QT MIXER HOBART HL200-1STD

Size: px
Start display at page:

Download "QT MIXER HOBART HL200-1STD"

Transcription

1 1B 1A walk-in condensers verify location with architect walk-in site conditions: basement under floor poured concrete on metal deck on steel bar joist of beams 1 1 LOT WALK-IN COOLER/FREEZER BALLY CUSTOM W/ FLOORS SEE FSE-7 1A 1 LOT COOLER REFRIGERATION BALLY CUSTOM 1B 1 LOT FREEZER REFRIGERATION BALLY CUSTOM 2 1 LOT WALK-IN SHELVING METRO METRO SEAL III 3 1 LOT STORAGE SHELVING METRO SUPER ERECTA BRITE QT MIXER HOBART HL200-1STD MEAT DRY STORAGE WALK-IN FREEZER ramp 34DR WALK-IN COOLER remote pull MIXER STAND HOBART MIXER-TABLE2 6 1 WORK TABLE UNIVERSAL STAINLESS 8-SL-SLS-42 CUSTOM DEPTH SHELF TSD WORK TABLE UNIVERSAL STAINLESS 6-SL-SLS WORK TABLE W/ SINK UNIVERSAL STAINLESS 7-SL-SLSB-30 SINK SB & MARINE EDGE 9 1 UNASSIGNED NUMBER 10 1 UNASSIGNED NUMBER 11 1 UNASSIGNED NUMBER 12 1 WALL SHELF UNIVERSAL STAINLESS WSD HAND SINK ADVANCE TABCO 7-PS LOT FIRE SUPPRESSION SYSTEM FIRE SYSTEMS OF MICHIGAN ANSUL - UL 300 W/ REMOTE PULL 15 1 LOT EXHAUST HOOD VENT TECH CUSTOM SEE MANUFACTURERS DWG FSE WATER FILTER - COMBI & STEAMER EVERPURE EV CONVECTION OVEN ALTO-SHAAM ASC-4G BELOW 18 1 COMBI OVEN ALTO-SHAAM CTP7-20G 19 1 STEAMER GROEN SSB-5GF W/ STAND 20 1 UNASSIGNED NUMBER 21 1 POT FILLER T & S BRASS B CHAR BROILER SOUTHB HDC EQUIPMENT STAND UNIVERSAL STAINLESS ES-SL-3036-S BURNER RANGE SOUTHB 4601DD ABOVE W/STACKING KIT FLOOR PLAN & SCHEDULE GRIDDLE SOUTHB HDG EQUIPMENT STAND UNIVERSAL STAINLESS ES-SL-3036-S W/ CASTERS 27 1 FRYER PITCO SG14T REACH-IN FREEZER TRUE FOOD SERVICE T-49F 29 1 WATER FILTER - ICE MAKER EVERPURE EV UNASSIGNED NUMBER HAND VEG UNASSIGNED NUMBER 32 1 ICE MAKER MANITOWOC ICE IY-0606A BIN B REACH-IN REFRIGERATOR TRUE FOOD SERVICE T WATER FILTER - BEVERAGES EVERPURE EV COFFEE MAKER BUNN-O-MATIC CRTF5 - BY VOR 36 1 JUICE DISPENSER BUNN-O-MATIC BY VOR 37 1 BEVERAGE COUNTER W/SINK LAROSA CUSTOM DUMP SINK SEE FSE CHEF'S LINE LAROSA CUSTOM SEE MANUFACTUERE'S DWG'S FSE UNASSIGNED NUMBER 40 1 UNASSIGNED NUMBER 41 1 UNASSIGNED NUMBER 42 1 UNASSIGNED NUMBER 43 1 UNASSIGNED NUMBER UNASSIGNED NUMBER HEAT LAMP HATCO GRAH V MT'D ON # HEAT LAMP HATCO GRAH V MT'D ON # UNASSIGNED NUMBER UNASSIGNED NUMBER 49 1 SOUP WELLS WELLS SS-10ULTDUCI V MD'T IN # UNASSIGNED NUMBER 51 1 UNASSIGNED NUMBER 52 1 UNASSIGNED NUMBER DRAWN BY: pll MICROWAVE ACP, INC. RFS12TS 54 1 LOT PRINTERS BY OTHERS 55 1 REACH-IN REFRIGERATOR TRUE FOOD SERVICE T-49 SCALE: 1/4" = 1'-0" WORK TABLE W/ SINK UNIVERSAL STAINLESS 7-SL-SLSB-30 SINK SB & MARINE EDGE 57 1 WALL SHELF UNIVERSAL STAINLESS WSD FOOD PROCESSOR ROBOT COUPE R2N ULTRA 59 1 SLICER HOBART SLICER STAND HOBART CUTTER-TABLE4 W/CASTERS 61 1 UNASSIGNED NUMBER 62 1 LOT CLEAN DISH SHELVING METRO METRO SEAL III WALL MT'D 63 1 CLEAN DISH SHELF METRO METRO SEAL III 64 1 THREE COMPARTMENT SINK UNIVERSAL STAINLESS 3SL1824-2D BUSSING CART CAMBRO BC SOILED DISHTABLE UNIVERSAL sdt-sl-8-rl W/ SCRAP SINK 67 1 SORTING SHELF UNIVERSAL DT0-11 WALL MT'D 68 1 PRE-RINSE FAUCET T & S BRASS B-0133-BC PARTIAL PLAN 69 1 WAREWASHER HOBART AM UNASSIGNED NUMBER 71 1 UNASSIGNED NUMBER 72 1 LOT DISH HOOD VENT TECH CUSTOM SEE MANUFACTUERES DWG FSE CLEAN DISHTABLE UNIVERSAL STAINLESS CDT-5-RL 74 1 JANITOR SINK BY OTHERS 75 1 LOT CLEAN SUPPLY STORAGE RACK METRO METRO SEAL III 76 1 EYE WASH SINK T & S BRASS EW-7360B FSE-1

2 walk-in condensers verify location with architect walk-in site conditions: basement under floor poured concrete on metal deck on steel bar joist of beams M1 M2 HO - FD GENERAL CONTRACTOR NOTE #1: general CONTRACTOR TO PROVIDE wall backing for all wall mounted shelving. verify height, depth and mounting requirements. GENERAL CONTRACTOR NOTE #2: M3 M4 M5 12" X 12" SWS GT (SEE MECHANICAL NOTE #2) FTFD if required, general contractor to provide a high temp back flow prevention devise on all equipment with a high temp water connection (coffee brewers, dishmachine etc.) M6 12" x 12" SWS (CAPABLE OF ACCOMMODATING 180+ DEGREE WATER) (SEE MECHANICAL NOTE #3) M14 M17 M18 M19 M21 M25 M22 M23 M24 M26 M51 M27 MEAT M15 M-3 M20 M-8 M-7 34DR M39 M38 M-5 M42 M-3 M41 VEG HAND M54 M55 M-6 M50 remote pull BUILDING GREASE TRAP VERIFY LOCATION WITH ARCHITECT M7 M8 M9 M10 M12 M13 M14 M15 M16 M17 M18 M19 M20 M21 M22 M23 M24 M25 M26 M27 M28 M29 M30 M31 M32 M33 M34 M35 M36 M37 M38 M39 M40 M41 M42 M43 M44 M45 M46 8" X 8" SWS 8" x 8" SWS (CAPABLE OF ACCOMMODATING 180+ DEGREE WATER) (SEE MECHANICAL NOTE #3) (4) 1/2" H & CW AND 1 1/2" W 1'-2" AFF BT HAND SINK ITEM #13 3/4" W BT FTFD (M 5) INSTALL P-TRAP LINE OUTSIDE COOLER EVAPORATOR COIL ITEM #1A 3/4" W BT FTFD (M 5) INSTALL P-TRAP IN LINE OUTSIDE FREEZER EVAPORATOR COIL ITEM #1B 3/4" H & CW 1'-2" AFF BT WORK TABLE WITH SINK ITEM #8 (2) 1 1/2" W BT SWS (M 3) WORK TABLE WITH SINK ITEM #8 3/4" CW 4'-6" AFF BT WATER FILTER INLET ITEM #16 3/4" G 50,000 BTU 1'-6" AFF BT CONVECTION ITEM #17 3/4" CW BRANCH FROM (M16) (TREATED WATER INLET) BT COMBI OVEN ITEM #18 3/4" CW (UNTREATED WATER INLET) 1'-2" AFF BT COMBI OVEN ITEM #18 1 1/2" W BT SWS (M 8) COMBI-OVEN ITEM #18 3/4" G 85,000 BTU 1'-6" AFF BT COMBI-OVEN ITEM #18 3/4" CW BRANCH FROM (M16) BT STEAMER ITEM #19 1/2" CW 1'-2" AFF BT STEAMER DRAIN TEMPERING KIT ITEM #19 1/2" G 62,000 BTU 1'-6" AFF BT STEAMER ITEM #19 1 1/2" W BT SWS (M 8) STEAMER ITEM #19 3/4" G 120,000 BTU 1'-6" AFF BT CHAR BROILER ITEM #22 3/4" G 420,000 BTU 1'-6" AFF BT 10 BURNER RANGE ITEM #24 3/4" G 90,000 BTU 1'-6" AFF BT GRIDDLE ITEM #25 3/4" G 100,000 BTU 1'-6" AFF BT FRYER ITEM #27 3/4" CW 6'-2" AFF BT WATER FILTER INLET ITEM #29 (SEE DETAIL #4) 1/2" CW (3/8" CONNECTION) BRANCH FROM (M30) WATER FILTER OUTLET BT ICE MACHINE ITEM #32 (2) 3/4" W BT SWS (M 7) ICE MAKER & ICE BIN ITEM #32 3/4" CW 6'-2" AFF BT WATER FILTER INLET ITEM #34 (SEE DETAIL #4) 1/2" CW (1/4" CONNECTION) BRANCH FROM (M33) BT COFFEE BREWER ITEM #35 (VERIFY BY OTHERS) 1/2" CW (3/8" CONNECTION) BRANCH FROM (M33) BT JUICE DISPENSER ITEM #36 (VERIFY BY OTHERS) 1/2" H & CW 1'-2" AFF BT BEVERAGE COUNTER DUMP SINK ITEM #37 1 1/2" W BT SWS (M 7) BEVERAGE COUNTER DUMP SINK ITEM #37 1/2" CW SU BT HOT FOOD TABLE ITEM #38 1" W BT SWS (M 7) HOT FOOD TABLE ITEM #38 (2) 1" W BT SWS (M 7) SOUP WELLS ITEM #49 3/4" H & CW 1'-2" AFF BT WORKTABLE WITH SINK ITEM #56 1 1/2" W BT SWS (M 7) WORKTABLE WITH SINK ITEM #56 3/4" H & CW 1'-2" AFF BT THREE COMPARTMENT SINK ITEM #64 1 1/2" W BT GT (M 4) SEE (MECHANICAL NOTE #2) THREE COMPARTMENT SINK ITEM #64 (2) 1 1/2" W BT SWS (M 3) THREE COMPARTMENT SINK ITEM #64 1 1/2" W BT GT (M 4) (SEE MECHANICAL NOTE #2) SOILED DISHTABLE SCRAP SINK ITEM #66 NOTE: ALL WATERING TEMPERING VALVES REQUIRED TO BE FURNISHED BY MECHANICAL CONTRACTOR HOT WATER REQUIREMENTS ARE CALCULATED AT 80% EFFICIENCY MC = MECHANICAL ENGINEER 1. ME TO VERIFY REQUIREMENTS FOR EQUIPMENT NOT SUPPLIED BY F.S.E.C. 2. ME TO VERIFY IF A GREASE TRAP (G.T.) IS REQUIRED. IF REQUIRED, MOUNT GREASE TRAP FLUSH WITH FINISH FLOOR, UPSTREAM FROM FLOOR DRAIN. PC TO SIZE G.T. AND LOCATE IN AN ACCESSIBLE AREA. PC TO ALSO VERIFY IF LOCAL CODES REQUIRE ALL SINK BOWLS TO BRANCH TO (BT) A GREASE TRAP (GT) IN LIEU OF A SAFE WASTE SINK (SWS). 3. ME TO VERIFY IF DRAIN WATER TEMPERING KIT IS REQUIRED FOR FOOD SERVICE EQUIPMENT THAT HAS A DISCHARGE ABOVE 140 F. IF REQUIRED, A 1/2" COLD WATER LINE WILL BE NECESSARY FOR DRAIN QUINCH TEMPERING KIT. 4. ME TO COORDINATE WITH F.S.E.C. AND INSTALL AUTOMATIC GAS SHUT OFF VALVE (FURNISHED BT FSEC) IN A 12" REMOVABLE SECTION OF PIPE OF THE MAIN FOOD SERVICE EQUIPMENT GAS SUPPLY LINE AS CLOSE AS POSSIBLE TO THE COOKING EQUIPMENT. THE AUTOMATIC GAS SHUT OFF VALVE IS TO BE IN AN ACCESSIBLE AREA ABOVE A GYPSUM CEILING. GENERAL CONTRACTOR IS TO PROVIDE ACCESS PANELS AS REQUIRED FOR THE AUTOMATIC GAS SHUT OFF VALVE. (NOT APPROVED IF CEILING AREA BEING USED AS A RETURN AIR PLENUM) TO MEET ALL CODE REQUIREMENTS. 5. ME TO VERIFY ALL VENTILATION AND DUCT WORK THAT IS REQUIRED. 6. ALL UTILITIES SHOWN WITH SYMBOLS CENTERED ON WALL TO BE CONCEALED IN WALLS. DO NOT STUB OUT OF FLOORS AND RUN EXPOSED ON WALLS. 7. UTILITIES, SWITCHES, ETC. NOT SHOWN ON THIS PLAN FOR EXHAUST FANS, MAKE-UP AIR UNITS, ETC. TO BE VERIFIED WITH ARCHITECTURAL DRAWINGS. 8. OWNER & CONTRACTORS SHALL VERIFY ALL EXISTING DIMENSIONS, EQUIPMENT SIZES, AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL EXISTING EQUIPMENT SHOWN ON THE DRAWINGS ARE USED AS GUIDELINES FROM INFORMATION PROVIDED AND MUST BE VERIFIED. 10. MECHANICAL CODE MAY REQUIRE A SOLIDS INTERCEPTOR IN ALL CASES WHERE A GARBAGE DISPOSER IS INSTALLED. ME TO VERIFY. -THIS DRAWING SHOWS ONLY THOSE CONNECTIONS REQUIRED TO PROPERLY INSTALL THE FOOD SERVICE EQUIPMENT FURNISHED BY THE FOOD SERVICE EQUIPMENT CONTRACTOR (FSEC) OR DIRECTLY CONNECTED TO THE OPERATION OF THE FOOD AND BEVERAGE FACILITY. IT DOES NOT SHOW RESTROOM, LIGHT FIXTURES. OR HEATING CONNECTIONS, ETC. AS THESE ARE TO BE FOUND ON THE ARCHITECTURAL PLANS, FURNISHED BY OTHERS. SIZES SHOWN FOR CUSTOMER AND EMPLOYEE RESTROOMS TO BE VERIFIED BY OTHER CONTRACTORS AND INSTALLED TO MEET ALL CURRENT LOCAL, STATE AND FEDERAL CODES. -THESE CONNECTIONS SHOULD BE STUBBED IN AND ALLOWANCES MUST BE MADE FOR VALVES, TRAPS, L'S, T'S ETC. FURNISHED BY OTHER CONTRACTORS. -IF THE SPOT IS MARKED "BT" (BRANCH TO) THE SPOT INDICATES WHERE THE STUB-IN SHOULD TERMINATE OR BE CAPPED SO IT CAN BE BRANCHED TO CONNECTION POINT IN FIXTURE AT TIME OF FINAL CONNECTION. -THE EQUIPMENT FURNISHED BY THE FSEC SHALL BE DELIVERED, UNCRATED, ERECTED AND SET IN PLACE READY TO RECEIVE ALL ELECTRICAL AND MECHANICAL CONNECTIONS BY OTHER CONTRACTORS UNLESS OTHERWISE QUOTED TO THE OWNER. -THE MECHANICAL AND ELECTRICAL CONTRACTORS SHALL FURNISH ALL NECESSARY LABOR AND MATERIALS INCLUDING SWITCHES, PLUG-IN RECEPTACLES, WIRING, PIG-TAILS, PLUGS, CORDS, DISCONNECT SWITCHES, INTER-WIRING, FLOOR DRAINS, FLOOR SINKS, SAFE WASTE SINKS, GREASE TRAPS, STEAM TRAPS, PRESSURE REDUCING VALVES, SHUT-OFF VALVES, PRESSURE TYPE WATER VACUUM BREAKERS, PIPING AND ALL FITTINGS NECESSARY FOR THE OPERATION OF THE EQUIPMENT SHOWN ON THE DRAWINGS AT NO COST TO THE FSEC. -Any existing exhaust hood system(s) marked as existing and/or reused are shown for reference purposes only. It is the responsibility of the owner and respective contractors to evaluate the existing hood system(s) and verify that all components and material are in approved working condition per manufacture specification for correct operation while complying with all national, state and local codes and ordinances. -Any existing equipment that is marked as existing and/or reused are shown for references purposes only. All utility information and dimensions are the responsibility of the owner and respective contractors and must be verified prior to the reinstall of any of existing and/or reused equipment. All existing and/or reused equipment and their utilities must be installed and comply with manufacture specification for correct operation while following all national, state and local codes and ordinances. MECHANICAL / GENERAL CONTRACTOR NOTE: REGARDING AUTOMATIC FIRE PROTECTION SYSTEMS FOR KITCHEN COOKING EQUIPMENT. COORDINATE WITH CONTRACTOR PLUMBING CONTRACTOR TO INSTALL IN MAIN FOOD SERVICE EQUIPMENT GAS SUPPLY LINES A MECHANICAL SHUT OFF VALVE FURNISHED BY FOOD SERVICE EQUIPMENT CONTRACTOR IN AN AREA AS CLOSE AS POSSIBLE TO THE COOKING EQUIPMENT. MECHANICAL REQUIREMENTS M28 M29 M-7 M40 M47 M48 M49 M50 1/2" H & CW 1'-2" AFF BT PRE-RINSE ITEM #68 3/4" HW (MIN. 110 DEGREE WATER) 1'-2" AFF BT DISHWASHER (WITH BUILT-IN BOOSTER HEATER) ITEM #69 1/2" CW 1'-2" AFF BT DISH MACHINE DRAIN TEMPERING KIT ITEM #69 2" W BT SWS (M 6) DISH MACHINE ITEM #69 GENERAL CONTRACTOR TO PROVIDE ACCESS PANELS AS REQUIRED IF MECHANICAL GAS VALVE TO BE LOCATED ABOVE A GYPSUM CEILING. (NOT APPROVED IF CEILING AREA BEING USED AS A RETURN AIR PLENUM.) TO MEET ALL CODE REQUIREMENTS M51 1/2" CW 4'-6" AFF BT POT FILLER ITEM #21 M30 M56 M-7 M52 1/2" H & CW 3'-0" AFF BT JANITORS SINK ITEM #74 (VERIFY BY OTHERS) M53 2" W JANITOR SINK ITEM #74 (VERIFY BY OTHERS) M54 1/2" CW 1'-2" AFF BT EYE WASH ITEM #76 M55 1 1/4" W 1'-2" AFF eye wash ITEM #76 M56 1 1/2" W BT SWS (M 7) BEVERAGE COUNTER TROUGH ITEM #37 MECHANICAL NOTE #1: MECHANICAL CODE MAY REQUIRE A SOLIDS INTERCEPTOR IN ALL CASES WHERE A GARBAGE DISPOSER IS INSTALLED. MECHANICAL ENGINEER TO VERIFY. HW CW W IW HO FD FTFD HOT WATER COLD WATER WASTE - DIRECT CONNECTION INDIRECT WASTE DRAIN HUB OUTLET FLOOR DRAIN FUNNEL TYPE FLOOR DRAIN SCALE: 1/4" = 1'-0" DRAIN BOARD SAN. RINSE WASH DRAIN BOARD FINISHED FLOOR PARTIAL PLAN THE INSTALLATION SHOWN ON THIS DRAWING IS FOR THE EXPRESS PURPOSE OF PROVIDING INSTALLATION GUIDELINES ONLY. THE FINAL INSTALLATION APPROVAL IS THE RESPONSIBILITY OF THE SYSTEM MECHANICAL CONTRACTOR. DRAINED THOUGH AIR GAP: ICE MACHINETORAGE BINS, FOOD PREPARATION SINKS, THREE COMPARTMENT SINKS, BEVERAGE DISPENSERS, DIPPERWELLS, STEAMERS, KETTLES, REFRIGERATION CONDENSATE DRAIN LINES, DISHWASHERS/GLASS WASHERS. UNDER BAR SINKS, UNDERBAR DRAIN BOARDS, POTATO PEELER, CHINESE RANGE, POWER WASHER, STEAM TABLES/BAIN-MARIES, COFFEE/TEA BREWERS, ESPRESSO MACHINE, COMBI-STYLE OVEN, KETTLE, RETHERMALIZER, BLAST CHILLER, PASTA COOKER WATER SOFTENER, POP GUN HOLDER, NON-EVAPORATING AND WATER COOLED EQUIPMENT cold water in (main supply) INLET OUTLET FLUSH WATER FILTER NOT TO SCALE coffee brewer SWS GT G ECC DR SPO LIGHT SW SS SR SU A.F.F. D.F.A. BTU SAFE WASTE SINK 1" A.F.F. GREASE TRAP GAS ELECTRICAL CONDUIT CONNECTION DUPLEX RECEPTACLE SPECIAL PLUG OUTLET LIGHT SWITCH STEAM SUPPLY STEAM RETURN STUB UP ABOVE FINISHED FLOOR DROP FROM ABOVE BRITISH THERMAL UNIT CUBIC FEET PER MIN. 2" 2" 2" BT KW BRANCH TO KILOWATT AIR GAP 3" SWS W/ SEDIMENT BUCKET GREASE TRAP 3" typical three COMPARTMENT SINK DETAIL W/GREASE TRAP DETAIL #2 TYPICAL INSTALLATION FOR CASTER-MOUNTED EQUIPMENT USING DORMONT QUICK DISCONNECT KIT MODEL #1675KIT2S48 (REGULATOR & ELBOWS ARE NOT INCLUDED IN GAS CONNECTOR KIT SAFE WASTE SINK - TYPICAL NO SCALE TYPICAL water filter DETAIL juice machine HP PH AMP mca GC MC PC EC FSEC HORSE POWER PHASE AMPHERE maximum capacity amps GENERAL CONTRACTOR MECHANICAL CONTRACTOR PLUMBING CONTRACTOR ELECTRICAL CONTRACTOR CONTRACTOR FSE-2

3 walk-in condensers verify location with architect walk-in site conditions: basement under floor poured concrete on metal deck on steel bar joist of beams E1 E2 E3 E4 E5 DR 120V-1 PHASE 20.0 AMP 4'-2" AFF CONVENIENCE OUTLETS DR 120V-1 PHASE 20.0 AMP 1'-2" AFF CONVENIENCE OUTLETS (2) ECC 120V-1 PHASE AMP EACH COOLER & FREEZER DFA BT DOOR HEATERS, LIGHTS & PRESSURE RELIEF ON WALK-IN COOLER/FREEZER ITEM #1 ECC 120V 1-PHASE 4.0 AMP (15 AMP CIRCUIT) DFA BT COOLER EVAPORATOR COIL ITEM #1A ECC V-1 PHASE 10.3 AMP (15 AMP CIRCUIT) DFA BT FREEZER EVAPORATOR COIL ITEM #1B (EC TO PROVIDE ELECTRICAL DEFROST CONTROL -THIS DRAWING SHOWS ONLY THOSE CONNECTIONS REQUIRED TO PROPERLY INSTALL THE FOOD SERVICE EQUIPMENT FURNISHED BY THE FOOD SERVICE EQUIPMENT CONTRACTOR (FSEC) OR DIRECTLY CONNECTED TO THE OPERATION OF THE FOOD AND BEVERAGE FACILITY. IT DOES NOT SHOW RESTROOM, LIGHT FIXTURES. OR HEATING CONNECTIONS, ETC. AS THESE ARE TO BE FOUND ON THE ARCHITECTURAL PLANS, FURNISHED BY OTHERS. SIZES SHOWN FOR CUSTOMER AND EMPLOYEE RESTROOMS TO BE VERIFIED BY OTHER CONTRACTORS AND INSTALLED TO MEET ALL CURRENT LOCAL, STATE AND FEDERAL CODES. E6 WIRING BETWEEN CONDENSING UNIT AND EVAPORATOR COIL & FURNISH POWER FOR FREEZER COIL DRAIN LINE HEAT TAPE ECC V-1 PHASE 9.2 AMP (15 AMP CIRCUIT) 7/8 HP BT OUT DOOR COOLER CONDENSING UNIT ITEM #1A -THESE CONNECTIONS SHOULD BE STUBBED IN AND ALLOWANCES MUST BE MADE FOR VALVES, TRAPS, L'S, T'S ETC. FURNISHED BY OTHER CONTRACTORS. E-1 E-1 E14 MEAT E-2 E13 E-9 34DR E-3 E31 HAND remote pull E-2 E7 E8 E9 E10 E11 E12 E13 E14 E15 E16 E17 E18 E19 E20 E21 E22 E23 E24 E25 E26 E27 E28 E29 E30 E31 ECC V-1 PHASE 19.9 AMP (30 AMP CIRCUIT) 2.5 HP BT OUTDOOR FREEZER CONDENSING UNIT ITEM #1B ECC JUNCTION BOX 120V-1 PHASE 8.0 AMP 1/2 HP SU BT CONVENIENCE OUTLET MT'D ON WORK TABLE (ITEM #6) FOR MIXER ITEM #4 (2) ECC JUNCTION BOX 120V-1 PHASE 20.0AMP SU BT CONVENIENCE OUTLET MT'D ON WORK TABLE ITEM #6 & 7 ECC JUNCTION BOX DFA BT AUTOMATIC FIRE SUPPRESSION SYSTEM ITEM #14 REMOTE FIRE PULL ITEM #14 (SEE ELECTRICAL NOTE #2 & FIRE SYSTEM DETAIL DRAWING) (VERIFY LOCATION) ECC 120V-1 PHASE 300 WATT DFA BT JUNCTION BOX FOR HOOD LIGHTS ITEM #15 ECC 120V-1 PHASE 7.5 AMP (20 MCA) 0.9 KW BT CONVECTION OVEN CONTROLS ITEM #17 (NEMA 5-15 P) (SEE ELECTRICAL NOTE #2) ECC 120V-1 PHASE 6.8 AMP (20 MCA DEDICATED).84 KW BT COMBI-OVEN CONTROLS ITEM #18 (SEE ELECTRICAL NOTE #2) EMPTY CONDUIT FOR DATA LINES ITEM #54 (VERIFY BY OTHERS) DR 120V-1 PHASE 5.8 AMP (15 AMP DECEICATED CIRECUIT) 1/3 HP 1'-2"AFF BT REACH-IN REFRIGERATOR ITEM #55 (NEMA 5-15P) ECC 120V-1 PHASE 15.0 AMP 1'-2" AFF BT STEAMER CONTROLS ITEM #19 (SEE ELECTRICAL NOTE #2) DR 120V-1 PHASE 5.0 AMP 1'-2" AFF BT FRYER ITEM #27 (SEE ELECTRICAL NOTE #2) DR 120V-1 PHASE 11.0 AMP (15 AMP DECEICATED CIRECUIT) 1'-2" AFF BT REACH-IN FREEZER ITEM #28 (NEMA 5-15P) ECC 208V-1 PHASE 11.1 (15 MCA) AMP 5'-2" AFF BT ICE MAKER ITEM #32 DR 120V-1 PHASE 5.8 AMP (15 AMP DECEICATED CIRECUIT) 1/3 HP 1'-2"AFF BT REACH-IN REFRIGERATOR ITEM #33 (NEMA 5-15P) ECC 120/208V-1 PHASE 19.2 AMP 4050 WATTS 4'-2" AFF BT COFFEE BREWER ITEM #35 (VERIFY BY OTHERS) DR 120V-1 PHASE 9.5 AMP 4'-2" AFF BT JUICE DISPENSER ITEM #36 (NEMA 5-15P) (VERIFY BY OTHERS) ECC 120/208V-1 PHASE AMP SU BT CHEF'S LINE BREAKER PANEL ITEM #38 (REFER TO MANUFACTURER DRAWING FSE 6) DR 120V-1 PHASE 7.0 AMP 1 HP 4'-2" AFF BT FOOD PROCESSOR ITEM #58 (NEMA 5-15P) DR 120V-1 PHASE 5.0 AMP 1/2 HP 1'-2" AFF BT SLICER ITEM #59 -IF THE SPOT IS MARKED "BT" (BRANCH TO) THE SPOT INDICATES WHERE THE STUB-IN SHOULD TERMINATE OR BE CAPPED SO IT CAN BE BRANCHED TO CONNECTION POINT IN FIXTURE AT TIME OF FINAL CONNECTION. -THE EQUIPMENT FURNISHED BY THE FSEC SHALL BE DELIVERED, UNCRATED, ERECTED AND SET IN PLACE READY TO RECEIVE ALL ELECTRICAL AND MECHANICAL CONNECTIONS BY OTHER CONTRACTORS UNLESS OTHERWISE QUOTED TO THE OWNER. -THE MECHANICAL AND ELECTRICAL CONTRACTORS SHALL FURNISH ALL NECESSARY LABOR AND MATERIALS INCLUDING SWITCHES, PLUG-IN RECEPTACLES, WIRING, PIG-TAILS, PLUGS, CORDS, DISCONNECT SWITCHES, INTER-WIRING, FLOOR DRAINS, FLOOR SINKS, SAFE WASTE SINKS, GREASE TRAPS, STEAM TRAPS, PRESSURE REDUCING VALVES, SHUT-OFF VALVES, PRESSURE TYPE WATER VACUUM BREAKERS, PIPING AND ALL FITTINGS NECESSARY FOR THE OPERATION OF THE EQUIPMENT SHOWN ON THE DRAWINGS AT NO COST TO THE FSEC. -Any existing exhaust hood system(s) marked as existing and/or reused are shown for reference purposes only. It is the responsibility of the owner and respective contractors to evaluate the existing hood system(s) and verify that all components and material are in approved working condition per manufacture specification for correct operation while complying with all national, state and local codes and ordinances. -Any existing equipment that is marked as existing and/or reused are shown for references purposes only. All utility information and dimensions are the responsibility of the owner and respective contractors and must be verified prior to the reinstall of any of existing and/or reused equipment. All existing and/or reused equipment and their utilities must be installed and comply with manufacture specification for correct operation while following all national, state and local codes and ordinances. ELECTRICAL REQUIREMENTS E15 VEG E32 ECC 208V-3 PHASE 45.4 AMP (60 MCA) 1'-6" AFF BT DISHWASHER WITH BUILT-IN BOOSTER HEATER ITEM #69 E30 E33 DR 120V-1 PHASE 5.0 AMP 5'-2" AFF BT DETERGENT DISPENSER FOR ITEM #69 (VERIFY BY OTHERS) E17 E17 E29 E-1 E18 E33 GENERAL CONTRACTOR NOTE #1: general CONTRACTOR TO PROVIDE wall backing for all wall mounted shelving. verify height, depth and mounting requirements. HW HOT WATER CW COLD WATER E23 W IW WASTE - DIRECT CONNECTION INDIRECT WASTE DRAIN HO HUB OUTLET E24 FD FTFD SWS FLOOR DRAIN FUNNEL TYPE FLOOR DRAIN SAFE WASTE SINK 1" A.F.F. DATE: VERIFY HEIGHT AND EXACT REQUIREMENT WITH LOCAL AUTHORITY. ADA REQUIREMENTS MAY APPLY. DETAIL #1 ANSUL FIRE SYSTEM REMOTE PULL STATION DETAIL GT G ECC DR SPO GREASE TRAP GAS ELECTRICAL CONDUIT CONNECTION DUPLEX RECEPTACLE SPECIAL PLUG OUTLET SCALE: 1/4" = 1'-0" LIGHT LIGHT SW SS SWITCH STEAM SUPPLY EC= ELECTRICAL CONTRACTOR SR STEAM RETURN PARTIAL PLAN 1. EC TO VERIFY REQUIREMENTS FOR EQUIPMENT NOT SUPPLIED BY FSEC. 2. EC TO DETERMINE WIRING DIAGRAM FOR FIRE SUPPRESSION SYSTEM ACCORDING TO OWNER AND ALL APPLICABLE CODE REQUIREMENTS. IN REGARD TO THE AUTOMATIC INTERRUPTION OF GAS AND ELECTRIC POWER SUPPLIED TO COOKING EQUIPMENT, ELECTRICAL OUTLETS, HOOD LIGHTS, EXHAUST SUPPLY FANS, TRIPPING OF BUILDING ALARM SYSTEMS, ECT... TO BE THE RESPONSIBILITY OF EC. VERIFY ALL REQUIREMENTS WITH THE MECHANICAL CONTRACTOR (MC). SU A.F.F. D.F.A. BTU STUB UP ABOVE FINISHED FLOOR DROP FROM ABOVE BRITISH THERMAL UNIT CUBIC FEET PER MIN. 3. ALL EXHAUST FANS, MAKE-UP AIR UNITS, AIR TRANSFER FANS, ETC., ARE TO BE ELECTRICALLY INTERLOCKED. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ALL NECESSARY STARTERS, RELAYS, SWITCHES, DISCONNECTS, ETC, AS MAY BE REQUIRED. THIS PLAN DOES NOT SHOW POWER REQUIREMENT OR ON/OFF SWITCHES FOR EXHAUST SYSTEMS. 4. ALL ABOVE FINISH FLOOR (AFF) ELECTRICAL HEIGHTS ARE CALLED OUT FROM THE CENTER OF THE BOX. BT KW HP PH BRANCH TO KILOWATT HORSE POWER PHASE 5. SOME STATES ELECTRICAL CODES REQUIRE THE USE OF A GFCI RECEPTACLE ON THE COOKING LINE, PLEASE VERIFY IF THIS IS NEEDED. IF THIS RECEPTACLE IS REQUIRED THE USE OF A " PASS AND SEYMOUR", CAT. NO W 115VOLT 20.0 AMP GFCI DUPLEX RECEPTACLE IS RECOMMED. IF A LESSER QUALITY GFCI BREAKER IS USED PROBLEMS WITH START UP AMP LOAD DRAW MAY OCCUR. AMP mca GC AMPHERE maximum capacity amps GENERAL CONTRACTOR UTILITIES, SWITCHES, ETC. NOT SHOWN ON THIS PLAN FOR EXHAUST FANS, MAKE-UP AIR UNITS, ETC. TO BE VERIFIED WITH ARCHITECTURAL DRAWINGS. MC PC EC FSEC MECHANICAL CONTRACTOR PLUMBING CONTRACTOR ELECTRICAL CONTRACTOR CONTRACTOR FSE-3

4 BAFFLE FILTER CANOPY HOOD, WALL STYLE, EXHAUST ONLY WITH DOUBLE WALL FRONT. KITCHEN VENTILATION HOOD(S) SHALL BE OF THE TYPE 1, EXHAUST ONLY WALL CANOPY SUITABLE FOR ALL TYPES OF COOKING APPLICATIONS. THE HOOD(S) SHALL BE U.L. 710 LISTED WITHOUT FIRE DAMPER. MAKE-UP AIR SHALL BE INDEPENTLY PROVIDED. THE HOOD SHALL BE CONSTRUCTED OF A MINIMUM OF 18 GAUGE 304 STAINLESS STEEL WHERE EXPOSED. THE HOOD(S) SHALL BE CONSTRUCTED USING THE STANDING SEAM METHOD FOR OPTIMUM STRENGTH. AN INTEGRAL 3 INCH AIR SPACE IS PROVIDED TO MEET NFPA 96 CLEARANCE REQUIREMENTS AGAINST LIMITED COMBUSTIBLE WALLS. ALL SEAMS, JOINTS AND PENETRATIONS OF THE HOOD ENCLOSURE SHALL BE WELDED AND/OR LIQUID TIGHT. LIGHTER MATERIAL GAUGES, ALTERNATIVE MATERIAL TYPES AND FINISHES ARE NOT ACCEPTABLE. THE HOOD(S) SHALL INCLUDE A FILTER HOUSING CONSTRUCTED OF THE SAME MATERIAL AS THE HOOD. THE FILTERS SHALL BE STAINLESS STEEL BAFFLE TYPE, U.L CLASSIFIED, AND IN SUFFICIENT NUMBER AND SIZES TO ENSURE OPTIMUM PERFORMANCE. THE FILTER HOUSING SHALL TERMINATE IN A PITCHED, FULL LENGTH CONCEALED GREASE TROUGH WHICH SHALL DRAIN INTO A REMOVABLE GREASE CONTAINER. VAPOR PROOF, U.L. LISTED INCANDESCENT LIGHT FIXTURES SHALL BE PRE-WIRED TO A JUNCTION BOX LOCATED AT THE TOP OF HOOD FOR FIELD CONNECTION. WIRING SHALL CONFORM TO THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE (NFPA #70 - LATEST EDITION). THE CANOPY HOOD(S) SHALL BE CONSTRUCTED IN ACCORDANCE WITH NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) BULLETIN #96, INTERNATIONAL MECHANICAL CODE (IMC), UNIFORM MECHANICAL CODE (UMC), AND BEAR THE NATIONAL SANITATION FOUNDATION (NSF) SEAL OF APPROVAL. THE HOOD MANUFACTURER SHALL PROVIDE, ON REQUEST, THE NECESSARY DATA THAT CONFIRMS COMPLIANCE WITH THE CODE AUTHORITIES LISTED ABOVE. HOOD ITEM NUMBER HOOD LENGTH (INCHES) HOOD WIDTH (INCHES) HOOD WEIGHT (LBS) EXHAUST RATE (LIN. FT.) EXHAUST SIZE (INCHES) L-R x F-B VELOCITY (F.P.M) NET FILTER AREA (SQ. FT.) VELOCITY THRU FILTERS (F.P.M.) EXHAUST STATIC PRESSURE AT COLLAR TEMPERED AIR CURTAIN AIR CURTAIN DUCT SIZE (INCHES) L-R x F-B (2) 1250 (2) 11x (2) 625 (2) 18x (2) 1250 (2) 11x (2) 625 (2) 18x REAR INTEGRAL AIR SPACE AIR CURTAIN VELOCITY (F.P.M) STATIC PRESSURE AT AIR CURTAIN COLLAR (INCHES) VENTILATION REQUIREMENTS 14.0 GENERAL DO NOT SCALE DRAWINGS, USE DIMENSIONS AS INDICATED. IF QUESTIONS SHOULD ARISE, CLARIFY WITH VENT-TECH, INC. PRIOR TO RELEASING FOR MANUFACTURING. 2. IT IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO OBTAIN ALL PERMITS AND APPROVALS FROM ALL STATE AND LOCAL OFFICIALS PRIOR TO PROCEEDING WITH INSTALLATION. THESE DRAWINGS ARE TO SERVE AS BASIC DESIGN ONLY AND ANY STATE OR LOCAL ORDINANCE WHICH IS MORE RESTRICTIVE SHALL PREVAIL. 3. IT IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO CHECK BUILDING ACCESS AND FIELD CONDITIONS TO ALLOW FOR ADEQUATE CLEARANCES FOR THE EQUIPMENT TO BE BROUGHT IN AND INSTALLED. 4. VENT-TECH, INC. SHALL NOT BE RESPONSIBLE FOR IMPROPER EXHAUST OR MAKE-UP AIR DUE TO CHANGES IN STATIC PRESSURE OR AIR VOLUMES OTHER THAN THOSE AS SPECIFICALLY DETAILED. 5. AIR INTAKES MUST BE NO CLOSER THAN 10 FEET FROM ANY EXHAUST OR VENT OUTLET. HOOD15-1 PLAN VIEW HOOD15-1 PLAN VIEW STAINLESS STEEL TOP ENCLOSURE FROM TOP OF HOOD TO CEILING AT FRONT AND BOTH S PERFORATED AIR CURTAIN UL LISTED INCANDESCENT LIGHT FIXTURE UL LISTED STAINLESS STEEL BAFFLE FILTERS 3" REAR STANDOFF 6. MUST BE CONSTRUCTED FROM A MINIMUM OF 16 GAUGE LIQUID-TIGHT WELDED STEEL FITTED TIGHTLY INTO HOOD COLLAR AND CONTINUOUSLY WELDED TO HOOD. DUCT CLEAN OUTS SHALL BE PROVIDED AT EVERY CHANGE IN DIRECTION. INSTALLING CONTRACTOR SHALL VERIFY ANY REQUIREMENTS FOR INSULATION OF THE. EXHAUST FAN(S) SHALL EXT A MINIMUM OF 40 INCHES ABOVE ROOF SURFACE AND BE PROPERLY FLASHED TO ADJOINING MATERIAL. 7. SUPPLY DUCTWORK SHALL BE FABRICATED IN ACCORDANCE WITH THE LATEST SMACNA HVAC DUCT CONSTRUCTION STANDARD (METAL AND FLEXIBLE) AND SHALL BE EXTERNALLY INSULATED AND PROVIDED WITH VOLUME CONTROL DAMPERS AT EACH DISCHARGE GRILL. 8. ALL EXHAUST FANS, MAKE-UP AIR UNITS, AIR TRANSFER FANS, ETC.,ARE TO BE ELECTRICALLY INTERLOCKED. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ALL NECESSARY STARTERS, RELAYS, SWITCHES, ETC., AS REQUIRED. VERIFY CEILING HEIGHT 80.0 ABOVE FINISHED FLOOR 80" HIGH STAINLESS STEEL WALL PANEL AT REAR WALL REMOVABLE GREASE CUP W/ CONCEALED GREASE TROUGH SCALE: NONE 9. VERIFY ALL STRUCTURAL LOADS WITH ARCHITECT OF RECORD. 10. THESE DRAWINGS ARE TO SERVE AS A BASIC DESIGN ONLY AND ANY STATE OR LOCAL ORDINANCE WHICH IS MORE RESTRICTIVE SHALL PREVAIL. HOOD15-1 ELEVATION VIEW HOOD15-1 ELEVATION VIEW HOOD15 SECTION VIEW 11. IT IS THE RESPONSIBILITY OF THE OWNER/ARCHITECT TO ENSURE THE HOOD CLEARANCE FROM COMBUSTIBLES (AND NON OR LIMITED COMBUSTIBLES) IS IN COMPLIANCE WITH THE LATEST EDITION OF THE NATIONAL FIRE PROTECTION ASSOCIATION BULLETIN # HOOD CONSTRUCTION SHALL BE IN ACCORDANCE WITH 2012 MMC, 2012 MBC STATE BUILDING CODE, NFPA, NSF. CONSTRUCTION SHALL BE 18 GAUGE MIN. STAINLESS STEEL WHERE VISIBLE, NON-VISIBLE SECTIONS SHALL BE 18 GAUGE ALUMINIZED STL. OR 18 GAUGE ST. STL. ALL EXTERIOR SEAMS TO BE WELDED LIQUID TIGHT. 13. ROOF SERVICE PLATFORM(S), GUARD RAIL(S), AND ACCESS TO THEM SHALL BE PROVIDED IN ACCORDANCE WITH MMC 2012 SEC AND SUPPLY DUCT KEY ALL VENT TECH INC. HOODS MEET ONE OR MORE OF THE FOLLOWING U.L.-710, BOCA, NSF, ICBO, STATE OF MICHIGAN, SBCCI, NFPA 96, MMC INTERNATIONAL CODE (MI MECH 2012) FROM COMBUSTIBLES: COMBUSTIBLE SURFACE REDUCTION TO 7" AS FOLLOWS - 24 GA.MINIMUM UNPAINTED METAL (0.024) SPACED 1" OFF THE COMBUSTIBLE ASSEMBLY. IF INSTALLING A VENTILATION EXHAUST SYSTEM INTO AN AREA WHICH HAS CERTAIN STANDARDS OR CODES OTHER THAN THOSE NORMALLY ACCEPTED IN THE FOOD SERVICE INDUSTRY (NSF, UL, ETC) VENT TECH INC. MUST BE ADVISED OF THESE SPECIFICATIONS IN DETAIL BEFORE FABRICATION OF THE EQUIPMENT BEGINS. FAILURE TO ADVISE VENT TECH INC. OF SPECIFIC REQUIREMENTS COULD RESULT IN THE JOB BEING DELAYED, ADDITIONAL COSTS, OR BOTH. NFPA #96 CLEARANCES FROM COMBUSTIBLES: SURFACE COMBUSTIBLE LIMITED-COMBUSTIBLE NONCOMBUSTIBLE CLEARANCE 3" INSULATED 3" UN-INSULATED 0" REQUIRED 3" UN-INSULATED CLEARANCE PROVIDED STANDARD. IF 3" INSULATED CLEARANCE IS REQUIRED PER CHART, THEARCHITECT/OWNER SHALL NOTIFY VENT TECH INC. OF REQUIREMENT AND SHALL BE RESPONSIBLE THAT PROPER CLEARANCES ARE MAINTAINED PER CODES EASTLAND ROSEVILLE, MI PHONE: (800) 557-VENT (800) FAX: (586) VTOFFICE@VENT-TECH.COM FSE-4

5 SINGLE SHELL EXHAUST ONLY TYPE 2 CANOPY. THE HOOD SHALL BE CONSTRUCTED OF ALL STAINLESS STEEL. HOOD SHALL HAVE A PERIMETER GUTTER WITH A DRAIN LOCATED IN CORNER AND A STAINLESS STEEL NIPPLE. HOOD SHALL ALSO CONTAIN A STAINLESS STEEL PERFORATED DUCT PROTECTOR. HOOD ITEM NUMBER HOOD LENGTH (INCHES) HOOD WIDTH (INCHES) HOOD WEIGHT (LBS) EXHAUST RATE (LIN. FT.) EXHAUST SIZE (INCHES) L-R x F-B VELOCITY (F.P.M) (1) EXHAUST STATIC PRESSURE AT COLLAR COVER (MESH FILTER) INSTALLATION DETAIL HOOD TOP (INSIDE) EXHAUST COLLAR ING FILTER FRAME (MOUNTED ON HOOD TOP) MESH FILTER CONDENSATE DRAIN 1/2 in. NPT 21.0 DIA VENTILATION REQUIREMENTS 60.0 GENERAL HOOD 72 PLAN VIEW 1. DO NOT SCALE DRAWINGS, USE DIMENSIONS AS INDICATED. IF QUESTIONS SHOULD ARISE, CLARIFY WITH VENT-TECH, INC. PRIOR TO RELEASING FOR MANUFACTURING. 2. IT IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO OBTAIN ALL PERMITS AND APPROVALS FROM ALL STATE AND LOCAL OFFICIALS PRIOR TO PROCEEDING WITH INSTALLATION. THESE DRAWINGS ARE TO SERVE AS BASIC DESIGN ONLY AND ANY STATE OR LOCAL ORDINANCE WHICH IS MORE RESTRICTIVE SHALL PREVAIL. 3. IT IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO CHECK BUILDING ACCESS AND FIELD CONDITIONS TO ALLOW FOR ADEQUATE CLEARANCES FOR THE EQUIPMENT TO BE BROUGHT IN AND INSTALLED. 4. VENT-TECH, INC. SHALL NOT BE RESPONSIBLE FOR IMPROPER EXHAUST OR MAKE-UP AIR DUE TO CHANGES IN STATIC PRESSURE OR AIR VOLUMES OTHER THAN THOSE AS SPECIFICALLY DETAILED. STAINLESS STEEL TOP ENCLOSURE FROM TOP OF HOOD TO CEILING AT FRONT AND BOTH S AIR INTAKES MUST BE NO CLOSER THAN 10 FEET FROM ANY EXHAUST OR VENT OUTLET. 6. MUST BE CONSTRUCTED FROM A MINIMUM OF 16 GAUGE LIQUID-TIGHT WELDED STEEL FITTED TIGHTLY INTO HOOD COLLAR AND CONTINUOUSLY WELDED TO HOOD. DUCT CLEAN OUTS SHALL BE PROVIDED AT EVERY CHANGE IN DIRECTION. INSTALLING CONTRACTOR SHALL VERIFY ANY REQUIREMENTS FOR INSULATION OF THE. EXHAUST FAN(S) SHALL EXT A MINIMUM OF 40 INCHES ABOVE ROOF SURFACE AND BE PROPERLY FLASHED TO ADJOINING MATERIAL. VERIFY CEILING HEIGHT 80.0 ABOVE FINISHED FLOOR CONDENSATE GUTTER CONDENSATE DRAIN SCALE: NONE 7. SUPPLY DUCTWORK SHALL BE FABRICATED IN ACCORDANCE WITH THE LATEST SMACNA HVAC DUCT CONSTRUCTION STANDARD (METAL AND FLEXIBLE) AND SHALL BE EXTERNALLY INSULATED AND PROVIDED WITH VOLUME CONTROL DAMPERS AT EACH DISCHARGE GRILL. 8. ALL EXHAUST FANS, MAKE-UP AIR UNITS, AIR TRANSFER FANS, ETC.,ARE TO BE ELECTRICALLY INTERLOCKED. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ALL NECESSARY STARTERS, RELAYS, SWITCHES, ETC., AS REQUIRED. 9. VERIFY ALL STRUCTURAL LOADS WITH ARCHITECT OF RECORD. 10. THESE DRAWINGS ARE TO SERVE AS A BASIC DESIGN ONLY AND ANY STATE OR LOCAL ORDINANCE WHICH IS MORE RESTRICTIVE SHALL PREVAIL. HOOD 72 ELEVATION VIEW HOOD 72 SECTION VIEW 11. IT IS THE RESPONSIBILITY OF THE OWNER/ARCHITECT TO ENSURE THE HOOD CLEARANCE FROM COMBUSTIBLES (AND NON OR LIMITED COMBUSTIBLES) IS IN COMPLIANCE WITH THE LATEST EDITION OF THE NATIONAL FIRE PROTECTION ASSOCIATION BULLETIN # HOOD CONSTRUCTION SHALL BE IN ACCORDANCE WITH 2012 MMC, 2012 MBC STATE BUILDING CODE, NFPA, NSF. CONSTRUCTION SHALL BE 18 GAUGE MIN. STAINLESS STEEL WHERE VISIBLE, NON-VISIBLE SECTIONS SHALL BE 18 GAUGE ALUMINIZED STL. OR 18 GAUGE ST. STL. ALL EXTERIOR SEAMS TO BE WELDED LIQUID TIGHT. 13. ROOF SERVICE PLATFORM(S), GUARD RAIL(S), AND ACCESS TO THEM SHALL BE PROVIDED IN ACCORDANCE WITH MMC 2012 SEC AND SUPPLY DUCT KEY ALL VENT TECH INC. HOODS MEET ONE OR MORE OF THE FOLLOWING U.L.-710, BOCA, NSF, ICBO, STATE OF MICHIGAN, SBCCI, NFPA 96, MMC INTERNATIONAL CODE (MI MECH 2012) FROM COMBUSTIBLES: COMBUSTIBLE SURFACE REDUCTION TO 7" AS FOLLOWS - 24 GA.MINIMUM UNPAINTED METAL (0.024) SPACED 1" OFF THE COMBUSTIBLE ASSEMBLY. IF INSTALLING A VENTILATION EXHAUST SYSTEM INTO AN AREA WHICH HAS CERTAIN STANDARDS OR CODES OTHER THAN THOSE NORMALLY ACCEPTED IN THE FOOD SERVICE INDUSTRY (NSF, UL, ETC) VENT TECH INC. MUST BE ADVISED OF THESE SPECIFICATIONS IN DETAIL BEFORE FABRICATION OF THE EQUIPMENT BEGINS. FAILURE TO ADVISE VENT TECH INC. OF SPECIFIC REQUIREMENTS COULD RESULT IN THE JOB BEING DELAYED, ADDITIONAL COSTS, OR BOTH. NFPA #96 CLEARANCES FROM COMBUSTIBLES: SURFACE COMBUSTIBLE LIMITED-COMBUSTIBLE NONCOMBUSTIBLE CLEARANCE 3" INSULATED 3" UN-INSULATED 0" REQUIRED 3" UN-INSULATED CLEARANCE PROVIDED STANDARD. IF 3" INSULATED CLEARANCE IS REQUIRED PER CHART, THEARCHITECT/OWNER SHALL NOTIFY VENT TECH INC. OF REQUIREMENT AND SHALL BE RESPONSIBLE THAT PROPER CLEARANCES ARE MAINTAINED PER CODES EASTLAND ROSEVILLE, MI PHONE: (800) 557-VENT (800) FAX: (586) VTOFFICE@VENT-TECH.COM FSE-5

6 36" 208V HEAT LAMP B/O INSTALLED BY LaROSA 150AMP 208/240V SINGLE PHASE W/ MAIN LUG. 42" 208V HEAT LAMP B/O INSTALLED BY LaROSA 36" 208V HEAT LAMP B/O INSTALLED BY LaROSA (3) DEDICATED GFI DUPLEX 5-20-R 20A 120V PNL DRY larosa CHEF'S LINE DETAILS (2) INSULATED 11qt SOUP WELLS 120V HARDWIRED TO J-BOX 62" x 17" x 1/2" WHITE BOARD 30" x 10 1/2" x 1/2" WHITE BOARD 50" X 32" DP. SELF CONTAINED FREEZER WORK TOP. *INCLUDES SELF-CLOSING DOORS R-404A REFRIGERANT 115V/ 60 1, 9AMP W/ COND. EVAP. 62" X 32" DP. SELF CONTAINED PREP TABLE W/ RAISED RAILS TO HOLD (8) 1/3-SIZE PANS, PANS NOT INCL.*INCLUDES SELF-CLOSING DOORS R-134A REFRIGERANT 115V/ 60 1, 11AMP W/ COND. EVAP. 30" X 32" DP. HOT FOOD TABLE, ELEC. WET/DRY (2) INGS W/ INDIVIDUAL CONTROLS V, 10AMP TOTAL, (1) LINE HARDWIRED TO J-BOX W/ DRAINS MANIFOLDED *INCLUDES SWIVEL FILL FAUCET 72" X 32" DP. SELF CONTAINED REFRIGERATED WORK TOP. *INCLUDES SELF-CLOSING DOORS R-134A REFRIGERANT 115V/ 60 1, 11AMP W/ COND. EVAP. 214"x35"x18" dp. DOUBLE OVERSHELF SCALE: none FRZ PLATE SHELF FRZ REF REF REF REF REF MODEL: CUSTOM-CT SERIAL#: CT-DM-16 TYPE: CCI 17'-10" CHEFS COUNTER SECT. # 1 OF 7 LA ROSA ITEM # FILER AVE. DETROIT, MI MODEL # (QTY) DESCRIPTION VOL PH KW FLA L L PANEL HOUSING UTILITY CABINET MAIN LUG, 150 AMP SERVICE, 120/208V 60Hz 1PH SINGLE PHASE 60 Hz AC OF 7 1 L FRZ BASE OF 7 2 L REF'G BASE OF 7 3 L (2) HOT FOOD WELLS OF 7 4 L REF'G BASE OF 7 5 L (2) WELLS SOUP WRMS OF 7 7 L UTILITY CABINET L D OVERSHELF ASSEMBLY R (1) PRINTERS EQUIPMENT BUILT PER 5-20-R (1) PRINTERS R (1) MICROWAVE R GRAH-42 HATCO GRAH GRAH-36 HATCO GRAH GRAH-36 HATCO GRAH TOTALS: R FSE-6

7 larosa beverage counter detail 9"x14"x10" dp. HAND SINK 36" TROUGH MARINE EDGE STR REMOVABLE RISER DATE: 929/15 SCALE: 1/2" = 1'-0" PTD EQUIPMENT BUILT PER R FSE-7

8 BALLY WALK-IN COOLER/FREEZER DETAILS DATE: 9/29/15 SCALE: 1/2" = 1'-0" FSE-8

SCALE 1 INCH = 20 FEET C1.0

SCALE 1 INCH = 20 FEET C1.0 SCALE INCH = 20 FEET C.0 E Q U I P M E N T S C H E D U L E E Q U I P M E N T S C H E D U L E Item No Qty Description WALKIN RECEIVING FREEZER Furnished By: Item No Qty Description 04 COMBI OVEN /

More information

LABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY

LABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY STAFF USE ONLY Thurston County Resource Stewardship 2000 Lakeridge Dr. S.W. Olympia, WA 98502 (360)786-5490 / (360)754-2939 (Fax) TDD Line (360) 754-2933 Email: permit@co.thurston.wa.us www.co.thurston.wa.us/permitting

More information

DK02 1 ELECTRIC CAN OPENER 59 ITEM NO

DK02 1 ELECTRIC CAN OPENER 59 ITEM NO 63 62 76 60 61 EXISTING SCHEDULE DK01 1 TABLE DK02 1 ELECTRIC CAN OPENER 59 DK03 1 SLICER DK04 4 MOBILE INGREDIENT BIN DK05 1 MOBILE ENCLOSED TRAY RACK DK06 1 TABLE W/ DRAWER 77 58 53 53 DK07 1 MOBILE

More information

Food Service Establishment Plan Review Form

Food Service Establishment Plan Review Form CITY OF PARK RIDGE 505 BUTLER PLACE PARK RIDGE, IL 60068 TEL: 847/ 318-5291 FAX: 847/ 318-6411 TDD:847/ 318-5252 URL:http://www.parkridge.us Food Service Establishment Plan Review Form THE FOLLOWING INFORMATION

More information

Low Wall Back Shelf Exhaust Canopy

Low Wall Back Shelf Exhaust Canopy ITEM NO. 710 Powerline Road Suite H Deerfield Beach, FL 33442 (954) 570-9860 (800) 322-8730 FAX (954) 570-9865 Low Wall Back Shelf Exhaust Canopy Model LW APPLICATION Wall mounted canopy style ventilator

More information

Specifications 7/25/2012

Specifications 7/25/2012 Item 1 - MERCHANDISER, OPEN (1 REQ'D) Project Aspen Art Museum-Cafe From Jeff Katz (303) 440-4142 RPI Industries Model SCRFC3648R Bravo Air Screen Display Case, 36" L x 48" H, self-contained refrig., front

More information

900 N. Via Piemonte Ontario, CA

900 N. Via Piemonte Ontario, CA 2 3 L 8 5'-0" 6'-1" 5'-0" 4'-0" 2'-0" D.5 6" 9'-9" K 2 1 2 " 5'-0" 2'-0" 1'-2" 8" 4 4.3 7'-0" C.6 1'-8 1 2 " 7'-0" 8" 10'-6" 5'-0" 8" 6" 6'-6" 6'-3" PLUMBING SCOPE OF WORK - DRAINS 7'-3" 6'-8" KEC TO PROVIDE:

More information

Canning Shed/Facility Equipment Specifications

Canning Shed/Facility Equipment Specifications Canning Shed/Facility Equipment Specifications Item Qty Description 1 1 ea WALK IN COOLER Fast Trak Indoor One Compartment Walk In, 8' x 8' x 7' 7" H, compartments, cooler with smooth aluminum interior

More information

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS (630) 620-5750 Fax: (630) 629-2374 www.villageoflombard.org COMMERCIAL HOOD & DUCT SYSTEM PLAN REVIEW REQUIREMENTS International

More information

Food Establishment Plan Review Worksheet

Food Establishment Plan Review Worksheet Food Establishment Plan Review Worksheet To be completed by the operator and submitted to the local health department Establishment Information Name: Address: City, State, Zip:- 1 Pages 6-10 ask structural

More information

FOOD ESTABLISHMENT CONSTRUCTION GUIDE Revised December 19, 2011 Reviewed January 10, 2014

FOOD ESTABLISHMENT CONSTRUCTION GUIDE Revised December 19, 2011 Reviewed January 10, 2014 FOOD ESTABLISHMENT CONSTRUCTION GUIDE Revised December 19, 2011 Reviewed January 10, 2014 This construction guide is to be used in conjunction with the Oklahoma Food Service Establishment Regulations (OAC

More information

Food Service Plan Review Information

Food Service Plan Review Information Food Service Plan Review Information New or remodeled food preparation facilities, and those changing ownership, must undergo a plan review process prior to a health permit being issued. The purpose of

More information

Michigan Department of Agriculture and Rural Development

Michigan Department of Agriculture and Rural Development Michigan Department of Agriculture and Rural Development Fixed Food Establishment Plan Review Worksheet To be completed by the operator and submitted to the local health department or the Michigan Department

More information

FRESH FROM THE KITCHEN FRESH FROM THE KITCHEN

FRESH FROM THE KITCHEN FRESH FROM THE KITCHEN PLUMBING SCOPE OF WORK - DRAINS KEC TO PROVIDE: - ALL TWIST WASTE VALVES & BASKET DRAINS, AS REFLECTED ON EQUIPMENT SCHEDULE, - PIPE CONDENSATE DRAIN FOR WALK IN COOLER WITH 3/4" COPPER TUBING, WITH NECESSARY

More information

New Food Service Plan Review Checklist

New Food Service Plan Review Checklist New Food Service Plan Review Checklist The following items should be completed before you return your application. Read Starting a Food Service Brochure to help you in the process. Confirm whether property

More information

Structural Guidelines. Food Service Establishments. Retail Food Stores

Structural Guidelines. Food Service Establishments. Retail Food Stores Structural Guidelines for Food Service Establishments and Retail Food Stores Jefferson County Department of Health Food & Lodging Protection Division 1 Before construction or remodeling of a food service

More information

MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS PH: (361)

MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS PH: (361) C US FILE#:MH48178 MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS 78401 PH: (361)884-9800 WWW.JEANSRESTAURANTSUPPLY.COM UL Standard for Safety for Exhaust Hoods for

More information

FT1000S BASE FLIGHT-TYPE DISHWASHER

FT1000S BASE FLIGHT-TYPE DISHWASHER Item # Quantity C.S.I. Section 11400 FLIGHT-TYPE DISHER STANDARD FEATURES Pumped rinse system (pressure gauge not required) Water usage 58 gph Digital controls with machine diagnostics Low temperature

More information

Dear Concessionaire,

Dear Concessionaire, Dear Concessionaire, In order to provide a comprehensive review & inspection of the Vendor application please review the following as guidance to a complete application and preparedness for inspection.

More information

SECTION COMMERCIAL-KITCHEN HOODS

SECTION COMMERCIAL-KITCHEN HOODS SECTION 23 38 13 COMMERCIAL-KITCHEN HOODS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Delete other items or paragraphs in the section that are not applicable and renumber

More information

FRESNO COUNTY HUMAN SERVICES SYSTEM ENVIRONMENTAL HEALTH SYSTEM P.O. Box Fresno, CA Telephone (209)

FRESNO COUNTY HUMAN SERVICES SYSTEM ENVIRONMENTAL HEALTH SYSTEM P.O. Box Fresno, CA Telephone (209) FRESNO COUNTY HUMAN SERVICES SYSTEM ENVIRONMENTAL HEALTH SYSTEM P.O. Box 11867 Fresno, CA 93775 Telephone (209) 445-3392 CONSTRUCTION REQUIREMENTS FOR RETAIL FOOD ESTABLISHMENTS BEFORE CONSTRUCTING, ENLARGING,

More information

All food service facilities must be equipped with the following items for the pre-opening inspection:

All food service facilities must be equipped with the following items for the pre-opening inspection: DEPARTMENT OF HEALTH FOOD SERVICE FACILITY Pre-Opening Checklist This checklist is provided as a guide to prepare for the pre-opening inspection of a newly constructed, remodeled or a change-of-ownership

More information

DEMO - Bevles - BEVLES PASS THRU - HCSS34W4. USED - Berkel - BERKEL SLICER $595

DEMO - Bevles - BEVLES PASS THRU - HCSS34W4. USED - Berkel - BERKEL SLICER $595 DEMO - Bevles - BEVLES PASS THRU - HCSS34W4 $895 BEVLES PASS THEU HOLDING CABINE, UNDERCOUNTER TYPE, 208 VOLT, 1 PHASE USED - Berkel - BERKEL SLICER - 909 $595 BERKEL SLICING MACHINE, 12'' BLADE, 115VOLT

More information

SECTION CUSTOM FABRICATED FOODSERVICE EQUIPMENT

SECTION CUSTOM FABRICATED FOODSERVICE EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 40 11 CUSTOM FABRICATED FOODSERVICE EQUIPMENT SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Delete other items or paragraphs in

More information

Standard Features. Performance/Capacities

Standard Features. Performance/Capacities TSC-66 Traditional Power/Connections Approximate Total Load AMPS 208V / 60HZ / 3PH 51.8 208V / 60HZ / 1PH 88.3 230V / 60HZ / 3PH 47.8 230V / 60HZ / 1PH 81.5 460V / 60HZ / 3PH 23.9 Booster Heater Options

More information

Restaurant for Sale. Sur th Ave. E. Seattle, WA PROPERTY FEATURES: Capitol Hill

Restaurant for Sale. Sur th Ave. E. Seattle, WA PROPERTY FEATURES: Capitol Hill Restaurant for Sale Capitol Hill 340 15th Ave. E. Seattle, WA 9122 PROPERTY FEATURES: Excellent 15th Ave. location in the heart of one of Capitol Hill s favorite retail/ restaurant districts Fully built-out

More information

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER 701 S Ridge Avenue, Troy, OH 45374 Item # Quantity WITH BLOWER DRYER FLIGHT-TYPE DISHER C.S.I. Section 11400 STANDARD FEATURES Pumped rinse system (pressure gauge not required) Water usage 58 gph Digital

More information

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER 701 S Ridge Avenue, Troy, OH 45374 Item # Quantity WITH BLOWER DRYER FLIGHT-TYPE DISHER C.S.I. Section 11400 STANDARD FEATURES Pumped rinse system (pressure gauge not required) Water usage 58 gph Digital

More information

MECHANICAL EXHAUST VENTILATION SYSTEMS OPERATIONAL GUIDELINES-REVISED 2003

MECHANICAL EXHAUST VENTILATION SYSTEMS OPERATIONAL GUIDELINES-REVISED 2003 MECHANICAL EXHAUST VENTILATION SYSTEMS OPERATIONAL GUIDELINES-REVISED 2003 California Conference of Directors of Environmental Health I. Background Proper venting and capture of the gases, heat, grease,

More information

APPENDIX 3J FOOD SERVICES SPECIFICATIONS

APPENDIX 3J FOOD SERVICES SPECIFICATIONS APPENDIX 3J FOOD SERVICES SPECIFICATIONS 1. FOOD SERVICES 1.1 Design Consultant Project Co will retain as part of its professional design team a qualified food service consultant that is a professional

More information

Perm 20 Perm 17. Perm 21. Perm 15. Perm 23. Office Warehouse. Money Room. Perm 7. Perm 8. Perm 1 Perm 2. Outdoor Storage. Perm 3.

Perm 20 Perm 17. Perm 21. Perm 15. Perm 23. Office Warehouse. Money Room. Perm 7. Perm 8. Perm 1 Perm 2. Outdoor Storage. Perm 3. Perm 20 Perm 17 Perm 21 Perm 15 Perm 23 Office Warehouse Money Room Perm 1 Perm 2 Perm 3 Perm 7 Perm 6 Perm 8 Outdoor Storage QTY Perm 1 (A) 1 Beer dispensing system, Polar, built in 1 Fire suppression

More information

Tips & Tricks to Keep Your Equipment Season Ready!

Tips & Tricks to Keep Your Equipment Season Ready! Tips & Tricks to Keep Your Equipment Season Ready! 2015 Learning Objective Familiarity with different types of maintenance activities Benefits of Preventive Maintenance (PM) Awareness & Challenges of PM

More information

HVAC Equipment Access Equipment Location

HVAC Equipment Access Equipment Location City of Lancaster- Building Department 121 East Chestnut Street, Suite 102, Lancaster, Ohio 43130-3825 (740) 687-6649, Fax (740) 681-5030 Web site: www.ci.lancaster.oh.us/dept/building HVAC Heating, Ventilating,

More information

Institutions NUMBER: Food Service Safety And Sanitation

Institutions NUMBER: Food Service Safety And Sanitation Page 2 of 6 PROCEDURES: I. Safety: General safety guidelines for FSMs include: A. Handling of Supplies: When handling or storing supplies, food service staff and prisoners must: 1. Use proper lifting techniques.

More information

Commercial Kitchen Exhaust Requirements Kitchen Exhaust for Food Service Operations

Commercial Kitchen Exhaust Requirements Kitchen Exhaust for Food Service Operations Commercial Kitchen Exhaust Requirements Kitchen Exhaust for Food Service Operations District of Lake Country 10150 Bottom Wood Lake Road Lake Country, BC V4V 2M1 t: 250-766-6675 f: 250-766-0200 Inspection

More information

FT1000 FLIGHT-TYPE DISHWASHER

FT1000 FLIGHT-TYPE DISHWASHER Item # Quantity C.S.I. Section 11400 FLIGHT-TYPE DISHER STANDARD FEATURES Pumped rinse system (pressure gauge not required) Water usage 58 gph Digital controls with machine diagnostics Low temperature

More information

Bevier Sustanability Bevier Hall 905 S Goodwin Urbana, IL 61801

Bevier Sustanability Bevier Hall 905 S Goodwin Urbana, IL 61801 Proposal 1/26/2018 To: Project: From: Philips Carter 905 S Goodwin Urbana, IL 61801 Bevier Hall 905 S Goodwin Urbana, IL 61801 KEC Design LLC Steve Smith 301 Mercury Drive #2 Champaign, IL 61822 217.356.1640

More information

Number of sides for work space where food preparation occurs. Minimum width between food equipment and walls in work space.

Number of sides for work space where food preparation occurs. Minimum width between food equipment and walls in work space. This guide will assist you with providing information required by the Anne Arundel County Department of Health to determine compliance with COMAR 10.15.03 Food Service Facilities. The applicant or owner

More information

REQUIREMENTS FOR HOOD PLANS

REQUIREMENTS FOR HOOD PLANS DEPARTMENT OF PUBLIC HEALTH Division of Environmental Health REQUIREMENTS FOR HOOD PLANS Submit one (1) set of plans drawn to scale of at least ¼-inch per foot. Plans shall conform to applicable California

More information

E Q U I P M E N T S C H E D U L E

E Q U I P M E N T S C H E D U L E 28 28 24 37 2x48 2x48 2x48 28 28 27 38 32 36 57 43 43 43 58 3 49 48 4 25 38 33 35 40 39 56 59 30 5 9 7 8 9 0 2 3 3 5 25 4 6 38 46 40 46. 34 29 39 34 54 53 40 42 8 9 20 2 42 7 2 26 26 26 26 23 5 5 50 60

More information

Mobile Vendors Bulletin

Mobile Vendors Bulletin Mobile Vendors Bulletin NUMBER: 13-01 Amended Jan 18, 2016 PURPOSE City of Penticton Regulations for Mobile Vendors This guideline is intended to provide an overview of the City of Penticton requirements

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-11 44 00 (August 2017) ---------------------------- Preparing Activity: USACE Superseding UFGS-11 44 00 (January 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

MSYS 4490 AC Systems

MSYS 4490 AC Systems MSYS 4490 AC Systems Winter 2015 KITCHEN VENTILATION SYSTEMS By Satwinder Singh 12/02/2015 1 12/02/2015 2 By Satwinder Singh 1 12/02/2015 3 12/02/2015 4 By Satwinder Singh 2 Type I: Types of Hoods used

More information

18 gallons total capacity. Counter mounted separate toggle switch for independent bowl operation.

18 gallons total capacity. Counter mounted separate toggle switch for independent bowl operation. Item Qty Description Class Funding Spec Remarks Utilities Dispenser Regular, service C OMRNG 8 silverware holders, for dispensing None 1 2 tray, silverware trays 2 2 Dispensers, tableware C OMRNG self-leveling,

More information

FOOD SERVICE May 6, 2016

FOOD SERVICE May 6, 2016 FOOD SERVICE May 6, 2016 I. PROGRAM REQUIREMENTS Refer to the project-specific Schedule of Spaces for student stations, square footage, and any requirements that may differ from the prototype requirements

More information

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. U.S.A. WARNING FOR YOUR

More information

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

B.C.S. Shop Heaters 26, 30 & 36 (36 shown) BIOMASS COMBUSTION SYSTEMS, INC. 67 MILLBROOK ST., SUITE 502 WORCESTER, MA 01606 508-798-5970 - FAX 508-798-5971 B.C.S. Shop Heaters 26, 30 & 36 (36 shown) INSTALLATION MANUAL HAND FIRED SYSTEMS 8-09 Biomass

More information

DIVISION 11 EQUIPMENT. Special equipment shall be designed with the following considerations:

DIVISION 11 EQUIPMENT. Special equipment shall be designed with the following considerations: GENERAL DIVISION 11 EQUIPMENT Special equipment shall be designed with the following considerations: Integration with existing systems, equipment or programs Service and maintenance access Maintenance

More information

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST Item # Quantity C.S.I. Section 11400 DISHWASHER STANDARD FEATURES 244 racks per hour Opti-RinSe system Ball detent clutch conveyor drive mechanism Top mounted controls Stainless steel anti-clogging wash

More information

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives Design Considerations for Commercial Kitchen Ventilation By John A. Clark, P.E., Member ASHRAE Commercial kitchen ventilation (CKV) design must consider everything needed to be coordinated to form a system

More information

LOT# QTY. DESCRIPTION 1 1 ROBOT COUPE R3 2 1 EASY WEIGH PX60 DIGITAL SCALE 3 3 SAUCE PANS 4 42 SHEET PANS 5 39 STAINLESS STEEL PANS 6 10 FRY PANS 7 6

LOT# QTY. DESCRIPTION 1 1 ROBOT COUPE R3 2 1 EASY WEIGH PX60 DIGITAL SCALE 3 3 SAUCE PANS 4 42 SHEET PANS 5 39 STAINLESS STEEL PANS 6 10 FRY PANS 7 6 LOT# QTY. DESCRIPTION 1 1 ROBOT COUPE R3 2 1 EASY WEIGH PX60 DIGITAL SCALE 3 3 SAUCE PANS 4 42 SHEET PANS 5 39 STAINLESS STEEL PANS 6 10 FRY PANS 7 6 STAINLESS STEEL BOWLS 8 1 COLENDER 9 2 POTS 10 1 STOCK

More information

Raul Aragon. manufacture warranty

Raul Aragon. manufacture warranty SOCORRO INDEPENDENT SCHOOL DISTRICT Summary Sheet Contracted Services for Food Service Equipment, Repair Parts and Materials CSP No. 199-0829-E1305 Awarded: October 16, 2012 Expires: October 16, 2013 Extended:

More information

APPUZO RANGE HOOD INSTALLATION

APPUZO RANGE HOOD INSTALLATION IMPORTANT SAFETY INFORMATION TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY, PLEASE READ THE FOLLOWING: Use the range hood only in the manner intended by the manufacturer. If you have questions,

More information

PLAN REVIEW GUIDELINES AND SPECIFICATIONS FOR FOOD SERVICE ESTABLISHMENTS

PLAN REVIEW GUIDELINES AND SPECIFICATIONS FOR FOOD SERVICE ESTABLISHMENTS PLAN REVIEW GUIDELINES AND SPECIFICATIONS FOR FOOD SERVICE ESTABLISHMENTS COURTESY OF WHITMAN COUNTY DEPARTMENT OF PUBLIC HEALTH ENVIRONMENTAL HEALTH SECTION 310 NORTH MAIN STREET COLFAX, WA 99111 (509)

More information

Hinesville First United Methodist Church SECTION RESIDENTIAL APPLIANCES

Hinesville First United Methodist Church SECTION RESIDENTIAL APPLIANCES SECTION 11 3100 RESIDENTIAL APPLIANCES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

2012 INTERNATIONAL FUEL GAS CODE VENTS

2012 INTERNATIONAL FUEL GAS CODE VENTS 2012 INTERNATIONAL FUEL GAS CODE SECTION 502 (IFGC) VENTS 502.1 General. All vents, except as provided in Section 503.7, shall be listed and labeled. Type B and BW vents shall be tested in accordance with

More information

Metos Marine Core Items 2018

Metos Marine Core Items 2018 Metos Marine Core Items 2018 All Equipment for Marine Galley, Scullery and Laundry www.metos.com Sales and Marketing Metos Oy Ab / Metos Marine Ahjonkaarre FI-04220 Kerava, FINLAND Tel. int. +358 204 39

More information

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER Item # Quantity C.S.I. Section 11400 FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER STANDARD FEATURES Opti-RinSe system with dual rinse Water usage 72 gph @ 20 psi Microprocessor controls Low temperature

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-11 31 13 (August 2008) --------------------------- Preparing Activity: NAVFAC Superseding UFGS-11 31 13 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

MANDATORY CHECKLIST FOR NEW CONSTRUCTION OR REMODEL OF FOOD ESTABLISHMENT REMODEL NEW SQUARE FEET OF FACILITY DATE

MANDATORY CHECKLIST FOR NEW CONSTRUCTION OR REMODEL OF FOOD ESTABLISHMENT REMODEL NEW SQUARE FEET OF FACILITY DATE County of Santa Cruz ENVIRONMENTAL HEALTH HEALTH SERVICES AGENCY 701 OCEAN STREET, ROOM 312, SANTA CRUZ, CA 95060-4073 (831) 454-2022 FAX: (831) 454-3128 TDD: 711 www.scceh.com MANDATORY CHECKLIST FOR

More information

CADDY CORPORATION. Utility Distribution Systems

CADDY CORPORATION. Utility Distribution Systems Food Service Equipment Air Systems Utility Distribution Systems page 1 of 2 Equipment Specifications General Specifications Caddy Corporation of America Energy Distribution and Management System, which

More information

TARRANT COUNTY PUBLIC HEALTH DEPARTMENT fax FOOD ESTABLISHMENT REVIEW APPLICATION

TARRANT COUNTY PUBLIC HEALTH DEPARTMENT fax FOOD ESTABLISHMENT REVIEW APPLICATION TARRANT COUNTY PUBLIC HEALTH DEPARTMENT 817-321-4960 fax 817-321-4961 FOOD ESTABLISHMENT REVIEW APPLICATION Date: NEW REMODEL Name of Establishment: Category: Restaurant Institution Daycare Retail Market

More information

Line #: 1a, 1b, 1c (CCSD # 2) PASS-THRU HEATED CABINET (NARROW): VICTORY HS-1D-1-PT, ONLY

Line #: 1a, 1b, 1c (CCSD # 2) PASS-THRU HEATED CABINET (NARROW): VICTORY HS-1D-1-PT, ONLY Line #: 1a, 1b, 1c (CCSD # 2) PASS-THRU HEATED CABINET (NARROW): VICTORY HS-1D-1-PT, ONLY A. Provide one-section pass-thru heated cabinet. Net storage capacity to be minimum 23.7 cubic feet. Provide with

More information

SOKOL & ASSOCIATES SOKOL & ASSOCIATES. Proven Success and Experience in Selling Business Proven Success and Experience in Selling Business

SOKOL & ASSOCIATES SOKOL & ASSOCIATES. Proven Success and Experience in Selling Business Proven Success and Experience in Selling Business 3 SHEETS 560 S HIGH ST Columbus Oh Business for Sale: $99,000 64-204-4904 This Restaurant space was gutted and remodeled completely in 20. They updated all plumbing, electric, hvac, water tanks, wood floors,

More information

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection: FIRE DEPARTMENT Kitchen Range Hood Fire Suppression System Acceptance Test Project Name: Project Address: Installer Name: Installer Address: Date of Inspection: DOCUMENTATION NO Plans have been reviewed

More information

FOOD SERVICE May 6, 2016

FOOD SERVICE May 6, 2016 FOOD SERVICE May 6, 2016 I. PROGRAM REQUIREMENTS Refer to the project-specific Schedule of Spaces for student stations, square footage, and for any requirements that may differ from the prototype requirements

More information

FT900BD FLIGHT-TYPE DISHWASHER

FT900BD FLIGHT-TYPE DISHWASHER Item # Quantity C.S.I. Section 11400 FT900BD FLIGHT-TYPE DISHWASHER STANDARD FEATURES Opti-RinSe system Water usage 120 gph @ 20 psi Microprocessor controls Low temperature alert Blower dryer with 2 H.P.

More information

083a. 81a. 26a 26b b 074a B B B02 B19 B18 B17 B08. B24a B24 B09 B15 B14 9' - 0" a 009b 002 4' - 1"

083a. 81a. 26a 26b b 074a B B B02 B19 B18 B17 B08. B24a B24 B09 B15 B14 9' - 0 a 009b 002 4' - 1 085 116 089 087 088 089 083a GENERAL NOTES KAMRAN AND COMPANY, INC. (KAMRAN) MAKES NO WARRANTIES, REPRESENTATIONS OR GUARANTEES OF ANY KIND OR NATURE, EXPRESS OR IMPLIED, WITH RESPECT TO THE ACCURACY,

More information

CULINARY OPERATIONS September 30, 2010

CULINARY OPERATIONS September 30, 2010 CULINARY OPERATIONS September 30, 2010 I. PROGRAM REQUIREMENTS Refer to the project-specific Schedule of Spaces for student stations, square footage, and for any requirements that may differ from the prototype

More information

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001 EFFECTIVE: SEPTEMBER 1, 2001 ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 211-0044L-R / 212-0044R-L ADC-44 Conveyor Dishwasher 2

More information

SECTION PLUMBING

SECTION PLUMBING SECTION 22 10 00 PLUMBING PART 1 GENERAL 1.1 WORK INCLUDED A. Furnish all labor, material and equipment necessary for the complete installation of the sanitary sewer system (including soil and vent piping),

More information

K DINING AND FOOD SERVICE

K DINING AND FOOD SERVICE K DINING AND FOOD SERVICE INTRODUCTION The food services for the facility will serve a projected population of approximately 584 residents and 70-00 staff members. AFRH Gulfport is a 24-hour, 365-days-a-year

More information

B E ROUTE DUCT BEHIND BOOKSHELF. GRILLE MOUNTED ON TOP OF BENCH. BOOK CASE WALL 12x8 8x5 I 8"Ø 7"Ø 125 CFM I D M FLOOR SIDE WALL VENT 6x5 160 CFM 6"Ø 6"Ø 8x10 J C G 1 Section M-1 NOT TO SCALE Project No

More information

CONSTRUCTION REQUIREMENTS FOR MOBILE FOOD FACILITIES

CONSTRUCTION REQUIREMENTS FOR MOBILE FOOD FACILITIES City and County of San Francisco DEPARTMENT OF PUBLIC HEALTH ENVIRONMENTAL HEALTH BRANCH Consumer Protection Edwin M. Lee, Mayor Barbara A. Garcia, MPA, Director of Health Stephanie K.J. Cushing, MSPH,

More information

CARL S JR REPLACEMENT PARTS FOR STORE LEVEL REFRIGERATION EQUIPMENT --PREPARATION EQUIPMENT COOKING EQUIPMENT SERVING EQUIPMENT MISCELLANEOUS

CARL S JR REPLACEMENT PARTS FOR STORE LEVEL REFRIGERATION EQUIPMENT --PREPARATION EQUIPMENT COOKING EQUIPMENT SERVING EQUIPMENT MISCELLANEOUS PH 800.458.5593 FX 800.800.4981 www.hfse.com CARL S JR REPLACEMENT PARTS FOR STORE LEVEL TABLE OF CONTENTS TABLE OF CONTENTS --PREPARATION EQUIPMENT BERKEL - SHARPENER - 909 & 919...2 NEMCO - EASY VEGETABLE

More information

A. Standards: Except where modified or exceeded by the requirements of this Specification, conform to the following standards:

A. Standards: Except where modified or exceeded by the requirements of this Specification, conform to the following standards: SECTION 11 53 53 BIOLOGICAL SAFETY CABINETS PART 1 - GENERAL 1.1 QUALITY ASSURANCE A. Standards: Except where modified or exceeded by the requirements of this Specification, conform to the following standards:

More information

GRILLE, REGISTER AND DIFFUSER SCHEDULE

GRILLE, REGISTER AND DIFFUSER SCHEDULE ROOFTOP UNIT SCHEDULE (NATURAL GAS HEAT) MARK MANUFACTURER MODEL SUPPLY FAN COOLING COIL HEAT EXCHANGER MIN. MIN. MCA MOCP V/PH WEIGHT NOTES FAN CFM MIN ESP REFR. TH SH EAT LAT MIN. OUTPUT MIN. EFF. NOM.

More information

A. INSTALL as used in this section means to set in place, complete, secure, anchor and connect and in fully operational condition.

A. INSTALL as used in this section means to set in place, complete, secure, anchor and connect and in fully operational condition. Section 11 40 00 Foodservice Equipment PART I GENERAL 1.1 SCOPE OF WORK A. Furnish labor, materials and service necessary for the installation/assembly of foodservice equipment provided by Direct Supply

More information

Installation Instructions

Installation Instructions Installation Instructions 30" ELECTRIC Downdraft Cooktop Modules selected at time of purchase IMPORTANT: Read and save these instructions. Part No. 208040 A 438589 Quick Reference Table of Contents: Pages

More information

JFT Flight Machine. JFT Flight Machine. Models. Options. Standard Features. JFT Flight Machine

JFT Flight Machine. JFT Flight Machine. Models. Options. Standard Features.   JFT Flight Machine JFT Flight Machine Models JFT Flight Machine Options Project Item Quantity CSI Section 00 Approval Date Blower dryer Additional wash section Additional load module Additional unload module (8m) wash down

More information

ADAMS COUNTY HEALTH DEPARTMENT PLAN REVIEW APPLICATION FOR FOOD ESTABLISHMENTS This is not a Food Establishment application. Fees are non refundable

ADAMS COUNTY HEALTH DEPARTMENT PLAN REVIEW APPLICATION FOR FOOD ESTABLISHMENTS This is not a Food Establishment application. Fees are non refundable A7 ADAMS COUNTY HEALTH DEPARTMENT 108 W. MAIN, RITZVILLE, WASHINGTON 99169 - TELEPHONE (509) 659-3315 425 E. MAIN, STE. 700, OTHELLO, WASHINGTON 99344 - TELEPHONE (509) 488-2031 ADAMS COUNTY HEALTH DEPARTMENT

More information

ll. Consistency Questions

ll. Consistency Questions Our Goal is FOR ALL STAKEHOLDERS TO HAVE A SUCCESSFUL PROJECT with us and that together we keep people and structures safe and buildings economically viable to serve the needs of our community. We strive

More information

FOOD ESTABLISHMENT PLAN REVIEW APPLICATION TO BE COMPLETED AND SUBMITTED TO:

FOOD ESTABLISHMENT PLAN REVIEW APPLICATION TO BE COMPLETED AND SUBMITTED TO: SF-35 Rev. 11-08 FOOD ESTABLISHMENT PLAN REVIEW APPLICATION TO BE COMPLETED AND SUBMITTED TO: Kanawha-Charleston Health Department 108 Lee Street, East PO Box 927 Charleston, West Virginia 25323 Phone:

More information

Layout & Design. The layout of this kitchen reflects a design appropriate to a fast food facility that would

Layout & Design. The layout of this kitchen reflects a design appropriate to a fast food facility that would Layout & Design The layout of this kitchen reflects a design appropriate to a fast food facility that would be located in the food court at San Francisco State University. Those food service facilities

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-11 31 13 (August 2017) --------------------------- Preparing Activity: NAVFAC Superseding UFGS-11 31 13 (August 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

KITCHEN EQUIPMENT'S LEGEND (THE DECK-IHC)- ANNEX -IV

KITCHEN EQUIPMENT'S LEGEND (THE DECK-IHC)- ANNEX -IV KITCHEN EQUIPMENT'S LEGEND (THE DECK-IHC)- ANNEX -IV DIMENSIONS IN INCHES ELECTRICAL LOAD WATER SUPPLY DRAIN LPG/COAL Btu's/hr at 4.5 S.NO. DESCRIPTION QTY. psig input pressure per Rate L W H B/SPL KW/UNIT

More information

Installation Instructions Wall Ovens

Installation Instructions Wall Ovens Installation Instructions Wall Ovens TESTED IN ACCORDANCE WITH THE LATEST EDITION OF UL858 STANDARD FOR HOUSEHOLD ELECTRIC COOKING APPLIANCES. IMPORTANT 1. Before beginning installation, please thoroughly

More information

Models. Options. Standard Features. LoH 2 O

Models. Options. Standard Features.   LoH 2 O LoH O Models LoH O Standard Features Uses 8 gallons (9. liters) of water per hour with sanitizing hot water rinse All tanks and hoods constructed from durable stainless steel with a No. finish and heliarced

More information

Mariposa County Health Department

Mariposa County Health Department Mariposa County Health Department Eric Sergienko, MD, MPH, Director Public Health Section 5085 Bullion Street Post Office Box 5 Mariposa, California 95338 (209) 966-3689 FAX (209) 966-4929 Environmental

More information

CL44eN-BAS DISHWASHER

CL44eN-BAS DISHWASHER Item # Quantity C.S.I. Section 11400 CL44eN-BAS DISHWASHER STANDARD FEATURES 202 racks per hour Opti-RinSe system Rapid return conveyor drive mechanism Insulated hinged double doors with door interlock

More information

CL64eN-BAS DISHWASHER

CL64eN-BAS DISHWASHER Item # Quantity C.S.I. Section 110 DISHWASHER STANDARD FEATURES 342 racks per hour Opti-RinSe system Rapid return conveyor drive mechanism Insulated hinged double doors with door interlock switches 19.5

More information

breeze easytm model # F100-1W

breeze easytm model # F100-1W DewStop breeze easytm model # F100-1W Installation Guide Read and Save These Instructions LISTED Questions, Problems, Missing Parts? Please Call 1-360-876-2974 or E-Mail info@dewstop.com please retain

More information

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS INSTALLATION and OPERATION INSTRUCTIONS Utility Coolers MODEL NOS. US4KP US10KP IMPORTANT INFORMATION This manual has been prepared to assist you in the installation of your Utility Cooler and to acquaint

More information

FOOD ESTABLISHMENT PLAN REVIEW APPLICATION Branch-Hillsdale-St. Joseph Community Health Agency

FOOD ESTABLISHMENT PLAN REVIEW APPLICATION Branch-Hillsdale-St. Joseph Community Health Agency Date received: C receipt#:_ FOOD ESTABLISHMENT PLAN REVIEW APPLICATION Branch-Hillsdale-St. Joseph Community Health Agency Branch County Office: Hillsdale County Office: St. Joseph County Office: 570 N.

More information

INVENTORY LIST FOR ROK-N-ROBIN Z DINER KITCHEN AREA

INVENTORY LIST FOR ROK-N-ROBIN Z DINER KITCHEN AREA INVENTORY LIST FOR ROK-N-ROBIN Z DINER KITCHEN AREA Walk in Cooler 12X8 with Metro Green Epoxy Shelving Walk in Freezer 12X12 True single Solid Door Freezer Up Right Stainless inside out True stainless

More information

CASH CREDIT CHECK # INVOICE# FOOD SERVICE ESTABLISHMENT PLAN REVIEW APPLICATION

CASH CREDIT CHECK # INVOICE# FOOD SERVICE ESTABLISHMENT PLAN REVIEW APPLICATION KENDALL COUNTY HEALTH DEPARTMENT ENVIRONMENTAL HEALTH UNIT 811 W. JOHN STREET YORKVILLE, IL 60560 (630) 553-9100, Ext. 8026 FAX (630) 553-9603 www.kendallhealth.org FOR OFFICE USE ONLY PLANS REC D: / /

More information

SECTION DUCTWORK

SECTION DUCTWORK PART 1 GENERAL 1.1 REFERENCES SECTION 23 31 00 DUCTWORK A. ASHRAE - Handbook, Duct Design B. ASHRAE - Handbook, Duct Construction C. ASTM A90/A90M - Standard Test Method for Weight (Mass) of Coating on

More information

C44A/C44AW DISHWASHER

C44A/C44AW DISHWASHER Item # Quantity C.S.I. Section 11400 C44A/C44AW DISHWASHER STANDARD FEATURES 202 racks per hour C44A 126 racks per hour C44AW Opti-RinSe system Ball detent clutch conveyor drive mechanism Top mounted controls

More information

Specifications 2/11/2014

Specifications 2/11/2014 2//204 Item K0A - Project CPC NY Project 54 Old Westbury Road Old Westbury NY 568 RANGE, 36", 6 OPEN BURNERS ( REQ'D) From Supreme Restaurant Equipment Matt Hancock cell 423-763-8386 797 Old Lee Highway

More information

KITCHEN A104 CAFETERIA A103 RECEIVING WALK-IN FREEZER WALK-IN COOLER ENTRY EXIT EXIT COOKING PREP ENTRY WAREWASHING DRY STORAGE TRAY RETURN

KITCHEN A104 CAFETERIA A103 RECEIVING WALK-IN FREEZER WALK-IN COOLER ENTRY EXIT EXIT COOKING PREP ENTRY WAREWASHING DRY STORAGE TRAY RETURN 4/19/2014 6:48:50 PM FROM FILE: S:\2013\-4j_Howard_Elementary_School\Drawings\Revit\_HES_ARH_Bldg_14.rvt REEIVING DRY STORAGE WALK-IN OOLER PREP WALK-IN FREEZER KITHEN A104 OOKING WAREWAING AFETERIA A103

More information