SECTION ONE - CHEMICAL - TANK VENTING

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "SECTION ONE - CHEMICAL - TANK VENTING"

Transcription

1 GIRARD EQUIPMENT DOT-407 VENT Part Number # GIR-DOT407LT25 The last two digits specify pressure setting. Girard Equipment s DOT-407 vent is a stainless steel, pressure actuated unit that is engineered to limit excessive internal pressure to the tank test pressure. The flow rate of the vent is large enough to provide all the required pressure relief of virtually every DOT-407, DOT-412, MC-307, or MC-312 tank. Equipped with teflon encapsulated o- rings, these vents offer a bubble-tight seal with complete chemical resistance. The entire vent is designed to be easily removed from the tank vehicle for inspection and/or cleaning. The vent is available with different connection options as well as pressure settings. SECTION ONE - CHEMICAL - TANK VENTING 1-1

2 TANK VENTING - CHEMICAL - SECTION ONE GIRARD EQUIPMENT 3 DOT-407 RETROFIT VENT Girard Equipment, Inc. s three inch DOT 407 vents allow you to upgrade virtually any MC307, for MC312 tank trailer to DOT407, or DOT412 venting. All the benefits of the 400 series vents are yours without expensive hot-work. Flow rates are slightly less than standard 4 DOT407 vents, but are more than sufficient for most tank trailers. See table below for specific flow rates. The stainless steel valve seat seals on a Teflon encapsulated silicon O ring. This o ring provides complete chemical resistance and a bubble tight seal to meet the latest DOT requirements. The unit also meet the surge requirements of (b) (3). The three inch vent is designed to be easily removed from the tank for inspection and/or cleaning. PART NUMBER & PERFORMANCE SPECIFICATIONS PART NUMBER MAWP TEST FLOW EXPOSED PRES. (SCFH) SURFACE GIR-DOT3X407T , , GIR-DOT3X407T , GIR-DOT3X407T , ITEM # PART # DESCRIPTION 1 GIR L RAIN COVER 2 GIR L LOW PROFILE UPPER HOUSING, SPECIFY PRESSURE SETTING 3 GIR PRESSURE SPRING 4 GIR L LOW PROFILE POPPET 5 GIR TEF-O-SIL O-RING 6 GIR T MODEL LOWER HOUSING 7 GIR-3TOR SOLID PTFE O-RING 8 GIR F MODEL LOWER HOUSING 9 GSK-RGA301TF 3 TTMA PTFE ENVELOPE FLANGE GASKET 10 GIR AF MODEL LOWER HOUSING 11 GIR TEFLON ENVELOPE ANSI FLANGE GASKET 1-2

3 GIRARD EQUIPMENT DOT 412 VENTS PART NUMBER: GIR-DOT3X407AFTL 3 ANSI FLANGED VENT TEFLON LINED ASK ABOUT RETROFITTING UNLINED VENTS WITH A TEFLON LINER. PART NUMBER: GIR-DOT407LAFTL 4 ANSI FLANGED VENT TEFLON LINED NO NEED FOR RUPTURE DISCS SECTION ONE - CHEMICAL - TANK VENTING 1-3

4 TANK VENTING - CHEMICAL - SECTION ONE 1-4

5 SECTION ONE - CHEMICAL - TANK VENTING 1-5

6 TANK VENTING - CHEMICAL - SECTION ONE FUNCTION The new ultra low-profile Magnetic Vacuum Breaker is a valve design to limit negative pressure (vacuum) in a typical tank trailer. The unit employs the already popular New Generation design, which can be disassembled, cleaned and repaired without the need for special tools. A permanent magnetic force controls the movement of the valve poppet caused by road vibration to open only on demand of 4 Hg or greater. All working parts are kept away from the airflow paths, which promotes easy cleaning and hassle free repairs. This model has a 3 NPS swivel connection and stands less than 4 when installed ona typical tank nozzle making it easy to install under already existing overturn protection. Customers interested in purchasing the older MC307 style 3MVB should consider this new model, which is lower in cost and will provide an increased flow rate over the 3MVB. 1-6

7 SECTION ONE - CHEMICAL - TANK VENTING 1-7

8 TANK VENTING - CHEMICAL - SECTION ONE GIRARD EQUIPMENT DOT-407 VACUUM VENT ASSEMBLY PART NUMBERS PART NUMBER GIR-407MVBTT GIR-407MVBFT GIR-407MVBST GIR-407MVBMT STYLE THREADED, TEF-O-SIL SEAT FLANGED, TEF-O-SIL SEAT STRAIGHT STUB END, TEF-O-SIL SEAT 18 DEGREE STUB END, TEF-O-SIL SEAT Discontinued Parts still available (SUBSTITUTE K FOR T IN PART # FOR KALREZ SEAT) ITEM # PART # DESCRIPTION 1 GIR V/B CAP 2 GIR EP RAIN COVER 3 GIR LOCK RING 4 GIR UPPER BUSHING 5 GIR RETAINING RING 6 GIR S CONICAL SPRING 7 GIR LOWER BUSHING 8 GIR WIPER 9 GIR O POPPET,KALREZ/TEF-O-SIL 10 GIR TS TEF-O-SIL O-RING 11 GIR KO KALREZ O-RING 12 GIR M HOUSING, M-MODEL 13 GIR S HOUSING, S-MODEL 14 GIR B HOUSING, T-MODEL 15 GSK-4TRX SOLID PTFE GASKET 16 GIR F HOUSING, F-MODEL 17 GSK-RGA401TF 4 PTFE ENVELOPE FLANGE GASKET Discontinued. Parts available only. For the latest style, please refer to the New Generation DOT 407 Magnetic Vacuum Breaker vents. 1-8

9 GIRARD EQUIPMENT 3 PRESSURE VENT Vent assembly part numbers: The Girard Equipment MC-307 vent is a stainless steel pressure actuated unit that is engineered to limit excessive internal pressure to 130 percent of tank design. The standard model vent set at 25 PSIG will exhaust 26,700 SCFH at 32.5 PSIG and conforms to the emergency venting requirement code for a spring loaded device that is used of MC-307 transports having a total exposed surface area of 700 square feet. Equipped with Kalrez seals, this vent offers a bubble-tight seal with chemical resistance of teflon. Rating Part Number Style 25,30,35 GIR-MC307BLV## Threaded (Specify Setting) 25,30,35 GIR-MC307FLV## Flanged (Specify Setting) 25,30,35 GIR-MC307MLV## 18 degree (Specify Setting) 25,30,35 GIR-MC307SLV## Str. stub (Specify Setting) Part number identification: Key # Part Number Description 1 GIR Rain Cover Bolt 2 GIR ## Rating Disc (Specify Setting) 3 GIR Rain Cover, low profile 4 GIR Upper Housing, low profile 5 GIR Pressure Spring 6* GIR Wave Ring 7* GIR Upper Spring Retainer 8* GIR Teflon Back-Up Gasket 9* GIR Kalrez Valve Seat 10* GIR Male Spring Retainer 11 GIR ## Lower Housing, Thd Model 11A GIR A-## Lower Housing, Str. Stub Model 11B GIR B-## Lower Housing, 18 Degree Mod. 12 GIR Swivel Nut 13 GSK-3TR 3" PTFE Gasket 14 GIR ## Lower Housing, Flanged Model 15 GSK-RGA301TF 3" TTMA PTFE Env. Gasket * GIR-VSK5 Valve seat kit, Inc. items 6-10 ** GIR-VSK5V Valve seat kit w/vacuum poppet SECTION ONE - CHEMICAL - TANK VENTING 1-9

10 TANK VENTING - CHEMICAL - SECTION ONE 1-10

11 New Design Girard MC307 Pressure Relief Vent Parts Illustration SECTION ONE - CHEMICAL - TANK VENTING 1-11

12 TANK VENTING - CHEMICAL - SECTION ONE GIRARD EQUIPMENT 3 PRESSURE/VACUUM VENT Girard Equipment, Inc. s PV300 Pressure Relief Vent is engineered to limit excessive internal tank pressure to 130 percent of tank design. The standard model vent set at 25 PSIG will exhaust 26,700 SCFH at 32.5 PSIG. A small vacuum section is included, but due to it s limited size, should not be relied upon to provide adequate vacuum protection. Vent assembly part numbers: Rating Part Number Style 25,30,35 GIR-PV300BLV## Threaded (Specify Setting) 25,30,35 GIR-PV300FLV## Flanged (Specify Setting) 25,30,35 GIR-PV300MLV## 18 degree (Specify Setting) 25,30,35 GIR-PV300SLV## Str. stub (Specify Setting) Part number identification: Key # Part Number Description 1 GIR Rain Cover Bolt 2 GIR ## Rating Disc (Specify Setting) 3 GIR Rain Cover 4 GIR Upper Housing 5 GIR Pressure Spring 6* GIR Spring Retainer 7* GIR Teflon Valve Seat w/vacuum 8* GSK Hypalon Gasket 9* GIR Vacuum Ball 10* GIR Vacuum Spring 11 GIR A-## Lower Housing, Str. Stub Model 12 GIR ## Lower Housing,Thd. Model 13 GIR Swivel Nut 14 GSK-3TR 3 PTFE Gasket 15 GIR ## Lower Housing, Flanged Model 16 GSK-RGA301tf 3 TTMA PTFE Env. Gasket * GIR-PVS1 Valve seat kit, Inc. items

13 GIRARD EQUIPMENT 3 VACUUM VENT Key # Part Number Description 1 GIR Rain Cover Bolt 2 GIR Rating Disc 3 GIR Rain Cover 4 GIR Upper Housing 5a GIR Valve Housing, Kalrez 5b GIR T Valve Housing, Tef/Sil 6a GSK PTFE Gasket 6b GIR TS Tef-O-Sil O-ring Gasket 7 GIR Lower Housing, Str.Stub 7a GIR Lower Housing, 18* Stub (Not Shown) 8 GIR Lower Housing, Flanged 8a GSK-RGA301TF 3 TTMA PTFE Env. Gasket 9 GIR Lower Housing, Threaded 9a GIR Swivel Nut 9b GSK-3TR PTFE Gasket SECTION ONE - CHEMICAL - TANK VENTING 1-13

14 TANK VENTING - CHEMICAL - SECTION ONE 1-14

15 GENUINE GIRARD VENT SERVICE KITS GIR-PVS1 VENT SERVICE KIT FOR 3 PRESSURE VACUUM VENT GIR-PVS3 VENT SERVICE KIT FOR 3 PRESSURE VENT GIR-PVS4 VENT SERVICE KIT FOR 3 PRESSURE VENT WITH GIR B REPLACEABLE TEFLON SEAT GIR-VSK5V 3 PRESSURE/VACUUM VENT SEAT, KALREZ GIR-VSK5 3 PRESSURE VENT SEAT, KALREZ GIR T 3 VACUUM BREAKER CAGE ASSEMBLY SECTION ONE - CHEMICAL - TANK VENTING 1-15

16 FUSIBLE CAPS - CHEMICAL - SECTION ONE GIRARD FUSIBLE CAPS Girard Equipment Inc. s fusible caps are tested and marked in accordance with DOT MC306 and MC307 requirements. Fusible metal is placed in an area not in contact with tank lading and sealed by a gasket. Each cap is hydrostatically tested to 75 PSIG on a faced IPT nipple for insurance against leakage in casting or fusible metal. Part Number GIR-3SF GIR-4SF 3 Stainless Steel 4 Stainless Steel GIRARD 3 S/S-POLYMER FUSIBLE CAP Girard Equipment Inc. s new 3 fusible cap is manufactured in accordance with C.F.R for use on MC307 Tank Trailers. A chemically inert thermoplastic polymer is used to join the two-piece cap together. Manufactured from heavy-duty castings, excessive wrenching will neither distort, or damage the fusible material. Part Number GIR-3SPF 1-16

17 GIR-MC307TC 3 PRESSURE VENT TEST CAP GIRARD SOLID CAPS Part Number GIR-3SC GIR-4SC GIR-3AC GIR-4AC 3 Stainless Steel 4 Stainless Steel 3 Aluminum 4 Aluminum GIRARD 3 S/S RING BOSS CAP Part Number GIR-3SC-RB TEST CAPS FOR GIRARD MC 307 STYLE VENTS GIR-3MVBTC 3 VACUUM VENT TEST CAP SECTION ONE - CHEMICAL - PIPE CAPS 1-17

18 VAPOR VENTING - CHEMICAL - SECTION ONE 1-18

19 FORT VALE VAPOR RECOVERY VENT This Fort Vale vapor recovery vent is manufactured in 316 stainless steel with all welds fully homogeneous to ASME design requirements. Standard finish is a high commercial quality electropolish or machine finish. The vent is designed to provide automatic vacuum relief when the discharge valve is opened. The hydraulic activator opens both the Chemical Hydraulic valve and the Vapor Recovery Vent consecutively; with the Recovery Vent opening prior to the Chemical Hydraulic valve. PART NUMBER FOR-57/10030 SECTION ONE - CHEMICAL - VAPOR VENTING 1-19

20 VAPOR VENTING - CHEMICAL - SECTION ONE 1-20

21 SECTION ONE - CHEMICAL - VAPOR VENTING 1-21

22 TANK VENTING - CHEMICAL - SECTION ONE HYDROSEAL SAFETY RELIEF VALVES PART NUMBER PRESSURE & SIZES HYD-1CXV PSI, 1/2 X 3/4 HYD-3CXV PSI, 3/4 X 3/4 HYD-3XCV PSI, 3/4 X 3/4 SARCO STEAM TRAP PART NUMBER STEAM PANEL RELIEF VALVES PART NUMBER PRESSURE & SIZES PVA PSI, 3/4 PVA PSI, 1/2 PVA PSI, 1/2 PVA PSI, 3/4 SIZE SAR /2 SAR /4 SAR BARNES & JONES STEAM TRAP PART NUMBER SIZE BAR-2GW 1/2 BAR-3GW 3/4 1-22

23 BETTS CHEMICAL HYDRAULIC VALVE Betts Industries chemical hydraulic valve is designed for use with a wide variety of chemicals. A replaceable teflon seat and removable disc are provided for ease in repairing should damage occur from dirt or other foreign material. Indicator pins, which move in relation to the piston, show the position of the disc at all times. No shear section provided-for regulated products, protection should be provided by suitable guards as specified in DOT Maximum working pressure is 50 psi. Maximum temperature is 365 degrees F. Part Number Size BET-CH45613SST 4 X 3 BET-CH45586SST 4 X 4 BET-CH45618SST 4 X 3 (Jacketed) SECTION ONE - CHEMICAL - TANK VALVES 1-23

24 TANK VALVES - CHEMICAL - SECTION ONE BETTS CHEMICAL INTERNAL HYDRAULIC VALVE The Betts Chemical Internal Hydraulic Valve is designed to be used for applications where a standard Chemical Hydraulic Valve would prove impractical. Elbow supplied with shear section. Part Number: BET-CH45843SST 1-24

25 BETTS HYDRAULIC VALVE ACCESSORIES BET-CH26165SST 4 X 3 90 DEGREE STANDARD ELBOW BET-CH26166SST 4 X 3 90 DEGREE STEAM JACKETED ELBOW BET-CH17827TF TEFLON REPAIR KIT FOR INTERNAL CHEMICAL HYDRAULIC VALVE BET-CH17828TF TEFLON REPAIR KIT FOR CHEMICAL HYDRAULIC VALVE BET-CH16859SST 4 X 4 90 DEGREE STANDARD ELBOW MOUNTING PAD FOR CHEMICAL HYDRAULIC VALVES BET-MP16914SS (2-7/8 STUD LENGTH) BET-MP16590SS (1-7/16 STUD LENGTH) BET-FP15003BR FUSIBLE PLUG BET-FP15017BR FUSIBLE/FRANGIBLE BREAKAWAY SECTION ONE - CHEMICAL - TANK VALVES 1-25

26 TANK VALVES - CHEMICAL - SECTION ONE BETTS QUICK CLEAN CHEMICAL HYDRAULIC VALVE The Betts Quick Clean Chemical Hydraulic Valves are designed to meet the exacting requirements of todays chemical transport industry. The valve features quick removable spring housing and hydraulic actuator units which provide for easy inspection and maintenance. Encapsulated silicone o-ring seals and the tapered seat provide positive sealing and product retention. An indicator rod shows whether the valve is open. Part Numbers: BET-CH46312SSTS 4 X 3 VALVE, 90 DEGREE ELBOW BET-CH46236SSTS 4 X 4 VALVE, 90 DEGREE ELBOW 1-26

27 BETTS HYDRAULIC PUMP The new Betts Hydraulic Pump has been designed to provide a trouble free, easily maintained pump for use with any Betts hydraulic operated valve. Pump is made of cast iron, has a stainless steel piston, replaceable release valve seat, and an internal pressure relief valve set to bypass at approximately 3000 psi. Part Number: BET-HP19165MS SECTION ONE - CHEMICAL - TANK VALVES 1-27

28 TANK VALVES - CHEMICAL - SECTION ONE BETTS QRB HYDROLET VALVES BET-QR713SST QRB VALVE, 3 90 DEGREE THREADED OUTLET CONSTRUCTED IN T316 STAINLESS. ALSO AVAILABLE IN 4 BET-QR703SST QRB VALVE, 3 90 DEGREE FLANGED OUTLET CONSTRUCTED IN T316 STAINLESS. ALSO AVAILABLE IN 4 BET-JQ713SST QRB VALVE, 3 90 DEGREE THREADED OUTLET, STEAM JACKETED CONSTRUCTED IN T316 STAINLESS. ALSO AVAILABLE IN 4 QRB HYDROLET VALVES AVAILABLE WITH DIFFERENT PIPING CONFIGURATIONS PLEASE CALL FOR PRICING AND AVAILABILITY 1-28

29 BETTS QRB HYDROLET VALVES OS & Y STYLE BET-QY46134SST Designed to mount directly to the Internal Chemical Hydraulic Valve. This valve has a 3 45 degree threaded outlet. BET-QY46136SST Designed to mount directly to the Internal Chemical Hydraulic Valve. This valve has a 3 45 degree threaded outlet, 13.5 long. BET-JY46130SST Designed to mount directly to the Internal Chemical Hydraulic Valve in the rear head of the tank. Flange is offset for least amount of product retention in the tank. SECTION ONE - CHEMICAL - TANK VALVES 1-29

30 TANK VALVES - CHEMICAL - SECTION ONE BETTS QRB HYDROLET VALVES PARTS LIST 1-30

31 BETTS EMERGENCY UNLOADING FIXTURE BET-EM46443SS This fixture is designed to make possible the emergency unloading of an overturned tank through a capped 3 cleanout without spillage of product. After clamping on the unloading fixture as described in the operational instruction sheet, cleanout cap can be removed within the fixture and with proper discharge lines hooked up unload product down to the level of the cleanout. SECTION ONE - CHEMICAL - TANK VALVES 1-31

32 TANK VALVES - CHEMICAL - SECTION ONE Flange by thread models Flange by flange models BETTS GATE VALVES 1-32

33 BETTS HYDRAULIC SLIDING GATE VALVES SECTION ONE - CHEMICAL - TANK VALVES 1-33

34 TANK VALVES - CHEMICAL - SECTION ONE BETTS MECHANICAL EMERGENCY VALVES 1-34

35 BETTS UNIVERSAL MECHANICAL OPERATORS SECTION ONE - CHEMICAL - TANK VALVES 1-35

36 TANK VALVES - CHEMICAL - SECTION ONE BETTS UNIVERSAL MECHANICAL OPERATORS PARTS LIST 1-36

37 CIVACON DRY DISCONNECT COUPLINGS VAPOR RECOVERY ADAPTOR PART NUMBER: CIV-2173AVN DRY DISCONNECT ADAPTOR PART NUMBER SIZE CIV-1673AN CIV-1673AN CIV-1673AN ABOVE PART NUMBERS ARE FOR STAINLESS STEEL ADATORS. ALUMINUM ALSO AVAILABLE. DRY DISCONNECT COUPLER PART NUMBER SIZE CIV-1772D CIV-1772D CIV-1772D ABOVE PART NUMBERS ARE FOR STAINLESS STEEL COU- PLERS WITH VITON SEALS. USE 1775 SERIES FOR CHEMRAZ SEALS. ALUMINUM ALSO AVAILABLE. SECTION ONE - CHEMICAL - TANK FITTINGS 1-37

38 TANK VALVES - CHEMICAL - SECTION ONE SEAL FAST, INC. DRY DISCONNECT COUPLINGS Seal Fast Inc. dry disconnect fittings are interchangeable with Civacon dry disconnect fittings. Part numbers SFI-673A-150 SFI-673A-200 SFI-771D-150 SFI-771D STAINLESS STEEL ADAPTOR, TEFLON SEALS 2 STAINLESS STEEL ADAPTOR, TEFLON SEALS 1.5 STAINLESS STEEL COUPLER, TEFLON SEALS 2 STAINLESS STEEL COUPLER, TEFLON SEALS ALSO AVAILABLE IN ALUMINUM CONSTRUCTION AND A VARIETY OF SEALS. REPAIR KITS ALSO AVAILABLE. 1-38

39 UNIVERSAL AIR COUPLINGS SECTION ONE - CHEMICAL - TANK FITTINGS 1-39

40 TANK FITTINGS - CHEMICAL - SECTION ONE CAM AND GROOVE FITTINGS Available in various sizes and materials such as aluminum, brass, stainless steel, ductile iron, poly-glass and ny-glass 1-40

41 PRESSURE GAUGES & THERMOMETERS PGA-301L-254D LIQUID GAUGE PGA-301D-254D LESS DRY 0-60 ALL STAINLESS FILLED PRESSURE 0-60 ALL STAIN- PRESSURE GUAGE Many other sizes, ranges, and configurations available. Please call for your specific needs. PTH-BT DEGREE THERMOMETER W/5 CAPILLARY TUBE PTH-BT DEGREE THERMOMETER W/5 CAPILLARY TUBE PTH-BT DEGREE THERMOMETER W/5 CAPILLARY TUBE SECTION ONE - CHEMICAL - GAUGES 1-41

42 MANHOLES - CHEMICAL - SECTION ONE BETTS 20 FULL OPENING MANHOLE (NON-ASME) MODEL NUMBER

43 BETTS 20 FULL OPENING MANHOLE (ASME TYPE) MODEL NUMBER 8350 SECTION ONE - CHEMICAL - MANHOLES 1-43

44 MANHOLES - CHEMICAL - SECTION ONE 1-44

45 SECTION ONE - CHEMICAL - MANHOLES 1-45

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT Technical Data SD 4511A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE T14 & T14D TEMPERATURE PILOT PRINTED IN U.S.A. SD 4511A/9811 5 13 /16 D 4 7 /8 1 13 /16 T14 PILOT

More information

SECTION METERS AND GAGES FOR PLUMBING PIPING

SECTION METERS AND GAGES FOR PLUMBING PIPING SECTION 220519 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F

OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F Edition 2013 HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)

More information

Series 1140 and 1141 Temperature Regulators

Series 1140 and 1141 Temperature Regulators Hoffman Specialty Installation & Maintenance Instructions HS-504(E) Series 1140 and 1141 Temperature Regulators! CAUTION FOLLOW ALL INSTALLATION AND OPERATING INSTRUCTIONS. TURN OFF WATER OR STEAM BEFORE

More information

Refrigerant Valves/Accessories

Refrigerant Valves/Accessories Inline Check Valves Compact in-line (non-return) check valves for closure upon pressure reversals. Low Pressure Drop Mounts In Any Position Stainless Steel Disc Safe Working Pressure 400psig Operating

More information

A. This Section includes the following domestic water piping specialties:

A. This Section includes the following domestic water piping specialties: SECTION 221119 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES DIVISION 21 FIRE SUPPRESSION PART 1 GENERAL 1.01 DESCRIPTION A. Provide UL listed, FM approved listed fire protection specialties or accessories as required by either the equipment manufacturer or the

More information

SECTION SECTION DESIGN REQUIREMENTS

SECTION SECTION DESIGN REQUIREMENTS SECTION 26 09 SECTION 23 05 23 DESIGN REQUIREMENTS GENERAL DUTY VALVES GENERAL INFORMATION 1.1 This section applies to valves for hydronic and steam systems. DESIGN REQUIREMENTS 2.1 Design Criteria a.

More information

WAL-RICH CORPORATION SINCE 1950

WAL-RICH CORPORATION SINCE 1950 STEAM SPECIALTIES ANGLE STEAM RADIATOR VALVES 0408102 1/2 1 10 0408104 3/4 1 6 0408002 1" 1 4 0408004 1 1/4" 1 2 0408006 1 1/2 1 2 - Brass - Imported STRAIGHT STEAM RADIATOR GATE VALVES 0409002 1" 1 4

More information

SECTION HEATING BOILER FEEDWATER EQUIPMENT

SECTION HEATING BOILER FEEDWATER EQUIPMENT SECTION 23 53 00 HEATING BOILER FEEDWATER EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes boiler feedwater pumps, de-aerators, accessories, controls and tanks. 1.2 REFERENCES A. ASME (American

More information

Marley Ultra Quiet Fan

Marley Ultra Quiet Fan USER MANUAL Marley Ultra Quiet Fan DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS M2012-1165 ISSUED 8/2012 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. safety and

More information

Division 23 - HVAC Switzerland Beallsville K-12. Section HYDRONIC PIPING SECTION HYDRONIC PIPING PART 1 - GENERAL

Division 23 - HVAC Switzerland Beallsville K-12. Section HYDRONIC PIPING SECTION HYDRONIC PIPING PART 1 - GENERAL Division 23 - HVAC 090070 Switzerland Beallsville K-12 Section 23 21 13 HYDRONIC PIPING SECTION 23 21 13 HYDRONIC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and General Provisions of the

More information

SECTION DOMESTIC WATER PIPING SPECIALTIES

SECTION DOMESTIC WATER PIPING SPECIALTIES SECTION 22 11 19 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

ISO9001:2008 Cert Certified FIRE HYDRANTS. since SFFECO

ISO9001:2008 Cert Certified FIRE HYDRANTS. since SFFECO ISO9001:2008 Cert. 403 Certified FIRE HYDRANTS SFFECO since www.sffeco.com DRY BARREL FIRE HYDRANT Meets all applicable parts of ANSI/AWWA C502 standard UL Listed (EX16453) and FM Approved (FM1510) 250

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS PART 0 A/E INSTRUCTIONS 0.01 Design Requirements A. Pumping system design 1. A primary-secondary pumping system is preferred. Redundant pipes are required for chillers and boilers. 2. Select pumps to operate

More information

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Catalog. Self-operated Regulators Volume 2 Temperature Regulators Catalog Self-operated Regulators Volume 2 Temperature Regulators Self-operated Regulators Temperature Regulators Volume 2 Catalog 2012 Overview Self-operated Temperature Regulators 5 Self-operated Pressure

More information

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description Worldwide Contacts www.tyco-fire.com Model AV--00 Alarm Valve With and Without Model RC- Retard Chamber European Conformity Valve Trim General Description The TYCO Model AV--00 Alarm Valves DN, DN0, DN0,

More information

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL Essex County College - West Essex Campus Addition And Renovations dib # 54292 / 11-14 SECTION 232116 - HYDRONIC PIPING SPECIALTIES PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions

More information

General System Layout Sketch

General System Layout Sketch General System Layout Sketch EZ-37 Solar Panels PV panel Glycol Fill Valve Expansion Tank ` 1 Introduction This document describes how to install a Heliatos GH type solar water heating system. These systems

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

MARK-COSTELLO WASTE STERILIZER SPECIFICATION SHEET

MARK-COSTELLO WASTE STERILIZER SPECIFICATION SHEET MARK-COSTELLO WASTE STERILIZER SPECIFICATION SHEET The Mark-Costello Waste Sterilzer is designed and manufactured in accordance with the following specifications: Vessel shall be built in accordance with

More information

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts. CMA Dishmachines 1700 Knott Avenue Garden Grove, CA 981 Toll Free: 1- (800) 8-617 Fax: 1- (71) 89-11 Service Replacement Parts Undercounter High Temperature Dishwasher Model: UC6e M Machine Serial No.

More information

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job SERIES Commercial, Forced Draft, Hot Water or Steam Boiler Sizes from to,8 MBH output The right fit for any commercial job The Series is built to handle any installation - businesses, institutions, apartments,

More information

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers Bulletin 1200/4 (Revised 5/12) Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers INNOVATORS IN HEAT TRANSFER I. INSTALLATION OF HEAT EXCHANGERS A. HEAT EXCHANGER SETTINGS 1)

More information

REPLACEMENT PARTS MANUAL FOR MODEL: PWS 45-75, AED-2 & APK-4 SERIES

REPLACEMENT PARTS MANUAL FOR MODEL: PWS 45-75, AED-2 & APK-4 SERIES PREC SION Water Systems REPLACEMENT PARTS MANUAL FOR MODEL: PWS 45-75, AED-2 & APK-4 SERIES 0004 0002 0001 PRECISION WATER SYSTEMS WATER DISTILLER MANUFACTURED BY: PRECISION DESIGN & MANUFACTURING INC.

More information

Lasco # Description Picture Lasco # Description Picture

Lasco # Description Picture Lasco # Description Picture TOILET REPAIR 02-1755 2 Pack, White Toilet Seat Hinge 663353 Washer, 02-3133 664625 3-1/16 O.D. x 2-1/8 I.D. x 3/16, Close Coupled Sponge Gasket, Toilet Tank To Bowl Gasket, Sponge Rubber Tank To Bowl

More information

COBRA -300H EXTRACTOR

COBRA -300H EXTRACTOR COBRA -300H EXTRACTOR 120V INFORMATION & OPERATING INSTRUCTIONS DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY 1. Always

More information

Twin-Agent Fire Fighting/Securing Systems Specifications

Twin-Agent Fire Fighting/Securing Systems Specifications Twin-Agent Fire Fighting/Securing Systems Specifications Models 450/50, 450/100, 900/100 & 1350/200 INDEX 1.0 GENERAL 1.1 References 1.2 Submittals 1.3 System Capabilities 1.4 Quality Control 1.5 Warranty,

More information

FLO-RITE-TEMP INSTANTANEOUS WATER HEATER INSTALLATION AND ADJUSTMENT INSTRUCTIONS FOR SINGLE AND DOUBLE WALL UNITS

FLO-RITE-TEMP INSTANTANEOUS WATER HEATER INSTALLATION AND ADJUSTMENT INSTRUCTIONS FOR SINGLE AND DOUBLE WALL UNITS FLO-RITE-TEMP INSTANTANEOUS WATER HEATER INSTALLATION AND ADJUSTMENT INSTRUCTIONS FOR SINGLE AND DOUBLE WALL UNITS Bulletin No. AY-780-L This bulletin should be used by experienced personnel as a guide

More information

SECTION SPRINKLER SYSTEMS

SECTION SPRINKLER SYSTEMS SECTION 15325 SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Wet-pipe sprinkler systems. B. Preaction sprinkler systems. C. System design, installation, and certification. D. Fire department

More information

Spare Parts List (Kits) Model Ref.:- HM35 SERIES A Spare Parts List (Kits) Issue 8 Dated 10-February-2015 Reference Drawing 09-1108-0000 Issue B Dated 07-January 2014 Drawing Ref. Part Number DESCRIPTION

More information

Lubrication Tools and Equipment Portable Oil Drains

Lubrication Tools and Equipment Portable Oil Drains Portable Oil Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s) into a portable

More information

SOLUS-500 EXTRACTOR 120V

SOLUS-500 EXTRACTOR 120V SOLUS-500 EXTRACTOR 120V INFORMATION & OPERATING INSTRUCTIONS DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY 1. Always use

More information

INFINITY FLUIDS CORPORATION

INFINITY FLUIDS CORPORATION INFINITY FLUIDS CORPORATION INFINITY FLUIDS CORPORATION 344 FRANKLIN STREET WORCESTER, MA 01522 888-565-8137 508-347-3674 CRES PRODUCT: WATER/LIQUID HEATER AIR/GAS HEATER INLINE/INSTANTANEOUS STEAM GENERATORS

More information

HHP-300 EXTRACTOR 120V

HHP-300 EXTRACTOR 120V CARPET HHP-300 EXTRACTOR 120V 1 2 CORD 1 3 VAC PUMP UPHOLSTERY MODE INFORMATION & OPERATING INSTRUCTIONS DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTIONS IMPROPER USE OF THE

More information

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance Bulletin 422 Model E Alarm Check Valve Bulletin 422 Instructions for Installation, Operation, Care and Maintenance DN100, DN150, DN200 SIZE Model E with E2 Euro Trim The Reliable Automatic Sprinkler Co.,

More information

Rotary Evaporator Replacement Glassware

Rotary Evaporator Replacement Glassware Rotary Evaporator Replacement Glassware from Glass Glass, founded in 1936, continues our long tradition of manufacturing high quality specialty glassware. We would like to introduce a new, comprehensive

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

MIRAI EXTRACTOR 100V DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

MIRAI EXTRACTOR 100V DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY MIRAI EXTRACTOR 100V LOCATOR 1 2 3 4 MODE VAC 1 VAC 2 PUMP BYPASS INFORMATION & OPERATING INSTRUCTIONS DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE

More information

Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat

Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat Document No. 155-069P25 TH 193-5 Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat 50 60 70 80 TH0356R1 70 60 80 POWERS Description Features The TH 193 HC Hesitation Thermostats are

More information

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS TECHNICAL INSTRUCTIONS Benchmark 3.0LN 24-Month Maintenance Kit# 58015-04 This kit applies to units with an Ignitor and a separate gas injector. For units with an Ignitor-Injector (P/N 58023), see Kit

More information

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW MODEL V Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW Features Industrial Grade Construction Stainless steel pressure vessel provides maximum service

More information

Worldwide Contacts. Technical Data

Worldwide Contacts.  Technical Data Worldwide Contacts www.tyco-fire.com Model BFV- Butterfly Valve Wafer Style General Description The TYCO Model BFV- Wafer Style Butterfly Valves are indicating type valves designed for use in fire protection

More information

Rotary Evaporator Replacement Glassware

Rotary Evaporator Replacement Glassware Rotary Evaporator Replacement Glassware from Ace Glass Ace Glass, founded in 1936, continues our long tradition of manufacturing high quality specialty glassware. We would like to introduce a new, comprehensive

More information

Technical Data. Sizes 2 12 Inch (DN50 DN300)

Technical Data. Sizes 2 12 Inch (DN50 DN300) Worldwide Contacts www.tyco-fire.com Model BFV- Butterfly Valve Wafer Style General Description The TYCO Model BFV- Wafer Style Butterfly Valves are indicating type valves designed for use in fire protection

More information

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage Model: 1090 1 Safety instructions Float-Controlled Condensate Trap, PN 16 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination

More information

ALARM VALVE MODEL: SDH-AVA TECHNICAL DATA : OPERATION DESCRIPTION. Flange X Groove Groove X Groove Bar (250 PSI)* WORKING PRESSURE

ALARM VALVE MODEL: SDH-AVA TECHNICAL DATA : OPERATION DESCRIPTION. Flange X Groove Groove X Groove Bar (250 PSI)* WORKING PRESSURE ALARM VALVE MODEL: SDH-AVA TECHNICAL DA : MINAL SIZE END CONNECTION 200, 50, 00, & 80 Flange X Flange Flange X roove roove X roove MAXIMUM WORKIN PRESSURE THREADED OPENIN MOUNTIN DESCRIPTION 7.5 Bar (250

More information

KINNEY OIL MIST ELIMINATORS

KINNEY OIL MIST ELIMINATORS KINNEY OIL MIST ELIMINATORS Models: A B, B1 & B2 C1 D & D1 Instruction Manual 1855-1 Revision 12/01 TABLE OF CONTENTS DESCRIPTION... 1 OPERATION... 1 ELEMENTS... 2 OIL RETURN METHODS... 3 DIRECT DRAIN

More information

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM SECTION 21 10 00 PART 1 - GENERAL 1.1 CODES A. Work shall conform to NFPA 13 Sprinkler Systems, 2002 Edition and NFPA 24 Outside Protection, 2002 Edition. NFPA 14 Standpipe Systems, 2000 Edition and International

More information

THERMOSTATIC STEAM TRAPS

THERMOSTATIC STEAM TRAPS THERMOSTATIC STEAM TRAPS Nicholson is the originator of the bellows actuated Thermostatic Steam. Nicholson s thermostatic product range spans applications from critical tracing to high capacity process.

More information

CombiBloc Close-coupled centrifugal pumps

CombiBloc Close-coupled centrifugal pumps CombiBloc Close-coupled centrifugal pumps CombiBloc CombiBloc is the premier solution for pumping clean thin liquids in a very cost-effective way. The pump is part of Johnson Pump s Combi-system, a modular

More information

INSTRUCTION AND REPAIR MANUAL

INSTRUCTION AND REPAIR MANUAL SECTION 6 ITEM 390 DATED JANUARY 2003 SUPERSEDES SECTION 6 ITEM 390 DATED OCTOBER 2000 INSTRUCTION AND REPAIR MANUAL SERIES 390 6 The 390 Series is a superior commercial Multi-Stage Vertical In-Line Centrifugal

More information

SECTION HYDRONIC PIPING

SECTION HYDRONIC PIPING SECTION 23 21 13 HYDRONIC PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes pipe and fitting materials, joining methods, special-duty valves, and specialties for the following: 1. Hot-water

More information

Flow Control for Fire Protection

Flow Control for Fire Protection Flow Control for Fire Protection Valve Solutions From An Industry Leader AmesFireWater.com Count on the Fire Protection Leader for Reliable Flow Control Solutions Ames provides a range of high-quality

More information

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements. FIRE PROTECTION GENERAL INFORMATION 1.1 Refer to Section 230000 for General Mechanical Requirements. 1.2 Refer to Section 230529 for Hangers and Supports. 1.3 Refer to Section 230553 for Pipe and Equipment

More information

Series SR Compact Centrifugal Mag-Drive Pumps. WARRENDER, LTD. Process & OEM Pumps From Stock or Built-to-Spec

Series SR Compact Centrifugal Mag-Drive Pumps. WARRENDER, LTD. Process & OEM Pumps From Stock or Built-to-Spec WARRENDER, LTD. Process & OEM Pumps From Stock or Built-to-Spec Series SR Compact Centrifugal Mag-Drive Pumps Providing environmentally safe sealless, magnetic pumps of the highest quality for over 30

More information

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE:

More information

Noiseless Heater Vacuum Relief Valve

Noiseless Heater Vacuum Relief Valve Noiseless Heater Vacuum Relief Valve -1 Step Type/Structure/Features Please refer to this for structure and feature of Noiseless Heater and Vacuum Relief valve. Step 1 Selection Please look at the ID chart

More information

Protected with TechCoat finish. For Ceramic Tile Showers Cast iron Threaded for test nipple Extra heavy (.050) strainer DRAIN CONNECTION

Protected with TechCoat finish. For Ceramic Tile Showers Cast iron Threaded for test nipple Extra heavy (.050) strainer DRAIN CONNECTION QUICK CONNECT SHOWER DRAIN Protected with TechCoat finish Quick Clamping Gasket And Collar For Ceramic Tile Showers Cast Iron Clamping collar securely attaches drain to drain line Speeds installation Extra

More information

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Italy - DE112/0404 Oil burners fuel unit with solenoid valve Type VM The DELTA

More information

DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE

DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE SAWAFUJI ELECTRIC CO., LTD. GENERAL: This appliance is designed to convert

More information

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV) SUBCOURSE EDITION EN5113 5 US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV) US ARMY PLUMBER MOS 51K SKILL LEVELS 1 AND 2 COURSE PLUMBING FIXTURES (PLUMBING IV) SUBCOURSE NO. EN5113 US Army Engineer

More information

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No. SECTION 22 63 13 GAS PIPING FOR LABORATORY AND HEALTHCARE FACILITIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

B. Shop Drawings: Detail fabrication of pipe anchors, hangers, special pipe support assemblies, alignment guides, expansion joints and loops,

B. Shop Drawings: Detail fabrication of pipe anchors, hangers, special pipe support assemblies, alignment guides, expansion joints and loops, SECTION 23 21 13 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

1.1 This section applies to air handling units for HVAC Systems.

1.1 This section applies to air handling units for HVAC Systems. AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling

More information

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS 2016, 2024, and 8111

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS 2016, 2024, and 8111 OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS 2016, 2024, and 8111 Contents: Safety Information Installation Operation Maintenance Trouble-Shooting Guide Specifications Warranty Parts List and Exploded View

More information

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to HOW TO ORDER page. PT5 Thermodynamic Steam Traps MATERIAL : No. PART MATERIAL QTY. (Nos.). BODY ASTM A743 Gr. CA 40 0 (Seat Hardened) (Cast Equiv. AISI 420) 2. DISC CAP ASTM A743 Gr. CA 40 0 (Cast Equiv. AISI 420) 3. DISC

More information

SOLUS-310R EXTRACTOR

SOLUS-310R EXTRACTOR SOLUS-310R EXTRACTOR 120V INFORMATION & OPERATING INSTRUCTIONS DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY 1. Always

More information

DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY KING COBRA 500 120V INFORMATION & OPERATING INSTRUCTIONS DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY 1. Always use

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2008 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR COILS 505,264M (65484504) 05/08 Supersedes 10/07 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE

More information

Air Vents AV-392. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps.

Air Vents AV-392. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps. Leak-tight Positive closing, free-floating stainless steel lever ensures leak-tight closing under all conditions.

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR POINT OF USE STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL PS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR POINT OF USE STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL PS INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR POINT OF USE STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL PS Edition 2011 HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615

More information

Page 1 of 18. Part# /5/2013

Page 1 of 18. Part# /5/2013 Part# 1002655-06 8/5/2013 This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly and keep for future reference INSTRUCTIONS

More information

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime. Armstrong Mini Pump Bulletin AFH-223 The Armstrong mini pump trap is the smallest non-electric solution that can move condensate or other liuids from lower to higher points and from lower to higher pressures.

More information

D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS

D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS GENERAL: This document provides performance requirements and guideline information for Heat Exchanger equipment for Colorado College only, and is not

More information

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity 100 PPD (2 kg/h) Chlorine or Sulfur Dioxide 250 & 500 PPD (5 & 10 kg/h) Chlorine or Sulfur Dioxide Anti-Siphon Ejector

More information

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need. A wide range of process thermostatic steam traps is available to match almost any application need. FEATURES Simple construction Easy to maintain as installed Excellent air handling capability Pressure

More information

Installation, Operation & Maintenance Instructions

Installation, Operation & Maintenance Instructions Installation, Operation & Maintenance Instructions 313 OVERFLOW TRAP TALE OF CONTENTS Overview... Cover General Information... Cover Installation... 4 Operation... 4 Maintenance... 4 Float all Level Test

More information

WET/DRY VACUUM Models PF51, PF53, PF55, PF57

WET/DRY VACUUM Models PF51, PF53, PF55, PF57 WET/DRY VACUUM Models PF51, PF53, PF55, PF57 OPERATING INSTRUCTIONS COMMERCIAL WET/DRY VACUUM Equipment must be operated, serviced and maintained in accordance with the manufacturer s instructions. Save

More information

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS SECTION 15501 WET AUTOMATIC FIRE SPRINKLER SYSTEMS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Wet automatic fire sprinkler systems including fire pump, fire pump controller, alarms, safety devices,

More information

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps... PUMPS FOR INDUSTRY CONTENTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Series 600 Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Series

More information

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS TID-0004_0A TECHNICAL INSTRUCTIONS Hardware Procedure: Coil and Riser Replacement Procedures for All Styles of A, B, C, and D Indirect-Fired Water Heaters Applies to: Indirect-Fire Water Heaters. Description

More information

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function HERZ-3000 Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function Standard Sheet for 3791 3792 Edition 1000 (0999) Dimensions in mm 1 3001 01 Cone sleeve 1 3002 01 Connection

More information

WHEELED STORED PRESSURE

WHEELED STORED PRESSURE OWNERS SERVICE MANUAL NO. 19795 INSTALLATION, OPERATING & SERVICING INSTRUCTIONS All fire extinguishers should be installed, inspected and maintained in accordance with the National Fire Protection Association

More information

Boiler Manual. Water & steam boilers Series 2 for use with Gas, Light Oil, & Gas/Light Oil Fired Burners. Maintenance Parts. Installation Startup

Boiler Manual. Water & steam boilers Series 2 for use with Gas, Light Oil, & Gas/Light Oil Fired Burners. Maintenance Parts. Installation Startup 88 Water & steam boilers Series 2 for use with Gas, Light Oil, & Gas/Light Oil Fired Burners Boiler Manual Installation Startup Maintenance Parts For additional information, refer to.. Burner specification

More information

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260 SERIES 40/40D AND C250/260 Designed for a variety of high pressure and high capacity applications found in utility, industrial and marine service FEATURES Designed to fail open. Designed for superheat

More information

24 VAC SYSTEM CONTROL KIT

24 VAC SYSTEM CONTROL KIT 24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas draft induced appliances with a 24 VAC Gas Valve and a 30-millivolt

More information

Full-line Product Overview

Full-line Product Overview Full-line Product Overview End Suction Centrifugal Pumps This general purpose pump can be configured in frame-mounted and close-coupled, semi-open and enclosed impeller configurations. They are available

More information

NewlyDesignedfor MaximumPerformance

NewlyDesignedfor MaximumPerformance Standard Drawer Magnets NEO FF Series NewlyDesignedfor MaximumPerformance Bunting NEO FF Series Drawer Magnets are outfitted with super-strong neodymium Rare Earth magnets that capture and hold ferrous

More information

COBRA -H EXTRACTOR 120V

COBRA -H EXTRACTOR 120V COBRA -H EXTRACTOR 120V INFORMATION & OPERATING INSTRUCTIONS CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

More information

Yarway Narvik Steam Desuperheater Series 4300 TempLow

Yarway Narvik Steam Desuperheater Series 4300 TempLow For precise and economical control of steam temperature Features and benefits Easy installation Installation in straight, vertical or horizontal pipe. Minimal headroom is required for mounting Only standard

More information

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12 Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12 GENERAL The Powerex oil-less tank mounted system is designed to provide clean, dry air for industrial applications where the

More information

Boiler Manual. Water & steam boilers Series 2 for use with Gas, Light Oil, & Gas/Light Oil Fired Burners. Burner specification and data sheets

Boiler Manual. Water & steam boilers Series 2 for use with Gas, Light Oil, & Gas/Light Oil Fired Burners. Burner specification and data sheets 88 Water & steam boilers Series 2 for use with Gas, Light Oil, & Gas/Light Oil Fired Burners Boiler Manual For additional information, refer to.. Burner specification and data sheets for burners pre-tested

More information

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps... PUMPS FOR INDUSTRY CONTENTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Series 600 Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Series

More information

TEMPERATURE CONTROLLERS

TEMPERATURE CONTROLLERS Instruction Manual: H1 T-12 Thermostat PILOT GUARD INTRODUCTION: SCOPE: This instruction manual includes installation, operation, and parts information for the Kimray Thermostat and Pilot Guard. Refer

More information

Packaged Steam Fired Water Heater

Packaged Steam Fired Water Heater MODEL ST Packaged Steam Fired Water Heater Utilizes Steam To Heat Domestic Water, Semi-Instantaneous or Storage Type Heaters Features Reliable Packaged System Only high grade materials used in construction

More information

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description Worldwide Contacts www.tyco-fire.com Model ESFR-17 16.8 K-factor Dry Type Pendent s Early Suppression, Fast Response General Description TYCO Model ESFR-17 Dry Type Pendent s are Early Suppression, Fast

More information

UL/FM Fire Protection Products Setting the Standard

UL/FM Fire Protection Products Setting the Standard UL/FM Fire Protection Products Setting the Standard Markets Power Institutional Company Overview Mueller Co. is a leader in high-quality commercial and institutional fire protection products, offering

More information

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions 0772150/4 IM-P077-02 ST Issue 4 S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Commissioning

More information

HARMSCO INSTALLATION AND OPERATION MANUAL UPFLOW SWIMMING POOL CARTRIDGE FILTER CARTRIDGE CLEANING INSTRUCTIONS HARMSCO CARTRIDGES

HARMSCO INSTALLATION AND OPERATION MANUAL UPFLOW SWIMMING POOL CARTRIDGE FILTER CARTRIDGE CLEANING INSTRUCTIONS HARMSCO CARTRIDGES HARMSCO INSTALLATION AND OPERATION MANUAL UPFLOW SWIMMING POOL CARTRIDGE FILTER CARTRIDGE CLEANING INSTRUCTIONS HARMSCO CARTRIDGES May be cleaned and reused before replacement is necessary. Cartridge cleaning

More information