Safety control unit 471 M41 H31. for 4 to 32 sensors, with safety and control outputs. Use. Models. + PLe according to EN ISO
|
|
- Charles Mitchell
- 5 years ago
- Views:
Transcription
1 Safety control unit for 4 to 32 sensors, with safety and control outputs 471 M41 H31 + PLe according to EN ISO Four safety outputs (two separate safety circuits each with two safety outputs) + Separate control outputs for further processing + Emergency stop function with short-circuit detection + Suitable for 2-hand control + Connection via codable, screwless terminals + Available as an option with double terminals + LED status display + Adjustable delay times for safety output 4 + Suitable for sensors with 2 NO system, input 4 also suitable for NO/NC system + Monitoring of the contactor externally Use The control unit is for evaluating signals from machine safety sensors. Due to the variable design, the inputs can be used for a variety of functions, such as 2-hand control or for connecting an emergency stop button. Models The 471 M41 H31 enables the connection of a sensor in 3- as well as 4-wire technique. The 4-wire technique also allows a cross short detection. At sensor input 4, a sensor with 2-contact makers as well as a contact maker/breaker system can be connected. Further parameters, such as the delay time, can be configured by a DIP switch. The connection terminals are available as an option and also as double terminals (1.5 mm²). Page 1 of 8
2 Mechanical assembly Installation dimensions Housing 120 x 100 x 45 mm (without terminals) 120 x 130 x 45 mm (with terminals) Installation On TH35 hat rails according to DIN EN Key mechanical data Technology Control unit for 4 to 32 external safety sensors* Material PA (polyamide) Weight Approx. 370 g (depending on version) Working temperature range 0 to +55 C Storage temperature range -25 to +85 C International protection IP30 DIN EN Colour Black * 4 sensors can be connected directly, up to 32 via additional interfaces s 2-hand control Cooling-off period 3 s 0,5 s Page 2 of 8
3 Approvals and safety key data Safety key data SIL CL 3 (EN IEC 62061) PLe (EN ISO ) Category 4 (EN / EN ISO ) PFH d 1.70e -8 1/h (EN IEC 62061) 20 year operating life Approvals ETL CAN/ESA C22.2#14, ANSI/UL 508 Key electrical data Operating voltage 24 V DC ± 15 % Power consumption Status display 850 ma 10 x LED Safety outputs Control outputs Switching voltage 30 V AC/DC 24 V DC Switching current 3 A AC/DC 100 ma Switching capacity 90 VA/W 2.4 VA/W Connection 24 V DC Input Logic Output 1 2 &/ Safety Shown in de-energised state. s are not actuated. K1 K2 2 5 external contactor K3 K Start-Push- Button/ external contactor & Control 1 +U B Control 2 Safety Control 3 +U B Control 4 Ready Power UB PLC PLC K4 K3 K2 K1 Page 3 of 8
4 Connection type Connection terminal Double terminal (optional) mm² mm² The plug-in, screwless terminals can be coded using coding pins so that if the device is replaced, the connectors cannot be confused during installation. Double terminals are also available as an option (see adjacent figure). The 471 M41 H31 consists of two independent units: Shown with double terminal Unit 1 input 1 For sensors with 2 NO system input 2 For sensors with 2 NC system Can also be used as 2-hand control Safety output 1 Controlled in parallel by sensor inputs Safety output 2 Controlled in parallel by sensor inputs External contactor For monitoring the external contactors Control output 1 Output sensor 1, switched state Control output 2 Output sensor 2, switched state Unit 2 input 3 For sensors with 2 NO system input 4 For sensors with 2 NC system For sensors with NO/ NC system For 3 or 4 wire technique For operating an emergency stop button Safety output 3 Controlled in parallel by sensor inputs Safety output 4 Controlled in parallel by sensor inputs Delay time can be adjusted (0-15 seconds), as opposed to safety output 3 External contactor For monitoring the external contactors For S4 emergency off: it is advisable to include a start button Control output 3 Output sensor 3, switched state Control output 4 Output sensor 4, switched state Remarks In the event of emergency off in 4 wire technique: cross short detection 2-hand control, simultaneous emergency stop and sensor(s) possible Separate output available for standby Page 4 of 8
5 You can set the options using the DIP switch. This is located under the top cover. You can read the input and output status with the following LEDs. LED 1 Operating voltage LED 6 4 LED 2 Standby LED 7 Safety output 1 LED 3 1 LED 8 Safety output 2 LED 4 2 LED 9 Safety output 3 LED 5 3 LED 10 Safety output 4 Switch 1 Switch 2 Switch 3 Switch 4 Switch 5 Switch 6 Switch 7 Switch 8 8 second delay 4 second delay 2 second delay 1 second delay Safety sensor 4: contact breaker / maker 2-hand control Safety sensor 4: 3 or 4 wire No function Four safety sensors can be connected directly to the control unit. Using the following elobau interfaces, the monitoring can be extended by up to 32 safety sensors: 363 V Page 5 of 8
6 See the two examples below for connections with the switches for the operating model: 2-hand control, sensor and emergency stop with cross short detection: 1 st hand 2 nd hand Standby Safety output 1 Safety output 2 Output S1 External contactor Output S2 Safety output 3 Emergency stop External contactor Safety output 4 Output S3 Output S4 Switches for operating versions The turn-off delay of safety output 4 can be set via switch 1 to 4. See example here for 4 seconds. Start Cross short safety: emergency stop messages appear via two contact breakers which are impacted by various potentials. This allows cable short circuits to be detected. Circuit diagram shown in de-energised state. not actuated. Page 6 of 8
7 Connection with interface : Safety output 1 Safety output 2 Output S1 External contactor Output S2 Safety output 3 24 VDC power supply Safety output 4 Output S3 External contactor Output S4 1 Control output Elec. sensor connection Control output 2 Control output 3 4 Control output 4 Switch settings for options Shown in de-energised state. /s not actuated. Page 7 of 8
8 Fax: +49 (0) Your product enquiry Quantity Batch size Name/first name Company Address Postal code/town Country Å Æ Notes, questions, other Page 8 of 8
1.7. Insulation fault evaluators EDS460/490 EDS461/491
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 06401 807-0 Fax: 06401 807-59 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control
More informationISIS SAFETY SYSTEM Installation guide
ISIS SAFETY SYSTEM Installation guide CAUTION This information is designed to help suitably qualified personnel install and operate Mechan Safety equipment. Before using this product, read this guide thoroughly
More informationSafety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS
Safety Control Modules for Emergency Stop Circuits TYPICAL APPLICATIONS APPROVALS DIMENSIONS Single Channel Emergency Stop Module E-Stop circuits up to Category 2 (EN 954-) Sliding door protection Conveyors
More informationEngineering Guideline. pac- Carriers Type Universal
Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art
More informationDatasheet - MZM 100 ST-SD2PREM-A
19.03.2014-10:31:42h Datasheet - MZM 100 ST-SD2PREM-A Solenoid interlock / MZM 100 Preferred typ Guard locking monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating
More information1.7. Insulation fault evaluators EDS460/490 EDS461/491
Bender Incorporated 700 Fox Chase, Coatesville PA 1930 Tel.: (800) 356-466 Fax: (610) 383-7100 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control function
More informationDatasheet - MZM 100 B ST2-SD2PREM-A
30.05.2015-14:46:12h Datasheet - MZM 100 B ST2-SD2PREM-A Solenoid interlock / MZM 100 Preferred typ Actuator monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating
More informationSafety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)
Safety Temperature Limiter STL 50 Certified to DIN EN 14597 (replaces DIN 3440) Features M For use as: STB Protection - temperature limiter ASTB Exhaust gas - protection - temperature limiter STW Protection
More informationDatasheet - MZM 100 ST2-1P2PWREM-A
30.05.2015-14:45:08h Datasheet - MZM 100 ST2-1P2PWREM-A Solenoid interlock / MZM 100 Preferred typ Guard locking monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating
More informationM2500 Engine Controller Installation Manual
M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...
More informationDEB71. Earth Leakage Monitoring Relay. Benefits. Description
Earth Leakage Monitoring Relay Benefits Adjustable trip level. Adjustable leakage threshold from 30mA to 5A or from 300mA to 30A. 2 outputs. Two relay outputs provide, besides the alarm signal an additional
More informationEngineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS
Engineering Guideline pac-carriers Type 9195 for Yokogawa ProSafe-RS 2 Engineering Guideline / Yokogawa ProSafe-RS 06.06.2017 Integrated solutions for Yokogawa R. STAHL offers a wide range of customized
More informationUniversal fault annunciator for panel mounting
Universal fault annunciator for panel mounting Communication over Ethernet USM - Universal-fault annunciator for panel mounting Low depth housing for panel mounting Versions with 8, 16, 32 or 48 inputs
More informationLINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems
LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016 LINETRAXX RCMA420 Residual current monitor for monitoring AC,
More informationOperating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content
8 Appendix 8.1 Wiring examples...4 8.2 Start configuration...4 8.3 Sensor configuration...4 8.4 Actuator configuration...5 Operating instructions.............pages 1 to 6 Original 9 EU Declaration of conformity
More informationOperating Manual MS220KA and MSR220KA
Temperature Relays and MINIKA, Mains Monitoring, Digital Panel meters MINIPAN, Switching Relays and Controls Operating Manual MS220KA and MSR220KA ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße
More informationIndex Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:
Systems Index Systems - Systems Systems...1 -.16 General information Description...1 System description...2 Overview...3 Ordering details Arc monitor with detectors...4 Current sensing unit...5 Technical
More informationISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)
ISOMETER IR425 Insulation monitoring device for unearthed AC/DC control circuits (IT systems) IR425-D4_D00039_04_D_XXEN/05.2017 ISOMETER IR425 Insulation monitoring device for unearthed AC/DC control circuits
More informationSAFETY INTERFACES SAFETY INTERFACES AND RELAYS
SAFETY INTERFACES SAFETY INTERFACES AND RELAYS AD SR1 TYPE 4 INTERFACE FOR LIGHT CURTAINS Interface module between the safety light curtains EOS4 A, EOS2 A, Admiral AD, Admiral AX BK, Vision V with self-testing
More informationInsulation fault evaluator EDS460-DG
Insulation fault evaluator for localising insulation faults in DC IT systems with a number of branch circuits where high system leakage capacitances are involved Preliminary data sheet TDB108021en/09.2008
More informationEngineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC
Engineering Guideline pac-carriers Type 9195 for TRICON system TRICONEX TMR PLC 2 Engineering Guideline TRICON system 14.10.2009 Content Signal type Control system I/O cards type pac-carrier Channels Slots
More informationSmartAlarm Annunciator
Annunciator Specification/Features The Annunciator offers a modern compact DIN package that includes state of the art critical alarm capture in an industry standard footprint 1. High Intensity LED s 2.
More informationISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)
ISOSCAN EDS460/490 EDS461/491 Insulation fault locators with control and display function for EDS systems (insulation fault location systems) EDS460-490_D00085_01_D_XXEN/01.2017 ISOSCAN EDS460/490 EDS461/491
More informationOperating instructions Safety-monitoring module SRB 302X3. 1 About this document
1 About this document Operating instructions... pages 1 to 6 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information you need for
More informationResidual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)
Residual current monitor RCM470LY/RCM475LY for TN and TT systems (AC and pulsating DC currents) TDB401003en/03.2010 Residual current monitor RCM470LY Residual current monitor for TN and TT systems (AC
More informationPanel Mounted Fault Annunciator Series
Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with,,,, 0 and signal inputs Storage of the last state of inputs and sequence in the case
More informationSafety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device
Safety Instructions Used symbols Important Comments Before starting with installation of the MS 10B Alarm Unit, we recommend you to read the important information beneath. Qualification The installation
More informationSensaGuard TM Integrated Latch Installation Instructions
TM Integrated Latch Installation Instructions Certifications IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE Note: Refer to Technical Specifications for Certification information and ratings. 2 TM Installation
More informationRFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.
RFID Non-contact Safety Switches RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance. Based on RFID technology,
More informationGas Controller Module GC-06
Page 1 Oct. 2015/2 Measuring, warning and controlling module for toxic, combustible and refrigerant gases and vapours. The gas controller series GC-06 is designed in accordance with the standard EN 50545-1.
More informationDUAL MONITORED INPUT/OUTPUT UNIT BN-305-2
DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection
More informationGeneral terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.
897 Safety Sensor SERIES Related Information General terms and conditions... F-7 General precautions... P.1501 Sensor selection guide... P.885~ Korea s S-mark... P.1506 PHOTO PHOTO Conforming to Machinery
More informationPROTECT SRB 200EXi-1A
2 Installation up to zone 1/21 J S L1 0V X1 X3 S11 S12 S21 S22 Installation up to zone 2 A1 F1 F2 U B U EXi U i 0V S12 S22 X1 X3 K1 Logic K2 K1 K2 13 23 U EXi SRB 200EXi U B -1A U i K1 K2 PA PA A1 A2 13
More informationRTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals
Technical Information RTA421 Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals Application Plant and machine construction Panel builders Process monitoring Process
More informationDTA04. Motor thermistor relay. Benefits. Description
Motor thermistor relay Benefits High operating safety. The thresholds are determined by the Motor PTC. Beyond the specified temperature the output stops the motor/s. Save time and costs.there is no need
More informationPolyGard 2-channel Gas Controller MGC-03
PolyGard 2-channel Gas Controller MGC-03 DESCRIPTION Gas measuring and monitoring controller based on state-ofthe-art micro-technology with integrated buzzer for continuous monitoring of the ambient air
More informationOMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments
OMC-158-2 Ex interface unit Manual Version 1.2 August 2017 Author: Observator Instruments Revisions: 0.1 (October 2016) First issue 0.2 (December 2016) Prototype 0.3 (January 2017) Test release 1.0 (March
More informationOriginal operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...
Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...12 m OY UK 704555 / 05 02 / 2018 Contents 1 Preliminary note...4
More informationSonos-SB Siren/Beacon
Sonos-SB Siren/Beacon Audible/optical signal transmitter compliant with EN 54-3 and EN 54-23 for fire alarm systems, in red and white. Wall mounting (category W) and ceiling mounting (category C) for indoor
More informationTOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design
TOTAL SOLUTIONS Liquid Level Control Product Guide MATELEC innovative by design Liquid Level Control Contents Dual Pump Controllers Section 1 The Range Common Features Operating Data Control Logic Setup
More information1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER
Application The unit is primarily intended for use where there is a requirement to integrate a limited fire protection function into a larger control equipment scheme, or in specialist applications where
More informationInterface and EOL Modules 8
Interface and EOL Modules Interface Modules Series 420 25 Interface Modules Series 100 291 EOL Modules 293 254 Interface and EOL Modules Interface Modules Series 420 Interface Modules Serie 420 Interface
More informationPHOTOELECTRIC AMPLIFIER SERIES
PHOTOELECTRIC AMPLIFIER SERIES Telco s photoelectric amplifier series performs as good today as it did when it first appeared almost 25 years ago. But while the simple design of this iconic product has
More informationMSM - Expansion modules
MSM - Expansion modules Transistor- and relay modules for devices of the MSM-product family Free assignment of the output arrays to the input arrays of the annunciator Triggering of relays or transistor
More informationNGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW
NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The nvent RAYCHEM NGC-40 is a multipoint
More informationOperating Manual MS220DA
ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße 13, D 74523 Schwäbisch Hall + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panel Meters MINIPAN
More informationSensing light curtain as per DIN 18650/EN 16005
TÜV NORD CERT B GmbH Sensing light curtain as per DIN 8650/EN 6005 -DS-P-00/30 Dimensions 38 L 4 aumuster geprüftf Zertifiziert nach DIN 8650 In accordance with Model Number -DS-P-00/30 Active infrared
More informationOn the job around the clock 24/7: Fire detection systems
On the job around the clock 24/7: Fire detection systems Version 02.2010 Version: 02.2010 Product catalogue Fire detection systems This product catalogue is intended for sales purposes only. For planning,
More informationLights up when conditions are normal (and at incipient liquid leak detection) Use as a warning. Sensor. Ensure productivity. Emergency stop.
843 Safety Liquid Leak Sensor SQ4 SERIES FIBER PHOTO MICRO PHOTO AREA LIGHT CURTAINS Related Information General terms and conditions... F-17 General precautions... P.1405 Sensor selection guide... P.831~
More informationNGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3
NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic
More information4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en
Technical information TI074R/09/en 51001353 Contactor RTA421 Contactor with loop power supply for monitoring currentorvoltagesignals Application areas Plant and machine construction Panel builders Process
More informationBasics of Safety Applications
Basics of Safety Applications Unrestricted Siemens 2016 usa.siemens.com/controls Why Safety Technology? Protection of People Environment Page 2 Safety Process Chain The necessary steps towards a safe machine
More informationpanasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor
867 Safety Sensor SERIES Related Information General terms and conditions... F-3 General precautions... P.1595 guide... P.865~ Korea s S-mark... P.1602 PHOTO PHOTO Certified by NRTL Conforming to SEMI-S2
More informationDPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description
DPB52 True RMS 3-Phase, Multifunction monitoring relay Description Benefits Measuring Voltage Range. Very wide input voltage range: from 125 to 624V ( 208V 40% to 480 + 30% ). Adjustable Voltage Ranges
More informationEngineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules
Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015 pac-carrier Type 9195 Integration of conventional
More informationisopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)
T M 1 isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012372 / 03.2015 isopv
More informationBasics of Safety Applications
Basics of Safety Applications Unrestricted Siemens 2016 usa.siemens.com/controls DISCLAIMER/ TERMS OF USE: THE INFORMATION PROVIDED HEREIN IS PROVIDED AS A GENERAL REFERENCE REGARDING THE USE OF THE APPLICABLE
More informationRetroreflective sensor with polarization filter
Dimensions 45 49 Receiver 23 27 74 56 Emitter 92 23 6 x 9 slots External thread (M30 x 1.5) 10 25 32 M12 x 1 Sens Delay IMER Model Number Retroreflective sensor with 4-pin, M12 x 1 connector Electrical
More informationISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)
Insulation monitoring device for unearthed AC/DC control circuits (IT systems) TDB103005en/05.2013 Insulation monitoring device for unearthed AC/DC control circuits (IT systems) Product description The
More informationLINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage
LINETRAXX VME420 Multi-functional monitoring relay for undervoltage, overvoltage and frequency monitoring in AC/DC systems with separate supply voltage VME420_D00026_01_D_XXEN/06.2016 LINETRAXX VME420
More informationSensing light curtain as per DIN 18650/EN 16005
TÜV NORD CERT B GmbH Dimensions 38 L 4 aumuster geprüftf Zertifiziert nach DIN 8650 In accordance with Model Number Active infrared scanner Profile length 00 mm Electrical connection Features BN 4V Moving
More informationGESTRA Steam Systems NRS English. Installation Instructions Level Switch NRS 1-51
GESTRA Steam Systems NRS 1-51 EN English Installation Instructions 818955-04 Level Switch NRS 1-51 1 Contents Application Page Usage for the intended purpose...4 Function...4 Directives and Standards Pressure
More information1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 505 Grünberg Tel.: 060 807-0 Fax: 060 807-59 A-ISOMETER IRDH575 Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with
More informationGMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions
Worldwide upplier of Gas Detection olutions GfG Instrumentation 1194 Oak Valley Drive, uite 20 Ann Arbor, MI 48108 800-959-0329 tel 734-769-1888 fax email: info@gfg-inc.com GMA4100-DP Control Panel Operation
More informationISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)
Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) IRDH375_D00124_01_D_XXEN/07.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Product
More informationParameterisable compact fault annunciator with permanent display
Parameterisable compact fault annunciator with permanent display FSM 10 Drop-flap fault annunciator 31.08.2010 Permanent display even on power failure Compact module for 10 alarms Supply and alarm signal
More informationISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances
ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances _D00108_00_D_XXEN/05.2015 ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances
More informationGRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions
GRUNDFOS INSTRUCTIONS LCD 08 Installation and operating instructions Installation and operating instructions Original installation and operating instructions CONTENTS Page. Symbols used in this document.
More informationFire control panel detect 3004 plus and accessories
Fire control panel detect 3004 and accessories The modular fire alarm panel detect 3004 is the basic version of a broad product portfolio of the system detect 3000. Up to 20 fire control panels can be
More informationBS-316. Gas detection control panel up to 16 inputs. Installation operation manual
BS-316 Gas detection control panel up to 16 inputs Installation operation manual Page 1 from 21 Contents 1 Operation instructions--------------------------------------------------------------------------------------------------------------------3
More informationPolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours
PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor
More informationIT system floor-standing distribution
IT system floor-standing distribution cabinet series -IPS-F/EDS for supplying power to medical locations in accordance with IEC 60364-7-710 and featuring a built-in insulation fault location system IT
More informationControl and Annunciator Panels. Compact systems of signalling and control
Control and Annunciator Panels Compact systems of signalling and control 56 Control and Annunciator Panels Technical features Body material: Polycarbonate V0/UL 9 - Colour: Black degree: IP0 Not replaceable
More informationOperating Instructions. For. Alarm Control Module. Model SSR 500
SSR 500 LEVEL CONTROL RELAY MODULE Operating Instructions For Alarm Control Module Model SSR 500 SSR Operation Instructions Rev. 1 Jan 01 Page 1/7 1. Note Please read and take note of these operating instructions
More informationHeat Sensor Cable Alarm Units DT650L / DT950L
Heat Sensor Cable Alarm Units DT650L / DT950L For conventional and 950 series analogue addressable systems Installation and Commissioning Manual Version 2.1 / May 2004 http://www.geindustrial.com/ge-interlogix/emea
More informationThroughbeam photoelectric sensor for the detection of aqueous liquids. Dimensioned drawing
Technical data and description LS 55 Throughbeam photoelectric sensor for the detection of aqueous liquids Dimensioned drawing en 03-2016/11 50127872-02 350 Hz 0 80m 10-30 V DC We reserve the right to
More informationProcess Alarm Module RTA 421
Technical Information TI 074R/24/ae Process Alarm Module RTA 421 Alarm module and power supply for monitoring current or voltage signals Application Areas Plant and machine construction Panel builders
More informationImproved productivity Two-stage detection
Control Category 4 PLe SIL3 SAFETY LIQUID LEAK SENSOR SQ4 SERIES Conforming to Machinery & EMC Directive Certified Certified Certified by NRTL Conforming to SEMI-S2 Industry first* Improved productivity
More informationECO N DATE DESCRIPTION OF CHANGE CHG
Model Number: M21E-24-DIN Description: The product is a loop powered device which controls an unsupervised dual pole output channel suitable to manage 24VAC loads. The M21E-24-DIN is micro-controller operated,
More informationGeneral Specifications
General Specifications GS J0H-0E Model MVHK Digital Limit Alarm (DC Type) with Active Color PV Display General This plug-in type Digital Limit Alarm for DC input receives DC current or DC voltage signal.
More informationSBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)
SBEx-4 BISTATE SEPARATOR,, 3 or 4 channels in rail housing (TS3,,mm width) - group I category (M), group II and III category () accompanying device, - intrinsically safe input circuits with ia protection
More informationACS-30-EU-EMDR- 10-MOD
ACS-30-EU-EMDR- 10-MOD MULTI-APPLICATION HEAT TRACING CONTROL AND MONITORING IN COMMERCIAL AND RESIDENTIAL BUILDINGS ROOF & GUTTER DE-ICING SENSOR MODULE TECHNICAL INFORMATION DESCRIPTION The nvent RAYCHEM
More informationResistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection
7 0 Selection guide TO CONTROL THE TEMPERATURE Respects the entered value Compact fixed thermostats Preset factory temperature: NA (blue button):, 0, ºC for the resistance heater. (red button):, 0, ºC
More informationPanel Mounted Fault Annunciator Series
Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with 8, 16, 24, 32, 40 and 48 signal inputs Status retention of inputs and sequence in case
More informationBulletin 440N-Z 440N-S 440K 440G. Sipha Magnetically Coded Non Contact Switches
Bulletin 440N-S, 440N-Z, 440K, 440G Product Line Overview Safety Interlock (440N-S, 440N-Z, 440K, 440G) 6 / 2011 Bulletin 440N-Z 440N-S 440K 440G Type Standards Product Selection SensaGuard RF-ID Coded
More informationISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15
with coupling device AGH675-7 and AGH675-7MV15 Device combination for insulation monitoring in unearthed AC, AC/DC and DC power systems (IT systems) IRDH275BM-7_D00123_03_D_XXEN/01.2017 with coupling device
More informationDTA. Motor thermistor relay. Benefits. Description
DTA Motor thermistor relay Description DTA71 and are precise Motor thermistor monitoring relays. They can monitor up to 6 motor temperatures through the motor internal temperature. PTCs are connected in
More informationUltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW
12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes
More informationModel 4880 Status Output Display Module Manual
Model 4880 Status Output Display Module Manual 1-2 150912 Section 1 Introduction The 4880 provides 16 switched outputs, 4 form C relay contacts, and an X10 module interface. See Table 2-1 for electrical
More informationHands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018
Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018 Before we start A Penny for Your Thoughts At the end of the session, share your feedback via
More informationISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V
Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V IR1575_D00116_00_D_XXEN/05.2015 Insulation monitoring device for unearthed AC/3(N)AC systems up to 480
More informationConnections, displays and operating elements C D E G H. Installing the control unit
1 2 3 GB Control unit 0-10 V REG-K/3-gang with manual mode Operating instructions Art. no. MTN646991 ¼ DANGER Risk of fatal injury from electrical current. All work on the device should only be carried
More informationFire / CO Alarm Interface
Fire / CO Alarm Interface Model: Ei414 Instruction Manual Read and retain carefully for as long as the product is being used. It contains vital information on the operation and installation of your Fire
More informationMulti-Gas-Controller MGC2
Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants
More informationEmergency power automatics MS-2. High resistance to shock, vibrations and transients. All output are 2A relay contacts
Emergency power automatics Type EPOMATIC MS-2, EC-2 4921240002D MS-2 EC-2 DEIF A/S All necessary functions: - mains supervision - start/supervision/stop of diesel engine - control of circuit breakers and
More informationDUAL MONITORED INPUT/OUTPUT UNIT BN-305
DUAL MONITORED INPUT/OUTPUT UNIT BN-30 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection
More informationPolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen
PolyGard Single Point Controller SPC-X3-XX for Toxic Gases and Oxygen DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor and
More informationIntesisBox BACnet/IP Server - Notifier ID3000 series
IntesisBox Server - Notifier ID3000 series Gateway for integration of Notifier ID3000, ID3002, ID50 and ID60 fire panels into enabled control systems. Integrate your Notifier fire panels into your BACnet
More informationDOCUMENTATION IPS640
DOCUMENTATION IPS640 TECHNICAL AND APPLICATION DESCRIPTION Authors: Nebojša Božič, Peter Hauner Last modification: 2017-01-25 2001-2017 Apricum d.o.o. Mažuranićeva 4, 21312 Podstrana, Hrvatska Details,
More informationDOCUMENTATION IPS640
DOCUMENTATION IPS640 TECHNICAL AND APPLICATION DESCRIPTION Authors: Nebojša Božič, Peter Hauner Last modification: 2018-07-06 2001-2018 Apricum d.o.o. Mažuranićeva 4, 21312 Podstrana, Hrvatska Details,
More information