP1

More information

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units Product Manual ventilation systems 2 PCT Patent Application No PCT/GB2009/000114 Contents Introduction...................................

More information

Apartment Ventilation. "Microbox" Continuous Mechanical Extract Units

Apartment Ventilation. Microbox Continuous Mechanical Extract Units Apartment Ventilation "Microbox" Continuous Mechanical Extract Units v e n t i l a t i o n IPX4 Vectaire Ltd is a member of: ; Fan Manufacturers Association; Smoke Control Association; Residential Ventilation

More information

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery. PRODUCT DATA COMBI 300 POLAR BY NILAN Ventilation with passive & active heat recovery Domestic Passive heat recovery Active heat recovery Ventilation < 350 m 3 /h Comfort heating Comfort cooling COMBI

More information

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h PRODUCT DATA COMFORT 300 TOP BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 325 m 3 /h COMFORT 300 TOP Product description The Comfort 300 Top is an energy-efficient

More information

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h PRODUCT DATA COMFORT 450 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 450 m 3 /h COMFORT 450 Product description The Comfort 450 is an energy-efficient ventilation

More information

CI/SfB (57) Uniclass Pr_30_59_96 December 2017 TRICKLE VENTILATORS...

CI/SfB (57) Uniclass Pr_30_59_96 December 2017 TRICKLE VENTILATORS... CI/SfB (57) Uniclass Pr_30_59_96 December 2017 TRICKLE VENTILATORS... ................................................ TRICKLE VENTILATORS..................................................................

More information

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system Heat Recovery Ventilation Applicable to aircycle 1.1/1.2 (Ws - For Wall Mounting with In-built Control & Summer Bypass) Installation and Maintenance Instructions for the Installer. Please refer to the

More information

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 % Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed

More information

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 00 m /h COMFORT 00 The Comfort 00 is a ventilation unit suitable for central ventilation

More information

Application and Installation Guide (excluding Solar Air Collectors)

Application and Installation Guide (excluding Solar Air Collectors) Application and Installation Guide (excluding Solar Air Collectors) Manual Number 671276 September 2011 The EMC Directive 89/336/EEC With modification 92/31/EEC The Low Voltage directive 2006/95/EEC Application

More information

Endura Delta. Demand- and app-controlled ventilation system with heat recovery

Endura Delta. Demand- and app-controlled ventilation system with heat recovery Endura Delta Demand- and app-controlled ventilation system with heat recovery Introduction < Endura Delta As an occupant we are increasingly aware of the fact that energy-efficient construction should

More information

HRV Enthalpy. Catalogue

HRV Enthalpy. Catalogue HRV Enthalpy Catalogue BM896 Iss 02 - Enthalpy MVHR Contents HRV1.35 Q Plus - Enthalpy...3 HRV2 Q Plus - Enthalpy...5 HRV3 Q Plus - Enthalpy...7 HRV10.25 Q Plus - Enthalpy...9 Heat Water vapour Gases and

More information

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing Field of application Description Advantages Range Technical details Installation Remote controls Servicing Remote control ErP * ** Conpliance compliance. ErP ready. Advantages Reversible connections. Ventilation

More information

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Purge Ventilation Unit. Product Manual. ventilation systems TP625 EN Purge Ventilation Unit TP625 Product Manual ventilation systems Warnings, Safety Information and Guidance Important Information Important: read these instructions fully before the installation of this

More information

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR Whole House Mechanical Ventilation with Heat Recovery - MVHR WHHR125DC - Aera This MVHR - WHHR125DC - Aera - is an efficient, low energy solution to controlling condensation and pollution. It provides

More information

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) IMPROVING INDOOR AIR QUALITY IN NEW HOMES 1 NUAIRE S PEDIGREE Proud to Build British Nuaire is a world leader in the design and manufacture of fans and

More information

BUILDING STANDARDS SUPPORTING GUIDANCE DOMESTIC VENTILATION

BUILDING STANDARDS SUPPORTING GUIDANCE DOMESTIC VENTILATION BUILDING STANDARDS SUPPORTING GUIDANCE DOMESTIC VENTILATION 2 ND EDITION 1 Contents 1. Purpose of this document 3 Page 2. Ventilation 4 3. Purpose provided ventilation 6 4. Natural ventilation- windows,

More information

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION

More information

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS enthalpy membrane in the warm season. This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the

More information

Installation and Maintenance

Installation and Maintenance 1.0 INTRODUCTION MRXBOXAB-ECO-LP1SW (Standard Unit) MRXBOXAB-ECO-LP1-OHSW (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The

More information

CI/SfB (57.7) 2nd edition. Lo-Carbon Quadra

CI/SfB (57.7) 2nd edition. Lo-Carbon Quadra CI/SfB (57.7) 2nd edition Lo-Carbon Quadra Vent-Axia Quadra An Evolution in Residential Ventilation, Designed especially for Social Housing One fan fits all Happy Installers The fan that fits anywhere,

More information

Air Comfort. Installation instructions (English) A

Air Comfort. Installation instructions (English) A Air Comfort Installation instructions (English) WWW.BRINKAIRFORLIFE.NL 614788-A This appliance may be used by children as of 8 years of age, persons of reduced mental or physical capacities and those of

More information

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE NEW ECO RANGE MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) Mechanical Ventilation with Heat Recovery Proud to Build British u Nuaire is a world leader in the design and manufacture of fans and ventilation

More information

Whole Home Heat Recovery Ventilation

Whole Home Heat Recovery Ventilation Whole Home Heat Recovery Ventilation Lossnay VL220. Clean Fresh Air; for a Healthier, Drier and Warmer Home. Balanced Pressure Home Ventilation. Made in Japan, Designed for New Zealand Conditions. Lossnay

More information

ENERGY RECOVERY VENTILATION (ERV)

ENERGY RECOVERY VENTILATION (ERV) Home/Other Products/Obsolete Ranges ENERGY RECOVERY VENTILATION (ERV) 2 model sizes covering 500 to 1500m3/hr Choice of 90% or 55% efficient aluminium energy recovery cell High performance EC/DC motors

More information

Installation and Maintenance

Installation and Maintenance MRXBOXAB-ECO4-SW (Standard Unit) MRXBOXAB-ECO4-OHSW (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery and Heat Exchanger Bypass for Wall Mounting The EMC Directive 014/30/EU The Low

More information

Installation and Maintenance

Installation and Maintenance MRXBOXAB-ECO4 (Standard Unit) MRXBOXAB-ECO4-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery and Heat Exchanger Bypass for Wall Mounting Installation and Maintenance The EMC Directive

More information

DEMAND CONTROLLED HOME VENTILATION HCC 2 Designed to suspended ceiling installation

DEMAND CONTROLLED HOME VENTILATION HCC 2 Designed to suspended ceiling installation DEMAND CONTROLLED HOME VENTILATION HCC 2 Designed to suspended ceiling installation DEMAND-CONTROLLED HOME VENTILATION No more worrying about the indoor climate The indoor climate must be taken seriously

More information

Technical Sheet. Heat recovery appliance Renovent Excellent 400 (Plus) Renovent Excellent 400 1

Technical Sheet. Heat recovery appliance Renovent Excellent 400 (Plus) Renovent Excellent 400 1 Technical Sheet Heat recovery appliance Renovent Excellent 400 (Plus) Renovent Excellent 400 1 Application The Brink Renovent Excellent is a ventilation unit with heat recovery with an efficiency of 95%,

More information

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2 NUAIRE S MVHR Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2 Nuaire s First Fix and Acoustic Solution are designed to not only reduce noise but to improve the installation when wall or cupboard

More information

DEMAND-CONTROLLED HOME VENTILATION

DEMAND-CONTROLLED HOME VENTILATION DEMAND-CONTROLLED HOME VENTILATION DEMAND-CONTROLLED HOME VENTILATION No more worrying about the indoor climate The indoor climate must be taken seriously A good indoor climate is all about health and

More information

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM SOLAR PRE-HEAT VENTILATION SYSTEM SUNWARM USES SOLAR ENERGY TO REDUCE THE HEATING DEMAND OF THE HOME AS WELL AS PROVIDING A COMPLETE VENTILATION SOLUTION. 76 BENEFITS Sunwarm Air provides both a ventilation

More information

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

WHHR125DC Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use "WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor Installation, Operating and Maintenance Instructions domestic and commercial use Page 2 Contents Section Page Number Introduction 3 How

More information

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 Single-room heat recovery unit Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 CONTENTS FRESHBOX 100 FEATURES 3 DESIGN 4 OPERATING PRINCIPLE 6 CONTROL 6 APPLICATION

More information

Building Regulations Approved Document F1 Means of Ventilation April 2006

Building Regulations Approved Document F1 Means of Ventilation April 2006 Building Regulations Approved Document F1 Means of Ventilation April 2006 BPD Structure BUILDING PRODUCT DESIGN LTD 4 trading divisions.. Natural ventilation products and systems Roofing products, flat

More information

Intelligent Air Solutions

Intelligent Air Solutions Uniclass L75 CI/SfB (57) X HRX-aQSB. May 06 Intelligent Air Solutions QUIET COMPACT EFFICIENT MANUFACTURED IN THE UK Applications Suitable applications Introducing Polypipe s new and highly efficient Silavent

More information

Installation and Maintenance

Installation and Maintenance 1.0 INTRODUCTION MRXBOXAB-ECO-LP1 (Standard Unit) MRXBOXAB-ECO-LP1-OH (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The LP1

More information

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE NEW VORT PROMETEO HR 400 HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE VENTILATION AIR CONDITIONING AIR CLEANING HEATING 2 VORT PROMETEO HR 400 (Code 11815) Quiet, Effective Ventilation in Full Compliance with

More information

MRXBOX90S. Mechanical Ventilation with Heat Recovery. Installation and Maintenance

MRXBOX90S. Mechanical Ventilation with Heat Recovery. Installation and Maintenance MRXBOX90S Mechanical Ventilation with Heat Recovery Installation and Maintenance The EMC Directive 2004/08/EC The Low Voltage directive 2006/95/EC.0 Introduction The Nuaire MRXBOX90S is a heat recovery

More information

Wall Hung Condensing Boilers. Working towards a cleaner future. heating specialists

Wall Hung Condensing Boilers. Working towards a cleaner future. heating specialists Paramount two Wall Hung Condensing Boilers Working towards a cleaner future heating specialists Product Overview page 3 Introduction 4 Benefits System & Applications 5 System Requirements 5 Single Boiler

More information

Ventilation & Heat Recovery. The whole house system from OMNIE

Ventilation & Heat Recovery. The whole house system from OMNIE Ventilation & Heat Recovery The whole house system from OMNIE 2 Contents ABOUT OMNIE 4 The Whole house system 6 Why OMNIE Ventilation & Heat Recovery? 7 How does it work? PRODUCT 9 Comfo Air Q MVHR Unit

More information