August 2004 AB0804. Accessories Book. Fantech I Your Ventilation Solutions Company
|
|
- Ashley Brooks
- 5 years ago
- Views:
Transcription
1 ugust ccessories ook Fantech I Your Ventilation Solutions ompany
2 Supply/xhaust Fans ombination xhaust Grill and Light VL Vent light combination. Smallscale grill with 0 watt halogen light (MR1 bulb included). UL approved for wet locations. Kit includes prewired grill light assembly with back-draft damper, 0 watt halogen bulb, and to - inch reducer for connecting ductwork.oes not include fan. May also be used as a light only. Roof ap Inline Fan VL 0w Halogen Light 1 /2 0w Halogen 1 / / uct connections are / smaller than duct size. Fixed xhaust Grills G Fantech s esigner Grill. low profile, fixed circular plastic exhaust grill. Included with the grill is a matching diameter galvanized mounting collar with nailing strip. G Fantech s esigner Grill/ amper. Same as G with integrated backdraft damper. ø ø ø ø G G UP# ø / / / 1 / 1 / ø / / / / uct connections are 1 / smaller than duct size. 2 I Fantech ccessories ook G G UP# 9 9 ø / / / 1 / 1 / ø / / uct connections are 1 / smaller than duct size. ll Fantech grills (except VL) are available in bulk packs. Suggested maximum airflow for Fantech xhaust Grills is: 0FM; FM, FM, 200FM.
3 Supply/xhaust Fans djustable xhaust Grills PG Fantech s Plastic Grill. low profile, adjustable intake/ exhaust circular grill. Included with the grill is a matching diameter galvanized mounting collar with nailing strip. PG Plastic Grill includes integrated backdraft damper. low profile, adjustable intake/exhaust circular grill. Included with the grill is a matching diameter galvanized mounting collar with nailing strip. ø ø ø ø PG PG PG PG UP# ø 1 /2 1 / / 9 1 /2 / / / / 1 1 /2 1 / 1 / 1 / ø / / / / / / / / uct connections are 1 / smaller than duct size. MG/MG Fantech s Metal Grill. White powder coat finish. low profile, adjustable intake/ exhaust circular grill. Included with the grill is a matching diameter galvanized mounting collar with nailing strip. PG PG UP# ø / / / / 1 / 1 / ø / / / / uct connections are 1 / smaller than duct size. djustable Supply Grills MGS Fantech's Metal Supply Grill. White powder coat finish. low profile, adjustable, circular supply grill. Included with grill is a matching diameter galvanized mounting collar with nailing strip. MG includes integrated backdraft damper ø ø ø UP# MG 00 MG 00 MG 00 MG 00 MG 0 MG 0 ø / / 1 /2 9 1 / / / / / / / 1 /2 / 1 / / uct connections are 1 / smaller than duct size. 1 / 1 / 1 / 1 / 1 1 /2 ø / / / / / / / / / ø MGS MGS MGS MGS UP# ø / 1 / 1 /2 9 1 / / / / / 1 / 1 / 1 / 1 / ø / / / / / / / / uct connections are 1 / smaller than duct size. Fantech I Your Ventilation Solutions ompany I
4 ontrols & Switches Pressure Switches ryer boost switch. utomatic pressure switch allows for fully automatic operation of dryer booster fan. Fan runs for minutes when positive pressure is sensed in the duct line then shuts off and turns on again as needed. Switch suitable for 11 volt supply. 2 amp rating. Variable Speed ontrollers S Series Slide type variable speed controller with on/off switch. White ecora-style switch plate and screws included. Fits standard single gang box. Note: S protrudes /-inch from wall. UP #0 S S UP# 0 0 Volts mps 1 /2 / W Series FPS 1 W1 and W2 (2 wire) rotary type variable speed controller with on/off switch. rushed aluminum switch plate and screws included. Fits standard single gang box. W1H ( wire) contains all the features as the W1 with a high speed bypass. Pressure switch. djustable between 0.0 to 1.0 water differential pressure. Using either positive or negative pressure sensing for duct line. Switch suitable for 11 volt supply. amp rating. UP# W 1 00 W 1H 00 W 2 00 Volts mps UP #0 RP Series / / Heavy duty rotary type variable speed controller with on/off switch. rushed aluminum switch plate and screws included. 1 / 1 /2 RP RP 1 RP 2 UP# Volts mps 1 I Fantech ccessories ook
5 ontrols & Switches Timers F 0M lectronic push button timer. Select from, 20, 0 and 0 minute timed operation of fan. Includes ecora style white switch plate and screws. Fits standard single gang box. Ideal for multiple switching locations. Switch suitable for 11 volt supply. 20 amp rating. UP #200 ehumidistat ontroller FH 20 Wall mounted dehumidistat. djustable between 20% and 0% relative humidity. Switch suitable for up to 11 volt supply.. amp rating. White. UP #020 F 0M Mechanical crank timer. Select from 1 to 0 minutes of timed fan operation. Switch suitable for 11 or 20 volt supply. amp rating. Use with ecora-style or standard white face plate (not included). Suitable for multiple switching locations. ttic Thermostat FT Thermostat for use with attic ventilation systems. djustable between 0º and 10ºF. Switch suitable for 11 volt supply. amp rating. UP #291 UP #00 FL 0 Fan/Light delay timer switch. llows continuous operation of the fan for up to 1 hour after light switch is turned off. Switch suitable for 11 volt supply. amp rating. rushed aluminum switch plate and screws included. Suitable for single switching location. UP #00 ir Screen ontrols S S ast metal and plastic plunger style door switch. Switch suitable for 11 or 20 volt supply. 1 amp rating. esigned for use with Fantech ir Screens -00 through S-0 UP #291 RTS2 1-minute timer with L light for use with the majority of Fantech residential Heat Recovery and nergy Recovery Ventilators.Works as an override switch to turn HRV or RV on high speed for 1 minutes. Up to four timers can be used. Install in bathrooms, kitchen or laundry where ever easy-access wall control is needed. 2 volt. UP # S TS Two-stage thermostat for heated ir Screens. Switch suitable for 11 or 20 volt supply. amp rating. UP #29 Fantech I Your Ventilation Solutions ompany I
6 ontrols & Switches HRV/RV ontrols F IGITL ISPLY Shows Indoor Humidity Level HUMIISTT ONTROL ehumidistat is ideal for use in energy efficient houses where indoor humidity (during the heating season) is higher than outdoor levels. High humidity is a major cause of structure damage and IQ problems such as mold and mildew. OVRRI TIMR When pressed, unit will provide high speed ventilation for one 1, 0 or 0 minute period. MINTNN LIGHT Light comes on when it s time to clean unit. POWR On/Off and Reset MOS Select Intermittent, Recirculation or ontinuous Ventilation Modes ontrol multiple functions of your Fantech HRV/RV with one slimline wall control. Two-wire connection simplifies installation. Use one F per HRV/RV installed. OVRRI SP ONTROL Push to select override speed of unit. YL ONTROL Set unit to cycle on 1, 20, or 0 minutes every hour MO SP Set Unit to Low, Medium or High Speed F2 MH 1 Multi-function wall control for use with Fantech SHR/VHR Heat Recovery units or SR nergy Recovery units. Two-wire connection simplifies installation. Similar to F (shown above) without recirculation mode. UP# 11 2-wire low voltage dehumidistat control with rotary dial. Just turn the dial to set the humidity level. Multiple units can be used with Fantech HRV's. Install in bathrooms, kitchen or laundry for easy access. UP# 1 MH 2 ehumidistats QS 1 ir Quality Sensor for use with Fantech HRV/RV systems. utomatically senses pollutants and activates HRV/RV to high speed if levels exceed normal condition. Features indicator light that changes color to indicate level of pollution in the home. Pushbutton override switch sets unit to run 1,2 or hours at high speed. Three-position for efficient operation. Use one per HRV/RV system. MPG 0 -wire low voltage dehumidistat control with power indicator light and on/off switch. ial lights up when dehumidistat turns unit to high speed. Use one per HRV system. (o not use with F.) UP# 1 Magnehelic Pressure Gauge for measuring and balancing airflow. (0.0"/2000-O).Shown here with optional accessories. For complete list of available accessories see Fantech Price List. I Fantech ccessories ook UP# UP# 209
7 uct Supplies Iris ampers IR Iris dampers for quiet, precise balancing of ventilation systems. ampers include calibrated airflow measuring devise. ackdraft ampers RSK ackdraft dampers with galvanized steel collar and lightweight aluminum damper blades. Spring loaded for positive closure. ir Flow IR IR IR IR IR IR IR 1 IR 20 IR 2 UP# / 2 / 1 /2 1 / / / / 2 1 / / 2 / 2 / 1 / 2 / 2 / uct connections are 1 / smaller than duct size. RSK RSK RSK RSK RSK RSK RSK 1 RSK 1 UP# / 1 / 1 / 1 / / / uct connections are 1 / smaller than duct size. Lint Trap for ryer oosting LT Paintable galvanized metal lint trap for dryer boosting applications. Use when duct length between dryer and booster fan is less than 1 feet. Fits -inch duct. Features pull out door with view window, removable lint filter for easy cleaning and 1 /2-in flange for flush mount installation. 1 / 1 / 2 1 /2 UP # /2 Fantech I Your Ventilation Solutions ompany I
8 uct Supplies Sheet Metal dapters FY Y adapter for circular duct. onstructed of galvanized sheet metal. KR Increaser or reducer for circular duct. onstructed of galvanized sheet metal. FY FY FY FY FY FY UP# uct connections are 1 / smaller than duct size. Roof urbs WI/I Prefabricated roof curbs reduce installation time by ensuring compatibility of the fan and curb. urbs feature a welded 1 gauge galvanized steel construction, -inch cant, insulation and wooden nailing rail. Standard height is -inches. 1 / /2 1 1 /2 1 / / /2 WI I 1Q0 UP# /2 FNS R R XL R XL KR KR KR UP# / 1 / uct connections are 1 / smaller than duct size. Silencers for Round uct L 1 / 1 /2 1 / Galvanized steel silencer for use in kitchen range hood ventilation and other applications were noise is a concern. Fantech silencer can typically reduce the perceived sound level of the system by more than 0%. Units feature rubber seal on inlet and outlet. Note:The recommended connector for the L is the F-1 (see page 9). L L L L L L L 1 UP# Outside ø 9 1 / 1 /2 1 1 / 2 Length 2 / 2 / 2 / 2 / 1 /2 1 /2 1 /2 uct connections are 1 / smaller than duct size. 1 1 /2 / L L L L L L L 1 Sound ata (Suppresion d Frequency ands Hz) I Fantech ccessories ook
9 uct Supplies Round Flexible uct FIT lamps for ircular uct Flexible round insulated duct. vailable in 2-foot lengths. UL listed. FIT FIT FIT FIT FIT UP# Plastic duct clamps. For use with flexible duct, easy to install locking slide clamps. UP# Inlet Guards IG lbows FL Wire ring inlet guards used to prevent foreign objects from entering duct line. Zinc chromate plated steel. IG IG IG IG IG IG UP# Heavy-duty plastic 90º mounting collar/elbow for use in 2 x stud walls. Use with -inch duct. With half-inch drywall lip already set, just nail in place and connect duct. Low depth profile makes this elbow the perfect solution for sidewall ventilation within a wall partition. UP #9 F 1/2 Stabilizing mounting clamps. Two inch wide galvanized steel bands lined with neoprene. an be used for suspended installation of fan. For use with rigid duct work (sold in pairs). F-1 connector kit for L or other uropean 1mm duct. F /1 1 /2 imensional information in inches. Pull-Out Hanging Tabs F F F F F F F -1 UP# / F F UP# Round metal elbows adjust from 0º to 90º. Ideal for installations where space is at a minimum. 1 /2 / 9 1 / 9 1 / Fantech I Your Ventilation Solutions ompany I 9
10 xterior Vents Roof aps R Roof ap with damper flap closure, duct connection and screened exhaust opening. Stainless steel or copper roof caps available by special order. all for more information. Soffit Vent UV Plastic soffit vent for use with or -inch duct. Note: Use F or F (shown on page 9) for installations where flex duct is used. UP #1 R R R R R R UP# / / 1 / Material luminum Galvanized Steel Galvanized Steel Galvanized Steel Galvanized Steel Galvanized Steel uct connections are 1 / smaller than duct size. Outdoor Louvers & Weather Hoods OM P 1 / Louvered Vents HS Plastic louvered shutter with duct connection. 2 1 / Outdoor Louvers for duct (pair). Includes one supply and one exhaust louver. White plastic. F 1 1 / 1 / OM P UP# / 1 / 1 / 9 1 / 11 /1 uct connections are 1 / smaller than duct size. OM/FML F F OM M Pair of metal outdoor hoods for duct. Includes one exhaust and one supply hood. Prepainted white aluminum. FML s include a single prepainted aluminum hood for exhaust applications. Sizes to fit to duct. HS W HS W HS W UP# /2 1 /2 1 /2 / / uct connections are 1 / smaller than duct size. VK Plastic louvered shutter with duct connection. Includes tab collar for duct connection. F 1 /2 / / OM M FML FML FML UP# I Fantech ccessories ook / 11 /1 / /1 /1 /1 1 /2 /1 1 1 / uct connections are 1 / smaller than duct size. 1 / 1 1 / VK 2 VK 0 VK UP# /2 1 1 /2 1 1 / /2 1 1 /2 1 1 /2 1 /2 1 /2 1 1 /2 1 / 1 1 /2 1 /2 1 /2 uct connections are 1 / smaller than duct size. F 1 1 / 1 / F 9 1 / /2 1 1 /2
11 Range Hood Liners SHL/SGHL SHL Series range hood liners feature all stainless steel construction. SGHL liners feature stainless steel face with galvanized steel housing. oth styles have built-in infinite speed control for the fan, washable aluminum filters and dimmable halogen lights (purchase separately). SHL Series available in ", 2" and " widths. SGHL Series available in 0" and " widths. UL approved. Kitchen Ventilation the quiet, efficient way. FK Inline Fan Hot steam and odor exhausted through roof vent L Silencer Rigid uct SHL/SGHL Range Hood Liner RSK ackdraft amper Shown above: (front to back) SGHL 0, SGHL and SHL Shown right:typical range hood installation using Fantech s SHL/SGHL Range Hood Liner, RSK ackdraft amper, L Silencer and Inline Fan. Hood Liner can also be used with mounted fans. See chart for correct sizing information. Front of Hood immable Halogen Lights Speed/Light ontrols Front of Hood immable Halogen Lights Speed/Light ontrols Washable luminum Filters SHL Series imensional Information UP# SHL SHL 2 SHL /2 0 1 /2 1 /2 uct connections are 1 / smaller than duct size. Recommended Fans for SHL Series Fan Use With Location Mounting irflow SHL (s) at 0" FX FX XL FX FX XL FK XL FK FK XL FK XL* RVF XL R XL R XL SHL /2 SHL /2 SHL SHL SHL /2 SHL SHL /2/ SHL SHL /2 SHL /2 SHL /2/ wall roof/wall roof/wall " Typical irflow Typical airflow is an estimate based on a system with 20' of duct, two 90 elbows, a backdraft damper, roof cap and filters. * Requires larger speed control. ontact Fantech ustomer Service for recommendations. Washable luminum Filters SGHL Series imensional Information SGHL 0 SGHL UP# /2 1 /2 1 1 uct connections are 1 / smaller than duct size. Recommended Fans for SGHL Series Fan Use With SGHL (s) Location Mounting irflow at 0" FX ** FX XL FX XL FK XL RVF ** RVF XL RVF XL R ** R XL R XL SGHL 0 SGHL 0/ SGHL 0/ SGHL SGHL 0 SGHL 0/ SGHL SGHL 0 SGHL 0/ SGHL wall wall wall roof/wall roof/wall roof/wall Fantech I Your Ventilation Solutions ompany I 11 1" Typical irflow Typical airflow is an estimate based on a system with 20' of duct, two 90 elbows, a backdraft damper, roof cap and filters. ** Fans will meet most local code requirements but will produce less than Fantech's recommended ventilation rate of 0 cfm per foot of hood width.
12 Index Supply/xhaust Grills ombination xhaust Grill & Light VL... 2 Fixed xhaust Grills G... 2 G... 2 G... 2 G... 2 djustable xhaust Grills MG... MG... MG... MG... MG... MG... PG... PG... PG... PG... PG... PG... djustable Supply Grills MGS... MGS... MGS... MGS... ontrols & Switches Pressure Switches... FPS... Variable Speed ontrollers RP... RP 1... RP 2... S... S... W 1... W 1H... W 2... Timers F 0M... F 0M... FL 0... RTS 2... ehumidistat ontroller FH ttic Thermostat FT... ir Screen ontrollers S S... S TS... For more information contact: web: info@fantech.net United States 1 Northgate lvd. Sarasota, Florida 2 Phone: 00--; Fax: ; HRV/RV ontrols Intellitek ontrol F... F2... ir Quality Sensor QS 1... ehumidistats MH 1... MH 2... Pressure Gauge MPG 0... uct Supplies Iris ampers IR... IR... IR... IR... IR... IR... IR 1... IR IR 2... ackdraft ampers RSK... RSK... RSK... RSK... RSK... RSK... RSK 1... RSK 1... Lint Trap for ryer oosting LT... Sheet Metal dapters KR... KR... KR... FY... FY... FY... FY... FY... FY... Silencers For Round uct L... L... L... L... L... L... L 1... Roof urbs WI... I 1Q0... anada 0 Kanalflakt Way ouctouche, N S M Phone: 00--; Fax: --11; ircular uct lamps Mounting lamps F... 9 F... 9 F... 9 F... 9 F... 9 F... 9 F lbows F... 9 F... 9 FL... 9 Round Flexible uct FIT... 9 FIT... 9 FIT... 9 FIT... 9 FIT... 9 Inlet Guards IG... 9 IG... 9 IG... 9 IG... 9 IG... 9 IG... 9 xterior Vents Louvered Shutters HS W... HS W... HS W... VK 2... VK 0... VK... Roof aps R... R... R... R... R... R... Outdoor Hoods OM P... OM M... FML... FML... FML... Soffit Vents UV... Range Hood Liners SGHL SGHL SHL SHL SHL Fantech, reserves the right to modify, at any time and without notice, any or all of its products features, designs, components and specifications to maintain their technological leadership position. rt.# Fantech, Inc.ll Rights Reserved.
March 2003 AB0303. Accessories Book. Fantech I Your Ventilation Solutions Company
March 200 00 ccessories ook Fantech I Your Ventilation Solutions ompany Supply/xhaust Fans ombination xhaust Grill and Light VL Vent light combination. Smallscale grill with 0 watt halogen light (MR1 bulb
More informationHEAT RECOVERY AND ENERGY RECOVERY VENTILATORS
HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS ENERGY-SAVING VENTILATION SOLUTIONS TO IMPROVE INDOOR AIR QUALITY Quality Features Built Into Every Model Compact
More informationAir in Motion. Fan Guide Book February 2004 FB-0204
Air in Motion Fan Guide Book February 2004 FB-0204 Find the Fan that Fits Page by page, product by product, this Fantech Guide Book offers you ventilation solutions to meet a wide variety of residential
More informationAir in Motion. Fan Guide Book. January 2001 FB-0101
Air in Motion Fan Guide Book January 2001 FB-0101 Find the Fan that Fits Page by page, product by product, this Fantech Guide Book offers you ventilation solutions to meet a wide variety of residential
More informationIAQ VENTILATION SOLUTIONS
IAQ VENTILATION SOLUTIONS HEAT RECOVERY VENTILATORS ENERGY RECOVERY VENTILATORS WHOLE HOUSE HEPA FILTRATION IMPROVING INDOOR AIR QUALITY THROUGH BETTER VENTILATION July 2006 IAQ0706 www.fantech.net What
More informationIAQ VENTILATION SOLUTIONS
IAQ VENTILATION SOLUTIONS HEAT RECOVERY VENTILATORS ENERGY RECOVERY VENTILATORS WHOLE HOUSE HEPA FILTRATION I M P R O V I N G I N D O O R A I R Q U A L I T Y T H R O U G H B E T T E R V E N T I L A T I
More informationResidential Fans & Air Purifiers
Residential Fans & ir Purifiers ESSORIES Fan ccessories Mounting lamps for Rigid Duct M mounting clamps are designed for use with rigid duct. The foam neoprene layer creates an air tight and solid installation
More information5 year fan housing and motor warranty
MODEL SWF SIDEWALL CENTRIFUGAL FAN MODEL FEATURES Exhaust air up to 416 CFM with static pressure capabilities to 1.5 w.g. Galvanized steel casing with black backed enamel coating Pre-wired junction box
More informationVentilation Solutions. Bathrooms
Ventilation Solutions 2 We give you choices Designing a bath involves many decisions that will ultimately affect its look and function, whether it be a busy family bathroom or a small guest bath with limited
More informationFADE PrioAir FG EC RVF DPV FR FRD
Fan Solutions Fan Overview FG FSD CVS FG EC FDE Prioir RVF DPV FR FRD FKD RE 2 Fans Fans 3 FG Series Inline Centrifugal Fans 4" 12" 135 940 cfm 100% LEK-FREE HOUSING The two halves of the housing are joined
More informationSER Models. SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT
SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will operate if connected
More informationThe PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty
MODEL OVERVIEW The POWERVENT (PV) series of direct drive centrifugal in-line duct ventilation fans consists of twelve model sizes 4, 5, 6, 8, 10 and 12.4 respectively. All models are designed for direct
More informationSHR & VHR Models. SHR & VHR Series. Installation Manual. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT
Installation Manual IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will operate if connected to any other
More informationSER Models. SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT
SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will operate if connected
More informationREFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS
*s are Subject to Change without Notice.* REFLECTOR PANS FOR HINGED ELEMENTS Heavy Chromed Steel Description 2-1040 6" UNIVERSAL $2.19 2-1041 8" UNIVERSAL $2.89 2-1050 6" GE/HOTPOINT $2.39 2-1051 8" GE/HOTPOINT
More informationPHRV(R) Series. Heat Recovery Ventilator PHRV 140 PHRV 150 PHRV 200 PHRVR 155 PHRVR 160 PHRVR 205 PHRVR 210 PHRVR 305
PHRV(R) Series Heat Recovery Ventilator PHRV 140 PHRV 150 PHRV 200 PHRVR 155 PHRVR 160 PHRVR 205 PHRVR 210 PHRVR 305 IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation,
More informationVHR SERIES VHR 704. Installation Manual. Heat Recovery Ventilator INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Installation Manual IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will operate if connected to any other
More informationInstallation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)
Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics RNC Series Models RNC95 RNC155 RNC200 RNC10 RNC20 RNC120D RNC5-TPD Residential Heat Recovery Ventilators (HRV) Manufactured
More informationVentilation Solutions IAQ Canada
Ventilation Solutions IAQ Canada 2 IAQ Canada Indoor Air Quality Keep your family safe What s All The Talk About Indoor Air Quality? What The Experts Say: You ve heard it on TV and read about it in magazines.
More informationResidential Fans & Air Purifiers
Residential Fans & Air Purifiers DUCT FANS MFT MIXED FLOW IN-LINE FANS MFT Mixed Flow In-Line Fans are designed for residential and light commercial ventilation applications. These compact, powerful, and
More informationOutside Air Requirements... SOLVED!
Outside Air Requirements... SOLVED! Advancing VentilationTM refresh-0918 September 2018 The Whole Building Ventilation Standard With houses and buildings being built as tightly as possible, we are plagued
More informationFeaturing Vent Lights and Premium Grilles
Featuring Vent Lights and Premium Grilles The World s Leading Producer of Air Movement Products November 2013 Premium Choice Bathroom Fans For YOUR Family & YOUR Home Today s homes are built to be tighter
More informationEnergy Recovery Ventilators
Energy Recovery Ventilators ERV-150 ERV-200 IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will operate
More informationResidential Fans & Air Purifiers
Residential Fans & Air Purifiers HOME VENTILATION SOLUTIONS Installation Tips DVK100B fans should be mounted at least 15 linear feet from dryer. Each 90-degree elbow is equivalent to 5 linear feet of duct.
More informationResidential Fans & Air Purifiers
Residential Fans & Air Purifiers DUCT FANS EXT EXTERNAL MOUNT DUCT FANS EXT External Mount Duct Fans offer the perfect solution when space restrictions prevent the use of in-line duct fans. EXT fans provide
More information10-year industry best core warranty. 5-year warranty on balance of unit.
MODEL TR MODEL FTURES MERV-8 filters Less than 1 watt stand-by power consumption Transformer/relay package allowing simple on/off control Plastic double collars for 6 or 8 direct duct connection (TR300
More informationHeating Products M arch 2012
Heating Products M arch 2012 Broan Heaters Broan Heaters. Put the comfort you want right where it s needed. 2 Broan Heaters Why spot heating makes sense in your home. Think about it you hastily get ready
More informationResidential Fans & Air Purifiers
Residential Fans & Air Purifiers BATHROOM EXHAUST FANS AEROFAN BATHROOM FANS Whisper-quiet, two-speed operation sets the AeroFan apart from the competition. These traditional in-ceiling fans are engineered
More informationProduct Catalog Commercial Solutions US Edition
Product Catalog Commercial Solutions US Edition 2 Introduction Quality products, reliable service and leaders in innovation For more than 30 years, Fantech has been researching, designing and bringing
More informationWholesale Products Catalog
Since 1982 Wholesale Products Catalog Direct Sales to: Builders Contractors Trades Utilities Agencies ESCOs efi.org/wholesale Ventilation Equipment Air Sealing Products Spray Foam Kits Energy Efficient
More informationProduct Catalog Commercial Solutions US Edition
Product Catalog Commercial Solutions US Edition 2 Introduction Quality products, reliable service and leaders in innovation For more than 30 years, Fantech has been researching, designing and bringing
More informationLight commercial models
Installation Manual Item #: 422468 Rev Date: 051414 Light commercial models Energy Recovery Ventilators SER 5504 SER 8504 SER 11504 Your ventilation system should be installed in conformance with the appropriate
More informationHeat or Energy Recovery Ventilation System
INSTALLATION MANUAL Heat or Energy Recovery Ventilation System MODELS: FC80 HRV & FC80 ERV This device MUST be installed by a qualified agency in accordance with the manufacturer's installation instructions.
More informationMODELS SP & CSP. Ceiling & Inline Cabinet Exhaust Fans. Making a Sound Difference with Silent Solutions. Ceiling. Inline.
MOLS SP & SP eiling & Inline abinet xhaust Fans Making a Sound ifference with Silent Solutions eiling Inline R November 00 eiling and abinet xhaust Fans Great things come in small packages, as do our ceiling
More informationFor performance and dimensional data, see back page.
Continental Fan s AXC in-line centrifugal duct fans are designed for residential, commercial and industrial ventilation applications. The uiet and efficient backward-curved impeller is capable of developing
More informationExhaust Makeup Air System What goes out, must come in
Exhaust Makeup Air System What goes out, must come in Exhaust Makeup Air System What goes out, must come in so says the building code 7 4 8 Wall Intake Hood, FML Shutoff Damper, ADC Makeup Air Fan, FG
More informationKHP Models. KHP Series. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT
KHP Series Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will operate if connected
More informationMODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS
With S&P s TR & TRC (total recovery) Series for all climates, stale room air is exhausted and fresh outdoor air is brought back into the house. These two air streams are directed through a highly developed
More informationSAFETY AND INSTALLATION MANUAL MODEL 8100
SAFETY AND INSTALLATION MANUAL ENERGY RECOVERY VENTILATORS MODEL 8100 Provides year-round fresh air Recovers 77% of the apparent heating or cooling energy from the exhausted air See Warnings Page 3 Table
More informationRead and Save These Instructions All Hoods Must Be Installed By A Qualified Installer
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationBathroom Ventilation
Bathroom Ventilation featuring Also with TD-MIXVENT and PV-POWERVENT Bathroom Exhaust Kits August 2015 1 The Fan of your CHOICE To protect the two most valuable investments of your life, your home and
More informationVentilation Solutions Laundries. fantech
Ventilation Solutions Laundries 2 Laundries A New Day - and a New Name for Dryer Exhaust Fans Remember the good old days when laundry spaces were designed so that clothes dryers could be vented directly
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationMake-Up Air Systems. Performance. Model DGK, DG, DGX
DGK, DG, DGX 96 Make-Up ir Systems Direct Fired Gas Heat DGK-15-25 DG-10-20 -30 DGX-12-22 -32 *DGX with PDX-12-22 -32 est vailable Program 5 Days 10 Days 15 Days * est vailable based on size and capacity
More informationCVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636.
VS Venting System for ategory II, III, and IV gas appliances. Listed to UL-1738 and UL S636. PelletVent venting system. Listed to UL 641, UL S609, and UL/ORD 441. Unitized venting system for DirectVent
More informationTR Series - The Ultimate ERV
TR Series The Ultimate ERV Total Recovery for All Climates Featuring Vent Lights and Premium Grilles Fans s for f Life! The World s Leading Producer of Air Movement Products TR_0810 Indoor Air Quality
More informationPW 150 / PW 100. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT INSTALLATION, OPERATION AND MAINTENANCE MANUAL 1
PW 150 / PW 100 Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will operate if
More informationSH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT
SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will
More informationIndirect Gas-Fired Make-Up Air
Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up
More informationModular Supply Make-Up Air Unit
Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features
More informationVERTICAL FAN COIL UNITS
VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote
More informationTechnical and Dimensional Data. Saf-T Vent SC Plus
Technical and Dimensional Data Saf-T Vent S Plus 3"/5" & 4"/7" oncentric Reduced learance Double Wall for Special Gas Vent and/or Sealed ombustion Systems lso For Venting Listed Gas or Oil Fired ppliances
More informationFresh and clean... even when it isn't laundry time.
90 Clean Fresh and clean... even when it isn't laundry time. Clean 9 92 Clean A Residential Laundry with a washer and a dryer Fantech inline Dryer Exhaust Duct Power Ventilators (DEDPV), (previously known
More informationVentZone Systems VentZone Zoned IAQ with Heat Recovery Kits
RESIDENTIAL SYSTEM SOLUTIONS VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits VentZone Zoned IAQ Kits with Heat Recovery combine a Standard Residential Heat Recovery Ventilator (HRV) with residential
More informationGREEN REFRIGERANT R-410A
PH-SERIES PCKGED HET PUMPS Cooling Capacities: 2, to 6, Heating Capacities:, to 2, SEER:. HSPF: GREEN REFRIGERNT R-4 FRONT (INDOOR IRFLOW) END OF UNIT CK (OUTDOOR IRFLOW) END OF UNIT Standard Engineered
More informationModel 8120 and 8126 Safety & Installation Instructions
Ventilation Controller Model 8120 and 8126 Safety & Installation Instructions FAMILIARIZE YOURSELF WITH THE INSTALLATION INSTRUCTIONS BEFORE STARTING DANGER ATTENTION INSTALLER: To prevent serious injury
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationVentilation Solutions IAQ Canada
Ventilation Solutions IAQ Canada 2 Ventilation Solutions IAQ Ventilation Solutions IAQ 3 Indoor Air Quality Keep your family safe Safeguard Your Home Three easy steps Your home should be safe and comforting,
More informationSER Series. fantech. Installation Manual. Energy Recovery Ventilators. ser 1504 ser 1504n ser 2004 ser 2004n ser 3204d ser 3204n
Installation Manual Item #: 401455 Rev Date: 2015-05-12 SER Series Energy Recovery Ventilators ser 1504 ser 1504n ser 2004 ser 2004n ser 3204d ser 3204n Your ventilation system should be installed in conformance
More informationContents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...
Contents How to choose Recovery Ventilation type?............................................3 How do HRV, ERV and TRV Systems work?............................................4 Types of installations..............................................................5
More informationSER150. Installation Manual. Energy Recovery Ventilators
Installation Manual Item #: 427470 Rev Date: 2018-12-03 SER150 Energy Recovery Ventilators Your ventilation system should be installed in conformance with the appropriate provincial/state requirements
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationResidential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators
Residential and Commercial HRVs & ERVs Heat Recovery Ventilators & Energy Recovery Ventilators Residential HRVs - Horizontal Recirculating Defrost SUPERVENTOR SERIES Color coded collars easily identify
More informationRead and Save These Instructions All Hoods Must Be Installed By A Qualified Installer
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationHRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.
HRV / ERV Heat or Energy Recovery Ventilation Systems You need fresh air, so does your home. Control Your Indoor Air Quality Following the energy crisis of the 1970s, we tended to insulate our homes and
More informationThe 2018 Ventilation Extravaganza. Rick Karg Residential Energy Dynamics 2018
The 2018 Ventilation Extravaganza Rick Karg Residential Energy Dynamics 2018 Topics Multifamily Manufactured homes Equipment options Controls Ducting Low-cost strategies Best practices 2 Multifamily 3
More informationSER Series. Installation Manual. Energy Recovery Ventilators SER 1504 SER 2004 SER 3204D
Installation Manual Item #: 401455 Rev Date: 2016-08-15 SER Series Energy Recovery Ventilators SER 1504 SER 2004 SER 3204D Your ventilation system should be installed in conformance with the appropriate
More informationVentZone Systems VentZone Zoned IAQ with Energy Recovery Kits
RESIDENTIAL SYSTEM SOLUTIONS VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits VentZone Zoned IAQ Kits with Energy Recovery combine a Standard Residential Energy Recovery Ventilator (ERV) with
More informationResidential Balanced Ventilation Systems
2017 Broan and S&P Residential Balanced Ventilation Systems Residential balanced ventilation systems introduce fresh air alone, or include Heat Recovery (HRV) or Energy Recovery (ERV) features. Select
More informationResidential Fans & Air Purifiers
Residential Fans & Air Purifiers HOME VENTILATION SOLUTIONS How much airflow is reuired? The following recommendations follow minimum guidelines published by the Home Ventilating Institute (HVI): Bathroom
More informationVentilation. Axial Fans Centrifugal Fans Low Voltage Fans Shower Fans Commercial Fans Flexible Ducting Fixing Kits External Grilles Hand Dryers
Ventilation xial Fans Centrifugal Fans Low Voltage Fans Shower Fans Commercial Fans Flexible ucting Fixing Kits xternal Grilles Hand ryers Telesales Hotline 01582 544 544 9 Ventilation T extractor fans
More informationResidential Heat & Energy Recovery
Residential Heat & Energy Recovery Aeromatic Series Standard Residential HRV/ERV 95-215 CFM 2 Discover Heat & Energy Recovery A tightly built, high-performance home is a great way to conserve energy and
More informationDURAVENT POLYPRO VENTING PRODUCTS
DURVENT POLYPRO VENTING PRODUCTS INDEX FLEX VENTING SYSTEM DPTER KIT... 14-11 -VENT RETROFIT DPTERS... 14-10 CHIMNEY CP... 14-10 CHIMNEY LINING KIT... 14-10 CHIMNEY SUPPORT... 14-11 COUPLER DPTER... 14-12
More informationHRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.
HRV / ERV Heat or Energy Recovery Ventilation Systems You need fresh air, so does your home. Control Your Indoor Air Quality Following the energy crisis of the 1970s, we tended to insulate our homes and
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationMakeup Air Systems What goes out, must come in
Makeup Air Systems What goes out, must come in 2 Makeup Air Systems MUAS Makeup Air System Why do we need makeup air? In a nutshell - we would otherwise have problems. Today's homes are built to be more
More informationInstallation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier
RXID-AW90A Whole House Dehumidifier with fresh air ventilation Installation Guide Dehumidification Fresh Air Ventilation Compact Size Energy Efficient The whole house dehumidifier integrates highcapacity
More informationResidential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators
Residential and Commercial HRVs & ERVs Heat Recovery Ventilators & Energy Recovery Ventilators Residential HRVs - Horizontal Recirculating Defrost SUPERVENTOR SERIES Color coded collars easily identify
More informationGLOBAL FINISHING SOLUTIONS
GLOBAL FINISHING SOLUTIONS > Eliminate problems with drafts, stale or contaminated air, and temperature stratification > Create balanced building pressure and maintain proper comfort levels > Introduce
More informationCATALOGUE Setting a new standard for energy efficient, clean air homes.
CATALOGUE 2011-12 Setting a new standard for energy efficient, clean air homes www.lifebreath.com Manufacturer reserves the right to change specifications without notice. About Lifebreath For over 25 years
More informationINSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220
INSTALLATION GUIDE Horizontal series HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220 INSTALLATION GUIDE Peace of Mind All GeneralAire products are backed by the best limited warranty in the
More informationThe Straight Way K Sileo Series
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans The Straight Way K Series Systemair Sdn Bhd certifies that the K fans shown herein are licensed
More informationGlass Canopy Wall-Mount Hood
Glass Canopy Wall-Mount Hood FHWC3060L S 30" Stainless Steel Features Nominal Width 30" Installation Type Wall Mount Style Stainless Steel / Glass Canopy Air Discharge Vertical Air Delivery (CFM) 400 Blower
More informationMODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS
With S&P s TR & TRC (total recovery) Series for all climates, stale room air is exhausted and fresh outdoor air is brought back into the house. These two air streams are directed through a highly developed
More informationAPPUZO RANGE HOOD INSTALLATION
IMPORTANT SAFETY INFORMATION TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY, PLEASE READ THE FOLLOWING: Use the range hood only in the manner intended by the manufacturer. If you have questions,
More informationDirect Gas-Fired Make-Up Air
Direct Gas-Fired Make-Up Air Model TSU Heavy Duty, High Airflow Applications Manufacturing and Industrial Facilities Up to 64,000 cfm August 2012 Products Model TSU Direct Gas-Fired Make-Up Air Unit The
More informationAir Replacement Systems
GLOL FINISHING SOLUTIONS ir Replacement Systems > Eliminate problems with drafts, stale or contaminated air, and temperature stratification > reate balanced building pressure and maintain proper comfort
More informationUser Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.
User Manual HEAT RECOVERY VENTILATORS MODELS: 1000 HE HE 1.3 2000 HE HE 1.8 3000 HE HE 2.6 3055 COMPACT 5585 COMPACT VB0021 READ AND SAVE THESE INSTRUCTIONS. VVI, 550 Lemire Blvd., Drummondville, QC, Canada
More informationAir Replacement Systems
G L O L F I N I S H I N G S O L U T I O N S ir Replacement Systems > Eliminate problems with drafts, stale or contaminated air, and temperature stratification > reate balanced building pressure and maintain
More informationBROAN FANS AND RANGE HOODS
INDEX ATTIC VENTILATORS... 12-15 BLOWERS... 12-5 CERTIFICATION AND RATINGS... 12-2 COMMERCIAL VENTILATORS LOSONE SELECT ACCESSORIES... 12-8 CABINET 2000, 3500 CFM... 12-8 CEILING MOUNT... 12- IN-LINE...
More informationGuide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:
Date: 05/21/2001 Time: 02:57:44 PM Job Name: EarthWise VAV Terminal Units Full Spec Location: AnyTown, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SINGLE & DUAL DUCT UNIT
More informationHeat Recovery Ventilators (HRVs) Flexibility. in Perfect Form. Improving indoor air quality through better ventilation
Flex 100H Heat Recovery Ventilators (HRVs) Flexibility in Perfect Form Improving indoor air quality through better ventilation An Established Ventilation Solutions Provider Fantech For over two decades,
More informationResidential Fans & Air Purifiers
Residential Fans & Air Purifiers DUCT FANS AXC IN-LINE DUCT FANS AXC In-Line Duct Fans are designed for residential, commercial and industrial ventilation applications. The uiet and efficient backwardcurved
More informationCONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code
CONTENTS Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code 2 4 6 8 10 12 14 16 18 19 20 KITCHEN AND BATHROOM FANS The Vitro &
More informationULC S636 System. PolyPro. PolyPro Flex. Terminations
PolyPro Polypropylene venting products for high-efficiency condensing appliance installations. Chloride free, environmentally safe. Listed to ULC-S636. Specifications pplications PolyPro is a polypropylene
More informationA. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.
SECTION 15622 DIRECT GAS-FIRED BURNER & MANIFOLD SYSTEM PART 1: GENERAL 1.1 Section includes: A. Direct gas-fired heater modules B. Controls C. Equipment schedule 1.2 Related Sections A. Section 01655:
More informationSMART ERV Energy Recovery Ventilator. Build It Tight / Ventilate It Right!
SMART ERV Energy Recovery Ventilator SMART air & energy solutions SMART products include Indoor Air Quality (IAQ) and Energy efficiency products Primarily targeting the residential market Products include:
More informationVENTILATORS VH30100 COMPACT HEAT RECOVERY VENTILATOR VE30100 COMPACT ENERGY RECOVERY VENTILATOR. Installation and Operation Manual.
VENTILATORS MODELS: VH30100 30-100 CFM HRV VE30100 30-100 CFM ERV Features Three operating modes (Intermittent, Continuous and High) 100% variable speed Quick-connect duct collar system Proportional defrost
More information29" (73.7 CM) ELECTRIC DRYER INSTALLATION INSTRUCTIONS DRYER SAFETY
29" (73.7 M) LTRI RYR INSTLLTION INSTRUTIONS RYR STY...1 INSTLLTION INSTRUTIONS...1 Table of ontents...1 Tools and Parts...1 Location Requirements...2 lectrical Requirements...3 lectrical onnection...4
More informationQ U A L I T E D E P U I S
QUALITY SINCE 1967 CALIDAD DESDE 1967 Q U A L I T E D E P U I S 1 9 6 7 QUALITY SINCE 1967 CALIDAD DESDE 1967 Q U A L I T E D E P U I S 1 9 6 7 MISSION STATEMENT Innovation, Quality, Service and Reliability
More information