1 MOLS SP & SP eiling & Inline abinet xhaust Fans Making a Sound ifference with Silent Solutions eiling Inline R November 00

2 eiling and abinet xhaust Fans Great things come in small packages, as do our ceiling fans (Model SP) and cabinet fans (Model SP). e assured when you buy any Greenheck product, you are getting a quality product at a competitive price. In fact, we guarantee our ceiling and cabinet exhaust fans with a year warranty. We offer the most comprehensive ceiling and cabinet exhaust fan line in the commercial market. We are your market leader! enefits Low sound ompact size ompetitive price roadest performance selections in the industry Go Inside the Numbers Greenheck has been providing solutions for over 0 years. Preferred to over the competition Number in product quality and reliability. Number in customer satisfaction and after-sale customer service support. More than 00 times a day a new ceiling fan is put into service. year warranty. SP fans are designed for ceiling mounted applications. Greenheck certifies that the SP and SP models shown herein are licensed to bear the M seal. The ratings shown are based on tests and procedures performed in accordance with M Publication and M Publication and comply with the requirements of the M ertified Ratings Program. Models SP and SP are listed electric fans (UL/cUL 0). eiling xhaust Fans are also UL Listed for above bathtub/shower with GFI branch protected circuit. File no. 99. SP fans are designed for inline remote mounted applications. Leading dge Technical Support When you need extensive product information look no further. Greenheck products are supported by the industry s best product literature, ranging from atalogs, Installation and Operation Manuals (IOM s), lectronic Media, omputer ided Selection Program (PS) and more. ll of these can be found at ount on personal service and expertise from our national and international representative organization. To locate your nearest Greenheck representative, call () 9- or visit us at

3 Model Number ode SP - 0 FL Table of ontents Light Options: L - Fan/Light (Incandescent) ombination FL - Fan/Light (Fluorescent) ombination Nominal cfm at 0.0 inches static pressure Level of onstruction: - Premium unit; lowest sound, insulated housing - eluxe unit; low sound, low profile - Standard unit; lowest profile, inexpensive Model: SP - Silent Partner SP - abinet Silent Partner R SP SP- Light SP- Performance.... SP SP- Performance... SP SP- Light SP- Performance.... SP SP- Performance...9 SP SP- Performance.... Sound ata ccessories Specifications Quick elivery and Quick uild Programs Order from hundreds of SP and SP configurations, accessories, and thousands of other products that can ship to your job site in less than hours. We have strategically located warehouses across the United States and Internationally to fill your request at a moments notice. Speed up your process even more by ordering your units at Q Online at For other sizes and configurations where rapid response time is required, our Quick uild (Q) Program manufactures and ships your custom products in one, three, five, or ten days..

4 PRMIUM ILING FN SP The SP- is a Premium eiling Fan. It is in the top of its class when it comes to meeting sound requirements. Profile as low as 0 / inches. Sound levels as low as 0. sones. ir volume as high as,0 cfm. UL Listed for above bathtub/shower with GFI branch protected circuit. SP- FTURS 9 0 Spring Loaded luminum ackdraft amper - liminates rattling or unwanted backdrafts. Outlet - oth square and round 0 outlets are field rotatable from horizontal to vertical discharge. Power ssembly - Removes quickly for maintenance or conversion from horizontal to vertical discharge. xternal lectrical ccess - liminates removing motor pack, saving installation time. lectrical Knockouts (horizontal or vertical) - liminates drilling holes. coustic Insulation - bsorbs sound. isconnect - Servicing is quick and safe. lectrical Junction ox - Large for easy wiring. ttractive esigner Grille - oncealed attachment screws securely fasten grille to housing for quiet, rattle free operation. Mounting rackets - Fully adjustable for multiple installation conditions. Housing - mbossed galvanized steel for rigidity. Motors - ll motors are compatible for use with speed controls and have thermal overload protection. oth domestic and international applications available. 0 cycle, 0v, and 0v options. (See page for availability) 0 cycle, v, 0v, 0v, 0v, and v options. (See PS for availability) Grille Options esigner - Standard Grille ecorative - Lighted and non-lighted luminum - White enamel finish Stainless steel - Polished stainless steel finish Round uct onnection Standard -Sizes 0, 0, and 90. Round uct dapter Optional - Sizes 0 through 0 xclusive lectrical Wiring Feature Greenheck SP- models are the only fans of this type with an electrical access cover located on the housing exterior. This feature permits external wiring without removing the power assembly, saving installation time and cost. Vertical ischarge Photo shows exhaust outlet duct installed in the optional vertical position. The power assembly must be rotated to match the duct adapter position. (See SP- IOM) ouble Wide Fans vailable for applications requiring 00 cfm or greater. ouble wide fans have two double width forward curved wheels, which are housed in separate scrolls, and driven by a single motor. 9

5 PRMIUM ILING FN SP Light Options Greenheck s fan/light combination includes a prismatic or frosted lens, and compact fluorescent or incandescent lamps. Our unique patent pending light box is manufactured with a reflective material to increase the light given off by either type of lamp. UL Listed for above bathtub/showers with GFI branch protected circuit. vailable on Sizes 0 - Prismatic Lens The prismatic lens design provides approximately % more light than a traditional frosted lens. The lens may be easily removed to replace light bulbs. (Patent Pending) ompact Fluorescent Lamps (FL) Quick start bulbs Reflective light box (Patent Pending) Produce 90% less heat Lower energy costs Two watt FL bulbs equals 00 watts of incandescent light (included) Frosted Lens The frosted lens option is a traditional design which lets approximately 0% of light through the lens. The lens may be easily removed to replace light bulbs. Incandescent Lamps immable Reflective light box (Patent Pending) Low first-cost light One bulb provides up to 00 watts of light (by others) major advantage of using FL's is to save money, as shown in the table to the right. This table assumes the light is on for hours per day and that the electric rate is 0 cents per kilowatt-hour. This study was based over a. year period. eiling Radiation amper Watt 00 Watt ompact Fluorescent Incandescent ost of Lamps $.00 $0.0 Lamp Life. days (. years ) days nnual nergy ost $.9 $.90 Lamps Replaced in. years 0 0 Total ost $0.0 $0. Savings Over Lamp Life $.9 $0.00 Source: U.S. epartment of nergy, ugust 00 Office of nergy fficiency and Renewable nergy National Fire Protection ssociation (NFP) Standard 90 requires openings in fire rated ceiling/floor assemblies be protected by appropriately rated ceiling radiation dampers. s a result, many local codes require fans installed in fire rated ceilings must also be protected by dampers which are insulated against both heat and flame. The Greenheck SP- ceiling radiation damper is UL lassified, rated at three to four hours fire resistance, and is available on all SP- fans and fan/light combinations. This design saves space by allowing the damper to mount directly beneath the fan. " x SP- Fan Hanging Vibration Isolation eiling Radiation amper Grille Fire Rated eiling *R is approximately / inch larger than housing dimension. (See SP- IOM)

6 LUX ILING FN SP The SP- is a eluxe eiling Fan compact enough for almost any application. If quiet is what you are after, this fan will accommodate your needs. Profile as low as / inches. Sound levels as low as. sones. ir volume as high as 9 cfm. UL Listed for above bathtub/shower with GFI branch protected circuit. SP- FTURS 9 0 luminum ackdraft amper - Prevents unwanted backdrafts. Round Standard Outlet ( or in.) - Versatile for quick, easy connections. Power ssembly - Removes quickly for maintenance. lectrical ccess (vertical) - liminates drilling holes. isconnect - Servicing is quick and safe. lectrical Junction ox - Large for easy wiring. ttractive esigner Grille - oncealed attachment screws securely fasten grille to housing for quiet, rattle free operation. Mounting rackets - Fully adjustable for multiple installation types. Housing - mbossed galvanized steel for rigidity and low profile for height restricted areas. Motors - ll motors are compatible for use with speed controls and have thermal overload protection. oth domestic and international applications available. 0 cycle, 0v, and 0v options. (See page for availability) 0 cycle, v, 0v, 0v, 0v, and v options. (See PS for availability) 9 Grille Options esigner - Standard Grille ecorative - Lighted and non-lighted luminum - White enamel finish Stainless steel - Polished stainless steel finish Round uct onnection in. - 0, 0, and 0 in. - 90, 0, 0, and 00 0 ontractor Paks Save installation time and labor by installing the housing first, then installing the internal components after the sheetrocking, plastering, and finishing is done. Housings are packaged in one box, power assembly and grille are packaged in another box. omponents are shipped to coincide with the phase of your project.

7 LUX ILING FN SP Light Options Greenheck s new fan/light combination includes a prismatic or frosted lens, and compact fluorescent or incandescent lamps. Our unique patent pending light box is manufactured with a reflective material to increase the light given off by either lamp. UL Listed for above bathtub/showers with GFI branch protected circuit. vailable on Sizes 0-0 Prismatic Lens The prismatic lens design provides approximately % more light than a traditional frosted lens. The lens may be easily removed to replace light bulbs. (Patent Pending) ompact Fluorescent Lamps (FL) Quick start bulbs Reflective light box (Patent Pending) Produce 90% less heat Lower energy costs Two watt FL bulbs equals 00 watts of incandescent light (included) Frosted Lens Incandescent Lamps The frosted lens option is a traditional design which lets approximately 0% of light through the lens. The lens may be easily removed to replace light bulbs. immable Reflective light box (Patent Pending) Low first-cost light One bulb provides up to 00 watts of light (by others) major advantage of using FL's is to save money, as shown in the table to the right. This table assumes the light is on for hours per day and that the electric rate is 0 cents per kilowatt-hour. This study was based over a. year period. eiling Radiation amper Watt 00 Watt ompact Fluorescent Incandescent ost of Lamps $.00 $0.0 Lamp Life. days (. years ) days nnual nergy ost $.9 $.90 Lamps Replaced in. years 0 0 Total ost $0.0 $0. Savings Over Lamp Life $.9 $0.00 Source: U.S. epartment of nergy, ugust 00 Office of nergy fficiency and Renewable nergy National Fire Protection ssociation (NFP) Standard 90 requires openings in fire rated ceiling/floor assemblies be protected by appropriately rated ceiling radiation dampers. s a result, many local codes require fans installed in fire rated ceilings must also be protected by dampers which are insulated against both heat and flame. The Greenheck SP- ceiling radiation damper is UL lassified, rated at three to four hours fire resistance, and is available on all SP- fans and fan/light combinations. This design saves space by allowing the damper to mount directly beneath the fan. " x SP- Fan Hanging Vibration Isolation eiling Radiation amper Grille Fire Rated eiling *R is approximately / inch larger than housing dimension. (See SP- IOM)

8 STNR ILING FN SP The SP- is our economy ceiling fan designed for light commercial applications. Profile as low as / inches. Sound levels as low as.9 sones. ir volume as high as cfm. UL Listed for above bathtub/shower with GFI branch protected circuit. SP- FTURS Plastic ackdraft amper - Prevents unwanted backdrafts. Round Outlet - inch diameter allows quick easy connections. Power ssembly - Removes quickly for maintenance. isconnect - Servicing is quick and safe. Polymeric Grille - Quickly snaps into place. Mounting rackets - djustable for several installation types. Housing - Galvanized steel for rigidity and low profile for height restricted areas. Motors - ompatible for use with speed controls and has thermal overload protection. 0 cycle, v

9 Things to know, when sound is critical SOUN T The sound data shown in this catalog has been presented to aid the system designer in selecting a fan which will meet the desired sound criteria. Sone levels have been included on the performance pages to provide a means of quickly evaluating the relative loudness of a fan selection. What is a sone? Sones are an internationally recognized unit of loudness. In practical terms, the loudness of one sone is equivalent to the sound of a quiet refrigerator measured from five feet away in an acoustically average room. sone is a single number rating, which indicates the inlet noise derived from the eight audible octave bands. Sones are a linear measurement of sound level. For example, a sound level of 0 sones is twice as loud as sones. What is the difference in a M Sone vs. HVI Sones? In general, the M (ir Movement and ontrol ssociation) sone value is focused on commercial markets, whereas the HVI (Home Ventilating Institute) sone value is focused on residential markets. oth calculate their sone data from the same raw test data (eight octave bands), however an M sone applies a hemispherical correction factor to the sound power and rounds to the nearest 0., whereas HVI applies a spherical correction factor to the sound power and rounds to the nearest 0. under. sones and to the nearest 0.,. sones and greater. There are no conversions from one sone to the other, each must be calculated. In every instance the same fan will have a lower HVI calculated sone rating than an M calculated sone rating. an radiated noise increase the sound levels? Radiated noise from fan housings can cause unacceptable sound levels, on any brand of fan. The size of these fans allows them to be placed in areas where this noise will be transmitted to the conditioned space through walls or ceilings. Where possible, cabinet fans should be located in remote parts of the ventilation system. When should a SP or SP fan be used? Model SP and SP fans are designed for the lowest possible sound levels. Forward curved wheels, insulated housings, and vibration isolators between the motor and housing contribute to quiet, efficient operation. pplied and installed as recommended, SP and SP sound levels will fall well within the ranges shown in the chart above. For applications where sound levels are critical, a remote mounted SP with ductboard is recommended. Placement of SP/SP fans should take into account the desired sound level at the location of the listener. Their compact size allows the system designer greater flexibility in locating these fans for lowest sound levels. In critical sound areas, insulated ductwork, flexible duct connections, or placing the fan in a remote section of the ductwork (away from the critical area) offers the best means of meeting desired sound levels. When room sound levels are critical, such as in executive offices, conference rooms, hospital operating rooms, and school study areas, a SP fan is the best choice. Shown here is a comparison of SP and SP fans of the same size, with equal performance in typical installations. The SP shows lower sone values. Fiberglass ductboard SUGGST LIMITS FOR ROOM LOUNSS Sones.- - Private homes (rural and suburban).- - onference rooms - - Hotel rooms, libraries, movie theatres, executive offices.- - Schools and classrooms, hospital wards and operating rooms -9-0 ourt rooms, museums, apartment houses, private homes (urban) - - Restaurants, lobbies, general open offices, banks - - orridors and halls, cocktail lounges, washrooms and toilets - - Hotel kitchens and laundries, supermarkets Reprinted from M Publication 0 (pplication of Sone Ratings for Non ucted ir Moving evices with Room-Sone-d correlations). with the written permission from the M International Inc. 0 West University rive, rlington Heights, IL NOT: Values above are for room loudness and are not sound ratings. Room loudness is the resulting level in a conditioned space after the acoustical qualities of the room have been accounted for. Remote mounted Model SP with vibration isolators and insulated ductwork provides quietest installation. Model FM WG FRPM Sones SP-0 0 / 000. SP-0 / 000.* *Sone value with insulated inlet duct. Model SP mounted directly overhead may be too loud for sound critical applications. 9

10 PRMIUM INLIN FN SP The SP- is a Premium Inline Fan. It outperforms the competition and is preferred by specifying engineers. Profile as low as 0 / inches. Sound levels as low as 0. sones. ir volume as high as, cfm. UL/cUL Listed. SP- FTURS Spring Loaded luminum ackdraft amper - liminates rattling or unwanted backdrafts. Outlet - oth square and round outlets are field rotatable from horizontal to vertical discharge. Power ssembly - Removes quickly for maintenance or conversion from horizontal to vertical discharge. xternal lectrical ccess - liminates removing motor pack, saving installation time. lectrical Knockouts (horizontal or vertical) - liminates drilling holes. coustic Insulation - bsorbs sound. isconnect - Servicing is quick and safe. lectrical Junction ox - Large for easy wiring. ccess Panel - Gain easy access to internal components once installed. Mounting rackets - Fully adjustable for multiple installation conditions. Housing - mbossed galvanized steel for rigidity. Motors - ll motors are compatible for use with speed controls and have thermal overload protection. oth domestic and international applications available (not shown). 0 cycle, 0v, and 0v options. (See page for availability) 0 cycle, v, 0v, 0v, 0v, and v options. (See PS for availability) 0 xclusive lectrical Wiring W Feature Greenheck SP- models are the only fans of this type with an electrical access cover located on the housing exterior. This feature permits external wiring without removing the power assembly, saving installation time and cost. Vertical ischarge Photo shows exhaust outlet duct installed in the optional vertical position. The power assembly must be rotated to match the duct adapter position. (See SP- IOM) ouble Wide W Fans vailable for applications requiring 00 cfm or greater. ouble wide fans have two double width forward curved wheels, which are housed in separate scrolls, and driven by a single motor. 9

11 LUX INLIN FN SP The SP- is a compact eluxe Inline Fan. It is designed to fit in small remote quarters. Profiles as low as / inches. Sound levels as low as.0 sones. ir volume as high as cfm. UL/cUL Listed. SP- FTURS luminum ackdraft amper - Prevents unwanted backdrafts. Round Standard Outlet ( or in.) - Versatile for quick, easy connections. Power ssembly - Removes quickly for maintenance. 0 9 lectrical ccess (vertical) - liminates drilling holes. isconnect - Servicing is quick and safe. lectrical Junction ox - Large for easy wiring. ccess Panel - Gain easy access to internal components once installed. Mounting rackets - Fully adjustable for multiple installation types. 9 Housing - mbossed galvanized steel for rigidity and low profile for height restricted areas. 0 Motors - ll motors are compatible for use with speed controls and have thermal overload protection. oth domestic and international applications available. 0 cycle, 0v and 0v options. (See page 9 availability) 0 cycle, v, 0v, 0v, 0v, and v options. (See PS for availability)

12 ccessories Speed ontrols Speed controls may be used on Model SP and SP fans for manual adjustment of the fan s performance (for final system balancing) or to control the fan s output in confined spaces, such as conference or meeting rooms. The fan can be adjusted to 0% of design airflow with a speed control. This reduction in airflow and fan speed is also accompanied by a reduction in noise level. Solid state speed controls are available for a range of applications up to amps. Speed controls can be used to operate more than one fan if the combined total amperage of the fans does not exceed the control rating. Model WSS - For use w/ shaded pole and PS motors. vailable shipped loose or mounted internal or external Rated for - V, mp UL Listed Require a x handy box Model W0 - For use w/ shaded pole and PS motors. vailable shipped loose or mounted internal or external Rated for 0-0V, mp UL Listed Requires x handy box Model W - For use w/ shaded pole and PS motors. vailable shipped loose or mounted internal or external Rated for V, mp UL Listed Requires x handy box Model WSS - For use w/ shaded pole and PS motors. vailable shipped loose or mounted internal or external Rated for 0-0V, mp UL Listed Requires x handy box Model 0WSS - For use w/ shaded pole and PS motors. vailable shipped loose or mounted internal or external Rated for - V, 0 mp UL Listed Requires x handy box Model WSS - For use w/ shaded pole and PS motors. vailable shipped loose or mounted internal or external Rated for - V, mp UL Listed Requires x handy box Switches H N LO 0 V FULL VOLTG LK XTRNL JUMPR SP ONTROL Switches may be used on Models SP and SP fans to enable manual control of your fan or fan/light combination. There are several options to fit your application. NM - Single pole rocker switch assembly. Rated for, V, mp, / Hp UL Listed Model MS-- Single pole rocker switch assembly with cover and pilot light. Rated for, V, mp, / Hp UL Listed NM - Two pole rocker switch assembly. Rated for, 0/0/0/V, 0 mp, Hp UL Listed Requires a x handy box. Time elay Switch R WHIT VRIL VOLTG SWITH FULL VOLTG otted line indicates for use with 0W switch only. Time delay switches save energy by automatically turning off equipment. They may be used with Models SP and SP fans and fan/light combinations, for extended operating time of fan. Time delay switches act in the same manner as a standard switch, however, there is a delay of to 0 minutes after the it has been turned off. FN UX VI LO Model GT - Single switch controls both fan and light. vailable shipped loose. VOLT 0 YL (HOT) LK LU (00 Watt Max) LIGHT Silent Operation UL Listed Rated for V Requires x handy box (NUTRL) WHIT R (. mps Max) FN MOTOR

13 ccessories Motion etectors Motion detectors may be used with Models SP and SP fans, or fan and light combinations. Motion detectors use a passive infrared motion detector that will automatically turn on the fan when a change in temperature is sensed. They have a viewing area of 0 degrees, however they must be placed in the line-of-sight. They also have an adjustable time delay shutoff setting of to 0 minutes. Grille Motion etectors are available on models up thrugh size SP-90 and SP-00. Rated for V UL Listed Model MW For use on fan or lights. vailable shipped loose. Rated for V UL Listed Requires x handy box Transformers Model T-.0 - UL Listed Rated for 0/ to, mps Model T-. - UL Listed Rated for 0/ to,. mps Model T-. - UL Listed Rated for 0/ to,. mps Model T-. - UL Listed Rated for 0/ to,. mps lack Green Gnd. Red Load (. mps Max.) Wall Mount Transformers are available for applications requiring voltage reduction. Selection is based on motor amperage. ll transformers are shipped loose. LK H H H V TO V TRNS. 0 V X R LK Hot Neutral X R LK Motion Sensor Fan Motor and/or Light Grille Mount SWITH OX SWITH lack White Red lack Green White Hot Neutral Ground V SUPPLY V MOTOR eiling Radiation amper Filters The Greenheck SP- and SP- ceiling radiation dampers are UL lassified, rated at three to four hours fire resistance, and is available on all SP- and SP- fans and fan/light combinations. This design saves space by allowing the damper to mount directly beneath the fan. Fans used in most applications, even where air is not excessively dirty, will collect airborne dirt on wheels and motors over time. ccumulations of dirt on the fan wheel will sharply reduce performance and cause imbalance. irt buildup on the motor can cause it to overheat. ll of these conditions will shorten the life of the fan. To help reduce this accumulation, washable aluminum mesh filters are available to trap FILTR LOSS HRT dirt before it enters the fan. These filters should be regularly cleaned to maintain. performance. Fig. (Filter Loss hart) shows the effect the filter will have on. performance. To determine the added resistance, divide the desired cfm by the filter area (ft.0 ). This will give FPM. Use this with the filter loss chart to get the added resistance. In addition to reducing dirt accumulations on the motor and. wheel, filters also reduce sound levels.. IMNSIONL T. SP Model Filter Model Filter esigner lum. rea Grille Grille (ft) SP-0-90 F-00 F-0.0 SP-0-00, F-00 F-0. SP-0-0 SP-0-0 N F-0.9 SP N F-0.9 Mesh Filter SP Grille SP Model R Length Width Height *dd an L to all R models if fan & light combo is used. Resistance in w.c Velocity FPM x 00 Fig.

14 Wall ischarge ccessories G F MOL W (Round onnection) Hooded Wall ap luminum construction - aluminum finish For outside wall applications uilt in birdscreen (not available on W-) and damper For use Model with sizes W- 0, 0-0 / / W / W /. MOL W (Square/Rectangular onnections) Hooded Wall ap Steel construction with black enamel finish For outside wall applications uilt in birdscreen and damper For use Model with sizes F G W-0x 0-90 / / / 0 / / / W-x / 0 / / / / / W-x / 0 / / / / / MOL WL Wall Louvered ischarge nodized aluminum grille uilt in damper Not recommended for exterior applications exposed to severe weather conditions. n external wall louver is recommended for such applications. For use Model with sizes WL-0x 0-90 / 0 / / WL-x / 9 MOL R Round uct onnector Replaces the standard square discharge ductconnector and damper. Uses existing mounting holes Galvanized steel construction R does not include a damper MOL TR X Transition uct Reducer Reduces duct from to inches. Galvanized steel construction For use with sizes Model 0-00 TR x * * Used in conjunction with R-. ia. For use with sizes Model ia. R R in. dia.. in. in. dia FM x MOL V rick Vent esigned for installation in masonry walls nodized aluminum construction uilt in aluminum mesh insect screen 0 9 For use Model with sizes V / / V 90-0 / V / / SSORY PRSSUR ROPS The chart below can be used with all of the discharge accessories shown on these two pages. Specific pressure drop values for these accessories must be included in total system calculations for proper fan selection Pressure rop in Inches of Water Gauge bove accessories tested with feet of inlet duct WL-x RJ-0x0 V- W-x V- W-x W- W-0x W- RJ-x9 L-0x WL-0x V-0 RF- R-

15 oof ischarge ccessories / / 9 / 0 MOL RJ Pitched Roof ap Steel construction with black enamel finish Integral flashing flange uilt in birdscreen and damper Model For use with sizes Throat RJ- 0, / / / / in. ia. RJ-x / / / 0 / / x9 RJ-0x / / / / 9 / 0x0 UR P Flat Roof aps / MOL L - 0x lbow ischarge with Grille esigned for installation under roof eaves Painted steel grille uilt in damper For SP/SP sizes 0-90 / FLSHING FLNG ia. ia. / ia. / in. ia. MOL R- Weathertight aluminum construction Integral birdscreen uilt in curb cap Requires roof curb MOL GRS ll aluminum exterior construction Galvanized steel internal supports Integral birdscreen uilt in curb cap Requires roof curb MOL RF- Weathertight aluminum construction Integral birdscreen uilt in flashing flange MOL GRSF ll aluminum exterior construction Galvanized steel internal supports Integral birdscreen uilt in flashing flange Model For use with sizes Throat ia. R / GRS / / 0 / GRS / / / / GRS- 0-0 / / / / GRS / / 0 / Model For use with sizes Throat ia. RF / GRSF / / 0 / GRSF / / / / GRSF / / / / GRSF / / 0 / HNGING VIRTION ISOLTORS Vibration isolator kits are available for suspended installations. Kits include all hardware necessary to mount one unit, with the exception of 0- threaded rod to be supplied by others. Fan mounting brackets include prepunched mounting holes for ease of installation. 0- hanging support rod by others Unit Size 0-00 / / 0-90 / / / / 0, 0 0, 0 9 / 9 / 00 / / / / 0, 0 9 / / 00 9 / /

16 PRMIUM ILING FN SP IMNSIONL T Model Outlet connection width is inch - Mounting bracket width is / inch For complete dimensional information, see PS submittal drawings. ll dimensions are in inches. Std. ecorative Unit Grille Grille WT. 0, 0, 90 / 0 / / I. / x / / sq. 0,, 90 / 0 / 0 / / x / / sq. 00, 0, 90, 90 / / / x / / sq. 0, 0 / / 9 / x / - 00 / / / 9 / / x / - 0, 0 / / 0 9 / x / - 900, 00, 0, 0 / / / / x / - PRFORMN T HVI FM/Static Pressure in inches of WG Model RPM mps Watts Sones ,, FM 0 SP Sones ,, FM 0 SP Sones....,, FM 99 SP Sones.....9,,,, FM SP Sones....,,, FM 0 SP Sones....9,,, FM 9 9 SP Sones...9.., FM SP Sones , FM 0 9 SP Sones ,, FM 9 0 SP Sones ,, FM SP Sones FM 0 0 SP Sones....., FM SP Sones FM SP Sones FM 0 0 SP Sones , FM 0 SP Sones FM SP Sones......, FM SP Sones FM 0 0 SP Sones , FM SP Sones HVI sones at 0. wg vailable with light Performance shown is for Model SP exhaust for installation type : Free inlet, ucted outlet. Performance ratings include the effects of an inlet grille and backdraft damper in the airstream. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at ft. (.m) in a hemispherical free field calculated per M Standard 0. Values are for installation type : free inlet fan sone levels. vailable with R - eiling Radiation amper vailable with 0 Hz motors (See PS for performance) UL Listed for use above tubs. vailable with volt motor.

17 LUX ILING FN IMNSIONL T SP Model * esigner ecorative Unit Grille Grille WT. 0, 0, & 0 / / / / / x / / sq. 9 90, 0, 0, 00 / / / / / x / / sq. 0 * dd. inches to dimension for incandescent light Mounting bracket width is / inch For complete dimensional information, see PS submittal drawings. ll dimensions are in inches. PRFORMN T Model RPM MPS HVI FM/Static Pressure in inches of WG Watts Sones SP FM 0 9 Sones SP FM Sones SP FM 0 0 Sones SP FM Sones SP FM Sones SP FM Sones SP FM Sones ,,,,,,,,,,,,,,,,,,,, HVI sones at 0. wg vailable with light vailable with R - eiling Radiation amper vailable with 0 Hz motors (See PS for performance) UL Listed for use above tubs. vailable with volt motor. Performance shown is for Model SP exhaust for installation type : Free inlet, ucted outlet. Performance ratings include the effects of an inlet grille and backdraft damper in the airstream. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at ft. (.m) in a hemispherical free field calculated per M Standard 0. Values are for installation type : free inlet fan sone levels. R STNR ILING FN SP IMNSIONL T Model F Grille Weight 0 / / / / / 9 / x 9 For complete dimensional information, see PS submittal drawings. ll dimensions are in inches. F PRFORMN T FM/static Pressure in inches of WG Model RPM MPS Watts FM 9 9 SP Sones Performance shown is for Model SP exhaust for installation type : Free inlet, ucted outlet. Performance ratings include the effects of an inlet grille and backdraft damper in the airstream. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at ft. (.m) in a hemispherical free field calculated per M Standard 0. Values are for installation type : free inlet fan sone levels.

18 PRMIUM INLIN FN SP IMNSIONL T Model F G WT. 0,, 90 / 0 / 0 / 9 / 00,0, 90, 90 / / / 0 0, 0 / / / / 00 / / / 9 / / 0 / 0, 0 / / 0 / / 900, 00, 0, 0 / / / / / / 9 0, 0 / / / 00 / / / 0 / / F F Inlet G Inlet and outlet connections widths are inch - Mounting bracket width is / inch For complete dimensional information, see PS submittal drawings. ll dimensions are in inches. G PRFORMN T Model RPM MPS Watts, SP SP , SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP Units available with 0 Hz motors (See PS for performance) FM/Static Pressure in inches of WG FM 0 0 Sones..... FM 9 Sones..... FM Sones FM Sones FM 0 Sones FM Sones FM Sones FM 0 Sones FM 0 0 Sones FM 9 0 Sones FM 9 Sones FM 0 0 Sones FM 90 0 Sones FM Sones FM Sones FM 0 0 Sones FM Sones FM Sones FM Sones vailable with volt motor. Performance shown is for Model SP inline for installation type : Insulated ucted inlet, ucted outlet. Performance ratings include the effects of a backdraft damper in the airstream. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at ft. (.m) from the test inlet duct in a hemispherical free field calculated per M Standard 0. Values are for installation type : ucted inlet fan sone levels. Ratings do not include the effects of duct end correction.

19 LUX INLIN FN SP IMNSIONL T Model F G WT. 0, 0, 00 / / / / 0 / / 0 / Outlet connection width is inch - Mounting bracket width is / inch For complete dimensional information, see PS submittal drawings. ll dimensions are in inches. PRFORMN T Inlet FxG dia., Model RPM MPS Watts SP , SP , SP Units available with 0 Hz motors (See PS for performance) Performance shown is for Model SP inline for installation type : Insulated ucted inlet, ucted outlet. Performance ratings include the effects of a backdraft damper in the airstream. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at ft. (.m) from the test inlet duct in a hemispherical free field calculated per M Standard 0. Values are for installation type : ucted inlet fan sone levels. Ratings do not include the effects of duct end correction. MOL SP-0 eiling mounted exhaust fans shall be of the centrifugal direct drive type. The fan housing shall be constructed of steel. The plastic duct collar shall be a tapered sleeve for ease of connection to and in. round ductwork and shall include a backdraft damper. The grille shall be constructed of non-yellowing high impact polystyrene and attached to the housing with torsion springs. The wheels shall be constructed of high strength polymer. The access for wiring shall be external. The motor disconnect shall be internal and of the plug in type. ll fans shall bear the M ertified Ratings Seal for sound and air performance. Model SP-0 shall be UL listed. Fans shall be Model SP-0 as supplied by Greenheck, Schofield, Wisconsin. MOLS SP-0, 0, 0, 90, 0, 0, and 00 eiling mounted exhaust fans shall be of the centrifugal direct drive type. The fan housing shall be constructed of steel. The steel duct collar shall be in. in diameter on the 0, 0, and 0 and in. in diameter on the 90, 0, and 00 to accept in. and in. round ductwork and shall include a backdraft damper. The designer grille shall be constructed of non-yellowing high impact polystyrene and attached to the housing with hidden attachment screws. The access for wiring shall be external. The motor disconnect shall be internal and of the plug in type. The motor shall mounted on vibration isolators. The fan wheel shall be of the forward curved centrifugal type, constructed of calcium carbonate filled polypropylene and dynamically balanced. ll fans shall bear the M ertified Ratings Seal for sound and air performance and shall be UL/cUL Listed. eiling or wall mount fans shall be Model SP-0, 0, 0, 90, 0, 0 or 00 as manufactured by Greenheck, Schofield, Wisconsin. MOLS SP-0 thru 0 eiling mounted exhaust fans shall be of the centrifugal direct drive type. The fan housing shall be constructed of heavy gauge galvanized steel. The housing interior shall be lined with / in. acoustical insulation. The outlet duct collar shall include an aluminum backdraft damper on all SP- sizes and shall be spring loaded on size SP-0 and larger. Outlet shall be adaptable for horizontal or vertical discharge. The designer grille for sizes SP-0 through SP-90 shall be constructed of high impact polystyrene and for sizes SP-0 through SP-0, the grille shall be constructed of aluminum. Grilles shall be non-yellowing. FM/Static Pressure in inches of WG FM Sones FM 9 9 Sones FM 0 9 Sones vailable with volt motor. TYPIL SPIFITIONS The access for wiring shall be external. The motor disconnect shall be internal and of the plug in type. The motor shall be mounted on vibration isolators. The fan wheel(s) shall be of the forward curved centrifugal type and dynamically balanced. ll fans shall bear the M ertified Ratings Seal for sound and air performance and shall be UL/cUL Listed. eiling or wall mount fans shall be Model SP as manufactured by Greenheck, Schofield, Wisconsin. MOLS SP-0, 0, and 00 uct mounted exhaust, supply or return air fans shall be of the centrifugal direct drive type. The fan housing shall be constructed of steel. The steel duct collar shall be in. in diameter to accept in. round ductwork and shall include a backdraft damper. The access for wiring shall be external. The motor disconnect shall be internal and of the plug in type. The motor shall mounted on vibration isolators. The fan Wheel shall be of the forward curved centrifugal type, constructed of calcium carbonate filled polypropylene and dynamically balanced. ll fans shall bear the M ertified Ratings Seal for sound and air performance and shall be UL/cUL Listed. eiling or wall mount fans shall be Model SP-0, 0 or 00 as manufactured by Greenheck, Schofield, Wisconsin. MOLS SP-0 thru 00 uct mounted exhaust, supply or return air fans shall be of the centrifugal direct drive type. The fan housing shall be constructed of heavy gauge galvanized steel. The housing interior shall be lined with / in. acoustical insulation. The outlet duct collar shall include an aluminum backdraft damper and shall be adaptable for horizontal or vertical discharge. The access for wiring shall be external. The motor disconnect shall be internal and of the plug in type. The motor shall be mounted on vibration isolators. The fan wheel(s) shall be of the forward curved centrifugal type and dynamically balanced. ll fans shall bear the M ertified Ratings Seal for sound and air performance and shall be UL/cUL Listed. eiling or wall mount fans shall be Model SP as manufactured by Greenheck, Schofield, Wisconsin. 9

20 eiling Fan Solutions... eiling Fans eiling Fans w/ Light eiling Fans w/ R eiling Fans w/ Light & R SP-0 SP-0 SP-90 SP- SP-0 SP-0 SP-90 SP-90 SP-0 SP-90 SP-00 SP-0 SP/SP LIMIT WRRNTY Greenheck Fan orporation warrants its SP/SP products to be free of any defect in material or workmanship for a period of three () years from the date of purchase. In the event of such a defect during the warranty period, Greenheck Fan orporation agrees, at its option, to either repair or replace the defective product free of charge. This warranty runs to the original purchaser of such SP/SP products for a period of three () years from the date of purchase. ny product repaired or replaced under this warranty will, itself, be warranted only for the remainder of the warranty period of the original product being repaired or replaced. ll light bulbs are excluded under this limited warranty. Greenheck Fan orporation is not responsible for any removal, installation, or transportation cost. For full SP/SP warranty information visit ue to continuing research, Greenheck reserves the right to change specifications without notice. R Number one in air movement and control. entrifugal and Vane xial Fans Fans and Ventilators nergy Recovery Ventilators & Make-Up ir Units Kitchen Ventilation Systems ampers and Louvers Visit the Greenheck website for the most current information available Greenheck P.O. ox 0 Schofield, WI -00 Phone ()9- Fax ()-99 opyright 00 Greenheck Fan orp. SP SP SP Rev November 00

5 year fan housing and motor warranty

5 year fan housing and motor warranty MODEL SWF SIDEWALL CENTRIFUGAL FAN MODEL FEATURES Exhaust air up to 416 CFM with static pressure capabilities to 1.5 w.g. Galvanized steel casing with black backed enamel coating Pre-wired junction box

More information

Utility and Centrifugal

Utility and Centrifugal Utility and entrifugal Utility and entrifugal reenheck s tiered centrifugal product offering reenheck s tiered model approach gives you flexibility in size, performance and construction, matching the appropriate

More information

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty MODEL OVERVIEW The POWERVENT (PV) series of direct drive centrifugal in-line duct ventilation fans consists of twelve model sizes 4, 5, 6, 8, 10 and 12.4 respectively. All models are designed for direct

More information

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation Industrial Space Heating Direct Gas-Fired Heating Greenheat 00% Outdoor Air Greenheat 50/50 Recirculation 80/0 Recirculation March 008 Product Overview Industrial Space Heating Greenheck s space heating

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

Indirect Gas-Fired Make-Up Air

Indirect Gas-Fired Make-Up Air Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up

More information

Direct Gas-Fired Make-Up Air

Direct Gas-Fired Make-Up Air Direct Gas-Fired Make-Up Air Model TSU Heavy Duty, High Airflow Applications Manufacturing and Industrial Facilities Up to 64,000 cfm August 2012 Products Model TSU Direct Gas-Fired Make-Up Air Unit The

More information

August 2004 AB0804. Accessories Book. Fantech I Your Ventilation Solutions Company

August 2004 AB0804. Accessories Book. Fantech I Your Ventilation Solutions Company ugust 200 00 ccessories ook Fantech I Your Ventilation Solutions ompany Supply/xhaust Fans ombination xhaust Grill and Light VL Vent light combination. Smallscale grill with 0 watt halogen light (MR1 bulb

More information

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A Operating Instructions & Parts Manual EN Silent Low-Profile Ceiling Fans Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A 465933 PLEASE READ AND SAVE THESE INSTRUCTIONS. READ CAREFULLY BEFORE

More information

ZEPHYR Ceiling Exhaust Fans

ZEPHYR Ceiling Exhaust Fans ZEPHYR Ceiling Exhaust Fans PRODUCT GUIDE PennBarry Your Single Source for Commercial & Industrial Supply & Exhaust Fans www.pennbarry.com TABLE OF CONTENTS INTRODUCTION 3-6 CERTIFICATIONS & LISTINGS 7

More information

ZEPHYR Ceiling Exhaust Fans

ZEPHYR Ceiling Exhaust Fans ZEPHYR Ceiling Exhaust Fans PRODUCT GUIDE PennBarry Your Single Source for Commercial & Industrial Supply & Exhaust Fans www.pennbarry.com TABLE OF CONTENTS INTRODUCTION 3-6 CERTIFICATIONS & LISTINGS 7

More information

Energy Efficiency (CFM/Watts)* Watts PC /31 0.1/ / / / /63 <0.3

Energy Efficiency (CFM/Watts)* Watts PC /31 0.1/ / / / /63 <0.3 R MODEL PC Features & Construction Extremely quiet operation

More information

Insulated Ventilators. Operating Instructions & Parts Manual

Insulated Ventilators. Operating Instructions & Parts Manual Operating Instructions & Parts Manual EN Insulated Ventilators Models 3DPE4B, 3DPE5B, 3DPE6A, 5AE70B, 5AE71B, 5AE72A, 5AE73 thru 5AE81, 6WZN1, 6WZN2, 36WG64 and 36WG65 465932 PLEASE READ AND SAVE THESE

More information

March 2003 AB0303. Accessories Book. Fantech I Your Ventilation Solutions Company

March 2003 AB0303. Accessories Book. Fantech I Your Ventilation Solutions Company March 200 00 ccessories ook Fantech I Your Ventilation Solutions ompany Supply/xhaust Fans ombination xhaust Grill and Light VL Vent light combination. Smallscale grill with 0 watt halogen light (MR1 bulb

More information

Featuring Vent Lights and Premium Grilles

Featuring Vent Lights and Premium Grilles Featuring Vent Lights and Premium Grilles The World s Leading Producer of Air Movement Products November 2013 Premium Choice Bathroom Fans For YOUR Family & YOUR Home Today s homes are built to be tighter

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating

More information

SECTION (15833) - HVAC POWER VENTILATORS

SECTION (15833) - HVAC POWER VENTILATORS PART 1 GENERAL 1.01 SUMMARY SECTION 23 34 23 (15833) - HVAC POWER VENTILATORS A. Section Includes: 1. Centrifugal Roof Ventilators. 2. Up-blast Roof Exhaust Fans (Kitchen Hood Exhaust). 3. Ceiling-Mounted

More information

for MODEL KSU MAKE-UP AIR UNITS

for MODEL KSU MAKE-UP AIR UNITS Part # 457615 Installation, Operation and Maintenance Instructions for MODEL KSU MKE-UP IR UNITS Installation...2-6 -w/fan Pack Extension...2-3 -Down last Discharge...4-5 -Horizontal Discharge...6 Electrical

More information

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You. TGIF- Indirect Fired Heating Systems Technical Guide for: IF Indoor Installations IFW Outdoor Installations Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide In the business of

More information

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified

More information

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

A. General: Refer to paragraph entitled SUBMITTAL in Section Include the following data: SECTION 15860 - FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR MECHANICAL

More information

Plenum Fans. Model HPA. Direct Drive

Plenum Fans. Model HPA. Direct Drive Plenum Fans Model HPA Direct Drive October 2012 Quiet & Efficient HPA Plenum Fans Greenheck s modular plenum fan, model HPA, is designed and engineered to provide superior performance and reliability in

More information

KIC Air Curtains. Technical Guide

KIC Air Curtains. Technical Guide TGKIC-3 KIC Air Curtains Technical Guide AIR PERFORMANCE AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. King certifies that the air curtains shown herein are licensed to bear the AMCA seal. The

More information

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

Outside Air Requirements... SOLVED!

Outside Air Requirements... SOLVED! Outside Air Requirements... SOLVED! Advancing VentilationTM refresh-0918 September 2018 The Whole Building Ventilation Standard With houses and buildings being built as tightly as possible, we are plagued

More information

Make-Up Air Systems. Performance. Model DGK, DG, DGX

Make-Up Air Systems. Performance. Model DGK, DG, DGX DGK, DG, DGX 96 Make-Up ir Systems Direct Fired Gas Heat DGK-15-25 DG-10-20 -30 DGX-12-22 -32 *DGX with PDX-12-22 -32 est vailable Program 5 Days 10 Days 15 Days * est vailable based on size and capacity

More information

Air in Motion. Fan Guide Book. January 2001 FB-0101

Air in Motion. Fan Guide Book. January 2001 FB-0101 Air in Motion Fan Guide Book January 2001 FB-0101 Find the Fan that Fits Page by page, product by product, this Fantech Guide Book offers you ventilation solutions to meet a wide variety of residential

More information

Residential Balanced Ventilation Systems

Residential Balanced Ventilation Systems 2017 Broan and S&P Residential Balanced Ventilation Systems Residential balanced ventilation systems introduce fresh air alone, or include Heat Recovery (HRV) or Energy Recovery (ERV) features. Select

More information

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code CONTENTS Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code 2 4 6 8 10 12 14 16 18 19 20 KITCHEN AND BATHROOM FANS The Vitro &

More information

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

Bathroom Ventilation

Bathroom Ventilation Bathroom Ventilation featuring Also with TD-MIXVENT and PV-POWERVENT Bathroom Exhaust Kits August 2015 1 The Fan of your CHOICE To protect the two most valuable investments of your life, your home and

More information

Description. Construction

Description. Construction LUH LUH PDS Horizontal Unit Heater 2.6 to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT SECTION 15300 - HVAC - MAJOR EQUIPMENT PART 1 - GENERAL 1.1 MECHANICAL GENERAL A. Section 15010 is applicable. PART 2 - PRODUCTS 2.1 FANS A. General: 1. All fans shall bear the AMCA Certified Performance

More information

KUH. Horizontal Unit Heater. Applications. Description

KUH. Horizontal Unit Heater. Applications. Description KUH KUH PDS Horizontal Unit Heater 2.6 kw to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

Gas-Fired Unit Heaters Commercial & Industrial

Gas-Fired Unit Heaters Commercial & Industrial 6-107.10 February, 2005 Gas-Fired Unit Heaters Commercial & Industrial GRAVITY VENTED PD, BD POWER VENTED PDP, BDP, HD SEPARATED COMBUSTION PSH, BSH, HDS GAS-FIRED, GRAVITY-VENTED UNIT HEATERS Low Initial

More information

EHH SERIES DRAW THROUGH FAN COILS CFM

EHH SERIES DRAW THROUGH FAN COILS CFM EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE

More information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Placement within a mechanical room is required for all major mechanical equipment. Only small units may be roof-mounted, and shall be made as inconspicuous

More information

RP, GP, XP Pro Series Installation Instructions

RP, GP, XP Pro Series Installation Instructions RP, GP, XP Pro Series Installation Instructions IN095 Rev B 0718 3 Saber Way, Ward Hill, MA 01835 radonaway.com 1 Fan Installation & Operating Instructions RP, GP, XP Series Fans Please Read and Save These

More information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS *s are Subject to Change without Notice.* REFLECTOR PANS FOR HINGED ELEMENTS Heavy Chromed Steel Description 2-1040 6" UNIVERSAL $2.19 2-1041 8" UNIVERSAL $2.89 2-1050 6" GE/HOTPOINT $2.39 2-1051 8" GE/HOTPOINT

More information

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products Fans s for f Life! CA-TD0708 The World s Leading Producer of Air Movement Products TD In-line Mixed Flow Duct Fans Soler & Palau (S&P) USA and Canada are the most recent additions to, and are wholly owned

More information

Energy Recovery with Cooling and Heating

Energy Recovery with Cooling and Heating Energy Recovery with Cooling and Heating VersiVent - Model VER Commercial Institutional 2,000-10,000 cfm 3.0 in. wg external static pressure Configurable September 2008 Page The VersiVent Header Model

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual READ AND SAVE THESE INSTRUCTIONS PART # 538 Model BCF Belt Drive Centrifugal Cabinet Fans Installation, Operation, and Maintenance Manual Please read and save these instructions for future reference. Read

More information

Energy Recovery with Cooling and Heating Model ERCH

Energy Recovery with Cooling and Heating Model ERCH Energy Recovery with Cooling and Heating Model ERCH 100% Outdoor Air System Dedicated Outdoor Air System 1,000-10,000 cfm 1.75 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating,

More information

A. Codes and Standards that are Standard at the University:

A. Codes and Standards that are Standard at the University: PART 1: GENERAL 1.01 Purpose: 1.02 References: 1.03 Requirements: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The

More information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

VERTICAL FAN COIL UNITS

VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote

More information

PA 500/1100V Ultra Quiet Ventilation Fan

PA 500/1100V Ultra Quiet Ventilation Fan SPECIFICATION SHEET PA 500/1100V Ultra Quiet Ventilation Fan Description Ultra quiet ventilation fan with high efficiency, capacitor start motor, Energy Star and HVI 2100 certified. The PA series is UL

More information

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier RXID-AW90A Whole House Dehumidifier with fresh air ventilation Installation Guide Dehumidification Fresh Air Ventilation Compact Size Energy Efficient The whole house dehumidifier integrates highcapacity

More information

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS ENERGY-SAVING VENTILATION SOLUTIONS TO IMPROVE INDOOR AIR QUALITY Quality Features Built Into Every Model Compact

More information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

Heating Products M arch 2012

Heating Products M arch 2012 Heating Products M arch 2012 Broan Heaters Broan Heaters. Put the comfort you want right where it s needed. 2 Broan Heaters Why spot heating makes sense in your home. Think about it you hastily get ready

More information

Cabinet Unit Heaters Steam / Hot Water

Cabinet Unit Heaters Steam / Hot Water 11-160.4 February, 2005 Cabinet Unit Heaters Steam / Hot Water Model C MODEL IDENTIFICATION Table of Contents I. Model Identification... 3 Page Il. IIl. III. IV. Design Benefits A. Features and Benefits...

More information

Caution: The fans must not be used in bath or shower enclosures.

Caution: The fans must not be used in bath or shower enclosures. The Vitro & Vitro Star represent VENTS s newest innovation of axial extract residential fans. With glass decorative cover the fans are beautiful enrichment to the interiors, an ideal combination of form

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

Product Specifications. Vertical Floor Consoles By First Co.

Product Specifications. Vertical Floor Consoles By First Co. NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series

More information

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ... Installation & Operating Manual RSIF Power Venter USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration... Chapter

More information

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs 3/8, 1/2 and 5/8 inch OD Tubing March 2010 Custom Coils Custom Coils Configured to Meet Your Needs Greenheck is proud to offer a complete

More information

SAFETY AND INSTALLATION MANUAL MODEL 8100

SAFETY AND INSTALLATION MANUAL MODEL 8100 SAFETY AND INSTALLATION MANUAL ENERGY RECOVERY VENTILATORS MODEL 8100 Provides year-round fresh air Recovers 77% of the apparent heating or cooling energy from the exhausted air See Warnings Page 3 Table

More information

M Series Fan Filter Units

M Series Fan Filter Units M Series Fan Filter Units Product Specifications... 2 Safety Instructions... 3 Receiving and Unpacking... 3 Pre-Installation Instructions... 3-4 Installation Instructions... 4 Electrical Installation Instructions...

More information

Residential Fans & Air Purifiers

Residential Fans & Air Purifiers Residential Fans & ir Purifiers ESSORIES Fan ccessories Mounting lamps for Rigid Duct M mounting clamps are designed for use with rigid duct. The foam neoprene layer creates an air tight and solid installation

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS INSTLLTION INSTRUCTIONS HOOD MODELS WSX, WCX, & WEX 35 Thor Place rea, Ca 98 (877) 387-67 IMPORTNT SFETY INSTRUCTIONS PLESE RED ENTIRE INSTRUCTION EFORE PROCEEDING. INSTLLTIONS MUST COMPLY WITH LL LOCL

More information

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2 3002239 RSIF 2014-04-04 Installation and operation manual RSIF power venter READ AND SAVE THESE INSTRUCTIONS! Product information Chapters 1 + 2 Mechanical installation Chapter 3 Electrical installation

More information

Understanding Fan System Effects

Understanding Fan System Effects Fan Application FA/101-99 A technical bulletin for engineers, contractors and students in the air movement and control industry. Understanding Fan System Effects The air moving industry uses a common term

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

For performance and dimensional data, see back page.

For performance and dimensional data, see back page. Continental Fan s AXC in-line centrifugal duct fans are designed for residential, commercial and industrial ventilation applications. The uiet and efficient backward-curved impeller is capable of developing

More information

Air in Motion. Fan Guide Book February 2004 FB-0204

Air in Motion. Fan Guide Book February 2004 FB-0204 Air in Motion Fan Guide Book February 2004 FB-0204 Find the Fan that Fits Page by page, product by product, this Fantech Guide Book offers you ventilation solutions to meet a wide variety of residential

More information

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Part #459023 Energy Recovery Ventilators Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

Modular Heating & Ventilating Unit Model IGX-HV

Modular Heating & Ventilating Unit Model IGX-HV Modular Heating & Ventilating Unit Model IGX-HV Indirect Gas-Fired Heating Evaporative Chilled Water DX Cooling October 2008 Product Features Model IGX-HV Indirect Gas-Fired Heating and Ventilating Unit

More information

RP / RPc Series Installation Instructions

RP / RPc Series Installation Instructions c RP / RPc Series Installation Instructions 1 Fan Installation & Operating Instructions Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE

More information

QUICKSHIP PROGRAM. Twin City Fan QuickShip

QUICKSHIP PROGRAM. Twin City Fan QuickShip QUICKSHIP PROGRAM QUICKSHIP PROGRAM Twin City Fan & lower stocks a large number of products for quick shipment, so your tight project deadlines can be met and downtime on replacement work can be held to

More information

SeasonMaker ThinLine Fan-coil Units

SeasonMaker ThinLine Fan-coil Units Catalog C: 720-12 SeasonMaker ThinLine Fan-coil Units Type TSH & TSC Horizontal Design TSS, TPF, TSF & TSB Vertical Design C L I S T E D Ratings Certified by the Air Conditioning & Refrigeration Institute

More information

SF180 Installation Instructions

SF180 Installation Instructions SF180 Installation Instructions 1 Fan Installation & Operating Instructions Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL

More information

Ultra SERIES. BroanUltra.ca. Broan-NuTone Canada Inc Tristar Drive Mississauga, Ontario L5T 1H /12

Ultra SERIES. BroanUltra.ca. Broan-NuTone Canada Inc Tristar Drive Mississauga, Ontario L5T 1H /12 Ultra SERIES Ventilation Fans Broan-NuTone Canada Inc. 1140 Tristar Drive Mississauga, Ontario L5T 1H9 877-896-1119 BroanUltra.ca 87529 11/12 Ultra SERIES Ventilation Fans We ve Revolutionized the Ventilation

More information

SECTION AIR DUCT ACCESSORIES

SECTION AIR DUCT ACCESSORIES SECTION 23 33 00 AIR DUCT ACCESSORIES PART 1 - GENERAL 1.1 SUMMARY A. Section includes back-draft dampers, combination fire-and-smoke dampers, duct access doors, fire dampers, smoke dampers, volume control

More information

Submittal Data Performance Data Electrical Data

Submittal Data Performance Data Electrical Data ERMS Series Submittal Data Submittal Data Unit Designation: Job name: Architect: Engineer: Contractor: Performance Data Revision: 07/01/11 Cooling Capacity: EER: Heating Capacity: COP: Ambient Air Temp:

More information

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

Energy Guide. Fan Efficiency Grades. FEG Ratings. July Energy Guide Fan Efficiency Grades s July 2013 Certified Fans Location Mounting Airflow Application Drive Type Impeller Type Performance Model Outdoor Indoor Roof Curb Base/Floor Hanging Wall Ceiling Mounted

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS 036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The

More information

DOMEKT. Heat Recovery Air Handling Units

DOMEKT. Heat Recovery Air Handling Units Heat Recovery ir Handling Units OMKT Heat Recovery ir Handling Units OMKT KOMFOVNT OMKT air handling units Komfovent air handling units are made to create healthy indoor climate and ensure efficient energy

More information

GreenJet Transfer Fans

GreenJet Transfer Fans GreenJet Transfer Fans Model GJX High Performance Axial Transfer Fan April 2018 GreenJet As cars park in an underground parking structure, carbon monoxide (CO) and other noxious fumes are emitted into

More information

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS New Construction Model Model EGN Superior Sound Performance Operating and Transmission Loss (OITC) High Efficiency 42 x 16 Wall Sleeve Semi-Custom Options Modern

More information

RSIF Power Venter. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

RSIF Power Venter. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS Installation & Operating Manual 3002239 09.03 USA CAN RSIF Power Venter READ AND SAVE THESE INSTRUCTIONS 1200 Northmeadow Parkway, STE 180 Roswell, GA 30076 (770) 587-3238 (800) 255-2923 Fax (770) 587-4731

More information

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS New Construction Model Model EGN Superior Sound Performance Operating and Transmission Loss (OITC) High Efficiency 42 x 16 Wall Sleeve Semi-Custom Options Modern

More information

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260)

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260) Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN 46706 (260) 925-6550 Fax: (260) 925-6093 Industrial Facility Midwest Re: Facility Ventilation Audit Schust Engineering, Inc. is pleased

More information

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004) High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

Deluxe Oil-Filled Heater. Heating Capability: 1,000 sq. ft

Deluxe Oil-Filled Heater. Heating Capability: 1,000 sq. ft Electric Heaters Electric Heater Fan apability: 800 sq. ft 750 / 1,500 / fan only 8387243 2.5 lb...21 eluxe Oil-Filled Heater apability: djustable thermostat. Safety tip-over switch. Swivel wheels for

More information

SECTION AIR HANDLING UNIT

SECTION AIR HANDLING UNIT SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR

More information

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013 SECTION 15800 - AIR HANDLING EQUIPMENT 1.1 GENERAL A. All air handlers installed shall conform to the University of Rochester specification Guideline for Semi-Custom and Pre-Engineered Air Handling Units.

More information

1.1 This section applies to air handling units for HVAC Systems.

1.1 This section applies to air handling units for HVAC Systems. AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling

More information

Ultra SERIES. A revolution in ventilation fan technology

Ultra SERIES. A revolution in ventilation fan technology Ultra SERIES Ventilation Fans A revolution in ventilation fan technology Introducing ULTRA S A Revolution in Ventilation Fan Technology En We didn t just change one thing to make installation faster we

More information

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions. Page 1 of 8 RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE

More information

Heat Recovery Air Handling Units

Heat Recovery Air Handling Units Heat Recovery ir Handling Units OMEKT Heat recovery air handling Units OMEKT 1 KOMFOVENT OMEKT ir Handling Units Komfovent ir Handling units are made to create healthy indoor climate and ensure efficient

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual PN 08 Models SQ and SQ entrifugal Inline ans Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

Bathroom Exhaust Fan/Fluorescent Light Combination

Bathroom Exhaust Fan/Fluorescent Light Combination Bathroom Exhaust Fan/Fluorescent Light Combination MODEL: 8663RF Suitable for use in shower or tub enclosure when used with GFCI protected branch circuit. The exhaust fan consists of the housing, power

More information

Technical and Dimensional Data. Saf-T Vent SC Plus

Technical and Dimensional Data. Saf-T Vent SC Plus Technical and Dimensional Data Saf-T Vent S Plus 3"/5" & 4"/7" oncentric Reduced learance Double Wall for Special Gas Vent and/or Sealed ombustion Systems lso For Venting Listed Gas or Oil Fired ppliances

More information