Heat Link. Canada. Plumbing, Heating, & Panels Product Catalog / Price List. Effective July 1, 2014

Size: px
Start display at page:

Download "Heat Link. Canada. Plumbing, Heating, & Panels Product Catalog / Price List. Effective July 1, 2014"

Transcription

1 Heat Link Plumbing, Heating, & Panels Product Catalog / Price List Effective July, Canada

2

3 Heat Link About Us HeatLink is a multi-system supplier of potable water and radiant hydronic heating/cooling and snow melt systems. For over 20 years we have created comfortable and efficient heating, cooling and plumbing systems for residential and commercial construction. HeatLink s radiant heating systems create a comfortable and energy efficient environment for living. Our snow melt systems create safer public and private spaces that reduce liability for property owners, reduce maintenance, and ensure accessibility. Our well engineered plumbing systems provide peace of mind for property owners through extensive warranty protection, and enable quick and efficient installations for builders and contractors. History HeatLink began as a family owned business developed to service a number of industries including HVAC. The company grew to meet the needs of builders, contractors, and architects and began designing and installing radiant heating systems in 985. Since 985 HeatLink has grown into an industry leading designer and manufacturer of radiant heating, cooling, and potable water systems. HeatLink has developed and manufactured a long list of industry firsts such as the TwistSeal tool-less manifold in 996. The company began manufacturing PEX-a tubing in 998 and now supplies the highest quality PEX-a systems to customers throughout North America and parts of Europe and Asia. HeatLink works with a network of experienced and successful partner agencies to meet the design, system installation and training needs of the construction industry, designers, and architects. Solutions HeatLink in an industry leader in providing a broad range of potable water and radiant heating/cooling and snow melt systems for customers throughout the world. Our focus from our inception remains on creating well engineered and energy efficient solutions that are easy to install and last a lifetime. Company Description Our innovative plumbing and heating systems help provide a comfortable and worry free environment for people in residential and commercial work and living spaces. We continue to design quiet and energy efficient heating and potable water systems that are easy to install and last a lifetime. HeatLink was built on a strong family work ethic and a value system that remain the foundation for our continuing growth and industry leadership role.

4 Heat Link Table of Contents Discounts Structure & Shipping Allowances... Terms and Conditions of Sale, Delivery and Payment... 4 Heating PEX Heating Tubing with O 2 Barrier... 5 PEX Heating Tubing Non Barrier... 7 TwistSeal (55 mm) Manifold Assembly Kits... 9 TwistSeal (55 mm) Manifold Modules...0 TwistSeal Mini (40 mm) Manifold Assembly Kit...2 TwistSeal Mini (40 mm) Manifold Modules... TwistSeal Manifold Accessories Stainless Steel Manifolds Stainless Steel Manifold Accessories Stainless Steel Manifolds Stainless Steel Manifold Accessories...20 Manifold Housings...22 PEX Compression Adapters way Injection Mixing way Compact Mixing System way Mixing System way Mixing System...28 Mixing Valves...29 Valves...2 Mixing Valve Motors...5 Thermostatic Heads...6 Actuators...7 Thermostats V AC Relay...42 StatLink Modules...4 Controls...44 Sensors...45 Wet System...48 DryAbove System...5 DryBelow System...52 Floor Heating Accessories...5 Chemicals...56 Water Testing...57 Sidestream Filter...58 Plumbing PureLink Potable Water PEX-a Tubing... 7 PureLink Pipe-in-Pipe... 2 EasyFit Manifold HPP Multiport Tees SS Press Sleeves PEX Insert Couplings PEX Insert Elbows PEX Insert Threaded Elbows... 0 PEX Insert FNPT Adapters... PEX Insert Fixture Adapters... 2 PEX Insert MNPT Adapters... PEX Insert Sweat Adapters... 4 PEX Insert Tees... 4 PEX Insert Plugs... 7 Ball Valves... 8 Stubout Elbows Accessories, Tools, and Parts Accessories... 4 Tools Parts Listing by Stk# Listing by Stk# Mechanical Room in a Box (Panels) Introduction...60 System Panel Selection...6 ECO - ECO Boiler Panels...62 V00 - V00 Boiler Panels...64 CAD - CAD Boiler Panels...66 ELBP - Electric Boiler Panels...68 TMP -Way Mixing Panels...72 TWH Tankless Water Heater Panels...80 HEP Isolation Heat Exchanger Panels...86 WHP - Water Heater Panels...90 CDP 2-Temperature Combi DHW Panels...92 SOL - Solar Heat Exchanger Panel...98 SSM - Stainless Steel Manifold Panels SSP - Stainless Steel Manifold Pump Panels SSTS - Stainless Steel Manifold Small Mixing Panels SSTL - Stainless Steel Manifold Large Mixing Panels SMP Snow Melt Panels Snow Melt Panel Options & Accessories

5 Heat Link Discounts Structure & Shipping Allowances Please note: this price list supersedes all previous price lists. For your discount please contact your local sales representative. Shipping Allowances Prices and specifications are subject to change without notice. Products shipped in multiples of quantity listed only. Standard shipping times: D/C pickups: Minimum order value: Rush orders: Backorders: Prepaid freight: Fuel surcharge: days from confirmed order (or less). days from confirmed order (or less), scheduled with local HeatLink shipping department. $00.00 net Same day shipment if order confirmed by AM. Next day if order confirmed after AM. Next day freight charges applicable. Rush charges may apply. Shipped with subsequent order to stocking distributor (if no subsequent order is in place, product will be shipped freight prepaid ground n/c). $ 5,000 net minimum order. Subject to change without notice. May apply on prepaid orders. Rates are subject to change without notice.

6 Heat Link Terms and Conditions of Sale, Delivery and Payment General Provisions. (a) This agreement, performances of contract and quotations are made exclusively upon the terms and conditions set out below. Alterations or deviations from the provisions herein contained shall not be binding upon HeatLink Group Inc. unless confirmed in writing. (b) The Purchaser hereby accepts the terms and conditions herein contained in their entirety. Stipulations of terms and conditions contrary to the provision hereof according to the Purchaser s business or purchasing practices, invoicing, manner of payment or custom of the trade are hereby specifi cally agreed to be inapplicable to this agreement. (c) In the event that any one or more of the provisions herein contained shall become or be deemed to be invalid, illegal or unenforceable by operation of law, the validity, legality and enforceability of the remaining provisions or any part thereof shall not in any manner be affected or impaired thereby. In place and stead of any such invalid, illegal or unenforceable provisions of any part thereof, the parties hereto shall be deemed to have agreed upon terms and conditions, which, as far as permitted by law, express the intent and purpose of the within terms and conditions. Plans and Specifications 2. Drawings, specifications and technical data appended to or forming part of the agreement shall at all times remain the property of HeatLink Group Inc., with all rights reserved and shall not be provided, submitted or disclosed to third parties without the express written consent of HeatLink Group Inc. Changes, alterations, deletions or additions thereto shall not be binding upon HeatLink Group Inc. unless confirmed in writing. Prices and Quotations. (a) HeatLink Group Inc. hereby specifi cally reserves the right to change, alter, amend or revoke quotations but the same shall become binding and irrevocable only upon written acceptance by both HeatLink Group Inc. and the Purchaser or upon delivery to and acceptance of goods by the Purchaser. (b) Prices are, save and except as otherwise agreed upon, as at HeatLink Group Inc. s location in Calgary, Alberta, Canada, exclusive of cost of packaging, crating, freight or shipping, federal, provincial or local rates, tariffs and taxes in effect on date of delivery. (c) All contract prices are guaranteed for thirty (0) days from date of contract. Cost increases 0 days after contract date, including but not limited to cost increases of materials, wages, fuel, transportation or energy charges and increases in applicable federal, provincial and local rates, tariffs or taxes shall be added to the contract price and form part thereof as if originally agreed upon. (d) Contracts for delivery of goods or performance of services without specifi c agreement as to price shall be subject to the price or prices in effect on the date of delivery of goods. Terms of Payment 4. (a) Save and except as otherwise specifically agreed upon in writing, all invoices or accounts, as the case may be, shall become due and payable in full without deduction whatsoever thirty (0) days after invoice or account date. (b) Holdbacks or deductions of any kind whatsoever without prior written authorization from HeatLink Group Inc. are expressly prohibited. (c) Discounts, if any, shall be calculated on the cost of goods as per invoice, exclusive of cost of packaging, crating, freight or shipping, federal, provincial or local rates, tariffs or taxes, where applicable, or other costs or surcharges beyond control of HeatLink Group Inc. (d) Payment will be in a form agreed to and acceptable by HeatLink Group Inc. All costs for dishonour, presentment for payment or collection shall be at the expense of the Purchaser and Payor. All payments by cheque, whether certified or uncertifi ed, shall be deemed as having been received on the date of acceptance for payment of the said cheque or cheques by the Purchaser s or Payor s bank, trust company or fi nancial institution upon whose account the cheque has been issued. (e) Payments received shall be applied fi rstly to designated accounts, dishonour or collection; secondly, to outstanding interest charges on the oldest accounts; and, thirdly, the balance, if any, of any payment shall be applied to the most recent accounts, outstanding balance or balances. If an account is past due at the time of payment, then application of received funds will be in the order best interest to HeatLink Group Inc. (f) In the event the Purchaser defaults in payment or causes a cheque, bank draft or money order to be dishonoured or stops payment thereon, or HeatLink Group Inc. shall deem the Purchaser insecure, all accounts shall forthwith become due and payable notwithstanding any agreement as to credit or periodic payment. (g) Overdue accounts shall bear interest at the rate stated on the face of the invoice or (if no rate is displayed on the invoice), 2% calculated and compounded monthly. Reservation of Title and Property 5. (a) It is hereby expressly agreed that all goods shall remain the exclusive property of HeatLink Group Inc. and title shall not pass until payment in full of all invoices or accounts rendered, including cost of goods, packaging, carting, shipping or freight charges, federal, provincial or local taxes, rates and tariffs, insurance, extras to contract, interest charges, exchange or collection expenses and other sums or charges applicable has been received pursuant to the terms and conditions herein contained. (b) Goods delivered shall not, in any event, become part of real estate and the Purchaser shall at all times take or initiate all steps necessary to preserve HeatLink Group Inc. s right, title and property to such goods. (c) The Purchaser shall not permit any goods sold or delivered by HeatLink Group Inc. to be pledged or encumbered without express written consent from HeatLink Group Inc. In the event of seizure by third parties, the Purchaser shall forthwith disclose HeatLink Group Inc. s reservation of title, right and property to such goods and shall forthwith notify HeatLink Group Inc. of such seizure and shall assist HeatLink Group Inc. at the Purchaser s cost in the preservation and enforcement of HeatLink Group Inc. s right, title and property to the said goods. (d) In the event of breach of contract by the Purchaser of the terms or conditions herein contained and, in particular, default of payment of invoices as hereinbefore provided, HeatLink Group Inc. shall be entitled, without prior notice, to demand delivery up of goods sold and delivered and to seize the same wherever the same may be located at any time of day or night or to cause its agents, workmen or bailiffs to seize the same, wherever the same may be located at any time of day or night notwithstanding the goods may be in possession of a subsequent purchaser or user. (e) Seizure of goods by HeatLink Group Inc. shall not be deemed to constitute termination of contract or contractual rights and obligations as between HeatLink Group Inc. and the Purchaser. Delivery of Goods 6. (a) HeatLink Group Inc. shall at all times use its best efforts to maintain the delivery dates agreed upon. The delivery date or period shall be deemed to have been maintained or complied with in all events, cases or situations where the goods to be delivered leave HeatLink Group Inc. s premises on or before such date, before the expiry of such period or the Purchaser is notified before the applicable date that the goods are ready for shipment. (b) Delivery dates or periods shall be extended by reason of delays causes by labour shortages, strikes or lockouts or other circumstances beyond the reasonable control of HeatLink Group Inc. Any delay or postponement of delivery to HeatLink Group Inc. of goods and supplies by its suppliers, subcontractors or co-contractors caused by strike, lockout, labour shortage or unrest or other causes beyond the reasonable control of HeatLink Group Inc., its suppliers, subcontractors or co-contractors shall in like manner extend delivery dates and periods as if the same applied to HeatLink Group Inc. (c) In the event of delay in delivery of goods caused by the Purchaser for any reason whatsoever, HeatLink Group Inc. shall be entitled to charge the cost of storage calculated at the rate of one half (/2%) percent per month upon the cost of goods, such calculation commencing one month after delivery of Notice of Readiness for shipment and continuing for each and every month or part thereof thereafter until the goods can be delivered to the Purchaser. Risk of Property 7. (a) Commencing on the date of delivery of goods for shipment or transport to the Purchaser, the said goods or any part thereof shall be at the risk of the Purchaser. (b) Any goods or part thereof delivered for shipment or transport to the Purchaser from the factory Calgary, Alberta, or elsewhere, including goods with unessential or minor defects, shall be deemed to have been accepted by the Purchaser without recourse. (c) Defi ciencies or defects in goods or part thereof shipped or the shipment of the wrong goods, or part or part thereof, shall be endorsed upon the bill of lading and shall be communicated to HeatLink Group Inc. in writing within three () business days of arrival at destination. Failing such notifi cation, the Purchaser shall be deemed to have accepted the goods without recourse. Return of Goods 8. (a) All or any goods returned without prior authorization by HeatLink Group Inc. shall not be accepted. (b) If returns are authorized by HeatLink Group Inc., goods will be accepted as follows: (i) New and unused goods upon authorization by HeatLink Group Inc., with freight to be prepaid plus 25% restocking charge. (ii) Outdated goods, with freight prepaid plus 25% restocking charge plus refurbishing costs. (c) In all cases, unless express written authorization is given, goods must be returned in condition for immediate resale. If goods and packaging are not in condition for immediate resale, HeatLink Group Inc. reserves the right to refuse to accept the returned goods, charge additionally for refurbishing goods or packaging, or any other agreed to return remedy negotiated with the customer. In all cases, HeatLink Group Inc. will have the fi nal approval as to whether returned goods are accepted or unaccepted under any of the above remedies. Insurance 9. During the period commencing with the delivery of goods for shipment or transport to the Purchaser and ending upon receipt of payment in full for the said goods pursuant to the terms and conditions hereof, the Purchaser shall insure the said goods in the joint names of HeatLink Group Inc. and the Purchaser against all risk of loss or damage howsoever caused. Applicable Law 0. All disputes, claims or demands arising from or relating to warranties, guarantees, representations authorized and published by HeatLink Group Inc., and from the terms and conditions herein contained and all claims, demands, rights or liabilities arising from such warranties, guarantees, representations or terms and conditions shall be determined in accordance with the laws of the Province of Alberta, Canada. 4

7 Heat Link PEX Heating Tubing with O 2 Barrier Special Order* PEX Tubing Coils with O 2 Barrier Series High molecular cross-linked poly eth yl ene (PEX) with minimum bend ing radii of 6 the diameter at 68 F (20 C). Maximum op er at ing tem per a ture: PSI ( kpa). Covered by a twen ty-five year manufacturer s limited warranty. Comes with oxygen diffu sion barrier which pre vents ox y gen from entering the heat ing system through the tubing wall. Stk# Description Pkg Qty Carton Skid Qty Unit List Price / Unit 942 8" 00ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing 40 coil " 250ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing 40 coil " 00ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing 40 coil " 500ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing 20 coil " 000ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing 6 coil " 00ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing 20 coil " 500ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing 6 coil " 000ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing 2 coil " 00ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing 48 coil " 00ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing 6 coil " 500ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing 2 coil " 000ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing 5 coil 9428 " 00ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing 9 coil " 500ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing 5 coil " 00ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing - 4" 00ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing - 2" 00ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing - 2" 00ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing 4 coil 5 coil 5 coil 5 coil Radiant Heating & Cooling * Check with your local representative for availability. 5

8 Heat Link PEX Heating Tubing with O 2 Barrier Radiant Heating & Cooling PEX Tubing Straight Lengths with O 2 Barrier Series High molecular cross-linked poly eth yl ene (PEX) with minimum bend ing radii of 6 the diameter at 68 F (20 C). Maximum op er at ing tem per a ture: PSI ( kpa). Covered by a twen ty-five year manufacturer s limited warranty. Comes with oxygen diffu sion barrier which pre vents ox y gen from entering the heat ing system through the tubing wall. Stk# Description Pkg Qty Master Carton Bag Qty Unit List Price / Unit " 0 20ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing " 5 20ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing - 4" 5 20ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing - 2" 5 20ft O 2 Barrier HeatLink UV Stabilized PEX-a Tubing 20 bundle 20 bundle 20 bundle 20 bundle HeatLink O 2 Barrier Pipe-in-Pipe Sheathed Series PEX-a carrier tubing specified on previous pages. The flexible, impact resistant red PE sheath designed as a raceway for electrical installations provides mechanical and UV protection to the PEX-a carrier tubing. The sheath allows for easy replacement of the PEX-a carrier tubing if needed. Minimum bending 68 F (20 C) for: 2" = " (77 mm) PE sheath is rated to UL94HB Tests for Flammability of Plastic Materials. Corrugated sheath outside diameter for: 2" = 5 6" (2 mm) Stk# Description Pkg Qty Carton Skid Qty Unit List Price / Unit New! 9405rs 2" 00' O 2 Barrier HeatLink Pipe-in-Pipe Red Sheath 4 coil Special Order* 9422rs 4" 00' O 2 Barrier HeatLink Pipe-in-Pipe Red Sheath 9 coil 6 * Lead time may vary. Call to confirm time line.

9 Heat Link PEX Heating Tubing Non Barrier Non Barrier PEX Tubing Coils & Series High molecular cross-linked poly eth yl ene (PEX) with minimum bend ing radii of 6 the diameter at 68 F (20 C). Maximum operating tem per a ture: PSI ( kpa). Covered by a twen ty-five year manufacturer s limited warranty. Stk# Description Pkg Qty Carton Skid Qty Unit List Price / Unit WSL " 200ft Non-Barrier HeatLink UV Stabilized PEX-a Tubing coil " 00ft Blue PureLink Plus UV Stabilized PEX-a Tubing 2 coil " 500ft Blue PureLink Plus UV Stabilized PEX-a Tubing 20 coil " 000ft Blue PureLink Plus UV Stabilized PEX-a Tubing 4 coil " 00ft Blue PureLink Plus UV Stabilized PEX-a Tubing 4 coil " 500ft Blue PureLink Plus UV Stabilized PEX-a Tubing 9 coil " 000ft Blue PureLink Plus UV Stabilized PEX-a Tubing 5 coil 2028 " 00ft Blue PureLink Plus UV Stabilized PEX-a Tubing 9 coil 2028 " 00ft Blue PureLink Plus UV Stabilized PEX-a Tubing 9 coil Radiant Heating & Cooling 7

10 Heat Link TwistSeal (55 mm) Manifolds Features & Benefits : Modular tool-less assembly. Multiple configurations from basic to deluxe (all interchangeable; can be reconfigured on-site). Unlike a fixed loop manifold, loops can be added or removed as required. Stock is flexible, as there is no need to stock fixed-length manifolds. Minimal SKUs on the shelf. Balancing return. Zone valve supply with manual shut-off; accepts optional actuators. Max. trunk flow rate: kit - 8 US gpm (4. m /h) kit - 22 US gpm (5 m /h) Max. circuit flow rate: 2.5 US gpm (0.57 m /h) 8", 2", 5 8", and 4" tubing to manifold connecters available. Test rated to over F water temperature. 5 year limited warranty. L to R 2" & 4" PEX insert tubing to manifold connecters (79400 assembly kit shown with module pairs and 2 actuators) Typical Applications: Commercial. Snow melting. L to R 8", 2", 5 8", & 4" tubing to manifold connecters (79402 assembly kit shown with module pairs and 2 actuators) Assembly Kit or 7940 or # of Loops Choose Recommended Housing* Module Type Additional Brackets Balancing Recessed** Surface Mount n/a n/a n/a n/a Actuator Selection Actuator with LED Actuator with End Switch Tubing Size Tubing to Manifold Connecters / Loop Conduit Elbows / Loop for Wet Installation Compression PEX Insert 8" 7702 n/a " " 7709 n/a " * Recommended housing based on kit and 90 mains piping. ** Thermometers must be removed.

11 Heat Link TwistSeal (55 mm) Manifold Assembly Kits TwistSeal (55 mm) Deluxe Manifold Assembly Kit Stk# This package contains the items need ed to assemble a Deluxe TwistSeal Manifold. Contents include: 2 mounting brackets 2 - " FNPT supply end connections 2 closed end caps lube bottle 2 cross tees c/w - 2" cross tee plugs thermometer pair c/w wells manual air vent with key au to mat ic air vent hose bib wrench for plastic nut Radiant Heating & Cooling " TwistSeal (55mm) Deluxe Manifold Assembly Kit 20 ea. TwistSeal (55 mm) Basic Manifold Assembly Kit Stk# 7940 This package contains the items need ed to assemble a TwistSeal Man i fold. Contents include: 2 mounting brackets 2 - " FNPT supply end connections 2 closed end caps lube bottle Wrench (#79922) sold separately " TwistSeal (55mm) Basic Manifold Assembly Kit 20 ea. TwistSeal (55 mm) Commercial Manifold Assembly Kit Stk# This package contains the items need ed to assemble a Com mer cial TwistSeal Manifold. Contents include: 2 mounting brackets " MNPT supply end connections 2 closed end caps lube bottle 2 cross tees c/w - 2" cross tee plugs thermometer pair c/w wells manual air vent with key au to mat ic air vent hose bib wrench for plastic nut " TwistSeal (55mm) Commercial Manifold Assembly Kit 20 ea. 9

12 Heat Link TwistSeal (55 mm) Manifold Modules Radiant Heating & Cooling Mounting Bracket (55 mm) Stk# 7999 Plastic mounting bracket which al lows easy snap-on mount ing of manifolds TwistSeal (55mm) Mounting Bracket TwistSeal Deluxe (55 mm) Supply / Return Modules c/w Heavy Duty Zone Valve Supply & Balancing Return Stk# The supply module provides on/off manual control to allow iso la tion of individual loops, and may be fitted for electric actuator and ther mo stat op er a tion. The return mod ule permits the bal anc ing of the flow rate. Comes with o-rings. Modules can be locked in place with a couple of turns. No threaded rod, solder, or tools required. Just twist and seal TwistSeal Deluxe (55mm) Z.V. Supply & Balancing Return Module Pair 0 pair 0

13 Heat Link TwistSeal Mini (40mm) Manifolds Features & Benefits : Modular tool-less assembly. Multiple configurations from basic to deluxe (all interchangeable; can be reconfigured on-site). Unlike a fixed loop manifold, loops can be added or removed as required. Stock is flexible, as there is no need to stock fixed-length manifolds. Minimal SKUs on the shelf. Maximum trunk flow rate: US gpm (2.5 m /h) Maximum circuit flow rate: 7800 and 7820 series - US gpm (0.2 m /h) US gpm (0.28 m /h) 8", 2", 5 8", and 4" tubing to manifold connecters available. Test rated to over F water temperature. 5 year limited warranty. Typical Applications: Residential. Small commercial. L to R 2" & 4" PEX insert tubing to manifold connecters (79200 assembly kit shown with 7822 and 782 module pairs and 2 actuators) 782x Module Specific Features: Lockable balancing return. Zone valve supply with manual shut-off; accepts optional actuators. L to R 8", 2", 5 8", & 4" tubing to manifold connecters (79200 assembly kit shown with 7802 and 780 module pairs and 2 actuators) 780x Module Specific Features: Lockable balancing return with US gpm ( L/min) flow meter. Zone valve supply with manual shut-off; accepts optional actuators. Assembly Kit # of Loops Balancing Choose Module Type Multiport Balancing Multiport Flow Meter Additional Brackets Recommended Housing* Recessed Surface Mount n/a Actuator Selection Actuator with LED Actuator with End Switch Tubing Size Tubing to Manifold Connecters / Loop Compression PEX Insert Conduit Elbows / Loop for Wet Installation 8" 7702 n/a " " 7709 n/a *recommended housing based on kit and 90 mains piping 4"

14 Heat Link TwistSeal Mini (40 mm) Manifold Assembly Kits Radiant Heating & Cooling TwistSeal Mini (40 mm) Deluxe Manifold Assembly Kit Stk# This package contains the items needed to assemble a mini deluxe heating manifold. Contents include: 2 mounting brackets 2 - " union cross tee end connection c/w green fibre gasket 2 - " MBSP " FNPT adapter 2 red rubber gaskets for air testing 2 closed end caps - 2" cross tee plug thermometer pair 2 automatic air vents hose bib lubricant package " TwistSeal Mini (40mm) Deluxe Manifold Assembly Kit 20 ea. Mini Mounting Bracket (40 mm) Stk# Plastic mounting bracket which allow easy snap-on mounting of manifolds. Offset provides tubing passage behind 2 nd manifold TwistSeal Multiport (40mm) Double Mounting Bracket 2

15 Heat Link TwistSeal Mini (40 mm) Manifold Modules TwistSeal Mini Deluxe (40 mm) Supply / Return Modules c/w Heavy Duty Zone Valve Supply & Balancing Return Stk# The supply module provides on/off manual control to allow isolation of individual loops. The return module permits balancing of the flow rate with flow setting dial. Comes with o-rings TwistSeal Mini Deluxe (40mm) Z.V. Supply & Balancing Return Module Pair 0 pair Radiant Heating & Cooling TwistSeal Mini (40 mm) Multiport Zone Valve Supply & Flow Meter Balancing Return Module Pair 7800 Series The supply module provides on/off manual control to allow isolation of individual loops. The return module permits visual balancing of the flow rate with the flow meter. Comes with o-rings TwistSeal Mini (40mm) 2-port Z.V.Supply & Flow Meter Return Module Pair TwistSeal Mini (40mm) -port Z.V.Supply & Flow Meter Return Module Pair 6 pair 4 pair TwistSeal Mini (40 mm) Multiport Zone Valve Supply & Balancing Return Module Pair 7820 Series The supply module provides on/off manual control to allow isolation of individual loops. The return module permits balancing of the flow rate. Comes with o-rings TwistSeal Mini (40mm) 2-port Z.V.Supply & Flow Bal. Return Module Pair TwistSeal Mini (40mm) -port Z.V.Supply & Flow Bal. Return Module Pair 6 pair 4 pair

16 Heat Link TwistSeal Manifold Accessories Radiant Heating & Cooling PEX Connecters for TwistSeal Manifolds Series Solid brass fitting attaches to the end of the PEX tubing and allows for easy installation onto the bottom of the manifold module. Comes with o-ring " PEX to TwistSeal Manifold Connecter 0 pair " PEX to TwistSeal Manifold Connecter 0 pair " PEX to TwistSeal Manifold Connecter 0 pair " PEX to TwistSeal Manifold Connecter c/w Nut 0 pair PEX Insert Connecters for TwistSeal Manifold 2000 Series Plastic fitting is installed into the bottom of the manifold module and is held in place by the nut. The tubing is then pressed on to this fitting. Comes with o-ring. SS press sleeves sold separately " PEX Insert Manifold Connecter 5 ea " PEX Insert Manifold Connecter c/w Nut 5 ea. 4

17 Heat Link - 4" Stainless Steel Manifolds Common Features: Preassembled configurations from 2 to 2 loops. Integrated " FNPT isolation valves and hosebibs. Zone valve return balancing with manual shut-off; accepts optional actuators. Maximum trunk flow rate: 8 US gpm (4. m /h) 2", 5 8", and 4" PEX connecters available Series Series ( loop model shown with 4 actuators, automatic air vent, 2" plug, port cap, and pressure bypass valve) Model Specific Features: Maximum circuit flow rate:.5 US gpm (0.4 m /h) Balancing supply with 0-.5 US gpm (0-5 L/min) flow meter. Typical Applications: Residential. Small commercial. L to R 2", 5 8", & 4" PEX connecters ( loop model shown with 2 actuators and side mount automatic air vent) Model Specific Features: Maximum circuit flow rate: 2.5 US gpm (0.57m /h) Balancing supply. Typical Applications: Commercial. Snow melting. L to R port cap, 2", 5 8", & 4" PEX connecters # of Loops Recommended Housing* Recessed Surface Mount Tubing Size PEX Connecters / Loop Conduit Elbows / Loop for Wet Installation 2" " " Manifold Series - 4" Stainless Steel (7600 or series) Actuator with LED Actuator with End Switch DDC Actuator *recommended housing based on 90 mains piping

18 Heat Link - 4" Stainless Steel Manifolds Radiant Heating & Cooling - 4" Stainless Steel Manifolds with Flow Meters 7600 Series Manifold includes: assembled flow balancing supply manifold with " FNPT isolation valve and hose bib/air vent. assembled balancing shut-off return manifold with " FNPT isolation valve and hose bib/air vent. 2 mounting brackets. PEX connecters & port caps sold separately Loop SS Manifold with Flow Meters 760 Loop SS Manifold with Flow Meters Loop SS Manifold with Flow Meters Loop SS Manifold with Flow Meters Loop SS Manifold with Flow Meters Loop SS Manifold with Flow Meters Loop SS Manifold with Flow Meters Loop SS Manifold with Flow Meters Loop SS Manifold with Flow Meters 76 Loop SS Manifold with Flow Meters Loop SS Manifold with Flow Meters - 4" High Flow Stainless Steel Manifolds Series Manifold includes: assembled balancing supply manifold with " FNPT isolation valve and hose bib/air vent. assembled balancing shut-off return manifold with " FNPT isolation valve and hose bib/air vent. 2 mounting brackets. PEX connecters & port caps sold separately Loop High Flow SS Manifold 7620 Loop High Flow SS Manifold Loop High Flow SS Manifold Loop High Flow SS Manifold Loop High Flow SS Manifold Loop High Flow SS Manifold Loop High Flow SS Manifold Loop High Flow SS Manifold Loop High Flow SS Manifold 762 Loop High Flow SS Manifold Loop High Flow SS Manifold 6

19 Heat Link - 4" Stainless Steel Manifold Accessories Port Caps for - 4" Stainless Steel Manifolds Stk# 7700 Caps off unused ports on the - 4" Stainless Steel Manifold Port Cap for - 4" SS Manifold 0 pair PEX Connecters for - 4" Stainless Steel Manifolds 7700 Series Solid brass fitting attaches to the end of the PEX tubing and allows for easy installation onto the bottom of the - 4" SS manifold. Comes with o-ring. Radiant Heating & Cooling " PEX to - 4" SS Manifold Connecter 0 pair " PEX to - 4" SS Manifold Connecter 0 pair " PEX to - 4" SS Manifold Connecter 0 pair Coupling for - 4" Stainless Steel Manifold Stk# 7600 Used to connect - 4" SS manifolds together. Comes with o-rings Coupling for SS Manifold 2" Plug for - 4" Stainless Steel Manifold Stk# Plug to seal - 4" SS manifold outlet. Comes with o-ring " Plug for - 4" SS Manifold Automatic Air Vent for - 4" Stainless Steel Manifold Stk# 7692 Add an automatic air vent to the - 4" SS manifold by replacing a valve. Comes with o-ring Automatic Air Vent for - 4" SS Manifold 7

20 Heat Link - 4" Stainless Steel Manifold Accessories Radiant Heating & Cooling Side Mount Automatic Air Vent Set for - 4" Stainless Steel Manifold Stk# 7695 Add an automatic air vent to the - 4" SS manifold without occupying a loop. Comes with o-ring. Side Mount Automatic Air Vent is not compatible with the Pressure Bypass Kit (#7697) Side Mount Automatic Air Vent Set for - 4" SS Manifold Pressure Bypass Kit for - 4" Stainless Steel Manifold Stk# 7697 This valve prevents a steep rise of the pump head and maintains flow at a stable rate. Also ensures only required amount of cir cu lat ing water is used for hydronic systems. The valve can be ad just ed to any point between 0.05 and 0.5 bar (.67 and 6.7 ft H 2 O). Comes with o-rings. Pressure Bypass Kit is not compatible with the Side Mount Automatic Air Vent Set (#7695) Pressure Bypass Kit for - 4" SS Manifold 8

21 Heat Link 2" Stainless Steel Manifold Features: Preassembled configurations from 4 to 4 loops. Ball valve isolation for each loop. - 2" and 2" MNPT open end adapters. Maximum trunk flow rate: 50 US gpm (.4 m /h). Branch pair Cv = ", 4", and " PEX connecters. Radiant Heating & Cooling Typical Applications: Large commercial. Snow melting. Distribution header. ( loop model shown with 2" MNPT Assembly Kit, and 4" PEX connecters) 2" Stainless Steel Manifolds Series Manifold includes: assembled supply manifold with ball valves and hose bib/air vent. assembled return manifold with ball valves and hose bib/air vent. 2 mounting brackets. Assembly Kit and PEX connecters sold separately Loop 2" SS Manifold Loop 2" SS Manifold Loop 2" SS Manifold Loop 2" SS Manifold Loop 2" SS Manifold Loop 2" SS Manifold Loop 2" SS Manifold 766 Loop 2" SS Manifold Loop 2" SS Manifold Loop 2" SS Manifold 9

22 Heat Link 2" Stainless Steel Manifold Accessories Radiant Heating & Cooling Coupling for 2" SS Manifold Stk# Couple 2" SS Manifolds together. Loctite 55 pipe sealing cord is recommended for thread sealing (not included) Coupling for 2" SS Manifold pair Assembly Kits for 2" Stainless Steel Manifold Stk# Series Assembly Kit includes: 2 Closed Ends for 2" SS Manifold with o-ring. 2 Open End Adapters (- 2" or 2" MNPT) for 2" SS Manifold with o-ring. packet of lubricant. New! " MNPT Assembly Kit for 2" SS Manifold New! " MNPT Assembly Kit for 2" SS Manifold PEX Connecters for 2" Stainless Steel Manifold Stk# Series Solid brass fitting attaches to the end of the PEX tubing and allows for easy installation onto the shut-off valves of the 2" SS manifold. Comes with o-ring. " connecters require " SS Press Sleeves (#24228; page 26) and use of a " Press Tool (e.g. 28). New! " PEX to 2" SS Manifold Connecter pair New! " PEX to 2" SS Manifold Connecter pair Special Order* " PEX to 2" SS Manifold Connecter pair " Cap and Washer for 2" Stainless Steel Manifold Stk# Cap to seal 2" SS manifold outlet. New! " Cap and Washer for 2" SS Manifold pair 20 * Check with your local representative for availability.

23 Heat Link Manifold Housings Features & Benefits allows easy access to manifold visible parts made of satin coated steel and are ready to paint without priming cover enables a structural flush seal locking, removable (lift off) door stylish ventilation apertures to prevent build up of heat and formation of condensation openings for mains piping on left & right sides (recessed only) Stk. # Width Height Depth Maximum # of Loops with Manifold Assembly Kit #: 79400* 7940* 79402* Max # of SS Manifold Loops 7400 Series: Surface Mounted Manifold Housing " (60 mm) 0" (762 mm) 5-2" (40 mm) " (762 mm) 0" (762 mm) 5-2" (40 mm) " (067 mm) 0" (762 mm) 5-2" (40 mm) Series: Recessed Manifold Housing " (60 mm) 0-4" (768 mm) 2" (584 mm) 2" (584 mm) - 7 8" (98 mm) - 7 8" (98 mm) " (05 mm) 2" (584 mm) - 7 8" (98 mm) Installation Methods: 2 Allowance for 90 mains piping. 2 Allowance for straight isolation valves. Manifolds only, no piping allowances. * Thermometers must be removed in recessed housing.

24 Heat Link Manifold Housings Radiant Heating & Cooling Manifold Housing: Recessed 7700 Series Allows easy access to the manifold through its locking, removable door. Features: visible parts made of satin coated steel, surfaces ready to paint without priming, and stylish ventilation apertures to prevent build up of heat and formation of condensation. For use with TwistSeal and Stainless Steel Manifolds (7600 and series). Not compatible with 2" Stainless Steel Manifolds (76600 series) Recessed Manifold Housing 24" 2" - 7 8" 770 Recessed Manifold Housing 0" 2" - 7 8" 774 Recessed Manifold Housing 4-2" 2" - 7 8" Manifold Housing: Surface Mount 7400 Series Allows easy access to the manifold through its locking, removable door. Features: made of satin coated steel, surfaces ready to paint without priming, and stylish ventilation apertures to prevent build up of heat and formation of condensation. Skirting by others. For use with TwistSeal and Stainless Steel Manifolds (7600 and series). Not compatible with 2" Stainless Steel Manifolds (76600 series). Special Pricing 7424 Surface Mounted Manifold Housing 24" 0" 5-2" 740 Surface Mounted Manifold Housing 0" 0" 5-2" 7442 Surface Mounted Manifold Housing 42" 0" 5-2" Key Lock for Manifold Housing Door Stk# 7902 Key lock that can field replace the standard coin/screwdriver lock of manifold housings (7700 and 7400 Series) Key Lock for Housing Door 22

25 Heat Link PEX Compression Couplings & Adapters PEX Tubing Compression Couplings Series Solid brass fittings couples PEX tubing to PEX tubing " 8" PEX Comp. Coupling 25 ea " 2" PEX Comp. Coupling 25 ea " 5 8" PEX Comp. Coupling 25 ea " 4" PEX Comp. Coupling 25 ea " " PEX Comp. Coupling 25 ea. Radiant Heating & Cooling PEX Compression to MNPT Adapters Series Solid brass fittings converts PEX tubing to male NPT thread. Note: When used with PEX tubing there is a risk of thermal expansion / contraction due to temperature fluctuation. It is recommended that a swing joint or expansion loop is installed at the high temp (supply) end of the tubing " PEX Comp. 2" MNPT Adapter 25 ea " PEX Comp. 2" MNPT Adapter 25 ea " PEX Comp. x 4" MNPT Adapter 25 ea " PEX Comp. 4" MNPT Adapter 25 ea " PEX Comp. " MNPT Adapter 25 ea. 2

26 Heat Link PEX Compression Adapters Radiant Heating & Cooling PEX Compression to 90 Female Sweat Elbows 6700 & Series Solid brass fittings converts PEX tubing to female copper pipe. Ideal for baseboard connections " PEX Comp. 2" F/Sweat 90 Elbow 25 ea " PEX Comp. 4" F/Sweat 90 Elbow 25 ea " PEX Comp. 4" F/Sweat 90 Elbow 25 ea. PEX Compression to Female Sweat Adapters 6700 & Series Solid brass fittings converts PEX tubing to female copper pipe " PEX Comp. 2" F/Sweat Adapter 25 ea " PEX Comp. 4" Straight F/Sweat Adapter 25 ea " PEX Comp. 4" F/Sweat Adapter 25 ea. PEX Compression to Male Sweat Adapters Series Solid brass fittings converts PEX tubing to male copper pipe " PEX Comp. 2" M/Sweat Adapter 25 ea " PEX Comp. 4" M/Sweat Adapter 25 ea " PEX Comp. 4" M/Sweat Adapter 25 ea. Note: For 2", 4", ", - 4", and - 2" PEX tubing the SS press sleeve fitting system can be used, see the Potable Water System section. 24

27 Heat Link 2-way Injection Mixing Primary Supply Radiant Heating & Cooling Secondary Supply 4 2 Primary Return Secondary Return Components HeatLink Injection Valve (62000 series; page ) 2 HeatLink Balancing Valve (#6225; page 2) Secondary Pump 4 HeatLink Pressure Activated Bypass Valve (60000 series; page 4) Control Options Setpoint 5 HeatLink Thermostatic Head with Capillary (#57094; page 6) Setpoint or Outdoor Reset 6 HeatLink Compact Mixing Reset Control (#55; page 44) 7 HeatLink 24Vac DPDT Pump Relay (#452; page 42) 8 HeatLink DDC Actuator (#562; page 7) Note: Not all required components are shown. Local codes, regulation, and authorities have final jurisdiction. 25

28 Heat Link -way Compact Mixing System Radiant Heating & Cooling Primary Supply Secondary Supply 2 Primary Return Secondary Return Components HeatLink Compact -way Mixing Valve (6700 series; page ) 2 Secondary Pump HeatLink Pressure Activated Bypass Valve (60000 series; page 4) MECHANICAL ROOM IN A BOX Control Options Setpoint 4 HeatLink Thermostatic Head with Capillary (#57094; page 6) Setpoint or Outdoor Reset 5 HeatLink Compact Mixing Reset Control (#55; page 44) 6 HeatLink 24Vac DPDT Pump Relay (#452; page 42) 7 HeatLink DDC Actuator (#562; page 7) Panel Alternatives TMP series - pages TWH series - pages CDP series - pages SSTS series - pages Note: Not all required components are shown. Local codes, regulation, and authorities have final jurisdiction. 26

29 Heat Link -way Mixing System Primary Supply Radiant Heating & Cooling Secondary Supply 2 Primary Return Secondary Return Components HeatLink -way Mixing Valve (6500 series; page 0) 2 Secondary Pump HeatLink Pressure Activated Bypass Valve (60000 series; page 4) Control Options Setpoint or Outdoor Reset 4 HeatLink Compact Mixing Reset Control (#55; page 44) 5 HeatLink 24Vac DPDT Pump Relay (#452; page 42) 6 HeatLink Mixing Valve Motor (5800 series; page 5) Snow melt (not shown) HeatLink Snow/Ice Detector & Melting Control (#667; page 45) HeatLink Snow/Ice Detector (#0090, 009; page 45) 6 HeatLink Mixing Valve Motor (5800 series; page 5) MECHANICAL ROOM IN A BOX Panel Alternatives CDP0R - pages SSTL series - pages SMP series - pages 08-6 Note: Not all required components are shown. Local codes, regulation, and authorities have final jurisdiction. 27

30 Heat Link 4-way Mixing System Radiant Heating & Cooling Secondary Supply Primary Supply 2 Secondary Return Primary Return Components HeatLink 4-way Mixing Valve (64000 series; page 0) 2 Secondary Pump HeatLink Pressure Activated Bypass Valve (60000 series; page 4) Control Options Setpoint or Outdoor Reset 4 HeatLink Compact Mixing Reset Control (#55; page 44) 5 HeatLink 24Vac DPDT Pump Relay (#452; page 42) 6 HeatLink Mixing Valve Motor (5800 series; page 5) Snow melt (not shown) HeatLink Snow/Ice Detector & Melting Control (#667; page 45) HeatLink Snow/Ice Detector (#0090, 009; page 45) 6 HeatLink Mixing Valve Motor (5800 series; page 5) Note: Not all required components are shown. Local codes, regulation, and authorities have final jurisdiction. 28

31 Heat Link Mixing Valves 4-way FNPT Mixing Valves Series This unit mixes high temperature boiler water with heating return water to create a supply water temperature. It has the option of manual op er a tion, or it can be fitted with a Mixing Valve Motor for " to 2" FNPT Valves -Point Floating (#58; page 5) or Mixing Valve Motor for " to 2" FNPT Valves DDC (#582; page 5) for fully automatic operation. " Cv =.7 (Kvs = 0) - 4" Cv = 8.7 (Kvs = 6) - 2" Cv = 29. (Kvs = 25) 2" Cv = 46.8 (Kvs = 40) New! " 4-way FNPT Mixing Valve New! 640-4" 4-way FNPT Mixing Valve New! " 4-way FNPT Mixing Valve New! " 4-way FNPT Mixing Valve Radiant Heating & Cooling 4-Way Flange Mixing Valves 6400 Series This unit mixes high temperature boiler water with heating return water to create a supply water temperature. It has the option of manual op er a tion, or it can be fitted with a Mixing Valve Motor for 2" to 4" Flange Valves -Point Floating (#58200; page 5) or Mixing Valve Motor for 2" to 4" Flange Valves DDC (#5800; page 5) for fully automatic operation. Flange are DIN compatible. 2" Cv = 69.4 (Kvs = 60) 2-2" Cv = 04.0 (Kvs = 90) " Cv = 7.4 (Kvs = 50) 4" Cv = 260. (Kvs = 225) New! " 4-way Flange Mixing Valve New! " 4-way Flange Mixing Valve New! 648 " 4-way Flange Mixing Valve New! " 4-way Flange Mixing Valve 29

32 Heat Link Mixing Valves Radiant Heating & Cooling 4-way FNPT Mixing Valves Series This unit mixes high temperature boiler water with heating return water to create a supply water temperature. It has the option of manual op er a tion, or it can be fitted with a Mixing Valve Motor for " and - 4" Valves (#580; page 5) for fully automatic operation. - 4" Cv = 7.4 (Kvs = 5) WSL " 4-way FNPT Mixing Valve 4-Way Flange Mixing Valves 6400 Series This unit mixes high temperature boiler water with heating return water to create a supply water temperature. It has the option of manual op er a tion, or it can be fitted with a mixing valve motor (#5899; page 5) for fully automatic operation. Flanges are ANSI and DIN compatible. 2-2" Cv = 7. (Kvs = 6) " Cv = 6. (Kvs = 00) WSL " 4-way Flange Mixing Valve WSL 6480 " 4-way Flange Mixing Valve -way FNPT Mixing / Diverting Valves 6500 Series This unit mixes high temperature boiler water with heating return water to create a supply water temperature. It has the option of manual op er a tion, or it can be fitted with a Mixing Valve Motor for " to 2" FNPT Valves -Point Floating (#58; page 5) or Mixing Valve Motor for " to 2" FNPT Valves DDC (#582; page 5) for fully automatic operation. " Cv =.7 (Kvs = 0) - 4" Cv = 8.7 (Kvs = 6) - 2" Cv = 29. (Kvs = 25) 2" Cv = 46.8 (Kvs = 40) New! 6026 " -way FNPT Mixing / Diverting Valve New! 659-4" -way FNPT Mixing / Diverting Valve New! 654-2" -way FNPT Mixing / Diverting Valve New! 655 2" -way FNPT Mixing / Diverting Valve 0

33 Heat Link Mixing Valves Compact -Way Mixing Valves 6700 Series Three-way mixing valve for fluid temperature control in heating and cooling systems. Bronze valve body with brass nipples, protective cap, and stainless spindle with double O-ring seal. Threads are compatible with actuators (#5620, #562, #562; page 7) and thermostatic heads (#5709 and #57094; page 6). 2" Cv = 2.9 (Kv = 2.5) 4" Cv = 4. (Kv =.5) " Cv = 5. (Kv = 4.6) - 4" Cv = 7.4 (Kv = 6.4) 676 2" Compact -way Mixing Valve " Compact -way Mixing Valve 6725 " Compact -way Mixing Valve 672-4" Compact -way Mixing Valve Radiant Heating & Cooling " -Way Diverter Valve Stk# 6025 Provides on/off or modulated flow control with bypass for man i folds or mis cel la ne ous sup ple men tal heating units. Fitted with three " sweat unions. Threads are compatible with actuators (#5620, #562, #562; page 7) and thermostatic heads (#5709 and #57094; page 6). Cv = 6.0 (Kv = 5.2) WSL 6025 " -way Mixing/Diverting Valve

34 Heat Link Valves Radiant Heating & Cooling Straight Balancing Valve " Female Sweat Stk# 6225 Flow balancing valve for use in injection systems and with the side stream filter Straight Balancing Valve " F/Sweat 24 ea. 90 Angle Radiator Valves 6200 Series Provides on/off or modulated flow control for miscellaneous supplemental heating units (e.g. towel warmers). Nickel plated. Threads are compatible with actuators (#5620, #562, #562; page 7) and thermostatic heads (#5709 and #57094; page 6). 2" Cv =.6 (Kv =.5) 4" Cv = 2.9 (Kv = 2.5) Angle Radiator Valve 2", Nickel Plated 5 ea Angle Radiator Valve 4", Nickel Plated 20 ea. Straight Radiator Valves Series Provides on/off or modulated flow control for miscellaneous sup ple men tal heating units (e.g. towel warmers). Nickel plated. Threads are compatible with actuators (#5620, #562, #562; page 7) and thermostatic heads (#5709 and #57094; page 6). 2" Cv =.6 (Kv =.5) 4" Cv = 2.9 (Kv = 2.5) 6226 Straight Radiator Valve 2", Nickel Plated 20 ea Straight Radiator Valve 4", Nickel Plated 20 ea. 2

35 Heat Link Valves Straight Zone Valves/Injection Valves Series Provides on/off or modulated flow control for baseboard, fan coils, manifolds, and injection controls. Threads are compatible with actuators (#5620, #562, #562; page 7) and thermostatic heads (#5709 and #57094; page 6). 2" Cv = 2.9 (Kv = 2.5) 4" Cv = 4.2 (Kv =.6) " Cv = 4.9 (Kv = 4.2) - 4" Cv = 6.8 (Kv = 5.8) 6206 Straight Zone Valve 2" NPT 5 ea Straight Zone Valve 4" NPT 5 ea Straight Zone Valve " NPT 6200 Straight Zone Valve - 4" NPT Radiant Heating & Cooling 2" Straight Return Connecter Stk# 606 Provides balancing for miscellaneous sup ple men tal heating units (e.g. towel warmers). Gives a clean exposed finish when used with the HeatLink zone valves in supplemental heat applications. Nickel plated. Cv =.6 (Kv =.5) 606 Straight Return Connecter 2" 20 ea. 2" 90 Angle Return Connecter Stk# 66 Provides balancing for miscellaneous sup ple men tal heating units (e.g. towel warmers). Gives a clean exposed finish when used with the HeatLink zone valves in supplemental heat applications. Nickel plated. Cv =.6 (Kv =.5) Angle Return Connecter 2" 5 ea.

36 Heat Link Valves Radiant Heating & Cooling Pressure Activated Bypass Valve Series This valve prevents a steep rise of the pump head and maintains flow at a stable rate. Also ensures only required amount of cir cu lat ing water is used for hydronic systems. The 4" valve can be ad just ed to any point between.5 and 7 ft H 2 O (50 and 500 mbar). The " and - 4" can be adjusted to any point between 0 and 60 ft H 2 O (0 and 800 mbar). 4" max. flow = US gpm (2950 L/h) " max. flow = 22 US gpm (5000 L/h) - 4" max. flow = 5 US gpm (7950 L/h) Pressure Activated Bypass Valve 4" 5 ea Pressure Activated Bypass Valves " 5 ea Pressure Activated Bypass Valves - 4" 5 ea. 4

37 Heat Link Mixing Valve Motors Mixing Valve Motor for " & - 4" Valves Stk# 580 Used to automatically operate the 4-way mixing valve. The motor is reversible and is provided with fixed limit switches. For use with - 4" mixing valves (#6400; page 0). 24 Vac 50/60 Hz 2 VA WSL 580 Mixing Valve Motor for " and - 4" Valves Mixing Valve Motors for " to 2" Rotary NPT Valves Stk# 58 & 582 Radiant Heating & Cooling Used to automatically operate the 4-way or -way mixing valve. For use with 4-way FNPT mixing valves (#64026, #640, #6404, #6405; page 29) and -way FNPT mixing / diverting valves (#6026, #659, #654, #655; page 0. #58 motor is floating -point action mixing valve motor. 24 Vac 50/60 Hz 2 VA #582 motor is DDC mixing valve motor. 24 Vac/dc 50/60 Hz 4 VA New! 58 Mixing Valve Motor for " to 2" FNPT Valves -Point Floating New! 582 Mixing Valve Motor for " to 2" FNPT Valves DDC Mixing Valve Motors for 2-2" to 4" Flange Mixing Valves Stk# 5899 Used to automatically operate the 4-way flange mixing valve. The motor is re vers ible and is provided with fixed limit switches. For use with flanged 2-2" and " mixing valves (#6465 and #6480; page 0). 24 Vac 50/60 Hz 2 VA WSL 5899 Mixing Valve Motor for 2-2" to 4" Flange Mixing Valves New! New! 5800 Mixing Valve Motors for 2" to 4" Flange Mixing Valves Stk# & 5800 Used to automatically operate the 4-way flange mixing valve. For use with flanged 2" to 4" mixing valves (#6464, #6466, #648, #65000; page 29). #58200 motor is floating -point action mixing valve motor. 24 Vac 50/60 Hz 2 VA #5800 motor is DDC mixing valve motor. 24 Vac/dc 50/60 Hz 5 VA Mixing Valve Motor for 2" to 4" Flange Mixing Valves -Point Floating Mixing Valve Motor for 2" to 4" Flange Mixing Valves DDC 5

38 Heat Link Thermostatic Heads Radiant Heating & Cooling Thermostatic Head Stk# 5709 Thermostatic head for HeatLink zone valves. Maximum setting 84 F (29 C). Senses 0.4 F (0.2 C) air temperature change. Takes 24 minutes to close from full open Thermostatic Head (6-28 C) Thermostatic Head with 6' (.8 m) Remote Cap il lary Stk# Used as injection control for HeatLink zone valves. Senses 0.4 F (0.2 C) supply water change. Takes 5 minutes to close from full open. Temperature adjustment range: F (6-66 C) Thermostatic Head c/w Capillary (86-49 F) 6

39 Heat Link Actuators 5620/ 5622 Actuators c/w End Switch 5620 Series These motors allow for additional room temperature control in con junc tion with a room thermostat by mounting on a TwistSeal supply man i fold module (5620), Stainless Steel Manifold (562), HeatLink & 6000 series zone valves (562), or TwistSeal Multiport Manifold (5622). Comes complete with end switch to allow pump and/or boiler switching HeatLink TwistSeal Manifold Actuator c/w End Switch 00 ea. 562 HeatLink Valve & SS Manifold Actuator c/w End Switch 00 ea HeatLink Multiport Manifold Actuator c/w End Switch 00 ea. Radiant Heating & Cooling 56200/ Actuators Series These actuators allow for additional room temperature control in con junc tion with a room thermostat by mounting on a TwistSeal supply man i fold module (56200), Stainless Steel Manifold (5620), HeatLink & 6000 series zone valves (5620), or TwistSeal Multiport Manifold (56202). Includes a heat demand LED indicator HeatLink TwistSeal Manifold Actuator with LED 00 ea HeatLink Valve & SS Manifold Actuator with LED 00 ea HeatLink Multiport Manifold Actuator with LED 00 ea. How to tell the 562x0 and 562x actuators apart Actuator LED End Switch Female Thread Center Pin Mounts on Yes No Fine Yes TwistSeal & Yes No Coarse No Valves & SS manifolds 5620 No Yes Fine Yes TwistSeal & No Yes Coarse No Valves & SS manifolds / / 562 DDC Actuator Stk# 562 These actuators allow for additional room temperature control when used in conjunction with a direct digital control system by mounting on a Stainless Steel Manifold, or HeatLink & 6000 series zone valves. 562 HeatLink DDC Actuator for Manifolds and Valves 00 ea. 7

40 Stat Link Electronic Control System HeatLink did some simple addition, and came up with a significant innovation. By adding an LED on our new StatLink zone drive actuator, HeatLink has reduced the waiting time. The LED immediately indicates heat demand. Along with our new thermostats and zone modules, the result is a completely visual feedback system. To sum it up, it s situation normal at-a-glance. We ve also gone color-coded and digital. Of the five thermostats StatLink now offers, one is mechanical, one is electronic, and three are digital. The manual or automatic setback on the electronic and digital thermostats, provide energy savings by lowering the temperature of unoccupied rooms. All thermostats are designed for use with standard AWG 8 cable. Our screw terminals are color-coded to match the wire colors found in fire-alarm cable (FAS05). Our StatLink modules simplify the whole wiring process, and eliminate that tangled mess of wires. The color-coded screw terminals indicate where each wire goes in the heating zones. Each zone has an LED indicator for heat demand, and up to 4 actuators can be connected to each zone. It also acts as a combined end-switch for all zones, by activating the boiler and pump when heat is required. HeatLink s new StatLink system saves the contractor both time and money, by focusing on ease of installation and ease of use. The new StatLink is a welcome addition to the HeatLink family, and our customers will find it is an excellent fit with our other product lines. Electronic Thermostat #4644 analog electronic regulation heat demand LED large, easy to adjust dial position operation selector switch: heat, manual or automatic (external timer) setback setback of 4 C (7 F) or 4 wire operation internal or external sensor operation Dual Dry Contacts Digital Thermostat #46544 proportional integral temperature regulation fully menu driven large digital display manual or automatic (external timer) setback adjustable setback temperature room, floor or combined sensor operation adjustable characteristics for system optimization (high mass, low mass, baseboard, fan coil and cooling) external sensor 24Vac Power

41 Digital Timer Thermostat #4664 proportional integral temperature regulation fully menu driven large digital display easy to program 7 day 24 hour timer with 4 user programs and 9 fixed programs room, floor or combined sensor operation setback signal feedback to StatLink ITCS function for intelligent setback functionality adjustable characteristics for system optimization (high mass, low mass, baseboard, fan coil and cooling) Digital Heat/Cool Timer Thermostat #4667 proportional integral temperature regulation fully menu driven large digital display easy to program 7 day 24 hour timer with 4 user programs and 9 fixed programs room, floor or combined sensor operation setback signal feedback to StatLink ITCS function for intelligent setback functionality adjustable characteristics for system optimization (high mass, low mass, baseboard, fan coil and cooling) heat, cool, fan, or automatic operation cooling contacts StatLink 6 Zone Base Module - # Vac input boiler and pump switching via dual dry contacts heat demand LEDs for each zone up to 4 actuators per zone max. 2 actuators with the addition of a 60VA transformer StatLink 4 Zone Expansion Module - #4024 (not shown) easy addition of 4 zones heat demand LEDs for each zone up to 4 actuators per zone Actuators #56200 Series heat demand LED indicator available with endswitch StatLink 2 Zone Heavy Duty Expansion Module - #40242 easy addition of 2 zones heat demand LEDs for each zone up to 2 actuators per zone

42 Heat Link Thermostats Radiant Heating & Cooling Electronic Thermostat Stk# 4644 Provides analog electronic temperature regulation. Screw terminal connection for use with standard thermostat wire. position operation selector switch: heat, manual or automatic (external timer) setback. Includes heat demand LED. Optional external sensor HeatLink Electronic Thermostat with LED and Setback Selector Switch Digital Thermostat Stk# Provides proportional integral temperature regulation. Screw terminal connection for use with standard thermostat wire. Adjustable manual or automatic (external timer) setback. Features a fully menu driven large backlit digital display. Offers optimization for various system types (high mass, low mass, baseboard, fan coil and cooling). Optional external sensor HeatLink Digital Thermostat "new design" Digital Timer Thermostat Stk# 4664 Provides proportional integral temperature regulation for maximum comfort and efficiency. Features a fully menu driven large digital display. Offers optimization for various system types (high mass, low mass, baseboard, fan coil and cooling). Take control with the easy to program 7 day 24 hour timer utilizing 9 preset programs and the ability to program 4 additional user programs. This thermostat is capable of generating a setback signal that can be best utilized with a StatLink module and shared with other thermostats. Optional external sensor HeatLink Digital Timer Thermostat Digital Heat/Cool Timer Thermostat Stk# 4667 Provides all the functionality of the Digital Timer Thermostat (#4664) plus cooling and fan control. Operational modes consist of: heat, cool, fan, or automatic. Optional external sensor HeatLink Digital Heat/Cool Timer Thermostat 40

43 Stat Link You re in Control because every family has different needs, and every home is unique. A traditional forced air system with one central thermostat may need to be set higher than necessary to ensure that some parts of the house get sufficient heat. With HeatLink radiant floor heating, a house can be divided into different heating zones. Each zone will have it s own thermostat that will set it s temperature independently from the other zones. This means that you can heat only the rooms that need heat. Rooms that don t need to be heated can be put into setback, a lower user adjustable temperature, to save energy. Bedroom #2 Den Living Room Kitchen Master Bedroom Add a timer thermostat to automatically switch between normal operation and setback operation on a set schedule. This schedule will let you automatically lower the temperature of your home when no one s home and bring the temperature back up to greet you upon your return. Dining Room Garage Example: Living area is heated in the morning and evening, and setback during the day and at night. Bedrooms are heated during the night, and setback during the day. Less frequently used rooms can be manually switched to and from setback mode. Setback Channel - Living Area Normal operation Setback operation Setback Channel 2 - Bedrooms Normal operation Setback operation 24 hour schedule

44 Heat Link 24V AC Relay Radiant Heating & Cooling 24Vac DPDT Pump Relay Stk# 4502 Double pole double throw relay used for pump and/or boiler control. Use with socket #4502 sold separately. Contacts: 0A resistive, 7.5A 0 Vac, 4 hp. 7.5A resistive, 5.0A 220 Vac, hp Vac DPDT Pump Relay 24Vac DPDT Pump Relay Socket Stk# 4502 Socket for 24V AC DPDT pump relay #4502. Easily mounted on DIN rail Pin Round Socket for AC Relay 24Vac DPDT Pump Relay Box Stk# 452 Electrical enclosure complete with #4502 relay, #4502 socket, and DIN rail. Contacts: 0A resistive, 7.5A 0 Vac, 4 hp. 7.5A resistive, 5.0A 220 Vac, hp. 452 HeatLink 24Vac DPDT Pump Relay Box 42

45 Heat Link StatLink Modules StatLink 6 Zone Base Module Stk# The StatLink 6 zone base module is complete with all the main electrical connections for a hydronic floor heating system. This module can be mounted either on a DIN rail or directly to a wall. It connects room thermostats to their corresponding actuators. Each zone has an LED which indicates if it is calling for heat. A timer thermostat (#4664 or #4667) can send a setback signal to other thermostats via terminal Clock or 2. As soon as there is a heat demand from one zone, a relay with two dry contacts is switched on (Pump, Boiler ). Add more zones by plugging in the #4024 or #40242 module. The 6 zone base module has a current rating of 2.5A; a 60VA transformer allows for 20 actuators per base module to be connected with up to 4 actuators per zone. Radiant Heating & Cooling StatLink 6 Zone Base Module StatLink 4 Zone Expansion Module Stk# 4024 The StatLink 4 zone expansion module connects to the StatLink 6 zone base module, allowing 4 more room thermostats to connect to their corresponding actuators. The 4 zone expansion module has a current rating of 2.5A StatLink 4 Zone Expansion Module StatLink 2 Zone Heavy Duty Expansion Module Stk# The StatLink 2 zone heavy duty expansion module connects to the StatLink 6 zone base module or power module, allowing 2 more room thermostats to connect to up to 2 actuators each. Note: max. 60 VA transformer allows for up to 20 actuators. The 2 zone heavy duty expansion module has a current rating of 2.5A StatLink 2 HD Zone Expansion Module Installation Track for StatLink Modules Stk# 4425 Allows for easy and fast installation of all control modules. Length = 25" 4425 StatLink Installation Track, 25" 4

46 Heat Link Controls Radiant Heating & Cooling HeatLink One Stage Setpoint Control Stk# 050 One stage SPDT heating and cooling setpoint control. Pulse width modulation or bang-bang operation. Features adjustable differential and adjustable delay or cycle. universal sensor is included. 24 Vac 50/60 Hz VA 050 One Stage Setpoint Control HeatLink Compact Mixing Reset Control Stk# 55 The 55 Compact Mixing Reset Control regulates the supply water temperature of an automated mixing valve in order to provide outdoor reset or setpoint operation. The 55 provides a floating action (-way or 4-way mixing) or a 0/2 0 Vdc (2-way injection) signal to adjust the mixing valve position. The 55 also includes two separate night setback channels. Outdoor sensor and universal sensor are included. 24Vac 50/60 Hz 50 VA (max) 55 HeatLink Compact Mixing Reset Control 44

47 Heat Link Controls HeatLink Snow/Ice Detector & Melting Control - Floating Action / Variable Speed Stk# 667 The 667 Snow/Ice Detector & Melting Control is designed to control a single zone snow melting system. The snow melting system may be started manually or automatically through the use of a Snow/Ice Sensor (#0090). The control automatically adjusts the mixed supply water to the snow melting system by controlling a variable speed pump or floating action mixing valve. The 667 control includes a large Liquid Crystal Display (LCD) in order to view system status and operating information. Outdoor sensor and 2 universal sensors are included. 20 Vac 50/60 Hz 600 VA Radiant Heating & Cooling 667 HeatLink Snow/Ice Detector & Melt Control Snow/Ice Detector (Sensor) Stk# 0090, 009 This snow/ice sensor in conjunction with the 667, ac ti vates and con trols a snow melting system based on moisture (snow/ice) and slab tem per a ture. This control is not designed as a simple de tec tion device and will not operate properly in an unheated slab Snow/Ice Sensor (0K) 65 ft cable 009 Snow/Ice Sensor Socket 45

48 Heat Link Sensors Radiant Heating & Cooling Universal Sensor Stk# 007 Standard sensor for use as optional sensor in 0000 series controls. 007 Universal Sensor (0K) 0 ea. Slab Sensor - PVC Sleeve Stk# 0072, 007 Sensors for use in measuring slab or ground temperatures. The 0072 and 007 standard sensors with PVC sleeve are designed for use in soil or concrete. For use with 0000 series controls and series thermostats Slab Sensor (0K) PVC Sleeve 20ft Cable 007 Slab Sensor (0K) PVC Sleeve 40ft Cable Slab Sensor - Stainless Steel Sleeve Stk# 0079 Sensors for use in measuring slab or ground temperatures. The 0079 sensor with stainless steel sleeve is designed for use in concrete, thin-set and grout. For use with 0000 series controls and series thermostats Slab Sensor (0K) SS Sleeve 0ft Cable Indoor Sensors Stk# 0076, 0077 These 0k sensors provide accurate measurement of the indoor air tem per a ture. The 0076 sensor can be mounted directly on the wall using two #6 - " screws. The 0077 sensor can be mounted flush onto a stan dard duplex electrical box. For use with 0000 series controls Indoor Sensor (0K) Small Enclosure 0077 Indoor Sensor (0K) Flush Mount 46

49 Heat Link Controls New! HeatLink Snow Melt Control - DDC Stk# ETO2SMCNTR The ETO2SMCNTR Snow Melt Control is designed to control a one or two zone snow melting system. The snow melting system may be started manually or automatically through the use of a Driveway Sensor (#DRVWSNS-SS). The control automatically adjusts the mixed supply water to the snow melting system by controlling a DDC Mixing Valve Motor (#582 or #5800; sold separately). The control includes a Liquid Crystal Display (LCD) in order to view system status and operating information. Sensor NTC 2K and Driveway Sensor sold separately. 20 Vac 50/60 Hz ETO2SMCNTR Snowmelt Control - DDC ( or 2-Zone Snowmelting Sensor Sold Separately) Radiant Heating & Cooling Sensor NTC 2K Stk# ETF899ASNS Standard sensor for use as optional sensor with ETO2SMCNTR control. New! ETF899ASNS Sensor NTC 2K Snow/Ice Detector (Sensor) Stk# DRVWSNS-SS This snow/ice sensor in conjunction with the ETO2SMCNTR, ac ti vates and con trols a snow melting system based on moisture (snow/ice) and slab tem per a ture. DRVWSNS-SS Driveway Sensor for SMP Panels 47

50 Heat Link Wet System Radiant Heating & Cooling Wall Stud Drywall Baseboard Tubing Tracking on Subfloor Installed on top of the subfloor with light weight concrete. Double Plating Floor Joist Floor Covering Support Beam Foil-backed Insulation Foundation or Main Floor Bearing Wall Gypsum or Concrete HeatLink Tubing Tracking (page 5) HeatLink O 2 Barrier PEX Tubing (page 5) Plywood Subfloor Drywall Tubing Tracking on Subfloor Installed on top of the subfloor with light weight concrete (shown with sleepers for hardwood installation). Baseboard Wall Stud Double Plating Floor Joist Support Beam Hardwood Floor Foil-backed Insulation Subfloor Gypsum or Concrete Foundation or Main Floor Bearing Wall HeatLink O 2 Barrier PEX Tubing (page 5) Preliminary Subfloor HeatLink Tubing Tracking (page 5) 48

51 Heat Link Wet System Tubing Tracking on Insulation Used for basements or slab-on-grade homes. The PEX tubing is encased in a concrete topping. Radiant Heating & Cooling Foundation Thermal Break Footing HeatLink O 2 Barrier PEX Tubing (page 5) Floor Covering Gypsum or Concrete HeatLink Tubing Tracking (page 5) with Track Staples (page 54) Closed Cell High Density Insulation Vapor Barrier Gravel Bed Subsoil Tie Strap on Mesh/Rebar Used for basements or slab-on-grade homes. The PEX tubing is encased in a concrete topping. Foundation Thermal Break Footing HeatLink O 2 Barrier PEX Tubing (page 5) with Tie Straps (page 54) Floor Covering Gypsum or Concrete Closed Cell High Density Insulation Vapor Barrier Gravel Bed Subsoil 49

52 Heat Link DryAbove System Dry system that eliminates the pain in the neck of overhead work No structural changes required Ideal for retrofits or remodeling Inexpensive components keep material costs low 4 DryAbove components: EndBend 4 2 SpacerClip Heat Transfer Plate 4 2 PEX Tubing 2 2 2

53 Heat Link DryAbove System Double Counter Flow Installed on top of the subfloor or existing floors for remodelling or additions. Wall Stud Drywall Baseboard Plating EndBend (page 5) SpacerClip (page 5) HeatLink Heat Transfer Plate (page 5) HeatLink 2" Non Barrier PEX Tubing (page 7) Sleepers Perimeter Edging Radiant Heating & Cooling Subfloor Floor Joist Floor Covering Support Beam Foil-backed Insulation Foundation or Main Floor Bearing Wall EndBend (page 5) SpacerClip (page 5) Wall Stud Drywall Baseboard Plating Subfloor Floor Joist Floor Covering Support Beam Foil-backed Insulation Foundation or Main Floor Bearing Wall HeatLink Heat Transfer Plate (page 5) HeatLink 2" Non Barrier PEX Tubing (page 7) Sleepers Perimeter Edging Serpentine Installed on top of the subfloor or existing floors for remodelling or additions with solid hardwood floors. 5

54 Heat Link DryBelow System Radiant Heating & Cooling Double Loop Installed between 2"/6" O.C. floor joists beneath the subfloor for retrofits or upper floors. Wall Stud Sill Floor Covering Plywood Subfloor Foundation or Main Floor Bearing Wall 2" / 6" O.C. Joist Space HeatLink Heat Transfer Plates (page 5) Reflective Insulation HeatLink Non Barrier PEX Tubing (page 7) Triple Loop Installed between 6"/24" O.C. floor joists beneath the subfloor for retrofits or upper floors. Floor Covering Plywood Subfloor 6" / 24" O.C. Joist Space HeatLink Heat Transfer Plates (page 5) Reflective Insulation HeatLink Non Barrier PEX Tubing (page 7) 52

55 Heat Link Floor Heating Accessories Aluminum Heat Transfer Plate Stk# This plating is used to provide a direct transfer and heat dis tri bu tion from the PEX piping to a wooden subfloor. They can be stapled to the underside of the subfloor in a DryBelow system or used above the subfloor in a DryAbove system. End to end gaps between plates should be from " to 6" (75 to 50mm). Plates measure 24" 4-4" (60 mm 08 mm) " Aluminum Heat Transfer Plate for DryAbove / DryBelow Systems ea. Radiant Heating & Cooling EndBend for DryAbove System Stk# The EndBend allows for transition on the loop ends as well as supports for supply & return piping EndBend for DryAbove System ea. SpacerClip for DryAbove System Stk# 8705 The SpacerClip is placed between the heat transfer plates and holds the tubing in place. Tubing can be stepped into clip SpacerClip for DryAbove System ea. Tubing Tracking: 8", 2" and 5 8" Stk# Tracking provides even tubing spacing and exact reg u la tion of tubing heights. They can be fastened to many surfaces, such as concrete or plywood subfloors, steel Q deck ing, and polystyrene in su la tion. Built in sup ports permit spacing in " (75 mm) multiples. Tracking comes in 4 ft (.22 m) lengths Tubing Tracking ft. 5

56 Heat Link Floor Heating Accessories Radiant Heating & Cooling Track Staples Stk# 8900 Staples are used to fasten tubing tracking to polystyrene insulation. The hooks on the ends ensure the staple will not loosen prior to topping pour Track Staples 8 bag Staples for Stand-up Stapler Series Staples for fastening up to 2" (or 8mm O.D.) PEX tubing to polystyrene insulation. For use with Stand-up Stapler #0220 (discontinued) " (50mm) HeatLink Staples for Stand-up Stapler 6 box " (60mm) Staples for Stand-up Stapler 2 box Staples for Deluxe Staple Gun Series Staples for fastening up to 5 8" (or 20mm O.D.) PEX tubing to polystyrene insulation. For use with HeatLink Deluxe Staple Gun #020 (page 4) " Staples for HeatLink Deluxe Staple Gun 20 box " Staples for HeatLink Deluxe Staple Gun box HeatLink Tie Straps 8900 Series Used to fasten piping to wire mesh or rebar. 5-2" (40 mm) tie wraps (8905) are used for smaller diameter tubing. 7-2" (90 mm) tie wraps (8907) can be used for sizes up to " Tie Straps - 5.5" 0 bag Tie Straps - 7.5" 0 bag 54

57 Heat Link Floor Heating Accessories Expansion Stripping Stk# This foam stripping provides expansion joint and sound barrier at the edge of the floor slab. Roll of 75 ft (2 m) ft Roll Expansion Stripping 7 roll Conduit Elbows Series Radiant Heating & Cooling High impact strength moulded plastic 90 long radius elbow, designed to direct and protect heating tubing in transition area where tubing enters and exits concrete slab " Conduit 90's 00 ea " Conduit 90's 50 ea " Conduit 90's 40 ea " Conduit 90's 00 ea. Plastic Bend Support 8600 Series Allows for easy bending support and removal Plastic Bend Support for 8" and 2" Tubing ea Plastic Bend Support for 4" Tubing ea. Metal Bend Support Series Allows for easy bending support and removal Metal Bend Support for 2" Tubing ea Metal Bend Support for 5 8" Tubing ea Metal Bend Support for 4" Tubing ea. 55

58 Heat Link Chemicals Radiant Heating & Cooling Molybdate Based Corrosion Inhibitor Stk# 0205 The Molybdate Based Corrosion Inhibitor creates a protective monomolecular film over all internal surfaces of the heating system as the water circulates. The film is an anodic coating which immediately stops corrosive attack of the metallic parts. Molybdate will not harm PEX tubing or the manifolds and it is glycol compatible. Molybdate concentration between ppm is recommended; higher concentrations are not harmful. The Molybdate will act as a preoperational cleaner if a sidestream filter is installed and double the amount of Molybdate required is added. The molybdate concentration should be checked after this procedure. The contents of this L (0.26 US gal) container will treat 82 L (48 US gal) of water. Advantages: low toxicity; non-pollutant; non-staining 0205 L Corrosion Inhibitor (Molybdate Based) bottle Purging Compound (Pre & Post Operational Cleaner) Stk# 0 Purging compound for boilers and closed loop systems. Used as a preoperational cleaner and a post start-up cleaner. The contents of this L (0.26 US gal) container will treat L (9 US gal) of water. Note: After refilling system with fresh water, ensure either a glycol or inhibitor is immediately added. 0 L Purging Compound (Pre & Post Operational Cleaner) bottle Postoperational Filtration Cleaner Stk# 02 Scale conditioning additive. Must be used in conjunction with a sidestream filter. Polymer based additive that promotes movement of precipitate into the filter. System can be cleaned while still in operation. The contents of this L (0.26 US gal) container will treat 000 L (264 US gal) of water. 02 L Postoperational Filtration Cleaner L 56

59 Heat Link Water Testing Molybdenum Test Kit Stk# 0020 Determines the amount of molybdate based corrosion inhibitor in the water. Includes: 50 ml plastic beaker Molybdenum titrating solution Molybdenum buffer solution Mixed indicator solution Note: Chemicals included have expiry dates 0020 Molybdenum Test Kit Radiant Heating & Cooling HeatLink Preventative Maintenance Water Analysis Stk# 0042 Water analysis service provided by HeatLink that tests a water sample for: Glycol Nitrite Inhibitor Molybdate Inhibitor ph Level Conductivity Hardness A water sample of ml (.5-7 fl. oz.) in a clean plastic bottle (e.g. wsb2) is required. Stk# Description Pkg Qty Carton Qty Unit Net List Price / Unit 0042 HeatLink Preventative Maintenance Water Analysis (requires wsb2) #2 Water Sample Bottle w/cap - General Stk# wsb2 Plastic bottle for collecting a water sample. Stk# Description Pkg Qty Carton Qty Unit Net List Price / Unit wsb2 #2 Water Sample Bottle w/cap - General 24 ea. 57

60 Heat Link Side Stream Filter Radiant Heating & Cooling Side Stream Filter Stk# 0225 The HeatLink side stream filter is designed to remove precipitate (suspended solids) from the system fluid. Precipitate can lead to increased wear and tear of components and decreased system efficiency. The 0225 filter (made of reinforced polypropylene) is chemically resistant to propylene & ethylene glycol and both molybdate and nitrite inhibitors. The 55 micron filter cartridge is easily cleaned and reusable, no replacement cartridges are necessary. For use on systems up to 600,000 BTU. One size fits all. " male NPT thread connections " Side Stream Filter 58

61 Heat Link Side Stream Filter Cleans system fluids. Extends life of heating system. Protects o-rings and seals. Maintains system efficiency. The 55 micron filter cartridge is easily cleaned and reused. No replacement cartridges are needed. For use in residential and commercial applications. The 55 micron filter is a column of stacked disks designed to remove precipitates as water passes through. There are no replacement filter cartridges to buy, as the disk system is easily removed, cleaned under a stream of warm water, and simply reinserted. For use on systems up to 600,000 BTU. One size fits all. Components HeatLink Side Stream filter (#0225) 2 Isolation (ball) valve Flow Indicator 4 HeatLink Balancing valve (#6225) 5 Low Temp. System Pump

62 Heat Link Introduction MECHANICAL ROOM IN A BOX Mechanical Room in a Box Making the Complex Simple HeatLink has found a way to make the complex more simple. With the Mechanical Room in a Box, some of the most common components of a radiant hydronic installation (mainly the wiring, pumps, and mixing valves), are installed on a panel with a plug, and boxed with a steel cover. This pre-wired, pre-fabricated, preengineered box is a time and money saving way to add control and consistency to an installation. Plug it in, and presto you ve got play! Features Versatile solutions for simple or complex hydronic heating applications. Pre-fabricated, pre-engineered, pre-wired pre-cise! High quality, reliable and standardized construction. Modular approach for ease of installation. Appliance-like protective steel cover; tamper-resistant. Closed hydronic systems can be extensively zoned. Solar energy sources can be seamlessly added. When properly piped, there is less component cycling and more silence. Advantages Pre-engineered solutions reduce design and quotation time. Reliable (ETL listed, UL 508, CSA standard), exceeds highest quality standards, with multiple test procedures for electrical and mechanical system components. Eliminate on-site design and reduced risk of on-site errors. Known cost; fewer surprises. Reduced installation times; time is money! Trouble-free start-ups every time! Fewer call-backs. Compact and aesthetically pleasing. Easily serviced and replaceable. Covered by a single warranty. 60

63 Heat Link System Panel Selection Page # For use in open system For use in closed system Heat Source Built-in -way Mixing Valve Thermostatic Head Reset Mixing Heat Exchanger DHW Priority Distribution Header Distribution Manifold DHW Branch & Pump High Temp Branch High Temp Pump Nominal Output (MBH) For use with Tankless Water Heater Open System Zoning 24hr Timer for Potable Applications Purge Timer Bypass Function Aux Dry Contacts for Space Heating Aux Dry Contacts for DHW Aux Dry Contacts for High Temp Pump Check Valve Panel Stk# Small House, Garage, Apartments ECOZNP All ECO2ZN4P All V All V All CAD All CAD All ELBP ELBP0TS 70 0 ELBP0TS ELBP ELBP50TS TMP TMP TMP070Z TMP085DP Both TMP200DT Both TWH Primary only TWH070P opt Primary only TWH070XP opt Primary only TWH070Z Primary only TWH070XPZ Primary only HEP025P opt HEP080P opt HEP095P opt WHP0P 90 0 opt Large House CDP200R * * * All CDP220R All CDP250R All CDP250PR All CDP0RPR All CDP0RP4R All Solar SOL Commercial SSM Series 00 SSP Series 02 SSTS Series 04 opt opt SSTL Series 06 opt Snow Melting SMP75SS SMP75SSH SMP75SS-HEX 0 75 SMP00SS-HEX 0 00 SMP00SS-HEX-H 0 65 SMP400D SMP5 4 5 SMP Mechanical Room in a Box * CDP200R2 panel branch and pump can be used for either DHW or high temp, but not both 6

64 Heat Link ECO Boiler Panels ECO Boiler Panels ECO Series ECO2ZN4P Mechanical Room in a Box These panels are designed to work with Weil-McLain ECO boilers. The primary piping matches up to the ECO boiler system supply and return. The cool gray color of the enclosure matches the ECO boiler. The panel has three or four Grundfos UPS5-58 pumps. There is a primary pump, a DHW water pump and one or two heating pumps. The primary and DHW pumps are controlled by the boiler. On the ECO Boiler Panel model, the heating pump is controlled by a thermostat (supplied separately) wired to the boiler. On the ECO Boiler Panel High Capacity model, each heating pump is controlled by a thermostat (supplied separately) wired to the terminal strip on the panel. The water temperature is controlled by the boiler. Panel Components Primary Pump DHW Pump Radiant Pump Radiant 2 Pump (ECO2ZN4P only) Electrical Connection Box 24V Terminal Strip (ECO2ZN4P only) Isolation Valve Panel Enclosure (not shown) Primary Supply Primary Return DHW Supply Radiant Supply Radiant Return Radiant 2 Supply Radiant 2 Return DHW Return ECOZNP ECO2ZN4P Listing cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 26-4"H 9-2"W 7-8"D Nominal panel output 80,000 btu/hr 00,000 btu/hr Nominal flow 6.0 US 5 F ΔT 0.0 US 5 F ΔT Max ambient temperature 20 F (49 C) Min operating temperature 40 F (4 C) Max operating temperature 200 F (9 C) Max operating pressure 25 psi (862 kpa) Power requirements 20 V(ac)/24 V(ac) 60 Hz Primary pump Non-ferrous, Grundfos UPS5-58 Radiant pump Non-ferrous, Grundfos UPS5-58 Radiant 2 pump n/a Non-ferrous,Grundfos UPS5-58 DHW pump Non-ferrous, Grundfos UPS5-58 Auxiliary terminal n/a dry contact, max. load.5a Piping 4" 04 SS tubing Piping connections " FNPT Backplate 6 gauge galvanized steel Enclosure Powder coated steel New! ECOZNP ECO Boiler Panel 0 ea. New! ECO2ZN4P ECO Boiler Panel High Capacity 0 ea. 62

65 BOILER NOTE All Pumps with Check Valves LNG DHW Circ Weil Mclain LNG Primary Circ Radiant Circ Radiant Circ Room Thermostat DHW TANK Heating Supply & Return For Remote Manifolds. Room Thermostat Heating Supply & Return For Remote Manifolds. Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. Heat Source: Panel(s): Heat Load(s): Date: Weil-McLain ECO Boiler ECO2ZN4P Schematic #: SCH-ECO-M002 IFHWH, Radiant Heating Rough-in wiring see: SCH-MRIB-R Wiring detail see: SCH-ECO-E002 6

66 Heat Link V00 Boiler Panels V00 Boiler Panels V00 Series Primary Supply Primary Return Mechanical Room in a Box These panels are designed to work with Viessmann Vitodens 00-W boilers. The panel primary piping matches up to the Vitodens boiler system supply and return. The white color of the enclosure matches the Vitodens 00-W boiler. The panel has three or four Grundfos UPS5-58 pumps. There is a primary pump, a DHW water pump and one or two heating pumps. The primary pump is controlled by the boiler. The DHW pump is controlled by an aquastat (third party) wired to the terminal strip on the panel. Each heating pump is controlled by a thermostat (supplied separately) wired to the terminal strip on the panel. The water temperature is controlled by the boiler. Panel Components Primary Pump 2 DHW Pump Radiant Pump 4 Radiant 2 Pump (V02 only) 5 Electrical Connection Box 6 24V Terminal Strip 7 Isolation Valve 8 Drain Valve Panel Enclosure (not shown) V Expansion Tank Radiant 2 Return Radiant 2 Supply Radiant Return Radiant Supply DHW Return DHW Supply V0 V02 Listing cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 26-4"H 9-2"W 7-8"D Nominal panel output 80,000 btu/hr 00,000 btu/hr Nominal flow 6.0 US 5 F ΔT 0.0 US 5 F ΔT Max ambient temperature 20 F (49 C) Min operating temperature 40 F (4 C) Max operating temperature 200 F (9 C) Max operating pressure 25 psi (862 kpa) Power requirements 20 V(ac)/24 V(ac) 60 Hz Primary pump Non-ferrous, Grundfos UPS5-58 Radiant pump Non-ferrous, Grundfos UPS5-58 Radiant 2 pump n/a Non-ferrous, Grundfos UPS5-58 DHW pump Non-ferrous, Grundfos UPS5-58 Auxiliary terminal 2 dry contacts, max. load.5a Piping 4" 04 SS tubing Piping connections " FNPT Backplate 6 gauge galvanized steel Enclosure Powder coated steel New! V0 V00 Boiler Panel New! V02 V00 Boiler Panel High Capacity 64

67 DHW TANK BOILER LNG Primary Circ Radiant Circ Radiant Circ DHW Circ Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. NOTE All Pumps with Check Valves Heating Supply & Return For Remote Manifolds. Room Thermostat Heating Supply & Return For Remote Manifolds. Room Thermostat Heat Source: Panel(s): Heat Load(s): Viessmann Vitodens 00-W Boiler V02 Schematic #: SCH-V00-M00 IFHWH, Radiant Heating Rough-in wiring see: SCH-MRIB-R00 Date: Wiring detail see: SCH-V00-E002 65

68 Heat Link CAD Boiler Panels CAD Boiler Panels CAD Series CAD02 Mechanical Room in a Box These panels work with Lochinvar Cadet boilers. The dark grey color of the enclosure is similar to the Cadet boilers. The panel has three or four Grundfos UPS5-58 pumps. There is a primary pump, a DHW water pump and one or two heating pumps. The primary and DHW pumps are controlled by the boiler. On the CAD0 model, the heating pump is controlled by a thermostat (supplied separately) wired to the boiler. On the CAD02 model, each heating pump is controlled by a thermostat (supplied separately) wired to the terminal strip on the panel. The water temperature is controlled by the boiler. Panel Components Primary Pump DHW Pump Radiant Pump Radiant 2 Pump (CAD02 only) Electrical Connection Box 24V Terminal Strip (CAD02 only) Isolation Valve Panel Enclosure (not shown) Primary Supply Primary Return DHW Supply Radiant Supply Radiant Return Radiant 2 Supply Radiant 2 Return DHW Return CAD0 CAD02 Listing cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 26-4"H 9-2"W 7-8"D Nominal panel output 80,000 btu/hr 00,000 btu/hr Nominal flow 6.0 US 5 F ΔT 0.0 US 5 F ΔT Max ambient temperature 20 F (49 C) Min operating temperature 40 F (4 C) Max operating temperature 200 F (9 C) Max operating pressure 25 psi (862 kpa) Power requirements 20 V(ac)/24 V(ac) 60 Hz Primary pump Non-ferrous, Grundfos UPS5-58 Radiant pump Non-ferrous, Grundfos UPS5-58 Radiant 2 pump n/a Non-ferrous,Grundfos UPS5-58 DHW pump Non-ferrous, Grundfos UPS5-58 Auxiliary terminal n/a dry contact, max. load.5a Piping 4" 04 SS tubing Piping connections " FNPT Backplate 6 gauge galvanized steel Enclosure Powder coated steel Sept 204 Sept 204 CAD0 CAD Boiler Panel CAD02 CAD Boiler Panel High Capacity 66

69 BOILER CADET NOTE All Pumps with Check Valves LNG DHW Circ LNG Primary Circ Radiant Circ Radiant Circ Room Thermostat DHW TANK Room Thermostat Heating Supply & Return For Remote Manifolds. Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. Heat Source: Panel(s): Heat Load(s): Date: Lochinvar Cadet Boiler CAD02 Schematic #: SCH-CAD-M002 IFHWH, Radiant Heating Rough-in wiring see: SCH-MRIB-R Wiring detail see: SCH-CAD-E002 67

70 Heat Link Electric Boiler Panels ELBP Electric Boiler Panel Stk# ELBP0 & ELBP50 The Electric Boiler Panel includes an kv or 8kV electric boiler, automatic air vent, pressure relief valve, strainer, pump, connection for an expansion tank, 24Vac transformer, StatLink 6 Zone Base Module, and electrical box for 240V connection. ELBP The Electric Boiler Panel s primary application is for heating small areas where quick plug and play installation is needed or alternative fuel sources aren t available. 9 8 Panel Components 7 Mechanical Room in a Box Electric Boiler Primary Pump 240Vac Electrical Connection Box 0Vac Terminal Strip 24Vac Transformer StatLink 6 Zone Base Module Strainer Automatic Air Vent Pressure Relief Valve Isolation Valve Panel Enclosure (not shown) Pressure Relief Primary Supply Expansion Tank Primary Return ELBP0 ELBP50 Listing cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 7-2"H 29-4"W 4-4"D Nominal panel output 0,000 btu/hr 50,000 btu/hr Nominal flow.0 US 5 F ΔT 5.0 US 5 F ΔT Max ambient temperature 20 F (49 C) Min operating temperature 40 F (4 C) Max operating temperature 200 F (9 C) Max operating pressure 25 psi (862 kpa) Power requirements 20 V(ac) / 240 V(ac) 60 Hz Primary pump Non-ferrous, Grundfos UPS5-58 Auxiliary terminal dry contact, max. load 8A Piping 4" 04 SS tubing Piping connections " FNPT Backplate 6 gauge galvanized steel Enclosure Powder coated steel ELBP0 Electric Boiler Panel 0,000BTU New! ELBP50 Electric Boiler Panel 50,000BTU 68

71 Vac ELBP0/50 Panel Extend pressure relief pipe to within 6" of floor. Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. 240Vac Thermostat Recommended Sidestream Filter Radiant Heating Manifold Heat Source: Panel(s): Heat Load(s): Electric Boiler ELBP0, ELBP50 Radiant Heating Single Zone Date: Schematic #: Rough-in wiring see: Wiring detail see: SCH-ELBP-M00 SCH-MRIB-R00 SCH-ELBP-E00 69

72 Heat Link Electric Boiler Panels with Manifold ELBP Electric Boiler Panel with Manifold Stk# ELBP0TS, ELBP0TS5, & ELBP50TS7 The Electric Boiler Panel includes an kv or 8kV electric boiler, automatic air vent, pressure relief valve, strainer, pump, connection for an expansion tank, TwistSeal Multiport Mini Manifold, 24Vac transformer, StatLink 6 Zone Base Module, and electrical box for 240V connection. ELBP50TS The Electric Boiler Panel s primary application is for heating small areas where quick plug and play installation is needed or alternative fuel sources aren t available. 9 8 Panel Components 7 Mechanical Room in a Box Electric Boiler Primary Pump 240Vac Electrical Connection Box 0Vac Terminal Strip 24Vac Transformer StatLink 6 Zone Base Module Strainer Automatic Air Vent Pressure Relief Valve Isolation Valve TwistSeal Mini Multiport Manifold Thermometer Hosebib Panel Enclosure (not shown) Pressure Relief Expansion Tank ELBP0TS, ELBP0TS5 ELBP50TS7 Listing cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 7-2"H 29-4"W 4-4"D Nominal panel output 0,000 btu/hr 50,000 btu/hr Nominal flow.0 US 5 F ΔT 5.0 US 5 F ΔT Max ambient temperature 20 F (49 C) Min operating temperature 40 F (4 C) Max operating temperature 200 F (9 C) Max operating pressure 25 psi (862 kpa) Power requirements 20 V(ac) / 240 V(ac) 60 Hz Primary pump Non-ferrous, Grundfos UPS5-58 Auxiliary terminal dry contact, max. load 8A Piping 4" 04 SS tubing Piping connections " FNPT Backplate 6 Gauge galvanized steel Enclosure Powder coated steel New! New! ELBP0TS ELBP0TS5 ELBP50TS7 Electric Boiler Panel 0,000BTU with Loop Twist Seal Mini Multiport Electric Boiler Panel 0,000BTU with 5 Loop Twist Seal Mini Multiport Electric Boiler Panel 50,000BTU with 7 Loop Twist Seal Mini Multiport 70

73 Vac ELBP50TS7 Panel Extend pressure relief pipe to within 6" of floor. Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. Thermostat 240Vac Heat Source: Panel(s): Heat Load(s): Electric Boiler ELBP0TS, ELBP0TS5, ELBP50TS7 Radiant Heating Single Zone Date: Schematic #: Rough-in wiring see: Wiring detail see: SCH-ELBP-M002 SCH-MRIB-R00 SCH-ELBP-E00 7

74 Heat Link TMP -Way Mixing Panels TMP 40/70 MBH -Way Mixing Panels Stk# TMP040 & TMP070 The TMP -Way Mixing Panel s primary application is as a single zone mixing device where there are no flow requirements in the primary loop. Intended to be used with DHW tanks as a heat source, the pump is activated once every 24 hours, for 5 minutes, to ensure that potable water in the piping is not stagnant. At this time, a DHW priority option for these panels is not available. TMP040 Primary Supply Primary Return These panels can also be used as subpanels to provide additional mixed temperature loops. When the panel receives a call for heat, the pump is activated, and the thermostatic control head in the -way mixing valve will automatically regulate the water temperature in the secondary circuit. When not used with a DHW tank as a heat source, secondary zoning downstream of the panel is possible. 2 Mechanical Room in a Box Panel Components 2 4 Pump -Way Thermostatic Mixing Valve Power Box with 6' Power Cord 24hr Timer for Potable Applications Auxiliary Dry Contacts for Heat Source Bypass Function Thermometer Panel Enclosure (not shown) 4 Secondary Supply Secondary Return TMP040 TMP070 Listing cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 4-4"H 2-2"W 6-2"D Weight 5 lbs. 7 lbs. Nominal panel output 40,000 Btu/hr 70,000 Btu/hr Nominal flow 4.0 US 20 F ΔT 7.0 US 20 F ΔT Nominal pressure drop outside of panel 4 ft Max ambient temperature 20 F Max water temperature 200 F Min required flow for correct temp control US gpm Power supply: pre-wired on system controller 0 V(ac); max. current A Pump Non-ferrous, Grundfos UPS5-58 Auxiliary terminal dry contact, max. load.5a Temperature control method 4" -Way thermostatic " -Way thermostatic Temperature control range 0-40 F 0-40 F Mix Valve Cv.8.7 Piping 4" 04 SS tubing Piping connections 4" FNPT " FNPT Backplate 6 gauge galvanized steel Enclosure Powder coated steel TMP040 TMP 40MBH -way Mixing Panel TMP070 TMP 70MBH -way Mixing Panel 72

75 DHWtoandfrom House Heat Source TMP040/070 Panel Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. Heat Source: Panel(s): Heat Load(s): Generic TMP Series Generic Single Zone Date: Thermostat Heating Load Schematic #: Rough-in wiring see: Wiring detail see: SCH-TMP-M00 SCH-MRIB-R00 SCH-TMP-E00 7

76 Heat Link TMP -Way Mixing Panel with Zoning TMP 70 MBH -Way Mixing Panel with Zoning Stk# TMP070Z The TMP -Way Mixing Panel s primary application is as a multizone mixing device where there are no flow requirements in the primary loop. Intended to be used with DHW tanks as a heat source, the pump is activated, and actuators (sold separately) are opened once every 24 hours, for 5 minutes, to ensure that potable water in the piping is not stagnant. The power box has thermostat inputs and actuator outputs for up to four zones (two actuators per zone). At this time, a DHW priority option for this panel is not available. 4 Primary Supply Primary Return When the panel receives a call for heat, the pump is activated, and the thermostatic control head in the -way mixing valve will automatically regulate the water temperature in the secondary circuit. When used with a DHW tank as a heat source, secondary zoning downstream of the panel is possible (subject to local codes). 2 Mechanical Room in a Box Panel Components Pump 2 -Way Thermostatic Mixing Valve Power Box with 6' Power Cord 24hr Timer for Potable Applications Auxiliary Dry Contacts for Heat Source Thermostat Inputs and Actuator Outputs for 4 Zones Bypass Function 4 24Vac Plug-in Transformer Thermometer Panel Enclosure (not shown) 5 5 Secondary Supply Secondary Return TMP070Z Listing cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 4-4"H 2-2"W 6-2"D Weight 7 lbs. Nominal panel output 70,000 Btu/hr Nominal flow 7.0 US 20 F ΔT Nominal pressure drop outside of panel 4 ft Max ambient temperature 20 F Max water temperature 200 F Min required flow for correct temp control US gpm Power supply: pre-wired on system controller 0 V(ac); max. current 2A Pump Non-ferrous, Grundfos UPS5-58 Auxiliary terminal dry contact, max. load.5a Temperature control method " -Way thermostatic Temperature control range 0-40 F Mix Valve Cv.7 Piping 4" 04 SS tubing Piping connections " FNPT Backplate 6 gauge galvanized steel Enclosure Powder coated steel Special Order* TMP070Z TMP 70MBH -way Mixing Panel with Zoning 74 * Lead time may vary. Call to confirm time line.

77 DHW to and from House Heat Source TMP070Z Panel Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. Heat Source: Panel(s): Heat Load(s): Generic TMP070Z Generic Up to 4 Zones Date: Heating Load Up to 4 Zones Schematic #: Rough-in wiring see: Wiring detail see: SCH-TMPZ-M00 SCH-MRIB-R006 SCH-TMPZ-E00 75

78 Heat Link TMP Dual Pump -Way Mixing Panel TMP 85 MBH Dual Pump Mixing Panel Stk# TMP085DP The TMP -Way Mixing Panel s primary application is as a single zone mixing device where there are no flow requirements in the primary loop. Intended to be used with DHW tanks as a heat source, the pump is activated once every 24 hours, for 5 minutes, to ensure that potable water in the piping is not stagnant. At this time, a DHW priority option for this panel is not available. These panels can also be used as subpanels to provide additional mixed temperature loops. Primary Return Primary Supply 4 Mechanical Room in a Box When the panel receives a call for heat, the pump is activated, and the thermostatic control head in the -way mixing valve will automatically regulate the water temperature in the secondary circuit. When not used with a DHW tank as a heat source, secondary zoning downstream of the panel is possible. The TMP085DP not only allows for higher output, but it is also a 2-zone panel. So even with a DHW heat source, you can now have two radiant floor zones. Panel Components Zone Pump with Check Valve 2 Zone 2 Pump with Check Valve -Way Thermostatic Mixing Valve 4 Power Box with 6' Power Cord 24hr Timer for Potable Applications Bypass Function Auxiliary Dry Contacts for Heat Source Thermometer Panel Enclosure (not shown) 5 Zone 2 Return 5 Zone Return 2 Zone Supply Zone 2 Supply TMP085DP Listing cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 8-4"H 6-4"W 7-4"D Weight 0 lbs. Nominal panel output 85,000 Btu/hr Nominal flow US 20 F ΔT Nominal pressure drop outside of panel 4 ft Max ambient temperature 20 F Max water temperature 200 F Min required flow for correct temp control US gpm Power supply: pre-wired on system controller 0 V(ac); max. current 2A Zone pump Non-ferrous, Grundfos UPS5-58 Zone 2 pump Non-ferrous, Grundfos UPS5-58 Auxiliary terminal dry contact, max. load.5a Temperature control method " -Way thermostatic Temperature control range 0-40 F Mix Valve Cv.0 Piping 4" 04 SS tubing Piping connections " FNPT primary, 4" FNPT secondary Backplate 6 gauge galvanized steel Enclosure Powder coated steel TMP085DP TMP 85MBH Dual Pump -way Mixing panel 76

79 DHW to and from House Heat Source Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. TMP085DP Panel Check Valve in Both Pumps Heat Source: Panel(s): Heat Load(s): Generic TMP085DP Generic Dual Zones Date: Heating Zone 2 Heating Zone Zone 2 Thermostat Zone Thermostat Schematic #: Rough-in wiring see: Wiring detail see: SCH-TMPDP-M00 SCH-MRIB-R00 SCH-TMPD-E00 77

80 Heat Link TMP 2-Temperature -Way Mixing Panel TMP 200 MBH 2-Temperature Mixing Panel Stk# TMP200DT The TMP -Way Mixing Panel s primary application is as a single zone mixing device where there are no flow requirements in the primary loop. Intended to be used with DHW tanks as a heat source, the pump is activated once every 24 hours, for 5 minutes, to ensure that potable water in the piping is not stagnant. At this time, a DHW priority option for this panel is not available. These panels can also be used as subpanels to provide additional mixed temperature loops. Primary Return Primary Supply 4 Mechanical Room in a Box When the panel receives a call for heat, the pump is activated, and the thermostatic control head in the -way mixing valve will automatically regulate the water temperature in the secondary circuit. When not used with a DHW tank as a heat source, secondary zoning downstream of the panel is possible. The TMP200DT is a dual temperature panel. The low temperature output is the same as the TMP070, but it also has a high temperature pump, for secondary high temperature applications such as a fan coil or baseboard. Panel Components Mixed Temp Pump with Check Valve High Temp Pump with Check Valve -Way Thermostatic Mixing Valve Power Box with 6' Power Cord 24hr Timer for Potable Applications Bypass Function Auxiliary Dry Contacts for Heat Source Thermometer Panel Enclosure (not shown) Mixed Temp Return High Temp Return Mixed Temp Supply High Temp Supply TMP200DT Mixed Temp High Temp Listing cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 8-4"H 6-4"W 7-4"D Weight 0.5 lbs. Nominal panel output 70,000 Btu/hr 0,000 Btu/hr Nominal flow 7.0 US 20 F ΔT 0.0 US 26 F ΔT Nominal pressure drop outside of panel 4 ft 8 ft Max ambient temperature 20 F Max water temperature 200 F Min required flow for correct temp control US gpm n/a Power supply: pre-wired on system controller 0 V(ac); max. current 2A Pump Non-ferrous, Grundfos UPS5-58 Non-ferrous, Grundfos UPS5-58 Auxiliary terminal dry contact, max. load.5a Temperature control method " -Way thermostatic None Temperature control range 0-40 F n/a Mix Valve Cv.0 n/a Piping 4" 04 SS tubing Piping connections " FNPT primary, 4" FNPT secondary Backplate 6 gauge galvanized steel Enclosure Powder coated steel TMP200DT TMP 200MBH 2-Temperature -way Mixing Panel 78

81 DHW to and from House Heat Source Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. Check Valve in Both Pumps TMP200DT Panel Heat Source: Panel(s): Heat Load(s): Generic TMP200DT Generic Dual Zones Date: Heating Zone 2 Heating Zone Zone 2 Thermostat Zone Thermostat Schematic #: Rough-in wiring see: Wiring detail see: SCH-TMPDT-M00 SCH-MRIB-R00 SCH-TMPD-E00 79

82 Heat Link TWH Tankless Water Heater Panel TWH 70 MBH Tankless Water Heater Mixing Panel Stk# TWH070 The TWH Tankless Water Heater Mixing Panel s primary application is as a single zone mixing device for tankless DHW heaters. Both the primary and secondary pumps are activated once every 24 hours, for 5 minutes, to ensure that potable water in the piping is not stagnant. When the panel receives a call for heat, both pumps are activated, and the thermostatic control head in the -way mixing valve will automatically regulate the water temperature in the secondary circuit. DHW priority is not available on this model. 4 Panel Components 5 Mechanical Room in a Box Primary Pump with Check Valve Secondary Pump Power Box with 6' Power Cord 24hr Timer for Potable Applications Bypass Function Auxiliary Dry Contacts for Heat Source -Way Thermostatic Mixing Valve Thermometer Panel Enclosure (not shown) Primary Supply Primary Return (lower pipe) Secondary Return (upper pipe) 2 Secondary Supply TWH070 Listing cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 8-4"H 6-4"W 7-4"D Weight 28.5 lbs. Nominal panel output 70,000 btu/hr Primary nominal flow 4.0 US 5 F ΔT Primary nominal pressure drop outside of panel 4 ft Secondary nominal flow 7 US 20 F ΔT Secondary nominal pressure drop outside of panel 4 ft Max ambient temperature 20 F Max water temperature 200 F Min required flow for correct temp control US gpm Power supply: pre-wired on system controller 0 V(ac); max. current 2A Primary pump Non-ferrous, Grundfos UPS5-58 Secondary pump Non-ferrous, Grundfos UPS5-58 Auxiliary terminal dry contact, max. load.5a Temperature control method " -Way thermostatic Temperature control range 00 F - 45 F Mix Valve Cv.0 Piping 4" 04 SS tubing Piping connections " FNPT Backplate 6 gauge galvanized steel Enclosure Powder coated steel TWH070 TWH 70MBH Tankless Water Heater Mixing Panel 80

83 Heat Source Check Valve in Primary Pump Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. TWH070 Panel Heat Source: Panel(s): Heat Load(s): Generic TWH070 Generic Single Zone Date: DHW Supply to House Thermostat Heating Load Schematic #: Rough-in wiring see: Wiring detail see: SCH-MRIB-R00 SCH-TWH-E00 8

84 Heat Link TWH Tankless Water Heater Panels with Optional DHW Priority TWH 70 MBH Tankless Water Heater Mixing Panels with Optional DHW Priority Stk# TWH070P & TWH070XP TWH070XP The TWH Tankless Water Heater Mixing Panel s primary application is as a single zone mixing device for tankless DHW heaters. Both the primary and secondary pumps are activated once every 24 hours, for 5 minutes, to ensure that potable water in the piping is not stagnant. When the panel receives a call for heat, both pumps are activated, and the thermostatic control head in the -way mixing valve will automatically regulate the water temperature in the secondary circuit. The TWH070XP is designed for applications where there is an extremely high flow resistance in the heat source. Both the TWH070P and the TWH070XP are compatible with the optional flow switch (FLWSWTCH) that turns off the primary pump when there is flow in the regular DHW line. 4 5 Mechanical Room in a Box Panel Components Primary Pump with Check Valve Secondary Pump Power Box with 6' Power Cord 24hr Timer for Potable Applications Bypass Function Auxiliary Dry Contacts for Heat Source -Way Thermostatic Mixing Valve Thermometer Panel Enclosure (not shown) FLWSWTCH Primary Supply Primary Return (lower pipe) Secondary Return (upper pipe) 2 Secondary Supply TWH070P TWH070XP Listing cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 8-4"H 6-4"W 7-4"D Weight 2.5 lbs. 9 lbs. Nominal panel output 70,000 btu/hr 70,000 btu/hr Primary nominal flow 4.0 US 5 F ΔT 4.0 US 5 F ΔT Primary nominal pressure drop outside of panel 4 ft 24 ft Secondary nominal flow 7 US 20 F ΔT 7 US 20 F ΔT Secondary nominal pressure drop outside of panel 4 ft 4 ft Max ambient temperature 20 F Max water temperature 200 F Min required flow for correct temp control US gpm Power supply: pre-wired on system controller 0 V(ac); max. current 2A 0 V(ac); max. current A Primary pump Non-ferrous, Grundfos UPS5-58 Non-ferrous, Grundfos UPS26-99BFC Secondary pump Non-ferrous, Grundfos UPS5-58 Non-ferrous, Grundfos UPS5-58 Auxiliary terminal dry contact, max. load.5a DHW priority ~0.5 US gpm DHW flow Temperature control method " -Way thermostatic Temperature control range 00 F - 45 F Mix Valve Cv.0 Piping 4" 04 SS tubing Piping connections " FNPT DHW priority switch connection 2" FNPT (FLWSWTCH optional) Backplate 6 gauge galvanized steel Enclosure Powder coated steel Special Order* TWH070P TWH 70MBH Tankless Water Heater Mixing Panel (DHW Priority Opt) TWH070XP TWH 70MBH HH Tankless Water Heater Mixing Panel (DHW Priority Opt) FLWSWTCH Flow Switch for Domestic Hot Water Priority 82 * Lead time may vary. Call to confirm time line.

85 Heat Source Check Valve in Primary Pump Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. TWH070P/ TWH070XP Panel FS Optional DHW Priority Switch Heat Source: Panel(s): Heat Load(s): Generic TWH Series Generic Single Zone Date: DHW Supply to House Thermostat Heating Load Schematic #: Rough-in wiring see: Wiring detail see: SCH-TWH-M00 SCH-MRIB-R00 SCH-TWH-E00 8

86 Heat Link TWH Tankless Water Heater Panels with Zoning TWH 70 MBH Tankless Water Heater Mixing Panels with Zoning Stk# TWH070Z & TWH070XPZ 4 The TWH Tankless Water Heater Mixing Panel s primary application is as a multizone mixing device for tankless DHW heaters. Both the primary and secondary pumps are activated once every 24 hours, for 5 minutes, to ensure that potable water in the piping is not stagnant. The power box has thermostat inputs and actuator outputs for up to four zones (two actuators per zone). At this time, a DHW priority option for these panels is not available. When the panel receives a call for heat, both pumps are activated, and the thermostatic control head in the -way mixing valve will automatically regulate the water temperature in the secondary circuit. The TWH070XPZ is designed for applications where there is an extremely high flow resistance in the heat source. TWH070Z 5 6 Mechanical Room in a Box Panel Components Primary Pump with Check Valve Secondary Pump Power Box with 6' Power Cord 24hr Timer for Potable Applications Auxiliary Dry Contacts for Heat Source Thermostat Inputs and Actuator Outputs for 4 Zones Bypass Function 24Vac Plug-in Transformer -Way Thermostatic Mixing Valve Thermometer Panel Enclosure (not shown) Primary Supply Primary Return (lower pipe) Secondary Return (upper pipe) 2 Secondary Supply TWH070Z TWH070XPZ Listing cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 8.25"H x 6.25"W x 8"D Nominal panel output 70,000 btu/hr 70,000 btu/hr Primary nominal flow 4.0 US 5 F ΔT 4.0 US 5 F ΔT Primary nominal pressure drop outside of panel 4 ft 24 ft Secondary nominal flow 7 US 20 F ΔT 7 US 20 F ΔT Secondary nominal pressure drop outside of panel 4 ft 4 ft Max ambient temperature 20 F Max water temperature 200 F Min required flow for correct temp control US gpm Power supply: pre-wired on system controller 0 V(ac); max. current 2A Primary circulator Non-ferrous, Grundfos UPS5-58 Non-ferrous, Grundfos UPS26-99BFC Secondary circulator Non-ferrous, Grundfos UPS5-58 Non-ferrous, Grundfos UPS5-58 Auxiliary terminal dry contact, max. load.5a Temperature control method " -Way thermostatic Temperature control range 00 F - 45 F Valve Cv.0 Piping 4" 04 SS tubing Piping connections " FNPT Backplate 6 gauge galvanized steel Enclosure Powder coated steel Special Order* Special Order* TWH070Z TWH 70MBH Tankless Water Heater Mixing Panel with Zoning TWH070XPZ TWH 70MBH High Head Tankless Water Heater Mixing Panel with Zoning 84 * Lead time may vary. Call to confirm time line.

87 Heat Source Check Valve in Primary Pump Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. TWH070Z/ TWH070XPZ Panel Heat Source: Panel(s): Heat Load(s): Generic TWHZ Series Generic Up to 4 Zones Date: DHW Supply to House Heating Load Up to 4 Zones Schematic #: Rough-in wiring see: Wiring detail see: SCH-TWHZ-M00 SCH-MRIB-R006 SCH-TWHZ-E00 85

88 Heat Link HEP Isolation Heat Exchanger Panels HEP Isolation Heat Exchanger Panels HEP Series Secondary Return Secondary Supply The main application of the HEP Isolation Heat Exchanger Panel is to provide single wall isolation between a DHW tank and a heating system. While other applications are possible, it is important to note that this panel is not a temperature control device. The secondary water temperature is wholly dependent on the temperature of the primary supply water. When the panel receives a call for heat, it activates both primary and secondary pumps. The primary pump is also activated once every 24 hours, for 5 minutes, to ensure that potable water in the piping or heat exchanger is not stagnant. HEP025P The panel is pre-wired to work with a DHW priority switch which is mounted outside the panel. 5 Mechanical Room in a Box Panel Components Primary Pump 2 Secondary Pump Brazed Plate Heat Exchanger 4 Power Box with 6' Power Cord 24hr Timer for Potable Applications Bypass Function Auxiliary Dry Contacts for Heat Source 5 Pressure Relief Valve 6 Pressure Gauge 7 Automatic Air Vent 8 Drain and Fill Valve Panel Enclosure (not shown) 8 Primary Supply Primary Return HEP025P HEP080P Listing cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 8-4"H 8-4"W 7-4"D Weight 0 lbs 2.5 lbs Nominal panel output see conditions to the right 25,000 Btu/hr 80,000 Btu/hr Max ambient temperature 20 F Max water temperature 200 F Settable fluid temp range dependant on heat source temperature Power supply: pre-wired on system controller 0 V(ac); max. current 2A Primary pump Non-ferrous, Grundfos UPS5-58 Secondary pump Non-ferrous, Grundfos UPS5-58 Heat exchanger Single-wall brazed plate; 8-2 Single-wall brazed plate; 8-0 Auxiliary terminal Yes DHW priority ~0.5 US gpm DHW flow Temperature control method None Piping 4" 04 SS tubing Piping connections " FNPT, 4" FNPT DHW priority switch connection 2" FNPT (FLWSTCH optional) Backplate 6 gauge galvanized steel Enclosure Powder coated steel FLWSWTCH Panel Output Conditions Primary Side Secondary Side HEP025 Fluid type Water Water Entering fluid temp ( F) 40 F 00 F Exiting fluid temp ( F) 20 F 20 F Flow rate (US gpm) US gpm US gpm Pressure drop (ft head) ft 2 ft Allowable pressure drop outside of ft 4 ft Panel (ft head) HEP080 Fluid type Water Water Entering fluid temp ( F) 40 F 00 F Exiting fluid temp ( F) 20 F 20 F Flow rate (US gpm) 8. US gpm 8. US gpm Pressure drop (ft head).9 ft.7 ft Allowable pressure drop outside of Panel (ft head) 6 ft 6 ft HEP025P HEP 25MBH Isolation Heat Exchanger Panel HEP080P HEP 80MBH Isolation Heat Exchanger Panel FLWSWTCH Flow Switch for Domestic Hot Water Priority 86

89 Heat Source HEP Series Panel Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. FS DHW Supply to House Optional DHW Priority Switch Heat Source: Panel(s): Heat Load(s): Generic HEP Series Generic Single Zone Date: Thermostat Heating Load Schematic #: Rough-in wiring see: Wiring detail see: SCH-HEP-M00 SCH-MRIB-R00 SCH-HEP-E00 87

90 Heat Link HEP Isolation Heat Exchanger Panels HEP Isolation Heat Exchanger Panels HEP Series Secondary Return Secondary Supply The main application of the HEP Isolation Heat Exchanger Panel is to provide single wall isolation between a DHW tank and a heating system. While other applications are possible, it is important to note that this panel is not a temperature control device. The secondary water temperature is wholly dependent on the temperature of the primary supply water. The HEP095P is designed for applications where there is an extremely high flow resistance in the heat source. When the panel receives a call for heat, it activates both primary and secondary pumps. The primary pump is also activated once every 24 hours, for 5 minutes, to ensure that potable water in the piping or heat exchanger is not stagnant. The panel is pre-wired to work with a DHW priority switch which is mounted outside the panel Mechanical Room in a Box Panel Components Primary Pump 2 Secondary Pump Brazed Plate Heat Exchanger 4 Power Box with 6' Power Cord 24hr Timer for Potable Applications Bypass Function Auxiliary Dry Contacts for Heat Source 5 Pressure Relief Valve 6 Pressure Gauge 7 Automatic Air Vent 8 Drain and Fill Valve Panel Enclosure (not shown) 8 HEP095P Listing cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 24"H 8-4"W 7-4"D Weight 46.5 lbs Nominal panel output 95,000 Btu/hr *see conditions to the right Max ambient temperature 20 F Max water temperature 200 F Settable fluid temp range dependant on heat source temperature Power supply: pre-wired on system controller 0 V(ac); max. current A Primary pump Non-ferrous, Grundfos UPS26-99BFC Secondary pump Non-ferrous, Grundfos UPS5-58 Heat exchanger Single-wall brazed plate; 8-0 Auxiliary terminal dry contact, max. load.5a DHW priority ~0.5 US gpm DHW flow Temperature control method None Piping 4" 04 SS tubing Piping connections " FNPT, 4" FNPT DHW priority switch connection 2" FNPT (FLWSWTCH optional) Backplate 6 gauge galvanized steel Enclosure Powder coated steel FLWSWTCH Primary Supply Primary Return Panel Output Conditions Primary Side Secondary Side Fluid type Water Water Entering fluid temp ( F) 40 F 00 F Exiting fluid temp ( F) 25 F 27 F Flow rate (US gpm) US gpm 7 US gpm Pressure drop (ft head) 0 ft ft Allowable pressure drop outside of Panel (ft head) 0 ft 9 ft Special Order* HEP095P HEP 95MBH Isolation Heat Exchanger Panel FLWSWTCH Flow Switch for Domestic Hot Water Priority 88 * Lead time may vary. Call to confirm time line.

91 Heat Source HEP Series Panel Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. FS DHW Supply to House Optional DHW Priority Switch Heat Source: Panel(s): Heat Load(s): Generic HEP Series Generic Single Zone Date: Thermostat Heating Load Schematic #: Rough-in wiring see: Wiring detail see: SCH-HEP-M00 SCH-MRIB-R00 SCH-HEP-E00 89

92 Heat Link WHP Water Heater Panel WHP 0 MBH Water Heater Pump Panel with optional DHW Priority Stk# WHP0P The WHP Water Heater Pump Panel s primary application is as a flow activated DHW priority switched pump. Intended to be used with DHW tanks as a heat source, the pump is activated once every 24 hours, for 5 minutes, to ensure that potable water in the piping is not stagnant. The WHP0P is compatible with the optional flow switch (FLWSWTCH) that turns off the primary pump when there is flow in the regular DHW line. Mechanical Room in a Box Panel Components Primary Pump 2 Power Box with 6' Power Cord 24hr Timer for Potable Applications Bypass Function Auxiliary Dry Contacts for Heat Source Thermometer Panel Enclosure (not shown) High Temp Supply High Temp Return WHP0P Listing cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 2"H - 4"W 7"D Weight 2 lbs. Nominal panel output 0,000 Btu/h Nominal flow 0 US 26 F ΔT Nominal pressure drop outside of panel 8 ft Max ambient temperature 20 F Max water temperature 200 F Power supply: pre-wired on system controller 0 V(ac): max. current A Pump Non-ferrous, Grundfos UPS5-58 Auxiliary terminal dry contact, max. load.5a DHW priority ~0.5 US gpm DHW flow Temperature control method None Piping 4" 04 SS tubing Piping connections 4" FNPT DHW priority switch connection 2" FNPT (FLWSTCH optional) Backplate 6 gauge galvanized steel Enclosure Powder coated steel 2 FLWSWTCH Primary Supply Primary Return Special Order* WHP0P WHP 0MBH Water Heater Pump Panel (DHW Priority Optional) FLWSWTCH Flow Switch for Domestic Hot Water Priority 90 * Lead time may vary. Call to confirm time line.

93 Thermostat Heating Load Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. Optional DHW Priority Switch WHP0P Panel T Heat Source: Panel(s): Heat Load(s): Generic WHP0P Generic Single Zone Date: DHW to and from House FS Heat Source Schematic #: Rough-in wiring see: Wiring detail see: SCH-WHP-M00 SCH-MRIB-R00 SCH-WHP-E00 9

94 Heat Link CDP 200 MBH 2-Temperature Combi DHW Panel CDP 200 MBH 2-Temperature System Panel Stk# CDP200R2 6 The CDP200R2 Combi Panel operates as a high/low temperature distribution center, with a boiler (or other non-dhw appliance) as a heat source. The CDP200R2 has one high temperature branch that can be used for an indirect-fired DHW tank (with priority), or a high temperature heating application such as fan coils or baseboards. The thermostatic control head in the -way mixing valve will automatically regulate the water temperature in the secondary circuit. 4 Mechanical Room in a Box Panel Components Primary Pump 2 Mixed Temp Pump DHW / High Temp Pump 4 Power Box with 6' Power Cord Purge Timer on All Circuits Bypass Function Auxiliary Dry Contacts for Heat Source 5 -Way Thermostatic Mixing Valve 6 24Vac Plug-in Transformer Thermometer Panel Enclosure (not shown) 7 7 CDP200R2 Listing cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 8-4"H 6-4"W 7-4"D Weight 4.5 lbs. Nominal panel output* - see conditions below 200,000 Btu/hr* Max ambient temperature 20 F Max water temperature 200 F Settable fluid temp range F Min required flow for correct temp control US gpm Power supply: pre-wired on system controller 0 V(ac); max. current A Primary pump Non-ferrous, Grundfos UPS5-58 Low temp pump Non-ferrous, Grundfos UPS5-58 High temp/dhw pump Non-ferrous, Grundfos UPS5-58 Auxiliary terminal 2 dry contacts, max. load.5a Temperature control method " -Way thermostatic Mix Valve Cv.0 Piping 4" 04 SS tubing Piping connections " FNPT Backplate 6 gauge galvanized steel Enclosure Powder coated steel DHW / High Temp Return Primary Supply DHW / High Temp Supply 5 Secondary Return (upper pipe) Primary Return (lower pipe) 2 Secondary Supply Panel Output Conditions Primary Mixed Temp DHW / High Temp Nominal output (Btu/h) 200,000 60,000 40,000 Fluid type Water Water Water ΔT ( F) 40 F 20 F 26 F Flow rate (US gpm) 0 US gpm 6 US gpm 0 US gpm Pressure drop (ft head) 8 ft 4 ft 8 ft CDP200R2 CDP 200MBH 2-Temp System Panel with Pumps Rev2 92

95 Thermostat Heating Load (DHW / High Temp) Heat Source Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. Check Valve in Primary, Radiant, And DHW/ Hi Temp Pumps CDP200R2 Panel Thermostat Heating Load (Low Temp) Heat Source: Panel(s): Heat Load(s): Generic CDP200R2 Generic Low Temp, Generic High Temp Date: Schematic #: Rough-in wiring see: Wiring detail see: SCH-CDP-M00 SCH-MRIB-R00 SCH-CDP-E00 9

96 Heat Link CDP MBH 2 or Temperature Combi DHW Panels CDP MBH 2-Temperature Combi DHW System Panels Stk# CDP220R2 & CDP250R2 Mechanical Room in a Box The CDP220R2 and 250R2 Combi Panels operate as high/low temperature distribution centers, with a boiler (or other non-dhw appliance) as a heat source. The CDP panels each have two high temperature branches with pumps, one for the indirect-fired DHW tank (with priority) and one for the high temperature heating application. The thermostatic control head in the -way mixing valve will automatically regulate the water temperature in the secondary circuit. The panels have three outputs to the boiler. Note: these panels are not compatible with IBC boilers. Panel Components Primary Pump 2 Mixed Temp Pump DHW Pump with Priority High Temp Pump (CDP220R2 and CDP250R2 only) 5 Power Box Purge Timers on All Circuits Bypass Function 6 Relay Box with 6' Power Cord 7 Terminal Strip 8 24Vac Plug-in Transformer 9 -Way Thermostatic Mixing Valve 0 Thermometer Isolation Valve 2 Drain and Fill Valve Panel Enclosure (not shown) Primary Supply Primary Return 8 DHW Return High Temp Return DHW Supply 2 High Temp Supply Mixed Temp Return 0 Mixed Temp Supply 2 7 CDP250R2 9 2 CDP220R2 CDP250PR2 CDP250R2 Listing cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 0-4"H 8-8"W 7-7 8"D Weight 08 lbs 8 lbs 2 lbs Nominal panel output - see conditions below 220,000 Btu/h* 250,000 Btu/h* Max ambient temperature 20 F Max water temperature 200 F Settable fluid temp range 0-40 F Min required flow for correct temp control US gpm Power supply: pre-wired on system controller 0 V(ac); max. current 5A 0 V(ac); max. current 6A Primary circulator Non-ferrous, Grundfos UPS5-58 Ferrous, Grundfos UPS26-99FC Low temp circulator Non-ferrous, Grundfos UPS5-58 Ferrous, Grundfos UPS26-99FC DHW circulator Non-ferrous, Grundfos UPS5-58 High temp circulator Non-ferrous, Grundfos UPS5-58 n/a Non-ferrous, Grundfos UPS5-58 Auxiliary terminal dry contacts, max. load.5a Temperature control method " -way thermostatic mixing valve Mix Valve Cv.7 Piping " 04 Stainless steel tubing Piping connections " FNPT Backplate Galvanized steel Enclosure Powder coated steel CDP220R2 CDP250PR2 & CDP250R2 Panel Output Conditions Primary Mixed Temp High Temp Primary Mixed Temp High Temp Nominal output (Btu/h) 220,000 70,000 50, ,000 00,000 50,000 Fluid type Water Water Water Water Water Water ΔT ( F) 40 F 20 F 0 F 0 F 20 F 0 F Flow rate (US gpm) US gpm 7 US gpm 0 US gpm 7 US gpm 0 US gpm 0 US gpm Pressure drop (ft head) 7 ft 4 ft 8 ft 7 ft 7 ft 8 ft Special Order* Special Order* Special Order* CDP220R2 CDP250PR2 CDP250R2 CDP 220MBH 2-Temp Combi DHW System Panel with 4 Pumps Rev2 CDP 250MBH 2-Temp Combi DHW System Panel with Pumps Rev2 CDP 250MBH 2-Temp Combi DHW System Panel with 4 Pumps Rev2 94 * Lead time may vary. Call to confirm time line.

97 Heat Source Heating Load (DHW) Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. Heating Load (High Temp) Heat Source: Panel(s): Heat Load(s): Generic CDP220R2/CDP250R2 Generic Date: CDP220R2/ CDP250R2 Panel Heating Load (Mixed Temp) Schematic #: Rough-in wiring see: Wiring detail see: SCH-CDP-M007 95

98 Heat Link CDP 0 MBH 2 or Temperature Combi DHW Panels CDP 0 MBH 2-Temperature System Panels with Outdoor Reset Stk# CDP0RP & CDP0RP4 Mechanical Room in a Box The CDP0R Combi Panels operate as high/low temperature distribution centers, with a boiler (or other non-dhw appliance) as a heat source. The CDP0R panels each have two high temperature branches, one for the indirect-fired DHW tank (with priority) and one for the high temperature heating application. The #55 Compact Mixing Control with the -way mixing valve and actuator will automatically regulate the water temperature in the secondary circuit. The panels have three outputs to the boiler. Note: these panels are not compatible with IBC boilers. Panel Components Primary Pump Mixed Temp Pump DHW Pump with Priority High Temp Pump (CDP0RP4R2 only) Power Box Purge Timers on All Circuits Bypass Function Relay Box with 6' Power Cord Terminal Strip 24Vac Plug-in Transformer Compact Reset Control (#55) -Way Mixing Valve with Motor Thermometer Isolation Valve Drain and Fill Valve Panel Enclosure (not shown) Primary Supply Primary Return DHW Return High Temp Return DHW Supply High Temp Supply 2 2 Mixed Temp Return Mixed Temp Supply 2 7 CDP0RP4R2 0 CDP0RPR2 CDP0RP4R2 Listing cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 4"H 7"W 6.75"D Weight 9 lbs 22 lbs Nominal panel output - see conditions below 0,000 Btu/h* Max ambient temperature 20 F Max water temperature 200 F Settable fluid temp range 0-40 F Min required flow for correct temp control US gpm Power supply: pre-wired on system controller 0 V(ac); max. current 6A Primary pump Ferrous, Grundfos UPS26-99FC Low temp pump Ferrous, Grundfos UPS26-99FC DHW pump Non-ferrous, Grundfos UPS5-58 High temp pump optional Non-ferrous, Grundfos UPS5-58 Auxiliary terminal Yes Temperature control method " G -Way mixing valve with motor, controlled by compact reset control. Mix Valve Cv 7. Piping " 04 SS tubing Piping connections " FNPT Backplate 6 gauge galvanized steel Enclosure Powder coated steel CDP0RP & CDP0RP4 Panel Output Conditions Primary Mixed Temp High Temp Nominal output (Btu/h) 255,000 60,000 50,000 Fluid type Water Water Water ΔT ( F) 0 F 20 F 0 F Flow rate (US gpm) 7 US gpm 6 US gpm 0 US gpm Pressure drop (ft head) 7 ft 0 ft 8 ft Special Order* Special Order* CDP0RPR2 CDP0RP4R2 CDP 0MBH 2-Temp Combi DHW with Pumps & Outdoor Reset Rev2 CDP 0MBH 2-Temp Combi DHW with 4 Pumps & Outdoor Reset Rev2 96 * Check with your local representative for availability.

99 Heat/Cool Thermostat Rough-in wiring see: SCH-MRIB-R007 Rough-in wiring see: SCH-MRIB-R004 Outdoor Sensor CDP0RP4R2 Panel Rough-in wiring see: SCH-MRIB-R002 Thermostats T Aquastat Indirect Fired Hot Water Heater Radiant Heating Manifold SCH-CDP-M009 Schematic #: Rough-in wiring see: Boiler CDP0RP4R2 IFHWH, Fan Coil, Radiant Heating Heat Source: Panel(s): Heat Load(s): Wiring detail see: SCH-CDP-E009 Date: Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. Boiler Recommended Pressure Bypass Valve Recommended Sidestream Filter 97

100 Heat Link Solar Heat Exchanger Panel SOL 80 MBH Solar Heat Exchanger Panel Stk# SOL080 Collector Return Collector Supply The SOL080 Heat Exchanger Panel creates an interface between the solar collectors and the system tanks. The Panel integrates all of the control components of a solar system into an attractive compact appliance. Features include a heat exchanger to isolate the glycol in the solar collector circuit from the domestic water, and separate pumps for each circuit. The secondary pump is activated once every 24 hours, for 5 minutes, to ensure that potable water in the piping or heat exchanger is not stagnant Panel Components Mechanical Room in a Box Brazed Plate Heat Exchanger (hidden) Collector Pump Secondary Pump Power Box with 6' Power Cord Timer for Secondary (Tank) Loop Bypass Function Auxiliary Dry Contacts for Heat Source Pressure Relief Valve Pressure Gauge Automatic Air Vent Drain and Fill Valve Solar Control Panel Enclosure (not shown) 9 8 Expansion Tank Secondary Return Pressure Relief Secondary Supply SOL080 Listing cetlus Conforms to CAN CSA-C22 No.4, UL508 Dimensions 8"H 2"W 0-2"D Weight 2.5 lbs. Nominal panel output 80,000 Btu/hr *see conditions to the right Max ambient temperature 20 F Max water temperature 200 F Settable fluid temp range n/a Power supply pre wired on system controller 0 V(ac); max. current 2A Primary pump Non-ferrous, Grundfos UPS5-58 Secondary pump Non-ferrous, Grundfos UPS5-58 Heat exchanger Single-wall Brazed Plate; 8-20 Auxiliary terminal dry contact, max.5a Temperature control method None Piping 4" 04 SS tubing Piping connections " FNPT Backplate 6 gauge galvanized steel Enclosure Powder coated steel Panel Output Conditions Collector Side Secondary Side Fluid type 50% Glycol Water Entering fluid temp ( F) 60 F 5 F Exiting fluid temp ( F) 20 F 50 F Flow rate (US gpm) 5 US gpm 4.5 US gpm Pressure drop (ft head) 4.6 ft.0 ft Allowable pressure drop outside of Panel (ft head) 8 ft 0 ft Special Order* SOL080 SOL 80MBH Solar Heat Exchanger Panel 98 * Lead time may vary. Call to confirm time line.

101 Heat Source: Panel(s): Heat Load(s): Date: SOL080 Panel Storage Tank 80 US gal Cold Water Supply Solar Collector, Generic SOL080 DHW T DHW Supply to House Schematic #: Rough-in wiring see: Wiring detail see: SCH-SOL-M00 SCH-SOL-R00 SCH-SOL-E00 S o l a r C o l l e c t o r Heat Source Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. Secondary Return Secondary Supply 99

102 Heat Link SSM - Stainless Steel Manifold Panels SSM - Stainless Steel Manifold Panels SSM000x Series Mechanical Room in a Box The Stainless Steel Manifold Panel includes: Recessed or surface mount enclosure. Visible parts are made of satin coated steel that is ready to paint without priming. Recessed enclosure depth allows for mounting in a 2 4 wall. One key lock and one or two coin locks. 4, 6, 8, 0, or 2 loop 7600 series SS Manifold with Flow Meters or series High Flow SS Manifold. One loop is closed and plugged. Isolation valves. Thermometer. Optional factory installed add-ons: #7697 Pressure Activated Bypass (SSAPB) #40226 StatLink 6 Zone Base Module with #4425 Installation Track and 24Vac transformer (SSASL). #4024 StatLink 4 Zone Expansion Module (SSASLEM, requires SSASL). #40424 StatLink 2 Zone Heavy Duty Expansion Module (SSASLEMHD, requires SSASL). #5620 Actuator with LED installed on Manifold and wired to StatLink module (SSAACT, requires SSASL). Please contact your local representative for a project quotation. Panel Components Housing 2 Stainless Steel Manifold Thermometer 4 Hose Bib Isolation Ball Valve SSM06R 00

103 Heat Source (e.g. Boiler or Heat Exchanger) SSM Panel SSM Panel Control: Zone Control for Stainless Steel Manifold A. Manual (Default) B. Automatic (Optional) i) HeatLink StatLink 6 Zone Base Module #40226 (SSASL) and HeatLink Actuators #5620 (SSAACT) Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. Heat Source: Panel(s): Heat Load(s): Date: Generic SSM Series Radiant Heating Schematic #: Rough-in wiring see: Wiring detail see: 0

104 Heat Link SSP - SS Manifold Pump Panels SSP - Stainless Steel Manifold Pump Panels SSPxx000x Series Mechanical Room in a Box The Stainless Steel Manifold Pump Panel includes: Recessed or surface mount enclosure. Visible parts are made of satin coated steel that is ready to paint without priming. Recessed enclosure depth allows for mounting in a 2 6 wall. One key lock and one or two coin locks. 4, 6, 8, 0, or 2 loop 7600 series SS Manifold with Flow Meters or series High Flow SS Manifold. One loop is closed and plugged. Pre-wired UPS 5-58 or UPS pump. Top or bottom mains feed available. Isolation valves. Thermometer. Optional factory installed add-ons: #7697 Pressure Activated Bypass (SSAPB) #40226 StatLink 6 Zone Base Module with #4425 Installation Track and 24Vac transformer (SSASL). #4024 StatLink 4 Zone Expansion Module (SSASLEM, requires SSASL). #40424 StatLink 2 Zone Heavy Duty Expansion Module (SSASLEMHD, requires SSASL). #5620 Actuator with LED installed on Manifold and wired to StatLink module (SSAACT, requires SSASL). Please contact your local representative for a project quotation. Panel Components Housing 0V(ac) Power for Pump Pump Thermometer Isolation Valves Stainless Steel Manifold Hosebib SSPSR06T SSPLS06B 02 * Lead time may vary. Call to confirm time line.

105 For all SSP panels, primary piping with circulator must have no pressure differential between panel primary supply and return, i.e. close tees. Heat Source (e.g. Boiler or Heat Exchanger) T SSP Panel SSP Panel Control: Pump Control A. Hardwired 20Vac Power (Default) B. Hardwired switch supplied by others (Optional) C. Hardwired relay supplied by others (Optional) D.BMS System supplied by others (Optional) Zone Control for Stainless Steel Manifold A. Manual (Default) B. Automatic (Optional) i) HeatLink StatLink 6 Zone Base Module #40226 (SSASL) and HeatLink Actuators #5620 (SSAACT) Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. Heat Source: Panel(s): Heat Load(s): Date: Generic SSP Series Radiant Heating Schematic #: Rough-in wiring see: Wiring detail see: SCH-SSP-M00 0

106 Heat Link SSTS - SS Manifold Small Mixing Panels SSTS - Stainless Steel Manifold Mixing Panels with Small Pump SSTSx000x Series Mechanical Room in a Box The Stainless Steel Manifold Mixing Panel includes: Recessed or surface mount enclosure. Visible parts are made of satin coated steel that is ready to paint without priming. Recessed enclosure depth allows for mounting in a 2 6 wall. One key lock and one or two coin locks. 4, 6, 8, 0, or 2 loop 7600 series SS Manifold with Flow Meters or series High Flow SS Manifold. One loop is closed and plugged. -way mixing valve. Pre-wired UPS 5-58 pump. Top or bottom mains feed available. Isolation valves. Thermometer. Optional factory installed add-ons: #7697 Pressure Activated Bypass (SSAPB) Thermostatic head with remote capillary (SSATH). #562 DDC Actuator (SSADDC). #55 Compact Mixing Reset Control (SSAMRC, requires SSADDC). #40226 StatLink 6 Zone Base Module with #4425 Installation Track and 24Vac transformer (SSASL). #4024 StatLink 4 Zone Expansion Module (SSASLEM, requires SSASL). #40424 StatLink 2 Zone Heavy Duty Expansion Module (SSASLEMHD, requires SSASL). #5620 Actuator with LED installed on Manifold and wired to StatLink module (SSAACT, requires SSASL). Please contact your local representative for a project quotation. Panel Components Housing 2 0V(ac) Power for Pump Pump 4 Thermometer -Way Mixing Valve 6 Isolation Valves 7 Stainless Steel Manifold 8 Hosebib SSTSR06T SSTSS06B 04

107 For all SST panels, primary piping with circulator must have no pressure differential between panel primary supply and return, i.e. close tees. Heat Source (e.g. Boiler or Heat Exchanger) T SSTS Panel SSTS Panel Control: Pump Control A. Hardwired 20Vac Power (Default) B. Hardwired switch supplied by others (Optional) C. Hardwired relay supplied by others (Optional) D.BMS System supplied by others (Optional) Mixing Valve Control A. Single Panel - Manual (Default) B. Single Panel - Semi-automatic (Optional) i) Thermostatic Head c/w Capillary (SSATH) C. Single Panel Automatic (Optional) i) HeatLink Compact Mixing Control #55 (SSAMRC) c/w HeatLink DDC Actuator #562 (SSADDC) D. Multiple Panel Automatic (Optional) i) BMS System c/w supply or return sensor supplied by others ii) BMS System with supply sensor supplied by others and HeatLink DDC Actuator #562 (SSADDC) Zone Control for Stainless Steel Manifold A. Manual (Default) B. Automatic (Optional) i) HeatLink StatLink 6 Zone Base Module #40226 (SSASL) and HeatLink Actuators #5620 (SSAACT) Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. Heat Source: Panel(s): Heat Load(s): Date: Generic SSTS Series Radiant Heating Schematic #: Rough-in wiring see: Wiring detail see: SCH-SST-M00 SCH-MRIB-R00 SCH-SST-E00 05

108 Heat Link SSTL - SS Manifold Large Mixing Panels SSTL - Stainless Steel Manifold Mixing Panels with Large Pump SSTLx000x Series Mechanical Room in a Box The Stainless Steel Manifold Mixing Panel includes: Recessed or surface mount enclosure. Visible parts are made of satin coated steel that is ready to paint without priming. Recessed enclosure depth allows for mounting in a 2 6 wall. One key lock and one or two coin locks. 4, 6, 8, 0, or 2 loop 7600 series SS Manifold with Flow Meters or series High Flow SS Manifold. One loop is closed and plugged. -way rotary diverting valve. Pre-wired UPS pump. Top or bottom mains feed available. Isolation valves. Thermometer. Optional factory installed add-ons: #7697 Pressure Activated Bypass (SSAPB) #58 Mixing Valve Motor -Point Floating (SSAMXM). #582 Mixing Valve Motor DDC (SSAMXMDDC). #55 Compact Mixing Reset Control (SSAMRC, requires SSAMXM). #40226 StatLink 6 Zone Base Module with #4425 Installation Track and 24Vac transformer (SSASL). #4024 StatLink 4 Zone Expansion Module (SSASLEM, requires SSASL). #40424 StatLink 2 Zone Heavy Duty Expansion Module (SSASLEMHD, requires SSASL). #5620 Actuator with LED installed on Manifold and wired to StatLink module (SSAACT, requires SSASL). Please contact your local representative for a project quotation. Panel Components Housing 2 0V(ac) Power for Pump Pump 4 Thermometer 5 -Way Diverting Valve 6 Isolation Valves 7 Stainless Steel Manifold 8 Hosebib SSTLR06T SSTLS06B 06

109 For all SST panels, primary piping with circulator must have no pressure differential between panel primary supply and return, i.e. close tees. Heat Source (e.g. Boiler or Heat Exchanger) T SSTL Panel SSTL Panel Control: Pump Control A. Hardwired 20Vac Power (Default) B. Hardwired switch supplied by others (Optional) C. Hardwired relay supplied by others (Optional) D.BMS System supplied by others (Optional) Mixing Valve Control A. Single Panel - Manual (Default) B. Single Panel Automatic (Optional) i) HeatLink Compact Mixing Control #55 (SSAMRC) c/w -Point Floating Mixing Valve Motor #58 (SSAMXM) C. Multiple Panel Automatic (Optional) i) BMS System c/w supply or return sensor supplied by others ii) BMS System with supply sensor supplied by others and DDC Mixing Valve Motor #582 (SSAMXMDDC) Zone Control for Stainless Steel Manifold A. Manual (Default) B. Automatic (Optional) i) HeatLink StatLink 6 Zone Base Module #40226 (SSASL) and HeatLink Actuators #5620 (SSAACT) Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. Heat Source: Panel(s): Heat Load(s): Date: Generic SSTL Series Radiant Heating Schematic #: Rough-in wiring see: Wiring detail see: SCH-SST-M0 SCH-MRIB-R00 SCH-SST-E00 07

110 Heat Link SMP Stainless Steel Snow Melt Panels Stainless Steel Snow Melt Panels SMP000SS Series The Snow Melt Panels are central operations centers for fully automatic snow melt systems with a dedicated heat source (e.g. a boiler or other non-dhw appliance). Includes the primary and secondary pumps, snow melt control, mixing valve, mixing valve motor, plug-in transformer, thermometer, and isolation valves. Snow/Ice Sensor (DRVWSNS-SS) sold separately. See page 6 for Snow Melt Panel Options & Accessories. Mechanical Room in a Box Panel Components Primary Pump Secondary Pump 24Vac Transformer Snow Melt Control -Way Mixing Valve with Motor Supply Sensor Return Sensor Thermometer Isolation Valve Drain and Fill Valve Panel Enclosure (not shown) Primary Supply Primary Return Secondary Return Secondary Supply SMP75SS SMP75SSH Listing SMP75SS cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 0.88"H 8.4"W 8.027"D Weight 75 lb 80 lb Nominal panel output* 00,000 BTU 75,000 BTU Nominal flow* 20 US 40 F ΔT 25 US 40 F ΔT Nominal pressure drop outside of panel* 0 ft 8 ft Max ambient temperature 20 F Max water temperature 200 F Temperature control range 50 F to 80 F Max allowable operating pressure on secondary side 00 psi Power supply: pre-wired on system controller Module with 20v plug & 6' cord. Requires dedicated receptacle, 5 Amp, 20V, 60Hz, single phase. Primary pump Grundfos UPS 26-99FC Secondary pump Grundfos UPS 26-99FC Grundfos UPS 26-50FC Temperature control method - 4" G -way diverting valve and motor, controlled by snow melt control. Mix Valve Cv.6 Auxiliary terminal dry contact, max 6A Piping " 04 SS tubing Piping connections " FNPT Backplate and sides 6 gauge galvanized steel Cover Powder coated steel 9 9 SMP75SS Special Order* Special Order* SMP75SS SMP75SSH SMP 00MBH SS Snow Melt Panel (No HEX; DRVWSNS-SS sold sep) SMP 75MBH SS Snow Melt Panel with HH Pump (No HEX; DRVWSNS-SS sold sep) 08 * Lead time may vary. Call to confirm time line.

111 Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. Heat Source: Panel(s): Heat Load(s): Schematic #: Rough-in wiring see: SMP000SS Panel Wiring detail see: T Boiler Snow/Ice Detector (DRVWSNS-SS) SCH-SMP-M002 SCH-SMP-R002 Boiler SMP000SS Series Snow Melt Date: SCH-SMP-E002 09

112 Heat Link SMP Stainless Steel Snow Melt Panels with Heat Exchangers Stainless Steel Snow Melt Panels with Heat Exchangers SMP000SS-HEX Series The Snow Melt Panels are central operations centers for fully automatic snow melt systems requiring isolation. Includes the primary and secondary pumps, heat exchangers, snow melt control, mixing valve, mixing valve motor, plug-in transformer, thermometer, and isolation valves. Snow/Ice Sensor (DRVWSNS-SS) sold separately. See page 6 for Snow Melt Panel Options & Accessories. Mechanical Room in a Box Panel Components Primary Pump 2 Secondary Pump Heat Exchanger 4 24Vac Transformer 5 Snow Melt Control 6 -Way Mixing Valve with Motor 7 Supply Sensor 8 Return Sensor 9 Thermometer 0 Isolation Valve Drain and Fill Valve Pressure Relief Valve Panel Enclosure (not shown) 2 Primary Supply Primary Return SMP00SS-HEX Secondary Return Secondary Supply Expansion Tank Pressure Relief SMP75SS-HEX SMP00SS-HEX SMP00-HEX-H Listing cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 0.88"H 8.4"W 8.027"D Weight 9.5 lb TBD TBD Nominal panel output (see conditions below) 75,000 BTU 00,000 BTU 65,000 BTU Max ambient temperature 20 F Max water temperature 200 F Temperature control range 50 F to 80 F Max allowable operating pressure on secondary side 00 psi Power supply: pre-wired on system controller Module with 20v plug & 6' cord. Requires dedicated receptacle, 5 Amp, 20V, 60Hz, single phase. Primary pump Grundfos UPS 26-99FC Secondary pump Grundfos UPS 26-99FC Grundfos UPS 26-50FC Temperature control method - 4" G -way diverting valve and motor, controlled by snow melt control. Mix Valve Cv.6 Heat Exchanger 2 Single-wall brazed plate; Single-wall brazed plate; 8-0 Single-wall brazed plate; 8-0 Auxiliary terminal dry contact, max 6A Piping " 04 SS tubing Piping connections " FNPT Backplate and sides 6 gauge galvanized steel Cover Powder coated steel SMP75SS-HEX SMP00SS-HEX SMP00SS-HEX-H Panel Output Conditions Primary Secondary Primary Secondary Primary Secondary Fluid type Water 50% glycol Water 50% glycol Water 50% glycol Entering fluid temp ( F) Exiting fluid temp ( F) Flow rate (US gpm) Headloss Allowable pressure drop outside of panel (ft head) Special Order* Special Order* Special Order* SMP75SS-HEX SMP00SS-HEX SMP00SS-HEX-H SMP 75MBH SS Snow Melt Panel 2 20 HEX (DRVWSNS-SS sold sep) SMP 00MBH SS Snow Melt Panel 2 0 HEX (DRVWSNS-SS sold sep) SMP 65MBH SS Snow Melt Panel 0 HEX & HH Pump (DRVWSNS-SS sold sep) 0 * Lead time may vary. Call to confirm time line.

113 Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. SMP000SS-HEX Panel Heat Source: Panel(s): Heat Load(s): Date: Schematic #: Rough-in wiring see: Wiring detail see: T Boiler Extend pressure relief pipe to within 6" of floor. Boiler SMP000SS-HEX Series Snow Melt Snow/Ice Detector (DRVWSNS-SS) SCH-SMP-M004 SCH-SMP-R002 SCH-SMP-E002

114 Heat Link SMP Copper Snow Melt Panel SMP 400 MBH Snow Melt Panel without Heat Exchangers Stk# SMP400D The SMP400D Snow Melt Panel is a central operations center for a fully automatic snow melt system with a dedicated heat source (e.g. a boiler or other non-dhw appliance). Includes the secondary pump, snow melt control, mixing valve, mixing valve motor, transformer, thermometer, pressure gauges, air eliminator, balancing valves, and isolation valves. Snow/Ice Sensor (DRVWSNS-SS) sold separately. See page 6 for Snow Melt Panel Options & Accessories. Mechanical Room in a Box Panel Components Secondary Pump Air Eliminator 24Vac Transformer Snow Melt Control -Way Diverting Valve with Motor Supply Sensor (not shown) Return Sensor (not shown) Thermometer (not shown) Pressure Gauge Balancing Valve Isolation Valve Panel Enclosure and Cover (not shown) Secondary Return Secondary Supply Expansion Tank System Feed Primary Return Primary Supply SMP400D Listing cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 6"H 48"W 6"D Weight 480 lbs. Nominal panel output 400,000 btu/hr Nominal flow 2 US 25 F ΔT Nominal pressure drop outside of panel 25 ft Max ambient temperature 20 F Max water temperature 200 F Settable fluid temp range 50 F to 80 F Max allowable operating pressure on secondary side 00 psi Power supply: pre-wired on system controller Module with 20v plug & 6' cord. Requires dedicated receptacle, 5 Amp, 20V, 60Hz, single phase. Pump Grundfos UP4-0 Temperature control method - 4" FNPT -way diverting valve and motor, controlled by snow melt control. Mix Valve Cv 8.6 Auxiliary terminal dry contact, max 6A Piping - 2" Copper Piping connections - 2" FNPT Expansion tank fitting 2" FNPT Cold water fill 4" hose bib Backplate and sides 6 gauge galvanized steel Cover Powder coated steel Special Order* SMP400D SMP 400MBH Copper Snow Melt Panel (No HEX; DRVWSNS-SS sold sep) 2 * Lead time may vary. Call to confirm time line.

115 T P P Snow/Ice Detector (DRVWSNS-SS) Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. SMP400D Panel System Feed Heat Source: Panel(s): Heat Load(s): Boiler SMP400D Snow Melt Date: P Boiler Schematic #: Rough-in wiring see: Wiring detail see: SCH-SMP-M00 SCH-SMP-R002 SCH-SMP-E00

116 Heat Link SMP Copper Snow Melt Panels with Heat Exchangers SMP MBH Snow Melt Panels with Heat Exchangers SMP000 Series The SMP5-425 Snow Melt Panels are central operations centers for fully automatic snow melt systems requiring isolation. Includes the secondary pump, snow melt control, mixing valve, mixing valve motor, transformer, thermometer, pressure gauges, heat exchangers, air eliminator, balancing valves, and isolation valves. Snow/Ice Sensor (DRVWSNS-SS) sold separately. See page 6 for Snow Melt Panel Options & Accessories. Mechanical Room in a Box Panel Components Secondary Pump 2 Air Eliminator Heat Exchanger 24Vac Transformer 5 Snow Melt Control 6 -Way Diverting Valve with Motor 7 Supply Sensor Return Sensor 9 Thermometer 0 Pressure Gauge Automatic Air Vent 2 Strainer Balancing Valve 4 Isolation Valve 5 Drain and Fill Valve 6 Pressure Relief Valve Panel Cover (not shown) Secondary Return 2 Secondary Supply 4 SMP5 Expansion Tank SMP5 SMP425 Listing cetlus Conforms to CAN/CSA-C22 No.4, UL508 Dimensions 6"H 48"W 6"D Weight 500 lbs. Nominal panel output - see conditions below 5,000 btu/hr 425,000 btu/hr Max ambient temperature 20 F Max water temperature 200 F Settable fluid temp range 50 F to 80 F Max allowable operating pressure on secondary side 00 psi Power supply: pre-wired on system controller Module with 20v plug & 6' cord. Requires dedicated receptacle, 5 Amp, 20V, 60Hz, single phase. Circulator Grundfos UP4-0 Temperature control method - 4" FNPT -way diverting valve and motor, controlled by snow melt control. Mix valve Cv 8.6 Heat exchanger size Auxiliary terminal dry contact, max 6A Piping - 2" Copper Piping connections - 2" FNPT Expansion tank fitting 2" FNPT Cold water fill 4" hose bib Backplate and sides Galvanized steel Cover Powder coated steel System Feed 6 Primary Return Primary Supply SMP5 SMP425 Panel Output Conditions Primary Secondary Primary Secondary Fluid type Water 50% glycol Water 50% glycol Entering fluid temp ( F) Exiting fluid temp ( F) Flow rate (US gpm) Headloss Pressure drop (ft head) 22 2 Special Order* Special Order* SMP5 SMP425 SMP 5MBH Copper Snow Melt Panel 4 20 Plate HEX (DRVWSNS-SS sold sep) SMP 425MBH Copper Snow Melt Panel 4 0 Plate HEX (DRVWSNS-SS sold sep) 4 * Lead time may vary. Call to confirm time line.

117 SMP5/SMP425 Panel P P Notes: Drawings are for HeatLink suggested system layout only! User must determine if system layout will work for their particular application. Air vents, expansion tanks, pressure relief valves, etc. for heat source as per local codes. Use isolation ball valves for all circuits and components. Local codes, regulations, and authorities have final jurisdiction. Heat Source: Panel(s): Heat Load(s): Date: Schematic #: Rough-in wiring see: Wiring detail see: T System Feed Extend pressure relief pipe to within 6" of floor. Snow/Ice Detector (DRVWSNS-SS) Boiler SMP5/SMP425 Snow Melt Boiler Cold Water Supply SCH-SMP-M00 SCH-SMP-R002 SCH-SMP-E00 5

118 Heat Link SMP Snow Melt Panel Options & Accessories Snow/Ice Detector (Sensor) Stk# DRVWSNS-SS This snow/ice sensor in conjunction with the standard snow melt panel control, ac ti vates and con trols a snow melting system based on moisture (snow/ice) and slab temperature. DRVWSNS-SS Driveway Sensor for SMP Panels Mechanical Room in a Box Special Order* Replace SMP Control with 667 Snow/Ice Detector and Melt Control Stk# SMP667 Replaces the standard snow melt panel control with 667 Snow/Ice Detector and Melt Control. The snow melting system may be started manually or automatically through the use of a Snow/Ice Sensor (0090). SMP667 Replace SMP Control With #667 Snow/Ice Detector & Melt Control Snow/Ice Detector (Sensor) Stk# 0090, 009 This snow/ice sensor in conjunction with the 667, ac ti vates and con trols a snow melting system based on moisture (snow/ice) and slab tem per a ture. This control is not designed as a simple de tec tion device and will not operate properly in an unheated slab. For use with snow melt panels using 667 control Snow/Ice Sensor (0K) 65 ft cable 009 Snow/Ice Sensor Socket 6 * Lead time may vary. Call to confirm time line.

119 Heat Link PureLink Potable Water PEX-a Tubing PureLink Plus Blue Stripe PEX-a Tubing - Coils Series High molecular crosslinked polyethylene (PEX) with minimum bending radius of 6 the diameter at 68 F (20 C). Maximum operating temperature psi (82 7 bar). Blue printing on 2 sides for identification of cold water lines. Meets or exceeds ASTM F876/F877/F202, ASTM E84, CSA B7.5, cnsfus-pw, NSF/ANSI-6, NSF/ANSI-4, Annex G, NSF U.P.Code, ICC-ES, ICC-PMG, ULC S , IAPMO UPC ( 2"), PPI TR-4. The PureLink Plus PEX-a tubing may also be used with fittings that are compliant with ASTM F807/F960/F2080/F2098/F259 standards. Minimum bending 68 F (20 C) for: 2" = " (77 mm) 4" = 4-2" (5 mm) " = 6" (5 mm) Stk# Description Pkg Qty Carton Skid Qty Unit List Price / Unit " 00ft Blue PureLink Plus UV Stabilized PEX-a PexCube 6 48 coil " 00ft Blue PureLink Plus UV Stabilized PEX-a Tubing 2 coil " 500ft Blue PureLink Plus UV Stabilized PEX-a Tubing 20 coil " 000ft Blue PureLink Plus UV Stabilized PEX-a Tubing 4 coil " 00ft Blue PureLink Plus UV Stabilized PEX-a PexCube 48 coil " 00ft Blue PureLink Plus UV Stabilized PEX-a Tubing 4 coil " 500ft Blue PureLink Plus UV Stabilized PEX-a Tubing 9 coil " 000ft Blue PureLink Plus UV Stabilized PEX-a Tubing 5 coil 2028 " 00ft Blue PureLink Plus UV Stabilized PEX-a Tubing 9 coil 2028 " 00ft Blue PureLink Plus UV Stabilized PEX-a Tubing 9 coil For sizes - 4" and larger, please see page 9. Stk# Description Description Pkg Qty Pkg Master Qty Bag Carton Qty Unit Unit Disc. List Price / Unit New! " 25 2ft Blue PureLink Plus UV Stabilized PEX-a Tubing 20 bundle " 20 20ft Blue PureLink Plus UV Stabilized PEX-a Tubing 20 bundle New! " 0 2ft Blue PureLink Plus UV Stabilized PEX-a Tubing 20 bundle " 0 20ft Blue PureLink Plus UV Stabilized PEX-a Tubing 20 bundle New! " 5 2ft Blue PureLink Plus UV Stabilized PEX-a Tubing 20 bundle " 5 20ft Blue PureLink Plus UV Stabilized PEX-a Tubing 20 bundle For sizes - 4" and larger, please see page 9. Potable Water System 7

120 Heat Link PureLink Potable Water PEX-a Tubing PureLink Plus Red Stripe PEX-a Tubing 2000 Series High molecular crosslinked polyethylene (PEX) with minimum bending radius of 6 the diameter at 68 F (20 C). Maximum operating temperature psi (82 7 bar). Red printing on 2 sides for identification of hot water lines. Meets or exceeds ASTM F876/F877/F202, ASTM E84, CSA B7.5, cnsfus-pw, NSF/ANSI-6, NSF/ANSI-4, Annex G, NSF U.P.Code, ICC-ES, ICC-PMG, ULC S , IAPMO UPC ( 2"), PPI TR-4. The PureLink Plus PEX-a tubing may also be used with fittings that are compliant with ASTM F807/F960/F2080/F2098/F259 standards. Minimum bending 68 F (20 C) for: 2" = " (77 mm) 4" = 4-2" (5 mm) " = 6" (5 mm) Potable Water System Stk# Description Pkg Qty Carton Skid Qty Unit List Price / Unit 205 2" 00ft Red PureLink Plus UV Stabilized PEX-a PexCube 6 48 coil 205 2" 00ft Red PureLink Plus UV Stabilized PEX-a Tubing 2 coil " 500ft Red PureLink Plus UV Stabilized PEX-a Tubing 20 coil " 000ft Red PureLink Plus UV Stabilized PEX-a Tubing 4 coil 222 4" 00ft Red PureLink Plus UV Stabilized PEX-a PexCube 48 coil 222 4" 00ft Red PureLink Plus UV Stabilized PEX-a Tubing 4 coil " 500ft Red PureLink Plus UV Stabilized PEX-a Tubing 9 coil WSL " 000ft Red PureLink Plus UV Stabilized PEX-a Tubing 5 coil 228 " 00ft Red PureLink Plus UV Stabilized PEX-a Tubing 9 coil 228 " 00ft Red PureLink Plus UV Stabilized PEX-a Tubing 9 coil For sizes - 4" and larger, please see page 9. Stk# Description Pkg Qty Master Carton Qty Bag Unit List Price / Unit New! " 25 2ft Red PureLink Plus UV Stabilized PEX-a Tubing 20 bundle " 20 20ft Red PureLink Plus UV Stabilized PEX-a Tubing 20 bundle New! " 0 2ft Red PureLink Plus UV Stabilized PEX-a Tubing 20 bundle " 0 20ft Red PureLink Plus UV Stabilized PEX-a Tubing 20 bundle 2228 " 5 20ft Red PureLink Plus UV Stabilized PEX-a Tubing 20 bundle For sizes - 4" and larger, please see page 9. 8

121 Heat Link PureLink Potable Water PEX Tubing PureLink Plus Large Dimension PEX-a Tubing Series High molecular crosslinked polyethylene (PEX) with minimum bending radius of 6 the diameter at 68 F (20 C). Maximum operating temperature psi (82 7 bar). Black printing on 2 sides. Meets or exceeds ASTM F876/F877/F202, ASTM E84, CSA B7.5, cnsfus-pw, NSF/ANSI-6, NSF/ANSI-4, Annex G, NSF U.P.Code, ICC-ES, ICC-PMG, ULC S , PPI TR-4. The PureLink Plus PEX-a tubing may also be used with fittings that are compliant with ASTM F807/ F960/F2080/F2098/F259 standards. Minimum bending 68 F (20 C) for: - 4" = 7-2" (9 mm) - 2" = 9" (229 mm) 2" = 2" (05 mm) Stk# Description Pkg Qty Carton Skid Qty Unit List Price / Unit 205-4" 00ft PureLink Plus UV Stabilized PEX-a Tubing 7 coil 205-4" 00ft PureLink Plus UV Stabilized PEX-a Tubing 5 coil " 00ft PureLink Plus UV Stabilized PEX-a Tubing 5 coil " 00ft PureLink Plus UV Stabilized PEX-a Tubing 5 coil New! " 00ft PureLink Plus UV Stabilized PEX-a Tubing 5 coil New! " 00ft PureLink Plus UV Stabilized PEX-a Tubing coil Stk# Description Pkg Qty Master Carton Bag Qty Unit List Price / Unit New! " 5 2ft PureLink Plus UV Stabilized PEX-a Tubing 20 bundle " 5 20ft PureLink Plus UV Stabilized PEX-a Tubing 20 bundle " 5 20ft PureLink Plus UV Stabilized PEX-a Tubing 5 bundle New! " 5 20ft PureLink Plus UV Stabilized PEX-a Tubing 5 bundle Potable Water System 9

122 Pure Link Pipe-in-Pipe Never again deal with the hassle of trying to pull tubing through conduits. Our pliable PEX-a tubing is available in a high impact resistant sheath. 4" PureLink Pipe-in-Pipe 2" PureLink Pipe-in-Pipe Basin Feed plumbing fixtures in buildings of all sizes. Allows for insertion and withdrawal of inner PEX-a tubing for perpetual access. Toilet Bathtub

123 Heat Link PureLink Pipe-in-Pipe PureLink Plus Pipe-in-Pipe Sheathed Series PEX-a carrier tubing specified on previous pages. The flexible, impact resistant PE sheath designed as a raceway for electrical installations provides mechanical and UV protection to the PEX-a carrier tubing. The sheath allows for easy replacement of the PEX-a carrier tubing if needed. Red and Blue colored sheaths make for easy identification of hot and cold water lines. PEX-a carrier tubing meets or exceeds ASTM F876/F877/F202, CSA B7.5, cnsfus-pw, NSF/ANSI-6, NSF/ANSI-4, Annex G, NSF U.P.Code, ICC-ES, ICC-PMG, IAPMO UPC ( 2"), PPI TR-4. The PureLink Plus PEX-a tubing may also be used with fittings that are compliant with ASTM F807/F960/F2080/F2098/F259 standards. Minimum bending 68 F (20 C) for: 2" = " (77 mm) 4" = 4-2" (5 mm) " = 6" (5 mm) PE sheath is rated to UL94HB Tests for Flammability of Plastic Materials. Corrugated sheath outside diameter for: 2" = 5 6" (2 mm) 4" = - 8" (5 mm) " = - 2" (7 mm) Stk# Description Pkg Qty Carton Skid Qty Unit List Price / Unit 9205bs 2" 00ft Blue PureLink Plus Pipe-in-Pipe 27 coil 9205bs 2" 00ft Blue PureLink Plus Pipe-in-Pipe 4 coil 9222bs 4" 00ft Blue PureLink Plus Pipe-in-Pipe 2 8 coil 9222bs 4" 00ft Blue PureLink Plus Pipe-in-Pipe 9 coil 9228bs " 00ft Blue PureLink Plus Pipe-in-Pipe 7 coil Stk# Description Pkg Qty Carton Skid Qty Unit List Price / Unit 9205rs 2" 00ft Red PureLink Plus Pipe-in-Pipe 27 coil 9205rs 2" 00ft Red PureLink Plus Pipe-in-Pipe 4 coil 9222rs 4" 00ft Red PureLink Plus Pipe-in-Pipe 2 8 coil 9222rs 4" 00ft Red PureLink Plus Pipe-in-Pipe 9 coil 9228rs " 00ft Red PureLink Plus Pipe-in-Pipe 7 coil Potable Water System 2

124 Heat Link EasyFit Manifold Compression Stop Tee Stk# 2200 The potable water module complete with shut-off. Order shut-off cap (#2280 & #228) and PEX insert style, tubing to manifold connecters (#2000 series) separately. There are 4 shrink-wrapped packages of 5 modules per box Compression Stop Tee 20 ea. EasyFit 2-Port Tee Stk# A 2-port tee with 2" EasyFit connections. Includes 2 nuts EasyFit 2-Port Tee 50 ea. Potable Water System EasyFit -Port Tee Stk# 2200 A -port tee with 2" EasyFit connections. Includes nuts EasyFit -Port Tee 50 ea. Mounting Bracket Stk# 222 Plastic mounting brackets which allow easy snap-on mounting of manifolds. 222 EasyFit Single Mounting Bracket 0 ea. 22

125 Heat Link EasyFit Manifold Components Red & Blue Shut-off Caps Stk# 2280, 228 Red (#2280) and blue (#228) colored caps for use with Potable Module Tee with Compression Stop (#2200). No tools required Red Shut-off Cap 0 ea. 228 Blue Shut-off Cap 0 ea. 2" EasyFit Supply End Connection Stk# 229 O-ring sealing end piece with 2" EasyFit connection. Comes with o-ring " EasyFit Supply End Connection 0 ea. 4" EasyFit Supply End Connection Stk# 2294 O-ring sealing end piece with 4" EasyFit connection. Comes with o-ring " EasyFit Supply End Connection 0 ea. Closed End Cap Stk# 2299 O-ring sealing end piece EasyFit Manifold Closed End Cap 0 ea. Potable Water System 4" EasyFit Run End Connection Stk# 2295 O-ring sealing end piece with 4" EasyFit connection. Comes with o-ring " EasyFit Run End Connection 0 ea. 2

126 Heat Link EasyFit Manifold Components EasyFit 2" Outlet Cap with o-ring Stk# 2055 Plastic cap with o-ring to seal unused outlet of #22002 & # " EasyFit Outlet Cap with O-ring 0 ea. Tubing to Manifold Connecters 2000 Series Plastic fitting is installed into the bottom of the manifold module and is held in place by the nut. The tubing is then pressed on to this fitting. SS press sleeves sold separately. For use with Compression Stop Tee # " PEX Insert Manifold Connecter 5 ea " PEX Insert Manifold Connecter c/w Nut 5 ea. Non-Toxic Silicone O-Ring Lubricant Stk# 7995 & Lubrication for the manifold o-rings. Non-toxic silicone grease. Highly recommended for trouble free installation of manifold components. Potable Water System g Bottle Non-toxic Silicone O-ring Lubricant g Bottle Non-toxic Silicone O-ring Lubricant 24

127 Heat Link HPP Multiport Tees 20 Closed End HPP Multiport Tee 000 Series Closed one end and 4" or " PEX insert on the other end. 2" branches in single row or opposing rows. SS press sleeves sold separately Port Single Row, 4" PEX Closed End HPP Multiport Tee 4 Port Single Row, 4" PEX Closed End HPP Multiport Tee 6 Port Single Row, 4" PEX Closed End HPP Multiport Tee 8 Port Single Row, 4" PEX Closed End HPP Multiport Tee 6 Port Single Row, " PEX Closed End HPP Multiport Tee 8 Port Single Row, " PEX Closed End HPP Multiport Tee 6 Port Opposing Rows, " PEX Closed End HPP Multiport Tee 8 Port Opposing Rows, " PEX Closed End HPP Multiport Tee Flow Through HPP Multiport Tee 4000 Series 5 50 ea ea ea ea ea ea ea ea Open on both ends with 4" or " PEX insert connections. 2" branches in single row or opposing rows. SS press sleeves sold separately Port Single Row, 4" PEX 4" PEX Flow Through HPP Multiport Tee 4 Port Single Row, 4" PEX 4" PEX Flow Through HPP Multiport Tee Port Single Row, " PEX 4" PEX Flow Through HPP Multiport Tee 4 Port Single Row, " PEX 4" PEX Flow Through HPP Multiport Tee 6 Port Single Row, " PEX 4" PEX Flow Through HPP Multiport Tee 8 Port Single Row, " PEX 4" PEX Flow Through HPP Multiport Tee 6 Port Opposing Rows, 4" PEX 4" PEX Flow Through HPP Multiport Tee 8 Port Opposing Rows, 4" PEX 4" PEX Flow Through HPP Multiport Tee 6 Port Opposing Rows, " PEX 4" PEX Flow Through HPP Multiport Tee 8 Port Opposing Rows, " PEX 4" PEX Flow Through HPP Multiport Tee 5 50 ea ea ea ea ea ea ea ea ea ea. Potable Water System 25

128 Heat Link Stainless Steel Press Sleeves Making a Lasting Impression Press Sleeve HeatLink Potable Water Systems now offers a start-to-finish system capped off with the unique PEX tubing watertight connection the stainless steel Press Sleeve. The Press Sleeve slides over the outer part of the PEX-a tubing, before inserting the fitting. When the fitting is in place, the press tool secures the connection in one single press, evidenced by a smooth visible depression ring on the sleeve's surface. non-pressed No crimp gauge is required with a Press Sleeve, thus eliminating a step in the whole installation procedure. Once the pressing is complete, everything is set for the pressure test. The room for error is reduced, as the visible impression on the sleeve indicates readiness for the pressure test. pressed (press profile may vary with tool) HeatLink's Press Sleeve an impressive connection to have in any pressing situation. The SS Press Sleeve is tested to ASTM F877 and is NSF-pw listed. Potable Water System Stainless Steel Press Sleeves Series Press sleeve with view hole " SS Press Sleeve ea " SS Press Sleeve ea " SS Press Sleeve ea " SS Press Sleeve 0 50 ea " SS Press Sleeve 0 00 ea. New! " SS Press Sleeve 0 00 ea. 26

129 Heat Link HPP Fitting System The HeatLink High Performance Polymer (HPP) fitting system is produced from a specific blend of engineered high performance polyphenylsulfone (PPSU) resins. When combined, these resins offer outstanding long-term performance and chemical resistance. The sulfone family of resins began to replace brass in the plumbing industry over 20 years ago, and in the course of time have exceeded the stringent demands of the potable and heating industries. O S O O O n Figure # General Chemical Structure of PPSU The HeatLink HPP fittings standout in the market place due to a unique combination of characteristics designed to deliver superior performance. Outstanding resistance to hot chlorinated water Superior long-term hydrostatic strength Excellent thermal stability High resistance to mineral acids, alkali, and salt solutions Higher resistance to polar solvents and stress cracking than traditional polysulfone Robust toughness and impact strength Exceptional hydrolytic stability Improved notch resistance

130 Heat Link PEX Insert Couplings No Lead PEX Insert Couplings - No Lead Brass 29000NL Series Solid no lead brass (C6900-ecobrass) PEX insert PEX insert couplings. SS press sleeves sold separately. New! 29005NL 2" 2" PEX No Lead Brass Coupling ea. New! 29022NL 4" 4" PEX No Lead Brass Coupling ea. New! 29028NL " " PEX No Lead Brass Coupling 5 00 ea. 2905NL - 4" - 4" PEX No Lead Brass Coupling 5 80 ea. 2904NL - 2" - 2" PEX No Lead Brass Coupling 5 90 ea. New! 29054NL 2" 2" PEX No Lead Brass Coupling 5 25 ea. No Lead PEX Insert Reducing Couplings - No Lead Brass 29200NL Series Solid no lead brass (C6900-ecobrass) PEX insert PEX insert reducing couplings. SS press sleeves sold separately. New! 29225NL 4" 2" PEX No Lead Brass Coupling ea. New! 29282NL " 4" PEX No Lead Brass Coupling 5 0 ea. 2928NL - 4" " PEX No Lead Brass Coupling ea NL - 2" " PEX No Lead Brass Coupling 5 00 ea. New! 2924NL - 2" - 4" PEX No Lead Brass Coupling 5 50 ea. New! 2926NL 2" - 4" PEX No Lead Brass Coupling 5 25 ea. New! 29264NL 2" - 2" PEX No Lead Brass Coupling 5 25 ea. Potable Water System PEX Insert Couplings - HPP 9000 Series High Performance Polymer PEX insert couplings. SS press sleeves sold separately " 2" PEX HPP Coupling ea " 4" PEX HPP Coupling ea " " PEX HPP Coupling ea. PEX Insert Reducing Couplings - HPP 9200 Series High Performance Polymer PEX insert reducing couplings. SS press sleeves sold separately " 2" PEX HPP Coupling ea " 4" PEX HPP Coupling 5 00 ea. 28

131 Heat Link PEX Insert Elbows No Lead PEX Insert Elbows - No Lead Brass 28000NL Series Solid no lead brass (C6900-ecobrass) PEX insert PEX insert elbows. SS press sleeves sold separately. New! 28005NL 2" 2" PEX No Lead Brass Elbow ea. New! 28022NL 4" 4" PEX No Lead Brass Elbow ea. New! 28028NL " " PEX No Lead Brass Elbow 5 80 ea. 2805NL - 4" - 4" PEX No Lead Brass Elbow 5 20 ea. 2804NL - 2" - 2" PEX No Lead Brass Elbow 5 50 ea. New! 28054NL 2" 2" PEX No Lead Brass Elbow 5 25 ea. No Lead PEX Insert Reducing Elbows - No Lead Brass 28200NL Series Solid no lead brass (C6900-ecobrass) PEX insert PEX insert reducing elbows. SS press sleeves sold separately. New! 28225NL 4" 2" PEX No Lead Brass Elbow ea. PEX Insert Elbows - HPP 8000 Series High Performance Polymer PEX insert elbows. SS press sleeves sold separately " 2" PEX HPP Elbow ea " 4" PEX HPP Elbow ea " 2" PEX HPP Elbow ea " " PEX HPP Elbow 0 50 ea. Potable Water System 29

132 Heat Link PEX Insert Threaded Elbows No Lead PEX Insert MNPT Elbows - No Lead Brass 28500NL Series Solid no lead brass (C6900-ecobrass) PEX insert elbows. SS press sleeves sold separately. 2858NL " PEX - 4" MNPT No Lead Brass Elbow 5 60 ea. 2855NL - 4" PEX - 4" MNPT No Lead Brass Elbow 5 50 ea. PEX Insert MNPT Elbows - HPP 8500 Series High Performance Polymer PEX insert elbows. SS press sleeves sold separately " PEX 8" MNPT HPP Dishwasher Elbow ea " PEX 2" MNPT HPP Elbow ea. Potable Water System 0

133 Heat Link PEX Insert FNPT Adapters No Lead Drop Ear Elbows - No Lead Brass 2800NL Series Solid no lead brass (C6900-ecobrass) 2" PEX insert 2" FNPT drop ear elbow. SS press sleeves sold separately. 282NL 2" PEX 8" FNPT Drop Ear No Lead Brass Elbow 0 80 ea. 2805NL 2" PEX 2" FNPT Drop Ear No Lead Brass Elbow 0 60 ea. No Lead PEX Insert FNPT Adapters - No Lead Brass 27600NL Series Solid no lead brass (C6900-ecobrass) PEX insert FNPT adapters. SS press sleeves sold separately. Sept 204 Sept NL 2" PEX 2" FNPT No Lead Brass Adapter ea NL 4" PEX 4" FNPT No Lead Brass Adapter ea NL " PEX " FNPT No Lead Brass Adapter ea. 2762NL - 4" PEX 4" FNPT No Lead Brass Adapter 5 ea. 2765NL - 4" PEX - 4" FNPT No Lead Brass Adapter 5 80 ea. 2768NL - 4" PEX " FNPT No Lead Brass Adapter 5 ea. 2764NL - 2" PEX - 2" FNPT No Lead Brass Adapter 5 50 ea. Potable Water System

134 Heat Link PEX Insert Fixture Adapters PEX Insert FNPT Swivel Adapters - HPP 7700 Series High Performance Polymer PEX insert FNPT swivel adapters. SS press sleeves sold separately " PEX 2" FNPT Swivel HPP Adapter 25 ea " PEX Ballcock/Closet FNPT Swivel HPP Adapter ea " PEX 4" FNPT Swivel HPP Adapter ea. PEX Insert FNPT Swivel Elbow Adapter - HPP Stk# 8605 High Performance Polymer PEX insert FNPT swivel elbow adapters. SS press sleeves sold separately " PEX 2" FNPT HPP Swivel Elbow ea. Potable Water System No Lead 2" PEX 8" O.D. Comp. Straight Lav. Tube Adapter - NL Brass Stk# 2575NL Solid no lead brass (C6900-ecobrass) adapter for connecting faucets. SS press sleeves sold separately. New! 2575NL 2" PEX 8" O.D. No Lead Brass Adapter ea. 2

135 Heat Link PEX Insert MNPT Adapters No Lead PEX Insert MNPT Adapters - No Lead Brass 27500NL Series Solid brass no lead (C6900-ecobrass) PEX insert MNPT adapters. SS press sleeves sold separately. New! 27505NL 2" PEX 2" MNPT No Lead Brass Adapter ea. New! 27552NL 2" PEX 4" MNPT No Lead Brass Adapter ea. New! 27522NL 4" PEX 4" MNPT No Lead Brass Adapter 0 60 ea NL " PEX " MNPT No Lead Brass Adapter 0 50 ea NL " PEX 4" MNPT No Lead Brass Adapter ea. 2755NL - 4" PEX - 4" MNPT No Lead Brass Adapter 5 00 ea. 2758NL - 4" PEX " MNPT No Lead Brass Adapter 5 00 ea. 2754NL - 2" PEX - 2" MNPT No Lead Brass Adaptor 5 50 ea. New! 27554NL 2" PEX 2" MNPT No Lead Brass Adapter 5 25 ea. PEX Insert MNPT Adapters - HPP 7500 Series High Performance Polymer PEX insert MNPT adapters. SS press sleeves sold separately " PEX 2" MNPT HPP Adapter ea " PEX 4" MNPT HPP Adapter ea " PEX 4" MNPT HPP Adapter ea " PEX 2" MNPT HPP Adapter ea. Potable Water System

136 Heat Link PEX Insert Sweat Adapters and Tees No Lead PEX Insert Sweat Adapters - No Lead Brass 2700NL & 27200NL Series Solid no lead brass (C6900-ecobrass) PEX insert sweat adapters. SS press sleeves sold separately. 2705NL 2" PEX 2" M/Sweat No Lead Brass Adapter ea NL 2" PEX 2" F/Sweat No Lead Brass Adapter ea. 2722NL 4" PEX 4" M/Sweat No Lead Brass Adapter ea NL 4" PEX 4" F/Sweat No Lead Brass Adapter ea. New! 2728NL 4" PEX " F/Sweat No Lead Adapter ea. 2728NL " PEX " M/Sweat No Lead Brass Adapter ( 4" F/ Sweat) ea NL " PEX " F/Sweat No Lead Brass Adapter ea. 275NL - 4" PEX - 4" M/Sweat No Lead Brass Adapter 5 20 ea. 2725NL - 4" PEX - 4" F/Sweat No Lead Brass Adapter 5 20 ea. 274NL - 2" PEX - 2" M/Sweat No Lead Brass Adapter 5 80 ea. New! 2754NL 2" PEX 2" M/Sweat No Lead Brass Adapter 5 25 ea. Potable Water System Run No Lead Branch Run PEX Insert Tees - No Lead Brass 26000NL Series Solid no lead brass (C6900-ecobrass) PEX insert tees. SS press sleeves sold separately. Stk# Description Description (run run branch) Pkg Qty Carton Qty Unit List Price / Unit New! 26555NL 2" 2" 2" PEX No Lead Brass Tee ea. New! 26222NL 4" 4" 4" PEX No Lead Brass Tee ea. New! 26888NL " " " PEX No Lead Brass Tee 0 20 ea. 26NL - 4" - 4" - 4" PEX No Lead Brass Tee 5 80 ea NL - 2" - 2" - 2" PEX No Lead Brass Tee 5 0 ea. New! 26666NL 2" 2" 2" PEX No Lead Brass Tee 5 25 ea. 4

137 Heat Link PEX Insert Tees No Lead Branch PEX Insert Reducing Tees - No Lead Brass 26000NL Series Solid no lead brass (C6900-ecobrass) PEX insert tees. SS press sleeves sold separately. Run Run Stk# Description Description (run run branch) Pkg Qty Carton Qty Unit List Price / Unit New! 26552NL 2" 2" 4" PEX No Lead Brass Tee ea. New! 26225NL 4" 4" 2" PEX No Lead Brass Tee ea. New! 26252NL 4" 2" 4" PEX No Lead Brass Tee ea. New! 26255NL 4" 2" 2" PEX No Lead Brass Tee ea. New! 26822NL " 4" 4" PEX No Lead Brass Tee 5 50 ea. New! 26885NL " " 2" PEX No Lead Brass Tee 5 50 ea. New! 26882NL " " 4" PEX No Lead Brass Tee 5 50 ea. 2622NL - 4" 4" 4" PEX No Lead Brass Tee 5 00 ea. New! 2682NL - 4" " 4" PEX No Lead Brass Tee 5 50 ea. 2688NL - 4" " " PEX No Lead Brass Tee 5 00 ea. Sept NL - 4" - 4" 2" PEX No Lead Brass Tee 5 ea. 262NL - 4" - 4" 4" PEX No Lead Brass Tee 5 80 ea. 268NL - 4" - 4" " PEX No Lead Brass Tee 5 80 ea NL - 2" 4" 4" PEX No Lead Brass Tee 5 60 ea. New! 2642NL - 2" - 4" 4" PEX No Lead Brass Tee 5 25 ea NL - 2" - 2" 4" PEX No Lead Brass Tee 5 50 ea. 2648NL - 2" - 4" " PEX No Lead Brass Tee 5 50 ea NL - 2" " " PEX No Lead Brass Tee 5 50 ea. 264NL - 2" - 4" - 4" PEX No Lead Brass Tee 5 40 ea NL - 2" - 2" " PEX No Lead Brass Tee 5 40 ea. 2644NL - 2" - 2" - 4" PEX No Lead Brass Tee 5 40 ea. New! 266NL 2" - 4" - 4" PEX No Lead Brass Tee 5 25 ea. New! 26642NL 2" - 2" 4" PEX No Lead Brass Tee 5 25 ea. New! 26648NL 2" - 2" " PEX No Lead Brass Tee 5 25 ea. New! 2664NL 2" - 2" - 4" PEX No Lead Brass Tee 5 25 ea. New! 26644NL 2" - 2" - 2" PEX No Lead Brass Tee 5 25 ea. New! 26662NL 2" 2" 4" PEX No Lead Brass Tee 5 25 ea. New! 26668NL 2" 2" " PEX No Lead Brass Tee 5 25 ea. New! 2666NL 2" 2" - 4" PEX No Lead Brass Tee 5 25 ea. New! 26664NL 2" 2" - 2" PEX No Lead Brass Tee 5 25 ea. Potable Water System 5

138 Heat Link PEX Insert Tees Branch PEX Insert Tees - HPP 6000 Series High Performance Polymer PEX insert tees. SS press sleeves sold separately. Run Run Stk# Description Description (run run branch) Pkg Qty Carton Qty Unit List Price / Unit " 2" 2" PEX HPP Tee ea " 4" 4" PEX HPP Tee ea " " " PEX HPP Tee 0 00 ea. Run Branch Run PEX Insert Reducing Tees - HPP 6000 Series High Performance Polymer PEX insert reducing tees. SS press sleeves sold separately. Potable Water System Stk# Description Description (run run branch) Pkg Qty Carton Qty Unit List Price / Unit " 2" 4" PEX HPP Tee ea " 4" 2" PEX HPP Tee ea " 4" " PEX HPP Tee 5 00 ea " 2" 2" PEX HPP Tee ea " 2" 4" PEX HPP Tee ea " " 2" PEX HPP Tee 0 60 ea " " 4" PEX HPP Tee 5 00 ea " 4" 4" PEX HPP Tee 5 20 ea " 4" " PEX HPP Tee 5 00 ea. 6

139 Heat Link PEX Insert Plugs No Lead PEX Insert Plugs - No Lead Brass 25000NL Series Solid no lead brass (C6900-ecobrass) PEX insert plug. SS press sleeves sold separately. New! 25005NL 2" PEX No Lead Brass Plug ea. New! 25022NL 4" PEX No Lead Brass Plug ea. New! 25028NL " PEX No Lead Brass Plug 5 50 ea. 2505NL - 4" PEX No Lead Brass Plug ea. 2504NL - 2" PEX No Lead Brass Plug 5 0 ea. New! 25054NL 2" PEX No Lead Brass Plug 5 50 ea. PEX Insert Plugs - HPP 5000 Series High Performance Polymer PEX insert plugs. SS press sleeves sold separately " PEX HPP Plug ea " PEX HPP Plug ea " PEX HPP Plug ea. Potable Water System 7

140 Heat Link Ball Valves No Lead Chrome Plated Straight Ball Valve - No Lead Brass Stk #2505NL No lead brass (C6900-ecobrass) 2" PEX 8" O.D. compression, plated straight ball valve. SS press sleeves sold separately. 2505NL 2" PEX 8" O.D. No Lead Brass Plated Straight Ball Valve ea. Chrome Plated Angle Ball Valve - No Lead Brass Stk# 2605NL No Lead No lead brass (C6900-ecobrass) 2" PEX 8" O.D. compression, plated angle ball valve. SS press sleeves sold separately. 2605NL 2" PEX 8" O.D. No Lead Brass Plated Angle Ball Valve ea. No Lead Straight Ball Valve - No Lead Brass Stk# 2905NL No lead brass (C6900-ecobrass) 2" PEX 4" O.D. compression, straight ball valve. SS press sleeves sold separately. New! 2905NL 2" PEX 4" O.D. No Lead Straight Ball Valve ea. Potable Water System No Lead PEX Barb Straight Ball Valves - No Lead Brass 2700NL Series No lead brass (C6900-ecobrass) valve. SS press sleeves sold separately. 2705NL 2" PEX Straight No Lead Brass Ball Valve ea. 2722NL 4" PEX Straight No Lead Brass Ball Valve ea. 8

141 Heat Link Ball Valves Stop and Waste Valves - No Lead Brass 2700NL Series No Lead No lead brass (C6900-ecobrass) stop and waste valves. SS press sleeves sold separately. New! 2775NL 2" PEX No Lead Stop and Waste Valve ea. New! 2772NL 4" PEX No Lead Stop and Waste Valve ea. No Lead 2" PEX 2" M/Sweat Straight Ball Valve - No Lead Brass Stk# 2405NL No lead brass (C6900-ecobrass) 2" PEX 2" male sweat ball valve. SS press sleeves sold separately. New! 2405NL 2" PEX 2" No Lead M/Sweat Straight Ball Valve ea. 4" PEX 4" MNPT Straight Ball Valve - No Lead Brass Stk# 2422NL No Lead No lead brass (C6900-ecobrass) 4" PEX 4" male NPT ball valve. SS press sleeves sold separately. New! 2422NL 4" PEX 4" MNPT No Lead Straight Ball Valve ea. Potable Water System 9

142 Heat Link Stubout Elbows 2" PEX Insert Closed, " 6" Stubout Elbow with Edge Bracket Stk# Copper stubout elbow allows for 90 transitions between fixtures and wall cavities. SS press sleeves sold separately " PEX Barb Stubout Elbow with Edge Bracket ea. 2" PEX Insert Closed, " 6" Stubout Elbow Stk# Copper stubout elbow allows for 90 transitions between fixtures and wall cavities. SS press sleeves sold separately " PEX Closed, - 2" 6" Stub-out Elbow 50 ea. 2" PEX Insert Male Sweat, " 4" Stubout Elbow Stk# 2824 Copper stubout elbow allows for 90 transitions between fixtures and wall cavities. SS press sleeves sold separately. Potable Water System " PEX M/Sweat, " 4" Stub-out Elbow 25 ea. 40

143 Heat Link Accessories J-Clips 2000 Series Fasten tubing to joists " J-Clip ea " J-Clip ea " J-Clip ea. Plastic Bend Support 8600 Series Allows for easy bending support and removal Plastic Bend Support for 8" and 2" Tubing ea Plastic Bend Support for 4" Tubing ea. Adjustable Angle Plastic Drop Ear Bend Support Stk# 8605 Allows for PEX tubing to stub out from a wall or floor. Support can be adjusted in 2.86 steps from straight to 90 bend Adjustable Angle Plastic Drop Ear Bend Support for 2" Tubing 50 ea. Metal Bend Support Series Allows for easy bending support and removal Metal Bend Support for 2" Tubing ea Metal Bend Support for 5 8" Tubing ea Metal Bend Support for 4" Tubing ea. Metal Drop Ear Bend Support Stk# Allows for easy bending support and removal of a PEX tubing stub out from a wall or floor. Tools & Parts Metal Drop Ear Bend Support for 2" Tubing ea. 4

144 Heat Link Tools HeatLink Strap-on Thermometer Stk# This surface mounted thermometer is used to measure surface temperatures of metallic piping. The Strap-on Thermometers can be mounted on pipe sizes ranging from 8" to - 2". Suggested applications: Use on stainless steel manifolds or supply and return piping to measure water temperatures. Range: 0-00 C, 2-22 F (dual scale) Strap-on Thermometer Pressure Test Kit Stk# 7995 Pressure test kit for use with heating manifolds. TwistSeal - replaces automatic air vent on cross tee for testing purposes. Stainless Steel - replaces hose bib for testing purposes. Kit includes two " plugs and 4 red rubber gaskets (2 are spares). For air tests with the TwistSeal Mini, use the red rubber gaskets; for hydrostatic tests use green fibre gaskets (included in manifold assembly kit) Pressure Test Kit Pressure Test Kit with Valve Stk# Pressure test kit for use with heating manifolds. TwistSeal - replaces automatic air vent on cross tee for testing purposes. Stainless Steel - replaces hose bib for testing purposes. Kit includes two " plugs and 4 red rubber gaskets (2 are spares). For air tests with the TwistSeal Mini, use the red rubber gaskets; for hydrostatic tests use green fibre gaskets (included in manifold assembly kit). Tools & Parts Pressure Test Kit with Extra Valve to Zero Gauge 42

145 Heat Link Tools HeatLink Deluxe Staple Gun Stk# 020 Lightweight and easy to use manual staple gun. Use series staples to fasten up to 5 8 (or 20 mm O.D.) PEX tubing to polystyrene insulation. 020 HeatLink Deluxe Staple Gun Staples for Deluxe Staple Gun Series Staples for fastening up to 5 8" (or 20mm O.D.) PEX tubing to polystyrene insulation. For use with HeatLink Deluxe Staple Gun # " Staples for HeatLink Deluxe Staple Gun 20 box " Staples for HeatLink Deluxe Staple Gun box Staples for Stand-up Stapler Series Staples for fastening up to 2" (or 8mm O.D.) PEX tubing to polystyrene insulation. For use with Stand-up Stapler #0220 (discontinued) " (50mm) HeatLink Staples for Stand-up Stapler 6 box " (60mm) Staples for Stand-up Stapler 2 box Tools & Parts 4

146 Heat Link Tools HeatLink Basic PEX Tubing Dispenser Stk# 000 Uncoils 60 from the free swinging arm to avoid kinks and enable easy installation of coiled PEX tubing. Quick deployment made possible by a slide & clamp design. Comes with carrying/storage bag. 000 Basic PEX Tubing Dispenser w/ Carrying Bag PEX Tubing Cutters Stk# 000 Quick precision cutting on PEX tubing or non-metallic tubing. 000 HeatLink PEX Tubing Cutters 50 ea. Tools & Parts 44

147 Heat Link Tools EasyFit Nut Wrench Stk# 252 Wrench for use with EasyFit 2" and 4" nuts " and 4" EasyFit Wrench Multi-purpose Wrench Stk# Wrench for use with #2200 manifold module nut and valve base Multiwrench for Manifold Nut and Base Assembly Tool for TwistSeal Mini Multiport Valves Stk# 784 Tool used to remove and install TwistSeal Mini Multiport valve cartridges. 784 Assembly tool for TwistSeal Mini Multiport Valves Non-Toxic Silicone O-Ring Lubricant Stk# 7995 & Lubrication for the manifold o-rings. Non-toxic silicone grease. Highly recommended for trouble free installation of manifold components g Bottle Non-toxic Silicone O-ring Lubricant g Bottle Non-toxic Silicone O-ring Lubricant Tools & Parts 45

148 Heat Link Tools Press Tool for Stainless Steel Sleeves 00 Series 05 Designed to create a watertight seal, the Press Sleeve Tool has a toggle action handle. Easy to load and simple to press, the pressed stainless steel sleeve provides a finished appearance on the transition from the end of the PEX to the insert fitting " Standard Press Tool for SS Sleeve 22 4" Standard Press Tool for SS Sleeve 25 2" & 4" Combo Standard Press Tool for SS Sleeve 28 " Standard Press Tool for SS Sleeve 5-4" Standard Press Tool for SS Sleeve 4-2" Standard Press Tool for SS Sleeve Angle Press Tool for Stainless Steel Sleeves 400 Series Designed to create a watertight seal in tight spaces, the Angle Press Sleeve Tool s head at a 90 angle to the toggle action handle. Easy to load and simple to press, the pressed stainless steel sleeve provides a finished appearance on the transition from the end of the PEX to the insert fitting " Angled Press Tool for SS Sleeve (for tight spaces) 422 4" Angled Press Tool for SS Sleeve (for tight spaces) Tools & Parts 46

149 Heat Link Tools Confined Space Press Tool for Stainless Steel Sleeves Stk# 40 Series The new Confined Space Press Tool is designed for one or two handed pressing and its unique design and expanded utility showcase HeatLink s focus on listening to the needs of customers and developing effective solutions for challenging situations. The Confined Space Tool is perfect for use in tight spaces where HPP Multiport Tees are used. It incorporates a W press profile for visual identification of an effective press and the handles can be opened in narrow spaces. The new tool is also smaller and lighter than the 00 series press tools. New! 4 2" Confined Space Press Tool 20 ea. New! 44 4" Confined Space Press Tool 20 ea. Confined Space Press Tool for Stainless Steel Sleeves Stk# 45 The Confined Space Press Tool comes with interchangeable collars for 2", 4" and " PEX tubing. Adjustable lever allows for easier pressing with multiple squeezes. Comes with storage case. Dec in- Confined Space Press Tool with Case Tools & Parts * Check with your local representative for availability. 47

150 Heat Link Tools Slim-line Power Press Tool Stk# 500 The Slim-line Power Press Tool is a battery powered hydraulic pressing tool for up to - 2" SS press sleeves. Comes with one 8V.Ah Li-ion battery, battery charger, and hard plastic case. Jaws for the Power Press Tool are sold separately. New! 500 Slim-line Power Press Tool Jaws for Slim-line Power Press Tool 500 Series Jaws for use with the Slim-line Power Press Tool (#500). Compatible with the following third-party tools: Nibco PC-20M Mini Nibco PC-0M Mini Rothenberger Compact May be compatible with other third-party tools, please contact your local representative to confirm. New! 505 2" Jaws for Slim-line Power Press Tool New! 522 4" Jaws For Slim-line Power Press Tool New! 528 " Jaws for Slim-line Power Press Tool New! 55-4" Jaws for Slim-line Power Press Tool New! 54-2" Jaws for Slim-line Power Press Tool TBA* 554 2" Jaws for Slim-line Power Press Tool USB Diagnostic Tool for Power Press Tool Stk# 59 Test and monitor the quality of presses to verify and record for your customers a work-related proof of quality. The Slim-line Power Press Tool records performance parameters such as the number of presses, and current consumption in Ah or hours of operation. The USB Diagnostic Tool along with the software, can transmit this data to a computer where it can be organized and printed in an easy to analyze form. User errors such as an early stoppage and retract of the hydraulic system or other sources of defect which may prevent a correct press will be indicated. Tools & Parts New! 59 USB Diagnostic Tool for Power Press Tool 48 * Check with your local representative for availability.

151 Heat Link Tools Jaws for Power Press Tool with Pistol Grip 600 Series Jaws compatible with the following third-party tools: Nibco PC-280 Nibco PC-00 Ridgid 20-E Ridgid RP0-B Ridgid CT400 Ridgid RP0-C Ridgid RP40 May be compatible with other third-party tools, please contact your local representative to confirm. New!* 605 2" Jaws for Power Press Tool with Pistol Grip New!* 622 4" Jaws for Power Press Tool with Pistol Grip New!* 628 " Jaws for Power Press Tool with Pistol Grip New!* 65-4" Jaws for Power Press Tool with Pistol Grip New!* 64-2" Jaws for Power Press Tool with Pistol Grip New!* 654 2" Jaws for Power Press Tool with Pistol Grip Tools & Parts * Check with your local representative for availability. 49

152 Heat Link Parts Stk# Description Pkg Qty CAD List Price TwistSeal (55mm) Manifold 7840 TwistSeal Deluxe (55mm) Zone Valve Supply Module (c/w o-ring) TwistSeal Deluxe (55mm) Balancing Return Module (c/w o-ring) 784 TwistSeal (55mm) Zone Valve Replacement Cartridge c/w O-ring 789 TwistSeal (55mm) Zone Valve Upgrade Assembly 7892 TwistSeal (55mm) Balance Valve Assembly O-ring for TwistSeal (55mm) Manifold Module 5 ea TwistSeal (55mm) Closed End Cap Self-sealing end piece which closes manifold " TwistSeal (55mm) Supply End Connection Self-sealing end-piece with " FNPT brass insert. (c/w o-ring) " TwistSeal (55mm) Supply End Connection Self-sealing end-piece with - 2" MNPT brass insert. (c/w o-ring) TwistSeal (55mm) Cross Tee TwistSeal Mini (40mm) Manifold 7820 TwistSeal Mini Deluxe (40mm) Zone Valve Supply Module The supply module (c/w o-ring) provides on/o manual control to allow isolation of individual loops. 782 TwistSeal Mini Deluxe (40mm) Balancing Return Module The return module (c/w o-ring) permits balancing of the ow rate. Tools & Parts 7822 TwistSeal Mini (40mm) Valveless Module The valveless module (c/w o-ring) can be eld equipped with shut-o assembly (#788) TwistSeal Mini (40mm) Zone Valve Replacement Cartridge c/w O-ring For TwistSeal Mini (40 mm) shut-o modules. 78 TwistSeal Mini Zone Valve Replacement Cartridge for Multiport Modules 50 * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line.

153 Heat Link Parts Stk# Description Pkg Qty CAD List Price 782 TwistSeal Mini Flow Meter Replacement Cartridge for 7800 Modules 788 TwistSeal Mini (40mm) Zone Valve Upgrade Assembly For TwistSeal Mini (40 mm) modules TwistSeal Mini (40mm) Balance Valve Assembly For TwistSeal Mini (40 mm) modules O-ring for TwistSeal Mini (40mm) & EasyFit 5 ea. Manifold Modules 7980 TwistSeal Mini (40mm) Closed End Cap Self-sealing end-piece which closes manifold TwistSeal Mini (40mm) Cross Tee c/w O-ring (c/w o-ring) 7985 " TwistSeal Mini (40mm) Union Cross Tee End Connection (c/w o-ring) Pair Thermometers for TwistSeal Mini Union Cross pair Tee End Connection 7995 Red Rubber Gasket for " Union End Connection pair (40mm) Air Tests Gasket for TwistSeal Mini (40mm) " Union Supply pair End Connection 2296 " MNPT Supply End Connection Self-sealing end-piece with " MNPT brass insert (c/w o-ring). TwistSeal (40 & 55mm) Manifold O-ring for PEX to TwistSeal Manifold Connecter 0 ea. For use with #77000 Series & #2000 Series Plastic Nut for TwistSeal Manifold Modules Plastic nut used to tighten pipe to manifold connectors to manifold Plastic Nut for TwistSeal Manifold Modules and 4" PEX Shut-o Cap TwistSeal - Red Tools & Parts * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line. 5

154 Heat Link Parts Stk# Description Pkg Qty CAD List Price TwistSeal Zone Actuator Base (40mm & 55mm) Balancing Valve Cap with Clip for TwistSeal Manifold 7892 O-ring for TwistSeal Valve Insert (40 & 55mm) 5 ea O-ring for TwistSeal Balancing Shaft - 6 2mm 5 ea. (Cone Side) 799 2" Cross Tee Plug For use with Cross Tee, comes complete with o-ring Metal Hose Bib System can easily be charged at manifold location. For use with the Cross Tee. 799 Manual Air Vent Used for manually removing air from system. For use with the Cross Tee Metal Automatic Air Vent Automatically removes air from system. For use with Cross Tee. 799 Manual Air Vent Key - 5mm Square, Blue Opens the manual air vent (#799) Plastic Hose Bib System can easily be charged at manifold location. For use with the Cross Tee Plastic Automatic Air Vent Automatically removes air from system. For use with Cross Tee Pair Thermometers c/w Well for TwistSeal pair Manifolds O-ring for 2" Cross Tee Accessories 5 ea. Tools & Parts EasyFit Manifold 22 Compression Stop Tee Valve Assembly c/w O-ring " EasyFit Nut 52 * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line.

155 Heat Link Parts Stk# Description Pkg Qty CAD List Price " EasyFit Nut - 4" Stainless Steel Manifold 760 Mounting Bracket for SS Manifold - New! 769 Hose Nozzle for SS Manifold 7692 " NPT Adapter for SS Manifold 769 Zone Valve Insert for - 4" SS Manifold (Return) 7692 Balancing Valve Insert for High Flow SS Manifold (Supply) 7696 Flow Meter Valve Insert (0-.5 USgpm Lock Nut) for - 4" SS Mfd (Sup.) Only compatible with #7698 Manifold Connecter Base Flow Meter Valve Insert (0-6 L/min) for - 4" SS Manifold (New Design) - New! 7698 Connecter Base for - 4" SS Manifold (Flow Meter w/lock Nut) Only compatible with #7696 Flow Meter with Lock Nut Connecter Base for - 4" SS Manifold Not compatible with #7696 Flow Meter with Lock Nut " Ball Valve Set for - 4" SS Manifold set O-ring for - 4" SS Manifold Coupling and End 0 ea. Connections Black Shut-o Cap for - 4" SS Manifold 7690 Hose Bib for - 4" SS Manifold 7696 Pressure Bypass for - 4" SS Manifold (requires 7705 & PEX) Tools & Parts * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line. 5

156 Heat Link Parts Stk# Description Pkg Qty CAD List Price 7779 O-ring for PEX to - 4" SS Manifold Connecter 0 ea. 2" Stainless Steel Manifold O-ring for 2" SS Manifold, Closed End, and Open End Adapters - New! OEM Manifold 7802 O-ring for Shut-o Valve Insert for 7800 Modules - 5 ea. Special Order** 78 Zone Valve Replacement Cartridge for 7800 Manifold - Special Order** 782 Balancing Valve Replacement Cartridge for 7800 Manifold - Special Order** Housings 790 Key Lock for Manifold Housing Door For 700, 7500, and 7600 series housings. Valves - 4-Way Mixing 5850 Mixing Valve Motor for - 2" and 2" Valves - While Supplies Last Valves 6286 Zone Valve Insert 2" (Blue Cap) 6296 Radiator Valve Insert 2" (Black Cap) Radiator Valve Insert 4" (Black Cap) Zone Valve Insert " (Black Cap) Tools & Parts 6290 Zone Valve Insert - 4" (Black Cap) and 4" (Blue Cap) 6480 " & - 4" 4-way Mixing Valve Repair Kit (v2 Valves) For and way mixing valves " & - 4" 4-way Mixing Valve Repair kit (v, Thermomix) 54 * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line.

157 Heat Link Parts Stk# Description Pkg Qty CAD List Price 649 Pressure Activated Bypass for Mixing Block " & 2" 4-way Cast Iron Mixing Valve Repair Kit For -way v and 4-way v mixing valves. Mixing Valve Motors Plastic Mixing Valve Motor Coupling for " - 2" 4- way Valves (Thermomix) AccessoryPack #5850 v2 Mounted on Black Cast Iron Mixing Valve 5890 Acc. Pack #580 v and 5850 v2 Mounted Brass Mixing Valve Accessory Pack for #5850 v (Rectangle, SM5) Actuators 5608 Zone Valve Ring for 5620 and 562 Actuator TwistSeal Manifold Actuator Ring - While Supplies Last 5609 Valve Actuator Ring Thermostats 458 A Time Delay (Slow Blow) 5 20mm Glass Fuse for 4600 Series Thermostats StatLink 4404 StatLink 5 Wire to Conventional Wire Adapter Sensors A Medium Lag (Med. Blow) 5 20mm Glass Fuse pair for While Supplies Last A Time Delay (Slow Blow) 5 20mm Glass Fuse pair for Outdoor Sensor (0K) Tools & Parts * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line. 55

158 Heat Link Parts Stk# Description Pkg Qty CAD List Price Tools 009 Dispenser Pin Set For Narrow PEX Coils - While set Supplies Last 0092 Dispenser Pin Set For Large PEX Coils - While set Supplies Last 48 E-Clips for Con ned Space Tools (2 per bag) - New! 49 Rebuild Kit for Con ned Space Tool - New! 90 Replacement Retaining Rings for Press Tools 902 Rebuild Kit for Straight 2" & 4" Press Tools 90 Rebuild Kit for ", - 4" Angle, Straight and Combo Press Tools Water Quality 029 O-Ring for the Side Stream Filter Mechanical Room in a Box WHTWSH4 4" Nitrile Washer for Panels 5 ea. NTRWSH " Nitrile Washer for Panels 5 ea. BRAADAF4MBS 4" MBSP " FNPT Adapter BRAADAMGF " MBSP " FNPT Adapter Tools & Parts BRAADA4SW BRAADA4MG4F Brass Adapter 4" " Swivel 4" MBSP 4" FNPT Adapter ACCCDP2 Accessory Pack for CDP200 Panel 56 * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line.

159 Heat Link Parts Stk# Description Pkg Qty CAD List Price ACCCDP2225 Accessory Pack for CDP220, CDP250, and CDP0 Panels ACCCDP2225M Accessory Pack for CDP220M/250M Panels ACCHEPSOL Accessory Pack for HEP and SOL Panels ACCSSLRG Accessory Pack for SSP and SST Panels with Large Pump ACCSSSML Accessory Pack for SSP and SST Panels with Small Pump ACCTMP04 Accessory Pack for TMP040 and WHP0 Panels ACCTMP07 Accessory Pack for TMP070 and TMP070Z Panels ACCTMPD Accessory Pack for TMP085 and TMP200DT Panels ACCTWH Accessory Pack for TWH Panels PWRBR2 Power Box for TMP040/070, SMP, ZMP, ELB and old SSP/SST PWRB4AR2 Power Box for TMP085DP, 200DT PWRB5R2 Power Box for TMP070Z, TWH070Z, TWH070XPZ PWRB6R2 Power Box for CDP Panels Compatible with Rev 2 (R2) CDP panels. PWRB7R2 PWRB7R2-WHP Power Box for HEP, TWH (except Z) Compatible with FLWSWTCH. Not compatible with HEPPS. Power Box for WHP Panels Compatible with FLWSWTCH. Not compatible with HEPPS. Tools & Parts PWRB2TH Power Box 2-Terminal Header 5 ea. * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line. 57

160 Heat Link Parts Stk# Description Pkg Qty CAD List Price PWRBTH Power Box -Terminal Header 5 ea. PLINTR20VA 24Vac 20VA Plug-In Transformer for Panels For CDP panels. PLINTR40VA 24Vac 40VA Plug-in Transformer for Panels For TMP070Z panel. CDPACT CDP Actuator for Distribution Header ECL02 ECL 02 Control 24V for SMP Panels ESM0 ESM -0 Outdoor & Room Sensor for Snow Melt Panels ESM ESM- Supply Sensor for SMP Panels HTEX Plate Heat Exchanger For HEP025 panel. HTEX Plate Heat Exchanger For SOL080, SMP05, SMP250, SMP5 and panels. HTEX Plate Heat Exchanger For HEP080, HEP095, and SMP425 panels. BRAVLVG-WMX " -way Rotary Valve Body DN20 G " Connection "G" Thread For CDP0 panels. BRAVLV2-0MRUN 4" -way Thermostatic Mixing Valve For TMP040 panel. PG4NPT2560 Economy Pressure Guage 0-60psi/kPa - 2-2" Dial 4" NPT Bottom For SMP and PSP panels. Tools & Parts PG4NPT260 CHVLV20 Pressure Gauge for HEP and SOL Panels Check Valve for UPS5-58 Pump PUMP558 UPS5-58RU Composite 5V Pump 58 * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line.

161 Heat Link Parts Stk# Description Pkg Qty CAD List Price PUMP2699 UPS26-99FC 5V Cast Iron Pump PUMP2699BR UPS26-99BFC 5V Bronze Pump ELBP Panels AHP5500W240ELE AHS 5500W-240V Element for ELBP - New! AHPAHSDPCB40F AHS PCB Board - 40F for ELBP - New! AHPAHSFLOWSENSOR AHS - Flow Sensor for ELBP - New! AHPAHSINLETSCREEN AHS - Inlet Screen for ELBP - New! AHPAHSINLETTESEN AHS Inlet Temp Sensor for ELBP - New! AHPAHSOUTLETTESEN AHS Outlet Temp Sensor for ELBP - New! AHPAHSRELAYFUSE AHS Relay Fuse for ELBP - New! AHPAHSTRIACLG AHS Triac Set - Large for ELBP - New! AHPAHSTRIACME AHS Triac Set - Medium for ELBP - New! SMP Panels DRVWSNS Driveway Sensor for Copper SMP Panels Tools & Parts * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line. 59

162 Heat Link Listing by Stk# Stk# Description Status List Price / Unit Pg HeatLink Preventative Maintenance Water Analysis (requires wsb2) Molybdenum Test Kit L Corrosion Inhibitor (Molybdate Based) 56 0 L Purging Compound (Pre & Post Operational Cleaner) L Postoperational Filtration Cleaner " Side Stream Filter O-Ring for the Side Stream Filter Deluxe PEX Tubing Dispenser Discontinued 000 Basic PEX Tubing Dispenser w/ Carrying Bag Dispenser Pin Set For Narrow PEX Coils WSL Dispenser Pin Set For Large PEX Coils WSL HeatLink PEX Tubing Cutters HeatLink Deluxe Staple Gun " and 4" EasyFit Wrench " Standard Press Tool for SS Sleeve " Standard Press Tool for SS Sleeve " & 4" Combo Standard Press Tool for SS Sleeve " Standard Press Tool for SS Sleeve " Standard Press Tool for SS Sleeve " Standard Press Tool for SS Sleeve " Angled Press Tool for SS Sleeve (for tight spaces) " Angled Press Tool for SS Sleeve (for tight spaces) " Confined Space Press Tool New! " Confined Space Press Tool New! in- Confined Space Press Tool with Case New!* E-Clips for Confined Space Tools (2 per bag) New! Rebuild Kit for Confined Space Tool New! Slim-line Power Press Tool New! " Jaws for Slim-line Power Press Tool New! " Jaws For Slim-line Power Press Tool New! " Jaws for Slim-line Power Press Tool New! " Jaws for Slim-line Power Press Tool New! " Jaws for Slim-line Power Press Tool New! " Jaws for Slim-line Power Press Tool TBA* USB Diagnostic Tool for Power Press Tool New! " Jaws for Power Press Tool with Pistol Grip New!* " Jaws for Power Press Tool with Pistol Grip New!* " Jaws for Power Press Tool with Pistol Grip New!* " Jaws for Power Press Tool with Pistol Grip New!* " Jaws for Power Press Tool with Pistol Grip New!* " Jaws for Power Press Tool with Pistol Grip New!* 49 Stk# Description Status List Price / Unit Pg. 90 Replacement Retaining Rings for Press Tools Rebuild Kit for Straight 2" & 4" Press Tools Rebuild Kit for ", - 4" Angle, Straight and Combo Press Tools " J-Clip " J-Clip " J-Clip 4 20 Port Single Row, 4" PEX Closed End HPP Multiport Tee Port Single Row, 4" PEX Closed End HPP Multiport Tee Port Single Row, 4" PEX Closed End HPP Multiport Tee Port Single Row, 4" PEX Closed End HPP Multiport Tee Port Single Row, " PEX Closed End HPP Multiport Tee Port Single Row, " PEX Closed End HPP Multiport Tee Port Opposing Rows, " PEX Closed End HPP Multiport Tee Port Opposing Rows, " PEX Closed End HPP Multiport Tee Port Single Row, 4" PEX 4" PEX Flow Through HPP Multiport Tee Port Single Row, 4" PEX 4" PEX Flow Through HPP Multiport Tee Port Opposing Rows, 4" PEX 4" PEX Flow Through HPP Multiport Tee Port Opposing Rows, 4" PEX 4" PEX Flow Through HPP Multiport Tee Port Single Row, " PEX 4" PEX Flow Through HPP Multiport Tee Port Single Row, " PEX 4" PEX Flow Through HPP Multiport Tee Port Single Row, " PEX 4" PEX Flow Through HPP Multiport Tee Port Single Row, " PEX 4" PEX Flow Through HPP Multiport Tee Port Opposing Rows, " PEX 4" PEX Flow Through HPP Multiport Tee Port Opposing Rows, " PEX 4" PEX Flow Through HPP Multiport Tee " PEX HPP Plug " PEX HPP Plug " PEX HPP Plug " 4" 4" PEX HPP Tee " 4" 2" PEX HPP Tee " 4" " PEX HPP Tee 6 * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line. 60

163 Heat Link Listing by Stk# Stk# Description Status List Price / Unit Pg " 2" 4" PEX HPP Tee " 2" 2" PEX HPP Tee " 2" 4" PEX HPP Tee " 2" 2" PEX HPP Tee " 4" 4" PEX HPP Tee " 4" " PEX HPP Tee " " 4" PEX HPP Tee " " 2" PEX HPP Tee " " " PEX HPP Tee " PEX 2" MNPT HPP Adapter " PEX 4" MNPT HPP Adapter " PEX 2" MNPT HPP Adapter " PEX 4" MNPT HPP Adapter " PEX Ballcock/Closet FNPT Swivel HPP Adapter " PEX 4" FNPT Swivel HPP Adapter " PEX 2" FNPT Swivel HPP Adapter " 2" PEX HPP Elbow " 4" PEX HPP Elbow " " PEX HPP Elbow " 2" PEX HPP Elbow " PEX 2" MNPT HPP Elbow " PEX 8" MNPT HPP Dishwasher Elbow " PEX 2" FNPT HPP Swivel Elbow " 2" PEX HPP Coupling " 4" PEX HPP Coupling " " PEX HPP Coupling " 2" PEX HPP Coupling " 4" PEX HPP Coupling " 00ft Blue PureLink Plus UV Stabilized PEX-a PexCube " 00ft Blue PureLink Plus UV Stabilized PEX-a PexCube " 00ft Blue PureLink Plus UV Stabilized PEX-a Tubing 7, " 00ft PureLink Plus UV Stabilized PEX-a Tubing " 00ft PureLink Plus UV Stabilized PEX-a Tubing " 00ft PureLink Plus UV Stabilized PEX-a Tubing New! " 20 20ft Blue PureLink Plus UV Stabilized PEX-a Tubing " 0 20ft Blue PureLink Plus UV Stabilized PEX-a Tubing " 5 20ft Blue PureLink Plus UV Stabilized PEX-a Tubing 7 Stk# Description Status List Price / Unit Pg " 5 20ft PureLink Plus UV Stabilized PEX-a Tubing " 5 20ft PureLink Plus UV Stabilized PEX-a Tubing " 5 20ft PureLink Plus UV Stabilized PEX-a Tubing New! " 00ft Blue PureLink Plus UV Stabilized PEX-a Tubing 7, " 00ft Blue PureLink Plus UV Stabilized PEX-a Tubing 7, " 00ft Blue PureLink Plus UV Stabilized PEX-a Tubing 7, " 00ft PureLink Plus UV Stabilized PEX-a Tubing " 00ft PureLink Plus UV Stabilized PEX-a Tubing " 00ft PureLink Plus UV Stabilized PEX-a Tubing New! " 25 2ft Blue PureLink Plus UV Stabilized PEX-a Tubing New! " 0 2ft Blue PureLink Plus UV Stabilized PEX-a Tubing New! " 5 2ft Blue PureLink Plus UV Stabilized PEX-a Tubing New! " 5 2ft PureLink Plus UV Stabilized PEX-a Tubing New! " 500ft Blue PureLink Plus UV Stabilized PEX-a Tubing 7, " 500ft Blue PureLink Plus UV Stabilized PEX-a Tubing 7, " 000ft Blue PureLink Plus UV Stabilized PEX-a Tubing 7, " 000ft Blue PureLink Plus UV Stabilized PEX-a Tubing 7, " 00ft Red PureLink Plus UV Stabilized PEX-a PexCube " 00ft Red PureLink Plus UV Stabilized PEX-a PexCube " 00ft Red PureLink Plus UV Stabilized PEX-a Tubing " 00ft Red PureLink Plus UV Stabilized PEX-a Tubing Discontinued; see " 00ft Red PureLink Plus UV Stabilized PEX-a Tubing Discontinued; see " 20 20ft Red PureLink Plus UV Stabilized PEX-a Tubing " 0 20ft Red PureLink Plus UV Stabilized PEX-a Tubing " 5 20ft Red PureLink Plus UV Stabilized PEX-a Tubing " 5 20ft Red PureLink Plus UV Stabilized PEX-a Tubing Discontinued; see 2025 * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line. 6

164 Heat Link Listing by Stk# Stk# Description Status List Price / Unit Pg " 5 20ft Red PureLink Plus UV Stabilized PEX-a Tubing Discontinued; see " 00ft Red PureLink Plus UV Stabilized PEX-a Tubing " 00ft Red PureLink Plus UV Stabilized PEX-a Tubing " 00ft Red PureLink Plus UV Stabilized PEX-a Tubing " 00ft Red PureLink Plus UV Stabilized PEX-a Tubing Discontinued; see " 00ft Red PureLink Plus UV Stabilized PEX-a Tubing Discontinued; see " 25 2ft Red PureLink Plus UV Stabilized PEX-a Tubing New! " 0 2ft Red PureLink Plus UV Stabilized PEX-a Tubing New! " 500ft Red PureLink Plus UV Stabilized PEX-a Tubing " 500ft Red PureLink Plus UV Stabilized PEX-a Tubing " 000ft Red PureLink Plus UV Stabilized PEX-a Tubing " 000ft Red PureLink Plus UV Stabilized PEX-a Tubing WSL Compression Stop Tee EasyFit 2-Port Tee EasyFit -Port Tee " EasyFit Nut " EasyFit Nut Compression Stop Tee Valve Assembly c/w O-ring EasyFit Single Mounting Bracket Red Shut-off Cap Blue Shut-off Cap " FNPT Supply End Connection Discontinued 229 2" EasyFit Supply End Connection " EasyFit Supply End Connection " EasyFit Run End Connection " MNPT Supply End Connection EasyFit Manifold Closed End Cap " PEX Branch, 4" PEX Spin Closed " Trunk Cu Man. Discontinued; see " PEX Branch, 4" PEX Spin Closed " Trunk Cu Man. Discontinued; see " PEX Branch, 4" PEX Spin Closed " Trunk Cu Man. Discontinued; see " PEX Branch, 4" PEX Spin Closed " Trunk Cu Man. Discontinued; see " PEX Branch, 4" PEX Spin Closed " Trunk Cu Man. Discontinued; see 208 Stk# Description Status List Price / Unit Pg " PEX Branch, 4" PEX Spin Closed " Trunk Cu Man. Discontinued; see " PEX Branch, 4" PEX Spin Closed " Trunk Cu Man. Discontinued " PEX Branch, 4" PEX Spin Closed " Trunk Cu Man. Discontinued " PEX Branch, 4" PEX 4" PEX " Trunk Cu Man. Discontinued; see " PEX Branch, 4" PEX 4" PEX " Trunk Cu Man. Discontinued; see " PEX Branch, 4" PEX 4" PEX " Trunk Cu Man. Discontinued; see " PEX Branch, 4" PEX 4" PEX " Trunk Cu Man. Discontinued; see " PEX Insert Manifold Connecter 4, " PEX Insert Manifold Connecter c/w Nut 4, " EasyFit Outlet Cap with O-ring " PEX 2" M/Sweat Straight Ball Valve Discontinued; see 2405NL 2405NL 2" PEX 2" No Lead M/Sweat Straight Ball Valve New! " PEX 4" MNPT Straight Ball Valve Discontinued; see 2422NL 2422NL 4" PEX 4" MNPT No Lead Straight Ball Valve New! " PEX 8" O.D. Plated Straight Ball Valve Discontinued; see 2505NL 2505NL 2" PEX 8" O.D. No Lead Brass Plated Straight Ball Valve " PEX 8" O.D. Plated Angle Ball Valve Discontinued; see 2605NL 2605NL 2" PEX 8" O.D. No Lead Brass Plated Angle Ball Valve " PEX Straight Ball Valve Discontinued; see 2705NL 2705NL 2" PEX Straight No Lead Brass Ball Valve " PEX Straight Ball Valve Discontinued; see 2722NL 2722NL 4" PEX Straight No Lead Brass Ball Valve " PEX Stop and Waste Valve Discontinued; see 2772NL 2772NL 4" PEX No Lead Stop and Waste Valve New! " PEX Stop and Waste Valve Discontinued; see 2775NL 2775NL 2" PEX No Lead Stop and Waste Valve New! " PEX 4" O.D. Straight Ball Valve Discontinued; see 2905NL 2905NL 2" PEX 4" O.D. No Lead Straight Ball Valve New! 8 * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line. 62

165 Heat Link Listing by Stk# Stk# Description Status List Price / Unit Pg " SS Press Sleeve " SS Press Sleeve " SS Press Sleeve " SS Press Sleeve " SS Press Sleeve " SS Press Sleeve New! " PEX Brass Plug Discontinued 25005NL 2" PEX No Lead Brass Plug New! " PEX Brass Plug Discontinued 25022NL 4" PEX No Lead Brass Plug New! " PEX Brass Plug Discontinued 25028NL " PEX No Lead Brass Plug New! NL - 4" PEX No Lead Brass Plug NL - 2" PEX No Lead Brass Plug NL 2" PEX No Lead Brass Plug New! " PEX 8" O.D. Adapter Discontinued; see 2575NL 2575NL 2" PEX 8" O.D. No Lead Brass Adapter New! " 4" 4" PEX Brass Tee Discontinued; see 26222NL 26222NL 4" 4" 4" PEX No Lead Brass Tee New! " 4" 2" PEX Brass Tee Discontinued; see 26225NL 26225NL 4" 4" 2" PEX No Lead Brass Tee New! " 2" 4" PEX Brass Tee Discontinued; see 26252NL 26252NL 4" 2" 4" PEX No Lead Brass Tee New! " 2" 2" PEX Brass Tee Discontinued; see 26255NL 26255NL 4" 2" 2" PEX No Lead Brass Tee New! NL - 4" 4" 4" PEX No Lead Brass Tee 5 262NL - 4" - 4" 4" PEX No Lead Brass Tee 5 26NL - 4" - 4" - 4" PEX No Lead Brass Tee 4 265NL - 4" - 4" 2" PEX No Lead Brass Tee Sept NL - 4" - 4" " PEX No Lead Brass Tee NL - 4" " 4" PEX No Lead Brass Tee New! NL - 4" " " PEX No Lead Brass Tee NL - 2" 4" 4" PEX No Lead Brass Tee NL - 2" - 4" 4" PEX No Lead Brass Tee New! 5 264NL - 2" - 4" - 4" PEX No Lead Brass Tee NL - 2" - 4" " PEX No Lead Brass Tee NL - 2" - 2" 4" PEX No Lead Brass Tee NL - 2" - 2" - 4" PEX No Lead Brass Tee NL - 2" - 2" - 2" PEX No Lead Brass Tee NL - 2" - 2" " PEX No Lead Brass Tee NL - 2" " " PEX No Lead Brass Tee 5 Stk# Description Status List Price / Unit Pg " 2" 4" PEX Brass Tee Discontinued; see 26552NL 26552NL 2" 2" 4" PEX No Lead Brass Tee New! " 2" 2" PEX Brass Tee Discontinued; see 26555NL 26555NL 2" 2" 2" PEX No Lead Brass Tee New! 4 266NL 2" - 4" - 4" PEX No Lead Brass Tee New! NL 2" - 2" 4" PEX No Lead Brass Tee New! NL 2" - 2" - 4" PEX No Lead Brass Tee New! NL 2" - 2" - 2" PEX No Lead Brass Tee New! NL 2" - 2" " PEX No Lead Brass Tee New! NL 2" 2" 4" PEX No Lead Brass Tee New! NL 2" 2" - 4" PEX No Lead Brass Tee New! NL 2" 2" - 2" PEX No Lead Brass Tee New! NL 2" 2" 2" PEX No Lead Brass Tee New! NL 2" 2" " PEX No Lead Brass Tee New! " 4" 4" PEX Brass Tee Discontinued; see 26822NL 26822NL " 4" 4" PEX No Lead Brass Tee New! " " 4" PEX Brass Tee Discontinued; see 26882NL 26882NL " " 4" PEX No Lead Brass Tee New! " " 2" PEX Brass Tee Discontinued; see 26885NL 26885NL " " 2" PEX No Lead Brass Tee New! " " " PEX Brass Tee Discontinued; see 26888NL 26888NL " " " PEX No Lead Brass Tee New! " PEX 2" M/Sweat Adapter Discontinued; see 2705NL 2705NL 2" PEX 2" M/Sweat No Lead Brass Adapter " PEX 4" M/Sweat Adapter Discontinued; see 2722NL 2722NL 4" PEX 4" M/Sweat No Lead Brass Adapter " PEX " M/Sweat Adapter ( 4" F/Sweat) Discontinued; see 2728NL 2728NL " PEX " M/Sweat No Lead Brass Adapter ( 4" F/Sweat) 4 275NL - 4" PEX - 4" M/Sweat No Lead Brass Adapter 4 274NL - 2" PEX - 2" M/Sweat No Lead Brass Adapter NL 2" PEX 2" M/Sweat No Lead Brass Adapter New! " PEX 2" F/Sweat Adapter Discontinued; see 27205NL 27205NL 2" PEX 2" F/Sweat No Lead Brass Adapter " PEX 4" F/Sweat Adapter Discontinued; see 27222NL * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line. 6

166 Heat Link Listing by Stk# Stk# Description Status List Price / Unit Pg NL 4" PEX 4" F/Sweat No Lead Brass Adapter " PEX " F/Sweat Adapter Discontinued; see 27228NL 27228NL " PEX " F/Sweat No Lead Brass Adapter NL - 4" PEX - 4" F/Sweat No Lead Brass Adapter " PEX " F/Sweat Adapter Discontinued; see 2728NL 2728NL 4" PEX " F/Sweat No Lead Adapter New! " PEX 2" MNPT Brass Adapter Discontinued; see 27505NL 27505NL 2" PEX 2" MNPT No Lead Brass Adapter New! " PEX 4" MNPT Brass Adapter Discontinued; see 27522NL 27522NL 4" PEX 4" MNPT No Lead Brass Adapter New! " PEX " MNPT Brass Adapter Discontinued; see 27528NL 27528NL " PEX " MNPT No Lead Brass Adapter 2755NL - 4" PEX - 4" MNPT No Lead Brass Adapter 2758NL - 4" PEX " MNPT No Lead Brass Adapter 2754NL - 2" PEX - 2" MNPT No Lead Brass Adaptor " PEX 4" MNPT Brass Adapter Discontinued; see 27552NL 27552NL 2" PEX 4" MNPT No Lead Brass Adapter New! 27554NL 2" PEX 2" MNPT No Lead Brass Adapter New! " PEX 4" MNPT Brass Adapter Discontinued; see 27582NL 27582NL " PEX 4" MNPT No Lead Brass Adapter " PEX 2" FNPT Brass Adapter Discontinued; see 27605NL 27605NL 2" PEX 2" FNPT No Lead Brass Adapter " PEX 4" FNPT Brass Adapter Discontinued; see 27622NL 27622NL 4" PEX 4" FNPT No Lead Brass Adapter " PEX " FNPT Brass Adapter Discontinued; see 27628NL 27628NL " PEX " FNPT No Lead Brass Adapter 2762NL - 4" PEX 4" FNPT No Lead Brass Adapter Sept NL - 4" PEX - 4" FNPT No Lead Brass Adapter 2768NL - 4" PEX " FNPT No Lead Brass Adapter Sept NL - 2" PEX - 2" FNPT No Lead Brass Adapter " PEX 4" FNPT Swivel Flexible 8" Water Heater Connection Discontinued " 2" PEX Brass Elbow Discontinued; see 28005NL 28005NL 2" 2" PEX No Lead Brass Elbow New! " 4" PEX Brass Elbow Discontinued; see 28022NL 28022NL 4" 4" PEX No Lead Brass Elbow New! 29 Stk# Description Status List Price / Unit Pg " " PEX Brass Elbow Discontinued; see 28028NL 28028NL " " PEX No Lead Brass Elbow New! NL - 4" - 4" PEX No Lead Brass Elbow NL - 2" - 2" PEX No Lead Brass Elbow NL 2" 2" PEX No Lead Brass Elbow New! " PEX Barb Stubout Elbow with Edge Bracket " PEX Closed, - 2" 6" Stub-out Elbow " 2" PEX Brass Elbow Discontinued; see 28225NL 28225NL 4" 2" PEX No Lead Brass Elbow New! " PEX M/Sweat, " 4" Stub-out Elbow " PEX 2" FNPT Drop Ear Brass Elbow Discontinued; see 2805NL 2805NL 2" PEX 2" FNPT Drop Ear No Lead Brass Elbow 282 2" PEX 8" FNPT Drop Ear Brass Elbow Discontinued; see 282NL 282NL 2" PEX 8" FNPT Drop Ear No Lead Brass Elbow 2855NL - 4" PEX - 4" MNPT No Lead Brass Elbow " PEX 8" MNPT Brass Dishwasher Elbow Discontinued 2858NL " PEX - 4" MNPT No Lead Brass Elbow " 2" PEX Brass Coupling Discontinued; see 29005NL 29005NL 2" 2" PEX No Lead Brass Coupling New! " 4" PEX Brass Coupling Discontinued; see 29022NL 29022NL 4" 4" PEX No Lead Brass Coupling New! " " PEX Brass Coupling Discontinued; see 29028NL 29028NL " " PEX No Lead Brass Coupling New! NL - 4" - 4" PEX No Lead Brass Coupling NL - 2" - 2" PEX No Lead Brass Coupling NL 2" 2" PEX No Lead Brass Coupling New! " 2" PEX Brass Coupling Discontinued; see 29225NL 29225NL 4" 2" PEX No Lead Brass Coupling New! NL - 4" " PEX No Lead Brass Coupling NL - 2" - 4" PEX No Lead Brass Coupling New! NL - 2" " PEX No Lead Brass Coupling NL 2" - 4" PEX No Lead Brass Coupling New! NL 2" - 2" PEX No Lead Brass Coupling New! " 4" PEX Brass Coupling Discontinued; see 29282NL 29282NL " 4" PEX No Lead Brass Coupling New! 28 * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line. 64

167 Heat Link Listing by Stk# Stk# Description Status List Price / Unit Pg Outdoor Sensor (0K) Universal Sensor (0K) Slab Sensor (0K) PVC Sleeve 20ft Cable Slab Sensor (0K) PVC Sleeve 40ft Cable Indoor Sensor (0K) Small Enclosure Indoor Sensor (0K) Flush Mount Slab Sensor (0K) SS Sleeve 0ft Cable Snow/Ice Sensor (0K) 65 ft cable 45, Snow/Ice Sensor Socket 45, Snow Melting Kit(Start/Stop Module w/slab and Universal Sensor) WSL 050 One Stage Setpoint Control HeatLink Compact Mixing Reset Control HeatLink Snow/Ice Detector & Melt Control StatLink 6 Zone Base Module StatLink 4 Zone Expansion Module StatLink 2 HD Zone Expansion Module StatLink 5 Wire to Conventional Wire Adapter StatLink Installation Track, 25" Vac DPDT Pump Relay Pin Round Socket for AC Relay HeatLink 24Vac DPDT Pump Relay Box A Time Delay (Slow Blow) 5 20mm Glass Fuse for 4600 Series Thermostats A Medium Lag (Med. Blow) 5 20mm Glass Fuse for 4090 WSL A Time Delay (Slow Blow) 5 20mm Glass Fuse for HeatLink Electronic Thermostat with LED and Setback Selector Switch HeatLink Digital Thermostat with Optional Floor Warming Discontinued; see HeatLink Digital Thermostat "new design" HeatLink Digital Timer Thermostat HeatLink Digital Heat/Cool Timer Thermostat Zone Valve Ring for 5620 and 562 Actuator TwistSeal Manifold Actuator Ring WSL Valve Actuator Ring HeatLink DDC Actuator for Manifolds and Valves HeatLink TwistSeal Manifold Actuator with LED HeatLink Valve & SS Manifold Actuator with LED HeatLink Multiport Manifold Actuator with LED 7 Stk# Description Status List Price / Unit Pg HeatLink TwistSeal Manifold Actuator c/w End Switch HeatLink Valve & SS Manifold Actuator c/w End Switch HeatLink Multiport Manifold Actuator c/w End Switch Thermostatic Head (6-28 C) Thermostatic Head c/w Capillary (86-49 F) Plastic Mixing Valve Motor Coupling for " - 2" 4-way Valves (Thermomix) Mixing Valve Motor for " and - 4" Valves WSL 5 58 Mixing Valve Motor for " to 2" FNPT Valves -Point Floating New! Mixing Valve Motor for " to 2" FNPT Valves DDC New! Mixing Valve Motor for - 2" and 2" Valves WSL Mixing Valve Motor for 2-2" to 4" Flange Mixing Valves WSL Mixing Valve Motor for 2" to 4" Flange Mixing Valves -Point Floating New! Mixing Valve Motor for 2" to 4" Flange Mixing Valves DDC New! AccessoryPack #5850 v2 Mounted on Black Cast Iron Mixing Valve Acc. Pack #580 v and 5850 v2 Mounted Brass Mixing Valve Accessory Pack for #5850 v (Rectangle, SM5) Pressure Activated Bypass Valve 4" Pressure Activated Bypass Valves " Pressure Activated Bypass Valves - 4" Straight Return Connecter 2" Angle Return Connecter 2" 6206 Straight Zone Valve 2" NPT Straight Zone Valve 4" NPT Straight Zone Valve " NPT 6200 Straight Zone Valve - 4" NPT Angle Radiator Valve 2", Nickel Plated Angle Radiator Valve 4", Nickel Plated Straight Radiator Valve 2", Nickel Plated Straight Radiator Valve 4", Nickel Plated Straight Balancing Valve " F/Sweat 6286 Zone Valve Insert 2" (Blue Cap) Radiator Valve Insert 2" (Black Cap) Radiator Valve Insert 4" (Black Cap) Zone Valve Insert " (Black Cap) Zone Valve Insert - 4" (Black Cap) and 4" (Blue Cap) 54 * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line. 65

168 Heat Link Listing by Stk# Stk# Description Status List Price / Unit Pg " -way Mixing/Diverting Valve WSL 6026 " -way FNPT Mixing / Diverting Valve New! " -way FNPT Mixing / Diverting Valve New! " -way FNPT Mixing Valve Discontinued; see " -way FNPT Mixing / Diverting Valve New! " -way FNPT Mixing Valve Discontinued; see " -way FNPT Mixing / Diverting Valve New! " Compact -way Mixing Valve " Compact -way Mixing Valve 6725 " Compact -way Mixing Valve 672-4" Compact -way Mixing Valve " 4-way FNPT Mixing Valve Discontinued; see " 4-way FNPT Mixing Valve New! " 4-way FNPT Mixing Valve WSL; see " 4-way FNPT Mixing Valve New! " 4-way FNPT Mixing Valve Discontinued; see " 4-way FNPT Mixing Valve New! " 4-way FNPT Mixing Valve Discontinued; see " 4-way FNPT Mixing Valve New! " x 4-way Flange Mixing Valve New! " 4-way Flange Mixing Valve WSL " 4-way Flange Mixing Valve New! " 4-way Flange Mixing Valve WSL " x 4-way Flange Mixing Valve New! " 4-way Flange Mixing Valve Discontinued 0 64 " 4-way Mixing Block with Pressure Bypass and Pump Discontinued 6480 " & - 4" 4-way Mixing Valve Repair Kit (v2 Valves) " & - 4" 4-way Mixing Valve Repair kit (v, Thermomix) Pressure Activated Bypass for Mixing Block " & 2" 4-way Cast Iron Mixing Valve Repair Kit " x 4-way Flange Mixing Valve New! " PEX Comp. 2" M/Sweat Adapter " PEX Comp. 4" M/Sweat Adapter " PEX Comp. 4" M/Sweat Adapter " PEX Comp. 2" F/Sweat Adapter " PEX Comp. 4" F/Sweat Adapter " PEX Comp. 2" F/Sweat 90 Elbow 24 Stk# Description Status List Price / Unit Pg " PEX Comp. 4" F/Sweat 90 Elbow " PEX Comp. 4" Straight F/Sweat Adapter " PEX Comp. 4" F/Sweat 90 Elbow " PEX Comp. 2" MNPT Adapter " PEX Comp. 2" MNPT Adapter " PEX Comp. x 4" MNPT Adapter " PEX Comp. 4" MNPT Adapter " PEX Comp. " MNPT Adapter mm PEX Comp. - 4" MNPT Adapter WSL mm PEX Comp. - 4" MNPT Adapter WSL mm PEX Comp. 2" MNPT Adapter WSL mm PEX Comp. 2" MNPT Adapter WSL mm PEX Comp. " MNPT Adapter WSL mm PEX Comp. " MNPT Adapter WSL " 2" PEX Comp. Coupling " 8" PEX Comp. Coupling " 5 8" PEX Comp. Coupling " 4" PEX Comp. Coupling " " PEX Comp. Coupling Surface Mounted Manifold Housing 24" 0" 5-2" Special Pricing Surface Mounted Manifold Housing 0" 0" 5-2" Surface Mounted Manifold Housing 42" 0" 5-2" Recessed Manifold Housing 24" 2" - 7 8" Recessed Manifold Housing 0" 2" - 7 8" Recessed Manifold Housing 4-2" 2" - 7 8" Key Lock for Manifold Housing Door Key Lock for Housing Door Coupling for SS Manifold Mounting Bracket for SS Manifold New! Loop SS Manifold with Flow Meters Loop SS Manifold with Flow Meters Loop SS Manifold with Flow Meters Loop SS Manifold with Flow Meters Loop SS Manifold with Flow Meters Loop SS Manifold with Flow Meters Loop SS Manifold with Flow Meters Loop SS Manifold with Flow Meters Loop SS Manifold with Flow Meters 6 76 Loop SS Manifold with Flow Meters Loop SS Manifold with Flow Meters Hose Nozzle for SS Manifold 5 * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line. 66

169 Heat Link Listing by Stk# Stk# Description Status List Price / Unit Pg " NPT Adapter for SS Manifold Loop High Flow SS Manifold Loop High Flow SS Manifold Loop High Flow SS Manifold Loop High Flow SS Manifold Loop High Flow SS Manifold Loop High Flow SS Manifold Loop High Flow SS Manifold Loop High Flow SS Manifold Loop High Flow SS Manifold Loop High Flow SS Manifold Loop High Flow SS Manifold Coupling for 2" SS Manifold Loop 2" SS Manifold Loop 2" SS Manifold Loop 2" SS Manifold Loop 2" SS Manifold Loop 2" SS Manifold Loop 2" SS Manifold Loop 2" SS Manifold Loop 2" SS Manifold Loop 2" SS Manifold Loop 2" SS Manifold " Cap and Washer for 2" SS Manifold New! O-ring for 2" SS Manifold, Closed End, and Open End Adapters New! " PEX to 2" SS Manifold Connecter (single) Discontinued; see Closed End for 2" SS Manifold Discontinued; see 76840, " MNPT Open End Adapter for 2" SS Manifold Discontinued; see " MNPT Open End Adapter for 2" SS Manifold Discontinued; see " PEX to 2" SS Manifold Connecter (single) Discontinued; see " MNPT Assembly Kit for 2" SS Manifold New! " MNPT Assembly Kit for 2" SS Manifold New! " Plug for - 4" SS Manifold Flow Meter Valve Insert (0-6 L/min) Discontinued; see Zone Valve Insert for - 4" SS Manifold (Return) Balancing Valve Insert for High Flow SS Manifold (Supply) Flow Meter Valve Insert (0-.5 USgpm Lock Nut) for - 4" SS Mfd (Sup.) 5 Stk# Description Status List Price / Unit Pg Flow Meter Valve Insert (0-6 L/min) for - 4" SS Manifold (New Design) New! Connecter Base for - 4" SS Manifold (Flow Meter w/lock Nut) Connecter Base for - 4" SS Manifold " Ball Valve Set for - 4" SS Manifold O-ring for - 4" SS Manifold Coupling and End Connections Black Shut-off Cap for - 4" SS Manifold Hose Bib for - 4" SS Manifold Automatic Air Vent for - 4" SS Manifold Side Mount Automatic Air Vent Set for - 4" SS Manifold Pressure Bypass for - 4" SS Manifold (requires 7705 & PEX) Pressure Bypass Kit for - 4" SS Manifold Strap-on Thermometer " PEX to TwistSeal Manifold Connecter " PEX to TwistSeal Manifold Connecter " PEX to TwistSeal Manifold Connecter " PEX to TwistSeal Manifold Connecter c/w Nut Port Cap for - 4" SS Manifold " PEX to - 4" SS Manifold Connecter " PEX to - 4" SS Manifold Connecter " PEX to - 4" SS Manifold Connecter " PEX to 2" SS Manifold Connecter New! " PEX to 2" SS Manifold Connecter New! " PEX to 2" SS Manifold Connecter Special Order* O-ring for PEX to TwistSeal Manifold Connecter O-ring for PEX to - 4" SS Manifold Connecter O-ring for Shut-off Valve Insert for 7800 Modules Special Order* O-ring for #7800 Manifold Couplings and Brass Flanges Discontinued; see Zone Valve Replacement Cartridge for 7800 Manifold Special Order* Balancing Valve Replacement Cartridge for 7800 Manifold Special Order* TwistSeal Mini Deluxe (40mm) Z.V. Supply & Balancing Return Module Pair 7820 TwistSeal Mini Deluxe (40mm) Zone Valve Supply Module TwistSeal Mini Deluxe (40mm) Balancing Return Module TwistSeal Mini (40mm) Valveless Module 50 * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line. 67

170 Heat Link Listing by Stk# Stk# Description Status List Price / Unit Pg TwistSeal Mini (40mm) Zone Valve Replacement Cartridge c/w O-ring TwistSeal Mini (40mm) 2-port Z.V.Supply & Flow Meter Return Module Pair 780 TwistSeal Mini (40mm) -port Z.V.Supply & Flow Meter Return Module Pair 78 TwistSeal Mini Zone Valve Replacement Cartridge for Multiport Modules TwistSeal Mini Flow Meter Replacement Cartridge for 7800 Modules Assembly tool for TwistSeal Mini Multiport Valves TwistSeal Mini (40mm) 2-port Z.V.Supply & Flow Bal. Return Module Pair 782 TwistSeal Mini (40mm) -port Z.V.Supply & Flow Bal. Return Module Pair TwistSeal Deluxe (55mm) Z.V. Supply & Balancing Return Module Pair TwistSeal Deluxe (55mm) Zone Valve Supply Module TwistSeal Deluxe (55mm) Balancing Return Module TwistSeal (55mm) Zone Valve Replacement Cartridge c/w O-ring TwistSeal Mini (40mm) Zone Valve Upgrade Assembly TwistSeal Mini (40mm) Balance Valve Assembly Plastic Nut for TwistSeal Manifold Modules Gray Plastic Nut for TwistSeal Manifold Modules and 4" PEX Shut-off Cap TwistSeal - Red TwistSeal Zone Actuator Base (40mm & 55mm) Balancing Valve Cap with Clip for TwistSeal Manifold TwistSeal (55mm) Zone Valve Upgrade Assembly TwistSeal (55mm) Balance Valve Assembly O-ring for TwistSeal Valve Insert (40 & 55mm) O-ring for TwistSeal Balancing Shaft - 6 2mm (Cone Side) O-ring for TwistSeal Mini (40mm) & EasyFit Manifold Modules O-ring for TwistSeal (55mm) Manifold Module " TwistSeal Mini (40mm) Deluxe Manifold Assembly Kit " TwistSeal (55mm) Deluxe Manifold Assembly Kit " TwistSeal (55mm) Basic Manifold Assembly Kit 9 Stk# Description Status List Price / Unit Pg " TwistSeal (55mm) Commercial Manifold Assembly Kit TwistSeal Mini (40mm) Closed End Cap TwistSeal Mini (40mm) Cross Tee c/w O-ring " TwistSeal Mini (40mm) Union Cross Tee End Connection TwistSeal Multiport (40mm) Double Mounting Bracket TwistSeal (55mm) Closed End Cap " TwistSeal (55mm) Supply End Connection " TwistSeal (55mm) Supply End Connection TwistSeal (55mm) Cross Tee " Cross Tee Plug Multiwrench for Manifold Nut and Base Metal Hose Bib Manual Air Vent Metal Automatic Air Vent Manual Air Vent Key - 5mm Square, Blue Plastic Hose Bib Pressure Test Kit Plastic Automatic Air Vent Pair Thermometers c/w Well for TwistSeal Manifolds Pair Thermometers for TwistSeal Mini Union Cross Tee End Connection g Bottle Non-toxic Silicone O-ring Lubricant 24, g Bottle Non-toxic Silicone O-ring Lubricant 24, Red Rubber Gasket for " Union End Connection (40mm) Air Tests Gasket for TwistSeal Mini (40mm) " Union Supply End Connection O-ring for 2" Cross Tee Accessories Pressure Test Kit with Extra Valve to Zero Gauge TwistSeal (55mm) Mounting Bracket 0 80 HeatSeal 50mm Endcap (Dry) WSL 804 HeatSeal 6mm Endcap (Dry) WSL 805 HeatSeal 75mm Endcap (Dry) WSL 806 HeatSeal 90mm Endcap (Dry) WSL 807 HeatSeal 0mm Endcap (Dry) WSL 802 HeatSeal " Dual Endcap (Dry) WSL 8022 HeatSeal 40mm Dual Endcap (Dry) WSL 802 HeatSeal 50mm Dual Endcap (Dry) WSL * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line. 68

171 Heat Link Listing by Stk# Stk# Description Status List Price / Unit Pg HeatSeal 6mm Dual End Cap (Dry) WSL 8 HeatSeal 50mm Shrink Cap (Wet) WSL 84 HeatSeal 6mm Shrink Cap (Wet) WSL 85 HeatSeal 75mm Shrink Cap (Wet) WSL 86 HeatSeal 90mm Shrink Cap (Wet) WSL 87 HeatSeal 0mm Shrink Cap (Wet) WSL 82 HeatSeal " Dual Shrink Cap (Wet) WSL 822 HeatSeal 40mm Dual Shrink Cap (Wet) WSL 82 HeatSeal 50mm Dual Shrink Cap (Wet) WSL 824 HeatSeal 6mm Dual Shrink Cap (Wet) WSL HeatSeal Coupling Hard Shell - All Regular Sizes WSL HeatSeal Tee Shell - All Regular Sizes WSL ft Roll Expansion Stripping " Conduit 90's " Conduit 90's " Conduit 90's " Conduit 90's Plastic Bend Support for 8" and 2" Tubing 55, Plastic Bend Support for 4" Tubing 55, Metal Bend Support for 2" Tubing 55, Metal Bend Support for 5 8" Tubing 55, Metal Bend Support for 4" Tubing 55, Metal Drop Ear Bend Support for 2" Tubing Adjustable Angle Plastic Drop Ear Bend Support for 2" Tubing " Aluminum Heat Transfer Plate for DryAbove /DryBelow Systems EndBend for DryAbove System SpacerClip for DryAbove System Tubing Tracking Track Staples Tie Straps - 5.5" Tie Straps - 7.5" " (50mm) HeatLink Staples for Standup Stapler 54, " (60mm) Staples for Stand-up Stapler 54, " Staples for HeatLink Deluxe Staple Gun 54, " Staples for HeatLink Deluxe Staple Gun 54, bs 2" 00ft Blue PureLink Plus Pipe-in-Pipe 2 Stk# Description Status List Price / Unit Pg. 9205rs 2" 00ft Red PureLink Plus Pipe-in-Pipe bs 4" 00ft Blue PureLink Plus Pipe-in-Pipe rs 4" 00ft Red PureLink Plus Pipe-in-Pipe bs " 00ft Blue PureLink Plus Pipe-in-Pipe rs " 00ft Red PureLink Plus Pipe-in-Pipe bs 2" 00ft Blue PureLink Plus Pipe-in-Pipe rs 2" 00ft Red PureLink Plus Pipe-in-Pipe bs 4" 00ft Blue PureLink Plus Pipe-in-Pipe rs 4" 00ft Red PureLink Plus Pipe-in-Pipe " 000ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing " 000ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing " 000ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing " 00ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing " 00ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing " 00ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing " 250ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing " 225ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing Discontinued " 0 20ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing " 5 20ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing " 5 20ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing " 5 20ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing mm 50ft O2 Barrier HeatLink PEX-a Tubing WSL " 00ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing rs 2" 00' O2 Barrier HeatLink Pipe-in-Pipe Red Sheath New! " 00ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing " 00ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing " 00ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing rs 4" 00' O2 Barrier HeatLink Pipe-in-Pipe Red Sheath Special Order* " 00ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing 5 * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line. 69

172 Heat Link Listing by Stk# Stk# Description Status List Price / Unit Pg " 00ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing mm 00ft O2 Barrier HeatLink PEX-a Tubing WSL " 450ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing Discontinued " 500ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing " 500ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing " 500ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing " 500ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing " 00ft O2 Barrier HeatLink UV Stabilized PEX-a Tubing Special Order* mm HeatSeal Insulated PEX-a Tubing WSL mm HeatSeal Insulated PEX-a Tubing WSL mm HeatSeal Insulated PEX-a Tubing WSL mm HeatSeal Insulated PEX-a Tubing WSL mm HeatSeal Insulated PEX-a Tubing WSL 9702 " Dual HeatSeal Insulated PEX-a Tubing WSL mm Dual HeatSeal Insulated PEX-a Tubing WSL mm Dual HeatSeal Insulated PEX-a Tubing WSL mm Dual HeatSeal Insulated PEX-a Tubing WSL " 000ft Non-Barrier HeatLink UV Stabilized PEX-a Tubing Special Order* " 200ft Non-Barrier HeatLink UV Stabilized PEX-a Tubing WSL " 450ft Non-Barrier HeatLink UV Stabilized PEX-a Tubing Special Order* " 000ft Natural HeatLink UV Stabilized PEX-a Tubing Discontinued ACCCDP2 Accessory Pack for CDP200 Panel 56 ACCCDP2225 Accessory Pack for CDP220, CDP250, and CDP0 Panels 57 ACCCDP2225M Accessory Pack for CDP220M/250M Panels 57 ACCHEPSOL Accessory Pack for HEP and SOL Panels 57 ACCSSLRG Accessory Pack for SSP and SST Panels with Large Pump 57 ACCSSSML Accessory Pack for SSP and SST Panels with Small Pump 57 ACCTMP04 Accessory Pack for TMP040 and WHP0 Panels 57 ACCTMP07 Accessory Pack for TMP070 and TMP070Z Panels 57 ACCTMPD Accessory Pack for TMP085 and TMP200DT Panels 57 ACCTWH Accessory Pack for TWH Panels 57 Stk# Description Status List Price / Unit Pg. ACT24SW Actuator with End Switch for CDP Distribution Header Discontinued ACTMXVLV Actuator for -way Mixing Valve Rotary Body Discontinued; see 58 ACTMXVLV-ROT DDC Actuator for -Way Mixing Rotary Valve Body Discontinued; see 585 AHP5500W240ELE AHS 5500W-240V Element for ELBP New! 59 AHPAHSDPCB40F AHS PCB Board - 40F for ELBP New! 59 AHPAHSFLOWSENSOR AHS - Flow Sensor for ELBP New! 59 AHPAHSINLETSCREEN AHS - Inlet Screen for ELBP New! 59 AHPAHSINLETTESEN AHS Inlet Temp Sensor for ELBP New! 59 AHPAHSOUTLETTESEN AHS Outlet Temp Sensor for ELBP New! 59 AHPAHSRELAYFUSE AHS Relay Fuse for ELBP New! 59 AHPAHSTRIACLG AHS Triac Set - Large for ELBP New! 59 AHPAHSTRIACME AHS Triac Set - Medium for ELBP New! 59 BRAADAF4MBS 4" MBSP " FNPT Adapter 56 BRAADAMGF " MBSP " FNPT Adapter 56 BRAADA4SW Brass Adapter 4" " Swivel 56 BRAADA4MG4F 4" MBSP 4" FNPT Adapter 56 BRAVLV-WMXTH " -way Thermostatic Mixing Valve (White Cap) Discontinued BRAVLV2-0MRUN 4" -way Thermostatic Mixing Valve 58 BRAVLVG-WMX " -way Rotary Valve Body DN20 G " Connection "G" Thread 58 CAD0 CAD Boiler Panel New! 66 CAD02 CAD Boiler Panel High Capacity New! 66 CDP200 CDP 200MBH 2-Temp System Panel with Pumps Discontinued; see CDP200R2 CDP200R2 CDP 200MBH 2-Temp System Panel with Pumps Rev2 92 CDP220 CDP 220MBH 2-Temp Combi DHW System Panel with 4 Pumps Discontinued; see CDP220R2 CDP220P CDP 220MBH 2-Temp Combi DHW System Panel with Pumps Discontinued; see CDP200R2 CDP220R2 CDP 220MBH 2-Temp Combi DHW System Panel with 4 Pumps Rev2 Special Order* 94 CDP250 CDP 250MBH 2-Temp Combi DHW System Panel with 4 Pumps Discontinued; see CDP250R2 CDP250M CDP 250MBH 2-Temp Combi DHW System Panel with 4 Pumps & LT Header Discontinued; see CDP250R2 CDP250MP CDP 250MBH 2-Temp Combi DHW System Panel with Pumps & LT Header Discontinued; see CDP250PR2 CDP250P CDP 250MBH 2-Temp Combi DHW System Panel with Pumps Discontinued; see CDP250PR2 CDP250PR2 CDP 250MBH 2-Temp Combi DHW System Panel with Pumps Rev2 Special Order* 94 CDP250R2 CDP 250MBH 2-Temp Combi DHW System Panel with 4 Pumps Rev2 Special Order* 94 * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line. 70

173 Heat Link Listing by Stk# Stk# Description Status List Price / Unit Pg. CDP0RP CDP 0MBH 2-Temp Combi DHW with Pumps & Outdoor Reset Discontinued; see CDP0RPR2 CDP0RPR2 CDP 0MBH 2-Temp Combi DHW with Pumps & Outdoor Reset Rev2 Special Order* 96 CDP0RP4 CDP 0MBH 2-Temp Combi DHW with 4 Pumps & Outdoor Reset Discontinued; see CDP0RP4R2 CDP0RP4R2 CDP 0MBH 2-Temp Combi DHW with 4 Pumps & Outdoor Reset Rev2 Special Order* 96 CDPACT CDP Actuator for Distribution Header 58 CHVLV20 Check Valve for UPS5-58 Pump 58 Cut Custom Coil Cutting DRVWSNS Driveway Sensor for Copper SMP Panels 59 DRVWSNS-SS Driveway Sensor for SMP Panels 47, 6 ECL02 ECL 02 Control 24V for SMP Panels 58 ECOZNP ECO Boiler Panel New! 62 ECO2ZN4P ECO Boiler Panel High Capacity New! 62 ELBP0 Electric Boiler Panel 0,000BTU 68 ELBP0TS Electric Boiler Panel 0,000BTU with Loop Twist Seal Mini Multiport New! 70 ELBP0TS5 Electric Boiler Panel 0,000BTU with 5 Loop Twist Seal Mini Multiport 70 ELBP50 Electric Boiler Panel 50,000BTU New! 68 ELBP50TS7 Electric Boiler Panel 50,000BTU with 7 Loop Twist Seal Mini Multiport New! 70 ESM0 ESM -0 Outdoor & Room Sensor for Snow Melt Panels 58 ESM ESM- Supply Sensor for SMP Panels 58 ETF899ASNS Sensor NTC 2K New! 47 ETO2SMCNTR Snowmelt Control - DDC ( or 2-Zone Snowmelting Sensor Sold Separately) New! 47 FLWSWTCH Flow Switch for Domestic Hot Water Priority 82, 86, 88, 90 HEP025 HEP 25MBH Isolation Heat Exchanger Panel Discontinued; see HEP025P HEP025P HEP 25MBH Isolation Heat Exchanger Panel 86 HEP080 HEP 80MBH Isolation Heat Exchanger Panel Discontinued; see HEP080P HEP080P HEP 80MBH Isolation Heat Exchanger Panel 86 HEP095 HEP 95MBH Isolation Heat Exchanger Panel Discontinued; see HEP095P HEP095P HEP 95MBH Isolation Heat Exchanger Panel Special Order* 88 HEPPS Flow Indicator Assembly for Domestic Hot Water Priority Discontinued HTEX Plate Heat Exchanger 58 HTEX Plate Heat Exchanger 58 HTEX Plate Heat Exchanger 58 NTRWSH " Nitrile Washer for Panels 56 Stk# Description Status List Price / Unit Pg. PG4NPT2560 Economy Pressure Guage 0-60psi/kPa - 2-2" Dial 4" NPT Bottom 58 PG4NPT260 Pressure Gauge for HEP and SOL Panels 58 PLINTR20VA 24Vac 20VA Plug-In Transformer for Panels 58 PLINTR40VA 24Vac 40VA Plug-in Transformer for Panels 58 PUMP558 UPS5-58RU Composite 5V Pump 58 PUMP2699 UPS26-99FC 5V Cast Iron Pump 59 PUMP2699BR UPS26-99BFC 5V Bronze Pump 59 PWRBR Power Box for TMP040 and TMP070 Discontinued; see PWRBR2 PWRBR2 Power Box for TMP , SMP, ZMP, ELB and old SSP/SST 57 PWRB2R Power Box for SSP and SST Panels with Small (5-58) Pump Discontinued; see PWRBR2 PWRB2TH Power Box 2-Terminal Header 57 PWRBTH Power Box -Terminal Header 58 PWRB4AR-SOL Power Box for SOL Panels Discontinued; see PWRB4AR2 PWRB4AR-TMPD Power Box for TMPxxxDP & TMPxxxDT Panels Discontinued; see PWRB4AR2 PWRB4AR-TWH Power Box for TWH070 Discontinued; see PWRB4AR2 PWRB4AR2 Power Box for TMP085DP, 200DT 57 PWRB5R Power Box for TMP070Z Discontinued; see PWRB5R2 PWRB5R2 Power Box for TMP070Z, TWH070Z, TWH070XPZ 57 PWRB6R Power Box for CDP Panels Discontinued; see PWRB6R2 PWRB6R2 Power Box for CDP Panels 57 PWRB7AR Power Box for WHP0 Discontinued PWRB7R-HEP Power Box for HEP Panels Discontinued; see PWRB7R2 PWRB7R-TWH Power Box for TWH070PS and TWH070XPS Discontinued PWRB7R2 Power Box for HEP, TWH (except Z) 57 PWRB7R2-WHP Power Box for WHP Panels 57 PWRB8AR-PSP Power Box for PSP Panels Discontinued; see PWRBR2 PWRB8AR-SMP Power Box for SMP Panels Discontinued; see PWRBR2 PWRB8AR-ZMP Power Box for ZMP Panels Discontinued; see PWRBR2 PWRB8R Power Box for SSP & SST Panels with Large (26-99) Pump Discontinued; see PWRBR2 SMP75SS-HEX SMP 75MBH SS Snow Melt Panel 2 20 HEX (DRVWSNS-SS sold sep) Special Order* 0 SMP00SS-HEX SMP 00MBH SS Snow Melt Panel 2 0 HEX (DRVWSNS-SS sold sep) Special Order* 0 * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line. 7

174 Heat Link Listing by Stk# Stk# Description Status List Price / Unit Pg. SMP00SS-HEX-H SMP 65MBH SS Snow Melt Panel 0 HEX & HH Pump (DRVWSNS-SS sold sep) Special Order* 0 SMP667 Replace SMP Control With #667 Snow/Ice Detector & Melt Control Special Order* 6 SMP667-Cu Replace Copper SMP Control With #667 Snow/Ice Detector & Melt Control Discontinued SMP667-SS Replace SS SMP Control With #667 Snow/ Ice Detector & Melt Control Discontinued SMP5 SMP 5MBH Copper Snow Melt Panel 4 20 Plate HEX (DRVWSNS sold sep) Special Order* 4 SMP75SS SMP 00MBH SS Snow Melt Panel (No HEX; DRVWSNS-SS sold sep) Special Order* 08 SMP75SSH SMP 75MBH SS Snow Melt Panel with HH Pump (No HEX; DRVWSNS-SS sold sep) Special Order* 08 SMP400D SMP 400MBH Copper Snow Melt Panel (No HEX; DRVWSNS sold sep) Special Order* 2 SMP425 SMP 425MBH Copper Snow Melt Panel 4 0 Plate HEX (DRVWSNS sold sep) Special Order* 4 SOL080 SOL 80MBH Solar Heat Exchanger Panel Special Order* 98 SSAACT Actuators Mounted on Manifold and Wired to StatLink SSADDC Installed Accessory 562 DDC Actuator on Mixing Valve in SST Panel SSAMRC Installed HeatLink Compact Mixing Reset Control SSAMXM Installed Floating Action Mixing Valve Motor SSAMXMDDC Installed DDC Mixing Valve Motor on Mixing Valve in SSTL Panel SSAPB Installed Accessory Pressure Bypass for - 4" SS Manifold SSASL Installed Accessory StatLink Base Module SSASLEM Installed Accessory StatLink Expansion Module SSASLEMHD Installed Accessory StatLink Heavy Duty Expansion Module SSATH Installed Accessory Thermostatic Head on Mixing Valve in SST Panel SSATH2 Thermostatic Head Installed on Mixing Valve in SST Small Mixing Panels Discontinued; see SSATH SSM04R SSM Recessed 4 Loop - 4" SS Manifold Panel Special Order* 00 SSM06R SSM Recessed 6 Loop - 4" SS Manifold Panel Special Order* 00 SSM08R SSM Recessed 8 Loop - 4" SS Manifold Panel Special Order* 00 SSM0R SSM Recessed 0 Loop - 4" SS Manifold Panel Special Order* 00 SSPLR04B SSP Recessed 4 Loop - 4" SS Man. Large Pump Panel Bot. feed Special Order* 02 SSPLR04T SSP Recessed 4 Loop - 4" SS Man. Large Pump Panel Top feed Special Order* 02 SSPLR06B SSP Recessed 6 Loop - 4" SS Man. Large Pump Panel Bot. Feed Special Order* 02 SSPLR06T SSP Recessed 6 Loop - 4" SS Man. Large Pump Panel Top Feed Special Order* 02 Stk# Description Status List Price / Unit Pg. SSPLR08B SSP Recessed 8 Loop - 4" SS Man. Large Pump Panel Bot. Feed Special Order* 02 SSPLR08T SSP Recessed 8 Loop - 4" SS Man. Large Pump Panel Top Feed Special Order* 02 SSPLR0B SSP Recessed 0 Loop - 4" SS Man. Large Pump Panel Bot. Feed Special Order* 02 SSPLR0T SSP Recessed 0 Loop - 4" SS Man. Large Pump Panel Top Feed Special Order* 02 SSPLR2B SSP Recessed 2 Loop - 4" SS Man. Large Pump Panel Bot. Feed Special Order* 02 SSPLR2T SSP Recessed 2 Loop - 4" SS Man. Large Pump Panel Top Feed Special Order* 02 SSPLS04 SSP Surface Mount 4 Loop - 4" SS Manifold Large Pump Panel Discontinued; see SSPLS04B SSPLS04B SSP SURF MNT 4 Loop - 4" SS Man. Large Pump Panel Bot. Feed Special Order* 02 SSPLS04T SSP SURF MNT 4 Loop - 4" SS Man. Large Pump Panel Top Feed Special Order* 02 SSPLS06 SSP Surface Mount 6 Loop - 4" SS Manifold Large Pump Panel Discontinued; see SSPLS06B SSPLS06B SSP SURF MNT 6 Loop - 4" SS Man. Large Pump Panel Bot. Feed Special Order* 02 SSPLS06T SSP SURF MNT 6 Loop - 4" SS Man. Large Pump Panel Top Feed Special Order* 02 SSPLS08 SSP Surface Mount 8 Loop - 4" SS Manifold Large Pump Panel Discontinued; see SSPLS08B SSPLS08B SSP SURF MNT 8 Loop - 4" SS Man. Large Pump Panel Bot. Feed Special Order* 02 SSPLS08T SSP SURF MNT 8 Loop - 4" SS Man. Large Pump Panel Top Feed Special Order* 02 SSPLS0 SSP Surface Mount 0 Loop - 4" SS Manifold Large Pump Panel Discontinued; see SSPLS0B SSPLS0B SSP SURF MNT 0 Loop - 4" SS Man. Large Pump Panel Bot. Feed Special Order* 02 SSPLS0T SSP SURF MNT 0 Loop - 4" SS Man. Large Pump Panel Top Feed Special Order* 02 SSPLS2B SSP SURF MNT 2 Loop - 4" SS Man. Large Pump Panel Bot. Feed Special Order* 02 SSPLS2T SSP SURF MNT 2 Loop - 4" SS Man. Large Pump Panel Top Feed Special Order* 02 SSPLS204 SSP SURF MNT 4 Loop - 4" High Flow SS Man. Large Pump Panel Discontinued; see SSPLS204B SSPLS204B SSP SURF MNT 4 Loop - 4" High Flow SS Man. Large Pump Panel Bot. Feed Special Order* 02 SSPLS204T SSP SURF MNT 4 Loop - 4" High Flow SS Man. Large Pump Panel Top Feed Special Order* 02 SSPLS206 SSP SURF MNT 6 Loop - 4" High Flow SS Man. Large Pump Panel Discontinued; see SSPLS06B SSPLS206B SSP SURF MNT 6 Loop - 4" High Flow SS Man. Large Pump Panel Bot. Feed Special Order* 02 * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line. 72

175 Heat Link Listing by Stk# Stk# Description Status List Price / Unit Pg. SSPLS206T SSP SURF MNT 6 Loop - 4" High Flow SS Man. Large Pump Panel Top Feed Special Order* 02 SSPLS208 SSP SURF MNT 8 Loop - 4" High Flow SS Man. Large Pump Panel Discontinued; see SSPLS08B SSPLS208B SSP SURF MNT 8 Loop - 4" High Flow SS Man. Large Pump Panel Bot. Feed Special Order* 02 SSPLS208T SSP SURF MNT 8 Loop - 4" High Flow SS Man. Large Pump Panel Top Feed Special Order* 02 SSPLS20 SSP SURF MNT 0 Loop - 4" High Flow SS Man. Large Pump Panel Discontinued; see SSPLS0B SSPLS20B SSP SURF MNT 0 Loop - 4" High Flow SS Man. Large Pump Panel Bot. Feed Special Order* 02 SSPLS20T SSP SURF MNT 0 Loop - 4" High Flow SS Man. Large Pump Panel Top Feed Special Order* 02 SSPLS22B SSP SURF MNT 2 Loop - 4" High Flow SS Man. Large Pump Panel Bot. Feed Special Order* 02 SSPLS22T SSP SURF MNT 2 Loop - 4" High Flow SS Man. Large Pump Panel Top Feed Special Order* 02 SSPSR04 SSP Recessed 4 Loop - 4" SS Manifold Small Pump Panel Discontinued; see SSPSR04B SSPSR04B SSP Recessed 4 Loop - 4" SS Manifold Small Pump Panel Bot. Feed Special Order* 02 SSPSR04T SSP Recessed 4 Loop - 4" SS Manifold Small Pump Panel Top Feed Special Order* 02 SSPSR06 SSP Recessed 6 Loop - 4" SS Manifold Small Pump Panel Discontinued; see SSPSR06B SSPSR06B SSP Recessed 6 Loop - 4" SS Manifold Small Pump Panel Bot. Feed Special Order* 02 SSPSR06T SSP Recessed 6 Loop - 4" SS Manifold Small Pump Panel Top Feed Special Order* 02 SSPSR08 SSP Recessed 8 Loop - 4" SS Manifold Small Pump Panel Discontinued; see SSPSR08B SSPSR08B SSP Recessed 8 Loop - 4" SS Manifold Small Pump Panel Bot. Feed Special Order* 02 SSPSR08T SSP Recessed 8 Loop - 4" SS Manifold Small Pump Panel Top Feed Special Order* 02 SSPSR0 SSP Recessed 0 Loop - 4" SS Manifold Small Pump Panel Discontinued; see SSPSR0B SSPSR0B SSP Recessed 0 Loop - 4" SS Manifold Small Pump Panel Bot. Feed Special Order* 02 SSPSR0T SSP Recessed 0 Loop - 4" SS Manifold Small Pump Panel Top Feed Special Order* 02 SSPSR2B SSP Recessed 2 Loop - 4" SS Manifold Small Pump Panel Bot. Feed Special Order* 02 SSPSR2T SSP Recessed 2 Loop - 4" SS Manifold Small Pump Panel Top Feed Special Order* 02 SSPSS04 SSP Surface Mount 4 Loop - 4" SS Manifold Small Pump Panel Discontinued; see SSPSS04B SSPSS04B SSP SURF MNT 4 Loop - 4" SS Man. Small Pump Panel Bot. Feed Special Order* 02 SSPSS04T SSP SURF MNT 4 Loop - 4" SS Man. Small Pump Panel Top Feed Special Order* 02 Stk# Description Status List Price / Unit Pg. SSPSS06 SSP Surface Mount 6 Loop - 4" SS Manifold Small Pump Panel Discontinued; see SSPSS06B SSPSS06B SSP SURF MNT 6 Loop - 4" SS Man. Small Pump Panel Bot. Feed Special Order* 02 SSPSS06T SSP SURF MNT 6 Loop - 4" SS Man. Small Pump Panel Top Feed Special Order* 02 SSPSS08 SSP Surface Mount 8 Loop - 4" SS Manifold Small Pump Panel Discontinued; see SSPSS08B SSPSS08B SSP SURF MNT 8 Loop - 4" SS Man. Small Pump Panel Bot. Feed Special Order* 02 SSPSS08T SSP SURF MNT 8 Loop - 4" SS Man. Small Pump Panel Top Feed Special Order* 02 SSPSS0 SSP Surface Mount 0 Loop - 4" SS Manifold Small Pump Panel Discontinued; see SSPSS0B SSPSS0B SSP SURF MNT 0 Loop - 4" SS Man. Small Pump Panel Bot. Feed Special Order* 02 SSPSS0T SSP SURF MNT 0 Loop - 4" SS Man. Small Pump Panel Top Feed Special Order* 02 SSPSS2B SSP SURF MNT 2 Loop - 4" SS Man. Small Pump Panel Bot. Feed Special Order* 02 SSPSS2T SSP SURF MNT 2 Loop - 4" SS Man. Small Pump Panel Top Feed Special Order* 02 SSTLR04 SST Rec. 4 Loop - 4" SS Manifold Large Mixing Panel Discontinued; see SSTLR04B SSTLR04B SST Recessed 4 Loop - 4" SS Manifold Large Mixing Panel Bottom Feed Special Order* 06 SSTLR04T SST Recessed 4 Loop - 4" SS Manifold Large Mixing Panel Top Feed Special Order* 06 SSTLR06 SST Recessed 6 Loop - 4" SS Manifold Large Mixing Panel Discontinued; see SSTLR06B SSTLR06B SST Recessed 6 Loop - 4" SS Manifold Large Mixing Panel Bottom Feed Special Order* 06 SSTLR06T SST Recessed 6 Loop - 4" SS Manifold Large Mixing Panel Top Feed Special Order* 06 SSTLR08 SST Recessed 8 Loop - 4" SS Manifold Large Mixing Panel Discontinued; see SSTLR08B SSTLR08B SST Recessed 8 Loop - 4" SS Manifold Large Mixing Panel Bottom Feed Special Order* 06 SSTLR08T SST Recessed 8 Loop - 4" SS Manifold Large Mixing Panel Top Feed Special Order* 06 SSTLR0 SST Recessed 0 Loop - 4" SS Manifold Large Mixing Panel Discontinued; see SSTLR0B SSTLR0B SST Recessed 0 Loop - 4" SS Manifold Large Mixing Panel Bottom Feed Special Order* 06 SSTLR0T SST Recessed 0 Loop - 4" SS Manifold Large Mixing Panel Top Feed Special Order* 06 SSTLR2B SST Recessed 2 Loop - 4" SS Manifold Large Mixing Panel Bottom Feed Special Order* 06 SSTLR2T SST Recessed 2 Loop - 4" SS Manifold Large Mixing Panel Top Feed Special Order* 06 * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line. 7

176 Heat Link Listing by Stk# Stk# Description Status List Price / Unit Pg. SSTLS04 SST Surface Mount 4 Loop - 4" SS Manifold Large Mixing Panel Discontinued; see SSTLS04B SSTLS04B SST SURF MNT 4 Loop - 4" SS Man. Large Mixing Panel Bot. Feed Special Order* 06 SSTLS04T SST SURF MNT 4 Loop - 4" SS Man. Large Mixing Panel Top Feed Special Order* 06 SSTLS06 SST Surface Mount 6 Loop - 4" SS Manifold Large Mixing Panel Discontinued; see SSTLS06B SSTLS06B SST SURF MNT 6 Loop - 4" SS Man. Large Mixing Panel Bot. Feed Special Order* 06 SSTLS06T SST SURF MNT 6 Loop - 4" SS Man. Large Mixing Panel Top Feed Special Order* 06 SSTLS08 SST Surface Mount 8 Loop - 4" SS Manifold Large Mixing Panel Discontinued; see SSTLS08B SSTLS08B SST SURF MNT 8 Loop - 4" SS Man. Large Mixing Panel Bot. Feed Special Order* 06 SSTLS08T SST SURF MNT 8 Loop - 4" SS Man. Large Mixing Panel Top Feed Special Order* 06 SSTLS0 SST SURF Mount 0 Loop - 4" SS Manifold Large Mixing Panel Discontinued; see SSTLS0B SSTLS0B SST SURF MNT 0 Loop - 4" SS Man. Large Mixing Panel Bot. Feed Special Order* 06 SSTLS0T SST SURF MNT 0 Loop - 4" SS Man. Large Mixing Panel Top Feed Special Order* 06 SSTLS2 SST SURF Mount 2 Loop - 4" SS Manifold Large Mixing Panel Discontinued SSTLS2B SST SURF MNT 2 Loop - 4" SS Man. Large Mixing Panel Bot. Feed Special Order* 06 SSTLS2T SST SURF MNT 2 Loop - 4" SS Man. Large Mixing Panel Top Feed Special Order* 06 SSTLS204B SST SURF MNT 4 Loop - 4" High Flow SS Man. Large Pump Panel Bot. Feed Special Order* 06 SSTLS204T SST SURF MNT 4 Loop - 4" High Flow SS Man. Large Pump Panel Top Feed Special Order* 06 SSTLS206B SST SURF MNT 6 Loop - 4" High Flow SS Man. Large Pump Panel Bot. Feed Special Order* 06 SSTLS206T SST SURF MNT 6 Loop - 4" High Flow SS Man. Large Pump Panel Top Feed Special Order* 06 SSTLS208B SST SURF MNT 8 Loop - 4" High Flow SS Man. Large Pump Panel Bot. Feed Special Order* 06 SSTLS208T SST SURF MNT 8 Loop - 4" High Flow SS Man. Large Pump Panel Top Feed Special Order* 06 SSTLS20B SST SURF MNT 0 Loop - 4" High Flow SS Man. Large Pump Panel Bot. Feed Special Order* 06 SSTLS20T SST SURF MNT 0 Loop - 4" High Flow SS Man. Large Pump Panel Top Feed Special Order* 06 SSTLS22B SST SURF MNT 2 Loop - 4" High Flow SS Man. Large Pump Panel Bot. Feed Special Order* 06 SSTLS22T SST SURF MNT 2 Loop - 4" High Flow SS Man. Large Pump Panel Top Feed Special Order* 06 SSTSR04 SST Recessed 4 Loop - 4" SS Manifold Small Mixing Panel Discontinued; see SSTSR04B Stk# Description Status List Price / Unit Pg. SSTSR04B SST Recessed 4 Loop - 4" SS Manifold Small Mixing Panel Bottom Feed Special Order* 04 SSTSR04T SST Recessed 4 Loop - 4" SS Manifold Small Mixing Panel Top Feed Special Order* 04 SSTSR06 SST Recessed 6 Loop - 4" SS Manifold Small Mixing Panel Discontinued; see SSTSR06B SSTSR06B SST Recessed 6 Loop - 4" SS Manifold Small Mixing Panel Bottom Feed Special Order* 04 SSTSR06T SST Recessed 6 Loop - 4" SS Manifold Small Mixing Panel Top Feed Special Order* 04 SSTSR08 SST Recessed 8 Loop - 4" SS Manifold Small Mixing Panel Discontinued; see SSTSR08B SSTSR08B SST Recessed 8 Loop - 4" SS Manifold Small Mixing Panel Bottom Feed Special Order* 04 SSTSR08T SST Recessed 8 Loop - 4" SS Manifold Small Mixing Panel Top Feed Special Order* 04 SSTSR0 SST Recessed 0 Loop - 4" SS Manifold Small Mixing Panel Discontinued; see SSTSR0B SSTSR0B SST Recessed 0 Loop - 4" SS Manifold Small Mixing Panel Bottom Feed Special Order* 04 SSTSR0T SST Recessed 0 Loop - 4" SS Manifold Small Mixing Panel Top Feed Special Order* 04 SSTSR2B SST Recessed 2 Loop - 4" SS Manifold Small Mixing Panel Bottom Feed Special Order* 04 SSTSR2T SST Recessed 2 Loop - 4" SS Manifold Small Mixing Panel Top Feed Special Order* 04 SSTSS04 SST Surface Mount 4 Loop - 4" SS Manifold Small Mixing Panel Discontinued; see SSTSS04B SSTSS04B SST SURF MNT 4 Loop - 4" SS Man. Small Mixing Panel Bot. Feed Special Order* 04 SSTSS04T SST SURF MNT 4 Loop - 4" SS Man. Small Mixing Panel Top Feed Special Order* 04 SSTSS06 SST Surface Mount 6 Loop - 4" SS Manifold Small Mixing Panel Discontinued; see SSTSS06B SSTSS06B SST SURF MNT 6 Loop - 4" SS Man. Small Mixing Panel Bot. Feed Special Order* 04 SSTSS06T SST SURF MNT 6 Loop - 4" SS Man. Small Mixing Panel Top Feed Special Order* 04 SSTSS08 SST Surface Mount 8 Loop - 4" SS Manifold Small Mixing Panel Discontinued; see SSTSS08B SSTSS08B SST SURF MNT 8 Loop - 4" SS Man. Small Mixing Panel Bot. Feed Special Order* 04 SSTSS08T SST SURF MNT 8 Loop - 4" SS Man. Small Mixing Panel Top Feed Special Order* 04 SSTSS0 SST SURF Mount 0 Loop - 4" SS Manifold Small Mixing Panel Discontinued; see SSTSS0B SSTSS0B SST SURF MNT 0 Loop - 4" SS Man. Small Mixing Panel Bot. Feed Special Order* 04 SSTSS0T SST SURF MNT 0 Loop - 4" SS Man. Small Mixing Panel Top Feed Special Order* 04 * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line. 74

177 Heat Link Listing by Stk# Stk# Description Status List Price / Unit Pg. SSTSS2B SST SURF MNT 2 Loop - 4" SS Man. Small Mixing Panel Bot. Feed Special Order* 04 SSTSS2T SST SURF MNT 2 Loop - 4" SS Man. Small Mixing Panel Top Feed Special Order* 04 TMP040 TMP 40MBH -way Mixing Panel 72 TMP070 TMP 70MBH -way Mixing Panel 72 TMP070Z TMP 70MBH -way Mixing Panel with Zoning Special Order* 74 TMP085DP TMP 85MBH Dual Pump -way Mixing panel 76 TMP200DT TMP 200MBH 2-Temperature -way Mixing Panel 78 TSM04R TSM Recessed 4 Loop TwistSeal Mini Multiport Manifold Panel Discontinued TSM06R TSM Recessed 6 Loop TwistSeal Mini Multiport Manifold Panel Discontinued TSM08R TSM Recessed 8 Loop TwistSeal Mini Multiport Manifold Panel Discontinued TSM0R TSM Recessed 0 Loop TwistSeal Mini Multiport Manifold Panel Discontinued TWH070 TWH 70MBH Tankless Water Heater Mixing Panel 80 TWH070P TWH 70MBH Tankless Water Heater Mixing Panel (DHW Priority Opt) Special Order* 82 TWH070PS TWH 70MBH Tankless Water Heater Mixing Panel with DHW Priority Discontinued; see TWH070P TWH070XP TWH 70MBH HH Tankless Water Heater Mixing Panel (DHW Priority Opt) 82 TWH070XPS TWH 70MBH HH Tankless Water Heater Mixing Panel with DHW Priority Discontinued; see TWH070XP TWH070XPZ TWH 70MBH High Head Tankless Water Heater Mixing Panel with Zoning Special Order* 84 TWH070Z TWH 70MBH Tankless Water Heater Mixing Panel with Zoning Special Order* 84 V0 V00 Boiler Panel New! 64 V02 V00 Boiler Panel High Capacity New! 64 WHP0 WHP 0MBH Water Heater Pump Panel with DHW Priority Discontinued; see WHP0P WHP0P WHP 0MBH Water Heater Pump Panel (DHW Priority Optional) Special Order* 90 WHTWSH4 4" Nitrile Washer for Panels 56 wsb2 #2 Water Sample Bottle w/cap - General 57 ZMP006 ZMP 6 Branch Zone Mixing Panel Discontinued ZMP008 ZMP 8 Branch Zone Mixing Panel Discontinued ZMP00 ZMP 0 Branch Zone Mixing Panel Discontinued ZMP02 ZMP 2 Branch Zone Mixing Panel Discontinued ZMP04 ZMP 4 Branch Zone Mixing Panel Discontinued * Check with your local representative for availability. ** Lead time may vary. Call to confirm time line. 75

178 Heat Link Notes 76

179

180 Heat Link Toll Free Phone: Toll Free Fax: HeatLink, DryAbove, DryBelow, EasyFit, EndBend, HeatSeal, PexCube, PureLink, and SpacerClip are either registered trademarks or trademarks of HeatLink Group Inc. L820ca Printed in USA HeatLink Group Inc.

Heat Link MECHANICAL ROOM IN A BOX. SSP Series. SS Manifold Pump Panel Installation, Operation, and Maintenance Manual. L6SSPxx000x-BMS SSPLR106T

Heat Link MECHANICAL ROOM IN A BOX. SSP Series. SS Manifold Pump Panel Installation, Operation, and Maintenance Manual. L6SSPxx000x-BMS SSPLR106T Heat Link SSP Series SS Manifold Pump Panel Manual NEUTRAL GROUND LIVE CAUTION 115 VOLTS ONLY SSPLR106T GROUND LIVE NEUTRAL CAUTION 115 VOLTS ONLY 120 40 60 60 80 100 C F 200 0 180 20 40 140 160 80 100

More information

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne. ELECTRONIC FAUCETS INSTRUCTION MANUAL 100 Haul Road Wayne, NJ 07470 Toll Free: (800) 631-0442 customerservice@krowne.com krowne.com Model 16-196 1 3 2 4 6 5 7 1. 2. 3. 4. 5. 6. 7. Aerator Sensor with Cable

More information

Heat Link MECHANICAL ROOM IN A BOX. SSP Series SS Manifold Pump Panel Installation, Operation, and Maintenance Manual. L6SSPxx000x SSPLR106T SSPSS106B

Heat Link MECHANICAL ROOM IN A BOX. SSP Series SS Manifold Pump Panel Installation, Operation, and Maintenance Manual. L6SSPxx000x SSPLR106T SSPSS106B SSP Series SS Manifold Pump Panel Manual GROUND LIVE NEUTRAL CAUTION 5 VOLTS ONLY 0 80 00 00 C F 80 60 40 60 0 0 40 40 60 80 00 SSPLR06T GROUND LIVE NEUTRAL CAUTION 5 VOLTS ONLY 0 80 00 00 C F 80 60 40

More information

Zurn Hydronics Prices Effective 1/01/06

Zurn Hydronics Prices Effective 1/01/06 CURRENT MFG LIST Radiant Tubing / Manifolds / Tools Boxed Barrier Pex Tubing QUE/QHR2PC1000X 3/8" x 1000' Roll (Barrier) $1,085.45 QUE/QHR2PC500X 3/8" x 500' Roll (Barrier) $542.73 QUE/QHR4PC500X 3/4"

More information

HVAC No. MFG Part No. Description Size Price

HVAC No. MFG Part No. Description Size Price Circulator Isolation Flanges and Valves Webstone 113460 113462 113464 113466 390608 390564 Flanged Isolation Valves 110-251F 110-252F 110-253F 110-254F SF-075T SF-100T Freedom Flange, Cast Iron Freedom

More information

Potable Piping System

Potable Piping System Page, May 2006 Potable Piping System BOW SUPERPEX is designed with three distinct layers for ultimate protection. The middle layer provides chlorine resistance as well as UV light exposure resistance plus

More information

FLUID POWER ENERGY, INC. W229 N591 Foster Court Waukesha, WI THERMOSTATIC VALVES. Instruction and Application Guidelines

FLUID POWER ENERGY, INC. W229 N591 Foster Court Waukesha, WI THERMOSTATIC VALVES. Instruction and Application Guidelines THERMOSTATIC VALVES Instruction and Application Guidelines Your FPE Thermostatic Valve has been manufactured with extreme care and tested to insure that it had no detectable defects at the time it left

More information

Table of Contents. Installation, Operation, and Maintenance Manual ELBPxx

Table of Contents. Installation, Operation, and Maintenance Manual ELBPxx Series ELBP8/ELBP30 FUSE C 4Vac R NC NO 0 min 5 Delay Off Actuator GROUND NEUTRAL LIVE Reset R CAUTION 5 VOLTS ONLY 3 4 5 6 7 8 8 Zone Wired Module 4038 Dry Contacts Pump Boiler ELBP50 GROUND NEUTRAL Reset

More information

ECO1ZN3P, ECO2ZN4P ECO

ECO1ZN3P, ECO2ZN4P ECO WARNING HOT This product may have hot fluid circulating through it. DO NOT TOUCH! SOME UNION NUTS MAY BECOME LOOSE AND CONSEQUENTLY LEAK THROUGH TRANSPORTATION VIBRATION AND HANDLING. DO NOT OVERTIGHTEN

More information

ProRadiant Controls, Valves and Actuators

ProRadiant Controls, Valves and Actuators 214 Controls, Valves and Actuators Stock Controls, Valves and Actuators BASIC HEATING CONTROL Features: Modulating mixing valve control Supply temperature high limit Seasonal pump activation Boiler activation

More information

2018 Canadian Price List

2018 Canadian Price List 2018 Canadian Price List EC170 Series Electric Strike EC240 Series Electric Strike Prices effective February 5, 2018 2 Prices effective May 1, 2008 ASSA ABLOY, the global leader in door opening solutions

More information

RA15/6T & TB Conversion Valve

RA15/6T & TB Conversion Valve Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from

More information

A. ASHRAE Handbook HVAC Applications, Snow Melting and Freeze Protection

A. ASHRAE Handbook HVAC Applications, Snow Melting and Freeze Protection PAGE 238318-1 SECTION 238318 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification sections,

More information

ProRadiant Manifolds, Stations and Fittings

ProRadiant Manifolds, Stations and Fittings Manifolds, Stations and Fittgs 197 Staless Manifolds and Accessories # of Outlets STAINLESS MANIFOLD - SHUT-OFF / BALANCING / FLOW METERS These preassembled 1-1/4" diameter staless supply and return manifolds

More information

Table of Contents. Installation, Operation, and Maintenance Manual V100 Series

Table of Contents. Installation, Operation, and Maintenance Manual V100 Series V101 EXPANSION TANK CONNECTION WARRANTY ON PUMPS VOID IF RUN DRY! CHECK VALVES INSTALLED IN ALL PUMPS WARNING HOT This product may have hot fluid circulating through it. DO NOT TOUCH! V10 EXPANSION TANK

More information

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit January 2008 WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit Installation Operation Maintenance The units are designed for permanent up flow, counter flow, or horizontal left or right airflow

More information

Drain Cooler Water tempering device

Drain Cooler Water tempering device Water tempering device Installation instructions & user manual READ AND SAVE THESE INSTRUCTIONS DC-EN/151214 Foreword Foreword 1. These installation instructions and operation manual have been developed

More information

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations Series 600 LFI / CFI Series 700 HFS Zone Control Stations Heating and Radiant Floor Zone Control Stations Installation Instructions Thank you for purchasing the finest in heating and radiant floor Control

More information

New Products in this Catalog

New Products in this Catalog New Products in this Catalog X-PERT Tubing - pg. 4 3-way Mixing Valves - pg. 50 Crete-Heat Insulated Floor Panels - pg. 10 3 & 4-way Mixing Valve Actuators - pg. 50 Residential Copper Manifolds - pg. 22

More information

RA 2000 Series RA 15/6T & TB Conversion Valve

RA 2000 Series RA 15/6T & TB Conversion Valve RA 2000 Series RA 15/6T & TB Conversion Valve Applications: RA15/6T Internal bypass allowing for series piping to the radiators/baseboards. This series piping provides continuous flow but the supply water

More information

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE SPECIFICATIONS... 1 OVERVIEW... 2 PRECAUTIONS... 2 MOUNTING LOCATION... 2 CONNECTION TO BOILER PRIMARY PIPING:... 3 ELECTRICAL CONNECTION... 4 FLUSHING THE

More information

propanel Series Installation Manual

propanel Series Installation Manual propanel Series Installation Manual propanel Series Installation Manual is published by Uponor Wirsbo 5925 148th Street West Apple Valley, MN 55124 (952) 891-2000 2003 Uponor Wirsbo All rights reserved

More information

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2 I&M NUMBER: 316-42-15-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

Radiator Valve Program

Radiator Valve Program Radiator Valve Program Heat seeks cold faster when the temperature difference is greater. Lowering the temperature of a room reduces the amount of heat leaving the room (heat loss). Installing thermostats

More information

Thermostatic Radiator Valves (Caleffi)

Thermostatic Radiator Valves (Caleffi) 02/09/16 B46 Thermostatic Radiator Valves (Caleffi) Thermostatic Control Heads Thermostatic control head fits radiator valves Set point locking mechanism Range stop adjustment Built-in sensor with liquid-filled

More information

Taco 00 Series Cartridge Circulators

Taco 00 Series Cartridge Circulators Water Circulation Pumps & Circulators Taco 00 Series Cartridge Circulators For over 70 years, Taco has led the industry with the highest quality circulators you can buy. Designed for a wide range of residential

More information

2.A MANIFOLD SHUNTS MINI SHUNTS

2.A MANIFOLD SHUNTS MINI SHUNTS 2.A MANIFOLD SHUNTS MINI SHUNTS ROTH HEATING SYSTEMS 2A. MANIFOLD SHUNTS Roth Manifold Shunts 4"/5.8cv and 1"/7.0cv Preassembled, manually adjusted, proportional temperature mixing station with built-in,

More information

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00 I&M NUMBER: 316-42-16-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

Installation and Testing of Inverted Bucket Steam Traps Manual

Installation and Testing of Inverted Bucket Steam Traps Manual Installation and Testing of Inverted Bucket Steam Traps Manual 307-EN Please read and save these instructions Armstrong IB Traps Installation Before Installing Run pipe to trap. Before installing the trap,

More information

Viessmann B1HA Boiler Series

Viessmann B1HA Boiler Series User Guide Version 1.0 Installation and Commissioning Guide www.tamashydronic.com Table of Contents Introduction... 3 Components... 4 Operation... 5 Technical Data... 6-7 Wiring... 8-9 Commissioning...

More information

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35 installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35 built on innovation acb 30 & 35 Active Chilled Beam Models ACB30 & ACB35 are designed for installation in the ceiling

More information

Crown Boiler Company

Crown Boiler Company Crown Boiler Company 1 Phantom Boiler System Combi Kit Instruction Manual I Product Description This kit adds the ability to generate DHW, as well as heat, ( combi capability) to select Phantom models

More information

installation, operation & Maintenance manual Floor-mounted Induction units

installation, operation & Maintenance manual Floor-mounted Induction units installation, operation & Maintenance manual Floor-mounted Induction units built on innovation induction units- fmfby/ fmlby/ fmtby Floor-mounted induction units FMFBY, FMLBY, & FMTBY are designed for

More information

Model 8330 Stainless Steel Combination Shower Eye/Face Wash

Model 8330 Stainless Steel Combination Shower Eye/Face Wash INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 8330 Stainless Steel Combination

More information

PureFlow. PureFlow. Fittings system This section doesn t meet California AB1953, Vermont ACT 193 and NSF 61 Annex G Standards.

PureFlow. PureFlow. Fittings system This section doesn t meet California AB1953, Vermont ACT 193 and NSF 61 Annex G Standards. Fittings system This section doesn t meet California AB1953, Vermont ACT 193 and NSF 1 Annex G Standards. 11 PEX Manifold Plumbing Systems # of Outlets: Dimension (hot,cold) MANABLOC -BRONZE PEX PRESS

More information

Compact Regenerative Air Dryers DE0 DE5 Series. Catalog 9CW-AW-220

Compact Regenerative Air Dryers DE0 DE5 Series. Catalog 9CW-AW-220 Compact Regenerative Air Dryers DE0 DE5 Series Catalog 9CW-AW-220 ! WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH,

More information

Security Alarm Monitoring Agreement

Security Alarm Monitoring Agreement Security Alarm Monitoring Agreement Master Licence: 405021230 Contract #: This Agreement is made between Western Plains Security & Locksmiths (Birkgate PTY LTD) and the customer as indicated below. Customer

More information

Hydronic Radiant and Snowmelt. Product Catalog. Living full of energy

Hydronic Radiant and Snowmelt. Product Catalog. Living full of energy Hydronic Radiant and Snowmelt Product Catalog Tubing Panel Systems Manifold and Mixing Stations Fittings and Tools Valves and Controls Living full of energy Hydronic and Radiant Heating Product Catalog

More information

Better Design, Better Control, Better Systems.

Better Design, Better Control, Better Systems. Product Catalog Better Design, Better Control, Better Systems. At tekmar Control Systems, we believe the indoor comfort of a building depends on the performance of its heating, ventilating & air conditioning

More information

KSD PEX Tubing Product Specifications

KSD PEX Tubing Product Specifications KSD PEX Tubing Product Specifications KSD PEX Hydronic for heating use KSD PEX Hydronic is a crosslinked polyethylene oxygen barrier tubing manufactured in accordance with NSF/ANSI 14, ASTM F876 and F877.

More information

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00 I&M NUMBER: 316-42-5-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Watlow heaters are built to comply with UL and CSA dielectric requirements, it may be

More information

Model Combination Shower Eye/Face Wash

Model Combination Shower Eye/Face Wash INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 8300.158 Combination Shower

More information

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

! The Caution Symbol (exclamation point) alerts you to a CAUTION, a safety or I&M NUMBER: 316-42-10-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL FloorHeat PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL Thank you for purchasing this radiant control panel assembly. Following are some important notes that will make the installation successful.

More information

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations Series 600 LFI / CFI Series 700 HFS Zone Control Stations Heating and Radiant Floor Zone Control Stations Installation Instructions Thank you for purchasing the finest in heating and radiant floor Control

More information

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Hot Water Tempered Water Outlet Cold Water Tempered Water Outlet Redundant Thermostatic Mixing Valve Hot Water

More information

FAN COIL NON-PROGRAMMABLE DIGITAL THERMOSTAT

FAN COIL NON-PROGRAMMABLE DIGITAL THERMOSTAT OWNER'S MANUAL FAN COIL NON-PROGRAMMABLE DIGITAL THERMOSTAT P/N E055-71520301 P/N E055-71520304 72 74 C OOL AUTO HEAT 70 2- or 4-pipe configurable Dual or Single Setpoint Very easy to program Large, easy

More information

Model 8300FP Freeze Resistant Combination Shower Eye/Face Wash

Model 8300FP Freeze Resistant Combination Shower Eye/Face Wash INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 8941-6467 (775) 59-4712 Fax (775) 59-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 800FP Freeze Resistant Combination

More information

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen Hydronic Mixing Block Version 1.104 The Hydronic Mixing Block is a mixing device and boiler control, with a built in circulator and system controller. The block can provide either a fixed or reset water

More information

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve VENT APPENDIX A: PIPING SYMBOL LEGEND GENERIC COMPONENTS CALEFFI COMPONENTS circulator circulator w/ ThermoBloc union circulator w/ swing check spring loaded balancing balancing w/ gate check globe s purging

More information

Apex Packaged Refrigeration System

Apex Packaged Refrigeration System Apex Packaged Refrigeration System INSTALLATION AND MAINTENANCE MANUAL Publication IOM H900.1 January, 2009 Table of Contents Inspection 1 Unit Placement Requirements 2 Installation Instruction 2 Before

More information

Model /8300CRP-8309CRP Shower & Eye/Face Wash

Model /8300CRP-8309CRP Shower & Eye/Face Wash INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 455 Kleppe Lane Sparks, NV 8943-6467 (775) 359-472 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 8300-8309/8300CRP-8309CRP

More information

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6 OWNERS MANUAL BOSS COMPRESSED AIR DRYER Distributed by Air & Vacuum Process, Inc. Phone: 281-866-9700 Fax: 281-866-9717 Email: sales@airvacuumprocess.com SAFETY... Page 2 MAINTENANCE... Page 5 INSTALLATION...

More information

INSTALLATION, OPERATION AND MAINTENANCE

INSTALLATION, OPERATION AND MAINTENANCE INLINE HEATER INSTALLATION, OPERATION AND MAINTENANCE MODELS: ILS SERIES 1.5kW 120V SINGLE PHASE BEFORE YOU BEGIN CHECK ALL ELECTRICAL CONNECTIONS TO ALL COMPONENTS WITHIN THE HEATER FOR TIGHTNESS. CONNECTIONS

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Installation and Maintenance Instructions AMERIVENT GAS RELINING KITS MODEL AFL This symbol on the product means the product is listed by Underwriters Laboratories, Inc. GENERAL INSTALLATION GUIDELINES

More information

Hydronic & HVAC Control Systems

Hydronic & HVAC Control Systems tekmar 218 Full Line Catalog Hydronic & HVAC Control Systems HVAC Multi-Staging Alternative Energy Zoning Snow Melting Setpoint tekmarcontrols.com tekmarcontrols.com Better Design, Better Control, Better

More information

CONNECTION SYSTEM AUGUST Reliance Worldwide USA

CONNECTION SYSTEM AUGUST Reliance Worldwide USA CONNECTION SYSTEM Reliance Worldwide USA AUGUST 2010 1-877-700-4242 www.sharkbitepro.com the sharkbite Connection system includes push-fit and barb products and pex tubing. Contents Introduction and Applications...........................................

More information

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

ICS Float and Thermostatic Steam Trap Installation and Operation Manual ICS Float and Thermostatic Steam Trap Installation and Operation Manual 59 Table of Contents. General Safety Information. 3 Product Information. 4 Product Installation. 5 Service and Maintenance. 6 Troubleshooting.

More information

INSTANT-FLOW C-MICRO WATER HEATER

INSTANT-FLOW C-MICRO WATER HEATER WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS (LOW ACTIVATION MODELS) TABLE OF CONTENTS Technical Information..................................... 2 Dimensional Data........................................

More information

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00 I&M NUMBER: 316-42-8-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet. Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet Angle Checkstop Angle Checkstop Hot Water Inlet G3700LF Cold Water Inlet Installation 1.

More information

Thermotech underfloor heating

Thermotech underfloor heating Thermotech underfloor heating Assortment and pricelist 2010 Copyright: Thermotech Scandinavia AB 2009 Cover photo: Michael Engman Graphic design: Ulrika Mattisson Other image material: Michael Engman,

More information

Model 8356WCSM Pull-Down Shower Eye/Face Wash

Model 8356WCSM Pull-Down Shower Eye/Face Wash INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 8941-6467 (775) 59-4712 Fax (775) 59-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 856WCSM Pull-Down Shower Eye/Face

More information

M3050 Detector Operator s Manual

M3050 Detector Operator s Manual FABRICON SYSTEMS ALBERTA 2008 INC. Keeping you in Front M3050 Detector Operator s Manual Telephone: (403)652-2127 Mailing Address: Shipping Address: Fax: (403)652-3027 Box 5996 402 Ellis Crescent S.E Email:

More information

Low Temperature Stainless Steel Panel Series Installation and Commissioning Guide

Low Temperature Stainless Steel Panel Series Installation and Commissioning Guide User Guide Version 2.0 Low Temperature Stainless Steel Panel Series Installation and Commissioning Guide www.tamashydronic.com Table of Contents Introduction... 3 Operation... 4 Components... 5-6 Technical

More information

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI Hydraulic Institute Standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Model /8320CRP Shower and Eye/Face Wash

Model /8320CRP Shower and Eye/Face Wash INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 8320-8325/8320CRP Shower

More information

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions 138-EN Please read and save these instructions Contents General Safety Information... 3 Product Information...3-5 Product

More information

CONNECTION SYSTEM Reliance Worldwide USA

CONNECTION SYSTEM Reliance Worldwide USA CONNECTION SYSTEM Reliance Worldwide USA AUGUST 2010 The SharkBite Connection System Includes Push-Fit and Barb Products and PEX tubing. CONTENTS Introduction and Applications...........................................

More information

Model 8356WCC Pull-Down Shower Eye/Face Wash

Model 8356WCC Pull-Down Shower Eye/Face Wash INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-646 (5) 359-412 Fax (5) 359-424 E-mail: haws@hawsco.com website: www.hawsco.com Model 8356WCC Pull-Down Shower Eye/Face

More information

Service Parts, Kits and Accessories

Service Parts, Kits and Accessories The parts identification guides on the following pages have been designed to give a quick reference to component parts used on pilot ignition agricultural building heaters. The guides identify components

More information

Heater Installation Kit

Heater Installation Kit Instructions - Parts Heater Installation Kit 30677B Part No. 248428 Includes parts needed to install VISCON HP heater onto cart. Order VISCON HP heater separately. Important Safety Instructions Read all

More information

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer 1/2" OD Copper Tube Inlets Hot Water Inlet Cold Water Inlet G3600LF Installation 1. Install valve in

More information

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Pipe and Pipe Fittings. B. Air compressor. C. Air receiver and accessories. D. Aftercooler. E. Refrigerated air dryer. F. Pressure reducing station. 1.02 RELATED

More information

BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF

BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS Product Submittal A PART OF Limited Warranty SprinkFLEX warrants that its products will be free from defects in materials and workmanship under normal conditions

More information

installation, operation & Maintenance manual acb ceiling-mounted cassette models

installation, operation & Maintenance manual acb ceiling-mounted cassette models installation, operation & Maintenance manual acb ceiling-mounted cassette models built on innovation Active chilled beams Active Chilled Beam cassette style beams are induction driven, heating and cooling

More information

RESIDENTIAL REBATE FORM

RESIDENTIAL REBATE FORM OIL & PROPANE HEATING & WATER HEATING 2019 RESIDENTIAL REBATE FORM s of up to $2,300 are available for high-efficiency replacement furnaces, boilers, s, weather responsive controls and thermostats. 800-232-0672

More information

CITY OF LOCKPORT FIRE SPRINKLER & FIRE ALARM SYSTEM INSTALLATION ASSISTANCE PROGRAM

CITY OF LOCKPORT FIRE SPRINKLER & FIRE ALARM SYSTEM INSTALLATION ASSISTANCE PROGRAM CITY OF LOCKPORT FIRE SPRINKLER & FIRE ALARM SYSTEM INSTALLATION ASSISTANCE PROGRAM The City of Lockport has implemented a Fire Sprinkler & Fire Alarm System Installation Assistance Program for eligible

More information

ILLUSTRATED PARTS LIST

ILLUSTRATED PARTS LIST ILLUSTRATED PARTS LIST MODELS 200DW 200G 300G 900DW 900G 200DW 3000 & 6000P For additional information on Thermodyne Foodservice Products, Inc., or to locate an authorized parts and service provider in

More information

EB Mawson & Sons Pty Ltd Trading as Mildura Mini Mix and Garden Supplies

EB Mawson & Sons Pty Ltd Trading as Mildura Mini Mix and Garden Supplies EB Mawson & Sons Pty Ltd Trading as Mildura Mini Mix and Garden Supplies Terms & Conditions of Trade E.B. Mawson & Sons Pty Ltd December 2011 Edition Page 1 of 11 1. Definitions 1.1 Mildura Mini Mix and

More information

Settlement Agreement. Schedule 1: Covered Products

Settlement Agreement. Schedule 1: Covered Products Settlement Agreement Schedule 1: Covered Products COVERED PRODUCT BRANDS BRASSCRAFT PLUMBSHOP PEERLESS SOLUTIONS MASTER PLUMBER COVERED PRODUCT CATEGORIES - WATER SUPPLIES SUPPLY STOPS WATER SUPPLY CONNECTORS

More information

Price List LT-WS0414 EFFECTIVE DATE: APRIL 1, 2014 SUPERSEDES JAN 31, 2011 PRICE LIST. It's all about performance

Price List LT-WS0414 EFFECTIVE DATE: APRIL 1, 2014 SUPERSEDES JAN 31, 2011 PRICE LIST. It's all about performance Price List LT-WS0414 APRIL 1, 2014 SUPERSEDES JAN 31, 2011 PRICE LIST It's all about performance Indexed Tabs Find the product you need quickly by referring to the color tabs on each page. BALL VALVES

More information

Armstrong ExpressPack Multi-Tube Steam Dispersion Panel Assembly and Installation Instructions

Armstrong ExpressPack Multi-Tube Steam Dispersion Panel Assembly and Installation Instructions Armstrong ExpressPack Multi-Tube Steam Dispersion Panel Assembly and Installation Instructions IOM-573 This bulletin should be used by experienced personnel as a guide to the installation and maintenance

More information

Instruction Sheet 00 Variable Speed Delta T (00-VDT)

Instruction Sheet 00 Variable Speed Delta T (00-VDT) Instruction Sheet 00 Variable Speed Delta T (00-VDT) 102-359 SUPERSEDES: January 1, 2010 EFFECTIVE: May 1, 2010 Plant ID# 001-3927 The Variable Speed Delta T 00 Cartridge Circulator (00-VDT) is a microprocessor-based

More information

Clean. Safe. Reliable. WaterPEX.

Clean. Safe. Reliable. WaterPEX. Clean. Safe. Reliable. WaterPEX. Our Complete System of Pipes, Valves, and Fittings for Plumbing is Even More Comprehensive The future of plumbing systems is WaterPEX. W ith 125 years of experience, Watts

More information

ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL EFFECTIVE MAY, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified are

More information

CONNECTION SYSTEM JULY

CONNECTION SYSTEM JULY CONNECTION SYSTEM JULY 2009 IT ALL STARTED WITH A DEEP NEED FOR THE MOST RELIABLE VALVES EVER BUILT. The year was 1893 when the young engineer A.W. Cash was given the toughest challenge of his career:

More information

Rittling Fanvector. Installation, Operation and Maintenance. Cooling Fresh Air Clean Air

Rittling Fanvector. Installation, Operation and Maintenance. Cooling Fresh Air Clean Air Rittling Fanvector Installation, Operation and Maintenance Heating Cooling Fresh Air Clean Air i Arrangements 1 General information 1 Dimensions and data 2 Installation 6 Wiring diagram 9 Operation 10

More information

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet Cold Water Thermometer Hot Water Inline Check Redundant Thermostatic Mixing Valve Angle Checkstops

More information

INSTRUCTION MANUAL HS-229G

INSTRUCTION MANUAL HS-229G INSTRUCTION MANUAL HS-229G 510977 STEP 1 - Where to Install the Thermostatic Steam Trap Determine where to install the thermostatic steam trap based on the following information. a. The trap should be

More information

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N CLIMAGUARD Air-to-Air Outdoor Heat Exchangers TX23, TX33, TX38, TX52 Model INSTRUCTION MANUAL Rev. H 2015 Pentair Equipment Protection P/N 10-1008-221 87976519 TABLE OF CONTENTS RECEIVING THE HEAT EXCHANGER...3

More information

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00 I&M NUMBER: 316-42-2-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to elements

More information

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company Overview The DEMA Easy Dose is a simple and reliable chemical delivery system. Easy Dose features an electronic control system

More information

HPS Controls Ltd. Series 100 LTV / CTV Zone Control Stations. Heating and Radiant Floor Zone Control Stations. Installation Instructions

HPS Controls Ltd. Series 100 LTV / CTV Zone Control Stations. Heating and Radiant Floor Zone Control Stations. Installation Instructions Series 100 LTV / CTV Zone Control Stations Heating and Radiant Floor Zone Control Stations Installation Instructions Thank you for purchasing the finest in heating and radiant floor Control Stations. We

More information

NIBCO Radiant Panel Model RHP-2-4

NIBCO Radiant Panel Model RHP-2-4 NIBCO Radiant Panel Model RHP-2-4 1 Table of Contents Cover Page 1 Table of Contents 2 Warning Symbols 3 Safety Warnings 4 Definitions 5 Introduction 6 Specifications and Restrictions 7 Panel Picture with

More information

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 9001EXP Alarm No. 2080203(24)

More information

Automatic Temperature Controller (ATC)

Automatic Temperature Controller (ATC) NEW FROM APOLLO...THE FIRST MULTIPLE-FIXTURE HI-LO MIXING VALVE THAT MEETS ASSE 1017 AND THE NEW ASSE 1069 STANDARD Only Apollo offers fast delivery on the first water temperature mixing assembly to meet

More information

Tube Clamp Submittal Information Revision A: July 25, 2013

Tube Clamp Submittal Information Revision A: July 25, 2013 Tube Clamp Revision A: July 25, 2013 Polypropylene (PP) Tube Clamps secure ½" and ¾" Uponor crosslinked polyethylene (PEX-a) tubing products. Suspension Standard Description Part Number A B C Weight Tube

More information

Multiple Boilers Electro TS Series Application EB-C-STG5

Multiple Boilers Electro TS Series Application EB-C-STG5 Multiple Boilers Electro TS Series Application EB-C-STG5 Drawings: BC025 BX404 BH504 XX017 Information All Electro-Boilers, except Mini-Boiler, have the same control board (EB5623**). The plug-in control

More information

Making Crimp Connections

Making Crimp Connections Making Crimp Connections Cut tube off square (90 ) with a tube cutter. Tube Cutter Slide the PEX crimp ring over the end end of the tube. BE SURE the crimp ring is centered over the PEX barb. Slide the

More information