Código : Motc.PANASC/SANYO-CSB453H8A--6HP-15100fr

Size: px
Start display at page:

Download "Código : Motc.PANASC/SANYO-CSB453H8A--6HP-15100fr"

Transcription

1 Código : Motc.PANASC/SANYO-CSB453H8A--6HP-151fr Section 1. General Specifications Content Unit Specification Compressor Model (Code) C-SB453H8A ( ) Type Application Evap. Temp. Range Compressor Cooling Type Phase Hermetic Scroll Compressor High Back Pressure -15~12 (5~54) Natural Cooling 3 Power Source Voltage Range Rated Voltage Rated Frequency V /44-46 Hz 5/6 V 342~456/396~56 Weight (Including Oil) Refrigerant kg (lb) 39.5(87.1) R22 Oil Type SAY56T or Equivalent Oil Charge ml (fl oz) 17 (57.5) Displacement cm 3 (in 3 ) /rev 1.(6.1) Motor Type Number of Poles 3-PH Induction Motor 2 Electrical Insulation Class E Motor Nominal Revolution Locked Rotor Ampere Winding Resistance [at 25 C (77 F)] min /349 A 66/72 U-V Ω U-W V-W Suction Line (O.D.) mm (in) 22.2 (.875) Connection Tube Discharge Line (O.D.) Compressor Surface Paint mm (in) 12.7 (.5) Black Paint Notes 1 Voltage range is applied at standard rating conditions. 2 Motor specifications in the table are the average values for your reference. 3 ( ): All units with parentheses are reference values. 4 Certifications: CCC certificate No TUV certificate No.Z UL certificate No.SA Expiration of Specification Expiration of this specification shall be effected until issuing a notice with indication of the expiration date from the issued date. In case of improvement or elimination of this specification, it shall be handled by the revision record based on agreement between both sides. 2

2 Section 2. Performance Warranty 2.1 Performance Power Source (3PH) Hz 5 6 V Remark Capacity Input Power Current W 17,7 21,5 ±7% (BTU/hr) 6,392 73,358 reference W 5,43 6,64 ±7% A ±7% Standard Rating Conditions Condensing Temp. Evaporating Temp. Suction Gas Temp. Liquid Temp. Ambient Temp. 54.4(13) 7.2( 45 ) 18.3( 65 ) 46.1(115) 35( 95 ) 2.2 Sound Level Power Source (3PH) Hz 5 V Sound Level db(a) 62Max. 67Max. Notes 1 The operating conditions are the same as MIC location is the distance of 1m (3.28feet) from the compressor. 3 Sound Level is an average sound pressure level in four directions. 2.3 Minimum Starting Voltage Power Source (3PH) Minimum Starting Voltage Conditions Hz 5 V Compressor Temp. Ambient Temp. High Pressure Low Pressure MPa(G)/psig MPa(G)/psig 1~6(5~14) 1~4(5~15) 2(29).5(72) 2.4 Others Content Unit L.P. S. MPa(G)/psig Design Pressure H. P. S. MPa(G)/psig Insulation Resistance MΩ Dielectric Strength V Residual Moisture mg Note: 1. The insulation resistance be measured with a DC5V megohm tester. Specification 1.6(232) 3.(435) 1 (without refrigerant) 24 (1 second) 3 3

3 Section 3. Standard Accessories 3.1 Accessories List Parts Name Qty Parts code Revision No. Note Terminal Box Cover 1 A-11-DSB Installed on Compressor Terminal Box Clip 1 A-21-DSB Installed on Compressor Insulating Grommet 1 A-31-DSB Installed on Compressor Mounting Grommet 4 M-11-DSB Included with Compressor Mounting Sleeve 4 M-21-DSB Included with Compressor Screw Special 1 B-11-DSB Installed on Compressor 3.2 The Drawing for Reference Parts Name Compressor Outline Drawing Mounting Parts Listing Packing Dimensions Nameplate Wiring Diagram Parts Code D-11-DSB M-511-DSB D-21-DSB A-513-DSB E-91-DSB Revision No Inernal Moter Protector (in compressor) Parts Name Specification Trip Temprature 145±5 Inernal Motor Protector Reset Temprature 61±9 Trip Current 57A / 2~1s 4

4 Section 4. Compressor Protection 4.1 Protection Required but not Included with compressor Protection Device Reversal Defensible Relay Crankcase Heater Discharge Thermostat High Pressure Switch Low Pressure Switch Items Features Rated Voltage Rated Power Mounting Position Trip Temperature Reset Temperature Setting Setting Specifications To protect the compressor from reverse rotation AC38V 35 Watts Located within 1mm(4 in )from the compressor shell 13±5 (266 ±1 F) 95±11 (25 ± 2 F) Cut-out seting no higher than 3.Mpa(G) Cut-out seting no lower than.3mpa(g) 4.2 Position of the Protection and Refrigerant Charging FOR LIQUID REFRIGERANT CHARGING CAPILLARY OUTDOOR HEAT EXCHANGER LIQUID LINE SERVICE VALVE INDOOR HEAT EXCHANGER REVERSING VALVET GAS LINE SERVICE VALVE HIGH PRESSURE SWITCH DISCHARGE THERMOSTAT ACCUMULATOR FOR GAS REFRIGERANT CHARGING LOW PRESSURE SWITCH COMPRESSOR CRANKCASE HEATER 5

5 Section 5. Operating Envelope Suction Gas Superheat: 11.1K Refrigerant: R22 7 Transient Operation 6 Condensing Temperature( ) Normal Operation Evaporating Temperature( ) 6

6 Section 6. Application Standard & Limit The following requirements apply to vertical type hermetic scroll compressors: Standard: Applicable to ordinary conditions in Japan JIS B8616 or standards relative to JIS B8616, such as standard rating conditions, maximum operating conditions, low temperature conditions, etc. Limit: Applicable to transitional brief period of time, such as start-up and beginning of defrost mode. No. Item Standard Limit Note 1 Refrigerant R22(Meet the standard of Japan JIS K1517) 2 Evaporating Temp. -15~12 (5~54 F) -25~15 (-13~59 F) Comp. Suction Pressure.2~.62MPa(G)(29~9psig).1~.69MPa(G)(14.5~1psig) 3 Condensing Temp. 3~65 (86~149 F) 1.9~2.6MPa(G)(158~377psig) 68 (155 F) 2.78MPa(G)(43psig) Comp.Design Pressure(High) 3.MPa(G) (435psig) 4 Compression Ratio 5 Winding Temp. 2 ~ (24 F) Max. 125 (257 F) 6 Shell Bottom Temp. 9 (194 F) Max. Evaporating Temp.+12 (21 F) Min. Ambient Temp.+11 (2 F) Min. Operating Not Operating 7 Discharge Gas Temp. 115 (24 F) Max. C-SB:13 ( 266 F) Max. C-SC:135 ( 275 F) Max. Temp. within 1mm(4in) of the discharge fitting. Temp. inside of the well pipe on the top of compressor 8 Suction Gas Temp. Superheat: 5K(1 F)Min. No excessive noise It should meet the requirement of item 5, 6, 7 and 14 within 3cm of the suction fitting. 9 Running Voltage 1 Starting Voltage Within ±1% of the rated voltage Three Phase Models: 85% of the rated voltage min. Single Phase Models: 9% of the rated voltage min. Voltage at compressor terminals. Voltage at compressor terminals. 11 On/Off Cycling On Period: Until the oil level returns to the center of the lower bearing Off Period: Until balance of high and low pressure is obtained For at least 7 minutes - on/3 minutes-off is recommendable. 12 Refrigerant Charge 13 Life Time oil/refrigerant(wt.).35 2, cycle Specific gravity of the Oil: Minimum Oil Level C-SB: Center of the lower bearing C-SB:Bottom of the lower bearing C-SC:No less than 7% of the initial oil charge 15 Abnormal Pressure Rise/Drop System Moisture 16 Level System 17 Uncondensable Gas Level 18 Tilt Pressure Rise: 3.MPa(G) (435psig) Max. Pressure Drop:.3MPa(G) (4.35psig) Min. 2ppm Max. 1 Vol.% Max. Residual Oxygen.1 Vol.% Max. 5 Deg.Max. By high pressure switch By low pressure switch 24 hrs. after vacuuming: 1.1kPa Max. Operation beyond the above limits must be approved by Dalian SANYO Compressor Co., Ltd. (G): Gauge Pressure 7

7 Notes 1 Installation should be completed within 15 minutes after removing the rubber plugs. 2 Do not use the compressor to compress air. 3 Do not energize the compressor under vacuumed conditon. 4 Liquid refrigerant should be charged on liquid line between condenser and receiver. Do not charge the liquid refrigerant on the suction or discharge pipe of the compressor. 5 Do not tilt over the compressor while carrying it. 6 Do not remove the paint. 7 Crankcase heater is required when the oil sump temperature is too low to meet the requirement of item 6 on page7. 8 Voltage fluctuation between compressor terminals, during operation, shall be within 2% of the rated voltage. 9 Do not operate compressor in reverse rotational direction. 1 Suction strainers are recommended for all applications. 8

8 Voltage drop may occur due to the large current draw during compressor starting. We recommend selecting the wire size from the table below. Section 7. Selection of Electrical Wire 6.1 Type of Unit Window & Commercial Type Unit power source 1 outdoor indoor terminal plate 2 compressor Split Type(Separate Type) outdoor power source 1 indoor 2 terminal plate 3 compressor 6.2 Size Table of Electrical Wire Size of electrical wire(mm 2 ) Starting current (A) Remark 1 or Remark 1+2(heat-resistance Temperature: 6 C(14 F) min. ) Remark3(heatresistance Temperature: 12 C(248 F) min.) 5m max. 1m max. 15m max. 2m max. 3m max. 5m max. 1m max. 2max max max max max max max max max max. 12max max max max max max max Caution of Ground The internal motor protector does not protect the compressor against all possible conditions. Please be sure that the system utilizes the ground connection when installed in the field. 9

9 238.2 [9.378] 19.5 [7.55] HOLE 4-φ18 φ.79 No. Part Code Qty Name Compressor 2 A-11-DSB 1 Terminal Box Cover 3 A-21-DSB 1 Terminal Box Clip 4 A-31-DSB 1 Insulating Grommet 5 A-513-DSB 1 Nameplate 6 B-11-DSB 1 Screw Special 12.3 [4.74] [4.889] 19.5 [7.55] 14. [5.513] [5.169] [9.378] DISCHARGE TUBE φ13.1 [φ.516] 77.2 [3.39] [2.923] SUCTION TUBE φ22.3 [φ.878] 68.2 [2.685] U V W [17.785] 259. [1.25] φ176.4 [φ6.952] 31.9 [12.249] 42.8 [16.567] TERMINAL [.985] Part Code D-11-DSB Name Compressor Outline Drawing

10 1 4 [1.575] No. Part QTY Name 1 M-11-DSB 4 Mounting Grommet 2 M-21-DSB 4 Mounting Sleeve 3 B-11-DSB 1 Screw Special WASHER M8 BOLT WASHER SPRING 8 [.315] 3 COMPRESSOR BASE R16 [R.63] 2 [.787] 32 [1.26] [1.811] 37. [1.457] M4[1.575] 1 24 [.945] 19 [.748] 46 [1.811] 2 R3 [R.118] 11 [.433] 1 [.394] 38 [1.496] 46 [1.811] φ8.6 [φ.339] φ1.6 [φ.417] 19 [.748] Part Code M-511-DSB Name Mounting Parts Listing

11 ` 1125 [44.291] [45.197] 116 [45.669] 186 [42.756] [ ] 41 [2.362] 6[2.362] 9[3.543] 6 [2.362] 41 [2.362] 6[2.362] 1-5 [ ] Part Code D-21-DSB Name Packing Dimensions

12 12 13 CODE MODEL C-SB453H8A AC 3PH 5Hz 38,415V AC 3PH 6Hz 44,46V REF. R22 OIL SAY56T DALIAN SANYO COMPRESSOR CO.,LTD. WARNING TERMINAL MUST BE CONNECTED WITH WIRE AS FOLLOWS COMPRESSOR MAY HAVE TROUBLE DUE TO INCORRECT WIRING 注意端子和配线请按照下图标示连接 配线错误可能会导致压缩机故障 3F XXXXXXXXX 8 MFG.DATE XXXX.XX.XX SERIAL NO. XXXXXXX MADE IN CHINA XXXXXX Part Code A-513-DSB Name Nameplate

13 SWITCH V POWER SUPPLY 5Hz 38~415V R S T U INTERNAL PROTECTOR W MAGNETIC SWITCH COMPRESSOR R C 14 POWER SUPPLY 5Hz 22V S T REVERSAL DEFENSIBLE RELAY B A CRANKCASE HEATER Part Code E-91-DSB Name Wiring Diagram

APPROVAL SHEET SPECIFICATIONS OF HERMETIC SCROLL COMPRESSOR C-SBR180H16A

APPROVAL SHEET SPECIFICATIONS OF HERMETIC SCROLL COMPRESSOR C-SBR180H16A No. :WXXS-000-GGSY-12 APPROVAL SHEET SPECIFICATIONS OF HERMETIC SCROLL COMPRESSOR MODEL C-SBR180H16A NO. DATE PAGE REVISION DETAILS SANYO SIGNED CLIENT SIGNED REVISION RECORD USER: MANUFACTURER: DALIAN

More information

Código : Motc.PANASONIC-CSC903H8K-12HP-PARALELO- Section 1. General Specifications

Código : Motc.PANASONIC-CSC903H8K-12HP-PARALELO- Section 1. General Specifications Código : 984031 Motc.PANASONIC-CSC903H8K-12HP-PARALELO- Section 1. General Specifications Section 2. Perform ance W arranty 2.1 Perform ance Standard Rating Conditions 2.2 Sound Level 2.3 Minim um Starting

More information

APPROVAL SHEET S PE CIFICATIONS OF HE R ME TIC S CR OLL COMPR E S S OR CODE MODE L C-S B353H8A

APPROVAL SHEET S PE CIFICATIONS OF HE R ME TIC S CR OLL COMPR E S S OR CODE MODE L C-S B353H8A Dirección: Scalabrini Ortiz 1375, Bs. As. Teléfonos: 4832-6004/6006/5030 E-mail: info@indubel.com.ar No. : J S 02-000-GGS Y-06 APPROVAL SHEET S PE CIFICATIONS OF HE R ME TIC S CR OLL COMPR E S S OR CODE

More information

September 2016 AE Application Guidelines for Copeland CS**KIE Compressors in Ice Machines AE4-1421

September 2016 AE Application Guidelines for Copeland CS**KIE Compressors in Ice Machines AE4-1421 AE4-1421 September 2016 Application Guidelines for Copeland CS**KIE Compressors in Ice Machines TABLE OF CONTENTS Section Page Section Page Safety Safety Instructions... 2 Safety Icon Explanation... 2

More information

Rotary Air-conditioning Compressors Specification

Rotary Air-conditioning Compressors Specification YZG-Q06 Q064Y4/GS Y4/GS-001B Rotary Air-conditioning Compressors Specification YZG-Q064Y4 Compressor Model The Customer Air-conditioner Model QINGAN SIGNATURE CUSTOMER S APPROVAL This document will be

More information

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models)

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models) 4-1280 Application Engineering Bulletin AE-1280R4 Revised April, 1995 APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models) Introduction The Compliant Scroll Compressor has been

More information

1 / 18 AT15C021A MAR SPECIFICATIONS COMPRESSOR (MANAGEMENT MODEL: XI AN DAIKIN QING AN COMPRESSOR CO., LTD.

1 / 18 AT15C021A MAR SPECIFICATIONS COMPRESSOR (MANAGEMENT MODEL: XI AN DAIKIN QING AN COMPRESSOR CO., LTD. 1 / 18 No. MAR.29.2016 SPECIFICATIONS COMPRESSOR MODEL:JT160L-P8Y1@K (MANAGEMENT MODEL: JT160L-P8Y1@K) 2 / 18 1. Range of Application and Assembly 1-1 Applied Range The specifications provided here apply

More information

Danfoss Scroll for Refrigeration MLM / MLZ

Danfoss Scroll for Refrigeration MLM / MLZ s Danfoss Scroll for Refrigeration MLM / MLZ 50-60 Hz - R404A - R507 - R134a - R22 - R407A - R407F http://danfoss.us.com/ Contents Features... 6 Scroll compression principle... 7 The scroll compression

More information

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV Amendment Sheet Code : M5ACV-2005-0002 Date : 08-05-2006 Superceded : M5ACV-2005-0001 Nomenclature Production spec variation Type of ref. connection X : Not applicable Electrical A : 220-240V/1Ph/50Hz

More information

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

POLICY BULLETIN Tecumseh Compressor Company Compressor Group PAGE: 1 of 4 A rotary compressor is a precision piece of equipment, designed and manufactured to very close tolerances. For superior performance and long term reliability the following parameters must

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

COMPRESSOR SPECIFICATIONS

COMPRESSOR SPECIFICATIONS Specifications No. C-0000 15-Apr.-2009 CUSTOMER COMPRESSOR SPECIFICATIONS Compressor type Refrigerant Power source :Scroll Compressor (Involute type) :R404A :1Ph, 220-240V, 50Hz Model Name Nominal Capacity

More information

AE R1 October to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors

AE R1 October to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors October 2017 1.5 to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors Safety Safety Instructions... 2 Safety Icon Explanation... 2 Instructions Pertaining to Risk of Electrical Shock, Fire, or Injury

More information

MAKING MODERN LIVING POSSIBLE. Residential and light commercial scroll compressors Hz R-407C / R-22 / R-410A SELECTION & APPLICATION GUIDELINES

MAKING MODERN LIVING POSSIBLE. Residential and light commercial scroll compressors Hz R-407C / R-22 / R-410A SELECTION & APPLICATION GUIDELINES MAKING MODERN LIVING POSSIBLE Residential and light commercial scroll compressors 50-60 Hz R-407C / R-22 / R-410A SELECTION & APPLICATION GUIDELINES CONTENTS Scroll compression principle... 5 The scroll

More information

AE Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A

AE Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A AE4-1392 July 2014 Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A Section TABLE OF CONTENTS Page Safety Safety Instructions...2 Safety Icon Explanation...2 Instructions

More information

AIR-CONDITIONER SERVICE MANUAL

AIR-CONDITIONER SERVICE MANUAL FILE NO. A90-9608 SERVICE MANUAL AIR-CONDITIONER S SPLIT BUILT-IN DUCT TYPE RAV-362B-PE/ RAV-462B-PE/ SPLIT CEILING TYPE RAV-362C-PE/ RAV-462C-PE/ SPLIT CASSETTE TYPE RAV-362U-PE/ RAV-462U-PE/ PRINTED

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513 TECHNICAL & SERVICE MANUAL SA 123A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-123A 1 851 006 95 Australia SA 123A REFERENCE NO. SM700513 IMPORTANT! Please Read Before

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A TECHNICAL & SERVICE MANUAL SA 183A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. SA-183A 1 851 006 96 Destination Australia SA 183A REFERENCE NO. SM700514 IMPORTANT! Please Read Before

More information

CJ6240CK COMPRESSOR TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD

CJ6240CK COMPRESSOR TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD CJ6240CK COMPRESSOR TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD. 2005.10 INDEX page 1 Compressor Type..2 2 Performance Data.2 3 Running Condition 2 4 Compressor Mechanical Information

More information

NE6210CZ NE6210CZ C O M P R E S S O R TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD

NE6210CZ NE6210CZ C O M P R E S S O R TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD NE6210CZ NE6210CZ C O M P R E S S O R TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD. 2007.3 INDEX page 1 Compressor Type..2 2 Performance Data.2 3 Running Condition 2 4 Compressor

More information

CK C O M P R E S S O R

CK C O M P R E S S O R CJ62 6232 32CK CK C O M P R E S S O R TECHNICAL SPECIFICATION ; HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD. 2011.8 INDEX page 1 Compressor Type..2 2 Performance Data.2 3 Running Condition 2 4 Compressor

More information

HITACHI ROTARY COMPRESSOR MODEL SG153BG3GC I. SPECIFICATION. This specification is applied to SHANGHAI HITACHI rotary compressor. 2.

HITACHI ROTARY COMPRESSOR MODEL SG153BG3GC I. SPECIFICATION. This specification is applied to SHANGHAI HITACHI rotary compressor. 2. HITACHI ROTARY COMPRESSOR MODEL SG153BG3GC I. SPECIFICATION Page 1. 1. SCOPE This specification is applied to SHANGHAI HITACHI rotary compressor. 2. SPECIFICATION OF COMPRESSOR 2.1 Model SG153BG3GC 2.2

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

Danfoss scroll for refrigeration LLZ013 to low temperature

Danfoss scroll for refrigeration LLZ013 to low temperature MAKING MODERN LIVING POSSIBLE Application guidelines Danfoss scroll for refrigeration LLZ013 to 033 - low temperature 50-60 Hz - R404A - R507 http://cc.danfoss.com Contents Features...4 Scroll compression

More information

PUHZ-SHW140YHA PUHZ-SHW230YKA

PUHZ-SHW140YHA PUHZ-SHW230YKA 1 Specifications Model Name PUHZ-SHW1YHA PUHZ-SHWYKA Power supply (phase, cycle, voltage) 3φ, 0V, Hz 3φ, 0V, Hz Max. current A 13.0 6.0 Breaker size A 16 3 Outer casing Galvanized plate Galvanized plate

More information

2 shp 13 lc 1 36 t - 1 a

2 shp 13 lc 1 36 t - 1 a HEAT PUMPs 2SHP3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20645 July 203 Supersedes June 202 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 shp 3 lc 36 t - a Refrigerant Type 2 =

More information

Scroll Compressors for Heat Pump Applications ZH12K4E to ZH11M4E, ZH06KVE to ZH48KVE

Scroll Compressors for Heat Pump Applications ZH12K4E to ZH11M4E, ZH06KVE to ZH48KVE Scroll Compressors for Heat Pump Applications ZH12K4E to ZH11M4E, ZH06KVE to ZH48KVE About this guideline... 1 1 Safety instructions... 1 1.1 Icon explanation... 1 1.2 Safety statements... 1 1.3 General

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338 TECHNICAL & SERVICE MANUAL SA 128S5 FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-128S5-A 1 851 004 09 General (50Hz) & Europe SA 128S5 REFERENCE NO. SM700338 IMPORTANT!

More information

Danfoss scroll compressors In parallel installation SM/SY/SZ

Danfoss scroll compressors In parallel installation SM/SY/SZ Application guidelines Danfoss scroll compressors In parallel installation SM/SY/SZ http://cc.danfoss.com Content Compressor model designation... 4 Nomenclature...4 General overview... 5 Benefits...5

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

A Series Inertia Compressor Applications. Application Bulletin 115

A Series Inertia Compressor Applications. Application Bulletin 115 A Series Inertia Compressor Applications Application Bulletin 115 Application Bulletin Subject: A Series Inertia Compressor Applications Number: 115 Release EN: 006X04 Date: 1/6/92 Revision EN: Z27301

More information

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24 Refrigeration / Air Conditioning Systems Circuit Drawings Nominal Student Hours: Student Resource Package No: NR 24 24 Hours. Delivery: Recognition of Prior Learning: Package Purpose: Suggested Resources:

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

Danfoss scroll compressors SH- In parallel installation

Danfoss scroll compressors SH- In parallel installation MAKING MODERN LIVING POSSIBLE Application guidelines Danfoss scroll compressors SH- In parallel installation 50 Hz - 60 Hz - R410A www.danfoss.com CONTENTS General overview...4 Benefits... 4 Scope...

More information

Danfoss scroll compressors SH - In parallel installation

Danfoss scroll compressors SH - In parallel installation Application guidelines Danfoss scroll compressors SH - In parallel installation 50 Hz - 60 Hz - R410A http://cc.danfoss.com Contents General overview... 5 Benefits... 5 Scope... 5 Design challenge...

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510 TECHNICAL & SERVICE MANUAL SA 93AH FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-93AH 1 851 006 97 Australia SA 93AH REFERENCE NO. SM700510 IMPORTANT! Please Read Before

More information

Technical Manual for LG Compressor

Technical Manual for LG Compressor Technical Manual for LG Compressor Version. 1 LG Electronics Inc. Air Conditioning Compressor Division Contents Ⅰ. Looking into Compressor 1. How the Rotary Works 2. Features of Rotary Compressor Ⅰ -1

More information

Danfoss Inverter scroll compressor, VRJ

Danfoss Inverter scroll compressor, VRJ Application Guidelines Danfoss Inverter scroll compressor, VRJ For Residential Applications - R410A http://danfoss.us.com/ Contents Introduction...6 Scroll compressor components... 6 Compressor size...

More information

Application Guidelines for ZS**KAE Refrigeration Copeland Scroll Compressors HP

Application Guidelines for ZS**KAE Refrigeration Copeland Scroll Compressors HP AE4-1387 R8 April 2015 Application Guidelines for ZS**KAE Refrigeration Copeland Scroll Compressors 1.3-4.5 HP TABLE OF CONTENTS Section Page Section Page Safety Safety Instructions...2 Safety Icon Explanation...2

More information

SUBJECT Model ASH218SV-C8LU SPECIFICATION ASH218SV-C8LU. 1. SCOPE This specification is applied to SHANGHAI HITACHI rotary compressor.

SUBJECT Model ASH218SV-C8LU SPECIFICATION ASH218SV-C8LU. 1. SCOPE This specification is applied to SHANGHAI HITACHI rotary compressor. ASH218SV-C8LU SUBJECT Model ASH218SV-C8LU SPECIFICATION ASH218SV-C8LU PAGE:1/23 1. SCOPE This specification is applied to SHANGHAI HITACHI rotary compressor. 2. SPECIFICATION OF COMPRESSOR 2.1 Model ASH218SV-C8LU

More information

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/ Service Facts Split System Heat Pump 4TWB4024E1000A IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit.

More information

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS Cooling Capacity from 115,000 to 670,000 Btu/hr Btu/hr Smartwise Innovations... Towards Green, Quality & Reliability Solutions SERIES INTRODUCTION

More information

Danfoss scroll compressors SM - SY - SZ

Danfoss scroll compressors SM - SY - SZ MAKING MODERN LIVING POSSIBLE Application guidelines Danfoss scroll compressors SM - SY - SZ R22 - R407C - R137a - R404A - R507A - 50-60 Hz www.danfoss.us.com Content Danfoss scroll compression principle...4

More information

Performer scroll compressors. SM - SY - SZ Hz R22 - R407C - R134a - R404A - R507A. Selection & application guidelines

Performer scroll compressors. SM - SY - SZ Hz R22 - R407C - R134a - R404A - R507A. Selection & application guidelines MAKING MODERN LIVING POSSIBLE Performer scroll compressors SM - SY - SZ - 50-60 Hz R22 - R407C - R134a - R404A - R507A Selection & application guidelines CONTENT PERFORMER SCROLL COMPRESSION PRINCIPLE...5

More information

Application Guidelines for Low Temperature ZF**KAE 1-2.5HP Copeland Scroll Refrigeration Compressors

Application Guidelines for Low Temperature ZF**KAE 1-2.5HP Copeland Scroll Refrigeration Compressors August 2017 Application Guidelines for Low Temperature ZF**KAE 1-2.5HP Copeland Scroll Refrigeration Compressors TABLE OF CONTENTS Safety... 2 Safety Instructions... 2 Safety Icon Explanation... 2 Instructions

More information

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017 Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air

More information

Inverter scroll compressors VZH hybrid manifold

Inverter scroll compressors VZH hybrid manifold Application guidelines Inverter scroll compressors VZH hybrid manifold R410A http://cc.danfoss.com Contents...4 Scope...4 Benefits...4...5 Oil management concept...5 System configuration...5 Dimensions...8

More information

AE R17 November 2016

AE R17 November 2016 AE4-1344 R17 November 2016 Application Guidelines for Copeland RFT, RRT, RST Compressors For Refrigerants R-134A, R-450A,R-513A, R-290, R-404A, R-448A, R-449A and R-507 Section TABLE OF CONTENTS Page Safety

More information

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons) ENGINEERING DATA HEAT PUMP OUTDOOR UNITS HP40 50HZ Capacity 6.2 to 16.3 (21 200 to 55 500 Btuh) Heating Capacity 6.4 to 16.1 (21 800 to 55 500 Btuh) Bulletin No. 490088 October 2004 Supersedes August 1999

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: GRF188R5TAA GRF228R5TAA GRF228R7TAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. GRF188R5TAA 38.7107.083 GRF228R5TAA 38.7107.084 GRF228R7TAA 38.7107.085

More information

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT Service Facts Split System Heat Pump 4A6H5042G1000A CAUTION IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this

More information

Call us today! (800)

Call us today! (800) PA-ACCTR-200 Call us today! (800)341-4297 The 200-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable, efficient and quiet chiller

More information

1. TF Hermetic Reciprocating Compressor

1. TF Hermetic Reciprocating Compressor 1. TF Hermetic Reciprocating Compressor The TF range of refrigeration compressors have cooling capacity from 37 to 1050W and coefficient of performance (COP) from 1.23 to 1.95 W/W. Our products have been

More information

Copeland Scroll. Product Information. Outdoor condensing units for refrigeration applications

Copeland Scroll. Product Information. Outdoor condensing units for refrigeration applications Copeland Scroll Outdoor condensing units for refrigeration applications Product Information Horsepower: 11/2 6 Temperature Applications: Low/Medium/High Refrigerants: R404A Installation Applications: A

More information

Call us today! (800)

Call us today! (800) 500 TON AIR-COOLED CHILLER PA-ACCTR-500 Call us today! (800)341-4297 The 500-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

Mega Top Sandwich Prep Table Manual

Mega Top Sandwich Prep Table Manual Mega Top Sandwich Prep Table Manual Model SUSS-27-12 1. Technical Specifications Amp 115V 3.4A Connection 15 amp plug Name R134a Refrigerant Q'ty (oz) 3.2 Q'ty (gram) 90 HP 1/5 HP Compressor Samsung SD162C-L1U2

More information

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER 2001829 OPERATIONS AND MAINTENANCE MANUAL Prepared by: 860 Douglas Way PO Box 530 Natural Bridge Station, VA 24579 1.0 SCOPE: This Operations and Maintenance

More information

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION AIR CONDITIONERS 2scu3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20644 May 204 Supersedes September 203 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 scu 3 lc 36 t - a Refrigerant

More information

DUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

DUCT type. Большая библиотека технической документации   каталоги, инструкции, сервисные мануалы, схемы. SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit RD-25CA RD-25HA RD-30CA RD-30HA RO-25CA RO-25HA RO-30CA RO-30HA C O N T E N T S SPECIFICATIONS.............................................

More information

Owners Manual Refrigerated Air Dryer MHT SERIES

Owners Manual Refrigerated Air Dryer MHT SERIES Owners Manual Refrigerated Air Dryer MHT SERIES IMPORTANT: READ THIS MANUAL CAREFULLY. IT CONTAINS IN- FORMATION ABOUT SAFETY AND THE SAFETY OF OTHERS. ALSO BECOME FAMILAR WITH THE PROPER INSTALLATION

More information

M P 1 2 F G C O M P R E S S O R TECHNICAL SPECIFICATIO N

M P 1 2 F G C O M P R E S S O R TECHNICAL SPECIFICATIO N M P 1 2 F G C O M P R E S S O R TECHNICAL SPECIFICATIO N (200-220~50Hz & 220-230V~60Hz) REFRITZ LTD 2016.08 1.Compressor Type Compressor model Approximate Power Rated voltage/frequency Refrigerant Application

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

Application Engineering

Application Engineering APPLICATION GUIDELINES FOR ZB*KC/ZB*KCE COPELAND SCROLL REFRIGERATION COMPRESSORS 7 TO 15 HP AE4-1318 R1 June 2008 Introduction The Copeland Scroll ZB*KC/ZB*KCE refrigeration compressor product offering

More information

Danfoss scroll compressors SM SY SZ

Danfoss scroll compressors SM SY SZ Application guidelines Danfoss scroll compressors SM SY SZ R22 - R407C - R134a - R404A - R507A - 50-60 Hz http://cc.danfoss.com Content Compressor model designation... 4 Nomenclature...4 Danfoss scroll

More information

0.4 In the preparation of this standard, assistance has been derived from the following standards:

0.4 In the preparation of this standard, assistance has been derived from the following standards: FOREWORD 0.1 Formal clauses will be added later. 0.2 The committee identified IS 10617(Pt 1), IS 10617(Pt 2) and IS 10617(Pt 3) for the first revision in the light of CFC free/hfc refrigerants and need

More information

General Characteristics SM185S3QC. Dimensions. Terminal box. Electrical Characteristics. Recommended Installation torques

General Characteristics SM185S3QC. Dimensions. Terminal box. Electrical Characteristics. Recommended Installation torques Datasheet, technical data Performer scroll compressor, SM185-3 General Characteristics Model number (on compressor nameplate) Code number for Singlepack* Code number for Industrial pack** Drawing number

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE

More information

Performer Heat Pump scroll compressors 50 Hz - R407C Selection & application guidelines

Performer Heat Pump scroll compressors 50 Hz - R407C Selection & application guidelines MAKING MODERN LIVING POSSIBLE Performer Heat Pump scroll compressors 50 Hz - R407C Selection & application guidelines CONTENTS SCROLL COMPRESSION PRINCIPLE... 3 Scroll compressor components... 3 The

More information

For more Parts Information: https://manitowocfsg.sysonline.com/default.aspx

For more Parts Information: https://manitowocfsg.sysonline.com/default.aspx For more Parts Information: https://manitowocfsg.sysonline.com/default.aspx TABLE OF CONTENTS Manitowoc Foodservice [Updated: Sep. 30, 2013] Manitowoc - Ice & Related Parts Catalog Ice Machine Q Series

More information

Inverter scroll compressors VZH hybrid manifold

Inverter scroll compressors VZH hybrid manifold Application guidelines Inverter scroll compressors VZH hybrid manifold R410A http://cc.danfoss.com Contents...4 Scope...4 Benefits...4...5 Oil management concept...5 System configuration...5 Dimensions...8

More information

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES Service Facts Split System Heat Pump 4A6H5049E1000B IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit.

More information

Concealed Ducted Split Series R-407C MBH

Concealed Ducted Split Series R-407C MBH Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY

More information

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M 2004 Lennox Industries Inc. Dallas, Texas KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04 Supersedes 503,249M Litho U.S.A. COMPRESSOR REPLACEMENT KIT INSTALLATION INSTRUCTIONS FOR COMPRESSOR

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN 4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF FORM NO. 4HP15L-100 (12/2018) COILS Omniguard total corrosion protection technology designed coil Enhanced

More information

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND REFRIGERANT NH4H4 Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS, 208/230

More information

500 EX Fusion Compressor Series

500 EX Fusion Compressor Series 500 EX Fusion Compressor Series R404A M/T R404A L/T Capacity RANGE 13.8kW - 20.4kW 7.7kW -11.2kW Copeland Fusion Semi-Hermetic Horizontal Scroll Compressors For Medium and Low Temperature Applications

More information

MAC-120HE-03 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03

More information

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit RCW-54CB RO-50CA RC-54CA RO-50CA RC-54HA RO-50HA CONTENTS SPECIFICATIONS OUTLINE AND DIMENTIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM

More information

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A Revision B: MUZ-GL09NA- U8 and MUZ-GL09NAH- U8 have been added. Please void OBH733 REVISED EDITION-A. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH733 REVISED EDITION-B Models MUZ-GL09NA

More information

H29A Series Compressor Applications. Application Bulletin 139

H29A Series Compressor Applications. Application Bulletin 139 H29A Series Compressor Applications Application Bulletin 139 Application Bulletin Subject: H29A Series Compressor Applications Number: 139 Release EN: J28319 Date: 4/26/02 Revision EN: Z27301 Date: 10/2/15

More information

Condensing Unit Installation and Operating Instructions

Condensing Unit Installation and Operating Instructions Bulletin WCU_O&I 01 June 2003 Condensing Unit Installation and Operating Instructions WCU Air Cooled Condensing Unit Table of Contents Section 1. Section 2. Section 3. Section 4. Section 5. Section 6.

More information

Owners Manual UA75 TO UA1200 SERIES Refrigerated Air Dryer

Owners Manual UA75 TO UA1200 SERIES Refrigerated Air Dryer 1 Owners Manual UA75 TO UA1200 SERIES Refrigerated Air Dryer DESCRIPTION PAGE INTRODUCTION 2 INSTALLATION 3 INSTALLATION GUIDE 4 DRYER CONTROLS 5 DRYER CONTROLS AND SAFTEY SHUTDOWNS 6 START UP 6 INITIAL

More information

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS SUNLINE 2000ô MODELS: H5CE090, H3CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 9.0-9.5 EER DESCRIPTION These Sunline 2000ô units are completely

More information

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER 2001927 Prepared by: 860 Douglas Way PO Box 530 Natural Bridge Station, VA 24579 1 1.0 SCOPE: This

More information

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2) CS*/CD*/CP* Series Air Cooled Condensing Units Operating and Installation Manual CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2) TABLE OF CONTENTS I. Receipt of Equipment 2 II. Piping...4 III. System

More information

Scotsman Technical Training. CU50 Cube Ice Machine

Scotsman Technical Training. CU50 Cube Ice Machine Scotsman Technical Training CU50 Cube Ice Machine Major Topics Overview Installation Start Up Sequence of Operation Maintenance Diagnostics Service Procedures Models Two Base Models Gravity Drain Pump

More information

Call us today! (800)

Call us today! (800) 150 TON AIR-COOLED CHILLER PA-ACCTR-150 Call us today! (800)341-4297 The 150-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

NM1850 SERVICE PARTS

NM1850 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number in question to be sure that it is applicable to this parts list. NM0 SERVICE PARTS TABLE OF CONTENTS

More information

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH Revision D: Capacity corrections have been corrected [7-1. 2), 3)]. OBH684 REVISED EDITION-C is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH684 REVISED EDITION-D Models MUZ-FH06NA MUZ-FH09NA

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8 Service Facts Split System Cooling 4TTB3048D1000B, 4TTB3060D1000B CAUTION IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain

More information

NM952 SERVICE PARTS TABLE OF CONTENTS. Cabinet Air Cooled Refrigeration Water Cooled Refrigeration Water System Gearmotor...

NM952 SERVICE PARTS TABLE OF CONTENTS. Cabinet Air Cooled Refrigeration Water Cooled Refrigeration Water System Gearmotor... This parts list contains the service parts and wiring diagrams for this model. Check the model number in question to be sure that it is applicable to this parts list. NM9 SERVICE PARTS TABLE OF CONTENTS

More information

DANFOSS OPTYMA PLUS INVERTER UNITS

DANFOSS OPTYMA PLUS INVERTER UNITS Optyma Plus Inverter Condensing Units Danfoss Optyma Plus Inverter Units are designed with the unique benefits of stepless inverter scroll technology resulting in a 20-30% higher energy efficiency in a

More information

Application Guidelines for Glacier K3 Copeland Scroll Refrigeration Compressors

Application Guidelines for Glacier K3 Copeland Scroll Refrigeration Compressors AE4-1296 R3 March 2013 Application Guidelines for Glacier K3 Copeland Scroll Refrigeration Compressors TABLE OF CONTENTS Section Page Section Page Safety Instructions... 2 Safety Icon Explanation... 2

More information

Maneurop reciprocating compressors NTZ

Maneurop reciprocating compressors NTZ Maneurop reciprocating compressors NTZ R404A - R507-60 Hz http://danfoss.us.com/ Content Maneurop reciprocating compressors...5 Features...5 Specifications...6 Technical specifications and nominal ratings...6

More information