JSI-UV canopy - Ultraviolet and cyclonic filters, and supply air JSI-UV hoods Product Description Lights and filters
|
|
- Brenda Matilda Conley
- 5 years ago
- Views:
Transcription
1 JSI-UV canopy - Ultraviolet and cyclonic filters, and supply air Product Description The Jeven JSI-UV canopy has been designed for kitchens where a comfortable, productive and healthy indoor climate is required. JSI-UV is equipped with exhaust, supply and direction air. Unique draftless supply air diffusion and effective grease extraction provide a comfortable and pleasant working environment. UV supply air hoods are suitable for professional kitchens where effective grease extraction is needed. In addition to JCE cyclone filters, the JLI-UV hood also has a UV-filter unit for removing grease and impurities from the exhaust air. In island models the supply air units can be located on all sides of the canopy. Supply air patterns are easy to adjust and the supply air unit's front panel can be removed and washed in a dishwasher, just like the JCE cyclone filters and the mesh filter. The hood is equipped with airflow damper plates and measurement taps on both the exhaust and supply air. Lights and filters The JSI-UV hood comes with ultraviolet (UV) filters, JCE cyclonic filters, a stainless steel net filter, a pressure guard switch and lights. The UV filter unit includes a UV frame with UV-tubes, as well as a UV control unit and panel. Material The supply air hood's base material is stainless steel (AISI 0). Wall materials can be either stainless steel or laminated glass. Accessories Covering boards from the hood's top edge to the false ceiling. Product Code UV-Supply Air Hood JSI-R-UV 000x00x0 - x0 - x m/s - 0. m/s Wall material R=Stainless steel S=Glass UV=UV-filter unit Length Width Height Number and size of the supply air spigots Number and size of the exhaust air spigots Supply air flow, m/s Exhaust air flow, m/s Phone: 0 9 0
2 Functioning principle of the JSI-UV canopy. Supply air is distributed through supply air units.. Kitchen staff can adjust the air pattern with the individual nozzles.. Heat and impurities rise into the hood.. Direction air prevents air leakages and directs heat and impurities towards the grease filters.. The effective -phase UV filter extracts grease and dirt from the exhaust air.. Clean air leaves the filter. Functioning principle of the UV filter unit PHASE. Grease laden air enters the filter.. Grease particles are extracted as the air spins in a cyclone (>µm particles). Grease drains down to the bottom of the filter unit. PHASE. When air flows through the wire mesh filter, the temperature goes down and a smooth air stream is created. Some of the remaining smaller particles are separated. Phone: PHASE. Ultraviolet light and ozone are generated by UVfluorescent tubes placed in the reaction chamber. When the air stream meets UV light and ozone, the remaining grease and odour decompose and break down. Only carbon dioxide, water and a small amount of dust remain.. Clean air is released into the exhaust ducts.
3 Parts of the JSI-UV canopy Outer casing. Supply air connection and air volume control. Light fixture. Light cable (approx m). UV filter unit. Direction air unit with measurement tap for the supply air flow. Exhaust air connection and the air volume control. Personal supply air nozzles 9. Fascia of the supply air unit (detachable) 0.Ceilling console.hanging bracket.pressure sensor.pressure measuring hosepipe.uv control centre.uv touch screen.control panel s cable.wire from the UV unit to the control centre..main power cable (must be equipped with a safety fuse) 9.Wire from the pressure sensor to the UV-control centre. Phone: 0 9 0
4 Parts of the UV filter unit UV+mesh filter chamber Exhaust air connection and airflow damper Stainless steel frame with UV-lamps Cyclone filters Measurement tap for exhaust airflow Table for calculation of the airflow rate Mesh filter Cleaning door Phone: 0 9 0
5 Dimensions ØD K B E A height F E width A A-A 0 JSI-UV wall hood C (module) M length length G JSI-UV island type hood The canopy's length, width, and C and E dimensions can be freely chosen at 00 mm intervals, taking into account the following limitations: - Minimum module size: 00mm x 00mm - Maximum module size: 000mm x 00mm - Standard heights: 0mm and 0mm. Ø 00 B Height F ØD G Emin Kmin mm mm mm mm mm mm mm M mm E width C ØD K E B (module) Custom solutions are available from the Jeven Design Service Department and will be designed to suit individual requirements. length The Design Service Department can be contacted on and design@jeven.co.uk UV filter unit Ø Phone: 0 9 0
6 Recommended supply airflow rates Recommended supply airflow rates per supply air unit. The recommended supply air for the hood is 0-90 % of the hood's exhaust airflow, which is based on the convection airflow of the kitchen devices below the canopy. Hood height Supply air unit width (B) Hood heigth mm mm mm m/s m/s m/s m/s mm 0 0 Supply air unit width (B) 00 mm 0-0 m/h 0-0 m/h mm 0-0 m/h 0-0 m/h The hood is preset at the factory to be ready to use with a project-specific airflow for a pressure drop of - Pa. Pressure loss, Sound data and Throw length / Supply air unit Spigot Ø 0 mm Unit width 00 mm Hood height 0 mm Damper / closed Spigot Ø 00 mm Unit width mm Hood height 0 mm. Damper / closed Damper open LpA =db - 0, 0 0 L0, (m), LpA =0dB 0 LpA =db 0 LpA =0dB [m /s] m/h L0, (m) 0, 0,, ± ± LpA =db LpA =0dB 0 LpA =db 0 LpA =0dB [m /s] m/h L0, (m), ± Damper open Damper / closed 0 LpA =0dB LpA =db 0 LpA =0dB [m/s] m/h 0, 0, LpA =db - 0 ± Damper open ± Spigot Ø 0 mm Unit width mm Hood height 0 mm. Spigot Ø 0 mm Unit width 00 mm Hood height 0 mm. Damper / closed LpA =db LpA =0dB 0 LpA =db 0 LpA =0dB [m /s] m/h 0, Damper open , 0, , L0, (m) ± The sound power level (Lw) in each octave band is computed by adding the corresponding factor to the sound pressure level (LpA), as in Lw = LpA + Phone: 0 9 0
7 Exhaust flow rates Exhaust air flows are calculated according to the DW/ standard, based on the type, size and power source of the kitchen equipment located under the canopy. Coefficient Kitchen equipm. C Size Power source Exhaust mm x mm gas/electric m/s Objectives of kitchen ventilation Total. m/s The Jeven free design service team can help you with these calculations. Simply a drawing of the kitchen and the list of cooking equipment to design@jeven.co.uk and we will calculate all the necessary airflows and also prepare a drawing of the canopies for you for free.. Cooking vapours and heat should be removed with the help of efficient local exhaust in such a way that contaminants do not pass though the staff s breathing zone.. Temperature, velocity and cooling effect of the supply air should be comfortable.. In cases where staff are subjected to high heat radiation, they should be able to adjust the supply air (local cooling). Grease extractors should be fire-proof and, as with supply air units, should be easy to maintain.. Air flow rates should be easily adjustable. Recommended exhaust air flows / UV-unit Pressure loss and Sound data Number of cyclones 0 00 Our design service team makes a tailored solution for your kitchen, taking into account the cooking equipment and all the available information about the kitchen. We also provide CAD drawings of the new canopies, so you have a complete solution. Contact the Jeven design team today: design@jeven.co.uk Pressure loss The Jeven free design service helps you calculate the necessary airflows for your kitchens and can also provide drawings. This saves you lots of time. Airflow rate Number of m/s m/h cyclones db(a) = db(a) =0 Power of the UV-lamps x9w=w x9w=w x9w=w x9w=w x9w=w m/s m/h Sound power level, Lw The sound power level (Lw) for each octave band is calculated by adding the corresponding factor () to the sound pressure level (LpA), as in Lw = LpA + The number of cyclones depends on the air outflow. The nominal airflow per cyclone is about 0.0 m/s (0 m/h). With that airflow, the pressure difference across the cyclone is 0-0 Pa. The factory always delivers an appropriate number of cyclones so that the pressure drop in every cyclone is in that range (unless otherwise agreed). units of 9W UV lamps are always included. The UV filter unit's exterior dimensions are always the same. factor ± Phone: 0 9 0
8 Ultraviolet light The UV filter unit works on a photo oxidation basis, and generates ozone with the help of ultraviolet lamps. As a joint effect of ozone and ultraviolet light, grease produced during cooking is turned into oxygen, carbon dioxide, water and a polymerised (dust-like) grease. Odour molecules are oxidised into water and carbon dioxide. In the UV filter unit, ultraviolet light breaks down the protein chains in the grease molecules, so it is easy for ozone to react with these now smaller molecules. UV-lamps x9w in the UV-frame. Full realisation of the process requires at least two seconds of ozone time, so the exhaust ductwork must be sufficiently long. Extra ozone created during the process turns back into oxygen. It is dangerous to look at blue ultraviolet light without safety glasses. Never look directly at the light source for more than three seconds without safety glasses. UV filter units are always delivered with a pressure sensor, which ensures that the exhaust fan is running when ozone is created. This prevents ozone from leaking into the kitchen if for any reason the exhaust fan stops. Deliveries always include a UV touch screen, which is used to turn the unit on and off Instructions Installation instructions with switch diagrams as well as maintenance and usage instructions are always delivered to the workplace in the main delivery. The UV frame and its lamps are easy to install and maintain. Phone: 0 9 0
9 Light fixture 0 B ) Light fixture, as standard, IP T B= mm, ( xw, xw, xw ) B= mm, ( xw, xw, xw ) T B= 0 mm, ( xw, xw, x9w ) B= 0 mm, ( xw, xw, x9w ) ) ca. m cable, type EKK x. By default, every hood module comes with a light fixture. The light fixture has a cable, which should be connected to a junction box with a cable lock. The junction box is not included. We reserve the right to make changes to products without prior notice Phone:
UV-TURBO HOODS. Product Brochure
UV-TURBO HOODS Product Brochure TABLE OF CONTENTS FUNCTIONING PRINCIPLE... 0 PRODUCT CODE... 0 PRODUCT STRUCTURE... 06 UV-TURBO GREASE FILTER... 07 EXHAUST AIR... 08 SUPPLY AIR... 09 LIGHTS... 0 DIENSIONS...
More informationTURBO HOODS. Product Brochure
TURBO HOODS Product Brochure TABLE OF CONTENTS FUNCTIONING PRINCIPLE... 04 PRODUCT CODE... 0 PRODUCT STRUCTURE... 06 TURBOSWING GREASE FILTER... 07 EXHAUST AIR... 08 SUPPLY AIR... 09 LIGHTS... 0 DIENSIONS...
More informationExcellent Ventilation for Professional Kitchens
www.jeven.com Excellent Ventilation for Professional Kitchens www.jeven.com Everyone Loves Good Food... but in order for the food to be good, not only do you need to know how to make it, but you also need
More informationKVF - Capture Jet canopy with Supply Air and Side-Jet Technology KVF. Capture Jet Canopy with Supply Air and Side-Jet Technology
KVF Capture Jet Canopy with Supply Air and Side-Jet Technology ALLIED EBER R LISTED HACCP* certified (PE-567-H01I). 30 to 40% reduction in exhaust airflow rates thanks to the Capture Jet technology. High-efficiency
More informationSupply air hood JSI-UV Installation-, adjustment and user guide
Supply air hood JSI-UV Installation-, adjustment and user guide PAGE Table of Contents Installation of hanging brackets Fixture points and connecting the hood modules 4 Installation of glasses 5 Light
More informationUVF - Capture Jet canopy combined with Capture Ray TM technology and low velocity supply air UVF
UVF Capture Jet canopy combined with Capture Ray TM technology and low velocity supply ALLIED MEMBER R LISTED HACCP* certified (PE-567-HM01I). to % reduction in exhaust airflow rates thanks to the Capture
More informationKITCHEN EXTRACTORS K Series
KITCHEN EXTRACTORS K Series CK-4F CK-5 CK-6F Description Construction The K Series range of centrifugal extractors are specifically designed for the extraction of moist, grease laden air and fumes from
More informationNORDcanopy Kitchen ventilation
NORcanopy Kitchen ventilation Contents General NORcanopy KS Kitchen hood for supply and exhaust air KV Kitchen hood for exhaust air KTS Kitchen hood for supply air KTV Kitchen hood KVM Exhaust air module
More informationJSKI Installation-, adjustment and user guide
JSKI Installation-, adjustment and user guide PAGE Table of Contents Installation of hanging brackets Fixture points and connecting the hood modules 4 Light fittings 5 Installation of covering boards 6
More informationFRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %
Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed
More information(INDUSTRIAL) KITCHEN VENTILATION MODERN (INDUSTRIAL) KITCHEN VENTILATION SYSTEMS REFERENCES
(INDUSTRIAL) KITCHEN VENTILATION MODERN (INDUSTRIAL) KITCHEN VENTILATION SYSTEMS REFERENCES MODERN SOLUTIONS FOR (INDUSTRIAL) KITCHENS SKV and TPV ventilation and air-conditioning ceilings are the flagships
More informationCommercial Kitchen Ventilation Services. Ventilation Systems. Canopies. Ductwork. Gas Interlock Systems
Commercial Kitchen Ventilation Services ACK offers a full range of commercial kitchen ventilation services including design and planning, manufacture, installation, maintenance and servicing as well as
More informationKOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators
KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S Heat and Energy Recovery Ventilators 2018 AIR HANDLING UNITS 2 CONTENT KOMFORT EC S5B270(-E) 4 KOMFORT EC D5B1(-E) 8 KOMFORT EC S(B)(-E) 12 AIR HANDLING UNITS
More informationSKV, TPV Ventilation and extraction ceilings for industrial kitchens
SKV, Ventilation and extraction ceilings for industrial kitchens Low cost Closed extraction system In-built UV-C filtration Eliminate mold formation Automatic operation control Attractive design Easy maintenance
More informationKOMFORT EC DB Suspended heat recovery air handling units
2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.
More informationKCJ - Closed kitchen ceiling with Capture Jet system KCJ. Closed kitchen ceiling with Capture Jet system
KCJ Closed kitchen ceiling with Capture Jet system 20/KCJ/0000/008/EN Maximum thermal and acoustic comfort Optimal hygiene, air quality, and safety Energy savings Easy cleaning and maintenance Excellent
More informationHalton. Capture Jet technology and service systems. Enabling Wellbeing
Halton Capture Jet technology and service systems Enabling Wellbeing High-Efficiency Kitchen Ventilation Solutions Utilising state-of-the-art technologies and extensive expertise, Halton has focused on
More informationVallox INSTRUCTIONS FOR USE AND MAINTENANCE. Compact. Supply and extract air ventilation with heat recovery
Vallox 1.09.349E 19.5.2009 VALLOX INSTRUCTIONS FOR USE AND MAINTENANCE 70 Compact CODE 3475 Supply and extract air ventilation with heat recovery For blocks of flats, terraced houses and detached houses.
More informationOperation and maintenance instructions
Operation and maintenance instructions TX HomeVex Revision 2014.08.19 Table Of Content 1.0.0 Unit Description... 4 1.1.0 Application... 4 1.2.0 Supply Area... 4 1.3.0 Unit Principle... 4 1.4.0 The Manufacturer's
More informationCeiling swirl diffusers
X X testregistrierung Ceiling swirl diffusers Type Plenum box with damper blade and square diffuser face Horizontal swirling air discharge For comfort zones, with fixed air control blades Circular and
More informationCeiling swirl diffusers
X X testregistrierung Ceiling swirl diffusers Type Plenum box with damper blade (optional) Horizontal swirling air discharge With very low sound power level for comfort zones, with fixed air control blades
More informationCBC - Active Chilled Beam. Halton CBC. Active Chilled Beam
Halton CBC Active Chilled Beam Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling Well suited for spaces with high cooling loads and low humidity load Ideal
More informationTECHNICAL SPECIFICATION
VALLOX-product code: HVAC code: 358500 L 35850 R 79076 L 79077 R SOUND ATTENUATOR (OPTIONAL) IVALLOX 252 WATER OPERATED POST- HEATING UNIT (OPTIONAL) ELECTRICAL POST-HEATING UNIT (OPTIONAL) ELECTRICAL
More informationSwegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION
Swegon CASA R120 Ventilation unit with rotary heat exchanger Ventilation unit for residential houses, multi-storey buidings and holiday cottages under 230 m 2. The unit is equipped with rotary heat exchanger.
More informationAIR PURIFYING SOLUTIONS
AIR PURIFYING SOLUTIONS WWW.DOMAPLASMA.COM ENG Version TECHNOLOGY Domaplasma BV specializes in development and manufacturing of highly efficient air purification systems for over twelve years. With the
More informationCapture at Source FILTERMAX FILTER MODULES WITH AUTOMATIC CLEANING
FILTERMAX FilterMax is a complete filter solution for the entire workshop. Irrespective of whether you extract welding fumes or dust, use extraction arms or permanent built-in capture hoods, FILTER MODULES
More informationCUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams
Integrated chilled beams Key figures Connections: 1x mm, 2x mm Airflow: 5-60 l/s Pressure range: 40 - Pa Size: 293 x 200 mm (WxH) Length: 1192 or 1792 mm Total effect: up to 1200W Cumulus is available
More informationExhaust Duct Design Page 1 of (C)
Exhaust Duct Design Page 1 of 16 2016-10-07 (C) Oven Exhaust Guide Version: R5 Exhaust Duct Design The following section is for your guidance in establishing a design to suit your Exhaust duct design requirements.
More informationSilencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter
VALLOX Product Code: 3158400 L 3158410 R SILENCER (OPTIONAL) INSTRUCTIONS FOR USE AND MAINTENANCE WATER CIRCULATED POST-HEATING UNIT (OPTIONAL) ELECTRIC POST-HEATING UNIT (OPTIONAL)) PREHEATER (OPTIONAL)
More informationDown flow clean air cabinet Star of the Universe. Fortuna
Down flow clean air cabinet Star of the Universe Fortuna Comfort with Protection Operator comfort is of the highest importance and is a high priority for us. The operator is more comfortable and more relaxed,
More informationMEGA YACHTS CRUISE SHIPS CARGO FERRIES OIL RIGS
MEGA YACHTS CRUISE SHIPS CARGO FERRIES OIL RIGS GB The stringent and robust standards applicable to ventilation in the marine business are fundamental to the quality assurance of the tailor made Vianen
More informationIsland Extractor. Instructions & Installation LAM
Island Extractor LAM2850 Instructions & Installation www.howdens.com/appliance-registration See back page for product serial number Dear Customer, Congratulations on your choice of domestic appliance.
More informationMAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY
MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY Product Overview www.orcaenergy.eu MAXI Device for heat recovery MAXI is designed to provide permanent controlled air exchange by means of mechanical ventilation
More informationAir distribution systems. Opticlean OC-Q...
Air distribution systems OC-Q... DS 136 E 06.013 Preliminary remarks, mode of operation and construction design Preliminary remarks KRANTZ KOMPONENTEN has developed the OC-Q in order to combine in a single
More informationFUME EXTRACT STRATEGY STATEMENT
FUME EXTRACT STRATEGY STATEMENT : New Islington Free School No: 7/4781 The site is located in central Manchester on an area of disused land adjacent to the Rochdale canal. The site forms a roughly rectangular
More informationFRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %
FRESHBOX 100 Single-room heat recovery unit Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 CONTENTS FRESHBOX 100 FEATURES 3 DESIGN 4 OPERATING PRINCIPLE 6 CONTROL 6 APPLICATION
More informationBreathe Fresh Air at Home
Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans Breathe Fresh Air at Home Residential Ventilation 2 Category name / Registername
More informationHomepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD
Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD Type ADD FOR THE CREATIVE DESIGN OF CEILINGS IN COMFORT ZONES, WITH FIXED AIR CONTROL BLADES
More informationCONDOR. Supply air ceiling QUICK FACTS
Supply air ceiling QUICK FACTS 00% flexible spread pattern High induction rate Can be cleaned Diffuser modules 595 x 595 mm Available in alternative colours VariZon air distribution system A I R F L O
More informationORT6WXA ORT9WXA Slide-out Rangehoods
Instructions for the Use and Care and Installation of ORT6WXA ORT9WXA Slide-out Rangehoods CONTENT 1. GENERAL 2. SAFETY PRECAUTION 3.. WARNING!! 4.. INSTALLATION INSTRUCTIONS 5.. ATTENTION 6.OPERATION
More informationType TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES
Homepage > Products > Air Diffusers > Ceiling diffusers > Ceiling swirl diffusers > Type TDF-SilentAIR Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES
More informationCHILLED BEAM CASSETTE IQ STAR LYRA
CHILLED BEAM CASSETTE IQ STAR LYRA TECHNICAL CATALOGUE 2 IQ Star LYRA Chilled beam cassette - Technical catalogue IQ STAR LYRA CHILLED BEAM CASSETTE The LYRA chilled beam cassette is a compact chilled
More informationTYPICAL KITCHEN EXTRACT SOLUTION
TYPICAL KITCHEN EXTRACT SOLUTION We have set out below a recommendation for the control of grease, smoke and odour from a fast food outlet using a char grilling process. There are varying degrees of pollution
More informationAir distribution systems. Opticlean OC-Q... DS 4136 E /1
Air distribution systems Opticlean OC-Q... DS 136 E 06.13/1 Preliminary remarks, mode of operation and construction design Preliminary remarks KRANTZ KOMPONENTEN has developed the Opticlean OC-Q in order
More informationResidential Heat Recovery Ventilation. REHVA European Guidebook No 25
Residential Heat Recovery Ventilation REHVA European Guidebook No 25 REHVA European Guidebook No 25 2 Limited to mechanical supply and exhaust ventilation Targeted to engineers, HVAC consultants and contractors
More informationCANOPY RANGEHOOD. instruction manual V3FC60SS & V3FC90SS 12 MONTH WARRANTY
CANOPY RANGEHOOD instruction manual V3FC60SS & V3FC90SS 12 MONTH WARRANTY Contents Guide to the Appliance 2 Caring for the Environment 3 Safety Information and Warnings 4 Installation Instructions 6 Operation
More informationCONTENT: VEX308 Decentralised ventilation VEX308
CONTENT: VEX308 Decentralised ventilation VEX308 VEX308 Decentralised ventilation Download all product data on VEX308 General VEX308 - decentralised ventilation for schools, institutions and offices A
More informationfor a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning
AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS enthalpy membrane in the warm season. This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the
More informationModel: Kair Whole House Ventilator Model Number: KHRVWH2000
Model: Kair Whole House Ventilator Model Number: KHRVWH2000 Installation, Maintenance Instructions and User Guide Unit 6 Chiltonian Industrial Estate 203 Manor Lane, Lee, London. SE12 0TX Tel: 08451 60
More informationPlus Perimeter Aspiration Timer Remote control predisposition
Island Plus Perimeter Aspiration Timer Remote control predisposition Features Installation Finish Controls N. Motors Portata Max Recycling Max Noise Level Min Noise Level Total Absorption Dimensions Lighting
More informationWarnings, Safety Information and Guidance
EN SR700 SRHRV Fan TP600 Single Room Heat Recovery Ventilation Fan Unit SRC Controller TP590 Single Room Heat Recovery Ventilation Controller Unit Product Installation Manual ventilation systems Warnings,
More informationSwegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION
Swegon CASA R85 Ventilation unit with rotary heat exchanger Ventilation unit for residential houses, multi-storey buidings and holiday cottages under 170 m 2. The unit is equipped with rotary heat exchanger.
More informationK Series CK-25 N CK-35 N CK-40 F CK-50 CK-60 F ECO-500 KITCHEN EXTRACTORS. Kitchen extractors CK
KITCHEN EXTRACTORS K Series CK-25 N CK-35 N CK-6 F Range of centrifugal extractors specifically designed for the extraction of moist, grease laden air and fume from under domestic cooker canopies. This
More informationOVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.
OVERVIEW and SYSTEM GUIDE Swegon CASA Residential ventilation for optimal operating economy and the greatest comfort. www.swegon.com Swegon your system supplier Supply air diffuser Vapour barrier for duct
More informationBlancoair Extractor Hoods
Blancoair Extractor Hoods As individual as you are! www.blanco.co.uk Blancoair Creative cooking is an activity that many of us enjoy. There is little doubt that part of the enjoyment of food is the evocative
More informationCARE GUIDANCE. Local Exhaust Ventilation (LEV) Systems for High Temperature Insulation Wool (HTIW) LEVEL 2 RECOMMENDATIONS ON BEST PRACTICE
PUBLICATION: MAY 2012 REVISION: JANUARY 2018 VERSION: 1.2 CARE GUIDANCE RECOMMENDATIONS ON BEST PRACTICE LEVEL 2 Local Exhaust Ventilation (LEV) Systems for High Temperature Insulation Wool (HTIW) 2 LOCAL
More informationKITCHEN EXTRACTORS CK Series Plastic range CK-60 F CK-40 F CK-25 N
KITCHEN EXTRACTORS CK Series Plastic range Centrifugal extractors manufactured from flame retardant plastic V. All extractors are class II insulation fitted with centrifugal impeller and single phase 23V-5Hz
More informationKSR - Backshelf Capture Jet TM hood with or without Side Jets KSR. Backshelf Capture Jet TM hood with or without Side Jets
KSR Backshelf Capture Jet TM hood with or without Side Jets KSR//UK WWW ALLIED MEMBER R LISTED Specially designed for fryers and small grills and to be installed lower compared to traditional hoods Lead
More informationHalton Rex for Vario R6O - Variable air volume chilled beam
Halton Rex for Vario R6O - Variable air volume chilled beam Halton Rex for Vario chilled beam is: Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling Well suited
More informationTUNNEL FANS STANDARD AND HOT SMOKE
TUNNEL FANS STANDARD AND HOT SMOKE NovAx tunnel fans PRODUCT FACTS Product Novenco tunnel fans are produced with either round or rectangular outer dimensions. Both types are made in unidirectional (AUC
More informationFlue Fire Prevention Awareness
Flue Fire Document_R1 Page 1 of 11 2009-03-25 (C) Recommendations Version: 1 Flue Fire Prevention Awareness Introduction Beech Ovens are one of the leading manufacturers of stone hearth ovens in the world.
More informationGUH90 90 cm Canopy Hood
User Manual for your GUH90 90 cm Canopy Hood NOTE: This User Instruction Manual contains important information, including safety & installation points, which will enable you to get the most out of your
More informationORION. Safety Class 2 100% exhaust. ALMOST Rocket Science
LaboGene SCANdinavian by design. ORION ALMOST Rocket Science Safety Class 2 100% exhaust Probably the best Class 2 with 100% exhaust for work with animal handling or high concentrations of organic solvents
More informationThe ventilation appliances
The ventilation appliances Ceiling ventilation 400 series 134 Table ventilations 400 series 138 Island hoods 400 series 144 Wall-mounted hoods 400 series 145 Remote fan units 400 series 148 400 series
More informationFMH Range Hoods. Installation, Operation & Maintenance Instructions
Installation, Operation & Maintenance Instructions Fourneaux de France Ltd Unit 3 Albion Close, Newtown Business Park, Poole Dorset, BH12 3LL Tel 01202-733011 Email info@fdef.co.uk www.fdef.co.uk W1103
More informationour technology Electrostatic Precipitators esp plus maintenance features Electrostatic Precipitators
our technology Electrostatic precipitation consists of three distinct stages. Firstly, grease and smoke particles in the air stream are negatively charged by central cathode needles. This causes the charged
More information60cm Canopy Extractor
60cm Canopy Extractor LAM2300 User & Installation Guide Dear Customer, Congratulations on your choice of domestic appliance which has been designed to give you excellent service. The user manual will help
More informationTechnical Catalog laboratory furniture system
Technical Catalog laboratory furniture system Technical Catalog The new design of our SCALA laboratory furniture program is creating the laboratory of the future. Only when design and functionality effectively
More informationSMOKE CONTROL - NEW DIRECTIONS
SMOKE CONTROL - NEW DIRECTIONS Nuaire provides the total package for smoke control with schemes designed to fully comply with statutory and regulatory requirements. Our team of skilled engineers include
More information1. Oxygen Master 2. Oxygen Sensor 3. Oxygen Refresh Stand-Alone 4. Touch button controls 4. Oxygen Refresh Built-In 5.
77 1 4 3 6 2 5 1. Master 2. Sensor 3. Refresh Stand-Alone 4. Touch button controls 4. Refresh Built-In 5. Exhaust _ System components 1. OXYGEN REFRESH UNITS Built-In Stand-Alone Air freshening unit for
More informationPHOTOCATALYTIC AIR CLEANER
EPCE03-16 PHOTOCATALYTIC AIR CLEANER MC704VM Clean air is essential for a comfortable environment Table of contents 4 01 Antibacterial 5 02 Photocatalytic deodorising power 6 03 Impressive air flow 3 7
More informationEXTRACTOR HOODS.
EXTRACTOR HOODS www.heindl-gmbh.de Lüftungstechnik GmbH HEINDL Lüftungstechnik GmbH Nicolausstraße 5 94447 Plattling Germany info@heindl-gmbh.de Tel. +49 (0) 9931-9 04 53 Fax +49 (0) 9931-9 04 54 Lüftungstechnik
More informationOdour Control - Water Purification Air Sterilisation MAINTENANCE INSTALLATION INFORMATION.
Odour Control - Water Purification Air Sterilisation MAINTENANCE INSTALLATION INFORMATION ABOUT THE PRO3 OZONE GENERATOR PRODUCT INFORMATION The PRO3 Ozone Generator is a high output corona discharge ozone
More informationOthers ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units
PAGE 1/32 Summary This document (_r2) updates the previous one (_r1) issued on Mar 08. Revised items are identified by using: 2 (1 Location). This Advanced Products News introduces the new line-up of KPI-(502~2002)E1E
More informationGlass Canopy Wall-Mount Hood
Glass Canopy Wall-Mount Hood FHWC3060L S 30" Stainless Steel Features Nominal Width 30" Installation Type Wall Mount Style Stainless Steel / Glass Canopy Air Discharge Vertical Air Delivery (CFM) 400 Blower
More informationRWC Issue: F. Description: ARISTON WALL CANOPY Model Numbers: ARCH90BIX. Model may vary slightly from images pictured. All measurements are in mm.
RWC Issue: F Description: ARISTON WALL CANOPY Model Numbers: ARCH90BIX Model may vary slightly from images pictured. All measurements are in mm. 1 Overview Pre-installation Thank you for purchasing a quality
More informationElectrostatic Precipitator
lectrostatic Precipitator Manual Clean & Autowash System the SP solution to grease and smoke pollution... Local Legislation Local Legislation requires increasingly that the amount of grease and smoke in
More informationS ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5
S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE The Quietest Extractors in the World in their Category Lp 26,5 db AXIAL FLOW FANS Series -1-1 16182 6376-2 -3 NEW Installation examples Axial fl
More informationRANGE COOKER HOOD GUIDE
RANGE COOKER HOOD GUIDE CHOOSING THE RIGHT COOKER HOOD FOR YOUR KITCHEN You ve probably spent a lot of time choosing your perfect range cooker, but what about a cooker hood? Take a look through our handy
More informationiq Star LYRA II chilled beam cassette
iq Star LYRA II chilled beam cassette Key features Ventilation Heating and cooling Compact chilled beam Adjustable induction Flow Pattern Control Integrated control In option: Demand Controlled Ventilation,
More informationHalton Rex 600 Basic R6B - Active chilled beam
Halton Rex 600 Basic R6B - Active chilled beam Halton Rex 600 Basic chilled beam is: A base version to the combined cooling, heating, and supply air unit for flush installation within a suspended ceiling.
More informationPRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.
PRODUCT DATA COMBI 300 POLAR BY NILAN Ventilation with passive & active heat recovery Domestic Passive heat recovery Active heat recovery Ventilation < 350 m 3 /h Comfort heating Comfort cooling COMBI
More informationBasic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives
Design Considerations for Commercial Kitchen Ventilation By John A. Clark, P.E., Member ASHRAE Commercial kitchen ventilation (CKV) design must consider everything needed to be coordinated to form a system
More informationBEST PRACTICE RECOMMENDATIONS
Second and Delaware, Kansas City, MO BEST PRACTICE RECOMMENDATIONS PHIUS 1 OUTLINE VENTILATION & COMPONENT REQUIREMENTS UNDER PHIUS+ COMPARISON TO OTHER VENTILATION STANDARDS: ASHRAE 62.2 2016 ERV/HRV
More informationIntrCooll. Cool large buildings at 80% lower running costs
IntrCooll Cool large buildings at 80% lower running costs IntrCooll INDIRECT/DIRECT ADIABATIC COOLING COOLING CAPACITY UP TO 134 kw (38 TR) UP TO 116% WET-BULB EFFICIENCY EER UP TO 44 (150 BTU/Wh) Introduction
More informationEco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:
Eco Active Heat Recovery Penthouse Turret W: www.gdl.co.uk T: 01457 861538 Heat Recovery Penthouse Turret The HRPT provides ventilation into spaces all year round. The unit provides 100% fresh air whilst
More informationWORKSHOP VENTILATION- PSYCHROMETRICS-AHU
Alkis Triantafyllopoulos Mechanical Engineer Member TEE, MASHRAE a.trianta@gmail.com WORKSHOP VENTILATION- PSYCHROMETRICS-AHU Based on ASHRAE 62 Purpose Set minimum Outdoor Air ventilation Rates Air Quality
More information60cm Chimney Extractor
60cm Chimney Extractor LAM2401 HJA2480 User & Installation Guide Contents Page Environmental note 3 IMPORTANT SAFETY INFORMATION 4 6 Specifications of your extractor 7 8 Dimensions 7 Specifications 7-8
More informationThe ventilation appliances
The ventilation appliances Ceiling ventilation 400 series 186 Table ventilations 400 series 190 Downdraft ventilation 400 series 196 Island hoods 400 series 210 Wall-mounted hoods 400 series 211 Remote
More informationMODEL: BV400 Part No:
MODEL: BV400 Part No: 90000312 Mechanical Ventilation with Heat Recovery Installation and Commissioning Manual PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT INDEX 1. Introduction... 3 2. General Instructions...
More informationFlexit air handling units UNI 2, 3 og 4
Flexit handling units UNI 2, 3 og 4 energy efficient ventilation for a healthy indoor environment FOR A HEALTHY INDOOR ENVIRONMENT Energy-efficient ventilation Flexit UNI 2, 3 and 4 The handling units
More informationREQUIREMENTS FOR HOOD PLANS
DEPARTMENT OF PUBLIC HEALTH Division of Environmental Health REQUIREMENTS FOR HOOD PLANS Submit one (1) set of plans drawn to scale of at least ¼-inch per foot. Plans shall conform to applicable California
More informationKLIMA Active Chilled Beams
KLIMA 2 600 Active Chilled Beams Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Section example Guide specifications 13 1 Introduction
More informationALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector
ALUMINUM REPAIR CERTIFICATION EQUIPMENT Eliminate hazardous aluminum dust with a Eurovac system BODY REPAIR EQUIPMENT OPTIONS Product Description When repairing an aluminum structured vehicle, it is essential
More informationOPERATING & MAINTENANCE INSTRUCTIONS FOR EXTRACTION SYSTEMS
OPERATING & MAINTENANCE INSTRUCTIONS FOR EXTRACTION SYSTEMS EXTRACTION SYSTEMS OPERATION AND MAINTENANCE See table 1 (below) for cleaning frequencies. 1) EXTRACTION CANOPY CLEANING Generally the extraction
More informationInstructions for the Use and Care and Installation of ORW6XA ORW9XA. Wall Canopy Rangehoods
Instructions for the Use and Care and Installation of ORW6XA ORW9XA Wall Canopy Rangehoods CONTENTS 1 Notice 2 Features 3 Installation 4 Notice of installation 5 Safety Warning 6 Use Instructions 7 Maintenance
More informationGUH52SD 52 cm GUH75 75 cm Canopy Hood
User Manual for your GUH52SD 52 cm GUH75 75 cm Canopy Hood NOTE: This User Instruction Manual contains important information, including safety & installation points, which will enable you to get the most
More informationInstructions for the Use and Care and Installation of ORC97G ORC98G. Glass Canopy Rangehoods
Instructions for the Use and Care and Installation of ORC97G ORC98G Glass Canopy Rangehoods CONTENTS 1 Notice 2 Features 3 Installation 4 Notice of installation 5 Safety Warning 6 Use Instructions 7 Maintenance
More informationSwegon CASA R120. Instructions for installation, operation and maintenance. R120_h_EN-m
Swegon CASA R120 Instructions for installation, operation and maintenance R120_h_EN-m Content Instructions for Use For the user Important information... 3 Control from a Premium control panel... 4 Control
More informationCeiling diffusers. Type DLQL
X X testregistrierung Type Horizontal one-way air discharge Horizontal two-way air discharge Horizontal four-way air discharge Horizontal duct connection For horizontal one-way to four-way air discharge,
More information