TURBO HOODS. Product Brochure

Size: px
Start display at page:

Download "TURBO HOODS. Product Brochure"

Transcription

1 TURBO HOODS Product Brochure

2 TABLE OF CONTENTS FUNCTIONING PRINCIPLE PRODUCT CODE... 0 PRODUCT STRUCTURE TURBOSWING GREASE FILTER EXHAUST AIR SUPPLY AIR LIGHTS... 0 DIENSIONS... ELECTRICAL AND AUTOATION PLANNING... All rights reserved Turbo Hoods

3 TURBO HOODS helping professionals to enjoy their work and give their best. Turbo hoods have been developed for professional kitchens requiring energy efficiency and versatility, as well as a safe and comfortable kitchen climate for the staff. Turbo hoods can be used to utilize variable air flow energy saving systems and kitchen exhaust air energy by heat recovery. The excellent filtration efficiency of Turbo hoods keeps the ventilation ducts clean, even from the smallest particles of contamination and gaseous grease.

4 FUNCTIONING PRINCIPLE SUPPLY AIR HOOD JSI-R-TURBO Dirty air rises due to temperature differences against the ceiling of the hood. 4 Dirty air is exhausted immediately through the units. Since s air intake is placed close to the ceiling, the warmest dirty air is always exhausted through it. Ventilation efficiency is of the highest rate because of the correct position of with respect to the kitchen equipment. When the separator plate of rotates, the grease and impurities are separated into the collecting vessel. Direction air prevents leakage and directs steam and impurities towards. 4 Fresh and draught-free supply air is brought into the kitchen through the supply air columns placed on the outside walls of the supply air hood. This results in very effective ventilation in the kitchen. Clean air is exhausted into the ducts. JLI-R-TURBO 4 Turbo Hoods

5 PRODUCT CODE JSI=Supply air hood (incl. supply air) JLI=Exhaust air hood Wall material R=Stainless steel AISI 04 S=Laminated glass Turbo= Length Width Height Number and size of the supply air connections Number and size of the exhaust air connections Supply air flow, l/s Exhaust air flow, l/s ACCESSORIES CB=Covering boards SC=SwingControl VK=Covering box FP=Ansul R0 Fire Suppression System JSI - R- Turbo x 00 x 40-4 x 0 - x l/s - 0 l/s - CB - SC - VK - FP Turbo Hoods

6 PRODUCT STRUCTURE TURBO HOODS grease filter Exhaust air connection and damper plates Lights 4 Supply air unit with removable front panel Supply air connection and damper unit 4 6 Turbo Hoods

7 TURBOSWING GREASE FILTER Collar saddle Balancing dampers Limit switch 4 Signal light Dome fixing EC motor Separation plate Airflow measuring tap Collection basin Tap 0 An innovative solution for demanding grease filtration in professional kitchens, based on rotary motion, mechanically separates fat particles even as small as μm. The rapid rotating separating disc separates even small particles and throws them at a high speed to the outer edges of the separation chamber, from which grease and other impurities flow into the collection basin. Liquid grease and impurities separated by are removed with the opening of the tap, which is made depending on the kitchen load weekly or less frequently. is very well suited for energy saving applications with heat recovery from the kitchen and/or changing air flows. s filter efficiency remains very high even at low airflows. is a 99.8 % tight filter solution. Turbo Hoods 7

8 EXHAUST AIR TURBOSWING GREASE FILTER Separation rate of 00 Separation rate, % Particle size (µm) 00 rpm 70 rpm Recommended exhaust flow/spigot Spigot size ø Exhaust flow Pressure loss mm l/s m/h Pa Pressure loss and sound data 70 rpm 00 rpm 0 Adjustment plate half closed open 0 Adjustment plate half closed open Pressure Ps (Pa) db(a ) =8 db(a ) =4 db(a ) =0 Ps (Pa) Pressure db(a ) =44 db(a ) =40 db(a ) = l/s l/s m /h m /h Sound pressure level 4 db (A) with room suppression. atch 0 m²-sab total absorption. Sound pressure level 4 db (A) with room suppression. atch 0 m²-sab total absorption. Sound power level, Lw in each octave band is computed by adding the corresponding factor, Kok to the sound power level LpA. Lw= LpA+Kok Factor, Kok Hz Kok tol. ± ± ± ± ± ±4 8 Turbo Hoods

9 SUPPLY AIR SUPPLY AIR HOOD JSI-R-TURBO Jeven supply air columns deliver a controlled and flexible distribution of the supply air. It is possible to wash the supply air columns in a dishwasher and the inside of the supply air chambers is easy to clean. These columns allow individual adjustment of air patterns and airflows, which means better indoor climate for the kitchen staff. The canopies are supplied from the factory with suitable air flow rates for a pressure level of - Pa. The supply air blow direction can be aligned up or down by turning the horizontal air control plates inside the supply air units. Unidirectional thrown pattern Displacement thrown pattern Bidirectional thrown pattern The amount of supply air/supply air unit Hood height Supply air unit width, B mm 00 mm 00 mm l/s l/s 00-0 l/s Supply air unit, damper open Sound attenuation, db Hood height Hz Spigot mm ø mm ø ø Pressure loss, sound data & throw lenght/supply air unit Pressure Ps (Pa) Spigot ø60 mm. Unit width 00 mm. Hood height 40 mm. easurement after 90 curve. Damper half closed open l/s db(a ) = 4 db(a ) = 40 db(a ) = db(a ) = 0 Pressure Ps (Pa) Spigot ø 0 mm. Unit width 00 mm. Hood height 40 mm. easurement after 90 curve. Damper half closed open l/s db(a ) = 4 db(a ) = 40 db(a ) = db(a ) = m /h , 0,8,4 m /h L0, (m) Turbo Hoods 9

10 SUPPLY AIR SUPPLY AIR HOOD JSI-R-TURBO Pressure loss, sound data & throw length/supply air unit Spigot ø 00 mm. Unit width 00 mm. Hood height 0 mm. easurement after 90 curve. Pressure Ps (Pa) Damper half closed , 0,8,4 open db(a ) = 4 db(a ) = 40 db(a ) = db(a ) = 0 l/s m /h L0, (m) The sound power level (Lw) in each octave band is computed by adding the corresponding factor Kok to the sound pressure level (LpA), as in Lw= LpA+Kok Spigot ø60 Hz Kok tol. ± ± ± ± ± ±4 Spigot ø00 Hz Kok tol. ±6 ±4 ± ± ± ± Spigot ø0 Hz Kok tol. ± ± ± ± ± ±4 LIGHTS By default, every hood module comes with a light fixture. The light fixture has a cable which should be connected to a junction box with a cable lock. The lighting solution is approved by an electric inspection centre. The connecting cable must be positioned in such a way that it is not exposed to mechanical or thermal stress. IP 66 embedded LED lamp Colour temperature 840 (Cool White) m cable, type EKK x, 0 Turbo Hoods

11 DIENSIONS TURBO HOODS Wall hood width A odule W x6w K (module) B length odule J J W x6w C ød Turbo hoods are made on a project-by-project basis, according to the planned dimensions. Hoods length and width can be chosen freely. A and B dimensions shall be at least 00 mm. J-J width 7 F height Island type hood width A W x8w W G x8w W W (module) length W W L L x8w W x8w W C E L-L width 00 height 7 Size and placement of the supply air units supply air hood JSI-R-Turbo Hood height C F ø D G E min K min Turbo Hoods

12 POSITIONING The size of the canopy is determined by the size of the kitchen equipment. The overhang depends on the type of equipment and the distance between the hood and the equipment. For this type of equipment, the overhang should be at least 00 mm. The typical distance between the hood side and the floor is mm. If the equipment has any doors that open upwards, make sure there is enough distance to the canopy X >0. * X >400 Oven ELECTRICAL AND AUTOATION PLANNING The HPAC designer records in the plans the types and locations of the products to be wired. The electrical designer designates to the plans the location of the safety switch (compulsory), the necessary appliance sockets, and the required wiring from group switchboard or kitchen switch to the safety switch. Connection box 0VAC m 0VAC 0VAC The Automation designer records, in the plans, that the running time of the will match the running time of the exhaust fan. 0VAC m A safety switch is compulsory and it should be situated close to the hood and in a visible place in the kitchen. Connection box Appliance Safety switch socket for possible branches The safety switch, appliance sockets and the cables marked with the dotted line are not included in the Jeven delivery. Turbo Hoods

13 Please feel free to contact us if you require any further information jeven.fi

UV-TURBO HOODS. Product Brochure

UV-TURBO HOODS. Product Brochure UV-TURBO HOODS Product Brochure TABLE OF CONTENTS FUNCTIONING PRINCIPLE... 0 PRODUCT CODE... 0 PRODUCT STRUCTURE... 06 UV-TURBO GREASE FILTER... 07 EXHAUST AIR... 08 SUPPLY AIR... 09 LIGHTS... 0 DIENSIONS...

More information

JSI-UV canopy - Ultraviolet and cyclonic filters, and supply air JSI-UV hoods Product Description Lights and filters

JSI-UV canopy - Ultraviolet and cyclonic filters, and supply air JSI-UV hoods Product Description Lights and filters JSI-UV canopy - Ultraviolet and cyclonic filters, and supply air Product Description The Jeven JSI-UV canopy has been designed for kitchens where a comfortable, productive and healthy indoor climate is

More information

KOMFORT EC DB Suspended heat recovery air handling units

KOMFORT EC DB Suspended heat recovery air handling units 2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.

More information

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY Product Overview www.orcaenergy.eu MAXI Device for heat recovery MAXI is designed to provide permanent controlled air exchange by means of mechanical ventilation

More information

KVF - Capture Jet canopy with Supply Air and Side-Jet Technology KVF. Capture Jet Canopy with Supply Air and Side-Jet Technology

KVF - Capture Jet canopy with Supply Air and Side-Jet Technology KVF. Capture Jet Canopy with Supply Air and Side-Jet Technology KVF Capture Jet Canopy with Supply Air and Side-Jet Technology ALLIED EBER R LISTED HACCP* certified (PE-567-H01I). 30 to 40% reduction in exhaust airflow rates thanks to the Capture Jet technology. High-efficiency

More information

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 % Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed

More information

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S Heat and Energy Recovery Ventilators 2018 AIR HANDLING UNITS 2 CONTENT KOMFORT EC S5B270(-E) 4 KOMFORT EC D5B1(-E) 8 KOMFORT EC S(B)(-E) 12 AIR HANDLING UNITS

More information

Supply air hood JSI-UV Installation-, adjustment and user guide

Supply air hood JSI-UV Installation-, adjustment and user guide Supply air hood JSI-UV Installation-, adjustment and user guide PAGE Table of Contents Installation of hanging brackets Fixture points and connecting the hood modules 4 Installation of glasses 5 Light

More information

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS enthalpy membrane in the warm season. This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the

More information

JSKI Installation-, adjustment and user guide

JSKI Installation-, adjustment and user guide JSKI Installation-, adjustment and user guide PAGE Table of Contents Installation of hanging brackets Fixture points and connecting the hood modules 4 Light fittings 5 Installation of covering boards 6

More information

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery. PRODUCT DATA COMBI 300 POLAR BY NILAN Ventilation with passive & active heat recovery Domestic Passive heat recovery Active heat recovery Ventilation < 350 m 3 /h Comfort heating Comfort cooling COMBI

More information

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams Integrated chilled beams Key figures Connections: 1x mm, 2x mm Airflow: 5-60 l/s Pressure range: 40 - Pa Size: 293 x 200 mm (WxH) Length: 1192 or 1792 mm Total effect: up to 1200W Cumulus is available

More information

CHILLED BEAM CASSETTE IQ STAR LYRA

CHILLED BEAM CASSETTE IQ STAR LYRA CHILLED BEAM CASSETTE IQ STAR LYRA TECHNICAL CATALOGUE 2 IQ Star LYRA Chilled beam cassette - Technical catalogue IQ STAR LYRA CHILLED BEAM CASSETTE The LYRA chilled beam cassette is a compact chilled

More information

Bevent Rasch. FIDm. - Fire /11/2018

Bevent Rasch. FIDm. - Fire /11/2018 Bevent Rasch - Fire - FIDm 27/11/2018 Self-acting back draught damper for combustion gases, with actuator for boosting or control and metering socket for commissioning Sizes from Ø 100 to 20 mm Available

More information

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 Single-room heat recovery unit Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 CONTENTS FRESHBOX 100 FEATURES 3 DESIGN 4 OPERATING PRINCIPLE 6 CONTROL 6 APPLICATION

More information

Bevent Rasch. FIDs. - Fire /05/18

Bevent Rasch. FIDs. - Fire /05/18 Bevent Rasch - - FIDs /0/8 Self-acting back draught damper for combustion gases, without commissioning function Sizes Ø 80 to 60 mm For mounting on manifold distribution box BRSL www.bevent-rasch.com Product

More information

iq Star LYRA II chilled beam cassette

iq Star LYRA II chilled beam cassette iq Star LYRA II chilled beam cassette Key features Ventilation Heating and cooling Compact chilled beam Adjustable induction Flow Pattern Control Integrated control In option: Demand Controlled Ventilation,

More information

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation

More information

Swegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION

Swegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION Swegon CASA R85 Ventilation unit with rotary heat exchanger Ventilation unit for residential houses, multi-storey buidings and holiday cottages under 170 m 2. The unit is equipped with rotary heat exchanger.

More information

Excellent Ventilation for Professional Kitchens

Excellent Ventilation for Professional Kitchens www.jeven.com Excellent Ventilation for Professional Kitchens www.jeven.com Everyone Loves Good Food... but in order for the food to be good, not only do you need to know how to make it, but you also need

More information

Series VENTS VUT R WH ЕС

Series VENTS VUT R WH ЕС AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS EH ЕС Series VENTS WH ЕС Air handling units with the air capacity up to 1500 m 3 /h in soundand heat-insulated casing with integrated electric heater.

More information

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing Field of application Description Advantages Range Technical details Installation Remote controls Servicing Remote control ErP * ** Conpliance compliance. ErP ready. Advantages Reversible connections. Ventilation

More information

Capture at Source FILTERMAX FILTER MODULES WITH AUTOMATIC CLEANING

Capture at Source FILTERMAX FILTER MODULES WITH AUTOMATIC CLEANING FILTERMAX FilterMax is a complete filter solution for the entire workshop. Irrespective of whether you extract welding fumes or dust, use extraction arms or permanent built-in capture hoods, FILTER MODULES

More information

CONDOR. Supply air ceiling QUICK FACTS

CONDOR. Supply air ceiling QUICK FACTS Supply air ceiling QUICK FACTS 00% flexible spread pattern High induction rate Can be cleaned Diffuser modules 595 x 595 mm Available in alternative colours VariZon air distribution system A I R F L O

More information

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h PRODUCT DATA COMFORT 450 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 450 m 3 /h COMFORT 450 Product description The Comfort 450 is an energy-efficient ventilation

More information

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h PRODUCT DATA COMFORT 300 TOP BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 325 m 3 /h COMFORT 300 TOP Product description The Comfort 300 Top is an energy-efficient

More information

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 800 m /h COMFORT 00 Product description The Comfort 00 is an energy-efficient ventilation

More information

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION Swegon CASA R120 Ventilation unit with rotary heat exchanger Ventilation unit for residential houses, multi-storey buidings and holiday cottages under 230 m 2. The unit is equipped with rotary heat exchanger.

More information

NORDcanopy Kitchen ventilation

NORDcanopy Kitchen ventilation NORcanopy Kitchen ventilation Contents General NORcanopy KS Kitchen hood for supply and exhaust air KV Kitchen hood for exhaust air KTS Kitchen hood for supply air KTV Kitchen hood KVM Exhaust air module

More information

Orion-Opus LØV-R with Sirius

Orion-Opus LØV-R with Sirius GB0653 09.17 Orion-Opus LØV-R with Sirius VAV box for supply diffuser Unique damper function Extensive working range Belimo MP-Bus Modbus LONWORKS Belimo KNX TROX Trox Norge AS PO Box 100 NO-2712 Brandbu

More information

Flexit air handling units UNI 2, 3 og 4

Flexit air handling units UNI 2, 3 og 4 Flexit handling units UNI 2, 3 og 4 energy efficient ventilation for a healthy indoor environment FOR A HEALTHY INDOOR ENVIRONMENT Energy-efficient ventilation Flexit UNI 2, 3 and 4 The handling units

More information

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam Halton CBC Active Chilled Beam Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling Well suited for spaces with high cooling loads and low humidity load Ideal

More information

Heat recovery unit RDKS

Heat recovery unit RDKS Heat recovery unit RDKS Heat recovery unit RDAS is based on our RDAR unit and develops this further. The unit has a rotary heat exchanger with stepless speed control. This allows for very precise temperature

More information

HOTEL CHILLED BEAM IQ STAR SILENCIA

HOTEL CHILLED BEAM IQ STAR SILENCIA HOTEL CHILLED BEAM IQ STAR SILENCIA TECHNICAL CATALOGUE 2 IQ Star Silencia Hotel Chilled beam - Technical catalogue IQ STAR SILENCIA HOTEL CHILLED BEAM Silencia unit is designed for use in hotel bedrooms,

More information

KCJ - Closed kitchen ceiling with Capture Jet system KCJ. Closed kitchen ceiling with Capture Jet system

KCJ - Closed kitchen ceiling with Capture Jet system KCJ. Closed kitchen ceiling with Capture Jet system KCJ Closed kitchen ceiling with Capture Jet system 20/KCJ/0000/008/EN Maximum thermal and acoustic comfort Optimal hygiene, air quality, and safety Energy savings Easy cleaning and maintenance Excellent

More information

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

WORLD VENTILATION LEADER   SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS WORLD VENTILATION LEADER IO EM.COM SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS VENTS reserves the rights to modify any of its products featuers, designs, components and specifications

More information

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS Compact heat recovery unit with high efficiency counter-flow heat exchanger in 5 sizes from 580 m3/h to 3.650 m3/h. The casing is made from aluminium profile

More information

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery. PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 300 m 3 /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION VALLOX-product code: HVAC code: 358500 L 35850 R 79076 L 79077 R SOUND ATTENUATOR (OPTIONAL) IVALLOX 252 WATER OPERATED POST- HEATING UNIT (OPTIONAL) ELECTRICAL POST-HEATING UNIT (OPTIONAL) ELECTRICAL

More information

Bevent Rasch RABC-VAV. - Fire /03/2018

Bevent Rasch RABC-VAV. - Fire /03/2018 Bevent Rasch - Fire - RABC-VAV 26/03/2018 Fire damper and VAV-damper combined RABC-VAV Fire resistance class E60 Sizes from 100 mm to 630 mm Prefitted safety actuator 24V Installation in ducts Available

More information

Flexit air handling units C2 and UNI 2, 3,4

Flexit air handling units C2 and UNI 2, 3,4 Flexit handling units C2 and UNI 2, 3,4 energy efficient ventilation for a healthy indoor environment A FOR A HEALTHY INDOOR ENVIRONMENT Energy-efficient ventilation Flexit C2 and UNI 2, 3, 4 The handling

More information

iq Star LYRA II chilled beam cassette

iq Star LYRA II chilled beam cassette Key features The LYRA II cassette is an active chilled beam for ventilation, cooling and heating. This diffusion system offers high flexibility thanks to the combination of Flow Pattern Control, Coanda

More information

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h PRODUCT DATA COMFORT 5000 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 5300 m 3 /h COMFORT 5000 The Comfort 5000 is a ventilation unit suitable for central

More information

CONTENT: VEX308 Decentralised ventilation VEX308

CONTENT: VEX308 Decentralised ventilation VEX308 CONTENT: VEX308 Decentralised ventilation VEX308 VEX308 Decentralised ventilation Download all product data on VEX308 General VEX308 - decentralised ventilation for schools, institutions and offices A

More information

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25 Residential Heat Recovery Ventilation REHVA European Guidebook No 25 REHVA European Guidebook No 25 2 Limited to mechanical supply and exhaust ventilation Targeted to engineers, HVAC consultants and contractors

More information

KITCHEN EXTRACTORS CK Series Plastic range CK-60 F CK-40 F CK-25 N

KITCHEN EXTRACTORS CK Series Plastic range CK-60 F CK-40 F CK-25 N KITCHEN EXTRACTORS CK Series Plastic range Centrifugal extractors manufactured from flame retardant plastic V. All extractors are class II insulation fitted with centrifugal impeller and single phase 23V-5Hz

More information

VEX250H with rotary heat exchanger and EXact control system

VEX250H with rotary heat exchanger and EXact control system 3003433-2014-04-11 VEX250_EXact VEX250H with rotary heat exchanger and EXact control system Unit supplied with (factory fitted): Compact filter FP Filter bag FB Trim damper and blowout zone,tb250 The following

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Plenum box with damper blade and square diffuser face Horizontal swirling air discharge For comfort zones, with fixed air control blades Circular and

More information

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h PRODUCT DATA COMFORT 302 TOP BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 345 m 3 /h COMFORT 302 TOP Product description The Comfort 302 Top is an energy efficient

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Plenum box with damper blade (optional) Horizontal swirling air discharge With very low sound power level for comfort zones, with fixed air control blades

More information

Air to Air Heat Exchanger

Air to Air Heat Exchanger Air to Air Heat Exchanger VN-M1HE / VN-M2HE VN-M3HE / VN-MHE VN-M6HE / VN-M8HE VN-M1HE VN-M1HE VN-M2HE Air to Air Heat Exchanger MMD VN2HEXE MMD VN82HEXE MMD VN12HEXE with DX-coil Type CONTENTS 1. Specifications

More information

Small Room Heat Recovery Ventilation

Small Room Heat Recovery Ventilation Small Room Heat Recovery Ventilation Ideal for smaller spaces that would benefit from heat recovery, such as staff rooms or offices Version 3.1 2 Breathing Buildings Small Room Heat Recovery 3 Small Room

More information

TopVent Design Handbook

TopVent Design Handbook TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit

More information

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam Halton CBH Active Chilled Beam Combined cooling, heating and supply air unit for exposed wall installation Well suited for hotel guest rooms with high requirements for thermal comfort and room acoustics

More information

Heat and energy recovery ventilators

Heat and energy recovery ventilators Description is recommended for use in residential houses with max. area of 200m2. The most important key features of : Heat recovery up to 95% according to EN 308 - TUV SUD Plastic counterflow heat exchanger

More information

Auxiliary Equipment and Accessories

Auxiliary Equipment and Accessories http://www.ventilation-alnor.co.uk/index/products_en/heat-recovery-%e2%80%93-air-handling-units/ Description is recommended for use in residential houses with max. area of 200m2. The most important key

More information

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure COMPACT AIR HANDLING UNIT CompAir RW Technical Brochure Version 1.4 January 2013 INDEX: 1 GENERAL... 4 2 COMPAIR RW 2000... 8 2.1 Technical specification... 8 2.2 External static pressure/air volume diagram...

More information

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam Halton CHH Active Chilled Beam Combined cooling, heating, and supply air unit for suspended ceiling / bulkhead installation Excellent suitability for hotel guest rooms with high requirements for thermal

More information

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling. PRODUCT DATA VPL 15 TOP M2 BY NILAN Ventilation & active heat recovery Domestic Active heat recovery Ventilation < 400 m 3 /h Comfort heating Comfort cooling VPL 15 TOP M2 Product description VPL 15 Top

More information

VEX100 series Air handling units with cross-flow heat exchanger

VEX100 series Air handling units with cross-flow heat exchanger Product information - Version 6 VEX100 series Air handling units with cross-flow heat exchanger VEX140: 400-2200 m 3 /h VEX150: 700-3600 m 3 /h VEX160: 1100-5000 m 3 /h VEX170: 1400-8400 m 3 /h Contents

More information

Domestic & Commercial Fans

Domestic & Commercial Fans Max. airflow l/s Axial Fan Centrifugal Fan Speed Controllable Reversible Airflow Page Number BF IF CF CBF BF 64 * 16 IF 64 * 16 EAF LV 23 * 169 ECF LV 31 * 169 CF 25 * 170 CBF 31 * 170 RVF 0 * * 171 BRAVO

More information

SINGLE-ROOM VENTILATION. for schools and public spaces

SINGLE-ROOM VENTILATION. for schools and public spaces SINGLE-ROOM VENTILATION for schools and public spaces Industrial and commercial ventilation (Catalogue no. 1) Industrial and commercial ventilation components - fans for round and rectangular ducts, sound-insulated,

More information

Bevent Rasch BSKC6. - Fire /06/17

Bevent Rasch BSKC6. - Fire /06/17 Bevent Rasch - Fire - BSKC6 19/06/17 Fire resistance class EI60/EI60S Sizes from 100 mm to 630 mm Prefitted safety actuator 24V or 230V Low weight Easy installation CE-marked building product according

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

PRODUCT DATA VPL 28 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

PRODUCT DATA VPL 28 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling. PRODUCT DATA VPL 28 BY NILAN Ventilation & active heat recovery Domestic Active heat recovery Ventilation < 1000 m 3 /h Comfort heating Comfort cooling VPL 28 Product description VPL 28 is an energy-efficient

More information

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2 AIR HANDLING UNITS DESIGN System INFORMATION No off Access Handing Viewed in direction of supply air Finish / Colour Duct Connections Height: Width Velocity: Design Airflow (m3/s) Supply Fan Ability Supply

More information

Low Wall Back Shelf Exhaust Canopy

Low Wall Back Shelf Exhaust Canopy ITEM NO. 710 Powerline Road Suite H Deerfield Beach, FL 33442 (954) 570-9860 (800) 322-8730 FAX (954) 570-9865 Low Wall Back Shelf Exhaust Canopy Model LW APPLICATION Wall mounted canopy style ventilator

More information

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini... Contents How to choose Recovery Ventilation type?............................................3 How do HRV, ERV and TRV Systems work?............................................4 Types of installations..............................................................5

More information

Orion-LØV LØV-R with Sirius

Orion-LØV LØV-R with Sirius GB0652 01.18 Orion-LØV LØV-R with Sirius VAV box for supply diffuser Unique damper function Extensive working range Belimo MP-Bus Modbus LONWORKS Belimo KNX TROX Auranor Norge AS PO Box 100 NO-2712 Brandbu

More information

VEX280H with rotary heat exchanger and EXact control system

VEX280H with rotary heat exchanger and EXact control system 3003206-2014-04-15 VEX280_EXact VEX280H with rotary heat exchanger and EXact control system Unit supplied with (factory fitted): VEX280-1 VEX280-2 FP compact filter FB filter bag TB280 trim damper and

More information

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING.

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING. EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING. EASYAIR THE EASY WAY OF AIR HANDLING Independently VDI 6022 tested and certified down to the last detail The new generation of EASYAIR compact devices

More information

Commercial Kitchen Ventilation Services. Ventilation Systems. Canopies. Ductwork. Gas Interlock Systems

Commercial Kitchen Ventilation Services. Ventilation Systems. Canopies. Ductwork. Gas Interlock Systems Commercial Kitchen Ventilation Services ACK offers a full range of commercial kitchen ventilation services including design and planning, manufacture, installation, maintenance and servicing as well as

More information

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL CONTENT 3 Introduction 3 General 3 Safety rules 3 Storage and transportation rules 3 Manufacturer s warranty 4 Fan design 4 Delivery set 5 Technical data

More information

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR Central ventilation system ZLS Central ventilation system ZLS-DV EC according. ZLS-DV EC is the ideal central ventilation system in multi-storey construction according. EXTRACT AIR OUTSIDE AIR FIRE PROTECTION

More information

G Installation manual Solitude - dmev unit

G Installation manual Solitude - dmev unit G G Installation manual Solitude - dmev unit Read this manual carefully before using the product and keep it in a safe place for reference. This product was constructed up to standard and in compliance

More information

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems Technical Bulletin BT13F002GB-04 ELFODuct MP New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems ELFODUCT MP 15-71 SERIES SERIES RECOMMENDED FOR

More information

ENERVEX RSV CHIMNEY FAN

ENERVEX RSV CHIMNEY FAN ENERVEX RSV 200-450 CHIMNEY FAN 3000775 06.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238 F: 770.587.4731

More information

G Installation Manual (installer & user) QR180MBP Heat Recovery Ventilation Unit

G Installation Manual (installer & user) QR180MBP Heat Recovery Ventilation Unit G Installation Manual (installer & user) QR180MBP Heat Recovery Ventilation Unit Read this manual carefully before using the product and keep it in a safe place for reference as necessary. This product

More information

UVF - Capture Jet canopy combined with Capture Ray TM technology and low velocity supply air UVF

UVF - Capture Jet canopy combined with Capture Ray TM technology and low velocity supply air UVF UVF Capture Jet canopy combined with Capture Ray TM technology and low velocity supply ALLIED MEMBER R LISTED HACCP* certified (PE-567-HM01I). to % reduction in exhaust airflow rates thanks to the Capture

More information

InspirAIR Home RESIDENTIAL AIR PURIFICATION

InspirAIR Home RESIDENTIAL AIR PURIFICATION InspirAIR Home InspirAIR Home The fi rst Aldes connected solution for centralised air purifi cation which beats to the rhythm of your life. RESIDENTIAL AIR PURIFICATION CONTENTS Presentation........................................................

More information

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater SUPPLY UNITS Series VENTS PA E Series VENTS PA W A13 control panel A13 control panel Suspended air supply units with the air capacity up to 3350 m 3 /h in the sound- and heat-insulated casing with the

More information

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery PRODUCT DATA COMPACT S BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 375 m 3 /h Comfort heating Comfort cooling Sanitary hot water production COMPACT S Product description

More information

Product Data. Features/Benefits. 36CBAC,AE,AF,AH,AQ,AN, PB,PD,PS Series Active and Passive Chilled Beams. 11 to 190 cfm

Product Data. Features/Benefits. 36CBAC,AE,AF,AH,AQ,AN, PB,PD,PS Series Active and Passive Chilled Beams. 11 to 190 cfm Product Data 36CBAC,AE,AF,AH,AQ,AN, PB,PD,PS Series Active and Passive Chilled Beams 11 to 190 cfm 36CBAC A36-449.eps Chilled beam units offer: An increase in total airflow Sensible cooling and heating

More information

As flexible and logical as you want it. Make the most of your time

As flexible and logical as you want it. Make the most of your time Technical Catalogue for Danfoss Air Ventilation As flexible and logical as you want it. Make the most of your time 3 great reasons to choose Danfoss Air ventilation: Easy installation Comissioning via

More information

RS /E-EV C01 SERIES

RS /E-EV C01 SERIES The well-known RS 300-800/E-EV BLU Burner Series, till now available up to 8 MW, has been upgraded with two new powerful burner models, the RS 1000-1200/E-EV C01 models that extend his max output up to

More information

RoofVent Design Handbook

RoofVent Design Handbook RoofVent Design Handbook Supply and Extract Air Handling Units for Heating and Cooling High Spaces RoofVent RH RC RHC R Content RoofVent RH RC RHC R RoofVent RH Supply and extract air handling unit with

More information

RS /E-EV C01 SERIES

RS /E-EV C01 SERIES The well-known RS 300-800/E-EV Burner Series, till now available up to 8 MW, has been upgraded with two new powerful burner models, the RS 1000-1200/E-EV models that extend his max output up to 12 MW and

More information

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique

More information

KITCHEN EXTRACTORS K Series

KITCHEN EXTRACTORS K Series KITCHEN EXTRACTORS K Series CK-4F CK-5 CK-6F Description Construction The K Series range of centrifugal extractors are specifically designed for the extraction of moist, grease laden air and fumes from

More information

Product Dimensions Page 1 of 7. DA Downdraft Ventilation Hood

Product Dimensions Page 1 of 7. DA Downdraft Ventilation Hood Product Dimensions Page 1 of 7 Location Codes 1 DAG 500 Internal blower The blower box can be mounted in such a way that the vent collar is aligned to the left, the right, downwards or towards the rear,

More information

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS CI/SfB 56.83 X EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS Introduction The Reznor EnviroPak is a new generation of gas fired

More information

Orion-PTV LØV-R with Sirius

Orion-PTV LØV-R with Sirius GB0654 09.17 Orion-PTV LØV-R with Sirius VAV box for supply diffuser Unique damper function Extensive working range Belimo MP-Bus Modbus LONWORKS Belimo KNX TROX Auranor Norge AS PO Box 100 NO-2712 Brandbu

More information

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction Air Comfort Air Treatment Energy Recovery eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction eco PREMIUM - Technical Instruction REDA 2 Contents Description Applications... 3 Quality & environment...

More information

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units. AIR HANDLING UNITS WITH HEAT RECOVERY Series VUT PE EC Series SAS908 control panel SAS908 control panel Ceiling mounted energy saving Air Handling Units (AHU) with the air capacity up to 4000 m 3 /h and

More information

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION Swegon CASA W130 Ventilation unit with counter-flow plate heat exchanger Ventilation unit for residential houses under 250 m². The unit has counter-flow plate heat exchanger. Suitable also for renovation

More information

G Installation Manual (installer & user) QR350MBP Heat Recovery Ventilation Unit

G Installation Manual (installer & user) QR350MBP Heat Recovery Ventilation Unit G Installation Manual (installer & user) QR350MBP Heat Recovery Ventilation Unit Read this manual carefully before using the product and keep it in a safe place for reference as necessary. This product

More information

Lo-Carbon Sentinel Kinetic Horizontal

Lo-Carbon Sentinel Kinetic Horizontal Lo-Carbon Sentinel Kinetic Horizontal MVHR Unit Features & Benefits Manufactured in the UK Building Regulations ADF compliant Recognised in SAP Appendix Q Energy Savings Trust best practice compliant Up

More information

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers elevent ceiling diffusers Technical Selection Swirl, Jet, Louvred and Curved ceiling diffusers Paltech elevent Ceiling Diffusers are protected by: Australian Patent 0179430 + other patents pending Australian

More information

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions) NUAIRE MVHR (including opposite handed versions) ACHIEVES 100% DUTY IN BYPASS MODE and MRXBOXAB- ECO-LP1-OH are specically designed for apartment applications where space is a premium. The new MRXBOX95-LP1

More information

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE FIRE SAFETY AIR TREATMENT FIRE DAMPERS ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE 2 ESAR Smoke control damper Technical catalogue Circular smoke control damper ESAR is specially designed to use in

More information