RECUPERA DRY Controlled mechanical ventilation with dehumidification and air treatment GB 01. Air conditioning. Ideas to install
|
|
- Buck Martin
- 6 years ago
- Views:
Transcription
1 REUPER DRY ontrolled mechanical ventilation with dehumidification and air treatment GB 0 ir conditioning Ideas to install
2 Recover... your wellbeing The home is a precious asset where we all spend a major time of your life. So it s important that it be kept as clean as possible. Ventilation, whether mechanical or natural, allows us to control factors such as temperature, humidity and pollutants in the air, preventing the formation of surface and interstitial condensation and the subsequent development of unpleasant mould. Given that nowadays buildings are highly insulated against outside temperatures, it is becoming increasingly difficult to eliminate vapours generated in indoor environments on a daily basis. In fact, the mere presence of a person inside a room releases a significant quantity of moisture humidity. Moreover, simple actions such as washing our hands, drying clothes or cooking, release significant quantities of aqueous vapours. Unless the building is properly ventilated, this aqueous vapour will tend to condense on relatively colder surfaces such as the walls; if the building is properly ven tilated however, this excess moisture will be pushed towards the outside, thereby preventing the formation of condensation. In addition to maintaining air temperature and relative humidity conditions, ventilation allows control over pollutants inside the home; simply think about the quantity of O each person releases when breathing, simple actions such as cooking (which releases fumes and odours into the environment), cleaning the home (which releases airborne organic compounds contained in cleaning products) or smoking a cigarette (which releases nicotine and other polluting elements). Moreover, inside the buildings hide a series of other pollutants often unbeknownst to us, such as pollens or insects (which enter the home during the different seasons throughout the year), radon (a natural gas found in soil, which infiltrates homes) or carbon monoxide (due to poor combustion in heating systems or stoves). So it s not only indoor environments that are polluted, but also outdoor ones. s a consequence however, given that rooms are ventilated during the part of the day when environmental pollution is at its highest, ventilation itself can be dangerous for the air we breathe. Until today, the most common method of exchanging air in indoor environments was to open the doors and windows, but given the hectic rhythms of modern day life, this isn t always easy. Moreover, compared to older buildings, modern construction technology has made building insulation even more efficient; however, while allowing us to use less energy for heating, this also results in significantly less air infiltration, particularly from the doors and windows. Unlike natural ventilation systems, a controlled mechanical system always ensures the right quantity of air is exchanged. The process is continuous and adjustable depending on the activities being performed by the occupants. The exchanged air is continuously controlled through a filtration system that prevents the introduction of pollutants from the outside. This is why Emmeti recovers your wellbeing, allowing you to live in a healthy environment thanks to correct air temperature and relative humidity conditions and significantly less pollutants.
3 Recover... your energy The cost of energy and power savings are a continuous source of worry during everyday life. simple gesture such as opening the doors and windows to exchange the air can increase the cost of heating in buildings by more than a third. In order to ensure correct ventilation in the home, as well as healthy conditions in the environments in which we live, doors and windows should be opened for twenty minutes every two hours; in addition to being a complicated operation in light of our daily routines, this is also extremely wasteful from an economical point of view due to the cold air that is subsequently let inside. On the other hand, a controlled mechanical ventilation system with heat recovery ensures the correct level of air exchange, with almost zero impact on heating costs. Thanks to high-efficiency heat recovery, the warm air present in the rooms cross with the cold air from the outside, without ever mixing, transferring the heat. This simple device reduces external energy dispersion throughout the various periods of the year. In fact, while it prevents heat from escaping the building in the winter months, it also prevents the heat from entering in the summer months, thereby significantly reducing building operating costs. Moreover, thanks to mechanical ventilation systems, it is possible to monitor the correct flow of air from the outside, based on the real needs of the building. This means that unlike in the case of natural ventilation by opening windows, occupants can enjoy a healthy environment, exchanging only the air effectively necessary in order to ensure maximum comfort. By recovering the energy already present in the different environments, the building becomes more efficient, less economically wasteful and requires less energy to work. ll this improve the building energy certification, helping to maintain and even improve the building s value over time. Both models can be combined with external sensors (motion, O and humidity) and are equipped with E high-efficiency brushless motors, which considerably reduce consumption and allow improved regulation of the air flow based on the real needs of each individual system. This is why Emmeti recovers your energy, allowing you to live in an efficient home, with real energy savings. Uses Recupera Dry is an integrated solution of ontrolled Mechanical Ventilation (MV) units with dehumidification and air treatment for residential ambients. Thanks to a radiant floor system and one plant for air distribution into the rooms, the air can be treated in the various seasons satisfying different ambient needs in therm of comfort. REUPER-DRY can be apply for: Summer: - ir renewal with heat recovery; - Dehumidifying air; - ir renewal with heat recovery, with dehumidification and possible cooling. Winter - ir renewal with heat recovery; - ir heating; - ir renewal with heat recovery, with heating integration The air flows treated by the REUPER-DRY can be set via the control panel, the speed of the electric fans is adjusted automatically to ensure the pre-fixed air flow in the distribution channels and solve the relative pressure drops. The air introduced into the environment can be made up from two air flows: renewal with heat recovery and air recirculation. The renewal and recirculation flows can be combined, if desired, depending on the flow rates and the type of treatment to be carried out.
4 How does Recupera Dry operate controlled mechanical ventilation system ensures constant air renewal in the respective rooms in the home, extracting it from the most polluted environments, such as bathrooms, kitchens and laundries; introducing fresh air, withdrawn from the common areas of the home such as the living room and bedrooms. With Recupera Dry, connected to the ventilation system and to the heating plant circuit, it is possible to treat the air and ensure maximum environment comfort and minimum air consumption. Intake of fresh air from the outside Stale return air from the inside The system consists of the following components: Expulsion stale air outside Room air recirculation Room air deliver pipe (renewal + recirculation) Recupera Dry: fans actioned by low consumption brushless motors, force inlet air flow (from internal rooms) and external air througout a high efficiency-crossed flows heat recovery unit. In this way the internal heat can be recobered. The air is taken from the rooms and from outdoors by the fans, and passes them through the recovery unit at highly efficient crossed flows, recovering the energy contained inside the hous. Remote ontrol for E motors: controls the ventilation flow rate and gives information on any filters cleaning or replacements. External air grills: allow inlet and expulsion of air, avoiding entrance to the building of foreign bodies and water. Piping: it is a piping network within the building that distributes and regulates air inside the building, avoiding transmission of noise inside the house. Terminals: they distribute the air flow inside rooms avoiding creation of annoying drafts and transmission of noise between different rooms.
5 omponents 9 L K J B D E ir/air heat recovery system; ompressor; Finned integration coil (water); Operating scheme Finned coil (evaporator); Finned coil (condenser ); Plate heat exchanger (condenser ); entrifugal fan (room air delivery pipe); entrifugal fan (air expulsion); 9 Electric control board (controller and terminal board); J Motorised damper (room air recirculation); K Motorised damper (external air intake); L Motorised damper (bathroom air intake); Electronic expansion solenoid valve. M M Room air deliver pipe (renewal + recirculation) PB EV EV B Stale return air from the inside. Intake of fresh air from the outside. D Expulsion stale air outside. E Room air recirculation.
6 Technical features The machine is made up from a galvanised sheet structure with particular heat and noise isolation which encloses: a direct expansion cooling circuit for dehumidification of the air, an additional finned heat exchanger to connect to the heating system for summer/winter integration, a high efficiency air/air heat recovery system, motorised dampers for the adjustment of the respective air flows, accessible G filters positioned in the respective unit air inlet pipes, two brushless variable flow electric fans, a condensate collection tray, an electric control board and a remote control panel to be installed on a guide in a wall-hung electric control board. Technical data Models u.m. UT-RID00- Total dehumidification capacity (Outdoor temperature, 0% RH) /day,9 Useful dehumidification capacity (Indoor recirculation) (*) l/day,9 Energy recovering (winter) (Indoor temp. 0 / 0% RH - outdoor temp. - / 0% RH) 9% Outlet air flow fan (min-max) m³/h 0-00 MX Loss of charge Pa 0 Power absorbed fan (min-max) W - 0 Expulsion air flow fan (min-max) m³/h 0-0 MX Loss of charge Pa 00 Power absorbed fan (min-max) W - 0 Useful cooling capacity (Indoor recirculation) (*) W 00 Water flow (*) l/h 00 Water pressure drop (*) kpa Inlet temp. water cooling (min-max) - 9 Power supply V~/ph/Hz 0//0 Max power absorbed W 90 Refrigerant (Ra) kg 0, Sound pressure level at m db() 9 Weight kg Supplementary heat exchange Total cooling capacity ( ) W 90 Sensible cooling capacity ( ) W 0 Heating capacity ( ) W 00 Water pressure drop kpa, (*) Inlet air condition % RH, inlet water temp., nominal airflow rate ( ) Inlet air condition % RH, in/out water temp. /, nominal airflow rate ( ) Inlet air condition 0, in/out water temperature /0, nominal airflow rate Dimensions [mm] ,
7 onnections 9 cooled water inlet cooled water outlet summer condensate drain winter condensate drain air delivery pipe into room room air recirculation expulsion of stale air renewal air inlet stale air intake ontrol panel The machine has a remote control panel to be mounted on a DIN guide in a wall-mounted electric control board. The control panel has n. terminal boards, to which the following connections can be made: the connection to the machine, via the wires that allow the panel electric power supply ( V) and the serial communication with the circuit board; the digital consents for the various functions to activate; the two digital outputs with relay, which allow to activate a circulation pump and an alarm in the case of malfunctioning. Functions that can be activated via the digital inputs: current season; renewal (yes, no, automatic); dehumidification; cooling (heating in winter); attenuation of the air flow. Settings available from the keyboard: activation of the functions (as an alternative to digital consents); current time; current season (as an alternative to digital consent); air flow rate in delivery and renewal mode; normal delivery and integration temperature for each season; automatic renewal time bands (maximum ); flow rate attenuation time bands (maximum ). It is also possible to read the values of the machine temperature sensors; useful in the inspection or verification phase of correct operation. Output di uscita relay MODBUS connection to the card of del Recupera Dry Dry LRM EMMETI Recupera-Dry Ingressi Digital Inputs digitali
8 SUMMER operating mode Only Renewal (neutral air) This mode is set by activating the RENEWL function (from the keyboard, or from the external contact DI0 via timer or O sensor). The recirculation damper K and L and the fans are turned on. The fresh air is cooled by the water coil and connected to the radiant system; consequently, to power this battery, an approval is sent to the N0 pump/valve output of the area/chiller/climate controller, and the air temperature is maintained equal to the neutral air temperature value, using a modulating valve type 0-0 Vdc (not provided) electrically connected to the output of dedicated Recover Dry. The recirculation air flow rate can be set between 0 and 0 m /h. 0 0 m /h D K L 0 0 m /h B ir supply in the indoor environment (renewal) from 0 to 0 m /h. B Stale air return from inside. Renewal air intake from outside. D Renewal air intake from outside. ctivation via external contacts of control panel ctivation via keyboard of control panel NO NO +V B GND LRM LRM D D 0: Summer Renewal YES ooling NO Dehumidification NO ttenuation NO EMMETI Recupera-Dry / Select: RENEWL Timer O sensor Note: the keyboard commands have priority over the external contact commands.
9 Dehumidification only (recirculation with Dehumidification, neutral air) This mode is set by activating the DEHUMIDIFITION function (from the keyboard, or from the external contact DI0 via humidistat or dehumidification approval from the climate controller e.g. PO or from auxiliary contact hiller). The recirculation damper J, is opened, the compressor and the supply fan are turned on. The recirculation air is pre-cooled by the water coil connected to the manifold of the radiant system (consequently, to power this battery, an approval is sent to the N0 pump/valve output of the area/chiller/climate controller, and the 0-0 Vdc output is powered with a voltage equal to 0 Vdc, for the complete opening of a modulating valve (if present), not supplied, electrically connected to the output dedicated to Recupera Dry); the evaporator D performs the dehumidification. The refrigerant circuit is equipped with two condensers connected in parallel: the air-cooled condenser E water coled, and the plate condenser F which dissipates the excess condensation heat in the chilled water of the radiant system. The two electronic expansion valves present on the refrigerator circuit allow the condensation heat to be distributed in the desired proportion between the two exchangers, in order to obtain neutral air. The recirculation air flow rate can be set between 0 and 00 m /h m /h E 0 00 m /h J ir supply in the indoor environment (recirculation) from 0 to 00 m /h. E mbient air recirculation. ctivation via external contacts of control panel ctivation via keyboard of control panel NO NO +V B GND LRM LRM D D 0: Summer Renewal NO ooling NO Dehumidification YES ttenuation NO EMMETI Recupera-Dry / Select: DRY Humidistat PO regulator Note: the keyboard commands have priority over the external contact commands. 9
10 Renewal + Dehumidification (Renewal + recirculation with Dehumidification, neutral air) This mode is set by activating the RENEWL (from the keyboard, or from the external contact DI0 via timer or O sensor) and DEHUMIDIFI- TION functions (from the keyboard, or from the external contact DI0 via humidistat or approval from the climate controller e.g PO or from the auxiliary contact hiller). The dampers K and L and the recirculation damper J, are opened, the compressor and the fans and are turned on. The recirculation air is pre-cooled by the water coil connected to the manifold of the radiant system (consequently, to power this battery, an approval is sent to the N0 pump/valve output of the area/chiller/climate controller, and the 0-0 Vdc output is powered with a voltage equal to 0 Vdc, for the complete opening of a modulating valve (if present), not supplied, electrically connected to the output dedicated to Recupera Dry); the evaporator D performs the dehumidification. The refrigerant circuit is equipped with two condensers connected in parallel: the air-cooled condenser E and the plate condenser F which dissipates the excess condensation heat in the chilled water of the radiant system. The two electronic expansion present on the refrigerator circuit allow for the condensation heat to be distributed in the desired proportion between the two exchangers, so as to obtain neutral air. The air flow in the room can be set between 0 and 00 m/h; the renewal air flow rate can be set between 0 and 0 m /h. The recirculation flow rate is determined by the difference between the air flow and the renewal air flow rate. The damper J is open in modulation mode to ensure the ratio between flow rates. E 0 00 m /h D J K L 0 0 m /h B ir supply in the indoor environment (renewal - recirculation) from 0 to 00 m/h. B Stale air return from inside. Renewal air intake from outside. D Renewal air intake from outside. E mbient air recirculation. ctivation via external contacts of control panel ttivazione tramite tastiera pannello di controllo D LRM / 0: Summer Renewal YES ooling NO Dehumidification YES ttenuation NO EMMETI Recupera-Dry Timer O sensor / Select: RENEWL and DRY Note: the keyboard commands have priority over the external Humidistat PO Regulator contact commands. 0
11 Renewal + ooling (Renewal + recirculation with Dehumidification and ooling) This mode is set by activating the RENEWL (from the keyboard, or from the external contact DI0 via timer or O sensor) and OOLING functions (from the keyboard, or from the external contact DI0 via ambient humidistat). The dampers K and L and the recirculation damper J, are opened, the compressor and the fans and are turned on. The recirculation air is pre-cooled by the water coil connected to the manifold of the radiant system (consequently, to power this battery, an approval is sent to the N0 pump/valve output of the area/chiller/climate controller, and the 0-0 Vdc output is powered with a voltage equal to 0 Vdc, for the complete opening of a modulating valve (if present), not supplied, electrically connected to the output dedicated to Recupera Dry); the evaporator D performs the dehumidification. The refrigerant circuit is equipped with two condensers connected in parallel: the air-cooled condenser E and the plate condenser F which dissipates the excess condensation heat in the chilled water of the radiant system. The two electronic expansion present on the refrigerator circuit allow for the condensation heat to be distributed in the desired proportion between the two exchangers, so as to obtain cooled air. The air flow in the room can be set between 0 and 00 m /h; the renewal air flow rate can be set between 0 and 0 m /h. The recirculation flow rate is determined by the difference between the air flow and the renewal air flow rate. The damper J is open in modulation mode to ensure the ratio between flow rates. E 0 00 m /h D J K L 0 0 m /h B ir supply in the indoor environment (renewal - recirculation) from 0 to 0 m /h. B Stale air return from inside. Renewal air intake from outside. D Expulsion of stale air outside. E mbient air recirculation. ctivation via external contacts of control panel ctivation via keyboard of control panel D D 0: Summer Renewal YES ooling YES Dehumidification NO ttenuation NO LRM EMMETI Recupera-Dry / Select: RENEWL and OOLING Timer O sensor Room thermostat Note: the keyboard commands have priority over the external contact commands.
12 WINTER operating mode Renewal only (neutral air) This mode is set by activating the RENEWL function (from the keyboard, or from the external contact DI0 via timer or O sensor). The dampers K and L are opened and the fans and are turned on. The renewal air is heated by the water coil connected to the radiant system; consequently, to power this battery, an approval is sent to the N0 pump/valve output of the area/chiller/climate controller, and the air temperature is kept equal to the value of the neutral air temperature set, by means of a modulating valve of the type 0-0 Vdc (not supplied) electrically connected to the output dedicated to Recupera Dry. The renewal air flow rate can be set between 0 and 0 m /h. 0 0 m /h D K L 0 0 m /h B ir supply in the indoor environment (renewal) from 0 to 0 m /h. B Stale air return from inside. Renewal air intake from outside. D Expulsion of stale air outside. ctivation via external contacts of control panel ctivation via keyboard of control panel NO NO +V B GND LRM LRM D D 0: Summer Renewal YES ooling NO Dehumidification NO ttenuation NO EMMETI Recupera-Dry / Select: RENEWL Timer O sensor Note: the keyboard commands have priority over the external contact commands.
13 Heating only (recirculation with Heating) This mode is set by activating the HETING function (from the keyboard, or from the external contact DI0 via ambient thermostat). The recirculation damper J, is opened, the compressor and the supply fan G are turned on. The renewal air is heated by the water coil connected to the radiant system; consequently, to power this battery, an approval is sent to the N0 pump/valve output of the area/chiller/climate controller, and the air temperature is kept equal to the value of the neutral air temperature set, by means of a modulating valve of the type 0-0 Vdc (not supplied) electrically connected to the output dedicated to Recupera Dry. The recirculation air flow rate can be set between 0 and 00 m /h m /h E 0 00 m /h J ir supply in the indoor environment (recirculation) from 0 to 00 m /h. E mbient air recirculation ctivation via external contacts of control panel ctivation via keyboard of control panel NO NO +V B GND LRM LRM D D 0: Summer Renewal NO ooling YES Dehumidification NO ttenuation NO EMMETI Recupera-Dry Select: WRMING Room thermostat Note: the keyboard commands have priority over the external contact commands.
14 Renewal + Heating only (Renewal + recirculation with Heating) This mode is set by activating the RENEWL (from the keyboard, or from the external contact DI0 via timer or O sensor) and HETING functions (from the keyboard, or from the external contact DI0 via ambient humidistat). The dampers K and L and the recirculation damper J, are opened, the fans and are turned on. The air (renewal + recirculation) is heated by the water coil connected to the radiant system; consequently, to power this battery, an approval is sent to the N0 pump/valve output of the area/chiller/climate controller, and the air temperature is kept equal to the value of the neutral air temperature set, by means of a modulating valve of the type 0-0 Vdc (not supplied) electrically connected to the output dedicated to Recupera Dry. The air flow in the room can be set between 0 and 00 m /h; the renewal air flow rate can be set between 0 and 0 m /h. The recirculation flow rate is determined by the difference between the air flow and the renewal air flow rate. The damper J is open in modulation mode to ensure the ratio between flow rates. 0 0 m /h E 0 00 m /h D J K L 0 0 m /h B ir supply in the indoor environment (renewal - recirculation) from 0 to 00 m /h. B Stale air return from inside. Renewal air intake from outside. D Expulsion of stale air outside. E mbient air recirculation. ctivation via external contacts of control panel ctivation via keyboard of control panel D D 0: Summer Renewal YES ooling YES Dehumidification NO ttenuation NO LRM / EMMETI Recupera-Dry Timer O sensor Room thermostat Select: RENEWL and HET Note: the keyboard commands have priority over the external contact commands.
15 Flow performance Fan to supply air inside Fan to expel the air outside Static pressure [Pa] Static pressure [Pa] ir flow [m /h] ir flow [m /h] 00 Installation example POE expansion module Remote terminal with display (optional) TS Electric box with thermostat safety External probe Niña S boiler PO climatic regulator Open manifold* limatic Floor ontrol Unit HE Mirai SMI heat pump T probe room temperature T/H probe room temperature/humidity Recupera Dry Emmeti lima Floor floor circuits *The volume of the open collector / accumulation should be determined in function of the capacity of the heat pump.
16 Respect the environment! For a correct disposal, the different materials must be divided and collected according to the regulations in force. Emmeti copyright ll rights are reserved. This publication nor any of its contents can be reproduced or publicized without Emmeti s written authorization. The data contained in this publication are subject to change without prior notice for further product improvement. Rev Ufficio Pubblicità & Immagine - SR EMMETI spa - Via Brigata Osoppo, - 0 Vigonovo frazione di Fontanafredda (PN) - Italia Tel Fax info@emmeti.com
Controlled mechanical ventilation GB 03
RECUPER SLIM 2018 Controlled mechanical ventilation GB 03 ir conditioning Systems to install Recover... your wellbeing The home is a precious asset where we all spend a major time of your life. So it s
More informationLow Temperature Radiator GB 01. Heating & Plumbing. Ideas to install
Low Temperature Radiator GB 01 Heating & Plumbing Ideas to install Low temperature radiator The E2 low temperature radiator is a one-of-a-kind product, since it makes emission of heat at low temperature
More informationFHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions
Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area
More informationGHE Dehumidifiers for radiant cooling systems with heat recovery
Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area
More informationGHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES
Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area
More informationGHE. Dehumidifiers for radiant cooling systems with heat recovery. Display
GHE Dehumidifiers for radiant cooling systems with heat recovery Display The dehumidifiers with heat recovery of high efficiency series GHE were designed to provide dehumidification and fresh air in a
More informationFHE. Dehumidifiers for radiant cooling systems with heat recovery. Display. Versions
FHE Dehumidifiers for radiant cooling systems with heat recovery Display The dehumidifiers with heat recovery of high efficiency series FHE were designed to provide dehumidification and fresh air in a
More informationECO HOT WATER Air-water heat pump for domestic hot water with integrated solar panels and remote control via App GB 02. Ecoenergy.
ECO HOT WTER ir-water heat pump for domestic hot water with integrated solar panels and remote control via pp GB 02 Ecoenergy Ideas to install The Eco Hot Water heat pump The EMMETI heating pumps have
More informationDehumidification and ventilation for residential, industrial radiant systems and swimming pools
Dehumidification and ventilation for residential, industrial radiant systems and swimming pools HiDew is proud to present a complete range of dehumidifiers for radiant cooling systems and high performance
More informationDC INVERTER Air-Water heat pump for Heating and Cooling Residential environments with the PLANT MANAGEMENT SYSTEM INTEGRATED in the heat pump GB 04
INVRTR ir-water heat pump for Heating and ooling Residential environments with the PLNT MNMNT SYSTM INTRT in the heat pump 04 coenergy Ideas to install The MIRI-SMI heat pump The state of the art heating
More informationDehumidification and ventilation for residential, industrial radiant systems and swimming pools
Dehumidification and ventilation for residential, industrial radiant systems and swimming pools HiDew is proud to present a complete range of dehumidifiers for radiant cooling systems, industrial processes,
More informationHeat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools
Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL
More informationAir treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings
0932EN October 2017 CHARACTERISTIC DATA Air flow rate [m 3 /h] 200 Pressure available (factory configuration) [Pa] 15 Moisture removed (26 C - 65% R.H. - inlet water 15 C) [l/24h] 24,7 Max. absorbed electric
More informationSPLIT System. SPLIT System Simple and flexible direct expansion solutions for the commercial sector and industry
System System Simple and flexible direct expansion solutions for the commercial sector and industry System is the autonomous solution for climate control in small and medium shops. The cooling or thermal
More informationFH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions
Dehumidifiers for radiant cooling systems FH GH 138 The dehumidifiers FH and GH series are high performance units, equipped with robust galvanised steel frame, properly designed to operate in combination
More informationFCX FAN COIL SILENT & EFFICIENT. Floor, ceiling & ducted installation Applicable with VMF management system, Plasmacluster filter option
FCX FAN COIL SILENT & EFFICIENT Floor, ceiling & ducted installation Applicable with VMF management system, Plasmacluster filter option THE AERMEC FAN COILS Fan coils and Aermec: a combination where the
More informationHeat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications
Heat Pump Technology Air Source, Water Source and Ground Source Optimised heat pumps for residential and commercial applications ICS Cool Energy Limited has nearly 25 years experience in supplying and
More informationSMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB
T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING
More informationHumidity Control Systems for Civil Buildings in Hot Summer and Cold. Winter Zone in China
Humidity Control Systems for Civil Buildings in Hot Summer and Cold Winter Zone in China Xiaoping Yu Doctoral Candidate Chongqing University of Science & Technology Chongqing, China, 400042 xiaoyup@163.com
More informationCAIRfricostar CAU Controller with Remote Control SUPPLEMENT TO OPERATION MANUAL
CAIRfricostar CAU Controller with Remote Control SUPPLEMENT TO OPERATION MANUAL Table of Contents CAIRfricostar CAU Controller Table of Contents 1 Functional description of the unit... 3 1.1 Operation
More informationLZT High efficiency air to water heat pumps with E.V.I. compressors
High efficiency air to water heat pumps with E.V.I. compressors -20 +43 +65 E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems
More informationMODUCEL KW DOWNFLOW COOLING DRU DRU DATA ROOM UNITS
MOUEL 80-10 KW OWNFLOW OOLING RU RU T ROOM UNITS T ROOM UNITS The Moducel range of high efficiency ata Room Units, are designed for high density load areas where a large cooling duty is required from a
More informationWZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors
High Efficiency ir to Water Split System Heat Pumps With E.V.I. ompressors -20 +43 +65 HP E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor
More informationOMNIA RADIANT FAN COIL WITH RADIANT HEATING PANEL THE FAN COIL FEATURING 3 HEATING MODES
RADIANT FAN COIL WITH RADIANT HEATING PANEL THE FAN COIL FEATURING 3 HEATING MODES Floor & ceiling installation On/off & inverter versions, applicable with VMF management system 2 Aermec OMNIA RADIANT
More informationAir magic NTD500 Neutral Temperature Dehumidifier Air magic HRV500 Heat Recovery Ventilation. designed for radiant cooling systems.
Air magic NTD500 Neutral Temperature Dehumidifier Air magic HRV500 Heat Recovery Ventilation designed for radiant cooling systems User s Manual CONTENTS 2 Chapter 1 GENERAL INFORMATION page 4 Chapter 2
More informationCZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or
More informationFH - GH Dehumidifiers for radiant cooling systems
Dehumidifiers for radiant cooling systems FH GH The dehumidifiers FH and GH series are high performance units, equipped with robust galvanised steel frame, properly designed to operate in combination with
More informationCRIMSON & CRIMSON MAX
High efficiency water/water and geothermal heat pumps 5 114 General High efficiency water/water and geothermal heat pumps. Ideal for heating, cooling and production of domestic hotwater with total or partial
More informationTOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS
TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS Energy saving thanks to a total recovery p Cooling Heating/DHW h Galletti multi-purpose heat pumps are total recovery units used for a simultaneous hot and
More informationF series close control air conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings.
F series close control conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings. 38 The F series units are the ideal solution to cool in systems
More informationFAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney
FAST AND ROBUST BUILDING SIMULATION SOFTWARE Chilled Beam Performance: 1 Shelly Street, Sydney 3D Model Creation 1 Shelley Street, Sydney 3D Model Creation 1 Shelley Street, Sydney Daylight Analysis 1
More informationPRODUCT OVERVIEW. Dehumidifiers
PRODUCT OVERVIEW Dehumidifiers IdROS was formed in 1993 as a distribution company operating in the humidification and dehumidification sector of the air conditioning market. The expansion was rapid and,
More informationLZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors -15 +63 E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems
More informationGemini EC. Engineered with Excellence, Specified with Confidence All-in-One Renewable Energy Climate Control
Gemini EC 1000-12000 All-in-One Renewable Energy Climate Control - Integral Aerothermal fresh air source heat pump boiler - Integral dual function dehumidifying and expelled room air heat pump - Direct-Contact
More informationG E N E R A L C ATA L O G Dehumidif ers
GENERAL CATALOG Dehumidifers INDEX Company Profile Dehumidifiers FH - GH Dehumidifiers for radiant cooling systems 96 GHE Dehumidifiers for radiant cooling systems with heat recovery 102 FHE Dehumidifiers
More informationIndoor Air Quality Product Brochure.
Indoor Air Quality Product Brochure Ventilation: A vital system for a healthy home All homes require adequate ventilation for the safety of their occupants and to remove excess humidity, airborne pollutants
More informationOMNIA RADIANT FAN COIL WITH RADIANT HEATING PANEL THE FAN COIL FEATURING 3 HEATING MODES
OMNIA RADIANT FAN COIL WITH RADIANT HEATING PANEL THE FAN COIL FEATURING 3 HEATING MODES Floor & ceiling installation On/off & inverter versions, applicable with VMF management system OMNIA RADIANT AND
More informationi-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:
ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within
More informationLZT LZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. A + A + VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors + + -0 +43 +65 E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems
More informationVentilation & Heat Recovery. The whole house system from OMNIE
Ventilation & Heat Recovery The whole house system from OMNIE 2 Contents ABOUT OMNIE 4 The Whole house system 6 Why OMNIE Ventilation & Heat Recovery? 7 How does it work? PRODUCT 9 Comfo Air Q MVHR Unit
More informationHIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%
Dry HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES Calculation of savings (for illustrative purposes) Operating scheme Note: power rates refer to 10,000 m 3 /h of air and
More informationTemperature Relative Humidity
Prepared For: John Smith 1234 Any Street Portland, OR 97219 (503) 416-0000 Conducted By: AirAdvice 503-416-7859 Test Period: 4/18/10 4/24/10 Monitor ID: #11922 Report ID: #164139 This report offers recommendations
More informationOPERATION GUIDE MODEL CERV-001-PARTA, CERV-001-PARTB CONDITIONING ENERGY RECOVERY VENTILATOR (CERV)
OPERATION GUIDE MODEL CERV-001-PARTA, CERV-001-PARTB CONDITIONING ENERGY RECOVERY VENTILATOR (CERV) BUILD EQUINOX SUPPORT@BUILDEQUINOX.COM (773)-492-1893 REV 0.50-06/16/2016 Contents Overview... 4 CERV
More informationkw. Flexair. General description. Main components. CLIMATIC controller. Air cooled rooftop packaged unit
Flexair ir cooled rooftop packaged unit 85 0 kw Main applications Large and light commercial buildings inemas, theatres Industrial buildings and logistic centers Why this choice? Energy efficient solution
More informationN M AirControl AHU. Control manual
N 10.63 M 03-2016 AirControl AHU Control manual EN CONTENTS PAGE 1 - MONITORING AND CONTROL 2 1.1 The program 2 1.2 The HMI terminal 2 1.3 The controller 4 1.4 Description of the air handling units 4
More informationFan Coil Range HYDRONIC TERMINALS
Fan Coil Range HYDRONIC TERMINALS This document can be subjected to variations. Descriptions, performance data, images and diagrams are indicative only. For further information contact Climaveneta Comunications/Marketing
More informationYour complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.
RANGE HOODS ATTIC VENTILATORS AIR EXCHANGERS DELUXE RANGE HOODS For more than 25 years, Venmar Ventilation has been one of North America s leading manufacturers of innovative Indoor Air Quality products
More informationCDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.
DEHUMIDIFICATION 9 CDS 80 FUNCTION The CDS 80 works in accordance with the condensation principle. A fan draws the humid air into the dehumidifier and through an evaporator coil. When passing through the
More informationIndoor Air Quality Product Brochure.
Indoor Air Quality Product Brochure Ventilation: A vital system for a healthy home All homes require adequate ventilation for the safety of their occupants and to remove excess humidity, airborne pollutants
More informationNEW. Wall Controls. Air Conditioning Ceiling Air Conditioning Elegant. Cert. n 0545
NEW Wall Controls Cert. n 0545 Air Conditioning Ceiling Air Conditioning Elegant CONTENTS Page Introduction 3 Main components 4 Dimension, Weight, Water content 5 Main technical figures 6 Working conditions
More informationwww.ecso-klimatechnik.de ECSO GMBH Wetterssteimstr. 53 D- 90471,.. Nurnberg, Deutschland e-mail: info@ecso-klimatechnik.de Tel/Fax: +49 (0) 911/818 9917 TABLE OF SYMBOLS OPERATING MODE OPTIONS VENTILATION
More informationImproving your home comfort by enhancing the air
i n d o o r a i r q u a l i t y Improving your home comfort by enhancing the air The perfect answer to air quality problems? Healthy Climate Solutions. With fuel and electricity costs on the rise, today
More informationSHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C
SHERPA Th e multifunctional air-water split heat pump. PATENTED TECHNOLOGY The combination of an inverter air-water heat pump together with a water-water heat pump allows heating/ and high temperature
More informationCHAPTER 4. HVAC DELIVERY SYSTEMS
CHAPTER 4. HVAC DELIVERY SYSTEMS 4.1 Introduction 4.2 Centralized System versus Individual System 4.3 Heat Transfer Fluids 4.4 CAV versus VAV Systems 4.5 Common Systems for Heating and Cooling 4.6 Economizer
More informationEpsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points
Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique
More informationDEMAND-CONTROLLED HOME VENTILATION
DEMAND-CONTROLLED HOME VENTILATION DEMAND-CONTROLLED HOME VENTILATION No more worrying about the indoor climate The indoor climate must be taken seriously A good indoor climate is all about health and
More informationLAF 50 / 100 / 150. Condensing dehumidifiers for professional use. Accessories. Design. Approvals LAF
LAF Dehumidifiers LAF D e h u m i d i f i e r s LAF 50 / 100 / 150 Condensing dehumidifiers for professional use VEAB condensing dehumidifiers are designed for professional use in application in which
More informationSPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module
SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:
More informationCZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with
More informationState of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney
Frenger Radiant chilled beam performance at 3D Model Creation Daylight Analysis Comparison of the performance of various HVAC systems at 1 Shelly St, Sydney VAV fancoil Active chilled beam Passive chilled
More informationNRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER
NRP MULTIPURPOSE HEAT PUMPS AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER Multipurpose air cooled units with axial fans. For external installation. High efficiency version. NRP MULTIPURPOSE
More informationHealthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs
i n d o o r a i r q u a l i t y s o l u t i o n s Healthy Climate Indoor Air Quality s s that fit your unique needs Healthy Climate Indoor Air Quality s Custom, whole-home product solutions that reduce
More informationAppendix 13. Categories of Cooling and Heating systems
EcoShopping - Energy efficient & Cost competitive retrofitting solutions for Shopping buildings Co-funded by the European Commission within the 7 th Framework Programme. Grant Agreement no: 609180. 2013-09-01
More informationMECHANICAL VENTILATION
MECHANICAL VENTILATION Natural and Mechanical Systems Four (4) possible combinations of natural and mechanical ventilations tions are as follows; Natural inlet and outlet; utilizing open able windows,
More informationb.) Technical Information:
Section VI- Strategies a.) Summary: It is important for new construction designers to consider the heating, ventilation, and air conditioning needs within a building. There are many different systems,
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are
More informationAPC APPLICATION NOTE #119
#119 InRow RP-CW and InRow RP-DX Environmental Control By Henry Jespersen Abstract The primary function of the InRow RP product is to cool air from the hot aisle and deliver it to the cold aisle at the
More informationReference Guide for Microprocessor Controller
Document 483232 Microprocessor Controller for Energy Recovery Reference Guide for Microprocessor Controller Please read and save these instructions for future reference. Read carefully before attempting
More informationGEYSER kw. General information. Unique selling points
6 78 kw General information Dedicated heat pumps new series with Scroll compressors, with and without vapor injection. /HT version in 15 sizes Cooling capacity (35;W7): 6 73 KW Heating capacity (7;W45):
More informationHealthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs
i n d o o r a i r q u a l i t y s o l u t i o n s Healthy Climate Indoor Air Quality Solutions Solutions that fit your unique needs Healthy Climate Indoor Air Quality Solutions Custom, whole-home product
More informationWE ARE CONTINUOUSLY ADDING TO AND IMPROVING OUR INDOOR AIR QUALITY PRODUCTS TO PROTECT YOUR FAMILY S HEALTH.
WE ARE CONTINUOUSLY ADDING TO AND IMPROVING OUR INDOOR AIR QUALITY PRODUCTS TO PROTECT YOUR FAMILY S HEALTH. ARE YOU WINNING THE WAR ON INDOOR AIR QUALITY? Are you putting up a fight? Due to the high percentage
More informationAIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw
COMFORT HEAT PUMPS AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw climaveneta.com COMFORT HEAT PUMPS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air to water heat pump for outdoor installation,
More informationJH Series Installation
JH Series Installation Space Heating / Fresh Air Make-Up From the Manufacturers of Hi-Velocity Systems TM Includes: JH-15 JH-30 Module-JH-Series-Installation-Manual-010118 Installation JH fan coils by
More informationH3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog
H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...
More informationCOMPACT AIR HANDLING UNIT
COMFORT AIR HANDLING UNITS COMPACT AIR HANDLING UNIT climaveneta.com COMFORT AIR HANDLING UNITS AIR TREATMENT ENHANCING QUALITY OF LIFE. Compact air handling unit for indoor and outdoor installation. Air
More information> > > Heat pump systems. Water Chillers. Dehumidifiers
> > > Heat pump systems Water Chillers Dehumidifiers Company Profile What is a heat pump? A heat pump is a device that moves heat from one location (called the source ) to another location (called the
More informationBRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.
More information
LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES
LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are
More informationWATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED
EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units
More informationTechnical Information
How to design easily a smoke management system? Mechanical smoke extraction for enclosed car park Car park: specificity of the smoke extraction system Car parks are nowadays integrated directly inside
More informationComplete Ventilation, Heat Recovery and Dehumidification Packaged System by. Maintaining Your Climate for Indoor Pools and Waterparks
Ventilation Heat Recovery PoolPak International Maintaining Your Climate for Indoor Pools and Waterparks Complete Ventilation, Heat Recovery and Dehumidification Packaged System by PoolPak International
More informationAdconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h
Comfort air conditioning 76 Comfort air conditioning unit with counterflow plate heat exchanger Automatically selects the most economical operating mode! 76 13 76 01 13 with 01 - Adiabatic simplified Pro
More informationAWR MTD2 XE. Versions
Versions ETING COOLING OT WTER ETING COOLING OT WTER ir/water reversible heat pump for water heating up to 58 C and operating limits down to -15 C external air temperature and domestic hot water production.
More informationAlfamini-Alfamax series
Alfamini-Alfamax series High efficiency air handling unit for wellness areas Air flow rates from 4.000 to 25.000 m 3 /h 1012-6180971-rev.02 Trattamento dell aria SELECTION MANUAL ISO 9001:2000 - Cert.n
More informationFlexy II Product catalogue
2008/09 Flexy II Product catalogue Providing indoor climate comfort Flexy 85 234 kw Rooftop unit Introduction to the range opeland SROLL compressors for maximum efficiency, reliability and low noise Thermostatic
More informationCORRIGENDUM No.l to the Tender Dossier. Reconstruction of Judicial Academy Building in Belgrade Location - Republic of Serbia
A* Ref. Ares(2018)3663039-10/07/2018 CORRIGENDUM No.l to the Tender Dossier Reconstruction of Judicial Academy Building in Belgrade Location - Republic of Serbia Publication reference: EuropeAid/139201/DD/WKS/RS
More informationPut the V back in HVAC
Put the V back in HVAC V is for Ventilation A system or means of providing fresh air. Webster New Collegiate Dictionary Benjamin Franklin so unwholesome as air in a closed room that has been often breathed
More informationCMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL
CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years
More information... RTU. Packaged Air to Air Heat Pump...
... RU Packaged ir to ir Heat Pump... RU... Packaged ir to ir Heat Pump... Reznor's RU range is composed of air to air heat pumps in packaged rooftop configurations, with various heat recovery options
More informationLCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS
Total heat recovery multi-purpose units LCP Outdoor monobloc air-water unit LCP - kw Heating, cooling, domestic hot water one single system to meet all kinds of needs. Total heat recovery multi-purpose
More informationLZT High efficiency air to water heat pumps with E.V.I. compressors
High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating
More informationPool dehumidification. Airpool+
Pool dehumidification Airpool+ Airpool + The new high performance Airpool+ dehumidifier is used for the dehumidification of indoor pools. Thanks to its design, in which the cooling circuit s components
More informationMULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw
Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01
More informationNext P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB
Next P 6 112 kw COOLING 5 93 kw HEATING Heat pump air conditioners with upflow air delivery technicalcatalogue T_NXTP_0411_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 4 MODEL IDENTIFICATION...
More informationyork airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units
york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units YORK YPRE RTR/RTP SERIES Air to air packaged rooftop units Cooling
More informationSABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM
Air Conditioning Fan Coil Units ICIM ISO 900 - Cert. n 0545/2 Unit heaters Radiant panels Fan coils Air handling units Flues SABIANA ENVIRONMENTAL COMFORT Sabiana is the fan coil that continues the Sabiana
More informationDATATECH. Precision air conditioners for technological environments 6 220
Precision air conditioners for technological environments 6 220 General Precision air-conditioners that guarantee safe working conditions for data centres, computer rooms and other technological applications
More informationCMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N
E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,
More informationDERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E
DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E INTRODUCTION DERV/ERV Introduction Dehumidification & Energy Recovery Ventilator DERV units
More information