Operation Manual. Hatsuta Seisakusho Co., Ltd.

Size: px
Start display at page:

Download "Operation Manual. Hatsuta Seisakusho Co., Ltd."

Transcription

1 Operation Manual Thank you very much for the choice of our Argonite Amulay 30. The Argonite Amulay 30 automatically conducts all the processes ranging from fire detection to extinguishing agent discharge to cope with a fire in the protected area, thereby extinguishing it. You can also discharge the extinguishing agent manually. It will surely be useful in the case of an unexpected fire. We therefore recommend you to read this operation manual carefully and use the product correctly. Hatsuta Seisakusho Co., Ltd. June 2007

2 Contents Chapter 1 Important information Important information on operation 2. Important information on maintenance and inspection Chapter 2 Overview Overview description 2. Diagram of standard examples of installation 3. Diagram of the unit and its components and their names Chapter 3 What the control unit does and how to handle it... 7 Chapter 4 Operation description For automatic fire extinguishing 2. For manual fire extinguishing 3. Automatic flowchart 4. Manual flowchart Chapter 5 How to make terminal connections Connection to the terminal block of the control panel 2. How to turn on the power supply Chapter 6 Post-activation treatment Chapter 7 Maintenance and inspection Daily inspection 2. Periodic inspection

3 Before installation, operation, maintenance, or inspection, be sure to read this operation manual and its attachments carefully. Then use the product correctly. Please become familiar with all the knowledge of the equipment, safety information, and the precautions before using the equipment. This manual ranks the safety precautions as "danger," "warning," and "caution."! Danger Cases when mishandling is expected to cause a risky situation resulting in death or major injury and which are limited with a high degree of warning urgency (degree of imminence) in the case of a danger generated (that is, limited to high-degree risks).! Warning Cases when mishandling is expected to cause a risky situation resulting in death or major injury.! Caution Cases when mishandling is expected to cause a risky situation resulting only in minor injury or property damage. Please be sure to observe the precautions specified in! Caution as well because they may lead to a serious result depending on the situation. They are all important. Chapter 1 Important information 1. Important information on operation! Danger Do not touch the equipment with a wet hand. It may give you an electrical shock. Do not touch the equipment when a violent lightning is occurring either.! Danger When the equipment is activated, evacuate the protected area (go out of the protected room) promptly. Staying in the protected room is risky.! Warning Do not do the following, which may result in a fire, electric shock, breakdown, earth leakage, or other incident. Do not disassemble or remodel the equipment. Do not put a high-temperature object or humidifier near the equipment. Do not give a strong impact or shock to the equipment.! Warning When you want to move the equipment be sure to commission the work to your dealer, service company, maintenance company, or manufacturer having a licensed fire-extinguishing equipment operator. Operation by an unlicensed person or any person without the necessary knowledge of the equipment may result in the extinguishing agent being discharged inadvertently or in the equipment being damaged, which is very dangerous.! Warning If you find a fire and start the equipment manually, check that there are no persons in the protected section before pressing the start button. After pushing the start button, go out of the protected section speedily. Staying in the protected room is risky.! Caution Keep both the primary power and the secondary power "ON " at all times. The equipment will not function unless energized.! Caution Be sure to keep the maintenance switch in the "Normally" position. The extinguishing agent will not discharge, even in the case of a fire, if the equipment is set to the "Maintenance" position. 1

4 2. Important information on maintenance and inspection! Warning Do not let water or other foreign matter enter into the equipment, which may result in an electric shock or breakdown.! Warning Do not place any of the following by the equipment: vase, flower pot, glass or cup, cosmetics, drug container, or small metal fitting. If any such thing enters, an electric shock or breakdown may result.! Warning If you want to inspect or repair the equipment in the protected section, or if you want to engage in any other equipment works, be sure to put the maintenance switch to the "Maintenance" position before beginning work. If you work with the switch set to the "Normally" position, you may activate the equipment inadvertently, which is very dangerous.! Warning After discharging the extinguishing agent and before entering the protected area, be sure to ventilate the room with the ventilator installed there. Entering the room without sufficient ventilation might be dangerous.! Caution Be sure to perform daily inspection before each shift and periodic inspection once every six months. Perform daily inspection and periodic inspection according to "Chapter 7 Maintenance and inspection" of this operation manual. If the electrical wiring is damaged (such as an exposed core or a wire break)... If water or foreign matter enters the equipment... If the equipment drops or falls... If a daily inspection reveals an abnormality... Shut down the power supply promptly and be sure to commission servicing or repair of the equipment to your dealer, service company, maintenance company, or manufacturer having a licensed fire-extinguishing equipment operator. 2

5 Chapter 2 Overview 1. Overview description What is Argonite Amulay 30? An automatic fire-extinguishing system capable of detecting a fire, discharging extinguishing agent, and extinguishing the fire automatically. Can be manually discharged if a person discovered a fire before the equipment did. Argonite extinguishing agent is a clean, environmentally friendly extinguishing agent consisting only of argon and nitrogen and with a zero ozone layer depletion coefficient and a zero global warming coefficient. Basic knowledge of Argonite Amulay 30 An integral type with its control functions and extinguishing agent contained in a compact unit box. The power supply used is based on a dedicated primary power supply of 100 V AC (which can optionally be changed to 200 V). The secondary power supply is 24 V DC. The fire sensor system is nationally certified. (It basically consists of two kinds of sensors: heat sensor and smoke sensor.) The control circuit is equipped with a "self-diagnosis function." It emits a fault alarm (intermittent beeping and error lamp blinking) in the case of any of the following errors: Manual Release line fault Sensor line open circuit Ground fault Circuit voltage fauly Actuator line fault Actuator connection fault A maintenance switch is installed to prevent accidents during inspection, thereby avoiding the inadvertent discharge of extinguishing agent during maintenance. Turning the maintenance switch to the "Maintenance" position will cause the maintenance lamp to flash, and shut down the signal circuit to the gas cartridge actuator that opens the valve. The availability of various interface functions enables you to take out signals for stopping and activating related equipment (such as fans, air-conditioners, pumps, and motors) in an interlocked manner, along with fire alarm signals and other signals. If the object to be protected is too large to be covered with the given extinguishing agent capacity, sub-type equipped with a built-in extinguishing agent container can be added. 3

6 2. Diagram of standard examples of installation System diagram for fire-extinguishing equipment 放出表示灯 Discharge indicator メインタイプ Main type 噴射ヘッド Nozzle Alarm speaker 警報スピーカー (built-in) ( 内蔵 ) Smoke 煙感知器 sensor Heat 熱感知器 sensor Pressure 避圧口 relief outlet 換気装置 Ventilator S Manual 手動起動装置 Release サブ用 Storage container 貯蔵容器 startup 起動配線 wiring for sub-type (electrical interlocking signals) サブタイプ Sub-type Interlocking system diagram Electrical 電気連動信号 interlocking ( 耐熱ケ signal -ブル (heat-resistant ) cable) メインタイプ Main type サブタイプ Sub-type サブタイプ Sub-type サブタイプ Sub-type * The equipment is suited for protected sections of up to 1,500 m 3, depending on the object to be protected from fire. * The equipment can be connected to up to 11 sub-types for each main type regardless of the number of containers. 4

7 3. Diagram of the unit and its components and their names Main type for two cylinders 2050 噴射ヘッド Nozzle 警報 Alarm スピーカー speaker Front フロント panel パネル Startup 起動扉 door 重要情報 Important シール information sticker Gascartridge ガス発生式 actuator 弁開放器 Pilot 起動用 Cylinder ガス用器 フレキシブル Flexible tube チューブ Pressure 減圧弁 reducing valve 圧力スイッチ Pressure switch 容器弁 Container valve 弁開放器 Actuator Extinguishing 消火剤容器 agent container Acoustic 音声警報 alarm unit ユニットメンテナンス Maintenance スイッチ switch 地絡検出器 Ground fault 地絡継 sensor 電器 制御盤 Control panel 非常用 Power supply 電源 バッテリー Battery Cabinet 格納箱 Inside 格納箱内部 the cabinet Rear side 扉部裏面 of the door Main type for three cylinders 2050 噴射ヘッド Nozzle 警報 Alarm speaker スピーカー Front フロント panel パネル Startup 起動扉 door Important information 重要情報 sticker シール Gas- ガス発生式 cartridge 弁開放器 actuator 起動用 Pilot ガス用器 cylinder フレキシブル Flexible tube チューブ Pressure 減圧弁 reducing valve 圧力スイッチ Pressure switch 容器弁 Container valve 弁開放器 Actuator Extinguishing agent 消火剤容器 container Cabinet 格納箱 Inside 格納箱内部 the cabinet * The door of the main type for three pieces (the rear side of the door) is common with the door of the main type for two pieces. 5

8 Sub-type for two cylinders Nozzle 噴射ヘッド Gas- ガス発生式 cartridge actuator 弁開放器 Pilot 起動用 cylinder ガス用器 フレキシブル Flexible tube チューブ Pressure 減圧弁 reducing valve Container 容器弁 valve 弁開放器 Actuator 2050 Extinguishing 消火剤容器 agent container Inside 格納箱内部 the cabinet Sub-type for three cylinders Nozzle 噴射ヘッド ガス発生式 Gas-cartridge 弁開放器 actuator 起動用 Pilot cyinder ガス用器 フレキシブル Flexible tube チューブ減圧弁 Pressure reducing valve 容器弁 Container valve 弁開放器 Actuator 2050 消火剤容器 Extinguishing agent container Inside 格納箱内部 the cabinet 6

9 Chapter 3 What the control unit does and how to handle it There is a front panel for control display on the front face of the unit door of the main type. (It is not available on the sub-types.) It displays the set status of the Amulay. It also displays the fire status and emits an alarm in the case of an emergency. AMULAY FIRE パッケージ型消火システム EXTINGUISHING SYSTEM 火 Fire 災 ZONE 1 ALARM No.1 感知ライン作動 ZONE 2 ALARM No.2 感知ライン作動 システムのセ SYSTEM MODE ット状況 AUTOMATIC 自動システムが 自動 にセットされていることを Extinguishing gas is discharged Automatically or Manually 示します MANUAL 手動 Extinguishing システムが 手動 にセットさ gas is discharged れていることを only Manually 示します モニター FAULT Manual Coufirvation Of fire 火災確認 手動 Manual 自動 Automatic 起 ACTUATE 動タイマー COUNT DOWN TIMER ( 秒 ) 消火剤放出までの時間を表す Zone No.1 1 Fault 感知ライン異常 Zone No.2 2 Fault 感知ライン異常 Ground 地絡 Fault Circuit 回路電圧 Voltage 異常 Fault Manual 手動起動 Release 装置ライン異常 Line Fault Actuator 弁開放器 Line ライン異常 Fault Actuator 弁開放器 Connection セット不良 Fault Maintenance メンテナンス NORMAL 常時 システムが使用可 : System is Normal Mode 能です MAINTENANCE: 点検 システムが点検状 System is Set 態です for Maintenance DISCHARGE 放出 切替キースイッチ AUTO / MANUAL SWITCH Manual Automatic 主手動主自動 非常停止押釦 ABORT MANUAL 放出押釦 RELEASE 7

10 Display Fire indicator: Goes on when the sensor detects a fire or the door to the manual release is opened. Zone 1 Alarm indicator: Goes on when the sensor line No. 1 detects a fire. Zone 2 Alarm indicator: Goes on when the sensor line No. 2 detects a fire. Manual indicator: Goes on when the system is set to manual. Automatic indicator: Goes on when the system is set to Automatic. Actuate indicator: When the start button is pressed, or when set to Automatic: When set to OR: one of the Zones activates. When set to AND: both of the Zones activate. It flashes, and then stays ON after the countdown time is finished. Count down timer: Counts down the time from system actuate to extinguishing agent discharge. (Setting the delay time to 10 seconds will cause it to count down from "10" to "0.") Discharge indicator: Flashes at extinguishing agent discharge. Fault Zone 1 Fault / Zone 2 Fault indicators: Flashes when there is an open circuit fault in sensor line 1 or 2. Circuit Voltage Fault indicator: Flashes when the control voltage is below 20.7 V DC or above 32 V DC. Manual Release Line Fault indicator : Flashes when there is a fault in the manual release line. Actuator Line Fault indicator: Flashes when the is a fault in the actuator line. Ground Fault indicator: Flashes when there is a ground fault in the power supply line or the manual release line. Actuator Connection Fault indicator: Flashes when the actuator is disconnected. Maintenance Normal indicator: The normal state is ON (If this is OFF, extinguishing agent will not discharge, even if there is a fire.) Maintenance indicator: Flashes when the maintenance switch is set to Maintenance (When in Maintenance mode, the actuator line is disabled so extinguishing gas will not discharge.) Auto/manual selector The system can be selected to discharge only manually, or automatically and manually "Manual" position: Extinguishing agent can only be discharged by pushing the Manual Release. "Automatic" position: Extinguishing can be discharged by pushing the Manual Release, or by activation of a detector (Detectors in Both Zones when AND mode is selected, Any detector in Any Zone when OR mode is selected) The equipment can be switched between Auto and Manual by operating the Auto/Manual switch of the Manual Release (optional) regardless of the position of this selector. Check the set status of the system by checking whether the indicator of the Auto or Manual indicator on the front panel is on. Set the switch to "Manual" when personnel enter the protected area. At nighttime, when no one is present, set the switch to "Automatic." 8

11 Abort Switch Press this button to stop a discharge after the discharge countdown has started. (It is effective while the countdown is displayed on the digital timer. Once the discharge starts, it cannot be stopped.) After the system has activated and the extinguishing agent has discharged, pressing this switch will electrically reset the system. If the system does not reset, some parts may need to be reset manually. It is also used to restore the system when there is a Fault alarm. However, it will not restore the equipment while the Fault remains. Manual Release (inside the startup door) Press this to discharge the extinguishing agent manually. (This operation has priority over all other functions other than the Abort button.) Maintenance switch (on the rear side of the door) Putting the switch to the "Normal" position will put the equipment in normal mode. Putting it to the "Maintenance" position will put it in maintenance mode. Maintenance mode is used to prevent inadvertent discharge of extinguishing agent during maintenance. As soon as maintenance is complete, therefore, set the equipment to the "Normal" position. The front panel has indicators to show the state of the system. Top view of the rear side of the door Maintenance switch Chapter 4 Operation description 1. For automatic fire extinguishing (a choice of the AND circuit system or the OR circuit system) For the AND circuit system (standard system) In response to a fire signal from the sensor connected to either of the two fire sensor lines, the speaker will broadcast fire-extinguishing instructions, which instruct the persons indoors to identify and extinguish the fire. In response to a fire signal from the sensor connected to the other fire sensor line, or in response to a startup operation, the speaker will broadcast evacuation instructions, which recommend the persons indoors to evacuate the place. At the same time, the front panel counts down (digitally displays) the time remaining to discharge of the extinguishing agent. When the preset delay time is up, extinguishing agent will be discharged. The standard delay time is 10 seconds. (The equipment can be set to any value between 5 and 10 seconds.) For the OR circuit system In response to a fire signal from either of the two fire sensor lines, the speaker will broadcast evacuation instructions, which recommend the persons indoors to evacuate the place. At the same time, the front panel counts down (digitally displays) the time remaining to discharge of extinguishing agent. When the preset delay time is up, extinguishing agent will be discharged. The standard delay time is 10 seconds. (The equipment can be set to any value between 5 and 10 seconds.) Manual release has priority over everything else. 9

12 2. For manual fire extinguishing (when set to Manual) In response to a signal from a fire sensor line, the system will emit a fire alarm but will not discharge. Startup is conducted by a startup operation. In response to a fire signal from either of the two fire sensor lines, the speaker will broadcast fire-extinguishing instructions, which instruct the persons indoors to identify and extinguish the fire. A startup operation causes the speaker to broadcast evacuation instructions, recommending the persons indoors to evacuate the place. At the same time, the front panel counts down (digitally displays) the time remaining to discharge of extinguishing agent. When the preset delay time is up, extinguishing agent will be discharged. For emergency stoppage For both automatic fire extinguishing and manual fire extinguishing, and if the fire is controlled or extinguished before the digital timer reads "0," the "Abort button" on the front panel can be pressed to make an emergency stop of the system, thereby stopping discharge of the extinguishing agent. 10

13 3. Automatic flowchart Inspection in progress Monitoring in progress Maintenance switch Normally "Inspection lamp" blinks "Normal lamp" on Extinguishing agent discharge Fire occurred Discovered by a person Sensor line No. 1 activated Sensor line No. 2 activated "Sensor line No. 1 activation lamp" on "Sensor line No. 2 activation lamp" on Open the startup door "Fire lamp" on Fire notice (1a) When set to OR When set to AND Sensor line No. 1 Sensor line No. 2 Either of the two activated Sensor line No. 1 Sensor line No. 2 Both activated Sensor line No. 1 Sensor line No. 2 Either of the two activated Press the discharge button Evacuation instructions Fire extinguishing instruction broadcast Note: When the system is to be set to OR, it may consist of a single sensor line. Digital timer activated Digital timer countdown Abort switch pressed? Digital timer display "0" "Start lamp" blinks. Start (machine stoppage) Notice (3c, 1a) Both sensor lines activated Fire extinguishing broadcast suspended Note: The machine stoppage notice contacts include air-conditioner stoppage. Extinguishing agent discharged System restored Fire extinguished "Discharge lamp" on Discharge notice (1a) Extinguishing agent full indicator blinks 11

14 4. Manual flowchart Monitoring in progress Maintenance switch Inspection in progress Normally "Inspection lamp" blinks "Normal lamp" on Extinguishing agent discharge Fire occurred Sensor line No. 1 activated Sensor line No. 2 activated "Sensor line No. 1 activation lamp" on "Sensor line No. 2 activation lamp" on Discovered by a person "Fire lamp" on Fire notice (1a) Fire extinguishing instruction broadcast Fire confirmed Open the startup door Evacuation instructions Press the discharge button Digital timer activated Digital timer countdown "Start lamp" blinks. Start (machine stoppage) Notice (3c, 1a) Emergency stop switch pressed? Digital timer display "0" Note: The machine stoppage notice contacts include air-conditioner stoppage. Extinguishing agent discharged System restored Fire extinguished "Discharge lamp" on Discharge notice (1a) Extinguishing agent full indicator blinks 12

15 Chapter 5 How to make terminal connections 1. Connection to the terminal block of the control panel Terminator Smoke/heat sensor Sensor Fire-extinguisher manual release (standard) (connected to the same terminal code) Door switch Start button Emergency stop button Selector Manual indicator Auto indicator Start indicator Inspection indicator Power supply (24 V) Power indicator Actuator Door switch Start button Emergency stop button Selector Manual indicator Auto indicator Fire indicator Start indicator Error indicator Inspection indicator Reset Power supply (24 V) Speaker Power supply (0 V) Main control unit Sub-discharger Ground fault sensor Maintenance switch Pressure switch External takeout power supply (up to 0.7 A) Extinguishing agent full indicator Actuator *1 Auto/manual setting notice *2 Fire notice *3 Extinguishing agent discharge notice *4 Error notice *5 Start notice *1 *2 *3 *4 *5 Interlock notice for machine stoppage, etc. Interlock terminal Input power supply 24 V DC 13

16 2. How to turn on the power supply To turn on the power of the Amulay, follow the procedures described below. A mistaken procedure may result in breakdown. Turn off the power switch of the control panel and the power switch of the power supply. Check if the wiring and connectors of the control panel and power supply are correctly connected. Connect the connectors between the power supply and battery. Caution: Unless the battery connectors are connected, the fire extinguisher will not become activated in the case of a blackout. Turn on the power switch of the power supply. For power supplies, the AC power lamp (green) and power circuit lamp (green) will go on. (For models equipped with charge indicator, this indicator (green) will go on as well.) For certified power supplies, the power indicator (red) will go on, with the voltmeter reading 24 V DC. Turn on the power switch of the control panel. Caution: To shut down the power supply or exchange batteries for inspection or other purposes, proceed with the work in reverse of that procedure. Caution: If the primary power supply is to be shut down for more than an hour, the battery may be excessively charged, resulting in deterioration. Therefore turn off the power switch of the control panel and the power switch of the power supply and disconnect the battery connectors. For restoration, follow the procedure described above. (Do not forget to connect the battery connectors.) Note that the equipment is not active (in a monitoring state) when its primary power is shut down and the battery is disconnected. When connected to a new or discharged battery, the equipment takes about 48 hours until its charging is complete. Note: The battery lasts about five years. It should be replaced after 5 years. Chapter 6 Post-activation treatment If the Argonite Amulay 30 is activated and has discharged its extinguishing agent, be sure to have it repaired promptly by your dealer, service company, maintenance company, or manufacturer having a licensed fire-extinguishing equipment operator. After it is activated, be sure to replace the following parts: Pilot cylinder Extinguishing agent container (rechargeable) Gas-cartridge actuator Fire-damaged parts (including detectors and wiring) 14

17 Chapter 7 Maintenance and inspection 1. Daily inspection The Argonite Amulay 30 is only used in the case of fires. Be sure to perform daily inspection before the shift every day to ensure that the equipment functions normally and displays its effect fully in the case of an unexpected fire. The normal indicator on the front panel is on. Normal Either the auto indicator or the manual indicator on the front panel is on. Normal The indicators on the front panel other than those mentioned above are off. Normal The beeper is not sounding. Normal The door to the unit cabinet is properly closed. Normal The unit cabinet and external connection equipment are free of damage. The connections are free of abnormalities. Normal 2. Periodic inspection (Fill out the maintenance and inspection record card.) The Argonite Amulay 30 must be inspected as described below by a legally authorized licensed person (a licensed fire-extinguishing equipment operator A-3 or B-3 or a licensed fire-extinguishing equipment inspector) or someone similar according to legally established standards. Equipment inspection: Once every 6 months (twice a year) Comprehensive inspection: Once every 12 months (once a year) (Comprehensive inspection includes equipment inspection. Every year, therefore, one equipment inspection and one comprehensive inspection must be conducted, two in total.) Gas-cartridge actuator and batteries have a service life of about five years. Five years later, replace them. 15

18 Package-type automatic fire-extinguishing equipment Argonite Amulay 30 Specifications *Equipment specifications (main type) Equipment name Argonite Amulay 30 Evaluation number Product name Model code Total equipment w eight (w hen in an 83 L container) Extinguishing agent type Extinguishing agent cylinder (internal volume) Extinguishing agent volume (20 C) Extinguishing agent cylinder Cabinet dimensions Cabinet structure Cabinet paint Operating temperature range Operating humidity range Acoustic alarm device Manual starter *Electrical specifications Startup system Sensor circuit Acoustic alarm device Delay circuit Fault Monitoring function Relay Contact functions 1) Manual/auto Contact c 1 Relay Contact specifications Gas Cartridge Actuator Pilot Cylinder Maintenance functions (switchover with a maintenance switch) Main type with 1 cylinder AGNM1-8322/6818 Main type with 2 cylinders AGNM2-8322/6818 IG L (extinguishant container for model 8322), 68 L (extinguishant container for model 6818) 21.8 m 3 ( for an internal volume of 83 L), 17.8 m 3 (for an internal volume of 68 L) Contact a 1 Contact a 1 Contact a 1 Contact a 1 Contact c 3 Main type with 3 cylinders Approx. 180 kg Approx. 410 kg Approx. 575 kg Material: CrMo steel, etc., pressure for pressure testing: 50 MPa, paint color: gray W400 D400 H2050 Front-panel single-swing type (t = 1.6 mm) W950 D400 H2050 Paint color: White (similar to Japan Paint Manufacturers Association TN-85 "1995") The main type is of the manual/auto selector type. 1) Sensor Line Fault 2) Ground Fault 3) Circuit Voltage Fault 5) Actuator Line Fault 2) Fire 4) Discharge Gas evaluation No. 441 W650 D400 H C to +40 C AA-008 (certified product) AGNM3-8322/6818 The sub-type is interlocked w ith the main type. 2-channel sound synthesis, acknowledgment number: AA-008 6) Actuator Connection Fault : The indicator flashes, the beeper sounds. 5) Fault 6) Machine stop contact A choice of 2 lines (AND and OR operations) Can be set to a desired value between 5 and 10 seconds. 4) Manual Release Line Fault 3) Actuaton 85% or less, non-condensing Model code; RPB-337 (including Gas evaluation No. 441) Contact capacity: 60 W, 125 VA max. Max. current: 1 A, max. voltage: 250 V AC, 220 V DC Model code: GHK-6A Normally: Normal indicator on,... the system is available. Indicator flashes, beeper sounds, and fault alarm is produced. Model code: N2-B11.2, charge pressure (17.65 MPa), charge gas weight (11.2 g) Maintenance: Maintenance indicator flashes,... The actuator output signal is disabled. Circuit voltage Power consumption Power supply 24 V DC 50 W max. Either of the types listed below can be selected and installed inside the equipment. Power supply (charger and battery) 1) Battery capacity: 3.5 AH, Input; 100 V AC 2) Battery capacity: 3.5 AH, Input; 200 V AC Power Supply (certified product) (optional) 1) Battery capacity: 3.5 AH, Input; 100 V AC/200 V AC *Equipment specifications (sub-type) Equipment name Evaluation number Product name Model code Total equipment w eight (w hen in an 83 L container) Extinguishing agent type Extinguishing agent cylinder (internal volume) Extinguishing agent volume (20 C) Extinguishing agent cylinder Cabinet dimensions Cabinet structure Cabinet paint Operating temperature range Operating humidity range Sub-type for 2 pieces AGNS2-8322/6818 Approx. 380 kg IG L (extinguishant container for model 8322), 68 L (extinguishant container for model 6818) 21.8 m 3 ( for an internal volume of 83 L), 17.8 m 3 (for an internal volume of 68 L) Material: CrMo steel, etc., pressure for pressure testing: 50 MPa, paint color: gray W650 D400 H2050 Argonite Amulay 30 Gas evaluation No. 441 Assembly system (hung on the door) Paint color: White (similar to Japan Paint Manufacturers Association TN-85 "1995") -10 C to +40 C 85% or less, non-condensing Sub-type for 3 pieces AGNS3-8322/6818 Approx. 545 kg W950 D400 H

19 Maintenance and inspection record card Customer Manufacturer's serial No. Date installed Inspecting company Telephone No. Telephone No. Maintenance Date inspected Inspector name Customer stamp Remark 6 months Yearly 6 months Yearly 6 months Yearly 6 months Yearly 6 months Yearly 6 months Yearly 6 months Yearly 6 months Yearly 6 months Yearly 6 months Yearly 17

20 Fire-extinguishing Systems and Equipment HATSUTA SEISAKUSHO CO., LTD. 18

Taking a Temperature

Taking a Temperature Taking a Temperature Body heat is measured by taking a temperature with a thermometer. An increase in temperature, called a fever, may be a sign of infection. The common scale used to measure body temperature

More information

PRODUCT NAME. Thermo-dryer MODEL. Original Instructions IDH4-10, IDH4-20, IDHA4-23 IDH6-10, IDH6-20, IDHA6-23

PRODUCT NAME. Thermo-dryer MODEL. Original Instructions IDH4-10, IDH4-20, IDHA4-23 IDH6-10, IDH6-20, IDHA6-23 IDX-OM-V018 1 st edition: December 2017 PRODUCT NAME Thermo-dryer MODEL Original Instructions IDH4-10, IDH4-20, IDHA4-23 IDH6-10, IDH6-20, IDHA6-23 This manual is intended to explain the installation and

More information

Refrigerated Air Dryer

Refrigerated Air Dryer IDX-OM-N030-D 1 st edition: February 2010 6 th edition: March 2012 PRODUCT NAME Refrigerated Air Dryer MODEL Original Instructions IDFA100F-38-, IDFA100F-40- IDFA125F-38-, IDFA125F-40- IDFA150F-38-, IDFA150F-40-

More information

VACUUM PUMP Model VCP-8101

VACUUM PUMP Model VCP-8101 VACUUM PUMP Model VCP-8101 Thank you for choosing the LMS Model VCP-8101 Vacuum Pump. Your Vacuum Pump is CE Certified and designed to be safe, reliable and easy to operate. Please read this thoroughly

More information

PRODUCT NAME. Thermo-dryer MODEL. Original Instructions IDH4-10, IDH4-20, IDHA4-23 IDH6-10, IDH6-20, IDHA6-23

PRODUCT NAME. Thermo-dryer MODEL. Original Instructions IDH4-10, IDH4-20, IDHA4-23 IDH6-10, IDH6-20, IDHA6-23 IDX-OM-O025E-E 1 st edition: December 2010 6 th edition: November 2016 PRODUCT NAME Thermo-dryer MODEL Original Instructions IDH4-10, IDH4-20, IDHA4-23 IDH6-10, IDH6-20, IDHA6-23 This manual is intended

More information

4. Contact arrangement 回路形式 1 poles 1 throws 1 回路 1 接点 (Details of contact arrangement are given in the assembly drawings 回路の詳細は製品図による )

4. Contact arrangement 回路形式 1 poles 1 throws 1 回路 1 接点 (Details of contact arrangement are given in the assembly drawings 回路の詳細は製品図による ) KRT-701 製品仕様書 1/6 1. General 一般事項 1.1 Application 適用範囲 This specification is applied to TACT switches which have no keytop. この規格書は キートッフ なしのタクトスイッチについて適用する 1.2 Operating temperature range 使用温度範囲 : -40

More information

LATEST HEAT PUMP TECHNOLOGIES IN JAPAN. Waseda University Kiyoshi Saito

LATEST HEAT PUMP TECHNOLOGIES IN JAPAN. Waseda University Kiyoshi Saito LATEST HEAT PUMP TECHNOLOGIES IN JAPAN Kiyoshi Saito IEA Heat Pump Conference 217 INTRODUCTION In Japan, since great effort to improve performance of heat pump system has been made, still new technologies

More information

Specification Document. Single-circuit Embedded Water Leakage Detector AD-AS-1BM (RoHS-directive-compatible)

Specification Document. Single-circuit Embedded Water Leakage Detector AD-AS-1BM (RoHS-directive-compatible) To: Specification Document Single-circuit Embedded Water Leakage Detector AD-AS-1BM (RoHS-directive-compatible) Date:( ) System Equipment Division Electronic Materials & System Equipment

More information

Refrigerated Air Dryer

Refrigerated Air Dryer IDX-OM-O006E 1 st edition: May 2011 PRODUCT NAME Refrigerated Air Dryer MODEL IDU15E1-23 (-C,K,L,R,T,V) This manual is intended to explain the installation and operation of the product. Only people who

More information

FOCAS ppm Bilge Alarm. Product Specifications Rev.1.03 (T)

FOCAS ppm Bilge Alarm. Product Specifications Rev.1.03 (T) FOCAS-000 15ppm Bilge Alarm Product Specifications 01-06 Rev.1.03 (T) Alteration / correction hysteretic Date Revision The reason for revision / correction Approved Name 1 01-01-18 Rev.1.01 Internal Arrangement

More information

IDX-OM-H006-I Initial issue: January th edition : November Operation Manual. Refrigerated Air Dryer. Series

IDX-OM-H006-I Initial issue: January th edition : November Operation Manual. Refrigerated Air Dryer. Series IDX-OM-H006-I Initial issue: January 2004 9th edition : November 2011 Operation Manual Refrigerated Air Dryer Series IDF1E-10 IDF2E-10 IDF3E-10 IDF3E-20 IDF4E-10 IDF4E-20 IDF6E-10 IDF6E-20 IDF8E-10 IDF8E-20

More information

Surface Mount Type. Outline Dimensions 外形寸法図. Surface Mount Type LED

Surface Mount Type. Outline Dimensions 外形寸法図. Surface Mount Type LED Surface Mount Type NFWG-VF, NFWG-VF, NFSWG-V, NFSWG-V,NTx(W,L)G-V, NFSWG-P, NTx(W,L)GR-V, NFx(W,L)GR-V, NFx(W,L)GR-VU, NFx(W,L)G-F, NFSx(W,L)G, NFLGR, NEx(G,B)G,NERG-P,NFSYG, NFEGR.0 NFLDR-VM, NFSWD-VM,

More information

Safety Precautions 安全上の注意

Safety Precautions 安全上の注意 Safety Precautions 安全上の注意 English Foreword... For safe operation...3 Position of the warning label...7 日本語 はじめに... 0 安全にお使いいただくために... 警告ラベルについて... 4 MIMAKI ENGINEERING CO., LTD. https://mimaki.com/ D0906-3

More information

To Purchase This Item, Visit BMI Gaming (800) Super Scooper OPERATION MANUAL

To Purchase This Item, Visit BMI Gaming   (800) Super Scooper OPERATION MANUAL Super Scooper OPERATION MANUAL INTRODUCTION Thank you for purchasing the Super Scooper game machine (hereafter referred to as the machine ). This Operation Manual describes: How to install, operate, relocate,

More information

RAS-DX18HDK/RAC-DX18HDK

RAS-DX18HDK/RAC-DX18HDK RAS-DX18HDK/RAC-DX18HDK RAC-DX18HDK RAS-DX18HDK 1 22 23 44 - 2 - - 3 - 18 FILTER LAMP Light indicator showing that it is time to clean the filter. 15 RAS-DX18HDK 1050 290 220 RAC-DX18HDK 792 420 299-4

More information

Operation Manual. Original Instructions PRODUCT NAME. Refrigerated Air Dryer. MODEL / Series

Operation Manual. Original Instructions PRODUCT NAME. Refrigerated Air Dryer. MODEL / Series IDFA3E-TFK17GB-A IDX-OM-I070-G Initial issue December, 2004 7th edition November, 2011 Operation Manual Original Instructions PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDFA3E-23-A,C IDFA4E-23-A,C,L,R,T,V

More information

Zero Internal Heating/Cooling Load Air-Conditioning system

Zero Internal Heating/Cooling Load Air-Conditioning system Zero Internal Heating/Cooling Load Air-Conditioning system Study on Indoor Thermal Environment of an Office Room with the Liquid Cooling Air-conditioning System Li Wang (University of Tokyo, Japan) (leowang19861986@gmail.com)

More information

Tsukuba Life Handbook つくばでの生活ガイド

Tsukuba Life Handbook つくばでの生活ガイド Tsukuba Life Handbook つくばでの生活ガイド Short-term stay 短期滞在 High Energy Accelerator Research Organization Users Office エネルギー加速器研究機構ユーザーズオフィス 2018.5.29 KEK Users Office Emergency Procedures 緊急時の対応 順 Inside of

More information

Nichia STS-DA <Cat.No > SPECIFICATIONS FOR NICHIA UV NSHU591A MODEL : NICHIA CORPORATION

Nichia STS-DA <Cat.No > SPECIFICATIONS FOR NICHIA UV NSHU591A MODEL : NICHIA CORPORATION SPECIFICATIONS FOR NICHIA UV LED MODEL : NSHU591A 1.SPECIFICATIONS (1) Absolute Maximum Ratings (Ta=25 C) Item Symbol Absolute Maximum Rating Unit Forward Current IF 25 ma Pulse Forward Current IFP 80

More information

Electrical Appliances and Materials Safety Act Statutory Operations Implementation Guide. 3rd version

Electrical Appliances and Materials Safety Act Statutory Operations Implementation Guide. 3rd version Electrical Appliances and Materials Safety Act Statutory Operations Implementation Guide ~ For Manufacturers/Importers ~ 3rd version Marking for Specified Electrical Appliances and Materials Marking for

More information

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4 PREMIER EX8 EXTINGUISHING PANEL USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN 12094 PART 1 & EN54 PARTS 2 & 4 USER MANUAL Approved Document No: GLT.MAN-132 INDEX Extinguishing

More information

User Operation Manual

User Operation Manual APPROVED BY: JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL User Operation Manual PAGE 1 of 6 1 CONTENTS 1. FIRE - GENERAL... 3 2. FIRE - ZONES 1 OR 2 - AUTOMATIC MODE... 3 3. FIRE - ZONES

More information

R-S32EPH R-S32EPHL

R-S32EPH R-S32EPHL R-S32EPH R-S32EPHL 8 8 9 9 17 10 12 12 13 13 13 16 16 17 17 17 Tank Empty Child Lock (Press 5 Sec.) Eenergy Cooling Mode ON Ice OFF Maker Max. Mid. Min. Max. Mid. Cooling Min. Preparations before Use

More information

K-Band Doppler Sensor Module

K-Band Doppler Sensor Module Released K-Band Doppler Sensor Module RF Frequency: 24.05 to 24.25 GHz Model No. NJR4265R series Frequency Line-up: Software Version: F1: 24.05 to 24.25 GHz F2: 24.15 to 24.25 GHz F3: 24.075 to 24.175

More information

Refrigerated Air Dryer

Refrigerated Air Dryer IDX-OM-J034-E Initial issue: March, 2006 5th edition: March, 2011 PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDF22E-20 IDF22E-30 IDF37E-20 IDF37E-30 IDF55E-30 IDF75E-30 Please read this manual

More information

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00 PAT E N T System 88 COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00 Pg 1 of 12 CONTENTS 1. GENERAL 1.1 Introduction 2 1.2 System Description

More information

WARNING/CAUTION DESCRIPTION OF COMPONENTS FUNCTION EXPLANATION OPERATION INSTRUCTIONS CONTINUOUS DRAINAGE CAUTIONS MAINTENANCE/EMERGENCY

WARNING/CAUTION DESCRIPTION OF COMPONENTS FUNCTION EXPLANATION OPERATION INSTRUCTIONS CONTINUOUS DRAINAGE CAUTIONS MAINTENANCE/EMERGENCY 抽濕機 使用說明書 PDN20S WARNING/CAUTION DESCRIPTION OF COMPONENTS FUNCTION EXPLANATION OPERATION INSTRUCTIONS CONTINUOUS DRAINAGE CAUTIONS MAINTENANCE/EMERGENCY SPECIFICATION 1 2 3 4 5 6 7 WARNING CAUTION 1

More information

CONTENTS Introduction and Characteristics. 1 Fire Alarm System Assembly Diagram.. 2 Fire Alarm Signal Flow Chart.. 2 Panel Descriptions 3 Standard

CONTENTS Introduction and Characteristics. 1 Fire Alarm System Assembly Diagram.. 2 Fire Alarm Signal Flow Chart.. 2 Panel Descriptions 3 Standard CONTENTS Introduction and Characteristics. 1 Fire Alarm System Assembly Diagram.. 2 Fire Alarm Signal Flow Chart.. 2 Panel Descriptions 3 Standard Detector Wiring Method. 4 Method of Wiring.. 5 Wiring

More information

INSTALLATION GUIDE. AXIS T8008 PS12 Power Supply

INSTALLATION GUIDE. AXIS T8008 PS12 Power Supply INSTALLATION GUIDE AXIS T8008 PS12 Power Supply Legal Considerations Video surveillance can be regulated by laws that vary from country to country. Check the laws in your local region before using this

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE AIR CONDITIONER INDOOR UNIT/OUTDOOR UNIT MODEL RAS-260GA/RAC-260GA RAS-350GA/RAC-350GA OUTDOOR UNIT INDOOR UNIT RAC-260GA RAS-260GA RAS-350GA RAC-350GA Instruction manual Page 1~24 To obtain

More information

INSTRUCTION MANUAL FOR

INSTRUCTION MANUAL FOR INSTRUCTION MANUAL FOR Cool Block The 1st Edition Yamato Scientific Co.,, Ltd. 2-1-6, Nihonbashi Honcho, Chuo-ku Tokyo 103-8432 JAPAN Congratulations on your selection of Yamato Scientific s Cool Block

More information

(Cabinet Automatic Fire Extinguishing System)

(Cabinet Automatic Fire Extinguishing System) (Cabinet Automatic Fire Extinguishing System) For your safety and proper use of this equipment, please read carefully and understand the contents of this manual. Return or keep this manual in its designated

More information

NSPU510CS Built-in ESD Protection Device RoHS Compliant

NSPU510CS Built-in ESD Protection Device RoHS Compliant NICHIA CORPORATION SPECIFICATIONS FOR UV LED NSPU510CS Built-in ESD Protection Device RoHS Compliant SPECIFICATIONS (1) Absolute Maximum Ratings Item Symbol Absolute Maximum Rating Unit Forward Current

More information

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD Corona Corporation This instruction manual contains important information for safe use of this device. Keep this instruction manual

More information

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump R 410A Ductless Split System Air Conditioner and Heat Pump Models DLC4(A/H) Outdoor Unit, DLF4(A/H) Indoor Unit Sizes 9K, 12K, 18K, 24K, 30K and 36K Please read the operating instructions and safety precautions

More information

開会のあいさつ. Opening Address 東京大学生産技術研究所所長教授野城智也. Tomonari Yashiro Director General, Professor Institute of Industrial Science The University of Tokyo

開会のあいさつ. Opening Address 東京大学生産技術研究所所長教授野城智也. Tomonari Yashiro Director General, Professor Institute of Industrial Science The University of Tokyo 第 5 回技術フォーラム 東日本大震災とエネルギーの動向 --- 課題と革新的解決策 --- Technical Forum organized by IIS, the University of Tokyo Great East Japan Earthquake Disaster and the Future Trend of Energy in Japan ---Lessons Learnt and

More information

Version 1.03 January-2002 USER S MANUAL

Version 1.03 January-2002 USER S MANUAL Version 1.03 January-2002 1 USER S MANUAL 2 Version 1.03 January-2002 System Details CUSTOMER:...... PHONE:... FAX:... INSTALLED BY:...... PHONE:... FAX:... MAINTENANCE & SERVICE:...... PHONE:... FAX:...

More information

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock. Preface Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock. The GSM Security Alarm ( The Alarm ) adopts the most advanced

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE INDOOR UNIT/OUTDOOR UNIT MODEL RAS-0EX9K/RAC-0EX9 RAS-3EX9K/RAC-3EX9 OUTDOOR UNIT INDOOR UNIT RAC-0EX9 RAS-0EX9K RAS-3EX9K RAC-3EX9 Instruction manual Page ~36 To obtain the best performance

More information

同志社大学留学生宿舎申込書 (2010 年度 ) Application for Accommodation for International Students (2010) Doshisha University Center for Japanese Language and Culture

同志社大学留学生宿舎申込書 (2010 年度 ) Application for Accommodation for International Students (2010) Doshisha University Center for Japanese Language and Culture 同志社大学留学生宿舎申込書 (2010 年度 ) Application for Accommodation for International Students (2010) Doshisha University Center for Japanese Language and Culture 1. 氏名 Full name, (in Roman letters) 漢字 姓 Family 名 First

More information

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual ZX1e ZX2e ZX5e Document No. 996-130 Issue 01 user manual MORLEY-IAS ZX2E/ZX5E Fire Alarm Control Panels Table of Contents 1 INTRODUCTION... 4 1.1 NOTICE... 4 1.2 WARNINGS AND CAUTIONS... 4 1.3 NATIONAL

More information

Formulating Time Tested Knowledge for Sustainable Disaster Risk Reduction; A Case Study of Kathmandu

Formulating Time Tested Knowledge for Sustainable Disaster Risk Reduction; A Case Study of Kathmandu 京都大学防災研究所年報第 52 号 B 平成 21 年 6 月 Annuals of Disas. Prev. Res. Inst., Kyoto Univ., No. 52 B, 2009 Formulating Time Tested Knowledge for Sustainable Disaster Risk Reduction; A Case Study of Kathmandu Roshan

More information

Operation Manual PRODUCT NAME. Refrigerated Air Dryer. MODEL / Series

Operation Manual PRODUCT NAME. Refrigerated Air Dryer. MODEL / Series IDX-OM-H006-H Initial issue: January 2004 8th edition : November 2010 Operation Manual PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDF1E-10 IDF2E-10 IDF3E-10 IDF3E-20 IDF4E-10 IDF4E-20 IDF6E-10

More information

SPLIT TYPE. Instruction manual

SPLIT TYPE. Instruction manual SPLIT TYPE Instruction manual ENGLISH Instruction manual Page 1~24 To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely. 1 SAFETY PRECAUTION

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE AIR CONDITIONER INDOOR UNIT/OUTDOOR UNIT ENGLISH MODEL RAS-50YHA/RAC-50YHA OUTDOOR UNIT INDOOR UNIT RAC-50YHA RAS-50YHA Instruction manual Page 1~26 To obtain the best performance and ensure

More information

Control Panels Variable Frequency Drives Float Switches Alarm Systems For Water/Wastewater Pump and Motor Control. Visit worldwide link at

Control Panels Variable Frequency Drives Float Switches Alarm Systems For Water/Wastewater Pump and Motor Control. Visit worldwide link at Control Panels Variable Frequency Drives Float Switches Alarm Systems For Water/Wastewater Pump and Motor Control Visit worldwide link at www.sjerhombus.com 22650 County Highway 6 PO Box 1708 Detroit Lakes,

More information

パルスヒートユニットシリーズ. Pulse Heat Unit Series

パルスヒートユニットシリーズ. Pulse Heat Unit Series パルスヒートユニットシリーズ Pulse Heat Unit Series Pulse Heat Unit Series Avio パルスヒートユニットの概要 日本アビオニクス株式会社のパルスヒートユニットは 電子機器や電子部品の製造におけるはんだ付け ACF 圧着 樹脂溶着 熱圧着の分野において長年ご好評をいただいております 近年 モバイル機器をはじめとする電子機器は機能 性能ともに進化が加速しています

More information

Visit worldwide link at

Visit worldwide link at Control Panels n Variable Frequency Drives Float Switches n Alarm Systems For Water/Wastewater Pump and Motor Control Visit worldwide link at www.sjerhombus.com 22650 County Highway 6 n PO Box 1708 n Detroit

More information

NSHU591B Built-in ESD Protection Device RoHS Compliant

NSHU591B Built-in ESD Protection Device RoHS Compliant NICHIA CORPORATION SPECIFICATIONS FOR UV LED NSHU591B Built-in ESD Protection Device RoHS Compliant SPECIFICATIONS (1) Absolute Maximum Ratings Item Symbol Absolute Maximum Rating Unit Forward Current

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum

More information

Control Panel User Guide

Control Panel User Guide Fire Detection & Alarm System Control Panel V4.14 Control Panel User Guide (TO BE RETAINED BY USER) 26-0397 Issue 6 Fike s policy is one of continual improvement and the right to change a specification

More information

INTEGRATED VOICE EVACUATION SYSTEM VX-3000 SERIES

INTEGRATED VOICE EVACUATION SYSTEM VX-3000 SERIES PLEASE READ THIS MANUAL FIRST! INTEGRATED VOICE EVACUATION SYSTEM VX-3000 SERIES Thank you for purchasing TOA s Integrated Voice Evacuation System. Please carefully follow the instructions in this manual

More information

Wireless Remote Controller Kit

Wireless Remote Controller Kit OPERATION MANUAL Wireless Remote Controller Kit L BRC7E88 Read these instructions carefully before installation. Keep this manual in a handy place for future reference. This manual should be left with

More information

Earthquake Early Warning and Realtime Disaster Prevention

Earthquake Early Warning and Realtime Disaster Prevention Earthquake Early Warning and Realtime Disaster Prevention Yutaka NAKAMURA, Dr. Eng. System and Data Research, Co., Ltd. Visiting Professor, 1 Videos Recorded at the Moment of Earthquake Attack 2 EEW and

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE AIR CONDITIONER ENGLISH INDOOR UNIT/OUTDOOR UNIT MODEL RAS-51CHA3/RAC-51CHA3 RAS-63CHA3/RAC-63CHA3 OUTDOOR UNIT INDOOR UNIT RAS-51CHA3 RAS-63CHA3 RAC-51CHA3 RAC-63CHA3 Instruction manual Page

More information

Weekly Wired Remote Controller

Weekly Wired Remote Controller LG LG Weekly Wired Remote Controller Owner's & Installation Manual Models: PCRCUSZ0 PDRCUSZ0 IMPORTANT Please read this installation manual completely before installing the product. Installation work must

More information

タイ工業規格 (TIS) の概要と認証マークの取得について

タイ工業規格 (TIS) の概要と認証マークの取得について タイ工業規格 (TIS) の概要と認証マークの取得について 2018 年 3 月 日本貿易振興機構 ( ジェトロ ) バンコク事務所 貿易制度課 報告書の利用についての注意 免責事項 本報告書は 日本貿易振興機構 ( ジェトロ ) バンコク事務所が現地調査会社 TK Wise Group Co., Ltd. に委託し 2018 年 2 月に入手した情報に基づき作成したものであり その後の法律改正などによって情報が変わる場合があります

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS* A09LEC AS* A12LEC AO* R09LECN AO* R12LECN R410A CONTENTS 1. DESCRIPTION OF EACH CONTROL

More information

Instruction Manual for Electric Ovens OO757X OO986X

Instruction Manual for Electric Ovens OO757X OO986X Instruction Manual for Electric Ovens OO757X OO986X 1 2 DEAR CUSTOMER, We thank you and congratulate you on your choice. This new carefully designed product, manufactured with the highest quality materials,

More information

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump R-10A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFF(A/H)H, DFC(A/H) Please read the operating instructions and safety precautions carefully and thoroughly before installing and

More information

PERSONS NEEDING ASSISTANCE who are unable to quickly walk down the exit stairwells should follow these alternative procedures:

PERSONS NEEDING ASSISTANCE who are unable to quickly walk down the exit stairwells should follow these alternative procedures: LANSDOWNE WOODS EMERGENCY ACTION PLAN FOR RIVERBEND AT LEISURE WORLD (passed November 30, 2011) INTRODUCTION The information contained in this section is for the use of all Riverbend residents in the event

More information

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01 OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01 Table of Contents Safety Instructions 4 Owner/Operator Responsibility 4 Specifications 5 Introduction 6 Installation Instructions 7 Setup 7 Wiring

More information

Wall-Mount Enclosures: Standard and NEMA

Wall-Mount Enclosures: Standard and NEMA Wall-Mount Enclosures: Standard and NEMA For Model 106 Ozone Monitors 2B Technologies, Inc. INSTALLATION MANUAL Copyright 2017, 2B Technologies, Inc. All rights reserved. Technical Support: www.twobtech.com/techsupport

More information

Weekly Wired Remote Controller

Weekly Wired Remote Controller LG LG Weekly Wired Remote Controller Owner's & Installation Manual Models: PVRCUSZ0 IMPORTANT Please read this installation manual completely before installing the product. Installation work must be performed

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE INDOOR UNIT/OUTDOOR UNIT MODEL RAS-80YHA/RAC-80YHA INDOOR UNIT OUTDOOR UNIT RAS-80YHA RAC-80YHA Instruction manual Page 1~22 To obtain the best performance and ensure years of trouble free use,

More information

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit RAS-10, 13, 18, 24, 30BKS-HK

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit RAS-10, 13, 18, 24, 30BKS-HK OWNER S MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit RAS-0,, 8, 24, 0BKS-HK Outdoor unit RAS-0,, 8, 24, 0BAS-HK 065560 065560_EN.indd 9/0/2558 BE 5:07 PRECAUTIONS FOR

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE INDOOR UNIT/OUTDOOR UNIT MODEL RAS-72CHA3/RAC-72CHA3 INDOOR UNIT OUTDOOR UNIT RAS-72CHA3 RAC-72CHA3 Instruction manual Page 1~22 To obtain the best performance and ensure years of trouble free

More information

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL MODEL RA-0LDF RA-3LDF WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL AIR DEFLECTORS VERTICAL DEFLECTORS Vertical de ectors at both sides of outlets can be set to either auto-swing or

More information

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use. Indoor unit 42TVU010, 012, Outdoor unit 38TVU010, 012, ENGLISH

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use. Indoor unit 42TVU010, 012, Outdoor unit 38TVU010, 012, ENGLISH OWNER S MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit 4TVU00, 0, 08-70 Outdoor unit 8TVU00, 0, 08-70 0508 PRECAUTIONS FOR SAFETY DANGER Do not install, repair, open or

More information

Ducted air conditioner Operating Manual

Ducted air conditioner Operating Manual KLIMA Ducted air conditioner Operating Manual Note: Before using the Air Conditioner please read the safety instructions to ensure correct operation of the unit. 1 CONTENTS 1. Safety precautions---------------------------------------------------------------------------3-4

More information

WIRED REMOTE CONTROLLER

WIRED REMOTE CONTROLLER WIRED REMOTE CONTROLLER OPERATION MANUAL BRCE6 Thank you for purchasing this product. This manual describes safety precautions required for the use of the product. Read this manual carefully and be sure

More information

Sentry Equipment Cabinet Environmental Monitor

Sentry Equipment Cabinet Environmental Monitor Server Technology Solutions for the Data Center Equipment Cabinet Sentry Equipment Cabinet Environmental Monitor - EMCU-1-1 2003-2005 Server Technology, Inc. All rights reserved. Instructions This symbol

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE INDOOR UNIT/OUTDOOR UNIT ENGLISH MODEL RAS-70YHA / RAC-70YHA OUTDOOR UNIT INDOOR UNIT RAC-70YHA RAS-70YHA Instruction manual Page 1~23 To obtain the best performance and ensure years of trouble

More information

User s Information Guide R2A

User s Information Guide R2A Pi HSC505 Home Security Controller User s Information Guide R2A Page 1 of 15 of its development program. 1This document and product are copyrighted and all rights are reserved. Introduction Convention

More information

Buzzer Unit. TAN-5000 Series. Operating Manual

Buzzer Unit. TAN-5000 Series. Operating Manual PT1E-1040 Buzzer Unit TAN-5000 Series Operating Manual Request for the Customers Read and understand this operating manual before using the buzzer unit. Use the buzzer unit in accordance with the operating

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS*G4LFCA AS*G4LFCC AS*G0LFCA AO*G4LFL AO*G4LFCC AO*G0LFT R40A CONTENTS. DESCRIPTION OF EACH

More information

Security System. User s Guide for the Text Command Center

Security System. User s Guide for the Text Command Center User s Guide for the Text Command Center MY ALARM COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY CONTROL PANEL IS CONNECTED TO THE PHONE JACK LOCATED:

More information

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS*G09LTCB AS*GLTCB AS*G4LTCB AO*G09LTCN AO*GLTCN AO*G4LTCN R40A CONTENTS. DESCRIPTION OF EACH

More information

Water Leakage Location Detector AD-AS-1LCM-A Operation Manual

Water Leakage Location Detector AD-AS-1LCM-A Operation Manual TTS-KS-W500- Water Leakage Location Detector AD-AS-LM-A peration Manual TATSUTA lectric Wire & able o., Ltd. lectronics Division System Department Warning rroneous

More information

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

Operation Manual. Refrigerated Air Dryer

Operation Manual. Refrigerated Air Dryer IDX-OM-J001-D Initial issue April, 2005 4th edition July, 2007 Operation Manual Refrigerated Air Dryer IDFB3E-11 -A IDFB4E-11 -A,R,T,V IDFB6E-11 -A,K,R,T,V IDFB8E-11 -A,K,R,T,V IDFB11E-11 -A,K,R,T,V IDFB15E-11

More information

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner F566113 Operating Instructions Air Conditioner Indoor Unit CS-E18HKR CS-E1HKR CS-E4HKR CS-E8HKR Outdoor Unit CU-E18HKR CU-E1HKR CU-E4HKR CU-E8HKR Before operating the unit, read these operating instructions

More information

AIR CONDITIONER (SPLIT TYPE)

AIR CONDITIONER (SPLIT TYPE) OWNER S MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit RAS-0, 22, 24NKCV(HK) Outdoor unit RAS-0, 22, 24NACV- 065557 PRECAUTIONS FOR SAFETY DANGER Do not install, repair,

More information

GAS SUPRESSION CONTROL PANEL:

GAS SUPRESSION CONTROL PANEL: GAS SUPRESSION CONTROL PANEL: MODEL NAME: COMPANY: DELTA 437/2, Main Road, Mandwali Fazalpur, Delhi-110092 Page 1 ABOUT THE PRODUCT ASES is very proud of to introduce DELTA the completely digital microprocessor

More information

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 Indoor unit service manual MSZ-DM VA Series (OBH750) CONTENTS 1. TECHNICAL CHANGES 2 2. PART NAMES

More information

CITY MULTI Control System and Mitsubishi Air Conditioners Wireless Remote Controller PAR-SL100A-E

CITY MULTI Control System and Mitsubishi Air Conditioners Wireless Remote Controller PAR-SL100A-E CITY MULTI Control System and Mitsubishi Air Conditioners Wireless Remote Controller PAR-SL100A-E OPERATION MANUAL FOR USER For safe and correct use, please read this operation manual thoroughly before

More information

Low-Profile Pyranometer ML-02

Low-Profile Pyranometer ML-02 INSTRUCTION MANUAL Low-Profile Pyranometer ML-02 1. Index 1. Index 1 2. Important User Information 2 2-1. Contact Information 2 2-2. Warranty and Liability 2 2-3. About Instruction Manual 3 2-4. Environment

More information

Mitsubishi HEMS. Mitsubishi Electric Smart House Solution

Mitsubishi HEMS. Mitsubishi Electric Smart House Solution Mitsubishi HEMS Pillars of Mitsubishi HEMS Product Development Support energy conservation Usable by everyone Energy conservation and comfort Support energy conservation (1) Easy-to-understand visualization

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

Service Bulletin No. 2930

Service Bulletin No. 2930 Service Bulletin No. 2930 MODEL TYPE SECTION/GROUP DATE E / J Series Coaches Service Information 8--Engine Mar. 30, 2006 SUBJECT AMEREX FIRE SUPPRESSION SYSTEM CONDITIONS Service Information Only Description:

More information

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner F56579 Operating Instructions Air Conditioner Indoor Unit Outdoor Unit CS-E18GKR CS-E1GKR CS-E4GKR CS-E8GKR CU-E18GKR CU-E1GKR CU-E4GKR CU-E8GKR Before operating the unit, read these operating instructions

More information

Owner's Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS 40MAQ High Wall Ductless System Sizes 09 to 36 Owner's Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PART NAMES... 3 FUNCTION BUTTONS... 4 DISPLAY PANELS... 5 REMOTE CONTROL... 6

More information

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF AOU 9RLFW AOURLFW R40A CONTENTS. DESCRIPTION OF EACH CONTROL OPERATION. COOLING

More information

OPERATING INSTRUCTIONS VOICE EVACUATION SYSTEM FS-7000 SERIES

OPERATING INSTRUCTIONS VOICE EVACUATION SYSTEM FS-7000 SERIES OPERATING INSTRUCTIONS VOICE EVACUATION SYSTEM FS-7000 SERIES Thank you for purchasing TOA's Voice Evacuation System. Please carefully follow the instructions in this manual to ensure long, trouble-free

More information

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3 INTELLIGENT FIRE TECHNOLOGY Twinflex and Multipoint V3 User Guide (TO BE RETAINED BY USER) 26-0340 Issue 3 Rafiki Protection Limited Rafiki policy is one of continual improvement and the right to change

More information

International Catalog

International Catalog International Catalog Control Panels n Variable Frequency Drives Float Switches n Alarm Systems For Water/Wastewater Pump and Motor Control Visit worldwide link at www.sjerhombus.com 22650 County Highway

More information

DEHUMIDIFYING DRYER DMZ 2-40~120U. Instruction Manual

DEHUMIDIFYING DRYER DMZ 2-40~120U. Instruction Manual DEHUMIDIFYING DRYER DMZ 2-40~120U Instruction Manual WARNING Thank you for purchasing our dryer. Please use your DEHUMIDIFYING DRYER only after thoroughly reading this manual. Keep this manual near the

More information

GT-1D. Residential/Tenant Station OPERATION MANUAL

GT-1D. Residential/Tenant Station OPERATION MANUAL GT-1D Residential/Tenant Station SERVICE MANUAL OPERATION MANUAL Table of Contents PRECAUTIONS...2 1 NAMES AND FUNCTIONS...2 2 OPERATION 2-1 Answering a call...3 2-2 Calling from the doorbell button...3

More information