Super. Digital Inverter. Inverter Air Conditioning for Light Commercial Use
|
|
- Jemimah Ford
- 6 years ago
- Views:
Transcription
1 Super Digital Inverter Inverter Air Conditioning for Light Commercial Use
2 Super Digital Inverter Toshiba Super Digital Inverter series air conditioners combine economy and ecology in a compact body. They feature state-of-the-art technology, flexible control, and easy installation to bring natural comfort and convenience to any business environment. A complete range of indoor units: Cassette, Ducted, Ceiling and High wall units. Superior EER Very efficient energy consumption, Keeps down operating costs. EER of 4.52* and COP of 4.79* achieved by Toshiba s unrivalled Super Digital Inverter technologies and newly developed components. 4-way cassette / Cooling (EER) way cassette / Heating (COP) *4HP outdoor unit HP 3 HP 4 HP 5 HP HP 3 HP 4 HP 5 HP Rated 50% load The industry's first magnetic-action control Current model New model Magnetic action Magnetic center The new structure allows a huge reduction in energy loss. The balanced magnetic-action force to rise and the rotor s weight minimized the friction laid on the axis provides excellent operation efficiency. Stator Rotor Rotor s weight Friction loss Reducing friction loss ECO-driving DC twin rotary Vector-controlled inverter Vector IPDU control changes the motor current wave to a smooth sine pattern so that noise emitted from the drive units is greatly reduced. High efficiency heat-transfer (flat fin) Heat-transfer tube with improved heat-transfer coefficient. R410A refrigerant An ozone layer depletion coefficient of zero has become absolutely essential for an advanced air conditioning system. A low minimum speed of 10 rps has been achieved. This has further improved the operating efficiency when the load is low (the minimum in Series 2 was 15 rps). High power motor DC fan motor Highly Efficient DC Motor. Bat wing fan New development for high-pressure low-volume fan. Wide-flow grille Optimizing ventilation performance, Bringing out the full effect of fan and motor. DC twin rotary compressor A low minimum speed of 10 rps has been achieved. Large-area magnet Rotor with slit Newly designed compression path More precise components The structure and shape of each compressor component has been optimised. The area of the rotor magnet has been increased and a slit introduced to the design. These improvements have further enhanced efficiency and reduced noise. 2 Note: Actual component may vary considerably from specifications depending on product model.
3 Operating temperature range Heater operation is possible starting from an outdoor temperature of -20 C creates a comfortable space even during cold winters, while cooling operation is possible at -15 C outdoor temperature. This enables wider applications and use of the system in colder regions. Heating operation range SDl (2-6HP) SDl ( HP) -20 C -15 C 0 C 15 C Heating: C WB Self-Clean operation-continuing high performance for energy saving This enables indoor unit type and Ceiling type to maintain energy efficiency at the time of purchase for a long time. The mechanism of the wash-off 1. The aqua resin coating prevents dirt from sticking to the fins. 2. The condensation water flows and washes away dirt. Water 3. After washing, a drying operation suppresses the Oil/ Dirt propagation of mold. Quiet operation Aqua resin coating Low-noise design. If the outdoor temperature is 30 C or less, operates at under 45dB(A). It s possible to automatically operate the quiet operation mode below 35 C air temperature. Frost protection 8 C operation for frost protection is possible for the combination with Super Digital Inverter. (4-Way and Slim Duct series 4) Sub cool path Improve reliability for smooth drainage. The outdoor unit of Super Digital Inverter is equipped with Sub cool path preventing freeze under a heat exchanger. (Only 3HP to 6HP) Annual operation (h) Operation below air temperature 30 ( C) Air temperaure ( C) Rear side Operation sound db(a) Piping panel taken out in 4 directions Height Difference Super Digital Inverter leads the industry with support for height differences of up to 30 meters on a single system. That is enough height to cover an 8-story building. Height between indoor units 30m 8F 7F 6F 5F 4F 3F 2F 1F Single system Sub cool path Front Compatible with pipes up to 75 meters long Enable the outdoor unit to be installed out of sight increases installation flexibility. (Only 4HP to 6HP) Under Farthest equivalent length 75m Rear Lateral 3
4 Super Digital Inverter Combinations 1-phase model Equivalent (HP) 1.5HP 1.7HP 2HP 3HP 4HP 5HP 6HP Standard RAV-SP404ATP-E RAV-SP454ATP-E RAV-SP564ATP-E RAV-SP804ATP-E RAV-SP1104AT-E RAV-SP1404AT-E - Light Anti-Corrosion protection RAV-SP1104ATZ-E RAV-SP1404ATZ-E - Heavy Anti-Corrosion protection - - RAV-SP564ATJP-E RAV-SP804ATJP-E RAV-SP1104ATZG-E RAV-SP1404ATZG-E - 3-phase model 50Hz 60Hz Standard RAV-SP1104AT8-E RAV-SP1404AT8-E RAV-SP1604AT8-E Light Anti-Corrosion protection RAV-SP1104AT8Z-E RAV-SP1404AT8Z-E RAV-SP1604AT8Z-E Heavy Anti-Corrosion protection RAV-SP1104AT8ZG-E RAV-SP1404AT8ZG-E RAV-SP1604AT8ZG-E Standard RAV-SP1104AT7 RAV-SP1404AT7 RAV-SP1604AT7 Light Anti-Corrosion protection RAV-SP1104AT7Z RAV-SP1404AT7Z RAV-SP1604AT7Z Heavy Anti-Corrosion protection RAV-SP1104AT7ZG RAV-SP1404AT7ZG RAV-SP104AT7ZG Compact 4-way cassette type Single RAV-SM404MUT-E RAV-SM454MUT-E RAV-SM564MUT-E N/A N/A N/A N/A Twin (x 2) N/A N/A N/A RAV-SM404MUT-E RAV-SM564MUT-E N/A N/A Triple (x 3) N/A N/A N/A N/A N/A N/A RAV-SM564MUT-E 4-way cassette type Single N/A N/A RAV-SM564UTP-E RAV-SM804UTP-E RAV-SM1104UTP-E RAV-SM1404UTP-E RAV-SM1604UTP-E Twin (x 2) N/A N/A N/A N/A RAV-SM564UTP-E RAV-SM804UTP-E RAV-SM804UTP-E Triple (x 3) N/A N/A N/A N/A N/A N/A RAV-SM564UTP-E Slim duct type Single RAV-SM404SDT-E RAV-SM454SDT-E RAV-SM564SDT-E N/A N/A N/A N/A Twin (x 2) N/A N/A N/A RAV-SM404SDT-E RAV-SM564SDT-E N/A N/A Triple (x 3) N/A N/A N/A N/A N/A N/A RAV-SM564SDT-E Standard duct type Single RAV-SM406BTP-E RAV-SM456BTP-E RAV-SM566BTP-E RAV-SM806BTP-E RAV-SM1106BTP-E RAV-SM1406BTP-E RAV-SM1606BTP-E Twin (x 2) N/A N/A N/A RAV-SM406BTP-E RAV-SM566BTP-E RAV-SM806BTP-E RAV-SM806BTP-E Triple (x 3) N/A N/A N/A N/A N/A N/A RAV-SM566BTP-E Ceiling type Single N/A N/A RAV-SM567CTP-E RAV-SM807CTP-E RAV-SM1107CTP-E RAV-SM1407CTP-E RAV-SM1607CTP-E Twin (x 2) N/A N/A N/A N/A RAV-SM567CTP-E RAV-SM807CTP-E RAV-SM807CTP-E Triple (x 3) N/A N/A N/A N/A N/A N/A RAV-SM567CTP-E High wall type Single N/A N/A RAV-SM566KRT-E RAV-SM806KRT-E N/A N/A N/A Twin (x 2) N/A N/A N/A N/A RAV-SM566KRT-E RAV-SM806KRT-E RAV-SM806KRT-E Triple (x 3) N/A N/A N/A N/A N/A N/A RAV-SM566KRT-E 4
5 Available Indoor Units 5
6 Compact 4-way cassette type Perfectly fit for 600 x 600 grid system ceiling Perfect for grid system ceiling This compact unit (575 x 575 mm) fits perfectly into ceilings and matches standard architectural modules, without the need to cut ceiling tiles. Panel Designed for simple & easy installation and maintenance The slim flat stylish panel design is only 268 mm in height even when an electrical box is located inside the unit. Easy access to electrical box is achieved by simply removing the suction grill. Easy installation is also possible using the panel adjust pocket. Use the adjust pocket function for fine adjustments after installation. The drain up height is 850 mm. Available for ceilings up to 3.5 m in height. 3.5m RBC-UM11PG(W)-E Maximum height (RAV-) SM404MUT-E SM454MUT-E SM564MUT-E Outdoor unit Power supply Cooling* 1 Heating* 1 Standard (RAV-) SP404ATP-E SP454ATP-E SP564ATP-E Light Anti-Corrosion protection (RAV-) Heavy Anti-Corrosion protection (RAV-) - - SP564ATJP-E 1-phase 50Hz 230V ( V) Capacity kw Range, min-max kw Power consumption kw EER (Energy Efficiency Ratio) Capacity 100% Capacity 80% Capacity 50% Capacity kw Range, min-max kw Power consumption kw COP (Coefficient of Performance) Capacity 100% Capacity 80% Capacity 50% Standard air flow (H/M/L) m 3 /h 660/552/ /552/ /672/546 Sound pressure level (H/M/L) db(a) 40/36/31 40/36/31 43/39/34 Sound power level (H/M/L) db(a) 55/51/46 55/51/46 58/54/49 Main unit dimensions (H/W/D) mm 268/575/ /575/ /575/575 Weight kg Panel dimensions (H/W/D) mm 27/700/700 27/700/700 27/700/700 Panel weight kg Outdoor unit Compressor type DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø12.7 / ø6.4 ø12.7 / ø6.4 Standard / Min. pipe length m 7.5 / / / 5 Max. pipe total length m Maximum height difference m Outer dimensions (H/W/D) mm 550/780/ /780/ /780/290 Weight kg Standard air flow (Fan unit) m 3 /h Sound pressure level, Cooling/Heating* 2 db(a) 45/47 45/47 47/48 Sound power level, Cooling/Heating db(a) 62/64 62/64 63/64 Operating range, Cooling/Heating C -15~43 / -15~15-15~43 / -20~15 Options Auxiliary fresh air flange TCB-FF101URE2 Panel RBC-UM11PG(W)E 6 *1 Rated conditions Cooling : Indoor air temperature 27 o C DB / 19 o C WB, Outdoor air temperature 35 o C DB Heating : Indoor air temperature 20 o C DB, Outdoor air temperature 7 o C DB / 6 o C WB *2 Sound pressure levels measured in an anechoic chamber
7 4-way cassette type The wide air flow in all direction Multi-louver individual control Individual louver control enables airflow to be chosen according to user preferences. The angles of each louver can be set individually in 3 different choices of swing patterns; Standard swing, Diagonally opposite swing and Turn-around swing (1) Standard swing (2) Diagonally opposite swing New Long-life pre-filter A new long-life pre-filter has a surface 1.5 times of current filters to improve Dustcollection performance. Easy installation Light weight unit (24kg at 5HP) Easy panel installation, The panel is attached using the bolt that is already installed on the indoor unit. (3) Turn-around swing Built-in condensate drain pump 300mm or less 850mm or less 210mm (RAV-) SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E SM1104UTP-E SM1404UTP-E SM1604UTP-E Outdoor unit Standard (RAV-) SP564ATP-E SP804ATP-E SP1104AT-E SP1404AT-E Light Anti-Corrosion protection (RAV-) - - SP1104ATZ-E SP1404ATZ-E Heavy Anti-Corrosion protection (RAV-) SP564ATJP-E SP804ATJP-E SP1104ATZG-E SP1404ATZG-E SP1104AT8-E, SP1104AT7 SP1104AT8Z-E, SP1104AT7Z SP1104AT8ZG-E, SP1104AT7ZG SP1404AT8-E, SP1404AT7 SP1404AT8Z-E, SP1404AT7Z SP1404AT8ZG-E, SP1404AT7ZG SP1604AT8-E, SP1604AT7 SP1604AT8Z-E, SP1604AT7Z SP1604AT8ZG-E, SP1604AT7ZG Power supply 1-phase 50Hz 230V ( V) / 1-phase 60Hz 220V 3-phase 50Hz 400V ( V) / 3-phase 60Hz 380V Cooling* 1 Heating* 1 Capacity kw Range, min-max kw Power consumption kw EER (Energy Efficiency Ratio) Capacity 100% Capacity 80% Capacity 50% Capacity kw Range, min-max kw Power consumption kw COP (Coefficient of Performance) Capacity 100% Capacity 80% Capacity 50% Standard air flow (H/M/L) m 3 /h 1050/870/ /960/ /1440/ /1440/ /1440/ /1440/ /1500/1260 Sound pressure level (H/M/L) db(a) 32/29/28 35/31/28 43/38/33 44/38/34 43/38/33 44/38/34 45/40/36 Sound power level (H/M/L) db(a) 47/44/43 50/46/43 58/53/48 59/53/49 58/53/48 59/53/49 60/55/51 Main unit dimensions (H/W/D) mm 256/840/ /840/ /840/ /840/ /840/ /840/ /840/840 Weight kg Panel dimensions (H/W/D) mm 30/950/950 30/950/950 30/950/950 30/950/950 30/950/950 30/950/950 30/950/950 Panel weight kg Outdoor unit Compressor type DC twin rotary DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 Standard / Min. pipe length m 7.5 / / / / / / / 3 Max. pipe total length m Maximum height difference m Outer dimensions (H/W/D) mm 550/780/ /900/ /900/ /900/ /900/ /900/ /900/320 Weight kg Standard air flow (Fan unit) m 3 /h Sound pressure level, Cooling/Heating* 2 db(a) 47/48 48/49 49/50 51/52 49/50 51/52 51/53 Sound power level, Cooling/Heating db(a) 63/64 64/65 66/67 68/69 66/67 68/69 68/70 Operating range, Cooling/Heating C -15~43 / -20~15-15~46 / -20~15 *1 Rated conditions Cooling : Indoor air temperature 27 o C DB / 19 o C WB, Outdoor air temperature 35 o C DB Heating : Indoor air temperature 20 o C DB, Outdoor air temperature 7 o C DB / 6 o C WB *2 Sound pressure levels measured in an anechoic chamber 7 RAV-SPxx04AT8(Z),(ZG)-E: 3-phase 50Hz 400V ( V), RAV-SPxx04AT7(Z),(ZG): 3-phase 60Hz 380V
8 Slim duct type Slim design for greater application flexibility Functional design Only 210 mm in height for greater application flexibility. 4-step static pressure setup. Concealed installation within a ceiling void. Auxiliary fresh air intake available. Slim & quiet Quiet, powerful operation. Perfect comfort throughout the room and can be used with any style of air diffuser. 210mm 210mm (RAV-) SM404SDT-E SM454SDT-E SM564SDT-E Outdoor unit Power supply Cooling* 1 Heating* 1 Standard (RAV-) SP404ATP-E SP454ATP-E SP564ATP-E Light Anti-Corrosion protection (RAV-) Heavy Anti-Corrosion protection (RAV-) - - SP564ATJP-E 1-phase 50Hz 230V ( V) Capacity kw Range, min-max kw Power consumption kw EER (Energy Efficiency Ratio) Capacity 100% Capacity 80% Capacity 50% Capacity kw Range, min-max kw Power consumption kw COP (Coefficient of Performance) Capacity 100% Capacity 80% Capacity 50% Standard air flow (H/M/L) m 3 /h 690/600/ /600/ /678/582 External static pressure-standard (Upper-Lower) Pa Sound pressure level-under air inlet db(a) 39/36/33 39/36/33 45/40/36 Sound pressure level-back air inlet db(a) 30/28/26 30/28/26 33/31/28 Sound power level (H/M/L) db(a) 54/51/48 54/51/48 60/55/54 Dimensions (H/W/D) mm 210/845/ /845/ /845/645 Weight kg Outdoor unit Compressor type DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø12.7 / ø6.4 ø12.7 / ø6.4 Standard / Min. pipe length m 7.5 / / / 5 Max. pipe total length m Maximum height difference m Outer dimensions (H/W/D) mm 550/780/ /780/ /780/290 Weight kg Standard air flow (Fan unit) m 3 /h Sound pressure level, Cooling/Heating* 2 db(a) 45/47 45/47 47/48 Sound power level, Cooling/Heating db(a) 62/64 62/64 63/64 Operating range, Cooling/Heating C -15~43 / -15~15-15~43 / -20~15 Options Auxiliary fresh air flange TCB-FF101URE2 8 *1 Rated conditions Cooling : Indoor air temperature 27 o C DB / 19 o C WB, Outdoor air temperature 35 o C DB Heating : Indoor air temperature 20 o C DB, Outdoor air temperature 7 o C DB / 6 o C WB *2 Sound pressure levels measured in an anechoic chamber
9 Standard duct type Wide range of application opportunities Compact sizing Compact size especially in height (275 mm), new slimmer chassis offers wide range of installation opportunities to customer. Built-in High-lift drain pump The flexible piping layout is made possible by an optionally available drain-pump kit that raises the drain piping up to 850 cm from the drain port. High static pressure External static pressure can be raised as high as 120 Pa, so that all areas of the room can be reached for even temperature distribution, no matter how complex the layout. Flexible duct is accessible, Allows complete design flexibility New spigot shaped flange as new accessories New spigot shaped flange has higher static pressure with optimized design, the static pressure drops only 20Pa from rectangle flange states. Maximum Static pressure will be 100Pa* with all models. (*static pressure with filter which included in, and intake from back ward) (RAV-) SM406BTP-E SM456BTP-E SM566BTP-E SM806BTP-E SM1106BTP-E SM1406BTP-E SM1106BTP-E SM1406BTP-E SM1606BTP-E Outdoor unit Standard (RAV-) SP404ATP-E SP454ATP-E SP564ATP-E SP804ATP-E SP1104AT-E SP1404AT-E Light Anti-Corrosion protection (RAV-) SP1104ATZ-E SP1404ATZ-E Heavy Anti-Corrosion protection (RAV-) - - SP564ATJP-E SP804ATJP-E SP1104ATZG-E SP1404ATZG-E SP1104AT8-E, SP1104AT7 SP1104AT8Z-E, SP1104AT7Z SP1104AT8ZG-E, SP1104AT7ZG SP1404AT8-E, SP1404AT7 SP1404AT8Z-E, SP1404AT7Z SP1404AT8ZG-E, SP1404AT7ZG SP1604AT8-E, SP1604AT7 SP1604AT8Z-E, SP1604AT7Z SP1604AT8ZG-E, SP1604AT7ZG Power supply 1-phase 50Hz 230V ( V) / 1-phase 60Hz 220V 3-phase 50Hz 400V ( V) / 3-phase 60Hz 380V Cooling* 1 Heating* 1 Capacity kw Range, min-max kw Power consumption kw EER (Energy Efficiency Ratio) Capacity 100% Capacity 80% Capacity 50% Capacity kw Range, min-max kw Power consumption kw COP (Coefficient of Performance) Capacity 100% Capacity 80% Capacity 50% Standard air flow (H/M/L) m 3 /h 798/630/ /630/ /630/ /930/ /1650/ /1650/ /1650/ /1650/ /1650/1260 External static pressure (factory setting) Pa External static pressure-standard (Upper-Lower) Pa 30(120-30) 30(120-30) 50(120-30) (7 steps) Sound pressure level (H/M/L) db(a) 33/29/25 33/29/25 33/29/25 34/30/26 40/36/33 40/36/33 40/36/33 40/36/33 40/36/33 Sound power level (H/M/L) db(a) 48/44/40 48/44/40 48/44/40 49/45/41 55/51/48 55/51/48 55/51/48 55/51/48 55/51/48 Dimensions (H/W/D) mm 275/700/ /700/ /700/ /1000/750275/1400/ /1400/ /1400/ /1400/ /1400/750 Weight kg Outdoor unit Polygonal rooms Narrow rooms Rooms with fixtures and obstacles Compressor type DC twin rotary DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 Standard / Min. pipe length m 7.5 / / / / / / 3 Max. pipe total length m Maximum height difference m Outer dimensions (H/W/D) mm 550/780/ /780/ /780/ /900/ /900/ /900/ /900/ /900/320 Weight kg Standard air flow (Fan unit) m 3 /h Sound pressure level, Cooling/Heating* 2 db(a) 45/47 45/47 47/48 48/49 49/50 51/52 49/50 51/52 51/53 Sound power level, Cooling/Heating db(a) 62/64 62/64 63/64 64/65 66/67 68/69 66/67 68/69 68/70 Operating range, Cooling/Heating C -15~43 / -15~15-15~43 / -20~15-15~46 / -20~15 *1 Rated conditions Cooling : Indoor air temperature 27 o C DB / 19 o C WB, Outdoor air temperature 35 o C DB Heating : Indoor air temperature 20 o C DB, Outdoor air temperature 7 o C DB / 6 o C WB *2 Sound pressure levels measured in an anechoic chamber 9 RAV-SPxx04AT8(Z),(ZG)-E: 3-phase 50Hz 400V ( V), RAV-SPxx04AT7(Z),(ZG): 3-phase 60Hz 380V
10 Ceiling type Smooth curve design & Low noise level Smooth Curve for pliant Shape Flap control New Designed Wide Flap All-new chassis and new rounded design, This new models have been developed in response to customers needs for ceiling units that better match their room interiors. Comfortable ambience The airflow angle is automatically set to the most suitable setting according to your cooling or heating needs, and an automatic swing mode enables airflow to reach all areas of the room to create a comfortable ambience. New fan has adopted the turbulence prevention rib to optimize the ventilating way. Air volume has increased and noise level also has decreased compared with previous model. Winds of new ceiling type of 4HP to 6HP can be reached up to 4.3 metre. Temperature measuring section Center 8m The new air outlet has realized both High noise reduction and large air volume. 8m Previous model New model 30% Extension 3m Previous model New model New Drain pump kit available as an option 8m 8m The Drain pump kit makes draining easier. Glass built into Drain Pump Kit helps reduce mould formation. 3m 0.5m above the floor Temperature (deg.c) (C) (RAV-) SM567CTP-E SM807CTP-E SM1107CTP-E SM1407CTP-E SM1107CTP-E SM1407CTP-E SM1607CTP-E Outdoor unit Standard (RAV-) SP564ATP-E SP804ATP-E SP1104AT-E SP1404AT-E Light Anti-Corrosion protection (RAV-) - - SP1104ATZ-E SP1404ATZ-E Heavy Anti-Corrosion protection (RAV-) SP564ATJP-E SP804ATJP-E SP1104ATZG-E SP1404ATZG-E SP1104AT8-E, SP1104AT7 SP1104AT8Z-E, SP1104AT7Z SP1104AT8ZG-E, SP1104AT7ZG SP1404AT8-E, SP1404AT7 SP1404AT8Z-E, SP1404AT7Z SP1404AT8ZG-E, SP1404AT7ZG SP1604AT8-E, SP1604AT7 SP1604AT8Z-E, SP1604AT7Z SP1604AT8ZG-E, SP1604AT7ZG Power supply 1-phase 50Hz 230V ( V) / 1-phase 60Hz 220V 3-phase 50Hz 400V ( V) / 3-phase 60Hz 380V Cooling* 1 Heating* 1 Capacity kw Range, min-max kw Power consumption kw EER (Energy Efficiency Ratio) Capacity 100% Capacity 80% Capacity 50% Capacity kw Range, min-max kw Power consumption kw COP (Coefficient of Performance) Capacity 100% Capacity 80% Capacity 50% Standard air flow (H/M/L) m 3 /h 900/720/ /1002/ /1350/ /1530/ /1350/ /1530/ /1530/1260 Sound pressure level (H/M/L) db(a) 37/35/28 41/36/29 44/38/32 46/41/35 44/38/32 46/41/35 46/42/36 Sound power level (H/M/L) db(a) 52/50/43 56/51/44 59/53/47 61/56/50 59/53/47 61/56/50 61/57/51 Dimensions (H/W/D) mm 235/950/ /1270/ /1586/ /1586/ /1586/ /1586/ /1586/690 Weight kg Outdoor unit Compressor type DC twin rotary DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 Standard / Min. pipe length m 7.5 / / / / / / / 3 Max. pipe total length m Maximum height difference m Outer dimensions (H/W/D) mm 550/780/ /900/ /900/ /900/ /900/ /900/ /900/320 Weight kg Standard air flow (Fan unit) m 3 /h Sound pressure level, Cooling/Heating* 2 db(a) 47/48 48/49 49/50 51/52 49/50 51/52 51/53 Sound power level, Cooling/Heating db(a) 63/64 64/65 66/67 68/69 66/67 68/69 68/70 Operating range, Cooling/Heating C -15~43 / -20~15-15~46 / -20~15 10 *1 Rated conditions Cooling : Indoor air temperature 27 o C DB / 19 o C WB, Outdoor air temperature 35 o C DB Heating : Indoor air temperature 20 o C DB, Outdoor air temperature 7 o C DB / 6 o C WB *2 Sound pressure levels measured in an anechoic chamber RAV-SPxx04AT8(Z),(ZG)-E: 3-phase 50Hz 400V ( V), RAV-SPxx04AT7(Z),(ZG): 3-phase 60Hz 380V
11 High wall type Elegant and slim Slim-line design With is attractive, slim-line design, the unit can easily blend in with any room interior. The filtration system further the indoor air quality benefits of this high-wall unit. Self cleaning function Toshiba s self-cleaning function is designed to reduce the humidity that causes mold to form inside an air-conditioning unit 20 minutes of fan operation after shut down dries the moist air and helps reduce mold formation on heat exchanger coils. Optimum air distribution 70 directional Auto-swing louver mode allows optimum air distribution throughout the room. Total comfort is granted, thanks also to Automatic air volume control and Automatic cooling/heating. Cooling mode Heating mode Cooling Normal Operation Moisture stays trapped inside Self-cleaning Function 20 minutes of fan operation after shut down dries the moist air and helps reduce mold formation on heat exchanger coils. SWING (RAV-) SM566KRT-E SM806KRT-E Outdoor unit Power supply Cooling* 1 Heating* 1 Standard (RAV-) SP564ATP-E SP804ATP-E Light Anti-Corrosion protection (RAV-) - - Heavy Anti-Corrosion protection (RAV-) SP564ATJP-E SP804ATJP-E 1-phase 50Hz 230V ( V) / 1-phase 60Hz 220V Capacity kw Range, min-max kw Power consumption kw EER (Energy Efficiency Ratio) Capacity 100% Capacity 80% Capacity 50% Capacity kw Range, min-max kw Power consumption kw COP (Coefficient of Performance) Capacity 100% Capacity 80% Capacity 50% Standard air flow (H/M/L) m 3 /h 840/750/ /750/660 Sound pressure level (H/M/L) db(a) 42/39/36 47/41/36 Sound power level (H/M/L) db(a) 57/54/51 62/56/51 Dimensions (H/W/D) mm 320/1050/ /1050/228 Weight kg Outdoor unit Compressor type DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø15.9 / ø9.5 Standard / Min. pipe length m 7.5 / / 5 Max. pipe total length m Maximum height difference m Outer dimensions (H/W/D) mm 550/780/ /900/320 Weight kg Standard air flow (Fan unit) m 3 /h Sound pressure level, Cooling/Heating* 2 db(a) 47/48 48/49 Sound power level, Cooling/Heating db(a) 63/64 64/65 Operating range, Cooling/Heating C -15~43 / -20~15 *1 Rated conditions Cooling : Indoor air temperature 27 o C DB / 19 o C WB, Outdoor air temperature 35 o C DB Heating : Indoor air temperature 20 o C DB, Outdoor air temperature 7 o C DB / 6 o C WB *2 Sound pressure levels measured in an anechoic chamber 11
12 Twin and Triple system Twin system: Super Digital Inverter 1-phase Twin system: Super Digital Inverter 3-phase type Compact 4-way cassette 4-way cassette Slim duct Standard duct Ceiling High wall Compact 4-way cassette 4-way cassette Slim duct Standard duct Ceiling High wall Outdoor unit (RAV-) (RAV-) HP Rated Cooling Capacity EER Heating Capacity COP min-max Power consumption 100% 80% 50% Rated min-max Power consumption 100% 80% 50% SP804AT(J)P-E SM404MUT-E SP1104AT(Z)(ZG)-E SM564MUT-E SP1104AT(Z)(ZG)-E SM564UTP-E SP1404AT(Z)(ZG)-E SM804UTP-E SP804AT(J)P-E SM404SDT-E SP1104AT(Z)(ZG)-E SM564SDT-E SP804AT(J)P-E SM406BTP-E SP1104AT(Z)(ZG)-E SM566BTP-E SP1404AT(Z)(ZG)-E SM806BTP-E SP1104AT(Z)(ZG)-E SM567CTP-E SP1404AT(Z)(ZG)-E SM807CTP-E SP1104AT(Z)(ZG)-E SM566KRT-E SP1404AT(Z)(ZG)-E SM806KRT-E SP1104AT8(Z)(ZG)-E SM564MUT-E SP1104AT7(Z)(ZG) SM564MUT-E SP1104AT8(Z)(ZG)-E SM564UTP-E SP1104AT7(Z)(ZG) SM564UTP-E SP1404AT8(Z)(ZG)-E SM804UTP-E SP1404AT7(Z)(ZG) SM804UTP-E SP1604AT8(Z)(ZG)-E SM804UTP-E SP1604AT7(Z)(ZG) SM804UTP-E SP1104AT8(Z)(ZG)-E SM564SDT-E SP1104AT7(Z)(ZG) SM564SDT-E SP1104AT8(Z)(ZG)-E SM566BTP-E SP1104AT7(Z)(ZG) SM566BTP-E SP1404AT8(Z)(ZG)-E SM806BTP-E SP1404AT7(Z)(ZG) SM806BTP-E SP1604AT8(Z)(ZG)-E SM806BTP-E SP1604AT7(Z)(ZG) SM806BTP-E SP1104AT8(Z)(ZG)-E SM567CTP-E SP1104AT7(Z)(ZG) SM567CTP-E SP1404AT8(Z)(ZG)-E SM807CTP-E SP1404AT7(Z)(ZG) SM807CTP-E SP1604AT8(Z)(ZG)-E SM807CTP-E SP1604AT7(Z)(ZG) SM807CTP-E SP1104AT8(Z)(ZG)-E SM566KRT-E SP1104AT7(Z)(ZG) SM566KRT-E SP1404AT8(Z)(ZG)-E SM806KRT-E SP1404AT7(Z)(ZG) SM806KRT-E SP1604AT8(Z)(ZG)-E SM806KRT-E SP1604AT7(Z)(ZG) SM806KRT-E Triple system: Super Digital Inverter 3-phase type Compact 4-way cassette 4-way cassette Slim duct Standard duct Ceiling High wall Outdoor unit (RAV-) (RAV-) HP Rated Cooling Capacity EER Heating Capacity COP min-max Power consumption 100% 80% 50% Rated min-max Power consumption 100% 80% 50% SP1604AT8(Z)(ZG)-E SM564MUT-E SP1604AT7(Z)(ZG) SM564MUT-E SP1604AT8(Z)(ZG)-E SM564UTP-E SP1604AT7(Z)(ZG) SM564UTP-E SP1604AT8(Z)(ZG)-E SM564SDT-E SP1604AT7(Z)(ZG) SM564SDT-E SP1604AT8(Z)(ZG)-E SM566BTP-E SP1604AT7(Z)(ZG) SM566BTP-E SP1604AT8(Z)(ZG)-E SM567CTP-E SP1604AT7(Z)(ZG) SM567CTP-E SP1604AT8(Z)(ZG)-E SM566KRT-E SP1604AT7(Z)(ZG) SM566KRT-E
13 Options TCB-FF101URE2 TCB-GFC1602UE 4-way cassette type Spacer for height adjustment Fresh air inlet box TCB-GB1602UE Air discharge direction kit TCB-BC1602UE RBC-U31PGP(W)-E RBC-U31PGP(WS)-E Spacer for height adjustment TCB-SP1602UE Panel RBC-U31PGP(W)-E RBC-U31PGP(WS)-E Air inlet grille Air discharge parts A Packing A Air discharge parts B Packing B Refrigerant piping side Drain piping side Air discharge parts C Packing B Standard duct type 694 TCB-SF56C6BPE TCB-SF80C6BPE TCB-SF160C6BPE Model TCB-SF56C6BPE TCB-SF80C6BPE TCB-SF160C6BPE Compatible (RAV-) SM406BTP-E, SM456BTP-E, SM566BTP-E SM806BTP-E SM1106BTP-E, SM1406BTP-E (Unit:mm) TCB-KP13CE, TCB-KP23CE Elbow piping Ceiling type RBC-AX33CE Wireless remote controller TCB-DP31CE Drain pump kit TCB-PCUC1E Optional connecting kit 13
14 Controllers & Accessories Parts Name Model Name Applied Model Remarks RBC-AMT32E Wired remote controller RBC-AMS41E RBC-AMS51E-ES/-EN Simple wired remote controller RBC-AS41E Controllers RBC-AX32U(W)/(WS)-E 4-way cassette Wireless remote controller kits RBC-AX33CE Ceiling TCB-AX32E2 TCB-EXS21TLE - Use with wired remote controller TCB-CC163TLE2 - Use with wired remote controller Remote controller kits TCB-SC642TLE2 BMS-CM1280TLE TCC-Link TCB-PCNT30TLE2 except High-wall Fresh air inlet box TCB-GB1602UE Use with TCB-GFC1602UE 4-way cassette Fresh air filter chamber TCB-GFC1602UE Auxiliary fresh air flange TCB-FF101URE2 4-way cassette, compact 4-way cassette and Slim duct Branch kit Accessories Application control Spacer for height adjustment TCB-SP1602UE 4-way cassette Air discharge direction kit TCB-BC1602UE 4-way cassette Drain pump kit TCB-DP31CE Ceiling Use with TCB-KP13CE, TCB-KP23CE TCB-KP13CE Ceiling Elbow piping kit TCB-KP23CE Ceiling Optional connecting kit TCB-PCUC1E Ceiling RBC-TWP30E2 Super Digital Inverter 1-phase, 3-phase model RBC-TWP50E2 RBC-TRP100E "1:3" Triple system of Super Digital Inverter 3-phase model TCB-PCOS1E2 Super Digital Inverter 1-phase model TCB-KBOS2E Features Inverter Features Allows step-less regulation of the air-conditioner s power,which reduces energy consumption and improves comfort. Applied Model Individual Louver control Enables airflows to be chosen according to user preferences. 4-way cassette Auto-turn Louver Air outlet grilles move automatically to fill every corner of the room with warm or cool air. except Slim duct and Standard duct Comfort Automatic Air Volume control Depending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low. Long-life Filter Built-in long-life filter makes maintenance easier. except High wall Hot Start When using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room. Dry Gradually dehumidifies the room to create even greater comfort. Filter Sign Automatic displays on the remote controller say when to perform maintenance for the indoor unit filter. except High wall Operativity Limit Timer On/Off Timer Uses a 168-hour timer with three modes - ON timer, OFF timer and Repeat OFF timer. The operation start and stop times can be set with a digital clock. except High wall High wall 20 minutes of fan operation after shut down 20 minutes of fan operation after shut down dries the moist air and helps reduce mold formation on heat exchanger coils. High wall Installation Cooler Compatible with an Outdoor Temperature of -15 C Built-in Drain Pump Stable cooler operation is possible when the outdoor temperature is as low as -15 C. The built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.) except High wall 14
15 Remote controllers Lite-Vision plus Remote Controller RBC-AMS51E-ES RBC-AMS51E-EN Wired remote controller with a built in 7-day timer-featuring a new multi-language, LCD display with backlight, energy saving options and a return back function. Possibility to set and display the room name to easily set-up and monitor the working parameter. New modern and desirable controller design with menu driven display. Save mode by schedule timer to optimise energy consumption. Room temperature display always available. Two Hot Keys (F1, F2) for easy operation of air conditioner functions. Easy to read layout including display of indoor unit model name and serial number. Built-in backup power. Settings are kept in memory up to 72 hours in case of power failure. Remote TA sensor available in controller. Can be connected to a single indoor unit or a group of up to 8 indoor units. RBC-AMT32E Standard Remote controller Standard wired remote controller can be connected to a single indoor unit or a group of up to 8 indoor units. Power save operation limits the greatest current value. The remote controller allows error to be displayed while the protective device works or a error occurs. RBC-AMS41E Remote controller with weekly timer (7-day timer function) Wired remote controller with clock display and a built in 7-day timer function, possible to program 8 functions for each day of the week. *The following items can be set in program: operation time, operation start/stop, operation mode, temperature setting, restriction on button operation TCB-SC642TLE2 Central remote controller Individual control for max. 64 indoor units divided into 1 to 4 zone (Up to 16 indoor units for each zone) Up to 16 outdoor header units are connectable 4 types of central control settings to inhibit individual operation by remote controller can be selected Usable with other central control devices (Max. 10 devices in one control circuit) Two control mode selectivity (Central controller mode ) Remote controller mode Setting of simultaneous ON/OFF 3 times per day combined with the weekly timer. BMS-CM1280TLE Central remote controller Operation Individual operation of 128 indoor units available Return Back Operation Weekly Schedule Operation* (ON/OFF) * Schedule timer necessary Monitoring Zone setting (64 zones x 2) Individual unit operation mode operation restriction Alarm display Control input Status output RBC-AS41E Simple wired remote controller Simple wired remote controller can be connected to a single indoor unit or a group of up to 8 indoor units. Start/Stop Temperature setting Air flow changing Check code display TCB-EXS21TLE Schedule timer Schedule timer mode 6 programmings per day Enabling 8 groups to be programmed A maximum of 64 indoor units can be controlled A maximum of 100 hours back-up power supply Weekly timer mode 7 types of weekly schedule and 3 programmings per day TCB-CC163TLE2 ON-OFF controller Individual control of up to 16 indoor units. Setting of simultaneous ON/OFF 3 times per day combined with the weekly timer. Wireless remote controller kit Start/Stop Changing mode Temperature setting Air flow changing Timer function Either ON time or OFF time or CYCLIC can be set how many 30 min. later ON or OFF is operated. Control by 2 remote controllers is available. Two wireless remote controllers can operate one indoor unit. The indoor unit can then be operated separately from the two different locations. Check code display RBC-AX32U(W)/(WS)-E Integral receiver (For 4-way cassette) RBC-AX33CE Integral receiver (For ceiling) TCB-AX32E2 Sensor unit; Stand alone receiver (For 4-way cassette, Compact 4-way cassette (600 x 600), Ceiling, Duct type, High wall) 15
16 Installation and the use of refrigerants not specified by Toshiba Carrier Corporation Toshiba refrigeration and air-conditioning units are designed and manufactured on the assumption that the product is used with a specific refrigerant suitable for each unit. We have recently seen some cases where the type of refrigerant used is different from the one originally installed in the product. Such actions may cause mechanical defects, malfunctions, failures and in some cases result in a serious safety issue. Therefore do not install any refrigerant other than the one specified by Toshiba Carrier Corporation for its respective products. The type of the refrigerant used for each of our products is shown in the accompanying owners manual, or on the product label attached on the product itself. Toshiba Carrier Corporation shall not assume any liability for failures, malfunctions or safety in its products if the refrigerant used is different from the one specified. SAFETY PRECAUTIONS For operation: Before use, read through the operating instructions to ensure proper use. Concerning the purpose for which the air conditioners are to be used The air conditioners presented in this catalogue are air conditioning/heating units to be used solely by general consumers. Do not use these air conditioners for special applications such as for the storage of food items, animals, plants, precision machines or works of art. Doing so may degrade the quality of the items. Do not use these air conditioners for air-conditioning applications in vehicles or ships. Doing so may cause water and/or power leakages. Precautions for using air conditioners Concerning the automatic defrosting unit When the outdoor air temperature drops, frost may form on the heat exchanger of the outdoor unit. In such cases, the automatic defrosting unit will be activated, and it will take 5 to 8 minutes for the heating operation to be restored. Concerning the air conditioner's operating conditions and their selection (1) Avoid using the air conditioner in the following locations. Locations with acidic or alkaline atmospheres (locations at which highly acidic or alkaline air is directly drawn in, such as in hot springs areas from which sulfur gases are given off, or where chemicals, vinegar, exhaust air from burners, etc., are given off) The heat exchangers and other parts may become corroded. Locations with atmospheres filled with coolant or other machine oil or steam exhaust (such as at food preparation factories or machine plants). The heat exchangers may corrode; frost may form as a result of heat exchanger malfunction; air conditioner operating performance may be compromised or condensation may form as a result of clogged filters; plastic parts may incur damage; heat-insulation materials may become separated, etc. (2) Before using an air conditioner in any of the following locations, consult with your dealer or a qualified contractor. Locations where vapors from edible oils are given off (such as in bakeries or kitchens and restaurants that use edible oils)...the air conditioner's operating performance may be compromised or condensation may form as a result of clogged filters, and the plastic parts may incur damage. In line with the prevailing conditions, take countermeasures such as tailoring the installation conditions in accordance with the conditions, using air conditioners designed for kitchens or oil guard filters, etc. Locations with disinfectant-induced chlorine atmospheres (water tanks, etc.) The metal parts in the heat exchangers, motors, etc., may become corroded. Locations with high salinity (coastal areas, etc.) Corrosion may occur so use outdoor units specifically designed to withstand exposure to salt. Locations where power is supplied from independent power generators. The power line frequency and/or voltage may fluctuate, possibly causing the air conditioner to malfunction. Locations where high frequencies or electrical noise is generated (from high-frequency welders used for vinyl welding and processing, high-frequency therapeutic devices used for thermotherapy, etc.) The electronic components may be adversely affected, possibly causing the air conditioner to malfunction. Locations where electronic equipment is installed. Electrical noise may adversely affect the operation of the electronic equipment. (3) Concerning use in locations with high ceilings In locations with high ceilings, use of circulators for improving the temperature distribution during heating is recommended. (4) Concerning use in high-humidity environments When the ceiling-recessed type of indoor unit is installed in a location, such as those described below, and it is very hot and humid inside the ceiling, condensation may form on the external surfaces of the indoor unit and drip down. In such cases, add external heat-insulating materials. Locations such as food preparation sites in which the areas above the ceilings are hot and humid Locations in which outside air is drawn in and routed above the ceiling Above ceilings with a slate roof or tiled roof overhead (5) Even when an air conditioner is shut down, it will still consume a small amount of power to protect the unit. If the air conditioner will not be used for a prolonged period, turn OFF the main switch (ground fault circuit breaker). However, before the unit is to be used again, turn ON the main switch (ground fault circuit breaker) for at least 12 hours in order to prevent trouble. Notice: - Products listed in this leaflet use HFC refrigerant R410A with a GWP of 2,088*. - Toshiba is committed to continuously improving its products to ensure the highest quality and reliability standards, and to meet local regulations and market requirements. All features and specifications are subject to change without prior notice. *The GWP value is calculated based on information provided in the EU F-gas Regulation and IPCC Fourth Assessment Report. T LC-SDI
for Light Commercial Use
Inverter Air Conditioning for Light Commercial Use 4 Toshiba's unique energy-efficient air conditioning innovations and technologies deliver high energy savings. Aluminum heat exchanger * High heat exchanger
More informationMiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL
MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL 2 Toshiba solutions residential, light commercial and larger commercial buildings. Residential indoor units are designed to blend perfectly with all interiors
More informationLight commercial range. Passion at work
Light commercial range Passion at work 2 Light Commercial Solutions for professionals, from professionals Toshiba-Carrier Super Digital Inverter systems deliver exceptional operating savings in extremely
More informationLIGHT COMMERCIAL RANGE Inverter heat pumps suitable for both homes and commercial premises
LIGHT COMMERCIAL RANGE Inverter heat pumps suitable for both homes and commercial premises Toshiba Heat Pumps. We care about better air. Toshiba was the first company to incorporate inverter technology
More informationInverter Air Conditioning for Light Commercial Use
Inverter Air Conditioning for Light Commercial Use 3 DI Digital Inverter Light Commercial The Toshiba Digital Inverter series air conditioners combine economy and ecology in a compact body They feature
More informationBlending Commercial and Residential. MiNi VRF
Blending Commercial and Residential MiNi VRF Toshiba Solutions Delivering Absolute Comfort Toshiba offers a solution for all applications: residential, light commercial and larger commercial buildings.
More informationInventor of the Inverter Digital Inverter System
Inventor of the Inverter Digital Inverter System Inventor of the Inverter The Digital inverter from Toshiba combines economy and ecology in a smart body. It offers state-of-the-art technology, exceptional
More informationLight commercial range. Passion at work. Light commer
Light commercial range Passion at work Light commer Index Introduction and technology 4 Outdoor unit 8 Indoor units and controls 10 Product pages Super Digital Inverter 4 outdoor unit 16 Super Digital
More informationTechnology that works fast. Inverter Ducted Systems
Technology that works fast Ducted Systems About Toshiba s Ducted systems. Combining high power with high efficiency. Toshiba s Ducted systems allows you to air The Toshiba Air Conditioning DC Hybrid. The
More informationTechnology that works fast. Inverter Ducted Systems
Technology that works fast Inverter Ducted Systems About Toshiba s Inverter Ducted systems. Toshiba s Inverter Ducted systems allows you to air condition your home without having to install the indoor
More informationTechnology that works fast. Inverter Ducted Systems
Technology that works fast Inverter Ducted Systems About Toshiba s Inverter Ducted systems. Toshiba s Inverter Ducted systems allows you to air condition your home without having to install the indoor
More informationIndex. Toshiba Solutions. Absolute comfort
2 3 Index Introduction 3 Industry leading energy savings 6 New smart & sensitive VRF control 10 Industry leading layout flexibility 14 Other features 18 Outdoor units Outdoor units line-up 20 Outdoor units
More informationINVERTER DUCTED SYSTEMS
INVERTER DUCTED SYSTEMS What you ll find inside: DC Twin-Rotary Compressor Inverter Ducted advantages Controllers Product Specifications Energy Efficient Powerful Operation Flexible Application 1 About
More informationProduct Launch SHRMi
Product Launch SHRMi What s SHRM i SMMS i (High Efficiency & Reliability) Simultaneous Operation by heat recovery + = SHRM i meets various customers needs! Refrigerant flow, cooling Liquid pipe Flow selector
More informationTOSHIBA AIR CONDITIONING
Digital Inverter Standard Specification R32 Introduction The following specification describes the Toshiba Digital Inverter Heat Pump air conditioning system(s) to be installed at the below site: (ADD
More informationBusiness. The business range. The most advanced solutions for larger buildings.
Business The business range The most advanced solutions for larger buildings. 81 82 Business VRF. The freedom of choice Variable refrigerant flow offer the advantages of direct expansion linked to inverter
More informationSimultaneous. Heating and Cooling Solution for Large Buildings. Air Conditioning for large buildings
Simultaneous Heating and Cooling Solution for Large Buildings Air Conditioning for large buildings Toshiba solutions Index Introduction 3 SHRM-e 4 Energy saving 6 Individual temperature control 8 Soft
More informationMiNi-SMMS Design Manual HFC R-410A. Indoor unit. Outdoor unit
Ref.-No. SMME06-111-10-06 MiNi-SMMS Design Manual Indoor unit 4-way ceiling cassette MMU-AP0091H, AP0121H, AP0151H, MMU-AP0181H, AP0241H, AP0271H, MMU-AP0301H, AP0361H, AP0481H Compact 4-way ceiling cassette
More informationAIR-CONDITIONER SPLIT TYPE
FILE. A07-003 Revised:Mar., 2008 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE INDOOR UNIT RAV-SM564UT-E RAV-SM804UT-E RAV-SM04UT-E RAV-SM404UT-E OUTDOOR UNIT RAV-SP404AT-E
More informationV ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.
HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless
More informationCompact 4-way Cassette ( ) Type
E08-0 Engineering Data Compact 4-way Cassette (600 600) Type Indoor Unit RAV-SM40MUT-E RAV-SM4MUT-E Outdoor Unit RAV-SP404AT-E RAV-SP44AT-E Contents. Specifications. Connecting pipe length and lift difference
More informationexcellence in seasonal efficiency BUSINESS SOLUTIONS
excellence in seasonal efficiency BUSINESS SOLUTIONS EXCELLENCE in SEASONAL efficiency 8-10 HP The Toshiba SHRM-e, for A whole range of innovations The new Toshiba SHRM-e puts the emphasis on evolution
More informationInverter Ducted Air Conditioners
Inverter Ducted Air Conditioners About Carrier Inverter Ducted Systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making
More informationEnergy-saving operation
DC Inverter can attain both comfort a Energy-saving operation All the models of Panasonic FS Inverter Series are equipped with DC inverters for the higher EER operation. The new design attains quiet and
More informationAir Conditioning For Large Buildings
Air Conditioning For Large Buildings Index Introduction 2 Line-up 16 Outdoor SMMS-i specifications 20 Indoor 4-way cassette 22 Compact 4-way cassette 24 2-way Air Discharge Cassette Type 26 1-way cassette
More informationHigh Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.
HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy
More informationInverter Wall Mounted Series
PCXRY14 Inverter Wall Mounted Series R410A Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. 2014-09 Printed In Malaysia
More informationSingle Fan MiNi VRF Apartment Ready
SINGLE FAN MiNi VRF What you ll find inside: Technology Features Controllers Product specifications Single Phase Energy efficient Heating & cooling Single Fan MiNi VRF Apartment Ready SINGLE FAN MiNi VRF
More informationMidea Ducted and Cassette Split Systems. Maximum versatility, maximum value.
Midea Ducted and Cassette Split Systems Maximum versatility, maximum value. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.
More informationTechnical Guide. Multizone: Multi-Split Type Heat Pump Systems
Technical Guide Multizone: Multi-Split Type Heat Pump Systems 1 Another Hitachi Day 1 Wall Mounted (RAK) Imagine choosing your perfect day then instantly creating it in the comfort of your own home. With
More informationAir to water Heat Pump System
Air to water Heat Pump System 2 The heating and cooling systems of the future! A step in the right direction of reducing pollution and CO₂ emissions The increase of CO₂ and other green house gases is a
More informationDC Inverter Smart VRF Products(R410A)
DC Inverter Smart VRF Products(R410A) General Description What is DC Inverter Smart? Inverter Smart system is YDS system: 1. With DC inverter compressor; 2. Condensing unit and heat pump type; 3. It is
More informationMRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design
Special Heat Exchanger Design 4 way air return heat exchanger design Reduce the heat exchanger height (6mm), and the upper and lower wind speed uniform and high efficiency. Air Supply Chamber and Equipment
More informationDESIGN MANUAL R410A. Indoor Unit. Outdoor Unit FILE NO. A Cooling Only Model <Inverter Unit> Heat Pump Model <Inverter Unit>
FILE NO. A03-008 DESIGN MANUAL R410A Indoor Unit MMU-AP0091H, AP0121H, AP0151H, MMU-AP0181H, AP0241H, AP0271H, MMU-AP0301H, AP0361H, AP0481H MMU-AP0561H
More informationCommercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF
2016 Commercial Air Conditioners VRF 60Hz V4+SV4+RV4+WMini VRF OUTDOOR UNIT LINEUP INDOOR UNIT LINEUP 1.8 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 20.0 25.0 28.0 40.0 45.0 OUTDOOR UNIT
More informationMidea Ducted and Cassette Split Systems. Year round comfort, all around the house.
Midea Ducted and Cassette Split Systems Year round comfort, all around the house. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.
More informationCommercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series
Commercial Air Conditioners 2017/2018 VRF 50/60Hz V5 X Series Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and
More informationSuper Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit
Ref.-No. SMMS02-AE-10-05 Indoor unit 4-way ceiling cassette MMU-AP0091H, AP0121H, AP0151H, MMU-AP0181H, AP0241H, AP0271H, MMU-AP0301H, AP0361H, AP0481H MMU-AP0561H 2-way ceiling cassette MMU-AP0071WH,
More informationEngineering Data Book
E10-331 Engineering Data Book 3 compressors & 3 inverters Super Modular Multi System < Digest version > Notice: Toshiba is committed to continuously improving its products to ensure the highest quality
More informationCome home to a warm welcome
JULY 2011 Ducted Come home to a warm welcome New Zealand s favourite home improvement Fujitsu adds ultimate comfort to your home. Fast, effective heating keeps you warm as toast in winter (even when it
More informationAIR-CONDITIONER SERVICE MANUAL SPLIT TYPE R410A OUTDOOR UNIT
FILE. A09-004 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE OUTDOOR UNIT RAV-SM2244AT8-E RAV-SM2804AT8-E RAV-SM2244AT8Z-E RAV-SM2804AT8Z-E RAV-SM2244AT8ZG-E RAV-SM2804AT8ZG-E RAV-SM2244AT7
More informationMiraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.
MISR REFRIGERATION & AIR CONDITIONING MFG. CO. COOL EER HEAT COP 0V ~ 50Hz 1Ph Inverter High Wall Split Systems For Energy Saving Heat Pump 1K - 18K - 4K DC Inverter R-410A Inverter Technology R-410A HFC
More informationVariable Refrigerant Flow
Variable Refrigerant Flow Two-pipe Heat Recovery and Heat Pump Systems Heat Recovery Single-chassis Design Heat Pump Modular Design Table of Contents Carrier VRF Advantages 2 Revolutionary Design 3 Advanced
More informationSMC DUCTED. High Performance AIR CONDITIONING SYSTEMS
SMC DUCTED High Performance AIR CONDITIONING SYSTEMS NEW SLIM DUCTED SYSTEM h 220 mm 1 Slim and compact The new SMC Ducted system is just 220mm in height for sizes up to 5.94 kw and 310mm for larger systems,
More informationInverter Ducted Air Conditioners
Inverter Ducted Air Conditioners About Carrier inverter ducted systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making
More informationwe care about Better Air
3 Technologies & Useful Features INVERTER G2KCV Toshiba IAQ Pre-filter Filters Toshiba Airconditioning, we care about Better Air Our products comply with RoHS Regulations, ensuring no restricted substances
More informationWhole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.
Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair become
More informationWhole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.
Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair become
More informationP-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP
P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP www.mitsubishielectric.ca P-SERIES The Attraction of Being Untraditional Mr. Slim P-Series is the ductless solution for demanding environments that
More informationDuctless Systems. Right product for the right application
Ductless Systems Right product for the right application Right Product for the Right Application Single-Zone Multi-Zone Light Commercial RAS System High Wall (Up to 23 SEER) RAV-**KRT System High Wall
More informationOwner s Manual VN-M150HE VN-M250HE VN-M350HE VN-M500HE VN-M650HE VN-M800HE VN-M1000HE VN-M1500HE VN-M2000HE. Air to Air Heat Exchanger
Air to Air Exchanger Owner s Manual Concealed Microcomputer Control Type l name: M150 M250 M350 M500 M650 M800 M1000 M1500 M2000 For commercial use Owner s Manual English Air to Air Exchanger Owner s Manual
More informationComfort. Health Clean. Saving. The new era in air conditioning. Multi-Split Systems
Health Clean Comfort Better Saving air The new era in air conditioning Multi-Split Systems MULTI Toshiba Multi-Split System Luxury through flexibility & technology Toshiba s Multi-Split System will deliver
More informationVARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG
VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG Spring 2017 Edition BRYANT VRF ADVANTAGES IT TAKES an Efficient Solution...1 What is Variable Refrigerant Flow (VRF)...1 Simultaneous Heating & Cooling...1
More informationRC-0219-A. Single-Split Non Inverter Series
TM RC-0219-A Single-Split Non Inverter Series R32 The Superior Refrigerant This game changing refrigerant strikes the perfect balance between energy efficiency, ease of use and environmental sustainability;
More information(Non-Inverter & Inverter) R410A
LG Commercial Air Conditioner Sinlge Split Type (Non-Inverter & Inverter) R410A Distributed by LG Electronics www.lg.com http://partner.lge.com Copyright 2015 LG Electronics. All rights reserved. Non-Inverter
More informationLaunching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-
Suary PAGE: 1 / 47 1 This Technical Bulletin introduces the new outdoor units of the SET-FREE FSXN1E Series (8 to 54HP) using R410A. 2 The details are indicated in the description. Index 1. Main concepts...
More informationDucted Air Conditioning
Ducted Air Conditioning Why Choose Mitsubishi Electric? Whether it is consistent heating and cooling for the home or office, Mitsubishi Electric offers you state-of-the-art technology that is quiet, simple
More informationAir to water Heat Pump System
Air to water Heat Pump System 2 The heating and cooling systems of the future! A step in the right direction of reducing pollution and CO₂ emissions The increase of CO₂ and other green house gases is a
More information-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.
WALL-MOUNTED HEAT PUMPS SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) UP TO 23 SEER UP TO 11 HSPF HEATING UP TO -20 C 10 years* *See details on the back Warranty Exclusive distributor in Quebec descair.ca What
More informationWhole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.
Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 198 saw Advanced Australia Fair become
More informationDucted Air Conditioning
Ducted Air Conditioning Why Choose Mitsubishi Electric? Whether it is consistent heating and cooling for the home or office, Mitsubishi Electric offers you state-of-the-art technology that is quiet, simple
More informationUltimate VRF System R410A, 50Hz
Ultimate VRF System R410A, 50Hz TVR WIZ Systems, a new leap in technology and innovation A proven solution from a trusted advisor Trane is proud to present their new line of variable refrigerant systems,
More informationComfort. Health Clean. Saving. The new era in air conditioning. Multi-Split Systems
Health Clean Comfort Better Saving air The new era in air conditioning Multi-Split Systems Technology in Multi-Split Systems When it is necessary to provide total comfort solution for a multi-room application,
More informationEREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY
Easy and fast installation Hydronic module available Compact, reliable and efficient Nominal cooling capacity : 8-40 kw Nominal heating capacity : 17-40 kw 50 410A Cooling or heating USE The air-to-water
More informationDC inverter Outdoor-air Processing unit (GC )
DC inverter Outdoor-air Processing unit (GC201109- ) ER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTERNDITINER TECHNICAL SALES GUIDE-50Hz CAPACITY RANGE:14~56kW
More informationDESIGN MANUAL R410A. Outdoor Unit. FS unit FILE NO. A RBM-Y1122FE RBM-Y1802FE RBM-Y2802FE
FILE NO. A04-017 DESIGN MANUAL R410A Heat Recovery Type Indoor Unit MMU-AP0091H, AP0121H, AP0151H, MMU-AP0181H, AP0241H, AP0271H, MMU-AP0301H, AP0361H, AP0481H MMU-AP0561H
More informationPRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL
PRODUCT LINEUP VRF For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL 100 AIRSTAGE VRF Systems can be designed to create an air conditioning solution to suit most building requirements. AIRSTAGE VRF Systems
More informationTOSHIBA Carrier (UK) Ltd. LC DX Interface Installation manual ENGLISH. For commercial use. Model name:
TOSHIBA Carrier (UK) Ltd. LC DX Interface Installation manual Model name: For commercial use RAV-DXC010 LC DX Interface ENGLISH Please read this carefully before installing the LC DX interface. This Manual
More informationturn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES
turn to the experts SM R 410A DC INVERTER LIGHT COMMERCIAL SERIES DC Inverter Technology More Economical Energy Efficient Once indoor air temperatures reach your desired levels, inverter driven air-conditioners
More informationMRVIII-S. 007 Features & Benefits 017 MRVIII-S Outdoor
1 7 Features & Benefits 17 Outdoor 5 6 (SIDE DISCHARGE) OUTDOOR STRUCTURE (/1/12HP SIDE DISCHARGE) More Bigger Outdoor Capacity, More Flexible Application High efficiency DC fan motor Vector inverter control
More informationToshiba solutions 3 At Toshiba, we believe that Evolu on is leading the path to a be er future. Through the decades, we have been constantly crea ng i
Toshiba solutions 3 At Toshiba, we believe that Evolu on is leading the path to a be er future. Through the decades, we have been constantly crea ng innova ve and high-quality electrical appliances to
More informationLeading edge reverse cycle air conditioning. Ducted and ceiling cassette
Leading edge reverse cycle air conditioning Ducted and ceiling cassette Seeley International never stops striving to innovate and build the world s most energy efficient heaters and air conditioners. The
More informationInverter console UFV system. Compact design and personalised air flow selection
Inverter console UFV system Compact design and personalised air flow selection 2 Efficient and reliable system Thanks to Toshiba DC Hybrid Inverter technology the system operates at maximum capacity in
More informationDAIKIN Modular Inverter Air Cooled Chiller
DAIKIN Modular Inverter Air Cooled Chiller R410A ODP=0 R410A ODP=0 R410A ODP=0 R410A ODP=0 1 EVOLUTION ULTIMATE DAIKIN has achieved a wealth of world s firsts over the last three centuries. Based on four
More informationSplit Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]
PCRHK1543 Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical
More information2 &3-4 Head Multi System
2 &3-4 Head Multi System INVERTER 2 &3-4 ROOM Multi System The Fujitsu Inverter Multi System has been designed with flexibility in mind. With the introduction of indoor units in a range of capacities and
More informationSubmittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System
Submittal Data: Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationELECTRICAL QUANTITY WEIGHT (LB)
VRF SYSTEM INDOOR UNIT ENTERING AIR TEMPERATURES ( F) CAPACITIES (kbtuh) Max SOUND ELECTRICAL WEIGHT TOSHIBA-CARRIER COOLING HEATING Airflow PRESSURE, MARK NO. TYPE ROOM TOTAL SENSIBLE HEATING V / Ø /
More informationTechnical HandBook. Version
Technical HandBook 24 Hour Technical Helpline: 0870 843 0333 Fault & DN Code Apps: Android & iphone Web Page toshiba calc.co.uk/fault codes/ Fault Code Text Service: 07624 803 017 technical.enquiries@toshiba-ac.com
More informationHi - Wall Split Systems 12K - 18K - 24K
R22 220-240V ~ 50Hz 1Ph Hi - Wall Split Systems 12K - 18K - 24K Technology Tropical Compressor Super Quiet Auto Auto Fan Speed Auto Restart Function Self diagnostic function Active Carbon Electrostatic
More informationInventor of the Inverter
Inventor of the Inverter MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL COST SAVING INSTALLATION R410A HIGH EFFICIENCY HIGH RELIABILITY QUIET OPERATION SMALL AND LIGHTWEIGHT Model Type Model Name Capacity
More informationSlim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump
0-40V ~ 0Hz Ph 80-40V ~ 0Hz Ph Slim Line Ceiling Concealed Ducted Split Systems Green Medium Static Pressure Ducted Split System Heat Pump - 8-4 - 0 - - 48-0 DC Inverter Inverter Technology $ Efficient
More information15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)
Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -Medium Static Pressure Capability -Return
More information360 round flow, ensuring uniform airflow distribution across the room. Independent louvre control allows each louvre to be set at the desired angle
AUTO ILLE ELEVATION GR ED CAN BE LOWER UP TO 4M Better Design Super slim design, perfect for tight roof spaces 360 round flow, ensuring uniform airflow distribution across the room Independent louvre control
More informationCompact design & easy maintenance
Compact design & easy maintenance 18 SEER MRCOOL Address: 1315 College Street Clarksville TN 37040 Email: sales@mrcool.com mrcool.com Specifications and appearance are subject to change without notice.
More informationSKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR
SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR Comfort We offer a wide range of products, and always provide you with
More informationSubmittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To
Submittal Data: Innovative Ductless solutions 12,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationSubmittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System
Submittal Data: Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Compact and Quiet Design -High Efficiency DC Inverter Technology -Wireless Remote
More informationDaikin MXS SERIES MULTI-ZONE HEATING & COOLING SYSTEMS
Daikin MXS SERIES MULTI-ZONE HEATING & COOLING SYSTEMS 1.5-3 TON, 2-4 ZONE SYSTEMS UP TO 18.9 SEER / UP TO 12.5 HSPF / UP TO 12.7 EER VARIABLE-SPEED COMPRESSOR RESIDENTIAL AND LIGHT COMMERCIAL APPLICATIONS
More informationCompact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design
VRF system for medium sized buildings SMALL OFFICES Compact Design For Light Commercial Buildings Perfect total air conditioning systems with features of energy saving, low noise, comfortable airflow,
More informationSubmittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To
Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless
More informationVRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group
VRF D4 PLUS System Digital Scroll Series GD Midea Heating & Ventilating Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 GD Midea Heating
More information15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)
Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless
More information. Creating Maximum Comfort
P P r o d u c t E X P L A N A T I O N M M a i n F E A T U R E S AA. Creating Maximum Comfort 1 Inverter technology The linear VRV system makes use of a variable Proportional Integral (PI) control system
More informationInnovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date
Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI 24,000 BTUH 24,000 Ceiling BTU/H Cassette Ceiling Heat Casse3e Pump Heat System Pump System Job Name Location Date Purchaser
More informationSubmittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To
Submittal Data: Innovative Ductless solutions 24,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationFUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION
FUJITSU VRF PRODUCT CATALOGUE 2016/17 VRF VENTILATION SPLIT MULTI SPLIT VRF VENTILATION SUPPORT Design Simulator Automatically create model selection information Each unit can be automatically set by entering
More informationDAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER
DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER FHQ SERIES HEAT PUMP AND COOLING ONLY SYSTEMS CEILING-SUSPENDED CASSETTE Up
More informationA GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA
A GUIDE TO COMFORT HITACHI INVERTER SPLIT SYSTEMS Enjoy the Silence with Quiet Mode With Hitachi, noisy air conditioners are a thing of the past. Our modern Full Flat design has ensured efficient yet ultra-quiet
More informationCarrier. Ductless Systems. Taking Comfort, And Your Business, Further. The Right Solution. Right Now.
Carrier Ductless s. Taking Comfort, And Your Business, Further. The Right Solution. Right Now. Spring 2016 Carrier Can Take You Further With Carrier Ductless systems, there are even more innovative and
More information