CIRCUIT BREAKER - GAS

Size: px
Start display at page:

Download "CIRCUIT BREAKER - GAS"

Transcription

1 CIRCUIT BREAKER - GAS Capabilities: In a large substation, circuit breakers are used to interrupt any short-circuits or overload currents that may occur on the network. A 345 kv, high voltage, three position/phase gas circuit breaker. Description:. Circuit Breaker Gas A 345 KV Three Position Serial Numbers: N/A, N/A, 214, 215, 213, 207, 216, 212, 204, 205, N/A, N/A, 201, 0283A , 0283A In Service: 5/31/1983 thru 8/31/1988 Quantity: 15 units Weight: 51,000 lbs Original Cost: 13 were $281, and 2 were $349, Condition: They appear to be in fair condition. Should be inspected for functionality. Location: X-533A Switch Yard 1

2 TRANSFORMER POWER McGraw-Edison Capabilities: Each transformer is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power 330/13.8 KV 100,000 Serial Numbers: , In Service: 1 in 2/28/ in 1/31/1975. Quantity: 2 units Size: Untanking Height 22 5 Weight: Serial # # To be lifted untanking: lbs Tank and Fittings: lbs Type 442 LTC Mechanism: lbs Oil Main & Selector Comp: Oil lbs Oil 700 Contactor Compartment: 5200 Oil lbs Total: 470, ,100 lbs Original Cost: $758, and $658, Condition: All but one transformer exceeds life cycle. Location: X-533A Switch Yard. 2

3 TRANSFORMER POWER Large Westinghouse Capabilities: Each transformer is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power 330/13.8 KV Serial Numbers: , , , In Service: 2/28/1955. There are tags to indicate an upgrade in Quantity: 4 units. Weight: Core and coils 275,000 lbs Case 128,000 lbs Oil 195,000 lbs Total 598,000 lbs Original Cost: $807, Condition: All transformers do not exceed life cycle. Location: X-533A Switch Yard. 3

4 TRANSFORMER POWER - Westinghouse Capabilities: Each transformer is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power 330/14.4 KV 125 MVA Serial Numbers: , , , , , , In Service: 6/30/1979 Quantity: 7 units. Weight: Core and coils 202,000 lbs Case 50,000 lbs Oil 75,200 lbs Total 327,200 lbs Shipping 232,970 lbs Original Cost: Varied from $701, to $730, Condition: All transformers do not exceed life cycle. Location: X-533A Switch Yard. 4

5 TRANSFORMER POWER - GE Capabilities: Each transformer is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power 330/13.8 KV 100,000 Serial Numbers: C155609, C In Service: 2/28/1958 Quantity: 2 units Weight: When untanking 146,500 lbs Tank & Fitting 108,500 lbs Main tank No. 10-C ,700 lbs Top selector No. 10-C 790 5,900 lbs Contactor No. 10-C 520 3,900 lbs Total 397,500 lbs Original Cost: $757, and $706, Condition: According to identified markings all transformers exceed life cycle. Location: X-533A Switch Yard. 5

6 TRANSFORMER POWER Allis-Chalmer Capabilities: Each transformer is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power 330/13.8 KV 100,000 Serial Numbers: , In Service: The one located in the switchyard 12/31/1954. Quantity: 2 units. Size: Height 460 inches Weight: Core and coil 296,700 lbs Oil ,000 lbs Tank & Fitting 105,300 lbs Total 559,000 lbs Original Cost: $963, for one in Switch Yard. Condition: According to identified markings all transformers exceed life cycle. Location: One transformer is in X-533A Switch Yard and one transformer is on a concrete pad behind the X-533A Switch Yard. 6

7 TRANSFORMER POWER BBC Capabilities: It is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power HV 13.8 KV/LV 2.4 KV Serial Number: SB In Service: Unknown Life Cycle: Unknown Quantity: 1 unit. Weight: Core and coils 2,934 lbs Oil ,582 lbs Tank & Fitting 1,087 lbs Total 5,603 lbs Original Cost: Unknown Condition: Unknown Location: It is setting disconnected on a concrete pad behind X-533A Switch Yard. 7

8 TRANSFORMER POWER PowerZone Capabilities: It is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power KVA 1500/ Volts Serial Number: In Service: Unknown. Life Cycle: Unknown. Quantity: 1 unit. Size: Untanking height of 150 inches. Weight: Core and coil 4,055 lbs Oil ,342 lbs Tank & Fitting 3,743 lbs Total 12,140 lbs Original Cost: Unknown. Condition: Unknown. Location: It is setting disconnected on a concrete pad behind X-533A Switch Yard. 8

9 TRANSFORMER POWER Fayetteville Capabilities: It is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power KVA 6000 OA / 7500 FA Delta Volts Serial Number: In Service: Unknown. Life Cycle: Unknown. Quantity: 1 unit. Size: Untanking height of 150 inches. Weight: Core and coil 14,000 lbs Tank & Fitting 9,595 lbs Oil 960 gallons 7,105 lbs Total 30,700 lbs Original Cost: Unknown. Condition: Unknown. Location: It is setting disconnected on a concrete pad behind X-533A Switch Yard. 9

10 TRANSFORMER POWER GE Capabilities: It is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power KVA 6000 OA / 7500 FA Delta Volts Serial Number: B In Service: Unknown. Life Cycle: Unknown. Quantity: 1 unit. Weight: Untanking 191,000 lbs Tank & Fitting 108,500 lbs Oil 1700 gallons Main 127,000 lbs Oil 790 Gallons 5,900 lbs Oil 520 gallons Contactor 3,900 lbs Total 436,500 lbs Original Cost: Unknown. Condition: Unknown. Location: It is setting disconnected on a concrete pad behind X-533A Switch Yard. 10

11 TRANSFORMER POWER Square D Company Capabilities: It is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power Serial Number: In Service: Unknown. Life Cycle: Unknown. Quantity: 1 unit.. Weight: Core and coil 2,540 lbs Tank & Fitting 2,765 lbs Oil 280 gallons 2,100 lbs Untanking 2,540 lbs Total 7,405 lbs Original Cost: Unknown. Condition: Unknown. Location: It is setting disconnected on a concrete pad behind X-533A Switch Yard. 11

12 TRANSFORMER GROUNDING GE Zig Zag Capabilities: Grounding transformers are used in utility distribution networks and in some power electronic converters in order to provide a neutral point in a three-wire system. Description: Transformer Grounding Zig Zag GE OA-JT. Serial Numbers: H A, H B In Service: 6/30/1979 Quantity: 2 units. Weight: Untanking 3,800 lbs Tank & Fitting 1,850 lbs 10C Oil 425 Gallon 3,150 lbs Total 8,800 lbs Original Cost: $24, Condition: They appears to be in fair condition with over 9 years of life cycle remaining. Location: X-533A Switch Yard. 12

13 TRANSFORMER GROUNDING GE Capabilities: A grounding transformer is used to provide a ground path to either an ungrounded "Y" or a delta connected system. Description: Transformer Grounding Zig Zag GE OA-J. Serial Numbers: C155653, C155654, C155655, C155651, C155656, C155649, C155648, C155643, C155647, C155645, C155646, C155642, C155644, C In Service: 2/28/1955 Quantity: 15 units. Weight: Untanking 5,875 lbs Tank & Fitting 1,850 lbs 10C Oil 400 Gallon 3,000 lbs Total 10,725 lbs Original Cost: $24, Condition: They appears to be in good condition. Location: One transformer is on the concrete pad behind the X-533A Switch Yard and all others are in the X-533A Switch Yard. 13

14 BUS DUCT SYSTEM Capabilities: This configuration offers superior strength as well as reduced weight when compared to steel or copper rectangular designs. Provides equalization of reactance between phases no phase transposition is required on long runs. Description: A 13.8 KV bus duct system from transformer to building. Serial Numbers: N/A In Service: 5/31/1955 Quantity: 1 system. Original Cost: $2,455, Condition: Good working condition. However, it is past its life cycle. Location: X-533A Switch Yard. 14

15 A HEATING AND VENTILATING SYSTEM Capabilities: Uses a fan to force air through air ducts to create ventilation. Steam coils are routed near the fan to produce heat when it is cold. Steam can be turn on or off according to the need. Oil is used as a filtering system. Description: Heating and ventilation system. In Service: 2/28/1955 Life Cycle: 35 yrs. Quantity: 2 systems and unknown number of feet for ventilation duct. Weight: Original Cost: $162, Condition: They appear to be in fair condition and is currently in working condition. However, they are past their life cycle. Location: One in each Switch House of X-533B. 15

16 LIGHTING SYSTEM Capabilities: To provide adequate lighting throughout the switchyard for work to be performed during limited visibility periods. Description: An interior electric lighting system. In Service: 3/31/1957 Life Cycle: 30 yrs. Quantity: 1 system. Weight: N/A Original Cost: $285, Condition: It appears to be in fair condition and is currently in working condition. However, it is past its life cycle. Location: Both X-533B Switch House buildings and control building. 16

17 FIRE ALARM SYSTEM Capabilities: System contains manual and automatic alarm initiators. The system contains an audible warning and uses water for fire suppression and/or containment. Description: Fire Alarm System (Switchhouse). Two separate systems tied together for alarm. In Service: 2/28/1955 Life Cycle: 35 yrs. Quantity: 1 system. Original Cost: $147, Condition: Appears to be in fair condition and is still being relied on. However, it is past its life cycle. Location: X-533 Complex. 17

18 CONDENSER SYNCHRONOUS - Large Capabilities: An apparatus for controlling voltage flicker in power distribution in a substation, comprising a synchronous condenser, a field adjuster for the synchronous condenser and a compensation circuit, apparatus being adapted to compensate the distribution voltage flicker due to a large load variation in substation and being able to adjust a predetermined distribution voltage within an allowable range. Description: Condenser Synchronous Serial Numbers: , , , In Service: 6/30/1955 Quantity: 4 units. Weight: Estimated 240,000 lbs Original Cost: $855, Condition: Appears to be in fair condition. Location: X-533B. There are two at the top of each Switch House. 18

19 SWITCHGEAR UNIT SUBSTATION 480 VOLTS Capabilities: A switchgear is used both to de-energize equipment to allow work to be done and to clear faults downstream. Description: Switchgear Unit Substation 480 Volt 3/phase Serial Number: In Service: 6/30/1955 Quantity: 2 systems. Original Cost: $17, Condition: Appears to be in good condition. Location: One in each Switch House at X-533B. 19

20 CONDENSER SYNCHRONOUS Capabilities: An apparatus for controlling voltage flicker in power distribution in a substation, comprising a synchronous condenser, a field adjuster for the synchronous condenser and a compensation circuit, apparatus being adapted to compensate the distribution voltage flicker due to a large load variation in substation and being able to adjust a predetermined distribution voltage within an allowable range. Description: Condenser Synchronous to Serial Numbers: 6-S-10088, 6-S-10088, 3-S-10088, 2-S-10088, 5-S-10088, 4-S In Service: 6/30/1955 Quantity: 6 units.. Weight: Estimated 140,000 lbs Original Cost: $287,743 to $295,657 Condition: Appears to be in fair condition. Location: X-533B. There are three at the top of the East/West Switch House. 20

21 SYNCHROSCOPE Capabilities: In AC electrical power systems, a synchroscope is a device that indicates the degree to which two systems (generators or power networks) are synchronized with each other. Synchroscopes measure and display the frequency difference and phase angle between two power systems. Description: Synchroscope (including meters fuses) Serial Numbers: N/A In Service: 6/30/1955 Life Cycle: 25 yrs. Quantity: 3 units. Original Cost: $1, Condition: 2 appear to be in fair condition and one is in poor condition. Location: X-533B Control Room. 21

22 INVERTER W/ 5 HP MOTOR Capabilities: This inverter is capable of running any load within its wattage range. Description: Inverter with 5HP Motor MODEL 5A51-25 Serial Number: In Service: 6/30/1955 Life Cycle: 15 yrs. Quantity: 1 unit. Original Cost: $2, Condition: It appears to be in fair condition. Location: X-533B Carrier Room, West Switch House. 22

23 TRANSFORMER DRY TYPE Capabilities: Dry type simply means it is cooled by normal air ventilation. The dry type transformer does not require a liquid such as oil or silicone or any other liquid to cool the electrical core and coils. Description: Transformer - A 2400/480 Dry Type Transformer Serial Numbers: KY In Service: 4/30/1986 Quantity: 2 system. Original Cost: $12, Condition: Appears to be in good working order with a life cycle that expires in Location: One in each X-533B Switch House. 23

24 GENERATOR - DC Capabilities: In a direct current generator, the purpose is to change the alternating current (AC), which flows into its armature, into direct current. Description: Generator DC Motor Emergency 250 VDC Serial Numbers: 74415, In Service: 6/30/1955 Life Cycle: 20 yrs. Quantity: 1 unit. Original Cost: $ Condition: It appears to be in fair condition and is past original life cycle. Location: Downstairs of X-533B Control Building 24

25 DIRECT WRITING OSCILLOGRAPH Capabilities: A recorder in which the permanent record of varying electrical quantities or signals is made on paper, directly by a pen attached to the moving coil of a galvanometer or indirectly by a pen moved by some form of motor under control of the galvanometer. Also known as mechanical oscillograph. Description: Oscillograph Direct Writing 12-Channel In Service: 5/31/1970 Life Cycle: 25 yrs. Quantity: 1 unit. Original Cost: $66, Condition: It appears to be in good condition. Location: X-533B Control Room. 25

26 TRANSFORMER 2500 KVA Capabilities: Each transformer is large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power 2500 KVA 13.8 KV/2 Serial Numbers: 31126TRANS-1, 31126TRANS-2 In Service: 6/30/1955 Quantity: 2 units. Original Cost: $14, Condition: They appear to be in good condition even though past life cycle Location: X-533B East/West Switch House. 26

27 TRANSFORMER 2300/480 Volt Capabilities: Each transformer is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer 2300/480 VOLT 300 KVA In Service: 6/30/1955 Quantity: 2 units Original Cost: $7, Condition: They appear to be in good condition even though past life cycle Location: X-533B East/West Switch House. 27

28 TRANSFORMER 150 KVA Capabilities: Each Transformer is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer 150 KVA Lighting Stockwell, Serial Numbers: 15606, 15607, , In Service: 6/30/1955 Quantity: 5 units. Original Cost: $2, Condition: They appears to be in good condition even though past life cycle Location: X-533B East/West Switch House. 28

29 OSCILLOGRAPH RECORDING FAULT Capabilities: An oscillograph measures variations of electric current by having it go through a magnetic coil. Variations in current induce momentum in the coil, which can be directly measured. Description: Oscillograph A Recording Fault System Serial Number: In Service: 10/31/1986 Life Cycle: 25 yrs. Quantity: 1 units. Size: In a cabinet Original Cost: $88, Condition: Appears to be in good working condition Location: X-533B Control Building 29

30 AIR COMPRESSOR UNIT Capabilities: A compressor takes in air at atmospheric pressure and delivers it at a higher pressure. This pressure is used to operate the three phase switchgears in a substation. Contains pump and air tank. Description: Air Compressor Unit With Compressor Serial Numbers: 10120, 10121, 10126, 10124, 10123, 10122, 10125, 10127, 10137, 10138, 10140, 10139, 10142, 10141, 10131, 10135, 10135, 10136, 10132, 10134, 10133, 10130, 10128, 10129, In Service: 6/30/1955 Quantity: 24 units. Original Cost: $9, Condition: They appear to be in fair working condition. Location: East/West X-533B Switch Houses. 30

31 MAIN CONTROL BOARDS Capabilities: Monitors and controls the power of the switchyard. Description: Main Control Boards - A System of Control In Service: 6/30/1955 Quantity: 1 system. Original Cost: $1,395, Condition: Appears to be in good condition. Location: X-533B Control Room. 31

32 SWITCHGEAR VOLTS Capabilities: Each high voltage switchgear is any switchgear used to connect or disconnect a part of a high-voltage power system. These switchgear are essential elements for the protection and safe operation, without interruption, of a high voltage power system. This type of equipment is important because it is directly linked to the quality of the electricity supply. Description: Switchgear 13,800 VOLT W/11 Air Receiver In Service: 6/30/1955 Quantity: 13 units. Original Cost: Varies from $418, to $503, Condition: They appear to be in fair condition. Location: X-533A. On top of East/West Switch House. 32

33 OIL TANK 15,000 GALLON Capabilities: They purpose is to store mineral oil in order to be used by transformers. Description: Tank Oil Storage gallon capacity In Service: 2/28/1955 Quantity: 2 units Original Cost: $6, Condition: They appear to be in good shape. Location: X-533A (West End) 33

34 OIL TANK 34,000 GALLON Capabilities: They purpose is to store mineral oil in order to be used by transformers. Description: Tank Oil Storage gallon capacity In Service: 2/28/1955 Quantity: 2 units. Original Cost: $10, Condition: They appear to be in good condition. Location: X-533A (West End) 34

35 OIL FILTERING SYSTEM Capabilities: Contained mineral oil to heat and pump oil through transformers in order to filter out impurities. Description: Oil Filtering System with minor tank In Service: 8/31/1974 Life Cycle: Unknown Quantity: 1 system Original Cost: $65, Condition: It appears to be in good working condition Location: X-533A (West End) 35

36 AIR CONDITIONER - WINDOW Capabilities: They re-circulate and cool air to regulate temperature in Control Room. Description: Air Conditioner 220 Volt Friedrich In Service: Unknown Life Cycle: Unknown Quantity: 2 units. Original Cost: Unknown Condition: They appear to be in good working condition and are working. Location: X-533A Control Building 36

37 LUBE OIL PUMPS Capabilities: Pump oil and create oil pressure into the synchronous condenser. It moves middle of synchronous condenser into place until the rotation speed will hold it by itself. Description: Lift and lube oil pumps In Service: Unknown Life Cycle: Unknown Quantity: 8 systems Original Cost: Unknown Condition: They appear to be in fair working condition. Location: X-533B East/West Switch House. 37

38 Heating and Vent Fan Capabilities: The substation ventilation is designed to optimize air circulation over and around the transformers and through the panel compartment so that the substation operates at lower temperatures. Description: Heating and Vent Fan In Service: 3/31/1957 Life Cycle: 30 yrs.. Quantity: 1 system Original Cost: $162, Condition: It appears to be in good working condition Location: X-533B West Switch House 38

39 Hot Water Heater Capabilities: A heating system that uses steam generated from a boiler. The steam heating system conveys steam through pipes to heat exchangers, such as radiators, convectors, radiant panels, or fan-driven heaters, and returns the resulting condensed water to the boiler. Such systems normally operate at pressure not exceeding 15 lb/in.2 gage or 103 kilopascals gage, and in many designs the condensed steam returns to the boiler by gravity because of the static head of water in the return piping. With utilization of available operating and safety control devices, these systems can be designed to operate automatically with minimal maintenance and attention. Description: Steam Fan In Service: Unknown Life Cycle: Unknown Quantity: 16 yrs. Original Cost: Unknown Condition: Condition varies from poor to good. Location: X-533B East/West Switch House 39

40 ELECTRIC HEATER Capabilities: A device for heating rooms that converts electric current to heat by means of resistors that emit radiant energy. Resistors may be composed of metal-alloy wire, nonmetallic carbon compounds, or printed circuits. Heating elements may have exposed resistor coils mounted on insulators, metallic resistors embedded in refractory insulation and encased in protective metal, or a printed circuit encased in glass. Fins may be used to increase the area that dissipates the heat. Description: 480 Volt Heater In Service: Unknown Life Cycle: Unknown Quantity: 16 yrs. Original Cost: Unknown Condition: They appear to be in good working condition Location: X-533B East/West Switch House. 40

Installation Instructions

Installation Instructions 50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions

More information

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT -1SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP S W/OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier

More information

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS -3SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING S PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier Corporation

More information

IEEE Transformer Committee PC Distribution Transformer Monitoring - User

IEEE Transformer Committee PC Distribution Transformer Monitoring - User IEEE Transformer Committee PC57.167 Distribution Transformer Monitoring - User Mark Scarborough Electrical Engineering Consultant DuPont January 9, 2019 Transformer Types in DuPont Control power Dry-type

More information

Contents. Preface. Chapter 2 Faults, types and effects The development of simple distribution systems Faults-types and their effects 7

Contents. Preface. Chapter 2 Faults, types and effects The development of simple distribution systems Faults-types and their effects 7 Practical Power System Protection for Engineers and Technicians Contents Preface ix Chapter 1 Need for protection 1 1.1 Need for protective apparatus 1 1.2 Basic requirements of protection 2 1.3 Basic

More information

TRANS ATLANTIC TRADING ENTERPRISE INC.

TRANS ATLANTIC TRADING ENTERPRISE INC. TA GLOBAL SOLUTIONS INDUSTRIAL COMMERCIAL RESIDENTIAL AUTOMATION +1 (416) 317-3325 +1 (647) 294-2594 www.transatinc.com info@transatinc.com ELECTRICAL BUSWAY DISTRIBUTION EQUIPMENT TRANSFORMERS CIRCUIT

More information

CHP-turbine room. CHP can capture almost EXTRACTED STEAM 20 PSI HIGH-PRESSURE STEAM 1250 PSI HEAT EXCHANGER HOT WATER SUPPLY F

CHP-turbine room. CHP can capture almost EXTRACTED STEAM 20 PSI HIGH-PRESSURE STEAM 1250 PSI HEAT EXCHANGER HOT WATER SUPPLY F 5 6 HIGH-PRESSURE STEAM is routed from the wood-chp boiler to the turbine. TURBINE BLADES spin at nearly 00 revolutions per second. Steam acting on the turbine blades creates mechanical energy in the TURBINE.

More information

www. ElectricalPartManuals. com INSTRUCTIONS DRY TYPE TRANSFORMERS OPERATION AND MAINTENANCE OF

www. ElectricalPartManuals. com INSTRUCTIONS DRY TYPE TRANSFORMERS OPERATION AND MAINTENANCE OF I.L. 46-300-4 INSTRUCTIONS FIG. L Section of Three-Phase ASL Pcwer Center with Class B Insulation. OPERATION Tap Connections. In type ASL dry type trans formers changes in voltages are made by the changing

More information

Typical Applications. Braking Resistor Core Drying Dehumidification Forced Air Comfort Heating

Typical Applications. Braking Resistor Core Drying Dehumidification Forced Air Comfort Heating Process air duct heaters are used for tempering forced air in many industrial processes. Heater wattage is dependent on air outlet temperature (up to 1200 F [650 C]) and air velocity. Smaller duct heaters

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

More information

MOUNT PLEASANT MIDDLE SCHOOL HVAC. M-01 Heating Plant: M-02 Heating & Ventilating Systems: Livingston School District Mount Pleasant Middle School

MOUNT PLEASANT MIDDLE SCHOOL HVAC. M-01 Heating Plant: M-02 Heating & Ventilating Systems: Livingston School District Mount Pleasant Middle School MOUNT PLEASANT MIDDLE SCHOOL HVAC M-01 Heating Plant: The existing boilers have recently been upgraded. (3) steam boilers (8660 mbh each) manufactured by Weil- McLain have been installed. Newer hot water

More information

Cook - Wissahickon Elementary School

Cook - Wissahickon Elementary School Cook - Wissahickon Elementary School 201 E. Salaignac St., Philadelphia, PA 19128 HVAC Replacement Project Scope Determination Report May 10, 2018 Prepared by: G.P. Lamina, Jr., P.E., MBA School District

More information

THRU-THE-WALL AIR CONDITIONERS

THRU-THE-WALL AIR CONDITIONERS THRU-THE-WALL AIR CONDITIONERS 26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. WALLMASTER THRU-THE-WALL AIR CONDITIONERS 27 SLEEVE Ideal for new construction, and as a high efficiency

More information

SECTION STEAM CONDENSATE PUMPS

SECTION STEAM CONDENSATE PUMPS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 22 23 STEAM CONDENSATE PUMPS SPEC WRITER NOTES: 1. Delete between // ---- // if not applicable to project. Also delete any other item or paragraph not applicable

More information

Installation Instructions

Installation Instructions Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A Manufactured Home Installation Instructions NOTE: The Dual Point Kit can only be installed on

More information

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes. Introduction to Hydronics A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes. Hydronic heating systems use hot water or steam to deliver the

More information

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA PART 1 - GENERAL 1.1 Background SECTION 26 00 10- ELECTRICAL DESIGN CRITERIA A. Brown University maintains it own campus electrical distribution system which serves the majority of the buildings and facilities

More information

WHISPA III 5000 WM & 9000 WM. heatingthroughinnovation. Installation, Operating, Maintenance and After Sales Manual. Part Number: Issue 1

WHISPA III 5000 WM & 9000 WM. heatingthroughinnovation. Installation, Operating, Maintenance and After Sales Manual. Part Number: Issue 1 Installation, Operating, Maintenance and After Sales Manual. WHISPA III 5000 WM & 9000 WM heatingthroughinnovation. Product Serial Number: Installation Date: Part Number: 1371054 Issue 1 Tested to UL &

More information

Electric Coils. Blower Coils. Product Information

Electric Coils. Blower Coils. Product Information Product Information General Information Electric heat coils are an available accessory for use with Price blower coil units. The electric heating coils have been specific ally designed to suit Price blower

More information

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit

More information

Installation Instructions

Installation Instructions Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A, Z Chassis Installation Instructions NOTE: Read the entire instruction manual before starting

More information

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC January 2018 Engineering Data RXSQ24-60TAVJU Heat Pump 208/230V / 60 Hz / 1 ph Presales Manual DAIKIN NORTH AMERICA LLC DAIKIN NORTH AMERICA LLC RXSQ_TAVJU VRV LIFE TM Heat Pump Unit Contents 1. Features

More information

Inventory List for Abilene Location

Inventory List for Abilene Location Inventory List for Abilene Location ABL-601 ABL-602 1. Turbine, Steam Generator Steam Turbine Mfr: Allis-Chalmers, Rated KW: 15,000, Initial Pressure: 600 PSIG, Capacity KW: 18,750, Initial Temperature:

More information

C. Samples for Initial Selection: For units with factory-applied color finishes.

C. Samples for Initial Selection: For units with factory-applied color finishes. SECTION 238126- SPLIT-SYSTEM AIR-CONDITIONERS PART 1- GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Property risk solutions

Property risk solutions Property risk solutions Inside this issue Welcome to this edition of the Property risk solutions newsletter. This quarterly publication focuses on fixed fire protection and human element safety solutions

More information

ANNEX A-1 GEOTHERMAL UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES BOILER BALANCE OF PLANT STEAM TURBINE GENERATOR MISCELLANEOUS - GEOTHERMAL EXTERNAL

ANNEX A-1 GEOTHERMAL UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES BOILER BALANCE OF PLANT STEAM TURBINE GENERATOR MISCELLANEOUS - GEOTHERMAL EXTERNAL ANNEX A-1 GEOTHERMAL UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES Boiler Piping System 0500-0620 Condensing System 3110-3199 Circulating Water Systems 3210-3285 Waste Water (zero discharge) 3290-3299 Condensate

More information

State College Area School District High School North Building EXISTING CONDITIONS ASSESSMENT

State College Area School District High School North Building EXISTING CONDITIONS ASSESSMENT State College Area School District High School North Building Prepared by CenterPoint Engineering 08 February 2013 FACILITY ASSESSMENT SUMMARY PHYSICAL PLANT General HVAC This report is a snapshot of the

More information

Installation Instructions

Installation Instructions Electric Heaters 5 --- 20 kw Installation Instructions SMALL PACKAGED PRODUCTS 2to5Tons Accessory Electric Heaters (Single---Point Connection) NOTE: Read the entire instruction manual before starting the

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE Digital Energy Power Quality INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Enhanced Thermal Protection (ETP) Series Integrally Mounted Medium and High Exposure Surge Protective Devices

More information

L A signature series TA T N E RE O, A L L A T S IN

L A signature series TA T N E RE O, A L L A T S IN signature series COMMERCIAL STEAM GENERATORS INSTALLATION, OPERATION AND MAINTENANCE MANUAL INSTALLATION MANUAL COMMERCIAL STEAM GENERATOR SIGNATURE SERIES (SS) INTRODUCTION Steam Sauna manufactures steam

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water

More information

NEC Requirement Guidelines 2002 Code Options for the Installation of Listed Less-Flammable Liquid-Filled Transformers

NEC Requirement Guidelines 2002 Code Options for the Installation of Listed Less-Flammable Liquid-Filled Transformers NEC Requirement Guidelines 2002 Code Options for the Installation of Listed Less-Flammable Liquid-Filled Transformers BULLETIN 92046 APPLICATION INFORMATION NOVEMBER 2002 SUPERSEDES August 2002 CONTENTS

More information

State College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT

State College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT State College Area School District High School South Building Prepared by CenterPoint Engineering 08 February 2013 FACILITY ASSESSMENT SUMMARY PHYSICAL PLANT General HVAC This report is a snapshot of the

More information

Appendix B9 Geothermal Unit Cause Codes

Appendix B9 Geothermal Unit Cause Codes Appendix B9 Geothermal Unit Cause Codes GEOTHERMAL UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES (Unit Codes 800 899) Cause Code BOILER Ranges Page No. Boiler Piping System 0500-0620 B-GE-2 BALANCE OF PLANT

More information

SECTION DOMESTIC WATER HEATERS

SECTION DOMESTIC WATER HEATERS SECTION 223500 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

SERVICING S-15 CHECKING CAPACITOR

SERVICING S-15 CHECKING CAPACITOR S-15 CHECKING CAPACITOR The direct drive motors are of the permanent split capacitor design. A run capacitor is wired across the auxiliary and a portion of the main windings. The capacitors primary function

More information

Glossary. Carbon Dioxide (CO 2

Glossary. Carbon Dioxide (CO 2 Glossary AFUE (Annualized Fuel Utilization Efficiency): A measure of the efficiency of the heating unit (burner and boiler/ furnace) including standby losses during the off-cycles, given on an annual basis.

More information

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED FUEL OIL DAY TANKS SST Series - Engineering Submittal SST Series - Advanced Line Day Tanks Construction: UL 142 aboveground steel tank all seam welded, square, atmospheric tank of heavy gauge steel with

More information

GARCIA GALUSKA DESOUSA Consulting Engineers

GARCIA GALUSKA DESOUSA Consulting Engineers L#56566/Page 1/May 23, 2017 HVAC Heating Plant The original Town Hall building and Addition building are primarily heated by a gas fired hot water plant that is located in the basement. The boiler plant

More information

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS 48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,

More information

ASME Packaged Electric Water Heater

ASME Packaged Electric Water Heater MODEL SH & H ASME Packaged Electric Water Heater 15-1600 KW - All Voltages & Phases, 80-5000 Gallon Capacity Features Reliable Packaged System Only high grade materials used in construction to ensure long

More information

TM Series. Induced Draft, Counter Flow Optional Accessories

TM Series. Induced Draft, Counter Flow Optional Accessories ANTIFREEZE PACKAGE / RESISTANCE HEATING OPTION The antifreeze package is supplied to provide protection against freezing of standing water in the cooling tower sump due to shutdown during winter operation.

More information

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models: INSTALLATION, OPERATION AND MAINTENANCE MANUAL BHW MEDIUM STATIC PRESSURE DUCTABLE TYPE Models: 174 205 358 410 515 720 724 Cooling capacities from 3,1 to 25 KW Heating capacities from 4,5 to 55,5 KW Thank

More information

RED DOT UNITS HEATER-A/C. Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL OPTIONS. Shown with optional louvers

RED DOT UNITS HEATER-A/C. Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL OPTIONS. Shown with optional louvers RED DOT UNITS R-1630 Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL The R-1630 combines powerful heating and cooling with the compact profile you need for tight spaces. It easily

More information

Control and power circuit fusing to meet N.E.C.

Control and power circuit fusing to meet N.E.C. LARGE VOLUME ELECTRIC WATER HEATERS SEV & SEH MODELS Commercial Electric ADVANCED State s new propriety electronic water heater control, provides precise + or - 1ºF temperature control, that is ideal for

More information

National Electrical Code

National Electrical Code National Electrical Code 409.30 Disconnecting Means Disconnecting means that supply motor loads shall comply with Part IX of Article 30. 410.81 Control (A) Disconnection Luminaires (fixtures) or lamp installation

More information

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design Fan motor (PSC or ECM). UL Listed 1 insulation conforms to UL Test 181 and NFPA 90A. Plenum air filter rack. (Filter Optional) Casing has

More information

Comfort Survey Aquila Investment Gr A oup. quila Investment Group.

Comfort Survey Aquila Investment Gr A oup. quila Investment Group. Comfort Survey 2009-2016 2009-2016 Aquila Investment AquilaGroup. Investment Group. COMFORT SURVEY 1. How many years have you lived in this home? How old is the home? 2. How old is your furnace? How old

More information

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts Standard Construction Control Options HEATREX offers a broad range of electrical components for temperature, safety, and power control. For most applications, the Control Option system, described in the

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with NOVATIONt Coil Sizes 08, 12, 14 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED

More information

MODELS B1PA024, 030 AND 036

MODELS B1PA024, 030 AND 036 STELLAR 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.26-N1Y (892) 511.26-N1Y (893) MODELS B1PA024, 030 AND 036 035-11622 GENERAL YORK Model B1PA units are factory assembled heat

More information

Tighe&Bond. Groton Heights School Mechanical Evaluation. 1 Existing Conditions. 1.1 Water Service Entrance

Tighe&Bond. Groton Heights School Mechanical Evaluation. 1 Existing Conditions. 1.1 Water Service Entrance Groton Heights School Mechanical Evaluation TO: FROM: Amy Vaillancourt, Project Manager Harley Langford, Project Manger Jason Curtis, P.E. DATE: February 24, 2016; Revised May 31, 2016 On Monday, December

More information

Installation Instructions

Installation Instructions 50ES--A, 50EZ--A, 50VG--A, B, 50VL--A, B, 50VR--A, 50VT--A, B 604D-- --A, 607C-- --A, B, 607E-- --A, 704D-- --A, 707C-- --A, B, 707E-- --A PA3G -- -- A, PH3G -- -- A, PA4G, PH4G PAD3, PHD3, PAD4, PHD4,

More information

How to reduce exposure to arc flash hazards

How to reduce exposure to arc flash hazards GE Electrical Distribution How to reduce exposure to arc flash hazards Multiple solutions for new and existing facilities imagination at work Multiple Issues Today s power system engineer must not only

More information

Exhibit A. Mechnical, Plumbing, and Electrical Plan Check and Inspection Fees. Total Cost Per Unit FEE TYPES MECHANICAL PERMIT FEES

Exhibit A. Mechnical, Plumbing, and Electrical Plan Check and Inspection Fees. Total Cost Per Unit FEE TYPES MECHANICAL PERMIT FEES Mechnical, Plumbing, and Electrical Plan Check and Inspection Fees MECHANICAL PERMIT FEES FEE TYPES Total Cost Per Unit $ 180.36 Stand Alone Mechanical Plan Check (hourly rate) $ 180 UNIT FEES: Install/Relocate

More information

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT RV Products Division INSTALLATION INSTRUCTIONS FOR 8330-5501 MOUNTING KIT 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330B755 CONTROL BOX KIT (12 VDC HEAT/COOL) 8530-750 CONTROL BOX KIT (24 VAC COOL ONLY)

More information

Requirements for Electrical Installations

Requirements for Electrical Installations BRITISH STANDARD BS 7671:2018 Corrigendum (December 2018) Requirements for Electrical Installations IET Wiring Regulations Eighteenth Edition The Institution of Engineering and Technology and BSI NO COPYING

More information

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508 Electro-HELPS IX Boiler, Submittal Data Sheets These provide the mechanical technical details often required for architects/design engineers, shop drawings, etc. They are also useful in providing additional

More information

Installation Instructions

Installation Instructions Installation Instructions EHMA SERIES ELECTRIC HEATERS FOR PAM3 SERIES PACKAGE AIR CONDITIONERS PHM3 SERIES PACKAGE HEAT PUMPS TABLE OF CONTENTS SAFE INSTALLATION REQUIREMENTS... 2 GENERAL INFORMATION...

More information

FACILITY CONNECTION STANDARD

FACILITY CONNECTION STANDARD FACILITY CONNECTION STANDARD Preface: This Facility Connection Standard applies to any connection to the electric system of Westar Energy, Inc. or Kansas Gas and Electric Company, both doing business as

More information

Smart Grid Tables. Exploring the Electrical Infrastructure Grades 9-12

Smart Grid Tables. Exploring the Electrical Infrastructure Grades 9-12 Smart Grid Tables Exploring the Electrical Infrastructure Grades 9-12 Exploration 1 1. There are three power plants represented on the end of the grid table. List them here. Estimate how much (%) of the

More information

30GN FLOTRONIC II AIR-COOLED CHILLERS

30GN FLOTRONIC II AIR-COOLED CHILLERS 30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed

More information

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual ITC 2000 HEATING CONTROL CABINET Installation & Operation Manual VTI, Incorporated 24 McMillan Way Newark, DE 19713 Phone (302) 738 0500 FAX (302) 738 6594 Revision Level 0.03 Manual No. 90003314 June,

More information

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER 2001829 OPERATIONS AND MAINTENANCE MANUAL Prepared by: 860 Douglas Way PO Box 530 Natural Bridge Station, VA 24579 1.0 SCOPE: This Operations and Maintenance

More information

MARVAIR SCHOLAR III HEAT PUMPS & AIR CONDITIONERS MODELS VAIA & VAISA EXPLODED VIEW PARTS ID

MARVAIR SCHOLAR III HEAT PUMPS & AIR CONDITIONERS MODELS VAIA & VAISA EXPLODED VIEW PARTS ID CABINET SHEET METAL (OUTER PANELS) 1 CABINET SHEET METAL (OUTER PANELS) 1 2 Left Side Door, Includes Exterior Panel and Perforated Interior Panel Right Side Door, Includes Exterior Panel and Perforated

More information

Construction Electrical

Construction Electrical INDEECO offers a broad range of electrical components for temperature, safety, and power control. For most applications, the Control Option system, described in the previous section, makes it easy to specify

More information

SECTION EXTERIOR LIGHTING

SECTION EXTERIOR LIGHTING SECTION 26 56 00 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of exterior luminaries, controls, poles and supports. 1.2 RELATED WORK A. Section 26

More information

www. ElectricalPartManuals. com GADP Ground Fault Indication System Instruction Manual Ground Fault Protection

www. ElectricalPartManuals. com GADP Ground Fault Indication System Instruction Manual Ground Fault Protection Ground Fault Protection GADP Ground Fault Indication System Instruction Manual 7615 Kimbel Street, Mississauga, Ontario Canada L5S 1A8 Tel: (905)673-1553 Fax: (905)673-8472 Toll Free: 1-888-RESISTR 737-4787

More information

48PGD/E/F/L/M/N PG20-28

48PGD/E/F/L/M/N PG20-28 48/50PG-10SB 48PGD/E/F/L/M/N20-28 50PG20-28 SINGLE-PACKAGE COOLING UNITS WITH FACTORY-INSTALLED GAS HEAT SINGLE-PACKAGE COOLING UNITS WITH OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS RV Products Division INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330C755 CONTROL BOX KIT (12 VDC HEAT READY) 8530-750 CONTROL BOX KIT

More information

DOCUMENT TABLE OF CONTENTS

DOCUMENT TABLE OF CONTENTS DOCUMENT 00003 June 16, 2005 TABLE OF CONTENTS DOCUMENT NO. INTRODUCTORY INFORMATION DOCUMENT 00003 TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS SECTION 01011 SECTION 01025 SSP21.1-1 SECTION 01026

More information

DANFOSS OPTYMA PLUS INVERTER UNITS

DANFOSS OPTYMA PLUS INVERTER UNITS Optyma Plus Inverter Condensing Units Danfoss Optyma Plus Inverter Units are designed with the unique benefits of stepless inverter scroll technology resulting in a 20-30% higher energy efficiency in a

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features Electric Pumps Introduction W4100, W4200 & W4300 Condensate Pumps Watson McDaniel s Condensate Return and Boiler Feed Pumps are equipped with Cast Iron bodies and Bronze Impellers. The pump receiver tanks

More information

Jr. Tech (JT-1, 2, 3) Knowledge Areas

Jr. Tech (JT-1, 2, 3) Knowledge Areas Jr. Tech (JT-1, 2, 3) Knowledge Areas The Jr. Tech Level includes technicians that are just entering the business and are in the beginning stages of their HVAC-R training and development. Over this period

More information

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS 50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York

More information

UEE30811 Q-Tracker Work Tasks

UEE30811 Q-Tracker Work Tasks UEE30811 Q-Tracker Work Tasks UEENEEC020B Participate in electrical work and competency development activities Q-Tracker requirements: 40 hours of practical training. 1. Comply with electrical industry/enterprise

More information

2 X 1996 Wartsila 18V mw Each 50hz HFO Generator Sets

2 X 1996 Wartsila 18V mw Each 50hz HFO Generator Sets 2 X 1996 Wartsila 18V26 5.125mw Each 50hz HFO Generator Sets The responsibility for any and all additional charges is the purchasers. 2 x WARTSILA 5 MW Power plant 2 Units of Wartsila 18V26 @ 5 MW each,

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

Paragon. Induced Draft, Counter Flow Optional Accessories

Paragon. Induced Draft, Counter Flow Optional Accessories ANTIFREEZE PACKAGE / RESISTANCE HEATING OPTION The antifreeze package is supplied to provide protection against freezing of standing water in the cooling tower sump due to shutdown during winter operation.

More information

30GT FLOTRONIC AIR-COOLED CHILLERS

30GT FLOTRONIC AIR-COOLED CHILLERS 30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed

More information

Electrical Inspection Service & Distribution

Electrical Inspection Service & Distribution 0911 Distribution Panels & Switchgear Equipment, conduit, feeders, and grounding 480 Volt Switchboard: This switchboard contains the utility meter and two main, service, circuit breakers. One circuit breaker

More information

50TM COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS 50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form

More information

Company Directive STANDARD TECHNIQUE : SP1N

Company Directive STANDARD TECHNIQUE : SP1N Company Directive STANDARD TECHNIQUE : SP1N Heating, Dehumidification and Ventilation of Switch Rooms and Control Rooms at Grid, Primary and Major Network Substations ST:SP1N October 2013-1 of 9 - Document

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-23 82 00.00 20 (February 2016) ----------------------------------- Preparing Activity: NAVFAC Superseding UFGS-23 82 00.00 20 (November 2008) UNIFIED FACILITIES GUIDE

More information

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER 2001927 Prepared by: 860 Douglas Way PO Box 530 Natural Bridge Station, VA 24579 1 1.0 SCOPE: This

More information

ELECTRICAL POWER SYSTEMS

ELECTRICAL POWER SYSTEMS Scope The various Codes applicable to the University's electrical power system are mainly based upon a model of a single utility service, connected to a single premise. The University s electrical system,

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 230593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Balancing Air Systems: a. Constant-volume air systems. b. Variable-air-volume systems. 2.

More information

Monitoring of Electrical Equipment Failure Indicators and Alarming

Monitoring of Electrical Equipment Failure Indicators and Alarming Past, Present and Future Maintenance Practices: Monitoring of Electrical Equipment Failure Indicators and Alarming Author: Gabe Paoletti, P.E. Eaton Corporation Senior Member, IEEE gabrieljpaoletti@eaton.com

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump

More information

Product Data. 49FH, 49FP, 49BF, 49WS, 49BG Humidifiers

Product Data. 49FH, 49FP, 49BF, 49WS, 49BG Humidifiers HEATING & COOLING Product Data 49FH, 49FP, 49BF, 49WS, 49BG Humidifiers Model 49FH Model 49WS Model 49BF Model 49FP Model 49BG All Carrier humidifiers are designed for easy installation and quiet operation

More information

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module FIRE ALARM CONTROL EQUIPMENT Addendum October 2006 Instructions for new style EN54-4 Power supply unit module MXLK-05 Issue 2.0 June 2007 INSTALLATION Safety Suppliers of articles for use at work are required

More information

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6 INTRODUCTION This service manual covers the installation, operation, maintenance and service of this ice machine. Table of Contents SPECIFICATIONS Page 2 FOR THE INSTALLER Page 3 FOR THE PLUMBER Page 4

More information

CxA to Answer this Section

CxA to Answer this Section EXHIBIT 01 91 13-3, SAMPLE Construction checklist items are to be completed as part of initial checkout and subsequent startup, preparatory to Functional testing. This checklist does not take the place

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

Drexan Energy Systems Inc.

Drexan Energy Systems Inc. Drexan Energy Systems Inc. SPECIFICATION Self-Regulating Heating Cable PipeGuard Warm Page 1 of 8 CONTENTS 1. SCOPE 2. PRODUCTS 3. TESTING 4. MARKINGS 5. PACKING 6. GENERAL 7. INSTALLATION AND COMMISSIONING

More information

Please refer to the drawing and notes for each particular plan view. Site Plan S1-1 Site Drawing. Electrical E1-1 Main Electrical Drawing

Please refer to the drawing and notes for each particular plan view. Site Plan S1-1 Site Drawing. Electrical E1-1 Main Electrical Drawing The property that I discuss is an actual property that I helped to build. My position was as the Facility/Project Manager while the building was under construction. I worked very closely with the Senior

More information