SUPPLEMENT PARTS LISTING WIRING DIAGRAMS FOR MT-25,40 & 60EO - KETTLES

Size: px
Start display at page:

Download "SUPPLEMENT PARTS LISTING WIRING DIAGRAMS FOR MT-25,40 & 60EO - KETTLES"

Transcription

1 SUPPLEMENT PARTS LISTING & WIRING DIAGRAMS FOR MT-25,40 & 60EO - KETTLES FORM # S This supplement is based on HEATING ELEMENT CONFIGURATIONS ( see attachments ) titled by styles. Each STYLE is identified with a serial number and corresponding part numbers. In addition, a supporting SPARE PARTS LIST will help identify the most commonly used components for STYLES 2-3-&- 4.A brief description of each style is as follows: STYLE 1: This style is the original version and it is supported by the service & parts manual form # S-2312 rev. 6/85. STYLE 2: This style began with SERIAL NUMBER ( ) and is supported by the spare parts list attached. Uses ( 2 ) screw - in heaters, each rated at 12KW ( SEE ATTACHED WIRING DIAGRAM D ) STYLE 3: This style began with SERIAL NUMBER ( ) and is supported by the attached spare parts lists. Uses a one piece heater design that replaced the heating element configuration outlined in STYLE 2. (SEE ATTACHED WIRING DIAGRAM D ) STYLE 4: This is our current design which began with SERIAL NUMBER ( ) and is supported by the attached spare parts list. Uses ( 2 ) bolt in flanged heaters, each rated at 12KW (SEE ATTACHED WIRING DIAGRAM D ) Revised: 7 / 94

2 Market Forge Ind. HTG. ELE. CONFIGURATIONS FOR MT & -60EO BOILERS STYLE 1 OLDER MODELS COMPONENTS: P/N DESCRIPTION QTY. STATUS HTG.ELE..208V-8KW 3 AVAILABLE HTG.ELE..240V-8KW 3 AVAILABLE HTG. ELE., 480V-8KW 3 AVAILABLE COMPONENTS: P/N DESCRIPTION QTY. STATUS HTG.ELE.,208V-12KW 2 OBS. TO HTG. ELE., 240V- 12KW 2 OBS. TO HTG. ELE., 480V- 12KW 2 OBS. TO PLATE, GASKET 1 AVAILABLE WELDMENT, CVR. PLATE 1 OBS.N.L. A. 35 GARVEY STREET, EVERETT. MA Page 1 MT - - EO:XLS

3 Market Forge Ind. STYLE 3 BEGINING WITH SER # * COMPONENTS: P/N DESCRIPTION QTY. STATUS KTG.ELE., 208V-24KW 1 AVAILABLE HTG.ELE., 240V-24KW 1 AVAILABLE HTG.ELE., 480V-24KW 1 AVAILABLE PLATE, GASKET 1 AVAILABLE STYLE 4 BEG1NING WITH SER # * COMPONENTS: P/N DESCRIPTION QTY. STATUS HTG.ELE., 208V-12KW 2 AVAILABLE HTG. ELE.. 240V - 12KW 2 AVAILABLE HTG. ELE.. 480V- 12KW 2 AVAILABLE GASKET. HTG. ELE. 2 AVAILABLE GASKET, ACCESS CVR. 1 AVAILABLE 6** WASHER, SEALING 12 AVAILABLE 7** HX.HD.1/4-20 X7/8" 12 AVAILABLE 8** LOCKWASHER, 1/4 12 AVAILABLE 9** SIGHT GLASS 1 AVAILABLE 10** REFLECTOR 1 AVAILABLE WELDMENT, CVR. PLATE 1 AVAILABLE * INDICATES THAT THERE MAY BE AN OVERLAP BETWEEN STYLE (3) AND STYLE (4) ** INDICATES COMMON PARTS BETWEEN STYLES & GARVEY STREET. EVERETT. MA Page 2 MT - - EO:XLS

4 MODEL: MT 25, 40 and 60EO BOILERS SPARE PARTS LIST STYLES: 2-3 & 4 PROBE LEVEL CONTROL QTY. PART NUMBER DESCRIPTION LIQUID LEVEL CONTROL BD. (120 volt) LIQUID LEVEL CONTROL BD. ( 240 volt) LIQUID LEVEL PROBE (-water fill) LIQUID LEVEL PROBE (low water level) WATER SUPPLY VALVES SKINNER VALVE ( 120 VOLT ) REMOVABLE STRAINER FOR SKINNER VALVE DRAIN VALVES DRAIN VALVE DRAIN VALVE REPAIR KIT ( new style ) BOILER SHELL SHELL, BOILER FOR STYLE 2 & 3 BOILERS SHELL, BOILER FOR STYLE 4 BOILERS ONLY! ELECTRICAL COMPONENTS TIME DELAY RELAY (120 volt) THERMOSTAT ( drain condensate ) ON - OFF SWITCH S.P.S.T HEAT SWITCH D.P.D.T. ( momentary ) CONTACTOR 40 AMP (120 VOLT COIL ) PILOT LIGHT RELAY SOCKET PRESSURE SWITCHES PRESSURE SWITCH ( high limit) PRESSURE SWITCH ( operating pressure ) MISCELLANEOUS HARDWARE & PLUMBING PRESSURE GAUGE AIR VENT # SAFETY VALVE GASKET. HTG. ELEMENT COVER STYLE 2 & 3 BOILERS GASKET. HTG. ELEMENT COVER STYLE 4 BOILERS ONLY! WATER GAUGE WATER GAUGE GLASS REFLECTC OR DESCALER Page 3 MT40E01.XLS

5 Industries Inc. Employee Owned Company 35 Garvey St.. Everett MA Tel (617) Service Bulletin SB0002 April 24, 1995 TO ALL SERVICE MANAGERS SERVICE BULLETIN NO. SB0002 SUBJECT: MT25,40 & 60EO - KETTLES FORM # S-2312 This bulletin is based on a recent change to the following HEATING ELEMENTS and related wiring NEW LIST PRICE Heating Element Part Number: S Volt Heating Element Part Number: S Volt Heating Element Part Number: S Volt N/A Market Forge has obsoleted Part Number S ( 480 Volt heating element). This application will now be serviced by using Part Number S ( 240 Volt heating element) in its place and wiring the 480 Volts in series across two of the 240 Volt loops ( see attached wiring sketches ). These wiring diagrams will help assist your technician during the install of these new heaters. The Part Number S ( 208 Volt heating element) will remain the same, however, the wiring changes will apply. Please note that the gasket for this heating element is not included with the sale. You will need to order the following Part Number S to support the installation. If you should have any questions concerning this bulletin, please do not hesitate to call either Ms. Lorraine Murphy X179 or myself directly X126. Be sure to make note of the NEW LIST PRICE' Sincerely, Mark Manganiello Sale Administration / Service Manager

6 MT 25, 40 and 60EO WIRING DIAGRAMS FOR STYLE 2 and 3 HEATING ELEMENT REPLACEMENTS WIRING DIAGRAM FOR VOLT 3 PHASE 60 HZ 24 KW. VOLTS AMPS PART NO. ELEMENT Indicates Metal Jumper S S WIRING DIAGRAM FOR 480 VOLT 3 PHASE 60 HZ. 24 KW Indicates Metal Jumper VOLTS AMPS PART NO. ELEMENT S ( 240 VOLT ) NOTE: WHEN USING THIS ELEMENT, SPECIAL CARE MUST BE TAKEN TO REMOVE AND ALIGN THE JUMPERS PROPERLY. Market Forge Industries, Inc. MTEODIA1.XLS

7 Leaders in Foodservice Equipment for over a century. July 5, 1988 TO: ALL PARTS DISTRIBUTORS FROM: DONNA CESINO SUBJECT: NEW HEATING ELEMENTS FOR ULTRA STEAM MODELS: 3005, 3010, 3015 We are discontinuing the following cartridge type heating elements: Part # Description Element, 208 volt. 3 phase Element, 240 volt, 3 phase Element, 208 volt. 1 phase Element, 240 volt, 1 phase The above part numbers will be replaced with a new firebar type heating element. The firebars are very low watt density, resist scale build-up, and are less costly than the original heaters. More good news... one firebar takes the place of (2) 5 KW elements for model 3010 steamer at a good saving for the customer. Firebars also can be connected one or three phase so your stock level is less. Part numbers for Firebar: Part # Description V, 5 KW V, 5 KW V, 10 KW V, 10 KW For easy reference: Model Use Firebar # V 1 or 3 ph

8 Model Use Firebar # V 1 or 3 ph V 1 or 3 ph V 1 or 3 ph V * overall wattage of this model is 1 or 3 ph now reduced from 15 KW to 10 KW V 1 or 3 ph * Overall wattage of this model is now reduced from 15 KW to 10 KW Regards, DC/lh

9 MARKET FORGE COMPANY WIRING DIAGRAM FIREBAR HEATERS ULTRA STEAM MODELS - 5 & 10 KW

Self-Contained Electric Steam Jacketed Kettle

Self-Contained Electric Steam Jacketed Kettle OWNERS MANUAL Self-Contained Electric Steam Jacketed Kettle Model: FT-20CE COVERING: INSTALLATION OPERATION SERVICE & PARTS An Employee Owned Company 35 Garvey Street l Everett l MA l 02149 Tel: (617)

More information

Effective october 14, 2014

Effective october 14, 2014 COS-101 & COS-101S COMBI OVEN STEAMER REPLACEMENT PARTS LIST Effective october 14, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items

More information

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts. CMA Dishmachines 1700 Knott Avenue Garden Grove, CA 981 Toll Free: 1- (800) 8-617 Fax: 1- (71) 89-11 Service Replacement Parts Undercounter High Temperature Dishwasher Model: UC6e M Machine Serial No.

More information

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL EFFECTIVE JULY 31, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution

More information

Effective october 14, 2014

Effective october 14, 2014 COS-20G combi oven-steamer REPLACEMENT PARTS LIST Effective october 14, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified

More information

PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL

PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL EFFECTIVE AUGUST 1, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that

More information

Statement of Responsibilities

Statement of Responsibilities Statement of Responsibilities This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service Representatives who are familiar with both the safety procedures, and

More information

FCT-CE SERIES ELECTRIC TILTING KETTLE W/HAND CRANK PARTS AND SERVICE MANUAL

FCT-CE SERIES ELECTRIC TILTING KETTLE W/HAND CRANK PARTS AND SERVICE MANUAL FCT-CE SERIES ELECTRIC TILTING KETTLE W/HAND CRANK PARTS AND SERVICE MANUAL EFFECTIVE SEPTEMBER 12, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the

More information

Replacement Parts List For Models COS-20G

Replacement Parts List For Models COS-20G Replacement Parts List For Models COS-20G (Ovens with s/n HP & HT) Contents: Page # Electrical Compartment:Contactors,Steam Generator,Thermostats 2-5 Oven Interior: 5 Bottom Section: Gas, Plumbing Components

More information

MP GS/GD 10 GAS. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

MP GS/GD 10 GAS. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800) MP GS/GD 0 GAS Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 36-7745 http://www.garland-group.com FORM # Moisture Plus Gas GS/GD0 (Rev 5) Page 2 FORM # Moisture Plus

More information

ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS

ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS M24E M36E Telephone: (802) 658-6600 Fax: (802)864-0183 www.marketforge.com PN 14-0309 Rev G (11/17) 2017 - Market Forge

More information

Statement of Responsibilities

Statement of Responsibilities Statement of Responsibilities This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service Representatives who are familiar with both the safety procedures, and

More information

Model 10AB/APRB Automatic Dishwasher

Model 10AB/APRB Automatic Dishwasher Model 10AB/APRB Automatic Dishwasher Rinse and Wash Head Assemblies ITEM 1 0126800 End Plug 2 0125000 Rinse Arm Body (only) 3 0126000 Nylatron Washer (2 places) 4 0125500 Hex Nut 5 0126500 Snap Ring 6

More information

Cleveland Range REPAIR MANUAL

Cleveland Range REPAIR MANUAL Cleveland Range REPAIR MANUAL Model No. 6/9CEM18/27/36/48 6/9CGM100/200/250/300 6/9CDM 6/9CSM UNITED STATES 1333 East 179th St. Cleveland, Ohio 44110 Phone: (216) 481-4900 FAX: (216) 481-3782 Cleveland

More information

Replacement Parts List For Models COS-101 COS-101S

Replacement Parts List For Models COS-101 COS-101S Replacement Parts List For Models COS-101 COS-101S (Ovens with s/n HD, HE, HG, HJ) Contents: Page # Front View: Control Panel, Door, Exterior Components 2-4 Oven Interior: 5 Bottom Section: Plumbing Components

More information

RENEWAL PARTS IDENTIFICATION. Type TTUH and TTUH-CO URN Heaters. Dimensions (In.) Extends. Model Volts kw W/In 2 A B C D

RENEWAL PARTS IDENTIFICATION. Type TTUH and TTUH-CO URN Heaters. Dimensions (In.) Extends. Model Volts kw W/In 2 A B C D Chromalox Installation, Operation and RENEWAL PARTS IDENTIFICATION DIVISION DATE SALES REFERENCE (Supersedes PD00-1) OCTOBER, 000 SECTION TTUH PD00-15 161-0815-001 Type TTUH and TTUH-CO URN Heaters TTUH-0A

More information

MODEL CMA-180UC PARTS MANUAL Rev 1.18

MODEL CMA-180UC PARTS MANUAL Rev 1.18 MODEL CMA-180UC PARTS MANUAL Rev 1.18 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS MODEL CMA-180UC 1. PARTS

More information

Statement of Responsibilities This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service Representatives who are familiar with both the safety procedures, and

More information

SCE170 SERVICE PARTS

SCE170 SERVICE PARTS This is the parts list for the SCE170. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The SCE170 has been manufactured in

More information

MODEL CMA-180UC PARTS MANUAL Rev 1.16

MODEL CMA-180UC PARTS MANUAL Rev 1.16 MODEL CMA-180UC PARTS MANUAL Rev 1.16 CMA DISHMACHINES 12700 KNOTT STREET GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS MODEL CMA-180UC 1. PARTS

More information

Statement of Responsibilities

Statement of Responsibilities Statement of Responsibilities This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service Representatives who are familiar with both the safety procedures, and

More information

STEAMPRO. Steam Generator Troubleshooting and Service Guide

STEAMPRO. Steam Generator Troubleshooting and Service Guide STEAMPRO Steam Generator Troubleshooting and Service Guide TABLE OF CONTENTS Page PREFACE... 1 I. STEAMPRO STEAM GENERATOR SYSTEM...2 II. PLUMBING AND ELECTRICAL...3-4 III. SYSTEM OVERVIEW... 5-10 IV.

More information

COS-101 NON SELF FLUSHING COMBI REPLACEMENT PARTS LIST

COS-101 NON SELF FLUSHING COMBI REPLACEMENT PARTS LIST COS-101 NON SELF FLUSHING COMBI REPLACEMENT PARTS LIST EFFECTIVE FEBRUARY 16, 2012 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified

More information

CROWN SERVICE MANUAL ELECTRIC COUNTERTOP STEAMERS MODELS: PX-3 PX-5

CROWN SERVICE MANUAL ELECTRIC COUNTERTOP STEAMERS MODELS: PX-3 PX-5 CROWN SERVICE MANUAL ELECTRIC COUNTERTOP STEAMERS MODELS: PX-3 PX-5 CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, M3N 1V9 TELEPHONE: (416) 746-2358, FAX: (416) 746-8324

More information

Parts Manual. Counter Type Electric Convection Steamer. Series: SteamCraft Models 21CET East 179 th Street Cleveland, Ohio 44110

Parts Manual. Counter Type Electric Convection Steamer. Series: SteamCraft Models 21CET East 179 th Street Cleveland, Ohio 44110 Parts Manual Counter Type Electric Convection Steamer Series: SteamCraft Models 21CET8 1333 East 179 th Street Cleveland, Ohio 44110 Phone: (216) 481-4900 1-800-338-2204 Fax: (216) 481-3782 www.clevelandrange.com

More information

Statement of Responsibilities

Statement of Responsibilities Statement of Responsibilities This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service Representatives who are familiar with both the safety procedures, and

More information

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001 EFFECTIVE: SEPTEMBER 1, 2001 ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 211-0044L-R / 212-0044R-L ADC-44 Conveyor Dishwasher 2

More information

5700 SERIES CONFINED SPACE UNIT HEATER Horizontal or Vertical Mounting

5700 SERIES CONFINED SPACE UNIT HEATER Horizontal or Vertical Mounting 5700 SERIES CONFINED SPACE UNIT EATER orizontal or Vertical Mounting MAINTENANCE MANUAL & INSTALLATION INSTRUCTIONS ATTENTION: Read carefully before attempting to install or operate Unit eater. I NTERTEK

More information

ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL EFFECTIVE MAY, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified are

More information

Electro-HELPS XV ELECTRO-BOILER SPECIFICATIONS. A complete product line to fi t all your application needs. Made in USA

Electro-HELPS XV ELECTRO-BOILER SPECIFICATIONS. A complete product line to fi t all your application needs. Made in USA Electro-HELPS XV Made in USA ELECTRO-BOILER SPECIFICATIONS A complete product line to fi t all your application needs The Electro-Boiler has been heating America s homes and businesses since 980. We take

More information

OWNER S MANUAL MODULAR DIRECT CONNECTED TILTING STEAM JACKETED KETTLE

OWNER S MANUAL MODULAR DIRECT CONNECTED TILTING STEAM JACKETED KETTLE OWNER S MANUAL MODULAR DIRECT CONNECTED TILTING STEAM JACKETED KETTLE MODELS: MT6 MT6T6 MT10 MT10T10 MT10T6 LFT6 LFT10 LFT10T6 LFT10T10 Form Number: S-2306 REV:C 10/12 Printed in U.S.A. 35 Garvey Street

More information

Table of Contents. FETCO, and Driven To Pioneer Innovation are trademarks or trade names of Food Equipment Technologies Company.

Table of Contents. FETCO, and Driven To Pioneer Innovation are trademarks or trade names of Food Equipment Technologies Company. www.fetco.com Hot Water Dispensers User s Guide Maritime Versions Rated IP44 Table of Contents Contact Information... 2 Specifications... 2 Dimensions... 3 Installation... 4 Operating Instructions...6

More information

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL 3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL EFFECTIVE JULY 30, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified

More information

MODELS R & RH 10 THRU 20 RB SERIES ELECTRIC STEAM BOILERS

MODELS R & RH 10 THRU 20 RB SERIES ELECTRIC STEAM BOILERS REIMERS ELECTRA STEAM, INC. 4407 MARTINSBURG PIKE CLEAR BROOK, VA 22624-0037 PHONE:540-662-3811 FAX:540-665-8101 April 01, 2001 MODELS R & RH 10 THRU 20 RB SERIES ELECTRIC STEAM BOILERS INSTALLATION, OPERATING,

More information

GMOS Series OIL-FIRED CAST IRON STEAM BOILER PARTS AND OPTIONAL ACCESSORIES

GMOS Series OIL-FIRED CAST IRON STEAM BOILER PARTS AND OPTIONAL ACCESSORIES MODELS GMOS-3090 GMOS-3090T GMOS-425 GMOS-425T GMOS-585 GMOS-585T GMOS-620 GMOS-620T Ordering Instructions GMOS Series OIL-FIRED CAST IRON STEAM BOILER PARTS AND OPTIONAL ACCESSORIES Order Parts through

More information

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com

More information

Instruction Manual HWR MODEL RESISTO-FLO ELECTRIC BOILER

Instruction Manual HWR MODEL RESISTO-FLO ELECTRIC BOILER Page 1 of 16 Instruction Manual HWR MODEL RESISTO-FLO ELECTRIC BOILER Page 2 of 16 FOREWORD The HWR Resisto-Flo Electric Hot Water Boiler is designed to provide a compact packaged unit requiring a minimum

More information

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION INSTALLATION AND OPERATING INSTRUCTIONS FOR THE HARDY Fuel Oil Furnace Models D-140 & D-350 HARDY MANUFACTURING COMPANY, INC. 12345 ROAD 505 PHILADELPHIA, MS 39350 PHONE: (601) 656-5866 FAX: (601) 656-4559

More information

CME1856W Service Parts

CME1856W Service Parts This parts list contains the part numbers and description of the replacement parts available for this model. To avoid costly and time consuming errors, double check the model and voltage before ordering

More information

Ultra Boiler Series 1 & 2 Jacket Parts

Ultra Boiler Series 1 & 2 Jacket Parts GAS Ultra Boiler Series 1 & 2 Jacket Parts 9 10 8 6 7 1 5 2 3 Fig. Part Description Model Mfr. 1 383-500-135 Jacket Front Door 595-000-000 595-000-001 595-000-002 595-000-003 Panel Door Jacket Plastic

More information

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com

More information

Tubular Industrial Process

Tubular Industrial Process consist of tubular elements welded or brazed into a threaded screw plug which can then be inserted into a threaded opening in a tank wall or through a mating full or half coupling. Standard Screw Plug

More information

Residential Upright Residential Lowboy

Residential Upright Residential Lowboy RESIDENTIAL ELECTRIC REPLACEMENT PARTS LIST Residential Upright Residential Lowboy Includes Hydrojet Total Performance System Effective: April, 2016 ECO 8039 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED

More information

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993 Replacement Parts List No. 055237600 Revision D 08/2017 McQuay Vertical Water Source Heat Pump FCV, FCG, FCW 036, 042 Vintage A Last Manufactured: 1993 To find your Daikin Applied parts distributor, call

More information

OWNER S MANUAL MODELS: ELECTRIC COMPACT CONVECTION OVEN. FORM NO.: S-2374 REV: A 02/07 An Employee Owned Company

OWNER S MANUAL MODELS: ELECTRIC COMPACT CONVECTION OVEN. FORM NO.: S-2374 REV: A 02/07 An Employee Owned Company OWNER S MANUAL ELECTRIC COMPACT CONVECTION OVEN MODELS: 4200 4292 FORM NO.: S-2374 REV: A 02/07 An Employee Owned Company PRINTED IN U. S. A. 35 Garvey Street Everett MA 02149 Tel: (617) 387-47100 Fax:

More information

Model: FT110 Dishwasher

Model: FT110 Dishwasher PARTS MANUAL HOBART FOOD EQUIPMENT CO., LTD Model: FT110 Dishwasher HOBART FOOD EQUIPMENT CO., LTD 2003-07-10 Table of Contents Page Description 2 Panels, Upper chamber and Tank 4 Control Box 6 Control

More information

Quantity X Section Assembly (Intermittent and Continuous Circulation Only)

Quantity X Section Assembly (Intermittent and Continuous Circulation Only) V. Repair Parts Section Assembly and Canopy Group...30 Base Assembly...3 Manifold and Main Burners Inch Main Burners...34 40mm Main Burners...36 Pilot Burner and Gas Valve Continuous Ignition (Standing

More information

MSA-SB-2600 MILITARY SUB-ASSEMBLY HIGH EFFICIENCY ELECTRIC CONVECTION OVEN; OWNER S MANUAL

MSA-SB-2600 MILITARY SUB-ASSEMBLY HIGH EFFICIENCY ELECTRIC CONVECTION OVEN; OWNER S MANUAL S6163-B8-FSE-010 0910-LP-106-4844 TECHNICAL MANUAL MSA-SB-2600 MILITARY SUB-ASSEMBLY HIGH EFFICIENCY ELECTRIC CONVECTION OVEN; OWNER S MANUAL DISTRIBUTION STATEMENT C: DISTRIBUTION AUTHORIZED TO U.S. GOVERNMENT

More information

Assembly Code Identity Data System. Omniclass Number and Title

Assembly Code Identity Data System. Omniclass Number and Title Category Part Type Parameter Name Parameter Group Parameter Type GUID Discipline Type Of Parameter Specialty Equipment Default Elevation Constraints Assembly Code Identity Data Cost Description Keynote

More information

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4) Replacement Parts List No. 700018800 Revision C 08/2012 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design D (4) To find your Daikin Applied parts distributor,

More information

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1) Replacement Parts List No. 110510700 Revision G 02/2015 McQuay Concealed Ceiling Water Source Heat Pump WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1) WCAS, WCDA, WCDL, WCDS, WCMS 030 Design

More information

Indirect Fired Water Heater

Indirect Fired Water Heater Indirect Fired Water Heater 35-119 Gallon Capacities Features Heavy Duty Construction Hydrastone cement lining provides long tank life Copper-silicon tappings cannot rust or corrode High impact composite

More information

CME1856W Service Parts

CME1856W Service Parts This parts list contains the part numbers and description of the replacement parts available for this model. To avoid costly and time consuming errors, double check the model and voltage before ordering

More information

Installation and Maintenance Manual Please retain this manual for future reference.

Installation and Maintenance Manual Please retain this manual for future reference. 342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. Electric Construction Heaters

More information

Cool IR. Model C104 - Cooling System. Instruction Manual

Cool IR. Model C104 - Cooling System. Instruction Manual Cool IR Model C104 - Cooling System Instruction Manual February 26, 2015 Research, Inc. USA Ph: 952.949-9009 Fax: 952.949-9559 tsdsales@researchinc.com www.researchinc.com Table of Contents List of Figures...

More information

HOLDING DRAWERS INTENDED FOR OTHER THAN HOUSEHOLD USE THIS MANUAL FOR FUTURE REFERENCE KEPT CLEAR OF COMBUSTIBLES AT ALL TIMES

HOLDING DRAWERS INTENDED FOR OTHER THAN HOUSEHOLD USE THIS MANUAL FOR FUTURE REFERENCE KEPT CLEAR OF COMBUSTIBLES AT ALL TIMES X*PERT TM SERIESS INSTALLATION AND OPERATING INSTRUCTIONS MODE EL: HDDi/HDDiS/HDXi HOLDING DRAWERS INTENDED FOR OTHER THAN HOUSEHOLD USE RETAIN THIS MANUAL FOR FUTURE REFERENCE UNIT MUST BE KEPT CLEAR

More information

Parts Manual. Gas Floor Type Convection Steamer. Series: SteamCraft Model 24CGA East 179 th Street Cleveland, Ohio 44110

Parts Manual. Gas Floor Type Convection Steamer. Series: SteamCraft Model 24CGA East 179 th Street Cleveland, Ohio 44110 Parts Manual Gas Floor Type Convection Steamer Series: SteamCraft Model 24CGA10 1333 East 179 th Street Cleveland, Ohio 44110 Phone: (216) 481-4900 1-800-338-2204 Fax: (216) 481-3782 www.clevelandrange.com

More information

Barrier Washer. Parts. Refer to Page 3 for Model Numbers. BAR18P_

Barrier Washer. Parts. Refer to Page 3 for Model Numbers.  BAR18P_ Barrier Washer Refer to Page 3 for Model Numbers Parts BAR18P_1300625 www.alliancelaundry.com Part No. 1300625R4 August 2014 Table of Contents Title Page Parts Ordering Information... 2 Serial Plate Location...

More information

MODELS R & RH 24 THRU 120 ELECTRIC STEAM BOILERS

MODELS R & RH 24 THRU 120 ELECTRIC STEAM BOILERS REIMERS ELECTRA STEAM, INC. 4407 MARTINSBURG PIKE CLEAR BROOK, VA 22624-0037 PHONE: 540-662-3811 FAX: 540-665-8101 04/01/04 MODELS R & RH 24 THRU 120 ELECTRIC STEAM BOILERS INSTALLATION, OPERATING, & MAINTENANCE

More information

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993 Replacement s List No. 55209100 Revision E 10/2015 McQuay Console Water Source Heat Pump WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A Last Manufactured: 1993 To find your Daikin Applied parts distributor,

More information

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M 2004 Lennox Industries Inc. Dallas, Texas KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04 Supersedes 503,249M Litho U.S.A. COMPRESSOR REPLACEMENT KIT INSTALLATION INSTRUCTIONS FOR COMPRESSOR

More information

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L EFFECTIVE: MAY, 2014

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L EFFECTIVE: MAY, 2014 EFFECTIVE: MAY, 2014 ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 05/08 The American Dish Service part numbers contained in this

More information

Parts Manual. Floor Type Electric Convection Steamer. Series: Classic Electric Boiler Base Steamer East 179 th Street Cleveland, Ohio 44110

Parts Manual. Floor Type Electric Convection Steamer. Series: Classic Electric Boiler Base Steamer East 179 th Street Cleveland, Ohio 44110 Parts Manual Floor Type Electric Convection Steamer Series: Classic Electric Boiler Base Steamer 1333 East 179 th Street Cleveland, Ohio 44110 Phone: (216) 481-4900 1-800-338-2204 Fax: (216) 481-3782 www.clevelandrange.com

More information

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

Rapide Gas Boilers BRG 80 BRG 120 BRG 200

Rapide Gas Boilers BRG 80 BRG 120 BRG 200 Rapide Gas Boilers BRG 80 BRG 120 BRG 200 Spare Parts 9500-1006 Issue 10 Date Nov 94 Rapide Gas Boilers BRG 200 Spare Parts 9500-1007 Issue 10 Date Nov 94 9500-1101 Key Nº Description Part Nº 10

More information

Installation, Operation, Maintenance and Service Instructions. Fryer Model: 130F

Installation, Operation, Maintenance and Service Instructions. Fryer Model: 130F Installation, Operation, Maintenance and Service Instructions Fryer Model: 130F Star Manufacturing International 10 Sunnen Drive St. Louis, MO.63143-3800 Part Number: 2M-W478 Ph: 314-781-2777 Fax: 314-781-2714

More information

Part No Revised November / Instruction Manual Model #8150 AND #8151

Part No Revised November / Instruction Manual Model #8150 AND #8151 Part No. 88359 Revised November 2003 8150 / 8151 Instruction Manual Model #8150 AND #8151 SAFETY PRECAUTIONS 8150 AND 8151 INSTALLATION FORWARD This manual covers the model # 8150 and 8151 front loading

More information

M50SL / M75SL Parts Manual

M50SL / M75SL Parts Manual M50SL / M75SL Parts Manual American Dryer Corporation 88 Currant Road Fall River, MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 E-mail: techsupport@amdry.com www.amdry.com ADC Part No.

More information

Standard Duct Heaters Open Coil

Standard Duct Heaters Open Coil HUA Slip-In and HUP Flanged Heaters The 80% Rule HEATREX recommends the heater should occupy at least 80% of the actual inside area of the duct, as shown in Figure 45. Only small amounts of air will bypass

More information

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER Compact Design High Recovery Energy Efficient Stainless Alloy Construction Factory Packaged Integral Safety System ASME Constructed & Stamped

More information

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995 Replacement Parts List No. 055236000 Revision B 06/2015 McQuay Ceiling Concealed Horizontal Water Source Heat Pump CCH, CCG, CCW 048, 060 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts

More information

Electric Duct Heaters. IDHB & IDHC Series

Electric Duct Heaters. IDHB & IDHC Series Electric Duct Heaters IDHB & IDHC Series May 2014 1 Duct Heaters Greenheck has a complete line of configurable electric duct heaters that are perfectly suited to your HVAC application. Our CAPS configuration

More information

TSC & TSC-M Proofer/Oven

TSC & TSC-M Proofer/Oven Illustrated Parts List BAKING CENTER BAKING CENTER TSC & TSC-M Proofer/Oven MODELS: TSC-6/8 TSC-6/8M TSC-/9 (Introduced February/009) TSC-/9M (Introduced January/0) This manual is Copyright 07 Duke Manufacturing

More information

B-14G. for series number with jm or j

B-14G. for series number with jm or j B-G boilerless steamer REPLACEMENT PARTS LIST for series number with jm or j Effective june, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that

More information

Cleveland Range Inc. COMBINATION COOK TANK, CHILLER & SOUS VIDE PRODUCTION UNIT. Cleveland General Specifications. Cleveland Standard Features

Cleveland Range Inc. COMBINATION COOK TANK, CHILLER & SOUS VIDE PRODUCTION UNIT. Cleveland General Specifications. Cleveland Standard Features TM MODEL: TJ-100-CC COMBINATION COOK TANK, CHILLER & SOUS VIDE PRODUCTION UNIT Cook/Chill Systems Cleveland General Specifications The capacity of the TurboJet is up to 100 gal. for pumpable (kettle produced)

More information

Barrier Washer. Parts. Refer to Page 3 for Model Numbers. BAR17P_

Barrier Washer. Parts. Refer to Page 3 for Model Numbers.  BAR17P_ Barrier Washer Refer to Page 3 for Model Numbers Parts BAR17P_1300622 www.alliancelaundry.com Part No. 1300622R4 November 2014 Table of Contents Title Page Parts Ordering Information... 2 Serial Plate

More information

Installation Instructions

Installation Instructions Installation Instructions 6 KW and 11.5KW Basic Circulation Water Heater and Pump Application: The Basic Circulation Water Heater has been in use for nearly 50 years, and it is the most prevalent model

More information

Tubular Industrial Process

Tubular Industrial Process Application Tempco Over-the-Side Immersion Heaters are specifically designed for heating fluids in tanks. Depending on the tank shape, size, accessibility and working area inside the tank, choose a round

More information

Flange Heaters - CX. Application. Corrosion. Watt Density. Passivation. Construction. Flange Heaters CX

Flange Heaters - CX. Application. Corrosion. Watt Density. Passivation. Construction. Flange Heaters CX Heaters - CX Heaters CX Application heaters are used to heat liquids or gases in tanks or in-line vessels. Safe and reliable service from the heater requires the correct selection of materials and heating

More information

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com Parts List Modular Crescent Cuber Models KM-901MAJ KM-901MWJ KM-901MRJ/3 hoshizakiamerica.com Number: 71391 Issued: 10-23-2017 Revised: 6-8-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...

More information

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS FOSTORIA INDUSTRIES, INC. A DIVISION OF FES - Series Portable Electric Heaters YES - Series Suspended Electric Heaters (FES-1524-3E shown) IMPORTANT SAFETY INFORMATION INSIDE Serious injury or death possible.

More information

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994 Replacement Parts List No. 05708900 Revision C 06/205 McQuay Incremental Packaged Terminal Air Conditioner MQT 06-4 Vintage B Last Manufactured: 994 To find your Daikin Applied parts distributor, call

More information

MODEL DESCRIPTION PART NO.

MODEL DESCRIPTION PART NO. Electric Parts List Food Warmers NOTE: Always include plate data specifications when ordering replacement parts. MODEL PART Aerohot, Heritage Knob for Infinite Switch 2164 Aerohot, Heritage Infinite Switch,

More information

For more Parts Information:

For more Parts Information: For more Parts Information: https://manitowocfsg.sysonline.com/default.aspx TABLE OF CONTENTS Manitowoc Foodservice [Updated: Sep. 30, 2013] Manitowoc - Ice & Related Parts Catalog Ice Machine Q Series

More information

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2 I&M NUMBER: 316-42-15-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

MXn RACK OVEN SPARES MANUAL MACHINE NO.FG164

MXn RACK OVEN SPARES MANUAL MACHINE NO.FG164 www.monoequip.com MXn RACK OVEN SPARES MANUAL MACHINE NO.FG164 When ordering spares please quote the machine serial number which can be found on the silver information plate of the machine and on the front

More information

MEIKO Undercounter Dish and Glass Washing Machine. Spare Parts List 208V/230V 1/3-PHASE 60 HZ

MEIKO Undercounter Dish and Glass Washing Machine. Spare Parts List 208V/230V 1/3-PHASE 60 HZ MEIKO Undercounter Dish and Glass Washing Machine Spare Parts List FV40.G 08V/0V /-PHASE 60 HZ Rev.. Updated: 0-8-04 CONTENTS. WASH PUMP PAGE. WASH SYSTEM PAGE. BOOSTER PUMP PAGE 7. SOLENOID / FILL VALVE

More information

AG Series Electric Heaters

AG Series Electric Heaters AG Series Electric Heaters Installation, Operation and Maintenance Instructions Internal Auxililary Electric Heat 97B0005N03 Table of Contents Overview 3 Vertical Upflow Installation 4 Horizontal Installation

More information

OPERATING and MAINTENANCE INSTRUCTIONS Taco Bell Hot Cabinet Full Size Model: H137S27D1TB & H137S27D1LTB Half Size Model: H137S273D1TB & H137S273D1LTB

OPERATING and MAINTENANCE INSTRUCTIONS Taco Bell Hot Cabinet Full Size Model: H137S27D1TB & H137S27D1LTB Half Size Model: H137S273D1TB & H137S273D1LTB Rev. 1 (6/15) Page 1 of 5 Taco Bell Full Size Model: & H137S27D1LTB Half Size Model: & H137S273D1LTB H137S27D1LTB H137S273D1LTB Cabinet model number: Cabinet serial number: Authorized Service Agency: Ph:

More information

MODEL CMA-180UC SERVICE & PARTS MANUAL Rev 1.10

MODEL CMA-180UC SERVICE & PARTS MANUAL Rev 1.10 MODEL CMA-180UC SERVICE & PARTS MANUAL Rev 1.10 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 www.cmadishmachines.com 0203 TABLE OF CONTENTS MODEL CMA-180UC

More information

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991 Replacement Parts List No. 055203500 Revision G 05/206 McQuay Climate Control Singer Incremental ES, RS, S 06, 09,, 4 Vintage B Last Manufactured: 99 To find your Daikin Applied parts distributor, call

More information

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models SERVICE MANUAL Troubleshooting Guide and Instructions for Service (To be performed ONLY

More information

961 SERIES CONFINED SPACE UNIT HEATER Horizontal or Vertical Mounting

961 SERIES CONFINED SPACE UNIT HEATER Horizontal or Vertical Mounting 961 SERIES CONFINED SPACE UNIT EATER orizontal or Vertical Mounting ATTENTION: Read carefully before attempting to install or operate Unit eater. FEATURES: Forced air electric unit heater available in:

More information

ARM SERIES Switching Relays With Priority

ARM SERIES Switching Relays With Priority Models ARM-2P ARM-3P ARM-4P ARM-6P AD-1 AD-4 ARM SERIES Switching Relays With Priority INSTALLATION, OPERATION & MAINTENANCE MANUAL ARM-2P ARM-4P AD-1 ARM-3P ARM-6P AD-4 Information and specifications

More information

KARMEL KING Instruction Manual Models: 2620 & 2621 (240 Volt) 2630 & 2631 (208 Volt) Part No Revised: February 2009

KARMEL KING Instruction Manual Models: 2620 & 2621 (240 Volt) 2630 & 2631 (208 Volt) Part No Revised: February 2009 KARMEL KING Instruction Manual Models: 2620 & 2621 (240 Volt) 2630 & 2631 (208 Volt) Part No. 18736 Revised: February 2009 SAFETY PRECAUTIONS Mark 10, Karmel King (20 Gallon), and 2622 Rolling Truck Left

More information

Glass Washer. PERLICK Glass Washer NO ONE WORKS HARDER TO KEEP YOU COOKING. WHALEY FOODSERVICE REPAIRS ITEM PART NO. NO.

Glass Washer. PERLICK Glass Washer NO ONE WORKS HARDER TO KEEP YOU COOKING. WHALEY FOODSERVICE REPAIRS ITEM PART NO. NO. Glass Washer PERLICK Glass Washer 1 50567 Glasswasher Control 2 52536 Spray Arm Drive Motor 3 50445 Wash Pump 4 52528 Pump Motor Capacitor 5 52652-1 Water Inlet Valve 6 52669-1 Band Heater 7 52626A-B Rinse

More information

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model BWXP OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER Electric Heater Company Base Model "BWXP" HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)

More information

Tubular Industrial Process

Tubular Industrial Process Alternate NEMA 1 Housing Type 3N (for no thermostat) for 1", 1-1/4", 2" and 2-1/2" Screw Plug Heaters Screw Plug Immersion Heaters TYPE 4N (for no thermostat) for 1", 1-1/4", 2" and 2-1/2" Screw Plug Heaters

More information

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER Rev. 1 (1/16) Page 1 of 12 INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER REVOLUTION FOODS MODEL CO151027 Rev. 1 (1/16) Page 2 of 12 TABLE OF CONTENTS SUBJECT PAGE INSTALLATION

More information