OPERATING MANUAL OF SLIDING GATE TURNSTILE TPW-331EGS

Size: px
Start display at page:

Download "OPERATING MANUAL OF SLIDING GATE TURNSTILE TPW-331EGS"

Transcription

1 OPERATING MANUAL OF SLIDING GATE TURNSTILE TPW-331EGS

2 Contents 1 General Descriptions Definitions Sliding Gate Turnstile Passing Modes Safety Precautions Product Structure Mechanical System Electric System The Working Principle Of The Turnstile System Product Installation, Inspection And Tests Product Installation Product Status Inspection Product Function Tests Power On Self Test Function Test Normal Passing Test IN & OUT Direction Passing Modes Test Intelligent Linkage Alarm Test Anti-clamping Function Test Emergency Escape Function Test Product Usage Sliding Gate Turnstile Single Directional Passing... 11

3 7.2 Sliding Gate Turnstile Single Directional Continuous Passing Sliding Gate Turnstile Bi-directional passing Product Cleaning And Maintenance Daily Cleaning Product Regular Maintennance Product Common Troubles And Trouble Shooting Indicator Lights Failure System Power Failure Appendix... 20

4 1 General Descriptions Intelligent full height sliding gate turnstile TPW-331EGS is with circular arc structure, which is in beautifully shaped; pursuit the perfect unity of art, fashion and security; the housing made of stainless steel is durable; the mechanism modules are imported from international top brands DC brushless motors and precise positioning encoder, so as to make sure the wing gate can stretch quickly and accurately, stably and quietly, with low-power consumption, energy conservation and environment protection. TPW-331EGS is equipped with the dry contact signal input interface, RS485/RS232 interface, TCP/IP interface (optional), compatible with all kinds of access controllers. It is suitable for commercial buildings, government buildings, financial institutions, clubs and other high-end indoor applications. TPW-331EGS has been strictly tested before leaving the factory. But to ensure the safe and reliable operating of the product, users are recommended to read the manual carefully before operating so as to avoid improper operation and damage to the interests of users. 2 Definitions 2.1 Sliding Gate Turnstile The sliding gate turnstile consists of housing and two movable flaps. The flaps is retractable achieving the purpose of stopping or releasing. According to different combination ways of mechanism, the sliding gate turnstile can be divided to be single-mechanism sliding gate turnstile and dual-mechanism sliding gate turnstile. Single-mechanism sliding gate turnstile only one mechanism is equipped with one housing cabinet (as shown in Figure 2.1-1). Dual-mechanism sliding gate turnstile two independent mechanisms are equipped with one housing cabinet (as shown in Figure 2.1-2).

5 Figure Single-mechanism sliding gate turnstile Figure Dual-mechanism sliding gate turnstile According to the number of lane, the sliding gate turnstile can be divided to be single-lane sliding gate turnstile and multi-lane sliding gate turnstile. Single-lane sliding gate turnstile It consists of two single-mechanism sliding gate turnstile (as shown in Figure 2.1-3). Multi-lane sliding gate turnstile It consists of two single-mechanism sliding gate turnstile and multiple dual-mechanism sliding gate turnstile (as shown in Figure 2.1-4). Figure Single-lane sliding gate turnstile Figure Multi-lane sliding gate turnstile 2.2 Passing Modes Controlled mode: It is the default standby mode of turnstiles. When a valid open signal is given, the turnstile poles open to allow pedestrians to pass through. The valid open signals are manual open button signal and access control board open signal. Free passing mode: When a valid open signal is given, the turnstile open and pedestrians can pass through freely. The valid open signals are manual open button signal, access control board open signal, and infrared sensor open signal Forbidden passing mode: When a valid open signal is given, the turnstile don t open and pedestrians are not allowed to pass through.

6 3. Safety Precautions Although a series of testing have been carried out before shipment and the turnstile can run TPW-331EGS consists of mechanical system and electrical system. Its outline dimensions are shown as Figure 4 below. safely and stably, users should perform proper installation and debugging strictly in accordance with the operating manual before using the turnstile. Manufacturers don't take any responsibility because of improper operation or human damage. Before installation, please pay attention to the following safety precautions: Only professional electricians and technicians received electrical training can be engaged in the electrical 220VAC electrical connection operation. It is prohibited to install the turnstile without suitable foundation. During maintenance, cut the external system power supply off (such as access control, visitor system, ticketing system, etc.). A leakage switch or other current control operating devices is necessary. The connection operation of the turnstile must comply with the attached wiring diagram. Before using the turnstile, ensure that the turnstile functions test is qualified. During maintenance, please check whether the bolt is fastening. When the turnstile system is powered on, charged components such as switching power supply, resistors, lamps shall not be touched as the high temperature might cause skin burning. It is forbidden to apply heavy force on the turnstile. Otherwise, there will be unnecessary damage. It is recommended to separate the turnstile with other equipment power supply interface; otherwise the turnstile might be damaged due to the mutual interference between the equipment. Not equipped with explosion-proof device, the equipment is not allowed to use in an inflammable and explosive. However, it is optional for the users to purchase other type for the purpose.

7 Product Structure Front view 1610 Side view Figure Mechanical System The mechanical system of the turnstile consists of housing cabinet and mechanism. The housing cabinet is shown as Figure 4.1. It consists of card swiping panel, status indicator panel, direction indicator panel, infrared sensor panel, glass panel and housing. The mechanism consists of motor reducer, encoder and flap, etc.. Flap Direction indicator Card-swiping panel Passage status indicator Infrared sensor Figure 4.1

8 4.2 Electric System The electric system of the turnstile consists of main control board (see Appendix A1), slave control board(see Appendix A2),motor control board (see Appendix A3), infrared sensor, status indicator light, direction indicator light, buzzer and power module. The counter, sound-light alarm device and access control system are optional. 5 The Working Principle Of The Turnstile System (1) Turn on the turnstile system power; the system will perform power on self test. The buzzer will alarm for prompting. After the alarm prompting, the system goes into the standby mode and flap will be closed. (2) Users provide valid open signals for IN/OUT direction (access system swiping-card open signal and turnstile system open button signal) to main control board. (3) After the turnstile main control board receives valid open signal for IN/OUT direction, it sends control signal to motor control board, then the flap will open to let users to pass through. (4) After user finishes passing through, the main control board sends control signal to motor control board; swing gates are locked and the system enters standby mode. (5) If users don t provide valid open signal and then go into the turnstile to push flap, the system will lock the gate to forbid passing, at the same time the buzzer will alarm until users revoke illegal intervention. 6 Product Installation, Inspection And Tests 6.1 Product Installation (1) Prepare necessary tools for installation and choose the auxiliary parts according to the packing list. (2) Confirm the system constitution and operating modes. Get ready to install after finishing system planning. (3) Drill holes after confirming the positions. Pre-bury (N+1)*4 M12 expansion bolts as shown in Figure 6.1. Note: N means the lane quantity.

9 A A Expansion Bolt 850 Section A-A # Concete Φ100 cable hole Ground Installation & Fixed Drawing Installation steps of the expansion bolts: 1. Choose an alloy bit which is matching with the outside diameter of the expansion bolts. Drill the holes according to the length of the expansion bolts. Drilling holes to the required depth of the installation will be ok. Then please clean up the holes. 2. Install flat washers, spring washers and nuts. Screw nuts to the end of the bolts so as to protect the screw thread, and then insert the expansion bolts to the holes. 3. Turn the spanner until the washers are flush with the fixed Objects. If there re no special requirements, user can tighten up by hand and then screw for 3 to 5 turns by spanner φ16 use M12X100mm expansion bolts to fix on the ground 110 Figure 6.1 (4) Put strong/weak cables into the 3/4 PVC tube respectively, and bury them to the suitable positions. (5) Move the housing cabinets respectively to the installing positions, making them align with anchor bolts. (6) Check the system structure and operating modes. (7) Open the housing cabinet and choose one turnstile as a reference (It is recommended to choose the middle unit as a reference). Respectively align the drill holes of the bolts on the chassis with the anchor bolts and then tighten the nuts tentatively. (8) Open the adjacent housing cabinet. Respectively align the drilling holes of the bolts on the chassis with the anchor bolts according to the above referenced proper arrangement of turnstile online and tighten the nuts tentatively. (9) Connect the power wires, control wires as well as the ground wires properly according to the wiring diagram.

10 (10) After the function debugging is checked OK, tighten the anchor bolts and nuts. Note 1 The depth of the PVC tubes buried shall be more than 60mm. The height above the ground shall be more than 50mm. And the PVC tube shall be bent return so as to avoid the water falling in. 2 All the above operations should be carried out when power off. And please make sure the ground wires of the system is connected correctly, properly and firmly. Please refer to the TPW-331EGS foundation mounting diagram enclosed with the box for detailed 6.2 Product Status Inspection It is required to check the turnstile status after it is properly installed. Detailed procedures are as below: (1) Check the proper wiring among all electric components. Details please refer to Appendix. (2) After the wiring are checked OK, connect the turnstile to power. (3) After the turnstile finishes power on self-checking, both flaps should move back and forth and buzzer will alarm for prompting. After the alarm prompting, flaps should be closed. Please refer to the detailed passageway status in Table 6.2 sliding gate turnstile passing model working status table Table 6.2 sliding gate turnstile passing model working status table Turnstile Opening The direction indicator light The status indicator light (Subject to the right hand) (Subject to the right hand) Passing Mode Status IN & OUT Controlled Passing When standby, the (1) When standby, IN&OUT turnstile is closed; after the direction indicator turns red. turnstile receives a valid open signal, the turnstile gate opens and user can pass through normally. IN/OUT Controlled Passing, When standby, the turnstile is closed; after the (2)When IN/OUT direction receives a valid open signal, IN/OUT direction indicator turns green and OUT / IN direction indicator turns red. (1)When standby, (1)When standby, IN&OUT status indicator turns red. 2 When IN/OUT direction receives a valid open signal, IN/OUT status indicator turns green and OUT / IN status indicator turns red. IN&OUT When standby, the controlled direction indicator turns red. direction and forbidden direction (2)When the controlled direction receive a valid open signal, the

11 OUT / IN Forbidden passing controlled direction receives a valid open signal, the status indicator of the controlled receives a valid open direction indicator turns green; the direction turns green, the status direction indicator of the forbidden indicator direction turns red. direction turns red. signal, the turnstile opens and user can pass through of the forbidden (3)When the forbidden direction of normally. After the the turnstile receives a valid open forbidden direction signal, both the controlled and the forbidden direction indicator turn receives a valid open signal, the turnstile doesn t red. open. When IN / OUT Controlled Passing, OUT / IN Free Passing standby, the (1)When standby, the direction turnstile is closed; after the indicator of the Free Passing IN/OUT direction receives direction turns green; the direction a valid open signal, the turnstile opens and user can pass normally. through indicator of the forbidden direction turns red. (2)When IN/OUT direction receives a valid open signal, IN/OUT direction indicator turns green; OUT/IN direction indicator 1 When standby, the direction indicator of IN & OUT direction turns green; 2 When IN/OUT direction receives a valid open signal, IN/OUT direction indicator turns green; OUT/IN direction indicator turns red. turns red. (4) Check whether the turnstile working mode is in accordance with the user requirements. Please refer to Table 6.2 for details. If the direction indicator is abnormal, please refer to Chapter 9<The common trouble shooting of products> or contact the manufacturer. (5) Check whether the infrared detectors of each lane do work normally. Please check one by one, when you block one pair of infrared detectors, the corresponding infrared lights of main control board should be off. If the lights are abnormal, please refer to Chapter 9<The common trouble shooting of products> to check or contact the manufacturer. (6) Check the running status of the flaps: When standby, use the test buttons to provide an open signal. The flaps will be rotating smoothly and returning normally when being pushed. If the running status of the flaps is abnormal, please contact the manufacturer.

12 6.3 Product Function Tests After checking the turnstile status, it is also required to test the turnstile functions. Detailed tests include: power on self test function test, normal passing test, IN & OUT direction passing modes test,intelligent linkage alarm test, anti-clamping function test and emergency escape function test Power On Self Test Function Test After power on, the sliding gate turnstile should move back and forth and buzzer will alarm for prompting. After the alarm prompting, flaps should be closed Normal Passing Test When standby, the flaps are closed. Using the test button of the turnstile to provide an valid open signal, the flaps open. Within the allowed passing time (usually about 5S), user can pass through normally. During the passing, buzzer shouldn't alarm. After the user finishing the passing, the flaps should be locked IN & OUT Direction Passing Modes Test Set the turnstile passing models via the WORK MODE module on the control board, as shown is Figure The IN direction and OUT direction can be separately set as Controlled Passing Free / Passing / Forbidden Passing. Generally the turnstile passing modes are set as IN & OUT controlled passing (default), IN/OUT controlled passing & OUT/IN forbidden passing, as well as IN/OUT controlled passing & OUT/IN free passing. Observe whether the turnstile poles status and the direction indicator are normally under different working modes. If they work normally, then the passing modes can switch normally. If not, the mode switching function is abnormal. Please refer to Table 6.2 for details.

13 IN & OUT Directions Working Mode Setting: Use the R & L buttons to switch the working modes of IN & OUT directions: L Switch the working modes of IN direction (controlled-free-forbidden, switched in loop) R Switch the working modes of OUT direction (controlled-free-forbidden, switched in loop) Passing mode indicator lights show the working mode of the corresponding direction: L1 Green When the light is on, the IN direction is at free passing mode. L2 Red When the light is on, the IN direction is at forbidden passing mode. L3 Yellow When the light is on, the IN direction is at controlled passing mode. R1 Green When the light is on, the OUT direction is at free passing mode. R2 Red When the light is on, the OUT direction is at forbidden passing mode. R3 Yellow When the light is on, the OUT direction is at controlled passing mode. Figure Intelligent Linkage Alarm Test During debugging buzzer should alarm for prompting when the turnstile power on self test, pedestrians intrusion, pedestrians reverse passing and tailgating, as shown is figure Anti-intrusion Anti-reverse pass Intelligent linkage alarm Power on Anti-tailgating pass Self-check when power on Figure 6.3.4

14 6.3.5 Anti-clamping Function Test Infrared anti-clamping Machinery anti-clamping Machinery anti-clamping: In the process of closing, use hand to block flaps and the flaps should open automatically to prevent clamping pedestrians. Infrared anti-clamping: In the process of closing, once people or thing is detected in the anti-clamping area(the middle pair of infrared sensor), the flaps will open automatically to prevent clamping pedestrians Emergency Escape Function Test Press the emergency escape button (red button),the flaps should be open and users can pass through from both sides. 7 Product Usage When using the sliding gate turnstile, pedestrians should obey the rules of Swiping cards outside the yellow line, one person one card, forbid tailgating and reverse passing. Note: Swiping cards outside the yellow line, one person one card, forbid tailgating and reverse passing means that the pedestrians should swipe the card outside of the yellow line; each time a valid card swiped only allows one person to pass through; the next and the opposite pedestrians no swiping are forbidden to pass. 7.1 Sliding Gate Turnstile Single Directional Passing As shown is figure 7.1. When standby, pedestrians outside the yellow line a IN / OUT valid open signal to the turnstile, flaps will open and pedestrians can pass; after passing through, flaps will close and return to the hindered zero position automatically.

15 Figure 7.1 Sliding gate turnstile single directional passing 7.2 Sliding Gate Turnstile Single Directional Continuous Passing When pedestrians provide more than one open signals at the same direction, the system will memorize all the passing requests and finish in sequence. 7.3 Sliding Gate Turnstile Bi-directional passing When standby, the person A stands outside the yellow line of the IN direction and provides a valid open signal for the turnstile, the flaps open and the person A passes through. After the person A finishes passing through, the flaps close. The person B should be waiting outside of the yellow line of the OUT direction. After the person A finishes passing through, the person B stands outside the yellow line of the OUT direction and provides a valid open signal for the turnstile, the flaps open and the person B passes through. After the person B finishes passing through, the flaps close. The turnstile and the person A 's status in the passing process is shown as Figure The turnstile and the person B's status in the passing process is shown as Figure Note: For bi-directional passing, pedestrians can only swipe the card and pass through in sequence. It is not allowed that two pass through in the same or opposite direction simultaneously. The white one is the person A, the blue one is the person B. Figure Passing Process of The Person A

16 Figure Passing Process of The Person B 8 Product Cleaning And Maintenance The cleaning and maintenance of turnstiles will directly affect its service life. Therefore, it is necessary to clear and maintain regularly. 8.1 Daily Cleaning The daily cleaning and maintenance includes surface cleaning and internal cleaning. The cleaning cycle is once a week. Please refer to Table 8.1 for details. Table 8.1 Area Tools Cleaning Methods Notes ①Cut the power supply off, and use the clean soft cloth ① Clean and soft cloth Stainless Steel Housing ②Stainless steel cleaner polish, watered alkalescent detergent (Proportion7:1) to clean the dust on surface. Spray the stainless steel cleaner polish on the clean cloth, and then wipe along the lines of the brushed stainless steel surface until it s clean and bright again. ②Use the cloth to clean the bottom and the surrounding Please do not use water, strong alkaline solvent or acidic solvent to clean. ground; Make sure the bottom is dry, and without any water. ① Clean and soft cloth Organic Glass ① Clean the ordinary floating dust Wipe the surface of Please do not use ②Clean solvent (special the organic glass gently with a clean cloth moistened organic clean with solvent, or spray the organic glass with a solvent, 1% of Soapy sprayer, then wipe with a clean cloth gently, and Medical water, finally wipe with a dry cloth. alcohol, glass Glass cleaning liquid "glass of water", ②Clean glue dust: wipe with a cotton moistened with little 30% of medical alcohol, diesel oil, if you don t have the diesel oil, you can handle Diesel and other weakly it with the method of cleaning the ordinary floating dust, Acetone-contai ning solvents, and strong alkaline solvent or acidic solvent to clean.

17 basic or weakly acidic watered medical alcohol (Proportion7:1). solvent ) ③ Small scratches treatment of the organic glass s surface: wipe the scratches gently for about 5 minutes with a cotton painted little toothpaste. ① Clean and soft cloth ②Clean solvent (Glass cleaning liquid "glass of Tempere water", 1% of Soapy d Glass water, 30% of medical alcohol, Vinegar, brine and other weakly basic or weakly acidic solvent ) ①Clean the ordinary floating dust wipe the surface of the organic glass gently with a clean cloth moistened with solvent, or spray the organic glass with a sprayer, then Please do not use strong wipe with a clean cloth gently, and finally wipe with a dry alkaline solvent cloth. or ② Clean stubborn stains: wipe with a clean cloth moistened with 30% of medical alcohol or warm vinegar. acidic solvent to clean. ③Clean surface frost: wipe with a clean cloth moistened with 30% of medical alcohol or brine. ① Disconnect to power and then open the maintenance door. Use the blow gun to remove the internal dust and fines. The mechanical core, boards, switching power, ① Clean soft cloth Internal cleaning ② Air blow gun ③Stainless steel cleaner polish gaps and bottom need to be cleaned specially, so as to ensure it s clean and dry. Don t use the ② Use the cloth to wipe the dust inside the cabinet and dust catcher or that on the mechanical parts. air-heater ③ Dip another clean cloth with suitable amount of stainless steel cleaner polish to wipe along the lines of the brushed stainless steel surface of the access door until it s clean and bright again. 8.2 Product Regular Maintenance Please pay attention to the following: 1 Non-professionals are not allowed to open the turnstile housing cabinet to perform tests, maintenance or product services; 2 It is forbidden to use hard objects to clean the turnstile surface, or it will be easily scratched. 3 It is forbidden to use water to clean, or it will cause the short circuit of the electric components

18 and affect the normal usage of the turnstile. 4 It is required to check the connections of each interface on the mechanism periodically, so as to avoid the looseness of the parts. 5 It is required to use lubricants to lubricate the mechanism parts periodically. 6 It is required to check the sockets and wiring connections periodically so as to ensure the stability of the wiring connections. 7 It is required to check the grounding connection of the electric system periodically so as to avoid electric leakage. 8 After finishing the maintenance, please connect the turnstile system to power and close the maintenance doors. 9 Product Common Troubles And Trouble Shooting 9.1 Indicator Lights Failure When standby, the direction indicator light turns red (as shown in Figure 9.1-1) and status indicator light is green. The running Light (RUN) of the control board is flashing at a frequency of one time per second, as shown in Figure ; the infrared detector status indicator of the control board is often on as long as there is nothing to block the infrared detector. Under IN & OUT Controlled Passing mode, when IN/OUT direction receives a valid open signal, IN/OUT direction indicator turns green, OUT/IN direction indicator turns red. IR sensors status indicator lights Direction indicator Main control board running (RUN) Status indicator Figure9.1-1 Direction Indicator & Status Indicator Figure9.1-2 IR sensors status Indicator lights & Main control board running light (RUN) light

19 Indicator light failures: All the lights are off. The direction indicator light and the status indicator light are abnormal. The running Light (RUN) of the control board is not flashing. All the lights are flashing. When blocking the infrared detector, the infrared detector status indicator of the control board is still on. (1) All the lights are off. Cause Analysis: malfunction of wiring connection, power supply or main control board Troubleshooting Check whether the wiring connection and the power supply output are normal. If it is normal, then the main control board might be damaged and contact the manufacturer. If the wiring connection is abnormal, please fix the wiring connection. If the power supply is faulty, please contact the manufacturer. (2) The direction indicator and the status indicator is abnormal. Cause Analysis: malfunction of wiring connection, main control board or the direction indicator and the status indicator are damaged. Troubleshooting Check whether the wiring connection is normal, if it is abnormal, please fix the wiring connection; if the wiring connection is normal, then check whether the power supply of the direction indicator and the status indicator is normal; if normal, the direction indicator and the status indicator might be damaged; if abnormal, the main control board might be damaged, please contact the manufacturer. (3) The running Light (RUN) of the control board is not flashing. Cause Analysis: The main control board malfunctions or the toggle switch of the communication panel has been switched to UPDATE. Troubleshooting Check the toggle switch on the communication panel of the control board and make sure it is at WORK. And then restart the system. If the system still malfunctions, it proves the main control board might be faulty. Please contact the manufacturer. (4) All the lights are flashing.

20 Cause Analysis: Short circuit or the main control board is faulty. Troubleshooting Check whether there exists any short circuit. If yes, please rule out and fix the wiring connection. If no, then it proves the main control board might be faulty. Please contact the manufacturer. (5) When blocking the infrared detector, the infrared detector status indicator of the control board is still on. Cause Analysis: wiring connection of the infrared detector and the main control board, or infrared sensor malfunctions. Troubleshooting Check whether the wiring connection of the infrared detector and the main control board are normal, If it is abnormal, please fix the wiring connection. If it is normal, check whether the power supply of the infrared detector is normal; if it is normal, the infrared detector might be damaged, please contact the manufacturer. If the power supply of the infrared detector is abnormal, the control board might be damaged, please contact the manufacturer. 9.2 System Power Failure When standby, the POWER light on the main control board is normally on. As shown in Figure 9.2. Figure Power Light On The Main Control Board

21 Figure Power light LED1&LED5 on the motor control board System power failures: The V/AC power cable of the system has been connected, but not electrified. The POWER light on the main control board is not ON. The power light LED1 & LED5 on the motor control board are not on V/AC power cable of the system has been connected, but not electrified. Cause Analysis: The contact chip of the power socket is loosened or damaged; the V/AC power cables are damaged. Troubleshooting Check whether the contact chip of the power socket is loosened or damaged. If yes, please repair or replace the socket. If the power socket is normal, please rule out whether the V/AC power cable is damaged. If yes, please replace the V/AC power cable. If the V/AC power cable is normal, please check whether the leakage protection switch is working normally. If not, please replace the leakage protection switch or contact the manufacturer. If the leakage protection switch is working normally, please check whether the output voltage of the power supply module is normal and contact the manufacture with the feedback. (2) The main control board doesn t electrify and the POWER light on the control board is not ON. Cause Analysis: The switch power supply is damaged, the wiring connection between the switch power supply and the main control board is faulty, or the main control board is faulty. Troubleshooting Check whether the switch power supply is damaged. If yes, please contact the manufacturer. If it is normal, please check whether the wiring between the switch power supply and the main control board is normal. If not, please repair the wiring

22 connection. If the wiring between the switch power supply and the main control board is normal, then it is possible that the main control board is faulty. Please contact the manufacturer. (3) The motor control board doesn t electrify and the power light LED1 & LED5 on the motor control board is not ON. Cause Analysis: The switch power supply is damaged, the wiring connection between the switch power supply and the motor control board is faulty, or the motor control board is faulty. Troubleshooting: Check whether the switch power supply is damaged. If yes, please contact the manufacturer. If it is normal, please check whether the wiring between the switch power supply and the motor control board is normal. If not, please repair the wiring connection. If the wiring between the switch power supply and the motor control board is normal, then it is possible that the motor control board is faulty. Please contact the manufacturer. Note: The above shows the common failures of the products. For troubleshooting methods of more failures, please refer to the special maintenance manual of the product.

23 Appendix The turnstile main control board is shown as Figure A1; slave control board is shown as figure A2; motor control board is shown as figure A3. Figure A1 The main control board Figure A2 The slave control board

24 Figure A3 The motor control board The circuit board installation position of the turnstile is shown as Figure B1, the electrical wiring connection of the main cabinet is shown as Figure B2, the electrical wiring connection of the slave cabinet is shown as Figure B3, the control board instruction is shown as Figure B4, The wiring instructions for the external interface of main control board is shown as Figure B5. View A View D A B C D Electrical distribution of the main cabinet Electrical distribution of the slave cabinet View B Electrical distribution of the main cabinet View C Electrical distribution of the slave cabiet Figure B1 The circuit board installation position

25 L N brown blue Yellow red V3 VV+ The motor interface TPW-331EGS Main Cabinet The encoder interface L N black red V1 VV+ E1(5P) MP MP(4P) M1(8P) POWER J7 2P POWER brown blue V2 The motor control board L N yellow red VV+ POWER MD1 N NC L N Relay COM NO L N UPS L N The main control board EMO J15 S1 L N MP(4P) IN 110/220VAC L MP(4P) J15(2P) J6 J13 J14 Buzzer 2P J4 In direction status indicator(3p) J2 IR 1 3 signal interface (4P) J16 J15 J15(2P) IR sensor signal interface 5P J7 J7 2P In direction indicator light(3p) P2(4P) M-S brown M-S 1.VO3+ 2.V VO1+ 4.VO15.CAN-H 6.CAN-L blue red red black J15(2P) MASTER yellow The main control board Connect with the corresponding number of slave cabinet J1 J17 CAN(2P) Figure B2 The electrical wiring connection of the main cabinet

26 J7 J5 J15 J3 J16 S-M 1 2 Out direction status indicator(3p) Out direction indicator light(3p) brown blue red 4 yellow 6 black S-M 1.V03+ 2.VO33.VO1+ 4.V015.CAN-H 6.CAN-L The slave control board 5 white CAN Communication (2P) 3 Connect with the corresponding number of main cabinet CAN Communication(2P) The power wire of slave control board 2P J14 IR sensor input signal(4p) CAN Communication(2P) J13 CAN Communication(2P) IR sensor input signal (5P) Motor drive circuit board 6 black E2(5P) 5 red J15 yellow MD2 red 4 yellow blue 3 red brown 2 red yellow D2 1 blue M1(8P) MP The power wire of motor control board 4P D2 1.VO3+ 2.V033.V01+ 4.V015.V01+ 6.V01brown The encoder interface(5p) The motor interface (8P) TPW-331EGS The slave cabinet Figure B3 The electrical wiring connection of the slave cabinet

27 1. Infrared sensor status indication Indicating the corresponding infrared state: when the infrared is blocked, the corresponding light off Zero adjustment ZERO1: the closed position adjustment of fully automatic tripod turnstile. After pressing the ZERO1, the VALID1 lights up, manually adjust the arms to the closed position and press ZERO1 again, and the VALID1 light is off. ZERO2: The sliding gateturnstiles are invalid Working modes setting for entry and exit direction Use these two buttons can switch the working modes of entry and exit direction. L: switch the working mode of entry direction (controlled-free-forbidden, switch circularly) R: switch the working mode of exit direction (controlled-free-forbidden, switch circularly) Direction Indicator lights indicate the working modes at the corresponding direction. L1 (green): the light on means entry direction is free passing mode L2 (red): the light on means entry direction is forbidden passing mode L3 (yellow): the light on means entry direction is controlled passing mode R1 (green): the light on means exit direction is free passing mode R2 (red): the light on means exit direction is forbidden passing mode R3 (yellow): the light on means exit direction is controlled passing mode 9. Download protection lock When the turnstile needs to download and upgrade the new program, please toggle the switch to "UPDATE" position, and then download and upgrade the program through 7. (DB9) interface. 4. Reset, restart and automatically adjustment RESTART: restart the turnstile systems RESET: reset the default setting of the turnstile systems AUTOSET: the semi-auto tripod turnstiles are invalid RUN indicator light: the indicator light of running status. The light will flicker per second when the turnstile works normally. 5. Testing buttons There are three buttons on the panel can directly test the left gate open, right gate open and close the gate. OPEN_L: open gate at entry direction OPEN_R: open gate at exit direction CLOSE: The sliding gate turnstiles are invalid 6. The reset button of counter Attention! When turnstile is normally working, user must toggle the switch to the WORK position. C_L: clearing entry counting C_R: clearing exit counting 10.RS232 RS DB9 The default communication interfaces of turnstile RS232 GND: Ground RX: RS232 receiving terminal TX: RS232 transmitting terminal RS485 +: RS485 + terminal -: RS485 - terminal 1. Used for downloading and upgrading the firmware of turnstile control panel. 2. One of the default communication interfaces of turnstile 8. Turnstile dry contact control input Use the switch signals such as relay signal and buttons and so on can control turnstile s opening & closing. 11.Extend input interface Use it to achieve the extend function. 12. Ethernet Interface Ethernet communication interface can be customized. OPEN_R: entry direction open OPEN_L: exit direction open CLOSE: The sliding gate turnstiles are invalid EMO: emergency open the gate (normally open signal); the effective signal less than 1 second is the arm-dropped testing. Figure B4 The main control board instruction

28 Signal access 控制面板 Button Entrance COM open NO relay signal NC Button Exit open relay signal COM NO NC Button COM Fire relay NO signal NC Spring terminal usage 3 2 PC 1 3 Tool: straight screwdriver The specification of used cable 0.3mm²~1.0mm² The length of cable after removing the insulating layer 5mm~8mm 1 use the straight screwdriver to press vertically and open the wiring access port; 2 Then insert the cable; 3 loosen the straight screwdriver and clamp the cable to finish the connection. Figure B5 The wiring instructions for the external interface of control board

Intelligent Swing Gate Turnstile Operating Manual CPW-322CS

Intelligent Swing Gate Turnstile Operating Manual CPW-322CS Intelligent Swing Gate Turnstile Operating Manual CPW-322CS C O N T E N T S 1. General Descriptions...1 2. Definitions... 1 2.1 Swing Gate Turnstile... 1 2.2 Passing Modes... 2 3. Safety Precautions...3

More information

TPW-900ETS01. Product Manual. Intelligent Swing Gate Turnstile

TPW-900ETS01. Product Manual. Intelligent Swing Gate Turnstile TPW-900ETS01 Intelligent Swing Gate Turnstile Product Manual Contents Product Description... 1 Structure Chart... 2 Dimension Figure Unit mm... 2 Product Parameters... 3 Product Function... 3 Custom-made

More information

Tripod Turnstile CPW-450BF. Product Manual V3.2

Tripod Turnstile CPW-450BF. Product Manual V3.2 CMOLO The World Famous Leader Of Intelligent Pedestrian Access Control Tripod Turnstile CPW-450BF Product Manual V3.2 Contents Product Description... 1 Structure Chart... 2 Dimension Figure(Unit:mm)...

More information

Column swing gate turnstile CPW-321ASP

Column swing gate turnstile CPW-321ASP Column swing gate turnstile CPW-321ASP Product Manual Concise high efficient & fashionable Product Description: The passage consists of two units of CPW-321ASP by default. Single-gate passage by one unit

More information

SERIES 4000 AUTO GATE MANUAL

SERIES 4000 AUTO GATE MANUAL SERIES 4000 AUTO GATE MANUAL Website: www.turnstilesecurity.com Page 1 of 27 Table of Contents 1.0 Warranty... 4 2.0 Safety... 5 2.1 Designated Use... 5 2.2 Areas of Application... 5 2.3 Warning Notes...

More information

InBio X60 Series Access Control Panel User Manual

InBio X60 Series Access Control Panel User Manual InBio X60 Series Access Control Panel User Manual Version: 1.4 Date: Nov., 2015 About This Manual This manual introduces the installation connection and user manual of the InBio X60 Series Access Control

More information

Installation Guide for inbiox60 Series Access Control Panel

Installation Guide for inbiox60 Series Access Control Panel Installation Guide for inbiox60 Series Access Control Panel Version: 1.0 Date: April, 2011 About This Manual This manual is a guide to installation and connection of the inbiox60 series access control

More information

OPTICAL TURNSTILE SYSTEM

OPTICAL TURNSTILE SYSTEM OPTICAL TURNSTILE SYSTEM Installation Instructions OTS-WNG UNPACK TURNSTILES. Remove the bolts at the ends of the turnstiles to separate from the skids and place turnstiles on the floor. With a box knife

More information

SCR100 User Manual. Version:1.1 Date:Dec 2009

SCR100 User Manual. Version:1.1 Date:Dec 2009 SCR100 User Manual Version:1.1 Date:Dec 2009 Introduction: This document mainly introduces the installations and connections of SCR100 products, and the brief operations about attendance software. Important

More information

ASL T6 / T7 / T8 / T9 FLOOR GRINDING MACHINES MANUAL

ASL T6 / T7 / T8 / T9 FLOOR GRINDING MACHINES MANUAL ASL T6 / T7 / T8 / T9 FLOOR GRINDING MACHINES MANUAL 1 Contents Preface 3 1.1 Safety Guide 4 1.2 Precautions 4 Chapter II 5 Purchase Check, Technical Parameter and Product Description 5 2.1 Purchase Check

More information

ES860 OPTICAL TURNSTILE INSTALLATION AND OPERATION MANUAL PRESENT CARD

ES860 OPTICAL TURNSTILE INSTALLATION AND OPERATION MANUAL PRESENT CARD ES860 OPTICAL TURNSTILE INSTALLATION AND OPERATION MANUAL To accommodate unique architectural arrangements of these bollards, their design and construction will allow their being installed in an arc shape,

More information

SpeedStile FP. Full-Panel Speed Gate with Sliding Glass Barrier

SpeedStile FP. Full-Panel Speed Gate with Sliding Glass Barrier The SpeedStile FP continues to be one of Gunnebo s most popular and sought after optical turnstile products. The SpeedStile FP can be designed in a wide variety of finishes such as stainless steel, brass,

More information

5 Inch Speed Dome Installation Manual V2.0.0

5 Inch Speed Dome Installation Manual V2.0.0 5 Inch Speed Dome Installation Manual V2.0.0 2010-01 1 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to

More information

KT-100 Door Controller

KT-100 Door Controller WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully

More information

4040 FM 535 F :

4040 FM 535 F : OVERVIEW OPTICAL TURNSTILE SYSTEM HALF HEIGHT BARRIER TURNSTILES MODEL OTS-HHB-6 The OTS-HHB monitors through-beam infrared sensors, access control contacts, and barrier posion sensors to control the moon

More information

SU2000-SM. model OPTICAL TURNSTILES DESCRIPTIVE SPECIFICATIONS TYPICAL INSTALLATION SITES COMMON APPLICATIONS ALVARADOMFG.COM

SU2000-SM. model OPTICAL TURNSTILES DESCRIPTIVE SPECIFICATIONS TYPICAL INSTALLATION SITES COMMON APPLICATIONS ALVARADOMFG.COM model The Supervisor 2000-SM is our thinnest barrier-free turnstile. Its compact form is well suited for applications where space is at a premium. COMMON APPLICATIONS Employee and Visitor Access Control

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

FMJ-1600-II-WARM Ving 63" Full - auto Wide Format Roll Heat Assisted Cold Laminator with Stand USER MANUAL

FMJ-1600-II-WARM Ving 63 Full - auto Wide Format Roll Heat Assisted Cold Laminator with Stand USER MANUAL FMJ-1600-II-WARM Ving 63" Full - auto Wide Format Roll Heat Assisted Cold Laminator with Stand USER MANUAL I. Specifications Heating Mode: Upper roller heating Heating power: 1500W Rated Power: 16A II.

More information

EduCam360-B. Fisheye Panorama Network Camera Manual

EduCam360-B. Fisheye Panorama Network Camera Manual EduCam360-B Fisheye Panorama Network Camera Manual Table of Contents 1 Important Safeguards and Warnings... 3 1.1 Electrical safety... 3 1.2 Environment... 3 1.3 Operation and Daily Maintenance... 4 1.4

More information

Quick Start Guide. 4MP Vandal Dome Fixed Lens IP Camera O4D1

Quick Start Guide. 4MP Vandal Dome Fixed Lens IP Camera O4D1 Quick Start Guide 4MP Vandal Dome Fixed Lens IP Camera O4D1 Version 1.1.1 Welcome Thank you for purchasing this Network camera! This manual is designed to be a reference tool for your system. Please read

More information

Preparations MT-RT1806. Cleaning & Maintenance. Precautions

Preparations MT-RT1806. Cleaning & Maintenance. Precautions Preparations Cleaning & Maintenance 1. Use general liquid detergent and soft cloth for daily cleaning. Don't use detergent that with acetone or ammonia. Disinfector with formic acid and formaldehyde is

More information

Massage Bathtub Instructions of Installation. MODEL: TOCOA SIZE: 1380*1380*610mm

Massage Bathtub Instructions of Installation. MODEL: TOCOA SIZE: 1380*1380*610mm Massage Bathtub Instructions of Installation MODEL: TOCOA SIZE: 1380*1380*610mm Dear Customer, Thank you for choosing our product. For your safe concern, please take a few minutes to read this manual before

More information

FIRERAY 5000 range USER GUIDE

FIRERAY 5000 range USER GUIDE FIRERAY 5000 range USER GUIDE 0044-003-04 IMPORTANT PLEASE NOTE: The beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal.

More information

OPTICAL TURNSTILE SYSTEMS

OPTICAL TURNSTILE SYSTEMS OPTICAL TURNSTILE SYSTEMS Barrier Arm Turnstiles Model No. OTS-ARM OVERVIEW The OTS-SS-ARM monitors through-beam infrared sensors, access control contacts, and arm position sensors to control the motion

More information

Massage Bathtub Instructions of Installation. MODEL:MT-NR1502(1504) SIZE:1500*1500*610mm

Massage Bathtub Instructions of Installation. MODEL:MT-NR1502(1504) SIZE:1500*1500*610mm Massage Bathtub Instructions of Installation MODEL:MT-NR1502(1504) SIZE:1500*1500*610mm Preparations Dear Customer, Thank you for choosing our product. For your safe concern, please take a few minutes

More information

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector DS970-BEL EN Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector DS970-BEL Installation Instructions.0 Installation Considerations.0 Installation Considerations Not suitable

More information

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm Operating & Maintenance Manual Alert-4 Ethernet LCD Master Alarm w w w. a m i c o. c o m Contents User Responsibility 4 Introduction 4 Features 5 Description of the Alarm 5 Shipment Details 5 The Alarm

More information

Installation Instructions EFS Hand Washing Station

Installation Instructions EFS Hand Washing Station Installation Instructions EFS Hand Washing Station Both water and soap are sequenced and dispensed from outlet. Override button allows for non potable, water-only dispensing. Lighted icons indicate the

More information

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER Instruction Manual Model AMB-12H PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USING THIS UNIT. Table of Contents 1. SAFETY WARNINGS 2 2. CONSTRUCTION...

More information

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01 OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01 Table of Contents Safety Instructions 4 Owner/Operator Responsibility 4 Specifications 5 Introduction 6 Installation Instructions 7 Setup 7 Wiring

More information

AM 213 Installation Introduction

AM 213 Installation Introduction EAGO Sanitary Ware Co.,Ltd. Factory Add:Shiling Development Zone,Xiaotang Town,Nanhai District,Foshan City,Guangdong,China E-mail:sales@eago.com.cn Http://www.eago.com.cn National Service Hotline:+86 800-8301359

More information

Bi-Directional Barrier Arm Turnstile

Bi-Directional Barrier Arm Turnstile ES831 *Custom model shown in stone and bronze Bi-Directional Barrier Arm Turnstile Model ES831 Optical Turnstiles > ES831 Series > Optical Turnstiles w/ Barrier Arms > Design Overview The ES831 bi-directional

More information

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE - SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN VC3ED ML-137013 - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly

More information

Dual Spin Mop Robot Cleaner

Dual Spin Mop Robot Cleaner Dual Spin Mop Robot Cleaner Copyright 2017 EVERYBOT Inc. All rights reserved. This publication is protected by copyright and all rights are reserved. No part of it may be reproduced or transmitted by any

More information

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum

More information

ARCHITECTURAL SPECIFICATIONS

ARCHITECTURAL SPECIFICATIONS 1 G4.1 Entrance System Page 1 of 6, August 2017 DIVISION 10 - SPECIALTIES SECTION 10450 PEDESTRIAN CONTROL DEVICES Specifier Note: Coordinate and edit articles and paragraphs below to suit project requirements.

More information

WALK-THROUGH METAL DETECTOR

WALK-THROUGH METAL DETECTOR WALK-THROUGH METAL DETECTOR OWNER S MANUAL MODEL TS-2000 SUNS International, LLC 1. Introduction The SUNS TS-2000 is a high-quality walkthrough metal detector that provides superior metal discrimination

More information

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Model Name Type 2 Models Owner s Guide and Installation Manual Model No. Catalog

More information

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed. Table of Contents Congratulations on purchasing your new Casablanca ceiling fan! It will provide comfort and performance in your home or office for many years. This installation and operation manual contains

More information

Laminator ZJY Series User Manual

Laminator ZJY Series User Manual Laminator ZJY Series User Manual Eastsign International Limited Room 1818, 18/F., Shatin Galleria, 18-24 Shan Mei Street, Fotan, Shatin, N.T., Hong Kong TEL: + 852-2117 0098 FAX: + 852-2117 0099 Website:

More information

21-light Remote Annunciator. Owner s Manual

21-light Remote Annunciator. Owner s Manual 21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With

More information

Massage Bathtub Instructions of Installation. MODEL:MT-RT1708 SIZE:1700*800*620mm

Massage Bathtub Instructions of Installation. MODEL:MT-RT1708 SIZE:1700*800*620mm Massage Bathtub Instructions of Installation MODEL:MT-RT1708 SIZE:1700*800*620mm Preparations Dear Customer, Thank you for choosing our product. For your safe concern, please take a few minutes to read

More information

MAGNETIC ELLIPTICAL TRAINER SF-E3416 USER MANUAL

MAGNETIC ELLIPTICAL TRAINER SF-E3416 USER MANUAL MAGNETIC ELLIPTICAL TRAINER SF-E3416 USER MANUAL IMPORTANT: Please read this manual carefully before using the product. Retain owner s manual for future reference. For Customer Service, please contact:

More information

Using the Remote Control Unit

Using the Remote Control Unit Remote Control Unit (continued) SENSOR button Temperature Display Selector button Time Display Selector button ACL button (ALL CLEAR) When you press this button (use a small-tipped object such as a ballpoint

More information

SlimStile BA. Tripod Turnstile for Internal Installation (*)

SlimStile BA. Tripod Turnstile for Internal Installation (*) Tripod Turnstile for Internal Installation (*) Tripod Turnstiles are compact and cost-effective entrance solutions designed for smooth and silent operation, less wear and tear and reduced power consumption,

More information

17.25 (438 mm) 37.5 (953 mm) 3.5 (89 mm) 3.0 (76 mm) 28 (711 mm) or 36 (915 mm)

17.25 (438 mm) 37.5 (953 mm) 3.5 (89 mm) 3.0 (76 mm) 28 (711 mm) or 36 (915 mm) ALVARADO Supervisor 2000-SM Optical Monitor Lane for Bi-directional Control Technical Specifications Dimensions Cabinet Length: Cabinet Height: Center Cabinet Width: End Cabinet Width: Clear Passage Width:

More information

INFORMATION ONLY READ AND SAVE THESE INSTRUCTIONS SAFETY FIRST

INFORMATION ONLY READ AND SAVE THESE INSTRUCTIONS SAFETY FIRST This information guide will help you with converting the electronics on the Comfort- Touch to Advan-Touch technology. Within this guide you will find step by step instruction on how to convert the fan,

More information

installation and operation manual for Hunter Ceiling Fans

installation and operation manual for Hunter Ceiling Fans For Your Records and Warranty Assistance Model Name: Catalog/Model No.: Serial No.: Date Purchased: Where Purchased: For reference also attach your receipt or a copy of your receipt to the manual. installation

More information

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX Page 1 of 10 Model 10807800 January 2014 ACCURATE ELECTRONICS INC PO BOX 1654 97075-1654 8687 SW HALL BLVD 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 WWW.ACCURATE.ORG Practice Section 10807800

More information

Speed Gate ST-01. Double-Sided Section STD-01 ASSEMBLY AND OPERATION MANUAL

Speed Gate ST-01. Double-Sided Section STD-01 ASSEMBLY AND OPERATION MANUAL Speed Gate ST-01 Double-Sided Section STD-01 ASSEMBLY AND OPERATION MANUAL Speed Gate ST-01 Double-Sided Section STD-01 Assembly and Operation Manual CONTENTS 1 APPLICATION...3 2 OPERATION CONDITIONS...4

More information

Please read this manual before using the machine. Please keep this manual within easy reach for quick reference.

Please read this manual before using the machine. Please keep this manual within easy reach for quick reference. INSTRUCTION MANUAL Please read this manual before using the machine. Please keep this manual within easy reach for quick reference. SINGLE NEEDLE DIRECT DRIVE STRAIGHT LOCK STITCHER WITH THREAD TRIMMER

More information

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE. TE-700I Installation and Operating Instructions Haverland TOWELS THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE. GENERAL RECOMMENDATIONS: * Please read these installation

More information

INSTALLATION INSTRUCTION for ceiling fan

INSTALLATION INSTRUCTION for ceiling fan INSTALLATION INSTRUCTION for ceiling fan F8203 Installation & Operating Instructions for the Parrotuncle Owner s Installation,Manual Motor is core parts of the fan and the most expensive in all the components.

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 1F83-51 Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL

More information

QUICK BGA2015 BGA/SMD Rework System. Operation Manual

QUICK BGA2015 BGA/SMD Rework System. Operation Manual QUICK BGA2015 BGA/SMD Rework System Operation Manual Thank you for purchasing our BGA/SMD Rework System. The system is exclusively designed for reworking and soldering SMD component. Please carefully read

More information

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60006PC SAFETY PRECAUTION. Canopy. Downrod. Housing. Blade. Transmitter CR2032/3V

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60006PC SAFETY PRECAUTION. Canopy. Downrod. Housing. Blade. Transmitter CR2032/3V L I G H T I N G INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:000PC SAFETY PRECAUTION PARTS & ACCESSORIES Canopy Downrod Housing IMPORTANT : PLEASE READ BEFORE INSTALLATION.. Do not connect this remote

More information

6 Inch Speed Dome Installation Manual V2.0.0

6 Inch Speed Dome Installation Manual V2.0.0 6 Inch Speed Dome Installation Manual V2.0.0 2010-01 1 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to

More information

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series Installation CRS-2/IR, CRS-3/IR Express Crescent Lavatory System CRS-Series CRS-3/IR/LSD Complies with Texas Accessibility Standards (TAS) for Juvenile Height applications. Table of Contents Dimensions...2

More information

SERVICE MANUAL MULTI DECK 60 HOT MERCHANDISER MULTI DECK 100 HOT MERCHANDISER MULTI DECK 120 HOT MERCHANDISER CLASSIC DECK HOT MERCHANDISER

SERVICE MANUAL MULTI DECK 60 HOT MERCHANDISER MULTI DECK 100 HOT MERCHANDISER MULTI DECK 120 HOT MERCHANDISER CLASSIC DECK HOT MERCHANDISER SERVICE MANUAL MULTI DECK 60 HOT MERCHANDISER MULTI DECK 100 HOT MERCHANDISER MULTI DECK 120 HOT MERCHANDISER CLASSIC DECK HOT MERCHANDISER Classic Deck Hot Multi Deck 60 Multi Deck 100 Multi Deck 120

More information

HDCVI PIR Camera User s Manual

HDCVI PIR Camera User s Manual HDCVI PIR Camera User s Manual Version 1.0.1 Table of Contents 1 General Introduction... 1 1.1 Overview... 1 1.2 Features... 1 2 Device Framework... 2 3 Detection Range... 4 4 Device Installation... 5

More information

Installation Guide BUILT-IN SXS REFRIGERATOR UPSXB2627**

Installation Guide BUILT-IN SXS REFRIGERATOR UPSXB2627** Installation Guide BUILT-IN SXS REFRIGERATOR UPSXB2627** www.thesignaturekitchen.com 2 Contents 1. Precaution before installation... 3 2. Product and Cutout dimension... 4 3. Precaution when moving the

More information

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual ABLOY DA460 SWING DOOR OPERATOR Installation and commissioning manual APPROVALS / STANDARDS 73/23/EEC (Low Voltage directive) 93/68/EEC (Low Voltage directive) 89/336/EEC (EMC directive) Statement of fire

More information

Instruction manual. Remote control electric IR HEATER

Instruction manual. Remote control electric IR HEATER Instruction manual Remote control electric IR HEATER battery consumption rate hour temperature (preset or measured) current operation mode (e.g. comfort) current day heating activated buttons for adjustment

More information

Dahua HD Mini IR Waterproof Bullet Network Camera. Quick Start Guide

Dahua HD Mini IR Waterproof Bullet Network Camera. Quick Start Guide Dahua HD Mini IR Waterproof Bullet Network Camera Quick Start Guide Version 1.0.0 Zhejiang Dahua Vision Technology Co., LTD Welcome Thank you for purchasing our Network camera! This user s manual is designed

More information

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL IMPORTANT WARNING WHEN THE CO MONITOR IS CORRECTLY INSTALLED AND MAINTAINED, IT MONITORS THE LEVEL OF CARBON MONOXIDE IN ITS SURROUNDINGS..

More information

Four-Door Access Controller User s Manual

Four-Door Access Controller User s Manual Four-Door Access Controller User s Manual V1.0.0 1 Table of Contents 1 Overview... 1 2 Device Appearance... 2 3 Device Installation and Uninstallation... 3 3.1 Device Installation... 3 3.2 Device Uninstallation...

More information

Revision B Printed Fall Elston Manufacturing HC Heater Owners Manual

Revision B Printed Fall Elston Manufacturing HC Heater Owners Manual Revision B Printed Fall 2007 Elston Manufacturing HC Heater Owners Manual Table of Contents Important Safety Information... ii 1) Description of Heater... 1 General information about your heater including

More information

Custom options such as housing finishes and design, lid have their presence felt. A combination of sleek, sophisticated

Custom options such as housing finishes and design, lid have their presence felt. A combination of sleek, sophisticated OptiStile 720FH Gone are the days where clunky, large pedestals are required to Custom options such as housing finishes and design, lid have their presence felt. A combination of sleek, sophisticated and

More information

966A AIR IONIZER. SUMITOMO 3M LIMITED Electronic Solutions Division

966A AIR IONIZER. SUMITOMO 3M LIMITED Electronic Solutions Division 966A AIR IONIZER Operation Manual Precautions...1 Safety precautions...1 Other precautions...1 Outline...2 Structure and kinds of the ionizer...2 Specifications...2 Characteristic...3 How to Install 966A

More information

Pre-Installation Instructions. Installation Instruction. Installation Instructions. kah. wall. Warning. User s Manual and warranty

Pre-Installation Instructions. Installation Instruction. Installation Instructions. kah. wall. Warning. User s Manual and warranty Pre-Installation Instructions Installation Instruction User s Manual and warranty Installation plate Junction valve Check if the accessories fit your toilet dimension and then install bidet seat. Remote

More information

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone! Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone! GSM SMS Controller DCS-130 User Manual Ver 1.20 Date Issued: 14-9-2010

More information

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document. EN LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS Visit website for available languages of this document. 75.5947.03 LZR-FLATSCAN SW 20190206 Page 1 of 16 DESCRIPTION 1 2

More information

F A B G L A S S A N D M I R R O R

F A B G L A S S A N D M I R R O R Frameless Panel MSD1 FAB GLASS AND MIRROR www.fabglassandmirror.com Call: +1 888-474-2221 Office Timing: 8:30-18:00 EST Fax: (614)-334-4919 info@fabglassandmirror.com INSTALLATION INSTRUCTION SHOWER ENCLOSURE

More information

SHORT WAVE INFRARED PANEL DRYER

SHORT WAVE INFRARED PANEL DRYER INSTRUCTIONS FOR: SHORT WAVE INFRARED PANEL DRYER MODEL: IR3000 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and

More information

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72 Owner s Guide and Installation Manual 3MNLR72XXD Series Fan UL Model NO. : 3MNLR72 Attach sales receipt to this card and retain as your proof of purchase DATE OF PURCHASE: MODEL NUMBER: RETAILER NAME:

More information

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08 Beacon 200 Gas Monitor Operator s Manual Part Number: 71-2102RK Released: 6/6/08 Table of Contents Chapter 1: Introduction.................................................3 Overview.............................................................3

More information

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual RC802/804-240B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual Raisecom Technology Co., Ltd. (04/2005) 1. Cautions Please read the following notices carefully before installing and using the device,

More information

JASOPELS ROTATING FLESHING MACHINE 1-BEAM

JASOPELS ROTATING FLESHING MACHINE 1-BEAM USER MANUAL JASOPELS ROTATING FLESHING MACHINE 1-BEAM ITEM NO. 32200067 Our quality Your choice 2 www.jasopels.com TABLE OF CONTENTS About this document... 3 Declaration of Conformity... 6 Safety... 6

More information

Installation Manual. Read the user manual carefully before using this product

Installation Manual. Read the user manual carefully before using this product IR High Speed Dome Camera Installation Manual Read the user manual carefully before using this product Table of Content 1 Waterproof... 3 2 Anti static, anti interference, anti thunder, anti surge...5

More information

Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual

Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual Version 1.5 1 CONTENTS CHAPTER 1 GENERAL INTRODUCTION...3 1. Preface... 3 2. Product Introduction... 3

More information

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS EN LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS 75.5947.01 LZR-FLATSCAN SW 20180627 Page 1 of 16 DESCRIPTION 1 2 3 4 5 6 7 8 11 12 13 14 15 16 9 10 17 18 1. cover 2. push

More information

PROFESSIONAL S2 SAFE USER GUIDE ELECTRONIC LOCK USER GUIDE.

PROFESSIONAL S2 SAFE USER GUIDE ELECTRONIC LOCK USER GUIDE. USER GUIDE PROFESSIONAL S2 SAFE ELECTRONIC LOCK USER GUIDE www.chubbsafes.com Chubb is owned by Chubb plc and is a registered trademark used under license General Description The lock is operated by a

More information

Pioneer-R16 Gas Monitor Operator s Manual

Pioneer-R16 Gas Monitor Operator s Manual Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas

More information

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265 Mobile Air Conditioner Use and Care Manual Part Number: 048-GM-48265 Thank you very much for selecting this new model of Portable Air Conditioner, please read this Use and Care Manual carefully before

More information

The following modes can be set when the units are installed, and/or can be changed later through use of a push button on the desktop controller:

The following modes can be set when the units are installed, and/or can be changed later through use of a push button on the desktop controller: OptiStile 720 OptiStile 720 Optical Barrier-type flow control turnstile for Internal Installation with swinging glass doors Technical Specification Orientation: Bi-Directional Unit Dimensions: Casework

More information

HX-80NRAM. High Mount Outdoor Detector

HX-80NRAM. High Mount Outdoor Detector Battery operated with 2 PIRs and HX-80NRAM anti-masking Battery operated Battery saving logic Compatible with most wireless transmitter Long distance detection area (24.0 m) Flexible detection area setting

More information

Product Data Sheet. Remote Terminals. Features:

Product Data Sheet. Remote Terminals. Features: Remote Terminals Product Data Sheet Features: Based around two core products, the Mx- 4010 Remote Display Terminal (RDT) and the fully functional Mx-4020 Remote Control Terminal (RCT). Both remote terminals

More information

FSLIMPRO

FSLIMPRO 1. INTRODUCTI FSLIMPRO is especially designed and built for quick and easy installation. Installation is truly made easy and wiring up is minimised (only the power supply cable and alarm contacts require

More information

Wired Controller XK60

Wired Controller XK60 Owner's Manual Commercial Air Conditioners Thank you for choosing Commercial Air Conditioners, please read this owner s manual carefully before operation and retain it for future reference. User Notice

More information

IR Intelligent Speed Dome Installation Manual

IR Intelligent Speed Dome Installation Manual IR Intelligent Speed Dome Installation Manual Version 1.0.0 Table of Contents 1 INSTALLATION PREPARATION... 1 1.1 Basic Requirement... 1 1.2 Installation Check... 1 1.3 Cable Preparation... 1 1.3.1 The

More information

RMS/RPX Reader. User Manual

RMS/RPX Reader. User Manual RMS/RPX Reader User Manual Copyright Disclaimer Trademarks and patents Intended use FCC compliance Copyright 2005, GE Security Inc. All rights reserved. This document may not be copied or otherwise reproduced,

More information

QD6310. Fixed Gas Detector Operation Manual

QD6310. Fixed Gas Detector Operation Manual QD6310 Fixed Gas Detector Operation Manual Safety Information Before using the device, please first carefully read and follow the following information to operate the device: Please don't use the defective

More information

USER MANUAL. FairWind FWPC6L Pressure Cooker. Contact Us:

USER MANUAL. FairWind FWPC6L Pressure Cooker. Contact Us: USER MANUAL FairWind FWPC6L Pressure Cooker Contact Us: 1-844-528-2566 Read and Save These Instructions TABLE OF CONTENTS SPECIFICATIONS... 2 Parts List... 3 Important Safety Instructions... 4 Installation

More information

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V L I G H T I N G INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:000BZGTGLD SAFETY PRECAUTION PARTS & ACCESSORIES Canopy Downrod Housing WARNING To make sure power is off before attempting installation. WARNING

More information

MST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL

MST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL MST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL IMPORTANT WARNING WHEN THE OXYGEN MONITOR IS CORRECTLY INSTALLED AND MAINTAINED, IT MONITORS THE LEVEL OF OXYGEN IN ITS SURROUNDINGS 07/11

More information

OptiStile 220. Swinging Barrier Arm Optical Turnstile

OptiStile 220. Swinging Barrier Arm Optical Turnstile The OptiStile 220 has been a staple within Gunnebo s product line since its inception. With proven results and reliability, the OptiStile 220 series of optical turnstiles with barrier arms is a welcomed

More information

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE D (OPERATION) INITIATE A DYNAMIC BATTERY TEST The system tests the back-up battery once every 24 hours. The owner can initiate a dynamic battery test at any time with the following codes while the system

More information

Portable Air-conditioner

Portable Air-conditioner Use and Care Manual Portable Air-conditioner Thank you very much for selecting this new model of Portable Air Conditioner, please read this Use and Care Manual carefully before installing and using this

More information

QUICK BGA2005. Operation Manual

QUICK BGA2005. Operation Manual QUICK BGA2005 BGA/SMD Rework System Operation Manual Thank you for purchasing our BGA/SMD Rework System. The system is exclusively designed for reworking and soldering SMD component. Please carefully read

More information

Fillmore Small Pendant Assembly and Installation Instructions

Fillmore Small Pendant Assembly and Installation Instructions CAUTION: Fillmore Small Pendant Assembly and Installation Instructions BEFORE INSTALLING FIXTURE, MAKE SURE THE POWER TO THE CIRCUIT IS TURNED OFF AT THE MAIN FUSE BOX / CIRCUIT BREAKER UTILITY BOX. Important

More information