1 Ventilation Dryer for Hydraulic Units When using hydraulic units, humid air is sucked in by pressure equalization with the environment, which condensate when the temperature drops below the dew point. The use in high humidity and temperature fluctuations can lead to condensation damage. Rapid aging of the hydraulic oil, the degradation of additives and the promotion of corrosion are only a few possible damages. To prevent damage caused by condensation, the use of a ventilation dryer is a very good measure. The incoming supply air is dried and thus a strong reduction in the water content and the dew point is achieved. While a well-designed ventilation dryer protects the hydraulic unit very efficiently, handling is very easy. The color change of the silica gel from orange to green indicates the status of the adsorber. GIEBEL FilTec has developed the VARIO and VENT series for protection of hydraulic power packs. GIEBEL FilTec GmbH Web info@giebel-adsorber.de Tel +49 (0) /5
2 Use of the series VARIO Special feature: Stable aluminum valve part, large frost-proof aluminum valves, pre-filter disc for dust, oil master for outflowing air Areas of application: Longer maintenance intervals, larger tank volumes, dusty ambient conditions, high air throughputs, high oil mist emissions Advantages: Disadvantages: Excellent air drying, no sticking or freezing of the valves, separation of oil aerosols, easy handling without tools, long maintenance intervals due to high quantity of drying agent Higher construction by valve part Use of the series VENT Special feature: Smaller dimensions, easy assembly, larger choice of sizes Areas of application: Restricted installation conditions, smaller tank volumes, lower air flow rates Advantages: Disadvantages: Reasonable purchase costs, low installation dimensions Valves not suitable for very dusty or very cold environments, no adequate oil separation during oil mist emission GIEBEL FilTec GmbH Web Tel +49 (0) /5
3 VENT PA-D VENT PA-R VARIO PA-D VARIO PA-R VARIO MA VARIO ME Valves Refillable Use according to ATEX 2014 Offshore / Marine suitable Tank volume / Air flow rate 0 50 l up to 10l/min, max. 30l/min 0 50 l up to 10l/min, max. 30l/min l up to 20l/min, max. 100l/min l up to 20l/min, max. 100l/min vv 120-PA vv 140-PA vv 200-PA vv 220-PA vv 130-PA vv 150-PA vv 210-PA vv 230-PA l up to 40l/min, max. 260l/min l up to 80l/min, max. 490l/min l up to 110l/min, max. 610l/min l up to 160l/min, max. 930l/min l up to 210l/min, max. 1250l/min vv 300-PA vv 310-PA DV 300-PA DV 310-PA DV 310-MA DV 310-ME vv 320-PA vv 330-PA DV 320-PA DV 330-PA DV 330-MA DV 330-ME vv 500-PA vv 510-PA DV 500-PA DV 510-PA DV 510-MA DV 510-ME vv 520-PA vv 530-PA DV 520-PA DV 530-PA DV 530-MA DV 530-ME DV 550-PA DV 560-PA DV 560-MA DV 560-ME up to 260l/min, max. 1450l/min up to 410l/min, max. 2000l/min up to 530l/min, max. 2000l/min DV 730-MA DV 760-MA DV 790-MA DV 730-ME DV 760-ME DV 790-ME GIEBEL FilTec GmbH Web info@giebel-adsorber.de Tel +49 (0) /5
4 Flange with sieve, sealing and screws Installation of an adsorber on standard bolt circle 73mm according to DIN Filling adapter with bolt circle 73mm or thread connection 40mm filling opening, without disassembling the adsorber Sidestream adapter with bolt circle 41,3mm, 73mm or thread Filter system for the preparation of oil in the side stream, no additional opening necessary Pressure display with bolt circle 73mm or thread connection For the visual display of a blocked filter from 80mbar negative pressure Assembly tube Straight or as Z form If space is tight for flexible mounting of an adsorber Wall bracket With or without stainless steel hose and oil sight glass It is also possible to install an adsorber on remote buildings GIEBEL FilTec GmbH Web info@giebel-adsorber.de Tel +49 (0) /5
5 Areas of application for GIEBEL Adsorber are Floodgate & canal in steel water construction Conveyors in mining and opencast mining Machines for pulp and paper production Flight and driving simulators Work equipment on rail vehicles Offshore and marine technology Horizontal tunnel boring machines Injection molding machines Presses and rolling machines and many more GIEBEL FilTec GmbH Web Tel +49 (0) /5
Assembly and Maintenance manual according to regulation DIN 82079
Assembly and Maintenance manual according to regulation DIN 82079 VARIO VG Version 4.16 Part 1 Information to the manufacturer Giebel FilTec GmbH Carl-Zeiss-Str. 5 DE-74626 Bretzfeld-Schwabbach Tel. +49
More informationAssembly and Maintenance manual according to regulation DIN DV TB 310-MA, DV TB 330-MA DV TB 510-MA, DV TB 530-MA DV TB 560-MA
Assembly and Maintenance manual according to regulation DIN 82079 VARIO TB Version 4.16 Part 1 Information to the manufacturer Giebel FilTec GmbH Carl-Zeiss-Str. 5 DE-74626 Bretzfeld-Schwabbach Tel. +49
More informationAssembly and Maintenance manual according to regulation DIN 82079
Assembly and Maintenance manual according to regulation DIN 82079 MTROC Version 4.16 Part 1 Information to the manufacturer Giebel FilTec GmbH Carl-Zeiss-Str. 5 DE-74626 Bretzfeld-Schwabbach Tel. +49 (0)
More informationMaterial Safety Data Sheet according to Regulation (EC) No. 1907/2006. Composition/Information on Ingredients
Version 2.16 Material Safety Data Sheet according to Regulation (EC) No. 1907/2006 Part 1 Silica gel E orange Information to the supplier/distributor Giebel FilTec GmbH Carl-Zeiss-Str. 5 DE-74626 Bretzfeld-Schwabbach
More informationContinental and Lycoming typically rate their
nuts & bolts maintenance & restoration Power Plant Insurance Make your own engine dehumidifier DAVE BARKER, EAA 587700 Continental and Lycoming typically rate their engine life from 1,600 to 2,000 hours
More informationECON Pellet Dryer S+L. for drainage and drying of synthetic granules and recycling material
Pellet Dryer S+L ECON Pellet Dryer S+L for drainage and drying of synthetic granules and recycling material APPLICATION AREAS S+L drainage and drying of synthetic granules after underwater pelletizer after
More informationAdsorption dryer SDAT
Solutions to your fluid power problems Adsorption dryer SDAT Operating instructions Issue 04/2004 DRUMAG GmbH Fluidtechnik Glarnerstrasse 2 D-79713 Bad Säckingen Telefon: +49 (0)7761 / 5505-0 Fax: +49
More informationAIR SENTRY DESICCANT BREATHERS
AIR SENTRY DESICCANT BREATHERS Extending fluid life saves money and downtime GUARDIAN BREATHERS There is no such thing as too much reliability 1 Silica Gel, Carbon 25 cfm/187 gpm Optional Yes GUARDIAN
More informationThe leader in gas dehydration & filtration
The leader in gas dehydration & filtration wellhe ad production instrument and fuel gas l andfill & digester gas coal-bed methane off shore Van Gas Technologies specializes in natural gas and biogas dehydration
More informationDRI-AIR INDUSTRIES, INC. AHM-1C HOPPER MOUNT DRYER OPERATING MANUAL
AHM-1C HOPPER MOUNT DRYER OPERATING MANUAL Page 1 DRI-AIR INDUSTRIES, INC. 16 THOMPSON ROAD P.O. BOX 1020 EAST WINDSOR, CT 06088-1020 Tel. (860) 627-5110 FAX (860) 623-4477 Internet http://www.dri-air.com
More informationBoreas DV DV AVS / WVS Air cooled / water cooled Refrigeration Dryers
Boreas DV 1260 - DV 2 AVS / WVS Air cooled / water cooled Refrigeration Dryers PRODUCT DESCRIPTION Boreas DV 1260 - DV 2 For the energy-conscious user, the new Boreas DV refrigeration compressed air dryers
More informationOperation Manual 322 KL
Operation Manual 322 KL 8/07 von Oertzen GmbH Ferdinand-Harten-Str. 10 22949 Ammersbek Tel. +49 40 604110 Fax +49 40 6041149 www.oertzen-gmbh.de info@oertzen-gmbh.de Table of Content 1. Introduction Page
More informationIndustrial Processing Solutions
Industrial Processing Solutions Fluid power, filtration, and roll cleaning products. Innovative products and technologies. Rotating Unions & Accessories Rotary unions for water and air service ( 3 8 to
More informationEN - english. Instructions for installation and operation. Mobile humidity meter DP 207
EN - english Instructions for installation and operation Mobile humidity meter DP 207 Dear customers, Thank you very much for deciding in favour of the mobile humidity measuring instrument DP 207. Please
More informationKRAL Screw Pumps. L Series.
KRAL Screw Pumps. L Series. Our new Medium Pressure Pump The new L pump makes life easier sturdy, with a low wear rate and easy to maintain. How the L pump fits into the KRAL product Applications. range.
More informationBoreas DV DV AB / WB
Boreas DV 1260 - DV 2 AB / WB Air cooled / water cooled Refrigeration Dryers PRODUCT DESCRIPTION MA FEATURES & BENEFITS Refrigeration compressed air dryer for safe and economical compressed air drying
More informationIDU22C, 22C1, 37C, 37C1, 55C, 75C
Refrigerated ir ryer Series IU edium IU, 1, 7, 71, 55, 75 () () () () () Run light Operation (ftercooler) Stop (ftercooler) Outlet air pressure gauge vaporation () (I) () Terminal block () () P rain port
More informationHL Hydraulik GmbH SCHRUPP GAS DRYER STATIONS GAS DRYER STATIONS. Optional with Bypass.
SCHUPP GAS DYE STATIONS SCHUPP GAS DYE STATIONS Optional with Bypass For compressed Air and other non- aggressive gaseous media: - drying - de-oiling - filtering this means - less corrosion - less wear
More informationDRI-AIR INDUSTRIES, INC. AHM-1B HOPPER MOUNT DRYER OPERATING MANUAL
AHM-1B HOPPER MOUNT DRYER OPERATING MANUAL Page 1 DRI-AIR INDUSTRIES, INC. 16 THOMPSON ROAD P.O. BOX 1020 EAST WINDSOR, CT 06088-1020 Tel. (860) 627-5110 FAX (860) 623-4477 Internet http://www.dri-air.com
More informationWaveguide Dehydrators
Waveguide Dehydrators Clean & Dry Air For Clear Communications Rugged & Reliable Compressed Air Systems for: TV and Radio Broadcast Applications Satellite Radar Aerospace Telecommunications Military Custom
More informationWhen considering the purchase of a walk-in you most likely will be looking for the following things.
BUYING A WALK-IN COOLER OR FREEZER When making a decision on which walk-in cooler or freezer to buy, there are many things that must be considered. In the following guide we hope to go through all these
More informationInstallation, Operation and Maintenance Instructions Electric Flow Heater OM009
Installation, Operation and Maintenance Instructions Electric Flow Heater OM009 Calorifiers Heat Exchangers Pressurisation Units Sales Tel: 01457 835700 Sales Fax: 01457 832700 E-mail: sales@gmsthermal.co.uk
More informationPressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications
Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description
More informationRail vehicles without compressed air? Practically inconceivable!
Rail vehicles must have a reliable braking system. They generally use compressed air, which is generated by screw compressors. Photo: Fotolia / VRD Rail vehicles without compressed air? Practically inconceivable!
More informationNEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!
NEW 4,6,8,16,24,30 APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS! www.welchvacuum.com/crvpro Discover the evolution of two-stage rotary vane vacuum pumps. Built to last. Born to perform. And designed to simplify
More informationHigh Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY
High Efficiency Compressed Air Dryers Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY Adsorption Dryers Modular System Compressed air purification equipment must deliver uncompromising performance
More informationOperating instructions Open two-stage compressor FZ 16
Page 1 Operating instructions Type: FZ 16 / 2051- R 22 FZX 16 / 2051- R 404 A FZX 16 / 2051- R 410 A Page 2 Contents Page 1. Safety instructions...3 2....3 3. Brief description...3 4. Main and function
More informationPelletizing System Options for Extrusion
Pelletizing System Options for Extrusion by Dana Darley Extrusion Auxiliary Serv ices Dacula, GA (678) 714-5218 www.extrusionauxiliary.com Types of Pelletizing Systems Strand Water Bath Strand Water Slide
More informationDESICCANT AIR DRYERS. BD + CD + CD series
DESICCANT AIR DRYERS BD + CD + CD series AIR TREATMENT, A CRUCIAL INVESTMENT WHY YOU NEED QUALITY AIR Compressed air contains oil, solid particles and water vapors. Together, they form an abrasive, often
More informationCustomers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation
EN Customers. The core of our innovation Feeding&Conveying Drying Dosing Temperature Control Refrigeration Granulation Piovan Drying Technologies: Desiccant Bed Dryers Dried air is generated by means of
More informationA-DRY Heatless adsorption compressed air dryers
A-DRY 6-05 Heatless adsorption compressed air dryers A-Dry - Adsorption compressed air dryer Four individually controlled valves To provide optimum control over the complete drying process four high quality
More informationTransformer Breathers
Transformer Breathers Protection against: High humidity Water condensation Pressure variations Dielectric loss Mould growth Outgassing Innovative Products and Services for the Modern Power Industry www.brownell.co.uk
More informationHigh Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value
High Inlet Temperature Air Dryer Membrane Air Dryer After-Clooler Oil-Water Separator Automatic Value 1 2 3 4 5 6 7 8 9 1 HYD model Control Panel 1. on HYD-150 and smaller - It is equipped with a low pressure
More informationNEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!
NEW APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS! www.welchvacuum.com/crvpro Discover the evolution of two-stage rotary vane vacuum pumps. Built to last. Born to perform. And designed to simplify your work.
More informationProportioners for Stationary Extinguishing Systems
Proportioners and Monitors for Fire-Fighting FireDos Proportioners for Stationary Extinguishing Systems Deluge systems Seawater extinguishing systems Sprinkler systems Foam extinguishing systems About
More informationSafety vacuum drying oven for flammable solvents
VDL series 53 Vacuum drying ovens Safety vacuum drying oven for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with
More informationAPPLIED VACUUM TECHNOLOGY VACUUM PUMPS & SYSTEMS
APPLIED VACUUM TECHNOLOGY VACUUM PUMPS & SYSTEMS www.welchvacuum.com/crvpro Discover the evolution of two-stage rotary vane vacuum pumps. Built to last. Born to perform. And designed to simplify your work.
More informationRemeha. Fuel oil/gas boilers P 520. Installation and Service Manual A
Remeha Fuel oil/gas boilers EN Installation and Service Manual 300016859-001-A 63115 Declaration of conformity The appliance complies with the standard model described in declaration of compliance. It
More informationInstallation, Operation and Maintenance Manual
Installation, Operation and Maintenance Manual Packaged Chiller Models CC 6601, 6501, 6401, 6301, 6201, 6101 For Service, please contact Pfannenberg Service Company: U.S.A. Pfannenberg Inc. 68 Ward Road.
More informationMoisture can be very disruptive to a dust. Preventing moisture problems in your dust collector
As appeared in March 2017 PBE Copyright CSC Publishing www.powderbulk.com Preventing moisture problems in your dust collector Brian Mathews Scientific Dust Collectors This article discusses how moisture
More informationVIESMANN VITOCROSSAL 300 Gas condensing boiler 187 to 635 kw
VIESMANN VITOCROSSAL 300 Gas condensing boiler 187 to 635 kw Datasheet Part no. and prices: see pricelist VITOCROSSAL 300 Type CT3B Gas condensing boiler for natural gas E, LL and LPG With modulating MatriX
More informationOK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.
INSTALLATION, OPERATION & SERVICE MANUAL FOR COOLER TYPES OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. 1. Introduction This manual is a guide for the installation, maintenance
More informationHeated tools. Semiconductor equipment
Heated tools Semiconductor equipment Ceramic heating elements made of silicon nitride and aluminum nitride can be manufactured as tools in various shapes. The heating function can be integrated in complex
More informationProduct overview Suction Guns, suction machines, Vac-Blast Cleaners
Product overview Suction Guns, suction machines, Vac-Blast Cleaners micro-cleaning for your products 3300_EN_20141020_Sauggeraete_Gesamtprogramm TiS Intelligent air utilisation Compressed air passes a
More informationCompressed air preparation Compressed air storage Moisture management. Catalog #1
Compressed air preparation Compressed air storage Moisture management Catalog #1 This Catalogue is valid from May 2015. All previous catalogues lose their validity with the publication of the new catalogue.
More informationSelection and projecting of compressed air generation in railbound vehicles
Compressed air generation Technology_ Selection and projecting of compressed air generation in railbound vehicles By Dieter Reinger and Hans Lütte, Rheinfelden*) General Interfaces for Compressed Air Generation
More informationHot Water Circulator Pump LRP
Hot Water Circulator Pump LRP Contents. Introduction.... Safety Instruction... 3.Product Structure... 4 4. Technical Parameters... 7 5. Precautions... 8 9. Troubleshooting Disconnect power supply before
More informationProduct Overview: SOMOS dryer type series Manfred Horsch - Head of Sales Area South/D-A-CH Region, West Europe
January 14, 2016 Product Overview: SOMOS dryer type series Manfred Horsch - Head of Sales Area South/D-A-CH Region, West Europe What s new? Targets for redevelopment According to Strategic Plan ProTec
More informationSpare parts list. Hydraulic compactor RC
Spare parts list Hydraulic compactor RC 150 RC 150 Valid from serial number BGF0102397 Valid to serial number www.cp.com RC 150 Spare parts list General information This spare parts list applies to the
More informationNEWGATE TECHNOLOGIES, INC.
www W.newgatetechnologies.com NEWGATE TECHNOLOGIES, INC. Installation & Operations Manual SYNERGY Series High Inlet Temperature Refrigerated Air Dryers Models SYNERGY 025 ~ SYNERGY 125 Includes Safety
More informationBOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series
BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series Over 100,000 compressed air users expect more when it comes to their compressed air supply. BOGE air provides them with the air to work. If it is
More informationDESICCANT AIR DRYERS. BD + CD + CD series
DESICCANT AIR DRYERS BD + CD + CD series AIR TREATMENT, A CRUCIAL INVESTMENT WHY YOU NEED QUALITY AIR Compressed air contains oil, solid particles and water vapors. Together, they form an abrasive, often
More informationHigh Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY
High Efficiency Compressed Air Dryers Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY Adsorption Dryers Modular System Compressed air purification equipment must deliver uncompromising performance
More informationultra.dry heat regenerated adsorption dryer
ultra.dry heat regenerated adsorption dryer Why drying compressed air? Compressed air is used in almost all areas of industrial manufacturing as a source of energy or processing. Compressed air needs to
More informationBINDER Scientific Product Catalog
BINDER Scientific Product Catalog 36 Vacuum drying ovens Vacuum drying ovens 37 VD VDL VDL EX-Zone 2 Absolutely reliable drying Drying with no residues, no danger of incrustation, no oxidation all under
More informationDRYAIRE DESICCANT SYSTEM MODEL 6760
MODEL 6760 THE SPRAY GUN PEOPLE FOR PRODUCT INFORMATION CALL: 1-800-742-7731 System Description Sharpe s DRYAIRE Desiccant Air Drying System is the painter s insurance for removing dirt, water, oil, and
More informationproductdatasheet Compressed Air Refrigeration Dryer Efficient compressed air treatment Rev 01_0317 Page 1
ECOTROC KTN Compressed Air Refrigeration Dryer Efficient compressed air treatment Rev 0_07 Page KSI Filtertechnik GmbH Siemensring 5-56 D-7877 Willich Tel. +9 5 89 08-0 Fax +9 5 8908-8 www.ksi.eu mail@ksi.eu
More informationVacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
More informationGüntner Info. finoox technology. fin and tube heat exchangers. Tailor-made solutions!
Güntner Info finoox technology fin and tube heat exchangers Tailor-made solutions! Heat exchangers Knowledge-based engineering Special Air Conditioning and Refrigeration applications and the cooling of
More informationTN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.
TN-25 Tunnel Fire Protection System Safer. Smarter. Tyco. Expert Fire Protection for Tunnels Tyco provides a complete fire protection solution to protect the infrastructure of tunnels. Whether it is rail,
More informationThe Flush Kit: The perfect companion to Harvest Right home freeze dryers. The Flush Kit. User s Manual
The Flush Kit: The perfect companion to Harvest Right home freeze dryers The Flush Kit User s Manual Freeze Dryer Accessories LLC 2608 W. 510 N. Hurricane, UT 84737 (435)215-5136 web: freezedryeraccessories.com
More informationInstallation and Maintenance Instructions
Installation and Maintenance Instructions Screw Vacuum Pumps COBRA Version with variator Busch Manufacturing Korea, Ltd. 189-51, Soicheon-ro, Majang-myun Icheon-si, Gyunggi-do, 467-813 Republic of Korea
More informationFilters & Centrifugal Separators
www.kaeser.com s & Centrifugal Separators Flow rates 0.8 to 8 m³/min Why use compressed air filters? On average, a compressor sucks in up to 90 million particles of dirt, hydrocarbons, viruses and bacteria
More informationBC BRONCOS AIR CONDITIONING UNIT
BC BRONCOS AIR CONDITIONING UNIT CAUTION If you are not familiar with the principals of air conditioning, have an authorized air conditioning technician evacuate and charge the system. Serious damage to
More informationTECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION
TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION Having an understanding of why water forms in your compressed air piping system will help you in evaluating the type of air drying system
More informationTechnology for Vacuum Systems. Instructions for use
page 1 of 8 Technology for Vacuum Systems Instructions for use GKF 1000i Cold trap page 2 of 8 Content Safety information!...3 General information...3 Intended use...3 Setting up and installing the cold
More informationThermal Oil Heating System. Heat Recovery System. Member of the
Thermal Oil Heating System Heat Recovery System Member of the Thermal Oil Heating System Using energy efficiently and successfully when baking DAUB sets trends in developing ovens based on the Thermal
More informationInstallation plan: PG Mat. no Version 00 US
Installation plan: PG 8504 Mat. no. 10 344 110 Version 00 US Technical data sheet PG 8504 Legend: Circled, bold-type abbreviations: Connection required Abbreviations surrounded by broken circle: Connection
More informationVC-1, VC-1-SL, VC-2-L, VC-2-SL
Pre-Cooling Unit Series VC VC-1, VC-1-SL, VC-2-L, VC-2-SL Instruction Manual Version 1.00.02 Dear customer, we have made up this operating manual in such a way that all necessary information about the
More informationTQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.
TQ Series Electronic Control Pump Instruction Manual 50Hz ISO 9001 Certified Walrus Pump Co., Ltd. EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No. 83-14, Dapiantou, Sanjhih
More informationPHIREX AUSTRALIA CATALOGUE & DATA SHEETS. April 2005, Rev 2. Fogex Water Mist Fire Protection System Components PHX-3064
CATALOGUE & S April 2005, Rev 2 PHX-3064 Fogex Water Mist Fire Protection System Components Fogex F11 Water Mist Nozzle Fogex F11 Water Mist Nozzle Features Al. Bronze construction for added safety and
More informationAlarmLine Addressable Linear Heat Detector
Line Addressable Linear Heat Detector P/N 7-0001-00 Effective: March 2008 K-7-02 FEATURES UL Listed FM Approved CSFM MEA (pending) Low-cost interface between Line sensor cable and control panel accepting
More informationHazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs
Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs Part #: HALP-ANC-48-2L-LED-D-V2 Page: 1 Made in the USA The Larson Electronics HALP-ANC-48-2L-LED-D-V2
More informationEW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS
Design Hydronic meters of the EW447-452 Series consist of: Electronic energy integrator with fixed cable connection to the volume measuring component, supply and return temperature probe Mechanical volume
More informationAdsorption Dryers for Compressed Air
Adsorption Dryers for Compressed Air ADS 1 to 215 Clean and dry air. Prevent the risks, enjoy the benefits. AVAILABILITY PARTNERSHIP SERVICEABILITY TECHNOLOGY YOU CAN TRUST RELIABILITY SIMPLICITY AVAILABILITY
More informationDesiccant Breathers: A Front Line Defense in the War on Contamination
LE White WHITE PAPER Paper : A Front Line Defense in the War on Contamination 2015 Lubrication Engineers, Inc. The Lubrication Reliability Source 1 www.lelubricants.com 800-537-7683 Introduction Are you
More informationOperation Refilling and Maintenance Manual SFS-10. Hatsuta Seisakusho Co. Ltd. SFS-10-E1404-(A-012)
Operation Refilling and Maintenance Manual SFS-10 Hatsuta Seisakusho Co. Ltd. 1. Fire Classification Normal Combustibles (A Class) and Oil and Flammable Liquid Fires (B Class) 2. Fire Extinguishing Mechanism
More informationSWITCH PRODUCTS SAFETY & SIGNAL MATS SENSING EDGES SENSING BUMPERS INTERFACE CONTROLLERS LIGHT CURTAINS CUSTOM DESIGNS
A full spectrum of sensing and signaling Celebrating 50 Years of Excellence products for protection, detection, and safety 1957 In Safety and Sensing 2007 SWITCH PRODUCTS SAFETY & SIGNAL MATS SENSING EDGES
More informationNew standard in compressed air treatment, providing Energy Savings up to 99%
PCM Series Specification for APAC Model Flow Capacity (Nm 3 /min) Pressure Dew Point ( ) Power Consumption (kw) Power Supply (V/Ph/Hz) Inlet/Outlet Connections Weight (kg) Dimensions (H x W x D mm) Refrigerants
More informationOperating instructions for semi-hermetic motorcompressors
Operating instructions Page 1 Operating instructions Type: HG 4/310-8/4 S HG 4/385-8/4 S HG 4/465-8/4 S HG 4/555-8/4 Page 2 Page 3 Contents Page 1. Safety instructions...4 2. Main and functional parts...4
More informationAir treatment solutions. Aftercoolers & condensate treatment
Air treatment solutions Aftercoolers & condensate treatment RELIABLE AND CLEAN AIR Atlas Copco aftercoolers and condensate treatment The air that leaves a compressor reaches 100% humidity. It also contains
More informationHYGROPHIL H process hygrometer
HYGROPHIL H 4230-10 process hygrometer Continuous humidity measurement in industrial processes. For very high demands in terms of being resistant to corrosion and dirt. Particularly suitable for cases
More informationEnzo Concealed Shower Mixing Valve
Enzo Concealed Shower Mixing Valve EZ40010CP, EZ40013CP & EZ40014CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible.
More informationEcono-Coat RCM 8000 Powder Spray Booth Installation Guide
Installation Guide P/N 1028657A Econo-Coat RCM 8000 Powder Spray Booth Installation Guide WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this
More informationV80-H Multistage Pump Instruction Manual
V80-H Multistage Pump Instruction Manual PRODUCT OVERVIEW The VADA horizontal multistage centrifugal pumps combine the functional benefits of centrifugal pumps and the practical benefits of self priming
More informationAND NATURAL GAS DRILLING AND PRODUCTION
Offshore Oil AND GAS Drilling and production platforms Thaw Heaters Immersion heaters aid in the vaporization of liquid natural gas (LNG) during transportation and distribution. Top-Up Heaters Circulation
More informationAerslim Fancoil unit. Technical information manual. Western Airconditioning B.V. Tel. +31 (0)
Aerslim Fancoil unit Technical information manual Western Airconditioning B.V. Tel. +31 (0) 33 247 78 00 www.western.nl INDEX 1-INTRODUCTION... 2 2-OPERATING RANGE... 2 3-RADIANT PLATE... 2 4-CODE COMPORISION
More informationSite Specifications for the. INDUSTREX M37 Plus NDT Filmprocessor
Site Specifications for the INDUSTREX M7 Plus NDT Filmprocessor Colenta Labortechnik GmbH & Co KG 2015 27MAR15 Colenta RDM4-4_01 1 Basics The film processor is designed so that only cold water supply,
More informationTF Series With SECOPAC LS
SECOTEC Refrigeration Dryers TF Series With SECOPAC LS Flow rate 17.0 to 34.0 m³/min SECOTEC TF The next generation: Even more efficient compressed air drying SECOTEC that's the name of KAESER's renowned
More informationMULTI-STAGE COMPONENT CLEANING MACHINES
MULTI-STAGE COMPONENT CLEANING MACHINES For efficient cleaning Multi-stage cleaning machine In automated TEIJO multi-stage cleaning machines, a rotary spray system sprays hot cleaning liquid onto stationary
More informationP3X Series Membrane dryers
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding P3X Series Membrane dryers Catalogue no. PDE2640TCUK - April 2010 WARNING
More informationModule 7: Air Supply System
Terms and Definitions Components of the Air Supply System Basic Functions of the Air Supply System Parts of a Compressor Characteristics of Compressors Loading and Unloading Process Characteristics of
More informationReady-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing
Ready-to-Use Heat Tracing Solutions for Laboratory Applications innovations in heat tracing eltherm GmbH Solutions with Electric Heat Tracing Systems eltherm GmbH is an internationally operating engineering
More informationGAW - WCCAP recommendation for aerosol drying
GAW - WCCAP recommendation for aerosol drying Alfred Wiedensohler and Wolfram Birmili Leibniz Institute for Tropospheric Research Humidity control One particular problem during summertime or in warm and
More informationProgramme. High-Pressure Water Jet Technique
Programme High-Pressure Water Jet Technique Pumps Systems Applications WOMA designs, manufactures and markets high-pressure plunger pumps and high-pressure water jet systems with manually or manipulator-guided
More informationJONES Membrane Vent is designed to protect enclosures and devices from particles, water, oil, and other
Membrane Vent Product Description JONES Membrane Vent is designed to protect enclosures and devices from particles, water, oil, and other liquids without negatively affecting their operation. It is comprised
More informationUltraDry s Features and Benefits
pneuaire UltraDry s...........................................3-5 Features and Benefits..............................................................................3 How to Order....................................................................................4
More information50 - WMS // Straight resistance thermometers with a metal thermowell and a built-in measurement insert
50 - WMS // Straight resistance thermometers with a metal thermowell 50-WMS and a built-in measuring insert The 50-WMS product group comprises ready-to-install large and small straight resistance thermometers
More informationOperating Instructions
Operating Instructions Typ TEKA CAREMASTER TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0) 2863 9282-72
More informationFreezertech Horizontal Plate Freezers Engineered for capacity
Freezertech Horizontal Plate Freezers Engineered for capacity Horizontal Plate Freezers Freezertech horizontal plate freezers are world renowned for their strong, long lasting construction, with an ergonomic
More information