EXNBG CLARIFICATION/DECISION SHEETS NOTED BY THE ATEX STANDING COMMITTEE STATUS ON DECEMBER 2009

Size: px
Start display at page:

Download "EXNBG CLARIFICATION/DECISION SHEETS NOTED BY THE ATEX STANDING COMMITTEE STATUS ON DECEMBER 2009"

Transcription

1 EXNBG CLARIFICATION/DECISION SHEETS NOTED BY THE ATEX STANDING COMMITTEE STATUS ON DECEMBER 2009 Number ExNB/CS/ DS (1) Edition Subject / Keywords 98/06/ Certification of a torch according to EN 50020:1977 clauses 9 and or EN 50020:1994 clauses 10 and /06/ Conformity to type Notification Format (ATEX Directive Annex VI) 98/06/ EN 50019: Internal contacts on zoned heating tapes 98/06/ Minimum requirement for thread engagement/npt cable entry holes in flameproof apparatus to EN /06/ EN 50020:1977 sub-clause 7.2 and EN 50020:1994 sub-clause Voltage source of EEPROMs etc. 99/06/ EN 50020:1977 sub-clause 7.2 and EN 50020:1994 sub-clause "EEX ib" 99/06/ EN 50020:1977 and EN 50020: Marking of apparatus with alternative protection "d" or "i" 99/06/ EN 50020:1977 and EN 50020:1994 sub-clause Calculation of multiple separation distances 99/06/ EN 50020:1977 sub-clause 5.5 and EN 50020:1994 sub-clause Separation for insulated components Approved by ExNBG (2) Authorized / Issued Noted by ATEX SC (3) 17/06/98 07/08/98 01/12/05 17/06/98 07/08/98 01/12/05 17/06/98 07/08/98 01/12/05 17/06/98 07/08/98 01/12/05 16/06/99 10/02/00 29/06/01 16/06/99 10/02/00 29/06/01 16/06/99 10/02/00 29/06/01 16/06/99 10/02/00 29/06/01 16/06/99 10/02/00 29/06/01 00/06/ EC-Type Examination for Category 3 products 29/09/00 03/11/00 27/11/09 00/06/ Recommendations on the measurement of the maximum temperature of light transmitting parts of products intended for use in potentially explosive atmospheres using thermocouples 30/06/00 03/11/00 08/12/00 00/06/ EN 50020:1994, clause 6.5 "Protection against 30/06/00 03/11/00 08/12/00 polarity reversal" 00/06/ Short temperature rise of Ex p motors during 30/06/00 03/11/00 08/12/00 starting 00/06/ Change of the standard wording of Article 11 of the 30/06/00 03/11/00 01/12/05 EC-Type Examination Certificate 00/ EN 50014:1977 Clause 7 and EN 50014: /03/04 01/12/05 clause 8, light alloys in Group I apparatus 00/ EN 50018:1977 Clause and EN 50018: /03/04 01/12/05 Clause 5.2.3, rectangular spigot joints 00/ EN 50028:1987 Clause 4.1.2, internal voids 09/03/04 01/12/05 00/ Procedural - Ex-components, indication of the 09/03/04 01/12/05 temperature class in the marking 00/ Certificate of Conformity of a flameproof enclosure 09/03/04 27/11/09 containing different components 00/ EN 50014:1977 Clause 13 and EN 50014: /03/04 01/12/05 Clause 15, earthing of traction batteries 00/ Procedural - Group I component certificates marked with the epsilon-x in the same way as Group II 27/11/09 00/ EN 50018:1977 Clause 14 and EN 50018:1994 Clause 15, heating cables 00/ EN 50019:1977 Clause and EN 50019:1994 Clauses & , materials used inside battery containers 00/ EN 50018:1977 Clause 6 and EN 50018:1994 Clause 7, wear-push rods and spindles in flameproof enclosures 09/03/04 01/12/05 09/03/04 01/12/05 09/03/04 01/12/05 European Commission Page 1 of 4 December 2009

2 Number ExNB/CS/ DS (1) Edition Subject / Keywords 00/ EN 50018:1977 Clause 12.1 and EN 50018:1994 Annex C, cable entry seal under tension 00/ EN 50018:1977 Clause 3 and EN 50018:1994 Clause 4, T Class for EEx d motors 00/ EN 50014:1977 Clause 7 and EN 50014: 1994 Clause 8, light alloys 00/ EN 50018:1977 Clause 10 and EN 50018:1994 Clause 11, non ISO threads 00/ EN 50014:1992 Clause 13, interchangeablity of Group I and Group II components 00/ EN 50019:1977, ventilation and IPX3 testing of batteries 00/ EN 50019:1977, dielectric strength tests for junction boxes 00/ EN 50014:1977 Clause 6.3 and EN 50014:1992 Clause 7.3.2, electrostatic hazard 00/ EN 50014:1977 Clause 16 and EN 50014:1992 Clause 17, fans 00/ Cables ends or cables between parts of apparatus for types of protection other than intrinsic safety 00/ EN 50018:1977 Clause 3 and EN 50018:1994 Clause 14, frequency converters and EEx d motors 00/02/ Temperature rise tests, flameproof motors, frequency converters, thermal protection, general methodology 99/11/ Plastic parts, on which the safety of type of protection "Flameproof Enclosure" depends Approved by ExNBG (2) Authorized / Issued Noted by ATEX SC (3) 09/03/04 01/12/05 09/03/04 01/12/05 09/03/04 01/12/05 09/03/04 01/12/05 09/03/04 01/12/05 09/03/04 01/12/05 09/03/04 01/12/05 09/03/04 01/12/05 09/03/04 01/12/05 09/03/04 01/12/05 09/03/04 01/12/05 21/02/00 10/02/00 29/06/01 10/11/99 10/02/00 29/06/01 99/06/ EN Flexible walls, flameproof enclosures 16/06/99 10/02/00 29/06/01 98/ Test for cells and batteries; EN 50020:1994; /06/01 06/02 01/12/05 98/ EN 50020: Rating of components related to associated apparatus with galvanic isolation. Reference HOTL (95)CESI/001 08/06/00 06/01 01/12/05 98/ EN 50020:1994 sub-clause and /09/02 01/12/05 rev. 1 Verification of CTI for 'i' 99/06/ EN 50018: Gas analysis performed within a 16/06/99 10/02/00 29/06/01 flameproof enclosure 99/01/ Outcome of the assessment (Clause 3.3 of Annex 15/04/99 28/05/99 01/12/05 IV and Annex VII) 99/11/ Impact test of non metallic enclosures (or 10/11/99 10/02/00 29/06/01 enclosure parts) 99/11/ Marking of associated apparatus according to EN 10/11/99 10/02/00 29/06/ /080 Proposal to modify the standard wording on EC- 08/06/00 27/11/09 Type Examination Certificates 99/ Instructions and EC-type examination 30/06/00 03/11/00 01/12/05 99/ Apparatus with a measuring function for explosion protection where a part is situated in an explosive atmosphere 09/06/00 06/01 01/12/05 99/ Handling and storage of the dossier for nonelectrical equipment category M2 and 2 according to Annex VIII, paragraph 3 00/ Flame arresters (autonomous protective systems), assessment of test results obtained under instable detonation conditions 00/ Structure of and requirements for EC-Type Examination Certificates of flame arresters 01/ Ex e temperature rise test according to EN and EN standards concerning electrical motors 08/06/00 06/01 01/12/05 15/06/01 14/12/01 01/12/05 15/06/01 14/12/01 01/12/05 15/01/01 06/02 01/12/05 European Commission Page 2 of 4 December 2009

3 Number ExNB/CS/ DS (1) Edition Subject / Keywords 01/ EC-type examination of gas detectors incorporating a measuring function for explosion protection 01/ EC-type examination of gas detectors incorporating a measuring function for explosion protection 01/ Guidelines on the management of assessment and surveillance programmes for products covered by Annex IV and VII of the ATEX Directive 94/9/EC 02/ Requirements and test procedure for heating equipment of explosion venting devices 02/ Equipment with connections between areas covered by directive 94/9/EC and areas with high pressure 02/ EC-type examination of gas detectors incorporating a measuring function for explosion protection 02/ EC-type examination and supervision of production for gas detectors incorporating a measuring function for explosion protection 02/ Distribution, availability and definition of the "Relevant information" to be "communicated" to other notified bodies following issue or withdrawal of EC-type Examination Certificates, Production QA Notification Certificates and Product QA Notification Certificates Approved by ExNBG (2) Authorized / Issued Noted by ATEX SC (3) 15/01/01 14/10/01 01/12/05 15/01/01 14/12/01 01/12/05 15/01/01 14/12/01 01/12/05 10/09/02 07/03/03 27/03/02 18/06/03 27/11/09 18/06/03 27/11/09 18/06/03 27/11/09 18/06/03 27/11/09 00/ EN 50019:1977 Ex "e" rated voltage windings 09/03/04 01/12/05 00/ EN 50020:1977 and EN 50020: T-class for 09/03/04 01/12/05 small coils 00/ EN 50028:1987 Clause 6.2.1, rated voltage and 09/03/04 01/12/05 external fault conditions 00/ EN 50014:1977 Clause and EN 50014: /03/04 01/12/05 Clause , guards for light transmitting parts 00/ EN 50018:1977 Clause 8 and EN 50018:1994 Clause 9, glass windows directly fused into the metallic housing 09/03/04 01/12/05 00/ EN 50019:1977, trace heating tapes 09/03/04 01/12/05 00/ EN 50028:1987 Clause Permitted 09/03/04 01/12/05 Prospective Short Circuit Current 03/ Equipment with a measuring function for explosion protection, drop test for remote sensors of fixed apparatus 09/03/04 01/12/05 03/ Equipment with a measuring function for explosion protection, high gas concentrations above the measuring range 03/ Equipment with a measuring function for explosion protection, battery capacity 03/ Equipment with a measuring function for explosion protection, examination of catalytic sensors of portable multigas apparatus 09/03/04 01/12/05 26/11/04 24/05/05 01/12/05 09/03/04 01/12/05 04/160 Radio frequency power limitation 26/11/04 24/05/05 01/12/05 04/161 Instructions for high volume, low value equipment 25/11/04 24/05/05 27/11/09 04/170 Control units for gas warning equipment 26/11/04 24/05/05 01/12/05 05/190 Fluorescent lamps in Ex-luminaires 26/11/04 24/05/05 01/12/05 07/264 Content of technical documentation 28/11/06 30/07/07 27/11/09 07/265 Scope of EN in addressing Annex IV and 28/11/06 30/07/07 27/11/09 VII 07/266 Application of the latest technical knowledge 28/11/06 30/07/07 27/11/09 07/267 Structure of and requirements for EC-Type 28/11/06 30/07/07 27/11/09 European Commission Page 3 of 4 December 2009

4 Number ExNB/CS/ DS (1) Edition Subject / Keywords Approved by ExNBG (2) Authorized / Issued Noted by ATEX SC (3) Examination Certificates for flame arresters 07/268 Proposal for amendment to Annex of EN /02/07 30/07/07 27/11/09 07/269 Proposal for amendment to Annex of EN /02/07 30/07/07 27/11/09 07/282 Ex q faults and overloads 20/10/08 27/11/09 07/283 IP Testing of Enclosures with non-metallic parts 20/10/08 27/11/09 (gaskets) 09/338 Instructions and year of manufacture 28/11/08 28/02/09 27/11/09 (1) : ExNB / xx.xx.xxx / CS/DS = European ATEX Notified Bodies / Numbering of the Clarification/Decision Sheet / CS/DS (2) : ExNBG = European ATEX Notified Bodies Group (3) : ATEX SC = ATEX Directive 94/9/EC Standing Committee European Commission Page 4 of 4 December 2009

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Page 1 of 1 European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/00/29/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL Date: Step*5.2.3 Initial proposal Proposer: Date: Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Subject: EN 50014:1977 clause 7 and EN 50014:1992 Clause 8, Light Alloys in Group I Apparatus Authorised by Chairman: M. Shearman Date: Date of application: Signature: M D Shearman Question: Can portable apparatus, with enclosures of light alloy be certified for Group I? Answer: Yes, provided a tight fitted or secured leather case is used. 1 Current wording relates to 76/117/EEC, may be superseded This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. G:\ARCHIV\EG-Sekretariate\Explosionsschutz\Allgemeines\Entzippt\ExNB00-29CS.DOC

28 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Page 1 of 1 European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/00/031/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL Date: Step*5.2.3 Initial proposal Proposer: Date: Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Subject: EN 50018:1977 Clause and EN 50018:1994 Clause 5.2.3, Rectangular Spigot Joints Authorised by Chairman: M. Shearman Date: Date of application: Signature: M D Shearman Question: Answer: Are spigot joints with a rectangular shape/section, (with or without rounded corners), consisting of a flat part and a spigot part permitted without restrictions? Yes. These are permitted without restriction provided that the minimum values of width of joint and of maximum gap indicated in tables 3 and 4 of EN 50018:1977 or in tables 1 and 2 of EN 50018:1994 are observed. However, when there is no flat part of the spigot joint acetylene is excluded from Group IIC. 1 Current wording relates to 76/117/EEC, may be superseded This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. G:\ARCHIV\EG-Sekretariate\Explosionsschutz\Allgemeines\Entzippt\ExNB00-31CS.DOC

29 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Page 1 of 1 European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/00/033/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL Date: Step*5.2.3 Initial proposal Proposer: Date: Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Subject: EN 50028:1987 Clause Internal Voids Authorised by Chairman: M. Shearman Date: Date of application: Signature: M D Shearman Question: Answer: Clause of EN permits internal voids up to 100cm 3. Is it permitted to include larger components where the enclosed space is filled with loose inert material, for example glass beads, in order to reduce the free volume below 100cm 3? No 1 Current wording relates to 76/117/EEC, may be superseded This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. G:\ARCHIV\EG-Sekretariate\Explosionsschutz\Allgemeines\Entzippt\ExNB00-33CS.DOC

30 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Page 1 of 1 European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/00/034/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL Date: Step*5.2.3 Initial proposal Proposer: Date: Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Subject: Procedural Authorised by Chairman: M. Shearman Date: Date of application: Signature: M D Shearman Question: Answer: Are Ex-components to be certified without any indication of the temperature class in the marking? Yes, additional data such as power dissipation before a temperature class is reached may, however, be included in the test certificate if it is an aid to draw up a certificate of conformity. 1 Current wording relates to 76/117/EEC, may be superseded This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. G:\ARCHIV\EG-Sekretariate\Explosionsschutz\Allgemeines\Entzippt\ExNB00-34CS.DOC

31 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Page 1 of 1 European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/00/035/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL Date: Step*5.2.3 Initial proposal Proposer: HOTL Date: Step*5.2.4 Responses/Final Draft HOTL Date: *Step refers to ExNB Rules Subject: Certificate of Conformity of a Flameproof Enclosure Containing Different Components Authorised by Chairman: M. Shearman Date of application: Date: Signature: Question: Answer: What requirements need to be applied to certificates of conformity for Ex d enclosures, which can have different components built into them? The criteria for certificates of Conformity for d enclosures with different components to be built in, is as follows: a) A certificate should be issued for each specific apparatus (for example a measuring instrument, junction box or control unit); b) The electrical characteristics of the apparatus should be specified; c) The documents mentioned on the certificate should include a list of components mounted in the enclosure and a schematic representation of their layout; d) Installation of intrinsically safe circuits in enclosures should be restricted to special cases indicated in documents. This should also apply to capacitors and hot surfaces 1 Current wording relates to 76/117/EEC, may be superseded This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. G:\ARCHIV\EG-Sekretariate\Explosionsschutz\Allgemeines\Entzippt\ExNB00-35CS.DOC

32 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Page 1 of 1 European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/00/037/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL Date: Step*5.2.3 Initial proposal Proposer: Date: Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Subject: EN 50014:1977 Clause 13 and EN 50014:1992 Clause 15 Earthing of Traction Batteries Authorised by Chairman: M. Shearman Date: Date of application: Signature: M D Shearman Question: Can a certificate of conformity be issued for a traction battery without an internal and/or external earth, being in proper electrical contact with the chassis by installation requirements? Answer: Yes 1 Current wording relates to 76/117/EEC, may be superseded This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. G:\ARCHIV\EG-Sekretariate\Explosionsschutz\Allgemeines\Entzippt\ExNB00-37CS.DOC

33 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Page 1 of 1 European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/00/38/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL Date: Step*5.2.3 Initial proposal Proposer: Date: Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Subject: Directive, 94/9/EC Article No. Directive, ESR No. Directive, Module Annex No. Standard, No. Authorised by Chairman: M. Shearman Date of application: Date: Signature: Subject: Procedural Question: Can Group I component certificates be marked with the epsilon-x in the same way as Group II? Answer: Yes 1 May be superseded by CS of ExNB This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. U:\Common\09 ATEX\06 Notified Bodies\clarification sheets\valid_clarification_sheets\exnb00-038cs.doc

34 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Page 1 of 1 European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/00/039/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL Date: Step*5.2.3 Initial proposal Proposer: Date: Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Subject: EN 50018:1977 Clause 14 and EN 50018:1994 Clause 15, Heating Cables Authorised by Chairman: M. Shearman Date: Date of application: Signature: M D Shearman Question: Answer: Are bending tests required for heating cables complying with the Flameproof design according to the standard EN and of which the enclosure consists of a flexible sheath and is earth fault protection required? Yes, they shall be submitted to the bending tests foreseen by amendment 4 of the standard EN Also an earth fault shall be foreseen and so an electrical protection device in relation to an earth fault is required. 1 Current wording relates to 76/117/EEC, may be superseded This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. G:\ARCHIV\EG-Sekretariate\Explosionsschutz\Allgemeines\Entzippt\ExNB00-39CS.DOC

35 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Page 1 of 1 European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/00/041/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL Date: Step*5.2.3 Initial proposal Proposer: Date: Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Subject: EN 50019:1977 Clause and EN 50019:1994 Clauses & Materials used inside Battery Containers Authorised by Chairman: M. Shearman Date: Date of application: Signature: M D Shearman Question: Answer: For materials used in the construction of a battery, what procedure should be used to determine that the requirements of clause of EN are fulfilled? 1) The manufacturer sends to the testing station a declaration, dated and signed to attest that the requirements of clause of EN are fulfilled. 2) In case of doubt the testing station may carry out the control. Note Clarification still necessary according to ExNB WG 97/4 1 Current wording relates to 76/117/EEC, may be superseded This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. G:\ARCHIV\EG-Sekretariate\Explosionsschutz\Allgemeines\Entzippt\ExNB00-41CS.DOC

36 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Page 1 of 1 European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/00/042/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL Date: Step*5.2.3 Initial proposal Proposer: Date: Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Subject: EN 50018:1977 Clause 6 and EN 50018:1994 Clause 7, Wear -Push Rods and Spindles in Flameproof Enclosures Authorised by Chairman: M. Shearman Date: Date of application: Signature: M D Shearman Question: Answer: What criteria is to be used, to determine if the wear experienced by a push rod or spindle will be sufficient to affect the Flameproof properties of a joint and consequently whether or not bearings are required? This is a matter of engineering judgement but where doubt exists, life testing of the assembly followed by transmission testing under the most adverse conditions will be undertaken. 1 Current wording relates to 76/117/EEC, may be superseded This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. G:\ARCHIV\EG-Sekretariate\Explosionsschutz\Allgemeines\Entzippt\ExNB00-42CS.DOC

37 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Page 1 of 1 European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/00/045/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL Date: Step*5.2.3 Initial proposal Proposer: Date: Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Subject: EN 50018:1977 Clause 12.1 and EN 50018:1994 Annex C, Cable Entry Seal Under Tension Authorised by Chairman: M. Shearman Date: Date of application: Signature: M D Shearman Question: Answer: Can a cable entry be certified in which the seal operates under tension rather than under compression? Yes, the cable entry can be dealt with as a part of a plastic enclosure and can be certified if the component withstands all tests specified for plastic enclosures. 1 Current wording relates to 76/117/EEC, may be superseded This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. G:\ARCHIV\EG-Sekretariate\Explosionsschutz\Allgemeines\Entzippt\ExNB00-45CS.DOC

38 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Page 1 of 1 European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/00/046/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL Date: Step*5.2.3 Initial proposal Proposer: Date: Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Subject: EN 50018:1977 Clause 3 and EN 50018:1994 Clause 4 T Class for EEx d Motors Authorised by Chairman: M. Shearman Date: Date of application: Signature: M D Shearman Question: Answer: With respect to the determination of temperature class of flameproof motors, is the use of thermal switches generally accepted to limit the temperature within the required values and is this always sufficient? The use of thermal switches is generally accepted to limit the temperature within the required values. The thermal detectors in windings are not always sufficient to ensure the temperature limitation; in particular, in the case of inverter fed motors, temperature rises in bushings and bearings must be taken into account. 1 Current wording relates to 76/117/EEC, may be superseded This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. G:\ARCHIV\EG-Sekretariate\Explosionsschutz\Allgemeines\Entzippt\ExNB00-46CS.DOC

39 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Page 1 of 1 European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/00/047/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL Date: Step*5.2.3 Initial proposal Proposer: Date: Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Subject: EN 50014:1977 Clause 7 and EN 50014: 1994 Clause 8, Light Alloys Authorised by Chairman: M. Shearman Date: Date of application: Signature: M D Shearman Question: Answer: Does the relaxation of clause 8.3 of EN 50014:1992 refer to portable measuring instruments? Yes 1 Current wording relates to 76/117/EEC, may be superseded This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. G:\ARCHIV\EG-Sekretariate\Explosionsschutz\Allgemeines\Entzippt\ExNB00-47CS.DOC

40 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Page 1 of 1 European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/00/048/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL Date: Step*5.2.3 Initial proposal Proposer: Date: Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Subject: EN 50018:1977 Clause 10 and EN 50018:1994 Clause 11, Non ISO Threads Authorised by Chairman: M. Shearman Date: Date of application: Signature: M D Shearman Question: Answer: Are non-iso threads permitted to be used for special fasteners in flameproof enclosures? No Note Clarification still necessary according to ExNB WG 97/4 1 Current wording relates to 76/117/EEC, may be superseded This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. G:\ARCHIV\EG-Sekretariate\Explosionsschutz\Allgemeines\Entzippt\ExNB00-48CS.DOC

41 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Page 1 of 1 European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/00/049/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL Date: Step*5.2.3 Initial proposal Proposer: Date: Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Subject: EN 50014:1992 Clause 13 Interchangeablity of Group I and Group II Components Authorised by Chairman: M. Shearman Date: Date of application: Signature: M D Shearman Question: Answer: Are Group II certified components acceptable in Group I apparatus and viceversa? Yes, the respective Standard requirements are identical for both Groups Note Clarification still necessary according to ExNB WG 97/4 1 Current wording relates to 76/117/EEC, may be superseded This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. G:\ARCHIV\EG-Sekretariate\Explosionsschutz\Allgemeines\Entzippt\ExNB00-49CS.DOC

42 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Page 1 of 1 European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/00/051/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL Date: Step*5.2.3 Initial proposal Proposer: Date: Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Subject: EN 50019:1977 Ventilation and IPX3 Testing of Batteries Authorised by Chairman: M. Shearman Date: Date of application: Signature: M D Shearman Question: Are peak values of hydrogen concentration permitted, when testing the ventilation of batteries complying with EN 50019, Amendment 2. Also is an IPX3 test obligatory? Answer: Peak values of hydrogen concentration are permitted as long as the high concentration occurs for less than 30 minutes. A practical test of IPX3 is not obligatory; experience with similar constructions may be used. If a practical test is carried out and water enters the enclosure, the insulation resistance test as described in of EN 50019/A2 must be passed successfully, to show that the quantity of water is not harmful. Note Clarification still necessary according to ExNB WG 97/4 1 Current wording relates to 76/117/EEC, may be superseded This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. G:\ARCHIV\EG-Sekretariate\Explosionsschutz\Allgemeines\Entzippt\ExNB00-51CS.DOC

43 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Page 1 of 1 European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/00/052/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL Date: Step*5.2.3 Initial proposal Proposer: Date: Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Subject: EN 50019:1977, Dielectric Strength Tests for Junction Boxes. Authorised by Chairman: M. Shearman Date: Date of application: Signature: M D Shearman Question: Answer: For EExe junction boxes equipped by the manufacturer with approved components, should the routine dielectric strength test be carried out with the components wired and if so how should the test be carried out? Yes, the test shall be carried out according to the following standards: - industrial control equipment: EN measurement control and laboratory use: EN Note Clarification still necessary according to ExNB WG 97/4 1 Current wording relates to 76/117/EEC, may be superseded This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. G:\ARCHIV\EG-Sekretariate\Explosionsschutz\Allgemeines\Entzippt\ExNB00-52CS.DOC

44 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Page 1 of 1 European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/00/053/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL Date: Step*5.2.3 Initial proposal Proposer: Date: Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Subject: EN 50014:1977 Clause 6.3 and EN 50014:1992 Clause 7.3.2, Electrostatic Hazard. Authorised by Chairman: M. Shearman Date: Date of application: Signature: M D Shearman Question: Answer: Note: Is it permissible to mark with a warning label, (visible to the user), fixed enclosures or parts of enclosures of plastic material of any size, if the usage does not imply the hazard of electrostatic charge? Yes, but it is not appropriate to use a warning if: - There is a rapid airflow (e.g. air flow meters, fans air guides, equipment intended to be installed in a mine gallery subject to forced ventilation, etc.) - The surface is intended to be touched frequently in service (e.g. keyboards, switches, windows likely to be cleaned frequently, touch screens on Visual Display Units). The use of an electrostatically harmless (e.g. leather) additional case is acceptable with X-marking for hand held apparatus 1 Current wording relates to 76/117/EEC, may be superseded This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. G:\ARCHIV\EG-Sekretariate\Explosionsschutz\Allgemeines\Entzippt\ExNB00-53CS.DOC

45 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Page 1 of 1 European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/00/054/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL Date: Step*5.2.3 Initial proposal Proposer: Date: Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Subject: EN 50014:1977 clause 16 & EN 50014:1992 clause 17 - Fans Authorised by Chairman: M. Shearman Date: Date of application: Signature: M D Shearman Question: Answer: Do the requirements according to clause 16 of EN 50014:1977 (clause 17 of EN 50014:1992) apply for Group II fans for air-conditioning ('e' or 'd' motors with fan blades, hood etc) for a Certificate of Conformity? Yes they do. For fans intended to be mounted in ventilation duct systems the requirements for IP-protection and associated requirements for the parts providing the IP-protection (e.g impact test, light alloy enclosures) can also be fulfilled at the inlet and outlet of the duct. This shall be stated by X-marking and corresponding conditions in the certificate. Note: Based on the HOTL-decision according to item 4 (Decision 6.1) in the Minutes of the 50 th meeting of HOTL (16-18 October 1996). 1 Current wording relates to 76/117/EEC, may be superseded This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. G:\ARCHIV\EG-Sekretariate\Explosionsschutz\Allgemeines\Entzippt\ExNB00-54CS.DOC

46 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Page 1 of 1 European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/00/055/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL Date: Step*5.2.3 Initial proposal Proposer: Date: Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Subject: Cables ends or cables between parts of apparatus for types of protection other than intrinsic safety Authorised by Chairman: M. Shearman Date: Date of application: Signature: M D Shearman Question: For apparatus with type of protection other than intrinsic safety with cable ends or cables between parts of such apparatus, what shall be verified? Answer: The following shall be verified: - - requirements or tests in the standard regarding dielectric strength - cables entering enclosures through compression glands shall have correct size for the gland. - cables entering d enclosures shall be effectively filled. - Where appropriate the following may be covered by special conditions for safe use and installation (X-marking) 1. The cable shall be installed in a way which provides for mechanical protection 2. The cables shall be suitable for the environmental use Note: Requirements, which shall not be applied or considered include: Cable length Conductor Area (except when relevant to temperature classification) Fire Propagation Properties 1 Current wording relates to 76/117/EEC, may be superseded This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. G:\ARCHIV\EG-Sekretariate\Explosionsschutz\Allgemeines\Entzippt\ExNB00-55CS.DOC

47 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Page 1 of 1 European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/00/056/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL Date: Step*5.2.3 Initial proposal Proposer: Date: Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Subject: EN 50018:1977 Clause 3 and EN 50018:1994 Clause 14, Frequency Converters and EEx d Motors Authorised by Chairman: M. Shearman Date: Date of application: Signature: M D Shearman Question: What shall be verified if an EEx d motor is energised through a frequency converter? Answer: The following shall be verified: - temperature rise of the motor in combination with the converter. - thermal protection is provided in or on the motor windings. Note: thermal protection in or on the motor winding is not necessary if the converter is specified and included in the certificate. - In all cases the protection efficiency means shall be tested. 1 Current wording relates to 76/117/EEC, may be superseded This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. G:\ARCHIV\EG-Sekretariate\Explosionsschutz\Allgemeines\Entzippt\ExNB00-56CS.DOC

48

49

50

51

52

53

54

55 ExNB Co-ordination of Notified Bodies Electrical Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Issued: European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/98/066/CS rev.1 Editon 1.0 Original in English Status: Step*5.2.1 Question Originator HOTL(96)SP/006 Date: Step*5.2.3 Initial proposal Proposer: 2nd ExNB Meeting Date: Step*5.2.4 Responses/Final Draft 5 th ExNB meeting Date: 14/06/20 01 *Step refers to ExNB Rules 1 st amendment Date: 09/09/02 Subject: Directive, 94/9/EC Article No. Directive, ESR No. Directive, Module Annex No. Standard, No. EN 50020:1994 sub-clause and Verification of CTI for 'i' Authorised by Chairman: M. Shearman Date: 09/09/02 Date of application: Signature: Subject: Question 1: Answer: Question 2: EN 50020:1994 sub-clause and Verification of CTI for 'i' How shall CTI for PCBs, with creepage distances on which intrinsic safety depends, be verified? By making own CTI measurements or measurements by a sub-contracted laboratory or accept CTI values provided by the apparatus manufacturer backed up with evidence of quality assured measurement (e.g. accredited test report) according to the correct test procedure (IEC 60112:1979). CTI values together with a reference to the correct test procedure (IEC 60112:1979) specified in the documentation by the apparatus manufacturer or manufacturer of the PCB, can also be accepted if backed up by experience of the laboratory. For which cases shall CTI be verified for coated PCBs? Answer: CTI shall be verified for both coated and uncoated PCB, irrespective of if conductive parts protrude through the coating or not. This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. ExNB98-066rev1CS EN sub-clause and Verification of CTI for 'i'.doc

56 - 2 - However, for PCBs with coating according to sub-clause and with no conductors emerging from the coating (including no conductive parts with sharp edges), CTI need not to be verified for neither coated nor uncoated samples of the PCB. ExNB98-066rev1CS EN sub-clause and Verification of CTI for 'i'.doc

57

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75

76

77

78

79

80

81

82

83

84

85

86

87

88

89

90

91

92

93

94

95

96

97

98

99

100

101

102

103

104

105

106

107

108

109

110

111

112

113

114

115

116

117

118

119

120

121

122

123

124

125

126

127

128

129

130

131 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Issued: European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/02/111/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator WG/98/9 Date: 16/02/01 Step*5.2.3 Initial proposal Proposer: WG/98/9 Date: 16/02/01 Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Subject: Directive, 94/9/EC Article No. Directive, ESR No. Directive, Module Annex No. Standard, No. 94/9/EC Annex Authorised by Chairman: M. Shearman Date: 18/06/03 Date of application: Signature: Equipment with connections between areas covered by directive 94/9/EC and areas with high pressure Question: Does conveying equipment where some parts but not all are under atmospheric pressure with internal pressures different from atmospheric pressure fall under the scope of directive 94/9/EC and should the assessment of the equipment take into account the increasing hazards associated with these other pressures? Answer: Yes. Since conveying equipment is covered by the Directive 98/37/EC for machinery, a risk assessment has to be performed including the risk of explosion independent of the question whether the equipment is matter of Directive 94/9/EC. When performing this risk assessment it will become evident that although parts of the described equipment are outside the scope of Directive 94/9/EC during normal operation (pressure oscillates between too low and too high values in relation to "atmospheric conditions") some parts or spaces still are under the scope and that the whole equipment during start and shut down is under the scope, at least. So both of the following examples fall under the scope of Directive 94/9/EC. This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. EXNB02-111CS Equipment with connections between areas covered by directive 94-9-EC and areas with high pressure.doc

132 - 2 - ANNEX Examples: 1. Vapour recovery pump for petrol stations The pump is sucking the petrol vapour air mixture from the atmosphere and is conveying it into a zone 0 pipe. Accordingly it is connected at its inlet and outlet to a potentially explosive atmosphere. It is itself placed in a zone 1 environment. Accordingly all outer parts of the pump are connected to a hazardous area. It is the aim of all the protections measures of the pump to avoid the ignition of all connected hazardous areas, no matter if the ignition sources are inside or outside the pump. 2. Vacuum pump sucking from a vacuum container and conveying the mixture into a pressure vessel or pressure line In this case the inner parts of the pump are not connected to an atmospheric environment, and accordingly only the outer parts of the pump are covered by both ATEX regulations. (The manufacturer may wish to sell this equipment for atmospheric use of the inlet and outlet side additionally, and then case 1 applies). EXNB02-111CS Equipment with connections between areas covered by directive 94-9-EC and areas with high pressure.doc

133 ExNB Co-ordination of Notified Bodies Equipment for use in potentially explosive atmospheres on Council Directive 94/9/EC (ATEX) Issued: European ATEX Notified Bodies Group Clarification/Decision Sheet N ExNB/02/112/CS Editon 1.0 Original in English Status: Step*5.2.1 Question Originator WG/98/5 Date: 15/05/01 Step*5.2.3 Initial proposal Proposer: WG/98/5 Date: 15/05/01 Step*5.2.4 Responses/Final Draft Date: *Step refers to ExNB Rules Authorised by Chairman: M. Shearman Date: 18/06/03 Date of application: Signature: EC-type examination of gas detectors incorporating a measuring function for explosion protection Question: When does Annex II, Clause 1.5 of directive 94/9/EC apply if performing EC Type examination of gas detectors that incorporate a measuring function for explosion protection? Answer: If a gas detector incorporates a measuring function for explosion protection in the sense of directive 94/9/EC it shall be assessed as safety-related device according to annex II, clause 1.5 EOTC/01/009 also applies. For example, a portable gas detector that is intended to be used to detect the presence of an explosive atmosphere prior to the opening of a flameproof enclosure that contains energised electrical circuits, is being used as a safety-related device. Annex 8, question 12 of the ATEX-guidelines concludes that: 1. Measuring equipment is within the scope. 2. Measuring equipment has to be safe with respect to explosion protection and the measuring function also requires assessment. 3. This measuring function can be used for the evaluation of potentially explosive atmospheres or for control of ignition sources within the equipment itself. This ExNB Interpretation/Clarification Sheet has the sole purpose of clarifying the application of the EN Standards and/or of the requirements of Directive 94/9/EC and related documents. It does not in any way change the content of the standards and/or of the requirements. It remains valid until an official answer is received from the European Commission of the relevant standardization bodies. EXNB02-112CS EC-type examination of gas detectors incorporating a measuring function for explosion protection.doc

ATEX/05/1/7. In detail:

ATEX/05/1/7. In detail: ATEX/05/1/7 This paper contains available and signed ExNBG clarification sheets and is subdivided in 4 sections. Please be aware that this item will require a large part of the time available for the meeting.

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 17065:2012 to provide product conformity certification Newport Business Park New Port Road Ellesmere Port CH65 4LZ United Kingdom Contact:

More information

Report on the activities of the ATEX consultant. Xavier Lefebvre. Contract : CENELEC/NA Consultant/2013-1

Report on the activities of the ATEX consultant. Xavier Lefebvre. Contract : CENELEC/NA Consultant/2013-1 Report on the activities of the ATEX consultant Xavier Lefebvre Contract : CENELEC/NA Consultant/2013-1 Period covered: from 1 January 2013 to 1 July 2013 1. Attended meetings Date Subject Location 2013.01.28

More information

EQUIPMENT INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

EQUIPMENT INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) English European Commission > Enterprise & Industry > Industry Sectors > Equipment intended for use in Potentially Explosive Atmospheres (ATEX) > How to apply the Directive > Contact Search Considerations

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 17065:2012 to provide product conformity certification Unit 16-18 Abenbury Way Wrexham Industrial Estate Wrexham LL13 9UZ United Kingdom Contact:

More information

Survey of electrical equipment installed in hazardous areas on tankers

Survey of electrical equipment installed in hazardous areas on tankers (June 2015) Survey of electrical equipment installed in hazardous areas on tankers 1. Application The recommendations in this document apply for survey of electrical installation in hazardous areas on

More information

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US. Flexible Schedule of Accreditation SIRA CERTIFICATION SERVICE. Issue No: 63A Issue date 16 th June 2015 Unit 6 Hawarden Industrial Park Hawarden, CH5 3US, United Kingdom Contact: Mr A Myler Tel: +44 (0)1244

More information

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US. Flexible Schedule of Accreditation SIRA CERTIFICATION SERVICE. Issue No: 072A Issue date 23 rd March 2018 Unit 6 Hawarden Industrial Park Hawarden, CH5 3US, United Kingdom Contact: Mr A Myler Tel: +44

More information

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC Quick Introduction to TÛV Denmark TÜV Denmark - is a part of the TÜV NORD Group a global Organisation f Certification and Inspection of: Quality Management Systems, Products, Processes and Qualification

More information

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements ExTR Reference Number...: ExTR Free Reference Number...: 223531 Compiled by + signature (ExTL)...: Reviewed by + signature (ExTL)...: NO/NEM/ExTR12.0018/00 Stig André Norheim Arne Hortman Date of issue...:

More information

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining The Laboratory is qualified to update standards identifying the test procedures. The laboratory requires/applies a flexible scope of accreditation permitted as detailed in the Annex. Updated list of activities

More information

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 PPE-R/00.017 Version 2 RECOMMENDATION FOR USE Number of pages: 5 Approval stage : Approved on : Origin : Horizontal Committee, C2D Ad hoc group

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60079-0 Edition 3.1 2000-06 Edition 3:1998 consolidated with amendment 1:2000 Electrical apparatus for explosive gas atmospheres Part 0: General requirements IEC 2000 Copyright

More information

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS The ATEX Directive consists of two EU Directives, ATEX Directive 2014/34/EU and ATEX Directive 99/92/EC. ATEX Directive 2014/34/EU embodies the European minimum

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK SIRA Certification Service Accredited to ISO/IEC 17065:2012 to provide product conformity Unit 6 Hawarden Industrial Park Hawarden Deeside

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity Certificate of Conformity: IECEx SIR 09.0111 http://iecex.iec.ch/iecex/iecexweb.nsf/fc034777969a786bc1256d42005bd791/f076962... Page 1 of 3 22/01/2010 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL

More information

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor Report No. 3040249EC FM Approvals Ltd 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT Product: Model and/or Type Reference: Flame Detector IPES-IR3 Description of the Product:

More information

BUSINESS PLAN CEN/TC 305 POTENTIALLY EXPLOSIVE ATMOSPHERES EXPLOSION PREVENTION AND PROTECTION EXECUTIVE SUMMARY

BUSINESS PLAN CEN/TC 305 POTENTIALLY EXPLOSIVE ATMOSPHERES EXPLOSION PREVENTION AND PROTECTION EXECUTIVE SUMMARY BUSINESS PLAN CEN/TC 305 POTENTIALLY EXPLOSIVE ATMOSPHERES EXPLOSION PREVENTION AND PROTECTION CEN/TC 305 Business Plan Page: 1 Business environment, benefits and priorities EXECUTIVE SUMMARY CEN/TC 305

More information

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations)

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations) Annex II Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations) 1. According to Recommendation L, market surveillance should be included as a flanking area of

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60079-1 Fourth edition 2001-02 Electrical apparatus for explosive gas atmospheres Part 1: Flameproof enclosures "d" Matériel électrique pour atmosphères explosives gazeuses Partie

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 60079.0:2012 IEC 60079-0, Ed. 6.0 (2011) AS/NZS 60079.0:2012 Australian/New Zealand Standard Explosive atmospheres Part 0: Equipment General requirements AS/NZS 60079.0:2012 This Joint Australian/New

More information

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or

More information

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION 8.4.2016 EN Official Journal of the European Union C 126/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework

More information

(German speaking trainers with English written slides)

(German speaking trainers with English written slides) Kiwa organizes dedicated training courses in Germany (Hannover, Kaufbeuren) especially for German manufacturers and at Kiwa in Apeldoorn, The Netherlands. Language spoken is German and English (German

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate IECEx

More information

Training, Assessment, Consultants for Hazardous & Industrial Areas

Training, Assessment, Consultants for Hazardous & Industrial Areas Training, Assessment, Consultants for Hazardous & Industrial Areas EPIT provides specialist training, assessment and consultancy services for engineers working in hazardous and industrial environments.

More information

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear IEC/PAS 62271-109 Edition 1.0 2002-07 High-voltage switchgear and controlgear Part 109: Alternating-current series capacitor by-pass switches PUBLICLY AVAILABLE SPECIFICATION INTERNATIONAL ELECTROTECHNICAL

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU GENERAL The accidental ignition of an atmosphere containing a large quantity of gas, vapour, mists and/or dust may cause an explosion. Specific

More information

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION 8.9.2017 EN Official Journal of the European Union C 298/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework

More information

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2 Flammable gases Detectors Model DAX 03F DAX 03F- C DAX 03F- H Note for installation, use and maintenance Version 1.2 Introduction This handbook must be read carefully by any person who has or will have

More information

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc User manual Explosion-safe window air conditioning system Type series AR-054 II 3 G Ex ic nac h IIC T3 Gc 1. Safety Instructions The window air conditioning series AR-054 is an explosion-safe product suitable

More information

EUROPUMP ATEX Guideline Part II

EUROPUMP ATEX Guideline Part II EUROPEAN ASSOCIATION OF PUMP MANUFACTURERS ASSOCIATION EUROPÉENNE DES CONSTRUCTEURS DE POMPES EUROPÄISCHE VEREINIGUNG DER PUMPENHERSTELLER EUROPUMP ATEX Guideline Part II Application of the EC-Guidelines

More information

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas Page 1 of 5 Title Install fixed gas detection apparatus in hazardous areas Level 4 Credits 2 Purpose This unit standard covers the installation, calibration, and response checking of fixed gas detection

More information

VERSAFLOW VORTEX Supplementary instructions

VERSAFLOW VORTEX Supplementary instructions VERSAFLOW VORTEX Supplementary instructions Vortex flowmeter Equipment category II 2G CONTENTS VERSAFLOW VORTEX 1 Safety instructions 3 1.1 General notes... 3 1.2 EC conformity... 3 1.3 Approval according

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60

More information

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 335/02)

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 335/02) C 335/10 EN Official Journal of the European Union 9.10.2015 Commission communication in the framework of the implementation of Directive 94/9/EC of the European Parliament and of the Council of 23 March

More information

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY ("Official Gazette of RS, issue No. 13/2010) I INTRODUCTION Scope Article 1 This Rulebook stipulates the essential requirements that shall be met with regard to

More information

AS/NZS :2015. Explosive atmospheres AS/NZS :2015. Part 1: Equipment protection by flameproof enclosures d

AS/NZS :2015. Explosive atmospheres AS/NZS :2015. Part 1: Equipment protection by flameproof enclosures d AS/NZS 60079.1:2015 (IEC 60079-1 Ed.7.0:2015, IDT) Australian/New Zealand Standard Explosive atmospheres Part 1: Equipment protection by flameproof enclosures d Superseding AS/NZS 60079.1:2007 AS/NZS 60079.1:2015

More information

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,

More information

GENERAL SPECIFICATION ELECTRICAL

GENERAL SPECIFICATION ELECTRICAL GENERAL SPECIFICATION ELECTRICAL GS ELE 331 Tape trace heating 00 10/04 First issue Rev. Date Notes Contents 1. Scope...3 2. Reference documents...3 3. Environmental Conditions...4 4. Technical Requirements...5

More information

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2 Compliance with EN60079-15: 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2 RJ11FTVX series: rugged and sealed RJ11/12 connectors Report Prepared by : Amphenol Socapex

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:2 Status: Current Certificate history:

More information

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS... TITLE SPECIFICATION FOR PHOTOELECTRIC CONTROL UNITS (PECUs) REFERENCE REV DATE: JUNE 2017 PAGE: 1 OF 16 REVISION DATE: Table of Contents FOREWORD... 3 INTRODUCTION... 4 1 SCOPE... 4 2 NORMATIVE REFERENCES...

More information

HazLoc Essential Guides:

HazLoc Essential Guides: HazLoc Essential Guides: Intertek Deeside Lane, Chester, CH1 6DD UK hazloc@intertek.com 01244 882590 www.intertek-hazloc.com Introduction This white paper aims to clarify ATEX Technical Files. As a Notified

More information

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2016/C 126/02)

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2016/C 126/02) 8.4.2016 EN Official Journal of the European Union C 126/13 Commission communication in the framework of the implementation of Directive 2014/34/EU of the European Parliament and of the Council on the

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...

More information

Apparatus Groups are sometimes referred to, erroneously, as Gas Groups.

Apparatus Groups are sometimes referred to, erroneously, as Gas Groups. ATEX Jargon Buster ABB s ATEX jargon buster explains the terminology users are likely to encounter when purchasing equipment for hazardous areas. If you have a specific ATEX question, please send an email

More information

INTERNATIONAL STANDARD NORME INTERNATIONALE

INTERNATIONAL STANDARD NORME INTERNATIONALE IEC 62031 INTERNATIONAL STANDARD NORME INTERNATIONALE Edition 1.0 2008-01 2 62031 IEC:2008 CONTENTS FOREWORD...3 INTRODUCTION...5 1 Scope...6 2 Normative references...6 3 Terms and definitions...7 4 General

More information

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE DANISH TECHNOLOGICAL INSTITUTE The Danish Technological Institute is a self-owned and not-f-profit institution. We develop, apply and disseminate research- and technologically-based knowledge f the Danish

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

C 319/6 Official Journal of the European Union

C 319/6 Official Journal of the European Union C 319/6 Official Journal of the European Union 5.11.2013 Commission communication in the framework of the implementation of the Directive 94/9/EC of the European Parliament and the Council of 23 March

More information

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES. ET 105:2001 (Second Edition)

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES. ET 105:2001 (Second Edition) NATIONAL RULES FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES ET 105:2001 (Second Edition) Consolidated Amendments, Corrigenda and Errata 01/2010 Introduction When ET 105:2001 was originally

More information

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2018/C 092/02)

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2018/C 092/02) 9.3.2018 EN Official Journal of the European Union C 92/87 Commission communication in the framework of the implementation of Directive 2014/34/EU of the European Parliament and of the Council on the harmonisation

More information

CONSULTING Training Courses

CONSULTING Training Courses CONSULTING Training Courses 2 EXPLOLABS TRAINING MAKES THE DIFFERENCE 1. GENERAL Why training by Explolabs Consulting? For training in the specialized, high-risk field of explosion protection, one needs

More information

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER INSTRUCTIONS FOR SAFE OPERATIONS LM000 EXPLOSION PROOF LASER DISTANCE METER www.cord-ex.com CONTENTS READ THIS FIRST Read This First Liability Trademark Information Product Information Special Conditions

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further. ATEX SOLUTIONS In order to apply a single level for health and safety requirements and to overcome barriers of trade within Europe, national regulations for explosion prevention were harmonized in 1975

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60335-2-69 Edition 3.1 2005-01 Edition 3:2002 consolidated with amendment 1:2004 Household and similar electrical appliances Safety Part 2-69: Particular requirements for wet

More information

DIRECTIVE 2014/34/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL

DIRECTIVE 2014/34/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL 29.3.2014 Official Journal of the European Union L 96/309 DIRECTIVE 2014/34/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February 2014 on the harmonisation of the laws of the Member States relating

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBG15E and BExBG10E Flameproof / Increased Safety Xenon Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG15E and BExBG10E beacons are flameproof

More information

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres Quick Introduction to: DANISH TECHNOLOGICAL INSTITUTE The Danish Technological Institute is a self-owned and not-fprofit institution. We develop, apply and disseminate research- and technologically-based

More information

Approval of Ex (Electrical) Equipment for use/installation in Hazardous Areas.

Approval of Ex (Electrical) Equipment for use/installation in Hazardous Areas. Approval of Ex (Electrical) Equipment for use/installation in Hazardous Areas. Requirement under Rule 102 of the Petroleum Rules, 2002 lays down that no electrical wiring shall be installed and no electrical

More information

1. GENERAL TECHNICAL INFORMATION

1. GENERAL TECHNICAL INFORMATION 1. GENERAL TECHNICAL INFORMATION 1.1 EXPLOSIVE ATMOSPHERES: Every time that dangerous quantities and concentration of flammable gas, vapors mixture or dust clouds exists, risk of explosions may arise.

More information

GUIDELINES. the Interpretation of

GUIDELINES. the Interpretation of GUIDELINES on the Interpretation of ATEX Directive Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Directive 94/9/EC for the Valve and Actuator Industry prepared

More information

SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series

SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series Pag. 1/6 Enclosure for asynchronous electric motors Series LEX 80,90,100,112,132,160,180,200,225,250,280,315 and 355 Ex na, Ex td execution II 3G, II 2D SAFETY INSTRUCTIONS euromotori motori elettrici

More information

AS/NZS 3820:2009 (Incorporating Amendment 1) Essential safety requirements for electrical equipment

AS/NZS 3820:2009 (Incorporating Amendment 1) Essential safety requirements for electrical equipment AS/NZS 3820:2009 (Incorporating Amendment 1) Essential safety requirements for electrical equipment AS/NZS 3820:2009 This Joint Australian/New Zealand Standard was prepared by Joint Technical Committee

More information

Lloyd s Register Type Approval System Test Specification Number 3

Lloyd s Register Type Approval System Test Specification Number 3 Working together for a safer world Lloyd s Register Type Approval System Test Specification Number 3 July 2015 Performance Test Specification for Equipment to be used in Marine Applications: Electric Cables

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:2 Status: Current Date of Issue: 2014-05-14

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

Guidance from the Group of Notified Bodies for the Construction Products Directive 89/106/EEC

Guidance from the Group of Notified Bodies for the Construction Products Directive 89/106/EEC CEN/TC 88 N 2873 GNB-CPD SG19 Guidance from the Group of Notified Bodies for the Construction Products Directive 89/106/EEC NB-CPD/SG19/11/085 Issued: 19 October 2011 APPROVED - GUIDANCE GNB-CPD position

More information

Gas Appliances Directive - Advisory Committee. Comité Consultatif de la Directive Appareils a Gaz

Gas Appliances Directive - Advisory Committee. Comité Consultatif de la Directive Appareils a Gaz Document GAD-AC N 519 E v2 Date 2016-11 23 Gas Appliances Directive - Advisory Committee Comité Consultatif de la Directive Appareils a Gaz FOR INFORMATION CONCERNING: Questions and Answers approved by

More information

AS/NZS :2003 Luminaires - Part 1: General requirements and tests

AS/NZS :2003 Luminaires - Part 1: General requirements and tests Menu Home About this portal Latest updates Print Save Email Resource detail Citations AS/NZS 60598.1:2003 Luminaires - Part 1: General requirements and tests Table of Contents View on Information Provider

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT

More information

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm 0102 Model Number Features 4 mm non-flush Accessories BF 12 Mounting flange, 12 mm Technical Data specifications Switching element function NAMUR, NO Rated operating distance s n 4 mm Installation non-flush

More information

Do you manufacture equipment or protective systems for use in potentially explosive atmospheres? Do you process, trade or import them?

Do you manufacture equipment or protective systems for use in potentially explosive atmospheres? Do you process, trade or import them? TÜV NORD CERT GmbH Geschäftsstelle Hannover Am TÜV 1 30519 Hannover Zertifizierung Certification body for equipment according to Directive 94/9/EC of TÜV NORD CERT GmbH Summarized Information Directive

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-nA Edition 08/207 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

Council Directive 93/68/EEC of 22 July 1993 amending Directives

Council Directive 93/68/EEC of 22 July 1993 amending Directives Council Directive 93/68/EEC of 22 July 1993 amending Directives 87/404/EEC (simple pressure vessels), 88/378/EEC (safety of toys), 89/106/EEC (construction products), 89/336/EEC (electromagnetic compatibility),

More information

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group Pressure D. EVALUATION ASSESSMENT PROCEDURES Guideline D-01 Guideline related to: Annex III, module G Is design approval by a notified body required under module G? Module G does not explicitly require formal design

More information

AS/NZS :2015

AS/NZS :2015 AS/NZS 60598.2.10:2015 (IEC 60598.2.10, Ed.2.0:2003, MOD) Australian/New Zealand Standard Luminaires Part 2.10: Particular requirements Portable luminaires for children Superseding AS/NZS 60598.2.10:1998

More information

Electrical Installations Design, Selection, Erection and Inspection

Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2018 Jakarta, Indonesia Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2018 Jakarta, Indonesia Peter Thurnherr thuba Ltd.,

More information

Valve Manufacturers Association of America

Valve Manufacturers Association of America BUSINESS ASSURANCE Valve Manufacturers Association of America 2016 Technical Seminar: EU s New Legislation Framework (NLF) - What this means to you. Mike Norman 1 VMA Technical Session - March 2016 SAFER,

More information

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing

More information

Approval Standard for Electric Equipment for use in Hazardous (Classified) Locations General Requirements

Approval Standard for Electric Equipment for use in Hazardous (Classified) Locations General Requirements Approval Standard for Electric Equipment for use in Hazardous (Classified) Locations General Requirements Class Number 3600 November 1998 2002 FM Approvals LLC. All rights reserved. Foreword FM Approvals

More information

Requirements for ships carrying hydrogen and compressed natural gas vehicles

Requirements for ships carrying hydrogen and compressed natural gas vehicles Lloyd's Register briefing IMO FP 55 Summary report for clients Overview The 55 th session of the IMO Fire Protection Sub Committee (FP) was held from 25 th to 29 th July 2011, at the IMO headquarters in

More information

Compilation of regulatory approaches used in various countries. Information received by the Secretariat through a survey in 2009

Compilation of regulatory approaches used in various countries. Information received by the Secretariat through a survey in 2009 Compilation of regulatory approaches used in various countries Information received by the Secretariat through a survey in 2009 At its seventeenth session, the Working Party mandated the Sectoral Initiative

More information

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA - TF N 530 Rev.2 2012-04-13 CONSTRUCTION SECTOR STANDARDIZATION GUIDANCE DOCUMENT Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA - 1 Drafting

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following

More information

Leading the world in explosion protection

Leading the world in explosion protection Leading the world in explosion protection Introducing the experts in flame and explosion protection Welcome to Elmac Technologies, the technical leaders in flame and explosion protection systems for use

More information

User s Manual YTA610 and YTA710 NEPSI Certification

User s Manual YTA610 and YTA710 NEPSI Certification User s Manual YTA60 and YTA70 NEPSI Certification [Option code: /NS, /NS5 and /NF] st Edition . INTRODUCTION Thank you for purchasing the YTA60 and YTA70 Temperature transmitters. This manual contains

More information

The New EMC Directive 2004/108/EC

The New EMC Directive 2004/108/EC The New EMC Directive 2004/108/EC In the process of this review I have tried to spell out in words what is often referred to as a section number while also keeping to location information as used in the

More information

Transition from GAD to the GAR July,

Transition from GAD to the GAR July, Transition from GAD to the GAR July, 6 2017 1 P a g e Introduction Dear Sit Customers, As of 21 April 2018, the Gas Appliances Directive 2009/142/EC (GAD) will be replaced by the new Gas Appliances Regulation

More information

Official Journal of the European Union

Official Journal of the European Union C 20/16 27.1.2009 Commission communication in the framework of the implementation of the Directive 94/9/EC of the European Parliament and the Council on the approximation of the laws of the Member States

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 50 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 50 mm Installation non-flush Output polarity NAMUR

More information

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3. Rev. 1 03/05/2015 ANNEX A to the Yokogawa Corporation of America Quality Assurance Manual For Additional Requirements selectively applied to ATEX and IECEx certified products CONTENTS 1. Scope 2. Purpose

More information

ECE/TRANS/WP.15/AC.2/2018/11

ECE/TRANS/WP.15/AC.2/2018/11 United Nations Economic and Social Council ECE/TRANS/WP.15/AC.2/2018/11 Distr.: General 20 October 2017 English Original: French Economic Commission for Europe Inland Transport Committee Working Party

More information

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE)

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE) SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE) SCS/SF/053-8 Issue 1 Sira Certification Service INTRODUCTION One of the conditions placed on all holders of Sira

More information

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC By: Helge Knudsen, Test&Approval, Niros Telecommunication A/S You may have heard those expressions concerning Transceivers and other electric equipment