ADAPT Parasol EX a. Installation - Commissioning - Maintenance ADAPT Parasol EX a - m A1, B1

Size: px
Start display at page:

Download "ADAPT Parasol EX a. Installation - Commissioning - Maintenance ADAPT Parasol EX a - m A1, B1"

Transcription

1 ADAPT Parasol EX a Installation - Commissioning - Maintenance A1, B1 ADAPT Parasol EX a - m A2 B2 1

2 ADAPT Parasol EX a - m A3 B3 M6 B4 A4 A5 A6, B5 2

3 ADAPT Parasol EX a - m A7, B6 male thread DN (1/2 ) Note that clamp ring couplings require support sleeves inside the pipes. A8, B7 d/2 3

4 ADAPT Parasol EX a - m A9, B8 B A9, B8 C F G H B I C F G H I or SH or SH A10, B9 A B C D E F G H I or SH black white Sensor blue Condens red yellow 0-10V DC red black white 24V 24V G0 G0 24V 24V brown (US=white) blue (US=black) 0-10V DC G0 G0 G G Wiring when not using VOC sensor 2. Wiring when using VOC sensor 4 Sensor Condens Swegon reserves the right to alter specifications. brown (US=white) brown blue grey green blue (US=black) black black white brown white CO2 brown VOC SHoR

5 ADAPT Parasol EX a - m A11, B10 A12, B11 TORX T-25 / 1 x 8 A13, B12 A14, B13 Click! ON 1 2 ON 1 2 5

6 ADAPT Parasol EX a - m A15, B14 A16 B15 A17, B16 6

7 ADAPT Parasol EX a - m A18, B17 A19, B18 7

8 ADAPT Parasol EX a - m Super WISE Next Zone CONTROL Zone MB MB1 RS -485 type Belden 9842 MB id 1 G 24 A B G 24 A B ADAPTER RJ12/WIRE Master/Master with SuperWISE system Modular 6/6 RJ12 Modular 6/6 RJ12 Modular 6/6 RJ MB id 4 Master MB id 8 Master MB id 12 Master Master/Slave with SuperWISE system Modular 6/6 RJ12 Modular 6/6 RJ MB id 4 Master MB id 1 Slave id 1 MB id 2 Slave id 2 BMS RS 485 Master/Slave with BMS sytem Modular 6/6 RJ12 Modular 6/6 RJ MB id 1 Master MB id 2 Slave id 1 MB id 3 Slave id 2 8

9 ADAPT Parasol EX a Installation -Commissioning - Maintenance K factor, sides = k2 = max. flow ADAPT Parasol EX 2 3 k-factor per side Size Nozzle setting per side Side * ** 690 L 1& L 2& M 1& K factor, sides = k1 = min. flow M 2& H 1& H 2& L 1&3 0,253 0, L 2&4 0 0, M 1&3 0,44 0, M 2&4 0 1, H 1&3 0,693 0,693 ADAPT Parasol EX a - m 1290 H 2&4 0 1,825 * ) = k-factor for adjusting the min. flow. ** ) = k-factor for adjusting the max. flow. q i ( ) 2 1 p = [Pa] k q = k p i [l/s] [pi Pa] q [l/s] k = k-factor ADAPT Parasol EX Size Example nozzle setting k pl *** ) k1 k2 690 LLLL LHLH MMMM HHHH LLLL , LHLH , MMMM , HHHH ,04 *** ) All four sides on the unit can be set individually. The designation of the nozzle setting follows the order of figure to the left. k1 = No occupancy flow k2 = Max. occupancy flow k1 / k2 K p = 0.50 / 3.66 OBS! Any change between max. and min. flow will slightly change the nozzle pressure. 9

10 ADAPT Parasol EX Commissioning/checking the airflows Constant pressure in zone with CONTROL Zone or similar zone damper. 1. Check that all the WISE products are energised. T x 8 Nozzle configuration H M L H = M= L= 2. Ensure that all the ADAPT Parasol EX modules have their correct C-factors and minimum and maximum flows preset. Ensure that all are set to the maximum flow commissioning position, (3 blue + 3 red LEDs are lit). 3. Check the flow, compare the maximum flow in the zone, adjust the pressure setpoint until the correct flow is obtained with TUNE Control. If Max. flow is not attained, another zone damper / other zone dampers should be temporarily closed. 4. Measure and record the airflow in the max. position on one ADAPT Parasol EX in the zone. 5. Reset to the min. flow, measure and record the airflow. 6. Set back to maximum flow. 7. Perform the same procedure for all the ADAPT Parasol EX modules in the zone. 8. Reduce the pressure setpoint setting on the zone damper if pressure is required for other zones, e.g. 5 Pa. 9. Commission the remaining zones, following the same procedure. X-shape 10. Check/commission the previous shut-off zones in the same way. 11. Restore the pressure setpoints on all the zone dampers. 12. Identify the reference zone, i.e. the zone with the lowest flow compared with the design maximum flow (e.g. by checking present airflow across each zone damper; using the TUNE Control hand unit). 13. Set the minimum flow on a number of ADAPT Parasol EX modules or use the zone damper for setting the minimum flow so that the ventilation system responds to the simultaneous load. Fan-shape 14. Now adjust the air handling unit s pressure setpoint until the zone damper of the reference zone is 85-90% open, (done by the SuperWISE, if it is used). 15. Restore all the settings and set all the ADAPT Parasol EX modules to normal position. 10

11 ADAPT Parasol EX Sensor module menu: To reach the menu, hold the left-hand and right-hand buttons down for five seconds. With the left-hand button ( ) you advance through the menus. With the right-hand button ( ) you confirm your selection and return to the menu. Press the left-hand button and select: 1. Alarm list 2. Commissioning 6. Return to menu Press the righthand button to confirm your selection 1. Alarm list: See the complete alarm list to the right. 2. Commissioning: There are then six selections in the commissioning menu, (press the left-hand button to advance in the menu). When you have marked a selection, the controller goes directly to that operating mode. 2.1 Min. airflow, holiday/ no occupancy for longer period 2.2 Min. airflow, no occupancy 2.3 Min. airflow, occupancy 2.4 Max. airflow, occupancy 2.5 Open cooling valve 2.6 Open heating valve Press the right-hand button to return to the menu. 1 and 3 are not used if ECOPulse and 2Step are in use 3, 4, 5. Not used. 6. Return to menu Function button Temperature sensor Presence detector Diodes for temperature, commissioning or alarm indication Function button Alarm list for the sensor module Alarm no. Type of alarm Alarm 1 Supply voltage low Alarm 2 Supply voltage critically low Alarm 3 Ext temp missing Alarm 4 Ext temp error Alarm 5 Condensation sensor error Alarm 6 SM temp sensor error Alarm 7 SM button error Alarm 8 CO 2 sensor missing Alarm 9 VOC Error Alarm 10 Low pressure Alarm 17 SM comm error Alarm 18 Slave comm error Alarm 19 Pressure sensor comm error Alarm 20 VOC sensor comm error Alarm 21 No master request (slave) Alarm 22 Slave incompatible version Alarm 25 Heating comfort alarm Alarm 26 Cooling comfort alarm Alarm 27 Temp. Set point overlap alarm Alarm 28 Air quality comfort alarm Alarm 29 Condensation Alarm V Out 1 overload error Alarm V Out 2 overload error Alarm V Out 3 overload error Alarm 41 Slave input common alarm Alarm 42 Slave output common alarm The alarm is displayed by a number of diodes when you have selected Alarm list (1) in the menu. Each diode represents a number as shown in the table above and the numbers should be added up to form an alarm number. Ex. The centremost blue and the two last red diodes are lit (xoxxoo) Diode-indicating function The centremost blue one corresponds to 16, the penultimate red one to 2 and the last red one to 1. The sum of - Green = Ok - Flashing Green = Condensation alarm these is 19, which is the alarm number. - Yellow = Alarm - Green/Yellow = Comfort alarm (not acute) ADAPT Parasol EX - m 3 parallel RJ12 ports (Modbus) for connecting a controller for instance, another sensor module or computer by means of Cable converter USB-RJ12 ON 1 2 Addressing the sensor module. 10 sensor modules can be connected to each master unit. Each one must have its own unique address in order to work. Switch for termination resistance. Set Switch 1 to the ON position for the last sensor module in the loop. 11

12 ADAPT Parasol EX a Installation - Commissioning - Maintenance ADAPT Parasol EX a - m 7 3 ON 1 2 ON Art.no

ADAPT PARASOL a. Installation - Commissioning - Maintenance ADAPT Parasol - m

ADAPT PARASOL a. Installation - Commissioning - Maintenance ADAPT Parasol - m ADAPT PARASOL a Installation - Commissioning - Maintenance 2013-12-04 ADAPT Parasol 600 / 600 PF ADAPT Parasol 1200 / 1200 PF M6 1 Water Position of waterpipes ADAPT Parasol 600 / 600 PF 600 Värme retur/

More information

ADAPT Parasol EXb. Installation. Installation Commissioning Maintenance A1, B1

ADAPT Parasol EXb. Installation. Installation Commissioning Maintenance A1, B1 b Installation Commissioning Maintenance 20160503 Installation A1, B1 A2 B2 A3 B3 M8 B4 A4 A5 A6, B5 2 Swegon reserves the right to alter specifications. 20160503 Water A7, B6 utvändig DN15 (1/2 ) gänga

More information

ADAPT Parasol EX. Energy-saving, suspended comfort module QUICK FACTS

ADAPT Parasol EX. Energy-saving, suspended comfort module QUICK FACTS Energy-saving, suspended comfort module QUICK FACTS Suspended comfort modules for demand-controlled ventilation and Swegon s WISE system. Energy-efficient operation since the room is ventilated, heated

More information

PARASOL EX. Suspended comfort modules QUICK FACTS

PARASOL EX. Suspended comfort modules QUICK FACTS Suspended comfort modules QUICK FACTS 4-way air distribution, where each side has readjustable airflow rate and adjustable direction of air discharge for maximum comfort. High capacity occupies little

More information

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation Overview Demand-controlled Ventilation Leading edge products for demand-controlled ventilation Demand-controlled ventilation offers great comfort and low operating costs When the room is in use, ventilation

More information

21-light Remote Annunciator. Owner s Manual

21-light Remote Annunciator. Owner s Manual 21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With

More information

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C 1. General The hand-held micro terminal is used for setting the motor parameters of the SILVER C. 2. Installation

More information

PARAGON. Compact comfort module. Key figures

PARAGON. Compact comfort module. Key figures Compact comfort module www.eurovent-certification.com www.certiflash.com Comfort module is the name of a new family of compact comfort modules especially designed for use in hotels and hospitals. provides

More information

System technology. Demand controlled ventilation WISE.

System technology. Demand controlled ventilation WISE. System technology Demand controlled ventilation www.swegon.com Content Room products... 3 Operation... 3 Accessories... 6 Sizing, example... 7 Zone products... 9 Operation... 9 Accessories... 9 Sizing,

More information

Natural Ventilation Controller with 24vDC drive NVC-1204

Natural Ventilation Controller with 24vDC drive NVC-1204 Natural Ventilation Controller with 24vDC drive NVC-1204 BACnet Enabled C-036 08/11 FEATURES > 24V DC supply > Native BACnet communications > Master/Slave grouping (shared information) > 3 x 0-10V outputs

More information

DAP III Zone Master User s Guide

DAP III Zone Master User s Guide DAP III Zone Master User s Guide Data Aire, Inc. 230 West BlueRidge Avenue Orange, California 92865 Document Number 600-000-788 March 2010 Revision 1.0 Document # 600-000-788 1 Overview The Data Aire DAP

More information

Digital Marine Exhaust Temperature Alarm

Digital Marine Exhaust Temperature Alarm Digital Marine Exhaust Temperature Alarm Model: SM007D/S INTRODUCTION COMPONENTS Marine water cooled exhaust systems are designed to withstand temperatures of up to about 120 C. However the exhaust gases

More information

prestige Control Application Supplement - ACVMax

prestige Control Application Supplement - ACVMax 2015-10 Prestige ACVMax Control Sup 12-14-15_ACVMax_Control 12/15/15 7:36 AM Page 1 prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory

More information

P2267 NETWORK INTERFACE

P2267 NETWORK INTERFACE P2267 NETWORK INTERFACE USER MANUAL FOR OPERATING SYSTEMS: 22031-03 23636-01 October 2009 Associated Controls (Australia) Pty. Limited 2-4 Norfolk Road Greenacre, NSW, 2190. PH +61 2 9642 4922, FAX +61

More information

Installation Instructions for the TBLZ-2-66 control box. for controlling two air handling units (Twin Function) GOLD RX

Installation Instructions for the TBLZ-2-66 control box. for controlling two air handling units (Twin Function) GOLD RX Installation Instructions for the TBLZ-2-66 control box. for controlling two air handling units (Twin Function) GOLD RX 04-120 1. General The TBLZ-2-66 accessory is a control system incorporated into a

More information

Control Application. Supplement - ACVMax

Control Application. Supplement - ACVMax prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

Natural Ventilation Controller with 24vDC drive NVC-1204

Natural Ventilation Controller with 24vDC drive NVC-1204 Natural Ventilation Controller with 24vDC drive NVC-1204 BACnet Enabled C-038 08/16 FEATURES SPECIFICATION > 24V DC supply > Native BACnet communications > Master/Slave grouping (shared information) >

More information

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES Swegon PACIFIC Integrated chilled beam PACIFIC CHILLED BEAM The PACIFIC is a high performance chilled beam for installation in false ceilings. Built-in flexibility, designed to meet the needs of today

More information

FCCP 200: Fume-cupboard indicator and monitor

FCCP 200: Fume-cupboard indicator and monitor Product data sheet 3.1 43.170 FCCP 200: Fume-cupboard indicator and monitor How energy efficiency is improved Display and interface for safe, energy-efficient monitoring of fume cupboards, pressure zones

More information

OVEN INDUSTRIES, INC.

OVEN INDUSTRIES, INC. OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and

More information

OJ Waterline control system

OJ Waterline control system OJ Waterline control system THERMOSTATS FOR COMFORT HEATING AND SNOW MELTING Product presentation Mk3 It s all about Room Temperature Control! The essential main goals are: Comfort Flexibility Reliability

More information

User Guide: *IG1605EW*

User Guide: *IG1605EW* User Guide: IntelliZone2 MasterStat System Communicating with Humidity Control Thermostat USER GUIDE: INTELLIZONE2 MASTERSTAT COMMUNICATING THERMOSTAT Adjusting Temperature (Temporary Override in Programmable

More information

Security Escort Central Console Software SE2000 Series

Security Escort Central Console Software SE2000 Series Release Notes Security Escort Central Console Software SE2000 Series Table of Contents 1 Security Escort v2.18.1.0... 2 1.1 Enhancements... 2 1.2 Errors Fixed... 2 1.3 Known Limitations and Restrictions...

More information

SmartDial. Wireless. User Manual. -en_gb language A004. Document in original

SmartDial. Wireless. User Manual. -en_gb language A004. Document in original Wireless Document in original -en_gb language 2017-03-20 A004 Contents 1 Declaration of Conformity... 1 2 Product description... 3 3 Guidelines for installation... 4 4 Operation... 5 5 Interface Description...

More information

ARO Series. Description. Features. Modbus CO2 VOC. Networkable* ARO AROB24TGVH AROB24TGH. room controller. (AROB series only) or network

ARO Series. Description. Features. Modbus CO2 VOC. Networkable* ARO AROB24TGVH AROB24TGH. room controller. (AROB series only) or network ARO Series Universal Room Controller s Models ARO24T ARO24TH ARO24TGH ARO24TGVH Temp RH CO2 VOC Networkable* AROB24T AROB24TH AROB24TGH AROB24TGVH * Networkable: BACnet MS/TP or Modbus (selectable using

More information

Super WISE. System product for Swegon s system for demand-controlled ventilation

Super WISE. System product for Swegon s system for demand-controlled ventilation System product for Swegon s system for demand-controlled ventilation Quick facts Pressure optimisation of the supply air and extract air fans Addition and subtraction of flows within a zone Handles 80

More information

PARAGONTM Comfort module for hotel rooms and hospital wards

PARAGONTM Comfort module for hotel rooms and hospital wards PARAGONTM Comfort module for hotel rooms and hospital wards Now with improved cooling and heating capacity www.swegon.com PARAGON A PARAGON for each requirement Normal capacity NC, cooling heating, Thermal

More information

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

Corrigo E. Second generation which contains all applications and languages

Corrigo E. Second generation which contains all applications and languages revision 05 2009 Corrigo E Second generation which contains all applications and languages The controllers in the Corrigo E series are intended for applications within heating, boiler and ventilation control

More information

SIRe Advanced Air Curtains Water Ambient, no heat

SIRe Advanced Air Curtains Water Ambient, no heat Original instructions SIRe Advanced Air Curtains Water Ambient, no heat With quick guide SIReAA SE... 2 GB... 23 DE... 44 FR... 65 ES... 86 IT... 107 NL... 128 NO... 149 PL... 170 RU... 191 For wiring

More information

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h PRODUCT DATA COMFORT 5000 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 5300 m 3 /h COMFORT 5000 The Comfort 5000 is a ventilation unit suitable for central

More information

TECOM SYSTEMS NETWORK MASTER

TECOM SYSTEMS NETWORK MASTER TECOM SYSTEMS NETWORK MASTER The Tecom Network Master is a cost effective, Dialler Receiver and Direct Line Network Master combined in a single modular unit. HARDWARE The unit consists of a 3RU, 19 inch

More information

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

5, SE GÅNGHESTER,

5, SE GÅNGHESTER, KSUB Control and monitoring unit Valid from week of manufacture 48/2005 Description The KSUB is a control and monitoring unit designed to control various types of fire/smoke dampers and fans in a flexible

More information

SEQUENCE OF OPERATIONS

SEQUENCE OF OPERATIONS SEQUENCE OF OPERATIONS DDC CONTROLLER: Controller with integral LCD readout for changing set points and monitoring unit operation. Provided with required sensors and programming. Factory programmed, mounted,

More information

CM3500 Controller - ClimateMaster DOAS Water-Source Heat Pumps - Rev.: 7 Oct, 2008B

CM3500 Controller - ClimateMaster DOAS Water-Source Heat Pumps - Rev.: 7 Oct, 2008B 2 CM3500 Controller - ClimateMaster DOAS Water-Source Heat Pumps - Rev.: 7 Oct, 2008B CAUTION CAUTION - ONLY TRAINED, QUALIFIED PERSONNEL SHOULD INSTALL AND/OR SERVICE CLIMATEMASTER EQUIPMENT. SERIOUS

More information

Instructions for the fan motor control system, SILVER C

Instructions for the fan motor control system, SILVER C Instructions for the fan motor control system, SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units. The motor control system is

More information

Waterborne Climate Systems

Waterborne Climate Systems Overview Waterborne Climate Systems Optimal indoor climate with demand-controlled and energy efficient products Flexible, low energy-use + low maintenance with Swegon s climate systems! There are many

More information

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software INSTALLATION AND COMMISSIONING GUIDE CAN bus-based I/O module, CIO 208 8 relays Mounting Terminals and wiring Commissioning, using the utility software DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45

More information

PONY 2/4 User Guide 2017

PONY 2/4 User Guide 2017 PONY 2/4 User Guide 2017 Table of Contents Dose Selection 2 Cleaning 3 Waste Drawer 4 Programming 5 Formatting 6 Error Codes 8 software version v.2.12.01 August 2017 1 Dose Selection Standby All keys are

More information

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

EBC20. Instructions for fitting, installation and operation. Read and save these instructions! EBC20 UK Instructions for fitting, installation and operation Read and save these instructions! 2 3002878 EBC20 UK 290415 1. Product information............................................... 4 1.1 Delivery.............................................................

More information

MBS Therma-Fuser Standalone Motorized Swirl VAV Diffuser

MBS Therma-Fuser Standalone Motorized Swirl VAV Diffuser MBS Therma-Fuser Standalone Motorized Swirl VAV Diffuser Models: MBS-M MBS-S MBS-D Master with sensor and controller Slave with controller to follow master Drone with controller for 3rd party control Therma-Fuser

More information

SIRe Advanced Air Curtains Electric With quick guide. SIReAA GB DE FR For wiring diagram, please see last pages. ES

SIRe Advanced Air Curtains Electric With quick guide. SIReAA GB DE FR For wiring diagram, please see last pages. ES Original instructions SIRe Advanced Air Curtains Electric With quick guide SIReAA SE... 2 GB... 22 DE... 42 FR... 62 ES... 82 IT... 102 NL... 122 NO... 142 PL... 162 RU... 181 For wiring diagram, please

More information

RPM1600 Series Room Pressure Monitors

RPM1600 Series Room Pressure Monitors RPM1600 Series Room Pressure Monitors Technical Bulletin LB-RPM1611-0, LB--0 Code No. LIT-12012228 Issued October 2017 Refer to the QuickLIT website for the most up-to-date version of this document. How

More information

User's Guide. CTS6000 control panel

User's Guide. CTS6000 control panel User's Guide CTS6000 control panel Valid for: SW version 1,0092 Version 1.04, 2015-12-16 Contents Contents... 2 Figure... 2 Introduction... 3 Control panel menus... 4 Alarm log/event log... 4 Weekly program...

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

Swegon Home Solutions CASA. W3 Smart. Installation, commissioning and maintenance instruction. W3_f_EN-t

Swegon Home Solutions CASA. W3 Smart. Installation, commissioning and maintenance instruction. W3_f_EN-t Swegon Home Solutions CASA W3 Smart Installation, commissioning and maintenance instruction W3_f_EN-t Contents Installation, operation and maintenance instructions for design engineers, installation engineers

More information

Installation Instruction

Installation Instruction Installation Instruction CTS 600 by Nilan VPM 120 VPM 240 VPM 360 VPM 480 VPM 560 Version: 5.02, 17-10-2011 Table of contents Table of contents... 2 Figures... 2 General information before installation...

More information

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov 3005925_2018-02-05.fm EXcon zone control Control for up to 4 individual zones EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov Tel. +45 65 66 12 34 Fax +45 65 66 11 10 exhausto@exhausto.dk www.exhausto.dk OJ-Air2

More information

HVAC Controls Upgrades: Requirement Details ( )

HVAC Controls Upgrades: Requirement Details ( ) REQUIRED CONTROLS/FEATURES To qualify the upgrade must add or substantially modify 3 or more sequences/system capabilities. Also, all sequences and items listed under the required section are needed in

More information

Lennox Climatic 50 and BMS Modbus, Trend or BACnet.

Lennox Climatic 50 and BMS Modbus, Trend or BACnet. Lennox Climatic 50 and BMS Modbus, Trend or BACnet. Specification of the Bus: Type: RS485 Speed: (Adjustable on Climatic 50 via display ; Setting 3933) 1200 2400 4800 9600 19200 Parity: Fixed no parity

More information

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button USER MANUAL Type UCG/UDG 57116D 06/12 (MBC) 1.10 2012 OJ Electronics A/S...1 Français...7 Español... 14 Type UCG/UDG Contents Introduction...1 First Time Settings...1 Ground Fault Circuit Interrupter (GFCI)...1

More information

Swegon Home Solutions CASA. R2 Smart. Installation, commissioning and maintenance instruction. R2_a_EN-t

Swegon Home Solutions CASA. R2 Smart. Installation, commissioning and maintenance instruction. R2_a_EN-t Swegon Home Solutions CASA R2 Smart Installation, commissioning and maintenance instruction R2_a_EN-t Contents Technical Guide for design engineers, installation engineers and service personnel The section

More information

WLM2 WLTA WLTD WLTP WLCT2

WLM2 WLTA WLTD WLTP WLCT2 57640C 12/12 (MBC) User Manual WLM2 WLTA WLTD WLTP WLCT2 www.ojelectronics.com Congratulations Congratulations with you new control system for underfloor heating and cooling. The control system has been

More information

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power T M User Manual MarinaGuard Ground Fault Monitoring Panel For Marina Shore Power NAE1095810 / 03.2013 T M Bender Inc. USA: 700 Fox Chase Coatesville, PA 19320 Toll-Free: 800-356-4266 Phone: 610-383-9200

More information

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670 Bulletin AV-670 Series 670 Hood Monitor Specifications - Installation and Operating Instructions DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Phone: 219/879-8000 Fax: 219/872-9057

More information

2017 products.koer.com Page 1 of 14

2017 products.koer.com Page 1 of 14 VAV Parameters 2017 products.koer.com Page 1 of 14 INTRODUCTION Learn how to setup various VAV parameters and configurations, PID calculation elements, EC motor voltages, wall type etc. 2017 products.koer.com

More information

Manual for the integration in BMS/GTC

Manual for the integration in BMS/GTC Manual for the integration in BMS/GTC Communication parameters MODBUS RTU and BACNET COMMUNICATION UTBS PRO-REG Software Version 3.6 EN ÍNDEX 1. GENERALITIES...2 1.1. Introduction...2 1.2. signals types...2

More information

AFA 500 FUME HOOD ALARMS

AFA 500 FUME HOOD ALARMS AFA 500 FUME HOOD ALARMS Operating and Instruction Manual 19/7/03 Model AFA 500 Built-in or Remote sensor 2 Relay inputs 1 Relay output Com port Used for alarm indication and monitoring on Fume Cupboards

More information

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations. 1 P age Ezeio v9-120317 Eze Cloud Based Monitoring Systems. Created by Intech Instruments Ltd December 2014 Important Supplementary Manual to the main Ezeio manual. Ezeio Controller and the 2400-A16 input

More information

SCAN200E USER S MANUAL

SCAN200E USER S MANUAL SCAN200E USER S MANUAL Code No. 2071 1052 rev. 1.4 Code No. 2071 1052 Rev. 1.4 Page 2/16 SCAN200E User s Manual Foreword This manual is for SCAN200E Controller running software version 2.03 or later. We

More information

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi 50 (P/N 10-071) is a state-of-the-art true intelligent digital peer-to-peer modular suppression control system.

More information

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X X testregistrierung Type Web server, also for mobile devices Zone modules Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X-AIRCONTROL zone

More information

Air heater/cooler in combination with ground source heat pump

Air heater/cooler in combination with ground source heat pump Swegon CASA Air heater/cooler in combination with ground source heat pump Installation, operation and maintenance instructions for design engineers, installation engineers and service personnel SDHWM_c_EN

More information

Model 8682-KET Sequenced Offset (Flow Tracking) and Static Pressure Controller with Dual Exhaust Modulation for Temperature Control

Model 8682-KET Sequenced Offset (Flow Tracking) and Static Pressure Controller with Dual Exhaust Modulation for Temperature Control Critical Environments Model 8682KET Sequenced Offset (Flow Tracking) and Static Pressure Controller with Dual Exhaust Modulation for Temperature Control Manual Supplement Contents of this manual supplement

More information

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 00 m /h COMFORT 00 The Comfort 00 is a ventilation unit suitable for central ventilation

More information

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option SM3000 Videographic Recorder User Guide (RTU) Communications Option ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow

More information

MB Therma-Fuser Standalone Motorized Disc VAV Diffuser

MB Therma-Fuser Standalone Motorized Disc VAV Diffuser MB Therma-Fuser Standalone Motorized Disc VAV Diffuser Models: MB-M MB-S MB-D Master with sensor and controller Slave with controller to follow master Drone with controller for 3rd party control Therma-Fuser

More information

DC 60 & DM 60 displays

DC 60 & DM 60 displays USER MANUAL DC 60 & DM 60 displays BALTIC FLEXAIR ENERGY AIRCOOLAIR COMPACTAIR FLATAIR (& Inverter) AQUALEAN DC60-DM60-IOM-1310-E www.lennoxemea.com Summaries 1 Display DC60 1.1 Introduction... 2 1.2

More information

200i/KN2, KN4 Firmware Revision Sheet

200i/KN2, KN4 Firmware Revision Sheet 200i/KN2, KN4 Firmware Revision Sheet Revision 2.9 Special Release 1- November 2013 1. Added an external boiler Failsafe feature. The J6 Analog Output can be used to enable a SSR which can be used to enable

More information

Air Comfort. Installation instructions (English) A

Air Comfort. Installation instructions (English) A Air Comfort Installation instructions (English) WWW.BRINKAIRFORLIFE.NL 614788-A This appliance may be used by children as of 8 years of age, persons of reduced mental or physical capacities and those of

More information

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems Honeywell Life Safety Iberia C/Pau Vila 15-19; 08911 Badalona Barcelona T. 902 03 05 45; Internacional:+34932424236 www.honeywelllifesafety.es infohlsiberia@honeywell.com ibox Modbus Server Gateway for

More information

Swegon Home Solutions CASA. R3 Smart. Installation, commissioning and maintenance instructions. R3_f_EN-t

Swegon Home Solutions CASA. R3 Smart. Installation, commissioning and maintenance instructions. R3_f_EN-t Swegon Home Solutions CASA R3 Smart Installation, commissioning and maintenance instructions R3_f_EN-t Contents Technical Guide for design engineers, installation engineers and service personnel The section

More information

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide Controllers Centralization of Access Control Devices Made Easy Installer Guide CONTENTS 1 INTRODUCTION 3 The Overview of Hardware 5 The Overview of Installation & Communications 7 Installations with door

More information

SUSA CONTROL AND MONITORING UNIT. Description INSTALLATION INSTRUCTIONS

SUSA CONTROL AND MONITORING UNIT. Description INSTALLATION INSTRUCTIONS INTLLTION INTRUCTION U CONTROL ND MONITORING UNIT Valid from week of manufacture 2015.10 and serial number 150800281.0 Description The U is a control and monitoring unit designed to control various types

More information

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort. OVERVIEW and SYSTEM GUIDE Swegon CASA Residential ventilation for optimal operating economy and the greatest comfort. www.swegon.com Swegon your system supplier Supply air diffuser Vapour barrier for duct

More information

Swegon Home Solutions CASA. W9 Smart. Installation, commissioning and maintenance instruction. W9_e_EN-t

Swegon Home Solutions CASA. W9 Smart. Installation, commissioning and maintenance instruction. W9_e_EN-t Swegon Home Solutions CASA W9 Smart Installation, commissioning and maintenance instruction W9_e_EN-t Contents Installation, operation and maintenance instructions for design engineers, installation engineers

More information

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-35 GEBRAUCHSANWEISUNG DEUTSCH SEITE with external sensor

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-35 GEBRAUCHSANWEISUNG DEUTSCH SEITE with external sensor with external sensor OPERATION MANUAL ENGLISH PAGE -35 GEBRAUHSANWEISUNG DEUTSH SEITE 36-70 ontent Page ) Display explanations 3 2) State of delivery / Sleep Mode 4 3) Gathering information prior to device

More information

Reference Guide for Microprocessor Controller

Reference Guide for Microprocessor Controller Document 483586 Microprocessor Controller for Dedicated Outdoor Air System Reference Guide for Microprocessor Controller Please read and save these instructions for future reference. Read carefully before

More information

SIRe Competent Air Curtains Water With quick guide. SIReAC. For wiring diagram, please see p Original instructions

SIRe Competent Air Curtains Water With quick guide. SIReAC. For wiring diagram, please see p Original instructions Original instructions SIRe Competent Air Curtains Water With quick guide SIReAC SE... 2 GB... 19 DE... 36 FR... 54 For wiring diagram, please see p.71-73 For more languages, please see www.frico.se SIRe

More information

Primo Hotel. General. Indoor climate units for hotel rooms

Primo Hotel. General. Indoor climate units for hotel rooms Indoor climate units for hotel rooms General Primo Hotel indoor climate unit Ceiling-mounted indoor climate units for ventilation, cooling and heating High capacity; occupies little space Dry system without

More information

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery. PRODUCT DATA COMBI 300 POLAR BY NILAN Ventilation with passive & active heat recovery Domestic Passive heat recovery Active heat recovery Ventilation < 350 m 3 /h Comfort heating Comfort cooling COMBI

More information

Modbus TCP Register List GreenManager for GreenMaster C-F Valid for firmware version 2.0 or later

Modbus TCP Register List GreenManager for GreenMaster C-F Valid for firmware version 2.0 or later Modbus TCP Register List GreenManager for GreenMaster C-F Valid for firmware version 2.0 or later Overview Modbus can access single adresses or multiple addresses simultaneously; either reading or writing

More information

Comfort Air Curtains with in-built dynamic advertising

Comfort Air Curtains with in-built dynamic advertising Comfort Air Curtains with in-built dynamic advertising www.stavoklima.eu Li-DR Air Curtains Li-DR Contents Contents: page Introduction... 2 Air Curtains Li with in-built dynamic advertising (DR)... 3 Description

More information

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm METAL SHARK COMBI Flat metal detector for textile and non-woven products Metal sensitivity from Fe 0,3 mm METAL SHARK - The new generation in metal detecting technology Introducing the METAL SHARK presenting

More information

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-36 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-36 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor with internal sensor OPERATION MANUAL ENGLISH PAGE -36 GEBRAUHSANWEISUNG DEUTSH SEITE 37-7 ontent Page ) Display explanations 3 2) State of delivery / Sleep Mode 4 3) Gathering information prior to device

More information

SCC1 GROZONE CLIMATE CONTROLLER The Simple One Series...

SCC1 GROZONE CLIMATE CONTROLLER The Simple One Series... SCC1 GROZE CLIMATE CTROLLER The Simple One Series... PRODUCT OVERVIEW ADVANCED USER GUIDE Advanced User Guide - Table of Content Section Content Page 1 Temperature Control with a Fan Low Temp and High

More information

OPERATING MANUAL UTY-RNNYM P/N English

OPERATING MANUAL UTY-RNNYM P/N English OPERATING MANUAL English UTY-RNNYM P/N9373329206-04 OPERATING MANUAL CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION... 3 OPERATION... 4 TIMER FUNCTIONS... 6 ON/OFF TIMER... 6

More information

Briza Line. Digital Display Unit (Room Thermostat) Model BLC 13-RS Wall Mounting Cat Model BLC 33-RS Semi Flush Mounting Cat.

Briza Line. Digital Display Unit (Room Thermostat) Model BLC 13-RS Wall Mounting Cat Model BLC 33-RS Semi Flush Mounting Cat. Briza Line Digital Display Unit (Room Thermostat) Model BLC 13-RS Wall Mounting Cat. 1099482 Model BLC 33-RS Semi Flush Mounting Cat. 1099483 Operation and Applications Manual MADE IN ISRAEL Page 1 of

More information

Reference Guide for Microprocessor Controller

Reference Guide for Microprocessor Controller Document 482641 Microprocessor Controller for Make-Up Air Products Reference Guide for Microprocessor Controller Please read and save these instructions for future reference. Read carefully before attempting

More information

Swegon CASA. duct coils for heating. the supply air

Swegon CASA. duct coils for heating. the supply air Swegon CASA the supply air duct coils for heating Instructions for installation, operation and maintenance For design engineers, installation engineers and service personnel SDHW_c_EN m ! Important information

More information

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products Document 475595 Microprocessor Controller for Tempered Air Products Reference Guide for the Microprocessor Controller Please read and save these instructions. Read carefully before attempting to operate

More information

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes 50-120 1 General The heat exchanger control system is a control system for 380 W step motors

More information

ADRIATIC VF. Active chilled beam with cooling, heating and ventilation QUICK FACTS

ADRIATIC VF. Active chilled beam with cooling, heating and ventilation QUICK FACTS Active chilled beam with cooling, heating and ventilation QUICK FACTS The ADRIATIC VF is a chilled beam with integrated recirculated air opening in the face plate. Air is discharged into the room along

More information

RACK MONITORING SYSTEM - RAMOS Ultra

RACK MONITORING SYSTEM - RAMOS Ultra CONTEG DATA SHEET version: 9-05-0 COMPLEMENTARY SYSTEMS RACK MONITORING SYSTEM marketing@dafnia.com www.dafnia.com ABU DHABI UAE +97 55575 DUBAI JAFZA +97 4 5995 +97 4 8840 MUSCAT DOHA OMAN +968 4 75005

More information

CLEVER CONTROL Version: V3

CLEVER CONTROL Version: V3 CLEVER CONTROL Version: V3 INSTALLATION AND FUNCTIONING MANUAL USER AND BASIC VERSION Please, read these instructions carefully before attempting installation SECURITY ADVISE SIMBOLS Attention, Danger,

More information

VCM-X / RNE Controller Operator Interface SD Technical Guide

VCM-X / RNE Controller Operator Interface SD Technical Guide VCM-X / RNE Controller Operator Interface SD Technical Guide VCM-X Controller Code: SS1026 VCM-X E-BUS Controller Codes: SS1030, SS1032, SS1033, SS1034 RNE Controller Code: SS1045 VAV/Zone Controller Code:

More information

TCM-2 Thyristor Control Module DATA SHEET

TCM-2 Thyristor Control Module DATA SHEET TCM-2 Thyristor Control Module TCM-2 Thyristor DATA DATA SHEET Control Module DATA SHEET Alarm panels Type Compact Q96 design Extremely easy push-button programming (no jumpers or the like) Individual

More information

Fridge-tag 2 E OPERATION MANUAL ENGLISH PAGE 1-36 MODE D EMPLOI FRANCAIS PAGE with internal sensor

Fridge-tag 2 E OPERATION MANUAL ENGLISH PAGE 1-36 MODE D EMPLOI FRANCAIS PAGE with internal sensor with internal sensor OPERATION MANUAL ENGLISH PAGE -36 MODE D EMPLOI FRANAIS PAGE 37-7 ontent Page ) Display explanations 3 2) State of delivery / Sleep Mode 4 3) Gathering information prior to device

More information