Toshiba solutions 3 At Toshiba, we believe that Evolu on is leading the path to a be er future. Through the decades, we have been constantly crea ng i

Size: px
Start display at page:

Download "Toshiba solutions 3 At Toshiba, we believe that Evolu on is leading the path to a be er future. Through the decades, we have been constantly crea ng i"

Transcription

1

2 Toshiba solutions 3 At Toshiba, we believe that Evolu on is leading the path to a be er future. Through the decades, we have been constantly crea ng innova ve and high-quality electrical appliances to increase our consumers sa sfac on. Now, with Toshiba "SMMS-e", the latest commercial air condi oning for various buildings, The SMMS-e has been crea vely developed and designed under the concept Excellence, Expansion, and Experience to ensure your utmost comfort and convenience like never before. With the latest technology improved and developed to make SMMS-e the top commercial air condi oning for any solu on that intelligently meets your needs, Toshiba will stop at nothing to create innova on to evolu on of the future, where life is a step away from perfec on.

3

4 4

5 5

6 XPANSION

7 9 XPERIENCE XCELLENCE

8 8 PRODUCT RELIABILITY LINE UP Space saving model Equivalent HP 8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP High efficiency/high diversity model Equivalent HP 14HP 18HP Product line up 8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP 24HP 26HP 28HP 30HP 32HP 34HP 36HP 38HP 40HP 42HP 44HP 46HP 48HP 50HP 52HP 54HP 56HP 58HP 60HP Space saving model High efficiency /High diversity model

9 9 ENERGY SAVING Greater efficiency performance Adop ng the highly e cient new DC twin-rotary compressors with various technologies % load EER 50% load HP 10HP 12HP 14HP 16HP 18HP *Conditions: Cooling: Indoor air temperature 27 C DB/19 C WB, outdoor air temperature 35 C DB *High efficiency/high diversity model by single outdoor unit

10 10 DIVERSITY RELIABILITY Greater diversity Thanks to the newly developed refrigerant circuit, the diversity of outdoor units has dras cally increased. This makes it much easier to design for installa ons with many rooms or o ces. High efficiency model/high diversity model SMMS-e Current 8HP diversity up to SMMS-e (8HP) 170% 8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP 24HP 26HP 28HP 30HP 32HP 34HP 36HP 38HP 40HP 42HP 44HP 46HP 48HP 50HP 52HP 54HP 56HP 58HP 60HP 170% 150% 135% 145% 135% 150% 150% 140% 135% 140% 145% 140% 135% 140% 135% 140% 140% 145% 140% 140% 135% 140% 135% 145% 140% 135% 135% 135%

11 11 PREVENT SMALL ANIMALS Prevent small animals getting into the inverter To prevent the small animals from entering and interfering with the electronic components in the system, our new inverter box has been upgraded with addi onal protec on, while allowing reliable opera on. The inverter box is ed with punched sheet metal & resin sheet Seal wiring holes 2 with resin sheet The diameter of each punched sheet metal is 4mm *This is applicable for small animals bigger than 4mm.

12 12 CAPACITY RELIABILITY RANGE Single unit capacity expanded SMMS-e comes with 3 new larger capacity units, producing up to 22HP on a single module pla orm. New HP HP HP Industry-leading installation flexibility *Space saving model Outdoor units improve performance to achieve greater space e ciency that de es their compact module size to deliver greater freedom in layout design. This minimizes weight-related restric ons and allows for quicker installa on. 22HP 26HP Previous model 10HP 12HP 10HP 8HP 8HP 1,980 mm 2,970 mm SMMS-e 22HP 14HP 12HP Free Space 1,600 mm 1,980 mm

13 13 System capacity expanded With the SMMS-e, it is now possible to connect up to 60HP in one system, with up to 64 connectable indoor units. Previous model SMMS-e While expanding the maximum combina on from 48 to 60HP in one system. This helps save more me and expense on addi onal unit system required in the previous model. The new compact unit design also increases more exibility on installa on with less foot print. Previous model SMMS-e SMMS-e is capable of covering up to 22HP with a single module. Reducing pipe work and overall installa on me.

14 14 RELIABILITY SMMS WAVE TOOL SMMS wave tool With SMMS wave Tool, you can read and write data from outdoor unit directly on your smart phone without the needs of connec ng PC or opening cabinet. By the new smart phone applica on, the tes ng and commissioning can be done without opening the cabinet. Previous model SMMS-e

15 15 Available data Whether the product data, system data, fault history or tes ng and commissioning, all can be obtained easily even in case of under service maintenance or power failure. The data can be easily sent to the distant o ce via . Possible to receive system data by without moving from your o ce and the opera on condi ons can be checked in the o ce. In case of below situation Installation Service maintenance Power failure System data Product data Available data Fault history Test operation result Smart phone The Site The

16 16 DC RELIABILITY TWIN-ROTARY COMPRESSOR Wide range compressor More powerful and e cient with the cu ng-edge technology of compressor DC Twin-Rotary operates in wider range of rota on speed. Previous Displacement volume 42 cm 3 SMMS-e Displacement volume x1.5 Displacement volume 64 cm 3 DLC coated vane Increased hardness of the DLC coated vane reduces fric on and increase both reliability and performance. DLC Coat vane Rotary shaft roller Crank DLC Coat vane Cylinder * DLC: Diamond Like Carbon 2-stage vane With 2-stage vane innova vely designed to reduce fric on while increasing hardness s and enhancing performance at its best. Contact portions 1stage vane Contact portions 2stage vane 1 stage Previous SMMS-e Shaft Shaft 2 stage

17 17 HEAT EXCHANGER New heat exchanger New heat exchanger of SMMS-e increases from 2 to 3 rows, providing even more surface area of the total pipe up to 13%. SMMS-e Previous model heat exchanger SMMS-e new heat exchanger HP Previous model SMMS-e Increased the surface area of the total pipe Variable heat exchanger New system controls allows the outdoor unit to select the most e cient heat exchanger size, which matches the capacity load in order to provide higher energy savings. Use Max. operation of the total capacity Nonuse Min. operation of the total capacity Use Use Ex. Cooling operation in high out door temp. Ex. Cooling operation in high out door temp. Heat exchangers are located on all four sides of the outdoor unit, ensuring air ow is equal in all direc ons. Machine room w heat exchanger SMMS-e

18 18 PIPING DESIGN FLEXIBILITY RELIABILITY Total piping length Even more convenient with the piping distance from the rst branch to the furthest indoor unit at 90 meters, increasing the exibility of the installa on within the hotel or o ce building. Applied with Toshiba s unique and greatly improved technology, SMMS-e can reach up to 1,000 meters maximum piping length. Total piping length SMMS-e Max. total length Fartthest pipe Farthest fro st branch Farthest equivalent length Height between ween indoor units The maximum equivalent distance between outdoor unit and farthest indoor unit tops at 235 meters, which tops the industry class. Another industry s top class is a maximum ver cal distance between indoor units nits which reaches up to 40 meters, equal to an en re 11-storied ried building. SMMS-e s enhanced piping capabili es result in n more bene ts for the system design, installa on exibility, ty, as well as the less installa on cost. m Farthest equivalent length Heig between Height indoor unit indo

19 19 Piping capabilities summary Piping capability can provide more bene ts for the system design, the installa on exibility, and the installa on cost. 11F 10F 9F 8F 7F 6F 5F 4F 3F 2F 1F F 10F 9F 8F 7F 6F 5F 4F 3F 2F 1F 4 3 Total length 1,000m* 1. Farthest equivalent length 235m 2. Farthest pipe from 1 st branch 90m** 3. Height between outdoor unit - indoor unit 90m*** / ( outdoor unit above/below ) 40m 4. Height between indoor unit - indoor unit 40m * : 34HP combina on or more ** : 65m if the height piping length between outdoor unit and indoor unit is more than 3m *** : Be sure to refer to the Engineering Data Book for details of these condi ons and requirements.

20 20 SLIMMER RELIABILITY PIPE SIZE Piping saving costs With the sub-cool heat exchanger less refrigerant is needed therefore now it is possible to use smaller pipes and save in installa on costs. NEW SMMS-e φ 28.6 mm Previous model φ 34.9 mm One size down 22 HP Sub-cool heat exchanger available in all models

21 21

22 22 RELIABILITY Backup operation In case of a compressor failure, SMMS-e can keep working with the backup opera on under All Inverter Control to compensate a failed compressor or header unit. This backup opera on is available in both a single system or as a module. Single outdoor unit backup Module outdoor unit backup Failed compressor Failed outdoor unit Reliability rotational control The rota onal control in SMMS-e is designed to improve system reliability by controlling the opera on of each compressor to work equally under variable condi ons. 80% 30% Outdoor temp rise Noon Outdoor temp down Comp1/Comp2 Morning Evening Increase Air-conditionning load Decrease Air-conditionning load Comp1/Comp2 Comp1/Comp2

23 23 OPERATING TEMPERATURE RANGE Outdoor temperature range U lizing the newly designed compressor, SMMS-e can operate under the wider range of outdoor ambience with the expansion of cooling from -5 C to 46 C. Operation ambient temperature expansion (Cooling : CDB,Heating : CWB) Cooling ( C ) ( C) Note : Based on equivalent piping length of 7.5 m and piping height di erence of 0 m. The external static pressure The SMMS-e units are suitable for challenging installa ons where high external sta c pressure performance 60 pa Air flow simulation diagram 7F 6F 5F 4F 3F 2F Note : This result is analy cal simula on, that does not guarantee actual temperatures.

24 24 Outdoor units Space saving model 8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP MAP0806T8P-SG MAP1006T8P-SG MAP1206T8P-SG MAP14B6T8P-SG MAP1606T8P-SG MAP18B6T8P-SG MAP2006T8P-SG MAP2206T8P-SG HP 26HP 28HP 30HP 32HP 34HP 36HP 38HP AP2416T8P-SG AP2616T8P-SG AP2816T8P-SG AP3016T8P-SG AP3216T8P-SG AP3416T8P-SG AP3616T8P-SG AP3816T8P-SG MAP1206T8P-SG MAP1206T8P-SG MAP14B6T8P-SG MAP1206T8P-SG MAP14B6T8P-SG MAP14B6T8P-SG MAP1606T8P-SG MAP14B6T8P-SG MAP1606T8P-SG MAP1606T8P-SG MAP18B6T8P-SG MAP1606T8P-SG MAP18B6T8P-SG MAP18B6T8P-SG MAP2206T8P-SG MAP1606T8P-SG HP 42HP 44HP 46HP 48HP AP4016T8P-SG AP4216T8P-SG AP4416T8P-SG AP4616T8P-SG AP4816T8P-SG MAP2206T8P-SG MAP18B6T8P-SG MAP2206T8P-SG MAP2006T8P-SG MAP2206T8P-SG MAP2206T8P-SG MAP1606T8P-SG MAP1606T8P-SG MAP14B6T8P-SG MAP1606T8P-SG MAP1606T8P-SG MAP1606T8P-SG HP 52HP 54HP 56HP 58HP 60HP AP5016T8P-SG AP5216T8P-SG AP5416T8P-SG AP5616T8P-SG AP5816T8P-SG AP6016T8P-SG MAP18B6T8P-SG MAP1606T8P-SG MAP1606T8P-SG MAP18B6T8P-SG MAP18B6T8P-SG MAP1606T8P-SG MAP18B6T8P-SG MAP18B6T8P-SG MAP18B6T8P-SG MAP2006T8P-SG MAP18B6T8P-SG MAP18B6T8P-SG MAP2206T8P-SG MAP18B6T8P-SG MAP18B6T8P-SG MAP2206T8P-SG MAP2206T8P-SG MAP1606T8P-SG

25

26 26 Recommended isolator (A) Individual isolator is recommended for each outdoor unit Recommended isolator (A) Individual isolator is recommended for each outdoor unit

27 27 Space saving model (Combination) Equivalent HP Model name 50Hz MMY- AP2416T8P-SG AP2616T8P-SG AP2816T8P-SG 24HP Outdoor unit type Inverter Power supply (* 1 ) 3phase 4wires 50Hz 400V ( V) Outdoor unit model 50Hz MMY- MAP1206T8P-SG MAP1206T8P-SG MAP14B6T8P-SG MAP1206T8P-SG MAP14B6T8P-SG MAP14B6T8P-SG Capacity 100% (kw) Power consumption (kw) Starting current Soft start Soft start Soft start Running current (A) Cooling (* 2 ) EER Capacity 100% Capacity 50% Total weight (kg) Compressor Motor output ( kw) 3.9 x x x x x x 2 Fan unit Motor output (kw) Air volume (m 3 /h) 12,200 12,200 12,200 12,200 12,200 12,200 Gas side (mm) ø 34.9 ø 34.9 ø 34.9 Refrigerant Main pipe diameter Liquid side (mm) ø 19.1 ø 19.1 ø 19.1 piping Balance pipe (mm) ø 9.5 ø 9.5 ø 9. 5 Sound pressure level Diversity (db(a)) % % % 26HP 28HP cations Equivalent HP Model name 50Hz MMY- AP3016T8P-SG AP3216T8P-SG 30HP Space saving model (Combination) Outdoor unit type Inverter Power supply (* 1 ) 3phase 4wires 50Hz 400V ( V) Outdoor unit model 50Hz MMY- MAP1606T8P-SG MAP14B6T8P-SG MAP1606T8P-SG MAP1606T8P-SG MAP18B6T8P-SG MAP1606T8P-SG Capacity 100% (kw) Power consumption (kw) Starting current Soft start Soft start Soft start Running current (A) Cooling (* 2 ) EER Capacity 100% Capacity 50% Total weight (kg) Compressor Motor output (kw) 5.8 x x x x x x 2 Fan unit Motor output ( kw) Air volume (m 3 /h) 12,600 12,200 12,600 12,600 12,600 12,600 Gas side (mm) ø 34.9 ø 34.9 ø Refrigerant Main pipe diameter Liquid side (mm) ø 19.1 ø 19.1 ø piping Balance pipe mm) ø 9.5 ø 9.5 ø 9. 5 Sound pressure level (db(a)) Diversity 130% 135% 130% 32HP 34HP AP3416T8P-SG *1 *2 Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB

28 28 Space saving model (Combination) Equivalent HP 36HP Model name 50Hz MMY- AP3616T8P-SG AP3816T8P-SG AP4016T8P-SG Outdoor unit type Inverter Power supply (* 1 ) 3phase 4wires 50Hz 400V ( V) Outdoor unit model 50Hz MMY- MAP18B6T8P-SG MAP18B6T8P-SG MAP2206T8P-SG MAP1606T8P-SG MAP2206T8P-SG MAP18B6T8P-SG Capacity 100% (kw) Power consumption (kw) Cooling (* 2 ) Starting current Soft start Soft start Soft start Running current (A) EER Capacity 100% Capacity 50% Total weight Compressor Motor output (kw) 6.9 x x Fan unit Motor output (kw) Air volume (m 3 /h) 12,600 12,600 18,500 12,600 18,500 12,600 Gas side (mm) ø 41.3 ø 41.3 ø Refrigerant Main pipe diameter Liquid side (mm) ø 22.2 ø 22.2 ø piping Balance pipe (mm) ø 9.5 ø 9.5 ø 9. 5 Sound pressure level (db(a)) Diversity 130% 135% 130% 38HP 40HP cations Equivalent HP 42HP 46HP Space saving model (Combination) Model name 50Hz MMY- AP4216T8P-SG AP4416T8P-SG AP4616T8P-SG AP4816T8P-SG Outdoor unit type Inverter Power supply (* 1 ) 3phase 4wires 50Hz 400V ( V) Outdoor unit model 50Hz MMY- MAP2206T8P-SG MAP2006T8P-SG MAP2206T8P-SG MAP2206T8P-SG MAP1606T8P-SG MAP1606T8P-SG MAP14B6T8P-SG MAP1606T8P-SG MAP1606T8P-SG MAP1606T8P-SG Capacity 100% (kw) Cooling (* 2 ) Power consumption (kw) Starting current Soft start Soft start Soft start Soft start Running current (A) EER Capacity 100% Capacity 50% Total weight (kg) Compressor Motor output (kw) x x2 5.4 x x x x 2 Fan unit Motor output (kw) Air volume (m 3 /h) 18,500 17,900 18,500 18, Gas side (mm) ø 41.3 ø 41.3 ø 41.3 ø Refrigerant Main pipe diameter Liquid side (mm) ø 22.2 ø 22.2 ø 22.2 ø piping Balance pipe (mm) ø 9.5 ø 9.5 ø 9.5 ø 9. 5 Sound pressure level (db(a)) Diversity 135% 135% 130% 135% 44HP 48HP

29 29 Space saving model (Combination) Equivalent HP 50HP 52HP 54HP Model name 50Hz MMY- AP5016T8P-SG AP5216T8P-SG AP5416T8P-SG Outdoor unit type Inverter Power supply (* 2 ) 3phase 4wires 50Hz 400V ( V) Outdoor unit model 50Hz MMY- MAP18B6T8P-SG MAP1606T8P-SG MAP1606T8P-SG MAP18B6T8P-SG MAP18B6T8P-SG MAP1606T8P-SG MAP18B6T8P-SG MAP18B6T8P-SG MAP18B6T8P-SG Capacity 100% (kw) Cooling (* 1 ) Power consumption (kw) Starting current Soft start Soft start Soft start Running current (A) EER Capacity 100% (Energy Efficiency Ratio) Capacity 50% Total weight (kg) Compressor Motor output (kw) 6.9 x x x x x x x x x 2 Fan unit Motor output (kw) Air volume (m 3 /h) 12,600 12,600 12,600 12,600 12,600 12,600 12,600 12,600 12,600 Gas side (mm) ø 41.3 ø 41.3 ø 41.3 Refrigerant Main pipe diameter Liquid side (mm) ø 22.2 ø 22.2 ø 22.2 piping Balance pipe (mm) ø 9.5 ø 9.5 ø 9.5 Sound pressure level Diversity (db(a)) % % % Technical specifications Space saving model (Combination) Equivalent HP 56HP 58HP 60HP Model name 50Hz MMY- AP5616T8P-SG AP5816T8P-SG AP6016T8P-SG Outdoor unit type Inverter Power supply (* 2 ) 3phase 4wires 50Hz 400V ( V) Outdoor unit model 50Hz MMY- MAP2006T8P-SG MAP18B6T8P-SG MAP18B6T8P-SG MAP2206T8P-SG MAP18B6T8P-SG MAP18B6T8P-SG MAP2206T8P-SG MAP2206T8P-SG MAP1606T8P-SG Capacity 100% (kw) Cooling (* 1 ) Power consumption (kw) Starting current Soft start Soft start Soft start Running current (A) EER Capacity 100% (Energy Efficiency Ratio) Capacity 50% Total weight (kg) Compressor Motor output (kw) 7.6 x x x x x x x x x 2 Fan unit Motor output (kw) Air volume (m 3 /h) 17,900 12,600 12,600 18,500 12,600 12,600 18,500 18,500 12,600 Gas side (mm) ø 41.3 ø 41.3 ø 41.3 Refrigerant Main pipe diameter Liquid side (mm) ø 22.2 ø 22.2 ø 22.2 piping Balance pipe (mm) ø 9.5 ø 9.5 ø 9.5 Sound pressure level (db(a)) Diversity 135% 130% 135% *1 The source voltage must not flucture more than ±10%. *2 Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB The standard piping means that main pipe length is 5m, branching pipe length is 2.5m of branch piping connected with a 0 meter height.

30 30 cations Equivalent HP Model name 50Hz (MMY-) 14HP MAP1406T8P-SG 18HP MAP1806T8P-SG Capacity 100% (kw) Cooling (* 2 ) Power consumption Starting current (kw) 11.9 Soft start 14.0 Soft start Running current (A) EER Capacity 100% Capacity 50% External dimensions (Height / Width / Depth) (mm) 1,800 / 1,210/ 780 1,800/1,600/780 Total weight (kg) Compressor Motor output (kw) 4.8 x x 2 Fan unit Motor output (kw) Air volume ( m 3 /h) 12,200 17,300 Gas side (mm) ø 28.6 ø 28.6 Refrigerant Main pipe diameter Liquid side (mm) ø 15.9 ø 15.9 piping Balance pipe (mm) ø 9.5 ø 9.5 Sound pressure level (db(a)) Diversity 145% 150% Recommended isolator (A) Individual isolator is recommended for each outdoor unit

31 31 (Combination) Equivalent HP Model name 50Hz MMY- AP2026T8P-SG AP2226T8P-SG AP2626T8P-SG Outdoor unit type Inverter Power supply (* 1 ) 3phase 4wires 50Hz 400V ( V) Outdoor unit model 50Hz MMY- MAP1006T8P-SG MAP1006T8P-SG MAP1206T8P-SG MAP1006T8P-SG MAP1406T8P-SG MAP1206T8P-SG Capacity 100% (kw) Cooling (* 2 ) Power consumption (kw) Starting current Soft start Soft start Soft start Running current ( A) EER Capacity 100% Capacity 50% Total weight (kg) Compressor Motor output ( kw) 3.1 x x x x x x 2 Fan unit Motor output (kw) Air volume (m 3 /h) 9,700 9,700 12,200 9,700 12,200 12,200 Gas side (mm) ø 28.6 ø 28.6 ø 34.9 Refrigerant Main pipe diameter Liquid side (mm) ø 15.9 ø 19.1 ø 19.1 piping Balance pipe (mm) ø 9.5 ø 9.5 ø 9.5 Sound pressure level (db(a)) Diversity 150% 140% 140% 20HP 22HP 26HP cations Equivalent HP Model name 50Hz MMY- AP2826T8P-SG AP3026T8P-SG AP3426T8P-SG Outdoor unit type Inverter Power supply (* 1 ) 3phase 4wires 50Hz 400V ( V) Outdoor unit model 50Hz MMY- MAP1406T8P-SG MAP1406T8P-SG MAP1606T8P-SG MAP1406T8P-SG MAP1806T8P-SG MAP1606T8P-SG Capacity 100% (kw) Power consumption (kw) Starting current Soft start Soft start Soft start Running current (A) Cooling (* 2 ) EER Capacity 100% Capacity 50% Total weight (kg) Compressor Motor output (kw) 4.8 x x x x x x 2 Fan unit Motor output ( kw) Air volume (m 3 /h) 12,200 12,200 12,600 12,200 17,300 12,600 Gas side (mm) ø 34.9 ø 34.9 Refrigerant Main pipe diameter Liquid side (mm) ø 19.1 ø 19.1 ø 19.1 piping Balance pipe mm) ø 9.5 ø 9.5 ø 9.5 ø 34.9 Sound pressure level (db(a)) Diversity 145% 140% 140% 28HP 30HP (Combination) 34HP *1 *2 Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB

32 32 (Combination) Equivalent HP 36HP Model name 50Hz MMY- AP3626T8P-SG AP3826T8P-SG AP4026T8P-SG Outdoor unit type Inverter Power supply (* 1 ) 3phase 4wires 50Hz 400V ( V) Outdoor unit model 50Hz MMY- MAP1206T8P-SG MAP1206T8P-SG MAP1206T8P-SG MAP1406T8P-SG MAP1206T8P-SG MAP1206T8P-SG MAP1406T8P-SG MAP1406T8P-SG MAP1206T8P-SG Capacity 100% (kw) Cooling (* 2 ) Power consumption (kw) Starting current S oft start Soft start Soft start Running current (A) EER Capacity 100% Capacity 50% Total weight (kg) Compressor Motor output (kw) 3.9 x x x Fan unit Motor output (kw) Air volume (m 3 /h) 12,200 12,200 12,200 12,200 12,200 12,200 12,200 12,200 12,200 Gas side (mm) ø 41.3 ø 41.3 ø Refrigerant Main pipe diameter Liquid side (mm) ø 22.2 ø 22.2 ø piping Balance pipe (mm) ø 9.5 ø 9.5 ø 9. 5 Sound pressure level (db(a)) Diversity 135% 140% 140% 38HP 40HP cations Equivalent HP Model name 50Hz MMY- AP4226T8P-SG AP4426T8P-SG AP4626T8P-SG 42HP Outdoor unit type Inverter Power supply (* 1 ) 3phase 4wires 50Hz 400V ( V) Outdoor unit model 50Hz MMY- MAP1406T8P-SG MAP1406T8P-SG MAP1406T8P-SG MAP1606T8P-SG MAP1406T8P-SG MAP1406T8P-SG MAP1606T8P-SG MAP1606T8P-SG MAP1406T8P-SG Capacity 100% (kw) Cooling (* 2 ) Power consumption (kw) Starting current Soft start Soft start Soft start Running current (A) EER Capacity 100% Capacity 50% Total weight (kg) Compressor Motor output (kw) x x2 5.8 x2 4.8 x 2 Fan unit Motor output (kw) Air volume (m 3 /h) 12,200 12,200 12,200 12,600 12,200 12,200 12,600 12,600 12,200 Gas side (mm) ø 41.3 ø 41.3 ø Refrigerant Main pipe diameter Liquid side (mm) ø 22.2 ø 22.2 ø piping Balance pipe (mm) ø 9.5 ø 9.5 ø 9. 5 Sound pressure level (db(a)) Diversity 145% 140% 140% 44HP (Combination) 46HP

33 33 (Combination) Equivalent HP 50HP Model name 50Hz MMY- AP5026T8P-SG AP5226T8P-SG AP5426T8P-SG Outdoor unit type Inverter Power supply (* 2 ) 3phase 4wires 50Hz 400V ( V) Outdoor unit model 50Hz MMY- MAP1806T8P-SG MAP1606T8P-SG MAP1606T8P-SG MAP2006T8P-SG MAP1606T8P-SG MAP1606T8P-SG MAP2006T8P-SG MAP2006T8P-SG MAP1406T8P-SG Capacity 100% (kw) Cooling (* 1 ) Power consumption (kw) Starting current Soft start Soft start Soft start Running current (A) EER Capacity 100% Capacity 50% Total weight (kg) Compressor Motor output (kw) 6.5 x x x x x x x x x 2 Fan unit Motor output (kw) Air volume (m 3 /h) 17,300 12,600 12,600 17,900 12,600 12,600 17,900 17,900 12,200 Gas side (mm) ø 41.3 ø 41.3 ø Refrigerant Main pipe diameter Liquid side (mm) ø 22.2 ø 22.2 ø piping Balance pipe (mm) ø 9.5 ø 9.5 ø 9. 5 Sound pressure level (db(a)) Diversity 140% 135% 145% 52HP 54HP cations Equivalent HP Model name 50Hz MMY- AP5626T8P-SG AP5826T8P-SG (Combination) Outdoor unit type Inverter Power supply (* 2 ) 3phase 4wires 50Hz 400V ( V) Outdoor unit model 50Hz MMY- MAP2006T8P-SG MAP2006T8P-SG MAP1606T8P-SG MAP2206T8P-SG MAP2006T8P-SG MAP1606T8P-SG Capacity 100% (kw) Cooling (* 1 ) Power consumption (kw) Starting current Soft start Soft start Running current (A) EER Capacity 100% Capacity 50% Total weight (kg) Compressor Motor output (kw) 7.6 x x x x x x 2 Fan unit Motor output (kw) Air volume (m 3 /h) 17,900 17,900 12,600 18,500 17,900 12,600 Gas side (mm) ø 41.3 ø Refrigerant Main pipe diameter Liquid side (mm) ø 22.2 ø piping Balance pipe (mm) ø 9.5 ø 9. 5 Sound pressure level (db(a)) Diversity 140% 135% 56HP 58HP *1 *2 Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB The standard piping means that main pipe length is 5m, branching pipe length is 2.5m of branch piping connected with a 0 meter height.

34 34 Outdoor units external drawings Model : MMY-MAP0806T8P-SG MMY-MAP1006T8P-SG MMY-MAP1206T8P-SG MMY-MAP14B6T8P-SG Model Name A MAP0806 type 19.1 MAP1006 type 22.2 MAP1206 type 28.6 MAP14B6 type 28.6 Square hole (for freight handling) 2-60X200 Balance pipe connec on port Ø9.5 Gas pipe connec on port ØA Liquid pipe connec on port Ø15.9 (Note) 1. IF there is an obstacle at the upper side of the outdoor unit, set the top end of the outdoor unit 2000mm apart from the obstacle 2. Limit the height of the obstacle surrounding the outdoor unit to 800mm or less from the bo om end of the outdoor unit. 3. Draw out the pipe procured locally to the front of the outdoor unit horizontally and keep 500mm or more between the outdoor unit and traversing pipe if placing pipe transversely. 4. Dimensional drawing of corrosion heavey protec on model is the same as that of standard model. (Unit:mm)

35 35 Model : MMY-MAP1406T8P-SG MMY-MAP1606T8P-SG MMY-MAP18B6T8P-SG Square hole (for freight handling) 2-60X200 Balance pipe connec on port Ø9.5 Gas pipe connec on port Ø28.6 (Note) 1. IF there is an obstacle at the upper side of the outdoor unit, set the top end of the outdoor unit 2000mm apart from the obstacle 2. Limit the height of the obstacle surrounding the outdoor unit to 800mm or less from the bo om end of the outdoor unit. 3. Draw out the pipe procured locally to the front of the outdoor unit horizontally and keep 500mm or more between the outdoor unit and traversing pipe if placing pipe transversely. 4. Dimensional drawing of corrosion heavey protec on model is the same as that of standard model. Liquid pipe connec on port Ø15.9 (Unit:mm)

36 36 Model : MMY-MAP1806T8P-SG MMY-MAP2006T8P-SG MMY-MAP2206T8P-SG Model Name A MAP1806 type 15.9 MAP2006 type 15.9 MAP2206 type 19.1 Square hole (for freight handling) 2-60X200 (Note) 1. IF there is an obstacle at the upper side of the outdoor unit, set the top end of the outdoor unit 2000mm apart from the obstacle 2. Limit the height of the obstacle surrounding the outdoor unit to 800mm or less from the bo om end of the outdoor unit. 3. Draw out the pipe procured locally to the front of the outdoor unit horizontally and keep 500mm or more between the outdoor unit and traversing pipe if placing pipe transversely. 4. Dimensional drawing of corrosion heavey protec on model is the same as that of standard model. Balance pipe connec on port Ø9.5 Gas pipe connec on port Ø28.6 Liquid pipe connec on port ØA (Unit:mm)

37 37

38 38

39 39 Cooling capacity (HP equivalent) Console Floor standing cabinet type Floor standing concealed type Floor standing type Large capacity floor standing type 007 type 2.2 kw (0.8HP) MML-AP0074NH-E MML-AP0074H-E MML-AP0074BH-E 009 type 2.8 kw (1HP) MML-AP0094NH-E MML-AP0094H-E MML-AP0094BH-E 012 type 3.6 kw (1.25HP) MML-AP0124NH-E MML-AP0124H-E MML-AP0124BH-E 015 type 4.5 kw (1.7HP) MML-AP0154NH-E MML-AP0154H-E MML-AP0154BH-E MMF-AP0156H-E 018 type 5.6 kw (2HP) MML-AP0184NH-E MML-AP0184H-E MML-AP0184BH-E MMF-AP0186H-E 024 type 7.1 kw (2.5HP) MML-AP0244H-E MML-AP0244BH-E MMF-AP0246H-E 027 type 8.0 kw (3HP) MMF-AP0276H-E 030 type 9.0 kw (3.2HP) 036 type 11.2 kw (4HP) MMF-AP0366H-E 048 type 14.0 kw (5HP) MMF-AP0486H-E 056 type 16.0 kw (6HP) MMF-AP0566H-E 072 type 22.4 kw (8HP) 096 type 28.0 kw (10HP) 144 type 45.0kW (16HP) MMF-AP0723DH-V/H-VA/VB MMF-AP0963DH-V/H-VA/VB MMF-AP1443DH-V/H-VA/VB 192 type 56.0kW (20HP) MMF-AP1923DH-V/H-VA/VB Air-to-air heat exchanger Air volume Fresh air intake Indoor unit type Air volume Air-to-air heat exchange with DX-coil type r* 150 m³/h 150 m³/h VN-M150HE 250 m³/h 250 m³/h VN-M250HE 350 m³/h 350 m³/h VN-M350HE 500 m³/h MMD -VN502HEXE 500 m³/h VN-M500HE 650 m³/h 650 m³/h VN-M650HE 800 m³/h MMD -VN800HEXE 800 m³/h VN-M800HE 1000 m³/h MMD -VN1002HEXE/ m³/h VN-M1000HE 1500 m³/h 1500 m³/h VN-M1500HE 2000 m³/h 2000 m³/h VN-M2000HE 1080 m³/h 1680 m³/h MMD -AP0481HFE MMD-AP0721HFE *: Does not connect to refrigerant piping from outdoor unit. Control wires can be connected m³/h MMD-AP0961HFE

40 40 MMU-AP***4HP-E Individual louver control The angles of each of the four louver can be set individually = (1) Standard swing (2) Diagonally opposite swing (3) Turn-around swing Note: RBC-AMT32E, RBC-AMS51E only Technical specifications RBC-U31PGP(W)-E Model name MMU- AP0094HP-E AP0124HP-E AP0154HP-E AP0184HP-E AP0244HP-E AP0274HP-E AP0304HP-E AP0364HP-E AP0484HP-E AP0564HP-E Cooling (kw) Electrical characteristics Power requirements Power consumption 50 Hz (kw) 1-phase 50Hz 230V ( V) Appearance (Ceiling panel) Model RBC-U31PGP(W)-E External dimensions: Main unit (Ceiling panel)* Height (mm) 256 (30)* 319 (30)* Width (mm) 840 (950)* Depth (mm) 840 (950)* Total weight: Main unit (Ceiling panel)* (kg) 18 (4)* 20 (4)* 25 (4)* Fan unit Standard air flow (High/Mid/Low) (m 3 /h) 800/730/ / 830/ / 920/ /920/ / 1110/ / 1430/ / 1430/1130 Motor output (W) / 1520/1230 Connecting pipe Gas side (mm) ø9.5 ø12.7 ø15.9 Liquid side (mm) ø6.4 ø9.5 Drain port 25 (Polyvinyl chloride tube) (nominal dia.) (mm) Sound pressure level* 2 30/29/27 31/29/27 32/29/27 35/31/28 38/33/30 43/38/32 46/38/33 46/40/33 (High/Mid/Low) (db(a)) * Figures in parentheses are for ceiling panels. Note 1 : The capacities are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 m height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB

41 41 MMU-AP0074HP-E to AP0564HP-E 408 Electric parts box Wireless sensor mounting section (RBC-AX32U can be connected four corners) Air outlet 518 Celling bottom surface Knockout for fresh air intake or less Z view Bottom face of ceiling Stand-up 661 or less *( ): AP0364 to AP0564 Drain standing-up size Stand-up 850 or less (183) Z 35 * Bottom face of ceiling ±20 Hanging bolt pitch 950 Panel external dimension For branch duct knockout square hole Hanging bolt M10 or W3/ 8 procured locally n 780 Hanging bolt pitch Panel external dimension Ceiling panel (Sold separately) Model MMD- A B C AP0094HP-E, AP0124HP-E 256 Ø9.5 Ø6.4 AP0154HP-E, AP0184HP-E AP0244HP-E, AP0274HP-E, AP0304HP-E AP0364HP-E, AP0484HP-E, AP0564HP-E Ø12.7 Ø15.9 Ø15.9 Ø6.4 Ø9.5 Ø9.5 A or more 1000 or more 860 to 910 Ceiling open dimension For branch duct knockout square hole 150 (Also located on the back) Drai pipe connectingport Refrigerant pipe connecting port (Gas side) B Refrigerant pipe connecting port (Liquid side) C Wiring connection port 1000 or more 1000 or more 15 or more 860 to 910 Ceiling open dimension Space required for installation and servicing 200 Check port ( 450) (Unit: mm) Options Air discharge direction kit Auxiliary fresh air flange TCB-FF101URE2 TCB-BC1602UE Fresh air inlet box TCB-GB1602UE TCB-GFC1602UE Ceiling panel RBC-U31PG(W)-E Spacer for height adjustment TCB-SP1602UE Air inlet grille

42 42 Compact 4-way Casse e ( ) Type MMU-AP***4MH-E Perfect for grid system ceiling This compact unit ( mm) ts perfectly into ceilings and matches standard architectural modules, without the need to cut ceiling les. The aps fold ghtly against the ceiling when opera on stops so that the ceiling is a ected only slightly even if air condi oning is installed. Designed for simple & easy installa on and maintenance The slim design is only 268 mm in height even when an electrical box is located inside the unit. Easy installa on is also possible using the panel adjust pocket. Use the adjust pocket func on for ne adjustments a er installa on. Available for ceilings up to 3.5 m in height. The drain-checking hole makes it possible to check the drain pan through the side case. 3.5m RBC-UM11PG(W)E Technical specifications Drain-checking hole Maximum height Model name MMU- AP0074MH-E AP0094MH-E AP0124MH-E AP0154MH-E AP0184MH-E Cooling/Capacity * 1 (kw) Electrical characteristics Power requirement Power consumption 50 Hz/ (kw) Appearance (Ceiling panel) Model RBC-UM11PG(W)-E External dimensions: Main unit (Ceiling panel)* Height (mm) 268 (27)* Width (mm) 575 (700)* Depth (mm) 575(700)* Total weight: Main unit (Ceiling panel)* (kg) 17 (3)* Fan unit Standard air flow (High/Mid/Low) (m 3 /h) 552/462/ /468/ /504/ /552/ /642/522 Motor output (W) 60 Gas side (mm) ø9.5 ø12.7 Connecting pipe Liquid side (mm) ø6.4 Drain port (nominal dia.) 25 (Polyvinyl chloride tube) Sound pressure level* 2 (High/Mid/Low) (db(a)) 36/32/28 37/33/28 37/33/29 40/35/30 44/39/34 * Figures in parentheses are for ceiling panels. Note 1 : The capacities are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 m height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB

43 43 MMU-AP0074MH-E to AP0184MH-E Celling bottom surface Model MMD- A Knockout square hole AP0074MH-E, AP0094MH-E, AP0124MH-E AP0154MH-E, AP0184MH-E Ø 9.5 Ø Celling bottom surface Electric parts box Knockout for air intake Check port ( 450) Refrigerant pipe connecting port (Gas side) A Refrigerant pipe connecting port (Liquid side) Wiring connection port For branch duct knockout square hole 150 Hanging bolt pitch 525 Ceiling open dimension 595 to 660 Panel external dimension Bottom face of ceiling 177 Hanging bolt pitch 525 Ceiling open dimension 595 to 660 Drain standing-up size Ceiling open dimension 595 to 660 Panel external dimension Hanging bolt M10 or W3/8 procured locally Space required for installation and servicing Drain pipe connecting port 1000 or more 1000 or more Bottom face of ceiling Ceiling panel(sold separately) 1000 or more 15 or more Obstacle Ceiling open dimension 595 to 660 Indoor unit 15 or more 300 Stand-up or less Stand-up 850 or less (Unit: mm) Options Auxiliary fresh air flange TCB-FF101URE2 Ceiling panel RBC-UM11PG(W)E

44 44

45 45 MMU-AP0072WH to AP0152WH Electric parts box 815 Hanging bolt 4-M10 procured locally Adjust cover Wireless sensor mounting section 680 Panel external dimension 620 Ceiling open dimension 380 Hanging bolt pitch 880 Hanging bolt pitch 1000~1010 Ceiling open dimension 1050 Panel external dimension 77 Bottom face of ceiling Ceiling panel (sold separetely) Space required for installation and servicing 5 or more or less 609 or less 850 or less Refrigerant pipe connecting port (Liquid side) Refrigerant pipe connecting port (Gas side) Drain pipe connecting port or more ceiling Drain standing-up size Knockout hole for auxiliary fresh air intake flange (Only at reverse side) Power supply connecting port (Unit: mm) MMU-AP0182WH to AP0302WH Electric parts box 1180 Hanging bolt 4-M10 procured locally Adjust cover Wireless sensor mounting section 680 Panel external dimension 620 Ceiling open dimension 380 Hanging bolt pitch 1245 Hanging bolt pitch 1365~1357 Ceiling open dimension 1415 Panel external dimension 77 Bottom face of ceiling Ceiling panel (sold separetely) Space required for installation and servicing 5 or more 1000or more or less 559 or less 850 or less ceiling Drain standing-up size Refrigerant pipe connecting port (Liquid side) Refrigerant pipe connecting port (Gas side) Knockout hole for auxiliary fresh air intake flange (Only at reverse side) Drain pipe connecting port Power supply connecting port (Unit: mm) MMU-AP0362WH to AP0562WH 680 Panel external dimension 620 Ceiling open dimension 380 Hanging bolt pitch 1665 Hanging bolt pitch 1785~1795 Ceiling open dimension 1835 Panel external dimension Electric parts box 77 Bottom face of ceiling Ceiling panel (sold separetely) Space required for installation and servicing 5 or more 1000or more 300 or less Hanging bolt 4-M10 procured locally or less or less ceiling Drain standing-up size Adjust cover Refrigerant pipe connecting port (Liquid side) Refrigerant pipe connecting port (Gas side) Knockout hole for auxiliary fresh air intake flange (Only at reverse side) Wireless sensor mounting section Drain pipe connecting port Power supply connecting port (Unit: mm) Options Ceiling panel RBC-UW283PG(W)-E RBC-UW803PG(W)-E RBC-UW1403PG(W)-E Filter chamber TCB-FC283UW-E TCB-FC803UW-E TCB-FC1403UW-E Super long life filter TCB-LF283UW-E TCB-LF803UW-E TCB-LF1403UW-E Auxiliary fresh air flange TCB-FF151US-E

46 46 1-way Air Discharge Casse e Type MMU-AP***4YH-E MMU-AP***4SH-E The perfect choice for hotels and recep on areas Silent sound design ensures the quiet required for the o ce. Fresh air intake is possible (MMU-AP***4SH-E) Prepara ons/connec on possible with a circle duct ange. Ideal for smaller rooms where one-way air distribu on is required. Able to blow air straight out. Condensate drain pump included. Long-life lters ed as standard. Technical specifications Model name MMU- AP0074YH-E AP0094YH-E AP0124YH-E AP0154SH-E AP0184SH-E AP0244SH-E Cooling/Capacity * 1 (kw) Electrical characteristics Power requirement -p Power consumption 50 Hz/60 Hz (kw) Appearance (Ceiling panel) Model RBC-UY136PG RBC-US21PGE External dimensions: Main unit (Ceiling panel)* Height (mm) 235 (18)* 200 (20)* Width (mm) 850 (1050)* 1000 (1230)* Depth (mm) 400 (470)* 710 (800)* Total weight: Main unit (Ceiling panel)* (kg) 22 (3.5)* 21 (5.5)* 22 (5.5)* Fan unit Standard air flow (High/Mid/Low) (m 3 /h) 540/480/ /690/ /720/ /960/810 Motor output (W) Gas side (mm) ø9.5 ø12.7 ø15.9 Connecting pipe Liquid side (mm) ø6.4 ø9.5 Drain port (nominal dia.) 25 (Polyvinyl chloride tube) Sound pressure level* 2 (High/Mid/Low) (db(a)) 42/39/34 37/35/32 38/36/34 45/41/37 * Figures in parentheses are for ceiling panels. Note 1 : The capacities are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 m height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB

47 47 MMU-AP0074YH-E to AP0124YH-E 20 Panel external dimension 1050 Ceiling open dimension Hanging bolt pitch Space required for installation and servicing Power supply connecting port 200 Drain pipe connecting port Refrigerant pipe connecting port (Gas side) Refrigerant pipe connecting port (Liquid side) Panel mounting hole 5 positions 110 Discharge louver Air inlet Ceiling panel (Sold separately) Hanging bolt pitch Center of panel Hanging bolt 4-M procured locally Air outlet Ceiling open dimension Panel external dimension 470 Bottom face of ceiling 400 Support metal 100 or less Stand-up 150 or less Stand-up 350 or less Bottom face of ceiling Drain standing-up size 100 or more 245 or more 200 or more 100 or more (Unit: mm) MMU-AP0154SH-E to AP0244SH-E Fresh air intake ( 92 knockout hole) Panel external dimension 1230 Ceiling open dimension Hanging bolt pitch 1060 Bottom face of ceiling Hanging 135 bolt pitch Ceiling open dimension 760 Panel externaldimension Refrigerant pipe connecting port (Gas side) Refrigerant pipe connecting port (Liquid side) Wiring connection port Hanging bolt M10 or W3/8 local arrange Drain pipe connecting port Knockout hole for front blow out Ceiling panel (Sold separately) Wireless sensor mounting section 140 or less Bottom face of ceiling Stand-up 696 or less Stand-up 850 or less 205 or more Drain standing-up size Space required for installation and servicing 1000 or more Ceiling 1000 or more Obstacle 200 or more (Unit: mm) Options AP0074YH-E/AP0094YH-E/AP0124YH-E Front air discharge unit TCB-BUS21HWE Ceiling panel RBC-UY136PG Auxiliary fresh air flange TCB-FF101URE2 AP0154SH-E/AP0184SH-E/AP0244SH-E Ceiling panel RBC-US21PGE

48 48 Slim Duct Type MMD-AP***4SPH-E Func onal design Only 210 mm in height for greater applica on exibility. 4-step sta c pressure setup. Concealed installa on within a ceiling void. Slim & quiet Perfect comfort throughout the room. Can be used with any style of air di user. Quiet, powerful opera on. Auxiliary fresh air intake available. Technical specifications Model name MMD- AP0074SPH-E AP0094SPH-E AP0124SPH-E AP0154SPH-E AP0184SPH-E AP0244SPH-E AP0274SPH-E Cooling/Capacity* 1 (kw) Electrical characteristics Power supply Power consumption 50 Hz/60 Hz (kw) 1-phase 50Hz 230V ( V) (Separate power supply for indoor units required.) External dimensions Height (mm) 210 Width (mm) Depth (mm) 645 Total weight (kg) Standard air flow (High/Mid/Low) (m 3 /h) 540/470/ /520/ /600/ /680/ /1000/900 Fan unit Motor output (W) External static pressure (Pa) (4 steps) (4 steps) (4 steps) (4 steps) Gas side (mm) ø9.5 ø12.7 ø15.9 Connecting pipe Liquid side (mm) ø6.4 ø9.5 Drain port (nominal dia.) 25 (Polyvinyl chloride tube) Sound pressure level* 2 (High/Med./Low) Under air inlet (db(a)) 36/33/30 38/35/32 39/36/33 40/38/36 49/47/44 Back air inlet (db(a)) 28/26/24 29/27/25 32/30/28 33/31/29 38/36/33 Note 1 : The capacities are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 m height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB

49 49

50 Pa. (up to 16.0 kw) and 250 Pa (for 22.4 & 28.0kW) cations Model name MMD- AP0186HP-E AP0246HP-E AP0276HP-E AP0366HP-E AP0486HP-E AP0566HP-E AP0726HP-E AP0966HP-E Electrical characteristics Power requirements Power consumption 50 Hz/60 Hz (kw) 1-phase 50Hz 230V ( V) / 1-phase 60Hz 220V (Separate power supply for indoor units required.) External dimensions Height (mm) Width (mm) 1,000 1,400 1,40 0 Depth (mm) Total weight (kg) Fan unit (Med./Low) Motor output External static pressure (factory setting) (m 3 /h) (W) (Pa) External static pressure (Pa) 800 1,200 1,920 2,100 2,400 3,800 4,800 (660/550) (970/800) (1,560/1,340) (1,740/1,420) (2,040/1,660) (3,200/2,500) (4,200/3,500) Gas side (mm) ø12.7 ø15.9 ø22.2 Connecting pipe Liquid side (mm) ø6.4 ø9.5 ø12.7 Drain port (nominal dia.) 25 (Polyvinyl chloride tube) 25 (Polyvinyl chloride tube) Sound pressure level* 2 (High/Mid/Low) (db(a)) 37 (32/30) 38 (34/31) 41 (37/34) 42 (40/35) 45 (42/37) 44 (40/36) 46 (42/38) Note 1 : The cooling capacities and electrical characteristics The reference piping consists of 5m of main piping and 2.5 of branch piping connected with 0 meter height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B Normally, the values measured in the actual operating envi Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB n the reference piping. ects of external sound.

51 Unit external dimension 1000 (Outside) Unit external dimension 940(Outside) Hole for hanging bolt ( ) Refrigerant pipe connecting port 6.4 (Liquid side) Refrigerant pipe connecting port 12.7 (Gas side) Hanging bolt mounting pitch knockout hole For Auxiliary fresh air flange (Sold separately) Hanging bolt mounting pitch Unit external dimension Wires drawing port Drain pipe connecting port 345 There are the head of the screw(n=4). Make a hole at the installation of inlet duct MMD-AP0186HP-E to AP0276HP-E MMD-AP0726HP-E, AP0966HP-E Space required for installation and servicing Unit external dimension /100 or more downward Flexible drain hose Flexible drain hose (Accessory) (Accessory) 300 or less 1/100 or more downward 618 or less 850 or less 100 or more Air outlet Ceiling or more 2500 or more 70 or 5 or more 275 more Service door (Ceiling opening) Floor surface 324 (Outside) 448 At the time of natural drainage Drain-up piping Air outlet 100 or more Check port 450 Hole for hanging bolt (4-Φ12 30) (Outside) 95 Ceiling Ceiling Aervice space (500 for maintenance of air filter(sold separately)) Air inlet Service door (Ceiling opening) Air inlet 300 or more Service door (Ceiling opening) Hanging bolt mounting pitch 1465 Hanging bolt mounting pitch <Air inlet> Electrical control box (Unit: mm) MMD-AP0366HP-E to AP0566HP-E Unit external dimension (Outside) (Outside) Unit external dimension 1/100 or more downward Flexible drain hose Flexible drain hose (Accessory) (Accessory) 300 or less 1/100 or more downward At the time of natural drainage Drain-up piping 618 or less 850 or less Space required for installation and servicing Air outlet Ceiling or 700 more or more 2500 or more 70 or 5 or more 275 more Service door (Ceiling opening) Floor surface 100 or more Air outlet Drain pipe connecting port (Gravitiational drainage) Drain pipe connecting port Drain pump kit (sold separately) Electrical control box Refrigerant pipe connecting port (Liquid side) O 12.7 (Flare nut connection) Refrigerant pipe connecting port (Gas side) O 22.2 (Brazing connection) Hole for hanging bolt ( ) Refrigerant pipe connecting port 9.5 (Liquid side) Refrigerant pipe connecting port 15.9 (Gas side) 120 Check port Aervice space (700 for maintenance of air filter(sold separately)) Hanging bolt mounting pitch 1465 Wires drawing port 125 knockout hole For Auxiliary fresh air flange (Sold separately) There are the head of the screw(n=4). Make a hole at the installation of inlet duct Hanging bolt mounting pitch Unit external dimension Drain pipe connecting port 345 Ceiling Ceiling Air inlet Service door (Ceiling opening) Air inlet 300 or more Service door (Ceiling opening) 310 Space required for installation and servicing Ceiling 200 or more or more Service door (Ceiling opening) 2500 or more Air outlet Air outlet Floor surface 200 or more Check port or more or more or more (Suction duct) Air inlet Ceiling Service door (Ceiling opening) < When attached the long life filter kit (sold separately)> Air inlet 300 or more Ceiling Service door (Ceiling opening) (Unit: mm) Electrical control box 15 Electrical control box or more Service space If there are enough space under the unit (more than 1000mm) the service door(ceiling opening) is not necessary (Unit: mm) Options Long Life Filter Kit TCB-LK2801DP-E Drain Pump Kit TCB-DP40DP-E

52 52 Concealed Duct Type MMD-AP***6BHP-E High sta c pressure External sta c pressure can be raised as high as 120 Pa, so that all areas of the room can be reached for even temperature distribu on, no ma er how complex the layout. High-li drain pump Built-in high-li drain pump up to 850 mm. Technical specifications Model name MMD- AP0076BHP-E AP0096BHP-E AP0126BHP-E AP0156BHP-E AP0186BHP-E AP0246BHP-E AP0276BHP-E AP0306BHP-E AP0366BHP-E AP0486BHP-E AP0566BHP-E Cooling/Capacity* 1 (kw) Electrical characteristics Power requirements Power consumption 50 Hz (kw) 1-phase 50Hz 230V ( V) / 1-phase 60Hz 220V (Separate power supply for indoor units required.) External dimension Height (mm) 275 Width (mm) ,000 1,400 Depth (mm) 750 Total weight (kg) Standard air flow (Mid/Low) (m 3 /h) 540/ 450/ / 480/ / 660/540 1,200/990/870 1,260/ 1,110/930 1,920/ 1,620/1,380 2,100/ 1,740/1,500 Fan unit Motor output (W) External static pressure (factory setting) (Pa) External static pressure (Pa) (7 steps) Connecting pipe Sound pressure level* 2 (High/Mid/Low) Gas side (mm) ø9.5 ø12.7 ø15.9 Liquid side (mm) ø6.4 ø9.5 Drain port (nominal 25 (Polypropylene tube) dia.) (db(a)) 29/26/23 30/26/23 33/29/25 36/31/27 40/36/33 Note 1 : The capacities are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 m height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB

53 53 MMD-AP0076BHP-E to AP0566BHP-E Hanging bolt pitch A Unit external dimension B C (Outside) Flexible drain hose (Accessory) Space required for installation and servicing 5 or more 180(Outside) 64 Unit external dimension 275 1/100 or more downward At the time of natural drainage Refrigerant pipe connecting port 6.4 (Liquid side) Ceiling 100 or more Air outlet or more Service door (Ceiling opening) 2500 or more Floor surface or more Refrigerant pipe connecting port 9.5 (Gas side) Hanging bolt pitch 650 Unit external dimension Drain pipe connecting port knockout hole (For air taking-in air) Electrical control box Air filter Wires drawing-out port 18 Under air intake type Model MMD- A B C D D 229 (Unit:mm) AP0076BHP-E, AP0076BH-E, AP0096BHP-E, AP0096BH-E, AP0126BH-E AP0126BHP-E 765 AP0156BHP-E, AP0156BH-E, AP0186BHP-E AP0186BH-E 765 AP0246BHP-E, AP0246BH-E, AP0276BHP-E, AP0276BH-E, AP0306BHP-E AP0306BH-E 1065 AP0366BHP-E, AP0366BH-E, AP0486BHP-E, AP0486BH-E, AP0566BH-E AP0566BHP-E * Standard filter is provided, but deeper filtration filter needs to be purchased locally. Options TCB-SF56C6BPE TCB-SF80C6BPE TCB-SF160C6BPE

54 54 Ceiling Type MMC-AP***7HP-E Smooth curve for pliant Shape All-new chassis and new rounded design, This new models have been developed in response to customers needs for ceiling units that be er match their room interiors. Smooth curve for pliant Shape New fan has adopted the turbulence preven on rib to op mize the ven la ng way. Air volume has increased and noise level also has decreased compared with previous model. Winds of new ceiling type of 4HP to 6HP can be reached up to 4.3 metre. Temperature measuring section Center 0.5m above the floor 8m 8m 8m 8m 3m 3m Previous model New model New Designed Wide Flap The new air oulet has realized both High noise reduc on and large air volume. Previous model New model 30% Extension Flap control The air ow angle is automa cally set to the most suitable se ng according to your cooling or hea ng needs, and an automa c swing mode enables air ow to reach all areas of the room to create a comfortable ambience. Temperature (deg.c) (C) Technical specifications Model name MMC- AP0157HP-E AP0187HP-E AP0247HP-E AP0277HP-E AP0367HP-E AP0487HP-E AP0567HP-E Cooling/Capacity* 1 (kw) Electrical characteristics Power requirements Power consumption 50 Hz (kw) 1-phase 50Hz 230V ( V) / 1-phase 60Hz 220V (Separate power supply for indoor units required.) External dimensions Height (mm) 235 Width (mm) 950 1,269 1,586 Depth (mm) 690 Total weight (kg) Fan unit Standard air flow (High/Mid/Low) (m 3 /h) 840 /690/ /720/ /1020/ /1350/ /1530/ /1650/1260 Motor (W) Gas side (mm) ø12.7 ø15.9 Connecting pipe Liquid side (mm) ø6.4 ø9.5 Drain port (nominal dia.) 20 (Polyvinyl chloride tube) Sound pressure level* 2 (High/Mid/Low) (db(a)) 36/34/28 37/35/28 41/36/29 44/38/32 44/41/35 46/42/36 Note 1 : The capacities are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 m height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB

55 55 MMC-AP0157HP-E to AP0567HP-E Z A B Z view Space required for installation and servicing Hanging bolt Model MMC- AP0157HP-E, AP0187HP-E AP0247HP-E, AP0277HP-E AP0367HP-E, AP0487HP-E, AP0567HP-E A B Within 50 Ceiling surface Unit 250 or more 250 or more (Front side to be positioned ) horizontally (Unit: mm) Options TCB-KP13CE, TCB-KP23CE Elbow piping TCB-DP31CE Drain pump kit TCB-PCUC1E Optional connecting kit

56 56 High-wall Type (3 series) MMK-AP***3H Elegant and slim This classic high-wall is elegant and slim; it can easily blend in with any room interior. Total comfort is granted, thanks also to the 70 direc onal auto-swing louver that provides uniform air distribu on. Remote controller MMK-AP0073H to AP0243H c 50 c 7 Space required for installation and servicing T or mor or mor 170 or mor (Unit: mm) Technical specifications Model name MMK- AP0073H AP0093H AP0123H AP0153H AP0183H AP0243H Cooling capacity* 1 (kw) Power requirements 1 phase 50Hz 230V ( V) (Separate power supply for indoor units required.) Electrical characteristics Power consumption Hz (kw) Height (mm) 320 External dimensions Width (mm) 1050 Depth (mm) 228 Total weight (kg) 15 Standard air flow Fan unit (High/Mid/Low) (m 3 /h) 570/450/ /480/ /660/ /750/570 Motor output (W) 30 Gas side (mm) ø9.5 ø12.7 ø15.9 Connecting pipe Liquid side (mm) ø6.4 ø9.5 Drain port (nominal dia.) 16 (polyvinyl chloride tube) Sound pressure level* 2 (High/Mid/Low) (db(a)) 35/31/28 37/32/28 41/36/33 46/39/34 Note 1 : The capacities are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 m height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB

57 Console Type MML-AP***4NH-E 57 Features Elegant & simple design makes this unit a perfect t for shops, o ce buildings, and luxury apartments. Bo om ow func onality ensures comfortable air bi- ow for an advantage in hea ng and oor warming. Mul -func on opera on is convenient, making adjustments by the user possible using the wireless remote controller. Remote controller MML-AP0074NH-E to AP0184NH-E Dia. 80mm Space required for installation and servicing A C C Back body Front panel Vertical louver (Upper air outlet) Air inlet grille Air filter Heat exchanger 220 Air inlet Air inlet Air inlet 600 Connecting pipe Gas side Connecting pipe Liquid side 45 Bottom air outlet Dia. 80mm Knock out system Mounting screw Mounting screw Dia. 80mm Knock out system Dia. 80mm (Unit: mm) Technical specifications Model name MML- AP0074NH-E AP0094NH-E AP0124NH-E AP0154NH-E AP0184NH-E Cooling/Capacity* 1 (kw) Electrical Power requirements 1-phase 50Hz 230V ( V ) Separate power supply for indoor units required.) characteristics Power consumption 50 Hz (kw) Height (mm) 600 External dimensions Width (mm) 700 Depth (mm) 220 Total weight (kg) 17 Fan unit Standard air flow (High/Mid/Low) (m 3 /h) 510/366/ /408/ /468/ /528/426 Motor output (W) 41 Gas side (mm) ø9.5 ø12.7 Connecting pipe Liquid side (mm) ø6.4 Drain port (nominal dia.) 16 (Polyvinyl chloride tube) Sound pressure level* 2 (High/Mid/Low) (db(a)) 38/32/26 40/34/29 43/37/31 47/40/34 Note 1 : The capacities are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 m height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB

58 58 Floor Standing Cabinet Type MML-AP***4H-E Slim & compact design Under-window moun ng does not block ligh ng. Slim & compact design Distribu on can be reversed to suit occupant preference. Air blown from front panel (factory default) Air blown from top Indoor unit size of 2.2 kw to 7.1 kw is the same. MML-AP0074H-E to AP0244H-E mounting (2-10) Lower refrigerant piping port (knockout hole 50x100) 130 Drain pipe connecting port Refrigerant pipe connecting port (Liquid side) Refrigerant pipe connecting port (Gas side) (Gas) 162 (Liquid) 130 (Drain) (Liquid) (Gas) Air outlet 230 Hole for wall mounting (knockout hole) Piping positional drawing 630 Air inlet 950 Refrigerant pipe port (both sides) (knockout hole 50x100) Power supply cord hole ( 26 knockout hole) Earth screw (M6) (100 left side) Long hole for wall mounting Refrigerant pipe port (Knockout hole 130) 1000 or more Space required for installation and servicing Wall (Front side) 500 or more 300 or more (Front side) Wall (Unit: mm) Technical specifications Model name MML- AP0074H-E AP0094H-E AP0124H-E AP0154H-E AP0184H-E AP0244H-E Cooling/ Capacity* 1 (kw) Electrical Power requirement -phase 50Hz 230V ( V ) ( Separate ower supply for indoor units required.) characteristics Power consumption 50 Hz/60 Hz (kw) Height (mm) 630 External dimensions Width (mm) 950 Depth (mm) 230 Total weight (kg) Fan unit Standard air flow (High/Mid/Low) (m 3 /h) 480/420/ /780/ /930/780 Motor output (W) Gas side (mm) ø9.5 ø12.7 ø15.9 Connecting pipe Liquid side (mm) ø6.4 ø9.5 Drain port (nominal dia.) 20 (Polyvinyl chloride tube) Sound pressure level* 2 (High/Mid/Low) (db(a)) 39/37/35 45/41/38 49/44/39 Note 1 : The capacities are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 m height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB

59 Floor Standing Concealed Type 59 MML-AP***4BH-E Cool air makes for a pleasant indoor environment Install it under a window and air-condi on any room e ec vely. Easy maintenance Simpli ed design of fan and drainage pipe eases maintenance. MML-AP0074BH-E to AP0244BH-E 5 Hole for floor mounting B 50 (Air discharge port size in flange) Ceiling board section Spac e re quir ed for inst allation and se rv icing Electric parts box (earth terminal is provided in inner side) Model MML- AP0074BH-E to AP0124BH-E AP0154BH-E to AP0244BH-E 600 A B C D 4 7 C (Air discharge port size in flange) E 5 8 A D 100 B E 4.7 hole (front side and rear side) 4 15 hole (for mounting rear side) Air filter Expansion valve box hole (left/right side each) Refrigerant pipe connecting port (Liquid side) Refrigerant pipe connecting port (Gas side) or more 150 or more Drain pipe connecting port long hole (Hole for floor mounting) (Unit: mm) Technical specifications Model name MML- AP0074BH-E AP0094BH-E AP0124BH-E AP0154BH-E AP0184BH-E AP0244BH-E Cooling Capacity* 1 (kw) Electrical Power requirements 1-phase 50Hz 230V ( V) / 1-phase 60Hz 220V (Separate power supply for indoor units required.) characteristics Power consumption 50 Hz (kw) Height (mm) 600 External dimensions Width (mm) Depth (mm) 220 Total weight (kg) Fan unit Standard air flow (High/Mid/Low) (m 3 /h) 460/400/ /600/ /790/640 Motor output (W) Gas side (mm) ø9.5 ø12.7 ø15.9 Connecting pipe Liquid side (mm) ø6.4 ø9.5 Drain port (nominal dia.) 20 (Polyvinyl chloride tube) Sound pressure level* 2 (High/Mid/Low) (db(a)) 36/34/32 42/37/33 Note 1 : The capacities are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 m height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB

60 60 Floor Standing Type MMF-AP***6H-E Thin pro le suits interior design Slender, space-saving type ( HP) Wide outlet Corner loca on is also possible, with right and le auto swing. Set the ver cal angle manually. auto swing MMF-AP0156H-E to AP0566H- E Bracket for floor mounting (both sides) pitch pitch 30 3 Air inlet 180 Floor fixing bracket screw positions 640 Bracket for wall mounting Air outlet Rear side pipe hole (φ130 knockout hole) Drain pipe connecting port E 50 F B A C Wall Pipe holes on side (both sides) (knockout hole) Drain pipe port (both sides) (knockout hole) D Earth screw (M4) 164 Space required for installation and servicing 1000 or more 204 Wall (Front side) Model MMF- AP0154H-E to AP0274H-E AP0364H-E to AP0564H-E MMF-AP0151H Liquid side or more A B C Gas side Refrigerant pipe connecting port (Liquid side) 200 or more (Front side) D Refrigerant pipe connecting port (Gas side) Refrigerant piping position Wall MMF-AP0361H Liquid side 165 E F Gas side (Unit: mm) Technical specifi cations Model name MMF- AP0156H-E AP0186H-E AP0246H-E AP0276H-E AP0366H-E AP0486H-E AP0566H-E Cooling/ (kw) Electrical Power requirements 1-phase 50Hz 230V ( V) / (Separate power supply for indoor units required.) characteristics Power consumption 50 Hz (kw) Height (mm) 1750 External dimensions Width (mm) 600 Depth (mm) Total weight (kg) Fan unit Standard air flow (High/Mid/Low) (m 3 /h) 900/780/ /990/ /1620/ /1730/1560 Motor output (W Gas side (mm) ø12.7 ø12.7 Connecting pipe Liquid side (mm) ø6.4 ø9.5 Drain port (nominal dia.) 20 (one side of male screw ) Sound pressure level* 2 (High/Mid/Low) (db(a)) 46/42/37 49/45/39 51/46/41 54/49/44 Note 1 : The capacities are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 m height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB

61 61 MMF-AP0**4DH-V MMF-AP1**4DH-V Floor Standing <Duct Type> (50 Hz/60 Hz) MMF-AP0724DH-V/MMF-AP0964DH-V MMF-AP1444DH-V/MMF-AP1924DH-V MMF-AP0724DH-V, MMF-AP0964DH-V MMF-AP1444DH-V, MMF-AP1924DH-V (Unit: mm) Technical specifi cations Model name MMF- AP0724DH-V AP0964DH-V AP1444DH-V AP1924DH-V Cooling/Heating capacity* 1 (kw) 22.4/ / / /63.0 Electrical Power requirements 3 phase 50/60Hz 400V(Separate power supply for indoor units is required.) characteristics Power consumption 50 Hz/60 Hz (kw) 0.59/ / / /2.26 Height (mm) External dimensions Width (mm) Depth (mm) Total weight (kg) Standard air flow (m 3 /h) Fan unit*2 Motor output (kw) External static pressure (50Hz/60Hz) (Pa) 43/122 39/148 28/111 86/222 Gas side (mm) ø22.2 ø28.6 Connecting pipe Liquid side (mm) ø12.7 ø15.9 Drain port (nominal dia.) 25 (Both sides of male screw) Sound pressure level*3 (db(a)) 54/56 55/57 61/63 62/64 Note 1 : The capacities and electrical characteristics are measured under the conditions specified by JIS B Note 2 : As air volume is fixed, by remote controller, air volume cannot be charged. When required high static pressure and air volume change, a pulley change is requested. Note 3 : The sound level are measured in an anechoic chamber in accordance with JIS B Normally, the sound level measured in the actual operating environment become bigger than the rated figures due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB

62 62 Large c standing type MMF-AP0**4H-VA/VB MMF-AP1**4H-VA/VB Floor Standing <Direct Type> (50 Hz) (60 Hz) MMF-AP0724H-VA/MMF-AP0964H-VA MMF-AP0724H-VB/MMF-AP0964H-VB MMF-AP1444H-VA/MMF-AP1924H-VA MMF-AP1444H-VB/MMF-AP1924H-VB (Unit: mm) T cations Model name (50Hz/60Hz) MMF- AP0724H-VA/VB AP0964H-VA/VB AP1444H-VA/VB AP1924H-VA/VB Cooling/Heating capacity* 1 (kw) 22.4/ / / /63.0 Electrical Power requirements 3 phase 50/60Hz 400V(Separate power supply for indoor units is required.) characteristics Power consumption 50 Hz/60 Hz (kw) 0.56/ / / /2.05 Height (mm) 2,130 2,280 External dimensions Width (mm) 890 1,300 Depth (mm) Total weight (kg) Standard air ow (m 3 /h) 3,600 4,200 7,200 8,400 Fan unit* Motor output (kw) Gas side (mm) ø22.2 ø28.6 Connecting pipe Liquid side (mm) ø12.7 ø15.9 Drain port (nominal dia.) 25 (Both sides of male screw) Sound pressure level* (db(a)) Note 1 : The capacities When required high static pressure and air volume change, a pulley change is requested. Note 3 : The sound level are measured in an anechoic chamber in accordance with JIS B Normally, Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB sound.

63 Fresh Air Intake Indoor Unit Type 63 MMD-AP***HFE Air controller for fresh-air intake Outside sta c pressure maximum 230 Pa (in case of 50 Hz of 5HP). Use of high-performance lter provides more comfortable room environment. Introduces outdoor air at a temperature close to that of the indoor air. Primary processing of fresh outdoor air. Fresh-air intake o en in uences the system, rendering normal control of the air condi oner di cult, or placing large loads on the system and its cooling performance. Therefore it is frequently adopted to handle the fresh air to a certain condi on before the fresh air will enter in the main air condi oner. Fresh air intake indoor unit SMMS-i outdoor unit Indoor unit This device is known as a fresh air intake indoor unit. Fresh air NOTE: The fresh air intake indoor unit is an air condi oner provided to handle the fresh air load and is not to control the room temperature. For correspondence to the load of the indoor air controller, set an air condi oner separately. Technical specifi cations Model name MMD- AP0481HFE AP0721HFE AP0961HFE Cooling/ capacity (Note 1) (kw) Electrical Power supply (kw) 1-phase 50 Hz 230 V ( V) characteristics Power consumption (kw) Height (mm) 492 External dimensions Main unit Width (mm) Depth (mm) 1262 Total weight (kg) Standard air flow (m 3 /h) Fan unit Motor output (kw) External static pressure 50 Hz/60 Hz (Pa) / / / Air flow limit Lower limit/upper limit (m 3 /h) 756/ / /2310 Gas side (mm) ø15.9 ø22.2 Connecting pipe Liquid side (mm) ø9.5 ø12.7 Drain port (mm) 25 Sound pressure level (Note 2) (High/Med./Low) (db(a)) 45/43/41 46/45/44 Operation range Cooling (Note 3) ( C) 5 43 Heating (Note 4) ( C) 5 43 * The setting temperature is C (standard FCU C). * An optional humidifier is not available with fresh air intake indoor unit. * Height difference between fresh air intake indoor units must be within 0.5 m. Height difference between fresh air intake indoor unit and standard FCU must be within 30 m. NOTE 1 Rated conditions Cooling: Outdoor air temperature 33 C DB/28 C WB setting temperature 18 C Heating: Outdoor air temperature 0 C DB/ 2.9 C WB setting temperature 25 C Piping: Length 7.5 m / Height 0 m NOTE 2 Normally, the values measured in the actual operating environment become large than the indicated values due to the effects of external sound. NOTE 3 * When supply air temperature is setting temperature + 3 C or less, fresh air intake indoor unit operates as FAN mode. * When supply air temperature is 19 C or less, Fresh Air Intake Indoor unit operates as FAN mode. NOTE 4 * When supply air temperature is setting temperature 3 C or over, fresh air intake indoor unit operates as FAN mode.

64 64 Use Condi ons In COOL mode, if temperature of the fresh air is below the setup temp. of +3 C, FAN status is automa cally made. When temperature of the fresh air is below 19 C, FAN status is also made regardless of the setup temperature. Fresh air temp. ( C) 10 COOL mode Setup temp. 3 FAN COOL Automatic COOL +3 C operation starts Operable mode and discharge temperature setup range Operation mode At shipment from factory Setup range COOL 18 C 16 to 27 C Long hole for M10 hanging bolt Type Hole dia.-width x Length φ12 x , φ12 x 92 A Hanging bolt pitch B 1328 Hanging bolt pitch Space required for installation and servicing Over Service space MMD-AP0481HFE to AP0961HFE Fresh air intake indoor unit Over 200 Service space Check port Refrigerative piping work example at local site 600 Check port C Blow-off port Discharge temp sensor Discharge port connecting ange ( K ) (Accessory for main unit of product) D E F Refrigerant pipe connecting port (Gas pipe M ) Electric parts box (With cover) Refrigerant pipe connecting port (Liquid pipe N ) Drain pipe connecting port G H I J Suction port Suction port connecting ange ( L ) (Accessory for main unit of product) (Unit: mm) Model MMD- A B C D E F G H I J K L M N AP0961HFE AP0721HFE AP0481HFE M6 10-M6 φ22.2 brazing φ12.7 are 10-M6 10-M6 φ22.2 brazing φ12.7 are 8-M6 6-M6 φ15.9 are φ9.5 are Options Filter chamber TCB-FCY51DFE TCB-FCY100DE Long life prefilter TCB-PF3DE TCB-PF4D-1E Drain pump kit TCB-DP32DFE High-efficiency filter 65 TCB-UFM3DE, TCB-UFM4D-1E High-efficiency filter 90 TCB-UFH7DE, TCB-UFH8D-1E

65 Air -to- Air Heat Exchanger with DX-coil MMD-VN***HEXE/HEXE2 65 Greater comfort and reduced load Flexible control Func onality built into the cooling system reduces load Supply and exhaust fan speed ra os can be changed on cooling beyond that of the heat exchanger itself. for improved air volume control that best matches This improves air quality and ensures maximum comfort the needs of the environment and loca on. throughout room being cooled. Free cooling at night When the air outdoors is cooler at night, the system expels warm air from the room. This reduces the air condi oning load the next day for improved energy e ciency. Remote controller NRC-01HE Technical specifications Model name MMD- VN502HEXE VN802HEXE VN1002HEXE Fresh air conditioning load Cooling (*1) (kw) 4.10 (1.30) 6.56 ( (2.32 Power supply Temperature exchange efficiency 50Hz / 60Hz Enthalpy exchange efficiency 50Hz / 60Hz Fan unit 50Hz / 60Hz Sound pressure 50Hz / 60Hz 1-phase 50Hz 230V ( V) / 1-phase 60Hz 220V (Separate power supply for indoor units required.) (*1) Cooling and heating capacities are based on the following conditions: Cooling capacities are based on : indoor temperature :27 CDB/19 CWB, Outdoor temperature : 35 CDB Heating capacities are based on : indoor temperature :20 CDB, Outdoor temperature : 7 CDB/6 CWB Fan is based on High and Middle ( ): The figures in ( ) indicate the heat reclaimed from the heat recovery ventilator. 1-phase 50Hz 230V (220V-240V) (Separate power supply for indoor units is required.) High (% 5.5 Mid (% 5.5 Low (%) 67.5 High (% 2.0 Cooling Mid (% 2.0 Low (% 4. High (% 6.0 Heating Mid (% 6.0 Low (% 8. High (m 3 /h 50 Standard air flow Mid (m 3 /h 50 Low (m 3 /h 20 High (Pa) 13 External static pressure Mid (Pa) 12 Low (Pa) 10 High (db) 43.0 Mid (db) 42.0 Low (db) 40.0 Height (mm) 430 External Dimensions Width (mm) Depth (mm) Total weight (kg) Connecting Gas side (mm) ø9.5 ø12.7 piping Liquid side (mm) ø6.4 Drain port (Nominal dia.mm vinyl chloride tube)

66 66 MMD-VN502HEXE x 30 oval hole (Hangling bracket) EA (Exhaust Air) Outdoor side RA (Return Air) Indppr Side OA (Outdoor Air) SA (Supply Air) Power supply wire intake Heat exchange element Filter Motors, ( Fans, Maintenance space ( 600 Magnetic valve Decompression magnetic valve (Humidification element Maintenance space 454 ( Water inlet connecting port (R1/2) Inspection opening 600 x 600 Duct size (Nominal Diameter): Drain pipe connecting port (VP25) Refrigerant pipe connecting port (Liquid) 6.4 Refrigerant pipe connecting port (Gas) 9.5 (Unit: mm) MMD-VN802HEXE to VN1002HEXE/ x 30 oval hole (Hangling bracket) EA (Exhaust Air) Outdoor side OA (Outdoor Air) 200 RA (Return Air) Indppr Side SA (Supply Air) Power supply wire intake 600 Heat exchange element Filter Motors, ( Fans, Maintenance space Magnetic valve Decompression magnetic valve (Humidification element Maintenance space ( 454 ( Water inlet connecting port (R1/2) Inspection opening 600 x Duct size (Nominal Diameter): Drain pipe connecting port (VP25) Refrigerant pipe connecting port (Liquid) 6.4 Refrigerant pipe connecting port (Gas) 12.7 (Unit: mm) Options Drain pump kit TCB-DP31HEXE

67 67

68 68 VN-M150HE to VN-M350HE EA(Exhaust Air) Outdoor side 1050 RA(Return Air) Indoor side Connecting Diagram 80 Earth Terminal OA(Outdoor Air) SA(Suppiy Air) Power supply wire intake 600 or more 150~ Oval hole(hanging Bracket) Inspection Opening or more Duct size (Nominal Diameter): 200 Heat Exchange Element Filter Motor,Fans Maintenance Space (Unit: mm) VN-M500HE, VN-M650HE EA(Exhaust Air) Outdoor side 1050 RA(Return Air) Indoor side Connecting Diagram 80 Earth Terminal OA(Outdoor Air) SA(Suppiy Air) Power supply wire intake 600 or more 150~250 Duct size (Nominal Diameter): Heat Exchange Element Filter Motor,Fans Maintenance Space Oval hole(hanging Bracket) Inspection Opening or more (Unit: mm) VN-M800HE, VN-M1000HE or more ~250 EA(Exhaust Air) Outdoor side OA(Outdoor Air) 1099 Indoor side 200 RA(Return Air) SA(Suppiy Air) Oval hole(hanging Bracket) Inspection Opening or more Connecting Diagram 85 Power supply wire intake Earth Terminal Duct size (Nominal Diameter): 250 Heat Exchange Element Filter Motor,Fans Maintenance Space (Unit: mm) VN-M1500HE, VN-M2000HE or more ~250 EA(Exhaust Air) Outdoor side OA(Outdoor Air) 1099 Indoor side 200 RA(Return Air) SA(Suppiy Air) Oval hole(hanging Bracket) Inspection Opening or more Connecting Diagram Power supply wire intake Duct size (Nominal Diameter): 250 Heat Exchange Element Filter Motor,Fans Maintenance Space (Unit: mm)

69 69 Indoor unit Parts Name Model Name Applied Model Notes Remarks Ceiling panel RBC-U31PG(W)-E Required accessory Fresh air inlet box TCB-GB1602UE For fresh air intake by using the knockout hole of fresh air filter chamber. Use with (dia.=100 mm) TCB-GFC1602UE 4-way air discharge Fresh air filter chamber TCB-GFC1602UE For fresh air inlet box MMU-AP***4HP-E cassette type For easy fresh air intake by using the knockout hole of indoor unit. Auxiliary fresh air flange TCB-FF101URE2 (dia.=100 mm) Spacer for height TCB-SP1602UE Height=50 mm Air discharge direction kit TCB-BC1602UE Air direction charge by cutting off air discharge port (3 pcs.) Compact 4-way Ceiling panel RBC-UM11PG(W)E Required accessory cassette ( ) MMU-AP***4MH-E For easy fresh air intake by using the knockout hole of indoor unit. type Auxiliary fresh air flange TCB-FF101URE2 (dia.=100 mm) RBC-UW283PG(W)-E MMU-AP0072 to 0152WH Ceiling panel RBC-UW803PG(W)-E MMU-AP0182 to 0302WH Required accessory RBC-UW1403PG(W)-E MMU-AP0362/0482/0562WH TCB-LF283UW-E MMU-AP0072 to 0152WH Use with TCB-FC283UW-E Dust collecting effect: 50% 2-way air discharge Super long life filter TCB-LF803UW-E MMU-AP0182 to 0302WH Use with TCB-FC803UW-E (Weight method) cassette type TCB-LF1403UW-E MMU-AP0362/0482/0562WH Use with TCB-FC1403UW-E TCB-FC283UW-E MMU-AP0072 to 0152WH Filter chamber TCB-FC803UW-E MMU-AP0182 to 0302WH For super long life filter TCB-FC1403UW-E MMU-AP0362/0482/0562WH Auxiliary fresh air flange TCB-FF151US-E MMU-AP***2WH For fresh air intake by using the knockout hole of indoor unit. RBC-UY136PG MMU-AP***4YH-E Required accessory Ceiling panel RBC-US21PGE Required accessory 1-way air discharge Front air discharge unit TCB-BUS21HWE cassette type MMU-AP***4SH-E For easy fresh air intake by using the knockout hole of indoor unit. Auxiliary fresh air flange TCB-FF101URE2 (dia.=100 mm) TCB-SF56C6BPE MMD-AP0076 to 0186BHP-E Concealed duct Spigot shaped flange TCB-SF80C6BPE MMD-AP0246/0276/0306BHP-E type TCB-SF160C6BPE MMD-AP0366/0486/0566BHP-E Long Life Filter Kit TCB-LK801D-E MMD-AP0186/0246/0276HP-E TCB-LK1401D-E MMD-AP0366/0486/0586HP-E Spigot Shaped Flange TCB-SF80C6BPE MMD-AP0186/0246/0276HP-E TCB-SF160C6BPE MMD-AP0366/0486/0586HP-E Concealed duct Auxiliary fresh air flange TCB-SF160C6BPE MMD-AP***6HP-E high static pressure type High-efficiency filter 65 TCB-UFM3DE MMD-AP0724/0964H-E Dust collecting effect: 65%(NBS Colorimentric method) High-efficiency filter 90 TCB-UFH7DE MMD-AP0724/0964H-E Dust collecting effect: 90%(NBS Colorimentric method) Long life prefilter TCB-PF3DE MMD-AP0724/0964H-E Dust collecting effect: 50%(Weight method) Filter chamber TCB-FCY100DE MMD-AP0724/0964H-E For high-efficiency filter or long life prefilter Drain pump kit TCB-DP32DE MMD-AP0724/0964H-E Stand-up 330 mm or less (from bottom face of ceiling) Slim duct type Auxiliary fresh air flange TCB-FF101URE2 MMD-AP***4SPH-E For fresh air intake by using the knockout hole of indoor unit. (dia.=100 Ceiling type MMC-AP0157/0187HP-E Stand-up 600 or less Use with TCB-KP13CE Drain pump kit TCB-DP31CE MMC-AP0247 to 0567HP-E (from bottom face of ceiling) Use with TCB-KP23CE TCB-KP13CE MMC-AP0157/0187HP-E Elbow piping kit Needed when drain pump kit is used TCB-KP23CE MMC-AP0247 to 0567HP-E Air to Air Heat Exchanger with DX-coil Drain pump kit TCB-DP31HEXE MMD-VN502 to 1002HEXE Stand-up 330 mm or less (from bottom face of ceiling) High-efficiency filter 65 TCB-UFM3DE MMD-AP0721/0961HFE Dust collecting effect: 65% Use with TCB-PF3DE TCB-UFM4D-1E MMD-AP0481HFE (NBS Colorimemtric method) Use with TCB-PF4D-1E High-efficiency filter 90 TCB-UFH7DE MMD-AP0721/0961HFE Dust collecting effect: 90% Use with TCB-PF3DE Fresh air intake indoor unit type TCB-UFH8D-1E MMD-AP0481HFE (NBS Colorimemtric method) Use with TCB-PF4D-1E TCB-PF3DE MMD-AP0721/0961HFE Dust collecting effect: 50% Long life prefilter TCB-PF4D-1E MMD-AP0481HFE (Weight method) TCB-FCY51DFE MMD-AP0481HFE Filter chamber For high-efficiency filter or long life prefilter TCB-FCY100DE MMD-AP0721/0961HFE Drain pump kit Drain pump kit MMD- Stand-up 330 or less (from bottom face of ceiling) Indoor unit accessories

70 70 1) Accessory for 4-way air discharge cassette type: combination pattern Combination Pattern Ceiling panel Fresh air inlet box + Fresh air filter chamber Fresh air filter chamber Auxiliary fresh air flange Spacer for height adjustment Air discharge direction kit 1 Ceiling panel OK OK OK OK OK 2 Fresh air inlet box + Fresh air filter chamber OK OK OK 3 Fresh air filter chamber OK OK OK OK 4 Auxiliary fresh air flange OK OK OK OK OK 5 Spacer for height adjustment OK OK OK OK 6 Air discharge direction kit OK OK OK OK OK

71 71 Remote controllers Air-condi oning Management System on site Analog I/F (DCvoltage) TCB-IFCB641TLE Open Network System LonWorks Modbus TCB-IFLN642TLE/TCB-IFLN642UL RS485 TCB-IFMB641TLE BACnet RS485 TCS-Net Relay Interface BMS-LSV4E TCC-LINK BMS-LSV10E BACnet Server RS485 Energy monitoring Relay I/F Power Meter Touch-screen Controller BMS-CT5120E Digital I/O Relay I/F I/O Device Smart BMS Manager BMS-SM1280HTLE BMS-SM1280ETLE RS485 TCC-LINK Energy monitoring Relay I/F BMS-IFWH5E Power Meter Intranet Digital I/O Relay I/F BMS-IFDD03E RS485 I/O Device Central Remote Controller ON-OFF controller TCB-CC163TLE2 Schedule mer TCB-EXS21TLE Central remote controller BMS-CM1280TLE 1.LonWorks : Registered trademark by Echelon corpora on. 2.BACnet : ANSI/ASHRAE , A data Communica on Protocol for Building Automa on and Control Network. 3.Modbus : Registered trademark by Schneider E.

72 72

73 73 Wired remote controller Lite-Vision plus Remote Controller RBC-AMS51E-ES RBC-AMS51E-EN Wired remote controller with a built in 7-day timer-featuring a new multi-language, LCD display with backlight, energy saving options and a return back function. Possibility to set and display the room name to easily set-up and monitor the working parameter. New modern and desirable controller design with menu driven display. Save mode by schedule timer to optimise energy consumption. Room temperature display always available. Two Hot Keys (F1, F2) for easy operation of air conditioner functions. Easy to read layout including display of indoor unit model name and serial number. Built-in backup power. Settings are kept in memory up to 72 hours in case of power failure. Remote TA sensor available in controller. Can be connected to a single indoor unit or a group of up to 8 indoor units. Standard Remote controller RBC-AMT32E Standard wired remote controller can be connected to a single indoor unit or a group of up to 8 indoor units. Power save operation limits the greatest current value.the remote controller allows error to be displayed while the protective device works or a error occurs. Remote controller with weekly timer (7-day timer function) RBC-AMS41E Clock display Schedule timer: Possible to program schedule timer (7-day timer) function Possible to program 8 functions for each day of the week * The following items can be set in program: operation time, operation start/stop, operation mode, temperature setting, restriction on button operation Simple wired remote controller RBC-AS41E Start/Stop Temperature setting Check code display Wireless remote controller Wireless remote controller kit & sensor unit (receiver unit) Start/Stop Changing mode Temperature setting Air changing Timer function Either ON time or OFF time or CYCLIC can be set how many 30 min. later ON or OFF is operated. Control by 2 remote controllers is available. Two wireless remote controllers can operate one indoor unit. The indoor unit can then be operated separately from the two locations. Check code display * The wireless remote control cannot be connected to concealed duct high static pressure type. RBC-AX33CE Integral receiver (For ceiling) (MMC-AP 7HP-E) (MMU-AP 4SH-E) RBC-AX32U(W)-E Integral receiver (For 4-way air discharge cassette) (MMU-AP 4HP-E) TCB-AX32E2 Stand alone receiver (For 4-way air discharge cassette, compact 4-way cassette (600 x 600), 2-way air discharge cassette, ceiling, concealed standing, 1-way discharge cassette (MMU-AP ***4YH-E/SH-E) RBC-AX23UW(W)-E Integral receiver (For 2-way air discharge cassette) (MMU-AP 2WH)

74 74 Central remote controller Central remote controller BMS-CM1280TLE Operation Individual operation of 128 indoor units available Return Back Operation Weekly Schedule Operation* (ON/OFF) * Schedule timer necessary Monitoring Zone setting (64 zones x 2) Individual unit operation mode operation restriction Alarm display Control input Status output ON-OFF controller TCB-CC163TLE2 Individual control of up to 16 indoor units. Setting of simultaneous ON/OFF 3times per day combined with the weekly timer. Schedule timer TCB-EXS21TLE Schedule timer mode 6 programmings per day Enabling 8 groups to be programmed A maximum of 64 indoor units can be controlled A maximum of 100 hours back-up power supply Weekly timer mode 7 types of weekly schedule and 3 programmings per day Other Remote sensor TCB-TC41LE Install this sensor when outside air has been introduced or when overcooling and overheating are to be minimised. Wired remote controller for air to air heat exchanger NRC-01HE Up to 8 units of the Air to Air Heat Exchanger can be operated using this remote controller. Control by 2 remote controllers is available. Two remote controllers can operate a single Air to Air Heat Exchanger. Air conditioning units may be controlled in addition to controlling the Air to Air Heat Exchanger. Central control allows linked ON/OFF operation of air conditioner and Air to Air Heat Exchanger. Central control can be set to allow standalone operation of the Air to Air Heat Exchanger. Switchable ventilation modes (Automatic/Air to Air/Normal) Switchable ventilation air volume (Extra-high/High-Low)

75 75 Building management systems SMART MANAGER / SMART MANAGER WITH DATA ANALYSER Power unit Power Supply 1-phase V 50Hz 1-phase 220V 60Hz TCC-LINK TCC-LINK Local Supply RS-485 SMART BMS MANAGER BMS-SM1280HTLE or SMART BMS MANAGER WITH DATA ANALYSER BMS-SM1280ETLE SMMS-e MiNi-SMMS Interface Energy Monitoring Relay Interface Digital I/O Relay Interface Touch screen controller Interfaces TCC-LINK RS-485 Ethernet Max. 12 Max. 128 units units Max. 512 units TOUCH SCREEN CONTROLLER BMS-CT5120E Interface Energy Monitoring Relay Interface Digital I/O Relay Interface

76 76 SMART BMS MANAGER BMS-SM1280HTLE Web browser control software List View available - Displays all indoor units in one screen Set View available - Shows basic indoor unit settings on main screen Advanced operation and master schedule functions available Advanced operation & master schedules can be set on a calendar Up to 4 concurrent users can be connected Up to 32 user accounts can be programmed with levels of access (at least 1 must be administrator level) Energy monitoring and billing functions available Additional digital I/O device available Thin controller and separate power supply unit enables easy installation. SMART MANAGER WITH DATA ANALYSER BMS-SM1280ETLE Energy monitoring display 3D energy view Daily energy view Touch screen controller Using the touch screen controller provides a clear display and enables easy operation. A maximum of 512 units / groups are controllable. Energy monitoring and billing application Power meter interface, power meter locally supplied Energy Monitoring relay I/F (BMS-IFWH5E) TOUCH SCREEN CONTROLLER BMS-CT5120E Power meter (Local Supply) 1 kwh/pulse or 10 kwh/pulse (Pulse duration 50 to 1000 ms) (Maximum 8 power meters per interface) FEATURES Relay Interface BMS-IFWH5E For Energy Monitoring Relay Interface BMS-IFDD03E For Digital I/O Relay Interface BMS-IFLSV4E For TCS-NET Icon display Return back function Save & demand control for outdoor unit Ventilation unit control & monitoring Setting temp. range control Setting temp. shift

77 77 Open network systems BACnet system BACnet / IP Local supply BMS-STBN10E RS-485 TCC-LINK Intelligent server (BACnet server software required) BMS-LSV10E TCS-NET Relay Interface BMS-IFLSV4E LonWorks TCC-LINK Local supply LN Interface TCB-IFLN642TLE Modbus Local supply TCC-LINK RS-485 Modbus Interface TCB-IFMB641TLE

78 78 Intelligent Server BMS-LSV10E BACnet The BACnet system operates in conjunction with the BACnet. Server uses object signals to provide the following functions: Control ON/OFF Temperature setting Fan speed Monitoring ON/OFF Operation mode Temperature setting Room temperature Local remote controller : permit / prohibit BACnet Server Software BMS-STBN10E Relay Interface BMS-IFLSV4E For TCS-NET LonWorks LN Interface The LonWorks interface manages the MiNi-SMMS air conditioning system as a Lon device to communicate with the custormer s Building Management System and to monitor operational status. A maximum of 64 units / groups are controllable per interface. SNVT signal Signals and provides the following functions: LN Interface TCB-IFLN642TLE Control ON/OFF Temperature setting Fan speed Monitoring ON/OFF Operation mode Temperature setting Room temperature Local remote controller : permit / prohibit Modbus Interface TCB-IFMB641TLE Modbus The Modbus interface manages the MiNi-SMMS air conditioning system as a Modbus device to communicate with the custormer s Building Management System. Accessible to 64 units / groups per one TCB-IFMB641TLE, 15 TCB-IFMB641TLEs on one Modbus Master (prepared by user). Signals and provides the following functions: Control ON/OFF Temperature setting Fan speed 1. LonWorks : Registered trademark Echelon corporation. 2. BACnet : ANSI/ASHRAE , A data Communication Protocol for Building Automation and Control Networks. 3. Modbus is a registered trademark of Schneider E. Monitoring ON/OFF Operation mode Temperature setting Room temperature Local remote controller : permit / prohibit

79 79 Application controls TCB-PCDM4E Size: (mm) Power peak-cut control Feature The upper limit capacity of the outdoor unit is restricted based on the outdoor power peak selected setting. Function Two control settings are selectable by setting SW07 on the interface P.C. board on the outdoor unit. TCB-PCMO4E Size: (mm) Snowfall fan control Feature The upper limit capacity of the outdoor unit is restricted based on the outdoor power peak selected setting. External master ON/OFF control Feature The outdoor unit starts or stops the system. Night operation (Sound reduction) control Feature Sound level can be reduced by restricting the compressor and fan speeds. Operation mode selection control Feature This control can restrict the selectable operation modes.

80 80 TCB-PCIN4E Size: (mm) Error/Operation output control Feature Enables external output of error and operation signals. Compressor operation output Feature Enables external signal output for each compressor that is in operation within any given outdoor unit. This feature provides a practical method for calculating total operating times for each compressor. Operating rate output Feature External output of system operating rates enables remote monitoring of operating conditions. TCB-IFCB-4E2 Size: (mm) Remote location ON/OFF control box Feature Start and stop of the air conditioner is possible by an external signal and indication of operation/ alarm externally. Operation Monitoring ON/OFF status (for indoor unit) Alarm status (system & indoor unit stop) ON/OFF command Air conditioner can be turned ON/OFF by the external signals. The external ON/OFF signals will initiate the signals shown below. Display Interface Remote Controller

81 81 Safety precautions General Purpose Interface General purpose interface TCB-IFCG1TLE Modbus control Modbus I/F Optional devices TCC-LINK Concept Controls the operation status of each indoor unit. ON/OFF control of peripheral equipment via the relay point of Toshiba's BMS. (1pt only) Standard function Central remote controller and Building Management System devices can control ON/OFF function via digital I/O ports. (HA) Daiseikai Sensors Switches Pump/ motor Lights Optional function Control using the following channels: 4-channel relay control, 6-channel digital input, 2-channel analog voltage input and output, and 2-channel temperature measurement functions via Modbus I/F. Analog Interface Analog interface TCB-IFCB640TLE Concept Provides access to 64 indoor units. Does not require special network knowledge. Temperature indicated controller 0-10V DC Rotary encoder TCC-LINK Can control each indoor unit on TCC-LINK, (on/ position), and monitor status based on 0-10V DC voltage input. Enables relay control and status monitoring of general-purpose I/F TCB-IFCG1TLE.

82 82 Air Conditioning for Small and Medium-size Buildings

83 83 Defining a HIGHER standard The all-new MiNi-SMMS air conditioner lineup lets you cool or warm as many as 12 *1 rooms with a single system. Outdoor units ranging 4 to 12HP, offer best class energy savings, installation flexibility and quiet operation, plus with 13 indoor units to choose from, the MiNi-SMMS makes a perfect solution for small shops and office buildings. *1: 3-phase 12HP outdoor unit The all-new MiNi-SMMS 10 and 12HP models featuring 3-phase power supply for small and mid-size installations HIGHER ENERGY SAVINGS MiNi-SMMS achieves world-class COP of 4.40 *2 and EER of 3.60 *2 thanks to an integrated combination of Toshiba s more advanced twin rotary compressor, vectorcontrolled inverter and heat exchanger technologies. HIGHER COMFORT AND EASE A single outdoor unit is powerful enough to accommodate up to 12 *1 independently controlled interior units, delivering ideal quiet comfort to every room. *2: 3-phase 6HP outdoor unit

84 84 HIGHER INSTALLATION FLEXIBILITY MiNi-SMMS s small footprint allows for fast and easy installation. Furthermore, a maximum piping extension of 180m *3 affords unprecedented configuration flexibility, making this unit ideal for a wide variety of applications. *3: 3-phase 10 and 12HP outdoor units

85 85 HIGHER ENERGY SAVINGS Industry-leading energy savings Energy-efficient performance for greater eco-consciousness Adopting the highly efficient DC twin-rotary compressors and advanced vector-controlled inverters realize a EER of 5.71 (under 50% partial load, 4HP). Greater operating performance is now possible when operating under a constant load HP EER 8HP HP HP COP 8HP HP Rated 50% load 4HP: MCY-MAP0401HT/HT2D 8HP: MCY-MAP0804HT8/HT7 12HP: MCY-MHP1204HT8 *Rated conditions Cooling : Indoor air temperature 27 o C DB / 19 o C WB, Outdoor air temperature 35 o C DB Heating : Indoor air temperature 20 o C DB, Outdoor air temperature 7 o C DB / 6 o C WB

86 86 Toshiba's unique energy-efficient air conditioning innovations and technologies deliver high energy savings. DC fan motor Highly efficient DC motor Sine wave drive Vector-controlled inverter The inverter boosts efficiency by controlling R410A and a twin-rotary DC compressor. Heat exchanger High-efficiency R410A heat-transfer tube Configuration of the finned heat-transfer tube Bat wing fan High-pressure low-volume fan Smooth sine curve realizes higher efficiency and less noise. Vector IPDU control changes the motor current wave to a smooth sine pattern so that noise emitted from the drive units is greatly reduced. Twin-rotary DC compressor Increased, wide range efficiency is realized. Efficient circuit built-in; new PIM DC driven motor with rare-earth magnet - Compact - Higher efficiency - Higher power motor torque The bat wing fan realizes low sound level. Precise manufacturing technology in the compression parts - Higher efficiency (in wide range) - Higher reliability

87 87 Our MiNi-SMMS has the lowest seasonal power consumption and the highest energy conservation. Why our systems make a big difference to your electricity bill even though the COP is virtually the same! Your electricity bill (seasonal power consumption) is highly dependent on fluctuating outside air temperature. However, COP is calculated at only two outside temperature points, 7 C (heating rating) and 35 C (cooling rating) which is often not representative of actual conditions. To estimate energy savings, you should factor the actual outside air temperature generation time into your seasonal power consumption. Annual generation time (hours/year) ) Outside air temperature of 35 C (JIS standard conditions for calculating COP) occurs only 4 or so hours a year! Outside air temperature conditions for calculating COP during cooling (from 8:00 to 21:00 in Tokyo) This difference is the reason for actual energy Partial load range *Most frequent operation Standard range Total efficiency of compressor (%) rotary type Frequency of compressor (rps) Comparison of DC twin-rotary and conventional rotary compressors

88 88 Mechanism of improving COP Improves both COP and reliability Amount of oil released from compressor reduced Oil separator unnecessary Oil separator: This component separates the oil and refrigerant that are released from the compressor, and returns the oil to the compressor. What accounts for the improvement in COP? Previous multi-system outdoor units like the SMMS required both an oil separator and a power source for the oil separator, but this system needs neither, thus improving COP. DC twin-rotary compressor advantage MiNi-SMMS uses twin-rotary inverter compressors that deliver a more stable, energy-efficient performance through their full range of compressor rotation when compared to scroll type compressors. Scroll compressors too can achieve high-efficiency operation, but only within a narrow range. As VRF systems require a wide range of capacity, twin-rotary compressors are the ideal choice.

89 89 HIGHER COMFORT AND EASE A single outdoor unit is powerful enough to accommodate up to 12 * independently controlled interior units, delivering ideal quiet comfort to every room. *3-phase 12HP outdoor unit Comfort and wide application control The ON-OFF controller makes it easy to manage all indoor units from a single location. ON-OFF controller TCB-CC163TLE2 All ON-OFF button Indoor Unit Outdoor Unit Smart Manager for remote management By connecting a PC to the system via Ethernet, temperatures and operation in each room can be remotely monitored and controlled. Furthermore, daily, weekly, and monthly schedules can be set for automated operation. MiNi-SMMS User TCC-LINK LINE Ethernet SMART MANAGER BMS-SM1280HTLE Administrator User

90 90 PMV kit for quieter operation An optional PMV kit allows quieter placement by efficiently reducing the sound made by the refrigerant in the piping. The PMV function is normally inside the indoor unit, and is the cause of most of the noise from the indoor unit. PMV kit (optional part) If the PMV function is removed from the indoor unit, noise can be significantly reduced.

91 91 Bat wing fan Fan blade design plays a significant part reducing noise and vibration. Anti-eddy projections and reverse-arc shaped wings reduce air resistance resulting in low operating noise of the outdoor unit. 1-phase outdoor unit Sound Pressure level Conventional fan -2dB 1 Bat wing fan 2 Standard Air Volume n Air Volume At same air volume, sound is reduced by 2 db. 1 2 Anti-eddy projections Minimizes the generation of large eddies. Reverse-arc-shaped wing Reduces rear turbulence due to less pressure loss..

92 92 Night operation (sound reduction) control (with optional PC Board (TCB-PCMO4E) and locally supplied timer/switch) The unit also comes with a nighttime low-noise mode, which reduces operating noise at the programmed activation time. (Timer or switch to be locally obtained.) 1-phase outdoor unit Operation control Normal Night 4HP Cooling 49dB(A) 46dB(A) 5HP Cooling 50dB(A) 46dB(A) 6HP Cooling 51dB(A) 47dB(A) 3-phase outdoor unit Operation control Normal Night 6HP Cooling 58dB(A) 50dB(A) 8HP Cooling 58dB(A) 50dB(A) 10HP Cooling 58dB(A) 50dB(A) 12HP Cooling 61dB(A) 50dB(A) *Sound pressure level: db(a) Day Night

93 93 HIGHER INSTALLATION FLEXIBILITY Small footprint The outdoor unit has a small physical footprint of only 0.29m 2 and 0.39m 2, taking up as little space outside as possible. 3-phase 10, 12HP 1-phase 4, 5, 6HP 3-phase 6, 8HP 1.34m 1.54m 1.83m 0.9m 0.32m 0.9m 0.32m 0.29m m m 0.39m m MiNi-SMMS is suitable for balconies The outdoor unit is compact and expels exhaust air to the side, so it can be installed even in limited spaces as shown.

94 94 Shortest route design by free branching Header branching after header branching Outdoor unit Combination of line and header branching is highly flexible, allowing the shortest route possible thereby saving on installation time and costs. Header Header branching after header branching is only available with Toshiba systems. Indoor unit Header Header branching after line branching Outdoor unit Header Indoor unit Maximum piping length with PMV kit Extended refrigerant piping possibilities are possible even with the optional PMV kit installed. 3-phase 6 and 8HP outdoor units have a maximum pipe extension of 100m, regardless of PMV kits used. 3-phase 10 and 12HP outdoor units have a maximum pipe extension of 180m, and 150m when equipped with PMV kits. On 1-phase outdoor units, piping lengths will differ when PMV kits are used, as shown below. 1-phase outdoor unit When PMV kit is not used When PMV kit is used (Outdoor unit higher than indoor units) (Outdoor unit higher than indoor units) H L1 L2 a b c b Not used 180 Piping length Maximum pipe extension (Liquid pipe, real length) Piping section: L1+L2+a+b+c Used 150 H L1 L2 a b c b c a L2 L1 H Farthest piping length (equivalent length) Piping section: L1+L2+c Height difference Height between indoor and outdoor units (Outdoor unit higher than indoor units) Piping section: H c a L2 L1 H (Outdoor unit lower than indoor units) 20 Height between indoor and outdoor units (Outdoor unit lower than indoor units) Piping section: H 20 PMV kit (Outdoor unit lower than indoor units)

95 95 Maximum piping length (3-phase outdoor units) With a maximum piping length of up to 120m *, the the outdoor unit can be placed far away and out of sight. Main piping length 30m /65 m *: 3-phase 10 and 12HP outdoor units Furthest equivalent piping length 60m/120m (6, 8HP/10, 12HP) Maximum height difference (3-phase outdoor units) A maximum height difference of 15m means a single unit can supply indoor units on two or even three floors. Height between indoor units 10m Maximum height between outdoor and indoor unit 15m

96 96 More Attractive Features Reducing peak power consumption levels (optional) An optional circuit board (TCB-PCDM4E) can be used to limit operation to specified setting ranges (Standard and Extended modes), controlled by the demand signal status. System operation is confined to a range that does not exceed thresholds. Operation example 100% Operation limited by setting Mode Standard (2-steps) Pattern A B Selectable Capacity 100%(Normal) / 0%(Stop) 100%(Normal) / Up to 60% Setting value Extended (4-steps) A B 100%(Normal) / Up to 80% / Up to 60% / 0%(Stop) 100%(Normal) / Up to 85% / Up to 75% / Up to 60% Note: The above limitations do not apply at startup after heating operation has been turned off, during defrosting, and when heating operation is starting after defrosting finishes. Demand control on Demand control off External device

97 97 Outdoor units line-up 1-phase model Capacity 4HP 5HP 6HP Model Name 50 Hz (MCY-) MHP0404HT-SG MHP0504HT-SG MHP0604HT-SG Cooling capacity* (kw) Power supply 1-phase 2 wires 50Hz V 3-phase model Capacity 6HP 8HP 10HP 12HP Model Name 50 Hz (MCY-) MAP0604HT8 MAP0804HT8 MHP1004HT8 MHP1204HT8 Cooling capacity* (kw) Power supply 3-phase 4 wires 50Hz 380V-415V 3-phase 4 wires 50Hz 380V-415V *Rated conditions Cooling : Indoor air temperature 27 o C DB / 19 o C WB, Outdoor air temperature 35 o C DB Heating : Indoor air temperature 20 o C DB, Outdoor air temperature 7 o C DB / 6 o C WB

98 98 Optimal refrigerant control When a multiple number of indoor units are connected, an insufficient or excess amount of refrigerant may be supplied to indoor units depending on the difference in length of the connection pipe from the outdoor unit. This is because pressure loss and heat leaks occur as the refrigerant travels through the pipes, resulting in incorrect amounts of refrigerant being supplied to the indoor units. Optimal refrigerant control uses a multiple number of refrigerant sensors to detect the air-conditioning status of each indoor unit and precisely controls the capacity (amount of refrigerant) to eliminate variations. Outdoor unit Pulse motor valve D A B C Indoor unit TC2 Refrigerant sensor (In) Heat exchanger TC1 Refrigerant sensor (Out) The surplus represented by (A) is diminished. Capacity The surplus represented by (B) is diminished and the deficiency represented by (C) is compensated for. The surplus represented by (A) is diminished and the deficiency represented by (D) is compensated for. Target value (A) (B) (C) (D)

99 99 Branching joints and headers Y-shape branching joint Branch headers Appearance (4-branch headers) Model name (RBM-) BY55E (Below 6.4HP) BY105E ( 6.4HP or more) HY1043E (Max. 4 branches) HY1083E (Max. 8 branches) PMV kit PMV kit Appearance Model name (RBM-) PMV0362E PMV0902E Indoor unit capacity type 007/009/012 type 015/018/024 type

100 100 1-phase model Equivalent HP 4HP 5HP 6HP Model name MCY-MHP0404HT-SG MCY-MHP0504HT-SG MCY-MHP0604HT-SG Outdoor unit type Power supply Inverter unit 1-phase 50Hz V / 1-phase 60Hz 220V Capacity 100% (kw) Power consumption (kw) Cooling *1 EER (Energy Efficiency Ratio) Capacity 100% Capacity 80% Capacity 50% Capacity 100% (kw) Power consumption (kw Heating *1 COP (Coefficient of Performance) Capacity 100% Capacity 80% Capacity 50% External dimensions (Height / Width / Depth) (mm) 1235 / 990 / 390 Total weight (kg) 115 Compressor Motor output (kw) Fan unit Motor output (kw) Air volume (m 3 /h) Connecting port dia. Gas side (OD) (mm) Liquid side (OD) (mm) 9.5 Max. pipe extension (Liquid pipe, real length) (m) 90 (75 *2 ) Refrigerant piping Specifications Max. pipe length (Real length) (m) 50 (40 *2 ) Max. pipe length (Equivalent length) (m) 60 (50 *2 ) Max. height between indoor and outdoor units (m) Outdoor unit higher than indoor unit: 15 Outdoor unit lower than indoor unit: 15 Max. no. of connected indoor units Sound pressure level (Cooling/Heating) *3 (db(a)) 50/52 51/54 52/55 NEA Green ticks *1 Rated conditions Cooling : Indoor air temperature 27 o C DB / 19 o C WB, Outdoor air temperature 35 o C DB Heating : Indoor air temperature 20 o C DB, Outdoor air temperature 7 o C DB / 6 o C WB The standard pipe means that equivalent piping length of 7.5 m and standard 0 m piping height difference. *2 When PMV kit is used *3 Sound pressure levels measured in an anechoic chamber in accordance with JIS B 8616.

101 101 3-phase model Technical specifications Equivalent HP 6HP 8HP 10HP 12HP M o d e l n a m e 50 H z (MCY-) MAP0604HT8 MAP0804HT8 MHP1004HT8 MHP1204HT8 Outdoor unit type Inverter unit Power supply 3-phase 4 wires 50Hz V 3-phase 4 wires 50Hz V Capacity 100% (kw) Power consumption (kw) Capacity 100% Cooling *1 Efficiency (ikw/rt) EER (Energy Efficiency Ratio) Capacity 80% Capacity 50% Capacity 100% Capacity 80% Capacity 50% External dimensions (Height / Width / Depth) (mm) 1540 / 900 / / 990 / 390 Total weight (kg) Compressor Motor output (kw) Fan unit Motor output (kw) Air volume (m 3 /h) Connecting port dia. Gas side (OD) (mm) Liquid side (OD) (mm) Max. pipe extension (Liquid pipe, real length) (m) 100 (100) *2 180 (150) *2 Refrigerant piping Specifications Max. pipe length (Real length) (m) 50 (50) *2 100 (65) *2 Max. pipe length (Equivalent length) (m) 60 (60) *2 120 (80) *2 Max. height between indoor and outdoor units (m) Outdoor unit higher than indoor unit: 15 Outdoor unit lower than indoor unit: 15 Max. no. of connected indoor units Sound pressure level (Cooling) *3 (db(a)) *1 Rated conditions Cooling : Indoor air temperature 27 o C DB / 19 o C WB, Outdoor air temperature 35 o C DB *2 When PMV kit is used *3 Sound pressure levels measured in an anechoic chamber Anti-Corrosion protection model : MCY-MAP****HT8ZG, MCY-MAP****HT7ZG, except 10HP, 12HP.

102 102

103 103 3-phase model : MCY-MAP0604HT8, MAP0804HT8 (50Hz) lower piping Diameter of refrigerant pipe Model name Gas side Liquid side MCY-MAP0604HT8/HT7 O/ 19.1 O/ 9.5 MCY-MAP0804HT8/HT7 O/ 19.1 O/ 9.5

104 104 Outdoor drawings 3-phase model : MCY-MHP1004HT8, MHP1204HT8 (50Hz) Knockout for lower piping Diameter of pipe connecting port Diameter of connecting pipe Liquid side Gas side Liquid side Gas side *1 MCY-MHP1004HT8 ø 12.7 ø 25.4 ø 12.7 ø 22.2 MCY-MHP1204HT8 ø 12.7 ø 25.4 ø 12.7 ø 25.4 *1 The diameter of ball valve connecting port on the outdoor unit is 25.4, and therefore please use the accessory joint for installation.

105 105

106 CSL-July-2016

Simultaneous. Heating and Cooling Solution for Large Buildings. Air Conditioning for large buildings

Simultaneous. Heating and Cooling Solution for Large Buildings. Air Conditioning for large buildings Simultaneous Heating and Cooling Solution for Large Buildings Air Conditioning for large buildings Toshiba solutions Index Introduction 3 SHRM-e 4 Energy saving 6 Individual temperature control 8 Soft

More information

Index. Toshiba Solutions. Absolute comfort

Index. Toshiba Solutions. Absolute comfort 2 3 Index Introduction 3 Industry leading energy savings 6 New smart & sensitive VRF control 10 Industry leading layout flexibility 14 Other features 18 Outdoor units Outdoor units line-up 20 Outdoor units

More information

MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL

MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL 2 Toshiba solutions residential, light commercial and larger commercial buildings. Residential indoor units are designed to blend perfectly with all interiors

More information

Air Conditioning For Large Buildings

Air Conditioning For Large Buildings Air Conditioning For Large Buildings Index Introduction 2 Line-up 16 Outdoor SMMS-i specifications 20 Indoor 4-way cassette 22 Compact 4-way cassette 24 2-way Air Discharge Cassette Type 26 1-way cassette

More information

Blending Commercial and Residential. MiNi VRF

Blending Commercial and Residential. MiNi VRF Blending Commercial and Residential MiNi VRF Toshiba Solutions Delivering Absolute Comfort Toshiba offers a solution for all applications: residential, light commercial and larger commercial buildings.

More information

Business. The business range. The most advanced solutions for larger buildings.

Business. The business range. The most advanced solutions for larger buildings. Business The business range The most advanced solutions for larger buildings. 81 82 Business VRF. The freedom of choice Variable refrigerant flow offer the advantages of direct expansion linked to inverter

More information

Product Launch SHRMi

Product Launch SHRMi Product Launch SHRMi What s SHRM i SMMS i (High Efficiency & Reliability) Simultaneous Operation by heat recovery + = SHRM i meets various customers needs! Refrigerant flow, cooling Liquid pipe Flow selector

More information

Single Fan MiNi VRF Apartment Ready

Single Fan MiNi VRF Apartment Ready SINGLE FAN MiNi VRF What you ll find inside: Technology Features Controllers Product specifications Single Phase Energy efficient Heating & cooling Single Fan MiNi VRF Apartment Ready SINGLE FAN MiNi VRF

More information

excellence in seasonal efficiency BUSINESS SOLUTIONS

excellence in seasonal efficiency BUSINESS SOLUTIONS excellence in seasonal efficiency BUSINESS SOLUTIONS EXCELLENCE in SEASONAL efficiency 8-10 HP The Toshiba SHRM-e, for A whole range of innovations The new Toshiba SHRM-e puts the emphasis on evolution

More information

MiNi-SMMS Design Manual HFC R-410A. Indoor unit. Outdoor unit

MiNi-SMMS Design Manual HFC R-410A. Indoor unit. Outdoor unit Ref.-No. SMME06-111-10-06 MiNi-SMMS Design Manual Indoor unit 4-way ceiling cassette MMU-AP0091H, AP0121H, AP0151H, MMU-AP0181H, AP0241H, AP0271H, MMU-AP0301H, AP0361H, AP0481H Compact 4-way ceiling cassette

More information

Engineering Data Book

Engineering Data Book E10-331 Engineering Data Book 3 compressors & 3 inverters Super Modular Multi System < Digest version > Notice: Toshiba is committed to continuously improving its products to ensure the highest quality

More information

DESIGN MANUAL R410A. Indoor Unit. Outdoor Unit FILE NO. A Cooling Only Model <Inverter Unit> Heat Pump Model <Inverter Unit>

DESIGN MANUAL R410A. Indoor Unit. Outdoor Unit FILE NO. A Cooling Only Model <Inverter Unit> Heat Pump Model <Inverter Unit> FILE NO. A03-008 DESIGN MANUAL R410A Indoor Unit MMU-AP0091H, AP0121H, AP0151H, MMU-AP0181H, AP0241H, AP0271H, MMU-AP0301H, AP0361H, AP0481H MMU-AP0561H

More information

Super Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit

Super Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit Ref.-No. SMMS02-AE-10-05 Indoor unit 4-way ceiling cassette MMU-AP0091H, AP0121H, AP0151H, MMU-AP0181H, AP0241H, AP0271H, MMU-AP0301H, AP0361H, AP0481H MMU-AP0561H 2-way ceiling cassette MMU-AP0071WH,

More information

Digital Inverter 4 series 8 & 10HP

Digital Inverter 4 series 8 & 10HP E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct

More information

Inventor of the Inverter

Inventor of the Inverter Inventor of the Inverter MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL COST SAVING INSTALLATION R410A HIGH EFFICIENCY HIGH RELIABILITY QUIET OPERATION SMALL AND LIGHTWEIGHT Model Type Model Name Capacity

More information

Super. Digital Inverter. Inverter Air Conditioning for Light Commercial Use

Super. Digital Inverter. Inverter Air Conditioning for Light Commercial Use Super Digital Inverter Inverter Air Conditioning for Light Commercial Use Super Digital Inverter Toshiba Super Digital Inverter series air conditioners combine economy and ecology in a compact body. They

More information

DESIGN MANUAL R410A. Outdoor Unit. FS unit FILE NO. A RBM-Y1122FE RBM-Y1802FE RBM-Y2802FE

DESIGN MANUAL R410A. Outdoor Unit. FS unit FILE NO. A RBM-Y1122FE RBM-Y1802FE RBM-Y2802FE FILE NO. A04-017 DESIGN MANUAL R410A Heat Recovery Type Indoor Unit MMU-AP0091H, AP0121H, AP0151H, MMU-AP0181H, AP0241H, AP0271H, MMU-AP0301H, AP0361H, AP0481H MMU-AP0561H

More information

Side blow VRF. Engineering Data Book. Outdoor units E Model name: MCY-MHP0404HT-E MCY-MHP0504HT-E MCY-MHP0604HT-E

Side blow VRF. Engineering Data Book. Outdoor units E Model name: MCY-MHP0404HT-E MCY-MHP0504HT-E MCY-MHP0604HT-E E14-361 Model name: MCY-MHP0404HT-E MCY-MHP0504HT-E MCY-MHP0604HT-E Side blow VRF Engineering Data Book Outdoor units Notice: Toshiba is committed to continuously improving its products to ensure the highest

More information

TOSHIBA Super Heat Recovery Multi Enhanced System Standard Specification

TOSHIBA Super Heat Recovery Multi Enhanced System Standard Specification Introduction The following specification describes the Toshiba 3-Pipe Super Heat Recovery Multi air conditioning system e (SHRMe) to be installed at the site below: The system(s) shall consist of the following

More information

4-Way Cassette type. Contents MMU-AP 2H2UL

4-Way Cassette type. Contents MMU-AP 2H2UL E15-3C1 6 Indoor unit MMU-AP 2H2UL 4-Way Cassette type MMU-AP0072H2UL MMU-AP0092H2UL MMU-AP0122H2UL MMU-AP0152H2UL MMU-AP0182H2UL MMU-AP0212H2UL MMU-AP0242H2UL MMU-AP0302H2UL MMU-AP0362H2UL MMU-AP0422H2UL

More information

Technical HandBook. Version

Technical HandBook. Version Technical HandBook 24 Hour Technical Helpline: 0870 843 0333 Fault & DN Code Apps: Android & iphone Web Page toshiba calc.co.uk/fault codes/ Fault Code Text Service: 07624 803 017 technical.enquiries@toshiba-ac.com

More information

TAKING OMFORT TO A WHOLE NEW DIMENSION

TAKING OMFORT TO A WHOLE NEW DIMENSION c TAKING OMFORT TO A WHOLE DIMENSION High Ambient Application EXCELLENCE IN AIR CONDITIONING SMMS-e Brochure_ The manufacturer reserves the right to change the product specifications, data and images without

More information

Engineering. Super Heat Recovery Multi System

Engineering. Super Heat Recovery Multi System Engineering Super-HRM Data Book Super Heat Recovery Multi System Foreword This engineering data book provides several useful data,charts and drawings to clarify the best performance of Toshiba Super Heat

More information

Air to Air Heat Exchanger

Air to Air Heat Exchanger Air to Air Heat Exchanger VN-M1HE / VN-M2HE VN-M3HE / VN-MHE VN-M6HE / VN-M8HE VN-M1HE VN-M1HE VN-M2HE Air to Air Heat Exchanger MMD VN2HEXE MMD VN82HEXE MMD VN12HEXE with DX-coil Type CONTENTS 1. Specifications

More information

Compact 4-way Cassette ( ) Type

Compact 4-way Cassette ( ) Type E08-0 Engineering Data Compact 4-way Cassette (600 600) Type Indoor Unit RAV-SM40MUT-E RAV-SM4MUT-E Outdoor Unit RAV-SP404AT-E RAV-SP44AT-E Contents. Specifications. Connecting pipe length and lift difference

More information

ELECTRICAL QUANTITY WEIGHT (LB)

ELECTRICAL QUANTITY WEIGHT (LB) VRF SYSTEM INDOOR UNIT ENTERING AIR TEMPERATURES ( F) CAPACITIES (kbtuh) Max SOUND ELECTRICAL WEIGHT TOSHIBA-CARRIER COOLING HEATING Airflow PRESSURE, MARK NO. TYPE ROOM TOTAL SENSIBLE HEATING V / Ø /

More information

TOSHIBA AIR CONDITIONING. TOSHIBA Super Heat Recovery Multi System Standard Specification

TOSHIBA AIR CONDITIONING. TOSHIBA Super Heat Recovery Multi System Standard Specification Introduction The following specification describes the Toshiba 3-Pipe Super Heat Recovery Multi air conditioning system(s) to be installed at the below site: (ADD SITE NAME) The system(s) shall consist

More information

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF 2016 Commercial Air Conditioners VRF 60Hz V4+SV4+RV4+WMini VRF OUTDOOR UNIT LINEUP INDOOR UNIT LINEUP 1.8 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 20.0 25.0 28.0 40.0 45.0 OUTDOOR UNIT

More information

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION FUJITSU VRF PRODUCT CATALOGUE 2016/17 VRF VENTILATION SPLIT MULTI SPLIT VRF VENTILATION SUPPORT Design Simulator Automatically create model selection information Each unit can be automatically set by entering

More information

SERVICE MANUAL MMU-AP0092H, MMU-AP0122H, MMU-AP0152H, MMU-AP0182H, MMU-AP0242H, MMU-AP0272H, MMU-AP0302H, MMU-AP0362H, MMU-AP0482H, MMU-AP0562H,

SERVICE MANUAL MMU-AP0092H, MMU-AP0122H, MMU-AP0152H, MMU-AP0182H, MMU-AP0242H, MMU-AP0272H, MMU-AP0302H, MMU-AP0362H, MMU-AP0482H, MMU-AP0562H, FILE NO. A08-004 SERVICE MANUAL MMU-AP0092H, MMU-AP022H, MMU-AP052H, MMU-AP082H, MMU-AP0242H, MMU-AP0272H, MMU-AP0302H, MMU-AP0362H, MMU-AP0482H, MMU-AP0562H, This Service

More information

LIGHT COMMERCIAL RANGE Inverter heat pumps suitable for both homes and commercial premises

LIGHT COMMERCIAL RANGE Inverter heat pumps suitable for both homes and commercial premises LIGHT COMMERCIAL RANGE Inverter heat pumps suitable for both homes and commercial premises Toshiba Heat Pumps. We care about better air. Toshiba was the first company to incorporate inverter technology

More information

Toshiba s new VRF breaks ground for efficiency, Continuous heating and hands-free commissioning

Toshiba s new VRF breaks ground for efficiency, Continuous heating and hands-free commissioning As a world leader in electronics, Toshiba is committed to delivering the highest standards of quality and innovation. Toshiba set the benchmark in energy efficiency with significant technological advances

More information

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG Spring 2017 Edition BRYANT VRF ADVANTAGES IT TAKES an Efficient Solution...1 What is Variable Refrigerant Flow (VRF)...1 Simultaneous Heating & Cooling...1

More information

Commercial Air Conditioning Equipment

Commercial Air Conditioning Equipment Commercial Air Conditioning Equipment COMMERCIAL EQUIPMENT SALES Contact Us: CARRIER HEADQUARTERS AUSTRALIA 34-40 Garden Boulevard, Dingley Vic 3172 Ph: +61 (03) 9264 9555 Fax: +61 (03) 8551 0380 SYDNEY

More information

Engineering Data Book

Engineering Data Book E13-3O1 Heat recovery Model name: MMY-MAP_4FT9UL (208/230 V, 60 Hz) MMY-MAP_4FT6UL (460 V, 60 Hz) Heat pump Model name: MMY-MAP_4HT9UL (208/230 V, 60 Hz) MMY-MAP_4HT6UL (460 V, 60 Hz) Engineering Data

More information

for Light Commercial Use

for Light Commercial Use Inverter Air Conditioning for Light Commercial Use 4 Toshiba's unique energy-efficient air conditioning innovations and technologies deliver high energy savings. Aluminum heat exchanger * High heat exchanger

More information

Inverter Air Conditioning for Light Commercial Use

Inverter Air Conditioning for Light Commercial Use Inverter Air Conditioning for Light Commercial Use 3 DI Digital Inverter Light Commercial The Toshiba Digital Inverter series air conditioners combine economy and ecology in a compact body They feature

More information

VRV IV S-series heat pump

VRV IV S-series heat pump VRV IV S-series heat pump The most compact VRV Most compact unit on the market 3mm high & kg Control systems Indoor units VRV type indoor units Residential type indoor units (such as Daikin Emura) Air

More information

DC Inverter Smart VRF Products(R410A)

DC Inverter Smart VRF Products(R410A) DC Inverter Smart VRF Products(R410A) General Description What is DC Inverter Smart? Inverter Smart system is YDS system: 1. With DC inverter compressor; 2. Condensing unit and heat pump type; 3. It is

More information

VRV IV i-series heat pump

VRV IV i-series heat pump VRV IV i-series heat pump for indoor installation unique patented concept Air curtain Biddle Air curtain for VRV (CYV) 22 Indoor units VRV type indoor units Control systems Ventilation Heat Reclaim ventilation

More information

Energy-saving operation

Energy-saving operation DC Inverter can attain both comfort a Energy-saving operation All the models of Panasonic FS Inverter Series are equipped with DC inverters for the higher EER operation. The new design attains quiet and

More information

Hitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE

Hitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE Hitachi Air Conditioning Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE Set Free VRF Systems Mini 2-pipe S i d e fl o w2 - p i p e Modular 2 or 3-pipe Std - Efficiency Hi-Efficiency

More information

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design Special Heat Exchanger Design 4 way air return heat exchanger design Reduce the heat exchanger height (6mm), and the upper and lower wind speed uniform and high efficiency. Air Supply Chamber and Equipment

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2017-4-25 New CMV System - Floor ceiling Indoor Unit 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram

More information

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)- Suary PAGE: 1 / 47 1 This Technical Bulletin introduces the new outdoor units of the SET-FREE FSXN1E Series (8 to 54HP) using R410A. 2 The details are indicated in the description. Index 1. Main concepts...

More information

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES turn to the experts SM R 410A DC INVERTER LIGHT COMMERCIAL SERIES DC Inverter Technology More Economical Energy Efficient Once indoor air temperatures reach your desired levels, inverter driven air-conditioners

More information

AIR CONDITIONER (MULTI TYPE) Owner s Manual. Outdoor Unit. Owner s Manual 1 English. Owner s Manual xx Xxxxx. Model name: <Cooling Only Model>

AIR CONDITIONER (MULTI TYPE) Owner s Manual. Outdoor Unit. Owner s Manual 1 English. Owner s Manual xx Xxxxx. Model name: <Cooling Only Model> AIR CONDITIONER (MULTI TYPE) Outdoor Unit Model name: MMY-MAP0804HT8-E MMY-MAP1004HT8-E MMY-MAP1204HT8-E MMY-MAP1404HT8-E MMY-MAP1604HT8-E MMY-MAP0804HT8Z-E MMY-MAP1004HT8Z-E MMY-MAP1204HT8Z-E

More information

Inventor of the Inverter Digital Inverter System

Inventor of the Inverter Digital Inverter System Inventor of the Inverter Digital Inverter System Inventor of the Inverter The Digital inverter from Toshiba combines economy and ecology in a smart body. It offers state-of-the-art technology, exceptional

More information

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL PRODUCT LINEUP VRF For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL 100 AIRSTAGE VRF Systems can be designed to create an air conditioning solution to suit most building requirements. AIRSTAGE VRF Systems

More information

Variable Refrigerant Flow

Variable Refrigerant Flow Variable Refrigerant Flow Two-pipe Heat Recovery and Heat Pump Systems Heat Recovery Single-chassis Design Heat Pump Modular Design Table of Contents Carrier VRF Advantages 2 Revolutionary Design 3 Advanced

More information

MMY-MAP1606HT8P-C MMY-MAP1806HT8P-C MMY-MAP2006HT8P-C MMY-MAP2206HT8P-C

MMY-MAP1606HT8P-C MMY-MAP1806HT8P-C MMY-MAP2006HT8P-C MMY-MAP2206HT8P-C FILE NO. M-5067- SERVICE MANUAL AIR-CDITIER (MULTI TYPE) Outdoor Unit Model name: MMY-MAP0806HT8(J)P MMY-MAP006HT8(J)P MMY-MAP06HT8(J)P MMY-MAP06HT8(J)P

More information

Light commercial range. Passion at work

Light commercial range. Passion at work Light commercial range Passion at work 2 Light Commercial Solutions for professionals, from professionals Toshiba-Carrier Super Digital Inverter systems deliver exceptional operating savings in extremely

More information

INVERTER DUCTED SYSTEMS

INVERTER DUCTED SYSTEMS INVERTER DUCTED SYSTEMS What you ll find inside: DC Twin-Rotary Compressor Inverter Ducted advantages Controllers Product Specifications Energy Efficient Powerful Operation Flexible Application 1 About

More information

AIR CONDITIONER (MULTI TYPE) Owner s Manual. Outdoor Unit. Model name: Heat Pump Model MCY-MHP0406HT-E MCY-MHP0506HT-E. English. For commercial use

AIR CONDITIONER (MULTI TYPE) Owner s Manual. Outdoor Unit. Model name: Heat Pump Model MCY-MHP0406HT-E MCY-MHP0506HT-E. English. For commercial use 1FAN_OM_DHV0000201-00_EN.book Page 1 Wednesday, August 16, 2017 9:55 AM DHV0000201-00 English AIR CONDITIONER (MULTI TYPE) Owner s Manual Outdoor Unit For commercial use Model name: Heat Pump Model MCY-MHP0406HT-E

More information

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER Manual No. '06 PAC, KX-T-110 TECHNICAL MANUAL Collection data PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) FDUMVA201HEN2R 251HEN2R 302HEN2R 402HEN2R 502HEN2R 602HEN2R MULTI-TYPE (V-MULTI)

More information

AIR CONDITIONER (MULTI TYPE) SERVICE MANUAL

AIR CONDITIONER (MULTI TYPE) SERVICE MANUAL FILE No. A10-033 AIR CONDITIONER (MULTI TYPE) SERVICE MANUAL This service manual provides relevant explanations about new indoor unit (4 series). Please refer to the following service manuals for each

More information

Product Line Introduction. Karl Zhang Technical support engineer

Product Line Introduction. Karl Zhang Technical support engineer Product Line Introduction Karl Zhang Technical support engineer Air Conditioning Solutions Heating & Hot Water Solutions Control Solutions Air Conditioning Solutions Residential Application Commercial

More information

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems Technology that works fast Ducted Systems About Toshiba s Ducted systems. Combining high power with high efficiency. Toshiba s Ducted systems allows you to air The Toshiba Air Conditioning DC Hybrid. The

More information

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems Technology that works fast Inverter Ducted Systems About Toshiba s Inverter Ducted systems. Toshiba s Inverter Ducted systems allows you to air condition your home without having to install the indoor

More information

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems Technology that works fast Inverter Ducted Systems About Toshiba s Inverter Ducted systems. Toshiba s Inverter Ducted systems allows you to air condition your home without having to install the indoor

More information

Integrated VarIable refrigerant flow ahu/pau (r410a)

Integrated VarIable refrigerant flow ahu/pau (r410a) Integrated Variable Refrigerant Flow AHU/PAU (R410A) CONTENTS Features of VRF AHU/PAU 2 WELAIRE i-gt Concept 9 VRF Outdoor Unit Performance Data 10 Drawings & Performance Data 12 Dimensions 13 Notes 14

More information

3 rd Generation of VRV. The professional solution for your professional project

3 rd Generation of VRV. The professional solution for your professional project 3 rd Generation of VRV The professional solution for your professional project CONTENT What is VRV? Definition, History, Concept VRVIII Range Outdoor units, indoor units. VRVIII features Piping limits,

More information

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series Commercial Air Conditioners 2017/2018 VRF 50/60Hz V5 X Series Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and

More information

AIR-TO-AIR HEAT EXCHANGERS. Air Treatment Solutions

AIR-TO-AIR HEAT EXCHANGERS. Air Treatment Solutions 217 AIR-TO-AIR HEAT EXCHANGERS Air Treatment Solutions AIR TREATMENT SOLUTIONS 2 I TOSHIBA Ventilation - the key to enhanced quality of life Air pollution has become a serious worldwide problem. In urban

More information

Inverter Ducted XPower 42QSS

Inverter Ducted XPower 42QSS 3D DC Inverter Timer Sleep Mode Turbo Mode Auto Leak Detection 49 Compact and versatile is the ideal choice for new or refurbished buildings Key Features EUROVENT CERTIFIED PERFORMANCE: Eurovent Certification

More information

Ceiling Mounted Cassette Unit

Ceiling Mounted Cassette Unit Brochure AP-MCK-13 Ceiling Mounted Cassette Unit Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date

More information

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value. Midea Ducted and Cassette Split Systems Maximum versatility, maximum value. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

TOSHIBA AIR CONDITIONING

TOSHIBA AIR CONDITIONING Digital Inverter Standard Specification R32 Introduction The following specification describes the Toshiba Digital Inverter Heat Pump air conditioning system(s) to be installed at the below site: (ADD

More information

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC January 2018 Engineering Data RXSQ24-60TAVJU Heat Pump 208/230V / 60 Hz / 1 ph Presales Manual DAIKIN NORTH AMERICA LLC DAIKIN NORTH AMERICA LLC RXSQ_TAVJU VRV LIFE TM Heat Pump Unit Contents 1. Features

More information

Multi Air Conditioning System for Buildings

Multi Air Conditioning System for Buildings Multi Air Conditioning System for Buildings Large Capacity Multi VRF System DC Inverter Control Compressor Long Piping System Design High Efficiency Refrigerant R410A All for Comfort Smart and cutting

More information

Just feel well. 2017/2018 Air conditioning

Just feel well. 2017/2018 Air conditioning 1947-20 17 2017/2018 Air conditioning Unique solutions 40 Unique and advanced design for vertical or horizontal installation VERTICAL INSTALLATION q Vertical installation with compact dimensions, only

More information

INSTALLATION MANUAL. Outdoor Unit. Indoor Unit FILE NO. A Cooling Only Model. Heat Pump Model. Heat Pump Model

INSTALLATION MANUAL. Outdoor Unit. Indoor Unit FILE NO. A Cooling Only Model. Heat Pump Model. Heat Pump Model FILE NO. A03-0 INSTALLATION MANUAL Unit MMU-AP009H, AP0H, AP05H, MMU-AP08H, AP04H, AP07H, MMU-AP030H, AP036H, AP048H MMU-AP056H MMU-AP007WH,

More information

TRIO TV SERIES VERTICAL IMPACT CRUSHERS. Highly Efficient Crushing Solutions.

TRIO TV SERIES VERTICAL IMPACT CRUSHERS. Highly Efficient Crushing Solutions. TRIO TV SERIES VERTICAL IMPACT CRUSHERS Highly Efficient Crushing Solutions www.trioproducts.com TRIO offers World Class Design, Engineering and Manufacturing to provide high value solu ons for your crushing,

More information

Ultimate VRF System R410A, 50Hz

Ultimate VRF System R410A, 50Hz Ultimate VRF System R410A, 50Hz TVR WIZ Systems, a new leap in technology and innovation A proven solution from a trusted advisor Trane is proud to present their new line of variable refrigerant systems,

More information

SERVICE MANUAL AIR-CONDITIONER (MULTI TYPE)

SERVICE MANUAL AIR-CONDITIONER (MULTI TYPE) FILE NO. A10-1508 SERVICE MANUAL AIR-CONDITIONER (MULTI TYPE) OUTDOOR UNIT Model name: MCY-MHP0404HS8(J)-E/0504HS8(J)-E/0604HS8(J)-E MCY-MHP0404HS8(J)-TR/0504HS8(J)-TR/0604HS8(J)-TR MCY-MHP0404HS8(J)/0504HS8(J)/0604HS8(J)

More information

Inverter Ducted Air Conditioners

Inverter Ducted Air Conditioners Inverter Ducted Air Conditioners About Carrier inverter ducted systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making

More information

Inverter console UFV system. Compact design and personalised air flow selection

Inverter console UFV system. Compact design and personalised air flow selection Inverter console UFV system Compact design and personalised air flow selection 2 Efficient and reliable system Thanks to Toshiba DC Hybrid Inverter technology the system operates at maximum capacity in

More information

Bringing a year round comfort solutions to extreme climates

Bringing a year round comfort solutions to extreme climates ooling or Heating ZUBDN series PUHYHP YHM(BS) PUHYHP YSHM(BS) Bringing a year round comfort solutions to extreme climates ITY MULTI ZUBDN series combines the ultimate in application flexibility and powerful

More information

comfort where it counts Variable Speed Ductless Split Systems Single Zone Air Conditioners / Heat Pumps

comfort where it counts Variable Speed Ductless Split Systems Single Zone Air Conditioners / Heat Pumps comfort where it counts Variable Speed Ductless Split Systems Single Zone Air Conditioners / Heat Pumps 2 EMI E-verter Ductless Split Systems are an excellent alternative for cooling and heating indoor

More information

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS mini-cassette 18.000 24.000 AUTO MODEL MDH13HLS MDH13HLS Cooling capacity W 3852 3852 Cooling capacity BTU/h 13135 13135 The best Heating technology capacity W in air conditioning 4205 4205 Heating capacity

More information

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air technical data FDKS-CVMB Concealed ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDKS-CVMB TABLE OF CONTENTS FDKS-CVMB 1 Features.............................................................

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house. Midea Ducted and Cassette Split Systems Year round comfort, all around the house. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS Now Only One Unit Required for Initial Start-up L Multi Zone Inverter Heat Pump High Efficiency Multi 21+ heat pump units can heat and cool up to 5 zones without

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to

More information

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 Product Data INDUSTRY LEADING FEATURES / BENEFITS AN INEXPENSIVE AND

More information

AIR CONDITIONER (MULTI TYPE) Owner s Manual

AIR CONDITIONER (MULTI TYPE) Owner s Manual AIR CONDITIONER (MULTI TYPE) Owner s Manual Outdoor Unit Model name: For commercial use MMY-MAP0806HT8P-ME MMY-MAP006HT8P-ME MMY-MAP06HT8P-ME MMY-MAP406HT8P-ME MMY-MAP606HT8P-ME MMY-MAP806HT8P-ME

More information

DC inverter Outdoor-air Processing unit (GC )

DC inverter Outdoor-air Processing unit (GC ) DC inverter Outdoor-air Processing unit (GC201109- ) ER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTERNDITINER TECHNICAL SALES GUIDE-50Hz CAPACITY RANGE:14~56kW

More information

Samsung Free Joint Multi Air Conditioning System

Samsung Free Joint Multi Air Conditioning System Samsung Free Joint Multi Air Conditioning System Air Conditioning solutions from a brand you can rely on At the heart of family living is the home, a place full of special moments and wonderful memories

More information

Ceiling Mounted Cassette Unit

Ceiling Mounted Cassette Unit CEILING CASSETTE A5CK-E SERIES - R410A COOLING ONLY A5CK20E A5CK25E A5CK28E A5CK40E A5CK40E A5CK40E A5CK40E A5CK50E A5LC20C A5LC25C A5LC28C A5LC35D A5LC35D A5LC40D A5LC40D A5LC50D Btu/hr 18300 22200 27000

More information

Heat Pump Air Conditioning Systems

Heat Pump Air Conditioning Systems Heat Pump Air Conditioning Systems Create your own Utopia. In a climate as diverse as ours air conditioning your premises can make a huge difference to the comfort of your staff, and your customers too.

More information

Residential and Light Commercial Ductless Systems Catalog

Residential and Light Commercial Ductless Systems Catalog Residential and Light Commercial Ductless Systems Catalog May 2018 Table of Contents Midea Global 3 Ductless Benefits 5 Single and Multi-Zone Solutions 9 Single Zone Residential 13 Max Series 15 Advantage

More information

Ductless Systems. Right product for the right application

Ductless Systems. Right product for the right application Ductless Systems Right product for the right application Right Product for the Right Application Single-Zone Multi-Zone Light Commercial RAS System High Wall (Up to 23 SEER) RAV-**KRT System High Wall

More information

Ductless Series Variable Speed Split Systems

Ductless Series Variable Speed Split Systems P r e se n t s Ductless Series Variable Speed Split Systems Ductless Series Variable Speed Split Systems 2 EMI E-verter Ductless Split Systems are an excellent alternative for cooling and heating indoor

More information

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air technical data FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDXS-CVMB TABLE OF CONTENTS FDXS-CVMB 1 Features.............................................................

More information

A GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA

A GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA A GUIDE TO COMFORT HITACHI INVERTER SPLIT SYSTEMS Enjoy the Silence with Quiet Mode With Hitachi, noisy air conditioners are a thing of the past. Our modern Full Flat design has ensured efficient yet ultra-quiet

More information

HEAT PUMPS SiOS SYSTEM TERMINAL UNITS UNICO CONDITIONER FIXED AIR PORTABLE AIR CONDITIONER AIR COOLER DEHUMIDIFIERS HUMIDIFIERS FAN HEATERS GAS STOVES

HEAT PUMPS SiOS SYSTEM TERMINAL UNITS UNICO CONDITIONER FIXED AIR PORTABLE AIR CONDITIONER AIR COOLER DEHUMIDIFIERS HUMIDIFIERS FAN HEATERS GAS STOVES PERSONAL COMFORT 109 THE RANGE The air conditioner without outdoor unit, patented and designed by Olimpia Splendid in 1998. Unico, born with 15 years of experience. A complete range of solutions with no

More information

MRVIII-S. 007 Features & Benefits 017 MRVIII-S Outdoor

MRVIII-S. 007 Features & Benefits 017 MRVIII-S Outdoor 1 7 Features & Benefits 17 Outdoor 5 6 (SIDE DISCHARGE) OUTDOOR STRUCTURE (/1/12HP SIDE DISCHARGE) More Bigger Outdoor Capacity, More Flexible Application High efficiency DC fan motor Vector inverter control

More information

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER FTQ SERIES HEATING AND COOLING SYSTEMS MULTI-POSITIONAL AIR HANDLER Up to

More information