Short Form Ventilation Product Guide

Size: px
Start display at page:

Download "Short Form Ventilation Product Guide"

Transcription

1 Uniclass L7534 CI/SfB (57) X FVSF-2 May 2015 Short Form Ventilation Product Guide

2 FERROB VENTILATION design, manufacture and install specialist domestic and light commercial ventilation products for landlords, Local Authorities and Housing Associations, as well as home owners throughout the UK. Our energy efficient ventilation products range from simple extractor fans to technically advanced, electronically controlled devices with digital humidity displays. Ferrob Ventilation s expertise and experience has enabled our products to be developed to control high humidity levels, thereby reducing condensation and mould growth (black mould) in the home effectively. Manufactured in the UK Axial Fans Incorporate impellers that force air to move parallel to the shaft about which the impellers rotate. Axial fans are suited to short duct runs which connect directly to an external outlet or grille. UAX axial fans 100mm Suitable for 150mm Suitable for Extracts 235m³/h at 64l/s Attractively styled for discreet integration within wet room and for ease of cleaning UAX mm for remote switching UAX100S 100mm with pull cord UAX100T 100mm with over-run timer UAX100HTS 100mm with humidity sensor, timer and pull cord UAX100TRS 100mm continuous trickle running with pull cord UAX100PIR 100mm with PIR detector UAX100TRSH 100mm continuous trickle running with pull cord and hour-run meter UAX100LV 100mm for remote switching, UAX100LVS 100mm with pull cord, UAX100LVT 100mm with over-run timer, UAX100LVHTS 100mm with humidity sensor, timer and pull cord, UAX100LVTRS 100mm continuous trickle running with pull cord, UAX100LVTRSH 100mm continuous trickle running with pull cord and hour-run meter, UAX mm for remote switching UAX150S 150mm with pull cord UAX150TRS 150mm continuous trickle running with pull cord UAX150HTS 150mm with humidity sensor, timer and pull cord UAX150TRHTS 150mm continuous trickle running with humidity sensor, timer and pull cord UAX150TRSH 150mm continuous trickle running with pull cord and hour-run meter Mould has the potential to cause many health problems. Indoor mould growth can and should be prevented or controlled by controlling moisture indoors. 2 Call our support team on

3 UAX-ES axial fans with silent electric shutters 100mm Suitable for 150mm Suitable for Extracts 295m³/h at 83l/s UAXES mm for remote switching UAXES100S 100mm with pull cord UAXES100T 100mm with over-run timer UAXES100HTS 100mm with humidity sensor, timer and pull cord UAXES100LV 100mm fan only for remote switching, UAXES100LVS 100mm with pull cord, UAXES100LVT 100mm with over-run timer, UAXES100LVHTS 100mm with humidity sensor, timer and pull cord, UAXES mm only for remote switching UAXES150S 150mm with pull cord UAXES150HTS 150mm with humidity sensor, timer and pull cord SENSORTRONIC axial fans S400HS S400HT S1000 S1000TRS Includes silently operating electronic shutters operated by the thermoactuator Electronic shutters eliminate back draught Attractively styled for discreet integration within wet room and for ease of cleaning 100mm Suitable for 150mm Suitable for Extracts 235m³/h at 64l/s Features an electronic continuously calibrated humidity sensor and light display Attractively styled for discreet integration within wet room and for ease of cleaning 100mm with humidity sensor and pull cord 100mm with humidity sensor and timer 150mm with humidity sensor and pull cord 150mm continuous trickle running wit humidity sensor and pull cord INFINITY 100 Decentralised Mechanical Extract Ventilation (dmev) axial fans with flat front panel INF100REM INF100 INF00T INF100HTS INF100HTS-HR INF100H-SAP INF100LV INF100LVREM INF100LVT INF100LVHTS INF100LVHTS-HR PCH100 PCH100LV RYKINF100 RYKINF100LV 100mm Suitable for Specific Fan Power of 0.70 W/(l/s) on slow speed and 0.50 W/(l/s) on medium speed Provide very quiet levels of continuous ventilation to a single wet room Comply with current Building Regulation requirements Attractively styled for discreet integration within wet room and for ease of cleaning 100mm 3-speed dmev continuous trickle running with remote 100mm 3-speed dmev continuous trickle running with pull cord with remote timer with humidity sensor, remote timer and pull cord with humidity sensor, remote timer and pull cord, with hour-run meter 100mm 3-speed Constant Velocity dmev continuous trickle running with humidity sensor and pull cord (SAP Appendix Q listed) with pull cord, with remote switch, with over-run timer, with humidity sensor, over-run timer and pull cord, with humidity sensor, over-run timer and pull cord, 100mm 3-speed dmev continuous trickle running with pull cord, (for window fitting) 100mm 2-speed 12v dmev continuous trickle running with pull cord (for window fitting), with pull cord and remote-switch 100mm 3-speed dmev continuous trickle running with pull cord and remote-switch, low voltage Call our support team on

4 SENSORTRONIC MICRO axial fans with humidity level infra-red read-out M400HS M400HT M400LVHS M400LVHT M1000 M1500 SENSORTRONIC DIGITAL energy efficient and standard axial fans with integral digital display D400LWHS D400LWHT D1000LW D400HS D400HT D400LVHS D400LVHT D mm Suitable for 150mm Suitable for Extracts 235m³/h at 64l/s Features a set-back humidistat control to eliminate unnecessary running; ideal for night time periods Attractively styled for discreet integration within wet room and for ease of cleaning 100mm with humidity sensor and pull cord 100mm with humidity sensor and timer 100mm with humidity sensor and pull cord, 100mm with humidity sensor and timer, 150mm with humidity sensor and pull cord Humidity level infra-red reader for Micro range of fans 100mm Suitable for Energy Efficient versions: Specific Fan Power of 0.32 W/(l/s) 150mm Suitable for Extracts 235m³/h at 64l/s Energy Efficient versions: Specific Fan Power of 0.17 W/(l/s) Energy efficient versions available to comply with current Building Regulations Features a set-back humidistat control to eliminate unnecessary running; ideal for night time periods Detects and displays humidity levels Attractively styled for discreet integration within wet room and for ease of cleaning 100mm energy efficient with humidity sensor and pull cord, 100mm energy efficient with humidity sensor and timer, 150mm energy efficient with humidity sensor and pull cord 100mm with humidity sensor and pull cord 100mm with humidity sensor and timer 100mm with humidity sensor and pull cord, 100mm with humidity sensor and timer, 150mm with humidity sensor and pull cord Centrifugal Fans Force air to move at right angles to the intake of the fan using centrifugal force. These fans produce more pressure to overcome resistance encountered in longer duct runs and are typically quieter than an axial fan. CF centrifugal fans CF200 CF200S CF200TRS CF200T CF200HTS CF100 CF100S CF100T CF100TRS CF100TRST CF100HTS CF100LV CF100LVS CF100LVT CF100LVTRS CF100LVHTS CF100 Suitable for Extracts 90m³/h at 44l/s CF200 Suitable for Extracts 260m³/h at 73l/s Continuous trickle models available Attractively styled for discreet integration within wet room and for ease of cleaning 100mm for remote switching 100mm with pull cord 100mm continuous trickle running with pull cord 100mm with timer 100mm with humidity sensor, timer and pull cord 100mm for remote switching 100mm with pull cord 100mm with over-run timer 100mm continuous trickle running with pull cord 100mm continuous trickle running with timer 100mm with humidity sensor, timer and pull cord 100mm for remote switching, 100mm with pull cord, 100mm with over-run timer, 100mm continuous trickle running with pull cord, 100mm with humidity sensor, timer and pull cord, 4 Call our support team on

5 In-line Duct Fans Ideal for shower applications, mixed flow fans move air in both an axial and radial direction relative to the shaft and will develop higher air pressure but move less air than axial fans. In-line fans also reduce the need for core-drilling. Positive Input Ventilation (PIV) Units As an effective method for combating mould, condensation and damp issues in residential properties, PIV gently pressurises a dwelling to expel stale and humid air through natural ventilation points, making it ideal for older properties. In-line duct fans ARIDAIR PIV units Suitable for 1004 Extracts 187m³/h at 52l/s 1006 Extracts 520m³/h at 145l/s Ideal for mounting in a loft Extracts a high volume of air 1004 Mixed-flow 100mm 2-speed 1004T Mixed-flow 100mm 2-speed with timer M1004 Mixed-flow 100mm 2-speed fan with M1007 controller and kit* UAX1004 Mixed-flow 100mm 2-speed fan with UAX1007 humidity controller and kit* 1006 Mixed-flow 150mm 2-speed 1006T Mixed-flow 150mm 2-speed with timer *Kit includes 3m of 100mm flexible ducting and 2 grilles as required. S2000LW S2000NI S2000LWH M2000 M2007 S3000LW S3000LWH Helps to eliminate moisture by providing a constant circulation of gently pressurized clean air Temperature cut out models available, in addition to continuous running and manually operated options During warmer periods, solar heat is gained from the loft area Loft mounted with 2-speed manual switch Loft mounted with automatic high / low temperature cut-out Loft mounted with 2-speed manual switch and automatic 100w duct heater Loft mounted humidity controlled with automatic high/low temperature cut-out (supplied with 1 remote humidity sensor) Remote humidity sensor for M2000 Wall mounted with 2-speed manual switch Wall mounted with 2-speed manual switch and automatic 100w duct heater Call our support team on

6 Mechanical Extract Ventilation (MEV) Units Provide constant low level ventilation through a centralised appliance, by extracting waste air from a dwelling and helping to prevent condensation and mould from developing. Mechanical Ventilation with Heat Recovery (MVHR) Units Incorporates supply and extract ventilation in one system. Warm, waste air is extracted from wet rooms via ducting through a highly efficient heat exchanger before being exhausted to the outside. Fresh incoming air is preheated via the exchanger and ducted into habitable rooms. MVHR is particularly effective in air tight properties where a build-up of condensation, mould and stale air can negatively impact the health of occupants. Whole house MEV units Single room MVHR units INF9050 INF9050H Will reduce Dwelling Emission Rates (DER) to secure additional SAP points Provides peace of mind that the unit s performance complies with current Building Regulations Flexible home owner control (3 speed options) Extracts 325 m³/h on Mountable above a void Central extract MEV system 3x125mm spigots with manually operated 3-speed controller (SAP Appendix Q listed) Central extract MEV system 3x125mm spigots with automatic humidity (SAP Appendix Q listed) HR100 HR100S HR100HS HR100LVS HR100LVHTS Ventilates a single room Provides balanced heat recovery ventilation Simple core-drill installation when wall mounted Heat recovery unit with remote Heat recovery unit continuous trickle with pull cord Heat recovery unit continuous trickle with humidity sensor and pull cord Heat recovery unit continuous trickle with pull cord, Heat recovery unit continuous trickle with humidity sensor, timer and pull cord, Whole house energy efficient MEV units Will reduce Dwelling Emission Rates (DER) to secure additional SAP points Provides peace of mind that the unit s performance complies with current Building Regulations Exceptionally compact (125mm deep) and lightweight (3.25kg), ideal for small ceiling void depths Ventilates a floor area of up to 275m² Easy and quick to install and maintain Distinct EPP casing reduces noise Extremely low Specific Fan Power down to 0.24 W/(l/s) High air flow performance up to 120 l/s In-line ports enable straightforward duct connection Flexible home owner control (3 speed options) INF9051 INF9051H Central extract MEV system 2x220/90 spigots with adjustable speed settings and remote (SAP Appendix Q listed) Central extract MEV system 2x220/90 spigots with adjustable speed settings and humidity sensor / remote (SAP Appendix Q listed) Whole house MVHR units INF9000 INF9000SW INF9001 Will reduce Dwelling Emission Rates (DER) to secure additional SAP points Performance complies with current Building Regulations Up to 91% heat exchange efficiency Simple to install weighs only 14kg (one man installation) Low Specific Fan Power down to 0.73W/(l/s) Easy to maintain through removable and washable filters (no need to dismantle unit) Mechanical ventilation unit with heat recovery with 3-speed manual controller - suitable for ventilating up to 180m 2 (SAP Appendix Q listed) Mechanical ventilation unit with heat recovery with 3-speed manual controller and summer / winter switch - suitable for ventilating up to 180m 2 (SAP Appendix Q listed) Mechanical ventilation unit with heat recovery with 3-speed manual controller - suitable for ventilating up to 90m 2 (void mounted) 6 Call our support team on

7 Remote controllers 1414 Fan speed controller M1007 Sensortronic Micro remote controller with humidity sensor and pull cord D1007 Sensortronic Digital remote controller with humidity sensor and pull cord UAX1007 Remote humidity sensor with timer and pull cord INF1007 Remote humidity sensor with timer for Infinity 9000 MVHR unit PIR INF1007 SB9000 DLVTX Remote passive infra red detector Remote humidity / timer controller for Infinity 9000 Remote switch box for multi-point switching for Infinity 9000 Standard transformer only Accessories General Accessories WS100 Wall sleeve 100mm - 275mm length WS150 Wall sleeve 150mm - 275mm length WP100/150 Wall fixing plate for 100mm and 150mm fans or grilles* FG100 Fixed grille 100mm* FG150 Fixed grille 150mm* GG100 Gravity grille 100mm* GG150 Gravity grille 150mm* WG100 Window kit for 100mm fans with gravity flaps WG150 Window kit for 150mm fans with gravity flaps WG100ES Window kit for 100mm electric-shutter fans with fixed grilles WG150ES Window kit for 150mm electric-shutter fans with fixed grilles BS100 Backdraught shutter 100mm BS125 Backdraught shutter 125mm BS150 Backdraught shutter 150mm BS100V Backdraught shutter slimline 100mm BS150V Backdraught shutter slimline 150mm CT100 Condensation trap 100mm CT125 Condensation trap 125mm CT150 Condensation trap 150mm RED100/125 Reducer 100mm - 125mm RED125/150 Reducer 125mm - 150mm HRWL Single-room heat recovery wall kit HRWW Single-room heat recovery window kit HRCE Single-room heat recovery ceiling kit Fire Protection FDA100 Fire damper 100mm FDA125 Fire damper 125mm FDA150 Fire damper 150mm FIRE100 Fire collar 100mm FIRE125 Fire collar 125mm FIRE150 Fire collar 150mm Flexible Ducting FD100 Flexible ducting 100mm - PVC - 3m length FD125 Flexible ducting 125mm - PVC - 3m length FD150 Flexible ducting 150mm - PVC - 3m length FD100A Flexible ducting 100mm - aluminium - 3m length FD125A Flexible ducting 125mm - aluminium - 3m length FD150A Flexible ducting 150mm - aluminium - 3m length FD100IN Flexible ducting 100mm - insulated - 3m length FD125IN Flexible ducting 125mm - insulated - 3m length FD150IN Flexible ducting 150mm - insulated - 3m length Weather Cowles CG100 Cowled grille 100mm with backdraught flap* CG150 Cowled grille 150mm with backdraught flap* CG100ES Cowled grille 100mm for continuous running or electric shutter fans* CG150ES Cowled grille 150mm for continuous running or electric shutter fans* CG100WW Cowled grille 100mm for windows in white CG150WW Cowled grille 150mm for windows in white IC100 Internal cowle 100mm for high-rise installations* IC150 Internal cowle 150mm for high-rise installations* IC100HRS Single-room heat recovery internal cowle 100mm for high-rise installations (with split-pipe)* Passive Ventilators CV100 Cosivent 100mm with adjustable shutter PV100 Passive vent 100mm for air-input PV150 Pasive vent 150mm for air-input TDR100 Tumble dryer vent kit 100mm *Comes in white, terracotta, brown and stone. Call our support team on

8 Ferrob Ventilation offers an extensive range of products and accessories to accommodate customers specifications, backed up by our comprehensive warranties. We give free advice and assistance with specifications and solutions. Our experienced technical department is always on hand to advise customers. All works are covered under the umbrella of the NICEIC and an NICEIC Minor Works Certificate is included with the completed paperwork back to the client. Ferrob Ventilation is a registered Part P installer to ensure that all electrical works are carried out to the highest standard. Ferrob Ventilation is a company registered in England and Wales with registered number Registered office: Broomhouse Lane, Edlington, Doncaster, DN12 1ES. We reserve the right to alter product specification without prior notice. Ferrob Ventilation Regency House Kingsclere Park Newbury, Berkshire RG20 4SW Tel: +44 (0) Fax: +44 (0) sales@ferrob.co.uk Web:

Polypipe Ventilation Specifiers Guide

Polypipe Ventilation Specifiers Guide Uniclass L75344 CI/SfB (57.5) X PVSB-2 May 215 Polypipe Ventilation Specifiers Guide Mechanical Ventilation with Heat Recovery Mechanical Extract Ventilation Intermittent Extract and Decentralised Mechanical

More information

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans CI/SfB (57.7) 1st Edition A new generation of Lo-Carbon continuous running fans Lo-Carbon Response/SELV dmev Unit A new generation of Lo-Carbon continuous running fans Looking towards the future Vent-Axia

More information

CI/SfB (57.7) 3rd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range.

CI/SfB (57.7) 3rd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range. CI/SfB (57.7) 3rd Edition WINNER2011 Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range. Lo-Carbon Centra Allowing you to help the environment

More information

MVHR & MEV VENTILATION GUIDE 2017

MVHR & MEV VENTILATION GUIDE 2017 MVHR & MEV VENTILATION GUIDE 2017 Mechanical Ventilation with Heat Recovery Mechanical Extract Ventilation Rigid and Semi-Rigid Duct Systems 1 All prices quoted exclude VAT and do not include trade discounts.

More information

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW NEW HRU ECO 3 RF ULTRA HIGH EFFICIENCY (95%) WHOLE HOUSE HEAT RECOVERY VENTILATION SYSTEM (MVHR) COMPLYING WITH SYSTEM 4 OF ADF2006 VENTILATION AIR CONDITIONING AIR CLEANING HEATING APPENDIX Q ELIGIBLE

More information

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications.

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications. Centra dmev Unit 62kg* carbon 80% energy E S P l i g i b l e Q P P E N D I X Part F compliant, System 3 IPX4 rated Continuous mechanical extract. Constant volume option. SP ppendix Q eligible - Low SFP

More information

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system Heat Recovery Ventilation Applicable to aircycle 1.1/1.2 (Ws - For Wall Mounting with In-built Control & Summer Bypass) Installation and Maintenance Instructions for the Installer. Please refer to the

More information

Domestic & Commercial Fans

Domestic & Commercial Fans Max. airflow l/s Axial Fan Centrifugal Fan Speed Controllable Reversible Airflow Page Number BF IF CF CBF BF 64 * 16 IF 64 * 16 EAF LV 23 * 169 ECF LV 31 * 169 CF 25 * 170 CBF 31 * 170 RVF 0 * * 171 BRAVO

More information

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation Residential Carbon Friendly Ventilation SAP Q Eligible ventilation Whole House Mechanical Ventilation - MVHR, MEV, dmev SAP Q ELIGIBLE PRODUCTS Energy Efficient Ventilation About Appendix Q SAP is the

More information

CI/SfB (57.7) 1st edition

CI/SfB (57.7) 1st edition CI/SfB (57.7) 1st edition By Appointment to H.M. The Queen Suppliers of Unit Ventilation Equipment Vent-Axia, Crawley, West Sussex VENT-AXIA CONTACT NUMBERS Free technical, installation and sales advice

More information

HRXD MVHR UNIT Mechanical Ventilation with Heat Recovery.

HRXD MVHR UNIT Mechanical Ventilation with Heat Recovery. HRXD MVHR UNIT 2018 Mechanical Ventilation with Heat Recovery 1 All prices quoted exclude VAT and do not include trade discounts. www.domusventilation.co.uk HRXD Range HRXD MVHR Mounts onto a wall in either

More information

Building Regulations 2010: What it means to you.

Building Regulations 2010: What it means to you. Building Regulations 2010: What it means to you. Where are we going? Ongoing changes to the ADF (Approved Document F) will bring about several differences to the way in which we use Ventilation in both

More information

CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV)

CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV) CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV) NUAIRE S PEDIGREE Proud to Build British Nuaire is a world leader in the design and manufacture of fans and ventilation systems. We

More information

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range & 300 Exceptionally low energy consumption High Efficiency, Low Profile Heat Recovery Range & 300 High Efficiency, Low Profile Heat Recovery Range High-efficiency, low profile MVHR units to deliver exceptionally

More information

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW NEW HRU ECO 3 RF ULTRA HIGH EFFICIENCY (95%) WHOLE HOUSE HEAT RECOVERY VENTILATION SYSTEM (MVHR) COMPLYING WITH SYSTEM 4 OF ADF2006 VENTILATION AIR CONDITIONING AIR CLEANING HEATING APPENDIX Q ELIGIBLE

More information

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units CI/SfB (57.7) 1st Edition Vent-Axia MVHR Units Vent-Axia Sentinel Kinetic Horizontal Range Lo-Carbon Sentinel Kinetic Horizontal MVHR Units Features & Benefits Manufactured in the UK Building Regulations

More information

Small Room Heat Recovery Ventilation

Small Room Heat Recovery Ventilation Small Room Heat Recovery Ventilation Ideal for smaller spaces that would benefit from heat recovery, such as staff rooms or offices Version 3.1 2 Breathing Buildings Small Room Heat Recovery 3 Small Room

More information

VENTILATION DESIGNED FOR CARE HOMES

VENTILATION DESIGNED FOR CARE HOMES CI/SfB (57) Uniclass Pr_65_67_29 October 2017................................ ............................................................................. Contents Ventilation designed for Care Homes

More information

ECO dmev Decentralised MEV

ECO dmev Decentralised MEV ECO dmev Decentralised MEV The ECO dmev has been designed and developed to offer the market a constant volume, continuously running decentralised extract fan to achieve the lowest power consumption, the

More information

NATURAL AND ENERGY-EFFICIENT VENTILATION SYSTEMS FOR DOMESTIC BUILDINGS

NATURAL AND ENERGY-EFFICIENT VENTILATION SYSTEMS FOR DOMESTIC BUILDINGS ...................................... CI/SfB (57) Uniclass L753 November 2007 NATURAL AND ENERGY-EFFICIENT VENTILATION SYSTEMS FOR DOMESTIC BUILDINGS...................................................................

More information

CI/SfB (57.7) 2nd edition. Lo-Carbon Quadra

CI/SfB (57.7) 2nd edition. Lo-Carbon Quadra CI/SfB (57.7) 2nd edition Lo-Carbon Quadra Vent-Axia Quadra An Evolution in Residential Ventilation, Designed especially for Social Housing One fan fits all Happy Installers The fan that fits anywhere,

More information

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Purge Ventilation Unit. Product Manual. ventilation systems TP625 EN Purge Ventilation Unit TP625 Product Manual ventilation systems Warnings, Safety Information and Guidance Important Information Important: read these instructions fully before the installation of this

More information

Specification. for Sapphire 100mm & 150mm Energy Efficient Axial Fans. Domus Ventilation

Specification. for Sapphire 100mm & 150mm Energy Efficient Axial Fans. Domus Ventilation Specification for Sapphire 100mm & 150mm Energy Efficient Axial Fans 1 Contents Page Scope of Works 3 Manufacturer 3 Product Range 3 Materials 3 Sizes 3 Performance Data 4 Accessories 4 Appendix A Range

More information

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions) NUAIRE MVHR (including opposite handed versions) ACHIEVES 100% DUTY IN BYPASS MODE and MRXBOXAB- ECO-LP1-OH are specically designed for apartment applications where space is a premium. The new MRXBOX95-LP1

More information

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger WHHR150DC SAP Q Eligible WHOLE HOUSE HEAT RECOVERY UNIT FEATURES Highly efficient, low energy solution to condensation and pollutant control Continuous ventilation in kitchen plus up to 5 additional wet

More information

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation NUAIRE MVHR and Opposite Handed version ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due to its intelligent

More information

SPECIFICATION GUIDE. Tel DOMUS VENTILATION

SPECIFICATION GUIDE. Tel DOMUS VENTILATION SPECIFICATION GUIDE Tel 3443 715 523 www.domusventilation.co.uk @DomusVent DOMUS VENTILATION Contents Introduction 3 Best Practice Guide 4 Indoor Air Quality 8 Mechanical Ventilation Products 9 DME Controls

More information

Lo-Carbon Sentinel Kinetic Horizontal

Lo-Carbon Sentinel Kinetic Horizontal Lo-Carbon Sentinel Kinetic Horizontal MVHR Unit Features & Benefits Manufactured in the UK Building Regulations ADF compliant Recognised in SAP Appendix Q Energy Savings Trust best practice compliant Up

More information

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

Itho Advance heat recovery ventilation unit. comfortable. indoor climate Itho Advance heat recovery ventilation unit comfortable indoor climate Advance heat recovery ventilation unit In order to make modern dwellings more energy efficient the insulation and air tightness has

More information

Centrifugal extract and condensation control fans

Centrifugal extract and condensation control fans Approvals: BEAB CE 3yr Guarantee Zone 1 Zone 2 The Premier range of pressure developing fans is designed specifically for domestic applications, where longer duct runs are required. Key features Type:

More information

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra Centrifugal Fan Lo-Carbon Quadra Centrifugal Fan Installation and Wiring Instructions Stock Ref. N Quadra TP Quadra TM Quadra HTP 439251A 439253A 439181A 220-240V~50Hz IPX4 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE NEW ECO RANGE MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) Mechanical Ventilation with Heat Recovery Proud to Build British u Nuaire is a world leader in the design and manufacture of fans and ventilation

More information

Apartment Ventilation. "Microbox" Continuous Mechanical Extract Units

Apartment Ventilation. Microbox Continuous Mechanical Extract Units Apartment Ventilation "Microbox" Continuous Mechanical Extract Units v e n t i l a t i o n IPX4 Vectaire Ltd is a member of: ; Fan Manufacturers Association; Smoke Control Association; Residential Ventilation

More information

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems energisava 300 & 400 High Efficiency Whole House Heat Recovery Systems Providing all year round good indoor

More information

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover Automatic & Manual Hand dryers for Commercial Applications 1.1kW Compact Eco Swift 409733 409734 Satin Stainless Steel 409735 Polished Stainless Steel Intelligent sensing, element auto switch off when

More information

PRODUCT CATALOGUE 2018

PRODUCT CATALOGUE 2018 PRODUCT CATALOGUE 2018 Leading home ventilation and central vacuum specialists www.bpcventilation.com CONTENTS About Us What is MVHR? Heat Recovery Units - 01 - Vent-Axia - 02 - Airflow - 03 - Xpelair

More information

LANDLORDS & LETTINGS VENTILATION SOLUTIONS

LANDLORDS & LETTINGS VENTILATION SOLUTIONS LANDLORDS & LETTINGS VENTILATION SOLUTIONS CREATING A HEALTHY INDOOR ENVIRONMENT CONTENTS INTRODUCTION... 3 WHY IS VENTILATION IMPORTANT?...4 CURE CONDENSATION FOR GOOD... 5 THE DRIMASTER RANGE... 6 SINGLE

More information

Centrif Duo & Centrif Duo Plus

Centrif Duo & Centrif Duo Plus Centrif Duo & Centrif Duo Plus Installation and Wiring Instructions Stock Ref. N Centrif Duo P 25 61 20D Centrif Duo T 25 62 20D Centrif Duo DP 25 63 20D Centrif Duo HTP 25 64 20D Centrif Duo Centrif Duo

More information

Lo-Carbon Quadra SELV

Lo-Carbon Quadra SELV Lo-Carbon Quadra SELV Installation and Wiring Instructions Stock Ref. N Quadra SVTP 442865 Quadra SVHTP 442866 Quadra SVTM 442867 Safety Extra Low Voltage IPX7 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO3 MRXBOX-ECO3 NUAIRE MVHR MRXBOX-ECO3 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

MRXBOXAB-ECO2 MRXBOX-ECO2

MRXBOXAB-ECO2 MRXBOX-ECO2 NUAIRE MVHR MRXBOX-ECO2 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) IMPROVING INDOOR AIR QUALITY IN NEW HOMES 1 NUAIRE S PEDIGREE Proud to Build British Nuaire is a world leader in the design and manufacture of fans and

More information

BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS

BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS ...................................... CI/SfB (57) Uniclass L753 July 2015 BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS................................................................... ...................................................................................

More information

Introducing the RetroVent

Introducing the RetroVent Fans For Life Introducing the RetroVent Features Benefits Made in the UK Flying the flag for UK manufacturing, lower carbon footprints and total control over quality Tubular heat recovery cell Designed

More information

HYBRID PLUS2 AIRCOOL VENTILATORS

HYBRID PLUS2 AIRCOOL VENTILATORS NEW PRODUCT CI/SfB (57.7) Xy Uniclass Ss_65_40_33_56 February 2018 HYBRID PLUS2 AIRCOOL VENTILATORS................................ ........................................................ HYBRID PLUS2

More information

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS. INSTALLATION/OPERATING INSTRUCTIONS FOR C100 & C100T Thank you for purchasing a quality Extractor fan from Greenbrook. Please read these instructions fully prior to initial use. Every effort has been made

More information

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit DC Heat Recovery Unit MVHR Wholehouse heat recovery unit Stock Ref. N DC Heat Recovery Unit MVHR 443423 Installation, Maintenance & Users Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

More information

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system Viewpoint August 2012 Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system Dr Sarah Price and Helen Brown Summary Mechanical Ventilation and Heat

More information

ventilation solutions

ventilation solutions ventilation solutions for apartments and communal residences Helping to create a relaxing, ventilation solutions comfortable environment Nuaire is the market leader in the design and manufacture of energy

More information

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions ELIX 1003 Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions 3 speed continuous running SAP Appendix Q Eligible 3 models: - standard - timer - humidity control for all

More information

BUILDING STANDARDS SUPPORTING GUIDANCE DOMESTIC VENTILATION

BUILDING STANDARDS SUPPORTING GUIDANCE DOMESTIC VENTILATION BUILDING STANDARDS SUPPORTING GUIDANCE DOMESTIC VENTILATION 2 ND EDITION 1 Contents 1. Purpose of this document 3 Page 2. Ventilation 4 3. Purpose provided ventilation 6 4. Natural ventilation- windows,

More information

VENTILATION AND HEAT RECOVERY

VENTILATION AND HEAT RECOVERY VENTILATION AND HEAT RECOVERY In last month s article we looked at the energy cost of ventilation. The cost of the heat lost when stale air is extracted is much greater than any energy used by fans. But

More information

Ventilation for Refurbishment Projects

Ventilation for Refurbishment Projects CI/SfB (57.7) 1st Edition Our commitment to quality and service runs right through the core of the business, and through our supply chain to you, our customers, Vent-Axia - the First Name in Ventilation.

More information

WHHR Midi & Midi Lite

WHHR Midi & Midi Lite WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page

More information

S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5

S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5 S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE The Quietest Extractors in the World in their Category Lp 26,5 db AXIAL FLOW FANS Series -1-1 16182 6376-2 -3 NEW Installation examples Axial fl

More information

Intelligent Air Solutions

Intelligent Air Solutions Uniclass L75 CI/SfB (57) X HRX-aQSB. May 06 Intelligent Air Solutions QUIET COMPACT EFFICIENT MANUFACTURED IN THE UK Applications Suitable applications Introducing Polypipe s new and highly efficient Silavent

More information

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM SOLAR PRE-HEAT VENTILATION SYSTEM SUNWARM USES SOLAR ENERGY TO REDUCE THE HEATING DEMAND OF THE HOME AS WELL AS PROVIDING A COMPLETE VENTILATION SOLUTION. 76 BENEFITS Sunwarm Air provides both a ventilation

More information

Ventilation Product range ADVANCE ECO 4 ECO 2

Ventilation Product range ADVANCE ECO 4 ECO 2 Product range ADVANCE ECO 4 ECO 2 Air, we breathe it without thinking. Keeping it that way in the modern, airtight homes calls for class-leading ventilation performance and you will find this with the

More information

low energy environmentally friendly economical residential ventilation with EC motors June 2015 Issue 5

low energy environmentally friendly economical residential ventilation with EC motors June 2015 Issue 5 v e n t i l a t i o n low energy environmentally friendly economical residential ventilation with EC motors June 2015 Issue 5 low energy, environmentally friendly, economical, low carbon Whole House Mechanical

More information

RESIDENTIAL VENTILATION DUCTING SOLUTIONS

RESIDENTIAL VENTILATION DUCTING SOLUTIONS RESIDENTIAL VENTILATION DUCTING SOLUTIONS NUAIRE S PEDIGREE ABOUT NUAIRE Nuaire have designed and manufactured innovative, quality products for home and overseas markets since 1963. The group has extensive

More information

i PSV WHOLE-HOUSE VENTILATION SYSTEM

i PSV WHOLE-HOUSE VENTILATION SYSTEM CI/SfB (57) Uniclass Ss_65_40_33_56 November 2017 i PSV WHOLE-HOUSE VENTILATION SYSTEM Humidity-sensitive wall ventilator Energy saver vent................................ HOW TRADITIONAL PASSIVE STACK

More information

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Model: Kair Whole House Ventilator Model Number: KHRVWH2000 Model: Kair Whole House Ventilator Model Number: KHRVWH2000 Installation, Maintenance Instructions and User Guide Unit 6 Chiltonian Industrial Estate 203 Manor Lane, Lee, London. SE12 0TX Tel: 08451 60

More information

Ventilation & Heat Recovery. The whole house system from OMNIE

Ventilation & Heat Recovery. The whole house system from OMNIE Ventilation & Heat Recovery The whole house system from OMNIE 2 Contents ABOUT OMNIE 4 The Whole house system 6 Why OMNIE Ventilation & Heat Recovery? 7 How does it work? PRODUCT 9 Comfo Air Q MVHR Unit

More information

7 YEAR. The DRIMASTEReco Range DRI-ECO-HC NUAIRE S PIV: HALL CONTROL

7 YEAR. The DRIMASTEReco Range DRI-ECO-HC NUAIRE S PIV: HALL CONTROL NUAIRE S PIV: HALL CONTROL The DRIMASTEReco Range The DRIMASTER-ECO range provides whole home ventilation using the Positive Input Ventilation principle, which introduces fresh filtered air into the dwelling

More information

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT NEW VORT PROMETEO HR 400 HEAT RECOVERY UNIT VENTILATION AIR CONDITIONING AIR CLEANING HEATING 2 VORT PROMETEO HR 400 (Code 11815) Quiet, Effective with a Thermal Efficiency up to 92 % Energy Saving Lowers

More information

The Sentinel Kinetic Horizontal Range

The Sentinel Kinetic Horizontal Range Lo-Carbon Sentinel Kinetic Horizontal Features & Benefits Manufactured in the UK Building Regulations DF compliant Recognised in SP PCDB Energy Savings Trust best practice compliant Up to 81% heat recovery

More information

Ventilation. Axial Fans Centrifugal Fans Low Voltage Fans Shower Fans Commercial Fans Flexible Ducting Fixing Kits External Grilles Hand Dryers

Ventilation. Axial Fans Centrifugal Fans Low Voltage Fans Shower Fans Commercial Fans Flexible Ducting Fixing Kits External Grilles Hand Dryers Ventilation xial Fans Centrifugal Fans Low Voltage Fans Shower Fans Commercial Fans Flexible ucting Fixing Kits xternal Grilles Hand ryers Telesales Hotline 01582 544 544 9 Ventilation T extractor fans

More information

The Glidevale range of Fresh wall

The Glidevale range of Fresh wall CI/SfB (57) Uniclass Pr_30_59_96 December 2017 The Glidevale range of Fresh wall ventilators has been specially designed to introduce fresh air into our homes in order to control condensation, and being

More information

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside MRXBOX95-WM1 (Standard Unit) MRXBOX95-WM1-OH (Opposite hand Unit) MRXBOX95AB-WM1 (Standard Unit) MRXBOX95AB-WM1-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for Wall Mounting

More information

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Commissioning Data: To be completed by the Commissioning Engineer. Refer to User/Homeowner Guide

More information

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside Installation and Maintenance MRXBOX95-WM1 (Standard Unit) MRXBOX95-WM1-OH (Opposite hand Unit) MRXBOX95AB-WM1 (Standard Unit) MRXBOX95AB-WM1-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat

More information

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT - WHOLE HOUSE HEAT RECOVERY UNIT 95% efficient, SAP Appendix Q compliant heat recovery unit.. 29 285 82 BENEFITS High efficiency 95% efficient, with DC motors using 5% less energy than traditional fans.

More information

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra Centrifugal Fan Lo-Carbon Quadra Centrifugal Fan Installation and Wiring Instructions Stock Ref. N Quadra TP Quadra TM Quadra HTP 439251A 439253A 439181A 220-240V~50Hz IPX4 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions Commissioning Data: To be completed by the Commissioning Engineer. Refer to User / Homeowner Guide also supplied.

More information

Installation and Maintenance

Installation and Maintenance MRXBOXAB-ECO4 (Standard Unit) MRXBOXAB-ECO4-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery and Heat Exchanger Bypass for Wall Mounting Installation and Maintenance The EMC Directive

More information

Installation and Maintenance

Installation and Maintenance MRXBOXAB-ECO4-SW (Standard Unit) MRXBOXAB-ECO4-OHSW (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery and Heat Exchanger Bypass for Wall Mounting The EMC Directive 014/30/EU The Low

More information

energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System

energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System energisava 200 High Efficiency Whole House Heat Recovery System Joining the high efficiency energisava

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. Silhouette Installation and Wiring Instructions Stock Ref. N 45 40 55B (100B) 44 51 61 (125B) 45 40 59B (150X) 45 40 56B (100T) 44 51 62 (125T) 45 40 60B (150XT) 45 40 57B (100HT) 44 51 63 (125HT) 45 40

More information

BATHROOM EXTRACT FANS SILENT-100 Series

BATHROOM EXTRACT FANS SILENT-100 Series SILENT-1 Series Range of axial extractors with airflow rates of 95 m 3 /h, for connection to 1 mm diameter circular ducting. Motor mounted on silent-elastic-blocks which absorb the vibrations and allow

More information

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Simply Silent Contour 4 (100mm) Axial Extraction Fan Simply Silent Contour 4 (100mm) Axial Extraction Fan Suitable for bathrooms, toilets, shower and utility rooms Controls humidity, odours and mould growth Sleek low-profile design, wall or ceiling mounting

More information

GUIDELINES FOR A CORRECT VENTILATION

GUIDELINES FOR A CORRECT VENTILATION CATALOGUE GUIDELINES FOR A CORRECT VENTILATION Selecting the correct fan Extraction is always made from humid/polluted premises: kitchens, laundries, toilets, bathrooms, bars... To choose the fan airflow

More information

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2 NUAIRE S MVHR Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2 Nuaire s First Fix and Acoustic Solution are designed to not only reduce noise but to improve the installation when wall or cupboard

More information

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

WHHR125DC Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use "WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor Installation, Operating and Maintenance Instructions domestic and commercial use Page 2 Contents Section Page Number Introduction 3 How

More information

FRESHVENT. Select a product. Home/Freshvent

FRESHVENT. Select a product. Home/Freshvent Home/Freshvent FRESHVENT Completely silent, all year round ventilation Complements existing ventilating fans Filtered, natural air without draughts Control of the indoor environment Helps prevent damaging

More information

Green Line CMX. Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions. Model: CMX

Green Line CMX. Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions. Model: CMX Green Line CMX Central Mechanical Extract Ventilation (cmev) appliance Installation and Operating Instructions Model: CMX These instructions must be given to the householder DO NOT SWITCH OFF THE UNIT

More information

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE NEW VORT PROMETEO HR 400 HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE VENTILATION AIR CONDITIONING AIR CLEANING HEATING 2 VORT PROMETEO HR 400 (Code 11815) Quiet, Effective Ventilation in Full Compliance with

More information

Air Flow Solutions. A Guide to Specifing and Installing Residential Ventilation

Air Flow Solutions. A Guide to Specifing and Installing Residential Ventilation Air Flow Solutions A Guide to Specifing and Installing Residential Ventilation Contents Section 1: Why we need to ventilate 4-5 Airtight Homes Condensation Carbon Emissions Mould Toxic Gases Noise Concept

More information

G Installation manual Solitude - dmev unit

G Installation manual Solitude - dmev unit G G Installation manual Solitude - dmev unit Read this manual carefully before using the product and keep it in a safe place for reference. This product was constructed up to standard and in compliance

More information

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans Installation and Maintenance IPX4* The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU 1.0 SAFETY INFORMATION

More information

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual 90000556/90000557 Issue 10 9/17 MODEL: DV72 R & L Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation:

More information

MRXBOX95-WH1 MECHANICAL VENTILATION WITH HEAT RECOVERY

MRXBOX95-WH1 MECHANICAL VENTILATION WITH HEAT RECOVERY MECHAICA VETIATIO WITH HEAT RECOVERY UP TO 95% EFFICIET, SAP APPEDIX Q RECOGISED. WA/CUPOARD MOUTIG DESIG FOR MEDIUM TO ARGE HOUSES & APARTMETS. 36 029 2085 8200 EEFITS is designed to provide optimised

More information

Technical Bulletin 005(B) Developed with Building Standards Scotland

Technical Bulletin 005(B) Developed with Building Standards Scotland Technical Bulletin 005(B) Developed with Building Standards Scotland Title: Gas cookers in internal kitchens - Ventilation requirements as applied to Scotland Date issued: 1 July 2015 Note: This version

More information

Installation and Maintenance

Installation and Maintenance 1.0 INTRODUCTION MRXBOXAB-ECO-LP1SW (Standard Unit) MRXBOXAB-ECO-LP1-OHSW (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The

More information

Ventilation and Hand Dryers

Ventilation and Hand Dryers Ventilation Product Catalogue 2018 Ventilation and Hand Dryers Ventilation Fans are attractively styled to blend with modern environments whatever the application, from kitchens and bathrooms to utility

More information

Installation and Maintenance

Installation and Maintenance 1.0 Introduction MRXBOX-ECO2 (Standard Unit) MRXBOX-ECO2-OH (Opposite hand Unit) MRXBOXAB-ECO2 (Standard Unit) MRXBOXAB-ECO2-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for

More information

Energy Efficient Air Distribution Systems

Energy Efficient Air Distribution Systems (57.7) X from Polypipe Ventilation Energy Efficient Air Distribution Systems VSPweb On-line Planner Providing Duct Systems for: Mechanical Ventilation with Heat Recovery Mechanical Extract Ventilation

More information

CI/SfB (57.5) November 2008

CI/SfB (57.5) November 2008 CI/SfB (57.5) climate systems November 2008 High-comfort, low-energy ventilation An energy efficient, fresh, clean and healthy climate - all year round Ubbink Heat Recovery Ventilation (HRV) systems provide

More information

HYBRID PLUS2 AIRCOOL VENTILATORS

HYBRID PLUS2 AIRCOOL VENTILATORS NEW PRODUCT CI/SfB (57.7) Xy Uniclass Ss_65_40_33_56 February 2018 HYBRID PLUS2 AIRCOOL VENTILATORS................................ ........................................................ HYBRID PLUS2

More information

Best Practice Guidance. Best Practice Guidance Positive Input Ventilation (PIV) System

Best Practice Guidance. Best Practice Guidance Positive Input Ventilation (PIV) System Best Practice Guidance Best Practice Guidance Positive Input Ventilation (PIV) System October 2017 1. INTRODUCTION 2. DEFINITIONS 3. CONCEPT AND BACKGROUND OF PIV 4. INSPECTION CONSIDERATIONS 5. OCCUPIER

More information

HRX-aQ Range. Mechanical Ventilation with Heat Recovery appliances. Installation and Operating Instructions

HRX-aQ Range. Mechanical Ventilation with Heat Recovery appliances. Installation and Operating Instructions HRX-aQ Range Mechanical Ventilation with Heat Recovery appliances Installation and Operating Instructions Models: AQH200-S, AQH200-B, AQH240-S, AQH240-B These instructions must be given to the householder

More information